M1TLK300&200010EN1

User Manual: M1TLK300&200010EN1

Open the PDF directly: View PDF PDF.
Page Count: 108 [warning: Documents this large are best viewed by clicking the View PDF Link!]

TLK300 & TLK2000
( /V1, /V2 , /V3 & /V4 )
USER MANUAL
VOLUME1
Manufactured by R.V.R ELETTRONICA S.p.A. Italy
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 ) - User Manual
Version 1.0
© Copyright 2014
R.V.R. Elettronica SpA
Via del Fonditore 2/2c - 40138 - Bologna (Italia)
Telephone: +39 051 6010506
Fax: +39 051 6011104
Email: info@rvr.it
Web: www.rvr.it
All rights reserved
Printed and bound in Italy. No part of this manual may be reproduced,
memorized or transmitted in any form or by any means, electronic
or mechanic, including photocopying, recording or by any informa-
tion storage and retrieval system, without written permission of the
copyright owner.
File Name: TLK300_2000_V1-V2-V3-V4_ING_1.0.indb
Version: 1.0
Date: 13/06/2014
Revision History
Date Version Reason Editor
13/06/2014 1.0 First Version J. H. Berti
Declaration of Conformity
Hereby, R.V.R. Elettronica SpA, declares that this FM transmitter is in
compliance with the essential requirements and other relevant provisions of
Directive 1999/5/EC.
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
i
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
Rev. 1.0 - 29/06/2013
We, the undersigned,
Manufacturer’s Name: R.V.R. Elettronica SpA
Manufacturer’s Address: Via del Fonditore 2/2c
Zona Ind. Roveri
40138 Bologna
Italy
Certify and declare under our sole responsibility that the product:
Product Description: Telemetry Unit
Models: TLK2000
Variants: TLK300
when used for its intended purpose, is in compliance with the essential re�uirements and
other relevant provisions of Directive 1999/5/CE “R&TTE”, and therefore carries the “CE” mark.
The conformity assessment procedure referred in Article 10 and detailed in Annex III of Directive
1999/5/EC has been followed.
The following harmonized standard have been applied:
ElectroMagnetic Compatibility (3.1b): EN 301 489-1 V1.9.2 (2011-09) +
EN 301 489-11 V1.3.1 (2006-05)
Safety (3.1a): EN 60215 (1997-10) +
EN 60065 (2011-01)
The technical documentation is held at the location above, as required by the conformity assessment
procedure.
Bologna, Italia, 20/06/2013
DECLARATION OF
CONFORMITY
Ravagnani Stefano
Direttore Tecnico
R.V.R. Elettronica S.p.A.
ii User Manual
Rev. 1.0 - 13/06/14
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
ELETTRONICA
Technical Description
TLK300 TLK2000
Parameters Conditions U.M. Value Notes
Ambient working temperature
°C
-10 to + 50 -10 to + 50 Whithout condensing
AC Power Input AC Supply Voltage
VAC
80 ÷ 260 (*) 80 ÷ 260 (*) (*) Full range (**) Internal switch
Active Power Consumption
W
25 25
Connector VDE IEC Standard VDE IEC Standard
DC Power Input DC Supply Voltage
VDC
12 12
DC Current
ADC
< 3 < 3 (*)max 25W (**) max 140W
FUSES
On Mains 1 External fuse F 1 A F - 5X20 mm 1 External fuse F 1 A F - 5X20 mm
Phisical Dimensions Front panel width
mm
483 (19") 483 (19") 19" EIA rack
Front panel height
mm
44 1HE 44 1HE
Overall depth
mm
263 263
Chassis depth
mm
239 239
Weigh
kg
about 4,3 about 4,9
Signalling LEDs Yes Yes
Display 40x2 Alphanumerical No Yes
Push buttons 4 (UP, DOWN , ENTER, ESC) No Yes
USB TELECON Protocol Yes Yes
RS232 TELECON Protocol Yes Yes
RS 485 PLUG-IN protocol Yes (only on WEB+GSM versions) Yes (only on WEB+GSM versions)
I
2
CYes Yes
RJ45 LAN Yes (only on WEB versions) Yes (only on WEB versions)
SIM slot & ANTENNA Yes (only on GSM versions) Yes (only on GSM versions)
VARIOUS
Cooling Convection cooling Convection cooling
Acoustic Noise
dBA
0 0
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
iii
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
Sommario
1. Preliminary Instructions 1
2. Warranty 1
3. First Aid 2
3.1 Treatment of electrical shocks 2
3.2 Treatment of electrical Burns 2
4. General Description 3
4.1 Unpacking 3
4.2 Features 3
4.3 Frontal Panel Description 5
4.4 Rear Panel Description 7
4.5 Connectors Description 9
5. Quick guide for installation and use 11
5.1 Preparation 11
5.2 Management Firmware 14
6. IdenticationandAccesstotheModules 21
6.1  IdenticationoftheModules 21
7. Working Principles 25
7.1 Panel card 25
7.2 Mainboard 25
7.3 16-bit CPU Card 25
7.4 USB Card 25
7.5 LAN Card 26
7.6 Alarm generation 26
8. Web User Interface (WUI) 28
8.1 Management Software 29
9. Versions with GSM 45
10. CongurationsofTransmitterSystem 47
 10.1 CongurationofTransmitterfromV1toV4Versions 47
11. SNMP Telemetry 91
11.1 MAIN MIB Description 91
11.1 SPECIFIC MIB Description 92
12. Connecting TLK to Internet network 98
iv User Manual
Rev. 1.0 - 13/06/14
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
ELETTRONICA
This page was intentionally left blank
1 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
1. Preliminary Instructions
• General foreword
The equipment in object is to considering for uses,
installation and maintenance from “trained” or “qualied”
staff, they conscious of the risks connected to operate
on electronic and electrical circuits electrical.
The “trained” definition means staff with technical
knowledge about the use of the equipment and with
responsibility regarding the own safety and the other
not qualified staff safety place under his directed
surveillance in case of works on the equipment.
The“qualied”denition means staffwith instruction and
experience about the use of the equipment and with
responsibility regarding the own safety and the other not
qualiedstaffsafetyplaceunderhisdirectedsurveillance
in case of works on the equipment.
WARNING: The machine can be e�uipped withWARNING: The machine can be e�uipped with The machine can be e�uipped withThe machine can be e�uipped with
an ON/OFF switch which could not remove completely
voltages inside the machine. It is necessary to
have disconnected the feeding cord, or to have
switched off the control panel, before to execute
technical operations, making sure himself that the
safety connection to ground is connected.
The technical interventions that expect the e�uipment
inspection with circuits under voltage must be carry out
fromtrainedand qualied staff in presence of a
second trained person that it is ready to intervene
removing voltage in case of need.
R.V.R. Elettronica SpA doesn’t assume responsibility for
injury or damage resulting from improper procedures or
practicesbyuntrained/unqualiedpersonnelinthehandling
of this unit.
WARNING: The e�uipment is not water resistant
and an infiltration could seriously compromise
its correct operation. In order to prevent fires or
electric shocks, do not expose the e�uipment to rain,
inltrationsorhumidity.
Pleaseobservealllocalcodesandreprotectionstandards
during installation and use of this unit.
WARNING: The e�uipment has to its inside
exposed parts to risk of electric shock, always
disconnect power before opening covers or removing
any part of this unit.
Fissures and holes are supplied for the ventilation in order
toassureareliableefcacyoftheproductthatforprotect
itselffromexcessiveheating, these ssures do nothave
tobeobstructedortobecovered.Thessuresdoesn’tbe
obstructed in no case. The product must not be incorporated
in a rack, unless it is supplied with a suitable ventilation or
that the manufacturer’s instructions are been followed.
WIRING: This euipment can irradiate radio
fre�uency energyand if it’s not installed following
the instructions contained in the manual and local
regulations it could generate interferences in radio
communications.
WIRING: This device has a connection to ground
on the power cord and on the chassis. Check that they
are correctly connected.
Operate with this device in a residential ambient can cause
radio disturbs; in this case, it can be demanded to the user
to take adequate measures.
Specications and informations contained in this manual
are furnished for information only, and are subject to change
at any time without notice, and should not be construed
as a commitment by R.V.R. Elettronica SpA.
The R.V.R. Elettronica SpA assumes no responsability or
liability for any errors or inaccuracies that may appear in
this manual, including the products and software described
in it;and it reserves the right to modify the design and/or
thetechnicalspecicationsoftheproductandthismanual
without notice.
Warning regarding the use designated and the use
limitations of the product.
This product is an transmitter radio indicated
for the audio broadcasting service in frequency
modulation. It uses working frequencies that are not
harmonized in the states of designated user.
The user of this product must obtain from the Authority
for spectrum management in the state of designated
user the appropriate authorization to use the radio
spectrum, before putting in exercise this equipment.
The working frequency, the transmitter power, let alone
otherspecicationsofthetransmissionsystemaresubject
tolimitationanddenitedintheauthorizationobtained.
2. Warranty
R.V.R. Electronics S.P.A. guarantees absence of
manufacturing defect and the good operation for the
products, within the provided terms and conditions.
Please read the terms carefully, because the purchase of
theproductoracceptanceoforderconrmation,constitutes
acceptance of the terms and conditions.
For the last legal terms and conditions, please visit our web
site (WWW.RVR.IT) wich may also be changed, removed
or updated for any reason without prior notice.
Warranty will be void in cases of opened products, physical
damage, misuse, modification, repair by unauthorised
persons, carelessness and using the product for other
purpose than its intended use.
In case of defect, proceed like described in the following:
1 Contact the dealer or distributor where you purchased
the unit. Describe the problem and, so that a possible
easy solution can be detected.
Dealers and Distributors are supplied with all the information
about problems that may occur and usually they can repair
the unit quicker than what the manufacturer could do. Very
often installing errors are discovered by dealers.
2 If your dealer cannot help you, contact R.V.R. Elettronica
and explain the problem. If it is decided to return the
unit to the factory, R.V.R. Elettronica will mail you a
regular authorization with all the necessary instructions
to send back the goods;
3 When you receive the authorization, you can return the
unit. Pack it carefully for the shipment, preferably using
the original packing and seal the package perfectly.
