SC19 6204 1_VM_SP_System_Messages_and_Codes_Rel_2_Apr82 1 VM SP System Messages And Codes Rel 2 Apr82
User Manual: SC19-6204-1_VM_SP_System_Messages_and_Codes_Rel_2_Apr82
Open the PDF directly: View PDF .
Page Count: 422
Download | |
Open PDF In Browser | View PDF |
SC19-6204-1 File No. 5370/4300-40 Program Product I BM Virtual Machine/ System Product: System Messages and Codes Program Number 5664-167 Release 2 I The term VM/SP, as used in this publication, refers to VM/SPI• Iwhen used in conjunction with VM/370 Release 6. I I~otice: This edition is a major revision of SC19-6204-0 and Technical Newsletters SN25-0822, dated December 29, 1980, SN24-5699, dated September 18, 1981, and SN24-5704, dated December 31, 1981. This edition applies to Release 2 of the IBM Virtual Machine/System Product (VM/SP) and to all subsequent releases until otherwise indicated in new editions or Technical Newsletters. For a detailed list of changes, see page iii. Technical changes and additions to text and illustrations are indicated by a vertical bar to the left of the change. Changes are periodically made to the information contained herein; before using this publication in connection with the operation of IBM systems, consult the IB~ 2~iglliL}70 ~nQ 430Q g£Q£~Q£§ BibliQg£~BhY, GC20-0QQ1, for the editions that are applicable and current. It is possible that this material may contain reference to, or information about, IBM products (machines and programs), programming or services that are not announced in your country. Such references or information must not be construed to mean that IBM intends to announce such IBM products, programming, or services in your country. Publications are not stocked at the address given below; requests for copies of IBM publications should be made to your IBM representative or to the IBM branch office serving your locality. A ~~~~ for reader's cemments is provided at the back of this publication; if the form has been removed, comments may be addressed to IBM Programming Publications, Dept. G60, P.o. Box 6, Endicott, New York, U.S.A. 13760. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation whatever. ~ Copyright International Business Machines corporation 1980, 1982 1981, Summary of Amendments Summary of Amendments for SC 19-6204-1 for VM/SP Release 2 PROGRAMMABLE OPERATOR FACILITY This facility provides the capability to: log messages, suppress messages, redirect messages, execute messages, or preprogram message responses. The capabilities are under control of an editable message routine table in a CMS file. Inter-User Communication Vehicle (IUCV) enhancements for message handling are also included. user-generated information from a virtual machine and CP information can be included. A utility program provides the user with the capability to print the collected information or display it on a terminal. NEW CMS END-USER FUNCTIONS New CMS end-user functions provide assistance for non-professional and professional users in utilizing the system. CMS NUCLEUS RESTRUCTURED This facility provides a CMS system that is more flexible and extendible for development, serviceability, and maintenance purposes. NEW CMS PRODUCTIVITY AIDS New CMS productivity aids provide the DP professional with several productivity enhancements. TRACE TABLE RECORDING FACILITY MISCELLANEOUS This facility records a history of system operations on spool. Selective recording of CP trace entries by type, VMBLOK address, interrupt code, and device type is provided. In addition, Minor technical and have been made publication. editorial changes throughout this Summary of Amendments for SC19-6204-0 as Updated by SN24-5704 for VM/SP Service Level 110 VM/SP SUPPORT FOR CONFIGURATION PROGRAM 3375 INPUT/OUTPUT The VM/SP version of the Input/Output Configuration Program allows an installation to specify the I/O configuration of the 3081 Processor Complex using CMS. VM/SP SUPPORT BUFFER (Feature The 32K FOR 3380 SPEED-MATCHING #655~ 3380 Speed-Matching Buffer uses storage buffer to modify the direct access data transfer path between the channel and the device. This feature allows attachment of the 3380 to either standard or high-speed System/370 channels. MISCELLANEOUS Various minor technical and editorial changes have been made throughout the publication. a Summary of Amendments iii Summary of Amendments for SC19-6204-0 as Updated by SN24-5699 for VM/SP Service Level 109 ACCESS VM/SP SUPPORT FOR G~APHIC AC~ESS METHOD/SYSTEM PRODUCT (GAM/SP), 56~8-978 VM/SP support for the 3375 is added. The 3375 is a count-key-data (CKD) version of the NFP DASD. VM/SP supports the ~375 as a spooling, paging, and system residence device. T-disk, mini-disk, and dedicated support is also provided. VM/SP support of GAM/SP Release provides access method services for the IBM 2250 Display Unit and the IBM 3250 Graphic Display System. These services provide for the creation of buffer programs for the termi~als ana for the transmission of the programs to (and handling of interrupts and data from) the terminals. VM/SP SUPPORT STORAGE DEVICE iv VM/SP Sys~em FOR 3375 DIRECT Messages and Codes Preface This publication is a reference manual designed for all users. It contains both messages and codes produced by the IBM Virtual Machine/System Product (VM/SP). Cross-Reference VM/SP Restrictions • Two components, CP and CMS, have been extensiveli modified and integrated into a VM/310 Release 6 base. This collective package (CP, CMS, RSCS, and IPCS) is referred to as VM/SP. The components RSCS and IPCS are technically at a Release 6 level of the product. They do not contain new function supportive of the new CP and eMS functions. However, there are recommended program products (Remote Spooling Communication Subsystem (RSCS) Networking, program number 5748-XP1) and Interactive Problem Control System (IPCS) Extension, program number S748-SA1) available that have been technically advanced to function supportively with YM/SP. This publication contains four sections: Introductiont System Codes, System Messages, and Appendixes. References to a standalone dump occur in One such various messages in this publication. program is the BPS storage Print program, Program No. 360P-UT-056. Messages with 4nxx identifiers (CMSBAM, CMSYSAM, and CMSAMS) are documented in other message manuals, as described under "Introduction". The following terms in this defined as follows: The format of messages VM/SP generates Syntax conventions this publication uses CP problem determination procedures The "System Codes" following catagories: • • • • • • are divided into "GAM/SP refers to the IBM GraphiC Method/System Product, 5668-978. • "270x" refers to IBM 2701, 2702, and 2703 Transmission Control units or the Integrated Communications Adapter (ICA) on the System/370, Model 135 • • "3270" refers to a series of display devices, the The use of display terminals is applicable to YM/SP supported system consoles used in display mode only. Information pertaining to the IBM 3284 or IBM 3286 printers includes any printers used for the display terminal copy function unless otherwise noted. of this • Control Program (CP) • Conversational Monitor System (CMS) Messages • Remote Spooling (RSCS) Messages Interactive Messages • "3330" refers to the IBM 3330 Disk Storage, Models 1, 2, or 11; the IBM 3333 Disk Storage and Control, Models 1 or 11; and the IBM 3350 Direct Access storage operating in 3330/3333 Model 1 or 3330/3333 Model 11 compatibility mode. • "3375" refers to the IBM 3375 storage Device. • "370x" refers to IBM 3704 Communications Controllers. • "3705" refers to the 3705 I and unless otherwise noted. • "FB-512" refers to the 3310 Direct Access Storage Devices. • "3081 h refers to the IBM 3081 processor. Information on the IBM 3081 processor is for planning purposes only until the availability of the product. Messages Communication Problem Control Subsystem System • Command-to-Message Cross-Reference • Message Summary Identifier • MeSsage-to-Module Cross-Reference • Message Alphamerically by Direct Access (IPCS) The appendixes cohtain: Text-to-Message Access that are supported as VM/SP terminal display stations. A specific device type is used only when a distinction is reguired between device types. Return codes CP wait state Codes Loader wait state codes RSCS wait state codes CP abend codes CMs abend codes The "System Messages" section publication is divided as follows: • publication are • . The "Introduction" contains: • • • User Documentation Page Message Identifier and IBM 3705 the 37ds II and the 3310 Preface v PREREQUISITE PUBLICATIONS IBM Virtual EXEC ~!£~Q !!.§~ Guid!, Order No. §ystem Product !Si!2I. £Q..!!!mand leference, Order No. SC24-5221 IntrodY£!iQll, Order No. GC19-6200 gnd Reference, Order No. SC24-5219 §ystem Pr.2.SY~ Edito,!: SC24-5220 Mac.hin~L§.Y§~~.!!! Pr2ill!£~: CMS Command SC19-6209- ~ Reference, Order No. Qi1~ .!.!!~ ~ lln2 i l l Control Block Logi£, Order No. LY20-0891 ,£.R £~ Refe~ fo!: No. SC19-6211 Operator's Remote (RSCS) Gui~~, ~lli ~:£.§, Order Also corequisite are programmer's guides to the various language processors. For anyone who uses the CMS ESERV command under CMS/DOS, the lli!i~~ 19 .t~ QOS/VSE Assemble!:, Order No. GC33-4024, is a corequisite because it contains all the ESERV error messages. Order No. SC19-6202 Spooli~ Communications Subsyst~.!!! User~ 2yid~, Order No. GC20-1816 Note: The VM/SP user should be aware that for more effective use of RSCS, the RSCS Networking Program Product (5748-XP1) is available and recommended. Interactive ,R£Qblgj! Cont,!:ol ~~.!!! User§ Guide, Order No. GC20-1823 (ll~§) Note: The VM/SP user should be aware that for effective use of IPCS, the IPCS Extension Program Product (5748-SA1) is available and recommended. more VSE/Advanced SC33-6098 VSE/VSAM SC24-5146 FUBgtiQll..§ Messaq!.§, Mesg~ Order No. order No. IBM Virtual Machine/Systgj! Product and §tand-Alone Versions: -InpU!LQutBut Configuration prQg~~'!!! User's §Yide An~ Reference, Order No. GC20-1843 COREQUISITE PUBLICATIONS Planni~ ~g §Ist~ 2~neration vi Error messages issued by the OS/VS and DOS/VS Analysis Program-1 (AP-1) are described in the Q§LV SAnd .QQ§L1§. Anal ySis Program-1 (.!f::l) ~!:!§ ~, Order No. GC26-3855. Messages received at the operator's console of the OS/VS virtual machine used in support of the Mass Storage System (MSS) are documented in the OS/VS ~Sl~ ~~I: Mass ~rage System (~§) ~ages, Order No. GC38-1000. The OS/VS EREP messages that are issued in the VM/370 CMS environment are documented in the Q§L!§, QOS/vg, VM/370 ERll Me§~g~§., Order No. GC38-1045. The GENIMAGE messages issued by the IEBIMAGE utility program can be found in the QSLVS Utilities ~~§, Order No. GC3S"'1005. Messages issued by the DOS/VS Sort/Merge Version 2 Program Product (5746-SM2) are described in the publication QQ§.LVS Sort/Merge Version 2 Programmer'§ ~~, Order No. SC33-4044.- Guide, Order No. SC19-6201 Syst2 Progra~!:.!.2 SC19-6203 The access method services (I DC-prefix) messages, the access method services return and reason codes, and the VSAM error codes are contained in the VSE/VSA~ Messag~ ~~g ~, Order No. SC24-5146. Order IBM VM/SP System Messages and Codes No. Messages issued by the IBM Graphics Access Method/System Product, 5668-978, are described int the publication £MS GAM/S.R User!§ Guide, LC33-0126. Contents INTRODUCTION • • • • • • • • • • o 1 VM/SP Message Format • • • • • • •1 VM/SP System Product Editor • • • •1 Messages With 4nxx Identifiers •1 Unnumbered Responses • • .1 Displaying Messages At The Terminal. .2 Special Message Facility .2 Syntax Conventions • • • .2 CP Problem Determination • .3 General User Action • • .3 System Operator Action • • • ... 3 SYSTEM CODES • • • • • • •5 Return Codes • • • • • • .5 Return Codes Produced by the CP DIRECT Command. • • • • • • • • ••••• 6 sample Return Code from a CP Command • • 6 Return Codes Produced by the CMS DDR Command • • • .. • • • • .6 Return Codes Produced by IPCS. .6 CP wait state Codes • • • .7 Loader Wait State Codes. 11 RSCS Wait State Codes. • • • • 13 CP Abend Codes • • • • • • • • • • • 14 System Operator Action • • • 14 System Programmer Action 14 CMS Abend Codes. • 38 User Action. • • • 38 CONTROL PROGRAM (CP) MESSAGES. • 43 CONVERSATIONAL MONITOR SYSTEM (CMS) MESSAGES. • • • • • • 111 CMS EDIT Messages. • • • • • 205 DEBUG Messages • • • • • • • .209 CMS EXEC MESSAGES. • 211 EXEC 2 MESSAGES. • o REMOTE SPOOLING COMMUNICATIONS SUBSYSTEM (RSCS) MESSAGES • • • .213 INTERACTIVE PROBLEM CONTROL SYSTEM (IPCS) MESSAGES • • • • • • • • • • .212 APPENDIX A. COMMAND-TO-MESSAGE CROSS-REFERENCE • • • CP Message Summary • • CMS Message Summary. • • • • • • RSCS Message Summary • IPCS Message Summary • • .237 .237 .252 .275 .279 APPENDIX B. MESSAGE SUMMARY ALPHAMERICALLY BY MESSAGE IDENTIFIER • • 281 CP Messages Summary • • .28 'I CMS Message Summary. • .298 RSCS Message Summary • • .321 IPCS Message Summary • .324 APPENDIX C. MESSAGE-TO-MODULE CROSS-REFERENCE • • • CP Message Summary • CMS Message Summary. • RSCS Message Summary • IPCS Message Summary • • • 0 327 .321 .333 • .340 .341 •• APPENDIX D. MESSAGE TEXT-TO-MESSAGE IDENTIFIER CROSS-REFERENCE • • • • • • • 343 CP Message Summary • • .343 CMS Message Summary. • • • • • • • • • • 362 RSCS Message Summary • .388 IPCS Message Summary • • • • • • 391 APPENDIX E. RESTRICTIONS • • • • • .393 VM/SP. • • • • • • • • • • .. .393 Restrictions - Channel Program • .393 Dynamically Modified Channel Programs. .393 Minidisk Restrictions. .. • • • • • • • .394 Timing Dependencies. • • • • • • • .. • .395 Processor Model-Dependent Functions. • .396 Channel Model-Dependent Functions. • • .397 Virtual Machine Characteristics • • 398 MSS Restrictions • • • • • • .400 CMS Restrictions • • • • • • .. .401 Miscellaneous Restrictions . .. • • • • • 403 • •• 0 APPENDIX F. USER DOCUMENTATION PAGE • • • 405 INDEX • • 0 .407 .231 Contents vii Figures Figure 1. Figure 2. Figure Fi9ur~ 3. 4. Figure 5. Figure 6. Figure Figure 8 .. Types and Meanings of Severitv Codes ................. 1 Syntax Abbreviations USed •••••••••••••••••••••••••• 2 viii 7. CP Error Message Numbers ....... 3 ~eturn Codes Ptoduced by the CP DIRECT Command ••••••••• 6 Example of a CP LINK Command ........................ 6 RetUrn Codes Produced by the eMS DDR Command ••••••••••• 6 CP ABEND Codes ••••••••••••••• 15 eMS ABEND Codes •••••••••••••• 39 IBM VM/SP System Messages and Codes Introduction This section describes: • • • --, I 1he fo~mat messages VM/SP genEIates. syntax conventions used in this publication. CP problem determination procedures. I Routine I Code 1 1----1--1 CP I A Commandsl I I W I E CMS Commandsl I tHIS! generates messages ftom the Centrol (CP), the Conversational Monitor System (C~S) , the Remote spooling Communications Sutlsystem (RSCS), and the Interactive Problem Control System P:PCS). j Pro9ta~ Messag~s consist of a message identifier and meSsage text. The identifier (for example, DMKCQG020E) uniquely identifies the message. The text is a shott phrase or sentence describing a condition that has occuIred or requesting a response from the user. The message identifier consists ef four fields: a component code, a module code, a message number, and a type code. The format of the message identi~ier is: • • • • Messages are I W E I S I I T RSCS I Commandsl I I I I R I IPCS I Commandsl I I Service I Routinesl I I I xxxm~mnnns is the component code. prefixed as follOWS: Immediate physical action Information Warning Q~ System Wait Error I I --------------------------·-------1 I R Response I VM/SP Message Format xxx I I I I Meaning E S T R I E S A D E I W I I I I I I I I I I I I I I I I I I I I , I I I Information Warning Error Severe error Terminal (unrecoverable) error Response Information Error Severe error Terminal (unrecoverable) error Response Information Error Severe Error Immediate physical action Immediate decision Eventual action Information System wait ----J L.....-.... Figure 1. Types and Meanings of Severity Codes Ctl messages -- DMK CMS messages -- OMS RSCS messages -- DMT IPCS messages -- DMM MESSAGES WITH 4nxx IDENTIFIERS mmm is the modUle code, three letters that indicate which module generated the message. This field is usually an abbreviation of the name of the module in which the error occurred. nnn is the message number, three digits are associated with the condition caused the message to b~ generated. s is the type code, a letter that indicates what kind of condition caused the message. The definition of the type codes defends on the nature of the routine producing the message, as shown in Figure 1. that that All messages issued from the CMSBAM discontiguous shared segment, as well as many of the messages issued from the CMSVSAM and CMSAMS discontiguous shared segments are identified by a 4nxx prefix. The text of these mess-a-g-e-sis.in VSE format rather than the standard CMS format. Explanations for these messages are not in this manual. The appropriate message manual to be used for reference for 4nxx frefix messages is determined by the associated access method. Messages relating to Sequential Access Method (SAM) are described in !.§UAdY..9!L£ed lY.!!S,:!:ioBE ]§2§s~~§. Messages relating to Virtual System Access Method (VSAM) are described in VS~L1E!~ ~M~§ snd Code§. UNNUMBERED RESPONSES VM/SP System Product Editor ~rror messages for the System Product Editor are section of this publication. III ne~ VM/SP System Product Editor messages are within the 500 range (DMSxxxSOO! - DMsxxx599S). located in the eMS All normal, unnumbered responses indicating the successful completion of a command (such as ready message, R;) are included in the !!L~~ £MS f£!l.!!lAllg A!!Q ]A£IQ Re~~.ll£~, the 111L.§g CP £Q.!!ll!!sllQ 1!~!~~!!£~ £.2£ ~.!!~,.§1 .Y~.£§, and the l~f QE~fs!2f~§ Quide. Introduction 1 r-------------------------------------------------, Short Form Meaning I Alphameric information Unnumbered responses can also be the result of executing system generation macro instruction or service programs. These responses, referred to as MNOTES, are documented in logic listings only. I I ----~---------------------------------I addr storage address 1 caw Channel address word cc Cylinder number I I I ---------------------------------------1 bbcchh Bin, cylinder, and head I ---------------------------------------1 callee Routine called by another 1 executing routine 1 --------------------------------------1 caller Routine doing the calling I Displaying Messages at the Terminal When you log on to VM/SP at your terminal, the default setting for the display of messages is TEXT. This means that only the text portion of the message appears when the message is displayed. The message identifier is not displayed. char Character csw Channel status word cuu Virtual device address cyl Cylinder 1 I 1 ---------------------------------------1 col Column 1 1 Since this book is organized by message numbers within component codes, it will be difficult for you to find the explanaticns of messages if you search through the book for the message text. Therefore, you should issue the CP command SET EMSG ON after you log on. This command causes the message identifier to be displayed along with the text. ---------------------------------------1 dasd Direct access storage I If you do not use the SET EMSG ON command, refer to "Appendix D: Message Text-to-Message Identifier Cross Reference" for the first line of the message. --------------------------------------1 device name Mnemonic name for cuu 1 ----------------------------------------1 device type IBM device type 1 No!~: fileid Syntax Conventions The syntax used in the messages and commands in this publication is as follows: Anything within quotes and/or in lowercase letters is replaced at execution time with information ~n the format described within the quotes. 2. Anything wi thin braces \ { ••• I ••• } indicates alternate text and/or information selected at execution time. 3. Anything within brackets [ ••• ] optionally left out, depending condition arising. may be on the See Figure 2 for a list of abbreviations used in this publication. i fn I I ft I fn ft [fm] 1 I filetype I I 1--------------------------------------1 I libname Library Name I I I mode I J I name I I nn I I nnnnnn I I psw Mode letter or mode letter and mode number Saved system name Decimal information Block numbers Program status word I I raddr I I rc I Real storage address Return code I rid I I rr Resource information Record number I I ssssssssss I I svc I I ucs I 1 vaddr I I xx Figure 2. IBM VM/SP System Messages and Codes device --------------------------------------1 filename I The Special Message Facility is a method of transferring special mes~a~es from a user to a specially programmed rece~v~ng virtual machine. The CP SET SMSG ON command is issued to allow a virtual machine to receive special messages. 2 1 ---------------------------------------1 fm filemode I SPECIAL MESSAGE FACILITY 1. 1 I 1 I Sense bytes Supervisor call number Universal character set I I I I I I 1 I 1 I I 1 I I I 1 I I 1 I 1 I I I 1 Virtual storage address I I Hexadecimal information I , Syntax Abbreviations Used 1 CP Problem Determination sure that the full error message function is in effect by issuing the CP command: CP error messages are divided into several categories according to the number (nnn) of the message. See Figure 3 for a complete list of message numbers and related functions. -------, 0- 1 I CP commands and ccnsole functionsl I Nucleus loading 1 I Paging I 1 Spooling I 1 Dispatching and service routines 1 Related Function 1 Numbers 1 1 001-349 1 1 350-399 SET EMSG ON 3. attain the virtual machine's current configuration by issuing the CP command: QUERY VIRTUAL 4. Where appropriate, and depending upon conditions, obtain a virtual storage dump by issuing the CP command: DUMP O-END 1----------------------------------I 400-424 1 I 425-449 I I 450-474 ------1 1 Directory routine 1 475-499 1 1 I 1 I Input/output error recording 1 1 Machine check reccvery 1 1 Reserved for IBM use only 1 ---I DDR (dump restore) service 1 program 1 1 FMT (format) service program I 1 JIR (directory) service program I Input/output error recovery I 500-549 1------------------------------I 550-599 1 I 600-649 SYSTEM 1 700-729 I 1 1 730-749 I I 750-799 1 Reserved for IBM use only 1 800-849 I 1 850-899 I I 900-999 I ACTION System operators (classes A, E, C, and D) who observe problems with CP commands should do the following: 1. Keep the console output the problem. 2. Attempt to reproduce the problem with full error message by issuing the CP command: 1------------------------------------I 650-699 I OPERA~OR sheet identifying SET EMSG ON 3. Obtain the real machine's configuration status by issuing the CP command: QUERY ALL 4. I I ----I service routine I I Checkpoint, warm start, dump 1 initialization I DMM (VMFDUMP) Reissue the CP command that has been causing the errors. If the problem recurs, force a CP abend dump by pressing the RESTART key (.B.Q! RESE'I). ~his technique automatically suppresses tracing while storage is being dumped. When the system restarts, use the VMFDUMP command to format and print the dump. .J Figure 3. CP Error Message Numters Caution: This will cause a system restart and all users must log on again. 'Ihe advantage of using this technique is that it provides you with a fO~~~!!~Q dump. The general user (class G) and other users receive error messages in the range 001 to 349. Messages ranging from 350 to 699 are for the primary system operator cnly. Messages ranging from 700 to 999 cover CP service routines and are usually observed only by system support personnel. If it is too disruptive to log off all users, you can obtain a dump using the CP command DMCP, which allows all users to on. Such a dump goes remain logged and is not directly to the printer formatted. Note: You must weigh the advantages disadvantages of both techniques. GENERAL USER ACTION 5. If in the normal use of CP commands error messages in the range of 001 to 349 perSist, the user should perform the following steps before contacting your system representative for programming assistance. 1. 2. Keep the terminal sheet that identifies the problem. Attempt to reproduce the problem, making and If you use the DMCP command, first reissue the CP command causing the problem. Then enter "alter/display" mode and display the following: (a) (b) (c) D P - PSW D G - General registers D C - Control registers Next, use the class A CP command MONITOR off tracing. S'IOP CPT RACE to turn Otherwise, the dump would show the dumping Introduction 3 activity in the trace table. CP command Then obtain the dump by issuing: ]g~: DMCP O-END Last, turn 4 tracing back on by issuing the IBM VM/SP System Messages and Codes MO~lTOR ST1R~ CP~RACE. If you do not have privilege class A, you can stop tracing by issuing the class C command STep to store X'OOOO- at locatiob X'400', and resume tracing by storing X'PFFF' at location X'~OO'. System Codes 8 Retufn Codes A return code of zero is passed to register 15 warning messages, error messages, severe ~rror messages, or terminal errer messages are generated during execution of a command_ if' no If however, during execution of a command, a condition arises that results in the display of a warning message, error message, severe error message, or terminal error message, the ccmmand passes a nonzero return cede in register 15. Commands that invoke program FIoducts pass a nonzero return code to the user. However, this return code has been redefined ty the program product or compiler in operation. 12 Errors were found in the input file. 20 There is an invalid character in the fileid. Valid characters are: 0-9, A-Z, $, m, I, and a-z. 24 The user did not command line. 28 An error occurred while trying to access, or manipulate, a user's files; for example, file not found. 32 The user's file is not in the expected format, or the user's file does not contain the expected informaticn er an attempt was made to execute a LCADMOD command while in eMS subset mode. This would cause the module to be loaded in the user area. 36 An error occurred in the user's devices. For example, a disk is in read-only status, and needs to be in write status in order to write out a file • 40 A functional error by the user occurred during execution of the command, or the user failed to supply all the necessary conditions for executing the command, or an end of file or end of tape was reached (where applicable). 41 Insufficient storage execute the command. A eMS system restriction prevented execution of the command, or the function requested is an unsuPForted feature, or the device requested is an unsupported device. !Q!§: The following list does not centai~ all return codes. other return cedes are shown in the descriptive text of the issuing message. Code ::0001 .... 0002 correctly specify the l!!s!!ia,g No CP command with this name was found. (The CP error code of +1 is cenverted by CMS to -0001 for commands entered from the virtual console.) . An attempt was made to execute a CMS while in CMS subset mode, which would have caused the module to be loaded in the user area (LOAtHCD error code 32). co~mand -000:3 Device errors occurred for which a Warning message is issued, or errors were introduced into the output file. No eMS command issued from EXEC was found with this name, or an invalid function occurred when issuing the SET or QUERY com~and from EXEC with IMPCP active. was available to -0004 The LOADMOD failed (fer example, was an error in the module). there 88 -0005 A LOAD MOD was attempted in the wrong environment (for example, the module was generated by the GENMCD command with the os option and LOADMOD was attemFted with DOS~ON specified) • 100 Input/output device errors. 104 A functional error for which the system is responsible occurred during execution of the command. 256 An unexpected error for which the system is responsible (Terminal Error) occurred during execution of the command. The user did not specify all the conditions to execute the command as intended. Execution of the command continUes, put the result mayor may not be as the user intended. System Codes 5 RETURN CODES PRODUCED BY THE CP DIRECT Return codes produced by the CP are listed in Figure 4. Code CCM~AND r DIRECT command -----------------,I Meaning 2 1 Invalid filename or file net fcund 1 ------I Error loading the directory I 3 Invalid option from 4 Directory not swapped, user not class A, B, or C 5 Directory not swapped, system directory locked 6 Directory not swapped, the directory in use by the system is not the directory updated C~S 1 1 I I I 1 I ipl cms VM/SP CMS - mm/dd/yy hh:mm cp link to * vaddr1 as vaddr2 r I Figure 5. Example of a CP LINK Command Return codes can be used by system programmers in the DEBUG subcommand and also in EXEC procedures. See the !~SP fMS f~~~~~£ and Macro Reference for a description of the &RETCOD~special variable. (old) RETURN CODES PRODUCED BY THE CMS DDR COMMAND 1xx Error in the CMS RDBUI routine 2xx Error in the CMS ~YPLIN The CMS DDR command produces several return codes. These return codes, along with their meanings are listed in Figure 6. routine xx is the CMS routine return code L Meaning Code J Figure 4. Return Codes Produced by the CP DIRECT Command SAMPLE RETURN CODE FROM A CP Invalid filename or file not fcund 2 Error running the program 3 Flagged DASD track 4 Permanent tape or DASD I/O error 1xx Error in PRINTIO routine 2xx Error in CONREAD routine 3xx Error in RDBUF routine 4xx Error in TYPLIN routine CC~MAND An example of the CP LINK command invoked while in CMS mode is shown in Figure 5. Commands or functions of commands passed to CP, in turn, pass the return code (via CP) to register 15. The user has entered the CP LINK command to userid *. The user's own directory will be searched for device vaddr1. Vaddr2 is the virtual address assigned to the device for this virtual machine. Read-only access is requested. No password is required because the user has linked to one of his own disks. xx is the CMS routine return code L-- Figure 6. Return Codes Produced by the CMS DDR Command The result will be one of the following: R·, a successful execution. RETURN CODES PRODUCED BY IPCS R(nnnnn); indicating an error. If nnnnn contains a CMS return code, the error occurred in CMS. However, if nnnnn contains a CP message identifier, the error occurred in CPo There are two return codes produced by These return codes are as follows: ~~gning An incorrectly entered parameter. 8 6 IBM VM/SP System Messages and Codes IPCS. System failure; a read/write invalid internal parameter. error or an CP Wait State Codes 001 Q]era!Q~ The machine check handler has encountered an unrecoverable failure. Probable hardware error. Issued by module DMKMCH and DMKMCT. Action: Reload (via IPL) the system. lithe problem peIsists, contact your system support personnel. ~~E!~natio~: Note: This wait state is also loaded malfunction alert occurred on the processor. 006 if a main This is a normal wait when a system shutdown is completed. Issued by module DMKCPI. ]~E1~~ation: Q~~~~!~ !£tign: procedures. Follow normal operating QE~~~!Q~ !ct!Q~: Run the System Environment Record Edit and Print (SEREP) program tefore restarting the system. !o restart, clear storage and IPL the VM/SP system, specifying CKPT start. If the Frotlem persists, contact your system support peIsonnel. Do not use the SEREP program on 3081 and 4300 processors as you will get invalid results. 007 ExB1anat~Qn: A program check, a machine check, a peImanent I/O error, invalid warm start data, an invalid warm start cylinder, or a full warm start cylinder was encountered by the checkpoint program. Issued by module DMKCKP. Q]§~~1~ 002 The channel check handler has encountered an unrecoverable failure. Protable hardware error. Issued ty module DMKCCH. ~~El~~atig~: gE~~~to~ !£!!Q~: Run the System Environment Record Edit and Print (SEREP) program tefore restarting the system. !c Iestart, clear storage and IPL the VM/SP system, specifying CKPT start. If the protlem persists, contact your system support personnel. Do not use the SEREP program on 3081 and 4300 processors as you will get invalid results. 003 cccurred A system failure before a valid warm start was peIformed. Issued by module DMKDMP. Actign: For message DMKCKP901W, run SEREP to document the machinE check, then contact your system support personnel. For message DMKCKP902W, an indication of an unrecoverable I/O error, move the SYSRES volume if possible and try to checkpoint the system. For message DMKCKP910W, if more than one SYSRES volume is mounted, check to see that the correct volume is loaded (via IFL) and try a checkpoint operation. If the operation fails again use the following procedure. This procedure is to be used for all other DMKCKP messages as well. 1. Dump the first 3000 hexadecimal storage locations. 2. Dump the warm start cylinders. 3. Contact program support persennel. 4. To restart, clear storage and initialize the VM/SP system, specifying CKPT start. ~~1~nat!Qn: Q~~tor Action: Reload (via IPL) the system. ~-the eIrOI persists, clear storage before attempting ancther IPl. If the problem persists after the secend IPL with cleared storage, a cold staIt is probably required. Save the dump produced on the prespecified dump device fer YOUI system support perscnnel. Refer to the message description for possitle causes. The following storage locations contain information related to wait state 007. Hexadecimal Location ----,-0- 004 ~~E1~~atio~: 40 A console or an output device is not operational, or a console or output device has produced an inexplicable error status. Probable hardware eIIor. Issued by module DMKDMP. 808 g~Iato~ 816 Action: Reload (via IPL) the system. To--restart, clear storage and IPL the VM/SP system, specifying CKP! start. If the problem persists, contact your system support personnel. 48 818 820 005 ~~lanation: The CP initialization module (DMKCPI) could not find an operational primary or alternate console. Probable hardware error. Issued by module DMKCPI. 828 848 800-17FF contents sense-aata up to 24 bytes Channel status word (8 bytes) Channel address word (4 bytes) Pointer to error message (4 bytes) Cylinder address of the first nucleus cylinder (2 bytes) Cylinder address of the last nucleus cylinder (2 bytes) Device class of SISBES device (RDEVTYPC) BBCCHHR of the DMKSAV module on disk--7 bytes (count-key-data) or locate block number (FB-512) Current seek address BBCCHHR Ccount-key-data) or locate block number (FB-512) Checkpoint program (DMKCKP) System Codes 7 1800-3000 Checkpoint work 4096-byte tuffer area and OOA If the SYSRES device is FB-512 (RDEVTYPC=CLASFBA), the contents of the following hexadecimal locations are changed: ~~]~s~!lgn: ~ mach~ne chec~ pcc~r~ed wb!le DMKSAV was attempt~ng to save or restQre a page image cOFY of the nucleus on a SlSR!S device~ Probable ~ardware error. lssue4 by module DMKSAV. Q~atoI Ac!i~~: 816 Block address of the first page of the CP nucleus (4 bytes) 822 Block addr~ss of the last page of the CP nucleus (4 bytes) An error message preceding the wait state mayor may not be displayed, depending upon the status of the console. If the error message is not displayed, hexadecimal location 808 contains the address of the error message (60 bytes in length). 008 Checkpoint and system shutdoWI) are complete or system recovery has failed. Issued by module DMKCKP. Run the System Env~ron~ept Record Edit and Print (SEREP) program before reloading. If the problem persists, contaPt your system support personnel. Do not ~SE the SEREP program on 3081 and 4300 processors as you will get invali4 results. OOB BUn the System Envir9nmeQt ReCord Edit and Print (SIREP) pro~ram tefqre performing another IPL. If the problem persists, contact your system sUPfprt persQnnel. D9 nQt use the SER~P program on 3081 and 4300 processor. as you will get invalid resul, ts" An IPL was pertormeq on a system volume that had never had a nUGle~s wri t ten OIl it. OOC A!.E.!anati.sm: Ac..ti.Q]!: If messagfSs pxeceded the wait, follow normal opexating procedures prescribed by your installation after shutdown. If messages did not precede the wait, either: Q~rat.QI The console printer was unavailable for some reason. Before initializing a new system, make sure the console printer has been made operational, or 2. The system is running from the alternate console. Messages DMKCKf910I, DMKCKP911W, DMKCKP960I, and DMKCKP961W do not appear on the alternate console. Follow normal operating procedures prescribed by your installation after shutdown. A machine check error occurred during system initialization~ PropatlE hardware error. Issued by module DKKCPI. Q]~r.tQS Act~oE: g.!.El~lBl.!:io!!: 1. jAE~s~s!i2B: Q.E~.a!.2! procedure. ODD Action: FQllow normal ~.E!2BS!~: The generated system is larger than the real machine size, or el~e a hardware malfunction has occurred wbich inhibits the system from us~ng the necessary storage. Issued by module QMKCPI. Q]~!g! !£$igB: Take a standalone notify the ~ystem programmer. OOE OpE;lx:at~n9 d~~~ and ~£lsBS!~2!!: An error cODdit~on prevents a CKP! start. Issued by module DMKCKS, Q]~s12! 009 lZ.E1E!!atio!!= An error which prevents a warm module DMKvlRM. condition occurred start. Issued by Q.E.§1lltof, l\cti:2!!: If the message is DMKWRM904W or DMKWRM921W, immediately retry warm start system initialization. If the error message recurs, move the VM/SP SYSRES pack to another location and try a warm start again. If message DMKWRM903W or DMKWRM912W is encountered, ensure that all system volumes (no duplicate labels) are correctly mounted, and then attempt a warm start. If warm start errors persist, force a system dump to the printer by preSSing the system console RESTART key, and save the results for the installation support Fersonnel. If the message is D~KWBM920W, restart the system uS1ng CKPT st.rt. Otherwise, use a FORCE or COLD start~ 8 ActigR: If message PMKCKS915E i~ issued, try CKPT start again. If t~e ~rror persists, move the VM/SF SYSRES ~ack to another PASD and trY ag~in. If mESSage DMKCKS916E is issued, reload (via IPL) the system, using the FORCE option of the S~ART cQmmand. If message DMKCKS903E or DMKCKS912E is issued, ensure that all system vQ!umes (no duplicate labels) are correctlY mounted, and then attempt a CKPT start. If message DMKCKS917E is issued, reload (via IPI) the system via a CCLD start. IEM VM/SP System Messages and Codes OaF being Hardware errors are received on the system paging device(~). Issued by module DMKPAG. ~£lgDg.!:i2n: Qperatgf ActigB: This wait state is preceded by message DMKPAG415E CON~INUQUS PAGING E~RORS FROM DAS.t xxx If there are multiple paging devices on thE system, disable the device pausing the errOr condition and re~oad (via IP~) the system. or, move the paging volume pack to another physical device. This error condition results if the system paging volume has not been formatted correctly. start. If the problem persists, your system support personnel. 015 010 ]z]lanation: A recoverable errcr occurred during a system nucleus save operation. Issued by module DMKSAV. Q~~g~Q~ !£~~Qn: This wait state is preceded by either the message DMKSAV350W or DMKSAV351W. Correct the protlem stated in the message and Fresent an external interrupt to initiate a retry. 011 ]X]l~atiQn: occurred. An unrecoveratle 1/0 Issued by module DMKSAV. This wait state is preceded by message DMKSAV352W or DMRSAV353W. Correct the problem stated in the message and load (IPL) the tape again. !£~~Qn: Follow normal operating procedure. 013 ~z]lgnation: The machine check handler encountered an unrecoveratle error cn the attached processcr. Probable hardware error. Issued by module DMR~CT. Notes: This wait state is also loaded if a malfunction alert occurred on the attached processor and CP was in contrel. This wait state is also issued by DMKAPI during Attached Processor initialization: either because of a malfunctien alert or unrecoverable machine check on the attached (being varied on) processor. Q~~tor Act~Qn: Run the System Environment Record Edit and Print (SEREP) program before restarting the system. If the problem persists, contact your system support personnel. Do not use the SEREP program on 3081 and 4300 processors as you will get invalid results. To restart, clear storage and system, specifying CKPT start. IPL A SIGP issued to the attached processor during system initialization by DMKCPI or DMKAPI was unsuccessful. The following information is made available: = SIGP order code = SIGP status information • RO • R1 SIGP condition code is 1 • R2 when the Processor address that was signalled Operator Action: If hardware errors are present, run--the System Environment Recerd Edit and Print (SEREP) program before retrying. If the status information indicates an cperator intervention, clear the condition on the attached processor and reinitialize CP. If the status indicator of the reguired microprogram is not loaded, load the micreprogram and reinitialize CP. If the problem persists, contact your system support personnel. Do not use the SEREP program on 3081 and 4300 processors as you will get invalid results. Explg~gtioB: This is a normal wait state on completion of a nucleus load. Issued by module DMKSAV. Q]~~gto~ Ex]1anat~QB: Note: The wait state PSi will contain the condition code returned from the SIGP. ~he FSW is in the BC format. Refer to the IBM g£in£~]les Q! Q]erat~QB for--a 2Y§~~}!nlQ description of the SIGP functional instruction. error Q~~~Q£ Act~Qn: 012 contact 016 Elilsnat~Qn: (1) The CP initialization module (DMKCPI) could not connect the channel set to the main processor or the IPL device is not accessible through any available channel set. Probable hardware error. Issued by DMKCPI. (2) A hardware error occurred on the 1/0 processor or the 1/0 processor was being varied offline. An attempt to disconnect, then connect the channel set to the attached processor failed. Probable hardware error. Issued by DMKCPU. Q]~£s~ion !£!~Qn: Run the System Environment Record Edit and Print (SEREP) program before restarting the system. If the problem persists, contact your system support personnel. the VM/SP cannot checkpoint and warm start after a machine check error on System/370 Models 165 and 168. The inability to warm start is caused by running the 165 or 168 SEREP program. To restart, clear storage and initialize the VM/SP system, specifying checkpoint start. Mot~: 014 ~~l~ation: A failing storage frame was encountered during a CP system save or check peint operation. Issued by DMKSAV and DMKCKP. g~~1~ Action: Run the System Envirenment Record Edit and Print (SEREP) program before restarting the system. To restart the system, clear storage and initialize (via IPL) the VM/SP system, specifying CKP~ 017 l!Blgnation: An input/output error occurred trying to read page 2 of the DMKCKP module from the system residence volume (either at IPL or restart). the input/output !£ti~: Correct error condition and IPL the system again. Issued by module DMKCKP. gE~~Q£ 018 lZ]1gnation: Invalid TOD clock. The clock must be set before an IPL can be completed. Issued by module DMKCPI. QB~£s!~ Act~QB: that fails, Manually do a clock set; if call IEM for hardware System Codes 9 assistance. 019 01B J~E!~2!: (1) This processor is being terminated, and its new PSis have teen set up by the processor termination routine to load disabled wait PSWs with code X'019'. This processor then took an interruption. (2) The processor termination routine was entered on this processor while processor termination was in process for this processor. (issued by DMKMCT). (3) Processor termination was in process for the other processor, but the other processor continued to run and obtained a system lock. (Issued by DMKCPP and DMKMC'I.) Q~~at2I Action: Use IPt FMT program to check the allocation extent map (use !ID statement only to display current status). In case of error, correct it and IPt the system again. Note: The problem can occur even when the allocation extent map looks correct, if the system residence volume was restored or copied from a different sized FB-512 device (for example, from 3370 to 3310). Bunning IPt FMT's allocation function with END as the sole entry will fix this. QR§!A!£! Action: Usually caused tj bad status received during a SIGP, which initiates processor terminaticn actions. The bad status may have been caused by hitting the STOP button on one processor ~n the configuration. If STOP is to be hit, both processors in the configuration must be STOPed. If neither prccessor has been manually stopped, there is protatly an hardware error associated with the SIGF function. 10 IBM VM/SP System Messages and Codes Explanation: A wrong or inconsistent allocation extent map was found on the FB-512 system residence volume during IPt. Issued by DMKCPI. 027 £~~~~!i~: An unrecoverable occurred or system input is Issued by module DMKSSP. I/O error incorrect. QEeratQ! Action: Correct the input/output error or the system input, and reload (via IPL) the starter system. Loader Wait State Codes 65 The loader (DMKLDOOE) is a service program that loads a CP, CMS, or RSCS nucleus, and produces a load maF. ~he loader loads the object modules (TEXT files) supplied with it, resolves CCi addresses, and resolves address constants. If the loader is terminated, one of following wait conditions is indicated in instruction counter: Code Vll1111' the the Action: Define a larger storage si2e for the virtual machine and reexecute the loader. 66 f1e~Bing A program check occurred. When loading a nucleus with a V=R area, the user area must include: loader + nucleus that is being loaded + the V=R area total storage requirement. !he area must be larger than this tctal to use the loader. (Refer to the VM/SP Planning and System Generation Guide. ) An SVC was issued. X'AAAAAA' A failing storage frame was entered while loading the CP nucleus. This is a hardware error. If the problem persists, contact your system support personnel. X'BBBEBB' A machine check occurred. X'CCCCCC' An I/O error occurred reader. X'FFFFFF' An I/O error occurred for the console (X'OO' contains the message UNRECOVERABLE ERROR), or the centrol card for changing the default I/O addresses for the printer or terminal is invalid (X'OO' contains the message EAt DEVICE CARD or INVALID DEVICE SPECIFIED). ~!El~B!!~: A duplicate type 1 ESD (External Symbol Dictionary) entry has been encountered. The loader cannot resolve this reference. This may be the result of a duplicate text deck in the input stream, or of having the same label in two different text decks in the same input stream. Close the printer to get the load map printed. Look at the load map to see which text deck and which entry are causing the problem. If you can correct the problem, do so; otherwise, contact your system support personnel. QE~!g1£! Actio~: A unit check occurred while the bootstrap routine was reading in the loader. X'999999' free storage Q]~rator 67 X'222222' Ex~l~Bati£B: There is no more available for the loader. ExlliBation: The "name" in the LDT (Loader Terminate) statement is undefined. Q]~~£! Ac!i£B: Verify that the name in the LDT statement is correct; if it is, make sure that it is defined as an entry point in the program to be loaded. 68 Ex£!~nation: The control section named in the ICS (Include Control Section) statement was not found by end of file. QE~!~!Q! on the !£ti£B: Verify that the ccntrol section name in the ICS statement is correct; if it is, make sure that the control section is defined in the program to be loaded. card 69 If the instruction counter contains X'999999', indicating an SVC wait state, examine the interruption code (the third and fourth bytes of the supervisor old PSi). The interruption codes (shown in hexadecimal below) indicate the error condition. 64 ExE!g~ati£B: The loader attempted to add another entry to the reference table, which would have caused the table to overflow. Since the reference table supplied by VM/SP is large enough to allow the CP nucleus to be generated, it must be assumed that the inclusion of local additions to the CP nucleus have caused the excessive references to be generated. ~~~!g!£! Acti£B: Increase the size of the reference table by changing the MAXREF equate field in the source code for the loader program, reassembling it, and then reexecuting the loader. Once the size of the reference table has been increased, error code 6A may occur. In that case, define a larger storage size for the virtual machine. If the problem persists, contact your system sUFPort personnel. Ex~lana!lsB: An error occurred during conversion of a value from hexadecimal to binary format. This can be caused by invalid input in one of the loader statements, or by an error in the loader. Q]~xs!2! !9!i£B: Validate the copy of the loader you are currently using against the copy on the original distribution tape. If the current copy is no longer valid, replace it. If the input in the statements is invalid, correct it. If the problem persists, contact your system support personnel. 6A The object modules being loaded are about to overlay the loader. Ex]~ion: !£!ion: Define a larger storage size for the virtual machine. To see which module was about to overlay the loader, QE~rator System Codes 11 close the printer to get the lead map printed. The last line of the load map indicates the last module tbat was leaded. 6C ~~]!gBati~: A failing storage frame was encountered while loading the CP nucleus. g]~atg~ Acti~: If the problem contact your support personnel. 6B ~!£l~BatioB: The object modules teing loaded are about to overlay an address between 0 and 100 (hexadecimal). This can eccur if the address at which loading was to start was changed by an SLC card. Q£~lQ£ !ctigB: Check the SLC card to make sure it does not specify an address between o and 100. If you must place data at an address in that range, de net do it ~ith the leader, but use a program to place the data there with a Move Character instruction after the loaded system has started execution. It is the responsibility of the loaded program to initiali2e tr.at Fart of storage. 12 persists, IBft VM/SP System Messages and Codes 6D Ex]!anati~: The loader is trying to release storage that is not on a doubleword boundary. This is an internal loader error. !£1ioB: Reexecute the copy of the leader that is in your reader. If the preblem persists, regenerate the sy~tem to be loaded and try to execute it aga1n. If the problem still persists, the current copy of the leader itself may be damaged; replace it with the loader on the distribution tape. If the problem still persists, contact your system support personnel. QE§f~1g£ RSCS Wait State Codes When RSCS enters a wait state, the RSCS operator is nctified via the CP message: DMKDSP450W CP ENTERED; DISABLED WAI! PSi issued to the RSCS operator's console. Using CP commands, the operator can disFlay the virtual machine's PSW. The three rightmost hexadecimal characters indicate the error condition. 001 007 !ZE!anation: A program check interrupt has occurred during initial processing, before the program check handler could be activated. This may be caused by a programming error or by an attempt tc load RSCS into an incompatible virtual machine. The latter case can occur if the virtual machine (1) has an incomplete instruction set, (2) has less than 512K of virtual storage, or (3) does not have the required VM/370 Diagnose interface support. The wait state code is loaded automatically during the initial loading and execution of the RSCS supervisor, DMTINI, DMTREX, DMTAXS, and DMTLAX. ~Z£l!BatioR: If no RSCS message was issued, a program check interruFt has cccurred during the execution of the program check handler. The probable cause is a Frogramming error. If the RSCS message Q]~~Q~ !£!i~: Verify that the RSCS virtual machine configuration has been correctly specified and that the "retrieve subsequent file description" functicn of DIAGNOSE code X'14' is supported. Dump the contents of virtual storage via the CP DUMP command. If the problem persists, notify your system sUFFort personnel. DMTREX091T INITIALIZATICN FAIlURE -- RSCS SHUTDOWN was issued, RSCS operation has been terminated because of an error in the loading of DMTAXS or DMTLAX. A dump of virtual storage is automatically taken. Verify that the CMS files D~TAXS TEXT and DMTLAX TEXT are correctly written and resident on the RSCS system residence device. If the RSCS message DMTREX090T PROGRAM CHECR IN SUPERVISCR -RSCS SHUTDOWN was issued, the program check handler has terminated RSCS due to a program check interrupt in other than a dispatched line driver. The probable cause is a Frogramming error. The wait state code is loaded by t~TEEX at RSCS termination or autcmatically during program check handling. 011 !1£1~~~~i~: An unrecoverable error has occurred during the reading of the RSCS nucleus from DASD storage. This may be caused by a hardware malfunction of the DASD device. It may be the result of (1) an incorrect virtual DASD device definition, (2) an attempt to use a system residence device unsupported by RSCS, (3) incorrect RSCS system generation procedures, or (4) the subsequent overwriting of the RSCS nucleus on the system residence device. The wait state code is loaded by DMTINI after an attempt, successful or not, to issue the message: DMTINI402I IPL DEVICE READ I/O ERROR £R~~g!~ Qpera~ jct!2~: If neither of the above two messages was issued, use the CP DUMP command to dump the contents of virtual storage. IPL to restart. If the problem persists, notify your system support personnel. Action: Verify that the RSCS system residence device has been properly defined as a virtual DASD device and that the real DASD device is mounted and operable. If the problem perSists, dump virtual storage via the CP DUMP ccmmand and notify your system support personnel. The RSCS system residence device may have to be restarted or the RSCS system may have to be regenerated. System Codes 13 CP Abend Codes SET DUMP CP 2. Format this spool file and CMS disk by issuing write it onto a SYSTEM OPERATOR ACTION VMEDUMP NOPRT When an abend occurs, the system oFerato~ must follow several steps to enatle the error to be corrected. 3. Write this disk file on tape by issuing the eMS command TAPE DUMP 1. Collect information about the 2. Collect status. 3. Recover from continue. information er~or. about the abend the system so processing can Unless the operator has issued the SET DUMP command and changed the default (which he should not do, generall~, the system is set for SET DUMP AUTO CPo When an abend occurs, this causes the dump to be written on disk as a spool file. This spool file is automatically spooled to the virtual reader of the operator who was designated at system generation time to ~eceive all dumps. This operator should then IPl eMS and issue the VMFD~rMP command (see the VML.§..!: Q~~g!Q~~ Guide). This formats the dump and prints it. This procedure should be followed for every abend. For problem determination, should save and submit: 1. The formatted dump. 2. The console sheet, as far IPL of the system. 3. The output of any Monitor at the time. the ope~ator back as the last program running If an APAR (authorized program analysis report) is to be submitted, the documentation provided with it should include, in addition to the above, a load map showing applied updates and resolved locations. You can obtain as many copies of the load map as you need if, at system generation time, you respond "RDR" to the prompting message: ROUTE LOAD MAP TO PRINTER OR READER? -RESPOND (RDRIPRT) This sends to your virtual reader a copy of the load map, which can be read in as a eMS file named, for example, LOAD MAP. When it is desirable to take a dump to tape and send the dump. to another location (for example, when submitting an APAR by mail), use the following procedure: 1. 14 Allow the dump to file by issuing be written to a IBM VM/SP System Messages and Codes You can then send this tape to another location, where the file can be recreated on disk using the TAPE LOAD command. spool The system usually reloads (via IPL) itself. If it does not, attempt to warm start. You may get errors from which you can recover; if so, correct the cause of the error and try again to warm start. If unrecoverable errors occur, clear storage and try to checkpoint (CKPT) start. If this fails, try to force start. If this also fails, as a last resort you must cold start the system. SYSTEM PROGRAMMER ACTION Figure 7 describes the reasons for each of the CP abend codes and discusses what the system programmer should do to locate and correct the error that caused the abend. r-----------------------------------Abend Code -------, Reason for A1:end Action API001 The global system lock I or the system operator's, VMBLOK lock could net bel obtained by the main I processor during IPI. I I I I , I I , I Check DMKLCKSY. If the attached processor owns the system lock, check R12 value in DMKLOKSY+4 to determine who obtained the lock. If the global system lock is held by the main processor, check the system operator's VMBLCK to see if the VMBLOK is locked by the attached processor. If so, VMLCCKER contains the base address of the obtainer at the lock and can be used to determine why the lock was ottained. ATS001 DMKATS was called to make a shared named system u~hared. However, the SHRTAELE associated with the shared page that was changed could not be located. The SHETAELE may have teen overlaid or the shared page that was changed was altered ty another virtual machine. If the SHETABLE was not overlaid, find out which virtual machine altered the shared page and why it was not detected. I I 1 1 ,1 1 1 1 1 1 1 ATS002 A shared page was A shared page was altered by I changed and the ccrresanother virtual machine without I ponding VMABLCK ceuld 1:eing detected. Investigate the I not be found. system routines that could allow I an undetected alteration of a I shared page. 1 -----I ATS003 During the unshare of a The SHRTABIE, SAVEWRK2 and I user from a shared SAVEWRK3 area of DMKATSs savearea 1 named system, DMKSNTEL (R13 contains address of saveI was brought back in to area) or ,DMKSNTBL (R4 contdins I recon struct the its address) have been altered. I SWPTABLE of the Investigate the routine that wouldl violator. The named allow alteration. I system could not be I found in DMKSNTEI. I 1 ATS004 During the unshare of a The system name table entry (R4 1 contains its address), the SYSOWN I user from a shared named system, the syslist or the RDEVBLOKs have been 1 tem volume containing altered. Investigate the routine I that would allow alteration. the named system could I not be found. 1 1 The CCRTABIE, SHETABIE, PAGTABLE, 1 ATS005 During the unshare of a user from a shared or ACCRETBL have been altered. 1 named system, a shared Investigate the routine that wouldl CORTABLE entry (R7 allow alteration. 1 contains its address) 1 was found with the I/O 1 lock bit on. I 1 Inspect modules that update ATS006 The resident page count I VMPAGES for the virtual machine. in the VMBLOK (VMPAGES) 1 does not match the num- I Check the routine to determine 1 ber of CORTABLE entries. I why it is inconsistent with the I I I number of COETABLE entries virtual machine. I L----___________________.____________________________ _ I assigned to this , Figure 7. CP Abend Codes (Part 1 of 23) System Codes 15 Abend Code I I I I Verify that R8 pOints to an I RDEVBIOK for a terminal. If it I does not, there is probably an I error in the calling program. I Identify the calling program by I means of the return address and I the base register in the save I area pointed to by R13. Then, at-I tem~t to identify the source of I the incorrect RDEVBIOK address. 1 Reason for Abend Action BLD001 R8 should contain a pointer to the RDEVEI0K 1 for the user's terminal. 1 DMKBLDVM attempts to 1 create and partially 1 initialize a VMBICK fcr I a user. DMKBLDVM abnor- 1 mally terminates if 1 R8 does not contain a 1 pointer to the user. I ---------------------------------1 BLD0021 Pages are being reExamine the dump and determine I I leased but the page why the page was released without I I invalid bit is not on I the page invalid bit turned on. I I in the page table entry.I I ------1 BLD003 A request was made to I R13 points to a save area. SAVER12 build a page table fer I contains the base address of the more than 16 pages. I module issuing the request. SAVER1 1 contains the beginni~g and ending I" address range of the page table 1 being built. Examine the calling 1 module to determine why R1 is 1 invalid. BLD004 BLD005 Examine R6 to ensure that it contains the address of a segment table entry. If it contains the address of a segment table entry, R13 contains the address of the module calling BLD. Examine this module to determine why this segment table entry has not been cleared. ------1 An attempt is being madel Examine R6 to ensure that it con- 1 to release a segment tains the address of a segment I whose page table has table entry. If it contains the I been migrated. address of a segment table entry, I R13 contains the address of a savel area. SAVER12 contains the base I address of the module calling BLD.I Examine this module to determine I why the page table was migrated or why the migration bit was not reset. CFG010 DMKCFGCL was called to perform an unsupported function. Supported values are: X' 01 ' LOAD SIS X'02' FIND SIS X' 04' PURGE SIS Identify the caller by the return address and base register in the SAVEAREA pOinted to by R13 to identify the source of the unsupported function request. CFP001 An I/O task is waiting for a RELEASE and the I CPEXBLOK for the waitingl task cannot be found on I the VRRCPEX queue. 1 I Check the storage dump Y. Determine why the virtual devic~ block is marked as waiting for access to the device, but not CPEXELOK exists on the VRRCPEX. Queue to resume the task. CKS001 The map for dynamic checkpoint was not allocated prior tc a call to DMKCKSPL. Figure 7. 16 The routine calling BIt has not cleared all the segment table activity before calling BLD. 1 I I I I The map should be allocated via a call to entry points DMKCKSIN or DMKCKVWM from DMKWRM. Check DMKWRM for called entry pOints and that they do allocate a map. CP Abend Codes (Part 2 of 23) IBM VM/SP System Messages and Codes r---------I Abend I Code Reason for Abend 1------------------The spool file 1 Action C~S002 identification in the map and in the checkpoint area do not match. DMKCKViM or DMKCKSIN did not set up the map properly, a call to DMKCKSPL caused the mismatch, or the SFBLOK was released but the map was not updated. I CKS003 1 I I 1 I CKV001 I I 1 No function was specified in the call to DMKCKSPL. Check SAV!RTN in the save area pOinted to by R13. This indicates which routine called DMKCKSPL with insufficient data. I I I 1 1 The map for dynamic .checkpoint was previously allocated prior to a call to DMKCKV~M. The map should not be allocated before DMKCKVWM was called. Map pOinter field is probably being overlaid. CKV004 A spool file to be deleted cannot be found on the system printer, punch, or reader file chains. The SFELOK for the file should haVE teen gueued previously on by DMKCKVWM when performing a CKPT start. Check for an error in thisl logic. I CLK003 The system TOD clock is not operational on the main processor or attached processor. The wait state can only be received when it is configured with an attached processor. Examine the CPABEND code in each processor's PSA to determine the unit receiving the clock error. Call IBM for hardware support to fix the clcck. CPI001 The RDEVBLOK for the DASD on which the SYSRES volume is mounted cannot be located, or the IPL volume is not the SYSRES volume. Verify that the serial number SYSBES volume serial number is the same as that specified in DMKSYSVL. If it is not the same, it may havE been altered by the LABEL option of the FORMAT fUnction of the standalone CP fcrmat program (IPL FMT or DMKFMT). Or the image of the same nucleus saved on the SYSRES been partially demay have stroyed and the SYSRES specification altered. Restore nucleus to the SYSRES volume from a backup copy and try to IPL. The SYSRES volume is specified in the SYSRES macro in the DMKSYS module. CPI002 A valid system directory file could not be located. CPI003 I The system TOD clock is I not operational. I Display the volume labels fcr all owned volumes. If the volumes do not contain an active directory pCinter, run DMKDIE (the standalone directory program) to recreate the system directory on an owned volume. If an active directory pointer is present in at least one volume label, verify that the device is cnline and ready before trying to IPL the system. Verify that a valid allocation reccrd is present on the volume containing the directory. Call IBM for hardware to fix the clock. support L----- Figure 7. CP Abend Codes (Part 3 of 23) System Codes 11 Abend Code Action CPI004 An error occurred attempting to page cut DMKVMI or DMKSYM !ry to determine whether the errors are being caused by the paging device or by the paging volume. If the device is failing, disable it and reload (via IPL) the s)stem; call IBM for hardware support. If the volume is failing, try reformatting it. If the error condition recurs, discontinue using that volume and call your system support personnel. CP0003 DMKACRO returned a non- I zero condition cede to I DMKCPO. A VARY CFFLINE I PROCESSOR command was I issued in MP mode; prierl to accepting the VARY I OFFLINE command as I valid, DMKCPO verified I that online paths weuld I still exist to all I mounted system-owned I devices. Between that I time and the call te I DMKACRCO, the configura-I tion has changed and a I path has been lost. ihel system cannot continue I operation if there are I not paths to all I system-owned devices. I Examine the storage dump. From the list of system-owned devices located by DMKSYSOW, find the RDEVEIOKS for these devices. The online path information in RDEVP~HS may be overlaid. CPP001 The user page count in the V~BLOK was incorrectly decreased to less than zero. CPP002 I Examine the storage dump. The I VMBLOK has probably been overlaid. I During the VARY procesExamine the storage dump. The sor offline function, SHR~ABLE or DMKSNTBL has probably DMKSNTBL was brought been overlaid. back in to reccnstruct I the attached processor'sl SWPTABLE for shared I pages. The named system I could not be found inl DMKSNTBL. I CPV001 The resident page ccunt I in the VMBLOK (VMPAGES) I is reduced to a negative I value. I I I Inspect modules that update VMPAGES for the virtual machine. Check the routine to determine why it is inconsistent with the number of CCRTABLE entries assigned to this virtual machine. CQP001 DMKSCNRA was called and unable to determine the device address in cuu format from real device I block address in R6, R7,1 and RS. I I Examine the storage dump. DMKSNRA returns an error if it cannot find the address of the real contrel unit block from the real device block. ~he control unit block addr~ss in register 7 is probably invalid. CVT001 The system TOt clock is in error or is not operational. Call IBM for hardware support to fix the cleck. Figure 7. 18 -------, Reason for Abend CP Abend Codes (Part 4 of 23) IBM VM/SP System Messages and Codes I I I I I I I I I I I I Abend Code Reason for Abend Action ---------------------------------------------------------------------------DRD001 The device code index Verify that the contents and or- DSP001 in the compressed tASD address for the system dump file points te an RDEVBLOK for an invalid DASD. The valid DASEs are 2305, 2314/2315, 3320, 3330, 3340, 3350, and 3370. der of the owned list have not been altered since the dump was taken. If these fields have not been altered, the SFBLOK for the dump file may have been destroyed. !he owned list is specified by the SlSOWN macro in DftKSYS. During I/C interruption, unstack, and reflection, DMKSCNVU could not locate all of the virtual control blocks for the interrupting unit. The integrity of the user's virtual I/O configuration has probably been violated. The unit addresses or indexes in the virtual control blocks are in error, or the virtual configuration has been altered by ATTACH/DETACH while I/O was in progress. Check for a device reset failure in D~KCFFRD. DSP002 The dispatcher (DMKtSP) is attempting to dispatch a virtual relocate user whose shadow segment tables or virtual extended centrel register 0 are invalid. Most likely, a free storage violation has occurred. First look at the DMKFRV and DMKVAT modules. Examine the real, virtual, and shadow translation tables for consistency of entry si2e and format. Also compare page and segment si2e. DSP003 The interval timer was not incremented properly. This is most likely a hardware error. The dispatcher tests for interval timer errors and abnormally terminates if such an error occurs. Results would be unpredictable if CP continued when the interval timer was in error. Check the timer fields in real storage. !he value of the real interval timer is at real storage location X'SO'. The dispatcher loads the value of the real interval timer in real storage location X'S4' when a user is dispatched. The value of the real interval timer is loaded into real storage location X'4C' when an interrupt occurs. If the value stored at X'4C' is not less than the value stored at X'S4', the dispatcher abnormally terminates. Check the routines that control the value of the time fields at X'4C', X'SO', and X'S4'. DSP004 While tracing SICs or I/O interrupts, the virtual device was detached. NOW, the VDEVBLOK cannot be found. Examine the oFerator's console sheet and the user's terminal sheet to see who detached the device. Warn the person responsible that devices should not be detached during I/O tracing. DSP005 During extend, a block is found to be unstaeked, but the lock for the associated VMBLCK is not available, or count of priority CPIXBLOKs in a VMBLOK is less than 0, but no priority CPEXBLCK is R1 contains the VMBLeK address at the time of the abend. Check VMLOCK to see if the VMBLOK is locked by the other processor. If this is the case, V!lCCKEB gives the base address of the obtainer of the lock and can be used to determine why the lock was not released. If the VMEIOK is not Figure 7. CP Abend Codes (Part 5 of 23) System Codes 19 ----------, r- I Abend I Code Reason for Abend Action I I DSP005 I found for the virtual I (cant.) I machine, or during , , post-extend processing, I , either the expected , , processor-related I , priority CPEXBLOK is , , not found or the lock , I for the associated I I , VMBLOK is not available., locked by the other processor, check VMPRRCT, (the count of pricrity CPEXBLOKs). If this is nonzero but there are no priority CPEXBIOKs on the dispatcher's stack, this field has probably been overlaid and other methods must be used to determine the cause of the overlay. 1----------·--------------------------,DSP006 DMKDSPRU, the run-user , Use the trace table to help entry to the dispatcher , determine the caller of was entered when the I DMKDSFRU. system was not is , attached processor mcde.1 , I I 1 EXT001 A serial signal reguest has been received and the global system lock is not held. In the PSA of the a£ending processor, the work/save area SIGSAVE contains the return address of the caller of DMKEXTSP, this address is at offset X'8' into SIGSAVE. At offset 0 into SIGSAVE is the base address of the caller. FREOD1 The size of the block being returned (via RO) is less than or egual to D. Using FREER14 and FEEER12 in the PSA, identify the CP module releasing the storage. Check for an error in calculating the size of the block or for a modification to the stored block size for variable-size blocks. FREDD2 The address of the free storage block being returned matches the address of a block already in the free storage chain. Identify the progxam returning the storage by means of the return address and base registers (FREE14 and FREE12 in DMKFRE's save area in PSA). The most common cause of this type of failure is a module that returns a free storage block but fails to clear a pointer to the block that has been saved elsewhere. All modules that return blocks via a call to DMKFRET should first verify that the saved pointer is ncnzexo; aftex returning the block, any saved pointers should be set to zero. FREDD3 The address of the free storage block being returned overlaps the next lower block on the free storage chain. A free storage pointer may have been destroyed. Also, the module releasing the lower (overlapped) block may have retuxned too much storage. Examine the lower block and determine its use and former cwner, or identify the program returning the storage by means of the return address and base registers stored (FREER14 and FREER12 in DMKFRE's save area in PSA). The most common cause of this type of failure is a module L--- Figure 7. 20 CP Abend Codes (Fart 6 of 23) IBM VM/SP System Messages and Codes Abend Code ------------------------------, Reason for Abend Action that returns a free storage block but fails to clear a pointer to the tlock that has been saved elsewhere. All modules that return tlocks via a call to DMKFRET sheuld first verify that the saved pointer is nonzero; after returning the block, any saved pointers should be set to zero. FREOO 3 I (cant.) I I I I I I I I FRE004 The address of the free storage block being returned overlaps the next higher tleck en free storage chain. A free storage pcinter may have been destroyed. Also, the module releasing the higher (overlapped) block may have returned too much storage, or the module may be attempting to release storage at the wrong address. FRE005 A module is attempting to release storage in the resident system nucleus. A module is Frobably attempting to release location o. Check for the mcdule picking up a pointer to the free storage tlock without first testing the pcinter for O. Use FREER14 and FBEER12 in the PSA to identify the module. FRE006 A module is reguesting a block of storage whose size (contained in R 0) is less than or egual to zero. I Using FREEB14 and FREEB12 in the 1 PSA, identify the module. Check 1 fer an error in calculating the I bleck size. Improper use of the I halfword instructions ICM and I STCM can cause truDcation of high 'I erder bits that results in a calI cUlation error. FRE007 A module is attempting to release a block of storage whose address exceeds the size of real storage. A free storage pointer may have been destroyed. Attempt to identify the owners of the free storage tlocks adjacent to the one containing the pointer that was destroyed. Check for moves and translation where initial counts of zero have teen decremented te minus 1, thus generating an executed length code of XIFFI, or an effective length of 256 bytes. FRE008 The address of the free storage block being returned matches the address of the first block in the subFcol for that size. FBE009 The address of the free storage block being returned matches the second block in the subpool for that size. Identify the program returning the storage by means of the return address and stored base registers (FREER14 and FREER12 in DMKFBEls save area in the PSA). !he common cause of this type of failure is a module that returns a free storage block but fails to clear a pointer to the block that has teen saved elsewhere. All modules that return blocks via a call to DMKFRET should first verify that the saved pointer is nonzero; after returning the block, any saved painters should te set to zero. L- Figure 7. CP Abend Codes (Part 7 of 23) System Codes 21 Abend Code FRE010 Action Reason for Abend A program is attempting to extend free storage while storage is being extended. This can be caused by I/O interruptions or channel programs involving channels other than channel O. If the storage requests that the abend are due to channel activity, place the device involved on channel 0, which is disabled during free storage ex- cau~ed ten~ion. FRE011 A CP m09ule has attempted to return a block of storage that is in the user dynamic paging area. Identify the program returning the storage by means of the return address and stored base registers ~FREER14 and FREER12 in DMKFREE's save area in the PSA). The common cause of this type of failure is a module that returns a free storage block but fails te clear a pointer to the block that has been saved elsewhere. All modules that return blocks via a call to DMKFRET should first verify that the saved pOinter is nen2ero; after returning the block, any saved pointers should be ~et to 2ero. FRE012 An extend was entered while extending. !he free storage extend buffer is unavailable. The system workload reguires more I free storage than is available. I Either: (1) Reassemble DMKSYS withl a larger value for FREE in the I SYSCCR statement and reinstall thel CP nucleus, (2) Restrict th~ I number of users on the system, or I (3) Add more real sterage. I FRE014 DMKFRE must defer satisfying a free storage reguest when it is necessary to call DMKPTRFR and the global supervisor lock cannot be obtained. T~e free storage extend buffer reserved for this purpose is not available. Examine the internal trace table and storage dump to determine why the free storage extend buffer was net previously replenished. GRC001 DMKGRCUP was called to generate the order reguired to update the 3270 screen, but the CONTASK supplied was too small for the data stream required. HPS001 A routine process was called to a device that was not a logical device. I I The registers at entry to I DMKGRCUP are saved in BALRSAVE; I the calling module can be I identified from BALR14, the input I CON!ASK address is in BALR6 and I the input parameters in BALR2 I define the type of screen updatingl to be done. See the GRTBLOK macrol for definitions of these parame- I ters and of the screen orders thatl are used. 1 ---------------------------11 Check the trace for activity to the device. I I 1 I Figure 7. 22 CP Abend Codes (Part 8 of 23) IBM VM/SP System Messages and Cedes Abend Code Reason for Abend Action HV0001 The user pointed to ty R11 issued a DIAGNOSE instruction while attempting to format the I/O error, channel check, or machine ChECk recording areas; the SYSRES device tYPE is unrecognizable. ~he Rt~VBLCK for the SYSEES device was probably destroyed, or a volume with the same serial number as the SYSR!S volume was mountEd. If a volume with the same serial number was mounted, check the A~TACH processing in the DeKVDB routine. HV!001 The user pointed to ty R11 issued a DIAGNOSE instruction while attempting to format the I/O error, channel check, or machine check recording areas; the SYSRES device type is unrecognizable. ~he RDEVBLOK for the SYSRES device was probably destroyed, or a volume with the same serial number as the SYSRlS volume was mounted. If a vo~ume with the same serial number was mounted, check the ATTACH processing in the D~KVDB routine. -----1 I I 1 I I I 1 I I ----I ~he ICELOK may have been returned 1 (via DMKFRET) or destroyed. I Verify that the IOEIOK was valid I and use the IOBLOK and RDEVBLOK I to determine the last operation. I I 1--------------------------------------------------The caller is trying I 105001 , I to reset an active lOBLOK from the RCHELOR I queue, but that IOEICR I contains an invalid I address. I~------------------DMKIOS is attempting tc I IOS002 restart an IOBLOK from the RCHBLOK queue, tut I that IOBtOK contains 1 an invalid address. I , The ICELOK may have teen returned (via DHKFRE~) or destroyed. Verify that the IOBLOK was valid and use the IOBLOK and RDEVBLOK to determine the last operation. 105003 DMKIOS is attempting to remove an IOBleK from a queue, but that IOELOR contains an invalid address. Register 2 points to the RCHBLOK, ECUEICK, or EDEVBLCK from whose queue the IOBLOK is being removed. Register 10 Foints to the ICBICR. Use the CP internal trace table to determine which module called DMKIOS twice to start the same IOELCK. 105004 DMKIOSHA was called to halt I/O associated with an IOBLOK pointed to by register 10. However, register 10 pOints to an IOBLOK that is marked as a mini-lOB. A mini-lOB is not allowed to exist outside the control of DMKIOS. Examine the trace table in the storage dump and determine what routine built and called DHKIOSHA with IOBLOK marked as a mini-lOB That routine is in error. IOSOOS DMKIOS was called to perform I/O for a device USing fixed path I/O. lOS is to bypass using any alternate path to the device. ~he real device block address .that was passed in B8 is not the real device address in the IOBRADO field. ________ __ L-__ ~ ____ Figure 7. ---------------------------------ExaminE the trace table and determine who called lOS requesting the fixed path I/O. Either an incorrect call was made to D!RICS, BS did not point to the correct real device block, or the lOB that is pOinted to by R10 was overlaid. ~ CP Abend Codes (Part 9 of 23) System Codes 23 --, 1 Code Reason for Abend Action 1 1 ~~-----~~----------------------------------------105006 OMKIOS was called to Examine the trace tatle and 1 perform I/O to a device storage dumF to determine what 1 that is logically onroutine has incorrectly altered 1 line, but for which either RDEVDISA or RDEVPTH5. I there is no available 1 path online. That is, 1 the online path status 1 in RDEVpTHS does not I match the device status I indicated by RDEVDISA. 1 ~-----~~---------------------Abend 105007 In attempting to start an 1/0 request, lOS must remove all alternate path lOBs that exist on paths to the device except the one that is about to be startea. In scanning the chain of these 10E'S, two were not marked as mini-IOE, indicating two real requests for the same I/O. Examine the trace table to determine the segU€DCe of events that led to two lOBs being passed to lOS and then having tcth lOBs occur on the same reguest chain. --~----~~--~---------- 105009 105010 1--.. . . . . . . . . -IUA001 Figure 7. 24 I A Start I/O is attemFtedl Examine the dump to determine 1 for a sense CCW after a I why there is no IDERBLCK address I short busy sequence frcml in ICEIOER. 1 a 3270. This causes thel I rOELOR to be queued. Thel I 10E5B5IO is on and therel I is no IDERELOR address I I in IOB10BR. I I "------------I In attempting to restartl EXamine the CP trace table to find pending I/O requests I uFon which channel, control unit, after an I/O interruFt I and device path the I/O interrupt has made an I/O unit I occurred. Examine DMKICT and available, bMKICS finds I DMKICS logic to see why DMKI05 is that the current RCBELOKI trying to restart I/O on a does not belong to the I different channel. If the trace current processor. I table shows that DMKIOS received I ccntrel as a result of a call, I examine DMKIOS logic to see how I its internal indicators were I changed to show entry due to an I I/O interruFtion. . . -------------------------1 A program check occurredl on the last system-ini- 1 tiated IUCV function. 1 1 I 1 I Locate the last lUCY instruction frem the trace table and determine the type of lUCY function requested. Determine what lUCY exceptions are generated by that lUCY function (see the !~~R ~I§!§!-g~2~~g~~§I§_Qyig~)· CP Abend Codes (Part 10 of 23) lEft VM/SP system Messages aDd Cedes 1 I 1 1 I I 1 • • J Abend 1 Code Reason for Abend Action 1 1 I....' -----------------------------------1 1 IUC001 The Path ID of the target communicator con1 tained inconsistent or I conflicting status 'flags. I i 1-'----------------I !UC002 I I I 1 1 i IUC003 t I 1 I 1 1 I IOC004 1 1 1 t 1 A pending connection fori the path specified couldl not be found on the I pending connection I chain. I Locate the path description for 1 the specified path ID. Then locatel the corresponding path ID for the 1 target communicator and determine 1 why the entIY has been marked 1 invalid. , I Locate the path ID that was spe- , cified to determine why no corre- I sponding entry can be found on the, pending connection chain. I I , An error was enccunteredl locate the message tlock that was I on a IOCV Reject fOI a I to te rejected or purged and de- I ----I message that is supposedl to be valid but was not I found on the message I queues. I termine on which gueue it should te located. Search the message queue to determine why i t could not te located. I An error was encountered I on a IUCV Purge for a I message that is supposed I to be valid but was net I found on the message 1 queues. 1 locate the message tlock that was to te rejected or purged and determine on which queue it should te located. Search the message queue to determine why i t could not be located. I 1------------------------------------------1 IUE001 On a Receive or lest Locate the 1 I 1 1 1 I I 1 1 1 IUG001 1 , Completion, IUCV has located a message block on the queue with the specified message ID. The path ID in the I message block is invalidl (as returned from I DMKIOAPD) • I I 1 , I I I I 1 I message block with the specified message It and determine the path ID that it contains. Search the path description segment for the corresponding path description and determine why the entry has been marked invalid. I On a Reject, IUCV has 1 located a message block I on the queue with the 1 specified message ID. I The path ID in the I message block is invalidl (as returned from I DMKIUAPD) • I I tUG002 No room was found for a new path in the CCT. When the CCT was built (by the Declare Euffer function), enough roem was allocated for all possible connections. Compare the number of current con-I nections with the number of con- I nectiens frem the directory. One I possible reason for this error is I if the directory is modified dy- 1 namically and the connection limitl for a user is increased, the space that was allocated for CCT is no lenger large enough. teK001 An OBTAIN request has been made for a lock that is held by the requesting processor. R1 contains the lockwerd address at the time of the abend. In the PSA of the abending processor, the savearea LCKSAVE contains the return address of the caller at offset X'38' and the entry point address into DMKLOK at offset X'3C'. Figure 7. CP Abend Codes (Part 11 of 23) System Codes 25 .--- I Abend I Code , , LOK003 I I , , I I I I Reason for A1::end A RELEASE has been issued for a lock that is not owned by the reguesting processor. DMKLOK does not get control for a RELEASE reguest. Use the supervisor old PSW in the PSA of the abending processor to identify the module where the error occurred. R1 contains either the lockword address (in the case of a global lock) or the address of the VMBLCK (in the casel of a VMBLOK lock) at the time of I the a1::end. I Automatic Processor Recovery (DMKMC'IPR) haE received control on the main processor without the global system lock and the lock could net be obtained. Check DMKLCKSY to determine if thel system lockword has been overlaid. I If the attached processor owns thel leck, check the R12 value in I DMKIOKSY+4 to determine who I ottained the lock. The system I should not be in autematic I processor recovery if the attached I processor was in sUFervisor state., , , MCT001 ! , I ! I ! I ! Action I MHC001 I This is not an error condition. I If the problem persists, contact I your system support personnel. , I Note: Possible ccndi- , tIon codes are 0 and 2. , A condition code of 2 I indicates that the MSSF I is busy. This condition I should not occur since I CP never issues a reI guest if an interruFt I for the MSSF is pending.! MHC002 An unsolicited MSSF interrupt has been received. A MSSFCALL Diagnose instruction was issued and a nonzero conditicn code was returned. I 'Ihis is an error condition, if thel protlem persists, contact your I system sUPFort personnel. I Note: Unsolicited MSSF Interrupts should net occur. NLE001 I I I , During execution ef a Correct the RDEVICE macro speciNETWORK DUMP command, fying the 3704 or 3705, reassemor during an autematic tIe the DMKEIC module, and regendump of a 3704 or 3705, erate the CP nucleus with the the system detected suf- corrected nodule. ficient DASD sFool space to contain the information from the 3704 or 3705. 'The MODEL operand of the RDEVICE macro descri1::ing the 3704 or 3705 was not specified correctly. VM/SP determines the storage size of a 3704 or 3705 by the medel specified on the RDEVICE macro. L----________________________________________________________________ --J Figure 7. 26 CP Abend Codes (Part 12 of 23) IBM VM/SP System Messages and Codes r- I Abend I Code I I PGS001 I I I I I PGT001 Reason for Abend Action The resident page ccunt I in the VMBLOK (VMPAGES) I is reduced to a negativel value. I I I Ins~ect module that update VMPAGES fo~ the virtual machine. Cbeck the ~outine to determine why it is inconsistent with the numbe~ of CORTABLE entries assigned to this virtual machine. The number of cylinders in use stored in the allocation block (ALOCBLOK) is less than the maximum but the DMKPGT module was unable to find available cylinders. Inspect the chains cf paging and spooling allocation blocks anchored at RDEVPAGE and RDEVRECS on the RDEVEICK for the device in guestion, and verify that a cylinder allocation block (RECEIGK) exists for each cylinder marked and allocated in the AICCEICK. If RECELOKs for some cylinders are missing, it is possible that the bit map in the AIGCEICK has been destroyed. If all cylinders are accounted for, the updating of the count field is in erro~. For FB-512 devices (DMKPGT is allocating onl on an FB-512 device) the number of pages in use (ALOFUSED) is less than the maximum (ALOFMAX), but DMKPGT could not find a RECBLOK containing an available page. Ins~ect the extents of TEMP space stored in the ALOFELCK. The ALOFELCK has a 24-byte extension for each extent of TEMP space ~ages on the volume. Anchored in this extension are the RECELOKs that describe the availability of each ~age within this extent. InsFect each RECBLCK to see if all the Fages in each RECELOK are used. It is possible that the RECELCK chain or the AIOFBLOK extensicn has been destroyed. If all pages are accounted for, the numte~ of available Fages in all BECELCKs should add up to the number of available Fages stored in the ALCFBICK extension (ALCFNUMA). Also, the ALCFNUMA fields of all ALOFELCK extensions should agree with the number of available pages described in the ALOFEIOK root (ALOFMAX-ALOFUSED). If these ccunt fields do not agree, the updating logic in DMKFGT is in error. L--- Figure 7. CP Abend Codes (Part 13 of 23) System Codes 27 i Abend code Reason for AtEnd PGT002 I The count of pages I in a page allocation I block (RECBlOK) is less [' than the maximum tut I the D~KPGT module was f unable to find availI able pages. I I I I PGU001 The DASD page slot being released is net marked allocated. Action 1 1 ------------------------------1 If the RECElCK in guestion is in 1 use for ~aging, then locate a 1 SWPTAElE entry for each page 1 represented by this RECElOK. I FB-512 BECBIOKs describe the rangel of page numters in fields RECSTRT 1 and RECEND. However, if the pagesl are in use for spooling, it is I possitle that the RECBIOK itself 1 bas been destroyed or that the uP-I dating of the use count is faulty. I Identify the module attempting to release the page by means of the caller's return address and base register stored in BAlR14 and BAlB12 in the BALRSAVE save area in PSA. locate the source (control blcck or SiPTABLE entry) of the DAst address being released to verify that they have not been destroyed. If the tASt page is in a spool file, it is possiblE that the file or the RECElCK chain has been incorrectly cbeckpointed and warmstarted aftEr a system shutdown or a system crash. --~--~------------------------- PGU002 The dummy RECEIOK indicating the spooling DASD pages on the cylinder that are to be released contains a page count greater than the number of pages allocated on the cylinder. ~he spool file pointers may have been destroyed while the file was being processed, or the allocation chain may be in error. A cold start may be necessary. If feasitle, use the DASD dump/ restore program to print the DASD areas containing the affected file, and try to locate the incorrect pointers. --~---------------- PGU003 Figure 28 7~ I~~ A module is trying to release a DASD pa9E slot on a cylinder or FE-512 extent for which I no page allocation block (RECBIOK) exists. Use EAlR14 and EAlR12 in the BAlRSAVE save area of the PSA to identify the module attempting to release the page. For count-keydata tASD, verify that the DASD cylinder address is valid for the device in guestion. If it is and the rest of the DASD address is I valid, verify that the cylinder ~sl in the dynamically allocatable I area. For FB-512 DASD, verify I that the page number is valid and 1 in the dynamically allocated area.1 If these restrictions are met, thel the DASD page must have been used 1 ________________ by mere than cne user. Ii CP Abend Codes (Part 14 of 23) Vft/SP System ftessages and Codes Abend Code PGU004 ---------------------,I Reason for Abend Action I The last DASD page slot ~he AIGCBICK has Frobably been in a RECBLOK has been destroyed, or the chain pointer deallocated but the bit in the RDEVELCK is in error. representing the cylinder in the cylinder allocation block (ALOCBLOK) is not currently set to ene, indicating that the cylI inder was not allocated., 1-------------1 I I I I I Note: Because allocation-of pages on an FE-512 device does not use this bit map, this code is not applicable 1 to FB-512 devices. , , , , , I PGU005 The system's virtual storage buffers have been exhausted because of an excessive number of open spool files. Beguest USErs to close all spool files that are no longer active. PGU006 I I I I I I I I I I I A module is trying to release a page of virtual storage in use by the VM/SP control Frogram that has not been marked allocated. Use EALR14 and EALR12 in the EALRSAVE save area of the PSA to identify the module attempting to releaSE the page. Locate the control block containing the virtual Fage address that is being released. It is possible that the address has been destroyed, or a pointer to a virtual page has been retained after the page was I destroyed. 