The Autograph Monitor Screens Contain Most Common Information For Operator Mariner RS User Manual
User Manual: MarinerRS User Manual
Open the PDF directly: View PDF .
Page Count: 29
Download | |
Open PDF In Browser | View PDF |
MARINER RS SOFTWARE for ControlLogix HM1756 SGI-TSM Rev 1.00 1/10/2007 HELM INSTRUMENT COMPANY, INC. 361 WEST DUSSEL DRIVE MAUMEE, OHIO 43537 419-893-4356 419-893-1371 (FAX) TABLE OF CONTENTS Introduction ...................................................................................................................................2 Getting Started ..............................................................................................................................3 Setting Up RSLinx........................................................................................................................3 First Time Mariner RS Start Up....................................................................................................5 Position Input Zero Calibration.....................................................................................................7 HM1756 SGI-TSM Diagram & Description.....................................................................................9 Mariner RS Screens .................................................................................................................... 11 Monitor .......................................................................................................................................11 Current Alarm Settings...............................................................................................................13 Keyboard....................................................................................................................................15 Signature (Wave) Display ..........................................................................................................16 Wave Viewing Window...............................................................................................................17 Peak Tonnage History................................................................................................................21 Overlay.......................................................................................................................................24 Sequence Configuration.............................................................................................................24 Job Recipe Setup.......................................................................................................................28 1 MarinerRS Operating Instructions INTRODUCTION MarinerRS is the software tool that provides the easier way of configuring and monitoring the HM1756SGI-TSM module from existing operator interface via RSLink. SOFTWARE FEATURES Interface with up to 60 HM1756SGI Modules 2 or 4 Ch Tonnage & Status Screen Easy to Use Module Configuration Screen Sophisticated signature Analysis Screen Comprehensive signature overlaying to compare between different signatures You can store captured signature and recall later for analysis Point & Click read tonnage at angle for easy tonnage reading on signature screen. Peak History Graph (stores up to 10,000 peaks / ch) Peak history data export feature (Microsoft Excel format) Variety SPC Charts Individual & Range Average & Moving Range Median & Moving angel Average Standard Deviation Printing Chart Export (Bitmap, Meta File formats) Alarm History Job Storage Feature for Quick and Easy Job Download Multi-Level Password to protect unauthorized job changes ADC Feature to Automatically Download New Job parameters by PLC command. 2 MarinerRS Operating Instructions GETTING STARTED FOR FIRT TIME SETTING UP RSLINX 1. First, you need to set up the OPC Topics for each ControlLogix processor for all slides from RSLinx. Click on Topic Configuration at DDE/OPC from the menu bar. 3 MarinerRS Operating Instructions 2. Add OPC topics and connect to each ControlLogix processor * You need to create 6 Topics TONSLIDE1 for Rack No.1 TONSLIDE2 for Rack No.2 TONSLIDE3 for Rack No.3 TONSLIDE4 for Rack No.4 TONSLIDE5 for Rack No.5 TONSLIDE6 for Rack No.6 When you are finished, click Done to complete RSLinx setup. 