The customer always assumes the risks of loss (i.e.,
IMPORTANT
The symbol of lightning inside a triangle placed on the product, evidences the operations for
which is necessary gave it full attention to avoid risk of electric shocks.
The symbol of exclamation mark inside a triangle placed on the product, informs the user
about the presence of instructions inside the manual that accompanies the equipment, im-
portantfortheefcacyandthemaintenance(repairs).
2 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
R.V.R. is never responsible for damage or loss), until
the package reaches R.V.R. premises. For this reason,
we suggest you to insure the goods for the whole value.
Shipment must be effected C.I.F. (PREPAID) to the
addressspeciedbyR.V.R.’sservicemanageronthe
authorization
DO NOT RETURN UNITS WITHOUT OUR
AUTHORIZATION AS THEY WILL BE REFUSED
4 Be sure to enclose a written technical report where
mention all the problems found and a copy of your
original invoice establishing the starting date of the
warranty.
Replacement and warranty parts may be ordered from
the following address. Be sure to include the equipment
model and serial number as well as part description and
part number.
R.V.R. Elettronica SpA
Via del Fonditore, 2/2c
40138 BOLOGNA ITALY
Tel. +39 051 6010506
3. First Aid
The personnel employed in the installation, use and
maintenance of the device, shall be familiar with theory and
practiceofrstaid.
3.1 Treatment of electrical shocks
3.1.1 If the victim is not responsive
Follow the A-B-C’s of basic life support.
Place victim flat on his backon a hard
surface.
Open airway: lift up neck, push forehead back
(Figure 1).
Figure 1
clear out mouth if necessary and observe for
breathing
if not breathing, begin artificial breathing
(Figure 2): tilt head, pinch nostrils, make airtight
seal, four quick full breaths. Remember mouth
to mouth resuscitation must be commenced as
soon as possible.
Figure 2
Check carotid pulse (Figure 3); if pulse is
absent, begin articial circulation (Figure 4)
depressing sternum (Figure 5).
Figure 3 Figure 4
Figure 5
In case of only one rescuer, 15 compressions
alternated to two breaths.
If there are two rescuers, the rythm shall be of
one brath each 5 compressions.
Do not interrupt the rythm of compressions
when the second person is giving breath.
Call for medical assistance as soon as
possible.
3.1.2 If victim is responsive
Keep them warm.
Keep them as quiet as possible.
Loosen their clothing (a reclining position is
recommended).
Call for medical help as soon as possible.
3.2 Treatment of electrical Burns
3.2.1 Extensive burned and broken skin
Cover area with clean sheet or cloth.
Do not break blisters, remove tissue, remove
adhered particles of clothing, or apply any salve
or ointment.
Treat victim for shock as required.
Arrange transportation to a hospital as quickly
as possible.
If arms or legs are affected keep them
elevated.
If medical help will not be available within an hour and
the victim is conscious and not vomiting, give him a weak
solution of salt and soda: 1 level teaspoonful of salt and
1/2 level teaspoonful of baking soda to each quart of water
(neither hot or cold).
Allow victim to sip slowly about 4 ounces (half a glass) over
a period of 15 minutes.
Discontinueuidifvomitingoccurs.
DO NOT give alcohol.
3.2.2 Less severe burns
Apply cool (not ice cold) compresses using the
cleansed available cloth article.
Do not break blisters, remove tissue, remove
adhered particles of clothing, or apply salve or
ointment.
Apply clean dry dressing if necessary.
Treat victim for shock as required.
Arrange transportation to a hospital as quickly
as possible.
If arms or legs are affected keep them
elevated.
3 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
4. General Description
The TLK300 and the TLK2000, manufactured by R.V.R. Elettronica SpA, are
telemetry systems that allows an immediate intervention in case of fault, thanks
totheradiostationremotecontrol.Equipmentgreatexibilitymakesitpossible
to control a high number of devices or to modify the station layout. This operation
does not involve any radical changes of the control system, it is simply a matter
of adding expansion boards that will increase the number of operating parameters
the system can manage.
TLK300 and TLK2000 are designed to being contained into a 19” rack box of
1HE.
4.1 Unpacking
The package contains:
1 TLK300 or TLK2000
1 User Manual
1 Cavo di Alimentazione da Rete
The following accessories are also available from Your R.V.R. Dealer:
Accessories, spare parts and cables
4.2 Features
The TLK300, and TLK2000, telemetry device manage and control the alarms,
send/receive text messages (SMS), connect to external/internal GSM and PSTN
modems, WEB interfaces, send EMAIL and use the telecon control software
designed by RVR. The various function depend on product versions.
On the front panel there is also a set of LEDs, again depending on the preset
conguration,whichshowsystemstatusataglance.
In the case of the model TLK2000 is also present on the front panel is a clear user
interface which allows you to read and set the operating parameters; the entire
system can be controlled using the keys.
On rear panel are present all connectors to be used for connections to various
components of the station.
The TLK300, and TLK2000,telemetry system and relative management software
were designed to solve all of those problems arising from the management of
radio stations located in areas that are not easily reached or which would require
asignicantamountoftimefortheoperatortoreach.
4 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
The system has the following main functions (the functions depends on version
used) :
Management and control of alarms;
Telemetrization of operating parameters of device present in each station;
Sending and receiving of SMS;
Connecting to modem External / Internal GSM and PSTN;
WEB interfaces;
Sending of MAIL;
Use of TELECON management software developed by RVR;
Storage of events that caused faults.
This system allows remote management of the radio station, allowing the operator
to intervene immediately in the event of a fault.
On the rear panel are all of the connectors to be used for connecting the device
to the various station components.
The TELECON management software is easy to understand, as well as the WEB
interface used for remote management of the device it is fully compatible with all
browsers.
The TLK300, and TLK2000, telemetrysystemcomesindifferentcongurations
summarized below:
Version V1: serial telemetry unit for transmitter of Compact and Modular
family.
Version V2: GSM telemetry unit for transmitter of Compact and Modular
family.
Version V3: WEB telemetry unit for transmitter of Compact and Modular
family.
Version V4: GSM e WEB telemetry unit for transmitter of Compact and Modular
family.
5 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
4.3 Frontal Panel Description
4.3.1 Frontal Panel Description of TLK300
[1] MODEM Green LED, turns on when modem is connected and it is properly
initialized.
[2] ON Green LED, turns on when the equipment is connected to mains
power supply.
[3] WAIT YellowLED,whenashingindicatestheStartupofequipment.
When on, indicates that Start time is active. No alarm messages will
be sent until this LED turns off.
[4] SMS Yellow LED, indicates that it is transmitting an alarm signal by SMS.
[5] USB USBTypeBconnectorforprogrammingofrmwareandlocal
interfacing with TELECON software.
The USB connection automatically puts the unit in local mode.
[6] LAN Green LED, turns on when the LAN option is present and properly
communicating.
[7] LOCAL Yellow LED, turns on when the equipment is in local operating
status.
[8] ALARM Red LED, turns on when an alarm is present in the alarm list.
[9] STS Red LED, turns on when one of alarm condition is present.
[10] POWER ON/OFF switch.
6 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
4.3.2 Frontal Panel Description of TLK2000
[1] MODEM Green LED, turns on when modem is connected and it is properly
initialized.
[2] ON Green LED, turns on when the equipment is connected to mains
power supply.
[3] WAIT YellowLED,whenashingindicatestheStartupofequipment.
When on, indicates that Start time is active. No alarm messages will
be sent until this LED turns off.
[4] SMS Yellow LED, indicates that it is transmitting an alarm signal by SMS.
[5] Push button to move in the menu system and to modify the
parameters.
[6] ENTER Pushbuttontoconrmaparameterandtoenterinamenu.
[7] Push button to move in the menu system and to modify the
parameters.
[8] USB USBTypeBconnectorforprogrammingofrmwareandlocal
interfacing with TELECON software.
The USB connection automatically puts the unit in local mode.
[9] LAN Green LED, turns on when the LAN option is present and properly
communicating.
[10] LOCAL Yellow LED, turns on when the equipment is in local operating
status.
[11] ALARM Red LED, turns on when an alarm is present in the alarm list.
[12] STS Red LED, turns on when one of alarm condition is present.
[13] DISPLAY Liquid crystals display.
[14] ESC Push button to exit from a menu.
[15] POWER ON/OFF switch.
7 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
4.4 Rear Panel Description
4.4.1 Rear Panel Description of TLK300&2000 /V1
[1] PLUG VDE mains power supply connector.
[2] MAINS FUSE Fuse carrier.Use a screwdriver to access the fuse.
[3] 12 VDC IN + External 12Vdc supply input. Positive (red).
[4] I2C BUS DB9 female connector, for I2C sampling.
[5] I2C BUS DB9 male connector, for I2C sampling.
[6] 12 VDC IN - External 12Vdc supply input. Negative (black).
[7] RS232 / 485 DB9 female connector for serial sampling.
[8] RS232 DB9 connector for direct serial communication with the
TELECON program and software update in exchange with
frontal USB socket..
4.4.2 Rear Panel Description TLK300&2000 /V2
[1] PLUG VDE mains power supply connector.
[2] MAINS FUSE Fuse carrier.Use a screwdriver to access the fuse.
[3] 12 VDC IN + External 12Vdc supply input. Positive (red).
[4] I2C BUS DB9 female connector, for I2C sampling.
[5] I2C BUS DB9 male connector, for I2C sampling.
[6] ANTENNA SMA female connector for connection to a GSM antenna.
[7] 12 VDC IN - External 12Vdc supply input. Negative (black).
[8] RS232 / 485 DB9 female connector for serial sampling.
[9] RS232 DB9 connector for direct serial communication with the
TELECON program and software update in exchange with
frontal USB socket..
[10] SIM SIM card tray.
On the left side there is a status LED.
On the right side there is the eject button for SIM card tray.
8 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
4.4.3 Rear Panel Description TLK300&2000 /V3
[1] PLUG VDE mains power supply connector.
[2] MAINS FUSE Fuse carrier.Use a screwdriver to access the fuse.