1------1 1-------------------- (opera- I Examine thE old PSi and identif~ control, the module baving the program , I program. I check. I I I PRG002 Program check (privi- I leged operation) in the I I I control program. I I I I PRG003 Program check (execute) I I I in the control prcgram. I I PRG001 1 Program check I 1 tion) in the 1-------------------------1 I PRG004 I Program check I J tion) in the I I program. (protec- I control I I 1------------------1 I PRG005 J I I J I I I PRG006 I I I I PRG007 I 1 I PRG008 1 1 (address- I control I I I program check (specifi- I cation) in the contrcl I program. I I Program check (data) in I the control program. I Program check ing) in the program. I Program check (fixed- I point overflow) in the I control program. I '-- Figure 7. CP Abend Codes (Part 15 of 23) SYstem Co4es 29 r I Abend I Code Reason for Abend Action 1 I PRG009 I I I I PRG010 I Program check (fixedExamine the old PSi and identif] point divide) in the the module having the program control program. I check. -----1 Program check (dEcinal 1 overflow) in the ccn- I I trol program. 1 I ------1 1 PRG011 program check (decimal I I divide) in the control I I program. 1 I -----1 1 PRG012 Program check (exFonen- I 1 tial overflow) in the I 1 1 cOntrol program. 1 1------------------------1 1 PRG013 I program check (exFonen- I I 1 tial underflow) in the I 1 1 control program. 1 1----1:-------------1 1 PRG014 1 Program check (signifi- 1 1 1 cancel in the ccntrol I I 1 program. 1 1 1 I PRG015 Program check (floating-I 1 point divide) in the 1 control program. 1 I 1 1 1 PRG016 Program check (segment) 1 I in the control prcgram. 1 1 1--------------------1 1 PRG017 1 Program check (paging) 1 1 1 in the control Frcgram. 1 1------------------1 1 PRG018 1 Program check (transla- 1 I I tion) in the control 1 1 1 I program. 1------1 1 PRG019 1 Program check (sFecial 1 I 1 operation) in the con- 1 1 1 trol program. 1 II PRG254 A translation specifiIf the set ef translation tables I cation exceptien has peinted to by BUNCR1 is correct, 1 been received for a a hardware failure has occurred, 1 virtual machine that is Fcssitly with dynamic address 1 not in extended control translation. Otherwise, call IB! 1 I mode. I fer softwaJ:e support. 1 - - - - - - ·- - - - - - - - - - - - - - I PRG255 I A PER (program event 1 Retry the program causing the er1 I recording) has been re- 1 ror; if the problem persists, 1 1 ceived for a virtual 1 call IBM for software support. , I machine that is running 1 1 I with PER disabled in I I I its virtual PS~. I --------I 1 PSA002 The "System Restart" Examine the resulting abend dump I console key was Fressed.1 for a dynamic picture of the I The operator normally system's status. 1 takes this action when 1 an unusual system conI dition occurs, such as 1 a system loop er slow 1 machine operation. '-- Figure 7. 30 CP Abend Codes (Part 16 of 23) IBH VH/SP System Messages and Codes 1 I 1 t Abend Code Reason for Abend Action PSA003 An unrecoverable DASD error occurred on a I paging device. Or pagingl device is offline. 1 1 1 1 I Check the trace table for a start I/O in the paging device with a condition code 3 to verify device is effline. If offline, vary paging device online. Or check the unit address at hex 'B9' in the PSA to find paging device in error. This is a hardware error. PSA004 A CPU timer interrupt occurred either while I the system was in a wait state or when an enable window was opened. Check CPS1A!US in the PSA to determine whether the interrupt occurred while in a wait state or during an enatle window. If the interrupt occurred ~hile in a waitl state (CPWAIT on in CPSTATUS), thel timer value at the time of the I interrupt is stored in the PSAs I WAITEND. If the interrupt occurred I during an enable window (CPEX on I in CPSTATUS), the timer value is I stored in the first two words of I the PSAs TEMPSAVE. If the timer I value is negative, it is probably I a Fregramming error. Try to I determine why the timer was set I to a negative value. If the timerl value is positive, ottain hardwarel support to determine why the I interrupt occurred. 1 -----------------------------------------------------------------1 A program is attempting 1 Use the values of register 14 and 1 PTR002 PTR003 to unlock a page frame I register 12 at the time of the 1 whose address exceeds 1 abend to identify the module I real storage size. 1 1 attempting to unlock the page frame. Check for the ·source of the 1 1 invalid address. ----I A program is attempting 1 to unlock a real stor- 1 age page frame whose I CORTABLE entry is net 1 flagged as locked. 1 PTR004 The lock count in the CORTABLE entry for the page frame being unlocked has been decremented to a value that is less than O. Check the routines that update the leck ceunt field and CORTABLE entry. PTR007 DftKFRE requEsted a page for fixed free storage but DMKPTR determined that there were no pages left in the dynamic paging area. Examine the dump fer ene of the fellowing conditions: 1. Excessive amounts of free sterage have been allocated by CP and not released via DMRFRET. Look for blocks of identical data and determine which modules built that data. Figure 7. CP Abend Codes (Part 17 of 23) System Codes 31 r- I Abend I Code Reason for Abend PTR007 I (cont.) I 1 Action block of storage greater than 4096 bytes was requested. Beguests for large blocks of free storage reguire contiguous pages from DMKFTR and as a result have a higher probability of failure than requests for one page or less. If possible, change the application to reduce the size of storage requests. Otherwise, schedule the application when storage is less fragmented. 2. A I 1 1 1 1 1 I 1 I 1 1----1----· I PTR008 1 A CORTABLE entry on the 1 1 free list points to a 1 1 valid PTE (page tatle I 1 entry), but the page is I 1 allocated. J 1 Pages on the free list should not contain valid PTEs. Examine the dumF to determine which module called DMKFlRFR. lhe module that called DMKFTRFR probably contains an error. The count of the numrer of resident reserved pages was incorrectly decremented.so that the count is now less than 1 zero. lhe field CMRP~RRC contains the number ~f reserved pages. DMKFTERC must always be less than D~RrSfNP. Check the routines that update these two count fields (DMKDSPNP and DMKP!EEC). 1 PTR011 1 A CORTABLE entry to be I 1 placed on the free list I 1 points to a valid P~E 1 I (page table entry), but I 1 the page is allocated. I I An abend occurs trying I I to honor a deferred reI 1 quest. Pages to be put on the free list should not contain valid PTEs. Examine the dump to determine why the page was not marked invalid before the call to CMKPTRFT. I I 1 PTR010 I I I I I 1------1--------------------- I I PTR012 I I 1 I I 1 PTR014 I I I I I I I 1 PTR015 1 1 32 I I I I I I I I I I A CORTABLE entry to be placed on the free list points to a valid PTE (page table entry), tut the page is allocated. Pages on the FREELIST should nct contain valid PTEs. Examine the dump to determine which modulel called DMKFTRFT, it probably I contains an error. I DMKPRTFT was called to put a page on the FREELIST that is already cn the FREELIST. A page that is already on the I FREELIST should not be specified I in a call tc DMKPTBFT. Check the I FREELIST and flush list for valid-I ity. Restart the system and, if I the problem persists, call IBM fori software support. I ---I Examine the storage dump to deter-I mine either how the page was I placed on the flush list without I a PTE pointer or what module sub- I seguently modified the core table I entry. I I Inspect modules that update I VMPAGES for the virtual machine. I Examine the routine to determine I why it is inconsistent with the I number of CORTABLE entries I assigned to this virtual machine. I The core table entry fori a flush list page does I not contain a page tablel pointer. I I I 1 I I I The resident page count 1 PTR018 in the VMBLOK (VMPAGES) I 1 is reduced to a negativel I value. I I 1 I L--__________________ _ 1 I Figure 7. I 1 CP Abend Codes (Part 18 of 23) IBM VM/SP System Messages and Codes I , r-- I Abend I Code I Beason for Abend 1------------ I PTB021 I PTB was entered without I I the global system lock, I I but the VMBLOR already I I has its deferred task I I I stacked. Some error hasl I I occurred in failing tc I I I obtain the global I I I system lock. I I An unrecoverable llC I BNH001 error occurred during I read or write for the I 3704/3705. Status I indicates program I failure. I Action Exa&ine the SAVEABEA pointed to by B13 to determine why PTB was called without the global system lock. Fetry. If the Frotlem persists, ensure that the 3704/3705 and channel hardware are functioning correctly. BNH002 A response that should not occur was received from the 3704/3705 control program. Verify that the 3704/3705 NCP is oFerating correctly. Use the NETWCER TRACE command to determine the exact cause of the resFonse. BPAOO 1 The virtual address supplied to DMKRPAGt is outside of the virtual storage being referenced. BPA002 The virtual address supplied to DMKBPAP! is outside of the virtual storage being referenceCi. the virtual storage belongs either to the user whose VMBLOK is pOinted to by B11 or, if R2 in the SAVEARIA indicates a PABM of SYSTEM, to the system VMBLOK. Identify the calling program by means of the return address and base register saved in the SAVEAEEA pointed to by B13. If the virtual address wa~ obtained from the system's virtual storage, examine the virtual page allocation routine, DMKPTBVG. 'If the virtual page refers to a user's storage, attempt to identify the routine that generated the incorrect address. Verify that the VMSIZE in the relevant VMBleK reflects the correct storage si2e for the system or user being referenced. BPA003 The user page count in the VMBLOK became negative. A mcdule has attemFted to release more Fages than it originally received. The module that last called DMKBPA is probably the module in error. SCH001 The total number of interactive users plus batch users in the scheduler's gueue is less than zero. A counter was Frobably decremented incorrectly. the field SCBN1 is the count of the number cf interactive users and the field SCHN2 is the count of the number of batch users. Check the routines that update these two count fields (SCHN1 and SCHN2) to determine why their sum was negative. SCH002 A call was made to DMKSCHDL that resulted in an attempt to droF a user from a runatle list, but the global I system lock was not heIdi by the caller. I ExaKine the registers in BALBSAVE to find the caller D!KSCHDL~ See why the caller did not hold the global system lock. ------------------------------ '-- Figure 7. CP Abend Codes (Part 19 of 23) System Codes 33 r----------------------- 1 Abend I Code Reason for Abend Action SCN001 The VDEVLINK chain is invalid. A VDEVBLOK has a link field that points to another VDEVBLOK associated with the same real device. The first VDEVBLOK is not pointed to by any other link field in the chain. IPl te restart. If the Froblem persists, examine the VDEVBLOKs in the l~nk chain as well as the one whose link field points into the chain but is not in the chain. Determine what the owner of the VDEVBICK was doing at the time. SCN002 RDEVDISA equals zero but DMKSCNEP can find no online path to the device. Check trace table for activity to the device. Try to determine why RDEVPAIHS has no online paths yet RtEVDISA indicates that the dEVicE is online. SEG001 The page wait count in VMBLOC (VMWCNI) is reduced to a negative value. InsfEct modules that update VMiCNI. Determine which module decreased VMWCNT without a corresFonding increment. -------------------- I I I I I I STR001 DMKSTK was attempting tol Verify that the counters in the stack an IOBLOK, a IRQ- I VMBLOK reflects the correct numberl BLOK, or a CPEXEICK for I of EICKs stacked for this virtual I a particular virtual I machine. If they de not, determinel machine and the ceunter I who has overlaid either VMSTKCNT I in the VMBLOK overflowed I (the count of IOBLOKs, TRQELOKs, I its half-word boundary I and nermal CPEXBLOKs) or VMPRRCT I making the counter I (th e count of processor related I appear negative. Since I CPEXBLOKs). If the veBLOK countersl this will happen only I -are accurate, identify the caller I when the counter exceedsl of DMKSTK by looking inSWTHSAVE I 32,767, the probable I in the PSA of the abending proces-I cause of this error is I sore Ihe R14 value in the savearea either a program leoF I contains the return address of the that includes the I caller of DMKSIK. stacking of a CPEXBICR, I IOBLOK or TRQEIOK, or I an overlay of the I VMBLOK. I STP.OO 1 LEA gets a translatien I If the problEm persists, obtain a or length condition cedel dump and call IBM fer software for a valid page~ I support. STR003 I An attempt is being madel to migrate a table into I storage for a segment I I that is already valid. I ----------------1 STR004 1 An attempt is being"madel 1 to bring a page intc 1 storage that does net 1 exist. STR007 Figure 7. 34 I The save area stack chain is invalid or the specific request could not be found on the chain. I I I 1 I 1 I I I CP Abend Codes (Part 20 of 23) IBM VM/SP System Messages and Codes r- , Abend I Code , I Reason for Abend Action I I ----.--1 Try to identify the extreme load I condition that caused the prob- I lem. If the storage requests are , valid and the problem occurs , regularly, alter the DMKCPI modulel to allocate more than six pages I of free storage per 256K bytes I ef storage. I ,,, SVC001 No free available areas. , SVC002 A supervisor state SVC was issued without the global system lock. Use the supervisor cld PSW in the PSA of the abending processor to identify the module that issued the SVC without the system lock. An unrecoverable tASt I/O error occurred on a paging device. In most cases, location X'E9' will contain the unit address of the failing device. For certain errors it may be necessary to scan the trace table (from the current entry) looking for an I/C interrupt from a paging device with a CSW error. Call IBM for hardware support. SVC004 Error in SVC 24 CPEXELOK, maintenance. An SVC 24 I has been issued during , the EXTEND process. , There is no preallocated I CPEXBLOK available for I use by SVC 24. Most , likely the system is , attempting to enter I EXTEND while already I performing EXTEND I processing. I Examine the internal trace table to determine why the two preallocated SWITCH CPEXBICKs have not been dequeued. TDK001 A program is attempting to deallocate a cylinder or FB-512 extent(s) of T-disk space fer which no cylinder allocation bleck (ALOCBLOK) exists. For FB-512 devices, the I allocation control bleck, is called ALOFELOK. , TDK002 A program is attempting to deallocate cylinder(s) of T-disk space that are not marked alloca ted. Verify that B8 points to a RDEVBIOK for a CP-owned volume. If it does not, the error may originate in the calling program. Identify the caller by the return address and base register in the SAVEAREA peinted to by R13, and try to idenify the source of the incorrect BDEVELOK address. If the RDEVBLCK is valid, it may be that the cylinder number passed is incorrect. The VDEVBLCK for the device for which the T-disk was defined may have been destreyed. If the cylinder number appears valid, examine the allocation record on the real volume by running DMKFMT (Format program), invoking the ALLOCATE option witheut allocating any new space. If the output shows that deallecated cylinder falls within an area defined for T-disk allocatien, the ALOCBLCK or ALOFBLOK chained to the BDEVELOK may be destroyed. ,, ,,, , ,,, , , SVC003 I ,, ,,, ,, storage is for save ------ , I I I I -------------1 I.-- Figure 7. CP Abend Codes (Part 21 of 23) System Codes 35 Abend Code ------------------ Reason for Abend UDR001 The user directory module is looping trying to read all of the UDIRBLOK page buffErs from the directory device, or a directoIY containing over 10,S1E users was loaded. UDR002 The resident page count in the VMBLOK (VMPAGES) I is reduced to a negative, value. , VCX001 DMKVCX issues this abend, Check the IUCV Faths and SNA CCW if the Inter-User Com- , control blocks to determine what munication Vehicle , is in error. (IUCV) paths for SNA , Console Communications , Services (SN A CCS) are, invalid. , VCX002 DMKVCX issues this abend, if SNA Console Communications Services (SNA CCS) control block structure is invalid. Examine the control block structure and SNA CCS trace table entry for the abend to determine what is in error. VDR003 The DASD link chain is invalid. In the case cf minidisks, attaching a minidisk that pcints to an RDEVBLOK whose count of users is already zero causes this abend. IPI tc restart. If the problem persists, examine the RDEVSYS flag. If the RDEVSYS flag is off, the problem is especially serious; Frint and examine the dumF. Examine the VDEVBLOK and RDEVBLCK checking the link chain. VDSOO 1 A virtual device definition has been reguested for a minidisk that is already defined to the system (either as a different device to the user or a device to another user on the system). The directory indicates that the minidisk uses the virtual reserve rElease logic, but there is nc existing VRRBICK. Examine the virtual blocks for the existing links to the minidisk and determine why the existing virtual device block pointed to by R3 does not point to a VRRBLeR. igure 7. 36 I I Action I I Use the DASI Iump Restore Frogram I to print the UDIRBICK page buf- , fers from the directory device. , Determine whether the chain pointers are valid. InsFEct modules that update VMPAGES for the virtual machine. Check the routine to determine why it is inconsistent with the I number of CCRTABLE entries I assigned to/this virtual machine. CP Abend Codes (Part 22 of 23) IBM JM/SP System Messages and Codes ,--I Abend I Code Reason for Abend Action VI0002 DMKSCNVU was unable to locate all of the virtual I/O control blocks for the virtual unit address associated ~ith the interrupt just stacked. Verify that the unit address in the field IOBVADD in the IOBIOK pointed to by R10 is valid for the user who initiated the I/O. The field IOBUSER contains the address of the user's VMBLOK. If t-he address is valid, the integrity of the user's virtual I/O configuration has Frobably been heen destroyed. If the address is net valid, the IOELeK has been altered, or was built incorrectly in the first place. VI0003 DMKIOS has returned an IOBLOK indicating a condition code of 2 was received from the SlARl I/O for the operation. Condition code 2 shculd never be returned to the virtual I/O interrupt handler. Its presence indicates either a failure in the I/O supervisor (DMKIOS), or that the status field in the IOBLOK (IOESTAT) has been destroyed. VMA008 The resident page count in the VMBLOK (VMPAGES) I is reduced to a negative I value. I I I InsFect modules that update VMPAGES for the virtual machine. Check the reutine to determine why it is inconsistent with the number of CCRTABLE entries assigned to this virtual machine. VMDOO 1 The dump chain anchored DMKRSPDP has lost the inprocess VMDUMP. Initialize the system to restart. If the problem persists, notify the system Fregrammer. VSP001 The virtual spooling manager could net locate all virtual centrol blocks for an interrupting unit. Verify that the unit address (IOEVADD) in the IOELeK is valid. If the address is valid, the integrity of the virtual I/O configuration has Frobably been destrcyed. If the address is not valid, the IeBLOK has been altered or was built incorrectly. VSR001 DMKVSRLD was called to analyze a 3800 OF-cede and the CCW op-code in VSPCCW was not a valid 3800 Load CCW. Determine the caller of DMKVSRLD and see why it was called when VSPCCW could not be handled by this module. Figure 7. -------------------------------~ CP Abend Codes (Part 23 of 23) System Codes 37 eMS Abend Codes problem does arise, a copy of your terminal activity is a problem does arise, a copy of your terminal activity is available for reference. If th~ session is uneventful, the resulting printer file can be purged. USER ACTION When a CMS abend occurs, JOu can either: 1. Enter DEBUG mode subcommand, or the DUMP 2. Get a CP read on your terminal, er fcp, and issue the DUMP ccmmand. tY1?e and issue Either of these actions causes a dump of s~orage to be performed. Do not issue the DUMP command in CMS mode, because abend precessing will take place before the dump is perfcrmed and the indications of the error will tE lost. lest. 3. 38 Save the console sheet. If you are using a display terminal as your virtual console, it is a good idea to spccl your console output to the printer by issuing the CP command SPOOL CONSOLE S~AET either at the start of the sessicn or ty having the command in your PROFILE EXEC. ThEn if a IBM VM/SP System MessagEs and Codes 4. After the DUMP command is executed, the system automatically initiates recovery procedures, so it should not be necessary to 1PL CMS again. If, however, an error message is displayed indicating that error recovery has failed, you should reini tiali 2e (via IPL) CMS. 5. To report a CMS problem, give the dump, the censole sheet (or printed console file, if it was spooled), and copies of the CMS files involved to system support personnel. Figure 8 lists the CMS abend codes and the modules that issue them, the cause of the abnormal termination, and the action the user should take to recover and continue. ~------------------- Code I Module Name 001 DMSSCT The problem prcgram encountered an input/cutput error processing an os macro. Either the associated DCB did not have a SYNAD routine specified or the I/O error was encountered processing an OS CICSE macro. Message DMSSCT120S indicates the possible cause of the error. Examine the error message and take the action indicated. 034 DMSVIP The problem program encountered an I/O error while processing a VSAM action macro under VSE/AF for which there is DO OS eguivalent. An iDternal error occurred iD a VSE/VSA! rcutine. Refer to the lSE/VSA! Message§ ~ Codes to determine the cause of the VSAM error. OCx DMSITP The specified bardware exception occurred at a specified location. "x" is the type of exception: Type DEBUG to examine the PSi and registers at the time of the exception. A~endl Cause of Atend .I o 1 2 3 " 5 6 7 8 9 A B C D E F Action !l:,E~ IMPRECISE OPERA'IION PRIVIlEG!t OPERATICN EXECUTE PROTECTION ADDRESSING SPECIFICATION DECIlUl tATA FIXED-POINT OVERFleW FIXED-POINT DIVltE DECIMAL OVERFLOW DECIMAL tIVIDE EXPONENT OVERFLOW EXPONENT UNDERFLOW SIGNIFICANC! FLOATING-FCINT tIVIDE OFO DMSITS Insufficient free storage is available to allocate a save area for an SVC call. If the abend was caused by an error in the application program, correct it; if not, use the CP DEFINE C9mmand to increase the size of virtual storage and then restart CMS. OF1 DMSITS An invalid halfword code is associated with SVC 203. Enter DEEUG and type GO. Execution continues. Figure 8. CMS Abend Codes (Part 1 of 4) System Codes 39 Abendl Module Code I Name Action OF2 DMSITS The CMS nesting level of 20 has been exceeded. None. Abend recovery takes place when the next command is entered. OF3 DMSITS CMS SVC (202 or 203) instruction was executed and prov1s1on was made for an error return from the routine processing the SVC. Enter DEBUG and type GO. Control returns to the point to which a normal return would ha ve been made. OF4 DMSITS The DMSKEY flowed. Enter DEBUG and type GO. Execution continues and the DMSKEY macro is ignored. OF5 DMSITS The DMSKEY key stack underflowed. OF6 DMSITS The DMSKEY key stack was not empty when control returned from a command or function. Enter DEBUG and type GO. Control returns from the command or function as if the key stack had been empty. OF? DMSFRE Occurs when TYPCALLLSVC (the default) is specified in the DMSFREE or DMSFRET macro. When a system abend occurs, use DEBUG to attempt recovery. OFB DMSFRE Occurs when TYPCALL=BALR is specified in the DMSFREE or DMSFRET Macro devices. When a system abend occurs, use DEBUG to attempt recovery. 101 DMSSVN The wait count specified in an os WAIT macro was larger than the number of ECBs specified. Examine the program for excessive wait count specification. 104 DMSVIB The os interface to VSE/VSAM is unable to continue execution of the problem program. See the additional error message accompanying the abend message, correct the error, and reexecute the program. Figure B. 40 Cause of Abend CMS Abend Codes key stack over- (Part 2 of 4) IBM VM/SP System Messages and Codes Abend I Module Code I Name Cause of Abend Action 155 DMSSLN Error during LOADMOD after an OS LINK, LOAD, XCTL, or ATTACH. The compiler switch is on. See the last LOADMOD (DMSMOD) error message for error descr~ption. In the case of an I/O error, recreate the module. If the module is missing, create it. 15A DlIISSLN Severe error during load (phase not found) after an OS LINK, LOAD, XC~L, or ATTACH. The compiler switch is on. See last LOAD error message (DMSLIO) for the error description. In the case of an I/O error, recreate the text deck or TXTLIB. If either is missing, create it. 174 DMSVIB OS The interface VSE/VSAM is unable to tinue execution of problem program. See the additional error message accompanying the abend message, correct the error, and reexecute the program. 177 DMSVIB DMSVIP The OS interface to VSE/VSAM is unable to continue execution of the problem program. 200 DMSSFF There is an error in overlay process. 240 DMSSVT No work area was provided in the parameter list for an OS RDJFCB macro. Check RDJFCB cation. 400 DMSSVT An invalid or unsupported form of the as XDAP macro was issued by the problem program. Examine program for unsupported XDAP macro or for SVC O. 500 DMSTLB A block count error was detected when read~ng a SL tape. User replied 'cancel' to message 425R or the user's program contained a block count error routine that returned a code of 0 under as s~mulation. 704 Figure 8. DMSSMN to conthe Find out what caused the error and rerun the job. the An OS GETMAIN macro (SVC 4) was issued specifying the LC or LU operand. These operands are not supported by CMS. specifi- Find out what caused I the block count error. I Then reload CMS and reI run the job. I I I I Change the program so that it specifies allocation of only one area at a time. CMS Abend Codes (part 3 of 4) System Codes 41 Ir----------.~----------Abend, Module Caus~ of Atend I Code I Nallle Action I--~-------------' ------~------~--~----------------Change the program se '70~ DMSSMN An OS FEIE!AIN macro that it specifies the 5SVC 5) was issued specifyrelease of only one 1ng the L operand. This operand is not supported by area at a time. CMS. I I DMSSMN ,804 80A Check the program for a valid GETMAIN reguest. If more storage was requested than was available, increase the size of the virtual machine and retry. I If you ran out of stor-I age while trying to I acquire a large GE~MAINI area, and your Virtual I machine size is above I the start of the CMS I nucleus, you should I IPt a CMS system gener-I ated at a higher virt- I ual address that the I ene you are using. If I the saVE system CMSL is available, IPL it, if not, contact your system support personnel. An OS GlTMAIN macro (804SVC 4, 80A - SVC 10) was issued that reguested either zero bytes of storage, or more storagE than was available. I I I I I I I I I I , ------------------~--------------------------An aS FRIEMAIN macro .(S05 - I check the program 905 DMSSMN 90A SVC 5, 90A - SVC 10) was I a valid lREEMAIN for reissued specifying an area guest; the address may to be released WhOSE ad- I have been incorrectly dress was not on a doutle- 1 specified or modified. word boundary. -----I An OS 1REEMAIN Dacro (A05 - I SVC 5, AOA - SVC 10) was, issued spEcifying an area 1 to be rEleased which over- 1 laps an Existing frEe arEa. 1 , , A05 AOA DMSSMN !--------~-------------8. CMS Abend Codes (Part 4 of 4) ~i9ure 42 IBM VM/SP System MessagEs and COdES I DMK Control Program (CP) Messages 001E ?CP: command ExElsnstion: The command specified is not a valid CP command, or a validCP command was entered prior to logging cn to VM/SP. • If the NOT HEADY command is issued for a device other than a spooled unit record or console device. • If the device specified with a READY command is a virtual channel-to-channel adapter that has not yet been attached via the COUPLE command to another device. The virtual CTCA can be made ready only by issuing the COUPLE command. • The user has issued a SET VMSAVE command for a DASD type with the volid specified in the NAMESYS macro. Module DMKSNT is not supported for this function. • The operator attempted to set TERMINAL CONMODE 3270, BREAKIN, SCRNSAVE, or BRKKEY on a console that is not a local non-SNA display unit with a 3270 compatible command set. • The operator attempted to set TERMINAl CONMODE, EREAKIN, SCRNSAVE, or BRKKEY without a virtual console defined. User Action: Reissue the command in full, or-In~he-Proper abbreviated form. 002E INVALID OPERAND - operand ~zE!~tiQB: One of the operands was incorrectly specified. !his message ~s also displayed if a MONITOR STOP command is issued while data collection is inactive, or if a MONITOR STAR! command is issued and data collection is already in progress. User Action: Reissue Va Ii d d. operan the command with a 003E INVALID OPTION - option ~ZElanati2n: One of the options was incorrectly specified or is invalid with the particular variation of the command. The option may be shorter than the minimum abbreviation required. User Action: Reissue Valid 'Option. the command with a User Action: Reissue the command; with a valld--ae;Ice type. For some of the requests, there can be no user action because a real device does not allow the option specified. 007E INVALID USERID - userid 004E INVALID HEXLOC - operand ~Zflangtign: ~he hexadecimal lccation is incorrect because of nonhexadecimal data in the operand or the operand is longer than six characters. If the operand was not a hexadecimal location, it was misspelled. User Action: Reissue th~ the-operand correctly. comman!; specify Ixplans!iQB: The userid eight characters. User Action: Reissue valid userld. contains more than the The spoolid a valid decimal number, than four digits. lz£!~n: The hexadecimal data supplied either contains nonhexadecimal characters or is longer than eight characters. User Action: Reissue the the-hexadecimal data. command; specify a DOSE INVALID SPOOLID - spoolid ~lanatio~: 005E INVALID HEXDATA - hexdata command with User !£!ign: Reissue valId spoolid number. the specified was not or it was larger command with a D09E INVALID RANGE - range ]~~io~: 006E INVALID DEVICE TYPE - addr EXFl~tion: The device type specified is not recognized as a valid CP device, or it is incorrect for the function reguested. Examples of conditions that caUSE this message to be displayed are: • If a teletypewriter terminal user issues a TERMINAL APL ON command. The range of addresses or registers specified is incorrect. For instance, the end address may be smaller than the starting address, too many ranges were specified, or the number of pages to be lo.cked may be equal to or greater than the number of pages available in the dynamic paging portion of real storage. Y§§I !£tio~: Reissue the command; specify the range. Control Program (CP) Messages 43 DMK 010E INVALID REGISTER - register 01QE TAPE raddr DUMP TAPE CAPACITY EXCEEDED Ex£!snation: The register s~ecified is not in the range 0 through 15 or hexadecimal 0 through F, or the register specified is not 0, 2, 4, or 6 for a floating-point register. !!]l~~ion: Cn the SPTAPE command with the DUMP option, the tape defined by raddr has reached end-of-reel before all spool files were dumped. Action: The tape is file marked at the last complete spool file, the tape is unloaded and the command is terminated. ~I21~ User Action: Reissue the command; specify a validregister. !£tiQB: Use a larger tape reel or dump by spool class or type. Q§~!: 011E INVALID DEVICE TYPE - userid vaddr ]~R1gnati~: The device type is invalid. If this is a DIAL command, the device specified is not a virtual low speed line. If this is the COUPLE command, the device that was specified is net a virtual channel-to-channel adapter. User Action: Ensure that the device is the corre~type for the function, and reissue the command. 012E INVALID PSW - psw 017E INSUFFICIENT AND REDIAL SCREEN SPACE - CLEAR SCREEN £~Elgnation: A DIAL command was issued from a local 3270 terminal with an insufficient number of lines left on the screen to display the command and resulting message. If allowed to proceed, the terminal would go into a holding state. This would tie up the terminal, because the processing of DIAL disables the terminal from unsolicited interrupts, thereby preventing the release of the holding state. ~~]lg~iQll: The PSW (program status word) specified by the STORE command is invalid. An invalid PSW is one where: • • The virtual machine is operating in extended control mode and some of the bits that are defined by the architecture to be zero have been turned on, or The virtual machine is operating in basic control mede, and the extended control mode bit has beEn specified. Us~ !£!i2B: Change the PSW to a valid format for the mode of the virtual machine. If this is not done, attempting to run the virtual machine with an invalid PSW causes an invalid PSW message to be issued from the CP dispatcher. screen and then 020E USERID MISSING OR INVALID The userid is either missing or invalid. It may be longer than eight characters. This message is also issued if a user who does not have privilege class D issues the command QUERY FILES CLASS x userid, because the userid operand is valid only for class D users. j~lg~ioB: User Action: Reissue valId userid. the command with a 021E RADDR MISSING OR INVALID ExE1gnation: The real device address is either missing or invalid. An invalid device address is more than three characters long or contains nonhexadecimal characters. 013E CONFLICTING OPTION - option ~~£!sBg~ion: User Action: Clear the reIssue-the command. This message occurs when: • The same option is. specified twice the same command, or in • The fUnction required by the given option is incompatible with a previously specified operand. User Action: Reissue the valId real device address. command with a 022E VADDR MISSING OR INVALID £~Elg~~i2B: • DSS was specified in a VMDUMP command but no discontiguous segments exist. The virtual device address is either missing or invalid. An invalid virtual device address either: • The function requested is with the system. • Is longer than three characters, or • Contains nonhexadecimal data, or • Is greater than X'SFF' for a virtual machine running in basic control mode, or • Is associated with an unsupported device incompatible Us~~ !£!i~: Consult the lnLSP CP Command ~~n!!.£.!l !.Q!: ~~~!:sl USll§ for the correct specification of the command and the allowed options, and reissue the command. qq IBM VM/SP System Messages and Codes D!I< type (specified vaddr) • in the command IPL 028E CLASS MISSING OR INVALID j!]lanatio~: Us~ Action: Reissue the command with valid virtual device address. a 023E VOLID KISSING OR INVALID The class value is either missing or invalid. An invalid class is one that is not in the range A through Z or 0 through 9. User Action: Reissue valId class: Ex]lA~~tio~: The volume identification is either missing or invalid. A volid longer than six characters is considered invalid. ~~I jction: Reissue the command with valid volume identification. 024E {CYLSIBLKSIFORK NUMBER} MISSING a OR INVALlt the command with a 029E FNAKE FTYPE MISSING OR INVALID ~~]l~n~!!ga: The filename and/or filetype is missing or invalid. An invalid filename is larger than 24 characters. An invalid filetype is larger than eight characters if the filename is eight characters or less. ~!Ela~tign: The number of cylinders (or blocks if FB-512) must be specified with the command, but it is missing or invalid. An invalid cylinder specification is one that is four or more characters, or larger than the maximum number of cylinders available on the device type specified. An invalid block number specification is one that is seven or more characters, or larger than the maximum number of blocks on the device type specified. If 'FORK NUMBER' appears in the message text, the form number following the FeRM keyword is missing or it is over 8 characters long. User Action: Reissue the command; specify the-reqUired filename and/or filetype. 030E COPIES MISSING OR INVALID EXEI~Dation: The operand that specifies the number of copies is either missing or invalid. An invalid copy specification is nondecimal or greater than 99. User Action: Reissue the command; specify the-requIred number of copies. Us~ Ac1i2n: Reissue the ccmmand; specify the number of cylinders, clocks, or form number correctly. 031E EUFFER MISSING OR INVALID Explanatio~: The required buffer name is either missing or invalid. An invalid buffer name i~ longer than eight characters. 025F STORAGE MISSING OR INVALID ~!£!~~!!gn: The amount of storage is either missing or invalid. An invalid storage specification contains invalid digits or does not end with the letter K or M. User Action: Reissue valId buffer name. the command with a 032E DISTCODE MISSING OR INVALID User !£1ign: Reissue the the- storage requirement. command; specify distribution code is lZElanation: The either missing or invalid. An invalid distribution code is longer than eight characters. 026E OPERAND MISSING OR INVALlt ~!]lanation: A required operand missing or invalid. Q§~ !ctio~: Reissue the is either command with command with a a valid operand. ~27E User Action: Reissue the valid distribution code. 033E HEXLOC MISSING OR INVALID ~~]l~!ioa: SPOOLID KISSING OR INVAIlt lI]lanatign: The command requires that a spoolid be supplied, but it is either missing or invalid. An invalid spoolid is one that contains nondecimal characters. Q~~ !£!i2n: Reissue valid spoolid. the command with The hexadecimal location is either missing or invalid. An invalid hexadecimal location is one that contains nonhexadecimal characters or is longer than six characters. User Action: Reissue the command with valid hexadecimal location. a a Control Program (CP) Kessages 45 DMK 034E CHANNEL MISSING OR INVALID E~R!~nA1iQB: The channel number is either missing or invalid. An invalid channel number either is longer than one character or is nonhexadecimal. User Action: Reissue valid channel number. the command with cemmand in UP or AP modes, if specified it will be checked for validity. In AP mode, the processor address must be that of the I/O processor. ~!~~ Action: The ATTACH/DETACH command Is-rejected. CHANNEL a QPerat2! Action: Reissue the ATTACH/DETACH CHANNEL command with a valid processor address. 035E DEVICE TYPE MISSING CR INVALID 040E DEV addr DOES NOT EXIST lz~lanatiQB: The command requires that a valid CP spool device type be entered as an operand, but it is either missing or invalid. Valid device ty~es are READER (R, RDR), PRINTER (P, PRT), and PUNCH (PU, PCH). User Action: Reissue the valId spool-device type. command with a 036E INDEX MISSING OR INVALID ~~£1g~!ioB: If INDEX MISSING is the condition, the requested FCE (forms control buffer) image in DMKFCB does not have an index value, therefore one must te su~plied in the command. If INDEX INVALID is the condition, nn was not a number frem 1 to 31, where nn corresFonds to the numter of the first print position. ]AElanation: The device address specified does not exist, or a TIO to that device resulted in condition code 3. If the device address is a real device, it is not configured in the CP system, or the device is configured in CP but is not operational; if it is a virtual device address the virtual device is not configured in the virtual machine. If the specified device address is valid, this message may indicate a problem with the Network Control program and/or the 370x. User Action: Reissue the the- -required real or address. command; specify virtual device 041E LOGMSG nn DOES NOT EXIST Q§~! !£1ign: Supply the value fat INDEX in the FCB image or ensure that nn is a number from 1 to 31, whichever is appropriate. Reissue the command. 037E TAPE raddr INVALID FCR SPTAPE CCMMAND ~ZB!~B~!ioB: The SET LOGMSG command has been issued reguesting a specific log message line, and the log message line does not exist. User Action: Reissue the command; specify the-reguIred log message line. ~~£1~ti2B: On the SPlAPE command with the LOAD/SCAN options, the taFe specified by raddr was not generated by SPTAPE commands I 042E SPOOLID nnnn DOES NOT EXISTIiiake sure that the file exists, issue STATE fn ft * or LISTFILE fn ft *. correct and reissue the command. For DMSSPR, access the disk having the required module or respecify a different module in the calling sequence and then reissue the SETPRT command. For a DMSROS TEXT file, ensure that the file is accessible and reissue the command. 0021 FILE 'fn' TXTLIB NOT FOUND Explanation: The specified TXTLIB file was not found on the accessed disk~s). Either the file does not reside on this disk, the file identification was misspelled, or insufficient identification was provided to cause the proper disk to be searched. This message will also occur in the following situations: a user issues a GLOBAL command for a TXTLIB and then erases or renames the TXTLIB, or releases the disk on which it resides then enters the command SET SYSNAME, or if the CMS segment is not available when the user accesses an OS disk or DMSSVT. = system !ill.2B: RC 0 Execution of the command continues. User ~: If 'fn TXTLIB' is required for command execution, make sure that it exists and is on a disk that is accessed. otherwise, ignore the message. 002W FILE 'fn ft [fm)' NOT FOUND For the ZAP command, either none of the libraries specified for a TXTLIB or L01DLIB cou.ld be found, or the INPUT filename could not be located via the STATE macro. For the PRELOAD command, either the loadlist EXEC, the eNTRL file, or one of the input text files could not be found. see the nL.aR CMS Command and Macro Reference for a description of-the file identification required by each command and the search procedure used. For the ASM3105 ~~ion: The specified file was not found on the accessed disk(s). Either the file does not reside on this disk, the file identification was misspelled, or incomplete identification was provided to cause the appropriate disk to be searched~ (see the llL.2.f ~ Command and Macro Reference for a description of the file identification required by each command and the search procedure used.) System Action: DMSGLB issue RC 28; all Conversational Monitor System [CMS) Messages 111 DMS 4. other modules issue RC the command continues. Execution of The system status remains the same. User Action: To make For DMSGLB, the old MACLIB or TI~LIB list is cleared and the new list contains all specified libraries except those that are not found. For DKSGND, there will be no entry directoty for the file not found. in the sure the file exists, MAP against all DOS LIB files. If the file resides on a DOS-formatted disk, a DSERV will help locate it. Issue~command DOS LIB 004W WARNING MESSAGES ISSUED processor !~lanation: For DMSLBM, the file not found will not be in the MACLIB. processing continues with the next filename if one exists. The language returned completion code 4. .2.I§!:gjl Action: RC = 4 The system status remains the same. For DMSLBT, processing continues next filename if one exists. with the ~ Actio~: Look for additional messages that may have been issued by the compiler. For DMSZAP, if a library name was specified, the next library name (if one is present) is used. If a MODULE file was specified, all control records encountered until the next NAME, DUMP, or END control record are ignored. OOSE NO 'option' SPECIFIED Explanation: The indicated option entered in an incomplete form. was Action: RC = 24 Execution of the command is terminated. The system status remains the same. ~lligjl User Action: To make sure the file exists, iSSUe STATE fn ft * or LISTFILE fn ft *. Make sure that the disk on which the file resides is accessed. For DMSGND, if you must have the file not found in the directory, take steps to supply the file. Correct and reenter the command. For DMSLBM, if the MACLIB exists after execution of the command, use the MACLIB ADD command to add the file to the library. For DMSLBT, supply the necessary file using the TITLIB ADD command. 003E INVALID OPTION 'option' Explanation: The specified option is invalid. It may have been misspelled or, if the option is truncatable, it may have been truncated improperly, or it may conflict with another option in the command line. System ActiQ.!!: RC = 24 Execution of the command is terminated. The system status remains the same. For DMSLIO, some option processing may have caused user storage to be cleared or the location counter set, etc. This should not interfere with a subsequent LOAD command. User Action: Coiiiian-d-.- - Correct and reenter the 004E {BOOK 'subl.book'IMODULE 'module',PHASE 'phase'IPROCEDURE 'procedure'} NOT FOUND Explanation: The specified book, module, phase, or procedure was not found on the accessed disk(s) as a result of a FETCH ,SVC 1 or SVC 2). System A£ti2!!: RC = 28 Execution of the command 112 User Action: specifying the option. Reenter required 006E NO READ/WRITE ['A'] DISK ft'] the data ACCESSED [FOR 'fn Explanation: The user does not have access to a read/write disk on which the command can write its output or utility files. If the message displayed is NO READ/WRITE 'A' DISK ACCESSED, the command, in order to be executed, requires that the A-disk be accessed in read/write mode. For RECEIVE, SENDFILE, or DISCARD (which is equivalent to RECEIVE issued with the PURGE option) the LOG option was in effect, and no read/write disk was accessed. Action: RC = 36 Execution of the command is terminated. The system status remains the same. ~Y§tem User Action: Access a read/write disk and command, or issue the CP LINK command to reset the A-disk to read/write mode, access the A-disk again, and reissue the command. reissue~e 007E FILE 'fn ft fm' RECORDS [IS] NOT FIXED, terminated. IBM VN/SP System Messages and Codes 80 CHAR. Explanation: The specified file must have fixed-length, 80-character records in order for the command to be executed. System Action: RC = 32 Execution of the command is terminated. The system status remains the same. For the UPDATE command, the have occurred: is command, for the following may DMS • • • If a file with the fileid "$fname ftype" existed on the out~ut disk before the command was entered, this file may have been erased. If the DISK option was in effect and a file with the fileid "fname UFDLOG" existed on the output disk before the command was entered, this file may have been erased. If the CTL option was in effect and a file with the fileid "fname UPDATES" existed on the output disk before the command was entered, this file maj have been erased. The system status remains the same. User Action: Reissue the specifying the correct column. command, 010E PREMATURE EOF ON FILE 'fn ft [fm)' !xplaBatioB: For DMSCMP, an end of file occurred on one of the files being compared before the end of file was received on the other. For DMSTPE, a tape mark was encountered on the file before the file was completely loaded. ~.Y§1~m • If UPDATE processing began before the error was detected, any or all cf the following files may have been created on the output disk: UPDATE CMSUT1 $fname ftype fname UPDLOG fname UPDATES - if in - if in the DISK option was effect the CTL option was effect User Action: It is possible that an Incorrect--fileid was specified in the command line. In this case, reissue the command. If, however, the fileid was correct but the file is in the wrong format or does not contain aO-character records, change the file's format and/cr record length with the COPYFILE or EDII command. 008 E tEVICE 'cuu' {INVALID NONEXISTENTIUNSUPPORTED DEVICE TYPE} Ac!iQ!!: RC = 36 Execution of the command is terminated. The system status remains the same. User Action: Use the CP DEFINE command to proviae--a- suitable virtual device and reissue the command. 008W ERROR MESSAGES ISSUED Ex,£lan..§!ign: The language returned completion code a. processor .§ll!g Acti..Q'!!: RC = 8 The system status remains the same. User Action: Look for additional messages that may-have been issued by the compiler. 009E COLUMN 'col' EXCEEDS EECOED lENGTH E~li"§Mtion: outside the file. The column specified lies logical record length of the Acti..Q1!: RC = 24 Execution of the command For DMSTPE, a temporary file called "TAPE the data has been CHSUT1" containing created on the A-disk or on the disk specified by the user. "TAPE CMSUT1" contains fixed-length, aOO-byte records. y~~~ A~!i..Q'!!: For DMSCMP, this normally indicates that the files being ccmpared had an unequal number of records. If the command was Froperly specified, no action is necessary. For DMSTPE, the file may to tape again. have to be dumped 010W PREMATURE EOF ON FILE Ifn ft NUMEER ' ___ ._._.' NOT FOUND fm' -- SEQ OR Ex~l~tign: The virtual machine does not have a virtual 1403 or 3211 printer, Funch, or reader. ~!.m!! Actio,!!: RC = 40 Execution of the command is terminated. The system status remains the same. ~ZE1..§natio.!!: The update file contained an error. A control card specified a search for a sequence number which exceeded the value of any sequence number in the file being updated. As a result, a premature end of file occurred on the input file being updated, before the sequence number specified in the control card could be found. Action: RC = 12 UFdate -proceSSing continues, and, if the CTL option was specified, additional update passes are made. §l§!~m If several warning messages are generated during the updating process, the final return code when the UPDATE command has finished processing is the maximum of all return codes (4 or 8 or 12) associated with the generated warning messages. The BEP option, if it was specified, is ignored, and the final update deck has the fileid '$fname ftype l • See the explanation of message DMSUPD177I for further informaticn en the meanings of the UPDATE warning return codes. y~~ Action: Correct the invalid control card in- the update file, and reenter the UPDATE command. ~'yst!lH!l is terminated. Conversational Monitor System (CMS) Messages 113 DMS 011E CONFLICTING FILE FORMATS Ex~lanati~: The filetypes specified do not have the same record format; that is, one is fixed-length and one is variable-length, or the record lengths differ. .§.Yst.§l!! !£tiQ!!: RC = 32 Execution of the command is terminated. The system status remains the same. User Action: Change the theCOPYFILE command. l~~!~!!~tion: processor The language returned completion code 12. Ac!iQ!!: RC = 12 The system status remains the same. ~y§!~~ User Action: Look for additional messages that may-have been issued ty the compiler. IN LIBRARY ['fn ft ~£1~~atiQ!!: The specified member found in the library. was not RC = 32 Execution of the command is terminated. The system remains in the same status as before the command was entered. ~§!~.!!! Acii~: Us~.£ Action: Use the MACIIB MAP, 'lXTLIE MAP, or-IOADLIB LIST command to display the names of library members. 013W {MEMBERIPHASE} 'fn ft fm' = User Action: Reenter the specifying-a-valid function • command, 015E {UNKNOWN {CP/CMSICMSICP} {CMSISUBSET}} COMMlND IINVlI1D record format with 012W SEVERE ERROR MESSAGES ISSUED 013E MEMBER 'name' NOT FOUND fm'l 'libname' ] For DMSTPE, if the DEN, T~TCH, 7TRlCK, or 9TRACK options were specified, the modeset byte has been set for the specified device (TAPi, where: i 1, 2, 3, 4,) at TAP1. 'name' NOT . FOUND IN LIBRARY ~1~BStion: UNKNOWN CP COMMAND indicates that IMPCP (implied CP) was on so the command was passed to CP, tut no CP command could be foUnd with the name entered. UNKNOWN CMS COMMAND indicates that no CMS command, CMS or user EXEC file, or user MODULE file exists by the name entered. UNKNOWN CP/CI1S COMMAND indicates that no CP or CMS command could be found with the name entered. INVALID CMS COMMAND indicates that an error has LOADMOD. occurred in INVALID SUBSET COMMAND indicates that the loader has tried to load a routine at an address equal to or higher than X'20000'. The command you issued may be a valid CMS command, but not a valid subset command. ~l§i~.!!! A£!iQ!!: A positive return code is passed if an error occurs in CP processing. A negative return code is passed if the command entered is considered an invalid CMS command. The system status remains the same. The member or phase specified was not found in the specified library. If REPLACE was specified, the new member is added. ActiQn: RC = 4 processing continues filename. 016E NO PRIVATE CORE IMAGE LIERARY FOUND ~y§!~~ Q§~.£ with the next Actio!!: None. ~~~!g!!Stion: The private Core Image Library called does not exist on the accessed disk, or the DLBL was incorrect. Action: RC = 28 Execution is terminated. remains the same. ~yste~ 014E INVALID KEYWORD 'function' ]~~~!ion: The keyword 'function' specified ~s misspelled or invalid. For the DEFAULTS command, a function other than SET or LIST was specified. !ctiQ!!: RC = 24 Execution of the command is terminated. The system status remains the same, with the following exceptions: User Action: Access the alter t~invalid DLBL. System proper status disk or 016W 'IERMINAL ERROR MESSAGES ISSUED ~st.§l!! ]~~lg!!Stion: The language returned completion code 16. processor Acti.gn: RC = 16 The system status remains the same. ~llte.!!! For DMSOVR, SVCTRACE is was previously on. turned off if it Use.£ !£j:ion: 114 IBM VM/SP System Messages and Codes Look for additional messages DMS that may have been issued by the compiler. 021E ENTRY POINT 'name' NOT FOUND !AElanation: For DMSGND, the specified directory name was not found in the loader tables. 017E INVALID DEVICE ADDRESS 'cuu' EXFlanation: The device address was not specified correctly, or the device was not accessed. ,!cti,Q!!: RC = 24 Execution of the command is terminated. The system status remains the same. ..2.I§1~! User Action: Check the specified address and-reissue the ccmmand. device For DMSLIO and DMSNCP, an entry point name specified either with the START command or on an LDT card could not be located in the loaded TEXT files • For DMSMOD, the name used with the FROM or TO option of the GENMOD command does not occur in the currently loaded files. jction: RC = 40 Execution of the command is terminated. The system status remains the same. ~1~~ Note: For a virtual machine with EC~OtE on, a--Valid cuu is within the range X'001' through X'FFF'. Otherwise, a valid cuu is within the range X'001' through X'5FF'. 018E NO LOAD MAP AVAILABLE For DMSLIO and DMSNCP, no execution takes Loader place for LDT. Loading stops. clean-up has teen processed for the loaded files. A subsequent START command should net be affected. ~~]l~~tion: The module file was created with the NOMAP opticn of GENMOD or is a transient area routine. ,!ctign: RC = 40 Execution of the command is terminated. The system status remains the same. ~§1~! User !~io~: Regenerate the with the MAP option and comman d. Kodule file reissue the The fileids specified command line are identical. User Action: For DMSGND, reload auxiliary-~irectory and reissue command. the the For DMSLIO and DMSNCP, reissue the START command with the proper entry point or control section name, or asterisk (*). Correct the LDT card with the CMS Editor. For DMSMOD, correct the GENMOD command line or add the requested name as an external name in the files being generated. 019E IDENTICAL FILEIDS ~zEl~n~1ign: For DMSMOD, the module is not created. in the Actigg: RC = 24 Execution of the command is terminated. The system status remains the same. 021W NO TRANSIENT DIRECTORY ~1§1~! User Action: Reissue the speCifying-two different fileids. command, !~lanatioB: A request was made to display a transient directory, but neither a private core image library nor a system residence library was assigned. ,ActigB: RC = 4 Execution of the command continues until all specified directories are processed. .§l§1~ 020W INVALID PDUMP ADDRESS 'address' OPERATION PERFORMED Ne DUMP EXE1~~,Q!!: The address specified in the PDUMP macro is invalid for one of the following reasons: • • • • add2 must be greater than add1. add1 cannot be negative. add1 cannot be greater than ppend (the end of the virtual partition). add2 cannot be negative. User Action: libraries--are command. Ensure that assigned and the Froper reissue the 022E Ne DIRECTORY NAME SPECIFIED j~El~B~1igg: A directory entered with the command. name was not .§l§1~~ ..2.Ist~! !ctigg: The macro results in no operation. No dump is provided; processing continues. Q~~~ Action: None. ,ActiQg: RC = 24 Execution of the command is terminated. The system status remains the same. User Action: Reissue 'directoryname. the command with Conversational Monitor System (CMS) Messages a 115 OMS 022W NO CORE IMAGE DIRECTORY abnormally, and that it left a work file on the output disk at that time. 1Z]!g~~: A reguest was made to display a core image directory, but neither a private core image litrary nor a system residence library was availatle. !£1iQB: RC = 4 Execution of the command ccntinues until all specified directories are processed. ~st~~ Q§~ !£!igg: Ensure that the pro fer litrary is assigned and reissue the command. 023E NO FILETYPE SPECIFIED ~zE!gnatiog: The command reguires that you specify both filename and filetype. For the DLBL command, toth are reguired if you specify the CMSoperand. A£tiQg: RC = 24 Execution of the command is terminated. The system status remains the same. ~~§1~! For DMSTPE, if the D~N, ~R~CH, 7TRACK, or 9TRACK options were specified, the mcdeset byte has been set for the specified device (TAPi, where: ~ = 1, 2, 3, 4) or TAP1. User Action: Reenter the command, specifying-the filename and filetype. 023W NO RELOCATABLE DIRECTORY ~!g~!ion: A reguest was made to display a relocatable directory, but either no private or system relocatatle litrary was available or no active entries were present on the appropriate directory. For the RECEIVE command, RECEIVE was issued and a file exists. Actio,B: RC = 28 Execution of the command The system status remains the following exception: ~~~ QB~ Act~On: You can use the TYPE command to exam~ne the existing file. If you decide you want to keep it, use the EENAME command to give it a new fileid. If the file is invalid or incomplete, erase it and reissue the ccmmand; or for DMSCPY, reissue the command and specify the REPLACE option. For DMSUTL, reissue the command specifying MODIFY or REPLACE, or reissuE the ccmmand without a file ID for SYSUT2. For the RECEIVE command, use RECEIVE with the REPLACE option, or specify RECEIVE with a unigue fileid. For information on the RECEIVE command format, see the !~LSP Command and Macro Reference or issue the HE~command.----- ~Z]!~,B~!iQg: User Action: Ensure .that either the proper Ilbrary---is assigned or that active relocatable entries are available in the directory and reissue the ccmmand. ~~.§.!!! The specified file already For DMSEDI, the Editor work file, EDIT CMSUT1, already exists as the result of a previous edit session ending abnormally. For DMSXIN, the XEDIT work file, X~DTEMP CMSUT1 A1, already exists as a result of a previous edit session that ended abnormall y. For DMSUPD, a file with the fileid 'UPDATE CMSUT1' already exists. This usually indicates that the UPtAT~ ccmmand was executed previously and was terminated IBM VM/SP System Messages and Codes --------- 024W NO PROCEDURE DIRECTORY Actign: Re = 4 Execution of the command continues until all specified directories are processed. Ex]lanatiog: exists. is terminatEd. the same, with For DMSCPY, if you were creating multiplE output files, several output files may have been created before the error was discovered. ~~~! 024E FILE 'fn ft fm' ALR~ADY EXISTS [-- SPECIFY 'REPLACE' [option]] 116 For DMSUTL, the file ID for SYSUT2 specifies an existing file. This is not allowed for the COPY function because neither the MODIFY or REPLACE option was specified. A request was made to display a procedure directory but no system residence library was assigned. Act,iQl!: RC = 4 Execution of the command continues until all specified directories are processed. User Action: Ensure that the system residence-library is assigned and reissue the command. 025E INVALID DATA IN 370X CONTROL PROGRAM Explanatio,!!: One of conditions has occurred: the following For specified EP or PEP -- The implied or channel vector table was not found. For NCP or P~P -- The maximum exceeds 4086 tytes. resource ID For NCP or PEP -- The first resource is not the 370X. Actio,!!: RC = 16 Execution of the command is terminated. ~l§!~! eMS User Action: Make sure that the 370X control program has teen generated with the correct parameters and that the ccrrect CAMOD operand value was used on the SAVENCF command. For the correct parameters for 370X control program generation, refer to the VM/SP Rlg~iBg ~~g ~~~tem ~~E~!atig~ verify the device to which the logical unit is assigned. Reassign the logical unit to a valid device and reissue the command. 027W NO PRIVATE CORE IMAGE LIBRARY £~lanatio~: A request was made to display the core image directory of a private cere image library, but no entries were present. ~yide. 025W NO SOURCE STATEMENT DIRECTCE! RC = 4 Execution of the command continues until all specified directories are processed. lli.:t~ illio~: ~~£!anati~: A request was made to displaj a source statement directory, tut either a private source statement litrary or a system residence litrary was not available or there were no source state lent entries in the library available. BC = 4 Execution of the command continues until all specified directories are processed. 028E NO {DEVICEILCGICAL UNIT} SPECIFIED .§..Y.§':!:~!!! Acti~: Q.§~~ Actigg: Ensure that either the troper library is assigned or that active source statement entries are present in the directory and reissue the command. 026E INVALID PARAMETER 'function' FUNCTION 'parameter' FOR !!Blanatio~: The command requires that you specify a device address or logical unit. RC = 24 Execution of the command is terminated. The system status remains the same. ~1§!~~ !£iig~: User Action: specifyInga logical unit. Reissue the command, valid device address or ~.!..E!gnatig!!: The data sFecified for the given function is misspelled, missing or incorrect. 2.Y.§te!!! ActiQ.!!: RC = 24 Execution of the command is terminated. The system status remains the same. 02aw NO {PRIVATEISYSTEM} ENTRIES . TRANSIENT DIRECTORY l~gnatiog: No directory entries were present on the specified transient library. Action: RC = 4 Execution of the command continues until all specified directories are processed. ~y.§!~! User Action: Reissue the command, specifying-valid data for the function. 026W 'phase' NOT IN LIBRAR! ]ZBlggation: A request was made to display a certain entry or entries in a core image directory but the entry or entries were not in the library. RC = 4 Execution of the command continues until all specified directories are processed. ~tem !cti~: User Action: Reissue the specifying-the proper phase name. 027E INVALID DEVICE {'device 'SYSxxx'} command, name'l 'device' FOR ~ZBlg~tion: The device specified is invalid, or, if the message is INVALID 'SYSxxx', the device DEVICE 'device' FOR associated with the specified logical unit is not supported by the prccessor. Actio!!: RC = 24, except for ~SERV, which issues RC = 28. Execution of the command is terminated. The system status remains the same. 029E INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD ll..E!~~g.:!:iog: The data entered following the specified option was invalid. = 24 Execution of the command is terminated. The system status remains the same. ~1.§!~~ illi~~: RC For DMSLIO, some option Frocessing may have altered loader information. This should not affect a subsequent load. User and Action: Check the format of the field reIssue the command, specifying the data after the option. 030E FILE 'fn ft fm' ALREADY ACTIVE ~.:!:~ User Action: Reissue the command, specifying valid device name. Cr, for DMSERV, use the command LISTIO S!Sxxx to a- j!Bl~~at!£B: A file could not be referenced because it was already active. For example, this message apFears if you try to append a file to itself, or if you try to rename the EXEC file you are executing. Conversational Monitor System (CMS) Messages 117 DMS Execution of the command is terminated. The system status remains the same with the following exceptions for DMSCPY: • • • If the APPEND option was specified, and if the copying process had begun kefore the error was discovered, then records are appended to the outFut file. If the NEW FILE (the defaul~, REPLACE or OVLY option was specified, and if the cop¥ing process had tegun tefore the error was discovered, then CCPYFILE CMSUT1, on the output disk, contains the records copied so far. In multiple output file mode, several output files may have been created before the error was discovered. User Action: Use another method of execution;-or close the file and reissue the command. 031E LOADER TABLES CANNOT BE MCDIFIED Ez£l~BStiQ~: If you are trying to increase the number of loader tables, the system storage below the loader tatles is in use. If you are trying to decrease the number of loader tables, either the leader is using more tables than you specified, or the system storage below the leader table is in use. 033E FILE 'fn ft fm' IS NOT A LIBRARY EAE!~nation: For DMSSVT, the file specified in the message cannot be updated or read because the file is an invalid library. For DMSPRT, D!SPUN, and D!STYP, the !EftEBR eption is invalid because the file specified is not a library. ~l§!mg Acti.Q!!: For DMSSVT, the following issued: RC RC RC return code is 8 (if the FIND macro was issued) 10 (if the STOW macro was issued) 32 (if OSLOADER was executing) Return code 8 or 10 is passed to thE user the program continues program and executing. For return code 32, execution is terminated. For DMSPRT, DMSPUN, and DMSTYP, a return Execution of the code of 32 is issued. command is terminated. The system status remains the same. Us~± Action: For DMSSVT, check for an invalid library or an invalid fileid specification in the FILEDEF command. For DMSPRT, DMSPUN, and DMSTYP, specify a library or omit the MEMBER option. 034E FILE 'fn ft fm' IS NOT FIXED LENGTH ~§!~ Acti~: RC = 40 Execution of the command is terminated. The system status remains the same. Action: The number of loader table pages -shOUld be modified before other storage is allocated. The command should be issued immediately after IPL. Q§~ Note: If you have exceeded storage on the A-disk, reload (via IPL) without accessing the A-disk. The specified file must have fixed-length records in order for the command to be executed. !Z£1~io!!: Acti..Q.!!: RC = 32 Execution of the command is terminated. The system status remains the same. ~I§!~!! Astio!!: You may change the record format of the file by using the COPYFlLE command with the RECFM optien. Then reissue the command. ]§~~ 032E INVALID FILETYPE 'ft' 035E INVALID TAPE MODE The filetype entered valid for the command. Ez£l~D~!ioD: was not gZE1~!!S!ioD: For DMSMOD, the filetype must be lWDULE. An invalid combination of tape options was specified. For example: 9TRACK, DEN 200. For DMSSYN, the filetYFe must be SYNONYM. ~l§!~!! For DMSUTL, the filetype must be LOADLIB. RC = 24 Execution of the command is terminated. The system status remains the same. ~lli~ A£ti~: User Action: Correct reenter~e-command. the filetype and A£!ion: RC = 24 Execution of the command is terminated. The system status remains the same. User Action: Correct the tape reissue-the command. options and 036E OPEN ERROR CODE 'nn' ON 'ddname' !z£l~natio!!: An error occurred during an OS CPEN. The possible error codes are described below: 118 IBM VM/SP System Messages and Codes tMS The DSORG option of the specified DCB (data control t1cck) is not PO, PS, or DA (partitioned organization, physical sequential, er direct access, respectively). 2 The default FIlEDEF for the DCB the message 'ddname' displayed in failed. 3 The RECFM of the specified DCB does not agree with the format of the existing file, that is, one RECFM is variable-length and the other is fixed-length. 4 A DCB, BlKSIZE, IEECI, is missing or invalid. 5 The input DCB ELK SIZE is net a correct multiple of the tCE IRECl, or the output DCB specifies writing blocked output, but only untlocked output is permitted. 6 RECFM is fixed-length and IEECI does not agree with the record length of the existing file or, if the filemode is 4, the BlKSIZE dces not agree with the record length of the existing file, or RECFM is variable-length and BIKSIZE is not 4 bytes greater than the record length of the existing file, ••• , or BIKSIZE is not a multiple of LRECl whether the filemode is equal to 4 or nct. for invalid or missing DCB options. 031E [OUTPUT] DISK 'mode [cuu]' IS REAt/ONLY g~Rlg~!ioB: The filemode of the output file species a read-only disk, which cannot be written on. For DMSUPD, there was no read/write disk available for the UPDATE output files. The following steps are taken to determine the disk on which the UPDATE output 'files are to be placed (the search stops as soon as 2Bi of the following steps is successful): • If the disk on which the original source file lies is read/write, the output files are placed on that disk. • If that disk is a read-only extension of a read/write disk, the output files are placed on that particular read/write disk. • The output files are placed A-disk, if it is read/write. or EUFI eption on the If all three of the above steps fail, and the A-disk is read-only, then the message DISK 'A' IS READ/ONLY is displayed. If this message occurs during VSAMGEN EXEC processing, it indica~es that the CMS A-disk is accessed in read-only mode. Eut the VSAMGEN EXEC procedure requires that the CMS A-disk be accessed in read/write mode so that the CMS DOSLIE files can be written on it. Also, for an OS 'INSTALL', the VSAM and Access Method Services ebject modules will be copied to it for future updating. In a MAINT run for both DOS and as users, the PTF decks read frem the reader are also written on the CMS A-disk. 7 RECFM is variable-length spanned, and either the access methed is net ESAM or thefilemode is not 4. 8 An error occurred saving the BPAM directory for update, or an error occurred while doing a FIND for the member name specified in the FIIEDEF command or CMSCE macro. 9 The DCB specifies output, EDAM or a key length for an as data set or DOS file. ~I§!i! 10 An error occurred while attempting to position a tape with label type specified as BlP or NL. If this message occurs during VSAMGEN EXEC processing, the VSAMGEN EXEC procedure terminates and the system returns to the CMS command environment. 11 I/O option 'UPDAlE' is invalid file found on read-only disk. 12 80 for A tape which was specified as NL contained an IBM standard VCIl label as its first record. The file is an unsupported as data set or DOS file, or an I/O error eccurred accessing an as or DCS disk. ~s!~ !£!i2B: The program continues executing, but the DCEFIGS CPEN bit is not turned on and the DCE is not initiali2ed. USiI Action: RC = 36 Execution of the command is terminated. lhe system status remains the same. Action: Noting the error cede and ddname displayed in the message, check the associated FILEDEF command and DCB macro For DMSCPY, in multiple output file mode, several output files may have beEn created before the error was discovered. For DMSDSK and DMSRDC, the reader is closed with the HOLD option. For DMSMOD, loader cleanup performed on loaded files. has teen For DMSTPE, if the DEN, TBTCH, 7TRACK, or 9TRACK options were specified, the mode set byte has been set for the specified device (TAPi, where: i = 1, 2, 3, 4) or TAP1. User Action: Issue the CP command LINK to status. Then reset~-disk to read/write Conversational Monitor System (CMS) Messages 119 DMS access the command. disk again and reissue the 041E INPUT AND OUTPUT FILES ABE THE SAME !!£l~ng!ion: 038E One of the following errors For DMSBDP, ensure that the aFFreFriate disk is being associated with the DTF being opened, and reissue the command. was detected: • The same ddname was and output. FILEID CONFLICT '{ASM3705IASSEMBLEISYSIN}, ttNAME • The input ddname and output specify the same disk file. ddname The file specified with an ASM3705 (or ASSEMBLE) ccmmand has been previously defined by a tIIEDEF command, but its filetype was net defined as 'ASM3705' (or as' ASSEMBLl!'), or you have issued a FILEDEF command for a reader or tape input file and specified a filename that is already defined as a disk file with the filetype ASM3705 (or ASSEMBLE). • The input ddname and output specify the same tape unit. ddname FOB ~!E!gns!iQn: For the IOCP command, either: 1. the user issued a FILEDEF command for reader or tape input and the sFecified filename already exists on disk as 'fn IOCP' • 2. the user issued a FIIEDEF command for input from disk with a filetype ether than IOCF and there exists a file 'fn IOCP~ on this disk. ~lst~~ !£!!Qn: RC = 40 The command is not executed. status remains the same. ~he system ]~~I AC!!Qn: Verify that you have specified the correct filename with the ASM3705, ASSEMBLE, or rocp command. If it is correct, ~n the first case above, issue a FILEDEF ddname CLEAR command for the file, or issue a FILEDEF command that sets the filetYFe ccrrectly. In the second case, either use a different filename for the input file, or erase the existing disk file. specified for inFut ~I§~~!! Act!QB: BC = 40 Execution of the command is terminated. The system status remains the same. User Action: Reissue the MOVEFIL~COmmands correctly. FILEDEF and 042E NO FILEID[ (S) ] SPECIFIED ~!~~tion: At least one file identification is reguired in order fer the command to be executed. A£!!QB: RC = 24 Execution of the command is terminated. The system status remains the same. ~I§!~!! User Action: Reissue the speCifyIng-at least one fileid. command, 043E 'TAPn(cuu)' IS FILE PBOTECTED !!£lgna!ioB: The tape cannot be written en. Systg Action: RC = 36 Execution of the command is terminated. If the DEN, TRTCH, 7TRACK, or 9TRACK oFtions were specified, the modeset byte has been set for the specified device (TAPn, where: !!= 1, 2, 3,4). ~§~I !£!ion: Send a message to the operator to insert the write enable ring in the" tape and retry the command. 039E NO ENTRIES IN LIBRARY 'fn ft fm' ~!E!gngtiQn: The library specified contains no members. !£!iQn: RC = 32 Execution of the command is terminated. The system status remains the same. For DMSCLS, verify that the correct tape is mounted • .§.Ist~m US~I ~~E!~ng~iQn: Action: None. 040E NO FILES LOADED ~AE!2nstion: The user has not previously issued a LOAD MOD or LeAD command, or the module consists of zeros. ~1..§!~!! !cti.2n: RC= 40 Execution of the command is terminated. The system status remains the same. User Action: Load iOADMOn-cOimand. 120 044E RECORD LENGTH EXCEEDS ALLOWABLE MAXIMOM files via the lOAD IBM VM/SP System Messages and Codes The record length given exceeds the maximum recerd length allowed. The maximum record length allowed by the EDIT command is 160 characters; by the PRINT command, 151 characters; and by the PONCH command, 80 characters. Action: RC = 32 Execution of the command is terminated. system status remains the same. ~~!~!! ~he Oser Action: For DMSEDI, reissue the command with an acceptable record length. or For DMSPRT and DMSPUN, you can change the record length with the COPYFILE command, DMS and then reissue the command. specification with the the DLBL command. 045E UNSUPPORTED 370X CONTRCI ERCGEAM TYPE MULT option of • The 3705 cortrcl Frogram type is not an Emulation Program (EP), Partitioned Emulation Program (PEP) or Network Control Program (HCP). The mode specified with a LISTDS command was not the mode of an OS or DCS disk. • The mode specified with a LISTIILE command was not the mode cf a CMS-formatted disk. ~.!§.l~J! Acti.Q!!: RC = 16 Execution of the command is terminated. §1§~~J! User Action: Make sure that 370X control program--has been generated with correct parameters. For the cor:rect parameters for the 370X control program generation, refer to the VMa,g ,gls}J!,Di,D.9 .2,D.9 .§lst~J!j 2~!~.!lli:j2! Gui.9§· For DMSTPE, if the DEN, TRTCH, 7TRACK, or 9TRACK options were specified, the mcdeset byte has been set for the specified device (TAPi, where: i: 1, 2, 3, 4) or TAP1. ~Xflanati.Q!!: A£!i:j2!: RC = 24 Execution of the command is terminated. The system status remains the same. 046E NO LIERARY NAME SPECIFIED The command without a library name. was ~l~nation: entered ActiQ!!: RC = 24 Execution of the command is terminated. The system status remains the same. ~.I..§!~! User Action: Reenter the specifying the library name. command, User Action: Reissue the command filemode-Specified correctly. with the 049E INVALID LINE NUMBER 'line number' 11]~g!.2tion: either zero file. The specified line number is or outside the limits of the §1§!~J! Acti:~: RC = 24 Execution of the command is terminated. system status remains the same. ~he User Action: Examine the file and reissue the-command with a correct line number. 047E NO FUNCTION SPECIFIED A function must be sFecified in order for the command to be executed. ~zE!~~atiQ!!: Acti.Q!!: RC = 24 Execution of the command is terminated. 050E PARAMETER MISSING {DDNAMEISYSxxxlfunction} AFTER ~.l§te! For SVCTRACE, SVCTRACE is was on. EX]].2]@!i~: 1 parameter that is reguired by the command was not specified. turned off if it For DMSTPE, if the DEN, TRTCH, 7TRACK or 9TRACK options were specified, the modeset byte has been set for the specified device (TAPi, where: i: = 1, 2, 3, 4) or TAP1. Otherwise, the system status remains the same. User Action: Reissue the command desired function. with the For the ISSGN command, the disk mode must bE specified fo~ the SYSxxx logical unit. For the DLBL command, the disk mode or DUMMY or CLEAR must be specified after the ddname. For the FILEDEF command, the device name or DUMMY or CLEAR must be specified after the ddname. For the SET command, a reguired Farameter that must follow a function is missing. 048E INVALID MODE 'mode' Exf1anation: This message can occur for an} one of the following reasons: SIste..!!! Actio!: RC = 24 Execution of the command is terminated. The system status remains the same. • The mode was not specified correctly. User Acti~: command. • For most CMS commands, file mode an invalid mode. • The mode number, if between 0 and 5. • More than two for the mode. • A null line IS' specified, is as the and reissue the is not characters were specified was entered Correct first OS1E INVALID MODE CHANGE jxelanation: The filemode letter specified for the old fileid is not the same as the filemode letter specified for the new fileid. 24 Conversational Monitor System (CMS) Messages 121 DMS Execution of the command is terminated. The system status remains the same. User Action: 'Comma n-d-.--- Correct and reissue the command, resetting the size of the DOS partition. Redefining the partition size causes storage to be reinitialized and any previous loads or fetChes must be reissued. §Y'§!~!!l Actig~ 052E MORE THAN 100 CHARS OF OP!IONS SPECIFIED EX]!g~ation: The maximuID numter of characters that can be used tc s~ecify options for this command is 100. More than 100 characters were used. For the OSRUN command, more than 100 characters were used in the PARM field. .!£.:tism: RC = 24 The command is not executed. status remains the same. .§I2!~!!l The system Us~ Ac~igB: Reissue the command, using 100 or fewer characters to specify the cptions, or parameters. Use atbreviations if necessary. 053E INVALID SORT FIELD PAIR DEFINED Either an ending character position was not specified for a sort field, the starting position is greater than the ending Fositicn, the fields contain nondecimal characters, or the sort field exceeds the maximum of 253 characters. ~!]!g~tigB: Acll2B: RC = 24 Execution of the command is terminated. The system status remains the same. .§:i'§!~!l User Action: coiiiiiiand:--- Correct and reissuE the 054E INCOMPLETE FILEID SPECIFIED You must specify the filename and filetype in order fcr the ccmmand to be executed. In addition, for scme commands you must specify the file mode. Re = 40 Execution of the command is terminated. Loader cleanup has been performed on loaded files. This should not interfere with a subseguent START command. User Action: If no file was previously loaded, issue the LOAD command specifying the files to be loaded. If files are loaded, check them for incorrect SLC or entry cards • 056E FILE 'fn ft [fm]' CONTAINS INVAlID {NAMEIALIASIENTRYIESD} RECORD FORMATS For DMSLBM and DHSNCP (GEN, ADt, REP), the specified file is Dot in the expected format. MACRO and MEND cards must te included in the HACRO files f and the prototype card must be s~ecified with a name that does not exceed eight characters. If an © statement appears, it mU$t contain a name. A HACLIE must contain 'LIB' in columns 4-6 of record onE. j!]1s~atio~: For DMSLBT, the specified file has more than 255 entry points (ESD only), or has records which are incompatible ormissing~ For DMSLIO, an invalid condition was ~ound in a TEXT or TEXTLIE file. 1XTLIE ~ile~ created on EDF disks must have "PDS" in columns 4-6 of record one. TXTLIE file$ created on non-EDP disks must have "LIB" in columns 4~6 of record one. RtD data must be compatible with the ~EXT file or iXTLl5 member to which it belongs. If an IeS statement WaS SUbmitted, the specitied name was previOusly defined, or the initial length of the CSECT was not found in the ESD card. ~!£!g~g!iQl!: = 24 Execution of the command is terminated. The system status remains the same. .§ill§!!! ActigB: RC JL§£I ActiQ!!: Check the description of the command, correct the command line, and reissue the command. 055E NO ENTRY POINT DEFINED For the START command or the START option of the FETCH, lOAD, or INCLUDE command, either the initial execution address is zero, or there is no eXEcutable code at the execution address, or nothing has been loaded. J!~!snation: This message is also issued if a START command (or FETCH command with the S~ART option) is issued following a SET DCSPART 122 IBM VM/SP System Messages and Codes For DMSSYN, the specified file is not in the expected format. The SYNONYM file must contain 80-byte records in free f9rm format, with columns 13-80 ignored. The data consists of a command name fcllowed bl a blank and the user synonym. This may optionally be followed by a count which is preceded by at least one blank. For DMSZAP, either the header record for TXTLIE or LCADLIE was invalid, or the pointer to the directory or module map was in error. A£si2n: RC = 32 Execution of the command is ter.inated~ The system status remains the Same. For DMSGLE, the library is not globaleo and t~e operation continues for any other libraries named in the command. ~I§!~~ User Action: For DMSLEH and DMSNCP, issue MAtLIB COMP command, then check the MACLIB with a HACLIE MAP command. Ccrrect the format error. the- DMS For D!SGLB, the specified 1i~rary does not have "LIB" in columns 1-3 or 4-6 of the first record. One possit1e cause is the 1itrary may be in packed format. Correct the library and reissue the command. ~§!I For DMSSYN, file. For DMSTPE, if the position of the tape "is not as expected, use the appropriate TAPE control function to reposition it. " correct the For DMSLIO, recreate file. the format ~XTIIB of or the A£tion: For DKSTPD, you may space the tape forward and continue, or rewind the tape and quit; this can ~e an information message rather than an error conditicn, depending on the circumstances. TEXT For DMSLBT, if the message specifies ESD, check for more than 255 entry points for a member; otherwise, check for invalid or missing records. For DMSBOP, ensure that the proper tape has teen mounted. If so, rewind and repositiQD the tape and retry. For DKSCLS, rewind and reposition the tape and reissue the command. For DMSZAP, recreate the library or module. 059E 'cuu' ALREADY ACCESSED AS READ/WRITE tmode' DISK. Then reissue the command. 056W FILE 'fn ft fm' CON~AINS INVALID {NAMEIALIASIENTRYIESD} RECORD FORMA~S ~!]lanation: The specified file is the expected format. ~st~~ not in A£tiQB: Processing continues. l1.Elanatioll: You are trying to access the specified device in read-only mode, but you have already accessed it read/write mode. You cannot have a disk accessed as beth read-only and read/write, because the read-only file directory would not reflect any updates you made until the next time you accessed the disk. A£!i21l: RC = 36 Execution of the command is terminated. The system status remains the same. ~l§!~! 057E INVALID RECORD FORMAT Ex]l~tion: For the TAPE command, a record that was read was not in ~APE DUMP format. For the TAPEMAC command, the tape was not in the IEHMOVE unloaded PDS format, or the PDS logical record length is not 80. .§lst2 Ac!iQB: RC = 32 Execution of the command is terminated. For the TAPE command, if the D!N, TRTCH, 7TRACK, or 9TRACK options were specified, the modeset byte has been set for the specified device (TAPi, where: i = 1, 2, 3, 4) or TAP1. User Action: For the TAP! ccmmand, rewrite the- file-onto tape using the TAPE DUMP command. For the TAPEMAC command, recreate the file on tape using the os IEHMOVE utility program. Then reissue the command. 058E END-OF-FILE OR END-OF-TAPE [CN 'TAPn'] EX~~2B: The end of the file User Action: Release the disk by issuing the-RELEAsi command and then reissuE the ACCESS command. 060E FILE(S) 'fn [ft [fm]]' NOT FOUNt. 'mode (cuu)' WILL NOT BE ACCESSED DISK 1!.E!§~g~ioll: The files requested were not on the specified disk or if the disk contains no files and you accessed it as an extension, your access fails; therefore, the disk is not accessed. If another disk was already accessed as mode "fm", it is released. ~nte~ !cti2~: RC = 28 Execution of the command is terminated. ~he system remains in the same status as before the command was entered. User Action: Check to see that the fileid Is-specifIed correctly, and reenter the command. or tape was reached. 061E NO TRANSLATION CHARACTER SPECIFIED For DMSTPE, an end-of-tape condition was encountered while dcing a write, iTM (write tape mark), or ERG (erase gap) operation. Actism: RC = 40 Execution of the command is terminated. For DMSTPE, the last operation is not completed. The tape is Fositioned at the end. If the DEN, TRTCH, 7TRACR, or 9TRACR options were specified, the modeset ~yte has been set for the spEcified device ~APi, where: i = 1, 2, 3, 4) or ~AP1. ~st~ j!J2!gllgtioll: A SET INPUT or command was issued without a character. SIT CUTPUT translation ..tt§m j£!ion: RC = 24 Execution of the command is terminated. The translate table remains unchanged. User Action: Reissue the command with the appropriate translation character. Conversational Monitor System (CMS) Messages 123 DMS 062E INVALID [CHAR] '[=I*lcharICHARACTER)' [OUTPUT] FILEID ['fn ft [fm]'] EXElanatiQB: The character specified whether an asterisk (*), equal sign (=), or other was invalid in the fileid in which it appeared. Syst.!!l.!!! ActiQl!: RC = 20 Execution of the command is terminated. The system status remains the same, with the following exceptions for the COPYFILE command: • • • If the APPEND option was specified and the copying process tegan tefore the error was discovered, then records were appended to the output file. If the NEWFILE (the default), EE~LACE, or OVLY option was specified, and the copying process tegan before the error was discovered, then COPYIILE CMSO!1, on the output disk, contains the records copied so far. In multiple-output-file mode, several output files may have been created before the error was discovered. ~§.!!lI A£!igB: Check the description of the command format and reissue the command. LIST 063E NO [SORTITRANSLATIONISPECIFICA!ION] {ENTERED I GIVEN} than nne IN Ex]ls~tiQB: A list was requested in response to the SOBT command, or to the SPECS option or TRANSLATE option of the COPYFILE command, but a null line was entered in response. The XEDI! sutcommand SORT was entered with no sort fields specified. ActiQB: RC = 40 Execution of the command is terminated. The system status remains the same. ~.I§.!em ActiQB: Reissue the ccmmand, and enter the list when it is requested. • A string was specified without an ending delimiter. • A zero length string was specified. • An invalid hexadecimal number was specified, or an odd number of hexadecimal digits followed the "H" of such a specification. • The continuation code (++) was specified in the middle of a specification, rather than at the beginning of one. Some of the errors that can cause this message to appear in conjunction with the TRANS option are the fo~lowing: • An invalid entered. • An odd number of characters was entered. • The continuation code (++) was entered in the middle of a character pair. hexadecimal number ..21.§!n jction: RC = 24 Execution of the command is terminated. system status remains the same. was ~he Oser Action: Reissue the command and enter the-correct specification list when it is reguested. 065E 'option' OPTION SPECIFIED TWICE j]]lanatioB: The option was specified more than once in the command line. .§1.§.!n j c ti2.!!: RC = 24 Execution of the command is terminated. The system status remains the same. command, Oser Action: Reissue the specifyIng-the option only once. Q§.!!l~ 064E INVALID [TRANSLATE] NEAB 'list' SPECIIICA!ION AT OR Ex]lanation: An invalid specification was included in the list entered when either the SPECS option or the TRANS oFtion was specified. "list" is the Fortion of the list you entered that is in errer. Some of the errors that can cause this message to appear in conjunction with the SPECS option are the following: 124 • A source specification was entered with no target specification. • An invalid decimal number was for an input or output column. • An input file specification of the form "nn-mm" was given, but mm was smaller IBM VM/SP System Messages and Codes entered 066E 'option' CPTIONS AND 'option' ARE CONFLICTING The specified options mutually exclusive and must not specified in the same command. ~]lsl!s!iol!: are te .§.I§I.!!l.!!! !£!i2B: BC = 24 Execution of the command is terminated. system status remains the same. ~he Correct the .!!§.!!lI Ac!i.Q.!!: command. 061E COMBINED INPUT UNPACK OPTIONS and reissue FILES ILLEGAL WITH PACK OR An attempt was made to comtine several files at the same time that the PACK or UNPACK option was used. This message appears if there is more than one input fileid, or if there is an asterisk in !~Elg~ioB: DMS the first mode. fileid in single output file ActiQ.!!: RC = 24 Execution of the command is terminated. The system status remains the same. ~.!§!~!!! User Action: Correct the command reissue the command. line and 068E INPUT FILE 'fn ft fm' NeT IN PACKED FCRMAT ]X£l~atio~: The specified input file is not in packed format, and was specified in an UNPACK operation. RC = 32 Execution of the command is terminated. The system status remains the same, except that in multiple output file mede, several output files may already have teen created before the error was discovered. ~~§!~ !£!iQ~: User Action: Correct the command reissue-the command. line and reissue the cemmand. 071E ERASE * * [fml*] NOT ALLOWED ~~lanatiQn: You cannot erase all files on all disks using the ERASE command. Yeu can enter asterisks for the filename and filetype, but you must specify the filemode letter and number. RC = 24 Execution of the command is terminated. The system status remains the same. §l§!~!!! A£!iQ~: User Action: Issue the FORMAT command to on a disk, or use the ACCESS command with the ERASE option (all files on the disk are erased the first time yeu write a new file on the disk). erase--al~files 072E ERROR IN EXEC FILE fn, LINE nnn - message ]zBlsng!iQn: The EXEC interpreter has found an error in file 'fn', at line "nnn". 'message' may be anyone of the following: CMS EXEC Return Codes: 069E DISK {'mode'l 'cuu' I 'volid '} NOT ACCESSED EXElg~g!ion: The specified disk has not been accessed. For DMSDSL, the A-disk must be accessed when the DOSIIE MAP function is performed and the output is directed to disk. Ac!iQ~: RC = 36 Execution of the cemmand is terminated. The system status remains the same. ~~st~!!! User Action: Access the reissue-the command. specified disk and 0691 [OUTPUT] DISK 'mode' NOT ACCESSED ]Zflg~g!iQ~: The disk specified in FILEDEF command has not been accessed. ~~§!~!!! ActiQ~: information only. the This message is for Execution continues. 070E INVALID {PARAMETER 'argument'} 'parameter'IARGUMENT EXf!~atiQ.!!: An invalid operand, or too many or extraneous operands, were specified in the command line or EXEC statement. RC = 24 Execution of the command is terminated. The system status remains the same, with the following exception for the TAPE command: ~ill!!l AcliQ~: If the DEN, TRTCH, 7TRACK, or 9TRACK options were specified, the modeset byte has been set for the specified device (TAP i, where: i = 1, 2, 3, 4) or TAP1. ~~ !£!ion: Correct the command line and FILE NOT FOUND BC = 801 The specified file was not found on the accessed disks. This message can be issued when you try to invoke an EXEC from within another EXEC. &SKIP OR &GOTO ERROR Re = 802 A reguest was made to move to a statement atove the beginning of the file, er tc a nonexistent label. BAD FILE FORMAT Re = 803 The file is not in the reguired format. For instance, it is packed rather than unpacked, or the record length is greater than 130. TOO MANY ARGUMENTS RC = 804 A maximum number of 30 passed to an EXEC file. arguments can MAX DEPTH OF LOOP NESTING EXCEEDED RC = 805 No more than four nested loops specified. ERROR READING FILE RC = 806 An I/O error occurred was being read. INVALID SYNTAX RC = 807 The syntax of the invalid. while an may be be EXEC file indicated statement is INVALID FORM OF CONDITION RC = 808 This can occur from previously unassigned variables. The final result after the line Conversational Monitor System (CMS) Messages 125 DMS is interpreted is syntactically invalid. INVALID ASSIGNMENT RC = 809 An attempt was made to assign a value to an unspecified field; for exam~le. = SPECIAL CHARACTER IN VARIABLE SYMEOL RC = 819 A special character was used in a variable symbol. Only alphameric characters are to be used. The asterisk in the special variable s* is an acceptable character. 42 Ac!ign: The file is executed up to the point where was detected. logically the error Action: reexecute-it. file ~I§!~! MISUSE OF SPECIAL VARIABLE BC = 810 Incorrect use of a sFecial varia tIe was attempted. For example, an attempt was made to assign a value to SEXEC or to STYPEFLAG. QE~~ Correct the EXEC and ~2!~: ERBOR IN SERBOR ACTION Re = 811 An SERBOR control statement specified a CMS command that also resulted in an error. CONVEBSION ERROR RC = 812 A variable in the line must be converted, but cannot be, because it is a character value, it is not in the proper format, or it has not been initialized. For examFle, If SFLAG was not previously initialized, it is "null" or blank and will cause a conversion error when being converted to decimal. This message is also issued if a nonhexadecimal number is sFecified after the characters "X'" on the right-hand side of an assignment statement (for examFle, SA = X'12AG'); or if a nondecimal number is specified after the characters "X'" in any statement other than an assignment statement (for example, STYPE X'120AO'). a single EOF FOUND IN LOOP RC = 815 An end of file occurred before the command completed the requested oFeration. INVALID CONTROL WORD RC = 816 An invalid control word was encountered in the input deck and cannot be r€ad. EXEC ARITHMETIC OVERFLOW RC = 818 A positive arithmetic variable digits. ]~~1snatioR: CMS was unable to open the specified ddname. An explanatory message should appear along with this message. !cti.2.!!: RC = 28 Execution of the command or program is terminated for the OS Loader. Abend code = 15A for LINK/LOAD/ATTACH/XCTL failures. BC=28 for OSBUN command. Q~~ Ac!ioR: Verify the ddname and reissue the command. If using the OS Loader, verify that the LOADLIB libraries in the GLOBAL list exist. 074E EBROR [RE]SETTING AUXILIABY DIRECTORY ]~~1s~atig~: MISUSE OF BUILT-IN FUNCTICN RC = 814 One of the EXEC built-in functions (for example, SCONCAT, SDATATYPE, etc.) was used incorrectly. EXEC ARITHMETIC UNDERFLOW BC = 817 A negative arithmetic variable digits including sign. 073E UNABLE TO OPEN FILE ddname ~lli~ 'SIF SFLAG EQ 944' TOO MANY TOKENS IN STATEMEN! RC = 813 More than 19 tokens aFpeared in SREAD VARS statement. For a tutorial description of the CMS EXEC facility, see the VML~g ~~~ Q§§~§ Guide. For a description of the eMS EXEC control statements, see the VML~g ~~~ Command .9!!.Q ll.9crg ~§fe~§~. exceeded 8 The auxiliary directory could not be set or reset. This can occur, for example, if the disk on which the auxiliary directory resides is not accessed when the command is issued, or if it is accessed as a filemode other than the one specified for it with a previous GENDIBT command. RC = 40 If the error occurred on an attempt to set the auxiliary directory, execution of the command is terminated. The system status remains the same. If, however, the error occurred on an attemFt to reset the auxiliary directory, the assembly has already been done, and execution continues. ~1§!~~ !ctig~: Q§~~ A£!igB: Consult the system Frogrammer to find out what disk the auxiliary directory is on and what filemode that disk should be accessed as. (It should have the file mode that was specified for it with the GENDIRT command.) Access the disk with the proper filemode and reissue the command. 075E [DEVICE] devicename {INVALIDIILLEGAL} {INPUT 10UTPUT} exceeded 8 ]AE1~BatioR: input or 126 FOR IBM VM/SP System Messages and Codes The device specified for the outFut ddname is invalid. This DMS Jessage will appear if the input device specified is DUMMY, PEIN~EE, or PUNCH, or if the Qutput devicE specified is READER, CRT, OS DISK, or DOS DISK. .2.I§!~!!! AgtiQ!!: RC = 40 Execution of the command is terminated. The system status remains the same. !!.§g !£.t.i&.n: Reissue and specify device. the the FILEDEF cemmand corrEct input/output 076E ACTUAL RECORD LENGTH EXCEEDS THA! SPECIFIED 078W SEQUENCE ERRCR DETECTED LOADING 'fn EXPECTED ••••••• FOUND , •••••• !lR!sBatioB: 7he seguence number not the next sequential number • Action: been loaded errors. ~§§& Check the file after is has for possible transmission 079E INVALID DEVICE ADDRESS - REENTER The device address entered was specified incorrectly, that is, it is not a valid hexadecimal character or is net in the range of X'001' to X'6FF'. !~l~!!atio!!: Agtion: RC = 40 Execution of the command is terminated. The system status remains the same. ~1§!§.!!l §l§.t~!!! User Action: Reissue specifyIng-a-larger record tRECL option. the command, length with the DMSINI606R or See DMSINI606R or DMSINI608R. The value entered valid decimal number. §..I§!§!!! !£ll.Q!!: RC = 32 Execution of the command is terminated. The card file is lost from the reader. ~ystem reissued. ]§§~ Acti.QB: Message was not DMSINI609R a is !£!i.QB: See DMSINI609R. 081E INVALID REPLY - ANSWER "YES" OR "NO" DUH~ command must be issued to recreate the file. IN ~~ !~: ~lanat~B: llR!anation: Since the end card is missing, the input file is not complete. 7he deck is pro~ably invalid. 078E INVALID CARD 'cardimage' } Acti~: Message DMSINI608R is reissued. 080E INVALID {CYIIELK} NUMEER - REENTER 077E END CARD MISSING FROM INPU! DECK Y§§I !£!i.Q!!: The DISK found is ~1§!§!!! !s!i~!!: RC=32 The file continues to be loaded. I!R!~~~: An existing file has a record length greater than the record length entered in the command line. ft' EEAIlEE ~~l~ion: guery is entered. The only valid response to the "yes" or "no". Neithe~ was {tECKIFIL! !!]~!i.Q!!: For DMSDSK, a card that was not punched by DISK DUMP was encountered in the input deck. The dECk cannot te rEad by DISK LOAl). ~1§!§!!! A£!i~!!: Message DMSINI610R is reissued. ~§§& !£1i~: ~lBl~!!~tion: See DMSINI607R or DMSINI610R. Acll.2D: RC = 32 Execution of the command is terminated. The system status remains the same. ~1§!§!!! The device is not currently defined, or it is not in ~ead/write status, or it is an unsupported device type. ~.§.!:§.!!l !!.§~ AS( ti.sm : For DMSDSK, reissue the command in case there are valid DISK DUMP cards fellowing in the file. If the same error occurs, either retry, use the READCARD command to load the file, or USE the CP PURGE command to erase the reader file. For DMSGRN, use the card image in the error message to correct the card, and reenter the command. or 082E IPL DEVICE ERROR - REENTER For DMSGR~, an invalid ca~d was encountered ;i.n theinpllt deck. The deck cannot be processed by the GEN3705 command. For DMSDSK, the READER file closed with the HOLD option. DMSINI607R ~eissued. Q§~! Action: Message DMSINI608R is A£!i2!!: See DHSINI608R. {CYLIBLK} 083E NUCLEUS UNACCEPTABLE EBROR 'X' SPECIFICATICN The cylinder or FB-512 block number specified fo~ the nucleus start address does not meet the requirement indicated by the error code. EXE!s~~!!: Code ,Hganing 1--- The nucleus will overlay CMS files on the minidisk. Conversational Monitor System (CMS) Messages 127 DKS 2 The nucleus start address all formatting_ 3 The starting FB-512 tloo~ nu.te~ not on a 256-tloc~ toundarl~ 4 A total pf 256 FB-512 blocks aXe not available, including tbe etartln~ block number. §l!~ reissued. !£tio~: 1s teyQ~4 ~s tMSINI609~ Message Agtion: If ac = 1, ~eSFond to DMSINI609R with a largEr cylinder value or FB-512 block number. If Re = 2, sFeclfy a smaller value. If Re = 3, specify ~ multiple of 256. If RC = 4, specify a lower location for the nucleus. In a~y event, use of the FORMAT command with the RJCOMP option may be necessary_ During a scan for a not located. latel, the latel INVALID VABIABLE NAME RC ;::: 10007 A word without a leading ampersand found in a place where a variable expected. ~as wa~ Was INVALID fOBM CF CONDITION BC ;: 10008 Either the conditional operator is inv~li4 or one of the operands has a null value~ Q!~ 084E INVALID USE OF 'FROM' AND '!C' CPTICNS lJR!!D~2D: The 'FECM' location exceeds is equal to the 'TO' location. .§I!.:!:!U!! A£ll.2.!!: RC = 24 or Execution of the command is terminated. system status remains the same. T~~ Correct the !ctiOB: co IDID an d. Q!!X and reilEleue OSSE ERROR IN fn ft fm, LINE nnn - messagE MISSING ARGUMENT RC = 10010 A reguired argument is missing. INVALID ARGU8ENT BC = 10011 An argument has an invalid value • CCNVEBSION ,EBBOR BC = 10012 An error has occurred in cODverting fro. string to a ~umeric value. ~ NUMERIC OVERFLOW BC = 10013 A number has overflowed the defined syste. limi ts: (2.*32) -1 or - (2**32) • EXEC 2 Return Codes: INVALID FUNCTION NAME RC = 10014 If the function name starts with an ampersand, it is not a predefined funct1Qn, or if it starts with a dash, it is pot a label in the file. FILE NOT FOUND RC = 10001 The input file accessed disk. END Of FILE FCUND IN LOOP RC :;: 10015 The end of tbe file was found end of the loop. !lR!!D!!i.2.!!: The iXEC 2 interpret"fu; ~as found an error in file "fn ft fm", at lipe "nnn". "message" may be apy ODe ot ~he following: . was not located on an WRONG FILE FORMAT RC ;::: 10002 The line length exceeds 255 bytes. tIVISION BY ZERO Be ;: 10016 A division ty zero was detected. WORD TOO LONG RC = 10003 An attempt was made to assign more tban 255 bytes to a vari~ble, or a word in a line i~ longer than 255 bytes. INVALID LOOP CONDITION BC :;: 10017 The conditional expression in statement has an invalid format. S!ATEMENT TOO LONG RC = 10004 The length of the bytes. statement excEeds ~11 INVALID CONTROL WORD RC;::: 10005 A word with a leading amBarsand was foun4 where a control word was expected, ~ut it is not recognized as a control word. LABEL NOT FOUND RC ;::: 10006 128 INVALID ASSIGNMENT BC ;::: 10009 An operator in an assignment statement is not (), or (-), or 'of'does not follow the function name. IBM VM/SP System Messages and codes tEfore tbe an Steef ERBOR BETURN DUBING SERRCR ACTION BC ::: 10019 An error has occurred during execution of the action specified on an S.8808 statelDent. ASSIGNMENT TO UNSET ABGU8ENT BC ;: 10020 An attempt was made to assign a value to an argument when the number of that argq.ent exceeded SN. For examFle, SARGS A E C S4=D DtlS would cause this error. 086E INVALID PDNAME 'ddnams' STATEMENT OUT OF CON~EX! RC :;: 10021 &RETURN ,as encountered when no sutrQutlne was active. INSUFFICIENT STORAGE AVlILABLE RC :;: 10097 Insufficient storage to complete statement. tbe This may be caused by SSTACK, assignment to a variable, or other actions that rEqu~re additional storage. FILE READ ERROR nnn Re :;: 10098 The operating system was u~atle to read the file or some part of the tile. The return code "nnn" indicates one of the following conditions: £2~L11!!n!ag 1 2 3 5 7 8 9 11 12 13 14 15 The file was not found. The address of the tuffet Was not within virtual storage limits. A permanent disk errer cccurred. This may occur if you link to and access another user's disk, then try to read a file that was refiled by its owner after you issued the ACCESS coamand. Reissue the ACCESS command and try to read the number again. The number of records is less than 0 or greater than 32768. The fixed/variable flag is not P or V. The record read is longer than the buffer. The specified file is open for writing; it must be closed and opened for reading. The number of records is greater thap 1 for a va~iable-1Ength file. The end of the file was reachEd. An invalid displacement appears in the AFT for a variable length file. An invalid character appEars in the filename. An invalid character appears in the filetype. TIUCE ERROR nnn RC ;= 10099 A command or subcommand issued as an 8qtion of STRACE returned .the error code 'nnn'. Execution of the current EXEC 2 file is terminated. §l~U !£!,!.QIP The file is executed up to the point wherE was detected. !ctign: Correct the reexecute it. ~!X EXEC 2 logicall, the er,ror file and !2!! For information on EXEC 2, sse the !!L§R JlJ£ 1 !!:!~!n~!· j1R!!!J!ign: The ddname command is invalid. specified with the RC = 24 Execution of the command is terminated. the system status remains the samE. ~I!1!! A~n: Action: Reissue the command with a valid ddname. With the DLBL command, USE ~ ddname of seven characters or less. If you are an OS user, enter the first seven characters of your program's ACB ddname. If these seven characters are not unigue within the program (that is, the eighth character distinguishes two ACBs in the same program), recompile the program using different ddnames. ]§~ 096W DLBL 'ddname' DUMMY INVALID FOR VSAM !!]l!BA!ion: The ddname in the !CB being opeued w~s specified in a previous DLBL command with the DUMMY operand, which is invalid for VSAM. !£lisn: BC = 8 This message accompanies a DOS/VS VSAM open error code X'11'. The OS user is restricted from using a DUMMY VS!! data set. An attempt to do so will cause unpredictable results at OPEN time. An additional message from the program product teing used may follow~ ~I§!!! Action~ Reissue the DLBL command specifying a lode for this ddname, and then restart the program that caused the error. ~I 087E INVALID ASSIGNMENT OF 'device' 'SYSxxx' TO DEVICE ~!]l!B!ti~n: The e~tered violated AS5GN command that was a restriction on th~ assignment of 5YSxxx to a virtual device. ~he ASSGN command restricts the assignment of logical units to virtual dEvices as follows: SYSLOG SYSL5T SYSIPT SYSPCH SY5RDR SYSCAT SYSCL~ SISRLB SYSSLB SYSIN SISOUT Valig !.!§ID.!!!ill to any device as speCifiEd by the A5SGN command. to terminal and printer to printer, disk, and tape to reader, disk and tape to punch, disk, and tape to reader, disk, and tape to disk to disk to disk to disk to reader, tape, and disk to tape Action: RC = 24 of the command is terminated. The system status remains the same. .uslu Executi~n Use, ~tion: Reissue the A5SGN command, specifying a valid combination of logical Conversational Monitor System (CMS) Messages 129 DMS condition. processing direction. unit and virtual device. CMS/DOS supports tape only in a fcrward 088E UNSUPPORTED DTF TYPE 'atftype' ~~fl!nstig~: close a DTF by CMS. 11 An attempt was made to open or close a DTFMT (tape data fil~ and 'ASCII=YES' was specified in the DTF macro. Tbis operand is not supported. 12 An attempt was made to open a DTFCP or DTFDI tape file with 'FILABL=S~D' specified. However, no VOL1/HDE1 was encountered. 13 PUB information for the tape logical unit being opened (track mode indicator or density) is incompatible with the tape drive. 14 The tape is a 3420 tape drive but an invalid tape drive model number (valid model numbers are 3, 4, 5, 6, 7, and An attempt was made to o~en or table of a type nct supported .§.I.§!~!!! ]£ti.Q,n: RC = 24 Execution of the command is terminated. The system status remains the same. Q.§~~ !ctig~: None; CMS/Des only supports those DTF types identified in the CMS/DOS publications. 089E {OPENICLOSE} ERROR {fn I SYSxxx I TAPn} CODE Inn' ON EXE!~!iog: The error code in the message identifies the error situaticn. fg£~ .tl~.9~ing 1 The logical unit (SYSxxx) in the DOSCB does not match the lcgical unit in the DTF table. 2 CMS/DOS does not support writing to OS or DOS disks. All files must be written to CMS disks. 3 4 5 130 An attempt was made to open or close a seguential disk file, VSAM file, or private source statement litrarj, but no DLBL command was issued with the DLBL ddname egual to the rTF ACE filename. CMS/DOS reguires a user-issued DLEL for all seguential disk files, VSAM in~ut and cutput files, and private libraries. An attempt was made to open or close a DTFCD or DTFPR with ASOCFLE/FUNC operands specified in the DTF macro. These operands are net suppcrted under CMS/DOS. An attempt was made to open seguential disk file from an but no extent information was the OSPST associated with the an input 8) • 15 While opening a DTF associated ~ith a file on an OS or DOS disk, an I/C error occurred while reading the extent information for the specified data set. 16 SYSIPT/SYSRDR is assigned to tape and the record length is not 80 or 81 bytes. 17 An unexpected error situation was encountered while performing a tape I/O operation. 18 The SA! OPEN/CLOSE (in the CMS/DOS environment) routines have returned with an error indicating that the DTF currentlr being processed could not be opened because of a lack of virtual storage. 19 An attempt was made to OPEN a SA! file in VSAM space. This feature is not supported in CMS/DOS. 20 to fetch an An attempt was made invalid or unsupported VSE/AF OPEN transien t area. 21 For MOVEFILE to process a tOS input file on FB-512 devices, the RECFH and BLOCK must be specified on the input FILEDEF for nne For a fixed clock RECFH, the LEECL also must be specified. as disk, found in file. 6 An attempt was made to open a seguential disk file for input, but the file was not found on any of the acc<;!ssed disks. 7 The device type in the DTF being opened or closed is incom~atitle with the PUB device type for the specified unit. 8 The system or is unassigned X' FF') • programmer logical unit (PUB ~ointer in LUB 9 There is no CMS/DeS support for reading tapes tackward. When the operand READ=BACK is specified on the DTPMT macro, a flag is set in the DTF at compilation time indicating this IBM VM/SP System Messages and Codes ~1'§!~!!! !£!i£B: RC= 36 Execution of the command is terminated. The system status remains the same. User Action: Correct the the-cOiDiDaiid. 090E INVALID 'device' DEV~CE !~E1:.9nslli.!!: CLASS error and reissue 'deviceclass' FOE The device class inforllation returned from the CP DIAGNOSEreguest (code DMS 24) conflicts assigned. with the device being 095E INVALID ADDRESS 'address' ~!Els~tion: !£li2!!: RC = 36 Execution of the command is terminated. The system status remains the same. The specified address is not within the range of the virtual machine, is not a valid storage address, or is not egual to or greater than X'20000'. User Action: Reissue the command. If this faIls;-call IBM for softwaIe support. .aY§tem Acti~B: RC = 100 Execution of the command is terminated. The system status remains the same. .§.Ist~.!!l 091E SAVEAREA ADDRESS IN PAR!ITICN PIE EQUIVALENT TO LTA SAVEAREA AIDRESS NOT User Action: Reissue valid address. the command with a !!~lana!ion: The current saveaIea address in the PIB (Partition Informaticn Block) is not the same as the save area in the LTA (Logical Transient Area). 096E FILE 'fn ft' DATA BLOCK COUNT INCORRECT ~!]lsBatioB: .§.Ist2 Acti2!!: RC = 100 Execution of the command is terminated. The number of data blocks read from tape (for file 'fn ftl) does not match the number in the model file status tatle written on the tape when the file was dumped. User Action: Reissue the ccmmand; if the problem--persists, call IEM for software sUJ;:port. ~l§!~.!!l 092E STXIT SAVEAREA ADDEESS INVALID lAE!~tion: The specified savearea address in a STXIT operation is not within the address range of the virtual machine • ActiQg: RC = 100 Execution of the command is terminated. The system status remains the same. .§.Ist~!!!. ]§er Acti~B: Verify the save and reissue the command. area address Actio.!!: Execution of the command is terminated. The portion of the file Ifn ft' loaded exists on disk as tape CMSUT1. User Action: To ensure that the file is properly-loaded, reposition the tape to the beginning of the file and reiSSUe the TAPE lCAD command. 096S UNSUPPORTED FUNCTION IN A LIeCS BOUTINE ~ZElanation: A Logical IOCS routine called to perform a function which routine was not generated to perform. was the THAN lctio,!!: RC = 100 Execution of the ccmmand is terminated. The system status remains the same. Explanation: The specified MVCOM macro is attempting to alter a position other than the allowed positions 12 to 23 of the communications region. User Action: Verify that all logical functions-to te performed are supported by the Logical IOCS routine linked with your program. ~~!~~ 093E MVCOM MACRO ATTEMPT TO POSITION 12-23 OF COMREG ALlER O!HER Acti2!!: RC = 100 Execution of the command is terminated. The system status remains the same. ~yst~.!!l 097E NO 'SYSRES' VOLUME ACTIVE ~~ElsBs!!Q'!!: User Action: Correct the specification of the-MVCOM-macro and retry. No system residence disk (SYSRES) is active; therefore, no procedure library or relocatable library is active. ActiQB: RC = 36 Execution of the command is terminated. The system status remains the same. ~Y§!~.!!l 094E FROM ADDRESS ON MVCOM MACRC INVALID ~ZE1~Bati2!!: The address specified in the MVCOM macro is not within the range of the virtual machine. Act!Qg: RC = 100 Execution of the command is teIminated. The system status remains the same. User Action: Use the "SET DOS ON mode" and commana-~ activate a SYSRES disk, reissue the command. ~yst.m!! ]§~~ Acti2!!: Correct and retry. the address specified 098E NO {PHASEIPROCEDURE} NAME SPECIFIED ~~El~.!!s!ioB: The command reguires the specification of a phase name or J;:rocedure name • .2lli.m!! Actio,!!: RC = 24 Execution of the command is terminated. !he system status remains the same. Conversational Monitor System (CMS) Messages 131 DMS User Action: Reenter the command supplying a-phase-naie or procedure name. Action: RC = 40 Execution of· the cem1Dand is terminated. The system status remains ,the same. .2.1§!~ 098S CMS OS SIMULATION NOT AVAILAELE ]~§I An OS SVC was issued and a CMS saved segment is not available. OS simulation text is not loaded in free storage. Message DMSINSC99~ or DMSSET099W was previously issued. gz~lanatiQll: !ct~Qn: The system is terminated abnormally, with an abendcode of X'OF9'. A£YQll:Use the SET DOS command to activate or deactivate. the CMS/DOS environment and re.issue th~ command. 099W GENERATION VM/SP PARAMETERS INCOMPATIBLE WITH ~~§!§~ User Action: -,:- Access a disk containing the proper text for OS simulatien and issue the command SET SYSNAME CMSSEG name, where "name" is invalid (in order to get the os simulation text loaded into free storage), or 2. Issue the command SET SYSNAME CMSSEG name, with a valid name (in erder to be able to use the os simulation text in that saved segment). ~l~natio.!!: The parameters specified on the HOST macro in the stage one input stream for an ~CP or PEP control program were not egual to the values I:eguired by VM/SP. The ccntrol program may not operate correctly if used by VMI S,P. (This message does not prohibit saving or loading the centrol program. It may not indicate an error if theVM/SP generation and lcad procedures are qsed for a 3704/3705 control program intended for qse by a virtual machine sJstem other than ~M/SP.) .§"yst!i!~ A£.!:iQ!!: For Processing continues. DMSNCP, RC 99. 098W CMS OS SIMULATION NOT AVAILABLE ]z~l~nati2n: DMSINS098W is displayed if, during CMS initialization, it is determined that a CMS saved segment is net available or cannot be loaded, and the OS simulation text could not be loaded into free storage. tMSSET098W is displayed if, after it was determined that the CMS saved segment was not available, an attempt to load the OS simulation text was unsuccessful. tMSSET098W is preceded by message DMSSET100W. !£~~Q~: If the message is DMSSET098W, RC 4. If the message is DMSINS098W, no return code is passed and initialization proceeds nermally. Any issuance of an OS SVC that follows either of these messages causes the message DMSITS098S to be displayed and the system to terminate abnormally. 100E NO EATCH PROCESSOR AVAILABLE ]nlanatio.!!:The CMSBATCH . module could not find the DMSBTP TEXT S2 file (Batch processor) on any system disk. .2.1§.!:~ ~io!!: At this point, the operator has a normal CMS interactive machine, not a batch machine. User Action: Contact personneL- your system support ~~~~§~ US§I !£tiQll: Access a disk containing the proper text for OS simulation or, using the SET command, specify a valid CMS saved segment. 099E CMS/DOS ENVIRONMENT {NOT} AC'IIVE EX]la~~tion: If the message is CMS/DOS ENVIRONMENT NOT ACTIVE, the CMS/DOS environment must be active in order for the command to execute. If the message is CMS/Des ENVIRONMENT ACTIVE, the CMS/DOS environmEnt must not be active in order for the command to execute. If the message is from DMSOPI I/C error reading text, an I/O error has cccurred reading from a library and the CCW will be displayed. 132 IBM VM/SP System Messages and Codes !iQ.Y.!:i!!g: This message is displayed Eatch Facility console at initialization tim~~ at the Batch 100W {CMSSEG} SYSTEM N'AME • name" NOT AVAILABLE SHARED {SSTA7IYSTATJ NOT AVAILABLE ]~.El.2l!atill: (fqr "CMSSEG SYSTEM NAME 'name' NOT AVAILABLE") The CMS saved segment name indicated in the message is nota;vailable.. This can occur if the size of the virtual machine is defined past t:hestart of the saved segment. This message can. also occur if an error occurred when a L01DSY5 DIAGNOSE was issued for the i~~icatEd segment name. ~!.Elg~lli,B:(for "SHAltEl) {SS7AT 11STAT} NOT AVAILA'BLEtt) The S-disk orY-dis'k has been modified since theCMS 'sY$tem was saved. .2lli~.!!! Acti.Q~: ,(for 'IIC!!SSEG SYSTEM NAME • name' NOT AVAILA·ELE") ,,' F'or tMSSE't i . RC =4. ForD:MSINS, no return code is issue'd~ The command is not executed. The syst~~ status remains the same. DMS ~ystem. ActiQ.!!: (for "SHARED {SSTA'IIYSTAT} NOT AVAILABLE") For SSTAT, the S5'!!T is l:uilt in user storage. For ,YSTAT, th~ Y-disk is accessed using the cas lCCESS c~~mand. .!I.§~~ 102S 'ICO MANY FILEIDS ~zE12.!!g.!io.!!: Too many input fileids were specified. RC = 88 Execution of the command is terminated. 'Ihe system status remains the same. ~~.§te.!!! ]£j:!Q~: Actio~: (for "CMSSEG SYSTEM NAME 'name' NOT AVAILABLE") For DMSSET, reissue the command, specifying a valid name. Fot DMSINS, define your virtual storage under the start of the CMSSEG. For both DMSSE! and DMSINS, if the ~roblem persists, contact your system support personnel. ]§§~ !£.!iQ'!!: To correct this situation, use two COPYFILE commands, specifying the APPEND option with the second one. 103S NUMBER OF SPECS EXCEEDS MAX 20 .!I.§er Action: (for "SHARED {SSTA'IIYS'IAT} NOT AVAILABLE") Call your syste~ suppo~t'personnel. ~~E!g~.!io~: More than 20 specifications were entered. ActiQB: RC = 88 Execution of the command is terminated. The system status remains the same. 101E EA'!CH NOT LOADED ~l§tem 1. The CMSBATCH command was issued after the first carriage return following IPL, or 2. The CMSBATCH module encountered errors trying to load the Df!SB'IP 'lEX'! S2 file (Eatch p,rocessor). See the LOAD comman4 for possihle errors J or User Action: Use more than one COPYFILE ccmmand;-Possibly specifying OVLY after the first one. 104S ERROR DISK 'nn' READING FILE 'fn ft fm' FEeM !~.B12.!!2.!io.!!: 3. The CMSBATCH modu,le could not locate the DMS13'rPAB entry point in DMSBTP while searching the leader tatles. At this poirit DMSBTP has already been loaded. An unrecoverable error occurred while reading the file from disk. nn indicates the nature of the errer; it may be one of the follewing: ~.§.!~'!!! !£j:!.Q~:' At this peint, the operator has a normar eMS interactive machine, not a tatch machine. ' 3 Us~ Acti.Q'!!: If the explanation is (1) follow start~upprocedure (starting with IPL). If it is (2) or ,(3), contact your system support personnel. llQuting: This message is displayed Batch Fac~lity console at initialization time. at the Batch 5 7 8 101S 'SPECS' TEMP STRING SiORAGE EXHAUS'IED AT ]Z.Bl.9~ill.Ql!: A specification list was so long that the storage' area reserved for storing specif~cation strings was exhausted. 9 11 ~.Y.§tem ,acti.2!pRC = a8 Execution of thecom~and dsterminated. The system status remairis thesa~e. 12 .!I.§§~ Acti,Q.!!! copy' the file twice, possibly using the OVLY optiori a second time, so that less string storage is needed each time. 13 14 15 25 Mean:i:nSl The specified file was not found. The buffer area is not within user storage limits. A permanent disk read error occurred. This may occur if you link to and access another user's disk, and try to read a file that was refiled 1:y its owner after you issued the ACCESS command. Reissue the ACCESS command and try to read the file again. The numl:er of records is less than zero or more than 32768. The fixed/variable flag in the file status table entry is not F or V. The given storage area was smaller than the actual size of the records read. ('Ihis error is valid if reading the first portion of a large record into a small tuffer. It does not cause the function to terminate.) The file is open for writing and must be closed before it can 1:e read. Only one record can be read for a variable-length file. In this case, the number of records is greate~ than 1. An unexpected end of file occurred (the record number specified exceeds the number of records in the file). A variable-length file has an invalid displacement in the active file table. An invalid character was detected in the filename. An invalid character was detected in the filetype. Insufficient virtual storage is Conversational Monitor System (CMS) Messages 133 DMS 26 27 available. Reguested item number is negative, or item number plus number of items exceeds file system capacity. An attempt was made to u~date a variable-length item with one of a different length. for the file. If a permanent disk read error occurs (code 3), i t may be the result of the user having detached a virtual disk without releasing it. CMS, not realizing that the disk is no longer part of the virtual machine, assumes that the disk is still active and encounters an error when it tries to read or write the file. ~st~~ ActiQn: RC = 100 or RC=1nn ('nn' described above) Execution halts. The system remains in the same status as before the command was entered. For DMSEDI, the edit session is terminated. If the error occurred during a RENUM operation, the workfile is erased and the file being edited remains unchanged. For DMSDSL, the condition file is unpredictable. For DMSGLO, no global were created. of the variable tOSLIE tatle(s) If a permanent disk read error occurs (Ccde 3), i t may be the result of the user having detached a virtual disk without releasing it. CMS, not realizing that the disk is no lenger part of the virtual machine, assumes that the disk is still active and encounters an error when it tries to read or write the file. 105E NO JOB CARD PROVIDED El£!gBg!iQn: The first record of job was not a /JOB card. the user ~~~ For DMSLBM, the condition file is unpredictable. of the MACLIB ActiQB: The batch facility has flushed the user job and continued with the next user job. Ag!ioB: Resubmit the job to the batch facility with the first record of the job in batch facility /JOB format. For DMSGLB, that litrary is not glcbaled but the operation continues for any other libraries named in the command. ]§~~ For DMSXGT, if the error cccurred during a GET or RERUN operation, the subcommand is terminated and the editing session continues. jQY!j~: I For DMSXIN, the execution of the command or subcommand is terminated. If multiple files were being edited, the editing session continues for those files. For the TAPE command, if the DEN, ~RTCH, 7TRACK, or 9TRACK 0Ftions were specified, the modeset byte has been set fer the specified device (TAPi, where: i = 1, 2, 3, 4) or TAP1. Some records may have been written on tape. This message is displayed at the Batch Facility console during user job execution. 105S ERROR DISK 7 8 9 10 For DMSDGL, verify DeSLIE integrity the DOSLIB MAP command. with For DMSGLB, RDBUF has returned~a RC other than 0, 1, or 8. RC=1 indicates it is an OS/DOS DISK and RC=8 occurs if the lRECL is greater than 80. Either of these conditions is acceptable. For DMSLBM, verify MACLIB integrity the MACLIB MAP command. with 11 12 13 14 15 16 17 For DMSLIO and DMSMCD, reissue the entire LOAD/INCLUDE sequence after checking the error conditions. 18 19 For error code '09', issue an FSCLOSE macro 134 IBM VM/SP System Messages and Codes FILE 'fn ft {fm}' ON E1B!gBg!ion: An unrecoverable error occurred while writing on disk. BB indicates the nature of the error; it may be one of the following: Q§~~ Agtion: If you can determine the problem from the "Explanation" and remedy the condition, reissue the ccmmand. If not, retry the command and if the Froblem persists, call your system support personnel. 'nn' WRITING Megning The virtual storage address is O. The first character mode is invalid. The second character mode is invalid. The number of records in the file is toa large; it cannot exceed 65,533. An attempt has been made to skip over an unwritten variable-length item. The number of bjtes was not specified. The file is already active for reading. The maximum number of CMS files (3400) has been reached. The fixed/variable flag is not F or V. The disk is not a CMS read/write disk. The disk is full (recoverable error). The number of bytes to be written is not integrally divisible by the number of records to be written. The length of this record is not the same as that of the previous record. The fixed/variable flag is not the same as that of the previous record. A variable-length record is greater than 65K bytes. The number of records is greater than 1 for variable-length file. The maximum number of data blocks Fer file (16060) has been reached. Des 20 21 22 25 26 27 An invalid character has been detected in filename. An invalid character has been detected in filetype. Virtual storage capacity has been exceeded. Insufficient virtual is storage available. Requested item numteI is negative, o:r item number plus numbe:r of items exceeds file system ca~acity. An attempt was made to u~date a variable length item with cne of a different length. Acti2!!: RC = 100 Execution of the command terminates. system status remains the same. ~Ist.!l!!!! verify DOSLIB integrity. For DMSLBM, use the MACIIB MAP fUnction to verify MACLIB integrity. For DMSLIC, reissue the LOAD/INCLUDE sequence from the beginning, after checking the above error conditions. I I I I For DMSXCP, specify a smaller partition with the SET DOSPART command, or use the CP define storage command for a larger machine and IPL CMS. 106E JCB CARD FORMAT INVALID The ~1!121g!!gti2!!: 1. The batch facility detected a missing or invalid userid or missing account number on the user /JOB card, or 2. The userid (if provided) does exist in the VM/SP directory, or 3. A user /JOB card exit routine (BATEXIT2) returned a ncnzerc :retu:rn code in general register 15. For DMSDSK, the reade:r file is saved. The status of the output file is unpredictable. For DMSEDI, the edit session te:rminates. The status of the file is as it was tefore the edit session or at the execution of the last SAVE subcommand or automatic save. The RENUM workfile is erased. A wo:rkfile, EDIT CMSUT1, may have been creatEd en the input disk. not For DMSDSL, the condition file is unpredictable. of the tOSLIE Syst~ ActiQ!!: The batch facility flushes the user job and continues with the nExt user job. For DMSLBM, the condition file is unpredictable. of the MACLIB y§~£ For DMSLBT, DMSLST, DMSMCD, tMSSET, tMSTPD, and DMSUPD, the status of the output file is unpredictable. For DMSRDC, the reader is closed with HOLD status to preserve the file. A£!ion: Resubmit the job to the batch facility with a valid userid and an account number in the batch facility /JOB card. ~QY!i!!g: This message is displayed at the tatch facility console during user job execution. a For DMSTPE, if the DEN, TRTCH, 7TRACK, o:r 9TRACK options were specified, the modeset byte has been set for the specified device (TAPi, where: i = 1, 2, 3, 4) or TAP1. The status of the output file is unpredictable. The tape may not be in the same position as before the command was entered. For DMSXCP, the EXCP request fails with the return code nne Cheok the att:ributes of the file specified in the DTF and DIBI. For DMSXFD, if the error oocur:red du:ring a FILE or SAVE, a temporary work file, XEDTEMP CMSUT1, may have teen created on the input disk. For DMSXPT, if the error occur:red during a PUT (m orBENUM operation, the sutcommand is terminated and the editing session continues. 106S NUMBER OF MEMBER NAMES FILE 'fn ft' NOT ADDED ~1!121g!!g!ioB: dictionary 1000. EXCEEDS MAX 'nnnn'. The number of entries in the has exceeded the maximum of Action: RC = 88 The system tries to write the dictionary up to and including the previous text deck; then it te:rminates execution of the command. ~..Y§!~ Either delete unnecessary the library and retry, or start another library. User Action: iembers-~rom 107E CP/CMS COMMAND ALLOWED 'command, {device}' NOT A£!io~: If you can determine the problem from th~ "Explanation" above and remedy the condition, reissue the command. If not, reissue the command and if the problem persists, call your system support personnel. !!£lgnati£D: The named CP or CMS command is not allowed under the CMS batch facility. If it is a CP command, the device is also displayed. If it is a CP LINK command, more than ten LINK commands have been issued without compensating DETACH commands or a possible error has occurred in the LINK command itself. For DMSDSL, use the Syst.!l!~ ]§~ DOSLIB MAP function to Conversational A£!ion: CMS continues ~onitor with thE next System (CMS) Messages 135 OMS 109B (CPUIPBINTIRIPUNCH) command in the user job. !£!ign: Do not resubmit this eommand with any batch job. If this was a tINK command reject, check to be sure the LINK command is correct or net more than t~n LINK commands have been issued without compensating DETACH commands. ReissUE the LINK command after detaching anether disk. Q§~ RQuting: This message is displayed at the batch facility console during user job execution. It will appear on the s~ooled console output sheet. LIMI~ EXCEEDED iJRlII!!ign: A user job exceeded the naled limit during execution. The limit was determined either by the user job through a /SET control card or by default to the installation settings. ~ jction: The user job is flUshed and the next batch job is started. Action: If the results are unexpected, debug the job before resubmitting it to l::atch. ]~, 109S VIRTUAL STORAGE CAPACITt EXCEEDED 1075 DISK 'mode {(cuu)}' IS PULL There is not enough s~ace on the specified disk to write the file. EJBl4D~2B: !£ii2B: RC = 100 Execution of the command is terminated. Some records of the cutFut file may have been written out. ~I§!gm Action: Erase some files from the disk and reissue the command. Y§~ 108E JSET CARD PORMAT INVALID !lRlanation: The batch facility detected invalid information on user's JSET card. PoSsible errors include: • No tlank delimiters betWEen entries • Invalid keywords • Noninteger values for settings • Values for settings installation limits. greater than svst~! !£!i2B: The user jot is flushed and the next batch job is started. !£!iQB: Correct the JSET card and reSUbmit the job to the Batch Facility~ IJ~IDA!igA: There is no more s~ace available in your virtual machine to successfully complete execution of the command. Subseguent execution of certain CMS commands may cause the same problem. lor nMSACC, insUfficient free storage remains to access the specified disk. For D!SAMS, Access Method Services vas unable to obtain free storage for the terminal buffer to read the tape aanames. ror DMSBWR, a write buffer operation attempted to write beyond the limits of the virtual machine's storagE. ror nMSFCH, either the Fhase being fetched would exceed FRB~LOWE, or in the case of ietching a $$B transient phase, the transient routine would exceed the end o~ the transient area. lor DMSHLP, not enough storage was available to either load the DMSHID communication module or acquire tuffer space to format the HELP text file. For DMS1!M, not enough virtual storage was available to contain the MACLIB dictionary. Q§~~ This message is displayed at the batch facility console during User job execution. It appears on the sFeoled console output sheet. ~2B!ing: 108S MORE THAN 8 LIBRARIES SPECIFIED l1f!2natioB: Only eight MActIBs (macre libraries) or TITLIBs (text litraries) may be specified with a GLOEAl command. §,I§!n Acti.Q1l: RC = e 8. Execution of the command is terminated. The old MACIIB or T%TLIB list is cleared. Regenerate the MACtlBs or TXTLIBs to include members from other MACtlBs or TITLIBs, therety reducing the Dumber of libraries reguired for this terminal session. Q§~ 136 !cti~: IBM VM/SP System Messages and Code$ lor DMSLXO, the loading of text files has caused either the transient area or user area limit to be exceeded~ iext file si2es are determined by the length fieldso£ ISD statements. An ihcorrect value in the length field of·an ESn statement may Cause this condition~ por DMSSOP, the storage to be used for saving the original DCa is not 8vai1a1::1e. For DBSPRS, either the initial reguest for a large block of storage failed, or storage was exhausted during sutalloeation of the block while processing normally. .D!SBWE passes a return code of 22 to the program that called it, which then passes a return code of 104~ DMSSM6 is terminated abnormally with abend code 1 1 804' or X'SOA'. DBSVIP abends with CMS abend code X' 177'. All other modules that issue this message pass a return code of 104; execution of the command is ~1!!iIAS!!gB: DMS terminated, and the same. the system status remains For DMSACC, the disk is not accessed. Any disk already accessed at the sIecified point in the search order is released, but not detached. lor DMSOVR, was on. SVCTRACE is turned off if it For DMSLBM, if additions were being made to the MACtIB (GEN, ADD, or REP functions), it contains all successful additions made before storage was exceeded. For DMSSOP, terminated. opening of the file is address than the one you are using. If the saved system CftSL is available, IEL it, if bot, contact your system support perscnnel. \101 COBBICT FOBM IS: (SEGNAftE) {DOSGENICMSXGEN} LOCATION IJRlI~isD: An invalid form of the tOSGEN or eftSXG!N command was specified. lli.!O .Aill.2.!!: :R C = 2" Execution of the command is terminated. system status remains the same. ~he gser J&li£D: Correct and reiSSUE the command. 'segname' is oEtional; if you do not specify it, it defaults to CMSDOS for DOSGSN and to CMSS!G for CMSXGEN. Y§!~ Action: You can use the CP t!FlNl command to increase the size of the virtual machine, or issue the C~S cemmand RELEASE for any disk no lenger needed, to free some of the virtual machine storage. IPL CMS again and reenter the command. Alternatively, you can do the fellowing: For DMSARN t DMSSMN, and DMSTPD, reduce the size of the program and retry. For DMSDLB, clear old definitiens that ate no longer needed, and retry_ For DMSLBM, issue the MACLIE MAP com.a~d t~ determine the contents of MACIIB. tefine additional storage with a CP D!FlNi command. Continue processing with the remaining additions. For DMSLIO, redefine loading loc~tion. (origin) or redefine the virtual storage size using the CP command DEFINE. ReiSSUE the entire LOAD/INCLUDE seguence. 109~ 1'05 EBROB BBA~lNG 'TAPn {(cuu)}, JlB1AAis!9~: A permanent I/O error occurred while reading the specified tape, or the tape is not attached. jstis~: RC = 100 Bxecution of the command is terminated. For the TAPE command, if the DEN, ~R~CH, 7~RAC~, or 9TRACK options were specified, the modeset byte has teen set for the specified device (TAPi, where: i = 1, 2, 3, ~) or TAP1. The tape may not te in the same position as before the comm~nd was entered .. §I!!iJ ]5!1 Action: If the tape is attached, make sure that it is the correct tape: rewind the tape via the TAPE REi command, position th~ tape, and retry. If the error persists, check the format of the tape for parity errors, missing tape marks, etc. For the TAPEMAC command, if the problem persists, use the OS utility IEHftOVE to create the PDS ag~in on another tapE. If you ran out of storage while trying to acguire a large GET MAIN area, and your virtual machine size is atove the start of I 111E {DOSGEN I CMSXGEN} FAILEt DUE TO LOAD ERROES the CMS nucleus, you shculd IPI a eMS system gen~rated at a bigher virtual IJ~!jn!li2n: Errors occurred when trying to address than the one you are using. If the load (using the Loader) CMS text decks into saved system CMSL is availatle, IPL it, if the discontiguous saved segment. not, contact your system su~~ort ~ersonnel. §1!1t!U! A2!i2,Q BC = 36 VIRTUAL STORAGE CAPACITY EXCEEDED Execution of the command is terminated. ~he system status remains the same. llE!!nati2n: There is insufficient virtual storage available for file management .!Un A£lliJ!: Print or display the file on control blocks. the A-disk with filename and filetype 'LOAD MAP't Which contains diagnostic messages. In sale cases, Loader messages may precede ~!! !£!i£~: The virtual machine is placed in a disabled wait state and thQ this message. !f this occurs, refer to the disk is not updated. Loader message and fol1ew the User action given. Q§§~ !Q!!QB: Issue the CP cemmand DlPINE to increase the size of the virtual machine, IPL eMS again and reenter the command. 111S EaBOR WRITING 'TAPn (cuu) , If you ran out of storage while trying to acguire a large ~E~MAIN area, and tour Virtual machine size is above the start of the CMS nUCleus, you should IPl a eftS system generated at a higher virtual JJR1!i!S!e~: A permanent I/O error occurred when writing the specified tape. §~J ~i2A: 1f the DEN, RC = 100 TRTCH, 7TRACK, or Conversational Monitor System (CMS) Messages 9TIUC~ 137 DMS options were specified, the medeset byte has been set for the specified device (TAPi, where: i = 1, 2, 3, 4) or ~AP1. The tape may not be in the same ~esition as before the command was entered. User Action: Reissue the ccmmand. If the error persists, contact your system su~port personnel. 112S 'mode (cuu)' DEVICE ERROR An error was encountered in trying to access the disk, either because it is an unsupported device, or because an I/O error occurred while reading in the master file directory from the device. ]ZE!!~: ActiQB: RC = 100. Execution of the command is terminated. The system status remains the same unless another disk was replaced bj this access, as indicated by message DMSACC724I. ~y§!~ !£!i~B: RC = 40 or -0005 The command is not executed. User Action: Use the CMS command SET to set Des-onoroff, and reissue the cOIl.ano. 114S 'cuu' IS AN UNSUPPOBTEt DEVICE, OB REQUESTED BLKSIZE IS NOT SUPPORTED fOa IHS DEVICE gZR1~ns!io~: VM/SP does not support either the attached device or the requested block size. ~y§!2 !£lliB: RC = 88 Execution of the command is terminatEd. The system status remains the same. ~~§!~m User Action: If this is the first time that you-are-llsIng this CMS disk, use the FORMA~ command to format it. Reissue the command. If the problem persists, contact your system support personnel. 113S {modeIDEVICEIDISKIPRINTERIPUNCHIRIAtIRITAPnl TAPINI TAPOUT} (cuu) NO~ A~'IACBEt A!ElgnatiQB: The specified device is not attached to the virtual machine. If the message is issued for a tape, it also may mean that the tape bas net teen mcunted or the device is not ready. ActiQB: RC = 100 Execution of the command is terminated. The system status remains the same unless another disk was re~laced by this access, as indicated by message DMSACC124I. ~ystem Ac!i2B: If the specified device is a disk, issue the CP command LINK to attach the disk to the virtual machine, or ask the system operator to attach the disk tc your virtual machine. ]§~~ If the specified device is a printer, punch, or reader, use the CP comman~ tEFINE to attach it to your virtual machine. If the specified deviCE is a tape drive, ask the system operator to attach or mount the tape and ready the device. Then reissue the command. 114E 'PROGRAM' NOT {NOT} ACTIVE] ~OADED; [eMS/tOS ENVIRCNMENT Either the CMS/DOS environment is active and you are trying to load a program that uses OSmacrcs, or the CMS/DOS environment is not active and you are trying to load a program that uses DOS macros. Neither of these situations is allowed. ExR!g~!i2B: 138 IBM VM/SP system MessagES and Codes ]~~ Ac!i~: Attach a device that is supported by VM/SP, or issue the ccmmand with a valid tlock size for the deviCE. 115E PHASE LOAD FOINT LESS THAN 'address' The phase load point is less than the beginning of the user area. j~l~B: Syste! !£!i2B: RC = 40 Execution of the command is terminated. ~he system remains in the same status as tefore the routine was entered. User Action: Ensure that the phase load point -rS--greater than or equal to the teginning of the user area by altering linkage-editor control statements. 115S {CONVERSION, PI 9} -TRACK I {SOO I 6250} BPII TRANSLATIONIDOAL-DENSITY} FEATURE NOT SUPPORTED ON DEVICE 'cuu' EZRlgBgtiQ11= The user has specified a tape mode setting that requires a f~ature not supported by the attached real deviCE. ~l§!~! = !£!1211: RC 88 The system remains unchanged; the device has not been repdsiticned~ tap~ Q~~I A£!ioB: Reissue the command using mcde options (nTRACK, DEN, 1R~CH) appropriate for the attached devices; or attach a device with the a~propriate features. 116S LCADEB TABLE OVERFLOW lillanatio!!: There are too many entry ... point or control-section names in the loader table built during loading_ .§.l§!~ !ctio!!:RC =104 Loading is terminated. l!§~! !£.ti.2!!: IpL CMS again, redefine the number of leader tables with the Sl~ command, and issue the LOAD/INCLUDE sequence (for DKSLIO) or the LCADKOD command (for DMSMOD). DMS 117S ERROR WRITING TO DISFLAI TERMINAl !Z~J~gtiQ~: An I/O error occurred when a DIAGNOSE command was issued to write to a display terminal during an EDIT or System Product Editor session. macro or if an I/O error is encountered by an OS CHECK, GET, or POT macro and a SINADAF routine is not specified by the user. For an XEDIT session, the terminal is set to typewriter mode, and the editing session continues. For DMSSVT, this message is built by the simulation routine for the SYNALAF macro; it is issued by a user SYNAD routine. If the message is printed by an OS program Froduct SYNAD routine, the SYNAD routine usually places a message number of its own in front of the message number listed above and appends some information of its own to the end of the message. Q~~ Ag!i~: Retry the EDIT session. If the problem persists, contact your system support personnel. .§l'§!~l!! A£!i2!!: For the System Product Editor, the subcommand SET TERMINAl rISPlAI may be issued to return the editor to display mode. If the problem persists, contact your support personnel. For DMSSVT, execute. Action: RC = 100 The EDIT session is terminated. The virtual machine is placed in CMS mode. ~te.!!! 118S ERROR PUNCHING FILE {'fn ft fm'} ~Z]Jg~g!!on: An input/outtut error occurred while punching the file • !£tion: RC = 100 Some of the file may haVE been Funched. The file being read is closed and an attempt is made to close the Funch before terminating the command. For DMSSCT and DMSSBS, CMS is terminated abnormally with an abend code of 1. the program continues For DMSFCH, RC 100 and execution command is terminated. to of the User Action: Use the error code to determine-the correct message and possible cause of the error. .§1§!~'!!! User Action: Reissue the ccmmand. problem--persists, contact your support personnel. 119S UNSUPPORTED {MACRO I SVC} FORM OF Code Meaning 254- BSAM, BPAM, or BPAM-CHECK was called with an unposted ECE specified. If the system l1~gning {'macro' I 'parm'} EX]lg~!iQn: An unsuPtorted or invalid form of the macro or SVC listed in the message has been executed by a user Frogram. 3 5 .2.1st.§1!! Ag!ion: CMS is terminated abnormally with an abend code of X'QOO'. 7 8 Q§~ Ac!iog: Check your program for an invalid or unsupported form of the macro listed in the message. 9 120S {INIOUT}PUT ERROR COLE 'nn' ON 'ddname' 11 ]z]lgnati~: The indicated error code was returned from an OS READ, WRIlE, GET, or PUT macro. The error code in the message is sUtFlied only if the error was an INPU! or OUTPUT error, not if it was a FIND, POINT, ESP, or some other type of operaticn error. Error codes differ for the various types of devices. Error code meanings are listed below. 12 13 25 26 80 For DMSSCr, CMS issues this message I/O error is encountered by an OS if an CLOSE 255 The file was not found. The virtual storage area was not within the limits of the virtual machine. A permanent disk error occurred. The number of items was zero. The fixed/variable flag in FST entry was not F or V. The given storage area was smaller than the actual size of the item read. (Recoverable error; the number of bytes corresponding to the size cf the buffer have been read.) The file is open for writing; it must be closed before it can be read. The number of items is greater than 1, for a variable-length file. An unexpected end of file occurred (the item number specified exceeds the number of items in the file). A variable-length file has an invalid displacement in the active file table. Insufficient virtual storage is available. Reguested item number is negative, or item number plus number of items exceeds file system capacity. An I/O error occurred while reading an OS data set or DOS file. BDAM or ESAM (CBEATE)- either: Conversational Monitor System (CMS) Messages 139 DMS 1. A specification error occurred, or 2. An I/O error occurred while reading or writing KEYS, or 3. The XTENT option was not specified in the FILEDEF command, or the XTENT was too small. BPAM - An I/O error occurred while reading in cr writing cut the directory of a MAClIB file. specified in the FILED!F command, or the XTENT was too small. BPAM - An I/O error occurred while reading in or writing out the directory of a MACLIB file. Code --212 Note: All errors except 8 (above) cause execution of the command to terminate. Error 8 is valid if reading the first portion of a large reccrd into a small buffer. Code !!~anigg --,- The filename or filetype was not specified, or is invalid. 2 The virtual storage address is 2ero. 4 The first character mode was invalid. 5 The second character mode was,invalid. 6 The number of records in the file is too large; it cannot exceed 65,533. 7 An attempt was made to skip ever an unwritten variable-length item. 8 The number of bytes was not specified. 9 The file was already active for reading. 10 The maximum number of CMS files (3500) was reached. 11 The fixed/variable flag was net F or V. 12 13 14 15 16 17 18 19 20 21 22 25 26 27 255 140 The mode is S (system) or other read-only disk. The disk is full. The number of bytes to be written is not integrally divisible by the number of records to be written. The length of this item is not the same as the previous item. The fixed/variable flag is not the same as that of the previous record. A variable-length item is greater than 65K bytes. The number of items is greater than 1 for variable-length file. The maximum number of data blecks per file (16060) was reached. An invalid character was detected in the filename. An invalid character was detected in the filetype. Virtual storage capacity has been exceeded. Insufficient virtual storage is available. Reguested item number is negative, or item number plus number of items exceeds file system capacity. An attempt was made te update a variable length item with one of a different length. BDAM or BSAM (CBEATE) - either: 1. A specification error occurred, or 2. An I/O error occurred while reading or writing KEYS, or 3. The XTENT option was not IBM VM/SP System Messages and Codes !1~gning Invalid code - no read was issued. A null line or end-of-file condition was encountered. fQlf.§Ql!1i OUTP.!!l None. !!~gl!il!g 3 4 5 6 7 8 12 An invalid function or option list was encountered. A permanent I/O errer occurred. An invalid device identification was specified. The tape was not attached. The tape is file protected. A serious tape error occurred. Incorrect length error. An end-of-file or end-of-tape condition was encountered. Code MeaniB.9 --1- The buffer size is too large. 2 Channel 12 was sensed (virtual 3211 onl y) • 3 Channel 9 was sensed (virtual 3211 only) • 5 An unknown error occurred. device is not attached, or 100 The intervention is reguired. !1~sH!i1!.9 8 12 100 The file was not read. An unkncwn error occurred. The device is not operational. The count was net egual te the reguested count. The given storage area was smaller than the actual size of the item read. (Becoverable error; the number of bytes corresponding to the size cf the buffer have been read.) End of file was reached. The device is not attached. MegniB.9 An unrecoverable unit check occurred. An unknown error occurred. The device is not operational. The device is not attached. DMS 121S UNSUPPORTED SVC addr svc (HEX xx) CAllED FROM EX]lanatig~: The caller issued an SVC, specifying a number that was not recognized by the CMS or CMS/DOS SVC handler. The CMS SVC handler following SVC numbers: • • recognizes the 123S ERROR 'nne fm' {PRINTINGIPUNCBING} FILE 'fn ft j~£l~ation: An I/O error was encountered while attempting to print or punch a record. Refer to message DMSxxx120S for an explanation of error codes. A£!ioB: RC = 100 The output device is closed and execution of the command is terminated. i1S!~m SVC 202 (X'CA') and SVC 203 (X'CB') are always recognized by the CMS SVC handler, since these SVCs are used to specify CMS system functions and commands. A program may specify an SVC handling routine by means of the HNDSVC function. Until cleared, these SVC numters are recognized by the SVC handler. User Action: Use the error code to determIne-possible cause of error. Reissue the command, and if the error perSists, contact your system suppcrt personnel. 124S ERROR READING CARD FILE gl£!§~~!ioB: • • Certain SVC numbers are supported by the OS macro simulation rcutines. ~here are two types of these simulation routines. The SVC numbers sUFPorted by the storage-resident CMS nucleus are always recognized by the SVC handler. ~hose supported by the disk-resident transient library are recognized by the SVC handler only if the file DMSSVT module can be found. Certain SVC numbers are supported ty the DOS macro simulation routines. The SVC numbers supported by the shared segmentresident routine are always recognized by the SVC handler. ~fter the error message is Acti~: displayed, no further action is taken. Control returns to the routine that made the SVC. For DMSDOS, BC 100, and execution of the command terminates. .§.I.§!~ To stop execution of the HX. You can remove the specified SVC call from the caller's program, or use the CMS SVC handler function (HNDSVC) to provide your own routine to handle the specified SVC. Us~ Action: program~~ype A permanent input/output error occurred when reading a specified file. System ActioB: RC = 100 Execution of the command is terminated. ~he reader is closed with the HOLD option to attempt to preserve the file. Y.§§f !ctiOB: Reissue the command. If the error persists, contact your installation support personnel. 125S PERMANENT UNIT CHECK ON DISK 'mode (cuu) , Explanation: An unrecoverable occurred cn the specified disk. addr, ERROR g!£l~~!ion: A CMS SVC (202 or 203) instruction was executed, and no provision was made for an error return from the routine processing the SVC. Nonetheless, an error occurred. "nnn" is the return code, in deCimal, issued by the routine given in the message; "xxxxxx" is the same return code, in hexadecimal. error A£!i2B: RC = 100 Execution of the command is terminated. Some cylinders may have been formatted. If so, t.he number is indica ted by message DMSFOR732I. al'§!~! User Action: Contact personneL- support your system 126S ERROR {READINGIWRITING} • mode (cuu) , LABEL ~l£!anation: 122S ERROR IN CALL TO routine FRCM CODE nnn (HEX XXXXXX) I/O An unrecoverable occurred on the specified disk. ON DISK I/O error .§ll!.ru!! .A£!io~: Re = 100 Execution of the command is terminated. system status remains the same. User Action: Contact person~ your system ~he support 127S UNSUPPORTED DEVICE FOR ddname .§.I§!~ !£!i2A: The system is terminated abnormally with abend code X'OF3'. gl£!~!igB: The command does not support the device specified for the given ddname. Q§~~: .§l§!~! !ctig~: If you enter DEBUG and type GO, control returns to the point to which a normal return would have been made. Register 15 contains the error code. Re = 100 Execution of the command is terminated. system status remains the same. ~he User Action: Reissue the FILEDEF command, specifying the correct device type, and Conversational Monitor System (eMS) Messages 141 DMS retry the command. If the error persists, call your system support personnel. 128S I/O ERROR ON INPUT AFTER READING RECORDS: INPUT ERROR code ON ddname nnn !zE!snatio~: The SYNAD exit was taken in response to an OPEN, GET, or CLOSE macro on the DCB for the specified ddname. The meaning of the error code can be found in the explanation of message DMSxxx120S in this manual. .§.1st.§!!l Acti.Q!l: RC = 100 Execution of the command is terminated. The system status remains the same. Us~ Acti~: Correct the condition causing the I/O error, and reissue the cemmand. User Action: Make sure that the nucleus cylInder-number is not larger than the size of the disk. If it is, perform an IEL and specify the correct cylinder number. If it is not, call your system support personnel. 132S FILE 'fn ft fm' TOC LARGE !nlanation: The specified file is large for the user's virtual machine. too .§.1.§tem !ctio~: RC = 8S Execution of the command i~ terminated. Ihe system status remains the same. ].§.§~ !£!ion: Split the file, or use the CP command DEFINE to increase the size ef the virtual machine, and reissue the command. 133S INVALID GETMAIN CR FREEMAIN SPECIFICAIION 129S I/O ERROR ON OUTPUI WRITING RECCRt NUMBER nnnn: CUTPUT ERROR code ON ddname ]~E!anatiQg: The SYNAD exit was taken in response to an OPEN, PUT, or CLCSE macro on the DCB for the specified ddname. The meaning of the error code can be found in the explanation of message DMSxxx120S in this manual. .§.1st'§!!l Ac:!:iQg: RC = 100 Execution of the command is terminated. The system status remains the same. Us.§~ !£!io~: Correct the ccndition causing the I/O error, and reissue the ccmmand. 130S BLOCKSIZE ON THAN 9 V FORMAT FILE ddname IS LESS EXEIsnatio~: Either the user passed invalid parameters or the GETMAIN or !REEMAIN chain has been destroyed. ~.1§:!:~!!l Ac!i~~: The system is terminated abnormally with abend code X'704', X'70S', X'804', X'SOA', X'90S', X'90A', X'A05', or X'AOA' • User Action: Check for FBEEMAIN-Specification program. 134S UNSUPPORTED addr. SVC 203 possible GET MAIN or errors in the user CCDE nn CALLED FROM !lEIg~!io~: SVC 203 was executed, and the halfword code following it was not recognized by the system. !!Els~tiog: The FILEDE! fer the ddname specifies a record format (RECFM) of V, but the specified blocksize (BLOCK) is less than nine. Note: A block of a variatle length (V-format) file begins with a four byte field g~v~ng the S~2e of the tlock. Furthermore, each logical record within the block begins with a four byte field specifying the size of that logical record. For that reason, a V~format file cannot have a blocksize less than nine. .§.1§te!!!. !ctiQg: RC = 8S Execution of the command is terminated. The system status remains the same. Us~~ !£tio~: Specify a blecksize of nine or greater, and retry. 135S MAXIMUM SVC DEPTH 'nnnn' WITH CALL AT addr HAS BEEN EXCEEDED j~lanatio~: SVC recursion occurs when ene SVC handling routine executes an SVC instruction which invokes another SVC handling routine Which, in turn, executes an SVC instruction. This can happen, for example, when EXEC files make nested calls to other EXEC files. error .§Y.§:!:§!!l ActioB: The system is terminated abnormally with abend code X'OF2' • .§.1st'§!!l !£j:iQg: The system centinues as if the user had responded "no" to tMSINI607R. User Acti2B: Type in the next command; this will cause abend recovery to take place. Ex~l~atiQg: 142 Use~ Action: If you enter DEBUG and type GO, control returns to the point following the SVC call. The CMS system does not allow the nesting level of SVCs to exceed 'nnnn' • 131S IPL DEVICE WRITE I/O ERROR An uncorrectatle I/O occurred while writing the nucleus. Syst~!!l ActioB: The system is terminated abnormally with abend code X'OF1'. IBM VM/SP System Messages and Codes DI!S 136S UNABLE TO LOAD 'IDCAMS' loading a disabled wait state PSi. I!R!!nation: The command has not been executed because Access Method Services could not successfully load the DOS/VS IDCAMS Access Method Services program. Us~ Actio,!!: IPL CMS again. 138S ERROR nn ERASING fn ft BEFORE LOADING TAPE £.!1!.l~.B.§j:io.B: ~1g! ActiQ~: RC = 104 Execution of the command is terminated. The system status remains the same. After determining that there was a file named 'fn ft' on the A-disk, an attempt was made to erase it before continuing the PDS load from tape. However, the erase fai~ed for the specified reason. Y§~~ A£1iQ~: Verify whether sUfficient virtual storage is availatle to run Access Method Services under CMS/VSAM. If not, define a larger virtual machine, IPI CMS again, and reissue the command. If sufficient storage was available, contact your system support personnel. Code -2428 36 136T SVC CALL FROM addr INTSVC. RE-IPL CMS IllEGALLY l1~j!Jli!.9: The disk is read-only, or the c~ticn, parameter, mode, or fileid is invalid. Erase is not allowed. The file was not found. Tbe disk is not accessed. Action: RC = 100 Execution of the command is terminated. ihe tape is positioned within the data file. ~te! BE-ENTERS ~~£!~!iQB: The CMS nucleus bas failed. An SVC instruction was executed unexpectedly by the CMS nucleus tefore interpretation of the preceding SVC call had been completed. .a.12j:~ ActiQ!!: 'l'he system is terminated by loading a disabled wait state PSi. User iode Action: Access the A-disk in and-reissue the command. 138T 'DMSKEY' CAll FROM addr SlACK, WITH MAX DEPTH 7 OVERPLOiS write KEI g.!£l~Jl~tiQJl: The DMSKEY key stack overflowed. For a comFlete description of the EMSKEY key stack, see the description of the DMSKEY macro in the !.!1L~R ~~§!~ ~~Qg~smm~~~ guide. ~~ Action: Issue the CE DUMP command to get a dump of virtual storage, save the output, and call IBM for softWare sUFPort. Then IPL CMS again. ~~~ ActiQ]: The system is terminated abnormally with abend code X'OF4'. 1375 ERROR nn ON STATE FOR 'fn ft fm' !!R!~BA!i2n: An error cccurred while attempting to determine if a 'fn ft' exists that must be erased before continuing to load the tape. nn indicates the nature cf the may be one of the following: errer; it 139S Code .!1~ing ~ An invalid character appeared fileid. 36 The disk is not accessed. RC = 100 is positioned within tbe ~APE FILE EXCEEDS 9 CMS MACLIES j~ls~Q.!!: in the Syst~ !£!iQ~: The tape file. User ActioB: If you enter DEBUG and type go, execution continues ahd the EMSKEY macro is ignored. data been created on the tape. Nine eMS MACLIEs have already and there is still morE data S'ist~! Actio!!: HC = 104 Execution of the command is terminated; the tape is positioned within the data file. !!§.§~ Actio.!!: If you can determine the problem from the "Explanation" and remedy the coneU tion, reissue the command. otherwise, reiSSUe the command and if th~ problem persists, contact your system support personnel. ..Y§~I 137T CALL TO routine FROM addr DESTROYED SYSTEM SAVE AREA. BE-IPt CMS EXBlanation: A critical system control block was found to contain invalid information upon return from a function or command. a~stem !£1iQB: The system is terminated by !£tiQ.B: If possil:le, increasE the ITEMCT value in order to create larger CMS files. If this is not fossible, it may be necessary to us~ the TAPPDS co~mandto load each member as a different £ile on the disk and then create the liAC'tIllsfrom the individual files using the M~CtIE command. 139T 'DMSKEY STACK RESIT' F~OM addr UNDI.FLOiS KEY l..!Rl~!!j!!ioJl: The DMSKEY key stack was elllFty and a program routine tried to delete one more key from it. For a complete description of the DMSK!Y key stack, see the description of the DMSKEY macro in the VM/SR .§.~stem ProgrSl!.!!!~I..!.§ Guig.§_ Conversational Monitor System (eMS) Messages 1q3 DMS ~~§!~ !£!i~n: The system is terminated abnormally with abena code X'OFS'. Q§g~ Acti~: If you enter tEBUG and type "go", execution continues and the tMSgSl macro is ignored. 1405 {'function'IFEOVDISIOVIFEOV} {MACBOIFUNCTION(~} NOT SUEPOB1ED CMS/DOS B C D E F IN CMS/DOS does not supfort the specified macros or functions. Ex~!gnA!ign: !Qtiru!: RC = 100 Execution of the command is terminated. ~l.§!g! Specification Decimal data Fixed-point overflow Fixed-point divide Decimal overflow Decimal divide Exponent overflow Exponent underflow Significance Floating-point divide 6 7 8 9 A User A£!io~: Enter DEBUG the PSW and registers at exception. mode to examine the time of thE 142S SAVED SYSTEM NAME 'name' INVALID Us~ Action: Eliminate the unsuPFortEid macros-or--functions from the use%: };rogralll and reissue the command. The name specified with the SET command was not the same as one of the labels in the SYSNAMES table; that is, it was not CMSSEG, CMSDOS, CMSAMS, or CMSVSAft. !!Blgnatig~: 140T routine BOUTINE CALLEt FBOM add%: DID tMSKEY WITH NO BESET. §l'§!~!!! !£ti2~: RC = 24 Execution of the command is terminated. ]~£!g~2n: When control returned from a command or function, the DMSK!! key stack for that command or function was not empty. For a complete descripticn of the DMSK!Y key stack, refer to the descriftion of the tMSKEY macro in the ~L~R §i§!g! Uogrammer'§ Q~. §y.§!g! !Q!ion: The system is terminated abnormally with abend code X'OF6'. Action: If you enter tEBUG and type "go", control returns from the function or command as if the key stack were empty. Q§g~ 141S {DOSGENICMSXGEN} ERRORS FAILEt DUE TC SAVESYS .Y~~ Actio.!!: Reissue specifying a valid name. j~]!s~s!iQ~: exception routine. ~ ~112~ o 2 3 4 5 §y.§te!!! Acli~: BC = 100 Execution of the command is terminated. The system status remains the same. 6 7 8 9 A !£lign: A CP error message was issued before this message. Locate the CP error message and follow the user action given. Q.§g~ jz£!gnati2~: exception location. The occurred specified at the add%: §~§!g! B C D E F IN hardware specifiea A£!i2~: The system is terminated abnormally with abena code X'Ocn', where ~ depends on the type of eXCEption: The occurred o 1 2 3 4 5 144 1~.I2~ Imprecise Operation Privileged operation Execute Protection AddreSsing IBM VM/SP System Messages and Codes hardware SPIE exit Imprecise Operation Privileged operation Execute Protection Addressing Specification Decimal data Fixed-point overflow Fixed-point divide Decimal overflow Decimal device Exponent overflow Exponent underflow Significance Floating-point divide ~§~~ A£!i2B: Enter DEBUG the PSW and registers at exception. 143S UNABLE TO LOAD SAVED [ 'ERROR CODE=nn] mode to exalllin$ the time of the SYSTEM OR LCAD MODOLB ~either a CMS segment EDMAIN load module is available. 1Z.I2!!~i2Q: n specified during a §l§!g!!! A£iig~: The system abends with abend code X'OCn', where B depends on the type 6£ exception. llElgnatiQll: Errors occurred while tryihg to issue the CP SAVESIS command to save the discontiguous shared segment. OCCUERED A1 command, 142T exception EXCEPTION OCCUBRED AT addr IN ROUTINE routine DURING 'SPIE' EXI~ ROOTINE 1 141T exception EXCEPTION ROUTINE called the nor an ~~g~ ~!l!.ing 2 - indicates DCSS was not available, and the CMS subset was active se the XBDMAIN module could not be loaded. DMS 4 - indicates DCSS was availatle but an error occurred while trying to load it. The CMS sutset was active and the XEDMAIN module could not be loaded. .§.lstn Acti.Q.n: BC = 110 Execution of the command is terminated. The system status remains the same. ~~ Action: Access a disk with an EDMAIN MODULE or use the SET command to ensure that the CMSSEG entry in the SYSNAMES table contains the name of an availakle CMS segment. 143T exception EXCEPTION OCCUBRED A~ addr SYSTEM BOUTINE called. IF! CMS again are defined in the lVSSECT ~!~! ~~!§ !~B ~2~!~1 §!2£! of the bggi£· !~LSP §l§!~ !£tio~: The CMS system halts loading a disabled wait state PSi • User Action: You can usIng-the CP command the wait state bit leaving the address type BEGIN. by continue processing by STOBE PSi to turn off ·in the virtual PSi, field unmodified; then Note, however, that the exception may have occurred in a vital system function, and so the system may no longer function properly. You may even lose your read/write disks. in 1115S INTEBVENTION REQUIBED CN {PBINTEBIPUNCH} !!£!~!!Q~: The specified hardware exception occurred in a CMS system routine. glplanation: This message is issued if: Systn !£!io~: The CMS system halts loading a disabled wait state PSi. • • by Us~~ ~ith The punch cr printer is not ready. Spooling space is exhausted while a file is being punched or printed. • FCB (3203/3211) does not match carriage control Note, however, that the exception may have occurred in a vital syste~ function, and so the system may no longer function properly. You may even lose your read/w rite disks. If this happens, IPL CMS again. BC = 100 If the punch or printer was not ready, the system status remains the same. If spooling space was exhausted, the file has been punched or printed up to the point where the space ran out, and the system operator has been notified of the condition. Acti~~: You may continue processing DEBUG) by using the CP command STOBE PSi to turn off the wait state bit in the virtual PSi, leaving the address field unmodified; then type BEGIN. §l§~~~ !£!io~: Q~ 1114S BEQUESTED FILE IS IN ACTIVE STA~US Ex!l!~atio~: The fileid specified in the EDIT command line is that of a file currently in use, or in active status. The read pointer for the file may be at any record in the file, which would cause that record to be read into storage by the Editor as the first record in the file. A subseguent FILE or SAVE command would result in loss of records pricr tc the first record read intc storage. This problem could exist if an EXEC is being executed which includes an EDIT command specifying the fileid of the EXEC. .§.l~!n Acti~~: terminated. The same. Execution of the command is system status remains the Actio~: Beady the punch or printer via the CP BEADY command. If spooling space was exhausted, ask the VM/SP system operator when spooling space will be available for punching or printing the file again. The form control buffer should be loaded if the printer was previously attached to a user or there is a mis-match tetween the FCB and carriage control. If the FCB needs to be loaded, refer to LOADEUF command in the operator's Guide. 111aT SYSTEM AEEND xxx CALLED FBOM 'addr' j!£l~D~ioD: The system detected condition that made it impossible continue execution of your program command •. a to or §l§~~~ Us~~ !cti~: Ensure that the file is not active when the EDIT command is issued. In the EXEC example, change the EXEC and issue the EDIT command separately. 1411T exception EXCEPTION CCCUEEED AT addr IN BOUTINE called WHILE 'UFDBUSY' = xx. IP! CMS AGAIN ~!!~: ·A program exception occurred in a routine that updates the user file directory for a read/write disk. The UFDBUSY flags are set. ~be UFDBUSY flags A£!i~~! The system clears any stacked input lines and allows you to enter jour next command. If you enter the DEBUG command, DEBUG mode is entered with the PSi and registers set as they were when the atend occurred. If JOU enter any other command, the abend recovery routine releases all your virtual storage and reinitializes the ccmmand handling mechanism before executing your next command. y§~~ Actio~: Enter a valid command. Con versational Monitor System (CMS) Messages 145 DMS 149T nnn (HEX xxx) DOUBLEWOBDS OF SYSTEM STORAGE HAVE BEEN DESTROYED. RE-IPl CMS EXEl!natiQB: In attempting to recover from a system abend, the abend recovery routine discovered invalid data in some critical system storage area. ~~§tem ActiQB: The CMS system halts loading a disabled wait state PSW. by continue opezating properly, and, in the worst case, you may destroy yout'tead/write disks. 153W 'HX' DURING ABEND PROCESSING WAS IGNORED A1Els!!!!io!!: 'HX' was typed whilE the ahend processing routine was in progress. .§.Y§!~l!! Q§~ ActiQB: If you wish tc continue abend recovery, use the CP STORE command PSW to turn off the wait state bit, leaving the address field unmodified; then type BEGIN. However, the system may be unable to continue operating properly, and, in the worst case, you may destroy your read/write disks. ActigB: The system ignores the 'HX' and continues abend processing. ~~~ Action: None. 154T SAVE AREA FOR SVC CALL ALLOCATED llEls~!io!!: 150W nnn (HEX xxx) DOUBLEWOBDS Cl SYSTEM STCRAGE WEBE NOT RECOVERED available to SVC. FROM addt CANNOT BE Insufficient free storage is allocate a save area for an .§1§!~!! EXElanatioB: In attempting to recover from a system abend, not all system storage was recovered. ~st~ ActiQB: Abend recovery proceeds as if storage recovery had been successful. Q§~~ ActiQB: You may continue Frocessing; your program should be executed correctly. Note, however, that the amount o~ storage available to your program is reduced by the amount shown in the message. As:!ig!!:The system is terminated abnormally with abend code X'nFO'. As:!i£B: If the abend was caused by an error in the application program (such as an unending loop), fix the . 'program and retry. If not, use the CFDEFINE command to increase the size of your vlrtualstcrage, IPL CMS again, and reissue the command. ~§~~ 155T USER ABEND nnnn CALLED FROM addr A1ElsBs!io!!: An abend macro was executed at th~ specified location. 151E 3278 MOD 5 DISPLAY TERMINAl BY OLD CMS EDI~OR NeT SUPPORTED ~l§!~l!! EXEl~tiQB: The 3278 MOD 5 is a new display device and is net supported ty the old CMS editor. §..yst~l!! A£!iQB: termina ted~ The EDIT session is User Action: The 3278 MOD 5 display device may-be used under the system· product editor in edit compatibility mode. For details, refer to the System Product Editor Command and Macro Reference. snd User Action: The system clears any stacked -input-lines and allows you to type in your next command. If you enter the DEBUG command, DEBUG mode is estatlished with the PSi and ~e9isters set as they were when tbe .bendoccurred. If you enter any other comiDand,. the abend recovery routine releases allyo~r Virtual storage and reinitializes ~h~ C~iDmand handling mechanism before executing your next command. 156E {FROMIRECORD} 'nnn' NOT POUND - FILE 'fn ft fm' HAS ONLY 'nnn' RECORDS 152T SYSTEM ABEND xxx CALLED FROM addr 'UFDBUSY' = xx. RE-IPL CMS WHILE ~Z~l!~!ion: A system abend occurred in a routine that updates tbe user file directory for a read/write disk. The UFDBUSY flags are set. The UFDEUSY flags are defined in the PVSSECT of the VML~R IH!!! A!:~!§. ~£ ~!!:Ql ~lfS:! Lo~£. The FROM option was given in the command line or set up by the DEPAUliS command to specify the starting record of the copying operation, but the specified input file does not contairi that many records. !£1iQB: The system is terminated by loading a disabled wait state ~SW. ActioB= BC = 32 Execution of thecommatld is t.ermiliated. 'lhe system status remains the same, with the following exceptions! Us~~ • ~~§!~ ActioB: If you wish to continue abend recovery, use the CP command STORE PSi to turn off the wait state tit leaving the address field unmodified and type BEGIN. However, the system may be unable to 146 glEls~!io!!: IBM VM/SP System Messages and Codes ~1§!~~ If the APPEND option vasspeci£iedan~ the copying process bega~ before the error was discovered, rec6rds haVE been appended to the output file. DMS • • If the NEWFILE (the default), EEPLACE, or OVLY option was specified and the copying process began before the error was discovered, then CCPYFILE CMSUT1, on the o.utput disk, contains the records copied so far. If in multiple-output-file mcde, several output files may have been created before the error was discovered. For the XEDIT command, a issued that specified beyond the end of file. GE~ a subcommand was record number full. If so, more disk space must found. Issue the HACLIB MAP command determine the contents of MACLIB. 158E NO CMS/DOS PROCEDURE LIEBARY SUPPORT ~~E!2~g!iQn: CMS/DOS does not support the reading cr writing of the DOS/VS ~rocedure library from the user ~rogram. ~~§!~~ ActioB: RC = 100 Execution of the command is terminated. User User Action: Reissue the command, specifyi~a-valid starting record. be to Action: Correct the ten-byte field ($$BOPNLB) to indicate source library processing. Then reissue the command. passed--~-DMSOPL 157E LABEL 'label' NOT FCUNt IN FILE 'fn ft fm' ~zplanatiQB: The FRLAEEI cpticn was specified ~n the command line, but the given label was not found in the sFecified input file. 2Y§tem ActiQ~: RC = 32 Execution of the command is terminated. The system status remains the same, with the following exceptions: • • If the APPEND o~tion was specified and the copying process began before the error was discovered, records have been appended to the output file. If the NEWFILE (the default), REPLACE, or OVLY option was specified and the copying process began before the error was discovered, then COPYFILE CMSUI1, on the output disk, contains the records copied so far. User Action: Reissue specifying-a-valid label. 157S MACLIB LIMIT EXCEEDED {, WAS 'membername'} the command, 159T INSUFFICIENI STORAGE AVAILABLE IC DMSFREE REQUEST FBOH addr SATISFI ~!gBatioB: A DMSFREE reguest from the specified location could not be satisfied. If the reguest was variable, then even the minimum reguest could not be satisfied. ~I§!§! ActioB: The system makes nc further attempt to allocate storage, and takes further action depending on the ty~e of DMSFREE call that was made: • If the call was conditional (the ERR= option was specified), a return ~s made to the caller with a return code of 1. If the call was unconditional and made via SVC 203, a system abend occurs. was OF7 If the call was unconditional and was made by specifying TIPCALL=BAIR in the DMSFREE macro, a system abend OF8 occurs. LASI MEMBER ADDED User Action: In the case of conditional programmer has ~resumably anticipated an error situation, and no further action is required. In the case of a system abend, issue the DEBUG ccmmand to attempt recovery from the situation. reguests:-~he ~Z~!g~g~i£B: While files were being added to a MACLIB, either the maximum CMS file size (65533 items) was exceeded or the MACLIB disk space was filled. If the error was detected while writing the first ~Ember to a MACLIB, the last part of the message is omitted and message DMSLBM213W is also issued. Otherwise, the member name cf the last successful addition is dis~layed. 2Ystn Acti.Q1!: RC = 88 Execution of the command is terminated. All successful additions made befcre the limit was exceeded are ccntained in the MACLIB. 160S JOB CANCELED DUE TC PROGEAM REQUEST !!£!gBgtion: The job has been canceled either by a CANCEL macro issued frcm the user's program or from the CMS/DOS routine when an error was encountered during execution. ~I§!~~ !cti~B: User Action: Issue the LIS!FILE command to determine-If the number of MACLIB items is approaching 65533. If so, no more macros may be added to the MACLIE: it is at the CMS ~ile size limit. Generate another MACLIB. RC = 100 is given if CMS initiated the cancel. Otherwise the appropriate return code (from 0 - 255) will be passed back to the user (this is the return code passed from the user to DMSDOS). If the return code passed to DMSDOS is greater than 255, then DMS£OS passes a special RC=101. Issue the QUERY command to see MACLIB disk is approximately 97 User Action: If the cancel was initiated by the-user~ reguest, no action is needed. if the percent Conversational Monitor System (CMS) Messages 147 DMS If an error message precedes this message, follow the user action of the preceding message. DOS-formatted disk. 7 A specified CCW command is unsuPlorted in CMS/DOS. 8 An attempt has heen made to read from a disk not in CMS, DOS, or OS format. An invalid DMSFREE request was One of the following has occurred: 9 End-of-extent encountered lefore end-of-file on a DOS formatted disk. The number of doublewords requested was zero or negative. 10 No DOSCE was found for the associated with this request. 11 The disk associated with this logical unit is not accessed. 12 The disk associated with this request is not in a recognizable format (for example, OS, DOS, CMS). 13 In attempting to find the real Common VTOC Handler for a DOS formatted disk, the CMSBAM segment was not fcund. 14 The real Common VTOC Handler found in the CMSBAM DCSS. was not is 160T INVALID DMSFREE CALL FROM addr ~~]l!natiQB: made. • • For variable requests, the minimum request was greater than the maximum. (Note that this error is never detected if the maximum request can be satisfied. This point can be important where a program that has run successfull~ suddenly fails when less storage is available. ) ~~!~ AC!ign: The system makes no further attempt to allocate storage, and takes further action depending cn the tYFe of DMSFREE call that was made: file • If the call was condi tiona 1 (the ERR= option was specified), a return ~s made to the caller with a return code of 4. 15 The attempted supported. • If the call was unconditional and made via SVC 203, a system al::end OF7 occurs. 16 No free storage available this reguest. • If the call was unconditional and was made by specifying TIPCAll=BALR in the DMSFREE macro, a system abend OFS occurs. 17 The specified assigned. 18 Incorrect F1 label address specified on a PVTOC READ by address or PV'IOC WRITE b~ address reguest. 19 The CMS file specified request was not found. 20 The physical device assigned tc this logical unit is not the same as the device specified for this logical unit in the DOSCB. the case cf conditional programmer has presumably anticipated an error situation, and no further action is required. In the case of a system abend, use the EEBUG command to attempt a recovery from the situation. Us~~ Action: In reguest~-the 161S UNEXPECTED ERROR CODE Inn' eN 'SISxxx' !~]l!