MJÃLNER600A Data Sheet Brochure
User Manual: MJÃLNER600A-Data-Sheet-Brochure
Open the PDF directly: View PDF .
Page Count: 6
Download | ![]() |
Open PDF In Browser | View PDF |
MJÖLNER 600 Micro-ohmmeter MJÖLNER 600 Micro-ohmmeter ▪▪Fully automatic testing – Micro processor controlled ▪▪Safe test – DualGround™ and Remote control ▪▪True DC – ripple free current ▪▪Lightweight suitcase – withstands the impact of water, dust or sand ▪▪Built ▪▪PC in thermal printer interface connection DESCRIPTION APPLICATIONS The MJÖLNER™600 is designed to measure the resistance of circuit breaker contacts, bus-bar joints, contact elements in bus-bars and other high-current links. The product has been designed with safety, ease of use and versatility in mind. MJÖLNER 600 test system is designed to serve a number of applications. The most common are contact resistance measurements of low-, medium- and high-voltage breakers and also at bus-bar joints, and other high current links. The micro-ohmmeter conducts true DC ripple free current and can be used anywhere to measure a low resistance value with high accuracy. With MJÖLNER 600 it is possible to make measurements according to the DualGround™ method. This means that the test object will be grounded on both sides throughout the test giving a safer, faster and easier workflow. The contact resistance measurements concerning breaker testing are particularly called for in the following standards: IEEE C37.09-1999 and IEC 62271-1 (2011). Choose the MJÖLNER 600 with excessive power resources for demanding applications, superior measurement accuracy and when 300 Amp continuous is required. If the contact resistance is too high this will lead to power loss and temperature rise, which often leads to serious trouble. To avoid such problems, it is necessary to check the resistance at regular intervals. The following table demonstrates how important low resistance is at high currents: The lightweight and rugged suitcase design makes MJÖLNER 600 an excellent choice when you need a portable solution in the field. When the case is closed, the product can withstand the impact of water, dust or sand – it even floats. Current Contact resistance Power loss 10 kA 1 mΩ 100 kW 10 kA 0.1 mΩ 10 kW 1 kA 1 mΩ 1 kW Optional accessories are a remote control and the PC software MJÖLNER Win with export functions for tables to Microsoft® Excel® 1 kA 0.1 mΩ 100 W At 10 kA a contact with the resistance 0.1 mΩ gives a power loss of 10 kW. This power loss in one single point will definitely confer a temperature rise, which may result in overheating and possibly premature failure. MJÖLNER 600 Micro-ohmmeter FEATURES AND BENEFITS 1. Grounding terminal 2. Connection for mains voltage 3. Switch for mains voltage 4. TEMP. SENSOR This interface is for connection of a temperature probe for temperature compensating. 5. INTERFACE For communication with PC and MJÖLNER Win. 6. DATALOGGER Port to connect a USB stick for datalogging. Results can be viewed with Excel. 7. REMOTE Remote control connector The remote controls current value, start /stop of measurement and print out function. 8. Printer Suitcase shape The unit comes close to the body thus making the unit easier to carry. Rugged plastic housing, in most cases no need for an additional heavy transport case. 9. Keys to control the menu functions 10. Start/Stop key with status LED 11. Adjustment keys to set the measuring current and all menu values 12. DC+ current output 13. Sensing terminals 14. DC- current output 15. Shunt output 16. Clamp sense input Current cables in separate bag Perfect balance when carrying the equipment. 