[3] 12 VDC IN + External 12Vdc supply input. Positive (red).
[4] I2C BUS DB9 female connector, for I2C sampling.
[5] I2C BUS DB9 male connector, for I2C sampling.
[6] LAN RJ45 connector for TCP/IP communication.
[7] 12 VDC IN - External 12Vdc supply input. Negative (black).
[8] RS232 / 485 DB9 female connector for serial sampling.
[9] RS232 DB9 connector for direct serial communication with the
TELECON program and software update in exchange with
frontal USB socket..
4.4.4 Rear Panel Description TLK300&2000 /V4
[1] PLUG VDE mains power supply connector.
[2] MAINS FUSE Fuse carrier.Use a screwdriver to access the fuse.
[3] 12 VDC IN + External 12Vdc supply input. Positive (red).
[4] I2C BUS DB9 female connector, for I2C sampling.
[5] I2C BUS DB9 male connector, for I2C sampling.
[6] LAN RJ45 connector for TCP/IP communication.
[7] ANTENNA SMA female connector for connection to a GSM antenna.
[8] 12 VDC IN - External 12Vdc supply input. Negative (black).
[9] RS232 / 485 DB9 female connector for serial sampling.
[10] RS232 DB9 connector for direct serial communication with the
TELECON program and software update in exchange with
frontal USB socket..
[11] SIM SIM card tray.
On the left side there is a status LED.
On the right side there is the eject button for SIM card tray.
9 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
4.5 Connectors Description
4.5.1 RS232
Type: Female DB9
1 NC
2 TX_D
3 RX_D
4 NC
5 GND
6 NC
7 NC
8 NC
9 NC
4.5.2 I2C Bus
Type: Male DB9
1 NC
2 SDA
3 SCL
4 NC
5 GND
6 NC
7 NC
8 NC
9 NC
4.5.3 I2C Bus
Type: Female DB9
1 NC
2 SDA
3 SCL
4 NC
5 GND
6 NC
7 NC
8 NC
9 NC
10 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
4.5.4 RS485
Type: Female DB9
1 RS485 +
2 IC internally connected. Do not use.
3 GND
4 NC
5 IC internally connected. Do not use.
6 RS485 -
7 NC
8 NC
9 NC
4.5.5 USB
Type: Female type-B
1 +V In
2 D-
3 D+
4 GND
4.5.6 LAN
Type: female RJ45
1 TX+
2 TX-
3 RX+
4 NC
5 NC
6 RX-
7 NC
8 NC
11 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
5. Quick guide for installation and use
This section provides a step-by-step description of equipment installation and
conguration procedure. Follow these procedures closely upon rst power-on
andeachtimeanychangeismadetogeneralconguration,suchaswhenanew
transmission station is added or the equipment is replaced.
Oncethedesiredcongurationhasbeensetup,nomoresettingsarerequired
for normal operation; at each power-up (even after an accidental shutdown),
the equipment defaults to the parameters set during the initial conguration
procedure.
The topics covered in this section are discussed at greater length in the next
sections, with detailed descriptions of all hardware and rmware features and
capabilities. Please see the relevant sections for additional details.
IMPORTANT: When conguring and testing the transmitter in which the equipment
is integrated, be sure to have the Final Test Table supplied with the equipment ready
at hand throughout the whole procedure; the Final Test Table lists all operating
parameters as set and tested at the factory.
5.1 Preparation
5.1.1 Preliminary checks
Unpack the transmitter and immediately inspect it for transport damage. Ensure
that all connectors are in perfect condition.
The main fuse can be accessed from the outside on the rear panel. Extract the
fuse carrier with a screwdriver to check its integrity or for replacement, if necessary.
The fuse to be used is this type:
@ 230 ±15% Vac
TLK300 & TLK2000
@ 230 Vac/115 Vac (1x) 2A type 5x20
Table 5.1: Fuses
Provide for the following (applicable to operating tests and putting into service):
√ Single-phase mains power supply, with adequate earth connection.
√ Connection cable kit (NOT INCLUDED), including:
Cables for telemetry signals and sampling.
If a LAN output is present: Ethernet cable (with RJ45 connector) for connection
to ADSL router or LAN.
12 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
5.1.2 Connections
Note: the mains must be equipped with adequate earth connection properly
connected to the equipment. This is a pre-requisite for ensuring operator safety
and correct operation.
Connect the sampling cables of TLK300 or TLK2000 sources to output connectors
of system to telemetric data, such as the REMOTE connector of transmitters.
If LAN ouput is present, connect the ETHERNET output of TLK300 or TLK2000
to the appropriate input of your ADSL router or LAN network. If the connecting
device was different, identify an equivalent.
Connect the mains cable to the corresponding connector MAINS on TLK300 or
TLK2000.
 5.1.3 DipSwitchconguration
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Modem None
Modem PSTN
Option
x
Modem GSM
Option
x
Lan Option
x
Not used
x
Config TX
x
x
x
x
x
Not used
x
x
x
x
x
x
x
Table 5.2: Dip Switch
Belowthedifferentcongurations,thatCONFIGTXcanassume,arelisted.
Dip Switch, from position 1 to position 5, is to set as binary number based on the
congurationnumbertowhichreferenceismade(forexampletheconguration
12isequalto00110,ortheconguration20isequalto00101).
13 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
 5.1.3.1 CongurationoftransmitterVersionfromV1toV4
adr
TEX#1
TEX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 01
1
Config 02
1
4
Config 03
1
4
5
6
Config 04
1
4
5
6
7
Config 05
1
4
5
6
7
8
Config 06
1
4
5
6
7
8
9
Config 07
1
2
3
4
Config 08
1
2
3
4
5
6
Config 09
1
2
3
4
5
6
7
Config 10
1
2
3
4
5
6
7
8
Config 11
1
2
3
4
5
6
7
8
9
adr
PTX#1
PTX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 12
1
Config 13
1
4
Config 14
1
4
5
6
Config 15
1
4
5
6
7
Config 16
1
4
5
6
7
8
Config 17
1
4
5
6
7
8
9
Config 18
1
2
3
4
Config 19
1
2
3
4
5
6
Config 20
1
2
3
4
5
6
7
Config 21
1
2
3
4
5
6
7
8
Config 22
1
2
3
4
5
6
7
8
9
Table 5.3: TX congurations in versions from V1 to V4
14 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
5.2 Management Firmware
Note: ai ni di una maggiore chiarezza, sono riportati qui di seguito solo le
schermate tipiche del TLK2000. The TLK300 model is not equipped with LCD
display.
The equipment features an LCD with two lines by 16 characters that displays a
setofmenus.Thegurebelowprovidesanoverviewofequipmentmenus.
The symbols listed below appear in the left portion of the display as
appropriatei:i:
(Cursor) - Highlights selected (i.e. accessible) menu.
(Filled arrow) - Editable parameter marker. This symbol appears in menus that
take up more than two lines to aid browsing.
(Three empty arrows) - Parameter is being edited.
(Empty arrow) - Current line marker; the parameter in this line cannot be
edited. This symbol appears in menus that take up more than two lines to aid
browsing.
Switch on the equipment and verify that the led ON is lit. The LCD will display an
indication of the status of operation about modem and Lan.
Menu 1
15 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
Menu 1
General Menu
Alarms Menu
Modem Menu
Version Menu
LAN Menu
Menu 3
Menu 2
Menu 4
Menu 5
Menu 6
Menu 7
Menu 8
Selection Menu
Contrast Adjustment Menu
Predefined menu
Figure 1
When the display is off, touching any key will turn on backlightin..
When the display is on, by pressing the ENTER button for about 3 seconds while
you are in the default menu (menu 1), is used to call up the contrast adjustment
menu (menu 4). Once you choose the setting, by press ENTER again and you
willexitthepresentmenu,conrmingthechange.
Menu 2
When the display is on, by pressing the ESC button from the default menu (menu
1), calls up the selection screen (menu 3), which gives access to all other
menus:
Menu 3
If you want to return to the default menu (menu 1), simply press the ESC
button.
16 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
5.2.1 General menu (GenSts)
In this menu, you can toggle local control, set the address and speed of serial
ports, and set the time both of Start-up and of alarms generation.
To edit an item, highlight the appropriate line using the and buttons
and then press and hold the ENTER button until the command is accepted.
In this way, the setting is toggled between Local and Remote or viceversa. To edit
the parameters, simply select item and edit its value using the UP and DOWN
buttons;nally,pressENTERtoconrm.
Menu 4
Status The equipment can read and modify their own operating parameters
in local mode (LOCAL) through the navigation keys and rmware
management, excluding all other sources. The equipment can only read
in remote mode (REMOTE), but not modify the operating parameters,
except through commands provided by the LAN interfaces or GSM
connected.
RS232 Adress
Selection of serial address or USB for TELECON. The serial address
is relevant when the unit is connected to an RVR transmission system
which provides for use of this protocol. It is recommended, however,
to not change it for any reason. It is selectable from 1 to 200.
RS232 Baud Rate
Selection of the baud rate for the serial port data transfer selectable
between 1200, 2400, 4800, 9600, 19200 and 38400.
Start-up Time
Setting of start-up time expressed in mm:ss.
Alarm Time Out
Setting of time for alarms generation expressed in mm:ss.
17 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
5.2.2 Alarms menu (LogAlm)
This menu provides general information on the last twenty alarms stored in a non
volatile memory from the exciter.
In case the buffer is full, the previous alarms stored will have replaced with the
new one, normally it visualized the last alarm saved in memory.
To change the alarm displayed press the and buttons, turn until the indicator, turn until the indicator
ishighlightedonthe“Alarm”labelandthenpressagaintoconrm.Selectoneof
the twenty alarms choose itself from the list of alarms 1 ... 20 using the buttons.
Iftheuserconrmordoesn’tconrmthenewvalue(i.e.,theENTER button is not
pressed),thecursorstopsblinkingandremainsontherstalarmstored.
Menu 5
Alrm Visualization and selection of the stored alarm number.
Date Visualization of the alarm record date expressed as dd/MM/yy.
Time Visualization of the alarm record time expressed as HH:mm.
Description
Visualization of the of stored alarm name.
Note that these are readings, rather than settings, and cannot be edited (note the
empty triangle)..
18 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
5.2.3 Modem menu (MdmSts)
Note: this menu is present on TLK2000 only in version /V2, /V6, /V4 and /V8.
This menu provides general information on the modem in case it is installated in
the equipment:
Menu 6
Modem Cong
Visualization of modem type selected.
Modem Visualization of the modem status.
Signal Visualization of the GSM signal level received in antenna expressed in
dBm.
GSM Provider
Visualization of the customer number manager.
GSM Service
Visualization of the Service Centre Number.
Call Num.xx
Visualization of last 10 numbers for calls and SMS.
Note that these are readings, rather than settings, and cannot be edited (note the
empty triangle)..
19 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
5.2.4 Lan Menu (LanSts)
This page shows to the user the information about the presence of LAN interface
on the machine.
LanSts
IP Adress : 192.168.000.244
Network Mask: 255.255.255.000
Gateway : 192.168.000.001
Primary DNS : 192.168.000.250
Second. DNS : 192.168.000.250
Mac Adress : 00:00:00:00:00:00
Menu 5
IP Address
Showsthenumberthatunequivocallyidenties,withinasinglenetwork,
the devices connected to an IT network that uses the IP standard
(Internet Protocol).
Network Mask
Shows the subnet mask, necessary for the computer that must
communicate with another IP address to know if it should route packages
toward the gateway of its local network or use the address of the receiver
local network.
Gateway
Shows gateway address. In simpler networks, there is only one gateway
thatforwardstotheinternetnetworkalltheoutboundtrafc.Inmore
complicated networks where many subnets are available, each of them
referstoagatewaythatwillroutedatatrafctowardstheothersubnets
or forward it to other gateways.
Primary DNS
ShowstherstDNSserveraddress(DomainNameSystem);incase
the server should change the server hosting a service, or it is necessary
to change its IP address, it is enough to change the DNS record, without
changing client settings.
Second DNS
Shows the second DNS server address (Domain Name System); in
case the server should change the server hosting a service, or it is
necessary to change its IP address, it is enough to change the DNS
record, without changing client settings.
MAC Address
Shows the MAC (Media Access Control) address; this address is
uniquely assigned to the ethernet network card present on exciter. It
canbeusefulifyouwanttoaddinyourrouter,orrewall,alistofMAC
addresses of network cards authorized to connect to the network.
Note that these are readings, rather than settings, and cannot be edited (note the
empty triangle)..
20 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
5.2.5 Version menu (VrsSw)
This menu provides general information on the release installated:
Menu 6
Note that these are readings, rather than settings, and cannot be edited (note the
empty triangle)..
Rel Visualizationofrmwarerelease(rstrow)orBiosinformation(second
row).
Dat Visualizationofreleasedateaboutrmware(rstrow)orBios(second
row).
Cfg Visualization of table loaded set via dip-Swtiches.
21 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
6. IdenticationandAccesstotheModules
6.1 IdenticationoftheModules
The TLK300 and TLK2000 are made up of various modules linked to each
other through connectors so as to make maintenance and any required module
replacement easier.
6.1.1 TL300 and TLK2000 versions /V1 - Upper view
Thegurebelowshowstheequipmentupperviewwiththevariouscomponents
pointed out.
[1] USB & LED card
[2] Panel card (not present on TLK300)
[3] Mainboard & Power Supply card
[4] 16-bit CPU card
22 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
6.1.2 TL300 and TLK2000 versions /V2 - Upper view
Thegurebelowshowstheequipmentupperviewwiththevariouscomponents
pointed out.
[1] GSM Modem & Antenna
[2] USB & LED card
[3] Panel card (not present on TLK300)
[4] Mainboard & Power Supply card
[5] 16-bit CPU card
23 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
6.1.3 TL300 and TLK2000 versions /V3 - Upper view
Thegurebelowshowstheequipmentupperviewwiththevariouscomponents
pointed out.
[1] USB & LED card
[2] Panel card (not present on TLK300)
[3] LAN card
[4] Mainboard & Power Supply card
[5] 16-bit CPU card
24 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
6.1.4 TL300 and TLK2000 versions /V4 - Upper view
Thegurebelowshowstheequipmentupperviewwiththevariouscomponents
pointed out.
[1] GSM Modem & Antenna
[2] USB & LED card
[3] Panel card (not present on TLK300)
[4] LAN card
[5] Mainboard & Power Supply card
[6] 16-bit CPU card
25 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
7. Working Principles
7.1 Panel card
The panel card contains display and keys needed to interface with the user.
7.2 Mainboard
The main board carries out the following functions:
RS232, RS485, USB and I2C input/output treatment;
Signal Processing Control;
Management measures;
Distribution of power supplies
The power supply is a “direct from mains” type and it can be connected to any
voltage between 90 and 260 V without any adjustments or manual settings.
7.3 16-bit CPU Card
The CPU card is located on the mainboard.
This card is the heart of the equipment as it handles and processes all information
provided by the other cards and by other devices connected through the serial
interface.
ItispossibletoperformrmwareupdatesbydirectlyconnectingtheRS232output
of TLK300 & TLK2000 to serial or USB port of one PC.
The card has a diagnostic LEDs to verify it works.
7.4 USB card
This card adds an USB 2.0 port to allow connection to one PC by creating a virtual
serial port.
TheUSBconnectorisusedtoprogramthermwareandtointerfaceinlocalwith
TELECON software.
The USB connection automatically puts the equipmenti in local mode.
26 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
7.5 LAN card
This card adds a LAN port that allows you to connect itself to an equipment via TCP/
IP.Thevisualizationandmodicationofworkingparametersconcerntransmitter
is so possible using an Internet browser in added Java and Ajax features.
7.5 Alarm generation
Alarm generation parameters are listed below:
Alarm generation parameters are listed below:
Exciter output power (forward power good “PgD”);
Reectedpowerattheexciter(reectedpowergood“PgR”);
Temperature state (OVER TEMPERATURE);
Audio Signal presence;
Mains voltage state (present or missing).
An inhibit time (start time) after power-on is provided to ensure false alarm
prevention. When this inhibit time times out, the thresholds of alarm generation
parameters are checked and remote alarms are sent if needed.
Alarmgenerationtechniqueisoutlinedinthegurebelow;remotealarmdelay,
i.e. the amount of time the system waits before issuing a remote alarm after an
alarmconditionoccursisindicatedingure7.1.Whenappropriate,anewlineis
added to the alarm log stored, up to twenty lines maximum.
Figure 7.1
27 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
The alarm log may be reviewed using the “TELECON” software, or through SMS
(see relevant section) only for GSM model when connected to an external modem,
or through Trap viewable in a MIB browser only for WEB version with SNMP.
WARNING: The mains alarm is internally generated if the device is powered
through appropriate terminals with an external 12VDC; instead, an SMS message
indicating a normal condition is sent upon next start-up.
28 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
8. Web User Interface (WUI)
Once all connections previously described are performed, the equipment is ready
for commissioning.
The WUI (Web User Interface) allows you to adjust, modify or display the
conguration variables such as IP, netmask and gateway address. Follow the
procedure below to open the WUI:
1) Open your web browser on your PC, and connect to http://192.168.0.244
address to connect to the WUI(ifLANIPaddresswaspreviouslymodied,it
is necessary to use the new one). At this point the following page opens.
By factory the RVR uses the following adjustments:
IP address: 192.168.0.244
Netmask address: 255.255.255.0
Gateway address: 192.168.0.1
Menu 1
Nota : If address http://192.168.0.244 does not work, check and set IP address
as 192.168.0.XXX (where XXX is a gure between 1 and 254, excluding 244 that
is TLK300&2000 interface default address). To change the IP address, follow the
instructions in the manual or in the online guide and technical help, specic for
the Operating System you use.
2) Modify the parameters in accordance with the own needs.
3) Now interface is ready to remotely read data and modify the various settings
of the equipment.
29 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
8.1 Management Software
1) After access is made, the Main menu (main page) opens and shows possible
viewing options. This picture shows the Main menu after access:
Menu 1
To enter in one of the sub-menus, select the name and then click on item to
enter.
To go back to MAIN menu, just press the F5 key on your computer’s keyboard
to force the WEB page reload.
The page that appears is divided into three frames:
1) Title:ithasthelogoandanidenticationofthecurrentpagedisplayed.Itis
located on the top of the page.
2) Navigation menu: it allows you to select the page to display.
To enter into a submenu, select the name and then click on the item to enter.
3) Body: area where the page displays information about the selected menu.
30 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
8.1.1 Info Menu - User
Valuesfoundhereare“livereadings”,andassuchtheycannotbemodied.To
change the settings, use the operator or administrator General menu.
This page shows the user the data of TLK300 or TLK2000 interface:
Menu 2
Web Software Release
ShowsthereleaseofWEBrmware.
Web Software Date
ShowstheissuedateofWEBrmware.
Device Date
Shows the day stored on the equipment (dd/MM/yyyy).
Device Time
Shows the time stored on the equipment (hh:mm).
Local Date
Shows the day stored in your browser/PC (dd/MM/yyyy).
Local Time
Shows the time stored in your browser/PC (hh:mm).
Station Name
Shows the ID name of transmitting station.
31 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
8.1.2 Measure Menu - User
Valuesfoundhereare“livereadings”,andassuchtheycannotbemodied.To
change the settings, use the operator or administrator Command Menu.
The upper part allows you to enable or disable the Auto-refresh by clicking on
the relevant box.
With Auto-refresh enabled the measures are taken every 3 seconds (“Get
Data ..”) and gave available in a legible form by the current page (“Ready”).
With Auto-refresh disabled the measures are frozen (“Stopped”) at the time when
you uncheck the box and gave available in a legible form by the current page.
This page shows the user the data of the exciter connected to the TLK300 or
TLK2000 interface:
Menu 3
Nota: an example of TLK300 or TLK2000 connected to TEX-LCD, made by RVR,
is in the case shown above. The x next to EXC words is refer to the number of
exciter to which the measure makes reference.
Status
Shows the status of remote control.
