PA SERIES
EQUIPMENT CONTROLS

INSTALLATION
OPERATION &
SERVICE MANUAL

EMERGENCY SHUT-OFF / POWER DISCONNECT
Model: PA600

For indoor and outdoor use, suitable for Pool/Spa equipment control
Electrical Rating: 1HP-120VAC, 3HP-240VAC, 20A-120/240VAC 840 Watt Tungsten
Double Pole Single Throw

IMPORTANT SAFETY INSTRUCTIONS
1. This Control must be installed by a qualified electrician, according to National and Local Electrical Codes.
2. USE COPPER CONDUCTORS ONLY. If applicable, install this Control not less than 5 feet (U.S.) 3 meters (Canada) from
inside edge of pool or spa, in line of sight from pool or spa.
3. Do not exceed the maximum ratings of individual components, wiring devices and current carrying capacity of conductors.
4. For grounding of the installation, refer to section 250 and 680 of the National Electrical Code.
5. Always disconnect electricity at main panel before servicing this Control.

READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL

GENERAL INFORMATION
This Switch is intended for disconnecting electrical
equipment from its power source quickly and safely,
in the case of emergency. Any person, even if not
familiar with the installation or safety procedures,
can shutdown the connected equipment by simply
moving the large red lever to the OFF position,
clearly indicated on the face of the switch.
The Switch is an enclosed construction, double
insulated switching device, suitable for indoor
or outdoor use and conforms to NEC article
680-12 & 680-38 requirements for disconnects and
emergency shut-off. It is ideal for new construction,
as well as for retrofitting existing installations, in
order to comply with the latest safety requirements
of the code. It can be used to disconnect any 120 or
240 volt resistive (R), tungsten (T) or motor (HP)
loads up to its rated capacity. It fits in a single gang
junction box and features pressure terminals for
convenient and secure field connections

1

INSTALLATION
This Switch is designed to be installed in a
standard flush or over the surface indoor/outdoor
single gang 11/2 inch or deeper junction box.
The method of installation, as well as the location,
must conform to the National and Local Electrical
and Building Codes. If not sure, please consult your
local inspection authorities prior to
installation.
1. Select the proper location for the switch. If it
is used for pool/spa pump disconnect, it must
be in line of sight from the pool or spa and at
least 5 feet (U.S.) 3 meters (Canada) away from
inside edge of pool or spa.
2. Prepare the necessary conduit runs as required
by the installation layout and pull in the required
conductors.
3. Make wire connections to the Switch, see diagram
on the right. Strip wires 3/8 inch and insert into
holes on sides of switch. Make sure the connections are tight.
4. Fasten switch to junction box tabs using (2) 3/4
inch long flathead screws supplied with Switch.
5. Place gasket over junction box and install cover
plate using (2) 3/8 inch long oval-head screws.
6.	Turn ON power at breaker panel and test
installation.

WARRANTY

If within one (1) year from the date of installation, this product fails due to a defect in material or workmanship, Intermatic
Incorporated will repair or replace it free of charge.
The warranty does not cover labor for removal or reinstallation and does not apply to: (a) damage caused by accident abuse,
mishandling, or dropping; (b) a unit which has been subject to unauthorized repair; (c) units not used in accordance with directions; (d) damages exceeding the cost of the product. Some states do not allow a limitation of damages so the foregoing warranty may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from
state to state.
This warranty service is available, if the defective product or its defective component is returned with proof of purchase
and date of installation, either (a) to the dealer from whom the unit was purchased or (b) by shipping prepaid to Intermatic
Incorporated/After Sales Service, 7777 Winn Rd., Spring Grove, IL 60081-9698/815-675-7000 http://www.intermatic.com
Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material
contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.

INTERMATIC INCORPORATED, SPRING GROVE, IL 60081-9698
http://www.intermatic.com

158T9795										

2

Printed in U.S.A.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.1-c037 46.282696, Mon Apr 02 2007 18:36:56
Instance ID                     : uuid:bbc3aa06-f899-4e36-9411-2a7011ac236d
Document ID                     : adobe:docid:indd:dc402f18-e5dd-11dc-9f80-f69eb6b860d7
Rendition Class                 : proof:pdf
Manifest Link Form              : ReferenceStream
Manifest Placed X Resolution    : 300.00
Manifest Placed Y Resolution    : 300.00
Manifest Placed Resolution Unit : Inches
Manifest Reference Instance ID  : uuid:7ACF903EE5E411DC9CCBAE1FED48B010
Manifest Reference Document ID  : uuid:7ACF903DE5E411DC9CCBAE1FED48B010
Create Date                     : 2009:02:03 13:55:24-06:00
Modify Date                     : 2009:02:03 13:55:26-06:00
Metadata Date                   : 2009:02:03 13:55:26-06:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 128
Thumbnail Height                : 128
Thumbnail Image                 : (Binary data 3675 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS3 (5.0.4)
EXIF Metadata provided by EXIF.tools

Navigation menu