• Control Mode: V/F control; Open-loop vector
control
• Carrier frequency up to 15KHz
• Auto torque boost and auto slip compensation
function
• Built-in PID control
• Standard equiped Modbus (RS485 baud rate up
to 38400bps)
• Sleep/wake up funtion
L011452
The FV100-2T is a rugged line of AC Variable Frequency Drives for OEM and Industrial
applications, combining high performance and cost efciency into one powerful package.
Available in input voltages of 240VAC and capable of powering AC motors from 0.50
to 30Hp, these VFDs are great for normal duty and soft-start operation. These drives
provide energy savings and increased efciency, making them ideal for fan, pump,
and HVAC applications. They are equipped with a number of different features such as
momentary power loss restarts, ying starts, auto-acceleration/deceleration, and
sensorless vector control. These features make the VFDs compatible with most AC
motors and allow for exibility within an application.
FEATURES
KNC-VFD-FV100-2T Series
910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com
SERIES # Input Voltage
Range
Max
Power
(KW)
Max
Power
(HP)
Rated
Current
(A)
Overload Tolerance
for One Minute
(A)
Installation
Type
FV100-2T-0004G 3-Phase,
240V
0.40 0.5 2.5 3.75 Cabinet or
Enclosure
FV100-2T-0007G 3-Phase,
240V
0.75 1 4.0 6 Cabinet or
Enclosure
FV100-2T-0015G 3-Phase,
240V
1.5 2 7.5 11.25 Cabinet or
Enclosure
FV100-2T-0022G 3-Phase,
240V
2.2 3 10 15 Cabinet or
Enclosure
FV100-2T-0037G 3-Phase,
240V
3.7 5 16 24 Cabinet or
Enclosure
FV100-2T-0055G 3-Phase,
240V
5.5 7.5 24.5 37 Cabinet or
Enclosure
FV100-2T-0075G 3-Phase,
240V
7.5 10 30 45 Cabinet or
Enclosure
FV100-2T-0110G 3-Phase,
240V
11 15 42 63 Cabinet or
Enclosure
FV100-2T-0150G 3-Phase.
240V
15 20 55 82.5 Cabinet or
Enclosure
FV100-2T-0185G 3-Phase.
240V
18.5 25 70 105 Cabinet or
Enclosure
FV100-2T-0220G 3-Phase,
240V
22 30 80 120 Cabinet or
Enclosure
L011452
SPECIFICATIONS
KNC-VFD-FV100-2T Series
Item W W1 H H1 D D1 T1
FV100-2T-0004G 115 106 185 176 171 65 7
FV100-2T-0007G 115 106 185 176 171 65 7
FV100-2T-0015G 115 106 185 176 171 65 7
FV100-2T-0022G 115 106 185 176 171 65 7
FV100-2T-0037G 115 106 185 176 171 65 7
FV100-2T-0055G 165 110 274 264 193 - 2
FV100-2T-0075G 165 110 274 264 193 - 2
FV100-2T-0110G 194 120 324 312 197 - 2
FV100-2T-0150G 297 200 451 433 224 89 3
FV100-2T-0185G 297 200 451 433 224 89 3
FV100-2T-0220G 297 200 451 433 224 89 3
INPUT
Rated Voltage/Frequency 2T: 3-phase, 200-240VAC; 50Hz/60Hz
Allowable Voltage Range 2T: 180-260VAC; Voltage Unbalanceness:<3%; Frequency: ±5%
OUTPUT
Voltage 380~Rated Input Voltage
Frequency 0Hz-300Hz (0Hz-1000Hz Custom)
Overload Capacity G Type: 150% Rated Current for 1 Minute, 180% Rated Current for 10 Seconds
MAIN CONTROL CHARACTERISTICS
Control Method Vector Control Without PG, V/F Control
Starting Torque 0.5Hz: 150% Rated Torque (Vector Control Without PG)
Frequency Accuracy Digital Setting: Max. Frequency x ±0.01%; Analog Setting: Max. Frequency x ±0.2%
Frequency Resolution Digital Setting: 0.01Hz; Analog Setting: Max. Frequency x 0.05%
Torque Boost Manual Torque Boost: 0%-30.0%
V/F Pattern 4 Patterns: 1 V/F Curve Mode Set by User and 3 Kinds of Torque-Derating Modes
(2.0 Power, 1.7 Power, 1.2 Power)
Acceleration/Deceleration
Curve
Linear Acceleration/Deceleration. Four Kinds of Acceleration/Deceleration Time
Auto Current Limit Limit Current During Operation Automatically to Prevent Frequent Overcurrent Trip
CUSTOMIZED FUNCTION
Operation Command Keypad Setting, Terminal Setting, Communication Setting
Frequency Command Digital Setting, Analog Voltage Setting, Analog Current Setting
Auxiliary Frequency Setting Implement Flexible Auxiliary Frequency Trim and Frequency Synthesis
Analog Output 1 Channel Analog Output (0/4~20mA or 0/2~10V)
Protection Function Overcurrent Protection, Overvoltage Protection, Undervoltage Protection, Overheat
Protection, Overload Protection, Missing Phase Protection (Selectable) and So On
ENVIRONMENT
Altitude Derated Above 1000m, The Rated Output Current Shall be Decreased by 10% for
Every Rise of 1000m
Ambient Temperature -10°C~ + 40°C (Derated at 40°C~50°C)
Humidity 5%~95%RH, Non-Condensing
Vibration Less Than 5.9m/s2 (0.6g)
Storage Temperature -40°C~ + 70°C
TECHNICAL SPECIFICATIONS
910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com
L011452
KNC-VFD-FV100-2T Series
KNC-VFD-FV100-2T Series
WIRING DIAGRAM
910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com
L011452
MODEL FV100-2T
0004 0007 0015 0022 0037 0055 0075 0110 0150 0185 0220
The Power of Suitable
Motor (KW)
0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22
OUTPUT
Voltage (V) 3-Phase, 0~ Rated Input Voltage
Rate Output Current (A) 2.5 4.0 7.5 10 16 24.5 30 42 55 70 80
Overload Capacity 150% 1 Minute; 180% 10 Seconds; 200% 0.5 Second; 10 Minutes Interval (Inverse
Time Limit Speciality)
INPUT
Rated Voltage/Frequency 3 Phase, 380V~440V AC; 50Hz/60Hz
Allowable Voltage Range 180V~260VAC; Voltage Unbalancedness:≤3%; Allowable Frequency Fluctuation; ± 5%
Rated Input Current (A) 3.2 6.3 9 15 22 30 35 43 56 71 81