3. Install MarinerRS software 4 MarinerRS Operating Instructions FIRST TIME MARINER RS START UP 1. Default setting of the software is configured for your current project. Therefore, the software should run without a problem. However, if you see Initializing message box or Connecting SEQ1 and these messages do not go away after you started the software, please wait until it times out. Usually, it times out within 30 seconds. Once it does, you can go to Setup screen and check SEQ Setup configuration table for trouble shoot. You can use the navigation buttons on top left side of the screen to go to different slide setup. 5 MarinerRS Operating Instructions 2. First, you have to enter the scale value for each slide. Go to Slide1 screen and click on ALARM SETUP button at the bottom of the screen. Click on EDIT button and enter a password to edit the setting on the screen. Default Password: Operator password = “123” Administrator Password = “123456” Master Password = “1968” There are some restrictions on editable contents based on the password type. Functions Operator Administrator Master Password Password Password Scale Value change X X O High Capacity Setting X X O Look Window Setting X X O Tracking Threshold Set X X O High/Low Tolerance setting O O O Alarm Switches & Settings O O O Learn Cycle Count O O O Tolerance Type O O O Alarm Window Setting O O O Low Alarm Inhibit Cycle Count O O O 6 MarinerRS Operating Instructions Use Master password to turn Edit on and click on the Scale Value display box, enter the scale value for the slide1. Normally, Scale value = Capacity of the slide / number of Channel 1. 2. 3. 4. 5. 6. 7. 8. Enter the value 10, for Tracking Threshold Set Enter Look Window Start angle at 90 Click on 0.6 button below to set Stop angle Normally set the High Capacity value same as the scale value. Click Download button for the changes on the modules to take effect Use the navigation buttons on the top of the screen to go to Slide 2 Repeat step2 –step7 Return back to main menu by clicking on the Return button Once all the basic settings are downloaded to the modules, you have to calibrate the position input for all the slides of the modules. POSITION INPUT ZERO CALIBRATION 1. Click SYSTEM SETUP button from main screen. 7 MarinerRS Operating Instructions 2. Click MODULE SETUP/CAL button to go to the MODULE SETUP & CALIBRAION screen 3. 4. 5. 6. Master Password is required for any changes on this screen. Click on CAL button to set the modules into Calibrate mode Enter current slide angle position at the PRESET ANGLE Click UPDATE button. You should see the current angles for AMCI RESOLVER, TONNAGE MODULE 1, and TONNAGE MODULE 2 become same as the PRESET ANGLE you entered previously. 7. Inch the slide and make sure all the current angle values follow the actual angle of the slide. If the AMCI REOLVER angle changes in reverse direction, change the RESOLVER DIRECTION option below. If the TONNAGE MODULE angle changes in reverse direction, you have to physically swap the S1 and S3 cables connection at the HELM SCA Convert module. 8. This completes the position input calibration. 9. Now the module is ready for actual load calibration. 8 MarinerRS Operating Instructions HM1756 SGI-TSM DIAGRAM & DESCRIPTION STRAIN GAGE INPUT STATUS OK ALARM STATUS / ALARM INDICATOR LIGHTS ANALOG RESOLVER INPUT RES. IN ANALOG RESOLVER OUTPUT RES. OUT STRAIN GAGE INPUT CONNECTOR CH1 GAIN AUTO-ZERO OFF POSITION CALIBRATE CH1 BALANCE +S CH1 SHIELD -S CH1 "LOOK WINDOW" & CH.1 OUTPUT TIMING WINDOW CH.1 & 2 ANALOG OUTPUT ANALOG OUT STOP OUTPUT STOP HIGH - LOW GAIN SWITCH +GAGE -GAGE +S CH2 SHIELD -S CH2 CH2 GAIN AUTO-ZERO OFF POSITION CALIBRATE CH2 BALANCE GN SW HELM INSTRUMENT CO., INC. MAUMEE, OHIO USA (419) 893-4356 Status / Alarm Indicator Lights Status light is on (green) when module is in Peak or Monitor Parts Mode. Status light is off when module is in Calibrate Mode. Alarm light is off when no tonnage fault is present. Alarm light is on (red) when tonnage fault is present. OK light is on (green) when PLC communication is OK. Module Setup All values are 0 (default) on initial start-up. This means that all alarms are disabled. You must make the following adjustments for proper operation: • • • • • • set calibration numbers set meter scale set capacity (maximum load) alarms set minimum load alarms set sample count set trend alarms 9 MarinerRS Operating Instructions Set the Run mode bit to Calibrate ⇒ From your operator interface, put the tonnage module into Calibrate mode. (The STATUS light on the tonnage module will turn off.) Balance Sensor Input 1. Set three-position switch to OFF (center) position 2. Turn balance potentiometer until 0’s are all displayed 3. If two sensors are wired, follow this procedure for both channels Calibration Numbers 1. Set three-position switch to calibrate (down position) 2. Turn Gain Potentiometer to dial in calibration numbers. 3. If two sensors are wired, follow this procedure for both channels. Always make sure that the three-position switch is in ON (top position) for normal operation. The remaining setup procedures can be accomplished with the Run Mode bit in either Bypass, Peak or Monitor Parts Mode. However, the Bypass Mode should only be used when setting calibration values or zero balancing the sensor input. 10 MarinerRS Operating Instructions MARINER RS SCREENS MONITOR SCREEN The monitor screen displays the tonnages, strokes per minute, parts count, alarm status, and alarm settings. Variations of the monitor screen include two, and four channel screens. The four- channel screen (Figure B1) contains five tonnage meter displays. Each corner meter displays the tonnage reading corresponding to the channel, and the center meter displays the sum of the four channels. The two-channel screen (Figure B2) contains two tonnage meters and a total tons meter. Figure B1 – 4 CHANNEL MONITOR SCREEN TREND LIGHTS All monitor screens contain a set of 9 “LED display trend lights” located to the left or right of each tonnage meter. These lights give the following alarm indications corresponding to that particular channel: Capacity Alarm: Top LED red Hi Tolerance (Track or Trend) Alarm: Top 4 LED’s Lo Tolerance (Track or Trend) Alarm: Bottom 4 LED’s The trend lights also give an indication of peak tonnage variation during the part making process. Tonnage values changing too high (or low) over (or under) the sample value, cause the LED lights to light up Figure B2– 2 CHANNEL MONITOR SCREEN above (or below) the center green LED. If the peak tonnage reaches the tolerance limits, a trend alarm will be triggered. Trend lights step (from center green, green, yellow, yellow, and red) in 25% increments of the difference between the sample and the tolerance limit. The tolerance limits are the boundaries set by the operator (high and low tolerance settings in the jobs screen) as the percentage (or tons) above and below the sample value to provide part quality control. 11 MarinerRS Operating Instructions MONITOR SETTINGS/READINGS Each monitor screen displays the strokes per minute (SPM), and parts count. Parts Batch is a value (set in jobs/settings screen) that stops the press when the parts count value reaches the parts batch value. The following settings are displayed adjacent to each tonnage meter: HCAP: Capacity alarm value in tons +TOL: High Tolerance (Trend/Track Alarm) setting in tons or percent SAM: Sample Value – “learned” during trending in tons -TOL: Low Tolerance (Trend/Track Alarm) setting in tons or percent REV: Reverse Load in tons At the top of the monitor screen, the corresponding sequence name and present job name are displayed. ALARMS HISTORY In case of tonnage alarm, this indicator will flash the message between “Alarm” and “Click here for Details” Click this indicator anytime to access details of the alarm message including previous alarms. BUTTONS At the bottom of the monitor screen are eight buttons activated when pressed. The left seven buttons may be “locked out” in the Supervisor screen to prevent operator use. Sequence Navigation button - Press the arrow buttons by the sequence name to navigate between different sequences. In general, each sequence represents one press or slide of up to four channels. Reset Button – Press button to reset any alarms, which caused the relay to trip and stop the press. Alarm Setup – Press to view or change Jobs settings Mode Buttons (CAL, SETUP, MONITOR) – Press button to change mode. System will be in one of the three modes: Calibrate, Setup, Monitor Parts (white button indicates present mode). More than one white button is an illegal mode, press a button to activate desired mode. Peak History – Press to view peak tonnage history records and SPC charting System Setup – This will lead to variety system related setup screen such as configuring modules, calibration of resolver input, press curve 12 MarinerRS Operating Instructions CURRENT ALARM SETTINGS SCREEN This screen (Figure B3) allows the operator to change alarm settings for current job. Keypad If you