~!iQB: An error occu~red during an EXCP (SVC 0) request or during CVTOC, PVTOC, or CVTOC macro processing. Error codes 1-9 are for EXCP error codes; 10-20 are for OVTOC, PVTOC, and CVTOC. The error code indicates the type of error that occurred: Code l1~Mi!!g --1"- No channel program (s) (CCW) was specified in the CCE. address PVTOC request logical not to process unit is not for this ~1§!~~ !ctiQ'!!: RC = 100 Execution of the routine is terminated. User Action: Use the error code to determine-and correct the possible cause of error. 161T INVALID DMSFRET NUMBER nn CALL FROM addr, ERROR £~ElgDg!iQ'!!: 2 The logical unit specified is unassigned. in the CCB 3 The device specified for the lcgical unit in the CCB is unsupported. An invalid DMSFRET request was made from the specified address. The error number indicates the type of error that occurred: Error ]Q. 4 An invalid CCW command code was found. 5 5 The logical unit specified in the CCE is assigned to an unknown disk. 6 6 148 An attempt has teen made to write to a IBM VM/SP System Messages and Codes Meg!!illil The numler of doublewords was zero or negative. specified The block of storage being released was never allocated by DMSFREE. Such an error is detected if one of the D!S following is found: • The block does not lie entirely within those sections reserved for DMSFREE storage. • The block crosses a page boundary that separates a page allocated for TYPE=USER storage from a page allocated for !YPE=NUCLEUS storage. • 7 been destroyed. The block overlaFs another block already on the free storage chain. The address given for the block being released is not doubleword aligned. ~lst~~ !gti2E: The system makes nc further attempt to release the storage block, and takes further action depending on the type of DMSFRET call made: • If the call was conditional (the ERR= option was specified), a return is made to the caller with a return code of 5, 6, or 7. Since these storage pOinters are unprotected, a user program may inadvertently destroy them without getting a protection violation. The "internal error code" in the error message is for error analysis by system programmers. 2Y§1~ Action: The message DMSFRE165T. system first displays Next, the system attempts to recover sufficiently so that processing can continue at least to the point where abEnd recovery can be performed. It does this by zeroing out the chain header pointeIs for the destroyed chain. This effectively "loses" any storage that is on that particular chain, but it allows processing to continue. (Note that abend recovery will later recover all "lost" TYPE=USER storage. ) Further system action depends on the type of DMSFREE or DMSFRET call that was made: • If the call was unconditional and made via SVC 203, a system abend occurs. was OF7 • • If the call was unconditional and was made by specifying TYPCAIL=EALB in the DMSFREE macro, a system abend OF8 occurs. • If the call was unconditional and was made via SVC 203, then a system abend OF7 occurs. • If the call was unconditional and was made by specifying TYPCALL=BALR in the a system abend OF8 DMSFREE macro, occurs. User Action: In the case of conditional reguests;--the programmer has presumably anticipated an error situaticn, and no further action is required. In the case of a system abend, use DEEUG to attempt to recover from the situaticn. 162T VITAL FREE STORAGE POIN!ERS DES!ROYED (INTERNAL ERROR CODE nn), RE-IPL CMS ~~£lgng!~2E: A free storage management pointer in NUCON has been destroyed. The system cannot continue. The error code indicates the type of error that occurred: Code liSlAn1:1!.9 current low EXTEND value (FREELOWE) is greater than VMSIZE. -i~- The 85 The current low EXTEND value is below the beginning user of the area. 86 Bytes in FREETAB are valid range. not within the ~1§!~ !£!1:gn: The system is terminated by loading a disabled wait state PSW. Q§~~ As1ion: IPL eMS again. 163T {LOWIHIGH}-CORE USER CHAIN HAS DESTROYED (INTERNAL ERRCR CODE nn) If the call was conditional (the ERR= retuIn is made to the caller with a return code of 2. option was specified), a User Action: In the case of conditional ieguests;--the programmer has presumably anticipated an error situation, and no further action is required. In the case of a system abend, use the tEBOG command to attempt a recovery fIom the situation. 164T {LOWIHIGH}-CORE NUCLEUS STORAGE POINTERS DES!ROYED (INTERNAL ERROR CODE nn). RE-1PL CMS The chain of free-storage elements, from which DMSFREE storage with is allocated, has been !YPE=NOCLEUS destroyed. ~~.Elg!!g!~2n: §,l§!~~ !£.t1:2!!: The system is termina ted by loading a disabled wait state PSW. User Action: Issue the CP DUMP command to get-a-dump-of virtual storage, and save the output for your system programmer. Then IPt CMS again. BEEN 165T CHAIN HEADER AT addr: xxxxxx xxxxxx xxxxxx :XllXXXX 1!El~1ion: elements, from TYPE=USER (the The chain of all storage which DMSFREE storage with default) is allocated, has This message appears J,!Elanation: conjunction with messages DMSFRE163i Conversational Monitor System (CMS) Messages in and 149 DHS DMSFRE164T. It indicates the contents of the DMSFRE chain header tlock for the destroyed chain. .§l'§!~!!l ActiQ!!: See "System Action" messages DMSFRE163T and DMSFRE164~. 6 (DMSFRET) The block of storage that is being released was never allocated by DMSFREE. One of the following errors occurred: for • The block was not within eithEr the low storage free storage area or the user program area (bEtween FREELCWE and FEEUPPR). • The block crosses a page boundary that separates a page allocated for user storage from a page al1ccated for nucleus type storage. • The block overlaps another block already on the free storage chain. User Action: See "User Acticn" fer messages DMSFRi163T-and DMSFRE164~. 166T UNEXPECTED ERROR IN FREE STCRAGE MANAGEMENT ROUTINE (INTERNAL ERROR CODE nn). RE-IPL eMS. ExE!~!!~!iQ!!: The DMSFRE rcutine had an unexpected internal error. Furthermore, a check showed that all internal free storage pointers were valid. 7 .§Y§!~! !£tiQ!!: The system is terminated by loading a disabled wait state PSi. 8 User Action: Issue the CP DUMP command to get-a-dump-of virtual storage, and save the output for your system ~rcgrammer. ~hen IPL CMS again. 9 (DMSFRET) The address .given for the block being released is not doubleword aligned. (DMSFRES) An invalid reguest code was passed to the DMSFRES routine. Since all reguest codes are generated by the DMSFRES macro, this error code should never appear. (DMSFREE, DMSFRET, or DMFRES) Unexpected and unexplained errcr in the free storage management routine. 167S PREVIOUS MACLIB FUNCTICN NCT FINISHED .§lste~ ]ZElg!!atio!!: A MACLIB GEN, ADD, REP, or DELETE function issued for this MACLIE was ended (for example via a HX command) prior to normal completion • .§l'§!~!!l !£!.!Q!!: RC = 88 The current command is not executed. system status remains the same. User Action: The MACLIE unpredictable. Use the MACLIB to reconstruct the HACLIE. ActioB: The system begins to check all free storage pointers for consistency to see if any have been destroyed. The system displays further diagnostic messages when inconsistencies are discovered. !£!iQB: Check the the further diagnostic Froduced. ]g~ The status is GEN command "User Action" messages that for are 168S PSEUDO REGISTER TABLE OVERFLOW £~E!.9!!g!ioB: 167T FREE STORAGE ERROR CODE nn MANAGEMENT ERROR, INTERNAL ]Z.Elg~tiQ!!: An error occurred in the free storage management routine that handles DMSFRES, DMSFREE, and tMSFBET reguests. Code Error (DMSFREE) Insufficient storage space is available to satisfy a free storage reguest or the minimum reguest could not be satisfied on a variable reguest. 2 (DMSFREE or DMSFRET) User storage pointers destroyed. 3 (DMSFREE, DMSFRET, or DMSFRES) Nucleus storage pOinters destroyed. 4 (DMSFREE) An invalid si2e was reguested. This error exit is taken if the reguested size does not exceed zero. For variatle requests, the minimum reguest exceeds the maximum reguest. (However, the latter error is not detected if DMSFRE is able to satisfy the maximum reguest.) 5 (DMSFRET) An invalid size was ~assed to the DMSFRET macro. The specified length is not positive. ~-- 150 IBM VM/SP System Messages and Codes (START or LOAD/INCLUDE START). The Fseudo register index table is full. There are too many pseudo registers (external dummy sections) in the loaded files. This is a system restriction. Actio!!: RC = 104 Execution of the command is terminated. The system status remains the same. ..§..l§!~.!!l User Action: Correct and-try again. the Assembler program 169S ESDID TABLE OVERFLOW ~Z~!.9!!g!iQ!!: An external symbol dictionary identification table overflow has occurred. The maximum number of external names per text deck (START or first CSECT to end card) is 255. This is a system restriction. ActiQ!!: RC = 104 Loading stops. The system the same. .§ll!~ Ac!!QB: Divide your smaller units and try againr ]§gI status remains program into DMS 17~S DISK 'mode (cuu) , FILES HAS MAXIMUM NUMEER OF or OVLl option was specified and the copying process began before the error was discovered, then COPYFILE CMSU'I1, on the output disk, contains the records copied so far. !J]lanati~: 3400 files If any additiona~ files have been written. were written, the disk area that contains the file status table blocks would overflow. ~§!u !£li5m: RC = 10 The file is not written. remains the same. Q2~~ !ctigB: • If in multiple output file mode, several output files may have been created before the error was discovered. The system status User Action: coiiiiiia nd:---- Erase some files frcm Correct and reiSSUE the the disk. 174W SEQUENCE ERROR INTRODUCED IN , •••••••• , TO ••••••••• , 171T ~ERMANEN~ OU'IPUT FILE: CONSOLE ERROR. RE-IPL CMS glE!g~tig!!: !!ll.!an~tio!!: Either the terminal is not operational (for example, Start I/O trouble has occurred) or the status of the terminal is ~nexpected (for example, channel errors, or bad'~nterrupt sequence). §l§!!! !£tion: The system is terminated by loading a disabled wait state PSW. The wait state PSW contains the CMS nucleus addresswher~ the error cccurred. !!§~I!S;li.Q!!: IPL eMS again. 172E TO LAEEL 'label' {EQUAL S I IS SUaSTRING OF] FRLABEI 'label' AN The 'IOLABEL and FELABEL options were specified. Either both labels were egual, or the TOLABEL was an initial eubstringof the FRLAEEL label (as "AEC" is an initial substring of "AECE"). This is an error condition l::ecause it imFlies that no records whatsoever are to be copied to the output file. §l.§!~!!!: !£lim!: RC = 24 Executiono! the command is terminated. The system status remains the same. Acti9!!: command. 173E NO RECORDS ft fm' Correct and reissue WERE COPIEt 'Ie CtlTPtlT ActioB: RC = 8 The invalid sequence numbers are left in the records, which are written to the output file. Update prccessing continues, and, if the CTL option was specified, additional UFdate passes are made. §l§~~! INITIAL nWM.:!:¥m: !l!~I The updating procedure caused a sequence error to be introduced into the output file. That is, in the output file there were two records (with the seguence numbers shown in the warning message) such that the seguence number in the first record was egual to or exceeded the sequence number in the second. the If several warning messages are generated during the updating process, the final return code passed by the UPDATE command will be the highest return code (4, 8, or 12) associated with the warning messages. The REP option, if it was specified, will be ignored, and the final update deck will have the fileid "$fname ftype". See the explanation of message DMSUPD1771 for further information on the meanings of the UPDATE warnin~ return codes. y~~ Actien: Probably, the resequencing field following the "$" in the last update control card contained invalid data. Correct the invalid control card in the update file, and reissue the UPDATE command. FILE 'fn 175E INVALID EXEC COMMAND ~.!:.Pl.9!!il.ti.Q!!: The options sFecifiedfer the inlnrtfiles, qaused no records. to be copied. This will happen, for example, if the FRLABEL label appearsjn the first record of '. each-Cor the only) input file being copied to the output file. lli,!!J!Action: HC = 40 Execution of. the command is terminated. The system$tatus remains the same, with the following exceptions : • • If the APPEND option was specified and the copying process began before the error was. discovered, records have been appended to the outptit file. If the NEWFILE (the default), REPLACE, j!~!~g!io~: An error has been detected in the parameter 2ist to DMSEXE. RC = 10000 Execution is terminated at the point of the error. ~!~! Actig~: User Action: Correct the parameter list and reexecute-the EXEC. 176W SEQUENCING OVERFLOW FOLLOWING SEQ NUMEER Explanatio~: When the resequencing increment was added to the sequence number shown, the result overflowed the maximum Conversational Monitor System (CMS) Messages 151 DMS sequence number. If the S!Q8 option is in effect, the maximum sequence numbEr is 99999999. If the NOS!Q8 option is in effect, however, the Daximum sequence number is 99999. .§.I s t~ J£J:i.2.!!: RC User !£tion: Refer to the warning messages were issued and correct the errors~ that 1781 UPDATING 'fn ft fm' APPLYING 'fn ft fa' {[ APPLYING 'fn ft fm']} 8 The new sequence number is truncated on the left to 8 or 5 digits (depending on the status of the SEQ8 option). A sequencing error is introduced into the output file. I!R!!B2!ioB: The specified update file is being applied to the source file. This message appears only if theCTL option has been specified in the command line. Update processing continues, and, if the CTL option was specified, additional update passes are made. If several ~arning messages are generated during the u~dating process, the final return COdE passEd by the UPDATE command is the highest of the return codes (4 or 8 or 12) associated with the warning messages. System Acti.Qll: continues. The REP option, if it ignored, and the final fileid "$fname ftype". was specified, is deck has the u~date See the explanation of message DMSUPD1771 for further information on the meanings of the UPDATE warning return codes. Acti2B: Probably, the resequencing field following "$" in the last update control card contained invalid data. Correct the invalid centrol card in the update file, and reissue the UPDATE command. The updating prOCESS 179E MISSING OR DUPLICATE 'MAeS' CARD IN CONTEO! FILE 'fn ft fm' The CTL option was specified, but the control file did not contain exactly one 'MACS' control card. lll~ioll: Action: RC = 32 Execution of the command is terminated. The system status remains the same, with the following possible exceptions: ~l§!~ ~ 1171 WARNING MESSAGES ISSUED {'REP' OPTION IGNORED.} (SEVERITY Code .H~aning Sequence errors were detected in the original source file being u~dated. • If the DISK option was in effect, and if a file with the fileid "fname UPDLCG" existed on the output disk bEforE thE command was entered, this file may have been erased. • If the CTL option was in effect, and if a file with the fileid "fname UPDATES" existed on the output disk bEfore thE command was entered, this file may have been erased. • If update processing had begun before the error was detected, any or all of the following files may have been created on the output disk by the UPDATE command: 8 Seguence errors that did not fermerly exist in the original source file being updated were introduced in the output file during the updating process. UPDATE CMSUT1 $fname ftype fname UPDLOG - if the DISK option was in effect fname UPDATES - if the CTL option was in effect 12 Any other nonfatal error detected during the updating ~rocess has a return code of 12. Such errors include invalid update file centrol cards and missing PTF files. For the XEDIT command, the updating process continues. Acti£B: The severity value is passed back as the return code from the UPDATE command. In addition, if the REP option was specified in the command line, it is ignored, and the updated source file has the fileid "$fname ftype", as if the REP option had not been specified. ~l§te~ 152 If a file with the fileid "$fname ftype" existed on the output disk before the command was entered, this file may have been erased. nn) • ExE!~sti2B: Warning messages were issued during the updating precess. The severity shown in the error message in the "nn" field is the highest of the return codes associated with the warning messages that were generated during the updating process. The warning return codes haVE the following meanings: ~-- • IBM VM/SP System Messages and Codes User fIle Action: Correct the invalid control and-reIssue the UPDATE command. 1791 CCMPARING 'fn ft fm' WITH 'fn ft fm' jill.!1!atio,!!: The specified compared. ~I§!~~ files are being Actio,!!: Processing continuEs. DMS aissing files, and reissue the comaand. Q§§! Action: None. 182W S~QUENCE INCBEMENT IS ZEBO 180W MISSING PTF FILE 'fn ft fm' A sequence increment of zero was specified either in a "./ S" control card, or in the "S" field of a "./ I" or "./ B" control card. !lRl~io~: An AUX file indicated that the specified PTF file was to be applied as an update file, but the file ceuld not be found. Either the AUX file contains invalid data, or a PIF file is missing. Ex~lgnatio~: 'un§! ,A£ti.Q!!: RC = 12 Applicat~on of the PTF file is skipped~ Update processing continues, and, if the CTL option was specified, additional update passes are made. If several warning messages are generated during the updating process, the final return code passed by the UPDATE command is the highest of all return cedes (4 or 8 or 12) associated with the warning messages. The REP option, if it ignored, and the final fileid "fname ftype". was specified, is deck has the u~date See the explanation of message DMSUPD171I for further information on the meanings of the UPDATE warning return codes. Correct the invalid data in the AUX file, or use the ACCESS cemmand to access the disk containing the missing PTF file. ~.!!! = Action: Be 8 Although the warning message is issued, the sequence increment of zero is actnally used, in case that was what the user wanted. Update processing continues, and, if the CTL option was specified, additional update passes are made. If several warning messages are generated during the updating process, the final return code issued by the UPDATE command is the maximum of all return codes (4 or 8 or 12) associated with the generated warning messages. The BEP option, if it was specified, is ignored, and the final update deck has the fileid "fname ftype". See the explanation of message DMSUPD171I for further information on the meanings of the UPDATE warning return codes. y§§! Acti.Q!!: !£~: Unless you intentionally specified a seguence increment of zero, oorrect the invalid update control card and reissue the UPDATE command. Q§~ 181E NO UPDATE FILES WERE FOUND 1832 INVALID (CONTBOLIAUX) FltE CONTBOL CABD The CTL option was specified, but none of the update and PTF files specified by the control file and the AUX filets) were found. As a result, no updates at all were applied to the original source file. ~~~.Q!!: Syst§! A£E:.Q~: RC = 40 Execution of the command is terminated, since no updating can be performed. 1f the STK option was specified, the two lines of stacked data were placed on the stack before this error, so that they will still be available to an EXEC that inveked the UPDATE command. This situation mayor may not be an error situation. The return code, 40, is unisue in that no other UPDATE errer message has that value as a return code. Thus, the same EXEC can be used to assemble source files that have updates against them, and those that have no updates against them. The latter situation can be detected ty testing for a return code of 40, and by assembling the "fname" file rather than the "Sfname" file. Y§!£ ActioB: If this is not an error condition, no action need be taken. If this is an error condition, it is the result of either missing update or PTF files, or invalid data in the control file. Either correct the invalid data er recover the JJR1AB!!ig~: An invalid control card was found in an AOX file or a control file. ~J..§.!!'!!! Action: BC = 32 Execution of the command is terminated. ihe s1~tem status remains the same, with the following possible exceptions: • If a file with the fileid "Sfname ftlpe" existed on the output disk before the command was entered, this file may have been erased. • If the DISK option was in effect, and if a file with the fileid "fname UPDLCG" e~is~ed on the output disk before the coltmand was entered, this file may have been erased. • If the CTL option was in effect, and if a file with the fileid " "fname OPDA7ES" existed on the output disk before the command was entered, this file may have been erased. • If update processing had begun before the er~or was detected, then any or all of the following files may have been created on the output disk: UPDATE CMSUTl Sfname ftYFe fname UPDLOG - if the DISK option ConversaU.cnal Monitor System (CIlS) Messages was 153 DMS in effect. fname UPDATES - if the C~L oItion was in effect. For the XEDIT command, the execution of the command or subcommand is terminated. However, if multiple files were being edited, the editing session continues. In addition, the following information is displayed for both ~UX and CJNTROL files: 'fn ft':'invalid card' RECORD 'nn' ----» * where the asterisk (*) is positioned under the invalid character in the 'invalid card' displayed in th~ preceding line User card Action: Correct the invalid control andreissue the UPDATE command. For DMSPRE, correct the invalid control card and reissue the PRELCAr command. 184W ' . j 5' NOT FIRST IGNORED CARt IN UPDATE FIlE If several warning messages are generated during the updating process, the final return code issued by the UPDATE command is the maximum of all return codes (4 Ot 8 or 12) associated with the generated warnin~ messages. The REP option, if it was specified, is ignored, and the final update dECk has the fileid "Sfname ftype". See the explanation of message DMSUPD177I for further information on the meanings of the UPDATE warning return codes. User Action: Correct the invalid control in--the update file, and reentEr the UPDATE command. card 186W SEQUENCE NUMBER [' •••••••• '] NOT FOUND A sequence number spEcified by an update file control card could not be found in the input file. An input seguenc~ number higher than the one specified was faund. ~JE!~~~1ioB: A£!i£n: RC = 12 The input file is positioned at the record whose sequence number exceeds the seguence number being searched for. ~j£!~.!!l !.!.E!snati.Q!!: A ".1 S" control card was encountered in the update file, but it was not the first noncomment card in the update control file. ~§l~ !£1i£n: RC = 12 The invalid card is ignored. Update processing continues, and, if the CTL option was specified, additional update passes are made. If several warn1ng messages are generated during the updating process, the final return code issued by the UPDATE command is the ~aximum of all return codes (4 or 8 or 12) associated with the generated warning messages. ~he REP option, if it was specified, is ignored, and the final update deck has the fileid "$fname ftype". See the explanation of message DMSUPD177I for further information on the meanings of the UPDATE warning return codes. • I£ the invalid sequence field was the first argument of a ".1 R", ".1 In, or ".1 D" operation, all rEcords encountered up to that point ~ere copied to the output file. • If the invalid sequence field was the second argument of a ".1 R" or "./ n" operation, records encountered uF to that point were not copied, and so were, in effect, deleted. In any event, no further deleting or inserting takes place for that control card, and any cards fcllowing this card, up to the next ".1" card in the update control file, are ignored. opdate processing continues, and, if the CTl option was specified, additional update passes are made. .Q§~I A,£.:ti.glP· Correct the update file by moving the"~1 S" control card to the beginning 6ftbe update file. ~hen reissue the UPDAT.E command. IN SEQUENCE If several warning messages are generated during the updating proces~. the final return code issued by the UPDATE command is the maximum of all return COdES (4 or 8 or 12) associated with the generated warning messagEs. 1.!lisnstion: An update file centrol card specified a·sequence number that contained an invalid character. Only the digits 0 through 9 may be used to specify a seguence number. The REP option, if it was specified, is ignored, and the final update deck bas the fileid "Sfname ftype". 185W {INVALIDINON NUMERIC} FIELD' •••••••• , §I§1.§.!!l !£li£n: CHARAC~ER RC = 12 The invalid update centrol card is ignored. Furthermore, any cards following it, up to the next ".I"card in the update file, will be ignored. Update processing continues, and, if the CTL opticn was specified, additional update passes are made. 154 IBM VM/SP System Messages and Codes • For the XEDIT command, the execution of the command or subcommand is terminated~ However, if multiple files were being edited, the editing session continues. In addition, the following information is displayed for both AUX and CONTROL files: 'fn ft':'invalid card' RECORD 'nn' ----» * DMS where the asterisk (*) is positioned under the invalid character in the 'invalid card' displayed in the preceding line See the "Explanation" of message tMSUPD177I for further information on the meanings of the UPDATE warning return codes. User Action: Correct the invalid centrol card in--the update file, and reenter the UPDATE command. 187E OPTION 'STK' INVALID WITHCUT 'CTI' EX.El.21lsli..2.!!: The STR option was specified with the UPDATE command. This option reguires the CTL option, rut CTL was not specified in the command line. RC = 24 Execution of the command is terminated. The system status remains the same. ~~~!~! AC!~QB: ActiQB: RC = 4 Execution of the command continues. All REP contrel records are ignored until the next NAME er END centrol record is encountered. ~I§!§! User Action: Enter an even number of digits ana-reissue the command. 193W PRECEDING CONTROL RECORD FLUSHED. !~.Els~s!iQB: The NO GO switch was set by a previous control record and has not been reset. A£!ioB: RC = 4 Execution of the command continues. §l~!§! User Action: A previous error message was issued:-Check the "User Action" for that message. 1945 EOOK 'subl.book' CONTAINS BAD RECORDS User Action: Reissue specifying the CTL option. the command, l~.Els~s!iQB: The book being copied contains invalid source statement library records. 190W INVALID CONTROL RECORt OR NO GO SWITCH SET ~~£!s~!~QB: Either the input control record was invalid or the NO GC switch was previously set. If the Ne GO switch was not previously set, the input control record is invalid, and this causes the NO GO switch to be set at this time. RC = 4 Execution of the command continues. All REP control records are ignered until the next· NAME or END contrcl record is encountered. ~~st~.!!! !ct~QB: Us~ Action: Determine error -alla--correct it; command. the cause of then reissue the the §1§!§! Act~QB: RC = 100 Execution of the cemmand is terminated. The system status remains tne same. A£tiQB: Recatalog the book on the system or private source statement library and reissue the command. ]~f 194W CSECT NOT FOUND IN 'membername'IMODULE 'modulename'} GO SWITCH {MEMEER SET Ne .1.!E!anatioB: The specified CSECT was not found in a library member or a module loader table. RC = 4 Execution of the command continues. All control records are ignored until the next NAME or END control record is encountered. ~Y§!~~ Acti~~: 191W PATCH OVERLAPS - SET Ne GC SWITCH Ex£1g~~!QB: The VER or REP displacement, or the DUMP start or end address, did not fit completely within the CSECT or MCDULE. HC = 4 Execution of the command centinues. All REP control records are ignored until the next NAME or END contrel record is encountered. User Action: The control record with the invalid CSECT name has teen printed at the printer or displayed at your terminal. Check the member or module for the fro fer CSECT name and reissue the command. ~~st~.!!! Act~QB: Q~~f Action: Correct the displacement field or the start or end address of the centrol record and reissue the command. 192W ERROR SWITCH. ODD NUMBER OF DIGITS ~ SET NO GO Ex,ElanatiQB: Either an address or a data field of a control record had an odd number of digits. 195W BASE VALUE INVALID - SET NO GO SWITCH !~.ElgEg!io~: The BASE address did not match the CSECT address. ActiQB: RC = 4 All Execution of the command continues. REP control records are ignored until the next NAME or END control record is encountered. ~lltem User Action: Insert the froper address in the- BAS~control record and reissue the cemmand. Conversational Monitor System (CMS) Messages 155 DMS 1961 PRT cuu SETUP COMPLETE encountered. l~Elgnation: The virtual 3800 printer setuF has been completed. ~~st~! ActiQB: All the LOAD commands specified in the SETPRT call have been issued and the current specl file remains open for printing of data in that spool file. ~§~f J£!iQB: Determine the proper control information and correct the VER ccntrol record. Delete from the input stream any other VER-REP pairs that were processed successfully, and then reissue the command. 201W THE FOLLOWING NAMES ARE UNDEFINED: Exp1~tioB: A list of names of unresolved external references is displayed. 1975 UNDIAGNOSED ERROR FROM PRINTER 'OOE' Ex]l~atioB: An undiagnosed error occurred while trying to perform I/O to the device. ~§!~ !£1ign: Return Code None. NOTE: A name entered with the command is considered an unresolved external reference if no text file with that name can be located. JctioB: RC = 4 Loading is completed. ~ll!~ = 100 ~§~I !£!iQ~: User Action: Use the CP DETACH command to detach the-3800 that has something wrong in its definition. Then redefine it via the CP DEFINE command and try to reissue the command. 198E SETPRT CAUSED A LOAr CHECK - SNS=ssssssssss ]Z£!SBg!i~: A load check was caused by the SETPRT command. ~§!~! Action: All output to the 3800 (up until the LOAD CHECK occurred) has been placed on the spool file. User Action: Find out why the particular modu1e--Caused a Load Check (possit1y by interpreting the returned SEnse bytes 'ssssssssss') and correct the Frob1em or specify a different module. In any case, close the virtual 3800 with the PURGE option and reissue the SETPBT command with the correct parameters. None; or ottain access to the files containing the unresolved references and issue the INCLUDE command. 202W DUPLICATE IDENTIFIER 'identifier' Explanation: A CSECT or entry point name was encountered more than once in the input stream to the loader. ~ll!~ J£!ioj!: RC = 4 Only the first CSECT is loaded. Program execution may not proceed as expected. All references are resolved to the first name. ]§~f JctioB: Reassemble the program ~ith a different identifier substituted for the duplicate. 203W "SET LOCATICN UNDEFINED COUNTEB" NAME 'name' J~lgnation: A name was specified on an SLC card in the loader input stream and that name had not yet occurred as an external name in the loader text file. 199E PRT 'OOE' NOT A VIRTUAL 3800 ExElgnation: The 'OOE' printer was defined as a virtual 3800 printer. not ~§!~! A£tiQB: RC = 4 The card is ignored. Q§~I ~~§!~ ActiQB: No output in the SFoo1 file. User as-a Action: Redefine the virtual printer virtual 3800. Then reiSSUE the SETPRT command. 200W VERIFY REJECT - SET NO GO SWITCH ]z£!anatiQB: For DMSZAP, the data on the VER or VERIFY control record is not exactly the same as the data at the specified location in the specified file. !£!iQB: RC = 4 Execution of the cemmand ccntinues. All REP control records are ignored until the next NAME or END centrel record is 156 IBM VM/SP System Messages and Codes Non~; or check the name on the 204E TOO MANY WCGM'S NEEDED FOB 'CHARS' ~]E!g~!iQB: The collection of Character Arrangement Tables specified in the command line denote more WCGMs to be loaded than are available for the virtual 3800. (4 if 4WCGM is in effect and 2 otherwise). !£!iQB: Nothing the virtual 3800. ~stem Q§~I S!st~! A£!iQB: SLC card. is transferred to ActiQB: Reissue the command with a collection of CHARS values that will fit into the WCGM space for the virtual 3800. DItS 205E NO FILES IN YOUR READER EX,Elanation: There virtual reader. were no files in your Syst!l! Acti.Q!!: RC=28 Processing is terminated. User Action: None. 205W READER EMPTY OR NOT READY E XllsBllill: contains no readied. Either the files, or it !£!ign: RC = 12 The invalid seguence fields are ignored, and processing continues. However, an incorrectly seguenced source file cannot always be proFerly updated. .§.I§!~ card reader has not been The card reader may contain a file spooled from a virtual punch or printer that contains CCWs only, and no data. Thus, this message is issued even though the file contains no data. Action: RC = 8 Execution of the command is terminated. The system status remains the same. .§.I§!~ User Action: Close the cared reader and reissue the-command, if the reader contains any files. 206W PSEUDO REGISTER ALIGNftENT EREOR Ex]lanation: A pseudo register with the same name as a previous pseudo register but with more restrictive alignment was encountered. ActiQ!!: RC = 4 Frocessing continues. All refetences te the particular pseudo register will have the less restrictive alignment. Update processing continues, and, if the CTL option was specified, then additional update passes are made. If several warning messages are generated during the updating process, the final return code when the UPDATE command has completed all processing is the maximum of all return codes (4 or 8 or 12) associated with the generated warning messages. The REP option, if it was specified, is ignored, and the final update deck has the fileid "$fname ftype". See the "Explanation" of message DMSUPD1771 for further information on the meanings of the UPDATE warning return codes. For XEDIT, the execution of the command or subcommand is terminated. However, if multiple files were being edited, the editing session continues. In addition, the following information is displayed for both AUX and CCNTRCL files: 'fn ft':'invalid card' RECORD Inn' ----» Where the asterisk (*) is positioned under the invalid character in the 'invalid card' displayed in the preceding line. * User Action: Correct the invalid ccntrol card in--the update file, and reenter the UPDATE command • .§.Ist~!!! Us~ 208E FILE 'fn ft' IS NOT VARIABLE RECORD FORMAT Explanation: The specified file have a variable record format • Action: None. did not RC = 24 Execution of the command is terminated. The system status remains the same. .§I§!~!!! Ac1io~: 207W INVALID UPDATE FILE CCNTRCI CARI EX,Elanation: An invalid control card was found in the update file. Seme of the errors that cause this message to be issued are: • The first card in the update not a control card. • The first card following a "./S" or a "./D" or a ".1*" was not a centrol card. • The operation field invalid, or contained character. Use.f Action: Verify that 'fn ft' is the desired file. If it is, use the COPYFILE command to change the record format cf the file. file was 209W FILES DO NOT COMPARE was more missing, than one Explanation: The two files the user reguested compared on a line-for-line, column-for-column basis, do not match. • The label field ef a "./S" card contained more than three characters. System Action: RC = 4 The comparison of the files The lines that do not match at the terminal. • An invalid Seguence field was specified, or a reguired sequence field was missing. User Action: You can correct the file containing the incorrect lines using the EDIT command. • In a "./D" or "./E", the delete or replace ending specification was smaller than the starting specification. is cOllpleted. are disFlayed Conversational Monitor System (CMS) Messages 157 DMS 210E {LIBRARYIFILE} DISK. 'fn ft· IS ON A BEAt/ONLY User Action: crna n-d-.-- Correct and reissue the l~E!~natiQB: The specified file or library is on a read-only disk and must be on a read/write disk. .§,Iste,!!! Act.!.Q.B: RC = 36 Execution of the command is terminated. The system status remains the same. User Action: Verify that the correct file or-ribrarY- was specified in the command. If it was, either access the disk in read/write mode, or erase the existing file or library with the same name. Reissue the command. 210W INPUT FILE SEQUENCE EERCR: ••••••••• TO EXE1anatiQB: In reading the input source file, two records were found, with the displayed sequence fields, such that the sequence number in the first was equal to or greater than the sequence number in the second. !cti.Q.B: BC = 4 The invalid sequence fields are ignored, and update processing continues. However, an incorrectly sequenced source file cannot always be properly updated. .§,I§!~!!! If the CTL option was specified, then additional update passes are made. If several warning messages are generated during the updating Frocess, the final return code when the UPDATE command has completed all processing is the maximum of all return codes (4 or 8 or 12) associated with the generated warning messages. The REP option, if it was specified, is ignored, and the final uFdate deck has the fileid "$fname ftype". See the "Explanation" of message t~SUPD177I for further information on the meanings of the UPDATE warning return codes. 212E MAXIMUM NUMBER OF RECORDS EXCEEDED 1~1~~!.!~.!!: The storage size of the virtual machine is not large enough to contain the size and number of sort files specified. !£ ti 2.!!: RC = 40 Execution of the command is terminated. The system status remains the same. §Y§!~'!!! User Action: Compute the storage size ieguired for this sort using the format given in the description of the CMS SCRT command in the !~SP ~~E Co.!!!~g ~.!!g Ma~~Q ~~feren~~. Redefine storage as large as necessary using the CP DEFINE command, and issue the SORT command again. 213W LIERARY 'fn ft fm' NOT CREATED files to be E.!.Elanatio.!!: None of the included in the library file could be found, or the last active member of a library was deleted. RC = 4 Execution of the command is terminated. The system status remains the same. The new library is not created. Also, for DMSIEM and DMSLBT, the library is erased if the last active member has been deleted. ~y§!~.!!! !£!.!~.!!: User Action: For DMSLBM and DMSLET, obtain and/or correct the spelling of the namES and reissue the command if you were doing a generation function. If delete was the last function, no action is necessary. For DMSDSL, no action is necessary. access-~-the desired file 214W CANNOT RECOMPUTE CHANGE WITHOUT LOSS OF DATA. NC £~.El~.!!~ti~B: For XEDIT, the execution of the command or subcommand is terminated. User Action: Correct the invalid source file ana-reissue the UPtATE command. 211E CCLU~N FIELDS OUT OF SEQUENCE Ex..E.!anatio.!!: One of conditions has occurred. • • Start column number. the numler exceeds following User Action: Either erase some of the files or increase the number of cylinders to be formatted and reissue the command. 21ST NO VIRTUAL CONSOLE ATTACHED. RE-1PL CMS the ActiQ,!!: RC = 24 Execution of the command is terminated. The system status remains the same. V~/SP !ct.!2.!!: RC = 8 Execution of the command is terminated. The system status remains the same. end column Column number entry overflows eight-position option field. IBM ~~~.!!! on--the-~Isk .§.I§!~.!!! 158 The number of cylinders specified in the FOEMAT command cannot contain all the data on the disk. System Messages and Codes E~1gBg!io.!!: The user virtual console. §J§!~'!!! has disconnected his Action: The CMS system uses a special Interface with CP to disFlal this message. It is then terminated by loading a disabled wait state Psw. User WItii Action: Redefine a virtual ccnsole theCP DEFINE command, and IPI CMS 223E NO FILEMODE SPECIFIED EJ~!g~gtion: again. A filemode was in the command line. 216E INSUFFICIENT BLOCKS ON DISK STBUCTURE tISK TO SUPPORT CMS not specified RC = 24 Execution of the command is terminated. system status remains the same. .§'yst~ !ct!~H!: ~be !!~lsns!i2B: The user has reguested the formatting of a minidisk area that is not large enough to contain the essential CMS di..S!k st ruct ur e. RC = 100 Execution of the command The disk is unchanged. ~~st~! Actig~: terminated. l~lanatio~: ACti2B: Acguire a larger minidisk and reissue the command; or if the disk is large enough, specify a larger nuaber of blccks to be formatted in the FORMAT command. 220R ENTER DATA SET NAME: ExElAnation: A command was entered with the Ihe ccmmand ex~ects an OS data set name or DOS fileid to be entered. ? or DSN 7 operand. The system command, the 224E fileid ALREADY IN USE is Q§~~ Syste! !ct!Q~: response. User Action: Reissue specifying-a-filemode. waits fcr a A dataset name exists in an outstanding FILEDEF with a different ddname but with the same fileid, or a dataset name was specified for a fileid previously defined under a different ddname. .§'y§!g! !ct!~: RC = 24 Execution of the command is terminated. The system status remains the same. User Action: Clear the existing fileid before reissuing the command or specify a different fileid. 2251 PDS MEMBER 'membername' MOVED ~J~lgnat!~: User Action: Enter an CS data set name exactly-aS-It appears in the data set (in the form g1<.g2.gn) where g1, g2, and gn are the gualifiers of an OS data set name). Or enter a DOS fileid exactly as it appears in the file. The specified member of an OS PDS (partitioned data set) has been moved successfully to a CMS file. Syst~ Ac!!g~: MOVEFILE continues FDS members to CMS files until the the file is reached. moving end of 221E INVALID DATA SET NAME !!El~~~: DOS file-id line. An invalid OS data set name or was specified in the command 226E NO DATA SET NAME ALLOWED WITH FREE CPTION E~J&Bstio~: ~~§!g! !£!i@: Re= 24 EXEcution of the command is terminated. The system status remains the same. User Asion: Reissue valid data set name. the command with a A data set name must not be specified with the FREE option of the lISTDS command. !gtion: RC = 24 Execution of the command is terminatEd. The system status remains the same. ~1§~! .!!§~~ !g!io~: Correct the command line and retry. 222E I/O EBB OR READING {'fm'IOSIDOS} DISK 'datasetname' FROM 2261 END OF PDS MOVE ]~E!~s~: An I/O error cccurred while reading the specified os data set or DOS file from an OS or DOS disk. For DMSLDS, an I/O error occurred while reading the member directory in DMSROS. Syst~! = Acti2B: RC 28 Execution of the command is terminated. The system status remains the same. User Action: Correct the cause of error-ana-reissue the command. ~~anati~: The last member (partitioned data set) has successfully to a CMS file. of the PDS been moved .§'y§!g! !ct!~: Execution of the ccmmand is terminated. The system status remains the same. the I/O Conversational Monitor System (CMS) Messages 159 DMS 2271 PROCESSING VOLUME set name' 'nne IN EATA SET 'aat~ £gge MeSlni,!lg 80- An I/O error occurred while an as data set or DOS file was being read or an as or DOS disk was detached witheut being released. ]zplana!i2a: The specified OS data set Q~ DOS file is multivolume. The number of the volume being processed is sFecified ~n the error message. End of voluae is treated as end of file and there is no end-of-volume switching. ~st~ 81 The file is an as read-password-protected data set or a DOS file with the input security indicator on. 82 The as data set or DOS BPA!, ESAM, or QSAM. 83 The as data set or DOS file has mere than 16 user labels or data extents. Action: Execution continues. 227W INVALID EXTENT 'fm' DISK POUND paR 'datasetname' ON file is not ~lst§! A£!!2~: RC ::: 80, 81, 82, or 83 Execution of the command is terminated. !he system status remains the same. ]zplanation: The high extent for the subject data set indicates a relative track number lower than that fer the low extent of the data set. ~§§~ A£~~: If the error code is 81, 82, or 83, you cannot use CMS as access to read the as data set or DOS file. If the error code is 80, make sure the accessed as or DOS disk is attached, or determine the cause of the error. If the as data set or ~OS file is valid, reissue the command. Syst2 Acti,Q.!!: RC ::: 4 Execution continues. Us~ Action: Par fUrther investigation, use the CMS command DDR to locate and'dump th~ DSCB containing the invalid extent. 2291 NO MEMBERS 228E NO DDNAME ENTERED IJB1!R!!i2!!: No members partitioned data set. !!]!snstion: When prompted for the ddname corresponding to the "dname" entry for the tape dataset in the Access Met~od Services control statement, the user entered a null line. .§,Ist§!!l ActiQ,B: RC = 24 AMSERV does not execute the Access Met~od Services job. The system status remains thE same. User Action: Find the "dname" entries fOr the-tape--dataset(s) in the ACCESS MethOd Services jobstream a~d reissue t~e AMS~RV command. 2281 USER LABELS BYPASSED ON name' DA~A SE~ 'data set Explanation: The specified AS data set or DOS file has a disk user label. !he user labels are automatically skiPFed and the DCBEXLST routine, if specified, is igDored. This message is issued when the OS Fi~e Status Table (FST) is created. This occurs during the execution of t~e first PILED!' command defining the OS ddname. Reissu~n9 the same PILEDEF cemmand without reaccessing the disk does not create a new as FST, and the message is therefore not issued again. Syst§~ ActiQB: Execution continues. 229E UNSUPPORTED as DATA SET, [lEROR 'code'] ]z]lanation: The specified as data set Or DOS file is not supported ty CMS as access routines. The error code mea~in9s are: 160 IBM VM/SP System Messages and Codes FOU~D ~l§!§! A£ii£~: exist in a None. 2ser Ac!io~: Determine whether the data set you specified is the correct one and if so, why it contains no memkers. Correct the condition and reissue the command. 2~OE .0. OF VSAM EXIT ROUTINES HAS EXCEEDED MAX OF 128 - UNABLE TO CON~INUE The number of exit routines for VSAM data sets (both actiVE and inactive) has exceeded the maximum of 128 for the run unit. l!]lAB!tio~: §l§!§! A£1!g~: The system is terminated abnormally with abend code X'177'. ]§!! As!!~~: for the program. ro~tines Reduce the number of exit VSAM data sets and rEexecute 230W OS DISK - FILEID AND/OR ARE IGNORED OPTIONS SPECIFIED The specified as or DOS disk bas been accessed, but the specified filEid and/or options are not valid and haVE been ignored .. J!Rlj~i2!: ~.I§!!! Actio~: RC ::: 4 Execution of the command continues. DMS 231E I/O ERROR DISK READING VTOC !!Rla~: while reading disk. ~ An FRO! {'fm'ICSIDOS} I/O error was enceuntered the VTOC from the specified Aru.Q.!!: RC = 28 Execution of the command is terminated. The system status remains the same. ~£~: Correct the cause of error and reenter the command. 232E INVALID RECF! SUPPORTED SPANNEI the I/C EECCRDS NOT EXElanatiQB: The MOVEFIlE command USES thE GET and PUT macros in locate mode. the GET and PUT macros are not su~portEd for use with spanned records. ~!!. .!£U.Q.!!: RC = 088 problem persists, call personnel. your system support 235E ERROR 'n' IN INPUT TEXT FILE 'tn ft [fm]' J!R!iBj!igB: An error was detected within the data contained in the input tExt file. 'n' indicates the nature of the error; it may be one of the following: --, Code baning No valid ESD. 2 Invalid ESD type code. 3 Invalid RLD record. 4 Invalid ESD LD ID. 5 ESD LD entry precedes its position entry. 6 Invalid lXT record ISD ID. Syst!!. ActiQB: RC = 12 Execution of the cemmand is terminated. The system status remains the same. Execution of the command is terminated. ~§§£ y§!! Action: The user will havE to provide a utility/program to process the file. The READ and WRITE macros are supported for spanned records if the filemode numter is 4 and the data set is physical sEguEntial (BSAM) format. 2331 NO FREE SPACE AVAILABLE ON 'fm' DISK !!R!~BA!ion: All tracks disk are allocated. on the specified A£ti~B: If you can determinE the problem from the "Explanation" above and remedy the condition, reissue the command. If not, reissue the command and if the problem persists, call your system support personnel. The error may have been caused by invalid output from the Assembler. Reassemble the source for the text file in error and reissue the PRELOAD command. Errors also may result from the input text file having been incorrectly modified by the user through EDIT or other CMS commands. Y§!£ Action: If the disk is an OS or DOS disk, use one of the as or tOS utilities to reformat the disk (if yeu no lenger need any of the data on it) Or delete some data sets. If it is a VSAM disk, use Access Method Services to delete some clusters and data spaces. 2~4E ERRO~ IN LOAD LIST FILE 'fn ft fm' (NO INPUT] !!R!anation: During processing of the load list EXEC file, an invalid statement was encountered. Input must consist ot valid EXEC control words (that arE ignored) and names of input text files in thE form &1 ~2 filename [filetype] Filename and filetype (if specified) must not be more than eight characters in length. A "NO IN'UT" condition exists if after the scan of the load list, no filename filetype entriEs were found. System .!£tion: RC = 8 Execution of the command is ter.inated. The system status remains the same. . ~B: If you can determine the problem from the "Explanation" above apa remedy the condition, reissue the command. If not, reissue the co.mand ~nd if the 236E UNRESOLVED ENCOUNTERED EXTERNAL REFERENCE (S) Unresolved external references have been encountered. These are listed in the MAP file. J~]!ABgtion: '§l§tem Actio!!: RC = 4 The PRELOAD command has completed processing. Program execution of the output text file may not proceed as expected. correct the input, if necessary. 237E tUPLICATE EXTERNAL SYMBOL(S) ENCOUNTERED A CSECT or entry point name was encountered more than once in the inFut stream to the preloader. The duplicate symbols are listed in the MAP file. ~~gnation: .§l§!!!! Actio!!: RC = 8 the PRELOAD command has completed processing. Program execution of the output text file may not proceed as expected. ]§~ Q~ ~B: text file identifier Reassemble the source for the a different in error with substituted for the duplicate Conversational Monitor System (CBS) Messages 161 DMS option. and reissue the PRELOAD command. !ctiQ1!: RC = 4 Execution of the command continues. All REP control records are ignored until the next NAME or END control record is encountered. ~Y.2.t~! 238E PRELOADER PROCESSING ERROR Explanation: An internal error was detected during preloader processing. This may have been caused by invalid input. Acti.Q1!: RC = 16 Execution of the command is terminated. The system status remains the same with the exception that partial output files may have been created. ~st~! Q~~ Action: Reissue the command, ensuring that a valid load list file (and oFtional CNTRL file) are specified. Insure that the input files contain valid data. If the problem persists, call your system support personnel. 240S ERROR LOADING READ OS ROUTINE 'DMSROS TEXT' Q~ !£!ion: Either regenerate the module with the MAP option, or do not use a CSECT name; then reissue the ccmmand. 247W MEMBER 'name' NO! FOUND - SET NO GO SWITCH 1zE1~!!ation: The specified member was not found. Actio!!: RC = 4 Execution of the command continues. All control records are ignored until the next NAME or END control record is encountered. ~Y§1~! User Action: Reissue valId member name. the command with a ~z]lana!i.Q1!: Either the user did not provide a read/write A-disk for use by the CMS loader, or some other error was encountered while loading the READ OS routine DMSROS TEXT. ~st~ Action: Execution of the command is terminated. The system status remains the same. 248W INVALID VER/REP DISP - SET NO GO SWITCH £z]la~!ion: The displacement specified in a VER or REP control record includes an area that is undefined, for example, a Define storage (DS) area. !£1i£!!: RC = 4 Execution of the command continues. All REP contrel records are ignored until the next NAME or END control record is encountered. If the operation is REP, the file being oFerated on may be modified. ..§~!~ Us~~ ~ction: Access a read/write A-disk if one ~s not already accessed. If a read/write A-disk was provided, correct the cause of the I/O error on the system disk or A-disk. Then reissue the command. ]~~ 245S ERROR 'nnn' ON PRINTER An unrecoverable error occurred when writing a line to the printer, and an error code was passed to the calling module from DMSPIO. nnn indicates the nature of tbe error; it be one of the following: ~Zlli!!~tiQn: may Code l1~aning ---4- An intervention is reguired. 5 An unknown error occurred. 100 The printer is not attached. Acti.Q1!: RC = 100 Execution of the command is terminated. The output files contain all cbanges made up to the last control record oFeration. "§lli~ !Q!ion: If you can determine the problem for the above information and correct the condition, reissue the command; otherwise reissue the command and if the error persists, contact your system support personnel. Q§~ 246W NO LOADER TABLE PRESENT FOR MOLULE SET NO GO SWITCH ~l~nati.Q1!: 'fn'- A CSECT name was specified for a module that was generated with the NOMAP 162 IBM VM/SP System Messages and Codes !£1i~n: Verify that instructions or data are at a specific displacement and reissue the command. 2491 DUMMY LOG ENTRY IN FILE 'fn ZAPLOG fm' ~lanation: Under the ZAP command, a successfully completed REP was not follOWed by a LOG control record. In lieu of a user-defined entry, a dummy log entry 'NONAME' was written. Syst~~ Actio!!: continues. ]~ !£!~: Execution of the command None. 250S I/O ERROR OR DEVICE ERROR !!]l~~tio!!: An I/O error has occurred on the user terminal trying to display a HELP text file. An error message should have been issued by eMS or CP to describe t~e condition. !£1iQn: RC = 100 Execution of the command is terminated. The system remains in the same status as before the command was entered. ~~~1~! OMS ]§~ ActiQ~: Take appropriate action as described by the CMS or CP error message. 253E FILE fn ft fm CANNOT SUPPLIED PARAMETER LIST BE HANDLED WITH j!~!!~tio.!!: 251E HELP PROCESSING 'description' ERROR, CODE The specified file resides on a disk that can be handled with a STATE extended parameter list only. That means the specified file contains more than 65536 items. nnn Explanation: An error occurred during the formatting of a HELP text file, indicating an error in the file text. ~121g! Ac1i~.!!: Execution of termina ted. Code Meani.!!.9 80'- An output line lenger than 132 characters was formatted. Long output lines usually result when you neglect to set the format mode back on after it is set off. 802 An alphabetic parameter was found for a HELP format word that requires a numeric parameter. 803 A line was read that staLted with a period, but could not be recognized as a valid HELP format word. 804 You omitted a required paLameter for this format word. 805 HELP does not recognize the parameter specified on the fermat word line displayed. 806 807 808 254E Explanation: This message informs the user of the proper options to use the HELP facility. The message is issued with message DMSHLP003E (INVALID OPTION 'option'). a.Istem Action: RC None. is program the HELP CANNOT FIND THE INFORMATION YOU REQUESTED. IF NOT MISSPELLED, PLEASE ENTER 'HELP' FOR MENU SELECTION OR 'HELP HELP' FOR THE HELP COMMAND The file specified by your HELP request was not found on the accessed disk(s), or in the file directory of the '5' disk and 'y' disk (if accessed). The request may have been misspelled or incomplete. RC = 28 Execution of the command is terminated and system status remains the same. ~Y21g! Acti~: User Action: Correct the entry if in error oi--use-the commands specified to obtain available HELP files. 255T INSUFFICIENT STORAGE FOR EXEC INTERPRETER jAElana!ion: There is insufficient storage for the EXEC 2 interpreter to initialize itself. RC = 10096 Execution is terminated at the point of the error. ~!~ !cti~.!!: User Action: the-coiiiiiiand. 256S Redefine storage and reissue ESERV EXECUTION ERROR, CODE Inn' ~ZE!!~tio.!!: An error occurred during ESERV program execution. ~he error code indicates the kind of error that occurred. Code 1'!~'!!!'!!.9 --,- Not enough virtual storage for ESERV processing. available 2 Unsupported library macro the ESERV program. 3 Invalid FIND request generated as a result of an LBRFIND request issued by ESERV. 4 Invalid GET request generated as a result of an LBRGET reguest issued by ESERV. 24 User Action: Issue the command again with a proper option. program ~lanatio.!!: Syst~ Acti.Q.!!: RC = 12 Execution of the command continues and the line in question is ignored. 252E VALID OPTIONS ARE: DESC FORM PARM ALL user Action: Change the user parameter list to extended-parameter-list format. A number outside the permissible limits for a HELP format word was found. The limits are based primarily on 80 characters-line in HELP. User Action: None at execution time, hOWeveryQii should correct the file in question to prevent future messages or errors. = 88 the y~ The execution of a .IN,.Il, or .OF HELP format word would cause the left margin to move to the left of character position one. HELP has calculated a negative space count based on the format words contained in the test file. RC issued Conversational Monitor System (CMS) Messages by 163 DMS 5 An error occurred in opening source statement library. the 6 An LBRGET request was issued by ESERV but the source statement library was not OPEN. 7 An I/O error occurred accessing source statement library. the 8 An LBRGET request was issued by ESERV without a previous LBRFIND. Syst~ ActiQB: RC = q1 (Code 1 only) RC· = 256 (all others) ESERV program execution is terminated. User sure Action: If error code 1 occurs, make a larger amount of virtual storage is available for ESERV program Execution. For all other errors, contact your system support personnel. 260T VIRTUAL MACHINE SIZE TOO NON-SHARED COPY OF CMS SMALL TO IPI The CMS nucleus is designed to be used as a saved, shared system. An attempt has been made to use the eMS system in non-shared mode by IPLing by device address. Insufficient virtual storage is available to do this. ~~lanation: again, specifying NOSTOR in line. This causes updates to on disk. Otherwise, no necessary. the command be performed action is 301E 'SYSxxx' NOT ASSIGNED FOR DISK 'fm' ~lE1~~ation: No ASSGN command was issued prior to the DLBL command associating the named DOS logica~ unit with a CMS disk. Action: RC = 36 Execution of the command is terminated. The definition does not take effect. §l§!~~ User Action: Issue an ASSGN command for each o~the DOS logical units specified in the DLBL, and then reissue the DIBL command. 302E NO SYSxxx OPERAND {ENTEREDISPECIFIED} ~~E1~~!ion: No SYSxxx operand was entered to associate the specified disk mode with a DOS logical unit, or in the case of DTFCP, the DEVADDR operand was missing from the DTFCP macro and no SYSxxx was specified with the DLBL command. This message appears only if the user is in the CMS/DOS environment. machine enters Syst~ ActiQ!!: RC = 2q Execution of the command is terminated. The definition does not take effect. User Action: IPL the saved CMS system by itS-system name, or redefine your virtual storage to exceed the ending location of the CMS nucleus. IPL by device address again. User Actio~: Reenter the DLBL command specifying a DOS logical unit for each disk specified. In the case of DTFCP, specify a DEVADDR operand with the DTFCP macro and with the associated DLBL command. The virtual CP by loading a wait psw. ~st~ Acti~: 299E INSUFFICIENT STORAGE TO COMPLETE UPDATE 303E NO SYSxxx SATISFIES REQUEST Explanation: The update is being performed in storage but there is insufficient storage to insert the next update line. j~l~~tion: ActiQn: RC = q1 Execution of the command is terminated. The system status remains the same. §l§!~ ~ystem User Action: Issue the command again, specifying NOSTOR on the command line. This causes updates to be performed on disk. A request was made for LISTIO A or LISTIO UA, but no logical units satisfied the request. Action: RC = 28 Execution of the command is terminated. The system status remains the same, except when the EXEC option was specified and there was an existing $LISTIO EXEC file. In this case, the $LISTIO EXEC file is erased. 300E INSUFFICIENT STORAGE TO BEGIN UPDATE Explanation: An update is being performed in storage, but there is insufficient storage available to con.tain the entire input source file. .§ygm! A£li.2!!: RC = q 1 If the keyword STOR was specified on the command line, execution of the command terminates. The system status remains the same. If the keyword STOR was not specified, the update continues and is performed on disk. No RC = 41 is issued in this case. User Action: If RC 16q q1, issue the command IBM VM/SP System Messages and Codes User Action: Ensure request has been made. that the correct 304E INVALID OPERAND VALUE 'value' ~l~l~ation: The value specified is not valid for one of the following reasons: • It is larger than ten digits. • It is a nonnumeric value. • The number is track numbers. greater than 2 31 -1 for DMS • The number is greater BUFSP size. than 999999 for This message is also displayed if a null line is entered as the first specification for the EXTENT option of the DLBL command. System ActiQ!!: RC = 24 Execution of the command is terminated. The definition does not take effect. User Action: Reissue the command, specifying~e CAT option with a previously defined ddname, or issue a DLBL command for the user catalog ddname and then reissue the DLBL command for the subject data set. 308E 'mode' DISK IN [NON-]CMS FORMAT; INVALID FOR [NON-]CMS DATASET I~!g~tion: User Action: specifying the entries. Reissue the command, appropriate values for all 3041 UPDATE PROCESSING WILL BE DONE USING DISK Explanation: An update is being performed in storage, and there is insufficient storage available to contain the entire input source file. The keyword STOR was not specified on the command line. The update processing continues with the update being performed on disk. The user has specified a CMS fileid ("CMS fn ft") but references a disk that is in non-CMS (for example, OS or DOS) format. Or the user has specified a non-CMS fileid ("DSN datasetname") but references a CMS disk. The reference to disk include not only the disk mode in the command line but also the mode in MULT and EXTEN~ specifications. This message is also issued if the user specifies CMS for file identification but uses one of the VSAM options (for example, CAT or BUFSP) with it. ~yste.!!! ~lli~ ActiQ!!: continues. Us~~ The updating process Acti.Q.!!: RC = 24 The command is terminated with no change to the current definition of DLBL since the new definition does not take effect. Action: None. User dIsk Action: Reissue the command with mode appropriate for the data set. a 30SE INCOMPLETE EXTENT RANG! 3201 MAXIMUM NUMBER OF DISK ENTRIES RECORDED Exllination: Only the starting relative track number was specified for an extent range. The number of tracks must also be specified. A!£!~ation: The maximum number of disks have been specified for a multivolume VSAM data set. The system (S) disk cannot be a user disk. Action: RC = 24 Execution of the command is terminated. The definition does not take effect. ~tem Acti~: User Action: Reissue the command with the proper-eitent specifications including the number of tracks. .Y~~ ~lli~ terminated and stored. Execution of the command is the data set definition is Action: None. 3211 MAXIMUM NUMBER OF EXTENTS RECORDED 306E SYSxxx NOT ASSIGNED FOR 'IGNCRE' Explgnation: When the DUMMY operand is used for a data set, the logical unit address must have been assigned with the IGN operand before the DLBL command was issued. Syst~ Action: RC = 36 No new definition for the data set is created. If one already exists, it remains unchanged. User Action: Either reissue the DLBL command using a valid disk mode, or issue "ASSGN SYSxxx IGN" followed by the original DLBL command using the DUMMY operand. 307E CATALOG DDNAME 'ddname' NeT FOUND ExE!~!iQ!!: The user catalog 'ddname' referenced by the CAT option has not been defined by a previous DLBI command. System A£.ll.Q.!!: RC = 24 Execution of the command is terminated. The definition does not take effect. A!Blanation: Sixteen (16) extents have been specified for a VSAM data set. This is the maximum number of data set extents allowed. §y~~.!!! !~: Execution of the command is terminated successfully and the data set definition is stored, including tbe 16-extent specification. 3221 DDNAME 'ddname' EXECUTED NOT FOUND; NO CLEAR I!£!anation: No previous definition for 'ddname' had been specified. This includes the condition of a DLBL IJSYSUC CLEAR with no previous job catalog ddname (IJSYSUC) defined. §lli~ Action: Execution of the command is terminated. All definitions remain unchanged. Conversational Monitor System (CMS) Messages 165 DMS User Action: If the ddname was entered incorrectly; reenter the command with the correct ddname. Y§!f 3231 {JOBIMASTER} CATALOG DLEL CLEARED Exllination: The DIBL for the catalog referred to has been cleared atid is no longer active. System Action: If the JCB catalog is cleared,--all- other definitions formerly flagged as using the JOB catalog are no longer flagged as such. The message can be the result of a DLEL* CLEAR rather than a DLBL IJSYSUC CLEAR or DLEI IJSYSCT CLEAR, when the PERM option is not used when defining the catalogs. Q§~~ {DLEIIFIIEtEFllAEEIDEF}'s ~st~~ Action: No further action The system is terminated. .§1.§te~ occurs. Action: None. 330R ENTER VOLUME SPECIFICATIONS: EXElanation: The system expects you to enter the VSAM data set volume specifications because you specified the l'!ULT option. Syst~~ Action: Execution of the command waits until you respond to the specification request. If a null line is the first response, an error message (DMSDLE048E) is displayed and the DLEL command has no effect. Ctherwise, a null response after one or more lines of data signifies the end of the specifications. User Action: Enter data set volume specifications either on one line separated by commas or on separate lines. The final comma at the end of the line is optional and may be omitted. You must enter the filemode and, in the DOS environment, the DOS logical unit associated with that disk. Do not repeat the file mode specified in the command line. 331R ENTER EXTENT SPECIFICATIONS: Explanation: The system expects you to enter the VSAM data set extents because you specified the EXTENT option with the DLEL command. Syst~ Acti2n: Execution of the command waits until you respond to the specification request. If a null line is the first response, an error message 166 333E nnnnnK PARTITION TOO LARGE FOR THIS VIRTUAL MACHINE The specified number of bytes exceeds the size of the largest partition possible with this virtual machine. Explanation: No definition is in effect for the requested DLBLs, FILEDEFs, or LAEELDEFs. Us~ jctiQB: Enter dataset extent specifications on the same line separated ty commas or on separate lines with or without commas. You must enter the starting relative track number, number of tracks, filemode and, if in DOS environment, the DOS logical unit associated with that filemode. The extents must be in ascending order for each volume grouping in order for the command to execute properly. ~lE!gng1i2n: Action: None. 3241 NO USER DEFINED IN EFFECT (DMSDLE304E) is displayed and the DtEL command has no effect. Otherwise, a null line means the end of the specifications. IEM VM/SP System Messages and Codes .!illQn: RC = 24 Execution of the command is terminated. The system status remains the same. The old DOS partition size remains unchanged. User Action: Specify a smaller value. If the partition size is not an important factor in this particular session, issue SET DOSPART OFF and allow the system to compute its own partition size. 346E ERROR Inn' LOADING 'fn ft' FROM DISK ~1E!gng!i2B: The TEXT file specified in a modname caused an error while trying to 10AD-rt into user virtual storage. .§lltem None. ~: RC = 6 User Action: Fix does notcause a the command. the TEXT file so that it loading error and reissue 347E ERROR Inn' LOADING LIERARY 'libname' ~lE!gBS!i2B: A return code of Inn' was received from diagnose code X'74' when trying to load the Named System into user virtual storage. Syste~ Ac!io!!: RC 100 + 'nn' None. User Action: The action 'nn' as-follows: taken depends on Code Meaning The 'litname' specified does not exist. Reissue the the command with a valid 'libname'. 04-08 The 'libname' is currently active on a real 3800. DRAIN the 3800 and reissue the command. 12 The library containing the volid is CP-owned. Consult your system Des programmer for an explanation. 16 350E MODULE IS MARKED NOT EXECUTABLE The library containing the volid is not currently mounted. Have the VM/SP operator mount the volume. Then reissue the command. !~l~~: The module was marked not executable by the linkage editor, but an attempt was made to execute the program. Actio!!: Abend code = 15A or BC = 4 Execution of the program is terminated. (Abend code 15A for LINK, ATTACH, or XeTL; BC = 4 for OSRUN.) ~Y2tem A paging error cccurred. system programmer. Consult your 348E ERROR Inn' SAVING LIBRARY 'libname' Q~~f Expla~: return code of Inn' was received from diagnose code X'74' when trying to save the new version cf the named system from user virtual storage. ~~st~ A Action: RC None. = Action: Link edit, an executable version of the program and reexecute the job stream or reissue the OSRUN ccmmand. 3S1E MODULE IS MARKED ONLY LOADABLE 200 + Inn' ~lanation: User Action: The action asfollows: iIiDi' taken depends on The module was marked only loadable by the linkage editor, but an attempt was made to execute the program. Actio.!!: Abend code = 15A or RC = 4 Execution of the program terminates. (Abend code = 15A for LINK, ATTACH, or ICTL; RC = 12 for OSBUN.) ~Y21~~ Code 1!&sl!1:.!!.9: ~- The 'libname' specified does not exist. Reissue the command with a valid 'libname'. Q~~f 08 The 'libname' is currently active on a real 3800. DRAIN the 3800 and then reissue the command. 12 The library containing the volid is CP-owned. consult your system programmer for an explanation. 16 The library containing the volid is not currently mounted. Have the VM/SP operator mount the vol ume. Then reissue the command. Action: Make sure that the name is correct-.--If so, determine why the program was made only loadable by the linkage editor. Link edit, an executable version of the program and reexecute the job stream or reissue the OSRUN command. 352E INVALID SETPBT DATA IN FILE 'fn ft' 20 The space allocated ty the installation for 'libname' is not large enough to accommodate its new size after processing by this command~ Either use the DEL function to delete some modnames or have the installation allocate a larger area for 'libname'. Then reissue the command. A paging error occurred. system programmer. Consult the £~lanation: The SETPBT module represented by 'fn ft' does not contain valid SETPBT informa tion. ~~!~~ Ac!io!!: All output to the 3800 has been performed until SETPBT module was encountered. virtual invalid Q~~f !£!io.!!: Find out why the particular module caused the above error. Most likely, the module in question was not created with the eMS GENIMAGE command. In any case, close the virtual 3800 with the PURGE option. Either use a different module or fix the module that caused the error and reissue the SETPBT command. 349E INVALID LIBRARY 'libname' 360E INVALID RESPONSE 'response' Ex.P1~~: The first directory entry in 'libname' was not the name of the library itself. The named system was im~roperly formatted on the DASD. §I§ll!! Actio!!: None. Q§~ ~!2B: not been since it function 'libname' function. The named system had either created before or was destroyed was last modified. Use the GEN to create a new library called and then build it using the ADD Ex£l~~!ion: After prompting you for information, VSAMGEN/SAMGEN determined that your reply was invalid, either because you did not enter one of the choices given you in the prompting message or because you entered a value not valid for the entry being processed (that is, the storage location of the named system). If the message is issued after the storage location value is entered, the value violates one of the following rules: • • • Must be a valid hexadecimal value. Must be less than 16 megabytes. Must be greater than X'20000'. Conversational Monitor System (CMS) Messages 161 OMS !ctiQB: RC = 24 If this is the first time this message is issued for this prompt, VSAMGEN reads from the terminal after issuing the message, thereby giving you another chance to enter the correct information. If it is issued for the second time for the same prompt, VSAMGEN terminates, and the system returns to the CMS command environment. ~st~ User Action: If it is the first time the message is issued, reexamine the prompting message and enter the correct information. If it is the second time the messa~e is issued for this prompt, VSAMGEN has terminated, so you must restart the VSAMGEN EXEC. If the message is from SAMGEN, the EXEC must be restarted. 361! DISK 'mode' IS NOT A {CMSIDOS} DISK system status remains the same. ]§!I Action: ReissUe the valid starting address. CREA~ED 3631 sysname DOSLIE command with a ON DISK 'A' lXRlana~: VSAMGEN creates a eMS DOSSI! file from the object modules that make u~ the named system. System illill: None. 363R EN1ER LOCATION WHERE sysname WItt BE LOADab AND SAVED: VSAMGEN requires that the A-disk be a read/write CMS disk, and that the disk you specified as containing the DOS SRL be a DOS disk. AJRlanation: VSAMGEN/SAMGEN reguires a hexadecimal address for fetching the VSAM and/or Access Method services systems into storage so that the systems can be saved on a CP volume. Acti.QD: RC = 36 VSAMGEN has terminated. to eMS command mode. The system returns read to the response. Us~ Action: If the message concerns the CMS A-disk, access a CMS disk in read/write mode as the A-disk and reissue VSAMGEN. If the message concerns the DOS disk, either access the DOS disk and use that mode letter to answer the prompt during the next VSAMGEN attempt, or enter the correct mode of the DOS disk containing the JOS SBL during the next VSAMGEN attempt. ~I ~ig~: Ex~natioD: 2:lst~l! !£!~~~: VSAMGGEH/SAMGEN issues a terminal and waits for your Enter the hexadecimal address to the starting relative page number in the SlSPGNUM field of the NAMESYS macro entered in the DMKSNT module for the named system. 364E VM STORAGE NOT LARGE ENOUGH TO CONTAIN SYSTEM LOADlNG AT startadr TO endadr 1XBlanatio~: The virtual machine's storage must be large enough to allow SSK instructions to be issued for the complete load range of the saved system. 362E INVALID STORAGE PROTECT KEY 'key' ExRlanation: The storage protect specified was not decimal, 0 to 15. ~Y§!i! key syst~ ActiQB: RC = 24 Execution of the command is terminated. The system status remains the same. User Action: Reissue the command~ specifying a valid storage protect key. svst&!! jction: RC = 24 Execution of the command is terminated. The s1stem status remains the same. ]§i' ASl~~: Use the CP command OEFINE to redefine the virtual machine's storage to a value large enough to contain the saved system, and lEt CMS again. 3621 LINK-EDITING sysname ••• 364! FETCHING sysname ••• VSAMGEN is in the process of link-editing the modules that make up the named system in order to create a CMS DOSLIB file with the same name. Ex~lanation: Us~£ ~: None. EXRlsnation: The start address specified in the command line is not a hexadecimal address within the load range of the specified system. 168 IBM VM/SP System Messages and Codes VSAMGEN is in the process of fetching the phases that make up the named system from the CIS DOStIB file of the same name. The phases are fetched into storage in order to be saved (written) on a CP volume. ~ 363E INVALID STARTING ADDRESS 'startadr' Syst~ Acti2,B: RC = 24 Execution of the command is terminated. 1~lapation: ~he »0' A£1i2p: None. As.!!sJ!= None. 364R ENTER 'CMSVSAM' OR 'CMSAMS' OR G!N!RAT10N OF HEW SYSTEM(S) 'EOTH' rtiR !xRlanatioQ: The message gives you the choice of regenerating either one or both DMS of the named systems. response. VSAMGEN issues a read to the terminal and waits for your response. y§§~ ~§~ !f!i2~: Q§~ !£tiog: Enter a valid response. lSlion: to be saved. Enter the name of the system 3671 'modu1ename TEXT' WRITTEN ON DISK 'A' 365E SYSTEM NAME NOT SPECIFIED IlBlABAt~on: ExRlA~~: The system name included in the command line. was not Acti~: RC = 24 Execution of the command is terminated. The system status remains the same. If the message was issued by DMSVGN, VSAMGEN has read a reader file and written it on the eMS disk with the given name. The file is used in creating a new named system • .§.!~ User Action: Reissue valid system name. the command with a 3651 SYSTEM sysname SAVED ~Y!!~ Explanation: VSAMGEN/SAMGEN saVES the named system on a CP volume for subsequent use by user programs. Syst~ Us~ If the message was issued by DMSVPD, DMSVPD (called from VSAMGEN EXEC) has read the named replacement module from the DOS/VS PTF tape and has written it on the user's A-disk for subsequent application in the new VSAM or Access Method Services system. .!!!i~ Action: None. .!£li.2.!!: Non e. 3671 ENTER TAPE {INPUTIOUTPUT} DDNAMES: Act!.2.!!: None. Action: None. 365R ONE OR MORE OF THE TEXT FILES LISTED IN THE fn EXEC ARE MISSING. THE VSAM PP PID TAPE SHOULD BE ON TAPE DRIVE 181, ENTER: 'GO' IF TAPE DRIVE IS READY TO LCADPILE O~ 'QUIT' TO STOP GENERATION PROCESS IJplanation: You must supply the ddname of the tape input or output data sets to be used in the Access Method Services jobstream. The ddname in each case must match the "ddname" operand in the ACCESS Method Services control statement being executed (EXPCRT, IMPORT, or REPRO). ~~ !£!io~: response. Explanation: VSAMGEN has detected one or more of the VSAM files necessary to generate VSAM/AMS is missing. VSAMGEN expects the VSAM PP tape to be mounted on drive 181. The system waits for a .!!!i£! Action: Enter the ddname of the tape input or output data sets to be used. 3681 count MODULES HAVE BEEN RESTORED ~ystem !£li~: Us~ None. EXP!Anation: VMFDOS issues this informational message to indicate to the user the number of modules created on disk from a VSE/AF distribution tape. Actio.!!: Enter appropriate response. 3661 STARTING TO READ PTF DECKS PEOM READED ••• VSAMGEN is starting the 'UPDATE' procedure, during which the user is prompted for the names of the PTF decks to be applied to the new system. ExE!A~: Syst§.!!1 ~ !£ti~: 368R ERASB 'NO': None. Action: None. Explanatiog: VSAMGEN has link-edited the VSAM or Access Method services system and fetched it into virtual storage and is about to issue the CP SAVESYS com land for that system. For SAMGEN, the simulated VSE/AF SAM modules have been fetched into storage and SAMGEN is about to issue the CP SAVESYS command for the CMSBAM Dess. !£1i2.!!: The sysname DOSLIB? •• ENTER 'YES' OE J121!h!~: 366R ENTER NAME OF SYSTEM TO BE SAVED: System .a.vJill ,!,glill: None. system waits for The CMS DOSLIB file created during execution of the VsAMGEN EXEC (see meSsage DMSVGN363I) can be erased at this time. This message prompts you to indicate whether or not you want the file eraSEd. System ~: response. The system waits for a Action: Enter either "yes" or "no". Obly the 'yes' response will eraSE the file. ~ a Conversational Bonitor System (CMS) Messages 169 DMS 369E INVALID - RELEASE 31 OR LATER REQUIRED ~Istem A!llilliiQB: The release number entered in response to message DMSVGN369R is an earlier release than the one supported for VSAM and Access Method Services. Systru! Acti.Q!!: RC = 24 VSAMGEN is terminated and the system returns to the CMS command environment. User Action: If the release number is the VSAMGEN EXEC procedure and enter the ccrrect number. Otherwise, see the description of CMS VSAM and Access Method Services in the !!LSP incorrec~- restart Qyi£!· Pl~nning ~~£ ~Y§~~ ~~~~~!~i~n 370R ENTER 'GO' IF SAVED SYSTEM CREATED, OTHERWISE 'QUIT' IS TO BE ~XElanation: The VSAMGEN EXEC has created the specified DOSLIB as stated in message DMSVGN363I and now reguires whether it is to continue processing the DOSLIE or is to be terminated. ~~~~ Action: response. The system waits for system waits for a Actio!: If you do Dot want to apply the PTF contained in the named file, enter "no". If you do want the file, indicate an EOB by pressing ENTER on a 3277 display terminal or RETURN on a 2741 terminal. Y§~I 400S SYSTEM 'sysname i DOES NOT EXIST jZB!~n: The subject system has not been defined in the Control program module DMKSNT .. !£!i2!: For DMSVIE, CMS abends with abend code X·044'. For all other modules, RC = 44. Execution of the user program is terminated. The system returns to the state it was in before the start of the user Frogram .. ~I§!~ ]~ ActioB: Contact the system programmer, who will generate the saved system for the correct system name. 4015 VM SIZE (size) CANNOT START ADDRESS (address) EXCEED 'sysname' ~AE!~natio!: 371R sysname IS LOADED. ENTER CP MODE ZAPS, ELSE 'NULL' The user's virtual machine storage size as currently defined is of such a size that the named system (when loaded) would overlay part of the user's virtual storage. This could have occurred in either of the following ways: 1. The named system was saved below the user's current virtual machine size, or 2. The named system was saved at an appropriate address, but the user's current virtual machine storage size is so large that it would be partially overlaid by the named system. TO APPLY FXB~tiQB: It is possible at this point to apply ZAPs to the loaded system by entering CP mode. All text is now in storage and the DISPLAY and STORE commands may be used to make changes. ~§tem A£!i2~: VSAMGEN issues a read to the terminal and waits for a response. ~ Action: If ZAPs are desired, enter CP mode. Make the desired changes, return to CMS READ via BEGIN command. Enter null line to cause the VSAMGEN to continue. 382R ENTER NUMBER OF TAPE FILES TO BE PROCESSED: jzplanation: VSAMGEN must know how many PTF tape files to scan for the VSAM and Access Method Services replacement modules. ~l§te! !cti2B: For DMSVIB, CMS abEnds with an abend code of X'104'. For DMSSET, RC = 40. For all other modules, Re 104. Execution of the command is terminated. The system status remains the same. User Action: -,:- Contact the system programmer, who must create a new copy of the named VSAM or Access Method Services system at an address that is high enough not to conflict with any virtual machine size permitted for VSAM users, or 2. The system vai ts for a US!I ActiQB: Enter a decimal number showing the number of tape files to be processed starting with current tape position. 383R APPLY 'filename'? ••• ENTER 'NO' OR EOE: ~~!~nation: The user has reguested selection of PTF replacement modules during VMFDOS execution. 170 The a Us~ Action: If you desire to temporarily halt the creation of the saved system, enter 'QUIT'; if 'GO' is entered, the saved system will be built. .§.I§!§! !£!iQn: response. Actio~: response. IBM VM/SP system Messages and Codes Enter CP mode and define a smaller virtual machine storage size £or this VSAM user so his . virtual storage is not overlaid by the named system, and then reload (via 1Pt) CMS/DOS. 402W DMSLER NOT IN CMSBAM SUPPORT NOT AVAILABLE !!B!~Bg~i2B: SEGMENT. ESERV The DMSLBR module, that simUlates the macros necessary to run the ESERV program, could not be found. DMS 2~£~em Actign: System operation continues but support for ESERV command execution is not available. Us~ Action: If you require the use of the ESERV command, contact your system support personnel. 403S filename SHARED RELOAD CfIlSDOS SEGMENT NOT AVAIlAELE reader, the printer, a tape drive, or the logical unit assigned to the specified OSor DOS-formatted disk. The 'nn' code indicates the nature of the error; it may be one of the following: Code Meaning --3-- An unknown error occurred. ~~~lanatig~: An OPEN has teen issued for a file that resides on an FE-512 DASD, but the CMSBAM shared segment has net been generated. 2~st~ Action: The OPEN is System statUS-remains the same. canceled. Actign: The CMSEAM shared segment must be generated and saved with the VSAMPP EXEC and the SET DOS ON command reissued. Us~~ 404S filename LOGIC MODULE 'segname' SHARED SEGMENT NOT FOUND IN Ex]1anatiQB: An OPEN has been issued for a file residing on an FE-512 DASD tut the appropriate logic could not be located. This indicates that the CMSEAM shared segment has been generated incorrectly. ~st~ Actio]!: The OPEN is System status remains the same. Code Meaning --1-- A line was too long. 5 An unknown error occurred. canceled. Us~~ !ctio~: Have the system pregrammer examine the CMSBAM linkage editor map for unresolved external references. The modules that are unresolved must be obtained from the DOS/VS PID tape and VSAMPP EXEC must be rerun to generate the CMSBAM shared segment. Code .H~gnillil fod~ Meani.llil A unit exception occurred. A wrong-length record was detected. A permanent I/O error occurred. -3-- 2 3 13 A permanent I/O error occurred. Syst~ Actio~: RC = 100 Execution of the command is terminated. User Action: Use the error code to determIne-and correct the possible cause of error. 412S CMSXGEN FAILED DUE TO SETKEY ERROR Errors to issue the SETKEY keys. g~lg.ngtio~: occurred while trying command to set storage RC = 100 Execution of the command is terminated. The system status remains the same. ~Y§~~ !ct~g~: 410S CONTROL PROGRAM ERROR INtICATION 'retcode' EXElanatio~: An unexpected error occurred while the Control Program was processing a request from CMS to find or load the specified saved system. 2~§!~~ Actig.n: For DMSVIB, CMS abends with abend code X'177'. For other modules, RC = 177. In both cases, 177 is the actual error code from the Control program, indicating that paging 1/0 errors have occurred. The QUERY SYSNAMES command displays the names of the saved segments for the CMS virtual machine. Any requested segment must have been saved via procedures documented in the VM/SP Planning and System Generation Guide. User !ctio~: Contact the installation system programmer for assistance. 411S {INPUTIOUTPUT} ERROR CODE 'nn' eN 'SYSxxx' Action: A message was issued by DMSSSK before this message was issued. USE the explanation and user action for the DMSSSK message to correct the error. ]§~£ 413S STORAGE NOT INITIALIZED FOR VSAM PROCESSING ~lanation: The program has issued a CDLOAD (SVC 65), but the DOS VSAM environment under CMS is not active. A CDLOAD requires VSAM storage initialization to have taken place, but this has not been done. RC = 104 The job is terminated. remains the same. ~1£~~~ !£!~g~: The system status User Action: Issue the CMS command SET DOS ON--with the VSAM option in order to initialize storage properly, and then reexecute the program. Explanation: An unrecoverable input or output error occurred while reading from or writing to SYSxxx. SYSxxx is the card Conversational Monitor System (eMS) Messages 171 D~S Q20E NSL EXIT FILENAME ~ISSING ~ The filename specified for Ex.B1~tion: user-written, nonstandard label processing routine must be the name of a TEXT or MODULE file. No file could be found that had a filetype of TEXT or MODULE with the specified name. .§.Ist~ ActiQ!!,: not executed. !£!!9B: Be sure the tape is positioned properly and that the correct tape is mounted. If necessary, reposition the tape and then reissue the job or command. OR INVALID The command or program Q23I is ~~laB~: This message occurs when you respond to message DMSTLB433R by requesting that a new volume label be written on a tape. An OS simulation SL tape has been requested with a specified positional parameter indicating the file is not be the first on the tape. Q§~ A£!i2B: Specify the name of a valid NSL exit routine and reissue the command. Q21E 'TAPn (cuu) , 'filename' 'TAPn (cuu) , POSITION PARA~ETER IGNORED. OUTPUT FILE WILL BE WBITTEN IMMEDIATELY APTER NEW VOL1 LABEL HDR1 LAEEI MISSING FOR ~~~ Explanation: A tape specified as standard label does not have a HDR1 label. Filename is dtfname for CMS/DOS or ddname fer OS simulation. The message will also occur for a tape that has HDR1 latels but is not positioned correctly for input label processing. Syst~ Acti.QB: The tape the record that was read executed. Action: The positional parameter is ignored and the new label file is written immediately after the new VOL1 label. 42QE 'TAPn (cuu) , NOT POSITIONED AT EOPl LABEl is positioned at when the HDR1 was 1ZRlanation: The CMS TAPESL macro was issued with the function EIN but the tape was not positioned at an EOP1 or EOVl label. For CMS/DOS, message DMSTLB435R is issued. ~yste~ Acti£D: No label is processed. The macro returns a code of 32 and the tape is left positioned to the same record it was positioned at when the macro was issued. For OS simulation, an OPEN error occurs. The TAPEMAC and TAPPDS commands are terminated without reading any tape data. The TAPESL 32. macro returns an error Us~ Acti.QB: Verify that the proper tape is mounted. Reply to message DMSTLB435R if issued. If the wrong tape is mounted, try again with the correct tape. If labels are not expected on the tape, respecify label type as BLP or LABOFF and try again. Q22E 'TAPN (cuu) , 'filename' POSITIONED WRONG FOR ~X]1anation: A tape was not positioned correctly for label processing to occur. For output tapes, an attempt was made to write a new label when tne tape was not positioned at an existing HDR1 label or tapemark. For CMS/DOS input tape, the message is issued when the file sequence number on the tape label is larger than tne one specified in the LABELDEF command. The filename is the symbolic name in the DTF~T for the file. For CMS, the filename is LABDEFid. For OS simulation, the filename is ddname. .§.Ist~ Acti.QB: An OS file is not opened. A C~S/DOS job is cancelled and the TAPESL macro gives an error return code of 32. 112 IBM V~/SP System Messages and Codes User Action: Space the tape so it is FosItionea-it the EOFl trailer label and reissue the macro or ignore the error if you do not want the tape trailer label processed. code of 425R 'TAPn (cuu) , BLOCK COUNT ERROR 'filename' ENTER 'IGNORE' OR 'CANCEL' POR ExplanatioD: The block count in an EOFl record does not match the number of blocks actually read. Filename is dtfname for CMS/DOS or ddname for OS simulation. For OS simulation, the message is only issued when you do not have a block count exit routine specified in the DCB EXIT list. Por the TAPESL macro the message is issued only when you have not specified an error return (by the ERROR=parameter) that is different from the normal return. ~y§!~~ ~B: The system waits for a reply. User Action: Enter 'IGNORE' to continue processing norma~ly or 'ERROR' to cancel the job in CMS/DOS, or to cause an atend with code 500 in either OS simulation or when processing the CMS TAPESL macro • DMS Q26R 'TAPn (cuu) , UNEXPIRED OR 'ERROR' FILE ENTER 'IGNORE' gxpla~: The system is trying to write over a HDR1 record on tape cuu that has an expiration date that has not yet expired. Syst~~ ActioB: response. The system waits for a User Action: Enter 'IGNORE' to write over exIStIng record and disregard the expiration date. Enter 'ERROR' to cancel the job in CKS/DOS or to prevent the file from being opened in OS simulation. the- If the type of label processing is BLP or IL, a tape mark is written after the last Iecord. If the file has nonstandard labels and a user exit has been specified, control is transferred to this nonstandard label routine. System Action: A tape mark is written after the last data record. If the file has nonstandard labels and a user exit has been specified, control is transferred to this nonstandard label routine. See message D!STLBQ281 for a description of tape positioning and user program action when this message is issued. Q§~~ Q27R 'TAPn (cuu) , EOV1 LABEL READ Explanation: While processing trailer labels for an input tape file, an EOV1 label was read instead of an EOF1 label. .§.l~ Acti.Q!!: None. !ill.2.n: No response is necessary. However, if you want to mount a new tape and continue reading the file, you must send a message to the operator requesting that a new tape be mounted. The data on the new tape must be processed as a new file by CKS. !!.§y Action: The operator must mount a new tape to continue the file. If pOSSible, the operator should reorganize the data so each file will fit on an individual tape. In a user routine, the output file should be closed. This will cause a tape mark to be written whether the label processing is BLP, NL, or LABOFF. The tape mark after the last record will allow the file to be read without error. Q30E 'TAPn (cuu) , LABELDEF FOR FILE 'filename' INFORMATION MISSING ~~~natio.n: Q281 'TAPn (cuu) , EOV1 LABEL WEITTEN !!planati2B: End-of-tape was encountered while writing an output file on a tape with IBM standard labels under CMS/DOS or OS simulation. This message is also issued when TAPESL is used to write an EOV1 label. §ystem !£llil!: are written end-of-tape. A tape mark and EOV1 label after detecting the For CMS/DOS, the job is then cancelled and the tape is rewound and unloaded. For OS simulation, the program abnormally terminates with a code 001 if you are using QSAK or if you use a CHECK macro in ESAM. If you are using BSA! with no CHECK macro, your program continues to try to write on the tape. The tape is always rewound and after this message is issued. Under eMS/DOS or CMS you must specify a LABELDEF statement for every labeled tape file. One was not fcund for DTFMT or labeldefid with the specified filename. The message may occur for OS simulation files if you have inadvertently cleared the FILEDEF or LABELDEP for the specified filename. §ystem Actio.n: The job is canceled for CMS/DOS, the file is not opened for OS simulation and the TAPESL macro returns an error code of 28. ~~ Action: specify a LABELDEF statement for the file and execute the job again. 431E 'TAPn (cuu) , VOL1 LABEL MISSING IAP!!~~: This message occurs when you request that a tape have its VOL1 label checked or displayed. The tape does not contain a VOL1 label as its first record. unloaded §l§te~ !£!i~: The TAPE command is terminated. User Action: The operator must mount a new tape to continue the file. If possible, reorganize the output data to fit on a single tape reel. For CMS/DOS input files, message DMSTLB435R is issued. Por OS input files, an OPEN error occurs. 4291 'TAPn (cuu)' EOT ON OUTPUT Explanation: End-of-tape was encountered while the system was writing a tape file with CMS/DOS or OS simUlation I/O macros. The tape file was not defined to have IBM standard labels. User Action: Be sure the operator has mounted-the correct tape. Respond to any further messages that are issued. If necessary, reissue the command or program. Conversational Monitor System (CMS) Messages 173 DMS 432E 'TAPn (cuu) , VOLID volid DOES NOT LABELDEF VOLID FOR 'filename' MATCH Ex~~: The volume serial number (volid) on a tape VOL1 label is not the same as the volume serial number specified on a LABELDEF or FILEDEF command. Filename is dtfname for CMS/DOS or ddname for os simulation. The volid displayed in the message is the one found on the tape label. Actio.!!: CMS/DOS DMSTLB435R is issued. ~st~l!! CMS commands being read. terminate For OS simulation, the file is not opened. User Action: Ee sure the LABELDEF statement for-the file is correct. If it is, the wrong tape may be mounted or it may be positioned at the wrong file. Reply to message DMSTLE435E if issued. message files, 435R ENTER 'IGNORE' or 'CANCEL' terminate without any For CMS TAPESL macro for input, code of 32 is returned. For OS simulation input not opened. CMS commands and TAPESL macro without reading any tape data. data Expla~io.!!: This message is never issued alone. It always follows another CMS/DOS message that identifies a tape label error. an error files, the file is For OS simulation or TAPESL output files, message DMSTLB433R is issued. This message gives the CMS/DOS user the choice of ignoring a label processing error and continuing the job or cancelling it. Syste]!! reply. Action: The system waits for a User !£!ion: Enter 'IGNORE' or 'CANCEL'. User Action: Be sure thE correct volume serial-number is specified on the command. If it is, the correct tape was not mounted. Ask the operator to mcunt the Froper tape. Reissue the command or program. 4361 'TAPn (cuu) , MISSING FOR 'ddname' USER STANDARD LABEL This message is issued when the OS simulation user reguest SUL tape label processing on a FILEDEF command. The user also has a user exit in the DCB exit list for the file identified by ddname. However, the tape did not contain a user UHL or UTL label. ~lE!~ng!io.!!: 433R ENTER 'WRITE' (volid) OR 'REJECT' Exllg,Bation: This message is issued when an output OPEN routine finds a tape has a VOL1 volid that does not match the one specified or if an output tape has been specified as SL and no VOL1 label is on it. The message is issued only in situations where a DOS/VS or OS/VS operating system allows a VOL1 label to be written. It is never issued unless either message DMSTLB431E or DMSTLB432E is also issued. ~Y§!~l!! A£~ion: The system waits for ~~f Us~ !£i!Q.!!: You may enter 'REJECT' to reject the tape or rewrite the VOL1 label on the tape by entering WRITE followed by a left parenthesis and, with no intervening blanks, a one- to six-character volume serial number to be written in the label. No owner field may be specified. To write a VOL1 label with an owner field you must use the WVOL1 function on the TAPE command. 'TAPn (cuu) , INPUT LABEL ERROR IN 'fieldname' FILE 'filename' FIELD Explanation: A field in a tape HDR1 label did not agree with the field specified on a LABELDEF command for the file. Filename is dtfname for CMS/DOS or ddname for OS simulation. 'fieldname' identifies the field causing the error. ~stem Action: For DMSTLB435R is issued. 114 Action: If a tape mark is read instead of the expected user standard label, the tafe is positioned at the record immediately after the tape mark. Otherwise, the tape is tackspaced so it is positioned at the record that was read when a user standard label was expected. a reply. 434E ~Y§!~ CMS/DOS, IBM VM/SP System Messages and Codes Action: None, if the tape file was not expected to contain a user label. If one was expected, halt the program execution and be sure the correct tape is mounted. 'TAPn (cuu) , NSL ROUTINE RETURNED CODE 'nnnnnn' FOR 'filename' ERROR ~lanation: This message is issued when you execute a nonstandard tape label processing routine that returned a nonzero return code of 'nnnnnn' in register 15. 'filename' is the ddname for the file that caused the code for OS simulation; for the TAPEMAC and TAPPDS commands, it is the id parameter specified by the user. System Action: The nonzero return code prevents an CS file frcm being opened or causes the TAPEMAC or TAPPDS commands to be any tape terminated without processing files. message Y£~f Action: Examine your NSL routine to be sure you wanted to return a nonzero code. DMS If you did, then you probably have the wrong tape mounted or you anticiFated this condition. SOOE UNABLE TO UNPACK FILE 'fn ft fm' condition was li.!E!anatioB: An error detected during the process of unpacking a file. 444E VOLUME 'label' IS NOT A DOS SYSRES !ct!£B: RC = 88 Execution of the command is terminated. ~ystem !!£!AnatigB: The disk specified by the mode operand of the SET DOS ON command is not a VSE/AF system residence volume. ActigB: RC = 32 Execution of the command is terminated. The system status remains the same. User Action: Contact your system personnel for assistance. support ~n.!! User Action: Reissue the command correct mode. 445W INVALID DATA IN SEQUENCE SEQUENCE CHECK 5011 nn LINES DELETED with the Exp1anatioB: The number of lines deleted as a result of a DELETE subcommand is displayed. FIELt, BYPASSING ExElanation: The sequence field on the file being loaded in not numeric. 502E nn LINES TO RECOVER ~y§!~ Actig~: The file continues to be loaded. ]~£!~~~!ioB: User Action: -roaded errors. as a result displayed. Check the file after it has for possible transmission been 495E THE 'module1' MODULE CAN CNIY EE EXECUTED EY THE 'module2' MODULE, IT CANNOT BE EXECUTED BY ITSELF 502W NO LINE TO RECOVER JZ£!sA!ti~: ~l£!~natiQ~: module1 can cnly be executed by module2, and cannot be invoked and executed by itself. Syst~! !£!!g~: Execution of module1 The number of lines recovered of a RECOVER subcommand is A RECOVER subcommand was issued, but the buffer that contains "recoverable" lines was empty_ is terminated. User Action: None. User Action: Do not iOdUle~Itself. attempt to execute 503E 496S READER FILE ALTERED TO DISK LOAD AS: 'fn ft fm'. DISK LOAD STOPPED! FILE HAS BEEN LEF~ IN YOUR READER ~RUNCATED j~£!gB~tion: The current line has exce€ded the truncation column, and the extra characters have been truncated. Explan~: Someone has sent you a file with an altered fileid. A file is not loaded when the last card of the reader file does not match the filename, filetype, and/or filemode of the first card in the file. The filename, filetype, filemode specified in the message is the file that would have been erased by the DISK LOAD. 2.U..1:n !ill.2!!: The file is reader. = 504E nn LINE(S) TRUNCATED ~.!£!~!!A!ion: RC 1 00 not loaded and is User Action: To avoid truncation of ;ubsequent-·-lines, change the trunca tioD setting by issuing a SET TRUNC subcommand. left in the SHIFT Lihes·wetetruncateddue to a subcommand~ Q§~ Action: Determine who sent you this altered file by issuing CP QUERY Reader. If you still want to load the file, use the READCARD command. Otherwise, to delete this file from your reader, use the CP PURGE command. Conversational Monitor System (eftS) Messages 115 DMS 505E NOT EXECUTED: THE TARGET LINE (nn) WITHIN THE LINES TO {MOVEICOPY} IS Explanation: The destination line for a move or copy operation fell within the block of lines to be moved or copied. System Acti~m: User Action: subcommand.- RC = 509W USE GET AND/OR PUT (D) UPDATE MODE TO MOVE LINES IN I!El§Bgtion: The MOVE subcommand was issued in update mode. .§.l§m Action: RC=3 1 Actio~: To move lines in update mode, use the GET or PUT (D) subcommand. ]§§~ Correct and z:eissue the 5101 AUTOSAVED AS 'fn ft fm'. 5061 nn LINES {MOVEDICOPIED} !!]lanation: The numbez: of lines that were moved or copied is displayed. !nl§!lS!i2!p As a result of a SET AUTOSAVE setting, the file was wz:itten to disk with the fileid that is displayed. The ~lli'§J!! !£!ioB: continues. Us~~ editing session Action: None. 507E NO PRESERVED DATA TO RESTOBE !X£lanation: A RESTORE subcommand was issued to restore the sEttings of XEDI~ variables but the PRESERVE subcommand had not previously been issued to save the settings of the variables. Acti.Q'!!: RC 3 subcommand is not executed. .2I~!! The RESTORE 511E STRING2 CONTAINS THAN STRING1 MORE ARBITRARY CHARACTERS jxpla'!!stion: In a CHANGE subcommand, the operand 'string2' contained more arbitrary chaz:acters than the operand 'string1' • SysteJ!! !~: RC=5 !£!ion: Correct the operand 'string2' and reissue the CHANGE subcommand. ~~~ Action: If you wish to alter XEDI~ variables temporarily, enter the PRESERVE subcommand, then change the XEDIT variables using the SET subcommand. Subsequently, enter the RESTORE subcommand to restore the variables to the values t~ey had when the PRESERVE subcommand was last issued. ~ 508E 'load' MUST BE THE PROFILE FIRST SUBCOMMAND IN THE EX]12~: During the execution of a XEDIT profile macro, a LOAD subcommand was detected that was not the first XEDIT subcommand in the macro. 2.Yst2 Acti.QB: RC=3 The XEDIT profile macro is partially executed. The system executes all EXEC 2 statements, CMS commands, and XEDIT subcommands in the macro until the LOAD subcommand is reached. It then ignores the LOAD subcommand and all subsequent subcommands. Upon detection of the first XEDIT subcommand, the editor automatically executed a LOAD subcommand that was used to invoke the profile macro. No moz:e than one LOAD command, either implicit or explicit, may be executed in one XEDIT macro call~ Action: Correct your XEDIT profile macro. Move the LOAD subcommand up so that it is the first XEDIT subcommand to be executed. 512E INVALID SUBSET COMMAND A CMS command that is not one of the CMS subset commands was issued, and the editor is not in the CMS shared segment (where any CMS command may be executed). A~£ls!lS!i.QB: §1§!§!! !£!i.Qn: RC=1 or 2 RC=1: The command was passed to CMS; the command was not a valid system editor subcommand. RC=2: The command was passed to CMS. The VM/SP editor did not attempt to decode the command. 513E UNKNOWN CP/CHS COMMAND A command was transmitted to CMS or to CP but was not recognized. ]aplanS!i~: ~I§~!! Action: RC=-3 reissue the E~R!sBS~: A CMS or CP command executed, and an error occurred. was Jl~ Acli~: Correct and ccmmand. ~§~ 51qE RBTURN CODE Inn' FROM 'command' The return code from the CMS or CP command is displayed in the message ~!.§J!! !~~: 176 IBM VM/SP System Messages and Codes Des User Action: conan '(1:--- Correct and reissue the A SET RECFM subcommand vas issued and the operand was not recognized. !xpla~atiQB: !£liQg: RC=5 The subcommand is not executed. ~stg Correct Acti.QJ!: sUbcommand. and V-FORMA~ Ieissue .!!§§!; Actio~: subcommand. the The line number specified in a GET subcommand was zero; or one of the following SET subcommand options was issued with an invalid line number: CURLINE, SCALE, TABLINE. Correct and reissue the FILE and 522I nn OCCURRENCES The number of occurrences of a string located by a count subcommand is displayed. &!~l~ion: ~ystem ~xecuted. Correct reissue the Explanation: A SET IRECL subcommand was issued with a logical recoId length that exceeds the maximum for V-format files, which is 65,536. Syst§m !£!iQB: RC=4 The subcommand is not and llRl~tion: !!§§!; Action: sUbcommand. 516E LRECL TOO LARGE FOR Correct 521E INVALID LINE NUMBER 515E RECFM MUST BE {FIVIFPIVP} Us§!: ActiQ~: subcommand. .!!~~ reissue Action: None. the 5231 TYPEWRITER MODE 511r nn OCCURRENCE(S) CHANGED ON nn LINE(S) gZ~!~!io~: An ALTER maCIO or a CHANGE subcommand caused Inn' lines to te changed. !Z~!~BAtion: subcommand terminal. TERMINAL A SET issued from was 'IIPEiRI'IER a display J!§y ActiQJl: None. 518E nn OCCURRENCE(S) CHANGED LINE(S) TRUNCATED. ON nn IINE(S); nn 524W NONDISP CHARACTER RESET '10 BLANK A SET APL ON or SE~ TEXT ON subcommand was in effect, and a SET NONDISP SUbcommand was issued defining an APL or TEXT character as the non-displayable character. When a SET APL OFF or SET TEX'I OPF was issued subseguently, the editor automatically reset the non-displayable character to a blank. !!~!~g: ExE!anatiQJl: A CHANGE subcommand caused Inn' lines to be changed; as a result, 'nn' lines were truncated. Us~!: ActiQB: None. 519E IRECL MUST BE LOWER THAN WID'IH (nn) A SET IRECL sutcommand specified a logical recoId length greater than the WIDTH option in the XEDIT command. !zE!s~: PFn subcommand was A SET issued, and 'n' was either zero or greater than 24. . System ActiQ!!: RC=5 The subcommand is not executed. User Action: subcomiDaiid."- Correct and 525E INVALID PFKEY NUMBER j~lanation: J:eissue the 520E INVALID OPERAND : operand Explanation: A subcommand was issued either with an invalid operand or with too many operands. User Action: SUiiCommand. Correct and reissue the 526E OPTION 'option' VALID IN DISPLAY MODE ONLY A SET subcommand option valid only in display mode was issued from a typewriter terminal or a display terminal l~lanatio~: system Acti.Q.!p RC=5 The subcommand is not executed. Conversational Monitor System (CMS) Messages 177 DMS being used in typewriter mode. The following SET subcommand options are valid only in display mode: APL CURLINE MASK NONDISP NULL NUMBER 531E DISK IS FULL. SET NEW SOME DISK SPACE, jxplanation: The during execution subcommand. PFn PREFIX RESERVED SCALE SCREEN TAELINE TEX'! llLEMODE OR outp~t of a Cl.!AR full SAVE disk became FILE or .allj:~ Acti.Q'!!: Re=13 The editing session continues. Action: Specify a new filemode MODE) or make more room on the disk .. (SET .Y~ 532E DISK IS FULL; AUTOSAVE FAILED j.!.p.!~tio,!!: The output disk became during an automatic save operation. 521E INVALID COLUMN NUMBER A!£!gnation: A CURSOR subcommand was issued with an invalid column number. Correct User Action: subcommand:-- and reissue full ~tem Acti~: RC=13 The editing session continues. User Action: Use the SET AU~OSAVE sUbcommandto specify a new filemodE, or make more room on the disk. the 533E LINE 'linenum' IS NOT RESERVED 528E INVALID RANGE TARGEI2 (L1NE nn) PRECEDES TARGET1 (LINE nn) ExE1gnatio~: specified in reversed. The a SET !lli~lli.!!: A SET RESERVED nn OFF subcommand was issued, and Inn' indicates a line that is not currently reserved. 'target' operands RANGE subcommand were Syst~.!!! Acti.Q1!: RC=4 The subcommand is not executed. Actign: RC=5 The subcommand is not executed. ~stem User Action: subcommand.- Correct and Q.§~ reissue Acj:ion: Reissue the subcommand .. the 534E TOO MANY LOGICAL SCREENS DEFINED 529B SUBCOMMAND IS ONLY (DISPLAYIEDITING] MODE VALID ]z'p'!anatio,!!: A SET SCREEN subcommand was issued, and In' specified too many logical screens for the physical screen size. IN Ex£!gnation: A subcommand was issued that is valid only in display or editing mode. The following subcommands are valid only in display or editing mode: ADD BACKWARD CURSOR FORWARD JOIN CURSOR MODIFY POWERINP RESET SCHANGE SOS SPLIT CURSOR ~Y§j:~ Action: RC=4 The subcommand is not User Action: subcommand:-- executed~ Correct and reissue the 535E INVALID PARMS FOR RENUM ~~'p~ion: A RENUK subcommand was issued, and either the 'startno' or 'incr' operand was specified as zero. ~1~! ActiQ~: RC=5 The subcommand is not executed. USll Action: None. User Action: subcommand:- Correct and reiSSUe the 5301 nn FItE(S) IN STORAGE. Ex.E1anation: executed. ~ste.!!! Us~~ 118 A QUERY RING subcommand Acti.Q1!! None. Action: None. IBM VM/SP System Messages and Codes was 536E NUMBER OF SIZE LINES EXCEEnS P~YSICAL SCREEN !nillA!ill: A 'SET SCREEN SIZE' subcommand was issued, and 'n' specified a number of lines greater than thE ph'ysic::al screen size. DMS 542E NO SUCH SUBCOMMAND : name Systit!!! Acti.Q.!!: RC=5 The subcommand is not executed. £~!g~tion: User Actio.!!: subcommand. Correct and reissue the A subcommand not recognized by the editor was issued. ~yste~ 537E EACH LOGICAL SCREEN MUST CONTAIN AT LEAST 5 LINES Ex~nati.Q.!!: A 'SET SCREEN SIZE' subcommand was issued, and 'n1 ••• nn' would cause any logical screen to have fewer than five lines. Action: RC=-1 User Action: If the name you entered was a macro name, verify that the macro resides on one of your accessed disks. 543E INVALID NUMBER : xxxxxxxx A subcommand was entered that required a numeric operand, and an alphabetic operand was specified instead, or the number was too large. If the EXECUTE subcommand was issued with a negative number, this message is generated. The EXECUTE subcommand only accepts numbers greater than or egual to zero. ~lanation: ~st~ ActiQ.!!: RC=4 The subcommand is not executed. Us~ Actio.!!: subcomman d. Correct and reissue the 538E NO NAME DEFINED A 'QUERY POINT *' subcommand was issued, but no symbolic names have been defined. l~£1anation: User Action: subcommand. Correct and reissue the 544E INVALID HEX DATA : XXXXXXXX £~Elg.!!s!ion: The subcommand SET HEX ON is in effect, and characters that did not represent valid hexadecimal notation (OO-FF) were entered in a subcommand. 539E NAMED LINE NOT FOUND EXE!~Q.!!: A 'SET POINT' subcommand was issued to delete a specified symbolic name, and the name was not located. lli.:!:g Action: RC=-5 User Action: subcommand:- Us~ Correct and reissue the Actio!!,: None. 545E MISSING OPERAND(S) Explanatio.!!: A subcommand was entered without the required number of operand(s). 540E NAME ALREADY DEFINED ON LINE 'nn' EXE!~Q.!!: A 'SET PCINT' subcommand was issued to define a symbolic name, and the -specified name was already assigned to another line. ~~te~ Action: RC=-5 The subcommand is not executed. User Action: subcommand. Correct and reissue the User Action: Issue a "SET POINT .symbol OFF' subcommand to delete the previous I 546E TARGET NOT FOUND assignment, or select a unique name and reissue the subcommand. ~lanation: A subcommand was issued with a target operand specified as a string expression or line name that was not 541E INVALID NAME located. Explanation: A 'SET POINT' subcommand was issued, and the specified name either exceeded eight characters or was not preceded by a period (.). ~.§ telD ~!~~ ActiQ.!!: RC=2 The subcommand is not executed. User Action: SlibCommand. Correct and reissue the illi.Q.!!: RC= 5 User Action: subcomiiii'ii'd."- Correct and reissue the 547E SYNONYM DEFINITION INCOMELETE ~~E!gnatiQ'!!: A 'SET SYNONYM' subcommand was issued without the required number of operands. Conversational Monitor System (CMS) Messages 179 DftS Syst~ Actism: RC=5 The subcommand is not executed. User Action: subcommand.- Correct and 552E NO SYNONYM CURRENTLY D!F1NED reissue the Explanation: A 'QUERY SYNONYM *' subcommand was issued, and no synonyms are currently defined. 548E INVALID SYNONYft OPERAND : operand A 'SET SYNONYM' subcommand was issued with an invalid 'fermat' operand. User Action: None. ~~£!anation: 5531 EDITING FILE: fn ft fm .§'yst2 A£tism: RC=5 The subcommand is not executed. User Action: Correct the 'format' operand and-reissue the subcommand. Valid ways to specify 'format' are: &, &/, &., and &*. 549E SYNONYM ABBREVIATION TOO LARGE Explanation: This message is displayed on a typewriter terminal or a display terminal used in typewriter mode, when one of the following occurred: 1. An XEDIT command was issued. 2. ftultiple files are being edited, and a QUIT or FILE subcommand was issued. The fileid displayed is the new current file. ExplaBAti£B: A 'SET SYNONYM' subcommand was issued and 'n' (minimum number of characters) was larger than the word itself. Syst~! ActiQ~: RC=5 The subcommand is not executed. User Action: s\ibcommand."- Correct and reissue 'the 554E NO STORAGE AVAILABLE No more storage is available, and one of the following subcommands, which require additional virtual storage, was issued: PRESERVE, PUT, SORT, SAVE, or FILE (with SET PACK ON), SET POINT, SET SYNONYM, or XEDIT • ~!E!!.n!!ion: 550E TOO MANY OPERANDS IN SYNONYM DEFINITION EXElanatism: A 'SET SYNONYM' subcommand was issued with more than 64 operands. .liYstem Actism: RC=5 The subcommand is not executed. User Actio.!!: subcommand. Correct and ~!~ reissue the !£tion: RC=3 The subcommand is not executed. User Action: Increase the storage size of virtual machine by issuing a CP DEFINE STORAGE subcommand. your 550W DATE/TIME DATA NOT PRESENT FOR FILE 'fn ft' Ex~la~tion: This message is issued when using the OLDDATE optien of DISK LOAD and the time of the file being loaded is blank. .§'ystem Acti£B: The file new date and time. is loaded with a 555E FILE 'fn ft fm' ALREADY IN STORAGE jxplanation: A load subcommand was issued for a file that is already in the ring of files in storage • A duplicate copy of the file that was requested will not be loaded into storage. '§Y§1~m !cti~: 5511 STRING 'string' FOUND. SELECTIVE CHANGE.] [---PFnn SET FOR An SCHANGE macro was executed. If a CLOCATE subcommand was typed in the command line, the first part of the message is displayed. If a CHANGE subcommand was typed in the command line, the message alsc displays which PF key must be pressed to perform the change. ExplanatiQ~: Q~ Ac~: None. 555W FILE 'fn ft fm' ALREADY IN STORAGE An XEDIT subcommand was issued for a file that is already in the ring of files in storage, or a SET FNAME, SET FMODE, or SET FTYPE subcommand was issued whose operands are the same as those of a file already in storage • Explanatio~: .§.I.§tem Actism: None. Action: If the error resulted from an XEDIT subcommand, the file that was requested becomes the current file. Any ~.Y§tem Us~ ~: 180 None. IBM VM/SP System Messages and Codes Df!S 561E CURSOR IS NOT ON A VALID DATA FIELD options specified are ignored. Us~ 556S 1xpla~!ion: Action: None. UNDEFINED MESSAGE loc.) (DMSXER CALLED AT hex Explanation: The editor attempted to display a message that is not in tMSXER. a!stem Acti~: A command was issued with the CURSOR or SCHANGE option, and the cursor was not on a file line, or the cursor or column specified was outside the current 2ones. The ayste!l! Action: executed. subcommand Use~ Action: Reposition reissue the subcommand. None. Q§~ Actio~: Contact your system personnel for assistance. the is not cursor and support 562E NO LINE(S) SAVED BY PUT(D) SUBCOMMAND 557S NO MORE STORAGE TO INSERT LINES n.Planation: Storage was exhausted during the execution of one of the following subcommands: ADD, COPY, tUPLICATE, GE~ INPUT, SPLIT, and the following ~refix subcommands: A, C, E,". §lgn Acti,Q!!: RC=4 The subcommand stops executing when nc more storage is available. ~ Action: Increase the storage size of your virtual machine by issuing a CP DEFINE STORAGE subcommand, or release all unnecessary disks. jxplanation: A GET subcommand was issued, but no lines(s) had been stored by a PUT or PUTD subcommand. User Action: None. 563W RECORDS TRUNCATED 11R1anatiog: A GET subcommand was executed, and one or more of the inserted lines was truncated. J!~ 558E WRONG FILE FORMAT FOR ExE!~tion: A SET SERIAL subcommand was issued, and the file has a variable record format. Only files with a fixed record format can be serialized. S!st~ Action: None. SERIALIZA~ION 564 W EOF BEACHED !lE!sBs!ioB: A GET subcommand was executed, and lines were inserted up to the end of the file. !£1iQg: RC=5 User Action: You can issue a SET RECFM F SUbCommana-to change the record format of the file. (See also message 560E.) 565W EOF REACHED: RECORDS TRUNCATED 559W WARNING FILE IS EMPTY !lE!!B~tion: Explanation: A subcommand was the file contains no lines. ~~ issued, but A GET subcommand was executed, and lines were inserted up to the end of the file. However, one or more lines was truncated. Action: None. System J!§~ Acti2~: RC=3 !£tion: None. 560W NOT ENOUGH SPACE TRUNC AND LRECL FOB SERIALIZATION EETWEEN 569E NO 'CHANGE' SPECIFIED Explanation: A SET SERIAL subcommand was issued, and there is not enough room to insert the serial number. ayste!l! ill!srn: executed. The subcommand is not User Action: Issue a SET TRUNC subcommand so-ihat at least eight characters separate the truncation column and the logical record length. OR , CLOCATE' SUBCOMMAND jlElanation: The PF key assigned to the SeRANGE macro was pressed, but no 'CBANGE' or 'CLOCATE' subcommand has been typed in the command line. Systn Actio~: RC=5 The macro is not executed. J!§.!~ ,!£tion: Type a 'CHANGE' or 'CICCATE' subcommand in the command line and then Conversational Monitor System (CMS) Messages 181 DMS press the PF key assigned to SCHANGE. specified were one of the follcwing: non-numeric, zero, not in ascending order. ~ystem 5711 CREATING NEW FILE: Action: RC=5 The subcommand is not eXEcuted. Ex~!~ngtiog: An XEDlt command or one of the following XEDIT subcommands was executed: XEDIT, PUT, or PUTD. the fileid specified a file that did not exist on one of your accessed disks. User Action: SUbcommand. 576E Q§§~ and reissUE the {TOTAL VERIFY WIDTH EXCEEDS SCREEN SIZE (nn) I TOTAL OFFSET EXCEEDS LRECL (nn)} ]~l~!iQ~: Action: None. 572E TERMINAL ERROR. FORCED CASE UPPERCASE. ~z£l~natiQg: editor stack. Correct An error occurred when the was reading from the CMS console 2~st§~ AC!~Q~: A 'SET CASE UPPERCASE' subcommand is executed, and the editor attempts to read the data again. A SET VERIFY subcommand was issued, and the total width of the 'startcol' and 'endcol' operands is greater than the screen size; or a LEFT or RIGHT SUbcommand was issued, and the total value of tn' (when added to the value of In' specified in previous LEFT or RIGHT subcommands, if any) exceeds thE logical record length of the file. For JOIN or SPLIT, the cursor is outside the current zones. ~Y§!~ A£tio~: ActiQg: If the read was successful, you can reissue the SEt CASE subcommand if desired. Otherwise, contact your system support personnel for assistance. Us£~ 2~§!~ Correct User Action: subcomiiiand:- 577E FILE HAS BEEN CHANGED. ANYWAY 5731 INPUT MODE: Ex£lanatiog: executed. RC=5 The subcommand is not executed. An INPUt Act~Q~: The editor and enters input mode. subcommand and reissue USE QQUIT the TC QUIT was leaves edit mode Explanation: A QUIT or CANCEL subccmmand has been issued, and a file has been changed during the editing session. Syst£~ User Action: You can enter new lines into the-file, or enter a null line to return to edit mode. 574E CHANGE NOT VALID {WITH CLOCATEIAFTER CURSOR MOVEMENT} Ex£1~nation: Action: RC=12 the subcommand is not eXEcuted. User Action: Issue a 'QQUIT' subcommand if yoU-do--not wish to saVE the changes made during the editing session. Issue a 'FIlE' subcommand if you want the changed file to be written to disk. One of the following cccurred: 579R RECORDS WILL BE TRUNCATED TO (YES/NO) ?: 1. 2. An SCHANGE macro was executed with a CLOCATE subcommand typed in the command line. Then, a PF key assigned to a CHANGE subcommand was pressed. The PF key assigned to an SCHANGE macro was pressed, and a CHANGE subcommand is typed in the command line. The cursor was moved, and then the PF key set for the selective change was pressed. 2~§!§m ActiQg: The change is not made. nne CONTINUE Ex~lanation: A PUT (D) subcommand has been issued, and the existing file in which you wish to insert a line(s) has a logical record length smaller than the line(s) you wish to insert. Syst~ Actio~: The reply determines whether or not the subcommand is executed. Enter lines US§1; Action: 'YES', the inserted. 'YES' or 'NO'. are truncated If and 5aow PUT NOT EXECUTED 575E INVALID {JOINISPLITliAESIVERIFYIZONE} COLUMNS DEFINED ~lanatiQB: the 182 The subcommand displayed in message was issued, and the columns IBM VM/SP System Messages and Codes ]]~~ion: A 'NO' reply to was entered. ~lli~ ActiQ.!: None. message 579B DMS issued to change the screen string will be located. so that the 5825 EDITOB ABEND 5871 XEDI'!: I!E~an!tion: The editor has failed tecause: an error occurred while the editor was reading from the CMS console stack, or the editor was unable to allocate a saVE area. aIste; !£!ig~: a):)nor1l\ally. The system is Explanation: This message is displayed as a result of one of the following: • you return to EDIT mode from INPUT mode • you invoke XEDIT and PROFILE macro • you enter a null terminal terminated you don't have a Q§!I Action: Issue the XEDIT command again. If the problem persists, system support personnel. contact your line from a typewriter 5831 EOF: !!]!9~tion: On a typewriter terminal or a display terminal used in typewriter mode, the line pOinter has moved to the null END OF FILE line. mm !£.ti.2Jl: :!L§.u 588E PREFIX SUBCOMMAND WAITING ••• £~la~!io]: The status area displays 'COPY/MOVE PENDING' or 'BLOCK INCOMPLETE' as a result of the prefix subcommands, and a subcommand that adds or deletes lines was entered from the command line. Non e. Asll.2!t: Non e. 58IJI TOP: ay§!gm !£tiQ~: RC=8 The subcommand is not executed. lJ]laDS!ion: On a typewriter terminal or a display terminal used in typewriter mode, th. ldne pointer has moved to the Dull TOP OF FILE line. User Action: You can issue a RESET subcommand to remove the pending frefix subcommands, or you can complete the execution of the pending prefix subccmmands and then reissue the subcommand from the command line. 589E MISSING FILEDEF FOR DDNAME ddname S85E NO tINE (5) ,CHANGED command or For XEDI!, a subcommand was issu~d for a file that resides on an OS disk, but no FILEDEl command has be.en issued._ ~lBl~tion: llplanatiop: A CHANGE or ALTEE subcommand .asiSsued~ and the string to be changed oralter~d was not located, or an attempt waS made .to e:xecutea change in the null TOPOl FILE or END OF FILE line. Q§~Actio]: For NUCXLOAD a FILEDEF commmand identifying the load library must be issued prior to calling NUCXLOAD. . ~y§!gm!£1i2]: RC=32 The subcommand is not executed. None. 5861 NOT FOUND {ON SCREEN} l!E..J&nation: A FIND, FINDUP, NFIND, NFINnup subcommand was issued, and speCified'text'operand is not found. 5CHANGEma.cro was invoked, the CHANGE C:LOCATE subcommand was issued, and specified. 's·tring' (first operand CHANGE and only operand for CLOCATE) is found within the scr~en width. rum !£lign: or the The or the for not Us,!!! .!£!iQn: The System Product Editor uses the data definition name 'SYSIN' to read the 05 data set. Therefore, you mUst issue a FILEDEFcommand with 'SYSIN. specified as the 'ddname' before issuing the XEDIT command or subcommand~ Use CMS subset to enter the FILEDEF comm~nd. For NUCXLOAD, if you are loading a module from a CMS load libr~ry, issue a FILEDEF command identifying the load library. RC=2 ]§er Actio]: For SCEANGE macro and the CHANGE or CLOCATE subcommand, if the 'string' not found is outside the screen width, the BIGHT or LEFT subcommand can be 590E DATA SET TOO LARGE ~~!~ation: An XEDIT com~and or subcommand was issued for an OS data set that is too large for your virtual storage size. Conversational Monitor System (CMS) Messages 183 DMS Syst~ Actis;m: RC=BB The command is not executed. User Action: Use the CP ccmmand DEFINE to virtual storage size, and reissue the XEDIT command or subcommand. Initialize CMS again. increase-~he applied ]§!! j£j:ion: Verify that all the updates include serialization. 601R ENTER SPECIFICATION LIST: 591E OPEN ERROR ON SYSIN Expla~tion: An XEDIT command or subcommand was issued for a data set not supported by CMS. This message usuallj follows message DMSSOP036E. Acti.QB: RC=32 The subcommand is not executed. 596S Acti.QB: Refer to message DMSSOP036E. THIS MODULE EDITOR MUST BE CALLED 2l§!~! WITHIN THE Acti2~: system waits for a !£tio!: Enter the specification list • 602R ENTER TRANSLATION LIST: ~!E!g~!i2!: The translation list that is to be entered in conjunction with the TRANS option is requested. EXElanatign: An attempt was made to execute DMSXMS or DMSXPO from CMS. ~~ System Actign: RC=B8 ~ ~: Us~ The response. ]§~ .§ll!~ ~~ lnlanatio!: The specification list that is to be entered in conjunction with the SPECS option is requested. !£tio~: The system waits for a response. Enter the translation list. Action: None. 597E UNABLE CARDS TO MERGE UPDATES CCNTAINING './S' 603R FORMAT WILL 'mode (cuu) '. (IESINO) : ERASE ALI FILES DO YOU WISH TO ON DISR CONTINUE? ~!El!~!io!: ]zElanation: An XEDIT command has been issued with a 'MERGE' and 'CTI' option specified, and one of the updates in the control file contains a './S' card(s). .§lltem !ctiQR: RC=32 The command is not executed. User Action: Remove the reIssue the command. This message is a reminder that the formatting process erases existing files. 2ystem Action: response • ]§~f The system waits for a AE!ion: Enter "yes" or "no". 'flERGE' option and 59BS UNABLE TO BUILD UPDATE FILE DESTROYED 604R ENTER SORT FIELDS: INTERNAL LIST JZElanation: The command requires a list of sort fields on which to perform a sort. 21§!~ A FILE or SAVE subcommand has been issued, and the editor was unable to build the update file. Ex~nati.QB: 2yste~ Acti2B: RC=7 The command is not executed. User Actio~: Call your personnel for assistance. system Actio!: response. The system waits for a ~f Acti£!: Enter pairs of numbers, separated by a blank, defining the starting and ending character ~ositions of sert fields within the records. support 60SR ENTER DISK LABEL: ~!Rl!~!i2!: 599S UNABLE TO BUILD UPDATE FILE : SERIALIZATION DESTROYED You are requested to enter a label for the disk being formatted. The label will be written on the disk at cylinder 0, track 0, record 3. ]~Elg~tion: A FILE or SAVE subcommand has been issued and the editor was unable to build the update file because the serialization field. contains a non-numeric character. This situation may have been the result of a previous update that did not include serialization. 1B4 IBM VM/SP System Messages and Codes 2l§!~! Actig!: response. ]§~f The system waits for a Action: Enter a one- to six-character label for the disk. If you enter less than six Characters, the label is left-justified and padded with blanks. If you enter a null line, the system displays the message DtlS DISK REMAINS UNCHANGED. 606R SYSTEM DISK ADDRESS If you enter lIIessage = cuu ~st~~ Actio~: The system waits for a response. If you enter an invalid device address, the message DMSINI079E INVALID DEVICE ADDRESS REENTER is issued. Message DMSINI606R is reissued, and you may enter a valid device address. If you enter a null line, 190 is assumed to be the system disk address. Once the system disk address entered accepted, message DMSINI615R is issued. User Action: Enter a valid iiUll line. invalid device address, DMSINI079E INVALID DEVICE ADDRESS REENTER Explanatio!!: "cuu" designates the device address of the system disk (S-disk). On this disk CMS expects to find all CMS system information and programs not contained within the CMS nucleus, such as the disk-resident command modules. If the CMS nucleus is written on this disk, then cuu is also the IPL devicE address. Or-a an is device address is issued. Message DMSINI608R is reissued and you may enter a valid device address. IPL device designated is not If the currently defined, is not in read/write status, or is an unsupported device type, message DMSINI082E IPL DEVICE ERROR - REENTER is issued. Message DMSINI608R is then xeissued. At this time, you may enter CP mode by signaling attention, and determine the status of the designated device by entering the CP command QUERY VIRTUAL cuu Tben take the corrective action necessary to define the device for your virtual machine or to access it in read/write status. Reenter CMS mode by issuing the CP command BEGIN You must then reenter the device address. Once the IPL device address is message DMSINI609R is issued. 607R REWRITE THE NUCLEUS? (YESINO) Explanation: Your response to this message determines whether or not a copy of the CMS nucleus is written onto disk. ~Y§!~ !ctiQ!!: response. The system waits for Use! Action: Enter a valid or a iiUIlIine. a 609R NUCLEUS {CYLIELK} ADDRESS User Action: Enter either "yes" or "no." llyouenter "no" a copy of the CMS nucleus is not written onto disk. The remaining questions in generating a new CMS nucleus are skipped and control is passed to the CMS initialization routine. If you enter "yes", message issued. If you fail to enter the message DMSINI608R is either "yes" or "no", DMSINI081E INVALID REPLY. - ANSWER OR "NO" "YE~" is issued. Message DMSINI607R is reissued and you may enter a valid response. accepted, device address = nnn l!.pl~Mj;ion: "nnn" designates the cylinder address or FB-512 block number (on the device entered in response to message DMSINI608R) on which the eMS nucleus is to be written. nnn must te between 001 and m-l where ~ equals the number of cylinders or blocks on the disk, the cylinders or blocks on a disk being numbered from 0 to !. nnn must be entered in decimal. Por an FB-512 device, the block Dumber must be a multiple of 256 and 256 blocks must be available at that location to form an FE-512 extent. §l§!!! Ac!i~: response. The system waits for a If you do not enter a valid decimal cylinder or block number, the message 608R IPL DEVICE ADDRESS = cuu Explanation: "cuu" designates the device address on which the CMS nucleus is to be written. If the system disk and the IPL device are to be the same, you need o~ly enter a null line. ~stem Acti~~: response. The system waits for a DMSINI080E INVALID {CYLIBLK} NUMBER REENTER is issued, message DMSINI609R is reissued, and you may enter a valid cylinder or FE-512 block number. If the cylinder or FB-512 block(s) specified is not greater than the numter Conversational Monitor System (CftS) Messages 185 DMS already in use on the device (as indicated in the file directory), the message DMSINI083E NUCLEUS {CYLIBLK} SPECIFICATION UNACCEPTABLE, ERROR 'X' is issued. Message DMSINI609R is reissued. You may respond with a larger cylinder or block number, or IFl the CMS system and format the specified IPL device with the RECOMP opti,on. Once the nucleus cylinder or block address is accepted, message DMSINI610R is issued. User Action: address-.--- Enter a valid cylinder and hh.mm is the hour nucleus was created. Syst!~ !£ti.QB: response. The system User Action: Enter version Information or a null line. 612R INSTALLATION HEADING the eMS and minute waits for a identification = Explgnation: Sixty-four bytes of information, including blanks, can be entered to serve as an installation standard heading at the beginning of each output file. The default heading (specified by a null line) is: 610R ALSO IFL {CYLIBLK} 01 (YESINO) CONVERSATIONAL MONITOR SYSTEM ~!£lgnation: The initial 1FL text is always written on the same cylinder or FB-S12 block as the CMS nucleus, that is, the cylinder or FB-512 extent designated in response to message DMSINI609R. (The initial IPL text is a bootstrap program that reads in the nucleus from the designated cylinder or block.) If it is not also written on cylinder or tleck 0, you must ente,r the cylinder or block number whenever an IPL is issued for the system being generated. For more information, see the IPL comm.and in the .IHLSP fg f.Q~'!!.9 ~fe~~ !.Q~ Q~~Al ]~~!~. .21.§.tg,!! !£.ti.Q'!!: If you do not en ter "yes" or "no", the message DMSINI081E INVALID REPlY - ANSWER "YES" OR "NO" .21'§!!~ Acti.Q'!!: response. If you enter "yes", the initial IPL text is written on cylinder or block 0 as well as on the cylinder or block designated in response tomeS.Siage DMSINI609R. If you enter "no" the initial IFL text is written only on the cylinder or block designated ' i n response to message DMSlNI609R. If you enter either "yes" or "no", message DMSINI611B is issued. 611R VERSlO. IDENTIFICATION = lZ£lanati.Q.!l: Thirty-two tytes of information, including tlanks, can be entered to specifically identify the version and level of CMS; this information is displayed or printed out when an IPL CMS is executed. The default identification (specified by a carriage return) is: VM/SP CMS - mm/dd/IY hh:mm where mm/dd/yy is the 186 month, day, and year IBM VM/SF System MEssages and Codes system waits for a Ac!io~: Enter up to 64 characters of identifying information, or a null line. ]E~ 615R Y - DISK ADDRESS = cuu .!!,plaBAti,QB: "cuu" designates the device address of the system disk extension (Y-disk). On this disk, CMS expects to find all CMS system information and programs not contained within the CMS nucleus and not OD the S-disk, such as disk-resident command modules. If the CMS nucleus is written on this disk, then cuu is also the IPL device address. (It is not required that you have a Y-disk.) 21§!~~ is issued. Message DMSINI610R is reissued and you may enter a valid response. The !cti2B= response. The system waits for a If you enter an invalid device address, the message DSMINI079B INVALID DEVICE ADDRESS REENTER is issued. Message DMSINI615R is reissued, and you may enter a valid device address. If you enter a null line, "19E" is assumed to be the system disk extension address~ If you do not want a Y-disk, then do not have a disk 19B in your directory entry, and enter a null line. Once the system disk extension address is accepted, message DM5INI607R is issued. User Action: Enter a anuilline. valid disk address or 616W 'na.e' DOES NOT EXIST ]!£lanatio~: The named does not exist. ~!~ y.§!~ nucleus extension !ctiOB= RC=28 jctioB: Check the spelling of 'name'. DflS 617E ERROR CODE nn FROM DMSFRE~ WHILE UNLOADING 'module name' MODULE Ex~!~!i~: An invalid DMSFRET request was made while unloading 'module name' module. An error was made in calling a nucleus extension or the created nucleus extension was damaged in some way. NUCXDROP uses the BYTES associated with the module name as the number of bytes to free starting at the ORIGIN address. One or both of these fields have been destroyed. The error code indicates the type of error that occurred. The error code meanings are: £Qde Meaning 5 The number of doublewords was 0 or negative. 6 7 specified The block of storage being released was never allocated by DMSFREE. The address given for the block being released is not double word aligned. !£ti.Q!!: RC = 3 The system makes no further release the storage block. .2.Ist~ attempt to 620E RTABLE ERROR ON LINE 'nnn' - {NON-NUMERIC VALUE SPECIPIEDIINCORRECT NUMBER OF PARAMETERSIMISALIGNED FIELDIINVALID PROP USE RID} Explanation: An invalid character was specified for a numeric value in the routing table, or an incorrect number of parameters was specified on the parameter record in the routing table, or field in an RTABLE entry starts after the correct column, or PROP userid in RTABLE is not the userid of the virtual machine in which PROP is executing. Syst~.!!! Action: Execution continues with the current routing table. Por PROP, execution continues if PROP is already running, execution stops of PROP is being started. User Action: Correct the invalid table entries and re-execute the command or restart the PROP. routing LCAD~BL 621E BAD PLIST: (The multiple variations of this message are explained below. The 'system Action' in each case is: RC=24 Execution is terminated.) Q§~; Actio!!: NUCXMAP may be used after defining a nucleus extension to display the origin and length of the loaded program. If these are incorrect, the call defining the nucleus extension was in error. If they are correct, then some program violated the SCBLOCK defining the nucleus extension after NUCXMAP displayed it. This program should be identified and corrected. EXECIO MUST EXTENSION BE INVOKED AS A NUCLEUS invoked by an EXECIO was assembler program and passed the inccrrect parameter list for a nucleus extension call. 1~1~!ion: User Action: Make sure you are passing a parameter-list for a nucleus extension. 618E NUCEXT FAILED Explanation: An attempt to establish a function as a CMS nucleus extension failed because of a system error, or because the level of CMS does not support extensions to its nucleus. = Syst~ Acti,QB: RC 13 ~nn' is NUCEXT's return or RC = 4nn where code to the calling module. Execution of the command that called NUCEXT termina tes. DISK 'argument' ARGUMENT IS MISSING Explanation: The missing 'argument' is FILENAME or FILETYPE. These are reguired arguments when DISKR or DISKW operations are specified. User Action: Reissue the command disk argument. with the INPUT FILE 'fileid' DOES NOT EXIST Us~ Action: Verify that the level of CMS being used contains support for nucleus extensions; take action indicated by return code 'nn' as appropriate. !xplanation: The found. User Action: indicated file Check to make sure fIlei~been entered correctly. cannot be that the 619E MODULE 'module name' NOT POUND Explanation: The module exist. ~§te.!!! Us~ requested does not Acti.Q'!!: RC = 28 Action: Recheck the ccmmand. INVALID POSITIONAL ARGUMENT 'argument' £!£!s.!!A!ion: More than the maximum number of positional arguments (i.e., arguments before the left parenthesis marking the start of the options) were specified. The number of positional arguments allowed depends on the second operand (DISRR, etc.) on the command line. This message is a likely result if the left parenthesis option delimiter is missing from the Conversational Monitor System (CMS) Messages 187 DPIS command line. ]§~ User Action: Check to make sure that you specified the correct positional arguments, and that you have not omitted the parenthesis. haVe !£!!2!: Check the command syntax. DEVICE AND LINES ARGUMEN~S ARE REQUIRED Explanation: The first two EXEClO command line operands are always required. UNKNOWN OPTION NAME 'name' ]§~~ Explanation: The indicated option not recognized by EXECIO. name is INVALID VALUE 'value' FOR NUMBER OP LINES User Action: Check to make sure that you have ~misspelled an option name. VALUE HISSING AFTER 'option' ,, ,, ,, Check the syntax !JR!!~tio!: ~he number of lines specified to be processed must be either a non-negative integer or an asterisk. ]§~ OP~ION Action: Check the value specifiEd for the number of lines to be processed. Ex~anation: There is no value specifi~d after the indicated option, yet one ~s required. For example, the MARGINS option requires that two values follow it. If one or both of these is missing, the message is produced. User Action: COHana:--- Action: Check the command syntax. of the MISSING 'DEVICE' ARGUMENT Explanation: The EIECIO 'DEVICE' argument. ]§~~ command requires a Action: Check the command syntax. INVALID 'DEVICE' ARGUMENT 'argument' VALUE 'value' NOT VALID FOR 'option' CPTION Explanation: An invalid value was specified for the indicated option. Fo~ example, if 'Case 3' is used in a call to EIEClO, the message will read ' ••• VALUE 3 NOT VALID FOR CASE OPTION.' User Action: COiiana:--- Check the syntax of the Explanation: The only valid values for the 'DEVICE' argument are CP, CARD, DISKR, DISKW, PUNCH, PBINT, and EMSG. ]ser Action: Check the command syntax. INVALID VALUE NUMBER 'value' FOR DISK FILE LINE ~lanation: 'option' OPTION IS NOT OPTION VALID WITH 'option' The line number specified is negative or a non-numeric value. User Actio!: Check the command syntax. Ex~anation: Two mutually exclusive cption values were specified. For example, only one input selection option, is allowed; therefore, if both a LOCATE and a FIND option are specified, this message will be issued. User Action: COHan-d-.-- Check the syntax of the DISK FILEMODE REQUIRED FOR DISKW Expla~: The file mode operand is required for a DISKW operation. The DISKW operation may cause writing to any disk to which the user has write access. ]~ 'option' OPTION NOT OPEBATION Action: Check the command syntax. VALID WITH 'operation' INVALID BECORD EITHER F OR V Ex~anation: The indicated option cannot be specified with the indicated operand. For example, the FINIS option is not valid if PBINT is specified as the second operand on the command line. FORMAT 'recfm' !lUST BE jxE!~~: For a DISKW operation, if the record format (recfm) is specified, it aust be either F or V. V is the default value. User Action: Check the command syntax. Us~ Action: Check the command syntax. INVALID RECORD LENGTH ARGU!lENT 'lrecl' STRING OPTION WITH LINES=* FOB CP OPEBATION IS VALID ONLY Explanation: The STRING option with LINES=* is valid only for a CP operation. 188 IBPI VH/SP System PIessages and Codes !JR!!~tion: For a DISKW operation, if the logical record length (lrecl) is specified, the value must be less than 256 and greater than O. DMS Check Us~ Actio,!!: argument. the record length Execution is terminated. 622E INSUFPICIENT FREE STORAGE [ message ] FILE PORMAT SPECIFIED 'recfm' DOES NOT AGREE WITH EXISTING FILE FORMAT 'recfm' ]lE.!S!.!!S~ion: Insufficient storage was available for task to execute a required function. One possible cause of this error message is that a program issuing NUCXLCAD is in a loop. If present, 'message' is one of the following: Ex]1!]AtiQ,!!: The record format of a record to be written into an existing disk file is inconsistent with that file. User Action: Check the record specifIed against that of the file. format FOR EXECIO RC=41 The requested function is not performed. FILE LRECL SPECIFIED 'lrecl' DOES NOT AGREE WITH EXISTING FILE LREC~ 'lrecl' FOR NAMEFIND RC=41 Execution of the command is terminated. Explanatio~: The logical record length of a record to be written into an existing disk file is inconsistent with that file. NO TABLE MADE RC=41 DMSGLO created no global variable(s) storage for the GLOBALV command. User Actio~: Check the logical record length specified against that of the file. EXECIO OPTIONS PLIST ONLY ALLO~ED (nn ENTRIES) 11C=41 CMSNXM (NUCXMAP) requires one word of storage for each nucleus extension. The command is terminated, no map is generated. WITH EXTENDED ]~]lanatiQ,!!: If any options are used in the call to EXECIO, an extended plist must be supplied. The EXEC 2 interpreter always provides an extended plist, and CMS supplies an extended plist fer all commands read from the console. The most likely reason for this message is an attempt to invoke EXECIO (with optiens) from a CMS EXEC file. Another reason may be invocation of EXECIO from a user program that doesn't supply an extended plist. Actio,!!: You may provide the extended plist by converting the CMS EXEC file to an EXEC 2 file. Or EXECIO may be invoked through a separate EXEC 2 file called from the CMS EXEC file. If called from a program, the extended plist sheuld te set up according to the documentation in the VMLSP ~.!§~~'!!! .f.£.QSf:s..!!!.!!!.§f...!.§ Q]J:de. ~tem Action: RC Execution halts. CHARACTER IN ]zE1snatio~: a character PI~E IDENTIFIER The specified fileid contains invalid for the CMS ~hat is file system. Us~ ActiQ,!!: Check the description of the command format and reissue the command using valid characters. INVALID MODE 'mode' ]Z]1anation: More than two characters were specified for the mode. Us~ = 41 User Action: Check a program issuing NUCXLOAD for a possible loop that is not terminating properly. More free storage may be obtained by releasing a disk (to recover the space used for the file directory) or deleting a nucleus extension. Alternatively, re-ipl CMS after defining a larger virtual storage size for the virtual machine. US~f INVA~IC in 622W INSUFFICIENT FREE STORAGE BUPPER, PROCESSING CONTINUES FOR NA~EFIND !~].!S!]S~io,!!: Insufficient storage was available for NAMEFIND to create a tuffer containing information from the NAMES file. The requested buffer size, or the size of the file, was too large in terms of the available free storage. ~I§~~.!!! Action: No buffer was created and processing continues reading the NAMES file from the disk. The buffer size is set to 0, so that future invocations of NAMEFIND will not cause this warning tc be displayed. Q§~ Action: None. 623S {MODULEIPHASE} CANNOT BE LOADED AT LOCATION 'location' BECAUSE IT WOULD OVERLAY THE CMS NUCLEUS. Action: Check the command syntax. £l].!S!natJ:on: This error can occur because: 1. .2.Yst~.!!! ActiQ!l (for S!.!.! YS!fiati.Q'!!§ ~ssaq.§): RC=24 The module or phase is too large to be loaded in the user area (it is attempting to overlay the CMS nucleus Conversational Monitor System (CMS) ness ages 189 D!S which resides area). 2~ at the end of the user The 'ORIGIN' option was specified incorrectly to cause the module or phase to' be loaded so that it would overlay the CMS nucleus. Systy Action: Re = 88 The command that was executed to the load is terminated. User Action: If possible, reguest less data (for example, as with the D~SPLAY com.and). 628E INVALID GLOBALV FUNCTION 'function' jxplaRation: The function specified on the GLOBALV command is invalid or unknown. system perform Aill.2l!: RC=4 !£!i2!: Reissue the command specifying a valid GLOBALV fUnction. ~ Y§~ ActioB: If the 'ORIGIN' option was incorrect, reissue the command with the correct origin. If the module or Fhase is too large, contact your system support personnel, or use the CMS nucleus 'C"SL' that is defined at a higher location, if it is available on your system. 6241 NO NUCLEUS EXTENSIONS lRE lCADED 1!R!!B!!i2B: No nucleus extensions were located and therefore they cannot be mapped for NUCXMAP. Systg ~tiQ!!: RC :;: 0 An error occurred while accessing the spool file, or the virtual reader is busy. 1he reader file may have been purged by the system, or the file may have been transferred from your virtual reader via a TRANSFER command issued by the originator or the system operator while the RDR command was executing. ~~ A£tioB: RC=36 Execution of the command is terminated. l 631E SETL/SETLP/SE!LS CAN ONLI BE EXECUTED FRO! I AN EXEC 2 EXEC OR AS A CMS COM"AND 624W NO NUCLEUS EXTENSIONS AR! lCADED lJR!an,tion: No nucleus extensions have been loaded and therefore cannot be dropped. ill!2!!: Ix~lanation: Dser A£!ioB: If the spool file is still in your virtual reader, reissue the command. If the error persists, contact your installation support personnel. Use,£ Asttion: None. System 6305 ERROR ACCESSING SPOOL FILE JA£lapatioa: This function reguires an extended parameter list, which is not provided by CMS EXEC. RC = 28 system Action: RC=4 Y§~I 626E INVALID 'parameter' ACTION ROU!INE PARAMETER Explanation: The parametex passed to module DMSPOR in the routing takle contains an invalid action routine name. sy§tem Aill2!!: None. User Action: the routing table that the parameters passed to module DMSPOR contain a valid action routine name. ~he valid action routine names that can be specified with DMSPoa are: GET TOlB LOAPTBL TCLGLOPR QUERY TOVM STOP entry.-~ke Correct ~ure 621E RESULT IS 'nnnn' CO!U!AND BU1FER BYTES TOO LARGE lOR 190 IB! VM/SP System Ressages and Codes 632E I/O ERROR IN COMMAND EXECIO: RC=nnn FROM 'co ••and' ~xplanatioB: The specifie~ errcr return code was obtained by EXECIO when the indicated command was invoked. EXECIO w~ll not continue, but returns the error r~turn code to its caller. 7hE EXECIO ope~at~on may have partially completed beforE thE error occurred. !ystem ActioB: RC=1nn, where return code from CORMAND. nn is the User Action: Look at the documentation for the indICated command to interpret the return code. CP Explanation: CP returned a response to a command that is too large to fit into the buffer provided by module DMSPOR. 51st§! Action: None (no data returned). ACs12B: Confine use of GLOBALV SETt ••• subfunction to EXEC 2 EXECs or as a CMS command. 633E TOO MANI TAGS 6q PER LINE WERE ENCOUNTERED. MAXX!UR IS ExplaB!tion: Wh~le searching the names file, entry was encountered which contained more than 64 tags (ove~flow1ng the internal tag tables of of the N1IEFIND command) • 7his record was not processeQ an-- DMS 2.l.§te~ correctly by NAMEFIND. ,Action: RC=32 Processing is terminated. created on the user's disk • .2.lst~ ActiQ1!: RC=88 Processing is terminated. Use.! A£!ill: No file is None. User Action: Make sure the entries in your names file-do not have more than 64 tags. 637E MISSING {VALUEI'value'} FOR OPTIONI'operand' OPERAND} THE {'option' 633W RETURNED VALUES WERE TRUNCATED ~!]l~n~!ion: An option or an operand that requ1res a value following it was specified, but no such value was given. Ex~~nati2B: The information that was stacked or displayed at the terminal was truncated. The stack has a limit of 255 characters; CMS permits only 130 characters to be displayed. ~yste~ Action: RC=24 Processing is terminated. User Action: Check the format of the command-and-reissue it, specifying all the required values for the options and operands. 2l1!!!.!t!!! !£!im!: RC= 8 8 Processing is completed. Q§~~ Acti~: Use the System Product Editor to view the rest of the entry. 638E fn ft fm IS TOO fm' 634E NO VALUE TO SEARCH FOR WAS SPECIFIED A note in the reader is too wide to add to a fixed format NOTEBOOK file on the user's disk, or a record could not be added to the user's fixed format NETIOG file because the record was longer than the file. Syst~ Actiog: RC=24 Processing is terminated. ~ystem Acti~n: RC=32 Processing is terminated. Either the NOTE wasn't received or the log message was not added to the user's NETLOG file. Us~~: Reissue the command with at least one tag with a value to indicate what NAMEFIND should search for. NO ENTRIES WERE FOUND SEARCH CRITERIA ~HAT MATCHED 'fn ft ]xpla~tion: ]zElgnation: The NA~EFIND command was issued without a search value (i.e., a tag with a value). 635I WIDE TO APPEND TO ]~ YOUR Ac!ion: You can use either the System Product Editor subcommand SET RECFM or the COPYFILE command to change the format of the file from fixed to variable. ]zfl~~tion: NAMEFIND was unable to locate an entry that matches the search criteria specified on the command line. 639E ERROR IN 'routine' ROUTINE. RETURN CODE WAS 'xx' ~l1!!te~ ]£!iQg: RC=32 Processing has completed. ]1El~nation: An error occurred while executing the routine specified in the error message. The return code is given to identify what the problem was. 636E UNSUPPORTED TYPE OF NETDA~A FILE §.l.§!~~ ,Action: RC=xx (whatever code was in the message above). processing is terminated. ExE1~natiog: A file in the reader is not able to be read in, because the RECEIVE command cannot reformat it. FOI exam~le, a OS PDS in NETDATA format would not be able to be received in CMS. ]~~ Action: Look up the routine mentioned and determine from the return code what the problem was. Correct the problem and reissue the command. ~§!~~ ActiQg: RC=88 processing is terminated. Use~ Acti2B: None. 636W RECEIVED NULL FILE -- NO FILE CREATED EXFlanation: A file that was read in from the virtual reader contained no data records (only NETDATA control records were sent). No file was created on the user's disk. the return 640E UNABLE TO ACCESS HELP FROM ACCESS COMMAND DISK (cuu), RC=nn Explanation: An error was encountered while attempting to access the disk that contains the HELP files. ~ystem Action: RC=100 HELP processing is terminated. ]~ Action: Check the return codes for the Conversational Monitor System (CMS) Messages 191 DMS ACCESS command problem. to better identify the same class as your virtual reader. You can use the CP CHANGE command to make the class of the spool files the same as your reader class. 640R HELP DISK ADDRESS = cuu Ex.E1anatiQ!!: "cuu" designates the device 644E ALL BEADEB FILES ARE IN HOLD STATUS OB NOT address of the system HELP disk. Cn this CLASS 'class' disk, CMS expects to find the system HELP files. I jxplaBation: No files in your reader have the same class as the virtual reader, or if I they have the same class, they are in HeLD ~l§!~ A£!iQn: The system waits for a I response. I status (they have a USER, SYS, or USYS value for the HOLD field in BDRLIST). I If you enter an invalid device address, the message DMSINI079E INVALID D!VICE ADDRESS ~l§!~! Acti~: RC=28 Execution of the command is terminated. REENTER is issued. DMSINI640R is reissued, and you may enter a valid device address. User Action: To PEEK or RECEIVE a file that Is-no~d or is not the same class as If you enter a null line, "19D" is assumed to be the system HELP disk. your virtual reader, specify the sFoolid in the command, for example, "PEEK spoolid" or If you do not want a HELP disk, enter the "RECEIVE spoolid ••• ". You can also use the CP CHANGE commmand to change the spool file system disk address as the HELP disk to NOHOLD or the class of the file to be address. the same as the reader class. User Action: Enter a valid disk address or anulliIiie. 641E NO {COMMANDIOPTIONS} SPECIPI!D 645W THE USER TAG NAME 'name' DISPLAY IN THE PANEL IS TOO LONG TO Cnly the first 12 characters of a user-defined tag name can be displayed in the NAMES panel. A~Elgng!ion: The DEFAUL~S command requires that you specify a command and at least one option when using the SET oFerand. !!~JgnatiQn: ~l§.1:~! ~l§!§! !£1iQn: RC=24 Execution of the command is terminated. Ac!ion: An entry is displayed with tag names truncated to 12. If you change this entry using the panel, the tag names will also be truncated in the file. Therefore, if you want to have tag names greater than 12 characters, edit the names file directly instead of using the panel. Q~~~ User Action: Re-issue the command and specify-a-command and at least one option. 642E DEFAULTS DOES NOT ACCEPT {'command' COMMANDI'option' OPTION FOR 'command'} ]ZElanatiQn: The DEFAULTS facility is valid only with certain commands and only with certain options for a given command. ActiQn: None. 647E USERID NOT SPECIFIED 'Userid NAMES' FILE FOR 'nickname' IN I~Elgng.1:iQn: .§.!stem ActiQ!!= RC=32 Execution of the command is terminated. User Action: Check the list cf commands and options-that can be used with the DElAULTS command. (See the !!L~g £~ £g!!!n~ A~ ~s~~Q Refer~§, or issue HELP). 643E NO CLASS 'class' FILES IN leua READER No files in your reader have the same class as the virtual reader. This may mean that your reader is empty, or that the files in your reader have a different class associated with them. The entry for the nickname specified does not contain a value for the Userid tag; therefore, communication with this user is impossible. ~1§.1:~! A£!!Qn: RC=32 Execution of the command is terminated. User Action: Reissue the ccmmand SUbStituting-the user's userid in place of the nickname, or use the NAMES ccmmand to insert the Userid in that entry. !!BlA~g: Syst~ ActiQg: RC=28 Execution of the command is terminated. ActiQn: lou can command to see if there your reader other than .Y§§~ 192 use the RDRLIST are any files in those having the IBM VM/SP System Messages and Codes 648E USERID 'name' NOT FOUND. {NO {MESSAGEIFILE} HAS BEEN SENTI CHECK THE 'Userid NAMES' FILE} The specified userid or the value for the userid tag for the specified 'name' was not a valid userid for your computer. j~ElgB!!ion: DMS Execution of the command is terminated. ]~! Action: Check the command shown in the identify the problem. User Action: Validate the value for the userid--and-insert it correctly into the NAMES file or reissue the command with the correct userid. 654E 649E EXTRANEOUS PARAMETER 'parameter' Ex£1anation: There specified than the accept. INVALID SYMBOL 'string' {I/O' MUST BE SPECIFIED ALONEI INVALID CHARACTER 'char' FOLLOWING 'I' SYMBOL} !xplaJlg!ioB: invoked with the command. were more operands command issued will return code for the message to tetter The EXECUTE subcommand was invalid symbols specified in ~~te~ Acti2B: RC=24 The command is not executed. EY2!~! ActiQA: RC=24 Execution of the command is terminated. User Action: Check the correct format the-command and reissue the command. User Action: Re-enter valIdSYmbols. of the command(s) using 655E SPOOLID 'nnnn' DOES NOT EXIST 650E INVALID SPOOLID 'nnnn' Explanatio~: There is no spool file with this spoolid number in your virtual reader. Jxplanatio~: The value representing the spoolid was not a valid spoolid numter. ~yste~ Action: RC=28 The command is not executed. User Action: Reissue Valid spoolId. 651E the {'option'I'command'} MUST environment (s) command with BE ISSUED a I FROM 656E ERROR SEARCHING YOUR NAMES FILE, RC=nn FEOM NAMEFIND COMMAND A~~!~BA!ion: EX£lanation: The command is valid only in certain environments and is not executed otherwise. User Action: To execute this command or use this -Option you must first issue the necessary command to enter the required environment. An error was encountered while searching through your 'Userid NAMES' file. ..§ystem ACQ,2B: RC=100 The search was terminated unsuccessfully. User Action: Check the return codes fer the iAMEFiin--command to better identify the problem. 657E UNDEFINED PFKEY 652E MISSING DISCARD OPERAND(S). SPECIFY EXECUTE [n] Explanation: DISCARD was issued without the correct operands. If you use the EXECUTE subcommand to issue DISCARD, the correct operands will be appended automatically • .§.Iill! .!ZiQA: RC=24 jxpla~ion: A PF key that has no function assigned to it was pressed. Q.§fi ~: None. 658W THE VALUE FOR THE 'tag' DISPLAY IN THE PANEL TAG IS TOO LONG TO Us~ Action: On a display terminal, enter DISCARD in the command area on the lines that contain the files to be discarded and press PF10. Otherwise, enter EXECUTE en] DISCARD on the command line to discard n files (the default is one), starting with the fileid displayed on the current line. !!ElsnatioB: The value for the specified tag is too long to fit onto the panel; therefore, only part of it is displayed. If this value is changed it will te truncated in the NAMES file. System !£!!2B: Only part displayed in the panel. of the value is 653E ERROR EXECUTING 'command', RC=nn ~ ~: !XRla~: An error was encountered while executing the specified command. EI§tem !£!~2n: RC=40 processing is terminated. If you change this entry using the panel, the tag values will also be truncated in the file. Therefore, if you want to have tag values longer than the space allowed on the panel, edit the names file directly instead of using the panel. Conversational Monitor System (CMS) Messages 193 DMS .§vstem Action: None. 660E THE NICKNAME PIELD MUST BE FILLED IN Exp1~ation: All entries in the NAMES file must have a NICKNAME tag tc indicate the beginning of the entry. If this field is blank, the entry will not be accepted from the panel. System Asti2B: executed. User The Action: Pill 'iiickna~-- in function the is value for y~ !£!!£B: None. 665E FILE 'userid NOTE.' NOT FOUND. TO BEGIN A NEW NOTE ENTER 'NOTE name' ~'!'p1anation: not The NOTE command was issued without any operands, which is the correct procedure when you want to continue an existing NOTE. However, no NOTE was found. the Svste! Actm: RC=28 660W WARNING: THIS ENTRY NICKNAME y§~ Acti~E: Specify a name following the command name. DUPLICATES AN EXISTING (or names) ~!Rlg~~iQB: An entry has been added or changed, and the nickname now duplicates an entry (or entries) already in the NAMES file. This entry can no longer be identified uniquely by its nickname tag. Since the CMS commands (NOTE, SENDFILE, and TELL) that search the 'Userid NAMES' file often search based on the nickname tag, only the first entry that begins with this nickname will be used. 666E NOTE ALREALY EXIST. ENTER 'NOTE' CONTINUE OR SFECIFY 'REPLACE' OPTION TO ~!E!~B~!io~: The NOTE command was issued with a name or names following the command. However, a NOTE already exists. you can process only one NOTE at a time. .§'y§g,! ActioB: RC=28 M~ 2.Istem !£lion: None. Use~ !ctio~: You may wish to change the nickname value and press PF6 to ensure that this entry can be uniquely identified by the CMS commands that reference the 'Userid NAMES' file. Also, by pressing PF5 repeatedly you can locate all the entries that have this nickname and then decide which nicknames that you wish to change. Action: You can either specify NOTE with no operands to finish processing the existing note, or you can reiSSUE the command and specify the REPLACE option, which discards the existing note and begins a new one. 667E NOTE HEADER DOES NOT CONTAIN THE {KEYWORD {'FROM'I'TO'} "OPTIONS" 'DATE LINE} EXE!~~!ioB: 662W YOU ARE NOT ON AN ENTRY. FRESS PF 5, 7 or 8 TO MOVE TO AN ENTRY Ex]!gBation: The command issued was not executed because you were not positioned on an entry in the file. Syst~! Actign: None. User Action: entry-.--- Use a PF key to move to an The NOTE header must have a line that contains the options, a line containing the date, a line indicating the sender of the note, and a line indicating the recipients. These lines are denoted by the keywords "OPTIONS:", "FROM:", "DATE:", "FROM:" and "TO:", respectively, beginning in column one of these lines. If these lines are not present, the NOTE has an invalid format and cannot be sent using the NOTE option of SENDPILE. !£!i2n: RC=32 Processing terminates. .§y§!~.! 663W THERE {lSI ARE} nn UNDISPLAYED TAG(S) EXE!anation: This entry contains 'nn' more tags than can be displayed in the panel. User Action: headerlineS. Correct the format of the 668E THE 'ADD' OPTION MUST BE SPECIFIED ALONE User Action: If the entry is deleted, the undisp1ayed values are also deleted. If the entry is changed, the undisp1ayed tags are not changed. To change these tags you must edit the 'userid NAMES' file. 66~W {ENTRYIPREVIOUS ENTRYINEXT ENTRY} NCT FOUND ~Rlanation: PP 5, 7 or 8 was pressed and the search failed to find an entry. 194 IBM VH/SP System Messages and Codes ExplanatioE: No other options are when the ADD option is specified. valid !£!i2B: RC=40 Processing terminates. §Y§1~'! User Action: Reissue the command using only 'the-ADD option. DBS 669E LIST OF ADDRESSEES CANNOT BEGIN WITH 'CC:' JzRlanation: 'CC:' is used to denote a list of compl~mentary copy recipients and cannot ~e the first addressee of a NOTE. Us~ !£!!2B: Reissue the command, with the addressee preceding the 'CC:' rEcipients. Explanation: The ADD option was specified without any names to be added. System .!£li5m: RC=24 Processing terminates. Action: ADD option. requires a READY System Action: RC=32 User Action: Use the CP READY command to change the status of the virtual device. ~hen reissue the command. 610E NO NAMES TO BE ADDED WERE FeUND specifying~he 614E {READERIPUNCH} NOT READY lIplanation: The command issued that the device specified have status associated with it. .§.lste! Acti.Q.B: RC=24 Processing terminates. User any addresses. 615E NC NAMES SPECIFIED The SENDFILE command requires that you specify the name(s) of the recipient(s} of the files (unless the fiie is a NOTE). ~nation: Reissue the names to be added command, with the ~.!!! !£ligj!: RC=32 Action: Reissue the command, specifying the name(s) of the recipient(s). ]§!! 611E ERROR {SENDINGIRECEIVING} FILE RC=XX FROM 'command' 'f~ ft fm' !!£!anation: An error occurred while attempting to send or receive a file. 616E INVALID CHARACTER ' •• FOR NETWORK ID SENtFILE is attempting to SEnd file to another node, which should be connected to your computer via an RSCS machine. However, the RSCS ID (or NETWORK ID) has the value '.', which is not a valid ID. l!Rlana~: Syst§! !£i!~: RC=100 a User Action: To further identify the problem, check the return code specified in the message for the command that encountered the error. Syste! 612E VIRTUAL DEFINED {PUNCHIREADER} INVALID OR NOi Explanation: The specified device was not defined at the correct virtual address. The virtual reader must tE definEd at the virtual address OOC and the virtual punch must be defined at OOD in order for the command issued to function properly • .§.lstg Action: RC=32 User Action: Use the CP DEFINE command to define the device at the proper address. Then reiSSUe the comman~. 613E ADDRESSEES ARE IN THE NOTE HEADER RECORDS, DO NOT SPECIFY NAMES WITH THE NOTE OPTION E!R!anation: The NOTE option of the SENDFILE command was issued with a name or names of people who were to rECEive the file. However, the reCipiEnts of the NOTE being sent should be contained in the NOTE header records; the names specif~ed on the command line are extraneous. System Acti~: RC=24 A~: RC=20 ]§§! !£tion: There is evidently a protlem with the 'SYSTEM NETID. 'file. This file should contain information atout the Network ID. For more information about this file, see the description in the lDENTIFY command. Contact your system support personnel. The person responsitle for building your system is responsible for maintaining this file. 611E INVALID OPTION 'option' IN OPTIONS LINE Explanation: The OPTIONS line in the NOTE header records contains an option that is invalid or not in the correct position. The five options on the line following tbe keyword 'OPTIONS:' are expected to contain specific values and be in the corrEct order. ~! Action: RC=24 User ~: Check the format of the options line as described in the NOTE command description and correct the invalid option and/or make sure that the order in which the options appear on the line agrees with the order in the NOTE command description. User Action: Check that the proper addresseesa:re contained in the NOTE header and reissue the command without specifying Conversational Monitor System (CBS) Bessages 195 DMS 678E INVALID NOTE HEADER SENT FORMAT. NOTE CANNOT BE Ex~anatiQB: The SENDFILE command was unable to send the NOTE becausE the format of the addressees in the NO~E was not what the SENDFILE expected. Depending on the value of the format option (LONG or SHORT) in the 'OPTIONS' line of the NO~E, SENDFILE expects the addressees to have certain formats. If the LONG option was specified, each line must contain one addressee, that can be identified in the form "Userid AT Node". If the SHORT format is specified, everything following the 'TO: 'keyword is an addressee in the ferm "Userid" or "Userid AT Node". User Action: If the header format is Incorrect,-try to correct the format of the addressees. Check the description of the NOTE header format (which depends on the LONG and SHORT options) in the description of the NOTE command. 681E THIS IS AN UNNAMED FILE, AND FILETYPE SPECIFY FILENAME 1AElanation: The spool file being received has no fileid. It must have a filename and filetype in order to bE identified. Syst~~ Actio~: RC=88 Use~ Action: Reissue the command, specifying--a filename and filetype. See the RECEIVE command description for more information on the command format. 682E ERROR COPYING FILE 'fn ft' FROM 'A' DISK TO ('fn ft fm'l'mode' DISK), RC=nn FEOM 'COPYFILE' gll.EJ:g.!!s.!ion: 'Ihe file was sent using the DISK DUMP command and had to be read onto the A-disk using the DISK LOAD command. At that point the RECEIVE command attempted to use COPYFILE to copy the file from the A-disk to the disk specified in the error message. However, the COPYFILE command failed to execute and returned the specified return code. 679E (DISK 'mode' IS READ/CNIYIDISK 'mode' IS IS NOT ACCESSED). NOTE FULLIDISK 'mode' CANNOT BE SENT Qse~ Ex£1angtiQB: For the reason specified in the message, the SENDFILE command was unable to send the NOTE. In order to send the NOTE, SENDFILE must first save the NOTE on a disk. It cannot do this if the disk is full or if the disk has read/only access. §~st~ ActiQll: RC=36 The note is not sent. User Action: If the disk is full, try to make some--space available by erasing any unwanted files. If the disk is accessed read/only, use the eMS ACCESS command to access the disk for read/write capability; or change the filemode to one that is a read/write disk (you can use the System Product Editor subcommand "SET FMODE mode" to do this). 680E INVALID FILEID 'FILELIST' OPTION SPECIFIED WITH THE FILELIST option is used to indicate that the file identified as 'fn ft fm' actually contains a list of files to be processed by the command. If the FIIELIST option is specified, no pattern matching characters (* or %) may appear in the fileid. ~.!.ElanatiQB:The User Action: Do not use the FILELIST option:-or--specify the complete fileid of the file that contains the list of files to be processed. 196 IBM VM/SP System Messages and Codes Action: See the description of the COPYFILE command for more information about the return code. The file specified in the error message is still on your A-disk and you can do with it as you want. If there was a file with the same fileid on your A-disk before RECEIVE was issued, the original file is renamed "$A$A$A$A $B$B$B$B A". Take the proper actions to restore the files to the fileid you want. 683E THE ENTIRE FILE REFORMATTED MUST BE PEEKED AT TO BE ~~lans!iQ.!!: The PEEK command reformats spool files that are in DISK DU!P or NETDATA transmission formats to make them mere readable. To do this, the user must PEEK at the entire spool file. The default for PEEK is to peek at the first 200 records in a spool file. §I§!~~ Actio.!!: RC=32 The file is not reformatted. Q~~~ Actio.!!: If you want to look at the file reformatted, reissue the PEEK command using the FOR and FROM options. To PEEK at the entire file, use "PEEK spoolid ( FROM 1 for *). You can change the default options of PEEK (originally FROM 1 FOR 200) by using the DEFAULTS command. 683W THE FILE HAS AN LRECL GREATER THAN 255 and CANNOT BE REFORMATTED ~!.EJ:g.!!atio.!!: The PEEK command cannot reformat a file whose logical record length is greater than 255. DMS ~.§tem Acti,Q.!!: RC=32 The file is not reformatted. 7021 :READ fn ft fm j~£l~natioB: User Action: This file cannot be peeked at in-readable form. Use RECEIVE to read the file in. 684E FILE CONTAINS INVALID RECORDS AND CANNOT BE REFOR!UTTED ExE1~atioB: The spool file contains records that PEEK does not recognize as the correct format for DISK DUMP or NETDATA format files. This message is displayed for every READ control card encountered during a READCARD operation. When there are no READ control cards, the following messages are displayed: READ CONTROL CARD IS MISSING. ASSUMED: :READ READCARD CMSUT1 A1 This indicates that the file READCARD CMSUT1 A1. FOLLOWING is read in as System ActioB: processing continues. ~Y.§ig~ !£iion: RC=32 The file is not formatted. Us~ Us~~ Action: If the file has been read in as READCARD CMSUT1 A1, rename it to a desired fileid. ActiQB: None 7031 FILE 'fn ft [fm]' COPIED 684W WARNING: THIS FILE HAS NO EECORDS ~lanation: ]~planatiQB: A file, sent from an MVS system in NETDATA format, contains nc data records. It is a null file and there are no records to PEEK at. The named file has been copied from tape to disk. ~tem !ctiQB: RC=32 An empty file is displayed by PEEK. ].§~ 7041 INVALID CLEAR REQUEST !~anat~gB: A CLEAR for a file definition No action took place. !£ti2.B: None. 687E THIS IS A SYSTEM {HELDIDUMP} FILE. FILE CANNOT BE {PEEKED ATIRECEIVED} reguest was entered that does not exist. THIS ~Y§!~ Ex~lanati.Q.B: A file in your reader has a SYSTEM hold on it (status SYS or USYS) or is a system dump and as such cannot be received or peeked at. !£tiOB: None. User Action: Correct the file specifIea-in the CLEAR reguest. definition 7051 DISK REMAINS UNCHANGED Systg,m .!£j:ion: RC=1 j~lanation: User Action: If the file is SYS!EM HELD, request that the operator change the spool file status to NOHOLD. If the file is a SYSTEM dump file, refer to the documentation for the VMDUMP and VMFDUMP commands. The reply to DMSFOR60SR was not "yes". ~1§!g~ ActioB: unchanged. QB~ Act~gB: None. The disk remains Enter the next command. 7011 NULL FILE ]~E!g~gtion: There were no records in the 7061 TERM INPUT DATA -- TYPE NULL LINE FOR END OF file. ]~gnation: For DMSRDC, two READ control cards were encountered, but there were no cards available to be placed in the first file. For DMSTPE, an end-of-CMS-file found, but there were no other the file. record was records in The input ddname in the MOVEFILE command refers to a terminal. This message requests the input data to be copied to the output device or file. ~lB!g! !cti2.B: response. The system waits for a User Action: Enter data or a null line. Systg~ Action: Processing continues. User Action: If records were expected, the fIle ShOUld be resubmitted. 7071 TEN FILES COPIED J~£l~BatioB: Ten members have been copied from tape to disk as a result of the MAX!EN option. Conversational Monitor System (CMS) Messages 197 DPlS ~§!n User !£.till: None. Acti.Q!!= None. ll§§t Action: None. 7211 COpy 'fn ft fm' [{TOIAPPENDIOVII} 'fn fm' {OIDIN!W} FILE] Al' 7081 DISK FILE 'PILE ddname DDNAME 'ddname' ASSU"ED ft FOB jlEl~n~tion: l!~ation: No 'ILEDEF command was issued for a--adname specified in the "OVEFIIE command. As a result, the !CVEFILE command issues a FILEDE~ for that daname. If this is the input ddname, the disk file must exist on disk. The blocksize and record format are taken from the characteristics of the input disk file. If this is the output ddname, the disk file is created on the A-disk. Its characteristics depend on the format of the input file. Syst§! ACti2n: Processing continues. This message appears in conjunction with the TYPE option. It indicates the name of the input file and output file. ~l§!!! Action: None. ..Y.§.§.! Action: None. 7221 FILE 'fname2 OUTPUT LISTING fm' WILL HOLD AMSEBV The Access Method Services output will be placed on the given disk (other than the user's A-Disk). This information message is omitted if the output file is placed on the user's read/write A-disk. 1~~i2A: User Action: NOlie. ~l§!!! 7101 PHASE xxxxxx 'phase' ENTBY PCINT ~~tion: AT The phase entry located at location xxxxxx. LOCATION point is ]~~ Acti2n: processing continues. Action: None. 7231 mode (cuu) {B/OIB/W} [-OSI-DOS] l!El!nAti~: ~!!~!l Acti.QB: None. User Action: Issue begin execution. the STABT command to The specified CMS-formatted disk is accessed in read-only mode. -OS indicates the disk is OS-formatted. -DOS indicates the disk is DOS-formatted. !2!~: A read/write OS or written on only by VSAM. DOS disk Can be 7111 NO SYSTEM SYNONYMS IN EllECT ~1§!§! Acti~n: processing continues. l!R1A~n: No system synonyms are in effect because you previously issued a SYNONYM command with NOSTD specified as an option. 7241 'cuu' REPLACES 'mode (ccu)' ~l§!!!l !£!i~: None. ~ Action: If you want to have system synonyms in effect, issue the SINONIM command with the STD option. l!E1!n!!im!: The disk that was accessed replaces the disk specified in the search order. The disk it replaces is released, but is not detached. ~l§!!! 7121 NO SYNONYMS. ~xElanation: .!l§n Action: None. ~he routine that handles synonym processing is not in this system; therefore, no synonyms are in effect. ~§! Aill21!: None. User Action: None. I 7151 {DOSGENICMSIGEN} COMPIE~E Explanation: The CMS text decks have been successfully loaded into the discontiguous shared segment and the CP SAVESYS command has been issued to save the system. §!stem Action: None. 198 !£li21!: Processing continues. (DMSINA NOT IN NUCLEUS) IBM VM/SP System Messages and Codes 7251 cuu ALSO = 'mode' [-OSI-DOS] DISK jlE!~nati2n: The specified disk is also accessed as the 'mode' disk. The -OS indicates that the disk is an OS disk; The -DOS indicates that the disk is a DOS disk. Syst§! Action: Processing continues. .!l§u Action: None. D!S 7261 'cuu mode' RELEASED 7501 ZAP PROCESSING COMPLETE ~ARlanation: The specified device has been released since the user has specified another disk for that mode. Syst§! !£!i~: jxplaBation: An END control record was encountered and processing is terminated. .§I§!g! Action: All files control returns to CMS. processing continues. are closed and !!§fi Action: None. 7511 MEMBER 'name' POUND IN LIBRARY 'litname' 7281 DEBUG ENTERED AT xxx xxx ] [EXTERNAL INTIBREAKPCINT nn ]~snation: If more than one LOADLIB or TITLIB was specified, this message tells you which library the member was found in. lZRlanation: The system has entered the DEBUG environment. For a full description of DEBUG, see the llLSP CM.§ .Y~'!§ guide and the VI1LSP ~11'§ £;.Q!!!sl!g sl!.2 Mag~ ~§~§!! Acti~l!: 1!lli~~~ Syst~ ActiQ~: The system waits for 777S DOS PARTITION FETCH REQUEST Acti~: ~: FCR!UTTED TO ACCOMMODATE .§I§te! Action: RC = 104 Execution of the command is terminated. Q§g! Action: Redefine the size of the virtual--pirtition using the SET DCSPART command and reissue the command. Note that redefining the partition size causes storage to be reinitialized, and therefore any previous loads or fetches must te reissued. Processing continues. None. 7331 PORMATTING DISK 'mode' 1Z]!anati~: The PORMAT command formatting the specified disk. Syst§! SMALL EX]lanation: The virtual DOS partition is too small to accommodate the FETCH request. If the module or phase requested were fetched into user storage, it would exceed EPEND. EXRlanation: This message tells you how many cylinders or FB-512 tlocks haVE been formatted on the specified disk. User TOO Enter a DEBUG sutcommand. 7321 'nnn' {CYLINDERSI FE- 512 ELOCKS} ON DISK 'mode (cuu) , ~ystem Actiol!: None. the next command. ~fi !£!i~: Q§~! Processing continues. Acti~: is 825E 'CLEAR' IS ITSELF VALID ONLY WHEN SPECIFIED BY Processing continues. I!E~l!j!tion: 7381 RECORD LENGTH IS 'nnn' BYTES ~E!~ation: The message indicates the length of records read in when it is not 80 bytes. lil~ Q§fi ActiQ~: Acti~: Processing continues. None. 7401 EXECUTION BEGINS ••• EXElanation: The user has requested execution of a program under CMS. ~stel ActiQl!: The program has been prepared for execution by the CMS loader and control is now passed to the program. User Action: None. CLEAR, CLEARALL, CLEARIO, or CLEARMC was specified along with other parameters. This is prohibited. The CLEAR parameter must be specified by itself, with no reports requested. No report is printed. .§l§!g! !ctiol!: RC = 12 Execution of the command is terminated. The system status remains the same. No clearing takes place. No reFort is printed. Usg~ Action: Reissue the CPEREP command requesting--the report without the CLEAR parameter. After the report is generated, issue CPEREP again with only the CLEAR parameter, or use the ZERO parameter with other parameters (where compatible) to generate a report followed by immediate clearing. 826E EREP TXTLlBS NOT POUND jxplanation: In attempting to search the EREP TXTLIBs, DMSIPC found that the pointer to the first TXTLIB contained zeros • .§.l..2tem Action: RC = 56 Conversational Monitor System (CMS) Messages 199 DMS Execution of the command is terminated. The system status remains the same. Us~ ~: Issue a GLOBAL TXTLIB ccmmand listing the applicable EREP TXTtIEs in the proper search order. If nc local libraries exist, the command should be: GLOBAL TXTLIB ERPTFLIE EREPlIB Reissue the CPEREP command. If the error persists, call your system support personnel. 8281 CPEREP ZERO OR CLEAR HAS BEEN COMPLETED ~lana!iQB: CLEAR or ZERO was specified by the user or other parameters caused ZERO to be requested by default. The VM/370 error recording cylinders have been erased, except that only the I/C error recording cylinder was erased if CLEARIO was specified; or only the machine and channel check error recording cylinder was erased if CLEARMC was specified. Acti,Q!!: RC = 0 Control returns to CMS. ~ste.! Us~ Actigg: None required. 829W ATTEMPTED 'ZERO' WAS PRIVILEGE CLASS F SUPFRESSEt. EEQUIRES Explg~: CLEAR or ZERO was specified by the user; or other parameters caused ZERO to be requested by default. The VM/370 error recording cylinders were not erased because the user was not authorized. Only class F users have authorization to erase the error recording cylinders. ActigE: RC = 88 or Re = 0 If the CLEAR function failed, the return code will be 88. If the ZERO function failed, the return code will be O. Reports (if requested) have already been generated. Control returns to CMS. ~st~.! User !ctiOD: None required if ZERO was requested by mistake or default. If you need to erase the error recording cylinders, see your system support personnel to get a class F directory entry. 830E I/O ERROR READING A BLCCK OF THE ERROR RECORDING CYLINDERS RECORDS FROM Ex~anation: DMSREA, the CPEREP read module, encountered a permanent input/output error while attempting to read a 4K block of records from the error recording area. Probable hardware error. Systm!! Acti,Q!!: RC = 60 Execution of the command is terminated. The system status remains the same. error recording cylinders. If the reconstruction process is successful, initiate the CPEREP operation again. If the error recurs, call your system support personnel. 831E MORE THAN 100 CHARS OF OPTIONS SPECIFIED IZE!!~tig~: The maximum number of characters that can be used to specify options for this command is 100. More than 100 characters were used. .§.I.§!u !£!iQ~: RC = 62 Execution of the command is terminated. The system status remains the same. !£!!QE: Check the valid command options. Reissue the command using less than 100 characters to specify the options. y§~~ 832S SOFTWARE INCOMPATIBILITY AT THE CPEBEE-EBEP INTERFACE. CODE=nnn l£El!nation: CPEREP is OS/VS EREP running under CMS with CPEREP providing interface code between OS/VS EREP and CMS. Some change has been made to OS/VS EREP (via PTF, or a new release, etc.) that has made it incompatible with the interface provided by CPEREP. Code Meaning --1-- An EXCP was attempted with a DCB other than that of the SYS1.LOGREC data set. 2 OS/VS EREP is expected to use only one lOB and one channel program when it uses EXCP to access the SYS1.LOGREC data set. But it has attempted to use lOBs or channel programs at more than one location in storage. 3 The expected read/write command in the channel program for accessing SYS1.LOGREC contains an unexpected op code. 4 While reading error records (with EXCP) from (simulated) SYS1.LOGREC, OS/VS EREP made an attempt to read nonsequentially prior to completion of the sequential reading phase. S An attempt was made to read record 2 of 'SYS1.LOGREC (the time stamp record) which CPEREP does not Simulate. 6 The first EXCP to SYS1.LOGREC was not the expected read of the SYS1.10GBEC header record. 7 The channel program for accessing SYS1.LOGREC does not have the expected format. 8 An invalid disk address (CCHHR) was used while attempting to access SYS1.LOGREC. SYS1.l0GREC. 9 There are no error records and yet OS/VS EREP attempted to read error records. 10 An invalid record length was encountered while reading SYS1.LOGREC. This may be due to error records being overlaid on the error cylinders. Y§~ !£1iQE: Execute the DDR service program to obtain a dump of the error recording cylinder on which the input error occurred. Reconstruct the data on the 200 IBM VM/SP System Messages and Codes .§ni§!!l !ctigll= RC = 104 Execution of the command is terminated with EEEP message(s) IFC1351 or IFC149I. Des User Action: Reissue the command, or have your system programmer try it. If the problem persists, call your system support personnel. 17 A variable-length record is greater than 65K bytes. The number of records is greater tban 1 for a variable-length file. The maximum number of data blocks (16060) had been reached. An invalid character appears in the filename. An invalid character appears in the filetype. 18 19 901T UNEXPECTED ERROR AT 'addr': PLIST 'plist fn ft fm' AT addr, BASE: addr, RC nn 20 21 Ex£!~ti2n: An unexpected error occurred in COPYFILE or LCADLIB processing. The "plist" indicates one of the following CMS functions: RDBUF, WRBUF, FINIS, ADTLKP, or RENAME. The return code "nn" indicates one of the following conditions: 'plist· = RDBUF £.Q~ ~!!g 1 2 3 5 7 a 9 11 12 13 14 15 The file was not found. The address of the tuffer was not within virtual storage limits. A permanent disk error occurred. This may occur if you link to and access another user's disk, and try to read a file that was refiled by its owner after you issued the ACCESS command. Reissue the ACCESS command and try to read the file again. The number of records is less than 0 or greater than 32768. The fixed/variable flag is not F or V. The record read is lcnger tban the buffer. The specified file is open for writing; it must be closed and opened for reading. The number of records is greater than 1 for a variable-length file. The end of the file was reached. An invalid displacement appears in the AFT for a variable-length file. An invalid character appears in the filename. An invalid character appears in the filetype. 'plist· = 'plist' = FlNIS £.Q.Q! Mean1B.,9 6 The file is not open. ·plist· = ADTLKP £ode MeagBSI 1 The matching ADT block was not found. 'plist' BENAME Code .!1!aning 2~- The mode is invalid, or the fileid is incomplete. 28 The file was not found, a new file already exists, fileids are identical, or the file is inactive. 36 The disk is not read/write. ~I~1g! A~: = BC 256 Execution of the command is terminated. The system status remains the same, with the following exceptions: • If the APPEND option was specified and the copying process began before the error was discovered, records haVE been appended to the output file. • If the NEWFILE (the default), REPLACE, or OVLY option was specified, and the copying process began before the error was discovered, then COPYFILE CMSUT1, on the output disk, contains the records copied so far. • If multiple-output-file mode, several output files may have been created before the error was discovered. WRBUF Co.Qg Meaning 2 The virtual storage address equals zero. 4 The first character of the filemode is invalid. 5 The second character of the filemode is invalid. 6 The record number or number of records is too long. 7 An attempt was made to skip over an unwritten variable-length record. a The number of bytes was not specified. 10 The maximum number of CMS files (3400) was reached. 11 The fixed/variable flag is not F or v. 12 The disk is read-only. 13 The disk is full. 14 The number of bytes to be written is not integrally divisitle by the number of records to be written. 15 The length of this record is not the same as that of the previous record. 16 The characteristic (F or V) is not the same as the previous record. = !ha!~ A,gtion: Refer to the "plist" parameter and the RC "nn" parameter to determine if an input/output error occurred. If it did, try to reissue the command. Otherwise, contact your system support personnel for assistance. 902T IFL DEVICE READ I/O ERBOR )!Rl~!2n: An uncorrectable I/O error occurred while reading a CMS nucleus. ~l§!!~ ~io~: The system enters a wait state. y§~ Ac!!2B: Call your installation support personnel. Conversational Monitor System (CMS) Messages 201 DMS 903T IMPOSSIBLE PHASE CODE 'xx' 907T I/O ERROR ON FILE 'fn ft fm' ~z£!~~g: A phase code larger than the maximum was detected during the file copying operation. This error should never occur. ~~§!~~ Acti£~: RC = 256 Execution of the command is terminated. The system status remains the same, with the following exceptions: • • If the NEWFILE (the default), REPLACE, or OVLY option was specified, and the copying process began before the error was discovered, then COPIlILE CMSOl1, on the output disk, contains the records copied so far. In multiple output file mode, several output files may already have been created before the error was discovered. User Action: Contact your system personnel~or assistance. 904T UNEXPECTED 'addr' UNPACK ERROR AT Expl~atio~: The system tried to close a file that had not been opened or could not find a file that should exist. For DMSHLP, an error occurred while attempting to read from the reguested HELP text file. For DMSUTL, an attempt to obtain information about a memter of the library resulted in a return code that indicated a permanent I/O error had occurred. RC = 256 Execution of the command is terminated. For DMSLBM, the MACLIB condition is unpredictable. ~~§!~~ A£!i~: Oser Action: For DMSLBM, issue MACLIB MAP to-cheek-the validity of the library name. support For DMSLIO, if the error is in a TITLIB, check the integrity of the dictionary. 'addr', BASE For DMSUTL, if the error is in a 10ADLIB, check the integrity of the directory. Ex]la~atiQn: An error condition was detected during the process of unpacking a file. Probably, the file was not in PACK format, or it was modified after it was packed. Reissue the command and if the problem persists, contact your installation support personnel. Syst~~ ActiQQ: RC = 256 Execution of the command is terminated. The system status remains the same, with the following exceptions for DMSCPY: • • If the NEWFILE (the default), REPLACE, or OVLY option was specified, and the copying process began before the error was discovered, then COPIFILE CMSOl1, on the output disk, contains the records copied so far. In multiple output file mode, several output files may have been created before the error was discovered. ~§~ !£!iQg: Contact your installation support personnel for assistance. 905S WRITE-INHIBIT SWITCH SET ON nRIVE ••• NOTIFY OPERATOR Ex]l~~~: CMS tried to write on a virtual disk that resides on a disk whose "write-inhibit" switch was set. ~~~ Action: DMSDIO returns to with a c0(1e6-; "FILE IS READ-ONLI." caller !£!!Qn: Notify the system operator to reset the switch; then IPL CMS again. Us~ 90aT FILE SYSTEM ERROR DETECTED. VIRTUAL 'cuu'. REASON CODE 'nn' ~1El~~!iQg: An error has been detected indicating that the CMS file system may have become disoriented with respect to the disk having virtual address ·cuU·. • Dn' indicates the nature of the error; it may be one of the following: fode Meaning An error was detected in trying to 3 read from or write on a disk. Probably the disk was detached (via the DETACH command) without having been released (via the RELEASE command), or the disk is an unsupported device. Error detected in module DMSDIO. A deallocation was attempted on a nonallocated DISK block, or a !ARK operation was attempted on a block already allocated. The error was detected in DMSTBK, or a RtTRK/WRTRK operation was attempted to a DISK block number zero. The error was detected in module DMSDIO. The cylinder number as calculated in CMS is not within range of user's disk, or an attempt was made to write on system disk (MODE=S). Error detected in module D!SDIO. A deallocation was attempted non-allocated disk block. The was detected in D!STRK. 202 IB! VM/SP System Messages and Codes ADDR on a error DltS 5 The cylinder number received by the Control Program is not in the user's range or an attempt was made to access file record zero. Error detected in module DMSDIO. 6 An attempt was made to write on a read-only disk. Error detected in module DMSDIO. 8 A channel programming error occurred. Error detected in mcdule DMSDIO or a deallocation was attempted on a block outside the range of the DISK structure. The error was detected in module DMSTRK, or a RDTRK/iRTRK operation was attempted with a byte count of zero. The error was detected in module DMSDIO. c An I/O error occurred while writing the volume label to commit an ACCESS ERASE operation. The error was detected in DMSTRK. 13 An I/O error occurred during a RDTRR/iRTRK operation to an FB-512 device. The error was detected by DMSOIO. 18 A plist error was encountered during a truncate operation. The error was detected by DMSERS. 19 A storage error occurred during a truncate operation. The error was detected by D~SERS. 1C The file or ADT for a truncate operation was not found. The error was detected by DMSERS. detected in module DBSTRK. 81 No free block is available for allocation. Error detected in module DMSTQQ. 82 A parameter list error occurred. Error detected in module DMSiQQ. ~l§!~! Action: The system enters a disabled wait state. The user file directory is not updated. ]§~I !gtion: IPL CMS aga~n. If data on the pack is still good, re1ssue the com.and. If the problem persists, contact your system support personnel. 909T PERM I/O ERROR ON 'cuu'. CSW cccccccc SENSE ssssssss ssssssss ssssssss ssssssss ssssssss. cccccccc ssssssss IJEllnation: An uncorrectable I/O error has occurred on virtual device address 'cuu'. The CSi bytes at the time of the error are indicated at the lowercase "c" Fositions and sense data appears at the lowercase Us" positions. ~l§!~! A£!i2!: The system enters a disabled wait state. The user file directory is not updated. Y~I Action: IPL CMS again. Reissue the command. If the problem persists, contact your system support personnel. 9511 INVALID SVC nne GAM/SP NeT INSTALL!D 24 The file to undergo truncation was located on a R/O disk. The error was detected by DMSERS. 25 A storage error occurred during a RDTR/WRTRK operation. The error was detected in module D!SDIO. 28 A FINIS error occurred truncate operation. ihe detected by DMSERS. during a error was 2C Inconsistent V-Format pointers were detected during a truncate operation. The error was detected in module DHSERS. 41 No free block is available for allocation. Error detected in module DMKTRK. You may recover files from this disk if you access it as read-only and copy the desired files to another disk. 42 A parameter list error occurred. Error detected in module DBSiRK. 45 The cylinder number received by the Control Program is not in the user's range, or an attempt was made to access file record zero. Error !!R!~2!: The SVC was issued as the result of a program executing an I/O macro for a graphics device, that is, a device defined in a DeB with DSORG=GS. The SVC requires the use of the shared segment (CSMGAM) containing GAM/SP, but this segment could not be found. Syst£! Acti2!: Execution of the SiC is terminated, and control is return~d to the program. J!.§!.! A~tion: 1. If the attempted use of GAM/SP was intentional, ask a system programmer to ensure that GAB/SP is installed correctly. 2. If the program should not be attempting to use GAB/SP, that is, if it did not open a DCB with DSORG=GS, check DCB whether the has been unintentionally overwritten. 952E VIRTUAL STORAGE SIZE TOO LARGE FOR 'CBSGA!' SHARED SEGftENT TO LOAD Ai nnnnnn IJEl!n!tion: An attempt was made to load the shared segment (CKSGAft) that contains GA!/SP for use by an application prograa. The address at which the shared seg.ent must be loaded is lower than the virtual Conversational Bonitor System (CftS) Messages 203 DMS machine's highest address. A shared segment can be loaded only at an address above the highest address in any virtual machine that uses it. Syst~ Actio~: loaded, and program. The shared segment is control is returned to EEEOE. Control is returned to the User Action: Ask a system programmer correct~-paging errors. 956E 'CMSGAM' SHAEED SEGMENT ADDRESS FOE SVC nn IS ZERC !£!i£B: program. to not the User Action: Either ask the system programmer-to redefine the address at which the shared segment is leaded, or define a smaller virtual machine using a CP DEFINE STORAGE command. 953E ~y§!~~ MODULE INSUFFICIENT BLOCK FOR GAM/SP ANCHOR ]l12la~~~: An application program was using the shared segment (CftSGAM) containing GAM/SP. After being loaded, GAM/SP issued a DMSFREE macro to obtain storage in the user's virtual machine for a control block known as the anchor block. Insufficient storage was available. ~!~ EX12lanatiQ!!: The SVC was issued as the result of a program executing an I/C macro for a graphics device, that is, a device defined in a DCB with DSORG=GS. The SVC requires the use of a shared segment (CMSGAM) containing GAM/SP. This segment includes a list of addresses of GAM/SP modules, and one of these was found to be zero. STORAGE Action: program. Control is returned to the User Action: Define a larger virtual machine-using a CP DEFINE STORAGE command. 995E UNABLE TO OETAIN FREE STORAGE FOR PROCESSING. REDEFINE STORAGE SIZE. DMSEOP ]~121g~atio~: ~st~ Actio~: Execution of the SVC is terminated, and control is returned to the program. User Action: Ask a system programmer to ensure-that-GAM/SP is installed correctly. 954E 'CMSGAM' SHARED SEGMENT INVALID FOE SVC nn ERROE. IDENTIFIER A program executing under CMSDOS tries to open a DTF. Not enough free storage was available to satisfy requests issued by the DMSBOP routine (OPEN). The DTF is not opened. ~yst~~ !ctig~: RC = 104 The program is cancelled. User Action: Redefine the storage size of your -virtual machine, or return free storage that is not required. ~ZElanatio~: The SVC was issued as the result of a program executing an I/O macro for a graphics device, that is, a device defined in a DCB with DSORG=GS. The SVC requires the used of a shared segment (CMSGAM) containing GAM/SP. This segment should contain a constant that identifies it as being the GAM/SP shared segment, but the constant could not be found. Syst~~ Actio~: Execution of the SVC is terminated, and control is returned to the program. Us~ Action: Ask a system programmer to check -whether GAM/SP is installed correctly, and if se, whether the CMSGAM shared segment has been loaded but then overwritten. 955E 'CMSGAM' SHARED SEGMENT PAGING WITH ccccccc 996E NO LOGIC 'filename' MODULE POINTER IN DTF FOR ]XE!anatio~: A program executing under CMSDOS issued an OPEN for a DTF called 'filename'. Since the DTF is type SD, the program must pass the pointer to the logic module. OPEN checks the DTF for this pointer if the DTF device is not FB-512, and if the pointer is zero the DTF is not opened. ~Y§!.m!! !£!io~: RC = 104 The program is cancelled. User Action: Update the program initialize-the logic module pointer. to I/C ERRORS I 999E NO ft MODULE FOUND ~~E!~natiQB: EXE!~~tiQ!!: An application program was using the shared segment (CMSGAM) containing GAM/SP when a paging error occurred in the shared segment. ccccccc identifies the type of DIAGNOSE instruction that was being executed by GAM/SP when the error occurred: it is either FINDSYS or LOADSYS. 204 IBM VM/SP System Messages and Codes The processor module appropriate to the filetype was not found. ~Y§tem Action: RC = 28 Execution of the command is terminated. User Action: Correct reissue~e-cemmand. the filetype and EDIT eMS Edit Messages EOF REACHED The following messages are issued by the CMS Editor in response to the EDIT command and its subcommands. nnn LINE(S) CHANGED [, nnn LINE(S) TRUNCATED] Ex£!!nation: A CHANGE subcommand caused nnn lines to be changed and/or nnn lines to be truncated. jxplanatioB: The number of lines beyond the starting line specified in a GETFILE subcommand exceeded the end of the indicated file. The lines from the starting line to the end of the file were inserted in the file. When verification is on, the last line inserted is displayed at the terminal. FILE IS EMPTY An attempt to SAVE or AU~OSAVE a null file was detected. If the subccmmand was PILE, the Editor exits and is erased; if it was SAVE or AUTOSAVE, control returns to edit mode. In either case, the file is not stored on your disk. ~~]!!natioB: ~z~lanation: An automatic save was just performed on the file being edited. (AUTOSAVE) currently FILE NeT FOUND AVAILABLE STORAGE IS NOW FULL Ex~lanati~: The size of the file cannot be increased. Any attempt to add lines produces the message Ne ROOM. Other commands are unaffected. Use the FILE subcommand to store what you have already edited on disk. To continue editing, you may temporarily increase the size cf your virtual machine by issuing the CP command DEFINE, or split the file into two smaller ones. ]z£!anatio~: The file identification specified in a GETFILE subcommand was not found on an auxiliary storage device. GETFILE IS INCOMPLETE ~~l!~!tion: The available storage was exceeded while attempting to execute a GETFILE subcommand. The last line inserted into the file is displayed at the terminal. EDIT: Ex£l!nation: This message indicates entry to edit mode. During initialization, if the file identification specified in the EDIT command is found on disk, this is the first response; otherwise, the file is new and the message NEW FILE: precedes the message EDIT:. This message is also displayed: • When you enter a null line in edit mode. • When you return from mode. CMS subset to edit • If verification is on when you null line in input mode. enter a • If verification is on when subcommand completes execution. a GIVEN STARTING LINE IS BEYOND EOF ~~l!nation: The starting line specified in a GETFILE subcommand points beyond the last line of the indicated file. INPUT: ~ZE!!~!ioB: lines entered of the file. Indicates entry to input mode; at the terminal become part INVALID LINE NUMBER REFERENCE IN STMNT nnnnn ~~E!!B!!iQB: SAVE END ZONE SET TO 72 Ex~laA!tion: The SERIAL subcommand was issued when the zone setting was within the serialization field. The end zone is reset to column 72. This message occurs for VSBASIC files only. The line number referenced in statement nnnnn is invalid (not numeric). The old line number is nnnnn. The RENUM subcommand is terminated by the Editor without renumbering the file. To continue, correct statement DnnnD and reissue the subcommand. INVALID SYNTAX IN STMNT nnnnn jXE1!~atiQ~: EOF: Ex]lanation: The line pointer is positioned after the bottom line of the file or, if the file is empty, after the null line at the top of the file (subject to the setting of the VERIFY subcommand). This message occurs with VSBASIC files only. RENUM cannot convert the line number operand in statement nnnnn because of incorrect language usage. The old line number is nnnnn. The RENUM subcommand is terminated by the Editor. To continue, correct the statement in line nnnnn and reissue the command. ConVersational Monitor System (CMS) Messages 205 EDIT INVALID $name PARAME~ER j!R!~~ion: LIST ]zB!anation: The indicated edit macro was invoked with one or more errors in the subcommand line. LINE xxxxx REFERENCED IN STMNT nnnnn, NOT FCUND Explanation This message occurs for VSBASIC files only. The line number specified as an operand in statement nnnnn was not found. The old line number is nnnnn. The RENUM subcommand is terminated by the Editor. To continue, correct the line number operand xxxxx in statement nnnnn and reissue the command. A nonnumeric character was found in the columns reserved for line numbers. The line pointer identifies the line in error. You should correct or delete the line in error. NOT FOUND ~!R!~nation: The search operand specified in the ALTER, CHANGE, FIND, or lOCATE subcommand was not encountered in the delimited range (current ZONE setting), or before the end of the file was reached. OVERFLCW AT STATEMENT nnnnn £~!~!ion: MAXIMUM LINE NUMBER EXCEEDED EXFl~EatioE: The RENUM subcommand specified values for "strtno" and "incrno" that would result in a line number that exceeds 99999 for VSBASIC files or 99999999 for FREEFORT files. The RENUM subcommand is terminated by the Editor. To continue, reissue RENUM with proper strtno and incrno values. This message is also issued for other serialized files if the line number exceeds 99999. The file must be reserialized. NEVl FILE: ExE!~ng!iQR: The message is issued during Editor initialization if the file identified in the EDIT command is net found on the specified disk. If no filemode was specified with the EDIT command, CMS searches only the A-disk and its extensions. This message occurs with VSBASIC files only. The conversion of the line number operand in statement nnnnn would produce a record exceeding the logical record length. The old line number is nnnnn. The RENUM SUbcommand is terminated by the Editor; to continue, correct the statement at old line numter nnnnn and reissue the sutcommand. READ ERROR - GET PILE IS INCOMELETE I!R!~~~!ig~: An unrecoverable error was encountered during the execution of a GETFILE subcommand. The last line inserted into the file is displayed at the terminal. RECORD LENGTH OF FILE TOO LARGE ~lanation: The file identification of a GETFILE subcommand indicates a file with a record length greater than the file being edited. The GETPILE subcommand is not executed. NO LINES MOVED RENUM MODULE NOT FOUND ~E!gngtiQR: invoked with equal to O. The edit number of macro $MCVE was lines to be moved NO ROOM !!E!anation: An attempt to enter additional lines to a file was detected after the message AVAILABLE STORAGE IS NOW FULL was displayed. Any stacked lines are cleared to avoid multiple error messages or improper subcommand execution seguences. Use the FILE subcommand to store what you have edited so far on disk. To continue editing, you must either split the file into two smaller files or temporarily increase the storage size of your virtual machine via the CP DEFINE STORAGE command. The maximum virtual storage permitted is determined by the MSTOR value in your directory entry. Expla~~: The RENUM subcommand reguires that there be a RENUM mcdule on the system disk. The RENUM subcommand is terminated by the Editor. Your installaticn system programmer must place the RENUM module on the system disk. RENUMBBR LINES Explanatio~: 1. The line number prompter cannot proceed because tbere are no mete numbers between the current line number and the line number of the next line already in the file (that is, they differ by one). In LINEMeD! RIGHT, the user can turn LINlMOD! OFF, issue a SERIAL subcommand, SAVl the file on disk (reseriali~ing it), and finally turn LINEMODE RIGHT on and continue with the editing session. 2. The NON-NUMERIC CHARACTER IN LINE NUMEER CCLUMNS 206 IBM VM/SP System Messages and Codes next line number, 100000000 or EtI~ 100000, is too large. 3. FMODE subcommand specifying an access-mode letter not in the range A-G, S, 1, or Z, or an access-mode number that is grEater than 5. If you are editing a VSBASIC or FREEFORT file, you can use the RENUM subcommand to renumber your file. SET NEi FILENAME AND RETRI !~]1anation: RESERIALIZATION SUPPRESSED During the execution of a SAVE, AUTOSAVE, or FIlE subcommand, an error occurred while altering the name of the CMS work file. You can now institute recovery procedures, since the Editor returns to edit mode. The work file remains. It should be erased, and a different file identification for a subsequent SAVE, AU~OSAVE, or FIlE subcommand should be specified. ]Z~l~~ti2n: Reserializaticn on a SAVE, AUTOSAVE, or FILE subcommand is suppressed when LINEMODE RIGHT is set so that the numbers used during the editing sessicn are retained. To reseria1ize, repeat the SAVE, AUTOSAVE, or FILE with LINEMeDE OFF set. SAVED (See "_SAVED".) STACKED LINES CLEARED SERIALIZATION IS INCOMPLETE ~l!natioB: Multiple subcommands were detected after a failure to increase the file size when the Editor had indicated NO BCOM. This message is also displayed when an abnormal exit from edit mode occurs (to preserve the CMS command environment from stacked EDIT subcommands), or when an error is encountered in executing an edit macro. !!£1~ation: During the execution of a SAVE, AUTOSAVE, or FILE subcommand that is serializing a file, the disk becomes full before the last line is written. The partial file is erased and the user is notified of the condition. SET NEW FILEMODE, OR ENTER SOME SPACE CMS SUBSET AND CLEAR STACKED LINES CLEARED BY $name ~~l!~!ioB: When the named edit macro (such as $MOVE) is invoked, any stacked lines are cleared by the macro before its execution. This message also occurs when an edit macro is issued when the current line pointer is at the top of the file or the end of the file. When an edit macro is issued with the current line pointer at any other point in the file, the message does not occur unless lines are stacked in the console stack. ~lanation: During the execution of a SAVE, RENUM, AUTOSAVE, or FILE subcommand, the disk becomes full before writing the last line of the file. ~he Editor erases the partial file. To continue, either (1) alter the destination of tbe edit file with the FMODE subcommand, or (2) enter CMS subset and erase unneeded files to make more room available. STRING NOT FOUND, NO DELETIONS MADE SET NEW FILEMODE AND RETRI Ex£1~nati2B: An attempt was made to SAVE, AUTOSAVE, or FILE a file on a disk that is read-only or not accessed. lou may reissue the subcommand specifying the filemcde of a read/write disk; or, if you do not have a read/write disk active, you may enter the CMS subset environment by issuing the subcommand CMS, then issue the ACCESS command to gain aCcess to a disk in read/write status, and then return to the edit environment by issuing the RETURN command. If you are using a VSBASIC file and issued a RENUM subcommand, you must access the disk you specified in read/write status for the sUbcommand to operate. The RENUM subcommand is terminated by the Editor without renumbering the file. ~o continue, use the PMODE subcommand tc direct the file to a read/write disk and reissue the RENUM subcommand. This message is also issued if you !lEl~natioB: The specified character string has not been found by the end of the file. No deletions have been made, and the current line pointer remains unchanged. TOF: EXpl!nation: The current line pointer is positioned at the null line at the top of the file. This message appears either after the TOP subcommand has been issued or after any other EDI~ subcommand has positioned the line pointer at the null line at the beginning of the file. TOO ~ANY LINES TO ]l~l~~!ion: ~OVE The $HOVE invoked with the number moved greater than 25. edit macro was of lines to be use Conversational Monitor System (CMS) Messages 201 EDIT TOO MANY LINES TO STACK ExEl~S~: During initialization, the parameter of the STACK subcommand implies a storage requirement in excess of that reserved for the execution of the subcommand. The limit is 25 lines. ZO~E ERROR lxplanat~: The string specified in a CHANGE subcommand is too long for the current zone specification. The file is not changed. TRUNC SET TO 72 ]lR~1iQB: Expla~stion: The SERIAL subcommand was issued and the truncation column was set within the serialization field. The truncation column is reset to column 72. TRUNCATED EX£!SBation: The current line has exceeded the truncation column. If verification is on, the truncated line is displayed, followed by the message INPUT: (if in input mode). Same as ?EDIT:, but the input line is not displayed because the SHORT subcommand is in effect. ~lE~stion: Same as ?EDIT:, but displayed when an invalid edit macro issued and the SHORT subcommand is effect. is is in ?EDIT: ]A£1s~ioB: WRONG FILE FORMAT FOR LINEMODE RIGHT ]zElsnstiQB: The LINEMOD! RIGHi option is not compatible with variable-length files or files that have a fixed record length other than 80. An unrecognizable EDIT subcommand or invalid subcommand operand was encountered. The input line is displayed for inspection. This form is used if the LCNG subcommand is in effect. DMSBWR170S DISK 'mode (cuu) WRONG FILE FORMAT FOR RENUM ~!A~tion: The filetype of the file you are editing is not VSEASIC or FREEFORT, or the Editor detected an invalid line number. For VSEASIC files, the line number must be the first five characters cf the record. For FREEFORT files, the line number must be the first eight characters of the record. The RENUM subcommand is terminated by the Editor without renumbering the file. To continue, correct the line number or filetype and reissue the RENUM subcommand. WRONG FILE FORMAT FOR SERIALIZATION ExElsnation: The SERIAL subcommand was issued for a variable-length file or for a file that does not have a fixed record length of 80. 208 IEM VM/SP System Messages and Codes I IS FULL 11Rl§Bation: CMS issues this message if the output disk becomes full during execution of a FILE, SAVE, RENUM, or AUTOSAVE subcommand becomes full. The subcommand is terminated by the Editor, erases the work file (which is incomplete), and reguests the user to specify a new filemode or make more room on the disk. DEBUG DEBUG Messages INCORRECT DEBUG EXIT For the GO subcommand, this message indicates that the subcommand was issued without aD operand, but an operand was required because the debug environment was entered by issuing the DEBUG command. For the RETURN subcommand, this message indicates that RETURN was nct the Froper subcommand to use, because the debug environment was entered due to a breakpoint, a program or external interrupt, or an unrecoverable error. To exit from the debug environment under these circumstances, issue the GO subcommand (no operand is necessary). Issued by: GO, RETURN INVALID OPERAND For the BREAK subcommand, this message indicates that the breakpoint identification number specified in the first operand is not a decimal number between 0 and 15 inclusive, or the second operand cannot be located in the debug symbol table and is not a valid hexadecimal number. If the second operand is intended to be a symbol, a DEFINE sutcommand must have been previously issued for that symbol; if not, the operand must be a valid hexadecimal storage location. For the DEFINE subcommand, this message indicates that the name specified in the first operand contains all Dumeric characters, the second operand is not a valid hexadecimal number, or the third operand is not a decimal number between 1 and 56 inclusive. For the DUMP subcommand, this message is issued if the address specified by the second operand is less than that specified by the first operand, or if the first or second operands cannot be located in the debug symbol table and are not valid hexadecimal numbers. If either operand is intended to be a symbol, a DEFINE subcommand must previously have been issued for that symboli if not, the operand must specify a valid hexadecimal l·ocation. not CAW, CSW, PSW, or GPR, or the first operand is GPR and the second operand is not a decimal number between 0 and 15 inclusive, or one or more of the hexinfo operands does not contain heXadecimal information. For the STORE subcommand, the first operand cannot be located in the debug symbol table and is not a valid hexadecimal number, or the information specified in the second, third, or fourth operands is not in hexadecimal format. If the first operand is intended to be a symbol, a DEFINE subcommand must have been previously issued for that symbol; if not, the operand must specify a valid hexadecimal storage location. For the X sutcommand, the first oJ;erand cannot be located in the debug symtol table and is not a valid hexadecimal number, or the second operand is not a decimal Dumter between 1 and 56 inclusive. If the first operand is intended to be a symbol, it must have been defined in a previous DElINE subcommand; otherwise, the operand must specify a valid hexadecimal number. Issued by: BREAK, DEFINE, OEIGIN, SET, STeEE, X DUMP, GO, GPB~ INVALID STORAGE ADDRESS For the DEFINE, DUMP, GO, STORE, or X SUbcommand, the sum of the current origin and the hexadecimal location specified in the sutcommand is greater than the user's virtual storage size. If the c~rrent origin size is unknown, reset it to the desired value by issuing the ORIGIN subcommand, and then reissue the subcommand. For the GO sutcommand, this message may also indicate that the address at which execution is to b.gin is not on a halfword boundary (indicating that an operation code is not located at that address) • For the ORIGIN subcommand, the address specified is greater than the user's virtual storage size. Issued by: DEFINE, DUMP, GO, ORIGIN For the GO or ORIGIN subcommand, a specified operand cannot be located in the debug symbol table and is not a valid hexadecimal number. If the operand is intended to be a symbol, a DEFINE subcommand must have been previously issued for that symbol; if not, the operand must specify a valid hexadecimal location. For the GPR subcommand, the operand(s) specified are not decimal numbers between 0 and 15 inclusive, or the second operand is less than the first. INVALID STORAGE REFERENCE The location indicated by the second operand is uneven (not on a halfword boundary) or the sum of the second operand and the current origin value is greater than the user's virtual storage size. If the current origin value is unknown, it may be reset to the desired value by issuing the ORIGlN sutcommand. Issued by: BREAK For the SET subcommand, the first operand is Conversational Monitor System (CMS) Messages 209 DEBUG ORIGIN, HI, PSW, RETURN, SET, STORE, I MISSING OPERAND The user did not enter the m~n~mum number of operands required by the subcommand. Issued by: STORE, X BREAK, DEFINE, GPR, ORIGIN, SET, TOO MANY OPERANDS The user entered more subcommand required. operands than the 16 SIMBOLS ALBEADY DEIINED The debug symbo1 tab1e is full and no new symbols can be defined until the current definitions are cleared by obtaining a new copy of CMS. However, an existing symbol can be assigned to a new storage location by issuing another DEFINE subcommand for that symbol. Issued by: DEFINE Issued by: BREAK, CAW, 210 CSW, tEFINE, GO, GPR, IBM VM/SP System Messages and Codes EXEC eMS Exec Messages ~he CMS EXEC interpreter generates twc error messages, the descriptions of which are found in the "Conversational Monitor System (CMS) Messages" section. DMSEXC001E NO FILENAME SPECIFI!D DMSEXT072E ERROR IN EXEC FIl! error description fn, lINE nn CMS EXEC Messages 211 EXEC EXEC 2 Messages The EXEC 2 interpreter generates three error messages, the descriptions of which are found in the "Conversational Monitor System ~MS) Messages" section. DMSEXE085E ERROR IN fn ft fm, lINE nnn -message DMSEXF175E INVALID EXEC COMMAND DMSEXE255T INSUFFICIENT INTERPRETER 212 S'1CRAGE FOR IEM VM/SP System Messages and Codes EXEC Df!T. Remote Spooling Communications Subsystem (RSCS) Messages VM/SP adds no additional functions to the these messages refer to VM/370 Release 6. Remote Spooling Communications Subsystem (RSCS). 0001 RSCS eVER v, LEV 1, mm/dd/yy) READY 070E I/O ERROR cuu SIOCC cc CCW ccw This message signals the completion of RSCS initialization, including the activation of the AXS and LAX tasks. VER v and LEV 1 specify the version and level of RSCS that is in use. mm/dd/yy specifies the date on which the RSCS in use was generated. Hence, CSW csw SENSE sense ~Elanatiog: Expl~natioB: This message is issued by any task in RSCS that detects an uncorrectatle hardware or system error during the processing of an I/O operation. The causes of such an error vary, depending on the particular device type and command code. !ctiog: The system begins normal processing by accepting files and ccmmands. cuu ~~!Qf cc ~~st~ !ctlQB: Normally, one links are activated at this time. 0011 FREE STORAGE or more nn PAGES csw ]z]1~~tioB: The amount of available storage has increased as the result of normal system processing. ~he new number of available free pages is given as "nn". Syst~ !~tiQB: Normal processing continues. Operator Ac!ioB: You may use this information in deciding whether to activate a previously inactive link. sense ccw 0021 LINK linkid DEACTIVATED EXE1~ation: The link identified by "linkid" has been deactivated as a result of the execution of a previous DRAIN command, or as the result of an orderly shutdown following a terminal line-driver error. The link remains inactive until it is activated again by an explicit ccmmand. !£!!gn: The link's line-driver task is deleted from the system, all storage allocated to the task is made free, and the link table entry is updated. ~B!~ 0031 LINK linkid EXECUTING: (command line text) The RSCS command descrited by (command line text) has been forwarded by a remote station for local execution. The link for the remote station forwarding the command is identified by 'linkid'. - the virtual device address of the I/O device on which the error occurred. - the condition code resulting from the issuing of the SIO command on the device for the operation which was in error. - the composite CSW associated with the operation in error. ~he composite CSW is a logical ORing of the CSW information associated with the SIO or the interrupts from the device while the I/C operation was active. - the sense information associated with the I/O operation in error if the I/O operation ends with unit check set on. - the first CCW of the I/O operation in error if it failed to start, or the last CCW fetched by the channel before the I/O operation terminated with an error indication. aYB!~~ Actio~: The error is logged, and appropriate recovery procedures are taken. The exact effect of the I/O error condition depends on the existing conditions when it occurs. The system may continue processing normally, the link may be autcmatically deactivated, or RSCS may shut down. QE§~tor ActiQB: This message indicates a serious system or hardware error. Call IBM for hardware or system support. Expl~natioB: The operator has not been automatically logged on. The reason may be given in one of the logon failure messages that precedes this message. ~!~natign: ~B!~~ Action: The command is executed, and the resulting response is returned to the originating link, to be sent tack to the remote station. 091T INITIALIZATION FAILURE ~- RSCS SHUTDOiN g~~!~~!ioB: An unrecoverable error occurred during the initial loading of the supervisor components, MSUP, REX, AXS, and LAX. !£!!QB: A virtual storage dump is automatically taken, and a masked-off wait state PSW is loaded, system operation is termina ted. a~B!~~ Remote Spooling Communications Subsystem (RSCS) Messages 213 DMT .QJ2~tor ActiQ!!: serious error. personnel. This message indicates a Notify system support 101I FILE spoo1id ENQUEUED ON LINK 1inkid ~!~~tio~: This message is issued when the file identified by "spoo1id" has arrived at the RSCS virtual machine, and has been successfully accepted and engueued on the link identified by "linkid". This message is also issued when a previously pending file is accepted after a tag slot has become available. ~st~ !£!!Q!!: The newly accepted file is made available to the link's line driver for future transmission. If the line driver is waiting for a file to transmit, it is notified that the new file is available. locid1 - the ID of the location of the file's originator. name1 - the name of the file originator's system or device at the rEmote location. mm/dd/yy - the date of the file'S origination at the remote location. hh:mm:ss - the time of day of the file'S origination at the remote location. !1§!~! !£!iQ!!: The virtual output device used to process the file is detached and normal processing continues. .Q..E~lli Action: None. 1051 FILE spoolid PURGED !!E!!~~: The file identified by "spoolid" has been purged from the system as a result of normal processing. !fi io!!: The file's virtual storage tag is dequeued and its slot is freed. If another file is pending, it is accepted. All system tables are updated, and normal processing continqes. ~1§!§! 1021 FILE spoo1id PENDING FOB LINK linkid EXE!~!!S!i2!!: The file identified by "spoolid" has arrived at the BSCS virtual machine, but has not been engueued cn the link "linkid" to which it is addressed, because no tag slot is available. ~1~! ActiQ!!: The link's pending count is incremented, and the file is accepted when a tag slot becomes available. 103E FILE spoolid REJECTED DESTINATION ADDRESS INVALID ~!£!!natiQ!!: The file identified by "spoolid" has arrived at the RSCS virtual machine with a missing or invalid destination address i~ the file's tag. ~st~ !£!io!!: The improperly addressed file is automatically purged from the system, and the originating virtual machine user is notified. gE~ !£!iQ!!: The file to be transmitted must be regenerated with a correct destination address in the file tag setting. 1061 FILE spoolid MISSING linkid DEQUEUED FBOM LINK JAElanation: The file identified by IIspoolid ll could not be located in the BSeS virtual machine spool input file queue during an attempt to open the file for the link identified by "linkid". This situation usually results from users retrieving files that had previously been spooled to the BSCS virtual machine and accepted by the spool file access routine. System ~!!: The tile's virtual storage tag is dequeued and its slot is fI;eed. if another file is pending, it is accepted. The link table entry is updated, and normal processing continues. QE$~!~2~ ActiQ!: No action is necessary. This message does not indicate an error condition. 1071 nn PENDING FILES FOB LINK +inkid MISSING ~xplanatio!!: ExElanation: A file has been received from a remote location, acknowledged, written to the VM/370 spool system, closed, and spooled to the local virtual machine to which the file was addressed. A number (nn) of pending files for the link identified by 'linkid' have been found to be missing from the BSCS virtual machine spool input queue during an attempt to accept a pending file. This situation usually results from users retrieving files that had been previously spooled to the BSCS virtual machine and left pending on the link. userid2 ~ystem 1041 FILE SPOOLED TO userid2 (name1) mm/dd/yy hh:mm:ss 214 OBG 10cid1 - the ID of the local virtual machine to which the file has been spooled. IBM VM/SP System Messages and Codes A9tion: The link table entry is updated to reflect the proper pending file status, and normal processing continues. QR~~ Action: No action is necessary. This message-does not indicate an error condition. • lOSE SYSTEM ERROR READING SFCOL FILE spoolid EXR!!A!!!2B: A return code reflecting a VM/370 system error has been received in response to a read to the file identified by "spoolid". ~l§~ !£!~QB: The error is logged and the failing operation is retried up to ten times. If a retry is successful, normal processing continues. If the error persists, an attempt is made to purge the file and a message to that effect is issued to the operator and to the originating virtual machine. Actio!!: This message indicates a VM/370 system error. Call your system support personnel. QE.!.!.!to~ 1411 LINE vaddr READY linkid FOR CONNECTION TO LINK Explg~tiQB: This message is issued by a line driver to inform the operator that the line identified by "vaddr" is being enabled for communications processing to the link identified by "linkid". Normally, this is the first message issued ty a line driver after link activation, and it may be issued during active processing after a line becomes disabled. ~Y§!~! Act~2B: Normal link processing begins. If a. file gueue exists on the link, and if there are files eligible for transmission, the file transmission begins automatically. File receiving from the remote station begins automatically. 1431 LINK linkid LINE vaddr DISCONNECTED E1R!g~g!io!!: The virtual line port address identified by "vaddr" and associated with the active link identified by "linkid" was connected and is now disconnected. This may be the result either of an apparent line disconnection due to line errors, or of the remote station hanging up, or of the execution of a disabling seguence by the local line driver. This message does not mean that the associated link has been deactivated, but the message is normally issued during the process of link deactivation. ~I§!~ ActioB: If the link is not in the process of deactivating, an attempt is made to re-establish the line connection. File processing is halted on the link until a line connection is reestablished. 1441 RECEIVING: FILE locid2 (userid2) FROM locid1 (name1) FOR E~!g!!gtio!!: ActiQB: The line driver begins an enable operation on the line and waits for completion, signaling a completed connection. If the line identified by "vaddr" is a nonswitched line, the connection completes automatically. Normal processing continues. Reception of a new file from the remote location identified by "locid1" and the system or device name at that location identified by "name1" (if any) has begun. The file being received is destined for the location identified by "locid2" and the virtual machine at that location identified by "userid2" (if any). QE~2~ ~Y§!~ !ctio~: ~lst~! Acti2B: No response is needed if the line identified by "vaddr" is a nonswitched line, or if it is a switched line with auto-answer and the remote station is to complete the connection. If the line is a switched line, the operator should ensure that the necessary steps are taken to complete the connection to the link identified by "linkid" (for example, manual dialing of the associated data-phone) • 1421 LINK linkid LINE vaddr CONNECTED Explanation: This message signals completion of the line connection for the link identified by "linkid" on the line port address identified ty "vaddr". This message is issued automatically when a nonswitched line is enabled, and it is issued when a connection is completed for a switched line. This message does not necessarily mean that any successful interaction with the remote station has taken place on the connected line. File processing and the new file is written to spool system as it is received. 1451 RECEIVED: FILE FROM locid2 (userid2) locid1 continues, the VM/370 (name1) FOR E1R!!!!gtioB: A new file has been completely received and acknowledged from the remote location identified by "locid1" and the system or device at that location named "name1". The file received is destined for the location identified by "locid2" and the virtual machine at that location identified by "userid2". ~l§!~ Action: If the file is destined for the local location, and for a particular virtual machine at the location, it is automatically spooled to that virtual machine. Normal file processing continues. Operator ~QB: None. Remote Spooling Communications Subsystem (RSCS) Messages 215 DMT 1461 SENPING: FILE nnnnnn spoolid ~N LINK linkid, REC lJR!!R!!1ga: Transmission of th~ file identified by "spoolid" on the link identified by "linkid" has begun during normal file processing. The idEntified file contains nnnnnn records, and the file has become active. ~~§!~ !£!iOB: Transmission of the file continues to completion, or until it is stopped by some other event. 1601 LINE vaddr DISABLED FOR LINK lin kid EXplABation: Line processing by the link identified by "linkid" on the line identified by "vaddr" has been terminated, and the line has been disconnected if it is a switched line. This message may be issued during normal processing as a result of a spontaneous line disconnection. It is always issued during the process of link deactivation. As!iQB: If link deactivation is in process, it continues normally. Otherwise, an attempt is made to reconnect the line. File processing for the link is suspended. ~~!~ 1471 SENT: FILE spoolid ON LINK linkid ~~]laBatl2B: Transmission of file id~ntified by "spoolid" the active on the link identified by "linkid" has been successfully completed and acknowledged by the remote station. ~§!~! Ac!i2B: Disposition of the identified file follows, according to the status of the file. ~he file may be purged, repeated, or held fer future retransmission. Normal link processing continues. 1701 FROM linkid: (MSG message text) !~Rlg~tion: The character string included in the message as (MSG message text)" has been received on the link identified by 'linkid' as the operand of a remote MSG command. ~st~! A£!i2B: continues. Normal link processing Action: A response may suggested by the-MSG character string. g~!~ 1491 LINK linkid LINE ACTIVITY: nnn; T~OUTS= ppp be !OT= mmm; ERRS= 190E INVALID SPOOL BLOCK FORMAT ON FILE spoolid ~!El~nation: ~~R!!~tioB: mmm Syst~ Action: The error condition is file is logged, ~e identified automatically purged from the system, and link processing continues. This message is issued occasionally when trace mode has been set for the link identified by "linkid". The message is issued when one of the trace values reaches the predefined incremental threshold, depending on the active trace option setting!' nnn ppp - the total number of communication line transactions that have taken place since the last similar message was issued, or since the trace mode was set. - the total numter of communication line transactions that have ended with a line error indication since the last similar message was issued, or since the trace mode was set .. - the total number of time-outs that have occurred wbile waiting for response from the remote station since the last similar message was issued, or since the trace mode was set. A time-out is not counted as a line transaction. ~§!~ !£!!~: Normal processing continues. VM/370 spool control or data information associated with the file identified by "spoolid" has been found to be in error at the local installation. g]~!!tO! !cti~: This message indicates a system error at the local installation. Notify system support personnel. 2001 RSCS Expl~ion: A null line was entered as a console command. A null line is a line that contains no characters. If a line containing characters is edited to a null line, this message is not issued, and another read is automatically started on the console. Syst~ Acti2B: Normal processing continues. 201E INVALID COMMAND command Q.E~um Acti2B: Depending on the data reported in the message, you may cboose to intervene with a command to deactivate the link, or you may try to hang UP the line and reestablish it to reinitialize communication. 216 IBM VM/SP System Messages and codes j!Rl!~tion: The specified command is not a valid RSCS command. ~I§~ Action: The command is ignored, and normal processing continues. D"~ Operat~ !ctiQB: Correct and reissuE the command. Qpg~A!2I Action: Correct and reissuE the command. 202E INVALID LINK linkid 207E CONFLICTING OPTION keyword option Explanation: The specified linkid was not in the proper format for RSCS link IDs (one to eight alphameric characters). ~st~ ActiQB: The command is ignored, and normal processing continues. IJR!Anation: The specified keyword and option conflict. Another keyword or keyword-and-option combination in thE same command may have invalidated the specified keyword-and-option combination. ~I§!§'! operat£I !£tiQB: Reissue the with a valid linkid. command line Action: The command is ignored, and normal processing continues. Qp§Is!2I command. 203E INVALID SPOOL FILE ID spoolid Explanation: The specified spoolid was not in the proper format for V"/370 spool file IDs (one to four decimal digits from 1 through 9910). !£!ion: Correct and reissuE the 208E INVALID USER ID userid ExplanatioB: The specified userid is invalid. virtual machine ~st~~ ActiQB: The command is ignored, and normal processing continues. ~tem Action: The command is ignored, and normal processing continues. QR~to~ !£tiQB: Reissue the command with a valid spoolid. £perator ActiQB: Reissue the command with a valid userid. 204E INVALID KEYWORD keyword 3001 ACCEPTED BY TASK task ExplanA!ion: The specifiEd keyword is not a valid keyword for the command issued. The correct format of RSCS console commands, including valid keywords, can be found in the V8/370 R~motg ~QQling CO~~YBi£st!QB§ Subsyst~~ (RS£~) Use~ QYi.Q~. Syste~ ActiQB: The command is ignored, and normal processing continues. Operator ActiQB: Reissue the command with a valid keyword. 205E CONFLICTING KEYWORD keyword EXRlanation: The specified keyword was used in an invalid way. It may havE been entered more than once in the same command line, or it may conflict with another keyword. ~§tem ActiQB: The command is ignored, and normal processing continues. Opera!~~ ActiQB: Correct and reissue the command. 206E INVALID OPTION keyword option Explanation: The specified keyword and option combination is not a valid combination for the command issued. The format of RSCS commands, including valid keyword-and-option combinations, can be found in the !~1~ ~~~ §Rooling Communication§ ~!2syste.! (RSCS) ~.£!§ Guide. ~!~ ActiQB: The command is ignored, and normal processing continues. J!RlsBStion: The preceding console command has been processed by the CMX syntax scanner and first level semantic processor, and a command element has been built. That command element has been made available to the task named "task", and that task has accepted the command element for second level semantic processing. §.Y..§!§.! Action: Command semantic processing continues at the task named "task". Further response to the command is issued from that task. The command processor is another ccnsole then ready to accept command. 301E REJECTED BY ACTIVE TASK task ~- PREVIOUS COMMAND jxplana!ioB: The preceding console command has been processed by the CMI syntax scanner and first level semantic processor. A command element was built and made available to the task named 'task', tut that task was unable to accept the ccmmand element for further processing because a previously issued command is still being processed. §I§tem Action: The command execution is terminated, the command has no effect, and normal processing continues. Operator Acti~: Reissue the command when the active command processing has coml'leted. Remote Spooling Communications Subsystem (RSCS) Messages 217 DMT ~l§!g! 302E LINK linkid IS NOT DEFINED AQ!iQB: response. ExR1~1Qn: The specified linkid is syntactically valid, but no such link is defined with that ID and the command issued requires a defined linkid. Syst~ !£!1QB: The command execution is terminated, the command has no effect, and normal processing continues. Operato~ ActiQB: Check to see if the linkid specified is valid. If it was incorrectly typed, reissue the ccmmand with a correct linkid. If it was correctly typed, you must define the specified link before the command can be executed. 303E LINK ~inkid Explanation: The link identified by "linkid" was specified in the preceding command, but the link is inactive and the command requires specificaticn of an active link. Syst~m !£!i2B: The command execution is terminated, the command has no effect, and normal processing continues. !£tiQn: Activate the link and reissue the command. system sFecified 304E REJECTED BY TASK task -- NOT RECEIVING lZE!sBatiQB: Processing of the preceding command could not be completed, because the second level processing task named "task" failed to accept the command service reguest. waits for a "ygI A£!io,!!: Enter "yes or "no." If you enter "yes~, message DMTINI409R is issued, prompting you to specify the cylinder on the system disk on which the RSCS nucleus is to be written. If you enter "no", the rema1n1ng questicns in generating a new RSCS nucleus are skipped and control is passed to the RSCS initialization routine. A copy of the RSCS nucleus is not written onto disk. If you fail to enter the message either "yes" or "no", DMTINI481E INVALID REFLY OR "NO" IS NOT ACTIVE QBeratQ~ The ANS~IR "YES" is issued. Message DMTINI407R is reissued and you may enter a valid response. 409R NUCLEUS CYL AtDRESS = nnn ~.!.E!sl!SlliB: "nnn" designates the cylinder on the device entered in response to message DMTINI406R on which the BSCS nucleus is to be written. nnn must be tetween 001 and m-1, where ~ equals the number of cylinders on the disk, the cylinders on a disk being numberEd frou 0 to g~. nnn must be entered in decimal. System Actio,!!: If you do not enter a valid decimal cylinder number, the message DMTINI480E INVALID CYLINDER NUMBER REENTER is issued, message DMTINI409R is reissued, and you may enter a valid cylinder number. ~~~m !ctiQB: The command is ignored, and normal processing continues. QE~ratQ~ !£1iQB: Repeated occurrences of this message indicate a system error. Notify system support personnel. If the cylinder specified is not greater than the number of cylinders already in use on the device (as indicated in the Master File Directory), then the message DMTINI483E NUCLEUS WILL OVERLAY FILES RECOMPUTE 402T IPL DEVICE READ I/O ERROR Explanation: An uncorrectatle I/O error occurred while reading the RSCS nucleus from a DASD. ~stem with a INI') • !£tiQB: A wait state PS~ is loaded wait state code of X'40C9D5C9' (C' User Action: Call your installation support perso~ 407R REWRITE THE NUCLEUS? {lESI~O} Explanatio~: This message prompts you to specify whether or not the copy of the RSCS nucleus is to be written ontc disk. 218 IBM VM/SP System Messages and Codes is issued. Message DMTINI409R is reissued. You may respond with a larger cylinder number, or IFL the RSCS system and format the specified IFL device with the RECOMP option. Once the nucleus cylinder address accepted, message DMTINI410R is issued. ..y§~~ A£!i2'!!: address. Enter a valid is cylinder 410R ILSO IFL CYLINDER 01 (YESINO) JAplanation: The initial IPL text is always written on the same cylinder as the RSCS nucleus, that is, the cylinder designated in response to message DMTINI409R. (~he D!!T initial IPL text is a tootsttap pxogram that reads in the nucleus from the designated cylinder.) If it is not also written on cylinder 0, you must entEr the cylinder number whenever an IPL is issued for the system being generated. System ~: If you do not enter "yes" or "no", the message DMTINI~81E INVALID REPLY OR "NO" - ANSWER "YES" .§lli!U! ActigB,: Message DftTINI410R is reissued. ]~ DMTINI407R Action: See DMTINI407R or DMTINI410R. 482E S1STEM DISK - REENTER Explanation: Either the device is Dot currently defined, it is not in read/write status, or it is an unsupported device type. is issued. Message DMTINI~10R is xeissued and you may enter a valid response. System Acti,Q1!: xeissued. If you answer "yes," the initial IPL text is written on cylinder 0 as well as on the cylinder designated in response to message ]~ Message DMTINIQ06R is Action: See DMTINI406R. DMTINI~09R. 483E NUCLEUS WILL OVERLAY eMS FILES - RECO!!POTE If you answer "no," the initial IPL text is written only on the cylindex designated in response to message DMTINlq09R. ]§!&: ActioB,: Enter "yes" or "no." 11£!!~!iga: The specified nucleus cylinder number was net greatex than the numter of cylinders indicated 'in the Master File Directory for the IPL device. .§l§t~.!!! ~31S xEissued. IPL DEVICE WRITE I/O ERROR An uncorrectatle I/O occurred while writing the nucleus. l!~lanation: error System As!!gB,: The system continues as if the user had responded "no" to DMTINIQ07R. User Action: Make sure that the nucleus cylinder-iUiber is not laxgex than the size of the disk. If it is, perform an IFL and specify the correct cylindex numter. If it is not, call your installation support personnel. Action: Message DMTINI409R is ]§!~ Action: Respond to DMTINI409R with a larger cylinder number or IPL RSCS and format the specified IPL device with the RECOMP option. 5101 FILE spoolid EACKSPACED The file identified by "spoolid" has been backspaced according to the request in a preceding command. )!E1!~i2n: .§l§!§~ A£!ig~: File transmission continues, teginning from the new file position. q79E INVALID DEVICE ADDRESS - REENTER Exslanatio~: The device addxESS entexed was specified incorrectly; that is, it is not a valid hexadecimal character or is Dot in the range of X'001' to X'6FF'. Syst~ }£tig!: Message DMTINIQ08R is User Action: See DMTINIQOaR. qaOE INVALID CYLINDER NUMEER - REENTER System Action: reissued. ~ Message A command was issued that operates on a file being actively transmitted on the link identified by "linkid", but no file was being actively txansmitted on the link. ~lanat~: reissued. Explanation: The value entered valid decimal number. 511E NO FILE ACTIVE ON LINK linkid !£!ig!: Normal link processing continues, and the command has no effect. ~ystem was not DMTINIQ09R a is 5201 FILE spoolid CHANGED Action: See DMTINIQ09R. qa1B INVALID REPLY - ANSWER "YES" OR "NO" Exslanation: The only valid response to the query is "yes" or "no". Neither was entered. Explanation: The file identified by "spoolid" has been altered as requested 111 the processing of the preceding cemmand. The new file status remains in effect until it' is changed again through an explicit request. '- Remote SpOOling Communications Subsystem (RSCS) Messages 219 DMT ~stem Actio!!: All appropriate action implied by the changed status is performed. This might include reordering a link queue if a file priority was changed, notifying a waiting line driver if a file class was changed, and so on. Ncrmal processing continues. QE!!g!~ Syste~ Actio!!: The preceding command has no effect, and normal processing continues. Operator Action: If you wish, you can deactivate the file by means of a PLOSH command with the HOLD operand, and reissue the command when that has been accomplished. Acti.Q'!!: None. 5211 FILE spoolid HELD FOR LINK linkid EX.E!.SBation: The file identified by 'spoolid' has been placed in hold status as the result of processing of the preceding command. The file remains in hold status and is not transmitted until it is explicitly removed from hold status by a command. ~~st!!~ Acti.Q'!!: The file's virtual storage tag is updated, and normal processing continues. 525E FILE spoolid ACTION TAKEN IS FOR LINK linkid NO Ex~anat~.Q'!!: The file identified by "spoolid" is enqueued on the link identified by "linkid", which is different from the linkid specified in the preceding command. ~I§1~~ !£~~.Q'!!: The action requested in the preceding command is not performed, and normal processing continues. ~pera!.Q~ !£!~.Q'!!: verify that the specified spool file id and link id are correct. If an error is found, reissue the preceding command. 5221 FILE spoolid RELEASED FOR LINK linkid Fxplanat~on: The file identified by "spoolid" and enqueued on the link identified by "linkid" has been released from hold status as a result of the processing of the preceding command. The file is now eligible for transmission on the link. System ActiQ'!!: The file's virtual storage tag is updated, and the link's line driver is asynchronously notified of the file's availability for transmission if the line driver had been waiting for a file to transmit. Normal processing continues. 5231 LINK linkid QUEUE REORDERED Ex~!~nat~.Qn: The file tag queue in RSCS virtual storage for the link identified by "linkid" has been reordered in response to execution of a command. The new crder of the queue defines the order of file transmission on the link. ~~st~m Ac!!Q.B: ~he files reordered to the beginning of the queue are automatically given a priority of zero (highest), and normal processing continues. 524E FILE spoolid ACTIVE -- NO ACTION TAKEN EXE!s~tion: The file identified by "spoolid" is actively being read and transmitted on a link, and the action requested in the preceding command cannot be performed on active files. 526E FILE spoolid NOT FOUND -- NO ACTION TAKEN l!E!~.!!~tio.!!: The file identified by "spoolid" has not been accepted and enqueued by RSCS. The action reguested by the preceding command could not be performed. ~1Btem Action: The preceding command has no effect, and normal processing continues. QE~f~!.Q~ !£!~£B: Verify the spool file ID used in the preceding command. If it was incorrect, the command may be reissued with a correct spool file ide If it was correct, and the file is pending at the RSCS virtual machine, the file may be manipulated through the use of VM/370 spooling commands. 5301 COMMAND FORWARDED ON LINK linkid l~snation: In response to a command, a character string has been transmitted as a remote command on the link identified by "linkid". .2.Y.2!~ Act!.Qn: continues. IBM VM/SP System Messages and Codes link processing 5401 NEW LINK linkid DEFINED ~lanatio.!!: The link identified by "linkid" is now defined as the result of command processing, according to the specified keyword options. ~1§tem 220 Normal !£tion: The newly defined link may Dl!T have spool files enqueued on automatically, and can be activated begin remote processing. it to 5501 LINK linkid NOW DELETED ~~E!~~~ion: Q]~fgto~ ActiQ'!!: Users can begin to address files to the newly defined link for future transmission. 5411 LINK linkid REDEFINEB Ex]lanatiQB: The previously defined link, identified by "linkid", has had its definition changed as the result of command processing, according to the specified keyword options. The previously defined link, identified by "linkid", is now temporarily deleted as a result of command processing. ~~~ Action: Spool files addressed to the deleted link's location ID are no longer accepted, and are rejected as invalidly addressed. The deleted link can no longer 1:e activated. Q~I~!QI !£~~QB: Users can no address files to the deleted link. longer 551E LINK linkid ACTIVE -- NOT DELETED ~st~~ ActiQ'!!: The changes in the link definition become effective immediately. 542E LINK linkid ACTIVE -- NOT REDEFINED ~!~atio,!!: An attempt was made to temporarily delete the link identified by "linkid" from the list of valid linkids (via the RSCS DELETE command). The attempt was unsuccessful because the specified link was active at the time of command processing. Ex]1~tion: The previously defined link, identified by "linkid", has not been changed because the link was active at the time of command processing. Action: The command execution is terminated, the command has no effect, and normal processing continues. ~yst~~ QE~rator ActiQn: Reissue the command after the link has been deactivated. 543E LINK linkid REACHED NOT DEFINED LINK LIMIT An attempt was made to define but the maximum allowable a new link, number of defined links had already been reached. !!li~tiQB: System Actio,!!: The link remains defined and active, the command has no effect, and normal processing continues~ g]~!~~QI Action: Reissue the the link is-deactivated. command when 552E LINK linkid HAS A PILE QUEUE -- NOT DELETED was made to An attempt 1ll1anatio,!!: temporarily delete the link identified by 'lhe "linkid" through a console command. because the attempt was unsuccessful least one file specified link had at enqueued on it at the time of command processing. ~~~ ActiO,!!: The command execution is terminated, the command has no effect, and normal processing continues. ~st~ Action: The link remains defined, the command has no effect, and normal processing continues. Qp~I~!QI Q]eratQI Actio,!!: Check the command line to see if it was accurately typed. If an existing link definition was to have been altered, correct and reissue the command. If a new link was to be defined, another link must be temporarily deleted from the list of valid linkids (via the RSCS DELETE command) before the command can be successfully retried. 544E LINK linkid SPECIFIED NOT DEFINED TYPE NOT ExplanatiQB: The preceding DEFINE command failed because a default line driver type was not specified. Action: Eefore the link can be deleted, al~files enqueued on it and pending for it must be purged, either by ccnsole command execution or by normal file transmission. 5601 RSCS DISCONNECTING machine Explanation: The RSCS virtual console is disconnected as a result of command execution. If an alternate virtual to receive BSCS machine was specified machine output messages, that virtual messages begins receiving the console through the VM/370 MSG fUnction. If no alternate virtual machine was specified to receive RSCS console messages, those messages are discarded. ~st~ !£iiQB: The command is ignored, and normal processing continues. Syst~ Actio!!: RSCS continues processing normally without a main operator console. Operator !ctiQB: Reissue the command, specifying a default line driver type. Q~rator Action: machine console issuing a console The RSCS main virtual can be reinstated by attention and performing Remote Spooling Communications Subsystem (RSCS) Messages 221 DMT the logon routine. 561E USERID userid NOT RECEIVING Ex£!~tion: An attempt has been made to disconnect the main RSCS virtual cperator console with a secondary virtual machine ID identified by "userid" specified to receive RSCS console output messages. The specified virtual machine either was not receiving messages or was not logged on at the time of command processing. from the system, or the file may be held for future retransmission. The next copy of the file may begin transmission if multiple copies remain and ALL was not specified. Normal file ~rocessing continues. ~rator !£ti~: None. 5a1E FILE spoolid NOT ACTIVE by The file identified "spoolid" was not active when a command was processed that specified that file, and the command requires an active file as its object. ~~l~~tioB: ~Ist~ !ctioB: The command processing is terminated, the command has no effect, and normal processing continues. QBerator Action: The command can be reissued with---a-different virtual machine ID specified, or with no virtual machine It specified. The same virtual machine ID can be specified after it has been logged on and set to receive messages. ~l§te~ !ction: The command has no effect, and normal link processing continues. Actim.!: Check the status of the the QUERY FIL! named file by issuing command. .Q'p~'!;~~Q'!; 5701 LINK linkid NOW SET TO DEACTIVATE Expl~tion: In response to the DRAIN command, the link identified by 'linkid' has set drain mode and is deactivated. If the RSCS operator issues the START command before the link is deactivated, processing continues on the link. ~st~ !£~ion: The line driver takes appropriate action to quiesce line activity. This includes the finishing of transmission for an active file if one exists, and it may include the signaling to the remote station of an imFending termination. No new files are activated while the link is in drain mode. When line activity is quiesced, the link is deactivated. 590I LINK linkid RESUMING FILE TRANSFER ]~.pl~~~ioB: The active link identified by "linkid" was in hold status, and has been removed from hold status in response to command processing. El§te~ Acti~B: File transmission on the identified link resumes immediately if the line is connected and there is a file eligible for transmission enqueued on the link. Operator ActiQB: None. 591E LINK linkid NOT IN HOLD STATUS Operator Acti2B: None. identified by The link "linkid" was not in hold status when a command was processed that requested that the link leave hold status. ~~.E.!anatioB: 571E LINK linkid ALREADY SET TO DEACTIVATE Ex£!anation: The link identified by "linkid" was in drain mode when it received a new command to deactivate. EI§!~~ Acti~~: The command is ignored, and normal link processing continues. ~Ist~~ !ctiQB: The line driver continues the deactivation process, and the ccmmand has no effect. 600I FILE spoolid FORWARD SPACED 5aOI FILE spoolid PROCESSING TERMINATED Explanation: In response to the FLUSH command, transmission of the active file identified by "spoolid" was terminated before the completion of file processing. System ActioB: Disposition of the identified file is made according to the status of the file. The file may be purged 222 IBM VM/SP System Messages and Codes ]xplanatioB: The file identified "spoolid" has been forward spaced requested by a preceding command. ~I§!~~ by as ActioB: File transmission continues, beginning from the new file position. 6101 LINK linkid TO SUSPEND FILE TRANSMISSION 6511 LINK linkid INACTIVE Explanation: The link identified by "linkid" has entered hold status. File transmission has not been suspended because at the time of command processing a file was being actively transmitted, and the NOW option was not specified. ~~i2B: This message is issued in response to a QUERY linkid STAT command. The link identified by "linkid" was not active at the time the command was processed. ~st~~ ActiQB: The link remains in hold status. File transmission is suspended when the processing of the active file is complete. 6521 6111 LINK linkid FILE TRANSMISSION SUSPENDED Ex.plgnati,Q.!!: The link identified by "linkid" has entered hold status, and file transmission has been halted as a result of command processing. Either no file was being actively transmitted at the time of command processing, or the link had teen in hold status and its active file transmission has completed, or an active file was being transmitted and the NOW operand was specified. ~Y§!~~ Action: The link remains in hold status, file transmission remains suspended, until the link is explicitly freed from hold status. If active file transmission was interrupted, the transmission of the active file resumes from the point at which transmission was interrupted when the link is removed from hold status. The link continues to process files received from the remote station normally while in HOLD status. -ana-- LINK linkid ACTIVE task type vaddr {HOI NOH) (DRINOD) {TRAITBEINOT} Q=a P=n ExplgBS!i~.B: This message is issued in response to a QUERY linkid STAT command. The link identified by "linkid" was active at the time the command was processed. task type vaddr c HO NOH DR NOD TRA TRE 612E LINK linkid ALREADY IN HOLD STA~US NOT ~!'planation: The active link identified by "linkid" was in hold status when it received a new command to enter hold status, with the same options specified as in the preceding command which caused the link to enter HOLD status. c m n - is the task name of the line driver task. is the ID of the line driver in use by the active link. - is the virtual device address of the line port in use by the active link. - is the class or classes of files that may be processed by the active link. indicates that the active link is in hold status. indicates that the active link is not in hold status. indicates that the active link is in the process of draining, and will terminate when line activity is quiesced. - indicates that the active link is not in the process of draining. indicates that the active link is tracing all line activity. indicates that the active link is tracing line errors. indicates that the active link is not tracing line errors or activi ty. - is the number of files accepted and enqueued for transmission on the link. - is the number o£ files pending but not yet accepted for the active link. ~~stem Action: The link remains in HOLD status, and~e command has no effect. 6401 nn FILE(S) PURGED ON LINK linkid Action: None. 6531 LINK linkid DEFAULT task type vaddr c R=m ExE1gnatign: The number of files denoted by "nn" that were enqueued on the link specified by "linkid" have been purged from the system in response to a PURGE command. ~stem ~l§!~! Actio]!: The "file(s)" virtual storage tags are dequeued and the tag slots are freed. The link table is updated, and pending files are accepted if any exist. Explanation: This message is issued in response to a QUERY linkid DEl command. The link identified by "linkid" was defined at the time o£ command processing, and the default attributes listed in the message pertain to that definition. The message does not indicate whether the link was active or inactive at the time of command processing, and the default attributes listed may be di£ferent from those actually in use with the link if it was active. Remote Spooling CommUnications Subsystem (RSCS) Messages 223 DMT task - the default task name to be associated with the defined link's line driver task when the link is activated. - the ID of the default line driver defined for the link. - the default virtual device address of a line Fort to be used by the link when it is activated. - the default class or classes of files that can be processed by the link when it is active. - the number of virtual storage file tag slots reserved for exclusive use by this link. type vaddr c m 6601 FILE spoolid INACTIVE ON LINK linkid A!E!gnation: This message is issued in response to a QUERY FILE "spoolid" S~AT command. At the time of command processing, the file identified by "spoolid" was inactive, and was enqueued for transmission on the link identified by "linkid". ~y§!~~ Jctig~: None. Q~~g!Q! !cti~n: Syst~~ None. Action: None. 6611 FILE spoolid ACTIVE ON LINK linkid QE~~gto~ Ac!ion: None. ~~E!!ng!ign: 6541 LINK linkid Q=m P=n jz~!snstion: This message is issued in response to a QUERY linkid QUEUE command. The status of the file queue for the link identified by "linkid" is described. m n This message is issued in response to a QUERY FILE spoolid STAT command. At the time of command processing, the file identified by "spoolid" va, active, and was being transmitted on the link identified by "linkid". ~~§!ru!! - the number of files accepted and enqueued for transmission on the link. - the number of files pending but not yet accepted for the active link. §~ste~ Jctio~: An additional message (DMTCMX655I) is issued for each file accepted and enqueued on the link, describing the status of each such file. !ctign: None. Q~~~to~ 6621 FILE spoolid ORG locid1 userid1 hh:mm:ss TO locid2 userid2 This message is in response to the RSCS command QUERY FILE spoolid. The RSCS control-related attributes ot the file identified by 'spoolid' are described. userid1 CL a PR mm REC A message of this form is issued for each file accepted and engueued for transmission on the link sFecified by 'linkid' in the preceding QUERY linkid QUEUE command. ~~lanation: spoolid - the VM/370 spool file ID for the file to be described. locid - the destination location ID to which the originating user addressed the file. userid - the destination virtual machine ID (if any) to which the originating user addressed the file. a - the spool file class. mm - the file's current transmission priority. nnnnnn - the number of records in the file. A - indicates that the described file is active. I - indicates that thE described file is inactive. ~~~: This message is each file in the link queue. 224 issued for IBM VM/SP System Messages and Codes mm/dd/yy ~~!!~lio!: locid1 6551 FILE spoolid locid userid nnnnnn {A I I} !g!ion: None. mm/dd/yy hh:mm:ss locid2 userid2 ~ystem - the location ID of the location at which the file originated. - the virtual machine ID of the originator of the file. - the file creation datE~ - the file creation time of day. the destination location ID to which the originating user addressed the file. the destination virtual machine ID (if any) to which the originating user addressed the file. Action: None. Qperator .!9.!ign: None. 6631 FILE spoolid PR mm CL a CO distcode, NA {fn ftldsnam~ nn {HOI NOH} DI AlRlg!!lion: This message is issued in response to the CP command, QUERY FILES spoolid. The VM/370 spool system-related attributes of the file identified by "spoolid" are described. mm a nn - the file's transmission priority. - the file's spool file class. the number of copies of the file requested by the file creator. DMT HO indicates that the file is in hold status. NOH indicates that the file is not in hold status. distcode - the file's distribution code. fn ft - the file's filename filetype. dsname - the file's data set name. 6721 HO LINK ACTIVE !xpl~io~: This message is issued in response to a QUERY SYSTEM ACTIVE command. No link defined in the RSCS facility was active at the time of command processing. §l§!~ Action: None. Q]2!..n!QJ; Acti~: None. 6731 HO LINK DEFINED 66qE FILE spoolid NOT FOUND ~~~n: ~~lanation: This message is issued in response to a QUERY FILE spoolid command. The file identified by "spoolid" could not be found in the Rses virtual storage gueues, meaning either that the file is not owned by the RSCS virtual machine, or that the file is pending and has not yet been accepted by RSCS. This message is issued in response to a QUERY S1STEM command. No link was defined in the Rses facility at the time of command processing. 7001 ACTIVATING LINK linkid task type vaddr c ~.Y§tn Action: None. A!plg~tion: Q]~!Ato£ A£!~g~: Verify that the spool file ID was correctly typed. If it was not, retry the command with the correct spool file ID. If it was correctly ty~ed, retry the command after a file tag slot becomes available and the specified file is accepted and engueued by Rses. The link identified by "linkid" was inactive and has become active as a result of command processing. !he message describes the variable attributes in effect for this active link. task type 6701 LINK linkid ACTIVE -- LINE vaddr (HOI NOH) Ex~lanatio~: This message is issued in response to a QUERY SYS!E! command. One such message is produced for each active link in the RSCS facility at the time of command processing. The active link described by the message is identified by "linkid". vaddr HO NOH - the virtual device address of the line port in use by the active link. indicates that the active link is in hold status. indicates that the active link is not in hold status. ~~ Ac!iQB: This message is each active link in the system. Q~~g~ Actig~: issued for vaddr c the task name associated with the activated link's line driver. - the ID of the line driver in use by the activated link. - the virtual device address of the line port in use by the activated link. - the class or classes of files that can be processed by the actiVated link. ~Y§~! A£!i~: The activated link remains active, and the listed attributes remain in effect, until the link is deactivated or the attributes are explicitly modified. The link is activated whether or not a line connection to the remote location is complete. If no line connection exists, the line driver establishes a connection, with operator intervention if necessary. When a connection exists, file transmission begins automatically ,if a file gueue exists for the link. None. 701E NO SWITCHED LINE AVAILABLE NOT ACTIVATED 6711 LINK linkid INACTIVE I.!planati.sm: This message is issued in response to a QUERY SYSTEM command. One such message is produced for each inactive link in the RSCS facility at the time of command processing. The inactive link is identified by "linkid". LINK linkid jxplanatioB: An attempt was made to activate the link identified by "linkid" with no specified line port virtual device address. The link had no defined default line-port address, and no common switched line ports were available at the time of command processing. §l~ A£!iQB: This message is issued for each inactive link in the system. Syst~ Actio~: The command processing is terminated, the link remains inactive, and normal processing continues. Remote Spooling Communications Subsystem (RSCS) Messages 225 Dl'!T QE~~~~ Action: The command can be reissued wit~-a specified line port address, or it can be reissued when a common switched line ~ort becomes available. reissued with no li~e-port address at all, in which case an attempt is made to select and reserve a valid line port. 705E DRIVER type NCT FOUND ON DISK vaddr linkid NOT ACTIVATED 702E LINE vaddr IS IN USE EY LINK linkid1 LINK linkid2 NOT ACTIVATED LINK ~]A!ioB: llE!~s!i2E: An attempt was made to activate the link identified by "linkid2". The line-port virtual device address specified in the reguest to .ctivate the link, identified by "vaddr", was found to be in use by another active link, identified by "linkid1", at the time of command processing. ~~~!~ Acti2~: The command processing is terminated, the command has no effect, and normal processing continues. QE~~ A£!i2B: The command can be retried with a specified line port address that is not in use by another active link, or it can be retried with no line port address specified, in which case an attem~t will be made to reserve and utilize a valid line port. An attempt was made to activate the link identified by "linkid" with a driver ID identified by "type". The identified line driver could not be located on the disk used for driver task loading, identified by "vaddr". aIst~! !£!i£B: The command processing is terminated, the link remains inactive, and normal processing continues. Qpera!~ Acti£n: Verify that the driver ID used was correctly typed. If it was not, reissue the command, specifying a correct driver ID. If the command was correctly typed, notify a person responsible for system support. 706E FATAL ERROR LoADING FROM linkid NOT ACTIVATED vaddr LINK ]~lanation: 703E DEV cuu IS NOT A LINE POET NOT ACTIVATED lINK linkid was made to Ex~ls~tioB: An attempt activate the link identified by "linkid" with a line-port address identified by "cuu". A virtual device at address "cuu" exists, but it is not a usable line-port device. ~st~ !ctio~: The command processing is terminated, the link remains inactive, and normal processing continues. Q~~~ato~ Ac!ioB: The command can be reissued with a specified line-port address that is valid and available, or it can be reissued with no line-pert address at all, in which case an attempt is made to reserve and utilize a valid line port. 704E LINE vaddr CC=3 NOT linkid NOT ACTIVATED CPERATIONAI -- An attempt was made to activate the link identified by "linkid". In the process of loading the link's line driver from the disk identified by "vaddr", an uncorrectable I/O error was encountered. ~~!§! !£!i£]: Loading is abandoned, the error is logged, the command processing is terminated, and the link remains inactive. QR~~!2~ !£!iQ!: Reissue the command. If the error condition persists, notify operations or system support personnel. 707E DRIVER type FILE FORMAT linkid NOT ACTIVATED INVALID -- LINK £~s]Stion: An attempt was made to activate the link identified by "linkid", with a driver ID identified by "type". In the process of reading the driver file and loading the driver inte virtual storage, the loader detected an invalid data for~at in the driver file. LINK Explanation: An attempt was made to activate the link identified by "linkid" with a line-port address identified by "vaddr". Either no device was defined for the RSCS virtual machine at virtual address "vaddr", or the device at that address was completely nonoperational. Syst~ Actio]: Loading is abandoned, command processing is terminated, normal processing continues. the and Q~!~!Q! Action: Verify that the proper driver ID has been used. If an impro~er driver ID was used, reissue the command with a correct driver ID. If the proper driver ID was used, notify a person responsible for system support. ~stem ActiQB! The command processing is terminated, the link remains inactive, and normal processing continues. 708E VIRTUAL STORAGE CAPACITY EXCEEDED linkid NOT ACTIVATED -- LINK QE~ !£!!2B: The command can be reissued with a specified line-port address that is valid and operational, or it can be 226 IBM VM/SP System Messages and Codes !~1~~!~: activate the An attempt was made to link identified by "linkid". DB'! During the activation process, a virtual free storage requirement could not te met because there was not enough unclaimed virtual free storage in the system. System !£!i2n: The command processing is terminated, the link remains inactive, and normal processing continues. .Q:eerator Action: None. 709E tASK NAKE task ALREADY IN linkid NOT ACTIVATED USE LINK Operator Action: None. 7521 LINK linkid RESET STILL ACTIVE -- DRAIN STA'!US J~Elanation: A START command was issued specifying the link identified by "linkid". The link was active at the time of command processing, but it was in the process of terminating as the result of a prEvious DRAIN command. The link remains active, and the attributes remain as ~reviously set. Explanation: An attempt to activate the link "linkid", in response to a START command, failed because the task name "task" specified for use was in use by another task in the system. System Action: The S'!ART command is ignored, and normal processing continues. Qp~ !£!iQn: Reissue the StART command specifying a different task name, or reissue the START command aftEr the task with the conflicting name terminates. 8011 LINK linkid ERROR TRACE STARTED Explanation: As a result of command processing, the link identified by Ilinkid l has set its trace mode to trace line eIrors. ~l§!~! 710E "AX (nn) AC'!IVATED ACTIVE LINK linkid NO'! Explanation: An attempt to activate the link "linkid", in response to a START command, failed because the maximum allowable number "(nn)" of concurrent active links had already bEen reached. ~l§!~ Action: The S'!AR'! command is ignored, ina-iormal processing continues. Opera12! !gtion: Reissue the STAR'! command after one or more links bEcome inactive. 750E LINK linkid ALREADY TAKEN ACTIVE -- NO Qp~1: J~!~tion: As a result of command processing, the link identified by "linkid" has set its trace mode to trace all line activity. System Acti2B: A message describing line activity is displayed each time the numter of line transactions reaches the predefined threshold. 8031 LINK linkid TRACE ENDED j!Rl!~!!2!!: As a result of command pIocessing, the link identified by "linkid" has set its trace mode off. ~l§!~! Action: No further trace messages will be---dIsplayed, and normal link processing continues. None. Acti2!!: None. 751I LINK linkid ALREADY ACTIVE -- NEi CIASS(ES) SET AS REQUESTED Explanation: A START command was issued specifying the link identified by nlinkid n • The link was already active at the time of com.and processing, and the new class specification for the link has been accepted. ~§tem 8021 LINK linkid TRACE STARTED ACTION Explanation: A STAR'! command was issued specifying the link identified by "linkid". The link was already active at the time of command proce'ssing, and no modifiable attributes were changed from their ~revious settings. ~!im ~2n: Acti2!!: A message describing line activity is displayed each time the number of line errors reaches the predefined threshold. Action: The link automatically begins processing files tearing the newly specified class or classes, if any are enqueued on the link. Operator A&!i£n: None. 810E LINK linkid TRACE ALREADY ACTIVE A!B!!~!!: The link identified by "linkid" was in trace mode when it received a new command to enter trace mode, with the same options specified as had been active. ~lli2 ~: The link mode with the previous command has no effect, processing continues. remains in trace options set, the and normal link Remote Spooling Communications Subsystem (RSCS) Messages 227 DMT ~!g~ Actio~: The system now begins to transfer files. 811E LINK linkid TRACE NOT ACTIVE Ex~lgnatiQB: The link identified by "linkid" was not in trace mode when it received a command to set trace mode off. Operator Acti~: If only output files are to be handled, no action need be taken. If you want to transfer input to VI/370, follow the operator procedure for initiating card input. 2Y§!~m ActiQB: Trace mode remains off for the link, the command has no effect, and normal link processing continues. 906E INVALID SML BUFFER PARAMETER -- LINK linkid NOT ACTIVATED E1Blg~gtio~: 901E INVALID SML MODE SPECIFIED NOT ACTIVAT ED LINK linkid ExElsnati2~: The RSCS oFerator specified an invalid SML (Spool MUlTI-LEAVING) mode option in the PARM field of the RSCS START command. ~~ ActiQB: The specified activated. The RSCS operator specified an invalid SML buffer size in the tuffer option of the PARM field of the RSCS START command. 2l§!gm Actio~: activated. The specified QBg~g!2~ Acti~: Reissue the the correct S8L buffer size. link is Dot command with linkid is nat 907E SIGNON TYPE PARAMETER MISSING QEeratQ~ !£!io~: Reissue the the correct SMt mode. command with EXEl~tion: The TYPE parameter SIGNON card was omitted. ~§!~ Actio~: 902E NON-SIGNON CARD READ ON LINK linkid EXBlanatio~: The first record received from a remote station was not a SIGNON card. on the The signon is not allowed. Qpera!Q! Action: Correct the SIGNON card, reload the station, and sign on again. ~stg~ Actig~: station on allowed. The sign on of the remote the specified linkid is not QE~~ ActiQB: Correct the problem repeat the sign on procedure. and 903E PASSWORD SUPPLIED ON LINK linkid IS INVALID lxpla~2B: An invalid sign on attempt occurred. ~st~ ON LINK linkid INPUT lABlanation: A file was entered at a remote station without an ID card identifying the destination. ~1§! Action: The input file is flushed. Re~Q!g Q~g!2! !£!i~: Place an ID card on the front of the input deck and re~nter the input file. ActiQB: The sign on is not allowed. Remote QB~gtor Actig~: Correct the SIGNON card;- reload the station, and sign on again. 904E SIGNON PARAMETER=parameter INVALID lZElanation: An invalid entered on a SIGNON card. Syst~ Acti~: QB~~ parameter was The sign on is not allowed. ActiQ~: Correct tbe SIGNON card, and try again. 9051 SIGNON OF LINKID linkid COMPLETE lZElsnation: A valid SIGNON card has been received from the link serving linkid and the initialization of the SIGNON parameters is complete. 228 934E ID CARD MISSING FILE PURGED IBM VM/SP System Messages and Codes 935E LINK linkid IN spoolid PURGED PRINT RJE MODE FILE j~lanation: When D8TS8L is operating as an RJE (Remote Job Entry) station to a remote batch system, it is unable to transfer print files. Syst!.!!! Actio,!!: purged. Operator y§~ ~: The specified file is None. Action: The file must over a-different link. be trans.itted 936E NO REMOTE PUNCH AVAILABLE ON LINK linkid -PILE spoolid PURGED lxplanation: The remote station operating on this link has no remote punch available; therefore, punch files destined for tbis DMT link cannot be processed. .liIst~ purged. !£.ll.sm: Th e 937E DECOMPRESSION DEACTIVATED specified Us~ Action: The file must over a different link. file ERROR ON linkid LINK is ~!E~tioB: The remote transmitted data that decompressed correctly. be transmitted station cannot has be System Action: The link is deactivated. ~perato~ Acti2B: Follow operator procedure to restart link after following local corrective procedure. Remote Spooling Communications Subsystem (RSeS) Messages 229 230 IBM VM/SP System Messages and Codes Interactive Problem Control System (lPCS) Messages VM/SP adds no additional functions to the messages refer to VM/370 Release 6. Interactive Problem Control System (IPCS). Hence, these y§~~ 100S ERROR 'nnn' READING FILE 'filename filetype fm' Action: Check the macro description to see what type of failure nnn indicates. Correct the error and retry. IXElanatio~: An errcr occurred during the execution of an FSREAD macro against file 'filename filetype fm.' For a description of error 'nnn', see the FSEEAD macro in the VM/31Q ~MS ~2!~nd ~g ~£~2 B~!~~~]~~. 500S ERROR 'nnn' WRITING TO VIRTUAL PRINTER glE!g~~!ion: An error occurred during the execution of a PRINTL macro to the virtual printer. For a description of the return code, see PRINTL Macro in !M/37~ f!2 !;~ and ..H~ Ref~~nce. Actig]!: RC = 8 Processing stops and returns to CMS. .2.!st~ ]§~ Action: Check the macro description to see what type of failure nnn indicates. Correct the error and retry. 2Y§!~ !~: Use~ Ac!io~: Check the macro description to see what type of failure 'nnn' indicatEs. Correct the error and retry. 200S ERROR 'nnn' WRITING FILE 'filename filetype fm' ExEl~tion: An error occurred during the execution of an FSWRITE macro against file 'filename filetype fm.' For a description of error 'nnn', see the FSWRI!E macro in the !]L370 f~2 Comm~~g ~~g ~~£~~ Refe~~~. processing continues. 501S INVALID PARM 'badparm' SUMMARY UPDATE PROGRAM PASSED TO SYMP!OM ~~ElgBS!i2B: The program or EXEC that called SUMMARY passed an invalid reqUEst or a problem number not in the format PRBnnnnn, where nnnnn must be numeric. If a user program or EXEC was being executed, correct the parameter being passed to SUMMARY and retry. .2.!st~ ~2~: RC = 8 processing stops and returns to CMS. !£!iQg: Check the macro description to see what type of failure nnn indicates. Correct the error and retry. Q§~~ 2Y§!~! !£ ti 2B: RC = 'filename filetype 8 Execution of the command is terminated. !he system remains in the same state as before the command was issued. An error occurred during the execution of an FSSTATE macro against file 'filename filetype fm.· For a description of return code 'nnn', see the FS5TATE macro in the VM1370 f~2 ~~~~Bg ~Bg Mac~2 User !£!ion: If PROB, PRB, or VMFDUMP was being executed, collect the console log and call your IBM programming support representative. If a user program or EXEC vas being executed, correct the parameter being passed to SUMMARY and retry. 300S ERROR 'nnn' fm' ON FSS!ATE ExEl!B~: Refe~. RC = 8 Processing stops and returns to CMS. ~§te! Acti2~: Us~ !cti~: Check the macro description to see what type of failure 'nnn' indicates. Correct the error and retry. 502S PROBLEM 'PREnnnnn' SUMMARY NOT FOUND IN SYMPTOM !XElanatioB: Problem nnnnn was not found in the symptom summary file. Action: RC = 4 Execution of the command is terminated. The system remains in the same state as before the command vas issued. 2Y§!~! 4005 ERROR 'nnn' CLOSING 'filename filetype fm' EX2!anation: An error occurred during the execution of an FSCLOSE macro against file 'filename filetype fm~' For a description of return code 'nnn', see the FSCLOSE macro in the !~LJ1Q fMS ~2~~~~ sBg Ma£~ Re~~. .2.!st~ to CMS. Actig]!: Processing stops and returns ]§~~ Action: Retry the command the correct problem number. supplying 6011 OPERAND 'operand' NOT RECOGNIZED !~~~tiOB: The system received a search argument that was not recognized by the STAT command. IPCS Messages 231 DMM .§.Ist,!!! ~: RC = 4 Execution of the command is terminated. The system remains in the same state as before the command was issued. ]§~ Action: Retry the the correct operand(s). ccmmand specifying 70SE ERROR IN ITEM TABLE JZRlanation: While counting entries in the item table, the indicatcr for the end of the table was not found. Indicates that CP was unable to write the dump correctly or the dump has been ~amaged. ~l§!~ !£!i2n: processing continues. 7001 TYPE 'HELP' OR ENTER Ex~lanation: You have the opportunity to bypass a display of the DUEPSCAN subcommand summary. Syst~ Acti~: Processing continues. User Action: Some DUMPSCAN functions may Still be available. Beware of unlikely results. 706I 'entry name' NOT FOUND IN THE LOAD MAP ]~! Action: If you wish to display a summary of DUMPSCAN commands, type HELP. otherwise, press the ENTER key or its equivalent. JAP1An!!ion: The name displayed was entered to request a load map search and display function. However, the name was not found in the load map. 2Y§tem Action: processing continues. 701R ENTER DUMP NUMBER AND MOD! Explang!iQn: You are required to the dump number and mode. specify ]§!! J£!ion: Make sure that the entry point or module name is correct and retrl the subcommand supplying the correct module name. System Action: Processing continues. ]§§! Action: Enter the numeric part of the dump file name, followed by the disk mode. Leading zeros are nct required, so for PRB00056 on the A-disk, enter 56 A. If the mode is omitted, A is assumed unless you are changing dumps within a session, in which case the previcus mcde is used. 707! 'module' 'page' PAGE NOT VALID The page table entry for the virtual address page where 'module' was initially loaded was marked invalid and so could not be displayed. ~lanation: 2Y§!~ Action: processing continues. 7021 NON-HEX CHARACTER IN COUNT - RETRY ~ZB!~nati~: The count field in the input line contains a non-hexadecimal character. System Action: Processing continues. User Action: Make sure the count field contains--Qnly hexadecimal characters and reenter the subcommand. 7081 PAGE 'page' NOT FOUND IN DUMP EzP!!n!!ion: This virtual address was not represented by an entry in the item table. This means it was not dumped at the time the dump was taken. ~y§!§! 7031 NON-HEX CHARACTER IN ADDRESS - RETRY ~~2g: The address field non-hexadecimal character. ~st~ Acti~: 7091 NO VALID SCROLL ADDRESS User Action: Correct the input and retry. 7041 NON-HEX CHARACTER IN ADDRESS - R!TRY ~ystem glBl!~!i~: A SCROLL or SCROLL U request must follow some other request that generates a display that has an address associated with it. This has not happened yet in this DUMPSCAN session. Note that SCROLL will scroll from the last address that was displayed. contains a Acti£n: Processing continues. US§! Action: Correct the input and retry. 232 ]§!! A£!ion: Try another address. contains a Processing continues. FxBlgngtion: The address field non-hexadecimal character. !£!i2n: processing continues. IBM VM/SP System Messages and Codes Syst!! A£!i2n: processing continues. Action: Enter an address in you wish to examine by using hexloc'. ~! the area 'DISPlAY DfU! 1101 NON-NUMERIC COUNT CHARACTER - RETRY 7161 STRING 'string' {NOT POUNDINOT POUND EEFORE IND} EXElanation: The count field non-numeric character. ~§!S~ contains a EXE!g~tio!: The requested string was not found within the limits given or, if indicated, before the end of dumF was Acti 2n: Processing continues. ~eached. Q§~ !£!iQB: Correct the input and ~etry. ~l§!~~ ~: ~ 7111 LOOP IN VMBLOK CHAIN Action: Check that the string is as you intended, and retry the subcommand. EXE~tion: While searching th~ough the VMBLOK chains for entries no end was found to the chain. !Qte: This message will cccur if more than 256 users were logged on the system at the time of dump. Syst~ ~2B: 1111 INVALID PORM OF LOCATE COMMAND ]~~ion: The input on a LOCATE command was not in the proper format; that is Locate string [increment] Processing continues. Us~~ !Q!ig~: May indicate an overlay problem. Other DUMPSCAN functions may still be available. Continue. string fromhexloc 1121 DEVICE 'cuu' NOT FOUND EXj!lalliion: On a;real or virtual device request, the specified device was not found. tohexloc increment ~~ Processing continues. Agti2D: Processing continues. Q§~ Acti2n: Make sure the specified device is included in the system that Froduces the dump. Retry the sUbcommand. ~Y§!~~ fromhexloc tohexloc is up to 16 hexadecimal digits is an address up to six significant digits in length not highe~ than tohexloc is an address up to six digits that is higher than fromhexloc is an optional hexadecimal number from 1 to 1000 Actio!: Processing continues. User Action: Correct the input retry~ubcommand. format and 7131 USER 'userid' VMBLOK NCT FCUND Explanation: The specified 'userid' was not found so the VIa request could not be honored. ~§~ ~2n: Us~ ~: Processing continues. None. detected NO LOAD MAP SEE MAP ~IE!g!g!ion: The compressed load maF was not found at the end of the dump, possibly because NUC MAP was not available to VMPDUMP or was invalid. All DUMPSCAN functions except DMK? and DMKmmmee are still valid. a y§~£ System Acti2n: processing continues. Q§~ HAS al§!~~ ActioB= RC = 4 Processing continues. 1141 NON-HEX CHARACTER IN INFUT - RETRY ExmnatiQB: DMMHEX nonhexadecimal character. 1181 THIS DUMP SUBCOMMAND ActioB: Correct the input and retry. A£~: You may continue to use DUMPSCAN except for the DMK? subcommand and the DMKmmmee subcommand. If there is a valid CP nucleus load map available and if the dump is on the A-disk with write access, you may use the MAP subcommand to add the LOADMAP to the dump. 1151 NON-HEX CHARACTER IN STRING ~lli~!ion: of valid The input string must consist hexadecimal characte~s or 1191 ERROR 'nnn' filetype fm' IN FSSTATE FILE 'filename aste~isks. FSSTATE macro failed to find the dump file specified by your reFly to D!MDSC701R. £IElg~g!i£B: Syst~ ]§~ ActiQn: Processing continues. Acti2n: Correct the input and ~etry. Syst~ Action: Processing continues. IPCS Messages 233 DMM an~ ~ ~~~B£~. for a description of error nnn in the FSS!AT! macro. Correct the problem and retry. 1201 LOAD MAP ALREADY PRESENT 8005 DATA EXTRACTICH FAILURE jZE!~io~: Necessary portions of the dump file (PSA, symbol table, etc.) cannot he read. control is returned to DMMEDM and processing halts. ~]lanatiQE: The MAP subcommand was issued against a dump that already had a lCAD MAP appended. ~yst~~ ~ystem User Action: Retry the command when the cause of the READ failure is determined. !£11Qn: Processing continues. halts. problem 801I NUC MAP 'filename filetype fm' IS NOT VALID FOR THIS DUMP 1211 &NAME TABLE IS FULL ~lanation: You have run out of space in the SNAME table. The table can hold up to 32 tokens, either &NAMEs or suhcommand operands. syst~~ l£t!Q~: IPCS processing Control is returned to CMS. The report is not created. ~~l!~ion: The DMKCPEND address found in the dump and the one found in the load map (file NUC MAP) were not the same, indicating a back level lcad map. Processing in DMMMAP continues. lctiQn: Processing continues. ~l§t~~ User Action: You may replace a long &NAME entry--with a shorter one or you may terminate the session ana restart. This procedure clears out the table. Act!Q~: Messages DMMMAP802I and DMMMAP806R are subsequently issued requesting the name and location of the nucleus load map. y§~~ 7221 INVALID ENTRY INTO &HAM! !AELE 8021 FROCEEDING •••• !!E!~natiQn: The &NAME subcommand has found an invalid operand. See restrictions in the usage notes for DUMPSCAN. ~st~! Action: Respond to message DMMMAF806R •. ]AE1~nation: This message follows a prev10us error message indicating that even though an error was encountered, further processing will be attemfted. ActiQg: Processing continues. ~l§t~~ User Action: Reissue the t~correct operand. subcommand using !£!i~: Processing Message DMMMAP806R follows. Q§§~ l£!io~: 7231 THE DUMP IS NOT ON THE A-tISK Explanation: The MAP subcommand the dump to be on the A-disk. ~~~ requires User Action: Copy the dump to the A-disk of vIrtUal machine before issuing the MAP subcommand. your j~anatio~: VMFDUMP exceeds 64K in size; thus, it must be loaded in two sections. DMMINI is responsible for loading the second section (called VMFDUMP2) as soon as DMMEDM makes the first call to DMMINI. ~lst~! Action: If the LOADMOD is not successful, -VMFDUMP processing is halted immediately. Q§~ REQUESTED IN UNIPROCESSOR Explanatiog: The subcommand AREGS or MREGS was issued against a dump taken on a machine running in uniprocessor mode. syst~~ Respond to message DMMMAF806B. 803S EBROR 'nnn' ATTEMPTING TO LOADMOt VMFDUMP2 ActiQB: Processing continues. 7241 {APIMP} RIOBLOKS DUMP ActiQB: Processing continues. !£!i2B: Verify that you are exam1n1ng the correct dump. To see the registers, the PSW, etc., issue the REGS ccmmand. ~ Actio~: to !l!L37.Q For support instructions refer §,Yide. lR~'§ ~ 8041 ERROR IN DATA EXTRACTION l~plAnati2B: The text portion of the problem report may not be complete due to the absence of supporting information (for example, NUC HAP A1 does not match the system). This message is also issued if subroutines, such as DMftGRC, encounter an error reading from the dumpfile, or DftMCPA cannot recognize the abend code. ~l§!§! !£!!~: 234 continues. IBM VM/SP System Messages and Codes IPCS processing continues to t!! extract as much data as possible. This message occurs on the terminal as well as in the text portion of the problem report. Usg Action: None. 809I REQUESTED ADDRESS NOT IN DUMP ]!E!~nation: An address passed to the dump record read routine could not be found in the dump. Probably caused by a storage overlay or an invalid register address in the dump. 8051 xxxxxx ABEND CODE NOT tCCUKENTED ~l§!g! Explanation: This message is issued in module DMMCPA if the abend code in the dump does not compare with any abend code in the lookup table. !£!iQll: IPCS data extraction continues to gather dum~ information on a limited basis depending on the nature of the error. y~~ Agtion: None. System ActiQB: processing continues. User Action: Either the abend code in the dump ~overlaid or an unknown abend code has been generated. Call yeur IBM program support representative. 810I ERROR 'nnn' READING FILE 'filename filetype fm' !!E!g~!ion: 806R ENTER 'filename filetype fm' LOAD MAP OR NULL LINE OF NUCLEUS EXElanation: This message is issued after it is determined that file NUC MAP A is not found or invalid. Syst~ Action: Processing halts system waits-for a reply. and the User Action: Enter the filename, filetype, iDa-filemode of the nucleus load ma~ that corresponds to the level of the dump being processed. If the information is not available, a 'null' entry will cause processing to continue on a limited basis. If a null entry is made, the sorted, compressed load map will not be appended to the dump. 8071 UNABLE TO filemode' LOCATE 'filename filetype After you responded to message DMMMAP806R, DMMMAP was unable to locate the filename entered. An error occurred trying to read either NUC MAP or the file you specified in reply to message DMMMAP806R. ~l§!g! Acti2n: processing continues. User Action: an explanation and of error nnn see the FSREAD macro in the ~370 eMS ~~~~ and ~g£~Q Reference. Correct the error and reply to--the~llowing DMMMAP806R message with the fileid or null. 8501 UNABLE TO READ DUMP FROM READER !ZE!gng!ion: The VMFDUMP command was unacle to read the 3704/3705 dump or the system abend dump from the CP spool file through the CMS card reader. This could be because: • The reader is not at address OOC, • The reader at OOC is already in open status from a previous operation, or • The device in the virtual machine at OOC is not a CP spool card reader device. ]zE1~atiQB: ~ste~ ActiQn: processing DMMMAP806R is reissued. continues. Y§~f User Action: Respond to message DMMMAP806R with name and location of the nucleus load map. 8081 NUCLEUS MAP filemode' INVALID 'filename filetype ExE!!nation: Issued after you respond to message DMMMAP806R and the address of DMKCPEND in the dump does not correspond to the address of DMKCPEND in the load map. !ctiQB: Verify that the virtual machine configuration is correct for performing a VMFDUMP operation and that the card reader at OOC is a spool card reader in closed status. 8511 TEN DUMP FILES ALREADY EXIST Explanation: The command has not been executed because ten dum~ files with names DUMPOO through DMP09 already exist on the CMS disk being accessed. ~12!~ ~stem ActiQn: Processing Message DMMMAP806R is reissued. For detaile~escription Action: The command is terminated. continues. Usg Action: Respond to DMMMAP806R with name and location of the nucleus load map. User Action: purge one or more of the unwanted dump files or rename any of the existing dump file using the CMS BENAKE command. Reissue the command so that a dump file can be automatically created. IPCS Messages 235 DMM 8521 FATAL I/O ERROR WRITING DU~F ]zBlanation: An unrecoverable I/O error occurred during the writing of the 3704/3705 dump or the system abend dump on the CMS disk being accessed. The message is preceded by CMS error messages for the disk function. User Action: Reissue the command after taking-action to bypass the I/O errors on the CMS disk being accessed. 861E DUMP FILE 'filename' NOT FOUND ~lE!~~!i2B: The command was specified requesting a printout of a specific dump file, and that file could not be found on the CMS disks that were currently accessed. YBer Actio~: Verify that the correct dump file was specified and that the correct disks are accessed by CMS. Then reissue the command, requesting the specified dump file. 8531 NO DUMP FILES EXIST 863E INVALID PARAMETER - parameter ]z]la~tioB: The VMFDUMP command was specified, and the return from the CP interface indicates that no dumF files exist for this user. Q§~ Acti2B: Verify that the dump files produced by the CP system have the userid and the class required, and that this user's userid and class on the card reader match that of the dump, so that a dump file can be read. If no dump files exist, VMFDUMP does not have to be issued. If the dump file exists under a different userid, have the operator transfer that file to the required userid, so that it can be accessed. Also, verify that the input class of the spool card reader at OOC is class D, so that it can read the dump file. 860I FATAL I/O ERROR REAtING DUMF ]zplanation: During the reading of the dump from the CMS disk, an unrecoverable I/C error occurred. This message is preceded by a CMS message indicating the disk failure. User Action: Take corrective action to bypass- the-I/O error. Then reissue the command requesting to print the dump previously loaded onto the disk. 236 IBM VM/SP System Messages and Codes ]~]!~~atio~: The command was specified with a list of options, one of which is not recognized by the commapd. ~lB!~! !ctioB: The command is not executed. User Action: Reissue the only -valid options as command syntax. command; specify defined in the 8641 PAGE REFERENCED NOT AVAILABLE WHILE EDITING xxxxxxxx Explanation: During the format dump phase of the VMFDUMP command, a page was referenced in one of the CP control tlccks (identified by 'xxxxxxxx'), and that page is not available because it is beyond the range of the CP nucleus. ~lst~! !cti~D: VMFDUMP attempts to continue formatting at the next valid control block. User Action: No action can be taken on the part of the user to circumvent this problem since it usually indicates CP system software failures that caused the addressing of unreferenced pages. D"K Appendix A. Command-to-Message Cross-Reference This appendix contains an alFhabetical listing of CP, CMS, RSCS, and IPCS command, together with their associated messages. Under each command, the messages are listed in message-number seguence within module code. Note: RSCS and IPCS messages '6level. remain at the V"/370 Release CP Message Summary ACNT D"KAC0425A DMKAC0425E DMKCPV003E DMKCPV007E DMKCPV020E DMKCPV045E DMKCPV143E PUN cuu ACCOUNTING DATA; FATAL I/C ERROR I/O ERROR DURING ACCCUNTING INVALID OPTION - oFtion INVALID USERID - userid USERID MISSING OR INVALID userid NOT LOGGED CN type raddr IN USE BY SYSTEM ADS TOP DMKCFD004S DMKCFD026E DMKCFD160E DMKCFD164E DMKV"A181E INVALID HEXLOC - hexloc OPERAND MISSING CR INVALID HEXLOC hexloc EXCEEDS STORAGE HEXLOC hexloc NON-AtDRESSAELE STORAGE SHARED SYSTEM name REPLACED WITH NON-SHARED COpy ATTACH DMKNEA121E DMKSSS070E DMKSSS071E DMKSSS072E DMKSSS074E DMKSSS075E DMKSSS0781 DMKVDE003E DMKVDE006E DMKVDE020E DMKVDE021E DMKVDE022E DMKVDE023E DMKVDE034E DMKVDE040E DMKVDE045E DMKVDE046E DMKVDE120E DMKVDE121E DMKVDE122E DMKVDE123E DMKVDE124E DMKVDE125E DMKVDE126E DMKVDE127E DMKVDE128E DMKVDE131E DMKVDE133E DMKVDE134E DMKVDE142E DMKVDE143E DMKVDE153E DMKVDE199E DMKVDE9621 PRT resid NOT ATTACHED TO userid DEVICE NOT AVAILAELE - MSS DEVICES ALLOCATED DEVICE NOT AVAILAELE - MSS CANNOT EE ACCESSED DEVICE NOT AVAILAELE - 'raddr' NOT PROPER TYPE MISSING INTERRUPT - DEVICE 'raddr' DEVICE 'raddr' IS NOT AVAILAELE MSS MOUNT PROCEEDING FCR VCLUME 'volid' INVALID OPTION - oFtion INVALID DEVICE TYPE - addr USERID MISSING OR INVALID RADDR MISSING OR INVALID raddr VADDR KISSING OR INVALID vaddr VOLID MISSING CR INVALID CHANNEL MISSING OR INVALID DEV addr DOES NOT EXIST userid NOT LOGGED ON type raddr OFFLINE type raddr NOT ATTACHED; userid vaddr ALREADY DEFINED type raddr NOT ATTACHEt TO userid type raddr ALREADY ATTACHED to userid DASD raddr CF CiNED DASD raddr IN USE BY nnn USERS DASD raddr VOLID volid ALREADY ATTACHED TO SYSTEM DASD raddr ERROR READING VOLID DASD raddr VOLID volid DOES NOT MATCH DASD raddr ERROR READING ALLOCATION RECORD INSUFFICIENT FREE STORAGE AVAILABLE FOR ATTACH REQUEST DASD raddr NOT READI type vaddr NOT ATTACHED; CHAN x DEDICATED type raddr NOT DRAINED type raddr IN USE BI SYSTEM DEVICE {vaddrIRNG} EXCEEDED MAX NUMBER OF VIRTUAL DEVICES COMMAND REJECTED; DEVICE raddr PENDING OFFLINE CP OWNED DASD cuu VCLID volid INVALID ALLOCATION RECORD Appendix A. Command-to-Message Cross Reference 237 DMK ATT ACH CHANNEL DMKACR149E DEVICE PATH raddr ~ROC addr PRESENTED cc3 ON I/O REQUEST DMKVCH034E CHANNEL MISSING OR INVALID DMKVCH048E CHANNEL X DOES NCT EXIST DMKVCH129E CHANNEL X DEVICES IN USE DMKVCH130E CHANNEL X [PROC nn] NO~ ATTACHED TO userid DMKVCH132E CHANNEL X ALREADY DEFINED EY userid DMKVCH147E CHANNEL X {PROC nn} NOT ATTACHED; ALTERNATE PATH DEFINED DMKVCH188E SPECIFIED PROCESSOR UNAVAIIAELE DMKVDE020E userid MISSING OE INVALID DMKVDE039E PROCESSOR ADDRESS MISSING OR INVALID DMKVDE045E userid NOT LOGGED ON AUTOLOG DMKALG059E AUTOLOG FAILED FCE userid {IPL MISSINGIIPL FAILEDIACCOUNTING ERRORIINCORRECT PASSWORD} DMKALG115E AUTOLOG INVALID; EXCESSIVE INCORRECT PASSWORDS BACKSPAC DMKCS0003E DMKCS0006E DMKCS0021E DMKCS0040E DMKCS0046E DMKCS0140E DMKCS0141E DMKRSE240E DMKRSE241E DMKRSE2421 DMKRSE2521 DMKRSE2551 DMKCS0441E INVALID OPTION - option INVALID DEVICE TYPE'- addr RADDR MISSING eR INVALID DEV addr DOES NOT EXIS~ type raddr OFFLINE type raddr ATTACHED TO userid type raddr NOT ACTIVE PRT cuu, FCB-FORMS MISMATCH, FILEID nnn {HELDIPURGED} PRT cuu, INVALID LOAD MODULE mmmm SPECIFIED, FILE nnnn {HELDIPURGED} PRT cuu (3800) INTERVENTION REQD, STATUS CODE cc PRT cuu, FILE nnnn REQUEUE! AND HELD PRT cuu, PAGE EUFFER DESTROYED, BACK UP PAGE COUNT = nnnn NOT ACCEPTED. PREVICUS EACKSPACE STILL BEING PROCESSED BEGIN DMKCFC004S INVALID HEXLOC - hexloc CHANGE DMKCSU003E DMKCSU006E DMKCSU008E DMKCSU013E DMKCSU026E DMKCSU027E DMKCSU028E DMKCSU029E DMKCSU030E DMKCSU032E DMKCSU035E DMKCSU042E DMKCSU243E DMKCSU245E DMKCSU246E DMKCSU253E INVALID OPTION - option INVALID DEVICE TYPE - addr INVALID SPOCLID - sFoolid CONFLICTING OPERAND - operand OPERAND MISSING CR INVALID SPOOLID MISSING OR INVALID CLASS MISSING eR INVALID FNAME FTYPE MISSING OR INVALID COPIES MISSING OR INVALID DIST CODE MISSING OR INVALID DEVICE TYPE MISSING OR INVALID SPOOLID nnnn DOES NOT EXIST FLASH MISSING eR INVALID CHARS MISSING OR INVALID FCB MISSING OR INVALID MODIFY MISSING OR INVALID CLOSE DMKCSP003E DMKCSP006E DMKCSP013E DMKCSP022E DMKCSP029E DMKCSF032E DMKCSP040E INVALID OPTION - option INVALID DEVICE TYPE - addr CONFLICTING OPERAND - operand VADDR MISSING CR INVALID FNAME FTYPE MISSING OR INVALID DIST CODE MISSING OR INVALID DEV addr DOES NOT EXIST COUPLE DMKDIB006E DMKDIB011E DMKDIB020E DMKDIB022E DMKDIB040E DMKDIB045E DMKDIB047E DMKDIB058E INVALID DEVICE TYPE - addr INVALID DEVICE TYPE - userid vaddr USERID MISSING OR INVALID VADDR MISSING OR INVALID DEV addr DOES NOT EXIST userid NOT LOGGED ON userid vaddr DOES NOT EXIST CTCA vaddr BUSY ON userid 238 IBM VM/SP System Messages and Codes DMK CPTRAP D"KTRP002E D"KTRPOOSE D"KTRP013E DMKTRP020E DMKTRP026E DMKTRP04SE D"KTBP304E D"KTRP30SI DMKTRP306E D"KTRP309E DMKTRT3011 D"KTRT3081 INVALID OPERAND - o~erand INVALID HEXDATA - hexdata CONFLICTING OP~ION - option USERID "ISSING OB INVALID OPERAND MISSING OR INVALID userid NOT LOGGED eN CPTRAP IS STOPPING, NO INPUT ALLOWED CPTRAP SELECTIVITY BESET CPTRAP IS ALREADY ACTIVE OPERAND IGNORED SELECT TAEIE FULL CPTRAP (CP/VIRTUAL) ecce INTERFACE DATA IGNORED CPTRAP DATA LOST DCP DMKCDB003E DMKCDB004S DMKCDB009E DMKCDB010E DMKCDB026E DMKCDE033E DMKCDB160E INVALID OP~ION - option INVALID HEXLOC - hexloc INVALID RANGE - range INVALID REGIS~ER - register OPERAND MISSING CB INVALID HEXLOC MISSING OR INVALID HEXLOC hexloc EXCEEtS STORAGE DMKDDR100E DMKDDR701E DMKDDR702E DMKDDR703E DMKDDR104E DMKDDR10SE INPUT UNIT IS NOT A CPVCL INVALID OPERAND - xxxxxx CONTROL STA~EMEN~ SEQUENCE ERROR OPERAND MISSING DEV cuu NO~ OPERA~IONAL 10 ERROR cuu CSW csw SENSE sense INPUT bbcchh OUTPU~ bbcchh CCW ccw 10 ERROR cUU CSW csw SENSE sense INPUT bbcchh OUTPU~ (btcchhlnnnnnn) CCW ccw MACHINE CHECK RUN SEREF ANt SAVE OUTPUT FOB CE INVALID INPUT eR CUTPUT DEFINITION WRONG INPUT TAPE MOUNTED DEV cuu INTERVENTICN REQUIRED VOLID READ IS volid2 {NOT volid1} DO YOU WISH TO CCNTINUE? RESPOND YES NO OR REREAD: NUMBER OF EXTENTS EXCEEDS 20 OVERLAPPING OR INVALID EX~EN~S RECORD bbcchh NO~ FCUND CN TAPE LOCATION btcchh IS A FLAGGED TRACK NO VOL1 LABEL FOUND {FOB xxxxxx} DO YOU WISH TO CONTINUE? RESPOND YES OR NO OR REREAD: DATA DUMPED FROM volid1 TO EE RESTORED TO volid2. DO YOU WISH TO CONTINUE? RESPOND YES NO OR REREAD: OUTPUT UNIT IS FILE PRCTECTED INVALID FILE NAME OR FILE NO~ FOUND ERROR IN routine RECORD cchhr NO~ FOUND OUTPUT UNIT NOT PROPERLY FORMATTED FOR THE CP NUCLEUS NO VALID CP NUCLEUS ON THE INPUT UNIT INPUT TAPE CONTAINS A CP NUCLEUS DUMP ORIGINAL INPUT DEVICE WAS (IS) LARGER THAN OUTPUT DEVICE. DO YOU WISH TO CON~INUE? RESPOND YES OR NO: MOVING DATA INTO THE ALTERNATE TRACK CYLINDER(S) IS PROHIBITED FLAGGED TRK xxxxxxxxxx HAS NO PROPER ALTERNATE; SKIPPING THIS TRK FULL TRACK NO~ AVAILABLE PROGRAM CHECK PSW = psw SYSTEM AUTO DUMP REALLOCA~ED TO DASD raddr DDR DMKDDR105E D"KDDR707E DMKDDR708E D"KDDR709E DMKDDR710A DMKDDR111R DMKDDR712E DMKDDR113E DMKDDR114E DMKDDR115E DMKDDR116R DMKDDR717R DMKDDR118E DMKDDR719E D"KDDR720E DMKDDR121E DMKDDR122E DMKDDR723E DMKDDR724E DMKDDR725R DMKDDR126E DMKDDR127E DMKDDR7291 DMKDDR756E DMKDDR9251 DEFINE DMKDEF003E DMKDEF022E DMKDEF024E DMKDEF024E DMKDEF025E DMKDEF026E DMKDEF136E DMKDEF274E DMKDEF275E DMKDEF276E INVALID OPTION - oFtion VADDR MISSING CR INVALID CYLS MISSING OR INVALID (CYLSIBLKS) MISSING OR INVALID STORAGE MISSING OR INVALID OPERAND MISSING CB INVALlt DEVICE (vaddrlraddr) NOT {DEFINEDIVARIED}; CHANNEL XX DEDICATED DEV raddr HAS A MOUNTED VOLUME. MSS ID NOT AVAILABLE TC DEMOUNT IT raddr ALREADY SYSVIRT raddr NOT 3330V Appendix A. Command-to-!essage Cross Reference 239 DMK DMKDEF277E DMKDEF278E DMKDEF279E DMKDEF280E DMKDEF040E DMKDEF091E DMKDEF092E DMKDEF094E DMKDEF095E DMKDEF136E DMKDEF153E DETACH DMKNEA020E DMKVDD006E DMKVDD020E DMKVDD021E DMKVDD022E DMKVDD040E DMKVDD045E DMKVDD046E DMKVDD121E DMKVDD123E DMKVDD124E DMKVDD135E DMKVDD140E DMKVDD142E DMKVDD143E DMKVDD273E raddr ERROR DEMOUNTING VOLUME DEVICE NOT A EASD DASD NOT VUA raddr ALREADY VIR1UAL DEV addr DOES NOT EXIST DASD vaddr NOT DEFINED; TEMP SPACE NOT AVAILABLE DEV vaddr NOT DEFINED; type vaddr ALREADY DEFINED STORAGE EXCEEDS ALLOWED MAXIMUM DEV vaddr NeT DEFINE; INSUFFICIENT FREE STORAGE DEV vaddr NOT DEFINED; CHAN x DEDICATED DEVICE {vaddrIRNG} EXCEEDED ~AX NUMBER OF VIRTUAL DEVICES USERID MISSING OR INVALID INVALID DEVICE TYPE - addr USERID MISSING OR INVALID RADDR MISSING OR INVALID raddr VADDR MISSING OR INVALID vaddr DEV addr DOES NOT EXIST userid NOT LOGGED ON type raddr OFFLINE type raddr N01 A1TACHED ta userid DASD raddr CP CWNED DASD raddr IN USE BY nnn USERS type vaddr NOT DETACHEt; CHAN x DEtICATED type raddr ATTACHED TO userid type raddr NCT DRAINED type raddr IN USE EY SYSTEM DETACH REJ VIRTUAL MACHINE TBACING I/O DETACH CHANNEL DMKVCH034E CHANNEL MISSING OR INVALID DMKVCH048E CHANNEL x DOES N01 EXISl DMKVCH130E CHANNEL x [FRCC nn] NOl ATTACHED TC userid DMKVCH138E CHANNEL x NOT AT1ACHED; INSUFFICIENT STORAGE DMKVCH188E SPECIFIED PROCESSCR UNAVAIIAELE DMKVDE039E PROCESSOR ADDRESS MISSING OR INVALID DMKVDD020E USERID MISSING OR INVALID DMKVDD034E CHANNEL MISSING OR INVALID DIAL DMKDIA011E DMKDIA017E DMKDIA020E DMKDIA022E DMKDIA045E DMKDIA047E DMKDIA055E DMKDIA056E DMKDIA098E INVALID DEVICE TYPE - userid vaddr SCREEN SPACE - CLEAR SCREEN AND REDIAL USERID MISSING OR INVALID VADDR MISSING eR INVALID userid NOT LOGGED ON userid vaddr DeES NOT EXIST LINE(S) NOT AVAILABLE ON userid LINE vaddr BUSY ON userid DEV rid MODE SWITCH NOT ~OSSIBLE D~KDIA199E COMMAND REJECTED; DEVICE raddr PENDING OFFLINE DMKDIA206E CANNOT CONNECT TO HOST VIRTUAL MACHINE DHKDIA707A DIAL FUNCTION NOT AVAILABLE DIRECT DMKDIR751E DMKDIR752E DMKDIR753E DMKDIR754E DMKDIR155E DMKDIR156E DMKDIR757E DMKDIR758E DMKDIR160E DMKDIR761E DMKDIR762E DMKDIR763E DMKDIR764E 240 INSUFFICIEN~ INVALID OPERAND - xxxxxx STATEMENT SEQUENCE ERRCR FOLLOWING USER user OPERAND MISSING DEV cuu NOT OPERATIONAL 10 ERROR cuu CSW csw SENSE sense PROGRAM CHECK PSi = psw MACHINE CHECK RUN SEREP AND SAVE OUTPUT FOR CE DUPLICATE UNIT DEFINITION NOT ENOUGH SPACE ALLOCATED FOR DIRECTORY VOLID READ IS valid1 NOT volid2 DIRECTORY STATEMENT MISSING INVALID FILENAME OR FIli NCT FOUND ERROR IN routine IBM VM/SP System Messages and Codes DMK DISABLE DMKCPV003E DMKCPV006E DMKCPV021E DMKCPV026E DMKCPV040E DMKCPV046E DMKCPV140E DMKCPV199E DMKCPV923I DMKCPV9241 INVALID OPTION - option INVALID DEVICE TYPE - addr RADDR MISSING OR INVALID OPERAND MISSING CR INVALID DEV addr DOES NO~ EXIS~ type raddr OFFLINE type raddr ATTACHED TO userid COMMAND REJECTED; DEVICE raddr PENDING OFFLINE FAILING STORAGE FRAME A~ LCCATION ~add~ xxxx ADDITIONAL FAILING STCRAGE FRAMES EXIST DISCCNN DMKUS0003E INVALID OPTION - option DMKUS0191E SECONDARY USER IS NOT AVAIIAELE DISPLAY DMKCDM003E DMKCDM004S DMKCDM009E DMKCDM010E DMKCDM026E DMKCDM160E INVALID OPTION - option INVALID HEXLOC - hexloc INVALID RANGE - range INVALID REGISTER - ~egiste~ OPERAND MISSING OE INVALID HEXLOC hexloc EXCEEDS STORAGE DMCP DMKCDM003E DMKCDM004S DMKCDM009E DMKCDM033E DMKCDM160E INVALID OPTION - 0Ftion INVALID HEXIOC - hexloc INVALID RANGE - range HEXLOC MISSING OE INVALID HEXLOC hexloc EXCEEDS STORAGE DRAIN DMKCS0003E DMKCS0006E DMKCS0021E DMKCS0040E DMKCS0046E DMKCS0140E INVALID OPTION - option INVALID DEVICE TYPE - addr RADDR MISSING OR INVALID DEV addr DOES NOT EXIST type raddr CFFLINE type raddr ATTACHED TO use rid DUMP DMKCDM003E DMKCDM004S DMKCDM009E DMKCDM033E DMKCDM060E DMKCDM061E DMKCDM160E INVALID OPTION - option INVALID HEXLOe - hexloc INVALID RANGE - range HEXLOC MISSING OR INVALID DUMP FAILED; VIRTUAL PEINTER UNAVAILABLE DUMP FAILED; VIR~UAL PRINTER ERROR HEXLOC hexloc EXCEEIS STORAGE ECHO None. ENABLE DMKCPV003E DMKCPV006E DMKCPV021E DMKCPV026E DMKCPV040E DMKCPV046E DMKCPV140E DMKCPV199E DMKLD09231 DMKLD09241 INVALID OPTICN - option INVALID DEVICE TYPE - add~ RADDR MISSING CR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIS~ type raddr OFFLINE type raddr ATTACHED to userid COMMAND REJECTED; DEVICE raddr PENDING OFFLINE FAILING STOBAGE FRAME AT LCCATION raddr xxxx ADDITIONAL FAILING STORAGE FRAMES EXIST EXTERNAL DMKCPB005E INVALID HEXDATA - hExdata Appendix A. Command-to-Message Cross ReferEDce 241 DMK FLUSH DMKCS0003E DMKCS0006E DMKSC0013E DMKCS0021E DMKCS0040E DMKCS0046E DMKCS0140E DMKCS0141E INVALID OPTION - option INVALID DEVICE TI~E - addr CONFLICTING OPERAND - operand RADDR MISSING CR INVALID DEV addr DOES NOT EXIST type raddr OFFLINE type raddr ATTACHED TO userid type raddr NOT ACTIVE FORCE DMKUS0003E INVALID OPTION - option DMKUS0020E USERID MISSING OR INVALID DMKUS0045E userid NOT lOGGED CN FREE DMKCSP006E DMKCSP007E DMKCSP020E DMKCSF053E INVALID DEVICE TI~E - addr INVALID USERID - userid USERID MISSING OR INVALID userid NOT IN CF DIRECTORY HALT DMKCPS021E RADDR MISSING OR INVALID DMKCPS040E DEV addr DOES NOT EXIST DMKCPS144W type vaddr RESET EY userid HOLD DMKCPI9581 DMKCPI959W DMKCSP006E DMKCSP007E DMKCSP020E DMKCSF053E DMKTCS240E DMKTCS241E ATTACHED PROCESSOR NOT OPERATIONAL ATTACHED PROCESSCE NOT CNIINE INVALID DEVICE TIPE - addr INVALID USEEID - userid USERID MISSING OR INVALID userid NOT IN CP DIEECTCRY PRT cuu, PRT FCE-FORMS MISMATCH, FILEID nnnn {HELDIPURGED} PRT cuu, INVALID lCAD MODULE mmmm SPECIFIED, FILE nnnn {HEIDIFURGED} DMKTCT270E PRT xxx, TOO MANY WCGM'S NEEDED FOR 'CHARS', FILE nnnn HELD PURGED INDICATE DMKTHI002E DMKTHI003E DMKTHI026E DMKTHI045E INVALID OPERAND - operand INVALID OPTICN - option OPERAND MISSING OR INVALID userid NOT LOGGED ON IPL DMKCFG002E DMKCFG003E DMKCFG013E DMKCFG022E DMKCFG026E DMKCFG040E DMKCFG044E DMKCFG083E DMKCFG170E DMKCFG171E DMKCFG172E DMKCFG173E DMKCFG174E DMKCFG177E DMKCFG203E DMKCLK437E DMKCLK970W DMKCPI185E DMKCPI9131 DMKCPI9141 DMKCPI9231 DMKCPI9241 DMKCPI9581 DMKCPI959W DMKCPI9631 DMKCPI9641 DMKCPJ9661 DMKCPI970I 242 INVALID OPERAND - operand INVALID OPTION - oFtion CONFLICTING OPTION - option VADDR MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIST SYSTEM name DOES NCT EXIST VMSAVE AREA DOES NOT CONTAIN A VALID SAVED SYSTEM SYSTEM name EXCEEDS STCRAGE SYSTEM name VOLID valid NOT MOUNTED SYSTEM name DASD vaddr INCCMFATIELE SYSRES SYSTEM name REQUIRES DASD vaddr PAGING I/O ERROR; IFL FAILED PARM EXCEEDS 64 CHARACTERS V=R AREA REQUIRES IPL EY DEVICE ADDRESS SYSTEM PAGING SPACE NOT AVAILAELE, IPI TERMINATED TOD CLOCK SYNC CHECK RECEIVED CP ASSIST LEVEL xx DOES NOT MATCH CP LEVEL yy CP OWNED VOLID xxxxxx INVALID FOR 3330V TRACE TABLE IS SMALLER THAN REQUESTED FAILING STORAGE FRAME AT LCCATION raddr xxxx ADDITIONAL FAILING STORAGE FRAMES EXIST ATTACHED PROCESSCR NOT OPEEATIONAL ATTACHED PROCESSOR NOT ONLINE SECOND PROCESSOR NCT ONLINE PROC xx INITIALIZED; PROC yy INITIALIZED INITIALIZATION COMPLETE SYSTEM IS {UP lAP IMP} GENERATED IBM VM/SP System Messages and Codes DMKCPI9711 DMKCPI9621 DMKCPI950A DKKVKI022E DMKV!I230E D!KV!I231E DMKVMI232E D!KV!I233E DMKVMI234E SYSTEM IS {OPIAPIKP} GENERATED CP OWNED DASD cuu VCLID volid INVALlt ALLOCATION RECORD OPERATOR NOT LOGGED ON; EXPLICIT LOGON REQOIRED VADDR KISSING CR INVALID IPL SIO ERROR IPL TIO ERBOR IPL UNIT ERROR; CSi XXXXXXX! xxxxxxxx SIS IXXXXXXXXXXX IPL OVERLAY ERROR IPL SENSE ERROR JOURNAL DMKJRL1451 USERID: userid AT term-raddr WITH INVALID PASSWORD NO. xxx {psvd} BAS VIOLATED THE LI~IT CF 111 [,A=auserid] LINK DMKLNK020E DMKLNK022E D!KLNK052E DMKLNK053E D!KLNK101W D!KLNK102W DMKLNK103W D!KLNK104E D!KLNK105E D!KLNK106E DMKLNK107E D!KLNK108E DMKLHK109E DMKLBKll0E D!KLHK111E D!KLHKl12E D!KLNKl13E D!KLBK114E D!KLNK115E D!KLNK116E DMKLNKl17E D!KLNK118E DMKLNK119E D!KLNK137E DMKLNK139E DMKLNK153E DMKLNK199E DMKSSS070E DMKSSS071E DMKSSS073E DMKSS5078I LOADBOF DMKCSB003E 'DMKCSB006E D!KCSB013E DMKCSB021E DMKC5B026E DMKCSB031E D~KCSB036E DMKCSB046E D!KCSB040E D!KCSB043E D!KCSB140E D!KCSB142E D!KCSB148E LOADVFCB D!KCSB006E D!RCSB022E DMKCSB026E D!KCSB031E DMSCSB036E D!KCSB040E D!KCSB043E USERID MISSING CB INVALID VADDR MISSING OR INVALID ERROR IN CP DIBECTOEY userid NOT IN CP DIRECTORY DASD vaddr FORCED B/C; RIC EY nnn OSERS DASD vaddr FORCED RIO; R/i BY nnn OSERS DASD vaddr FORCED RIO; R/i BY nnn OSERS; RIC BY nnn USERS userid vaddr NCT lINKED; R/O EY nnn OSERS userid vaddr NOT LINKED; B/i BY nnn OSERS userid vaddr N.CT LINKED; Rli EY nnn OSERS; RIO BY nnn USERS userid vaddr NCT lINKED; NCT IN CP DIRECTORY userid vaddr NOT LINKED; VCLID volid NOT MCUNTED userid vaddr NOT lINKEt; INVALID LIBK DEVICE userid vaddr NCT lINKED; type vaddr ALREADY DEFINED userid vaddr NOT LINED; NO READ PASSiORD userid vaddr HOT LINKED; NO WRITE PASSWORD userid vaddr HOT LINKED; NO MULT PASSWORD userid vaddr NOT LINKED; PASSiORD INCORRECT LINK INVALID; EXCESSIVE INCORRECT PASSWORDS USERID xxx NOT LINKED; CP DIRECTORY IN OSE USERID USERID NOT LINKED; VOIID volid CONFLICT userid raddr NCT lINKEt; CCM!AND FORMAT NOT VALID USERID vaddr NOT LINKED; INSOFFICIENT FREE STORAGE DASD vaddr NOT LINKID; CHAN x DEDICATED DASD addr NOT LINKED; 3330V NOT ACCEPTED AS SYSTEM VOLUME DEVICE {vaddrIBNG} IXCIEDEt !AX NOMBER OF VIRTOAL DEVICES COMMAND REJICTED; DIVICE raddr PENDING OFFLINE DEVICE NOT AVAILAEL! - MSS DEVICES ALLOCATED DEVICE NOT AVAILAELE - MSS CANNOT EE ACCESSED DEVICE NOT AVAIIAEII - MSS ERROR M55 MOONT PROCEEDING FCR VCLOME 'volid' INVALID OPTION - cption INVALID DEVICE TYPE - addr CONFLICTING OPERAND - operand RADDR MISSING OR INVALlt OPERAND MISSING OR INVALID BUFFER MISSING OR INVALID INDEX MISSING OR INVALID type raddr OFFLINE DEV addr DOES NOT EXIS! BUFFER name DCES NC~ EXIST type raddr ATTACHED TO userid type raddr NeT DDAIN!D type raddr EOffER LOAD name fAILED INVALID DEVICE TYPE - addr VADDR MISSING OR INVALID OPERAND MISSING OR INVALID BUFFER RISSING OD INVALID INDEX MISSING OR INVALID DEV addr DOES NOT EXIST BUFFER name DOES NOT EXIST Appendix A. Command-to-!essage Cross Reference 243 DMK LOCATE DMKCFD021E DMKCFD022E DMKCFD026E DMKCFD040E RADDR MISSING OR INVALID VADDR MISSING eR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIST LOCK DMKCPV004S DMKCPV009E DMKCPV020E DMKCPV033E DMKCPV045E DMKCPV160E DMKCPV165I INVALID HEXLOC - hexloc INVALID RANGE - range USERID MISSING OR INVALID HEXLOC MISSING OR INVALID userid NOT LnGGED ON HEXLOC hexloc EXCEEtS STORAGE PAGE hexloc NOT LOCKED; SHARED PAGE LOGON DMKLOG003E DMKLOG020E DMKLOG050E DMKLOG052E DMKLOG053E DMKLOG067E DMKLOG054E DMKLOG080E DMKLOG081W DMKLOG082E DMKLOG090E DMKLOG091E DMKLOG092E DMKLOG093E DMKLOG095E DMKLOG131E DMKLOG188E DMKLOG189I DMKLOG250E DMKLOG251E DMKLOH196E DMKLOH206E DMKSSS070E DMKSSS071E DMKSSS072E DMKSSS073E DMKSSS0781 INVALID OPTION - oFtion USERID MISSING OR INVALID PASSWORD INCORRECT ERROR IN CF DIRECTORY userid NOT IN CP DIRECTORY COMMAND FOR~AT NeT VALID ALREADY LOGGED ON {LINEIGRAFILUNAME} raddr NO PREALLOCATED VMS AVE AREA VMSAVE AREA ALREADY IN USE, MUST USE SET COMMAND MORE THAN ONE VMS AVE AREA ALLOCATEt, MUST SPECIFY AREA NAME DEV vaddr NOT DEFINED; DEV {~addrlvolser} NOT AVAILAELE DASD vaddr NOT DEFINED; TE~P SFACE NOT AVAILABLE DEV vad~ NOT DEFINED; type vaddr ALREADY DEFINED DEV vaddr NOT DEFINED; ERRCR IN CP DIRECTORY DEV vaddr NOT DEFINED; INSUFFICIENT FREE STORAGE INSUFFICIENT FREE STORAGE AVAILABLE FOR LOGON REQUEST SPECIFIED PROCESSCR UNAVAIIAELE AFFINITY NOT SET; SYSTEM IN UNIPROCESSOR MODE 370E IS NOT AVAILAELE {ON PROC xx} 370E IS NOT ACTIVE SECONDARY USER IS NOT IN CF DIRECTORY CANNOT CONNECT TO HOST VIRTUAL MACHINE DEVICE NOT AVAILABLE - MSS DEVICES ALLOCATED DEVICE NOT AVAILAEIE - MSS CANNOT EE ACCESSED DEVICE NOT AVAILAELE - 'raddr' NOT PROPER TYPE DEVICE NOT AVAILABLE - MSS ERROR MSS MOUNT PROCEEDING FOR VOLUME 'volid' LOGOFF DMKUS0003E INVALID OPTION - cFtion MONITOR DMKCPI229I DMKMCC002E DMKMCC003E DMKMCC006E DMKMCC021E DMKMCC026E DMKMCC040E DMKMCC046E DMKMCC140E DMKMCC143E DMKMCC199E DMKMCC211E DMKMCD212E DMKMCC213E DMKMCD214E DMKMCC215E DMKMCC216E DMKMCC217E DMKMCD218E DMKMCD002E DMKMCD021E DMKMCD026E DMKMCD040E DMKMON2191 DMKMON2201 244 USER OF MONITOR DOES NOT EXIST INVALID OPERANt - operand INVALID OPTION - oFtion INVALID DEVICE TYPE - addr RADDR MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIST type raddr OFFLINE type raddr ATTACHED TO use~id type raddr IN USE EY SYSTEM COMMAND REJECTED; DEVICE raddr PENDING OFFLINE MONITOR TAPE IS AIEEADY ACTIVE MONITOR TAPE IS NOT ACTIVE MONITOR tPTRACE IS ALREADY ACTIVE MONITOR CPTRACE IS NOT ACTIVE MONITOR ACTIVE; DASTAP CANNOT BE ENABLED DYNAMICALLY SYSPROF CLASS IS DEPENDENT ON SCHEDULE AND DASTAP MONITOR TAPE NOT STARTED, NO CLASS ENABLED MONITOR NOT STOPPED, OUTSTANDING I/O INVALID OPERAND - operand RADDR MISSING OR INVALID OPERAND MISSING CR INVALID DEV addr DOES NOT EXIST END OF MONITOR TAPE, MONITOE STOPPED BY SYSTEM ERROR ON MONITOR TAPE, MONITOR STOPPED BY SYSTEM IBM VM/SP System Messages and Codes D~K DMKMCC221E DMKMCD222E DMKMCD223E DMKMCD224E DMKMNI225E DMKMCD226E DMKMCD227E DMKMCD228E DMKMIA229E MSG MONITOR TO SPOOL IS ALREADY ACTIVE TIME PARAME~EE SPECIFIES INVALID TIME START TIME MUST PRECEDE STOP TIME LIMIT MUST BE EETWEEN 10 and 50000 INVALID MONITOR USERID SPECIFIED, ~ON NOT ENABLED FOR VALUE SPANS MIDNIGHT - CCMMANt INVALID FOR OPTION INVALID WITH AUTODISK CFF FOR OPTION INVALID WITH MONI~OR ON MONITOR OUT OF DASI PAGES, IS SHUTTING OFF DMKMSG003E INVALID OPTICN - oFtion DMKMSG020E USERID MISSING OR INVALID DMKMSG045E userid NCT lOGGED CN D~KMSG057W userid NOT RECEIVING; {DISCONNECTEDIMSG OFFINOT DISCI NO CONSOLEISMSG OFFINCT AUTHORIZEDIWNG OFFIVMCF/IUCV ERROR nnn} NCPDUMP DMKRND8501 DMKRND8521 DMKRND8531 DMKRND8601 DMKRND861E DMKRND863E NETWORK DMKNES002E DMKNES004S DMKNES006E DMKNES009E DMKNES021E DMKNES026E DMKNES040E DMKNES046E DMKNES049E DMKNES098E DMKNES140E DMKNES160E DMKNES199E DMKNES706E DMKNET002E DMKNET003E DMKNE~004S DMKNET006E DMKNET009E DMKNET021E DMKNET026E DMKNET033E DMKNET040E DMKNET046E DMKNET049E DMKNET098E DMKNET140E DMKNET157E DMKNET160E DMKNET199E DMKNLD002E DMKNLD006E DMKNLD021E DMKNLD026E DMKNLD040E DMKNLD044E DMKNLD046E DMKNLD140E DMKNLD143E DMKNLD170E DMKNLD171E DMKNLD199E DMKNLD460E DMKNLD461R DMKNLD470E DMKNLD471E DMKNLE003E UNABLE TO READ DUMP FROM READER FATAL I/O EERCR WRITING DUMP NO DUMP FILES EXIST FATAL I/C ERRCR REArING DUMP DUMP FILE 'filename' NOT FCUND INVALID PARAMETER - parameter INVALID OPERAND - operand INVALID HEXLOC - hexloc INVALID DEVICE TYPE - raddr INVALID RANGE - range RADDR MISSING eR INVALIt OPERAND MISSING OR INVALID DEV raddr DOES NCT EXIST {DEV ridltype raddr} OFFLINE type raddr IN USE DEV rid MODE SWI~CH NOT POSSIBLE CTLR raddr AT~ACHEI TO userid HEXLOC hexloc EXCEEtS STORAGE COMMAND REJECTED; DEVICE raddr PENDING LINE addr NOT ENABLED INVALID OPERAND - operand INVALID OPTION - oFtion INVALID HEXIOC - hexloc INVALID DEVICE TYPE - raddr INVALID BANGE - range RADDR MISSING OR INVALID OPERAND MISSING OR INVAIII HEXLOC MISSING OR INVALID DEV raddr DOES NCT EXIST {DEV ridltype raddr} OFFLINE type raddr IN USE DEV rid MODE SWITCH NOT POSSIBLE type raddr ATTACHED TO userid CLUSTER= PARM MISSING FROM RDEVICE MACRO - DEV raddr HEXLOC hexloc EXCEErs STORAGE COMMAND REJECTED; DEVICE raddr PENDING OFFLINE INVALID OPERAND - oFerand INVALID DEVICE TYPE - raddr RADDR MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIST SYSTEM name DOES NOT EXIST CTLR raddr OFFLINE CTLR raddr ATTACHED TO userid CTLR 'raddr' IN USE BY SYSTE~ SYSTEM name EXCEEDS STORAGE SYSTEM name VCIID volid NOT MOUNTED COMMAND REJECTED; DEVICE raddr PENDING OFFLINE CTLB raddr LOAD FAILED: PROGRAM CHECK CTLR raddr IPL NOT REQUIREI; ENTER 'YES' TO CONTINUE CTLR raddr LOAD FAILED: PAGING I/O ERROR CTLR raddr LOAD FAILED: UNRECOVERAELE I/O ERROR INVALID OPTION - cFtion Appendix A. Command-to-Message Cross Reference 245 DKK DftKNLE006E DKKNLE021E DKKNLE040E DMKNLE046E DKKNLE140E DKKNLE143E DMKNLE199E DKKNLE460E DKKNLE461R DKKNLE4641 DMKNLE469E DKKNLE470E DKKNLE471E INVALID DEVICE !YPE - raddr RADDR KISSING OR INVALID DEV addr DOES NO! EXIS7 CTLR raddr OpPIIN1 CTLR raddr A~TACHED TO userid CTLR 'raddr' IN USE BY SYS!EK COMMAND REJECTED; DIVICE raddr PENDING OFFLINE CTRL raddr DUMP PAllED: PHCGEAK CHECK CTRL raddr IPL NOT REQUIRED; ENTER 'YES' TO CONTINUE CTRL raddr CC = 3; IEPRESS 370X "LOAD" BUTTON CTRL raddr DUMP FAILED; TE"P SPACE NOT AVAILABLE CTRL raddr DUMP PAllED: PAGING I/O EBBOR CTRL raddr DUMP FAILED: UNRECOVERABLE I/O ERROR NOTREADY DKKCPB006E INVALID DEVICE TYPE - addr DKKCPB022E VADDR KISSING CR INVALID DKKCPB040E DEV addr DOES NOT EXIST ORDER DftKCSU003E DKKCSU006E DKKCSU008E DKKCSU026E DKKCSU027E DKKCSU028E DMKCSU035E DKKCSU042E PURGE DKKCSU003E DMKCSU006E DKKCSU008E DKKCSU026E DMKCSU028E DMKCSU035E DMKCSU042E DMKTCS240E DMKTCS241E QUERY DKKCpC026E DKKCQG020E DKKCQG022E DKKCQG027E DMKCQG040E DKKCQG042E DMKCQG045E DMKCQP003E DMKCQP006E DMKCQP020E DMKCQP021E DKKCQP022E DMKCQP040E DMKCQP045E DKKCQP466I DKKCQR003E DMKCQR020E DMKCQR026E DMKCQR028E DKKCQR045E DKKCQY020E DMKCQY026E DMKCQY045E 246 INVALID OPTION - option INVALID DEVICE TIPE - addr INVALID SPOOLID -s~oolid OPERAND KISSING CR INVALID SPOOLID MISSING OR INVALID CLASS KISSING CR INVALID DEVICE TYPE MISSING OR INVALID SPOOLID nnnn DCES NCT EXIST INVALID OPTION - o~tion INVALID DEVICE TYPE - addr INVALID SPOCLID -spoolid OPERAND MISSING OR INVALID CLASS KISSING OR INVALID DEVICE TYPE MISSING OR INVALID SPOOLID nnnn DCES NeT EXIST PRT cuu, FCB-pORMS MISMATCH, pILEID nnnn {HELDIPURGED} PRT cuu, INVALID LOAD MODULE mmmm SPECIFIED, FILE nnnn {HELDIPURGED} OPERAND KISSING OR INVALID USERID KISSING OR INVALID VADDR MISSING OR INVALID SPOOLID MISSING CR INVALID DEV addr DOES NOT EXIST SPOOLID nnnn DOES NOT EXIST userid NOT LOGGED ON INVALID OPTION - o~tion INVALID DEVICE TYPE - addr USERID MISSING OR INVALID RADDR MISSING OR INVALID VADDR KISSING OR INVALID DEV addr DOES NOT EXIST userid NOT LOGGED ON CTLR cuu IN EUFpIR SLOWDOWN MODE INVALID OPTION - option USERID MISSING OR INVALID OPERAND MISSING OR INVALID CLASS MISSING OR INVALID userid NOT LOGGED eN USERID MISSING OR INVALID OPERAND MISSING OR INVALID userid NOT LOGGED ON IBft VM/SP System Messages and Codes DMK QVM DMKQVM020E DMKQVM800E DMKQVM801E DMKQVM802E DMKQVM803E DMKQVM806E DMKQVM807E DMKQVM809E USERID MISSING OR COMMAND REJECTED, FREE STORAGE PAGE COMMAND REJECTED, COMMAND REJECTED, COMMAND REJECTED, COMMAND REJECTED, COMMAND REJECTED, INVALID OTHER VIRTUAL MACHINES LOGGED ON IS NCT AVAILABLE DEVICES NOT DEDICATED SPOOL DEVICES NCT DRAINED VIRTUAL ADDRESS NOT EQUAL TO REAL ADDRESS V!/SP ATTACHED PROCESSOR MODE TRACE/ADSTOP/CCW TRANS IN EFFECT READY DMKCPB022E VADDR MISSING OR INVALID DMKCPB040E DEV addr DOES NOT EXIST DMKCPV006E INVALID DEVICE TYPE - addr REPEAT DMKCS0003E DMKCS0006E DMKCS0013E DMKCS0021E DMKCS0030E DMKCS0040E DMKCS0046E DMKCS0140E DMKCS0141E INVALID OPTION - oFtion INVALID DEVICE TYPE - addr CONFLICTING OPERAND - operand RADDR MISSING OR INVALlt COPIES MISSING OR INVALID DEV addr DOES NOT EXIST type raddr OFFLINE type raddr ATTACHED TO userid type raddr NOI ACTIVE RESET DMKCPB022E VADDR MISSING OR INVALID DMKCPB040E DEV addr DOES NOT EXIST REWIND DMKCPB006E INVALID DEVICE TYPE - addr DMKCPB022E VADDR MISSING OR INVALID DMKCPB040E DEV addr DOES NeT EXIST SAVESYS DMKCFH026E DMKCFH044E DMKCFH170E DMKCFH171E DMKCFH172E DMKCFH173E DMKCFH179E DMKCFH300E DMKCFH435E DMKCFH436E OPERAND MISSING CR INVALID SYSTEM name DOES NOT EXIST SYSTEM name EXCEEDS STCRAGE SYSTEM name VOLID volid NOT MOUNTED SYSTEM name DASD vaddr INCCMPATIBLE SYSRES SYSTEM name REQUIRES DASD vaddr SYSTEM name VOLID volid NOT CP OWNED SAVE REQUEST BEYOND VIRTUAL MACHINE SIZE PAGING ERROR WRITING SAVED SYSTEM INTERRUPT PENDING. TO PROCEED, TYPE YES. TO END, TYPE NC. SCREEN DMKCFW002E INVALID OPERAND - oFerand DMKCFW026E OPERAND MISSING CR INVALID SEND DMKSND020E USERID MISSING OR INVALID DMKSND045E userid NOT LOGGED ON DMKSND068E SEND COMMAND FAILED _ RECEIVER {IS NOT DISCONNECTEDI HAS NO AUTHORIZED SENDERIHAS NO VIRTUAL CONSOLEIHAS CONSOLE INPUT WAITI IS EXECUTING A CONSOLE FUNCTION} SET DMKCF0003E DMKCF0006E DMKCF0013E DMKCF0020E DMKCF0021E DMKCF0026E DMKCF0040E DMKCF0041E DMKCF0045E DMKCF0046E DMKCF0140E INVALID OPTION - oFtion INVALID DEVICE TYPE - addr CONFLICTING OPTION - oFtion USERID MISSING OR INVALID RADDR MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIST LOGMSG nn DOES NeT EXIST userid NOT LOGGED ON type raddr OFFLINE type raddr ATTACHED TO userid Appendix A. Command-to-Message Cross Reference 241 DMK DMKCF0143E DMKCF0175E DMKCF0184E DMKCF0186E DMKCF0188E DMKCF0199E DMKCF0250E DMKCF0255W DMKCF09251 DMKCF09531 DMKCFS003E DMKCFS006E DMKCFS026E DMKCFS045E DMKCFS046E DMKCFS052E DMKCFS053E DMKCFS140E DMKCFS183E DMKCFS184E DMKCFS187E DMKCFS188E DMKCFS189E DMKCFS1901 DMKCFS250E DMKCFS251E DMKCFV062E DMKCFV063E DMKCFV080E DMKCFV082E DMKMCH003E DMKMCH026E DMKMSG003E DMKVAT064E type raddr IN USE EY SISTEM {FAVOREDIRESERVE} ALREADI IN USE BI userid VM ASSIST NOT AVAILABLE {CN PROCESSOR proe addr} CP ASSIST NOT AVAILABLE SPECIFIED PROCESSOR UNAVAILABLE COMMAND REJECTED; DEVICE raddr PENDING OFFLINE 370E IS NOT AVAILABLE {ON PRCC xx} 370E FEATURE NOW DISABLED SISTEM AUTO DUMP REALLCCATED TO DASD raddr UNABLE TO ALLOCATE SISTEM AUTO DUMP INVALID OPTION - cption INVALID DEVICE TYPE - addr OPERAND HISSING CR INVALID userid NOT LOGGED ON DEV type raddr OFFLINE ERROR IN CP DIREC~ORY userid NOT IN CP DIBECTOBY type raddr ATTACHED TO userid VM ASSIST NOT ACTIVE VM ASSIST NOT AVAILABLE TIMER ASSIST NCT AVAILAEIE SPECIFIED PROCESSOR UNAVAILABLE AFFINITI NOT SET; SISTEM IN UNIPROCESSOR HODE NO AFFINITY SET IN DIRECTORY 370E IS NOT AVAILABLE {CN PRCC xx} 370E IS NOT ACTIVE ECMODE NOT SET ON SHADOW TABLE BYPASS; NOT SET NO PREALLOCATED V~SAVE AREA MORE THAN ONE VMSAVE AREA ALLOCATED; MUST SPECIFY AREA NAME INVALID OPTION - cption OPERAND MISSING OR INVALID INVALID OPTION - option SHADOW TABLE BYPASS; RESET SHUTDOWN None. SLEEP DMKCFC002E INVALID OPERAND - operand SMSG DMKHSG002E USERID MISSING OE INVALID DMKMSG045E userid NOT LOGGED ON DHKMSG057W userid NOT RECEIVING; {DISCONNECTEDISMSG OFFINOT AUTHORIZEDIWNG OFF} SPACE DHKCS0006E DMKCS0021E DMKCS0040E DMKCS0046E DHKCS0140E DMKCS0141E DHKSPS026E DMKSPS028E DHKSPS026E DMKSPS028E DHKSPS426E DHKSPS428E DHKSPT002E DHKSPT003E DHKSPT006E DMKSPT008E DMKSPT021E DMKSPT040E DMKSPT046E DMKSPT140E DMKSPT143E DHKSPT199E 248 INVALID DEVICE TYPE - addr RADDR MISSING CR INVALID DEV addr DOES NOT EXISi type raddr OFFLINE type raddr ATTACHED TO userid type raddr NOT ACTIVE OPERAND MISSING OR INVALID CLASS MISSING OR INVALID OPERAND MISSING OR INVALID CLASS MISSING CR INVALID (RDRITAPE} raddr SPOOL SPACE FULL; FILE PURGED {PRTIPUNIRDEITAPE} raddr SPoeL ERROR; FILE {HELDIPURGED} INVALID OPERAND - operand INVALID OPTION - aption INVALID DEVICE TYPE - addr INVALID SPOCLID - spoolid RADDR MISSING OR INVALID DEV addr DOES NOT EXIST {DEV ridltype raddr} OFFLINE type raddr ATTACHED TO userid type raddr IN USE BY SYSTEK COMMAND REJECTED; DEVICE raddr PENDING OFFLINE IBM VM/SP System Messages and Codes DMK SPMODE DMKSPM026E DP.KSPM804E DP.KSPM805E DMKSPM8081 OPERAND MISSING OR INVALID SINGLE PROCESSOR MODE ON REJECTED SINGLE PROCESSOR MODE OFP REJECTED SINGLE PROCESSCR HCDE ACTIV! SPTAPE DMKSPT199E COMMAND REJECTED; DEVICE raddr PENDING OFFLINE DMKSPS037E TAPE raddr INVALID FOR SPTAPE COMMAND SPOOL DMKCQH013E DMKCQH024E DMKCS0024E DMKCSP003E DMKCSP006E DMKCSP007E D~KCSP013E DMKCSP020E DKKCSP022E DMKCSP024E DMKCSP026E DMKCSP028E DMKCSP030E DHKCSP040E DMKCSP053E DMKCSP243E DMKCSP245E DMKCSP246E DMKCSP253E DMKCSQ024E DHKCSU024E DMKCSV013E DMKCSV024E DMKSPT024E DHKSPT032E CONFLICTING OPTION - option {CYLSIBLKSIFOEM NUHfER} MISSING {CYLSIBLKSIFORM NUMBER} MISSING INVALID OPTION - option INVALID DEVICE TYPE - addr INVALID USERID - userid CONFLICTING OPERAND - operand USERID MISSING OR INVALID VADDR MISSING OR INVALID {CYLSIBLKSIFORM NUHfER} MISSING OPERAND MISSING OR INVALID CLASS MISSING OR INVALID COPIES MISSING OR INVALID DEV addr DOES NOT EXIST userid NOT IN CP DIREC~ORY FLASH MISSING CR INVALID CHARS MISSING OR INVALID FCB MISSING OR INVALID MODIFY MISSING OR INVALID {CYLSIBLKSIFOEM NUHfER} MISSING {CYLSIBLKSIFOEM NUMBER} MISSING CONFLICTING OPTICN - option {CYLSIBLKSIFORM NUMBER} HISSING {CYLSIBLKSIFORH NUHfER} MISSING DISTCODE MISSING OR INVALID OR INVALID OR INVALID OR INVALID OR INVALID OR INVALID OR INVALID OR INVALID START DHKCS0003E DMKCS0006E DMKCS0013E DMKCS0021E DMKCS0028E DMKCS0040E DMKCS0046E DMKCS0140E DMKCS0243E DMKCS0245E DMKCS0246E DMKCS0253E INVALID OPTION - option INVALID DEVICE TYPE - addr CONFLICTING OPERAND - operand RADDR MISSING OR INVALID CLASS MISSING OR INVALID DEV addr DOES NOT EXIST type raddr OFFLINE type raddr ATTACHED TO userid FLASH MISSING OR INVALID CHARS MISSING CR INVALID FCB MISSING OR INVALID MODIFY MISSING OR INVALID STCP DMKCDS004S DMKCDS005E DMKCDS026E DMKCDS033E DMKCDS160E DMKCDS162E DMKCDS166E DMKVMA161E INVALID HEXLOC - bexloc INVALID HEXDATA - hexdata OPERAND MISSING OR INVALID HEXLOC MISSING OR INVALID HEXLOC bexloc EXCEEDS STORAGE INVALID ECR x - hexdata CHANGED SHARED PAGE NOT WRITTEN TO AUXILIARY STORAGE SHARED PAGE bexlcc ALTERED BY userid STORE DMKCDS004S DHKCDS005E DMKCDS010E DMKCDS012E DMKCDS026E DMKCDS033E DMKCDS160E DMKCDS162E DMKCDS163E DMKCDS164E DMKCDS166E INVALID HEXLOC - bexloc INVALID HEXDATA - bexdata INVALID REGISTER - register INVALID PSW - psw OPERAND MISSING OR INVALID HEXLOC MISSING OR INVALID HEXLOC bexloc EXCEEtS STORAGE INVALID ECR x - hexdata STORE EXCEEDS MAXIMUM REGISTER HEXLOC hexloc NON-ADDRESSAfLE STORAGE CHANGED SHARED PAGE NOT WRITTEN TO AUXILIARY STORAGE Appendix A. Command-to-Message Cross Reference 249 DMK DMKVMA181E SHARED SYSTEM name REPLACED WITH NON-SHARED COpy SYSTEM DMKCPB012E INVALID PSW - psw DMKCPB026E OPERAND MISSING OR INVALID TAG DMKCST003E DMKCST006E DMKCST022E DMKCST026E DMKCST027E DMKCSTOnOE DMKCST042E DMKCST424E INVALID OPTION - option INVALID DEVICE TIPE - addr VADDR MISSING OR INVALID OPERAND MISSING eR INVALID SPOOLID MISSING OR INVALID DEV addr DOES NO~ EIIST SPOOLID nnnn DOES NO~ EIIS~ RDR FILE SPCOL EBROE; IIIE UNCHANGED TERMINAL DMKCFT002E DMKCFT006E DMKGRF457E DMKCFT026E INVALID OPERAND - operand INVALID DEVICE TIPE - addr TERMINAL SCRNSAVE UNSUCCESSFUL OPERAND MISSING OR INVALID TRACE DMKTRA002E DMKTRA003E DMKTRA013E DMKTRA026E DMKTRA180E DMKVMA181E INVALID OPERAND - operand INVALID OPTION - option CONFLICTING OPERAND - operand OPERAND MISSING OE INVALID TRACE NOT IN EFFEC! SHARED SYSTEM name REPLACED WITH NCN-SHARED COPY TRANSFER DMKCSU003E INVALID OPTION - cption DMKCSU007E INVALID USERID - userid DMKCSU008~ INVALID SPOCIID - spoolid DMKCSU020E USERID MISSING OR INVALID DMKCSU026E OPERAND MISSING CE INVALID DMKCSU027E SPOOLID MISSING OR INVALID DMKCSU028E CLASS MISSING OR INVALID DMKCSU042E SPOOLID nnnn DOES NOT EllS! DMKCSU053E userid NOT IN CP DIRECTORY TRAPRED DMKTRR002E DMKTRR005E DMKTRR008E DMKTRR026E DMKTRR027E DMKTRR042E DMKTRR301E DMKTRR302E DMKTRR303E DMKTRR3051 DMKTRR764E INVALID OPERAND - operand INVALID HEIDATA - hexdata INVALID SPOCIID - spoolid OPERAND MISSING OR INVALID SPOOLID MISSING CB INVALID SPOOLID nnnn DOES NOT EllS! OR IS HELD REQUESTED FILE IS NCT A CPTRAP FILE I/O ERROR ON OOC - 1111111111 OOC READER IILE NeT LOCATAELE TRAPRED SELECTIVIil RESET ERROR IN ROUTINE 1111XI1X UNLOCK DMKCPV004S DMKCPV009E DMKCPV020E DMKCPV033E DMKCPVOn5E DMKCPV160E DMKCPV1651 DMKCPV176E DMKCPV202E DMKCPV203E DMKCPV204E INVALID HEXIOC - hexloc INVALID RANGE - range USERID MISSING OR INVALID HEXLOC MISSING OR INVALID userid NOT leGGED CN HEXLOC hexloc EXCEEDS STORAGE PAGE 'hexloc' NOT lCCKED; SHARED PAGE VIRTUAL = REAL AREA IN USE BY {USERIDISYSTEM} VIRT=REAL AREA NCT AVAILABLE; INSUFFICIENT STORAGE V=R AREA REQUIRES IPL EI DEVICE ADDRESS INVALID PAGES{S} SPECIFIED, V=R AREA VARY DMKCP0049E D!KCP012QE D!KCP0140E DMKCP01Q2E D!KCP0143E type DASD type type type 250 raddr raddr raddr raddr raddr IN USE IN USE E1 nnn USERS ATlACBED TO use~id NeT DEAINED IN USE B1 SlSTE! IBM VM/SP System Messages and Codes D!K DMKCP0198W DMKCPP6231 DMKCPT003E DMKCPT021E DMKCPT026E DMKCPT040E DMKCPT046E DMKCPT049E DMKCPT123E DMKCPT124E DMKCPT136E DMKCPT140E DMKCPT142E DMKCPT143E DMKCPT154E DMKCPT192E DMKCPU021E DMKCPU191E DMKCPU192E DMKCPU1931 DMKCPU1941 DMKCPU6231 DMKCPU812E DMKCPP6231 DMKCPT601E DMKCPT602E DMKMCT6251 VMDUMP DMKVMD009E DMKVMD013E DMKVMD020E DMKVMD033E DMKVMD038E DMKVMD053E DMKVMD1461 DMKVMD160E LAST PATH TO DEVICE raddr ON PROCESSOR nn CHANNEL SET CONNECTED TO PROCESSOR nn INVALID OPTION - cFtioD RADDR MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIST (DEV ridltype raddr) OFFLINE type raddr IN USE DASD raddr CP OWNED DASD raddr IN USE BY nDn USERS DEVICE (vaddrlraddr) NOT (DEFINEDIVARIED); CHANNEL XX DEDICATED type raddr ATTACBEt TO userid type raddr NOT DRAINED type raddr IN USE EY SYSTEM DEV raddr VARY FAILED, VARY IN PROCESS VARY PROCESSOR CCMMAND FAIIEt RADDR MISSING OR INVALID PROCESSOR nn DOES NOT EXIST VARY PROCESSOR COMMAND FAILED PROCESSOR nn ONLINE PROCESSOR nn OFFLINE CHANNEL SET CONNECTED TO PROCESSOR nn MSSF RESPONSE CODE TO VARY CP {ONIOFF} IS Dnnn CHANNEL SET CONNECTED TO PRCCESSOR nn CHANNEL CONTROL CBECK DEV xxx; USER 'userid' INTERFACE CONTEOl CBECK DEV xxx; USER 'userid' ALTERNATE PROCESSOR RECOVERY SUCCESSFUL; PROCESSOR nn OFFLINE INVALID RANGE - range CONFLICTING OPTION - option USERID MISSING OR INVALID HEXLOC MISSING OR INVALID PARAMETER parameter FOR option OPTION MISSING OR INVALID userid NOT IN CP IIEECTORY VMDUMP FAILED, SPOOLING ERROR HEXLOC hexloc EXCEEIS STORAGE WNG DMKMSG003E DMKMSG020E DMKMSG045E DMKMSG057W * INVALID OPTION - option USERID MISSING OR INVALID userid NOT LOGGED ON userid NOT RECEIVING; (DISCONNECTEDIMSG OFFliNG OFF) None. CP spontaneous Messages DMKRNH4541 DEV rid DISABLED DMKRNB4621 CTLR 'raddr' UNIT CBECK; IPl REQUIRED DMKRNB4631 CTLR 'raddr' UNIT CBECK; RESTART IN PROGRESS DMKRNH4641 CTLR 'raddr' CC=3; DEPRESS 370X "LOAD" BUTTON DMKRNB4651 LINE TRACE TERMINATED DUE TO ERROR Appendix A. Command-to-Message Cross Reference 251 DMS eMS Message Summary ACCESS DMSACC002E DMSACC003E DMSACC017E DMSACC048E DMSACC059E DMSACC060E DMSACC070E DMSACC109S DMSACC112S DMSACC113S DMSACC240S DMSACC230W DMSACC7231 DMSACC7241 DMSACC7251 DMSACC7261 DMSAC0230W FILE 'DMSROS ~EX~' NOT FOUND INVALID OPTION 'option' INVALID DEVICE ADERESS 'cuu' INVALID MODE 'mode' 'cuu' ALREADY ACCESSED AS READ/WRITE 'mode' DISK FILE{S} 'fn [ft [fm]]' NOT FCUND. DISK 'mode{cuu}' WILL NOT BE ACCESSED INVALID PARAMETEE 'parameter' VIRTUAL STORAGE CAPACliY EXCEEDED 'mode {cuu} , DEVICE ERROR 'mode {cuu} , NOT ATTACHED ERROR LOADING READ CS ROUTINE 'DMSROS TEXT' OS DISK-FILEle AND/OR OPTIONS SPECIFIED ARE IGNORED mode {cuu} {R/O I Ii/iI} [-OS I-DOS] 'cuu' REPLACES 'mode {cuu} , cuu ALSO = 'mode' [-OS I-DOS] DISK 'cuu mode [/ext]' RELEASED OSDISK - FILEID AND/OR OPTION SPECIFIED ARE IGNORED AMSERV DMSAMS001E DMSAMS002E DMSAMS003E DMSAMS006E DMSAMS007E DMSAMS065E DMSAMS066E DMSAMS070E DMSAMS109S DMSAMS113S DMSAMS136S DMSAMS228E DMSAMS367R DMSAMS7221 DMSSTT062E NO FILENAME SPECIPIED FILE 'fname1 A~S!RV' NCT FOUND INVALID OPTION 'oFtion' NO READ/WRITE DISR ACCESSED FOR 'fname2 LISTING' FILE 'fname1 AMS!RV fm' NOT FIXED, 80-CHAR. RECORDS 'option' OPTICN SPECIFIED TWICE 'option' AND 'option' ARE CONFLICTING OPTIONS INVALID PARAMETEF 'patameter' VIRTUAL STORAGE CAPACITY EXCEEDED {TAPIN I TAPOUT} {addr} NOT ATTACHED UNABLE TO LOAD 'IDCAMS' NO DDNAME ENTERED ENTER TAPE {INPU110UTPUT} DDNAMES: FILE 'fname2 LISTING fm' WILL HOLD AMSERV OUTPUT INVALID CHARACTER 'char' IN FILEID {'fname1 AMSERV'I'fname2 LISTING'} ASM3705 DMSARN001E DMSARN002E DMSARN003E DMSARN004W DMSARN006E DMSARN007E DMSARN008i1 DMSARN012W DMSARN016W DMSARX001E DMSARX002E DMSARX003E DMSARX006E DMSARX007E DMSARX038E DMSARX052E DMSARX070E DMSARX074E DMSARX075E NO FILENAME SPECIFIED FILE 'fn ft' NeT FOUND INVALID OPTION 'oFtion' WARNING MESSAGES ISSUED NO READ/WRI~E DISK ACCESSED FILE 'fn ft fm' IS NOT FIXED, 80 CHAR. RECORDS ERROR MESSAGES ISSUED SEVERE ERROR MESSAGES ISSUED TERMINAL ERROE MESSAGES ISSUED NO FILENAME SPECIFIED FILE 'fn ASM3705' NOT FOUND INVALID OPTION 'option' NO READ/WRITE DISK ACCESSED FILE 'fn ASM3705' IS NCT FIXED, 80-CHAR. RECORDS FILEID CONFLICT FOR DDNAME 'ASM3705' MORE THAN 100 CHARS. OF CPTIONS SPECIFIED INVALID PARAMETER 'Farameter' ERROR SETTING/RESETTING AUXILIARY tIRECTORY [DEVICE] devicename {INVALIDIILLEGAL} FOR {INPUTIOUTPUT} ASSEMBLE DMSASM001E DMSASM002E DMSASM003E DMSASM006E DMSASM007E DMSASM03SE DMSASM052E DMSASM070E DMSASM074E DMSASM075E NO FILENAME SPECIFIED FILE 'fn ASSEMELE' NOT FOUND INVALID OPTION 'option' NO READ/WRITE DISK ACCESSED FILE 'fn ASSE~EIE' IS NOT FIXED, SO-CHAR. RECORDS FILEID CONFLICT POR DDNAME 'ASSEMBLE' MORE THAN 100 CHARS. OF OPTIONS SPECIPIED INVALID PARAMETER 'Farameter' ERROR [RE]SETTING AUXILIARY tIRECTORY [DEVICE] devicename {INVAlIDIILLEGAl) FOR {INPUTIOUTPUT} 252 IEM VM/SP System Messages and Codes DMS ASSGN DMSASN003E DMSASN027E DMSASN028E DMSASN029E DMSASN035E DMSASN050E DMSASN065E DMSASN066E DMSASN069E DMSASN070E DMSASN087E DMSASN090E DMSASN099E DMSASN113S INVALID OPTION 'option' INVALID DEVICE 'device' NO LOGICAL UNI~ SPECIFIED INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD INVALID TAPE MODE PARAMETER MISSING AFTER SYSxxx 'option' OPTION SPECIFIED ~WICE 'option' AND 'option' ARE CONFLICTING OPTIONS DISK 'mode' NOT ACCESSED INVALID PARAMETER 'parameter' INVALID ASSIGNMENT OF 'SYSxxx' TO DEVICE 'device' INVALID DEVICE CLASS 'device class' FOR 'device' CMS/DOS ENVIRONMENT NO~ AC~IVE '{TAPnlmodeIREADERIPUNCHIPRINTER} {cuu} , NOT ATTACHED CMSEATCH DMSBTB100E DMSBTB101E DMSBTP105E DMSBTP106E DMSBTP107E DMSBTP108E DMSBTP109E NO BATCH PROCESSCR AVAILAEIE BATCH NOT LOADED NO JOB CARD PROVIDED JOB CARD FORMAT INVALID CP/CMS COMMAND 'command, {device}' NOT ALLOWED /SET CARD F'ORMAT INVALID {CPUIPRINTERIPUNCH} LIMIT EXCEEDED COMPARE DMSCMP002E DMSCMP003E DMSCMP005E DMSCMP009E DKSCMP010E DMSCMP011E DMSCHP019E DMSCMP029E DMSCMP054E DMSCMP062E DMSCMP069E DMSCMP104S DMSCMP109S DMSCHP1791 DMSCMP209W DHSCMP211E FILE 'fn [ft [fm]]' NOT FOUNt INVALID OPTION 'option' NO 'option' COLUMN SPECIFIED COLUMN 'col' EXCEEDS RECORD LENGTH PREMATURE EOF CN FILE ['fn ft [fm']] CONFLICTING FILE FORMATS IDENTICAL FILEIDS INVALID PARAMETER 'parameter' IN THE option 'COL' FIELD INCOMPLETE FILEID ['fn [ft]'] SPECIFIED INVALID * IN FILEID DISK 'mode' NOT ACCESSED ERROR Inn' READING FILE 'fn ft fm' FROM DISK VIRTUAL STORAGE CAPACITY EXCEEDED COMPARING 'fn ft fm' WITH 'fn ft fm' FILES DO NOT COMPARE COLUMN FIELDS CUT OF SEQUENCE COPY DMSCPY002E DMSCPY003E DMSCPY024E DMSCPY029E DMSCPY030E DMSCPY037E DMSCPY042E DMSCPY048E DMSCPY054E DMSCPY062E DHSCPY063E DMSCPY064E DMSCPY065E DMSCPY066E DMSCPY067E DMSCPY068E DMSCPY069E DMSCPY101S DHSCPY102S DMSCPY103S DMSCPY156E DMSCPY157E DHSCPY172E DMSCPY173E DMSCPY601R DMSCPY602R DMSCPY7211 DHSCPY901T DMSCPY903T [INPUTIOVERLAY] FIIE[ {S}] ['fn [ft [fm]]'] NOT FOUND INVALID OPTION 'cption' FILE 'fn ft fm' ALREADY EXISTS, SPECIFY 'REPLACE' INVALID PARAMETER 'parameter' IN THE 'option' OPTION FIELD FILE 'fn ft fm' ALREADY ACTIVE DISK 'mode[ {cuu}]' IS READ/ONLY NO FILEID[ {S}] SPECIFIED INVALID MODE 'mode' INCOMPLETE FILEIC SPECIFIED INVALID CHAR '[=I*lchar]' IN FILEID '[fn ft fm]' NO [ {TRANSLATION I SPECIFICATION} ] lIST ENTERED INVALID [TRANSLATICN] SPECIFICATION AT OR NEAR , •••••••• , 'option' OPTION SPECIFIED TWICE 'option' AND 'option' ARE CONFLICTING OPTIONS COMBINED INPUT FILES ILLEGAL WITH PACK OR UNPACK OPTIONS INPUT FILE 'fn ft fm' NOT IN PACKED FORHAT DISK MODE NOT ACCESSED SPECS TEMP STRING STORAGE EXHAUSTED AT , •••••••• TOO MANY FIIEIDS NUMBER OF SPECS EXCEEDS MAX 20 'FROM nnn' NOT FOUND --FILE 'fn ft fm' HAS ONLY 'nnn' RECORDS LABEL 'label' NOT FOUND IN FILE 'fn ft fm' TOLABEL 'label' {EQUALSI IS AN INITIAL SUBSTRING OF} FRLABEL 'label' NO RECORDS WERE COPIED TO OUTPUT FILE 'fn ft fm' ENTER SPECIFICATICN LIST: ENTER TRANSLATION LIST: COPY 'fn ft fm' [{TCIAPPENDICVLY} 'fn ft fm' {OLDINEW} FILE] UNEXPECTED ERROR AT 'addr': PLIST 'plist' AT 'addr', BASE 'addr', RC Inn' IMPOSSIBLE PHASE CODE 'hh' Appendix A. Command-to-Hessage Cross Reference 253 D"S D"SCPY904T UNEXPECTED UNPACK ERROE AT 'addr', BASE 'addr' CPEREP D"SIFC002E D"SIFC007E D"SIFC023E D"SIFC070E DMSIFC104S D"SIFC825E DMSIFC826E D"SIFC828I DMSIFC829W DMSIFC831E DMSREA830E D"SIFC832S FILE 'fn ft [fm]' NOT FOUND FILE 'fn ft fm' IS NOT FIXED, 80 CHAR. BECOEDS NO FILETYPE SPECI!IED INVALID PARAMETER 'parameter' ERROR 'nne READING FILE 'fn ft fm' FROM DISK CLEAR IS VALID ONLY WHEN SPECIFIED BY ITSELF EREP TXTLIBS NOT FOUND CPEREP ZERO OE CLEAR HAS EEEN COMPLETED ATTEMPTED 'ZERO' iAS SUPPRESSED. REQUIRES PEIVILEGE CLASS F MORE THAN 100 CHAES. OF OPTICNS SPECIFIED I/O ERROR READING A BLOCK OF RECORDS FROM THE ERROE RECORDING CYLINDERS SOFTWARE INCOMPATIEILITY AT THE CPEREP-EREP INTERFACE. CODE=nnn DEBUG DMSDBG113S PRINTER {cuu} NOT ATTACHED DMSDEG728I DEBUG ENTERED [EXTERNAL INTIEREAKPCINT nn AT xxxxxx] DEFAULTS DMSWDF014E DMSWDF029E DMSWDF637E DMSWDF641E DMSWDF642E INVALID KEYWOED 'function' INVAVID PARAMETER 'parameter' IN THE OPTION 'option' FIELD MISSING VALUE FOR THE {PROFIIEIFROMIFOEINOTEBOOK} OPTION NO {OPTIONSICOMMAND} SPECIFIED DEFAULTS DOES NOT ACCEPT {'CCMMAND' commandl'OPTION' option for 'COMMAND'} DMSWDF653E ERROR EXECUTING 'GlCBAIV' DMSSTT062E INVALID CHARACTER 'character' IN FIIEID 'fn ft fm' DISCARD DMSWDC651E DISCARD MUST BE ISSUED FOR RDRLIST, PEEK OR FILELIST DMSWDC652E MISSING OPERAND{S}. SPECIFY 'EXECUTE en] DISCARD' DMSWDC653E ERROR EXECUTING 'command', RC - Inn' DISK DMSDSKOO 2E DMSDSK014E DMSDSK037E DMSDSK047E DMSDSK048E DMSDSK054E DMSDSK062E DMSDSK070E DMSDSK077E DMSDSK078E DMSDSK078W DMSDSK104S DMSDSK105S DMSDSK118S DMSDSK124S DMSDSK205W DMSDSK445W DMSDSK496S DMSDSK550W DLBL DMSDLB001E DMSDLE003E DMSDLB005E DMSDLB023E DMSDLB048E DMSDLE050E DMSDLB065E DMSDLB066E DMSDLB069E DMSDLB070E DMSDLB086E DMSDLB109S DMSDLB220R DMSDLB221E 254 FILE[ {S}] [' fn [ft [fm]]' ) NO'! FOUND INVALID FUNCTICN 'function' DISK 'mode[ {cuu}]' IS EEAD/ONLY NO FUNCTION SPECIFIED INVALID MODE 'mode' INCOMPLETE FILEIE SPECIFIEt INVALID IN FILEID ['fn ft fm'] INVALID PARAMETER 'parameter' END CARD MISSING FROM INPUT DECK INVALID CARt IN INPUT tECK SEQUENCE ERROR DE~ECTED LOADING 'fn ft' EXPECTED' FOUND ' ERROR 'nnw READING FILE 'fn ft fm' FROM DISK ERROR 'nne WRITING FILE 'fn ft fm' ON DISK ERROR PUNCHING FILE ERROR READING CAED FILE READER EMPTY CE NOT READY INVALID DAT IN SEQUENCE FIELD, BYPASSING SEQUENCE CHECK READER FILE ALTERED TO DISK LOAD AS: 'fn ft fm'. DISK LOAD STOPPED. FILE HAS BEEN LEFT IN YOUR READER DATE/TIME DATA NCT PRESENT FCE FILE 'fn ft' * NO FILENAME SPECIIIED INVALID OPTION 'cFtion' NO '{CATIBUFSP}, SFECIFIED NO FILETYPE SPECIIIED INVALID MODE 'mode' PARAMETER MISSING AFTER DDNAME 'option' OPTICN SPECIFIED TWICE 'option' AND 'option' ARE CONFLIC~ING OPTIONS DISK 'mode' NOT ACCESSED INVALID PARAMETER 'parameter' INVALID DDNAME 'ddname' VIRTUAL STORAGE CAPACI'!Y EXCEEDED ENTER DATA SET NAME: INVALID DATA SET NAME lEft VM/SP System Messages and Codes DMS DMSDLB301E DMSDLB302E DMSDLE304E DMSDLB30SE DMSDLB306E DMSDLB307E DMSDLE308E DMSDLB3201 DMSDLB3211 DMSDLB3221 DMSDLB3231 DMSDLB3241 DMSDLE330R DMSDLB331R 'SYSxxx' NOT ASSIGNED FCR EISK 'fm' NO SYSXXX OPERAND SFECIPIED INVALID OPERAND VALUE 'value' INCOMPLETE EXTENT RANGE SYSxxx NOT ASSIGNED FOR 'IGNORE' CATALOG DDNAME 'ddname' NeT FCUND 'mode' DISK IN [NON-]CMS FCRMAT: INVALID FOR [NON-]CMS DATASET MAXIMUM NUMEER OF DISK ENTEIES RECORDED MAXIMUM NUMEER OF EXTENTS RECORDED DDNAME 'ddname' NeT FOUND: NO CLEAR EXECUTED {MASTERIJOE} CATALOG DLEL CLEARED NO USER DEFINED DIEI's IN EFFECT ENTER VOLUME SPECIFICATIONS: ENTER EXTENT SPECIFICATIONS: DOSLIB DMSDSL002E DMSDSL003E DMSDSL013W DMSDSL014E DMSDSL037E DMSDSL046E DMSDSL047E DMSDSL069E DMSDSL070E DMSDSL098E DMSDSL104S DMSDSL10SS DMSDSL213W FILE 'fn DOSLIE' NCT FCUND INVALID OPTION 'cption' PHASE 'phase' NOT FCUND IN LIBRARY 'fn DOSLIB fm' INVALID FUNCTION 'function' DISK 'mode' IS READ/ONLY NO LIBRARY NAME SPECIFIED NO FUNCTION SPECIFIED DISK 'mode' NOT ACCESSED INVALID PARAMETEE 'parameter' NO PHASE NAME SPECIFIED ERROR Inn' READING FILE 'fn DOSLIB fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK LIERARY 'fn DOSLIE fm' NCT CREATED DOSLKED DMSDLK001E DMSDLK003E DMSDLK006E DMSDLK007E DMSDLK070E DMSDLK099E DMSDLK104S DMSDLK10SS DMSDLK210E DMSDLK24SS NO FILENAME SPECIFIED INVALID OPTION 'cption' NO READ/WRITE DISK ACCESSED FILE 'fn ft fm' IS NOT FIXED, 80 CHAR. RECORDS INVALID PARAMETEF 'parameter' CMS/DOS ENVIRONMENT NOT ACTIVE ERROR Inn' READING FILE 'fn ft fm' FROM DISK ERROR 'nnw WRITING FILE 'fn ft fm' ON DISK LIBRARY 'fn ft' IS ON A READ-ONLY DISK ERROR 'nnn' ON PRINTER DSERV DMSDSV003E DMSDSV021W DMSDSV022W DMSDSV023W DMSDSV024W DMSDSV02SW DMSDSV026W DMSDSV027E DMSDSV027W DMSDSV028W DMSDSV047B DMSDSV06SE DMSDSV066E DMSDSV070E DMSDSV09SE DMSDSV099E DMSDSV105S DMSDSV24SS INVALID OPTION 'option' NO TRANSIENT DIRECTORY NO CORE IMAGE DIRECTORY NO RELOCATABLE DIRECTORY NO PROCEDURE DIRECTCRY NO SOURCE STATEMENT DIRECTORY 'phase' NOT IN LIERARY INVALID DEVICE 'nnw NO PRIVATE CORE IMAGE LIERARY NO {PRIVATEISYSTEM} TRANSIENT DIRECTORY ENTRIES NO FUNCTION SPECIFIED 'option' OPTION SPECIFIED TWICE 'option' AND 'option' ARE CONFLICTING OPTIONS INVALID PARAMETER 'parameter' INVALID ADDRESS 'address' CMS/DOS ENVIRONMENT NOT ACTIVE ERROR Inn' WRITING FILE 'DSERV MAP AS' ON DISK ERROR 'nnn' ON PRINTER EDIT DMSEDI003E DMSEDI024E DMSEDI029E DMSEDI044E DMSEDIOS4E DMSEDI069E DMSEDI076E DMSEDI104S DMSEDI105S DMSEDI117S INVALID OPTION 'option' FILE 'fn ft fm' ALREADY EXISTS INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD RECORD LENGTH EXCEEDS ALLOWAELE MAXIMUM INCOMPLETE FILEID ['fn [ft]'] SPECIFIED DISK 'mode' NCT ACCESSED ACTUAL RECORD LENGTH EXCEEDS THAT SPECIFIED ERROR Inn' READING FILE 'fn ft fm' FBOM DISK ERROR 'nn' WRITING PILE 'fn ft fm' ON DISK ERROR WRITING TO DISPLAY TERMINAL Appendix A. Command-to-Message Cross Reference 255 DKS DKSEDI132S FILE 'fn ft fm' Tec LAEGE DMSEDI143S UNABLE TO LOAD SAVED SYSTEM OR LOAD KODULE DKSEDI144S REQUESTED FILE IS IN ACTIVE STATUS ERASE DKSERS002E DMSERS003E DMSERS037E DMSERS048E DMSERS054E DMSERS069E DMSERS070E DMSERS071E DMSERS109T FILE[ {S}] ['fn [ft [fm)]'] NOT FOUND INVALID OPTION 'oFtion' DISK 'mode {cuu} , IS READ/ONLY INVALID MODE 'mode' INCOl!!PLETE FILEID ['fn [ft]'] SPECIFIED DISK 'mode' NO~ ACCESSED INVALID PARAMETER 'parameter' ERASE * * [fml*] NCT AILCWED VIRTUAL STORAGE CAPACI~Y EXCEEDED ESERV DMSERV001E DMSERV002E DMSERV006E DMSERV027E DMSERV037E DMSERV070E DMSERV099E NO FILENAME SPECIFIED FILE 'fn ESERV' NCT FOUND NO READ/WRITE DISK ACCESSED INVALID DEVICE 'device' FOE SYSxxx DISK 'mode' IS READ/ONLY INVALID ARGUMENT 'argument' CMS/DOS ENVIRONMEN~ NOl AC~IVE EXEC DMSEXC001E NO FILENAME SPECIFIED DMSEXT072E ERROR IN EXEC FILE fn, LINE nnn - message EXECIO DMSEI0618E DMSEI0621E DMSEI0622E DMSEI0632E NUCEXT FAILED BAD PLIST: xxxxx INSUFFICIENT FREE STeRAGE ICE EXECIO I/O ERROR IN EXECIO: RC=nnn FROM 'command' COMMAND EXECUTE DMSWEX526E OPTION 'CURSOR' VALID IN DIS FLAY MCDE ONLY DMSWEX561E CURSOR IS NCT ON A VAlID DATA FIELD DMSWEX654E INVALID SYMBOL 'symbol' {I/O' MUST BE SPECIFIED ALONEI INVALID CHARACTER 'char' FCIIOWING 'I' SYMEOL} Dl!!SWEX651E 'EXECUTE' MUST BE ISSUED FROK FILELIST OR RDRLIST EXEC 2 DMSEXE085E ERROR IN fn ft fm, LINE nnn - message DMSEXE175E INVALID EXEC COMMAND DMSEXE255T INSUFFICIENT S~ORAGE FOR EXEC INTERPRETER FETCH DMSFCH016E DMSFCH104S DMSFCH109S DMSFCH113S DMSFCH115E DMSFCH411S Dl!!SFCH623S DKSFCH777S DMSFET003E Dl!!SFET004E DMSFET029E DMSFET070E DMSFET098E DMSFET099E DMSFET623S DMSFET710I DMSLI0055E DKSLI07401 FILEDEF DMSFLD003E DHSFLD023E DMSFLD027E DMSFLD029E 256 NO PRIVATE CORE IMAGE LIBRARY FOUND ERROR Inn' READING FILE 'fn ft fm' FROM DISK VIRTUAL STORAGE CAPACI~Y EXCEEDED DISK {cuu} NOT ATTACHED PHASE LOAD POINT LESS ~HAN 'address' INPUT ERROR CODE Inn' ON {S!SRESISYSCLB} PHASE CANNOT BE LOADED AT lOCATION 'location' BECAUSE IT WOULD OVERLAY THE CKS NUCLEUS DOS PARTITION TOO SMALL TO ACCOKMODATE FETCB REQUEST INVALID OPTION 'option' PHASE 'phase' NOT FCUND INVALID PARAMETER 'parameter' IN THE OPTION 'ORIGIN' FIELD INVALID PARAMETEE 'parameter' NO PHASE NAKE SPECIFIED CMS/DOS ENVIRONMEn NOT ACTIVE PHASE CANNOT BE LOADED AT LOCATION 'location' BECAUSE IT WOULD OVERLAY THE CMS NUCLEUS PHASE 'phase' ENTRY POlNT AT LOCATION xxxxxx NO ENTRY POINT DEFINED EXECUTION BEGINS ••• INVALID OPTION 'option' NO FILETYPE SPECIFIED INVALID DEVICE 'device name' INVALID PARAMETER 'parameter' IN TBE OPTION 'option' FIELP IBM VM/SP System Messages and Codes DMS DMSFLD035E DMSFLD050E DMSFLD065E DMSFLD066E DMSFLD0691 DMSFLD070E DMSFLD220R DMSFLD221E DMSFLD224E DMSFLD420E DMSFLD7041 DMSSTT2281 DMSFLD3241 FILELIST DMSWFL002E DMSWFL003E DMSWFL054E DMSWFL070E DMSWFL680E DMSWFL637E DMSWFL651E DMSSTT062E INVALID TAPE MCDE PARAMETER MISSING AFTER DDNA!E 'option' OPTICN SPECIFIED TWICE 'option' AND 'option' ARE CONFLICTING OPTIONS DISK 'mode' NOT ACCESSED ' INVALID PARAMETER 'parameter' ENTER DATA SET NAME: INVALID DATA SET NAME 'data set name' FILEID ALREADY IN USE NSL EXIT FILENAME MISSING OR INVALID INVALID CLEAR REQUEST USER LABELS BYPASSED ON DATA SET 'data set name' NO USER DEFINED FILEDEI's IN EFFECT FILE 'fn ft fm' NeT FOUND INVALID OPTION 'cFtion' INCOMPLETE FILElt SPECIFIED INVALID PARAMETER 'Farameter' INVALID FILEID SPECIFIED WITE 'FILELIST' OPTION MISSING VALUE FOR THE 'PROFILE' OPTION 'APPEND' MUST BE ISSUED FOB RDRLIST OR FILELIST INVALID CHARACTER 'character' IN FILEID 'fn ft fm' FORMA~ DMSFOR003E DMSFOR005E DMSFOR017E DMSFOR028E DMSFOR037E DMSFOB048E DMSFOR069E DMSFOR070E DMSFOR113S DMSFOR114S DMSFOR125S DMSFOR114S DMSFOR126S DMSFOR214W DMSFOR216E DMSFOR603R DMSFOR605R DMSFOE7051 DMSFOR7321 DMSFOR7321 DMSFOR733I INVALID OPTION 'option' NO 'option' SPECIFIED INVALID DEVICE AttRESS 'cuu' NO DEVICE SPECIFIED DISK 'mode[ {cuu}]' IS READ/ONLY INVALID MODE 'mode' DISK {'mode'l'cuu'} NOT ACCESSED INVALID PARAMETEE 'parameter' {TAPn{cuu} Imode{cuu}IREADERIPUNCHIPRINTER} NOT ATTACHED 'cuu' IS AN UNSUPPORTED DEVICE TYPE PERMANENT UNIT CHECK ON DISK 'mode{cuu}' 'cuu' IS AN UNSUPPORTED DEVICE, OR REQUESTED BLKSIZE IS NOT SUPPORTED FOR THE DEVICE ERROR {READIWRIT}ING LABEL ON DISK 'mode{cuu}' CANNOT RECOMPUTE WITHOUT LOSS OF DATA. NO CHANGE. INSUFFICIENT BLOCKS ON DISK TO SUPPORT CMS DISK STRUCTURE FORMAT WILL ERASE ALL FILES ON DISK 'mode{cuu}'. DO YOU WISH TO CONTINUE? {YESINO}: ENTER DISK LABEL: DISK REMAINS UNCHANGED 'nnn' CYLINDERS FORMATTED ON DISK 'mode{cuu}' 'nnn' {CYLINDERSIFE-512 BLCCKS} FeRMATTED ON DISK 'mode{cuu}' FORMATTING DISK 'mode' GENDIRT DMSGND002W DMSGND021E DMSGND022E DMSGND070E FILE[ {S}] ['fn eft [fm]]'] NCT FOUND ENTRY POINT 'name' NOT FOUND NO DIRECTORY NAME SPECIFIED INVALID PARAMETER 'parameter' GENMOD DMSMOD003E DMSMOD005E DMSMOD021E DMSMOD032E DMSMOD037E DMSMOD040E DMSMOD070E DMSMOD084E DMSMOD105S DMSSTT048E DMSSTT069E INVALID OPTION 'cFtion' NO '{FROMITO} ENTRY' SPECIFIED ENTRY POINT 'name' NOT FOUND INVALID FILETYPE eft' DISK 'mode' IS READ/ONLY NO FILES LOADED INVALID PARAMETER 'parameter' INVALID USE OF 'FHOM' ANt 'TC' OPTIONS ERROR 'nn' WRITING FILE 'fn ft fm' ON DISK INVALID MODE 'mode' DISK 'mode' NOT ACCESSED Appendix A. Command-to-Message Cross Reference 257 DMS GEN3705 DMSGRN002E DMSGRN003E DMSGRN007E DMSGRN048E DMSGRN054E DMSGRN078E FILE 'fn ft [fm]' NOT FOUND INVALID OPTION 'o~tion' FILE 'fn ft' IS NOT FIXED, 80 CHAR. RECORDS INVALID MODE 'mode' INCOMPLETE FILElt SPECIFIED INVALID CARD IN INPUT FILE '80 character card image' GLOllAL DMSGLB002W DMSGLB014B DMSGLB047E DMSGLB108S FILE 'fn ft' NOT FCUND INVALID FUNCTION 'function' NO FUNCTION SPECIFIED MORE THAN 8 LIERARIES SPECIFIED GLOBALV DMSGL0047E DMSGL0104S DMSGLC618E DMSGL0622E DMSGL0628E DMSGL0631E DMSGL0649E NO FUNCTION SPECIFIED ERROR Inn' READING FILE 'fn ft fm' FROM DISK NUCEXT FAILED INSUFFICIENT FREE STORAGE - NO TAELE MADE INVALID GLOBALV FUNCTION 'function' SETL/SETLP/SETLS CAN ONLY BE EXECUTED FROM AN EXEC 2 EXEC OR AS A CMS COMMAND EXTRANEOUS PARAMETER 'parameter' HELP DMSHLP002E DMSHLP003E DMSHLP104S DMSHLP109S DMSHLP250S DMSHLP251E DMSHLP252E DMSHLP254E DMSHEL529E DMSHEL545E DMSHEL561E DMSHEL640E DMSHLP907T INPUT FILE{S} 'fn ft fm' NOT FOUND INVALID OPTION 'option' ERROR Inn' READING FILE 'fn ft fm' FROM DISK VIRTUAL STORAGE CAPACI!Y EXCEEDED I/O ERROR OR DEVICE ERROR HELP PROCESSING ERROR CODE nn - 'description' VALID OPTIONS ARE = DESC FORM PARM ALL HELP CANNOT FIND THE INFORMA!ION YOU REQUESTED. IF NOT MISSPELLED, PLEASE ENTER 'HELP' FOR MENU SELECTION OR 'HELP HELP' FOR THE HELP CCMMAND 'subcommand' SUBCOMMAND IS ONLY VALID IN EDITING MODE MISSING OPERAND{S} CURSOR IS NOT ON A VALID DATA FIELD UNABLE TO ACCESS HELP DISK {cuu}, RC=nn FROM ACCESS COMMAND I/O ERROR ON FILE 'fn ft fm' IDENTIFY DMSIDE003E DMSIDE056E DMSIDE070E DMSIDE104S INVALID OPTION Inn' FILE 'fn ft' CONTAINS INVAlID RECORD FORMAT INVALID pARAMETER 'parameter' ERROR 'nnw READING FILE 'fn ft fm' FROM DISK IMAGHIOD DMSIMA001E DMSIMA002E DMSIMA003E DMSIMA013E DMSIMA014E DMSIMA046E DMSIMA047E DMSIMA346E DMSIMA347E DMSIMA348E DMSIMA349E DMSIMA751E NO FILENAME SPECIFIED FILE 'fn ft' NOT FOUND INVALID OPTION 'option' MEMBER 'name' NOT FOUND IN LIBRARY 'llbname' INVALID FUNCTICN 'function' NO LIBRARY NAME SPECIFIED NO FUNCTION SPECIFIED ERROR'nn' LOADING 'fn ft' FROM DISK ERROR Inn' LOADING LIBRARY 'libname' ERROR 'nnw SAVING LIBRARY 'litname' INVALID LIBRARY 'libname' MEMBER 'name' FOUND IN LIBRARY 'libname' INCLUDE DMSLGT0021 DMSLI0001E DMSLI0002E DMSLI0003E DMSLI0005E DMSLI0021E DMS~I0029E DMSLI0055E DMSLI0056E DMSLI0099E DMSLI0104S DMSLI0105S 258 FILE 'fn TXTLIB' NO! FOUND NO FILENAME SPECIFIED FILE ['fn [ft [fm]]'] NOT FOUND INVALID OPTION 'option' NO 'option' SPECIFIED ENTRY POINT 'name' NCT FOUND INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD NO ENTRY POINT DEFINED FILE 'fn ft fm' CONTAINS INVALID RECORD FORMATS CMS/DOS ENVIRONMENT ACTIVE ERROR Inn' READING FILE 'fn ft tm' FROM DISK ERROR 'nn' WRITING FILE 'fn ft fm' ON DISK IBM VM/SP System Messages and Codes DMS DftSLI0109S DMSLI0116S DMSLI0168S DftSLI0169S DftSLI0201W DftSLI0202W DMSLI0203W DMSLI0206W D8SLI0623S VIRTUAL STORAGE CAPACITY EXCEEDED LOADER TABLE CVEElLCW PSEUDO REGISTER TABLE OVERFLOW ESDID TABLE CVERFLOW THE FOLLOWING NAMES ARE UNDEFINED: DUPLICATE IDENTIFIER 'identifier' "SET LOCATION COUNTER" NAME 'name' UNDEFINED PSEUDO REGISTER ALIGNMENT ERROR MODULE CANNOT BE LOADED AT LOCATION 'location' BECAUSE IT WOULD OVERLAY THE CMS NUCLEUS DMSLI07401 EXECUTION BEGINS ••• DMSLI0907T I/O ERROR ON FILE 'fn ft fm' IOCP DMSICP001E DMKICP002E DMSICP003E DMSICP006E DMSICP007E DMSICP038E DMSICP070E DMSICP075E DMSICP099E NO FILENAME SPECIFIED FILE 'filename' IOCP NCT FCUND INVALID OPTION 'o~tion' NO READ/WRITE DISK ACCESSEt FILE 'filename' IOCP IS NOT FIXED, 80 CHAR. RECORDS FILEID CONFLICT FCR DDNAME 'SYSIN' INVALID PARAMETER '~arameter' [DEVICE] devicename INVALlt FOR (INPUTIOUTPUT} CMS/DOS ENVIRONMENT ACTIVE LABELDEF DMSLBD003E DMSLBD029E DMSLBD065E DMSLBD066E DMSLBD070E DMSLBD221E DMSLBD3241 DMSLBD7041 INVALID OPTION - o~tion INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD 'option' OPTICN SPECIFIEt TWICE 'option' and 'option' ARE CONFLICTING OPTIONS INVALID PARAMETER 'parameter' INVALID DATA SET NAME NO USER DEFINED lAEELDEF's IN EFFECT INVALID CLEAR REQUEST LISTDS DMSLDS002E DMSLDS003E DMSLDS048E DMSLDS069E DMSLDS220R DMSLDS221E DMSLDS222E DMSLDS223E DMSLDS226E DMSLDS227W DMSLDS229I DMSLDS231E DMSLDS2331 DATA SET NOT FOUND INVALID OPTION 'oFtion' INVALID MODE 'mode' DISK 'mode' NCT ACCESSED ENTER DATA SET NAME: INVALID DATA SET NAME I/O ERROR READING 'data set name' FROM ('fm'IOSIDOS} DISK NO FILEMODE SPECIFIED NO DATA SET NAME ALLOWED WITH FREE OPTION INVALID EXTENT FCUND FOR 'datasetname' ON {'fm'IOSIDOS} DISK NO MEMBERS FOUND I/O ERROR READING VTOC FRCM 'fm' DISK NO FREE SPACE AVAILABLE ON 'fm' DISK LISTFILE DMSLST002E DMSLST003E DMSLST037E DMSLST048E DMSLST066E DMSLST069E DMSLST070E DMSLST105S FILE NOT FCUND INVALID OPTICN 'oFtion' DISK 'mode[ {cuu}]' IS READ/ONLY INVALID MODE 'mode' 'option' and 'opticn' ARE CONFLICTING OPTIONS DISK {'mode'l 'cuu'} NOT ACCESSED INVALID PARAMETER 'parameter' ERROR 'nnw WRITING FILE 'fn ft fm' ON DISK LISTIO DMSLLU003E DMSLLU006E DMSLLU070E DMSLLU099E DMSLLU105S DMSLLU303E INVALID OPTION 'option' NO READ/WRITE 'A' DISK ACCESSED INVALID PARAMETER '~arameter' CMS/DOS ENVIRONMENT NOT ACTIVE ERROR Inn' WRITING FILE '$LISTIO EXEC A1' ON DISK NO SYSXXX SATISFIES RECUEST LKED DMSLKD001E DMSLKD002E DMSLKD004W D8SLKD005E DMSLKD006E NO FILENAME SPECIFIED FILE 'fn ft' NOT FOUND WARNING MESSAGES ISSUED NO 'keyword' SPECIFIED NO READ/WRITE DISK ACCESSED Appendix A. Command-to-Message Cross Reference 259 DMS DMSLKD007E DMSLKD008W DMSLKD012W DHSLKD016W DMSLKD070E FILE 'fn ft' IS NeT FIXED, 80-CHAR. RECORDS ERROR MESSAGES ISSUED SEVERE ERROR MESSAGES ISSUED TERMINAL ERROR MESSAGES ISSUED INVALID PARAMETEE 'parameter' LOAD DMSLGT0021 DMSLI0001E DMSLI0002E DMSLI0003E DMSLI0005E DMSLI0021E DMSLI0029E DMSLI0055E DMSLI0056E DMSLI0099E DMSLI0104S DMSLI0105S DMSLI0109S DMSLI0116S DMSLI0168S DMSLI0169S DMSLI0201W DMSLI0202W DMSLI0203W DMSLI0206W DMSLI0623S FILE 'fn' TXTLIB NCT FCUND NO FILENAME SPECIFIED FILE[ {S}] ['fn Eft [fm]]'] NOT FOUND INVALID OPTION 'option' NO 'option' SPECIFIED ENTRY POINT 'name' NOT FOUND INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD NO ENTRY POINT DEFINED FILE 'fn ft fm' CONTAINS INVALID RECORD FORMATS CMS/DOS ENVIRCNMEN'I ACTIVE ERROR Inn' REAtING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK VIRTUAL STORAGE CAPACITY EXCEEDED LOADER TABLE CVERFLew PSEUDO REGIS!ER TABLE OVERFLCW ESDID TABLE OVERFlCW THE FOLLOWING NAMES ARE UNDEFINED: DUPLICATE IDENTIF1ER 'IDENTIFIER' "SET LOCATION COUNTER" NAME 'name' UNDEFINED PSEUDO REGISTER AlIGNMENT ERECR MODULE CANNOT BE LOADED AT LOCATION 'location' BECAUSE IT WOULD OVERLAY THE CMS NUClEUS DMSLI0740I EXECUTION BEGINS ••• DMSLI0907T I/O ERROR ON FILE 'fn ft fm' DMSSTT062E INVALID * IN FILE1D LOAtHOD DMSMOD001E DMSMOD002E DMSMOD032E DMSMOD070E DMSMOD104S DMSMOD109S DMSMOD114E DMSMOD116S DMSSLN002E DMSSLN104E DMSSTT048E NO FILENAME SPECIFIED FILE ['fn [ft]'] NCT FCUND INVALID FILETYPE 'ft' INVALID PARAMETER 'parameter' ERROR 'nn' READING FILE 'fn ft fm' FROM DISK VIRTUAL STORAGE CAPACITY EXCEEDED 'fn ft fm' NOT LOADED; CMS/DOS ENVIRONMENT [NOT] ACTIVE LOADER TABLE CVEEFLCW FILE 'fn ft' NOT FOUND ERROR Inn' READING FILE 'fn ft fm' FROM DISK INVALID MODE 'modE' MACLIB DMSLBM001E DMSLBM002E DMSLBM002W DHSLBM003E DMSLBM013W DMSLBM014E DHSLBM037E DHSLBM046E DHSLBM047E DHSLBM056E DHSLEM069E DMSLBM070E DHSLBM104S DMSLBM105S DHSLBM109S DMSLBM157S DMSLBM167S DMSLBM213W DP.SLBM907T NO FILENAME SPECIFIED FILE ['fn Eft]'] NCT FCUND FILE 'fn ft [fmJ' NOT FOUND INVALID OPTION 'cFtion' MEMBER 'name' NOT FOUND IN LIBRARY 'fn ft fm' INVALID FUNCTICN 'function' DISK 'mode[ {cuu}]' IS READ/ONLY NO LIBRARY NAME S~ECIFIED NO FUNCTION SPECIFIED FILE 'fn ft fm' CeNTAINS INVALID RECORD FORMATS DISK 'mode' NOT ACCESSED INVALID PARAMETER 'parameter' ERROR 'nn' READING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK VIRTUAL STORAGE CAPACITY EXCEEDED MACLIB LIMIT EXCEEDED [, LAST MEMBER NAME ADDED WAS 'membername'] PREVIOUS MACLIB FUNCTION NOT FINISHED LIBRARY 'fn ft fm' NOT CREATED I/O ERROR ON FILE 'fn ft fm' MODMAP DMSMDP001E DMSMDP002E DMSMDP018E DMSMDP070E NO FILENAME SPECIFIED FILE ['fn [ft [fm]]'] NOT FOUND NO LOAD MAP AVAILABLE INVALID PARAMETER 'parameter' 260 IBM VM/SP System Messages and Codes D!S ftOVEFILE DftSMVE002E DftSMVE003E DMSMVE037E DftSMVE041E DftSftVB069B DftSftVE070E DMSMVE073E DMSMVE075E DMSMVE086E DftSMVE127S DMSMVE128S DMSMVE129S DMSMVE130S DMSMVE2251 DMSMVE2261 DMSftVE232E DftSMVE7061 DftSMVE7081 FILE[ (S) ]['fn [ft [fm]]'] NOT FOUND INVALID OPTION 'option' OUTPUT DISK 'mode' IS EEAD/CNLY INPUT AND OUTPUT FILES ARE TEE SA!E OUTPUT DISK 'mode' IS NOT ACCESSED INVALID PARAftETER 'parameter' UNABLE TO OPEN FILE ddname DEVICE 'device name' ILLEGAL FOR {INPUTIOUTPUT) INVALID DDNAME 'ddname' UNSUPPORTED DEVICE FOR 'ddname' I/O ERROR ON INPUT AFTER READING 'nnnn' RECORDS: INPUT ERROR CODE code ON ddname I/O ERROR ON OUTPUT WRITING RECORD NUMBER 'nnnn': OUTPUT ERROR code ON ddname BLOCKSIZE ON V FORMAT FILE 'ddname' IS LESS THAN 9 PDS MEMBER 'membername' MOVED END OF PDS MOVE INVALID RECFM -- SFANNED RECORDS NeT SUPPORTED TERM INPUT -- TYPE NULL LINE FOR END OF DATA DISK FILE 'FILE ddname A1' ASSUMED FOR DDNAME 'ddname' NAftEFIND DMSNAM002E DMSNAM003E DMSNAM029E DMSNAM104S DMSNAM156E DMSNAM618E DMSNAM621E DMSNAM622E DMSNAM622W DMSNAM633E DMSNAM633W DMSNAM634E DftSNAft6351 DMSNAM637E FILE 'fn ft fm' NeT FOUND INVALID OPTION 'option' INVALID PARAMETER 'parm' IN THE OPTION 'option' FIELD ERROR Inn' REAtING FILE 'fn ft fm' FRO DISK RECORD NOT FCUND - FILE 'fn ft fm' HAS ONLY 'nnn' RECORDS NUCEXT FAILED BAD PLIST: NAMEFIND MUST BE INVOKED AS A NUCLEUS EXTENSION INSUFFICIENT FREE STORAGE PCB NAMEFIND INSUFFICIENT FREE STORAGE FOR NAMEFIND BUFFER, PROCESSING CONTINUES TOO MANY TAGS iEBE ENCOUNTERED. MAXIMUM IS 64 PER LINE RETURNED VALUES WERE TRUNCATED NO VALUE TO SEARCH FOR WAS SPECIFIED NO ENTRIES WERE FOUND THAT MATCHED YOUR SEARCH CRITERIA MISSING VALUE FOE THE 'option' OPTION NAMBS DMSWNM649E DMSWNM656E DMSWNM657E DMSWNM658W DMSWNM660E DMSWNM660W DMSWNM662E DMSWNM645W DMSWNM664E EXTRANEOUS PARAMETER 'value' ERROR SEARCHING YOUR NAMES FILE, RC = XX FROM NAMEFIND COMMAND UNDEFINED FFKEY THE VALUE FOR THB 'tag' TAG IS TOO LONG TO DISPLAY IN THE PANEL THE NICKNAME FIElD MUST EE FILLED IN WARNING: THIS ENTRY DUPLICATES AN EXISTING NICKNAME YOU ARE NOT ON AN ENTRY. PRESS PF 5, 7 OR 8 TO MOVE TO AN ENTRY THE USER TAG NAME 'tagname' IS TOO LONG TO DISPLAY IN THE PANEL (ENTRYINEXT ENTRYIFREVIOUS ENTRY) NOT FOUND NOTE DMSWNT003E DMSWNT006E DMSWNT062E DMSWNT637E DMSWNT647E DMSWNT651E DMSWNT665E DMSWNT666E DMSWNT667E DMSWNT668E DMSWNT669E DMSWNT670E INVALID OPTION 'option' NO READ/WRITE DISK ACCESSED INVALID CHARACTER 'character' IN FILEID 'fn ft' MISSING (VALUEI'value') FOR THE ('option' OPTIONI'operand'IOPERAND) USERID NOT SPECIFIED FOE 'nickname' IN 'USERID NAMES' FILE ('CANCEL'I'ADD') MUST BE ISSUED FRCM NOTE FILE 'USERID NOTE *' NOT FCUND. TO BEGIN A NEW NOTE ENTBR "NOTE name" NOTE ALREADY EXISTS. ENTER 'NOTE' TO CONTINUE OR SPECIFY 'REPLACE' NOTE HEADER DOES NOT CONTAIN THE {KEYWORD 'FROM'IKEYWORD 'TO:'I'OPTIONS'I'DATE' LINE} THE 'ADD' OPTICN eUST EE SFECIFIED ALONE LIST OF ADDRESSES CANNOT BEGIN WITH ICC:' NO NAMES TO BE ADDED WERE FCUND NUCXDROP DMSNXD050E DMSNXD070E DMSNXD616W DMSNXD617E DMSNXD624W PARAMETER MISSING AFTER NUCXDROP INVALID ARGUMENT 'argument' 'name' DOES NOT EXIST ERROR CODE n FROM DMSFRET WHILE UNLOADING 'module name' MODULE NO NUCLEUS EXTENSICNS ARE LCADED Appendix A. Command-to-Message cross Reference 261 DKS NUCXLOAD DMSNXL001E DMSNXL070E DMSNXL104S DMSNXL589E DMSNXL618E DMSNXL619E DMSNXL622E NO FILENAME SPECIFIED INVALID ARGUMENT 'argument' ERROR 'nn' READING FILE 'fn ft fm' FROM DISK MISSING FILEDEF FOR DDNAME ddname NUCEXT FAILED MODULE 'module name' NCT FeUND INSUFFICIENT FREE STORAGE NUCXMAP DMSNXM070E INVALID PARAME!ER 'parameter' DMSNXM622E INSUFFICIENT FREE STORAGE Inn ENTRIES} DMSNXM6241 NO NUCLEUS EXTENSIONS ARE LOADED OPTION DMSOPT070E INVALID PARAME!EB 'parameter' DMSOPT099E CMS/DOS ENVIRONMENT NOT ACTIVE PEEK DMSWPK003E DMSWPK029E DMSWPK132S DMSWPK156E DMSWPK630S DMSWPK637E DMSWPK643E DMSWPK644E DMSWPK649E DMSWPK650E DMSWPK655E DMSWPK672E DMSWPK674E DMSWPK683E DMSWPK684E DMSWPK685E DMSWPK686E DMSSTT062E INVALID OPTION 'option' INVALID PARAME!ER 'parm' IN !HE OPTION 'option' FIELD FILE IS TOe lARGE FROM 'nnn' NOT FOUND - THE FILE HAS ONLY 'nnn' RECORDS ERROR ACCESSING SfCCL FILE MISSING VALUE FOR THE {PROFILEIFRCMIFOR} OPTION NO CLASS 'class' FlIES IN YCUR READER ALL READER FILES ARE IN HOLD STATUS OR NOT CLASS 'class' EXTRANEOUS PARAMETER 'value' INVALID SPOOLID 'nnnn' SPOOLID 'nnnn' DCES NOT EXIST VIRTUAL READER INVALID CR NO! DEFINED READER IS NeT READY THE ENTIRE FILE MUST BE PEEKED AT TO BE REFORMATTED FILE CONTAINS INVALID RECORDS AND CANNOT EE REFORMATTED THE FILE IS TOO LARGE TO BE REFORMATTED THE FILE HAS AN IRECL GREATER THAN 255 AND CANNOT BE REFORMATTED INVALID CHARAC!ER 'character' IN FILEID 'fn ft fm' PRELOAD DMSPRE001E DMSPRE002E DMSPRE109S DMSPRE183E DMSPRE234E DMSPRE235E DMSPRE236E DMSPRE237E DMSPRE238E NO FILENAME SPECIFIED FILE 'fn ft fm' NCT FOUND VIRTUAL STORAGE CAPACI!Y EXCEEDED INVALID CONTROL FILE CCNTRCI CARD ERROR IN LOAD LIST FILE 'fn ft fm' [NO INPUT] ERROR 'n' IN INPUT TEXT FILE 'fn ft [fm]' UNRESOLVED EXTERNAL REFERENCE{S} ENCOUNTERED DUPLICATE EXTERNAL SYMBOl{S} ENCOUNTERED PRELOADER PROCESSING ERROR PRINT DMSPRT002E DMSPRT003E DMSPRT008E DMSPRT013E DMSPRT029E DMSPRT033E DMSPRT039E DMSPRT044E DMSPRT048E DMSPRT054E DMSPRT062E DMSPRT069E DMSPRT070E DMSPRT104S DMSPRT123S FILE 'fn ft fm' NCT FOUND INVALID OPTION 'cption' DEVICE 'cuu' {INVALID CR NONEXISTENTIUNSUPPORTED DEVICE TYPE} MEMBER 'name' NOT FOUND IN LIBRARY INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD FILE 'fn ft fm' IS NOT A LIBRARY NO ENTRIES IN IIERARY 'fn ft fm' RECORD LENGTH EXCEEDS ALLOWABLE MAXIMUM INVALID MODE 'mode' INCOKPLETE FILEIn SPECIFIED INVALID * IN FILEln DISK 'mode' NOT ACCESSED INVALID PARAMETER -parameter' ERROR 'nn' READING FILE 'fn it fm' FROM DISK ERROR 'nn' PRINTING FILE 'fn ft fm' PSERV DMSPRV003E DMSPRV004E DMSPRV006E DMSPRV037E DMSPRV070E DMSPRV097E INVALID OPTION 'option' PROCEDURE 'procedure' NOT FOUND NO READ/WRITE 'A' DISK ACCESSED DISK 'A' IS READ/ONLY INVALID PARAMETER 'parameter' NO 'SYSRES' VOLUME ACTIVE 262 IBM VM/SP System Messages and Codes D!S DMSPRV098E DMSPRV099E DMSPRV105S DMSPRV113S DMSPRV411S NO PROCEDURE NAME SPECIFIED CMS/DOS ENVIRONMENT NOT ACTIVE ERROR Inn' WRITING FILE 'fn ft fm' TO DISK DISK {cuu} NOT ATTACHEt INPUT ERROR CODE Inn' ON 'SISRES' PUNCH D!SPUN002E D!SPUN003E D!SPUN008E DMSPUN013E D!SPUN033E DMSPUN039E DMSPUN044E D!SPUN054E D!SPUN062E D!SPUN069E D!SPUN104S D!SPUN118S DMSPUN125S FILE 'fn' NOT FOUND INVALID OPTION 'option' DEVICE 'cuu' {INVALID OR NONEXISTENTIUNSUPPORTED DEVICE TYPE} !E~BER 'name' NOT FCUNt IN LIERAR! FILE 'fn ft fm' IS NOT A LIBRARY NO ENTRIES IN IIEBAEY 'fn ft fm' RECORD LENGTH EXCEEDS ALLOWABLE !AXI!UM INCOMPLETE FILElt SFECIFIEt INVALID * IN FILEID DISK 'mode' NOT ACCESSED ERROR Inn' READING FILE 'fn ft fm' FRO! DISK ERROR PUNCHING FILE 'fn ft fm' ERROR Inn' PUNCHING FILE 'fn ft fm' QUERY DMSQRY005E DMSQRY014E DMSQRY026E DMSQRY041E DMSQRY010E DMSQRY099E DMSQRY324E NO 'option' SPECIFIED INVALID FUNCTION 'function' INVALID PARAMETER 'parameter' FOR 'function' FUNCTION NO FUNCTION SPECIFIED INVALID PARAMETER 'parameter' CMS/DOS ENVIRONMENT NOT ACTIVE NO USER DEFINED {DLBLIFILEDEFILABELDBF}'S IN EFFECT RDR DMSRDR010E INVALID PARAMETER 'parmi DMSRDR630S ERROR ACCESSING SFCCL FILE RDRLIST D!SWRL003E D!SWRL205E D!SWRL631E DMSWRL649E DMSWRL651E DMSSTT062E INVALID OPTION 'option' NO FILES IN YOUR READER MISSING VALUE FOR THE 'PBOIIIE' OPTION EXTRANEOUS PARAMETER 'parameter' 'APPEND' MUST BE ISSUEt FRCM BDRLIST OR FILELIST INVALID CHARACTER 'char' IN FILEID 'fn ft' READCARD DMSRDC008E DMSRDC031E tMSRDC042E D!SRDC054E DMSRDC062E DMSRDC105S DMSRDC124S D!SRDC205W DMSRDC1011 D!SRDC1021 DMSRDC1021 D!SRDC1381 DEVICE 'ccu' {INVALID CR NONEXISTENTIUNSUPPORTED DEVICE TYPE} DISK 'mode' IS REAt/ONII NO FILEID SPECIFIED INCO!PLETE lILlIE SFECIFIED INVALID * IN IILEID ERROR Inn' WRITING FILE 'fn ft fm' ON DISK ERROR Inn' READING CARD FILE READER EMPTY CR NCTREAD! NULL FILE READ CONTROL CARD IS MISSING. FOLLOWING ASSUMED: :READ {fn ft fmlREADCABD C!SUT1 A1} RECORD LENGTH IS 'nnn' BYTES RECEIVE DMSWRC003E DMSWRC006E DMSWRC024E DMSWRC031E DMSWRC062E D!SWRC069E DMSWRC630S DMSWRC631E DMSWRC644E DMSWRC644E DMSWRC649E DMSWRC650E DMSWRC655E DMSWRC611E DMSWRC612E DMSWRC614E INVALID OPTION 'cption' NO READ/WRITE DISK ACCESSED FILE 'fn ft fm' ALREADY EXIS~S, SPECIFY 'REPLACE' OPTION DISK 'mode' NOT ACCESSED INVALID CHARACTER '.' IN FILEID 'fn ft fm' DISK 'mode' NOT ACCESSED ERROR ACCESSING SPOOL FILE MISSING VALUE FOB THE 'NCTEBCCK' CFTION NO CLASS 'class' FILES II ICUR READER ALL READER FIlES ARE IN HOLD STATUS OR NOT CLASS 'class' EXTRANEOUS PARAMETER ·value' INVALID SPOOLln 'nnn' SPOOLID 'nnnn' DOES NOT EXIST ERROR RECEIVING FILE 'fn it fm-, RC = nn FROM 'command' VIRTUAL READER INVALID OR NOT DEFINED READER IS NeT READl Appendix A. Command-to-Message cross Reference 263 DMS DMSWRC681E THIS IS AN UNNAMED PILE. SPECIPY PILENAME AND PILETYPE DMSWRC682E ERROR COPYING PILE 'fn ft' PROM 'A' DISK to 'mode' DISK DMSSTT062E INVALID CHARACTER 'character' IN PILiID 'fn ft' RELEASE DMSARE011E DMSARE028E DMSARE048E DMSARE069E DMSARE010E INVALID DEVICE AtIEESS 'ccu' NO DEVICE SPECIFIED INVALID MODE 'mode' DISK {'mode'I'ccu'} NO~ ACCESSED INVALID PARAMETEr. 