Forward Power
Shows exciter forward power expressed in W.
Reected Power
ShowsexciterreectedpowerexpressedinW.
Temperature
Shows equipment internal temperature reading expressed in °C.
Exc x Freq.
Shows operating frequency of exciter expressed in MHz.
32 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
Exc x Mod.
Shows exciter modulation expressed in kHz.
Exc x Vpa
ShowsexciterampliermodulevoltageexpressedinV.
Exc x Ipa
ShowsexciterampliermodulecurrentexpressedinA.
Exc x Mod.L
Shows modulation on left channel of exciter expressed in kHz.
Exc x Mod.R
Shows modulation on right channel of exciter expressed in kHz.
Exc x PLL Lock
Shows the lock status at frequency set by PLL.
Exc x Audio Alarm
Shows the status of an impasse due to excessive SWR.
Exc x Foldback
Shows the triggered status of the foldback function (automatic reduction
of output power).
Exc x Ext R.F. Mute
Shows the status of power inhibition by an interlock signal.
CMD ON
Not allowed through User credentials.
CMD OFF
Not allowed through User credentials.
33 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
8.1.3 Alarm List menu - User
Valuesfoundhereare“livereadings”,andassuchtheycannotbemodied.To
change the settings, use the operator or administrator Alarm Delete Menu.
Within this menu you can display all alarms saved by the system: any new event
will automatically delete the older ones.
This page shows the user the alarms of the exciter connected to the TLK300 or
TLK2000 interface:
Menu 4
Type
Shows the alarm code.
Name
Shows the description for the error that led to event recording.
Time
Shows event recording time (hh:mm).
Date
Shows the day event was recorded (dd/MM/yyyy).
Value
Shows progressive number for event recording.
34 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
8.1.4 General Menu - Operator & Administrator
Note : Access to this menu and modi cation of these parameters are only possible
after login with operator or administrator rights.
This page not only shows the user the information about the exciter connected to
TLK300 or TLK2000 interface, but also allows setting various parameters.
Belowwillbedescribedonlyitemsthatallowthemodicationoftheparameter,
withrespecttotheInfomenu.Pressthebuttonstoconrmyourchoice;ifyoulet
timer to time out, the parameter setting will remain as previously set.
Menu 5
Web Software Release
ShowsIDnumberofrmwarerelease.
Web Software Date
Showsthedateofrmwarerelease.
Device Date
Allows you to align the date stored in the equipment with that of browser
device, by pressing the Syncronize Clock button (dd/MM/yyyy).
Device Time
Allows you to align the time stored in the equipment with that of browser
device, by pressing the Syncronize Clock button (hh:mm).
Local Date
Shows the current local Date stored relates on own browser/PC (dd/
MM/yyyy).
Local Time
Shows the current local Time stored relates on own browser/PC (hh:
mm).
Station Name
ShowsID(identier)nameoftransmittingstation.
35 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
New Station Name
Setting of the station name. Write the name in the box that you want to
assign, then press the Change Name button to apply the choice.
8.1.5 Command Menu - Operator & Administrator
Note : Access to this menu and modication of these parameters are only possible
after login with operator or administrator rights.
This page not only shows the user the information about the exciter connected to
the TLK300 or TLK2000 interface, but also allows setting various parameters.
The upper part allows you to enable or disable the Auto-refresh by clicking on the
relevant box.
With Auto-refresh enabled the measures are taken every 3 seconds (“Get Data
..”) and gave available in a legible form by the current page (“Ready”).
With Auto-refresh disabled the measures are frozen (“Stopped”) at the time when
you uncheck the box and gave available in a legible form by the current page.
Followingisadescriptionoftheitemsthatallowmodicationoftheparameter,
withrespecttotheInfomenu.Pressthebuttonstoconrmyourchoice;ifyoulet
timer to time out, the parameter setting will remain as previously set.
Menu 6
Nota: an example of TLK300 or TLK2000 connected to TEX-LCD, made by RVR,
is in the case shown above. The x next to EXC words is refer to the number of
exciter to which the measure makes reference.
Status
Shows the status of remote control.
36 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
Forward Power
Mostra la potenza diretta dell’eccitatore espressa in W.
Reected Power
Mostralapotenzariessadell’eccitatoreespressainW.
Temperature
Mostra la lettura della temperatura interna dell’ apparecchiatura
espressa in °C.
Exc x Freq.
Shows operating frequency of exciter expressed in MHz.
Exc x Mod.
Shows exciter modulation expressed in kHz.
Exc x Vpa
ShowsexciterampliermodulevoltageexpressedinV.
Exc x Ipa
ShowsexciterampliermodulecurrentexpressedinA.
Exc x Mod.L
Shows modulation on left channel of exciter expressed in kHz.
Exc x Mod.R
Shows modulation on right channel of exciter expressed in kHz.
Exc x PLL Lock
Shows the lock status at frequency set by PLL.
Exc x Audio Alarm
Shows the status of an impasse due to excessive SWR.
Exc x Foldback
Shows the triggered status of the foldback function (automatic reduction
of output power).
Exc x Ext R.F. Mute
Shows the status of power inhibition by an interlock signal.
CMD ON
Press Set to change the logical state of the data.
CMD OFF
Press Set to change the logical state of the data.
37 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
8.1.6 Alarm Delete Menu - Operator & Administrator
Note : Access to this menu and modication of these parameters are only possible
after login with operator or administrator rights.
Valuesfoundhereare“livereadings”,andassuchtheycannotbemodied.
Within this menu you can display the last 20 alarms saved by the system: any new
event will automatically delete the older ones. Using Reset item at bottom right of
the menu, you can delete all pending alarms.
This page shows the user the alarms of the exciter connected to the TLK300 or
TLK2000 interface:
Menu 7
Type
Shows the alarm code.
Name
Shows the description for the error that led to event recording.
Time
Shows event recording time (hh:mm).
Date
Shows the day event was recorded (dd/MM/yyyy).
Value
Shows progressive number for event recording.
38 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
8.1.7 Password Menu - Administrator
Note : Access to this menu and modication of these parameters are only possible
after login with administrator rights.
Thispageallowsthecongurationofloginasanadministratorandmaintenance
of TLK300 or TLK2000 interface via WUI:
Menu 8
User Password
Shows and set the password for user functions (parameter
read-only enabling).
The Erase button allows you to delete the password set for
maintenance.
Operator Password
Shows and set the password for operator functions (parameter
reading and partial change enabling).
The Erase button allows you to delete the password set for
maintenance.
Admin Password
Shows and set the password for administrator functions (parameter
reading and full change enabling).
The Erase All button allows you to delete the password set both for
the administrator and for the maintenance.
39 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
8.1.8 Network Menu - Administrator
Note : Access to this menu and modication of these parameters are only possible
after login with administrator rights.
This page not only shows the user the information about TLK300 or TLK2000
interface network connection, but also allows setting various parameters.
Press the Change Settingsbuttontoconrmselection;ifyoulettimertotime
out, the parameter setting will remain as previously set.
Nota : to make changes within these sub-menus you need to have through technical
knowledge of network management. It is recommended to have changes performed
by trained or quali ed personnel.
Note: The IP address must be set to static and does not have the opportunity to
acquire an address from DHCP server on network..
Menu 9
IP Address
Showsthenumberthatunequivocallyidenties,withinasinglenetwork,
the devices connected to an IT network that uses the IP standard
(Internet Protocol).
Subnet Mask
Shows the subnet mask, necessary for the computer that must
communicate with another IP address to know if it should route packages
toward the gateway of its local network or use the address of the receiver
local network.
Gateway
Shows gateway address. In simpler networks, there is only one gateway
thatforwardstotheinternetnetworkalltheoutboundtrafc.Inmore
complicated networks where many subnets are available, each of them
referstoagatewaythatwillroutedatatrafctowardstheothersubnets
or forward it to other gateways.
40 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
DNS1 server
ShowstherstDNSserveraddress(DomainNameSystem);incasethe
server should change the server hosting a service, or it is necessary to
change its IP address, it is enough to change the DNS record, without
changing client settings.
DNS2 server
Shows the second DNS server address (Domain Name System); in
case the server should change the server hosting a service, or it is
necessary to change its IP address, it is enough to change the DNS
record, without changing client settings.
MAC Address
Shows the MAC (Media Access Control) address; this address is
uniquely assigned to the ethernet network card present on exciter. It
canbeusefulifyouwanttoaddinyourrouter,orrewall,alistofMAC
addresses of network cards authorized to connect to the network.
New IP address
Set the new IP (Internet Protocol) number.
New Subnet Mask
Set the new subnet mask.
New Gateway
Set the new gateway address.
DNS1 server
SetthenewrstDNSserveraddress(DomainNameSystem).
DNS2 server
Set the new second DNS server address (Domain Name System).
41 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
8.1.9 Network Menu - Administrator
Note : Access to this menu and modication of these parameters are only possible
after login with administrator rights.
This page not only shows the user the information about sending messages through
TLK300 or TLK2000 interface network connection, but also allows setting various
parameters.
Press the Change Settingsbuttontoconrmselection;ifyoulettimertotime
out, the parameter setting will remain as previously set.
Note : to make changes within these sub-menus you need to have through technical
knowledge of network management. It is recommended to have changes performed
by trained or quali ed personnel.
Menu 14
Sender Address
Shows the transmission address used for sending messages.
Destination 1
Showstherstaddresstowhichalarmwarningmailmessagesshall
be sent.
Destination 2
Shows the second address to which alarm warning mail messages
shall be sent.
Destination 3
Shows the third address to which alarm warning mail messages shall
be sent.
Destination 4
Shows the fourth address to which alarm warning mail messages shall
be sent.
42 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
Subject
Showsthedescriptionofthe“subject”eldofmailincaseofsending
alarm messages.
Server Port
Shows the port used by TCP transmission protocol.
New Sender Address
Set the new transmission address used for sending messages.
New Destination 1
Setthenewrstemailaddresstowhichalarmwarningmailmessages
shall be sent.
New Destination 2
Set the new second email address to which alarm warning mail
messages shall be sent.
New Destination 3
Set the new third email address to which alarm warning mail messages
shall be sent.