click on any green colored numeric display, a keypad will pop up so that you can make entry using touch screen. Job This displays the current job name that which was downloaded from the job recipe. Sequence Name The area in the top left corner displays the current sequence name being viewed. High Capacity Capacity alarms are active in setup and monitor-parts modes (not calibrate) usually for press protection. The typical values Figure B3 – CURRENT ALARM SETTINGS SCREEN entered are press capacity divided by number of channels. For example, on a 500 Ton press using four channels, capacities are set at 125 tons per channel. + / - TOL (Tolerance Alarm Values) Tolerance alarm settings correlate to both trend and tracking alarm settings. Select and enter valid range (050) if it is in percent, (0-255) if it is in Ton. These alarms are active in “monitor parts” mode only and are based off of the “learned” sample value. Entering a “0” into the keypad turns the tolerance (high or low) off for that particular alarm. Trend Alarms Trend alarms, are valid in “monitor-parts” mode only, and are base off of the “sample peak” taken during the “learn cycle”. Trend alarms provide a “parts quality” type of feature, triggering alarms if the peak tonnage goes out of range of the tolerance. Tracking Alarms Tracking alarms, are valid in “monitor-parts” mode only, and are based off of the “sample curve” taken during the “learn cycle”. Track alarms provide a thorough “parts quality” type of feature, because monitoring continues throughout the press stroke (based on the look window settings in the “Other Settings” screen). Delta Track The delta track feature pertains to the filtering of tracking alarms, and helps to avoid “nuisance” type of alarms. The filtering occurs during sudden force change within the press stroke. Delta track filtering can be seen in the wave screen, where high slopes of the sample signature (along with the tracking bands) get filtered during relatively small portions of the stroke. 13 MarinerRS Operating Instructions Press Curve Press Curve alarms are valid in “setup” mode only, and provide press protection. Data points are retrieved from the press manufacturer, and activated in the “press curve” screen. These points represent tonnage limitations per angle of the press stroke. During the part process, if the tonnage exceeds the press curve limitation at any specific angle, a press curve alarm is triggered. Press curve may be viewed in the “wave” screen. AMP Track The AMP track is another type of filtering to avoid “nuisance” alarms. The filtering consists of masking points where the variance between samples surpasses the alarm limit. Tons/Percent Tolerance alarms run in either tons or percent, which is selected in the jobs screen. At loads less than peak (throughout the stroke), tolerance in the percent mode is less than tons mode. This can be seen in the “wave” screen when comparing tons to percent. Learning Cycle The learning cycles (selectable 2, 4, 8, or 16) are the number of counts taken during the “sample” cycle of the system. Sampling occurs when the operator enters monitor- parts mode from setup-mode. After the number of press strokes reaches the set learning cycles, the module takes an average tonnage (and wave) per channel. This average is referred to as the sample, and becomes the benchmark in which the high and low tolerances are based Alarm Window The operator may choose to confine the alarm window to avoid possible nuisance alarms. Start and end angles must be within the look window. Select and enter values in keypad. Low Alarm Inhibit Cycle The low alarm inhibit cycle is the number of times that a less than low trend sample peak will be ignored before firing an alarm. Look Window The look window includes the start and end angles of the press, where alarm monitoring is active. The optimal settings are to start the look window at die contact with the stock, and end the look window at stock release. View waveform screen to verify desired look window settings (default settings are 60-283 degrees). To change start angle, select look window start angle and enter 30-285. Select end angle (1-6 choices depending on start angle value) below start angle reading, which is highlighted in green. Tracking Threshold Set The tracking threshold set feature sets a “bottom-line” when monitoring the tracking alarm. In Figure B3, the tracking threshold set is ten percent. This means that the tracking alarm will only monitored above the ten percent threshold limit. Scale Value Set the scale based on total press capacity divided by number of channels. For example, when using a fourchannel sensor system on a 500-ton maximum capacity press, set the scale to 125. 