1 12 2 3 13 14 4 5 6 15 16 7 8 9 10 11 MJÖLNER 600 Micro-ohmmeter APPLICATION EXAMPLES BOTH SIDES GROUNDED Circuit Breaker testing Many utilities require safety grounds remain in place during station outages, therefore, the MJÖLNER 600 was designed with this field safety constraint in mind. Test of circuit breaker contacts Test of the connections to the breaker Testing of Bus-bar Test of Bus-bar joints Test of connections Transformer testing Winding resistance – not on all type of transformers. (In many transformers there is a need for higher voltage than 5 V) Internal/external connections Everywhere you need to test a low resistance/ high current connection Switches Disconnecting Safety devices ground connections Welding points Minimum time shall be spent in the substation and focus shall be on the test rather than the equipment. The DualGround™ testing method is available for all tests on all circuit breakers. The following table indicates other test methods and Megger instruments that can use the DualGround testing: Timing TM1700/1800 with DCM module Motion TM1700/1800 Dynamic Resistance TM1700/1800 with SDRM202 Measurement (DRM) Equipment and methods that supports DualGround™ testing are associated with the DualGround symbol. This symbol certifies the use of groundbreaking technology and methods that enables a safe, fast and easy workflow with both sides grounded throughout the test. Fuses Cables Using the remote control you can measure the voltage drop (voltage) across each contact element within every section of the bus-bar being tested. You can make tests with both sides of the test object grounded, an additional safety feature. MJÖLNER 600 Micro-ohmmeter Outputs SPECIFICATIONS Specifications are valid at nominal input voltage. Specifications are subject to change without notice. Environment Application field Temperature Operating Storage & transport Humidity The instrument is intended for use in high-voltage substations and industrial environments. -20°C to +50°C (-4°F to +122°F) -40°C to +70°C (-40°F to +158°F) 5% – 95% RH, non-condensing SENSE 2014/35/EU 2014/65/EU General Mains voltage Input current (max) Protection Dimensions Weight Display Available languages Printer Thermal paper roll Current cables Sensing cables 100 - 120 / 200 - 240 AC, 50 / 60 Hz 39 A at 100 V, 18 A at 230 V (3 sec) Fuses (200 mAT and 400 mAT) Thermal fuse, Software Shut off temperature: 70ºC (158ºF) internal temperature 486 x 392 x 192 mm (19” x15” x 7.5”) 13.8 kg (30.4 lbs) LCD and LED English, Deutsch, Français, Espagñol, Svenska Thermal printer Width 57.5 mm, diameter 30 mm 2 x 3 m (9.8 ft), 35 mm² 2 x 3 m (9.8 ft), 2.5 mm² Measurement section Range Resolution Inaccuracy 100 A, ta 25ºC, R < 1 mΩ 50 – 600 A, ta 10 – 40ºC, R < 1 mΩ 0 – 999.9 mΩ 0.1 μΩ below 1.0 mΩ 1 μΩ below 10 mΩ 10 μΩ below 100 mΩ 100 μΩ below 1000 mΩ Typ. Max. ±0.2 μΩ ±1 μΩ ±0.3 μΩ ±2 μΩ ±0.7 μΩ 50 – 600 A, ta -20 – 50ºC, R < 1 mΩ ±1.1 μΩ 600 A, ta 10 – 40ºC, 1 mΩ < R < 8.4 mΩ ±6 μΩ 50 A, ta 10 – 40ºC, 10 mΩ < R < 100 mΩ ±80 μΩ 5 A, ta 10 – 40ºC, ±1 mΩ 100 mΩ < R < 1000 mΩ ±3 μΩ 50 – 600 A, ta 0 – 50ºC, R < 1 mΩ Current shunt Sense ranges Max. load capacity1) 300 A OUTPUT 100 μV/A Shunt output Inaccuracy 5 – 600 A DC (steps of 1 A) 5.25 V at 600 A 80 mVpp, 28.3 mVrms at 0 - 50°C (+32°F to +122°F) Continuous From internal shunt 60 mV at 600 A ±1% Inputs CE-marking LVD EMC DC+ / COM Range Max. output voltage Max. ripple ±4 μΩ ±50 μΩ ±500 μΩ ±10 mΩ 600 A, 60 mV 0-2 mV, 0-20 mV, 0-200 mV, 0-5 V INPUT DC current clamp Input sensitivity Input impedance 1) Max. 20 V between