New Destination 4
Set the new fourth email address to which alarm warning mail messages
shall be sent.
New Subject
Set the new description of the “subject” eld of the mail in case of
sending alarm messages.
New Server Port
Set the new port used by SMTP server for the transmission of email.
43 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
8.1.10 SNMP Menu - Administrator
Note : Access to this menu and modication of these parameters are only
possible after login with administrator rights.
This page not only shows the user the information related to the management
and supervision of the devices connected to the network via SNMP (Simple
Network Management Protocol), but also allows setting various parameters.
Press the Change Settingsbuttontoconrmselection;ifyoulettimertotime
out, the parameter setting will remain as previously set.
Nota : to make changes within these sub-menus you need to have through
technical knowledge of network management. It is recommended to have
changes performed by trained or quali ed personnel.
Menù 9
Actual Status
Viewing the status of the SNMP service.
Read Community
Viewing the set string for GET command that allows you to monitor
the different variables of the system managed.
Write Community
Viewing the set string for SET command that allows you to monitor
the different variables of the system managed.
Primary Trap IP
ViewingtherstTrapdestinationwiththeIPtowhichalarmwarning
messages shall be sent.
Primary Trap Port
ViewingtherstTrapdestinationwiththePorttowhichalarmwarning
messages shall be sent. The destination port of the Trap can not be
edited.
44 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
Secondary Trap IP
Viewing the second Trap destination with the IP to which alarm warning
messages shall be sent.
Secondary Trap Port
Viewing the second Trap destination with the Port to which alarm
warning messages shall be sent. The destination port of the Trap can
not be edited.
New Read Community
Imposta la stringa per il comando SET.
New Write Community
Imposta la stringa per il comando GET.
New Primary Trap IP
Set the identication number of the primary IP address set to send
the Trap signaling. It must be in dotted format XXX.XXX.XXX.XXX (ie:
192.168.0.5).
New Secondary Trap IP
SettheidenticationnumberofthesecondaryIPaddresssettosend
the Trap signaling. It must be in dotted format XXX.XXX.XXX.XXX (ie:
192.168.0.5).
Main MIB
By pressing the *.MIB you can download onto your PC, or browser
device,themainMIBlesofmanufacturerofproductstoredinTLK300
& TLK2000.
Specic MIB
By pressing the *.MIB you can download onto your PC, or browser device,
thespecicMIBlesofproductstoredinTLK300 & TLK2000.
45 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
9. Versions with GSM
This section describes the features introduced with versions
/V2 and /V4 (option with GSM telemetry) and the necessary steps for their proper
conguration.
These versions are able to handle remote the alarm reporting by sending SMS
messages through a internal GSM modem or through a dial-up external PSTN
modem (option on demand) by sending an alarm message string to a connected
PC.
Before querying the system using SMS messages, establish a connection using
the “TELECON” software and set the provider service centre number and the
telephone numbers authorised to send these commands to the devices.
When any one of the parameters listed above changes state, a text message with
thefollowinginformationissentviamodem(iftted):
Station Name.
Station ID.
State of measurements.
ES1. (example of TLK300/2000 in double exciter conguration with external
switching unit)
TLC ID:01-Station name-
FwdPwr1 OK-
RPwr1 OK-
Temp1 OK-
Audio1 OK-
Mains OK-
SCM Fault OK-
Audio2 OK-
ES2.(exampleofTLK300/2000insingleexciterconguration)
TLC ID:01-Station name-
FwdPwr1 OK-
RPwr1 OK-
Temp1 OK-
Audio OK-
Mains OK-
46 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
The versions with GSM support the following commands:
Command
Response
Description
INFO
Station Name: (string 16char max)
Station ID: (to 000 from 999)
FWD Power: (Exciter Forward Power in W)
RFL Power: (Exciter Reflected Power in W)
Temp: (Temperature in °C)
Tx ON (Tx state ON/OFF/STAND-BY)
Local (Local, Remote)
Alarm Present (Present/Absent)
Transmitter status
information
TXON
Station Name: (string 16char max)
Station ID: (from 000 to 999)
Tx is ON, Fault Command
Transmitter power-on
TXOFF
Station Name: (string 16char max)
Station ID: (from 000 to 999)
Tx is OFF, Fault Command
Transmitter power-off
ALARM
Station Name: (string 16char max)
Station ID: (to 000 from 999)
Alarm: (Last 4 alarm list store in memory)
Alarm log
RESET
Station Name: (string 16char max)
Station ID: (to 000 from 999)
RESET stored Record
Clear Alarm Log
STATUS
Station Name: (string 16char max)
Station ID: (to 000 from 999)
Status: Resend status alarm message
Resend the alarm status
information
VERSION
Station Name: (string 16char max)
Station ID: (to 000 from 999)
Release App, Release Bios, Table Code
Software Version
informations
Table 9.2 - V2 and V4 versions
Note: Response time to SMS commands may vary with different GSM network
providers; as a general rule, response time should not exceed 7-10 minutes
maximum.
47 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10. CongurationsofTransmitterSystem
Belowarelistedtheseveralpossiblesystemcongurations,thecongurationthat
needs to assume on the dip switch and the screens obtainable via WEB.
Note: for further information on the Dip Switch, please read the section on Dip
Switch Conguration present in this manual..
10.1 CongurationofTransmitterfromV1toV4Versions
10.1.1 CongurationofSystem01
Composition:
TLK (telemetry)
TEX-LCD (exciter)
TLK
(Telemetry)
TEX-LCD
(exciter)
Conguration #01: System
10.1.1.1 CongurationofDipSwitchforSystem01
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 1
x
Conguration #01: Dip Switch
48 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.1.2 I2C Address for System 01
adr
TEX#1
TEX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 01
1
Conguration #01: I2C Address
10.1.1.3 Command Menu - Operator & Administrator for System 01
Conguration #01: Screen Command
49 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.2 CongurationofSystem02
Composition:
TLK (telemetry)
TEX-LCD (exciter)
• PJ(amplier)
TLK
(Telemetry)
TEX-LCD
(exciter)
PJ
(Amplifier)
Conguration #02: System
10.1.2.1 CongurationofDipSwitchforSystem02
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 2
x
Conguration #02: Dip Switch
10.1.2.2 I2C Address for System 02
adr
TEX#1
TEX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 02
1
4
Conguration #02: I2C Address
50 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.2.3 Command Menu - Operator & Administrator for System 02
Conguration #02: Screen Command
51 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.3 CongurationofSystem03
Composition:
TLK (telemetry)
TEX-LCD (exciter)
HC-LCD (hybrid coupler)
• 2xPJ(amplier)
TLK
(Telemetry)
TEX-LCD
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
Conguration #03: System
10.1.3.1 CongurationofDipSwitchforSystem03
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 3
x
x
Conguration #03: Dip Switch
10.1.3.2 I2C Address for System 03
adr
TEX#1
TEX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 03
1
4
5
6
Conguration #03: I2C Address
52 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.3.3 Command Menu - Operator & Administrator for System 03
Conguration #03: Screen Command
53 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.4 CongurationofSystem04
Composition:
TLK (telemetry)
TEX-LCD (exciter)
HC-LCD (hybrid coupler)
• 3xPJ(amplier)
TLK
(Telemetry)
TEX-LCD
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
PJ (Amplifier) #3
Conguration #04: System
10.1.4.1 CongurationofDipSwitchforSystem04
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 4
x
Conguration #04: Dip Switch
10.1.4.2 I2C Address for System 04
adr
TEX#1
TEX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 04
1
4
5
6
7
Conguration #04: I2C Address
54 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.4.2 Command Menu - Operator & Administrator for System 04
Conguration #04: Screen Command
55 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.5 CongurationofSystem05
Composition:
TLK (telemetry)
TEX-LCD (exciter)
HC-LCD (hybrid coupler)
• 4xPJ(amplier)
TLK
(Telemetry)
TEX-LCD
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
PJ (Amplifier) #3
PJ (Amplifier) #4
Conguration #05: System
10.1.5.1 CongurationofDipSwitchforSystem05
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 5
x
x
Conguration #05: Dip Switch
10.1.5.2 I2C Address for System 05
adr
TEX#1
TEX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 05
1
4
5
6
7
8
Conguration #05: I2C Address
56 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.5.3 Command Menu - Operator & Administrator for System 05
Conguration #05: Screen Command
57 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.6 CongurationofSystem06
Composition:
TLK (telemetry)
TEX-LCD (exciter)
HC-LCD (hybrid coupler)
• 5xPJ(amplier)
TLK
(Telemetry)
TEX-LCD
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
PJ (Amplifier) #3
PJ (Amplifier) #4
PJ (Amplifier) #5
Conguration #06: System
10.1.6.1 CongurationofDipSwitchforSystem06
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 6
x
x
Conguration #06: Dip Switch
10.1.6.2 I2C Address for System 06
adr
TEX#1
TEX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 06
1
4
5
6
7
8
9
Conguration #06: I2C Address
58 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.6.3 Command Menu - Operator & Administrator for System 06
Conguration #06: Screen Command
59 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.7 CongurationofSystem07
Composition:
TLK (telemetry)
SCM-LCD (changeover)
2x TEX-LCD (exciter)
• PJ(amplier)
TLK
(Telemetry)
SCM-LCD
(Changeover
System)
TEX-LCD #1
(exciter)
TEX-LCD #2
(exciter)
PJ (Amplifier)
Conguration #07: System
10.1.7.1 CongurationofDipSwitchforSystem07
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 7
x
x
x
Conguration #07: Dip Switch
10.1.7.2 I2C Address for System 07
adr
TEX#1
TEX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 07
1
2
3
4
Conguration #07: I2C Address
60 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.7.3 Command Menu - Operator & Administrator for System 07
Conguration #07: Screen Command
61 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.8 CongurationofSystem08
Composition:
TLK (telemetry)
SCM-LCD (changeover)
2x TEX-LCD (exciter)
• 2xPJ(amplier)
TLK
(Telemetry)
SCM-LCD
(Changeover
System)
TEX-LCD #1
(exciter)
TEX-LCD #2
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
Conguration #08: System
10.1.8.1 CongurationofDipSwitchforSystem08
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 8
x
Conguration #08: Dip Switch
10.1.8.2 I2C Address for System 08
adr
TEX#1
TEX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 08
1
2
3
4
5
6
Conguration #08: I2C Address
62 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.8.2 Command Menu - Operator & Administrator for System 08
Conguration #08: Screen Command
63 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.9 CongurationofSystem09
Composition:
TLK (telemetry)
SCM-LCD (changeover)
2x TEX-LCD (exciter)
HC-LCD (hybrid coupler)
• 3xPJ(amplier)
TLK
(Telemetry)
SCM-LCD
(Changeover
System)
TEX-LCD #1
(exciter)
TEX-LCD #2
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
PJ (Amplifier) #3
Conguration #09: System
10.1.9.1 CongurationofDipSwitchforSystem09
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 9
x
x
Conguration #09: Dip Switch
10.1.9.2 I2C Address for System 09
adr
TEX#1
TEX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 09
1
2
3
4
5
6
7
Conguration #09: I2C Address
64 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.9.2 Command Menu - Operator & Administrator for System 09
Conguration #09: Screen Command
65 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.10 CongurationofSystem10
Composition:
TLK (telemetry)
SCM-LCD (changeover)
2x TEX-LCD (exciter)
HC-LCD (hybrid coupler)
• 4xPJ(amplier)
TLK
(Telemetry)
SCM-LCD
(Changeover
System)
TEX-LCD #1
(exciter)
TEX-LCD #2
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
PJ (Amplifier) #3
PJ (Amplifier) #4
Conguration #10: System
10.1.10.1 CongurationofDipSwitchforSystem10
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 10
x
x
Conguration #10: Dip Switch
10.1.10.2 I2C Address for System 10
adr
TEX#1
TEX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 10
1
2
3
4
5
6
7
8
Conguration #10: I2C Address
66 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.10.2 Command Menu - Operator & Administrator for System 10
Conguration #10: Screen Command
67 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.11 CongurationofSystem11
Composition:
TLK (telemetry)
TEX-LCD (exciter)
HC-LCD (hybrid coupler)
• 5xPJ(amplier)
TLK
(Telemetry)
SCM-LCD
(Changeover
System)
TEX-LCD #1
(exciter)
TEX-LCD #2
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
PJ (Amplifier) #3
PJ (Amplifier) #4
PJ (Amplifier) #5
Conguration #11: System
10.1.11.1 CongurationofDipSwitchforSystem11
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 11
x
x
x
Conguration #11: Dip Switch
10.1.11.2 I2C Address for System 11
adr
TEX#1
TEX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 11
1
2
3
4
5
6
7
8
9
Conguration #11: I2C Address
68 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.11.2 Command Menu - Operator & Administrator for System 11
Conguration #11: Screen Command
69 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.12 CongurationofSystem12
Composition:
TLK (telemetry)
PTX-LCD (exciter)
TLK
(Telemetry)
PTX-LCD
(exciter)
Conguration #12: System
10.1.12.1 CongurationofDipSwitchforSystem12
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 12
x
x
Conguration #12: Dip Switch
10.1.12.2 I2C Address for System 12
adr
PTX#1
PTX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 12
1
Conguration #12: I2C Address
70 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.12.3 Command Menu - Operator & Administrator for System 12
Conguration #12: Screen Command
71 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.13 CongurationofSystem13
Composition:
TLK (telemetry)
PTX-LCD (exciter)
• PJ(amplier)
TLK
(Telemetry)
PTX-LCD
(exciter)
PJ
(Amplifier)
Conguration #13: System
10.1.13.1 CongurationofDipSwitchforSystem13
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 13
x
x
x
Conguration #13: Dip Switch
10.1.13.2 I2C Address for System 13
adr
PTX#1
PTX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 13
1
4
Conguration #13: I2C Address
72 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.13.3 Command Menu - Operator & Administrator for System 13
Conguration #13: Screen Command
73 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.14 CongurationofSystem14
Composition:
TLK (telemetry)
PTX-LCD (exciter)
HC-LCD (hybrid coupler)
• 2xPJ(amplier)
TLK
(Telemetry)
PTX-LCD
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
Conguration #14: System
10.1.14.1 CongurationofDipSwitchforSystem14
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 14
x
x
x
Conguration #14: Dip Switch
10.1.14.2 I2C Address for System 14
adr
PTX#1
PTX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 14
1
4
5
6
Conguration #14: I2C Address
74 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.14.3 Command Menu - Operator & Administrator for System 14
Conguration #14: Screen Command
75 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.15 CongurationofSystem15
Composition:
TLK (telemetry)
PTX-LCD (exciter)
HC-LCD (hybrid coupler)
• 3xPJ(amplier)
TLK
(Telemetry)
PTX-LCD
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
PJ (Amplifier) #3
Conguration #15: System
10.1.15.1 CongurationofDipSwitchforSystem15
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 15
x
x
x
x
Conguration #15: Dip Switch
10.1.15.2 I2C Address for System 15
adr
PTX#1
PTX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 15
1
4
5
6
7
Conguration #15: I2C Address
76 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.15.3 Command Menu - Operator & Administrator for System 15
Conguration #15: Screen Command
77 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.16 CongurationofSystem16
Composition:
TLK (telemetry)
PTX-LCD (exciter)
HC-LCD (hybrid coupler)
• 4xPJ(amplier)
TLK
(Telemetry)
PTX-LCD
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
PJ (Amplifier) #3
PJ (Amplifier) #4
Conguration #16: System
10.1.16.1 CongurationofDipSwitchforSystem16
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 16
x
Conguration #16: Dip Switch
10.1.16.2 I2C Address for System 16
adr
PTX#1
PTX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 16
1
4
5
6
7
8
Conguration #16: I2C Address
78 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.16.3 Command Menu - Operator & Administrator for System 16
Conguration #16: Screen Command
79 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.17 CongurationofSystem17
Composition:
TLK (telemetry)
PTX-LCD (exciter)
HC-LCD (hybrid coupler)
• 5xPJ(amplier)
TLK
(Telemetry)
PTX-LCD
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
PJ (Amplifier) #3
PJ (Amplifier) #4
PJ (Amplifier) #5
Conguration #17: System
10.1.17.1 CongurationofDipSwitchforSystem17
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 17
x
x
Conguration #17: Dip Switch
10.1.17.2 I2C Address for System 17
adr
PTX#1
PTX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 17
1
4
5
6
7
8
9
Conguration #17: I2C Address
80 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.17.3 Command Menu - Operator & Administrator for System 17
Conguration #17: Screen Command
81 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.18 CongurationofSystem18
Composition:
TLK (telemetry)
SCM-LCD (changeover)
2x PTX-LCD (exciter)
• PJ(amplier)
TLK
(Telemetry)
SCM-LCD
(Changeover
System)
PTX-LCD #1
(exciter)
PTX-LCD #2
(exciter)
PJ (Amplifier)
Conguration #18: System
10.1.18.1 CongurationofDipSwitchforSystem18
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 18
x
x
Conguration #18: Dip Switch
10.1.18.2 I2C Address for System 18
adr
PTX#1
PTX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 18
1
2
3
4
Conguration #18: I2C Address
82 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.18.3 Command Menu - Operator & Administrator for System 18
Conguration #18: Screen Command
83 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.19 CongurationofSystem19
Composition:
TLK (telemetry)
SCM-LCD (changeover)
2x PTX-LCD (exciter)
• 2xPJ(amplier)
TLK
(Telemetry)
SCM-LCD
(Changeover
System)
PTX-LCD #1
(exciter)
PTX-LCD #2
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
Conguration #19: System
10.1.19.1 CongurationofDipSwitchforSystem19
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 19
x
x
x
Conguration #19: Dip Switch
10.1.19.2 I2C Address for System 19
adr
PTX#1
PTX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 19
1
2
3
4
5
6
Conguration #19: I2C Address
84 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.19.3 Command Menu - Operator & Administrator for System 19
Conguration #19: Screen Command
85 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.20 CongurationofSystem20
Composition:
TLK (telemetry)
SCM-LCD (changeover)
2x PTX-LCD (exciter)
HC-LCD (hybrid coupler)
• 3xPJ(amplier)
TLK
(Telemetry)
SCM-LCD
(Changeover
System)
PTX-LCD #1
(exciter)
PTX-LCD #2
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
PJ (Amplifier) #3
Conguration #20: System
10.1.20.1 CongurationofDipSwitchforSystem20
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 20
x
x
Conguration #20: Dip Switch
10.1.20.2 I2C Address for System 20
adr
PTX#1
PTX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 20
1
2
3
4
5
6
7
Conguration #20: I2C Address
86 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.20.3 Command Menu - Operator & Administrator for System 20
Conguration #20: Screen Command
87 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.21 CongurationofSystem21
Composition:
TLK (telemetry)
SCM-LCD (changeover)
2x PTX-LCD (exciter)
HC-LCD (hybrid coupler)
• 4xPJ(amplier)
TLK
(Telemetry)
SCM-LCD
(Changeover
System)
PTX-LCD #1
(exciter)
PTX-LCD #2
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
PJ (Amplifier) #3
PJ (Amplifier) #4
Conguration #21: System
10.1.21.1 CongurationofDipSwitchforSystem21
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 21
x
x
x
Conguration #21: Dip Switch
10.1.21.2 I2C Address for System 21
adr
PTX#1
PTX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 21
1
2
3
4
5
6
7
8
Conguration #21: I2C Address
88 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.21.3 Command Menu - Operator & Administrator for System 21
Conguration #21: Screen Command
89 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.22 CongurationofSystem22
Composition:
TLK (telemetry)
SCM-LCD (changeover)
2x PTX-LCD (exciter)
HC-LCD (hybrid coupler)
• 5xPJ(amplier)
TLK
(Telemetry)
SCM-LCD
(Changeover
System)
PTX-LCD #1
(exciter)
PTX-LCD #2
(exciter)
HC-LCD
(Hybrid Coupler)
PJ (Amplifier) #1
PJ (Amplifier) #2
PJ (Amplifier) #3
PJ (Amplifier) #4
PJ (Amplifier) #5
Conguration #22: System
10.1.22.1 CongurationofDipSwitchforSystem22
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Config TX 22
x
x
x
Conguration #22: Dip Switch
10.1.22.2 I2C Address for System 22
adr
PTX#1
PTX#2
SCM
HC o PA
PA
PA
PA
PA
PA
Config 22
1
2
3
4
5
6
7
8
9
Conguration #22: I2C Address
90 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
10.1.22.3 Command Menu - Operator & Administrator for System 22
Conguration #22: Screen Command
91 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
11. SNMP Telemetry
SNMP (Simple Network Management Protocol) is a worlwide protocol that allows
the management and supervision of the equipment connected to the network.
Measurements and commands are described by a MIB (Management Information
Base),whichisalistofOID(ObjectIdentier).EachOIDisavariablethatcan
be written (SET) or read (GET) through a NMS (Network Management System)
compatible with SNMP.
TheMIBisatextlewritteninASN.1anditisimportedfromtheNMSinorderto
know what OID can be expected by the AGENT (proxy card) and how to interpret
the information received.
Nota : The user can not freely distribute the MIB, unless written authorization
issued by the manufacturer. The MIB is property of the manufacturer.
The SNMP version used in this application is the v2, and is compatible with all
NMS systems.
Menu 1
Nota : Use a MIB BROWSER (not included) to use the MIB of RVR equipments.
These are usually provided in an accompanying CD with the system in which the
TLK300 & TLK2000 is installed.
11.1 MAIN MIB Description
The MAIN MIB reads and manages the main parameters of TLK300 & TLK2000
and provides general information related to manufacturer.
Through this MIB you can read, and in some cases set, parameters such as IP
address, Netmask, Gateway and DNS address.
It is also possible to manage IP address, time and date stored within the telemetry
system.
92 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
In cases where the parameter is a read-only, and you can not change it, it will be
indicated by a red X over the icon reference. In some cases to apply a particular
change, it is necessary to click on the OID item “Apply Changes”.
Note : In the following examples is used a MIB browser of ManageEngine, but
any MIB Browser can be used.
11.1.1 Reading and Settings of parameters
ThedescriptionofeachvariableisspeciedinsideMIB,whicharesubsequently
reported in the description box (Description) at the end.
Menu 2
The telemetry system is capable to sending Trap up to two different addresses.
Different addresses can be set using the OID in major MIB, in this case:
IP address for the destination of the Trap.
11.2 SPECIFIC MIB Description
The SPECIFIC MIB reads and manages the parameters administrated by TLK300
& TLK2000 included in transmitter station.
93 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
Through this MIB you can read powers (forward, reected or unbalanced),
temperature,voltagesandcurrentsonmodulesofpossibleampliers,exciters
and changeovers connected to TLK300 & TLK2000.
Note : In MIB browser will always display the maximum conguration of ampliers,
exciters and changeover available. The machines not present, will report zero
readings.
It is also possible to manage to control the switching on or off of transmitter, the
alarm reset, automatic or manual changeover.
In cases where the parameter is a read-only, and you can not change it, it will be
indicated by a red X over the icon reference. In some cases to apply a particular
change, it is necessary to click on the OID item “Apply Changes”.
Note : In the following examples is used a MIB browser of ManageEngine, but
any MIB Browser can be used.
11.2.1 Reading of Measurement
Each transmitter has a range of measures that can be read.
ThedescriptionofeachvariableisspeciedinsideMIB,whicharesubsequently
reported in the description box (Description) at the end.
Menu 3
94 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
11.2.1 Reading of Status
Similarly to measurements, each transmitter has a range of states that can be
read.
ThedescriptionofeachvariableisspeciedinsideMIB,whicharesubsequently
reported in the description box (Description) at the end..
Menu 4
The indications on the states can be of three types:
0 Indication of absence of the transmitter system component.
1 Indication of ON state, presence or activation of parameter.
2 Indication of OFF state, absence or deactivation of parameter.
11.2.2 Comand sending
Similarly to measurements, the commands have a number of OID that are only in
writemode.Foreachtransmitter,theMIBexportaspecicsetofOID.
The commands set are of two types: bistable (ON / OFF) or impulsive type.
Bistable control: in order to activate (ON), the user must send a “2” as value;
in order to disable (OFF), the user must send a “1” as value. No other value is
accepted like a command.
95 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
Impulsive control: tipically the commands are impulsive type. In other words, if
you put the transmitter “ON” (“2” value), the next command is “OFF” (“2” value)
and not a disable for “ON” command (“1” value).
Menu 5
Note: In the example above, all controls are impulsive type.
11.2.3 Reading and Settings of Trap
For each Trap related to measurement can be set:
Enabler Trap command on a power measure.
• Theminimumvalue(MIN)isthexedpointbelowwhichissentaTrap.
• Themaximumvalue(MAX)isthexedpointbeyondwhichissentaTrap.
The hysteresis value is a nominal value that the system adds (or subtracts) to
real value in order to exit from alarm condition. In other words, it is helpful to
avoid situations of continuous alarm, if readout is very close to the set point
alarm.
96 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
Hysteresis area
Menu 6
As you can see the hysteresis is a protected area in which the alarm is not sent,
when the value exceeds the minimum value (MIN) when there is no alarm or the
maximum value (MAX) alarm is active, the minimum value (MIN) alarm is set. To
exit the MIN alarm condition, the value should be equal to the MIN value plus the
value of hysteresis.
Note : the hysteresis value must be less than ½ referred to distance between the
minimum value (MIN) and maximum value (MAX).
An example of an analog alarm setting, are included in the following section in
the SNMP tree:
Menu 7
97 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
An example of an alarm where you can edit only the enabler of states is shown
below:
Menu 8
Below are shown the OID descriptions of the trap sent by system:
Menu 9
98 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
12. Connecting TLK to Internet network
In order to connect the system to the public network TLK you must have an
internet connection typically provided through a router with NAT (Network Address
Translation), which allows devices connected to the LAN to go out with the number
router’s public IP and protect any attempts at forcing.
In case you have connecting directly with the public IP address on the LAN socket
isadvisabletoinsertarouter/rewalltoavoidexposingthesystemTLKdirectly
to the public network but manage only the ports used by TLK for the functions of
the web interface, SNMP, and SMTP .
The system uses incoming port 80, can not be changed, such as web interface
visible from any Web Browser and port 161 can not be changed, such as SNMP
port.
For sending the email TLK uses port 25, modiable, and port 162 can not be
changed, for the sending of SNMP Trap.
To ensure that the TLK is visible from the outside is necessary that the router /
rewallissetupportforwarding,thefunctioncanhavedifferentnamesdepending
on the brand of your router.
The public port 80 from IP to the IP of TLK for WEB and port 161 of the public
interface to the IP of TLK for SNMP data.
To ensure that the unit can send the Trap and the Email needs to be able to use
the network at its output ports 162 for Trap and the port 25 for email.
To send the e-mail system TLK uses the MX record for the target domain DNS
askedthatmustbesetcorrectlyintheappropriateeldsotherwisenotbeableto
send emails.
Also for the emails you must make sure that the destination server accept email from
the public IP of our digestive system because the ships directly to the destination
SMTP server without going through a server forward as is usual practice for mailers
electronics installed on personal computers.
The apparatus as said default IP is set to RVR as 192.168.0.244 and will be adjusted
onthenetworkconguredasyourrouter’sLANportisusedforportforwarding.
If you have multiple devices connected to the LAN after the router is necessary to
usedifferentportsonthepublicinterfacethatwillberoutedtothexedportsof
the devices TLK must have a LAN IP different from each other.
99 / 100
User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
TLK#1 IP 192.168.0.244 Port forwarding port 80 > port 80 of 192.168.0.244
TLK#1 IP 192.168.0.244 Port forwarding port 161 > port 161 of
192.168.0.244
TLK#2 IP 192.168.0.245 Port forwarding port 81 > port 80 of 192.168.0.245
TLK#2 IP 192.168.0.245 Port forwarding port 163 > port 161 of
192.168.0.245
Withthisconguration,theapparatusTLK#1willbevisiblefromWEBashttp://
public.ip and apparatus TLK # 2 will be visible from as http://public.ip:81 WEB,
SNMP and how you must use port 161 to see the TLK # 1 and port 163 to see
the TLK # 2.
To send the Trap or Email being output there is no problem, as long as there are
no restrictions on using ports 25 and 162 are wanted by the service provider.
To know the public IP of our apparatus is desirable to have a FIXED IP connection
service that is provided by the provider, if the service has a dynamic IP you will have
to rely on a DNS service that gives a name to our IP and keep updated in the event
of a change of IP in order to reach the TLK always writing the same name.
This service is provided by many providers, some free and some paid, and usually
some routers include this function that can handle some of the service providers,
and in case you need to use this service will need to be programmed into your
router by following the instructions in that, given the various methods used to
manage this function, we can not include this function in the system TLK.
In case your nework TLK has many systems connected to the Internet the safest
way to manage and functional systems is to create a VPN between all stations and
the headquarters in order to have all the devices in the same network in order to
view them directly with their IP without the limitations of different ports for devices
in the same location, not all routers have this programming possibilities, limits the
output ports and having to manage any dynamic IP with a DNS service.
In this case, the customer will have to rely on a company that specializes in networks
tocongureyourVPNbetweenlocations.
100 / 100 User Manual
Rev. 1.0 - 13/06/14
ELETTRONICA
TLK300 & TLK2000 ( /V1, /V2 , /V3 & /V4 )
This page was intentionally left blank
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
R.V.R Elettronica S.p.A.
Via del Fonditore, 2 / 2c
Zona Industriale Roveri · 40138 Bologna · Italy
Phone: +39 051 6010506 · Fax: +39 051 6011104
e-mail: info@rvr.it ·web: http://www.rvr.it
The RVR Logo, and others referenced RVR products and services are trademarks of RVR Elettronica S.p.A. in Italy, other countries or both. RVR ® 1998 all rights reserved.
All other trademarks, trade names or logos used are property of their respective owners.
ISO 9001:2000 certified since 2000

Navigation menu