14 MarinerRS Operating Instructions Current Alarm Settings Buttons Edit – This button enables the user to allow editing of the current recipe that he/she is viewing. Download – Downloads the viewing recipe to the HM1756 SGI-TSM Save To Recipe - Saves the edited changes to the recipe for future use Job Recipe – Allows user to view another recipe Press Curve Setup – This button directs the user to a MarinerRS system that allows the operator to enter the specified 36 press curve points. Return - To “Monitor” screen. KEYPAD The Keypad allows the operator to edit number values, and is used in several of the MarinerRS Screens. This screen is accessed by clicking on a green colored numeric display to edit. Figure B4 displays the keyboard screen being used to edit values in the Current Alarms Setting Screen. Figure B4 – KEYPAD 15 MarinerRS Operating Instructions SIGNATURE (WAVE) DISPLAY SCREEN The wave (also called signature) screen (Figure B5) is reached by touching the tonnage meters in the monitor screen. The waves display the force (tons) versus the position of the press (usually in degrees) per channel. Variations of force per angle with each press stroke give an indication of problems in the part making process. Pressing the “Total” meter in the monitor screen allows the operator to view all four channels (two channels in two channel system) of waves. Pressing any of the “Channel” meters in the monitor screen, or pressing the wave in the four channel wave screen, displays the corresponding wave in a single wave format (Figure B5). This allows the operator to view a particular wave in a higher resolution. Figure B5 – SIGNATURE SCREEN The drawn waveform is based on the tonnage scale shown at the left axis, and the angle (or distance) shown at the bottom axis. The following key is given for the settings and values per channel. JOB This is the current job name downloaded from RECIPE MANAGER. PEAK Current peak tonnage value in tons for the channel currently displayed. HIGH CAP High Capacity Alarm setting value in tons for the channel currently displayed. LOW CAP (Not used) TARGET (Not Used) SAMPLE Sample value in ton, sampled from the learning process for the channel currently displayed. HIGH TOL High tolerance setting value in ton or percent for the channel currently displayed. LOW TOL Low tolerance setting value in ton or percent for the channel currently displayed. 16 MarinerRS Operating Instructions WAVE VIEWING WINDOW Figure B6 – WAVE VIEWING WINDOW ZOOM INDICATOR: HIGH CAP: HIGH TREND: LOW TREND: SAMPLE: SAMPLE WAVE: HIGH TRACKING: LOW TRACKING: CURRENT WAVE: Indicates the graph is currently zoomed High Capacity alarm band Upper limit of trend alarm band Lower limit of trend alarm band In SETUP and LEARN mode, it displays the Target bend In AUTOMATIC mode, it displays the Sample band Average of the current waves during the learning period Upper limit of Tracking alarm band around the Sample wave Lower limit of Tracking alarm band around the Sample wave Current tonnage signature read from sensor 17 MarinerRS Operating Instructions READ TONNAGE AT ANGLE Click on this button to read tonnage and angle at any desire coordinates from the signature screen. You can view up to 20 readings on a screen simultaneously. Use Back or Clear button at the top-right corner to delete unwanted readings. To delete last reading on the screen To clear all readings on the screen ZOOM IN The Zoom feature allows the operator to “zoom in” on a selected area of a wave for analysis at a higher resolution. Click this button to put the wave screen in zoom mode. Note: Once the wave is zoomed, a message “ZOOMED” shows up on the top-left corner of the Wave View Window to indicate that it is currently in zoomed portion of the signature. To select area to zoom in: Press touch screen (and keep pressed) at top left area of desired part of wave to zoom in, and drag finger at a diagonal down and to the right. A box will be drawn and finger followed as the touch screen is pressed. Release touch screen to draw zoomed-in part of the wave. Repeat Zooming is permitted to continuously zoom in on a particular area of a signature. 18 MarinerRS Operating Instructions RESET ZOOM Click this button to return to full view(unzoom) TREND TYPE Click this button to open the SELECT TREND GRAPH TO SHOW screen where you can Select the type of graphs you desire to overlay for Trend graph display feature. To select, click on the button you desire. When the button is pushed in, the option for the graph is on. Click again to deselect. TREND Toggle this button to show or hide the trend graphs selected from TREND TYPE option. This will give the visual references of the alarm settings and forming force related to the Sample Wave. GRID Click this button to show or hide vertical and horizontal grid lines on the wave screen. BOLD Click this toggle button to bold the current signature graph. 19 MarinerRS Operating Instructions LEGEND Click this button to show or hide the legend of the graphs displayed on the screen. CHANNEL SELECT Thru Select a button to display the corresponding channel signature on the screen. OVERLAY Click this button to view the overlay of 4 channel current signatures You cannot view Trend graphs in this screen. All other features are still available. 20 MarinerRS Operating Instructions PEAK TONNAGE HISTORY PEAK TONNAGE HISTORY displays last 500 recorded peak values as history graphs. It also provides the features to help analyzing the history data such as SELECTABLE CHANNEL, ZOOM, SCROLL, GRID, and more. Figure B7 – PEAK HISTORY VIEWING WINDOW CURRENT SEQ. allows you to select the peak history of the station you would like to view. Click the arrows to scroll through the different stations 21 MarinerRS Operating Instructions CHANNEL SELECT buttons help you to choose the channel history you desire to see. Push a button down to show the graph of the channel. Push again to hide the channel SCALE LOCK button gives you the choice of using a built-in auto-scale function to allow better analyzing of the peak history. This function can be toggled on and off. Click this button to toggle auto-scaling on/off button brings up the following export display from where you can export the EXPORT viewing peak history. Figure B8 – PEAK HISTORY EXPORT OPTIONS WINDOW 22 MarinerRS Operating Instructions CONFIG button opens a display to allow the user to edit the frequency of which peak history will be saved into memory. Click this button to open the display for storing peak history 100pt, 500pt, 1000pt buttons allows the user to configure the ‘resolution of their peak history graph. The 100pt, 500pt, and 1000pt buttons correlate to the amount of points that are used to construct the graph in the given time period. Click one of these three buttons to your preference of the graphing resolution. SCROLL buttons let you scroll left or right to view entire graph when it is zoomed. Click left arrow button to scroll left, right arrow button to ZOOMED MODE indicates that the current history graph has been zoomed. To zoom, point to the area on the screen where you want to start zooming and drag the point down to create a zoom rectangle. Once the inside of the zoom rectangle covers the area where you want to zoom, release the point from the screen. You can repeat this to continue zooming in the area. Click this button to reset the zoom and return to original size Click this button to show or hide vertical and horizontal grid lines on the wave screen. Click this toggle button to bold the current signature graph. Click this button to display or hide the legend 23 MarinerRS Operating Instructions OVERLAYS SCREEN The Overlays Screen (viewed by pressing the “Overlays” button in the wave screen) allows the operator to manage various stored waves, and select up to 20 wave overlays to be displayed in the wave screen. 1. Use <
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 29 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:c537b928-0c47-4a89-8c3b-8e7c4be68dbf Producer : Acrobat Distiller 6.0 (Windows) Company : helm Source Modified : D:20070112160139 Headline : Creator Tool : Acrobat PDFMaker 6.0 for Word Modify Date : 2007:01:12 11:03:23-05:00 Create Date : 2007:01:12 11:02:01-05:00 Metadata Date : 2007:01:12 11:03:23-05:00 Document ID : uuid:63fa1bd0-30ec-4740-9f93-d99ba4ce53ca Version ID : 103 Format : application/pdf Title : The Autograph Monitor Screens contain the most common information for the operator Creator : Dave Galvin Subject : Tagged PDF : Yes Author : Dave GalvinEXIF Metadata provided by EXIF.tools