terminals and to protective earth(ground) Max. 20 V between terminals and to protective earth(ground) Adjustable 0.1 – 20 mV/A >1 MΩ At 25°C (77°F) ambient temperature MJÖLNER 600 Micro-ohmmeter OPTIONAL ACCESSORIES Extension cables Remote control Many times, you place the test equipment on the ground while the cables are connected high up on a circuit breaker. In these situations, it can save a lot of time using a remote control during the test. The remote control has most of the functionality in the MJÖLNER 600 such as starting and stopping, setting the test current and read out the test values. Temperature probe Extension cable sets, 5 m and 10 m. The 5 m set, GA-03205, includes two current cables 5 m, 35 mm2 and two sensing leads, black and red, 10 m. The 10 m set, GA-03205, includes two current cables 10 m, 35 mm2 and two sensing leads, black and red, 15 m. DualGround kit The temperature probe is used for temperature compensation of conductors (copper and other metals). MJÖLNER Win DualGround kit XA-12992, Current clamp, 200 A (XA-12792), test cables 5 m, black (04-35050) and red (04-35052). Note: Included in Ordering No. BD-19193 Calibration shunt The Windows program makes it easy to manage/save all test results in a simple way. All information, meta-data of the test object e.g. a circuit breaker and the test results are stored together and they can easily be transferred to Microsoft® Excel for further analysis. Calibration shunt, 200 A / 20 mV (BD-90022) MJÖLNER 600 Micro-ohmmeter INCLUDED ACCESSORIES Ground cable, 5 m (16 ft) 2.5 mm2 Cable set, current cables 2 x 5 m (16 ft), 35 mm2 ORDERING INFORMATION Item Art. No. MJÖLNER 600 Incl. Cable set, current cables 2 x 5 m (16 ft), 35 mm2 and sensing cables 2 x 5 m Ground cable, 5 m (16 ft) 2.5 mm2 BB-59091 Incl. Cable set, current cables 2 x 5 m (16 ft), 35 mm2 and sensing cables 2 x 5 m Ground cable, 5 m (16 ft) 2.5 mm2 DualGround kit, (XA-12992) BB-59093 Optional accessories Sensing cables 2 x 5 m (16 ft) MJÖLNER Win Windows® software BD-8010X Remote control With connection cable, 5 m (16 ft) BD-90010 Temperature probe BD-90012 Thermal paper roll (for printer) GC-00050 Extension cable set 5 m Current cables 2 x 5 m, 35 mm2 and sensing cables 2 x 8 m GA-03206 Extension cable set 10 m Current cables 2 x 10 m, 35 mm2 and sensing cables 2 x 13 m GA-03208 Calibration shunt 200 A / 20 mV shunt BD-90022 DualGround kit DC Current clamp 200 A and test cables 2 x 5 m (16 ft) XA-12992 Postal address MJÖLNER-600_DS_en_V08a Megger Sweden AB Box 724, SE-182 17 Danderyd SWEDEN Printed matter: Art.No. ZI-BB01E ◾ Doc. BB0383HE ◾ 2017 Subject to change without notice Registered to ISO 9001 and 14001 The word ‘Megger’ is a registered trademark T. 08 510 195 00 E. seinfo@megger.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Instance ID : uuid:bb26943b-a129-49ba-af4f-42922e20fd2b Original Document ID : adobe:docid:indd:2c5bbfc6-1d22-11de-a46b-8bb9e76daa46 Document ID : xmp.id:17A1D8B1DF92E71192A69D9712A2CBD4 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:16A1D8B1DF92E71192A69D9712A2CBD4 Derived From Document ID : xmp.did:F5993459DF92E71192A69D9712A2CBD4 Derived From Original Document ID: adobe:docid:indd:2c5bbfc6-1d22-11de-a46b-8bb9e76daa46 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2017:09:06 10:45:49+02:00 Create Date : 2017:09:06 10:45:49+02:00 Modify Date : 2017:09:06 10:45:57+02:00 Metadata Date : 2017:09:06 10:45:57+02:00 Creator Tool : Adobe InDesign CS6 (Windows) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 6 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools