Nuclear Data_Four_Input_Multichannel_Scaler_Module Data Four Input Multichannel Scaler Module
User Manual: NuclearData_Four_Input_Multichannel_Scaler_Module
Open the PDF directly: View PDF .
Page Count: 2
Download | ![]() |
Open PDF In Browser | View PDF |
TECHNICAL S P ECI F I CATI 0 N 5 NUCLEAR DATA INC Golf and Meacham Roads Schaumburg, Illinois 60172 Telephone (312) 885-4700 :: Four Input Multichannel Scaler Module General Description .n[ Nuclear Data’s Four Input Multichannel Scaler Module facilitates concurrent multichannel scaling from up to four inputs when used in conjunction with a Nuclear Data Multichannel Analyzer System. During multiple input multichannel scaling opera tion, each input is assigned to a separate memory group as selected by a front panel switch. The result is a separate record representing the data derived from each input with each record indicating the individual characteristics of its related source. FJ11:[4 Operti.on START 1 Multichannel scaling input pulses from up to four sources are applied to front panel BNC’s. Each accepted input is stored in the current channel of the respective memory group. Two front panel switches provide selection of 1, 2 or 4 multichannel scaling inputs and memory sizes of 512, 1024, 2048 or 4096 channels. The number of channels per input (scan) is the selected memory size divided by the number of inputs. Dwell time per channel is selected by an external ND536 Clock Time Base (Nuclear Data part number 88-0354) or similar timer. [nitiation of a multichannel scaling scan is accomplished by applying a start signal to a front panel BNC. Front panel BNC’s are also provided for dwell time input and an output which indicates when a multichannel scaling operation is in progress. AID 7L {. I I Technical Specifications Operating Modes: 1, 2 or 4 input multichannel scaling or OFF mode. In the OFF mode, normal pulse height analysis is enabled if an ADC is connected through the module into the Analyzer System. Count Inputs: Number 1,2 or 4. Input ImpedanceNominally 750 ohms. Pulse Amplitude +3 to +1OV. Pulse Width 200 nsec, minimum. Rate A function of the data acquisition storage cycle and number of inputs serviced. Count Capacity A function of the data acquisition channel capacity. - Scan Initiation: A multichannel scaling scan is initiated by applying an appropriate start signal to a front panel BNC. Start Input: Signal characteristics Dc level, +4 ±1V to start, +0.25 ± 0.25V quiescent. Duration 200 nsec, minimum. Maintaining the +4 ± 1V level or an open circuit causes free running repetitive multichannel scaling scans. - - - - - - Memory Storage Allocation: 512, 1024, 2048, or 4096 channels, switch selectable. Memory storage selection is dependent upon memory capacity of analyzer system. Power Requirements: +5 Vdc @ 500 mA. —12 Vdc @50 mA. Dimensions: 8.71 in. h. x 2.68 in. w. x 9.7 in. d. (NIM compatible two width module). Part Number: 88-0574. Dwell Time Selection: Dwell time per channel is selected by an external ND536 Clock Time Base or similar timer. C r4%: Specifications subject to change. Printed in U.S.A. 2/75 PS 1020 2.5 NUCLEAR DATA INC Sales and Service Facilities United States and canada Cleveland, Ohio Tel: 216/331-5145 New York, New York Tel: 212/962-3666 Washington, D.C. Tel: 301/345-6766 London, England Tel: 22733, 25357 Atlanta, Georgia Tel: 404/241-3220 Houston, Texas Tel: 713/443-1258 San Francisco, Calif. Tel: 415/483-9200 Europe Uppsala, Sweden Tel: (018) 15-25-15 Boston, Mass. Tel: 617/899-4927 Los Angeles, Calif. Tel: 714/540-5032 Schaumburg, Illinois Tel: 312/885-4700 Frankfurt, Germany Tel: 590540 Other Sales and Service Representatives located throughout the world. Please write or call Schaumburg, Illinois for your local representative.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 Modify Date : 2013:05:15 10:18:03+01:00 Metadata Date : 2013:05:15 10:18:03+01:00 Create Date : 2013:05:15 10:18:03+01:00 Creator Tool : Xerox WorkCentre 7530 Producer : Xerox WorkCentre 7530 Part : 1 Conformance : B Creator : Xerox WorkCentre 7530EXIF Metadata provided by EXIF.tools