'parameter' RENAME DMSRNM002E DMSRNM003E DMSRNM019E DMSRNM024E DMSRNM030E DKSRNM031E DMSRNM048E DMSRNM051E DMSRNM054E DMSRNM062E DMSRNM069E PILE[ {S}][ 'fn [ft [fm]J' J BOT POUND INVALID OPTION 'option' IDENTICAL FILEIDS PILE 'fn ft fm' ALREADY EXISTS [SPECIFY 'REPLACE'] PILE 'fn ft fm' AlREADY ACTIVE DISK 'mode' IS READ/ONLY INVALID MODE 'mode' INVALID MODE CHANGE INCOMPLETE FILEID ['fn[ft]l] SPECIFIED INVALID * IN OUTPUT FILEID DISK 'mode' NOT ACCESSED RSERV DMSRRV003E DMSRRV004E DMSRRV006E DMSRRV010E DMSRRV091E DMSRRV098E DMSRRV099E DMSRRV105S DMSRRV113S DMSRRV411S INVALID OPTION 'option' MODULE 'module' NOT FOUND NO READ/WRITE 'A' tISK ACCESSED INVALID PARAMETER 'parameter' NO 'SYSRES' VOLUME ACTIVE NO MODULE NAME SPECIFIED CMS/DOS ENVIRONMENT NOT ACTIVE ERROR 'nn' WRI~ING FILE 'fn ft fm' ON DISK DISK {cuu} NOT ATTACHEt INPUT ERROR CODE Inn' ON '{SYSRESISYSRLB}' RUN DMSRUN001E DMSRUN002E DMSRUN048E DMSRUN070E DMSRUN999E SAVENCP DMSNCP001E DMSNCP002E DMSNCP003E DMSNCP013E DMSNCP021E DMSNCP025E DMSNCP045E DMSNCP056E DKSNCP099W DMSNCP109S NO FILENAME SPECIFIED FILE ['fn [ft [fm]]'] NCT FOUND INVALID MODE 'modE' INVALID ARGUMENT 'argument' NO [ft] MODULE FOUND NO FILENAME SPECIFIED FILE 'fn ft' NOT FOUND INVALID OPTION 'cption' MEMBER 'name' NOT FOUNt IN LIBRARY 'fn ft fm' ENTRY POINT 'symtol' NOT FOUND INVALID DATA IN 370X CCNTRCl PROGRAM UNSUPPORTED CONTROL PRCGRAM TYPE FILE 'fn ft fm' CONTAINS INVJLID RECORD FORMATS GENERATION PARAMETERS INCOMPATIBLE WITH VM/370 VIRTUAL STORAGE CAPACITY EXCEEDED SENDFILE DMSWSF002E DMSWSF003E DMSWSF006E DMSWSF048E DMSWSF054E DMSWSF062E DMSWSF069E DMSWSF081E DMSWSF637E DMSWSF647E DMSWSF648E DMSWSF657E DMSWSP661E FILE 'fn ft fm' NOT POUND INVALID OPTION 'option' NO READ/WRITE DISK ACCESSED INVALID MODE 'mode' INCOMPLETE lILElt SPECIFIED INVALID CHARACTER '.' IN FILEID 'fn ft fm' DISK 'mode' NO~ ACCESSED INVALID REPLY - ANSWER "YES" OR "NO" MISSING NODEID FOR THE AT OPERAND USERID NOT SPECIFIED FOR 'nickname' IN 'USERID NAMES' FILE USERID 'name'NOT FOUND. NO PILES HAVE BEEN SENT UNDEFINED PFREY NOTE HEADER DOES NOT CONTAIN THE {KEYWORD 'PROM'IKEYWORD ''10:'1 • OPTIONS' LINE} DMSWSF611E ERROR SENDING FILE 'fn ft fm', RC = nn FROM 'command' DMSWSF672E VIRTUAL PUNCH INVAlID CR NCT DEFINED DMSWSF613E ADDRESSEES ARE IN THE NOTE HEADER CABDS~ DO NOT SPECIFY 26q IBM VM/SP System Messages and Codes DMS NAMES WITH NOTE OPTION PUNCH IS NOT BEAtl NO NAMES SPECIPIEt INVALID CHARACTER '.' FOB NETWORK ID INVALID OPTION 'option' IN CFTION LINE INVALID NOTE HEAtER FORMAT. NOTE CANNOT BE SENT (DISK 'mode' IS READ/ONLYIDISK 'mode' IS FULL). NOTE CANNOT BE SENT DMSWSF680E INVALID FILEID SPECIFIED WITH 'FILELIST' OPTION DMSSTT048E INVALID MODE 'mode' DMSSTT062E INVALID CHARACTER 'character' IN FILEID 'fn ft' DMSWSF674E DMSWSF675E DMSWSF676E DMSWSF677E DMSWSF678E DMSWSF679E SET DMSLI0002I DMSSET014E DMSSET026E DMSSET031E DMSSET047E DMSSET048E DMSSET050E DMSSET061E DMSSET070E DMSSET098W DMSSET099E DMSSET100W DMSSET142S DMSSET333E DMSSET400S DMSSET401S DMSSET410S DMSSET444E FILE IfnI TXTLIB NOT FOUND INVALID FUNCTION 'function' INVALID PARAMETER 'parameter' FOR 'function' FUNCTION LOADER TABLES CANNCT BE MC[IFIED NO FUNCTION SPECIFIED INVALID MODE 'mode' PARAMETER MISSING AFTER (DDNAMEISISxxxlfunction) NO TRANSLATICN CHARACTER SPECIFIED INVALID PARAMETER '~arameter' CMS OS SIMULATION NCT AVAI1AELE CMS/DOS ENVIRONMENT NOT ACTIVE SYSTEM NAME 'name' NOT AVAILAELE SAVED SYSTEM NAME 'name' INVALID nnnnnK PARTITICN TOC LAEGE FCR THIS VIRTUAL MACHINE SYSTEM 'sysname' "DOES NOT EXIST VM SIZE {size) CANNCT EXCEED 'DMSDOS' START ADDRESS {address) CONTROL PROGRAM EREOR INDICATION 'retcode' VOLUME LABEL IS NCT A tOS SISRES SETPRT DMSSPR002E DMSSPR014E DMSSPR026E DMSSPR113S DMSSPR145S DMSSPR196I DMSSPR197S DMSSPR198E DMSSPR199E DMSSPR204E DMSSPR352E FILE 'fn ft' NCT FCUND INVALID FUNCTION 'function' INVALID VALUE 'value' FOR 'keyword' KEYWORD PRINTER 'OOE' NOT ATTACHED INTERVENTION REQUIRED CN PRINTER PRT cuu SETUP COMPLETE UNDIAGNOSED ERROR FROM PRINTER 'OOE' SETPRT CAUSED A leAt CHECK - SNS=ssssssssss PRT 'OOE' NOT A VIRTUAL 3800 TOO MANY WCGM'S NEEDED FOR 'CHARS' INVALID SETPRT DATA IN FILE 'fn ft' SETKEI DMSSSK070E DMSSSK362E DMSSSK363E DMSSSK364E DMSSSK365E DMSSSK400S DMSSSK410S INVALID PARAMETER 'parameter' INVALID STCRAGE PRCTECT KEI 'key' INVALID STARTING AtDRESS 'startadr' VM STORAGE NOT LARGE ENOUGH TO CONTAIN SYSTEM LOADING AT startadr TO endadr SYSTEM NAME NCT SPECIFIED SYSTEM 'name' DOES NOT EXIST CONTROL PROGRAM ERROR INDICATION 'nnn' SORT DMSSRT002E DMSSRT009E DMSSRT019E DMSSRT034E DMSSRT037E DMSSRT053E DMSSRT054E DMSSRT062E DMSSRT063E DMSSRT069E DMSSRT070E DMSSRT104S DMSSRT105S DMSSRT212E DMSSRT604E FILE ['fm [ft [fm]]t] NOT FOUND COLUMN 'col' EXCEEtS RECCRt lENGTH IDENTICAL FILEIDS FILE 'fn ft fm' IS NOT FIXED LENGTH DISK 'mode' IS READ/ONLY INVALID SOET FIELD PAlE tEFINED INCOMPLETE FILEID SPECIFIED INVALID {=I*ICHAB.'char') IN FILEID ['fn ft fm'] NO LIST ENTERED DISK 'mode' NOT ACCESSED INVALID PARAMETER 'parameter' ERROR 'nn' READING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK MAXIMUM NUMEEE OF RECORDS EXCEEDED ENTER SORT FIELDS: Appendix A. Command-to-Message Cross Reference 265 DMS SSERV DMSSRV003E DMSSRV004E DMSSRV006E DMSSRV070E DMSSRV097E DMSSRV098E DMSSRV099E DMSSRV105S DMSSRV1l3S DMSSRV4llS DMSSRV194S INVALID OPTION 'o~tion' BOOK 'suhl.hook' NCT FCUND NO READ/WRITE 'A' DISK ACCESSED INVALID PARAMETER 'parameter' NO 'SYSRES' VOLUME ACTIVE NO BOOK NAME SPECIFIED Cl!S/DOS ENVIRONMEN~ NOi ACTIVE ERROR Inn' WRITING FILE 'fn ft fm' ON DISK DISK (cuu) NOT ATTACHED INPUT ERROR CODE 'nnw CN • (SlSRESISlSSLB), BOOK 'suhl.took' CONTAINS BAD RECORDS START DMSLI0021E ENTRl POINT 'name' NOT FCUND DMSLI0055E NO ENTRY PO IN! DEFINED DMSLI07401 EXECUTION BEGINS ••• S~ATE/STATEW DMSSTT002E DMSSTT048E DMSSTT054E DMSSTT062E DMSSTT069E DMSSTT070E DMSSTT227I DMSSTT2281 DMSSTT229E Ifn ft fm' NCT FCUND INVALID MODE 'mode' INCOMPLETE FILElr SPECIFIED INVALID * IN ~ILEID 'fn ft' DISK 'mode' NCT ACCESSED INVALID PARAMETER '~arameter' PROCESSING VCIUME 'no' IN DATA SET 'data set name' USER LABELS BYPASSED ON DATA SET 'data set name' UNSUPPORTED OS rATA SET, ERRCR 'code' SVCTRACE DMSOVR014E DMSOVR047E DMSOVR104S DMSOVR109S INVALID FUNCTION 'function' NO FUNCTION SPECIFIED ERROR 'nn' READING FILE 'DMSOVR MOtULE' ON DISK VIRTUAL STORAGE CAPACI~Y EXCEEDED SYNONYM DMSSYN002E DMSSYN003E DRSSYN007E DMSSYN032E DMSSYN056E DMSSYN066E DMSSYN104S DMSSYN7111 DMSSYN712I FILE 'fn ft fm' NOT FOUND INVALID OPTION 'option' FILE 'fn ft fm' NOT FIXED, 80 CHAR. RECORDS INVALID FILETYPE 'ft' FILE 'fn ft fm' CONTAINS INVALID RECORD FORMATS 'STD' and 'NOSTD' ARE CONFlICTING CPTIONS ERROR Inn' REAtING FILE 'fn ft fm' FROR DISK NO SYSTEM SYNONYMS IN EFFECT NO SYNONYMS (DMSINA NOT IN NUCLEUS) TAPE DMSTPE002E DMSTPE003E DMSTPE010E DMSTPE014E DMSTPE017E DMSTPE023E DMSTPE027E DMS~PE029E DMSTPE037E DMSTPE042E DMSTPE043E DMSTPE047E DMSTPE048E DMSTPE057E DMSTPE058E DMSTPE070E DMS~PE096E DMSTPE104S DMSTPE105S DMSTPE1l0S DMSTPE111S DMSTPE113S DMSTPE115S DMSTPE431E DMSTPE7011 266 FILE[ (S)]['fn eft [fm]]') NOT FOUND INVALID OPTION 'option' PREMATURE EOF ON FILE ['fn ft [fm]'] INVALID FUNCTION 'function' INVALID DEVICE ADDRESS 'cuu' NO FILETYPE SpECIFIED INVALID DEVICE 'device name' INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD DISK 'mode' IS READ/ONLY NO FILEID[ {S}] SPECIFIED 'TAPn {CUU} , IS FILE PROTECTED NO FUNCTION SPECIFIED INVALID MODE 'mode' INVALID RECORD FCR~AT END-OF-FILE OR END-OF-TAPE INVALID PAEAMETEE 'parameter' FILE 'fn ft' DATA BLOCK COUNT INCORRECT ERROR 'nn' READING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK ERROR READING 'TAPn {cuu}' EREOR WRITING 'TAPn {cuu} , TAPn{cuu} NOT ATTACHED {CONVERSION I {119)-TRACKI{80016250} BPIITRANSLATIONIDUAL DENSITY} FEATURE NOT SUPPOR~ED ON DEVICE 'cuu' 'TAPn {CUU} , VOLl LABEL MISSING NULL FILE IBM VM/SP system Messages and Codes DftS TAPEMAC DMSTMA001E DMSTMA003E DMSTMA057E DMSTMA070E DMSTMA105S DMSTMA109S DMSTMA110S DMSTMA137S DMSTMA138S DMSTMA139S DMSTMA420E NO FILENAME SPECIFIED INVALID OPTION 'cFtion' INVALID RECORD FCEMAT INVALID PARAMETER 'Farameter' ERROR 'nne WRITING FILE 'fn ft' ON DISK VIRTUAL STORAGE CAPACITY EXCEEDED ERROR READING 'TAFn' ERROR nn ON 'S~ATE' FOR fn ft ERROR nn ERASING fn ft BEFCRE LOAtING TAPE TAPE FILE EXCEEDS 9 CMS MACLIBS NSL EXIT FILENAME MISSING CR INVALID TAPPDS DMSTPD003E DMSTPD058E DMSTPD105S DMSTPD109S DMSTPD110S DMSTPD420E DMSTPD7031 DMSTPD7071 INVALID OPTION 'option' END-OF-FILE OR END-OF-TAPE ERROR Inn' iRITING FILE 'fn ft fm' VIRTUAL STORAGE CAPACITY EXCEEDED ERROR READING 'TAFn' NSL EXIT FILENAME MISSING OR INVALID FILE 'fn ft [fm]' COPIEt TEN FILES COPIED TELL DMSWTL637E DMSWTL647E DMSWTL648E DMSWTL676E MISSING NODEID FOR THE AT OPERAND USERID NOT SPECIFIED FOR 'nickname' IN 'USERID NAMES' FILE USERID 'name' NOT FOUND. NO MESSAGE HAS BEEN SENT INVALID CHABACTER FOR NETWORK ID TXT LIB DMSLBT001E DMSLBT002E DP.lSLBT002W DMSLBT003E DMSLBT013E DMSLBT014E DMSLBT037E DftSLBT046E DMSLBT047E DMSLBT056E DMSLBT056W DMSLBT069E DMSLBT104S DMSLBT105S DMSLBT106S DMSLBT213W NO FILENAME SPECIFIED FILE[ {S}] [' fn [ft [fm]]'] NCT FOUND FILE[ {S} ]( 'fn [ft [fm]]'] NOT FOUND INVALID OPTION 'oFtion' MEMBER 'name' NOT FCUND IN lIBRARY 'fn ft fm' INVALID FUNCTION 'function' DISK 'mode' IS REAt/ONIY NO LIBRARY NAME SPECIFIED NO FUNCTION SPECIFIED FILE 'fn ft fm' CONTAINS INVALID [NAMEIALIASIENTRYIESD] RECORD FORMATS FILE 'fn ft fm' CONTAINS [{NAMEIALIASIENTRYIESD}] INVALID RECORD FORMATS DISK 'mode' NOT ACCESSED ERROR Inn' READING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK NUMBER OF MEMBER NAMES EXCEEDS MAX 'nnnn'. FILE 'fn ft fm' NOT ADDED LIBRARY 'fn ft fm' NCT CREATED TYPE DMSTYP002E DP.lSTYP003E DMSTYP005E DMSTYP009E DMSTYP013E DMSTYP029E DMSTYP033E DMSTYP039E DMSTYP049E DMSTYP054E DMSTYP062E DMSTYP069E DMSTYP104S FILE 'fn ft fm' NCT FOUND INVALID OPTION 'oFtion' NO 'option' SPECIFIED COLUMN 'col' EXCEEDS RECORD LENGTH MEMBER 'name' NOT PCDND IN LIERARY INVALID PARAMETER 'parameter' [IN THE OPTION 'option' FIELD] FILE 'fn ft fm' IS NOT A IIERARY NO ENTRIES IN LIERARY 'fn ft fm' INVALID LINE NUMEER 'line number' INCOMPLETE FILElt SPECIFIED INVALID IN FILEID DISK MODE NOT ACCESSED ERROR 'nne READING FILE 'fn ft fm' FROM DISK UPDATE DMSUPD001E DMSUPD002E DMSUPD003E DMSUPD007E DMSUPD010W DMSUPD024E DMSUPD037E DMSUPD048E DMSUPD065E DMSUPD066E NO FILENAME SPECIFIED FILE 'fn ft fm' NOT FOUND INVALID OPTION 'oFtion' FILE 'fn ft fm' IS NOT FIXED, 80 CHAR. RECORDS PREMATURE EOF CN FILE 'fn ft fm' FILE 'UPDATE CMSUT1 fm' ALREADY EXISTS DISK 'A' IS READ/CNLY INVALID MODE 'mode' 'option' OPTION SPECIFIED TWICE 'option' AND 'option' ARE CONFLICTING OPTIONS '*' * Appendix A. Command-to-Message Cross Reference 267 DMS DMSUPD069E DISK 'A' NO~ ACCESSED DMSUPD070E INVALID PARAMETER 'parameter' D~SUPD104S ERROR 'nn' READING FILE 'fn ft fm' FROM DISK DMSUPD105S ERROR 'nn' WRITING FILE 'fn ft fm' ON DISK DMSUPD174W SEQUENCE ERROR IN!RCDUCED IN OUTPUT FILE: •••••••••• TO •••••••••• DMSUPD176W SEQUENCING OVERFLOW FOLLCWING SEQ NUMBER' ••••••••• • DMSUPD1771 WARNING MESSAGES ISSUEE {SEVERITY = nn}. ['REP' OPTION IGNORED] DMSUPD1781 UPDATING ['fn ft fm'] iITH 'fn ft fm' DMSUPD179E MISSING OR DUPLICATE 'MACS' CARD IN CONTROL FILE 'fn ft fm' DMSUPD180W MISSING PTF FILE 'fn ft fm' DMSUPD181E NO UPDATE FILES WERE FCUND DMSUPD182W SEQUENCE INCREMEN~ IS ZERO DMSUPD183E INVALID {CONTROLIAUX} FILE CeNTROL CARD DMSUPD184W ' . / S' NOT FIRST CARD IN UPDATE FILE--IGNORED DMSUPD185W INVALID CHAR IN SECUENCE FIELD •••••••••• DMSUPD186W SEQUENCE NUMBER •••••••••• NC! FOUND DMSUPD187E OPTION 'STK' INVALID WITHOUT 'CTL' DMSUPD207W INVALID UPDATE FILE CONTROL CARD DMSUPD210W INPUT FILE SEQUENCE ERROR ••••••••••• TO •••••••••• , DMSUPD299E INSUFFICIEN! STORAGE TO COMPLETE UPDATE DMSUPD300E INSUFFICIENT STORAGE TC EEGIN UPDATE DMSUPD3041 UPDATE PROCESSING WILL BE DONE USING DISK XEDIT o~erand DMSALT520E INVALID OPERAND DMSALT545E MISSING OPERAND (S) DMSCAN520E INVALID OPERAND : DMSJOI503E DMSJOI561E DMSJOI562E DMSJOI564W DMSJOI575E DMSJOI585E c~erand TRUNCATED CURSOR IS NOT ON A VALID DATA FIELD OPTION 'CURSOR' VAlID IN DISPLAY MODE ONLY EOF REACHED INVALID JOIN CCLUMNS DEFINED NO LINE (S) CHANGED DMSMOD520E INVALID OPERAND : operand DMSMOD529E SUBCOMMAND IS ONLY VALID IN DISPLAY MODE DMSMOD545E MISSING OPERAND(S) DMSPOW117S ERROR WRITING TO DISPLAY TERMINAL DMSPOW529E SUBCOMMAND IS CNLY VALID IN DISPLAY MODE DMSPQU520E INVALID OPERAND : operand DMSPQU5531 EDITING FILE: fn ft fm DMSPQU577E FILE HAS BEEN CHANGED. USE QQUIT !O QUIT ANYWAY DMSSCH520E DMSSCH525E DMSSCH529E DMSSCH545E DMSSCH5511 DMSSCH561E DMSSCH569E DMSSCH574E DMSSCH574E DMSSCH586E INVALID OPERAND : operand INVALID PFKEY NUMBER SUBCOMMAND IS CNLY VALID IN EISPLAY MODE MISSING OPERAND(S) STRING 'string' FCUND --- PFnn SET FOR SELECTIVE CHANGE. CURSOR IS NOT ON A VALID DA~A FIELD NO 'CHANGE' OR 'CLOCATE' SUECOMMAND SPECIFIED CHANGE NOT VALID AF~ER CURSOR MOVEMENT CHANGE NOT VALID WITH CLOCATE NOT FOUND {ON SCREEEN} DMSSOR520E INVALID OPERAND : operand DMSSPL561E DMSSPL562E DMSSPL575E DMSSPL585E DMSSPL586E CURSOR IS NOT ON A VALID DATA FIELD OPTION 'CURSOR' VALID IN DISPLAY MODE ONLY INVALID SPLIT COLUMNS DEFINED NO LINE(S) CHANGED NOT FOUND DMSSTA024E FILE 'fn XEDIT A' ALREADY EXISTS DMSSTA520E INVALID OPERAND : operand DMSSTA7031 FILE 'fn XED IT A1' CREATED DMSXBG109S VIRTUAL STORAGE STORAGE EXCEEDED DMSXCG5011 nn LINES DELETED DMSXCG502W NO LINE TO RECOVER 268 IBM VM/SP System Messages and Codes D~S DMSXCG503E DMSXCG504E DMSXCG505E DMSXCG506I DMSXCG5061 DMSXCG509W DMSXCG511E DMSXCG5171 DMSXCG518E DMSXCG520E DMSXCG5221 TRUNCATED nn LINE(S} TRUNCATEt NOT EXECUTED: iHE iARGET LINE (nn) IS WITHIN THE LINES TO MOVE n LINES MOVED n LINES COPIED USE GET AND/OR PUT (D) TO MCVE LINES IN UPDATE MODE STRING2 CONTAINS MORE ABBliRARY CHARACTERS THAN STRING1 nn OCCURRENCE(S) CHANGED ON nn LINE(S) nn OCCURRENCE(S) CHANGED CN nn LINE(S); nn LINE(S) TRUNCATED INVALID OPERANt : oFerand nn OCCURRENCES DMSXCM5121 INVALID SUBSET COMMAND DMSXCM5131 UNKNOWN CP/CMS COMMAND DMSXCM514E RETURN CODE Inn' FECM 'command' DMSXCT002E DMSXCT037E DMSXCT104S DMSXCT105S DMSXCT520E DMSXCT521E DMSXCT5231 DMSXCT526E DMSXCT527E DMSXCT529E DMSXCT531E DMSXCT532E DMSXCT534E DMSXCT535E DMSXCT536E DMSXCT537E DMSXCT539E DMSXCT540E DMSXCT541E DMSXCT545E DMSXCT554S FILE 'fn ft fm' NOi FOUND DISK 'mode' IS READ ONLY ERROR Inn' READING FILE 'fD ft fm' FRO~ DISK ERROR Inn' WRITING FILE 'fD ft fm' ON DISK INVALID OPERANt : oFerand INVALID LINE NU~EEE TYPEWRITER MODE OPTION 'option' VALID IN DIS~IAY MCDE ONLY INVALID COLUMN NUMEER SUBCOMMAND IS CNLY VALID IN tIS PLAY MODE DISK IS FULL. SET N~W FILEMODE OR CLEAR SCME DISK SPACE DISK IS FUll. AUTCSAVE FAILED TOO MANY LOGICAL SCREENS DEFINED INVALID PARMS FOR BENUM NUMBER OF LINES EICEEDS PHYSICAL SCREEN SIZE EACH LOGICAL SCREEN MUST CONTAIN AT LEAST 5 LINES NAMED LINE NOT FOUND NAME ALREADY DEFINED ON lINE 'nnw INVALID NAME MISSING OPERAND(S) NO STORAGE AVAILABLE DMSXDC512E DMSXDC520E DMSXDC542E DMSXDC543E DMSXDC544E DMSXDC545E DMSIDC546E DMSXDC547E DMSXDC548E DMSXDC549E DMSXDC550E DMSXDC554S INVALID SUBSET COMMAND INVALID OPERAND : oFerand NO SUCH SUBCOMMANt : name INVALID NUMEER : XXIXXXXX INVALID HEI DATA : xxxxxxxx MISSING OPERAND(S) TARGET NOT FOUND SYNONYM DEF1NITION INCOMPLETE INVALID SYNCNYM CPERANt : operand SYNONYM ABEREVIATION TOO LARGE TOO MANY OPERANDS IN SYNONYM DEFINITION NO STORAGE AVAILABLE DMSXDS589E MISSING FILEDEF FCB DDNAME SYSIN DMSXDS590E DATA SET TOO LARGE DMSXDS591E OPEN ERROR ON SYSIN DMSXED553I EDITING FILE: fn ft fm DMSXED554S NO STORAGE AVAILABLE DMSXED555E FILE 'fn ft fm' ALREADY IN STORAGE DMSXER556S UNDEFINED MESSAGE (CMSIER CAllED AT hex loc) DMSXFC557S NO MORE STORAGE TO INSERT lINES DMSXFD554S NO STORAGE AVAILAELE DMSXFD559W WARNING FILE IS EM~TY DMSXFD560W NOT ENOUGH SPACE FOR SERIALIZATION BETWEEN TRUNC AND LRECL DMSXGT002E DMSXGT104S DMSXGT156E DMSXGT521E DMSXGT562E DMSXGT563W FILE 'fn ft fm' net found ERROR Inn' READING FILE 'fD ft fm' FROM DISK 'RECORD nn' NOT FOUND - FILE 'fn ft fm' HAS ONLY 'nn' RECORDS INVALID LINE NUMEER NO LINE(S) SAVED EY PUT (D) SUBCOMMAND RECORDS TRUNCATED Appendix A. Command-to-Message Cross Reference 269 DMS DMSXGT564W EOF REACHED DMSXGT565W EOF REACHED; RECORDS TRUNCATED DMSXIN002E DMSXIN003E DMSXIN024E DMSXIN029E DMSXIN054E DMSXIN065E DMSXIN066E DMSXIN070E DMSXIN104S DMSXIN132S DMSXIN500E DMSXIN554S DMSXIN5711 FILE 'fn ft fm' NCT FOUND INVALID OPTION 'option' FILE 'XEDTE!P CMSUT1 A1' ALREADY EXISTS INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD INCOMPLETE FIlEIE SPECIFIED 'option' OPTION SPECIFIED TWICE 'option' AND 'option' ARE CCNFLICTING OPTIONS INVALID PARAMETEB 'parameter' ERROR 'nn' READING FILE 'fn ft fm' FROM DISK FILE 'fn ft fm' Tce LAEGE UNABLE TO UNPACK FILE 'fn ft fm' NO STORAGE AVAILABLE CREATING NEW FILE DMSXI0572E TERMINAL ERROR FORCED CASE UPPERCASE DMSXMA104S ERROR Inn' READING FILE 'fn ft fm' FROM DISK DMSXMC009E DMSXMC545E DMSXMC575E DMSXMC576E COLUMN Inn' EXCEEDS RECORD lENGTH (nn).RC=5 MISSING OPERAND(S) INVALID VERIFY COLUMNS DEFINED TOTAL VERIFY WIDTH EXCEEDS SCREEN SIZE (nn) DMSXMD503E DMSXMD5101 DMSXMD529E DMSXMD5731 DMSXMD5871 TRUNCATED AUTOSAVED AS 'fn ft fm' SUBCOMMAND IS ONLY VALID IN DISPLAY MODE INPUT MODE: XEDIT: DMSXML529E SUBCOMMAND IS CNIY VALID IN DISPLAY MODE DMSXMS009E DMSXMS053E DMSXMS063E DMSXMS554S DMSXMS596S COLUMN Inn' EXCEEDS RECORD LENGTH (nn).RC=5 INVALID SORT FIELD PAIB DEFINED NO SORT LIST GIVEN NO STORAGE AVAIIAEIE THIS MODULE MUST EE CALLED WITHIN THE EDITOR DMSXP0596S THIS MODULE MUST EE CALLED WITHIN THE EDITOR DHSXPT037E DMSXPT105S DMSXPT554S DMSXPT5711 DMSXPT579R DMSXPT580W DISK 'mode' IS REAt ONLY ERROR Inn' WRITING FILE 'fn ft fm' ON DISK NO STORAGE AVAILABLE CREATING NEW FILE RECORDS WILL BE TRUNCATED TO nn CONTINUE (YES/NO)?: PUT NOT EXECUTED DMSXSC117S ERROR WRITING TO DISPLAY TERMINAL DMSXSC5101 AUTOSAVED AS 'fn ft fm' 270 DMSXSE009E DMSXSE037E DMSXSE048E DMSXSE515E DMSXSE519E DMSXSE520E DMSXSE521E DMSXSE524W DMSXSE525E DMSXSE526E DMSXSE528E DMSXSE530I COLUMN 'nn' EXCEEDS RECORD LENGTH (nn) .RC=5 DISK 'mode' IS REAE ONLY INVALID MODE "mode' RECFM MUST BE FIVIFPIVP LRECL MUST BE LOWER THAN WIDTH (nn) INVALID OPERAND : operand INVALID LINE NUMEER NONDISP CHARACTER RESET TO BLANK INVALID PFKEY NUMEER OPTION 'option' VALID IN DISPLAY MCDE ONLY INVALID RANGE : TARGET2 (lINE nn) PRECEDES TARGET1 (LINE nn) nn FILE(S) IN STORAGE DMSXSE538E DMSXSE545E DMSXSE548E DMSXSE552E DMSXSE554S DMSXSE558W DMSXSE560W DMSXSE575E NO NAME DEFINED MISSING OPERAND(S) INVALID SYNONYM OPERAND : operand NO SYNONYM CURRENTLY DEFINED NO STORAGE AVAILABLE WRONG FILE FCRMAT FOR SERIALIZATION NOT ENOUGH SPACE FOR SERIALIZATION BETWEEN TRUNC AND LRECL INVALID TABS CCLUMNS DEFINED IBM VM/SP System Messages and Codes DKS DKSXSE575E INVALID ZONE CCLUENS DEFINED DKSXSl581l /SOS FACILITY NOT AVAILABLE DKSXSS561E CURSOR IS NOT CN A VALID DATA FIELD DKSXSUOQ8E DMSXSU062E DKSXSU069E DKSXSU137S DMSXSU229E DMSXSU5101 DKSXSU559W DMSXSU582S DMSXSU5831 DKSXSU58QI DMSXSU585E DKSXSU586E DKSXSU5871 DMSXSU588E INVALID KODE 'mode' INVALID CHARACTER IN FILEIE 'fn ft fm' DISK 'mode' NOT ACCESSED ERROR Inn' ON STATE FOR 'fn ft fm' UNSUPPORTED OS tATA SET AUTOSAVED AS 'fn ft fm' WARNING FILE IS EMPTY EDITOR ABEND EOF: TOF: NO LINES(S) CHANGEt. NOT FOUND XEDIT: PREFIX SUBCOKMANt WAITING ••• DMSXUP002E DMSXUP007E DMSXUP174W DMSXUP1781 DMSXUP179E DMSXUP180W DMSXUP183E DMSXUP184W DMSXUP185W DMSXUP186W DKSXUP207W DMSXUP210W DMSXUP597E DMSXUP598S DMSXUP599S FILE 'fn ft fm' NCT FOUND FILE 'fn ft fm' IS NOT FIXED, 80 CHAR RECORDS SEQUENCE EEROR INTRCDUCED IN OUTPUT FILE: ' ••••••••• TO ••••••••• UPDATING WITH 'fn ft fm' MISSING OR DUPLICATE 'KACS' CARD IN CONTROL FILE 'fn ft fm' MISSING PTF FILE 'fn ft fm' INVALID AUX FILE CONTROL CARD './S' NOT FIRST CARt IN UPtATE FILE -- IGNORED NON NUMERIC CHARACTER IN SEQUENCE FIELD , •••••••• SEQUENCE NUMBER NCT FOUND: INVALID UPDATE FILE CONTROL CARD INPUT FILE SEQUENCE ERROR , •••••••• , TO ••••••••• UNABLE TO MEEGE UPDATES CONTAINING ·.S· CARDS UNABLE TO BUILD UPDATE FILE INTERNAL LIST OESTROYED UNABLE TO BUILD UPDATE FILE : SERIALIZATION DESTROYED DMSZAP001E DMSZAP002E DMSZAP002W DMSZAP003E DMSZAP007E DMSZAP014E DMSZAP047E DMSZAP056E DMSZAP070E DMSZAP104S DMSZAP190W DMSZAP191W DMSZAP192W DMSZAP193W DMSZAP194W NO FILENAME SPECIFIED FILE 'fn ft· NOT FCUND FILE 'fn ft· NCT FCUND INVALID OPTION 'oFtion' FILE 'fn ft' IS NCT FIXED, 80 CHAR. RECORDS INVALID FUNCTION 'function' NO FUNCTION SPECIFIED FILE 'fn ft' CONTAINS INVALID RECORD FORMATS INVALID PARAMETER 'parameter' ERROR 'nn' READING FILE 'fn ft' FRCM DISK INVALID CONTROL RECORD OE NC GO SWITCH SET PATCH OVERLAPS-SET NO GO SWITCH ERROR-ODD NUMBER CF DIGITS-SET NO GO SWITCH PRECEDING CONTROL RECORD FLUSHED CSECT NOT FOUND IN {MEMBER 'membername'IMODULE 'modulename'} SET NO GO SWI'leH BASE VALUE INVALlt-SET NO GO SWITCH VERIFY REJECT-SET NO GO SWITCH FILE 'fn ft· IS NOT VARIAELE RECORD FORMAT FILE 'fn ft' IS ON A READ/ONLY DISK ERROR 'nnn' CN PEINTER NO LOADER TAELE PRESENT FOR MODULE 'fn ft'-SET NO GO SWITCH MEMBER 'name' N01 PCUNt--SET NO GO SWITCH INVALID VER/REP EISP--SET Ne GO SWITCH DUMMY LOG ENTRY IN FILE Ifn ft fm' ZAP PROCESSING CCMPLETE MEMBER FOUND IN LIBRARY 'fn' ZAP DMSZAP195W DMSZAP200W DMSZAP208E DMSZAP210E DMSZAP245S DMSZAP246W DMSZAP2Q7W DMSZAP248W DMSZAP2491 DMSZAP7501 DMSZAP7511 Appendix A. Command-to-Message Cross Reference 271 D~S C~S INITIALIZATION ROUTINE DftSINS098W CftS OS SIftULATION NOT AVAILABLE D!SINS100W SHARED {SSTATIYSTAT} NOT AVAILABLE CftS/DOS CLOSE D8SCLS043E D8SCLS058E DMSCLS08BE DftSCLS089E DftSCLS113S DftSCLS140S D8KCLS4291 ROUTINE TAPn IS FILE PROTECTED END-OF-FILE OR END-OF-TAPE eN 'TAPn' UNSUPPORTED DTF TYPE 'dtftypE' CLOSE ERROR CODE Inn' ON • {fnISYSxxxITAPn}, 'TAPn (cuu) , NOT ATTACHED SEOV/FEOV MACRC NCT SUIPCRTED 'TAPn (cuu) , EeT CN OUTPUT CMS/DOS GENERATION PROCEDURE DftSGEN006E NO READ/WRITE A-DISK ACCESSED D8SGEN095E INVALID ADDRESS 'address' DMSGEN110E CORRECT FORM IS: DOSGEN LOCATION SEGNAME DMSGEN111E DOSGEN FAILED DUE TO LOAD ERRORS DMSGEN141S DOSGEN FAILED DUE TC SAVESIS ERRORS DMSGEN1151 DOSGEN COMPLETE CftS/DOS OPEN ROUTINE DMSBOP031E DISK 'mode' IS READ/ONLY DMSBOP043E TAPn IS FILE PROTECTED DMSBOP058E END-OF-FILE OR END-OF-TAPE ON 'TAPn' DMSBOP069E DISK 'mode' NCT ACCESSED DMSBOP086W DLBL 'ddname l DUMMY INVALID FOR VSAM DMSBOP088E UNSUPPORTED DTF TYPE 'dtftJpe' DftSBOP089E OPEN ERROR CODE 'nn' ON (fnISYSxxxITAPN) DMSBOP113S {TAPnlmode (cuu)} NeT A~TACHED DMSBOP302E NO SYSxxx OPERANt SPECIFIED CMS/DOS OPEN ROUTINE (continued) DMSBOP308E 'mode' DISK IN CMS FORMAT; INVALID FOR NON-CftS DATASET DMSBOP400S SYSTEM 'sysname' tOES NOT EXIST DMSBOP401S VM SIZE (size) CANNOT EXCEED 'DMSDOS' START ADDRESS (address) DMSBOP410S CONTROL PROGRAM EBBOR INDICATION 'retcode' DMSBOP413S STORAGE NOT INITIALIZED FOR VSAM PROCESSING CMS/DOS OPEN LIBRARY ROUTINE DHSOPl089E OPEN ERROR CODE Inn' ON SYSxxx DHSOPL158E NO CMS/DOS PROCEDURE LIEBARY SUPPORT eMS/DOS SVC HANDLER ROUTINE DHSDOS004E PHASE 'phase' NOT FCUND DMSDOS091E SAVEABEA ADDRESS IN PARTITION PIB NOT EQUIVALENT TO LTA SAVEAREA ADDRESS DHSDOS092E STXIT SAVEAREA ADDEESS INVALID DMSDOS093E MVCOM MACRO ATTEMPTING TO ALTER OTHER THAN POSITION 12-23 OF COHREG DMSDOS094E FROH ADDRESS ON MVCOH HACRe INVALID DMSDOS095E INVALID ADDRESS 'address' DMSDOS096S UNSUPPORTED FUNC~ICN IN A LICeS ROUTINE DSMDOS121S UNSUPPORTED SiC no o (HEX no.) CALLED FROH caller DMSDOS140S {FEOVD\SEOVIFEOV} MACRO NOT SUPPORTED DMSDOS160S JOB CANCELED DUE TO PROGEA~ REQUEST DMSDOS401S VM SIZE (size) CANNOT EXCEED 'DHSDOS' START ADDRESS (address) DMSDOS413S STORAGE NOT INITIALIZED FOR VSAM FROCESSING GftSXGEN PROCEDURE DMSCMS006E NO READ/WRITE A-tISK ACCESSED DMSCHS095E INVALID ADDRESS 'address' DMSCMS110E CORRECT FORM IS: CHSXGEN LOCATION (SEGNAME) DMSCMS111E CMSXGEN FAILEt DUE TO LOAD ERRORS DMSCHS141S CHSXGEN FAILED DUE TO SAVESYS ERRORS DMSCHS412S CMSIGEN FAILED DUE TO SET KEY ERROR DMSCHS7151 CMSXGEN COMPLETE nUMP/JDUMP/PDUMP ROUTINE DHSDHP020W INVALID PDUHP ADDRESS 'address' - NO DUMP OPERATION PERFORMED 272 IBM VH/SP System Messages and Codes DBS EXCP ROUTINE DMSXCP037E DMSXCP043E DeSXCP104S D!SXCP105S DMSXCP113S DMSXCP411s DMSXCP161S OUTPUT DISK mode (cuu) IS EEAD/ONLY TAPE (cuu) IS FILl FRO~ECTlD ERROR Inn' READING FILE 'fn ft fm' PROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK 'device (cuu) , NC~ ATT ACHlt {INPUT\OUTPUT} ERROR CODE Inn' ON 'SYSxxx' UNEXPECTED ERROR CODE Inn' ON 'SYSxxx' OS OPEN AND CLOSE ROUTINE DMSSOP036W UPDATE REQUESTlD FOR READ-ONLY DISK DMSSOP036E OPEN ERROR CODE Inn' ON 'ddname' DMSSOP109S VIRTUAL STORAGE CAPACI~Y EXCEEDED OS I/O ROUTINES DMSSEB4291 'TAPn (cuu) , EOT ON OU~PU~ TAPE LABEL PROCESSING ROUTINES DMSTLB027E INVALID DEVICE 'device name' DMSTLB043E 'TAPn (cuu) , IS FILE PROTECTED DMSTLB058E END-OF-PILE or END-OF-TAPE [ON TAPn] DMSTLB 11 OS ERROR READING 'TAPn [ (cuu) , ] DMSTLB111S ERROR WRITING 'TAFn ~uu)' DMSTLB113S 'TAPn (cuu) , NOT ATTACHED DMSTLB421E 'TAPn (cuu) , HDR1 lABEL MISSING FOR 'filename' DMSTLB422E 'TAPn (cuu) , POSITIONED WRONG FOR 'filename' DMSTLB4231 'TAPn (cuu) , POSITION PARAMETER IGNORED. OUTPUT PILE WILL BE WRITTEN IMMEDIATELY AFTER NEW VOL1 LABEL DMSTLB424E 'TAPn (cuu) , NOT POSITIONED AT EOF1 lABEL DMSTLB425R 'TAPn (cuu) , BLOCK COUNT ERRCR FOR 'filename' ENTER 'IGNORE' OR 'CANCEL' DMSTLB426R 'TAPn (cuu) , UNEXPIRED FILE ENTER 'IGNORE' OR 'ERROR' DMSTLE4271 'TAPn (cuu) , EOV1 LABEL READ DMSTLB4281 'TAPn (cuu) , EOV1 LABEL WRITTEN DMSTLB430E 'TAPn (cuu)' IABEIDEF INFORMATION MISSING FOR 'filename' DMSTLB431E 'TAPn (cuu) , VOL1 LABEL MISSING DMSTLB432E 'TAPn (cuu) , VOLID volid DeES NOT MATCH LAEELDEF VOLID FOR 'filename' D!STLB433R ENTER 'WRI~E (VOLID' OR 'REJECT' DMSTLB434E 'TAPn (cuu) , INPU~ LABEL CHECK ERROR POR PIELD 'fieldname' FILE 'filename' DMSTLB435R ENTER 'IGNORE' OR 'CANCEL' DMSTLB4361 'TAPn (cuu)' MISSING USER STANDARD LABEL POR 'ddname' DMSTLB4371 'TAPn (cuu) , NSL ROUTINE RETURNED AN ERROR CODE 'nnnnnn' FOR 'filename' SAVED SYSTEM ROUTINES DMSVIB400S SYSTEM 'sysname' tCES NeT EXIST DMSVIB401S VM SIZE (size) CANNOT EXCEED 'sysname' START ADDRESS (address) DMSVIB410S CONTROL PROGRAM ERBCR INDICATION 'retcode' DMSVIB109S VIRTUAL STORAGE CAFACI~Y EXCEEDED VSAMGEN EXEC PROCEDURE DMSVGN069E DISK 'A' NOT ACCESSED DMSVGN360E INVALID RESPONSE 'response' DMSVGN3601 CMS/VSAM TEXT FlIES CREATED eN DISK 'A' DMSVGN360R ENTER EITHER 'INS~ALL' OR 'UPDATE': DMSVGN361E DISK 'mode' IS NO~ A {CMSlteS} DISK DMSVGN3611 CREATING CMS TEX! FILES ••• D~SVGN361R ENTER EITHER 'DOS' OR 'OS': DMSVGN3621 LINK EDITING sysname DMSVGN362R ENTER MODE OP DOS SYSTEM RElOCATABLE LIBRARY DISK: DMSVGN3631 sysname DOSlIB CREATED ON DISK 'A' DMSVGN363R ENTER LOCATION WHERE sysname WILL BE LOADED AND SAVED: DMSVGN3641 FETCHING sysname ••• DMSVGN364R ENTER 'CMSVSAM' OR 'CMSAMS' OR 'BOTH' FOR GENERATION OF NEW SYSTEM(S): DMSVGN3651 SYSTEM sysname SAVED DMSVGN366E NO CMS/DOS SUPPORT FOR NATIVE 3800 DISK DMSVGN365R ONE OR MORE OF THE ~EXT FILES LISTED IN THE fn EXEC ARE MISSING. THE VSAM PP PID TAPE SHaUll EE ON TAPE DRIVE 181, ENTER 'GO' IF TAPE DRIVE IS READY TO lOADFILE OR 'QUIT' TO STOP GENERATION PROCESS DMSVGN3661 STARTING TO READ PTF DECKS PROM READER ••• DMSVGN366R ENTER NAME OF SYSTEM TC BE SAVED: DMSVGN3671 'modulename TEXT' WRITTEN ON DISK 'A' Appendix A. Command-to-Message Cross Reference 273 DMS DKSVGN3681 DMSVGN368R DKSVGN369E DKSVGN369R DMSVGN371R DMSVGN380R DMSVGN381R DMSVGN382R DMSVPD070E DMSVPD105S DMSVPD109S DMSVPD110S DMSVPD113S DMSVPD367I DMSVPD368I DMSVPD383R count MODULES HAVE BEEN RESTORED ERASE sysname DOSlIE? •• ENTER 'YES' OR 'NO': INVALID RELEASE 31 OR LATER REQUIRED ENTER RELEASE NUKEER OF tOS/VS STARTER SYSTEM: 'sysname' IS LOADED. ENTER CP KODE TO APPLY ZAPS, ELSE 'NULL' ENTER 'TAPE' OR 'CARDS' FOE PTF APPLICATION: ENTER 'SELECT' OR 'ALL' FOR TAPE PTF APPLICATION: ENTER NUMBER OF TAPE FILES TO BE PROCESSED: INVALID PARAMETER 'Farameter' ERROR 'nn' iRITING FILE 'fn CMSUT1 A1' ON DISK VIRTUAL STORAGE CAPACITY EXCEEDED ERROR READING TAP1 (181) TAP1 (181) NOT ATTACHED 'modulename TEXT' WRITTEN ON DISK 'A' count MODULES HAVE BEEN RESTORED APPLY 'fn' 1 ••• ENTER 'NC' CE EOB: VSAM INTERFACE (OS USER) DMSVIP109S VIRTUAL STORAGE CAPACITY EXCEEDED DMSVIP230E NO. OF VSAM EXIT ROUTINES HAS EXCEEDED MAX OF 128 - UNABLE TO CONTINUE 27q IBM VM/SP System Messages and Codes DM'r RSCS Message Summary DMTREXOOOI D!TCMX0011 DMTREX0021 DM"XCMX0031 DftTNPT070E DftTSftL070E D!TREX080E DMTREX090T DMTREX091T DM"XAXS1011 DMTAXS1021 RSCS (VER v, LEV 1, mm/dd/yy) RElDl FREE STORAGE = nn PAGES LINK linkid DEAC~IVATED LINK linkid EXECUTIIG: (command line text) I/O ERROR cuu SIOCC cc CSi csw SENSE sense CCW ccw I/O ERROR cuu SIOCC cc CSW csw SENSE sense CCW ccw PROGRAM CHECK -- IIIK linkid DEACTIVATED PROGRAM CHECK IN SUPERVISOR -- RSCS SHUTDOWN IN!TIALIZATION FAILURE -- ESCS SHUTDOWN PILE spoolid ENQUEUED ON LINK linkid FILE spoolid PENDING FCB LINK linkid DMTAXS103E DMTAXS1041 DM"XAXS1051 DMTAXS1061 DMTAXS1071 DMTAXS108E DM"XNPT108E DM!SML108E DMTNPT1411 DMTSML1411 FILE spoolid REJECTED -- INVALID DES~INATION ADDRESS FILE SPOOLED TO userid2 -- OEG locid1 (name1) mm/dd/yy hh:mm:ss FILE spoolid PURGED FILE spoolid MISSING -- DECUEUED FBOM LINK lin kid nn PENDING FILES FOR LINK linkid MISSING SYSTEM ERROR REAtING S~CCL PILE spoolid SYSTEM ERROR REAtING SPOOL PILE spoolid SYSTEM ERROR REAIING SFCCl FILE spoolid LINE vaddr READY FOR CONNEC~ION TO LINK linkid LINE vaddr READY FCE CCNNECTION TO LINK linkid DMTNPT1421 DMTSML1421 DMTNPT1431 DMTSML1431 DMTNPT1441 DMTSML1441 DMTNPT1451 DMTSML1451 DMTNPT1461 DMTSML1461 LINK linkid LINE vaddr CONNECTED LINK linkid LINE vaddr CCNNECTED LINK linkid LINE vaddr DISCONNECTED LINK linkid LINE vaddr DISCONNECTEt RECEIVING: FILE FROM locid1 (name1) POR locid2 (userid2) RECEIVING: PILE FRCM locid1 (name1) FOR locid2 (userid2) RECEIVED: FILE FROM locid1 (name1) FOR locid2 (userid2) RECEIVED: FILE FROM locid1 (name1) FCR locid2 (userid2) SENDING: FILE spoolid CN LINK linkid, REC nnnnnn SENDING: FILE spoolid ON LINK linkid, REC nnnnnn DMTNPT1471 DMTSML1471 DMTNPT1491 DMTSML1491 DMTNPT1601 DMTSML1601 DMTNPT1701 DM"XSML 1701 SENT: FILE spoolid CI LINK linkid SENT: FILE spoolid ON LINK linkid LINK linkid LINE ACTIVITl: TCT= mmm; ERRS= nnn; TMOUTS= ppp LINK linkid LINE AC~IVI~l: TOT= mmm; ERRS= nnn; TMOUTS= ppp LINE vaddr DISABLED FOE lin kid LINE vaddr DISABLED FOR linkid FROM linkid: (MSG message text) FROM linkid: (MSG messagE te xt) DM"XNPT190E DMTSML190E DMTNPT934E DMTSML934E DMTSML935E DMTNPT936E DMTSML937E INVALID SPOOL BlCCK FOEMA~ CN FILE spoolid INVALID SPOCL BLCCK FOEMAT CN FILE spoolid ID CARD MISSING ON LINK linkid -- INPUT FILE PURGED ID CARD MISSING CN LINK linkid -- INPUT F1LE PURGED LINK linkid IN RJE MODE -- PRINT FILE spoolid PURGED NO REMOTE PONCH AVAILABLE ON LINK linkid -- FILE SpoOlid PURGED DECOMPRESSION ERROR ON linkid -- LINK DEACTIVATED DMTCMX2001 DMTCMX201E DMTCMX202E DMTCMX203E DMTCMX204E DMTCMX20SE DMTCMX206E DMTCMX207E DMTCHX208E D"TCMX3001 DMTC"X301E DMTCMX302E DMTCHX303E DMTCMX304E RSCS INVALID COMMAND command INVALID LINK linkid INVALID SPOCL FILE ID spoolid INVALID KEYWORD keyword CONFLICTING KElWCED keyword INVALID OPTION kEyword option CONFLICTING OPTICN keyword option INVALID USER ID userid ACCEPTED BY TASK task REJECTED BY TASK task -- PREVIOUS COMBAND ACTIVE LINK linkid IS NCT DEFlNED LINK linkid IS NO~ ACTIVE REJECTED BY TASK task -- NOT RECEIVING Appendix A. Command-to-Hessage Cross Reference 215 DMT BACKSPAC DM~NPT5101 DM~SML5101 DM~NPT511E FILE spoolid EACKSPACED FILE spoolid EACKSPACED NO FILE AC~IVE ON LINK linkid DMTSML511E NO FILE ACTIVE ON LINK linkid CHANGE DMTAXS5201 FILE DM~AXS5211 FILE DMTAXS5221 FILE DM~AXS5231 LINK DM~AXS524E FILE DM~AXS525E FILE DM~AXS526E FILE spoolid CHANGED spoolid HELD FOR LINK linkid spoolid BELEASED FOB LINK linkid linkid QUEUE REORDERED spoolid ACTIVE -- NO AC~ION TAKEN spoolid IS FOR LINK linkid -- NO ACTION TAKEN spoolid NCT FCUND -- NO ACTION TAKEN CMD DM~SML530I COMMAND FOB~ABDED eN LINR linkid DEFINE DM~CMX540I DM~CMX5411 NEW LINK linkid DEIINEt LINK linkid BEDEFINED DMTCMX542E LINK linkid ACTIVE -- NOT BEDEFINEt DM~CMX543E LINK linkid NOT DEFINED LINK LIMIT BEACHED DM~CMX544E LINK linkid NOT tEFINEt -- TYPE NCT SPECIFIED DELE~E DMTCMX550I LINK linkid NO~ DELETED DM~CMX551E LINK linkid ACTIVE -- NOT DELETED DMTCMX552E LINK linkid HAS A FILE QUEUE -- NOT DELETED DIS CONN DMTCMX5601 RSCS DISCONNECTING DM~CMX561E USERID userid NO~ RECEIVING DRAIN DMTNPT570I LINK linkid DMTSML570I LINK linkid DM~NPT571E LINK linkid DMTSML571E LINK linkid NOW SE! NOW SET ALREADY ALBEADY TO DEACTIVATE TO DEACTIVATE SET TO DEACTIVATE SET TO DEACTIVATE FLUSH DMTNPT580I FILE DM~SML5801 FILE DMTNPT581E FILE DMTSML581E FILE spoolid spoolid spoolid spoolid F'REE DMTNPT5901 DMTSML590I DMTNPT591E DMTSML591E LINK LINK LINK LINK linkid linkid linkid linkid FWDSPACE DMTNPT511E DMTSML511E DMTNPT6001 DMTSML6001 NO FILE ACTIVE ON LINK linkid NO FILE ACTIVE ON LINK linkid FILE spoolid FCBWARD SPACED FILE spoolid FORWARD SPACED HOLD DMTNPT6101 DMTSML610I DMTNPT6111 DMTSML6111 DMTNPT612E DMTSML612E LINK LINK LINK LINK LINK LINK linkid linkid linkid linkid linkid linkid PBOCESSING TEEIHNATED PROCESSING TEBMINATED NOT ACTIVE NOT ACTIVE RESUlHNG FILE TRANSFER RESUMING FILE TBANSFEB NOT IN HOLD STATUS NOT IN HOLt STATOS TO SUSPEND FILE TRANSMISSION TO SUSPEND FILE TRANSMISSION FILE TRANSMISSION SUSPENDED FILE TRANSMISSION SUSPENDED ALREADY IN HOLD STATUS ALBEADY IN HOlr STATUS MSG No response. ORDER DMTAXS523I LINK linkid QUEUE REORDERED DMTAXS524E FILE spoolid ACTIVE -- NO ACiION TAKEN DMTAXS525E FILE spoolid IS FOB LINK linkid -- NO ACTION TAKEN 276 IBM VM/SP System Messages and Codes DMT DMTAIS526E FILE spoolid NeT POUND PURGE DMTAXS524E DMTAXS525E DMTAXSS26E DMTAXS640I ~- NO ACTION TAKEN FILE spoolid ACTIVE -- NO AC~ION TAKEN FILE spoolid IS FOE linkid -- NO ACTION TAKEN FILE spoolid NOT POUND -- NO ACTION TAKEN nn FILE(S) PURGEt ON LINK linkid QUERY linkid STAT DMTCMX6511 LINK linkid INACTIVE DMTCMX6521 LINK linkid ACTIVE task type vaddr c {HOI NOH} {DRINOD} {TRAITREINOT} Q=m P=n QUERY linkid DEF DMTCMI6531 LINK linkid DEFAULT task type vaddr c R=m QUERY linkid QUEUE DMTCMX6541 LINK linkid Q=m P=n DMTCMX65S1 FILE spoolid locid use rid CL a PR mm REC nnnnnn {All} QUERY FILE spoolid DMTCMX660I FILE DMTCMX6611 FILE DMTCMX664E FILE STAT spoolid INACTIVE ON LINK lin kid spoolid ACTIVE ON lINK linkid spoolid NOT FOUND QUERY FILE spoolid RSCS DMTCMX6621 FILE spoolid ORG locid1 userid1 mm/dd/yy hh:mm:ss TO locid2 userid2 DMTCMX664E FILE spoolid NO~ FOUND QUERY FILE spoolid VM DMTCMX6631 FILE spoolid PR mm CL a CO nn {HOI NOH} DI distcode, NA {fn ftldsname} DMTCMX664E FILE spoolid NCT FCUND QUERY SYSTEM DMTCMX6701 DMTCMX6711 DMTCMX6721 DMTCMX673I LINK linkid ACTIVE -- lINE vaddr {HCINOH} LINK linkid INAC~IVE NO LINK ACTIVE NO LINK DEFINED SIGNON DMTNPT902E DMTSML902E DMTNPT903E DMTSML903E DMTNPT904E DMTNPT905I DMTSML90SI NON-SIGNON CARD READ ON LINK linkid NON-SIGNON CARD REAt ON LINK linkid PASSWORD SUPPLIED ON LINK linkid IS INVALID PASSWORD SUPPLIED CN LINK linkid IS INVALID SIGNON PARAMETER=Farameter INVALID SIGNON of lINKID linkid CO~PIETE SIGNON of LINKID linkid CO!PLETE START DMTCMX7001 ACTIVATING LINK linkid task type vaddr c DMTCMX701E NO SWITCHED LINE AVAILABLE -- LINK linkid NOT ACTIVATED DMTCMX702E LINE vaddr IS IN USE BY LINK linkid1 -- LINK linkid2 NOT ACTIVATED DMTCMX703E DEV cuu IS NOT A LINE POR~ -- LINK linkid NOT ACTIVATED DMTCMX704E LINE vaddr CC=3 NOT OPERATICNAL -- LINK linkid NOT ACTIVATED DMTCMX705E DRIVER type NOT FOUND ON DISK vaddr -- LINK linkid NOT ACTIVATED DMTCMX706E FATAL ERROR LOADING FROM vaddr -- LINK lin kid NOT ACTIVATED DMTCMX707E DRIVER type FILE FCRMAT INVALID -- LINK linkid NOT ACTIVATED DMTCMX708E VIRTUAL STORAGE CAPACITY EXCEEDED -- LINK lin kid NOT ACTIVATED DMTCMX709E TASK NAME task ALREADY IN USE -- LINK linkid NOT ACTIVATED DMTCMX710E MAX (nn) ACTIVE -- LINK linkid NO~ ACTIVATED DMTNPT7S0E LINK linkid ALREADY ACTIVE -- NO ACTION TAKEN DMTSML7S0E LINK linkid ALREADY ACTIVE -- NO ACTION TAKEN DMTCMX7511 LINK linkid ALREADY ACTIVE -- NEW CLASS(ES) SET AS REQUESTED DMTNPT7521 LINK linkid STILL ACTIVE -- DRAIN STATUS RESET Appendix A. Command-to-Message Cross Reference 277 DMT DMTSML1521 LINK linkid STILL ACTIVE -- DRAIN STATOS RESET INVALID SML MCDE SFECI!I!D -- LINK linkid NOT ACTIVATED DMTSML906E INVALID SML BUFFER PARAMETER -- LINK linkid NOT ACTIVATED DMTSM~901E TRACE DMTNPT8011 LINK DMTSM~8011 LINK DMTNPT8021 LINK DMTSML8021 LINK DMTNPT8031 LINK DMTSML8031 LINK DMTNPT810E LINK DMTSML810E LINK DMTNPT811E LINK DMTSML811E LINK DMTINI402T DMTINI406R DMTINI401R DMTINI409R DMTINI410R DMTINI431S DMTINI479E DMTINI480E DMTINI481E DMTINI482E DMTINI483E 278 linkid linkid linkid linkid linkid linkid linkid linkid linkid linkid ERROR ERRCR TRACE TRACE TRACE TRAC! TRACE TRACE TRACE TRACE TRACE STARTED TRACE STARTED STARTED STARTED ENDED ENDEt ALREADY ACTIVE ALREADY ACTIVE NOT ACTIVE NCT ACTIV! IPL DEVICE READ IIC ERROR SYSTEM DISK ADDRESS = cuu REWRITE THE NUCLEUS? (IESINO) NUCLEUS CIL ADDRESS = nnn ALSO IPL CYLINDER O? (YESINO) IPL DEVICE ~RITE llC ERROR INVALID DEVICE ADtRESS -- REENTER INVALID CYLINDER NUMBEE -- REENTER INVALID REPLY -- ANSWER "YES" OR "NO" SYSTEM DISK ERROR -- REENTER NUCLEUS WILL OVERLAI CMS FILES -- RECOMPUTE IBft VM/SP System Messages and Codes DHH I pes Message Summary DUHPSCAN DHMDSC500S DMMDSC7001 DMMDSC701R DMMDSC7191 DMHDSC7201 DHMDSC7211 DMMDSC7221 DMMDSC7231 DMMFED7021 DMMFED7031 DMMFEX7041 DHMGET100S DMHGET7081 DMMHEX7141 DMMIOB7121 DMMIOE7131 DMHLOC715I DHMLOC716I DMMLOC7161 DMMLOC717I DMMMOD100S DMKMOD705E DMMMOD7061 DMMMOD707I DMMMOD7181 DMMREG100S DMMREG7241 DMMREG7241 DMMSCR7091 DMMTRC710I DMMVMB7111 ERROR 'nnn' WRITING TO VIRTUAL PRINTER TYPE HELP OR ENTER ENTER DUMP NUMEER AND MODE ERROR 'nnn' IN FSSTATE 'filename filetype fm' LOAD MAP ALREADY PRESENT SNAME TABLE IS FULL INVALID ENTRY INTO SNAME TABLE THE DUMP IS NOT CN THE A-IISR NON-HEX CHARACTER IN COUNT - RETRY NON-HEX CHARACTER IN ADDRESS - RETRY NON-HEX CHARACTER IN ADDRESS - RETRY ERROR 'nnn' READING FILE 'filename filetype fm' PAGE 'page' NOT FOUND IN DUMP NON-HEX CHARACTER IN INPUT - RETRY DEVICE 'cuu' NOT FOUND USER 'userid' VMBICR NCT FCUND NON-HEX CHARACTER IN STRING STRING 'string' NCT FOUND STRING 'string' NOT FOUND EEFORE END OF DUMP INVALID FORM OF ICCATE COMMAND ERROR 'nnn' READING FILE 'filename filetype fm' ERROR IN ITEM TAEIE 'entry name' NOT FOUND IN THE LOAD MAP 'module' 'page' PAGE NCT VALID THIS DUMP HAS NO LOAD MAP - SEE MAP SUBCOBMAND ERROR 'nnn' READING FILE 'fileid' {AP} REGISTERS REQUESTED FOR UNIPROCESSOR DUMP {MP} REGISTERS RECUESTED FCR UNIPRCCESSOR DUMP NO VALID SCROLL ADDRESS NON-NUMERIC CCUNT CHARACTEE - RETRY LOOP IN VMELOK CHAIN PRB DMMSUM100S DMMSUM200S DMMSUM501S DMMSUM502S ERROR 'nnn' READING FILE 'filename filetype fm' ERROR 'nnn' WRITING FILE 'filename filetype fm' INVALID PARM 'tadpaLm' PASSED TO SUMMARY UPDATE PROGRAM PBOBLEM 'PREnnnnn' NOT FOUND IN SYMPTOM SUMMARY PROB DMMPR0100S DMMPR0200S DMMPR0300S DMMSEA100S DMHSUM100S DMMSUM200S DMMSUM501S DMMSUM502S DMMWRT200S ERROR 'nnn' READING FILE 'filename filetype fm' ERROR 'nnn' WRITING FILE 'filename filetype fm' ERROR 'nnn' ON FSST!TE 'filename filetype fm' ERROR 'nnn' READING FILE 'filename filetype fm' ERROR 'nnn' READING FILE 'filename filetype fm' ERBOR 'nnn' WRITING FILE 'filename filetype fm' INVALID PARM 'badparm' PASSED TO SUMMA~Y UPDATE PROGRAM PROBLEM 'PRBnnnnn' NOT FOUND IN SYHPTOM SUMMARY ERROR 'nnn' WRITING FILE 'filename filetype fm' STAT DMMSTA100S ERROR 'nnn' READING FILE 'filename filetype fm' DMMSTA200S ERROR 'nnn' WRITING FILE 'filename filetype fm' DMMSTA6011 OPERAND 'operand' NCT EECCGNIZED VMFDUMP DMMCPA8051 DMMEDM8501 DMMEDM8511 DMHEDM8521 DMMEDM8531 DMMEDM8601 DMMEDM8611 DMMEDM863E DMMEDM8641 DMMGRC100S DMMGRC8091 DMMINI100S DMMINI200S DMHINI300S 'nnn' ABEND CODE NOT RECOGNIZED BY DATA EXTRACTION UNABLE TO READ DUMP FROM READER TEN DUMP FILES ALREADY EXIST FATAL I/O ERROR WRITING DUMP NO DUMP FILES EXIST FATAL I/O ERROR REAIING DUMP DUMP FILE 'filename' NCT FCUND INVALID PARAMETER - paLameteL PAGE REFERENCED NCT AVAIIAEIE WHILE EDITING xxxxxxxx ERROR 'nnn' READING FILE 'filename filetype fm' REQUESTED ADDRESS NCT IN DUMP ERROR 'nnn' READING FILE 'filename filetype fm' ERROR 'nnn' WRITING FILE 'filename filetype fm' ERROR 'nnn' ON FSSTATE 'filename filetype fm' Appendix A. Command-to-Message Cross Reference 279 DMM DMMINI400S DMMINI800S DMMINI803S DMMMAP200S DMMMAP8011 DMMMAP8021 DMMMAP806R DMMMAP8071 DMMMAP8081 DMMMAP8101 DMMPRM200S DMMPRM8041 DMMSEA100S DMMSUM100S DMMSUM200S DMMSUM501S DMMSUM502S DMMWRT200S 280 ERROR 'nnn' CLOSING 'filename filetype fm' DATA EXTRACTICN FAILURE ERROR 'nnn' A~TEMP~ING ~O LOADMOD VMFDUMP2 ERROR 'nnn' WRITING FILE 'filename filetype fm' NUC MAP 'filename filetype fm' IS NOT VALID FOR THIS DUMP PROCEEDING •••• ENTER 'filename filetype fm' OF NUCLEUS LOAD MAP OR ENTER NULL UNABLE TO LOCATE 'filename filetype fm' NUCLEUS MAP INVALID 'filename filetype fm' ERROR 'nnn' READING FILE 'filename filetype fm' ERROR 'nnn' WRITING FILE 'filename filetype fm' PROCESSING ERROR IN DATA EXTRACTION ERROR 'nnn' READING FILE 'filename filetype fm' ERROR 'nnn' READING FILE 'filename filetype fm' ERROR 'nnn' WRITING FILE 'filEname filetype fm' INVALID PARM 'badparm' PASSED TO SUMMARY UPDATE PROGRAM PROBLEM 'PREnnnnn' NOT FOUND IN SYMPTCM SUMMARY ERROR 'nnn' WRITING FILE 'filEname filetype fm' IBM VM/SP System Messages and Codes DfilK Appendix B: Message Summary Alphamerically by Message Identifier This appendix lists the messages issued by CP, CMS, RSCS, and IPCs. The lists are organized alphamerically, in order by module code, message number, and type. Note: RsCs and IPCs messages 6leve!. remain at the VM/370 Release CP Message Summary DKKAC0425A PUN cuu ACCOUNTING DA~A; FA~Al I/O ERROR DKKAC0425E I/O ERROR DURING ACCCONTING DKKACR149E DEVICE PATH radar PROC addr PRESENTED cc3 ON I/O REQUEST DKKACR603W CHANNEL ERROR; RUN sEREP, REstART SYSTEM DKKACR622W MACHINE CHECK; MULTIPLE CHANNEL ERRORS DKKALG059E AUTOLOG FAILED FOE userid-{IPl HIssINGIIPL F~LEDIACCOUNTING ERROR INCORRECT PAsSiORD} DKKALG115E AUTOLOG INVALID; EXCESSIVE INCORRECT FAssWORDS DMKATs181E SHARED SYSTEM name REPLACED WITH NON-SHARED COpy DMKBLD200E VIRT=REAL AREA NOT AVAILABLE; IN USE BY {useridISysTEM} DMKBLD201E VIRT=REAL AREA NOT AVAILAEIE; EAMAGEt PAGES DMKBLD202E VIRT=REAL AREA NOT AVAILAELE; INSUFFICIENT STORAGE DKKBsC5001 type 'addr' CMD REJECT CMD='cm' SNS='sense' CSW='csw' UsERID='userid' [ {BBCCHH='bbcchh'IEICC~='nnnnnn'}] DKKBSC501A type 'addr' INT REQ CMD='cm' SNS='sense' CsW='csw' USERID='userid' [(BBCCHH='bbcchh'IBICC~='nnnnnn') ] DMKBsC5021 type 'addr' BOsOUT CK CMD='cm' SNS='SENSE' CSW='csw' OSERID='userid' [ {BBCCHH='BBCCHH'IBLOCK='nnnnnn'}] DMKBsC5031 type 'addr' EQUIP CK CMD='cm' SNS='sense' CSW='csw' OSERID='userid' [ (BBCCHH=' bbcchh' I BLOCK=' nnnnnn ') ] DKKBsC5041 type 'addr' DATA CK CHD='cm' SNS='sense' CsW='csw' USERID='userid' [ (BBCCHH='bbcchh'IBICCR=lnnnnnn')] DHKBSC5051 type 'addr' OVERRUN CK CMD='cm' sNS='sense' CSW='csw' USERID='userid' [ (BBCCHH='bbcchh'IELCCK='nnnnnn')] DKKBsC5161 type 'addr' BAD SENSE CMD='cm' SNS='sense' CSW='csw' USERID='userid' [(~BCCHH='bbcchh'IEICC~='nnnnnn') ] DMKBsC5171 {LINEITAPE} 'adar' NOT/KNOWN CMD='cm' SNS='sense' CsW='cs~' USERID='userid' DMKBsC5201 type 'addr' CHAN ERROR CMD='cm' sNS='sense' CSW='csw' USERID='userid' [ (BBCCHH='bbcchh'IBICCR='nnnnnn')] DMKBsC5271 {LINEICONS} 'addr' lOSt DATA CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKBSC5281 {LINE ICONS} 'addr' TIMEOUT CHD='cm J SNs='sense' CSW='csw' USERID=luserid' DMKCCB6011 DMKCCH6021 DKKCCH603W DKKCCH6051 CHANNEL CONTROL CHECK DEV xxx; USER 'userid' INTERFACE CONTROL CHECK DEV xxx; USER 'userid' CHANNEL ERROR; RUN SEREP, RESTART SYSTEM CHANNEL CHECK RECORDING FAILURE DKKCDB003E DMKCDE004E DKKCDB009E DMKCDB010E DKKCDB026E DKKCDB160E INVALID OPTION - ~ption INVALID HEXLOC - hexlcc INVALID RANGE - range INVALID REGISTER - register OPERAND MISSING OR INVALlt HEXLOC hexloc EXCEEDS STORAGE DKKCDft003E DMKCDK004E DMKCDM009E DKKCDM033E DMKCDM060E DKKCDM061E INVALID OPTION - option INVALID HEXLOC - hexlcc INVALID RANGE - range HEXLOC KISSING OR INVALID DUMP FAILED; VIRTUAL PRINTER UNAVAILABLE DUMP FAILED: VIRTUAL PRINTER ERROR Appendix B. ftessage Summary Alphamerically by Message Identifier 281 DMK DMKCDM160E HEXLOC hexloc EXCEEDS STORAGE DMKCDSOOqE DMKCDSOOSE DMKCDS010E DMKCDS012E DMKCDS026E DMKCDS033E DMKCDS160E DMKCDS161E DMKCDS162E DMKCDS162W DMKCDS163E DMKCDS164E DMKCDS166E INVALID HEXLOC - operand INVALID HEXDATA - hexdata INVALID REGISTER - register INVALID PSW - psw OPERAND MISSING OR INVALID HEXLOC MISSING OR INVALID HEXLOC hexloc EXCEE£S STORAGE SHARED PAGE hexloc ALTERED by userid INVALID ECR x - hexdata INVALID ECE x - hex data STORE EXCEEDS MAXIMUM EEGISTEB HEXLOC hexloc NON-ADDRESSABLE STORAGE CHANGED SHARED PAGE NCT WEITTEN TO AUXILIARY STORAGE DMKCFC001E DMKCFC002E DMKCFC004E DMKCFC026E ?CP: command INVALID OPERAND - operand INVALID HEXLOC - hex lee OPERAND MISSING OR INVALID DMKCFD004E DMKCFD021E DMKCFD022E DMKCFD026E DMKCFD040E DMKCFD160E DMKCFD164E INVALID BEXLOC - hexlec RADDR MISSING OR INVALID VADDR MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIST HEXLOC hexloc EXCEEDS STOEAGE HEXLOC hexloc NON-ADDRESSABLE STORAGE DMKCFG002E DMKCFG003E DMKCFG013E DMKCFG022E DMKCFG026E DMKCFG040E DMKCFG04QE DMKCFG083E DMKCFG170E DMKCFG171E DMKCFG172E DMKCFG173E DMKCFG17QE DMKCFG17SE DMKCFG177E DMKCFG179E DMKCFG203E INVALID OPERAND - operand INVALID OPTION - option CONFLICTING OPTION - option VADDR MISSING OR INVALID OPERAND MISSING OB INVALID DEV addr DOES NOT EXIST SYSTEM name DOES NCT EXIST VMSAVE AREA DOES NOT CONTAIN A VALID SAVED SYSTEM SYSTEM name EXCEEDS STCRAGE SYSTEM name VOLID valid NOT MCUNTED SYSTEM name DASD vaddr INCOMPATIBLE SYSRES SYSTEM name REQUIRES DASD vaddr PAGING I/O ERROR; 1FL PAlLED {FAVOREDIRESERVEINETWORK TRACElname} ALREADY IN USE BY userid PARM EXCEEDS 64 CHARACTERS SYSTEM name VOLID valid NeT CP CWNED V=R AREA REQUIRES IPL EY DEVICE ADDRESS DMKCFH026E DMKCFHOQ4E DMKCFH170E DMKCFH171E DMKCFH172E DMKCFH173E OPERAND MISSING OR INVALID SYSTEM name DOES NOT EXIST SYSTEM name EXCEEDS STCRAGE SYSTEM name VOLID valid NOT MCUNTED SYSTEM name DASD vaddr INCOMPATlBLE SYSRES SYSTEM name REQUIRES DASD vaddr D~KCFH179E SYSTE~ name VOLID valid NCT CP CWNED DMKCFH300E SAVE REQUEST BEYOND VIRTUAL MACHINE SIZE D~KCFH43SE PAGING ERROR WRITING SAVED SYSTEM DMKCFH436E INTERRUPT PENDING. TO PROCEED, TYPE YES. TO END, TYPE NO. DMKCFC003E DMKCF0006E DMKCF0013E DMKCl0020E DMKCF0021E DHKCF0026E DMKCF0040E DMKCFOOQ1E DMKCFOOQSE DMKCl0046E DMKCF0140E DMKCF0143E DMKCF0175E DHKCF0184E DMKCF0186E 282 IBM INVALID OPTION - option INVALID DEVICE TYPE - addr CONFLICTING OPTION - option USERID HISSING OR INVALID RADDR MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIST LOGMSG nn DOES NOT EXIST userid NOT LOGGED ON {DEV residltype raddr} OFFLINE type raddr ATTACHED TC userid type raddr IN USE BY SYSTEM {FAVOREDIRESERVEINETWOEK TRACElname} ALREADY IN USE BY userid VM ASSIST NOT AVAILAEIE [CN PROCESSOR p~oc addr] CP ASSIST NOT AVAILAELE V~/SP System Messages and Codes DMK DMKCF0188E DMKCF0199E DMKCF0250E DMKCF0255W DMKCF09251 DMKCF09251 DMKCF09531 SPECIFIED PROCESSOR UNAVAILABLE COMMAND REJECTED; DEVICE raddr PENDING OFFLINE 370E IS NOT AVAILABLE (ON PROC xx) 370E FEATURE NOi DISABLED SYSTEM AUTO DUMP REALLOCAiED TO DASD RADDR SYSTEM AUTO DUMP REALICCATED TO DASD raddr UNABLE TO ALLOCATE SYSiEM AUTO DUMP DMKCFPOq6E DMKCFP16QE DMKCFP179E DMKCFPQ35E {DEV ridltype raddr} CFFLINE HEXLOC hexloc NON-ADDRESSABLE SiORAGE SYSTEM name VOLID volid NCT CP OWNED PAGING ERROR WRITING SAVED SYSTEM DMKCFS003E DMKCFS006E DMKCFS026E DMKCFSOQQE DMKCFSOQ5E DMKCFSOQ6E DMKCFS052E DMKCFS053E DMKCFS086E DMKCFS170E DMKCFS171E DMKCFS175E DMKCFS179E DMKCFS183E DMKCFS18QE DMKCFS187E DMKCFS188E DMKCFS1891 DMKCFS1901 DMKCFS205E DMKCFS250E DMKCFS251E INVALID OPTION - option INVALID DEVICE TYPE - addr OPERAND MISSING OR INVALID SYSTEM name DOES NOi EXISi userid NOT LOGGED ON {DEV ridltype raddr} OFFLINE ERROR IN CP DIRECTORY userid NOT IN CP DIRECTORY I/O ERROR ON DASI SYSTEM name EXCEEDS STORAGE SYSTEM name VOLID valid NCT MCUNTED {FAVOREDIRESERVEINETWORK TRACElname} ALREADY IN USE BY userid SYSTEM name VOLID volid NCT CP CWNED VM ASSIST NOT ACTIVE VM ASSIST NOT AVAILAELE TIMER ASSIST NOT AVAILABLE SPECIFIED PROCESSOR UNAVAILAEIE AFFINITY NOT SET; SYSiEM IN UNIPROCESSOR MODE NO AFFINITY SPECIFIEt IN DIRECTORY DAT IGNORE NOT SET; INVALID TRANSLATION FORMAT 370E IS NOT AVAILABLE (ON PRCC xx) 370E IS NOT ACTIVE DMKCFT002E INVALID OPERAND - operand DMKCFT006E INVALID DEVICE TYPE - addr DMKCFT026E OPERAND MISSING OR INVALID DMKCFV062E DMKCFV063E DMKCFV080E DMKCFV082E ECMODE NOT SET ON SHADOW TABLE BYPASS; NCT SET NO PREALLOCATED VMSAVE AREA MORE THAN ONE VMS AVE AREA ALLOCATED; MUST SPECIFY AREA NAME DMKCFW002E INVALID OPERAND - o~erand DMKCFW026E OPERAND MISSING OR INVALID DMKCKP5361 DMKCKP900W DMKCKP901W DMKCKP902W DMKCKP910W DMKCKP911W DMKCKP922W DMKCKP9601 DMKCKP961W cuu REPORTS DISABLED INTERFACE; FAULT CODE = eccc; NOTIFY CE SYSTEM RECOVERY FAILURE; PRCGEAM CHECK SYSTEM RECOVERY FAILURE; MACHINE CHECK, RUN SEREP SYSTEM RECOVERY FAILURE; FATAL I/O ERBOR-{NUCL AREAl WARM AREA} SYSTEM RECOVERY FAILURE: INVALID WARM START AREA SYSTEM RECOVERY FAILURE: WARM START AREA FULL SYSTEM RECOVERY FAILURE; INVALID SPOOLING DATA SYSTEM WARM START DATA SAVED SYSTEM SHUTDOWN COMPLETE DMKCKS4001 SYSTEM {TEMP SPACEICBECKPOINT AREA} FULL DMKCKS915E PERMANENT I/O ERROR CN CHECKPCINT AREA DMKCKS919E CHECKPOINT AREA INVALID; CHECKPOINTING TERMINATED DMKCKT401I SYSTEM {TEMP SPACEICBECKPCINT AREA} 90 PERCENT FULL DMKCKT4381 SPOOL FILE ID LIMIT EXCEEDED DMKCKT903W SYSTEM RECOVERY FAILURE; VOLID 'volid' ALLOCATION ERROR {CYLINDER='cylinder'IPAGE='page'} DMKCKT912W SYSTEM RECOVERY FAILURE; VOLID 'volid' NOT MOUNTED DMKCKT916E ERROR ALLOCATING SPCCL FILE BUFFERS DMKCKV4011 DMKCKV912W DMKCKV915E DMKCKV916E SYSTEM {TEMP SPACEICBECKPOINT AREA} 90 PERCENT FULL SYSTEM RECOVERY FAILURE; VOIID 'volid' NOT MOUNTED PERMANENT I/O ERROR ON CHECKPOINT AREA ERROR ALLOCATING SPOOL FILE BUFFERS Appendix B. Message summary Alphamerically by Message Identifier 283 DMK DMKCKV917E CHECKPOINT AREA INVALID; CLEAE STORAGE AND COLD START DMKCLK437E SYSTEM PAGING SPACE NOT AVAILABLE, IPl TERMINATED DMKCLK970W TOD CLOCK SYNC CHECK RECEIVED DMKCNS454I {LINE addriDEV rid} ~ISABIED DMKCNS4551 LINE addr NOT OPERATICNAL' text DMKCNS5001 type 'addr' CMD REJECT CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbccbb' I BICCK=' nnnnnn '} ] DMKCNS501A type 'addr' INT REQ CMD='cm' SNS='sense' CSW='csw' USERID='userid' [{BBCCHH='bbccbb'IBLOCK='nnnnnn'} ] DMKCNS5011 {CONIPRTIPUNIRDR} 'addr' INT EEQ [CMD='cm' SNS='sense' CSW='csw' USERID='userid'] DMKCNS5021 type 'addr' BUSOUT CK CMD='CM' SNS='SENSE' CSW='csw' USERID='userid' [ {BBCCHH=' BBCCHH' I BICC:K=' nDnnnn '} ] DMKCNS503I type 'addr' EQUIP CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbccbb ' I BLOCK=' DDnnnn ') ] DMKCNS5041 type 'addr' DATA CK C~D='cm' SNS='sense' CSW='csw' USERID= 'userid' [{BBCCHH='bbcchh' IBLCCK='nnDnnn')] DMKCNS5051 type 'addr' OVERRUN CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbcchh' I BLOCK=' DnnnDD '} ] DMKCNS5271 {LINEICONS} 'addr' LOST DATA CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKCNS5281 {LINEICONS) 'addr' TIMEOUT CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKCPE005E DMKCPB006E DMKCPB012E DMKCPB022E DMKCPE026E DMKCPB040E INVALID HEXDATA - bexdata INVALID DEVICE TYPE - addr INVALID PSW - psw VADDR MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIST DMKCPI131E DMKCPI185E DMKCPI536I DMKCPI913I DMKCPI9141 DMKCPI923I DMKCPI924I DMKCPI950A DMKCPI9511 DMKCPI9521 DMKCPI9531 DMKCPI954E DMKCPI955W DMKCPI9571 DMKCPI9581 DMKCPI959W DMKCPI961W DMKCPI962I DMKCPI963I DMKCPI9641 DMKCPI9681 DMKCPI9711 INSUFFICIENT FREE STORAGE AVAILABLE FCR {ATTACHILOGON} REQUEST CP ASSIST LEVEL xx DOES NeT MATCH CP LEVEL yy CUU REPORTS DISABLED INTERFACE; FAULT CCDE = cccc; NOTIFY CE CP OWNED VOLID xxxxxx INVALID FOR 3330V TRACE TABLE IS SMALLER THAN REQUESTED FAILING STORAGE FRAME AT LOCATICN raddr xxxx ADDITIONAL FAILING STORAGE FRAMES EXIST OPERATOR NOT LOGGED ON; EXPLICIT LOGCN REQUIRED CP VOLID valid NCT MCUNTEt nnnnnK SYSTEM STORAGE UNABLE TO ALLOCATE SYSTEM AUTO DUMP DASD raddr VOLID valid NOT MOUNTED; DUPLICATE OF DASD raddr INSUFFICIENT STORAGE FCR VM/SP STOR sssssK, NUC nnnK, DYN dddddK, TRA tttK, FREE ffffK, V=R vvvvvK ATTACHED PROCESSOR NeT OPERATIONAL ATTACHED PROCESSOR NOT ONLINE SYSTEM SHUTDOWN COMPLETE CP OWNED DASD cuu VOLID valid INVALID ALLOCATION RECORD SECOND PROCESSCR NOT CNLINE PROC xx INITIALIZED; PROC yy INITIALIZED NO WARMSTART, PREVIOUS DATA STILL VALID SYSTEM IS [UPIAPIMP] GENERATED DMKCPJ2291 USER OF MONITOR DCES NeT EXIST DMKCPJ9661 INITIALIZATION COMPLETE DMKCPJ9671 DISCONNECT userid - SYSTEM RESTARTED (mmmnnn) AND SYSTEM CONSOLE NOT VM OPERATOR CONSOLE DMKCPC049E DMKCPOO49E DMKCP0124E DMKCP0124E DMKCP0140E DMKCP0140E DMKCP0142E DMKCP0142E DMKCP0143E DMKCP0143E DMKCP0198W type type DASD DASD type type type type type type LAST raddr IN USE raddr IN USE raddr IN USE BY nnn USERS raddr IN USE BY nnn USERS raddr ATTACHED TO userid raddr ATTACHED TC userid raddr NOT DRAINED raddr NOT DRAINEt raddr IN USE BY SYSTEM raddr IN USE BY SYSTEM PATH TO DEVICE raddr ON PRCCESSOR nn DMKCPP6231 CHANNEL SET CONNECTED TO PROCESSOR nn DMKCPS144W type vaddr RESET BY use rid 284 IBM VM/SP System Messages and Cades DMK DMKCPT003E DMKCPT021E DMKCPT026E DMKCPT040E DMKCPT046E DMKCPT049E DMKCPT049E DMKCPT123E DMKCPT124E DMKCPT136E DMKCPT140E DMKCPT142E DMKCPT143E DMKCPT154E DMKCPT192E DMKCPT601E DMKCPT602E INVALID OPTION - option RADDR MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIS~ {DEV ridltype raddr} CFFLINE LINE addr IN USE LINE addr IN USE DASD raddr CP OWNED DASD raddr IN USE BY nnn USERS DEVICE {vaddrlraddr} NOT {DEFINEDIVARIED}; CHANNEL XX DEDICATED type raddr ATTACHED TO userid type raddr NOT DRAINED type raddr IN USE EY SYSTEM DEV raddr VARY FAILED, VARY IN FROCESS VARY PROCESSOR COMMAND FAllEt CHANNEL CONTROL CHECK DEV xxx; USER 'userid' INTERFACE CONTROl CHECR DEV xxx; USER 'userid' DMKCPU021E DMKCPU191E DMKCPU192E DMKCPU1931 DMKCFU1941 DMKCPU812E RADDR MISSING OR INVALID PROCESSOR nn DOES NeT EXIST VARY PROCESSOR COMMAND FAILED PROCESSOR nn ONLINE PROCESSOR nn OFFLINE MSSF RESPONSE CODE TC VARY CP {CNIOFF} IS nnnn DMKCPV003E DMKCPV004E DMKCPV006E DMKCPV007E DMKCPV009E DMKCPV020E DMKCPV021E DMKCPV026E DMKCPV033E DMKCPV040E DMKCPV045E DMKCPV046E DMKCPV140E DMKCPV160E DMKCPV1651 DMKCPV176E DMKCPV199E DMKCPV202E DMKCPV203E DMKCPV204E DMKCPV9231 DMKCPV9241 INVALID OPTION - option INVALID HEXLOC - hex lac INVALID DEVICE TYPE - addr INVALID USERID - userid INVALID RANGE - range USERID MISSING OR INVALID RADDR MISSING OR INVALID OPERAND MISSING OR INVALID HEXLOC MISSING OR INVALID DEV addr DOES NOT EXIST userid NOT LOGGED ON {DEV ridltype raddr} CFFLINE type raddr ATTACHED TO userid HEXLOC hexloc EXCEEIS STORAGE PAGE hexloc NOT LOCKED; SHAREr FAGE VIRT=REAL AREA IN USE EY userid COMMAND REJECTED; DEVICE raddr PENDING OFFLINE VIRT=REAL AREA NOT AVAILABLE; INSUFFICIENT STORAGE V=R AREA REQUIRES IPL EY DEVICE ADDRESS INVALID PAGE(S) SPECIFIED, V=R AREA FAILING STORAGE FRAME AT LOCATION raddr xxxx ADDITIONAL FAILING STORAGE FRAMES EXIST DMKCQG020E DMKCQG022E DMKCQG027E DMKCQG028E DMKCQG040E DMKCQG042E DMKCQG045E USERID MISSING OR INVALID VADDR MISSING OR INVALID SPOOLID MISSING OR INVALID CLASS MISSING OR INVALID DEV addr DOES NOT EXIST SPOOLID nnnn DOES NO~ EXIST userid NOT LOGGED ON DMKCQH013E CONFLICTING OPTION - option DMKCQH024E {CYLSIBLKSIFORM NUMEER} MISSING DMKCQP003E DMKCQP006E DMKCQF020E DMKCQP021E DMKCQP022E DMKCQP040E DMKCQP045E DMKCQP4661 INVALID OPTION - option INVALID DEVICE TYPE - addr USERID MISSING OR INVALID RADDR MISSING OR INVALID VADDR MISSING OR INVALID DEV addr DOES NOT EXIS~ userid NOT LOGGED ON CTLR cuu IN BUFFER SlCWDOWN MCDE DMKCQR003E DMKCQR020E DMKCQR026E DMKCQR028E DMKCQR045E INVALID OPTION - option USERID MISSING OR INVALID OPERAND MISSING OR INVALID CLASS MISSING OR INVALID userid NOT LOGGED ON OR INVALID Appendix B. Message Summary Alphamerically by Message Identifier 285 DMK DMKCQ5002E INVALID OPERAND - operand DKKCQY020E U5ERID MISSING OR INVALID DMKCQY026E OPERAND MISSING OR INVALID DMKCQY045E userid NOT LOGGED ON DMKCSE003E DMKCSE006E DMKCSE013E DMKCSE021E DMKCSE022E DMKCSB026E DMKCSE028E DKKCSB031E DMKCSE036E DKKCSB040E DMKCSB043E DMKCSE046E DMKCSE140E DMKCSB142E DKKCSB148E INVALID OPTION - option INVALID DEVICE TYPE - addr CONFLICTING OPTION - option RADDR MISSING OR INVALID VADDR MISSING OR INVALID OPERAND MISSING OR INVALID CLASS MISSING OR INVALID BUFFER MISSING OR INVALID INDEX MISSING OR INVALID DEV addr DOES NOT EXIST EUFFER name DOES NOT EXIST {DEV ridltype raddr} CFFLINE type raddr ATTACHED ~O userid type raddr NOT DRAINED type raddr BUFFER LOAD name FAILED DKKCS0003E DKKCS0006E DMKCSC013E DKKCSC021E DKKCS0024E DMKCSC028E DMKCS0030E DKKCSC040E DMKCS0046E DMKCS0140E DMKCS0141E DKKCS0243E DKKCS0244E DMKCS0245E DMKCS0246E DMKCSC441E INVALID OPTION - option INVALID DEVICE TYPE - addr CONFLICTING OETICN - option RADDR MISSING OR INVALID {CYLSIBLKSIFORft NUMEER} MISSING OR INVALID CLASS MISSING OR INVALID COPIES MISSING OR INVALID DEV addr DOES NOT EXIST {DEV ridltype raddr} CFFLINE type raddr ATTAC2ED TO userid type raddr NOT ACTIVE FLASH MISSING OR INVALID IMAGE LIBRARY MISSING CR INVAlID CHARS MISSING OR INVALID FCB MISSING OR INVAlID NOT ACCEPTED. PREVIOUS BACKSPACE STILL BEING PROCESSED DMKCSP003E DKKCSP006E DMKCSP007E DKKCSF013E DMKCSP020E DKKCSP022E DMKCSP024E DKKCSP026E DKKCSP028E DMKCSP029E DMKCSP030E DMKCSE032E DMKCSP040E DMKCSP053E DKKCSP243E DMKCSE245E DMKCSP246E DMKCSE253E INVALID OPTION - cption INVALID DEVICE TYPE - addr INVALID USERID - userid CONFLICTING OPTION - opticn USERID MISSING OR INVALID VADDR MISSING OR INVALID {CYLSIBLKSIFORM NUMfER} MISSING OPERAND MISSING OR INVALID CLASS MISSING OR INVALID FNAME FTYPE MISSING OR INVALID COPIES MISSING OR INVALID DIST CODE MISSING OR INVALID DEV addr DOES NOT EXIST userid NOT IN CP DIRECTORY FLASH KISSING CR INVALID CHARS MISSING OR INVALID FCB MISSING OR INVALID MODIFY MISSING OR INVALID DMKCSQ024E {CYLSIBLKSIFORK NUMEER} MISSING OR INVALID OR INVALID DMKCST003E DKKCST006E DKKCST022E DMKCST026E DKKCST027E DMKCST040E DMKCST042E DKKCST424E INVALID OPTION - option INVALID DEVICE TYPE - addr VADDR MISSING OR INVALID OPERAND MISSING CR INVALID SPOOLID MISSING OR INVALID DEV addr DOES NOT EXIST SPOOLID nnnn DOES NO~ EXIST RDR FILE SPOOL ERROE; FILE UNCHANGED DMKCSU003E DKKCSU006E DMKCSU007E DKKCSU008E INVALID INVALID INVALID INVALID 286 OPTION - cpt ion DEVICE TYPE - addr USERID - userid SPOOLID_-spoolid IBM VM/SP System Kessages and Codes DMK DMKCSU013E DMKCSU020E DMKCSU02QE DMKCSU026E DMKCSU027E DMKCSU028E DMKCSU029E DMKCSU030E DMKCSU032E DMKCSU035E DMKCSUOQ2E DMKCSU053E DMKCSU2Q3E DMKCSU245E DMKCSU246E DMKCSU253E CONFLICTING OPTION - oFticn USERID MISSING OR INVALID {CYLSIBLKSIFORM NUMBER} MISSING OPERAND MISSING OR INVALID SPOOLID MISSING OR INVALID CLASS MISSING OR INVALID FNAME FTYPE MISSING CR INVALID COPIES MISSING OR INVALID DIST CODE MISSING OR INVALID DEVICE TYPE MISSING OR INVALID SPOOLID nnnn DOES NOT EXIST userid NOT IN CP DIREC~ORY FLASH MISSING OR INVALID CHARS MISSING OR INVALID FCB MISSING OR INVALID MODIFY MISSING OR INVALID DMKCSV013E CONFLICTING OPTICN - option DMKCSV024E {CYLSIBLKSIFORM NUMBER} MISSING OR INVALID OR INVALID DMKDAD500I type 'addr' CMD REJECT CMD='cm' SNS='sense' CSW='csw' USERID='userid [ {BBCCHH=' bbccbb' I BLOCK=' nnnnnn '} ] DMKDAD501 type 'addr' INT REQ C~D='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbccbh'IBLCCK='nnnnnn'}] DMKDAD5021 type 'addr' BUSOUT CK CMD='CM' SNS='SENSE' CSW='csw' USERID='userid' [{BBCCHH='BBCCHH',BICCK='nnnnnn'} ] DMKDAD503I type 'addr' EQUIP CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IBLOCK='nnnnnn'}] DMKDAD504I type 'addr' DATA CK CMD='cm' SNS='sense' CSW='csw' USERID= 'userid' [ {BBCCHH=' bbcchh' I BLOCK=' nnnnnn '} ] DMKDAD5051 type 'addr' OVERRUN CK CMD='cm' SNS='sense' CSW='csw' USERID= 'userid' [ {BBCCHH=' bbcchh' I BLOCK=' nnnnnn '} ] DMKDAD5061 DASD 'addr' TRKCOND CK CHD='cm' SNS='sense' CSW='csw' USERID='userid' BBCCHH='bbcchh' DMKDAD5081 {DASDIRDRIPRTIPUN} 'addr' FER! ERROR CMD='cm' SNS='sense' CSW='csw' USERID='userid' [BBCCHH='bbccbh'] DMKDAD5131 {DASDITAPE} 'addr' FILE PROT CMD='cm' SNS='sense' CSW='csw' USERID='userid' [{BBCCHH='bbccbb'IBI0CK='nnnnnn'}] DMKDAD5161 type 'addr' BAD SENSE CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbcchh' I BICCK=' nnnnnn '} ] DHKDAD517I {LINEITAPE} 'addr' NOT/KNOiN CMD='cm' SNS='sense' CSW='csw' USERID='userid' DHKDAD5181 {DASDITAPE{ 'addr' RECV EEECR CHD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbcchh' I BLCCR=' nnnnnn'} ] DMKDAD5201 type 'addr' CHAN ERROR CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchb',BICCR='nnnnnn'}] DMKDAD5361 cuu REPORTS DISABLED INTERFACE; FAULT CODE = cccc; NOTIFY CE DMKDAD5381 type 'addr' PROG ERROE CMD='cmd' SNS='sense' CSW='csw' USERID='userid' DMKDAD956A DASD cuu VOLID volid NOT MOUNTED; NOW OFFLINE DMKDAS5001 type 'addr' CMD REJECT CHD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbccbh ' I BICCR=' nnnnnn'} ] DMKDAS501 type 'addr' INT REQ CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IBIOCR='nnnnnn'}] DMKDAS5021 type 'addr' BUSOUT CK CMD='CH' SNS='SENSE' CSW='csw' USERID='userid' [ {BBCCHH='BBCCHH',BI0CK='nnnnnn'}] DMKDAS5031 type 'addr' EQUIP CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbcchh' I BLOCK=' nnnnnn '} ] DMKDAS50QD {DASDITAPE} 'addr' DATA CK CHD='cm' SNS='sense' CSW='csw' USERID='userid' {BBCCHH='bbcchh'} DMKDAS5041 type 'addr' DATA CK CHD='cm' SNS='sense' CSW='csw' USERID='userid' [{BBCCHH='bbcchh'IBICCR='nnnnnn'} ] DMKDAS505D {DASDITAPE} 'addr' OVERRUN CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbccbh'IBICCR='nnnnnn'}] DMKDAS5051 type 'addr' OVERRUN CK CMD='cm' SNS='sense' CSW='csw' USERID= 'userid' [ {BBCCHH=' bbccbh' I BLOCK=' nnnnnn t} ] DMKDAS5061 DASD 'addr' TRKCOND CR CMD='cm' SNS='sense' CSW='csw' USERID='userid' BBCCHH=' bbcchh, DMKDAS507D DASD 'addr' SEEK CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' BBCCHH='bbcchh' DMKDAS5081 {DASDIRDRIPRTIPUN} 'addr' FERM ERROR CMD='cm' SNS='sense' CSW='csw' USERID='userid' [BBCCHH='bbccbh'] DMKDAS509I DASD 'addr' TRKOVERUN CMD='cm' SNS='sense' CSW='csw' USERID='userid' BBCCHH='bbcchh' DMKDAS5131 {DASDITAPE} 'addr' FILE PReT CMD='cm' SBS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchb'IBLOCK='nnnnnn'}] DMKDAS514D DASD 'addr' ADDMRK CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' BBCCHH='bbcchh' Appendix B. Message Summary Alphamerically by Message Identifier 287 DMK DMKDAS5l61 type 'addr' BAD SENSE CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IBICCK='nnnnnn'}] DMKDAS5l1E DASD 'addr' NOT/KNOWN CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IELOCK='nnnnnn'}] DMKDAS5l81 {DASDITAPE{ 'addr' RECV EEROE CMD='cm' SNS=' sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbcchh' I BLOCK=' nnnnnn '} ] DMKDAS5201 type 'addr' CHAN ERROR CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IBLOCK=' nnnnnn'}] DMKDAS5361 cuu REPORTS DISABLED INTERFACE; FAULT CODE = cccc; NOTIFY CE DMKDAS956A DASD cuu VOLID volid NCT MCONTED; NOW OFFLINE DMKDAU5331 DMKDAU5341 DMKDAU5351 DMKDAU536I DASD 'addr' DASD 'addr' DASD 'addr' cuu REPORTS DMKDDR038E DSKDDR536I DMKDDR100E DMKDDR101E DMKDDR102E DMKDDE703E DMKDDR104E DMKDDR105E DMKDDR101E DMKDDR108E DMKDDR109E DMKDDR1l0A DMKDDR111R DMKDDR1l2E DMKDDR1l3E DMKDDR114E DMKDDR1l5E DMKDDB116R DMKDDR1l1R DMKDDR126E DMKDDR121E DMKDDR1291 DMKDDR756E PARAMETER parameter FCR option CPTION MISSING OR INVALID cuu REPORTS DISABLED INTERFACE; FAOLT CODE = cccc; NOTIFY CE INPUT UNIT IS NOT A CFVOL INVALID OPERAND - operand CONTROL STATEMENT SEQUENCE EREOE OPERAND MISSING DEV CUll NOT OPERATICNAL 10 ERROR cuu CSW='csw' SENSE='sense' INPUT={'bbcchh'I'nnnnnn'} OUTPUT='bbcchh' CCW='ccw' MACHINE CHECK RUN SEREF AND SAVE OUTPUT FOR CE INVALID INPUT OR OUTFUT DEFINITION WRONG INPUT TAPE MOUNTED DEV cuu INTERVENTICN EECUIRED VOLID READ IS volid2 [NOT volidl] DO YOU WISH TO CONTINUE? RESPOND YES NO OR REREAD: NOMBER OF EXTENTS EXCEEDS 20 OVERLAPPING OR INVALlt EXTENTS RECORD {bbcchhlnnnnnn) NO~ FOUND ON ~APE LOCATION bbcchh IS A FLAGGED TRACK NO VOLl LABEL FOUND [FOR volserJ DO YOU WISH TO CONTINUE? RESPOND YES OR NO OR REREAD: DATA DUMPED FROM volidl TC BE BESTOREt TO volid2. DO YOU WISH TO CONTIN.UE? RESPOND YES NO OR REREAD: OUTPUT UNIT IS FILE PROTECTED INVALID FILE NAME OR FILE NOT FOUND ERROR IN routine RECORD cchhr NOT FOUND RECORD {cchhrlnnnnnn} NOT FOUND OUTPUT UNIT NOT PROPERLY FORMATTED FOR THE CP NUCLEUS NO VALID CP NUCLEUS CN THE INPUT UNIT INPUT TAPE CONTAINS A CP NUCLEUS DUMP ORIGINAL INPUT DEVICE WAS (IS) lARGER THAN OUTPUT DEVICE. DO IOU WISH TO CONTINUE? RESPOND YES OR NO: MOVING DATA INTO THE ALTERNATE TRACK CYLINDER(S) IS PROHIBITED FLAGGED TRK xxxxxxxxxx HAS NO PROPER ALTERNATE; SKIPPING THIS TRK FULL TRACK REAt FEATURE NCT AVAILABLE PROGRAM CHECK PSW = psw DMKDEF003E DMKDEF022E DMKDEF024E DMKDEF025E DMKDEF026E DMKDEF040E DMKDEF091E DMKDEF094E DMKDEF095E DMKDEF136E DMKDEF153E DMKDEF2581 DMKDEF259E INVALID OPTION - option VADDR MISSING OR INVALID {CYLSIBLKSIFORM NUMEER} MISSING OR INVALID STORAGE MISSING OR INVALlt OPERAND MISSING OR INVALID DEV addr DOES NOT EXIST DASD vaddr NOT DEFINED; TEMP SPACE NO'1 AVAILABLE STORAGE EXCEEDS AILCWED MAXIMUM DEV vaddr NOT DEFINED; INSUFFICIENT PBEE STORAGE DEVICE {vaddrlraddr} NOT {DEFINEDIVARIED}; CHANNEL XX DEPICATED DEVICE (vaddrIRNG} EXCEEDED MAX NUMBER OF VIRTUAL DEVICES ALL 3800 DATA CHECKS WILL EE REFLECTED SIZE PARAMETER MISSING OR INVALID DMKDEB025E DMKDEB026E DMKDEB092E DMKDEH09QE STORAGE MISSING OR INVALID OPERAND MISSING OR INVALID DEV vaddr NOT DEFINED; type vaddr ALREADY DEFINED STORAGE EXCEEDS AIICWED MAXIMUM DMKDDR1l8E DMKDDR119E DMKDDR120E DMKDDB121E DMKDDR121E DMKDDR122E DMKDDR123E DMKDDE124E DMKDDR125R CHECK DATA CMD='cm' SNS='sense' CSW='csw' USERID='userid' BLOCK='nnnnn»' BKSIZE EX CMD='cm' SNS='sense' CSW='csw' USERID='userid' BLOCK='nnnnnn' WRT INHIEIT CMD='cm' SNS='sense' CSW='csw' USERID='userid' BLOCK='nnnnnn' DISABLED INTERFACE; FAULT CODE = cccc; NOTIFY CE DMKDEI009E INVALID RANGE - range DMKDEI021E BADDR MISSING OR INVALID DMKDEI026E OPERAND MISSING OR INVALID 288 IBM VM/SP System Messages and Codes DMK DMKDEI046E DMKDEI075E DMKDEl143E DMKDEI274E DMKDEI275E DMKDEI276E DMKDEI277E DMKDEI278E DMKDEI279E DMKDEI280E {DEV ridltype raddr} OFFLINE DEVICE 'raddr' IS NOT AVAIIAElE type raddr IN USE BY SYSTEM raddr HAS A MOUNTED VOLUME. !SS ID NOT AVAILAEIE TO DEMOUNT IT raddr ALREADY SYSVIRT raddr NOT 3330V raddr ERROR DEMOUNTING VOLUME DEVICE NOT A DASD DASD NOT VUA raddr ALREADY VIRtUAL DMKDIA011E DMKDIA017E DMKDIA020E DMKDIA022E DMKDIA045E DMKDIA047E DMKDIA055E DMKDIA056E DMKDIA098E DMKDIA199E DMKDIA206E DMKDIA707A INVALID DEVICE TYPE - userid vaadr INSUFFICIENT SCREEN SPACE - CLEAR SCREEN AND REDIAL USERID MISSING OR INVALID VADDR MISSING OR INVALID userid NOT LOGGED ON userid vaddr DOES NOt EXIS~ LINE(S) NOT AVAIIAElE CN userid LINE vaddr BUSY ON userid DEV rid MODE SWItCH NO~ POSSIELE COMMAND REJECTED; DEVICE raddr PENDING OF~INE CANNOT CONNECT TO HOST VIRtUAL MACHINE DIAL FUNCTION NOT AVAILABLE DMKDIE006E DMKDIE011E DMKDIE020E DMKDIB022E DMKDIE040E DMKDIB045E DMKDIB047E DMKDIE058E INVALID DEVICE TYPE - vaddr INVALID DEVICE TYPE - userid vaddr USERID MISSING OR INVALID VADDR MISSING OR INVALID DEV addr DOES NOT EXIST userid NOT LOGGED ON userid vaddr DOES NOT EXIST CTCA vaddr BUSY CN userid DMKDIR536I DMKDIR751E DMKDIR752E DMKDIR753E DMKDIR754E DMKDIR755E DMKDIR756E DMKDIR757E DMKDIR758E DMKDIR760E DMKDIR761E DMKDIE762E DMKDIR763E DMKDIB764E cuu REPORTS DISABLED INTERFACE; FAULT CODE = eccc; NOTIFY CE INVALID OPERAND - oFerand STATEMENT SEQUENCE ERRCR FOILCWING USER user OPERAND MISSING DEV cuu NOT OPERATICNAL 10 ERROR cuu CSW='csw' SENSE='sense' PROGRAM CHECK PSi = psw MACHINE CHECK RUN SEREP AND SAVE OUTPUT FOR CE DUPLICATE UNIT DEFINITION NOT ENOUGH SPACE ALLOCATED FOR DIRECTORY VOLID READ IS volid1 NOT volid2 (ON cuu) DIRECTORY STATEMENT MISSING INVALID FILENAME OR FIlE NeT FOUND ERROR IN routinE DMKDMP5361 DMKDMP905W DMKDMP906W DMKDMP907W DMKDMP9081 DMKDMF909W DMKDMP9131 DMKDMP9181 cuu REPORTS DISABLED INTERFACE; FAULT CODE = eccc; NOTIFY CE SYSTEM DUMP FAILURE; PROGRAM CHECK SYSTEM DUMP FAILURE; MACHINE CHECK, RUN SEREP SYSTEM DUMP FAILURE; FATAL l/C ERROR SYSTEM FAILURE; CODE - code SYSTEM DUMP DEVICE NOT-READY CP OWNED VOLID xxxxxx INVALID FCR 3330V SYSTEM DUMP FAILURE; STATUS NOT STORED FOR NON-ABENDING PROCESSOR DMKDRD9251 SYSTEM AUTO DUMP REAIICCATED to DASD raddr DMKDSB956A DASD cuu VOLID volid NOT MOUNTED; NOW OFFLINE DMKDSP450i CP ENTERED; DISABLED WAIT PSi 'psw' DMKDSP452W CP ENTERED; EXTERNAL INTERRUPt LOOP DMKFMT5361 DMKFMT730E DMKFMT732E DMKFMT733E DMKFMT734E DMKFMT735E DMKFMT736E DMKFMT737E DMKFMT738A = cuu REPORTS DISABLED INTERFAC!; FAULT CODE eccc; NOTIFY CE DEV cuu NOT OPERATIONAL OR NOT READY MACHINE CHECK RUN SEREP AND SAVE OUTPUT FOR CE VOLID READ IS volid1 NOT volid2 TYPE OR {CYLIPAG} INVALID FATAL DASD 10 ERROR 10 ERROR cuu {CCHBR=cchhrIBLOCK=nnnnnn} SENSE='sense' INVALID OPERAND DEV cuu INTERVENTION REQUIRED Appendix B. Message Summary Alphamerically by Message Identifier 289 DMK DMKFMT739E FLAGGED PRIMARY TRACK HAS NO AL~ERNATE ASSIGNED;IO ERROR FOLLOWS DMKFMT740E PACK MOUNTED IS 3340-35, NOT 3340-70. MOUNT ANOTHER OR RESPECIFY DMKFMT756E PROGRAM CHECK PSW = psw DMKGRF457E TERHINAL SCRNSAVE UNSUCCESSFUL DMKGRF5001 type 'addr' CMD REJECT CMD='cm' SNS='sense' CSW='qsw' USERID='userid' [ {BBCCHH='bbcchh'IBICCK='nnnnnn'}] DMKGRF502I type 'addr' BUSOU~ CK CMD='CH' SNS='SENSE' CSW='csw' USERID='userid' [{BBCCHH='BBCCHH'IBLOCK='nnnnnn'} ] DMKGRF5031 type 'addr' EQUIP CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IBLOCK='nnnnnn'}] DMKGRFS041 type 'addr' DATA CK CMD='cm' SNS='sense' CSW='csw' USERID= 'userid' [ {BBCCHH='bbcchh'IBLOCK='nnnnnn'}] DMKGRF5211 type 'addr' NO DEVICE CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKGRF525I {GRFIRDRIPRTIPUN} 'addr' FORHAT CK CMD='cm' SNS='sense' USERID='userid' DHKGRF5291 {GRAFIRDRIPRTIPUN} 'addr' PARIIY CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKGRF530I GRAF 'addr' UNIT SPEC CMD='cm' SNS='sense' USERID='userid' DMKGRF531I GRAF 'addr' CNTRL CHECK CMD='cm' SNS='sense' USERID='userid' DHKGRF532I GRAF 'addr' OP CHECK CMD='cm' SNS='sense' USERID='userid' DMKIOB724I {APIMP} RIOBLOCKS REQUESTED IN UNIPROCESSOR DUMP DMKIOF550E ERROR RECORDING AREA 90 PERCENT FULL; RUN CPEREP DMKIOG551E DHKIOG5521 DMKIOG5531 DMKIOG558I ERROR RECORDING AREA FULL; RUN CPEREP. FORMATTING ERROR RECORDING AREA ERROR RECORDING AREA CLEARED; USER 'userid' UNRECOVERABLE I/O ERROR; ERROR RECORDING DISABLED DMKIOH559W SRF cuu NOT ACCESSIEIE; FRAMES NOT ON ERROR CYLINDERS DHKICH560W ERRORS ON SRF cuu: FRAMES NOI ON ERROR CYLINDERS DHKIOH561W MORE THAN 50 MCH CR CCH FRAMES WERE READ FROH SRF cuu DMKLD09231 FAILING STORAGE FRAHE AT LOCAIICN raddr DMKLD0924I xxxx ADDITIONAL FAILING SIORAGE FRAHES EXIST DHKJRL1451 USERID:userid AT term-raddr WItH INVALID {LINKILOGON} PASSWORD NO.xxx (pswd) HAS VIOLAIED IHE LIMII CF yyy [,A=auserid] DHKLNK02QE DMKLNK022E DMKLNK052E DMKLNK053E DMKLNK101W DHKLNK102W DHKLNK103W DMKLNK104E DMKLNK105E DMKLNK106E DMKLNK107E DMKLNK108E DMKLNK109E DHKLNK110E DMKLNK111E DHKLNK112E DMKLNK113E DHKLNK114E DMKLNK115E DMKLNK116E DMKLNK117E DMKLNK118E DMKLNK119E DMKLNK137E DHKLNK139E DMKLNK153E DMKLNK199E USERID MISSING OR INVALID VADDR MISSING OR INVALID ERROR IN CP DIRECTORY userid NOT IN CP DIREC~ORY DASD vaddr FORCED R/C; R/C EY {nnn USERSluserid} DASD vaddr FORCED RIO; R/W EY {nnn USERSluserid} DASD vaddr FORCED RIO; R/i BY {nnn USERSluserid}; RIO BY {nnn USERSluserid} userid vaddr NOT lINKED; R/O EY {nnn USERSluserid} userid vaddr NOT LINKED; R/W EY {nnn USERSluserid} userid vaddr NOT lINKED; R/W EY nnn USERS; R/O BY {nnn USERSluserid} userid vaddr NOT lINKED; NOT IN CP DIRECTORY userid vaddr NOT LINKED; VOLID volid NOT MOUNTED userid vaddr NOT LINKED; INVALID LINK DEVICE userid vaddr NOT lINKED; type vaddr ALREADY DEFINED userid vaddr NOT LINKED; NO READ PASSWORD userid vaddr NOT LINKED; NO WRITE PASSWORD userid vaddr NOT LINKED; NO MUll PASSWORD userid vaddr NOT LINKED; PASSWORD INCORRECT LINK INVALID; EXCESSIVE INCORRECT PASSWORDS USERID xxx NOI LINKED; CP DIRECTORY IN USE USERID userid NOT LINKED; VOLID volid CONFLICT userid vaddr NOT LINKED; COHMAND FORMAT NOT VALID USERID vaddr NOT LINKED; INSUFFICIENT FREE STORAGE DASD vaddr NOT LINKED; CHAN x DEDICATED DASD raddr NOT {LINKEDIATTACHED}; 3330V NOT ACCEPTED AS SYSTEM VOLUftE DEVICE {vaddrIRNG} EXCEEDED MAX NUMBER OF VIRTUAL DEVICES COMMAND REJECTED; DEVICE raddr PENDING OFFLINE DMKLOG003E DMKLOG020E DHKLOG050E DMKLOG052E DMKLOG053E DMKLOG054E INVALID OPTION ~ option USERID MISSING OR INVALID PASSWORD INCORRECT. REINITIATE LOGON PROCEDURE ERROR IN CP DIRECTORY userid NOT IN CP DIREC~ORl ALREADY LOGGED ON {LINEIGRAFIIUNAME} raddr 290 IBH VM/SP System Messages and Codes DMK DMKLOG067E DMKLOG080E DMKLOG081W DMKLCG082E DMKLOG090E DMKLOG091E DMKLOG092E DMKLOG093E DMKLOG095E DMKLOG131E DMKLOG188E DMKLOG189I DMKLOG250E DMKLOG251E COMMAND FORMAT NOT VALID NO P~EALLOCATED VMSAVE AREA VMSAVE AREA ALREADY IN USE, MUS~ USE SET COMMAND MORE THAN ONE VMS AVE AREA ALLOCATED, MUST SPECIFY AREA NAME DEV vaddr NOT DEFINED; DEV {raddrlvolser} NOT AVAILABLE DASD vaddr NOT DEFINED; TEMP SPACE NOT AVAILAELE DEV vaddr NOT DEFINED; type vaddr ALREADY DEFINED DEV vaddr NOT DEFINED; ERROR IN CP DIRECTORY DEV vaddr NOT DEFINED; INSUFFICIENT FREE STORAGE INSUFFICIENT FREE STORAGE AVAILABLE FCR {ATTACHILOGON} REQUEST SPECIFIED PROCESSOR UNAVAILABLE AFFINITY NOT SET; SjS~EM IN UNIPROCESSOR MODE 370E IS NOT AVAILAEIE (CN PROC xx) 370E IS NOT ACTIVE DMKLOH196E SECONDARY USER NOT IN CP EIRECTORY DMKLOH206E CANNOT CONNECT TO HOS~ VIRTUAL MACHINE DMKMCC002E DMKMCC003E DMKMCC006E DMKMCC021E DMKMCC026E DMKMCC040E DMKMCC046E DMKMCC140E DMKMCC143E DMKMCC199E DMKMCC211E DMKMCC213E DMKMCC215E DMKMCC216E DMKMCC217E DMKMCC221E INVALID OPERANE - operand INVALID OPTION - option INVALID DEVICE TYPE - addr RADDR MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIS~ {DE V ridltype raddr} CFFLINE type raddr ATTACHED TO userid type raddr IN USE EY SYSTEM COMMAND REJECTED; DEVICE raddr PENDING OFFLINE MONITOR TAPE IS ALREADY ACTIVE MONITOR CPTRACE IS ALREADY ACTIVE MONITOR ACTIVE; DASTAF CANNOT BE ENAELED DYNAMICALLY SYSPROF CLASS IS DEPENDENT ON SCHEDULE AND DASTAP MONITOR TAPE NOT STARTED, NO CLASS ENAELED MONITOR TO SPOOL IS ALREADY ACTIVE DMKMCD002E DMKMCD021E DMKMCD026E DMKMCD040E DMKMCD212E DMKMCt214E DMKMCD218E PMKMCD222E DMKMCD223E DMKMCD224E DMKMCD226E DMKMCD227E DMKMCD228E INVALID OPERAND - operand RADDR MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIST MONITOR TAPE IS NOT ACTIVE MONITOR CPTRACE IS NOT ACTIVE MONITOR NOT STOPPED, OUTS'IANDING I/O TIME PARAMETER SPECIFIES INVALID TIME START TIME MUST PRECEDE STOP TIME LIMIT MUST BE EETWEEN 10 and 50000 FOR VALUE MIDNIGHT - CCMMAND INVALID FOR OPTION INVALID WITH AUTODISK OFF FOR OPTION INVALID WITH MCNITCR ON DMKMCH610W DMKMCH611W DMKMCH612W DMKMCH6131 DMKMCH614I DMKMCH6151 DMKMCH616I DMKMCH6171 DMKMCH609W DMKMCH619I DMKMCH622W DMKMCH624I MACHINE CHECK; SUPERVISOR DAMAGE cpuid MACHINE CHECK; SYSTEM INTEGRITY LOST cpuid MACHINE CHECK; TIMING FACILITIES DAMAGE; RUN SEREP cpuid SOFT MACHINE CHECK BECORDING DISABLED cpuid MACHINE CHECK; DAMAGED PAGE NOW DELETED cpuid MACHINE CHECK BECOBDING FAILURE cpuid MACHINE CHECK; USER userid TERMINATED cpuid MACHINE CHECK; EUFFEB CR DLAT EAMAGE cpuid MACHINE CHECK; PROCESSOR CONTBOLLER DAMAGE cpuid MACHINE CHECK; OPERATION TERMINATED cpuid MACHINE CHECK; MULTIPLE CHANNEL ERRORS MACHINE CHECK; EXTEBNAL DAMAGE DMKMCI003E INVALID OPTION - option DMKMCI026E OPERAND MISSING OR INVALID DMKMCI618I {INSTRUCTION RETRYIMAIN STORAGE} NOW IN {RECORDIQUIET} MODE cpuid DMKMCT610W DMKMCT611W DMKMCT612W DMKMCT6161 DMKMCT6191 DMKMCT6201 DMKMCT6211 MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; SUPERVISOR DAMAGE cpuid SYSTEM INTEGRITY LOST cpuid TIMING FACILITIES DAMAGE; BUN SEREP cpuid USER userid TERMINATED cpuid OPERATION TERMINATED cpuid ATTACHED PROCESSOR NOT BEING USED AFFINITY SET OFF Appendix B. Message Summary Alphamerically by Message Identifier 291 DMK DMKMCT623I CHANNEL SET CONNECTED !O ATTACHED PROCESSOR nn DMKMCT625I ALTERNATE PROCESSOR RECOVERY SUCCESSFUL; PROCESSOR nn OFFLINE DMKMIA229E MONITOR OUT OF EASD PAGES, IS SHUTTING OFF DMKMID310E DATE date INVALID; NO~ CHANGED DMKMNI002E INVALID OPERANt - operand DMKMNI225E INVALID MONITOR USERID SPECIFIED, MON NOT ENABLED DMKMON219I END OF MONITOR TAPE, MONITOR STCPPED EY SYSTEM DMKMCN2201 ERROR ON MONI~OR !APE, MONI~OR STOPPED BY SYSTEM DMKMSG003E DMKMSG020E DMKMSG045E DMKMSG057W INVALID OPTION - option USERID MISSING OR INVALID userid NOT LOGGED ON userid NOT RECEIVING; {DISCONNECTEDIMSG OFFISMSG OFFINOT DISCINO CONSOLEINOT AUTHORIZEDIWNG OFFIV~CF/IUCV EREOR nnn} DMKNEA002E DMKNEA006E DMKNEA020E DMKNEA026E DMKNEA040E DMKNEA046E DMKNEA120E DMKNEA121E DMKNEA122E DMKNEA208E INVALID OPERAND - o~erand INVALID DEVICE TYPE - addr USERID MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EXIST {DEV ridltype raddr} OFFLINE [PRT ridltype raddr] NOT ATTACHED; userid vaddr ALREADY DEFINED [PRT ridltype raddr] NOT ATTACHED TO userid [PRT ridltype raddr] ALREADY ATTACHED TO userid PRT rid NOT ENABLED DMKNES002E DMKNES004E DMKNES006E DMKNES009E DMKNES021E DMKNES026E DMKNES040E DMKNES046E DMKNES049E DMKNES098E DMKNES140E DMKNES160E DMKNES175E DMKNES199E DMKNES706E INVALID OPERAND - o~erand INVALID HEXLOC - hexlcc INVALID DEVICE TYPE - addr INVALID RANGE - range RADDR MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NO! EXIS! {DEV ridltype raddr} CFFLINE LINE addr IN USE DEV rid MODE SWITCH NCT PCSSIELE type raddr ATTACHED TO userid HEXLOC hexloc EXCEEDS STOEAGE {FAVOREDIRESERVElname} ALREADY IN USE BY userid COMMAND REJECTED; DEVICE raddr FENDING OFFLINE LINE addr NOT ENABLEE DMKNET002E DMKNET003E DMKNET004E DMKNET006E DMKNET009E DMKNET021E DMKNET026E DMKNET033E DMKNET040E DMKNET046E DMKNET049E DMKNET098E DMKNET140E DMKNET160E DMKNET199E INVALID OPERAND - o~erand INVALID OPTION - option INVALID HEXLOC - hexloc INVALID DEVICE TYPE - addr INVALID RANGE - range RADDR MISSING OR INVALID OPERAND MISSING OR INVALID HEXLOC MISSING OR INVALID DEV addr DOES NOT EXIST {DEV ridltype raddr} OFFLINE LINE addr IN USE DEV rid MODE SWITCH NOT POSSIBLE type raddr ATTACHED TC userid HEXLOC hexloc EXCEEES STORAGE COMMAND REJECTED; DEVICE raddr PENDING OFFLINE DMKNLD002E DMKNLD006E DMKNLD021E DMKNLD026E DMKNLt040E DMKNLD044E DMKNLD046E DMKNLD140E DMKNLD143E DMKNLD170E DMKNLD171E INVALID OPERAND - ofErand INVALID DEVICE TYPE - addr RADDR MISSING OR INVALID OPERAND MISSING OR INVALID DEV addr DOES NOT EllS! SYSTEM name DOES NOT EXIST {DEV ridltype raddr} OFFLINE type raddr ATTACHED TO userid type raddr IN USE BY SYSTEM SYSTEM name EXCEEDS STCRAGE SYSTEM name VOLID valid NOT MCUNTED 292 IBM VM/SP System Messages and Codes DMK DMKNLD199E DMKNLD460E DMKNLD461R DMKNLD470E DMKNLD471E COMMAND REJECTED; DEVICE raddr PENDING OFFLINE CTLR raddr {LOADIDUMP} FAILED: PROGRAM CHECK CTLR raddr IPL NOT REQUIRED; ENTER 'YES' TO CONTINUE CTLR raddr {LOADIDUMP} FAILEt: PAGING I/O ERROR CTLR raddr LOAD FAILED: UNRECOVERABLE I/O ERROR DMKNLE003E DMKNLE006E DMKNLE021E DMKNLE040E DMKNLE046E DMKNLE140E DMKNLE143E DMKNLE199E DMKNLE460E DMKNLE461R DMKNLE4641 DMKNLE469E DMKNLE470E DMKNLE471E INVALID OPTION - option INVALID DEVICE TYPE - addr RADDR MISSING OR INVALID DEV addr DOES NOT EXIST {DEV ridltype raddr} CFFLINE type raddr ATTACHED TO userid type raddr IN USE BY SYSTEM COMMAND REJECTED; DEVICE raddr PENDING OFFLINE CTLR raddr {LOADIDUMP} FAILED: PROGRAM CHECK CTLR raddr IPL NOT REQUIRED; ENTER "YES" TO CONTINUE CTLR raddr CC=3; DEPRESS 370X "lOAD" EUTTON CTLR raddr {LOADIDUMP} FAILED: TEMP SPACE NOT AVAILABLE CTLR raddr {LOADIDUMP} FAIlEt: PAGING I/O ERROR CTLR raddr DUMP FAILED: UNRECOVERABLE 1/0 ERROE DMKNMT2471 DMKNMT248E DMKNMT249E DMKNMT254E DMKNMT256E DMKNMT257E 3800 NAMED SYSTEM imag3800 CREATED SPECIFIED IMAGE imag NCN-EXISTENT ERROR LOADING IMAG imag ERROR SAVING imag3800 - RC = (rc) INSUFFICIENT VIRTUAL STORAGE RESIDUAL BYTE COUNT = nnnnnnnn (HEX) DMKPAH415E CONTINUOUS PAGING ERRORS FROM DASD xxx DMKPGT4001 SYSTEM {TEMP SPACEICHECKPCINT AREA} FULL DMKPGT4011 SYSTEM {TEMP SPACEICEECKPOINT AREA} 90 PERCENT FULL DMKPRG411W CP ENTERED; TRANSLATION EXCEPTICN WHILE IN NON-EC MODE DMKPRG453W CP ENTERED; PROGRAM INTERRUPT LOOP DMKPTR410W CP ENTERED; PAGING ERROR DMKQCN150A USER userid HAS ISSUED A {CPIVM} READ DMKQVM020E DMKQVM800E DMKCVM801E DMKQVM802E DMKQVM803E DMKQVM806E DMKQVM807E DMKQVM809E USERID MISSING OR COMMAND REJECTED, FREE STORAGE PAGE COMMAND REJECTED, COMMAND REJECTED, COMMAND REJECTED, COMMAND REJECTED, COMMAND REJECTED, INVALID OTHER VIRTUAL MACHINES LOGGED ON IS NOT AVAILAELE DEVICES NOT DEDICATED SPOOL DEVICES NOT DRAINED VIRTUAL ADDEESS NOT EQUAL TO REAL ADDRESS VM/SP ATTACHED PROCESSOR MODE TRACE/ACSTOP/CCW TRANS IN EFFECT DMKRGA4541 {LINE addrlDEV rid} DISABLED DMKRGA4551 LINE 'addr' NOT OPERATIONAL; text DMKRGA7051 I/O ERROR RESlt=resource id STATUS=status LINE=addr DMKRND8501 DMKRND8511 DMKRND8521 DMKRND853I DMKRND861E DMKRND863E DMKRNDB641 UNABLE TO READ DUMP FEOM READER TEN DUMP FILES ALREADY EXIST FATAL I/O ERROR WRITING DUMP NO DUMP FILES EXIST DUMP FILE 'filename' NOT FOUND INVALID PARAMETER _ parameter PAGE REFERENCED NOT AVAILABLE WHILE EDITING xxxxxxxx DMKRNH4541 DMKRNH4621 DMKRNH4631 DMKRNH4641 DHKRNH4681 {LINE addrlDEV rid} tISABLED CTLR raddr UNIT CHECK; IPL REQUIRED CTLR 'raddr' UNIT CHECR; RESTART IN PROGRESS CTLR raddr CC=3; DEPRESS 370X "LOAD" BUTTON CTLR cuu COMMUNICATIONS SCANNEE FAILUEE DMKRSE240E DHKRSE241E DMKRSE242E DMKRSE2521 DMKRSE2551 DMKRSE5001 PRT cuu, FCB-FORMS MISMATCH, FILEID nnnn {HELDIPURGED} PRT cuu, INVALID LOAD MODULE mmmm SPECIFIED, FILE nnnn {HELDIPURGED} PRT cuu (3800) INTERVENTION RECQD, STATUS CODE cc PRT cuu, FILE nnnn REQUEUED AND HELD PRT cuu, PAGE EUFFER DESTROYED, BACKUP PAGE COUNT = nnnn type 'addr' CMD REJECT CMD='cm' SNS='sense' CSW='csw' USERID='userid' Appendix B. Message Summary Alphamerically by Message Identifier 293 DMK [ {BBCCHH='bbcchh'IBLOCK='nnnnnn'}] DMKRSE501A type 'addr' INT REQ CMD='cm' SNS=Qsense' CSW='csw' USERID=' userid' [ {BBCCHH='bbcchh'IBICCK='nnnnnn'}] DMKRSE5011 {CONIPRTIPUNIRDR} 'addr' INT REQ [CMD='cm' SNS='sense' CSW='csw'USERID='userid'] DMKRSE5021 type 'addr' BUSOUT CK CMD='CM' SNS='SENSE' CSW='csw' USERID='userid' [ {BBCCHH='BBCCHH'JBLOCK='nnnnnn'}] DMKRSE503A {RDRIPRTIPUN} 'addr' EQUIP CK CMD='cm' SNS='sense' DMKRSE5031 type 'addr' EQUIP CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IBLOCK='nnnnnn'}] DMKRSE504A {RDRIPRT} 'addr' DATA CK CMD='cm' SNS='sense' DMKRSE5041 type 'addr' DATA CK CMD='cm' SNS='sense' CSW='csw' USERID= 'userid' [ {BBCCHH='bbcchh'JBLOCK='nnnnnn'}] DMKRSE505A RDR 'addr' OVERRUN CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKRSE5081 {DASDIRDRIPRTIPUN} 'addr' PERM ERROR CMD='cm' SNS='sense' CSW='csw' USERID='userid' [BBCCHH='bbcchh'] DMKRSE520A {RDRIPRTIPUN} 'addr' PERM ERROR CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKRSE5201 type 'addr' CHAN ERRCE CMI='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IBLCCK='nnnnnn'}] DMKRSE5211 type 'addr' NO DEVICE CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKRSE5241 {RDRIPRTIPUN} 'addr' lCAD CHECK CMD='cm' SNS='sense' USERID='userid' DMKRSE5251 {GRFIRDRIPRTIPUN} 'addr' FORMA7 CK CMD='cm' SNS='sense' USERID='userid' DMKRSE5291 {GRAFIRDRIPRTIPUN} 'addr' PARI7Y CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKRSP426E DMKRSP428E DMKRSP431A DMKRSP432A DMKRSP433A DMKRSP434A {RDRITAPE} radar SPCOl SPACE FULL; FILE PURGED {PRTIPUNIRDRITAPE} raddr SPOOL ERRORi FILE {HELDIPURGED} RDR raddr ID CARD MISSING OR INVALID RDR raddr ID CARD; 'userid' NOl IN CP DIRECTORY RDR raddr ID CARDi INVALID DATA - 'data' RDR raddr FATAL I/O ERROR; FILE PURGED DMKSAV350W DMKSAV351W DMKSAV352W DMKSAV353W DMKSAV5361 DASD raddr SYSRES VCIID NOT aaaaaa DASD raddr SYSRES NO! READY FATAL DASD I/C ERROR SYSRES DEVICE TYPE INVALID cuu REPORTS DISABLED INTERFACE; FAULT CODE DMKSNC044E DMKSNC171E DMKSNC178E DMKSNC179E DMKSNC435E SYSTEM SYSTEM SYSTEM SYSTEM PAGING cccc; NOTIFY CE name DOES N07 EXIS7 name VGIID volid NCT MCUNTED name EXCEEDS AVAILABLE DASD SPACE name VOLID volid NCT CF CWNED ERROR WRITING SAVED SYSTEM DMKSND020E USERID MISSING OR INVALID DMKSND045E userid NOT LOGGED ON DMKSND068E SEND COMMAND FAILED - RECEIVER {IS NOT DISCONNECTEDIHAS NOT AUTHORIZED SENDEBIHAS NO VIRTUAL CONSOLEICONSOLE INPUT WAITING lIS EXECUTING A CONSOLE FUNCTION} DMKSPM026E DMKSPM804E DMKSPM805E DMKSPM8081 OPERAND MISSING OR INVALII SINGLE PROCESSOR MODE ON REaEC!ED SINGLE PROCESSCR MODE CFF REJECTED SINGLE PROCESSOR MODE ACTIVE DMKSPS014E DMKSPS026E DMKSPS026E DMKSPS028E DMKSPS037E DMKSPS426E DMKSPS428E TAPE raddr DUMF TAPE CAPACITY EXCEEDED OPERAND MISSING OR INVALID OPERAND MISSING OR INVALID CLASS MISSING OR INVALID TAPE raddr INVALID FCR SPTAPE CCMMAND {RDRITAPE} raddr SPOOL SPACE FULLi FILE PURGED {PRTIPUNIRDRITAPE} raddr SPCOI ERROR; FILE {HELDIPURGED} DMKSPT002E DMKSPT003E DMKSPT006E DMKSPT008E DMKSPT021E DMKSPT024E DMKSPT040E DMKSPT046E DMKSPT140E DMKSPT143E DMKSPT199E INVALID OPERAND - oFerand INVALID OPTION - option INVALID DEVICE TYPE - addr INVALID SPOOLID - spoolid RADDR MISSING OR INVALID {CYLSIBLKSIFORM NUMBER} MISSING OR INVALID DEV addr DOES NOT EXIST {DEV ridltype raddr} GFFLINE type raddr ATTACHED TO userid type raddr IN USE BY SYSTEM COMMAND REaECTED; DEVICE raddr PENDING OFFLINE 294 IBM VM/SP System Messages and Codes , DMK DMKSSP5361 cuu REPORTS DISABLED INTERFACE; FAULT CODE = cccc; NOTIFY CE DMKSSS070E DMKSSS071E DMKSSS072E DMKSSS074E DMKSSS075E DMKSSS0781 DEVICE NOT AVAILAELE - MSS DEVICES ALLOCATED DEVICE NOT AVAILAELE - MSS CANNCT BE ACCESSED DEVICE NOT AVAILAELE - 'raddr' NO~ PROPER TYPE MISSING INTERRUPT - DEVICE 'raddr' DEVICE 'raddr' IS NOT AVAILAELE MSS MOUNT PROCEEDING FCR VOLU~E 'volid' DMKTAP5001 type 'addr' CMD REJECT CMD='cm' SNS='sense' CSi='csw' USERID='userid' [ {BBCCHH='bbcchh'IBLCCK='nnnnnn'}] DMKTAP501A type 'addr' INT REQ CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IBLOCK='nnnnnn'}] DMKTAP5021 type 'addr' BUSOUT CK CMD='CM' SNS='SENSE' CSW='csw' USERID='userid' [ {BBCCHH=' BBCCHH' I BLOCK=' nnnnnn '} ] DMKTAP5031 type 'addr' EQUIP CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IBLOCK='nnnnnn'}] DMKTAP504D {DASDITAPE} 'addr' DATA CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' {BBCCHH='bbcchh'} DMKTAP505D {DASDITAPE} 'addr' OVERRUN CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbcchh ' I BLCCK=' DnDnnn '} ] DMKTAP5101 TAPE 'addr' CONVERT CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKTAP5111 TAPE 'addr' COMPA! CK CMD='cm' SNS='sense' CSi='csw' USERID='userid DMKTAP5121 TAPE 'addr' LCAD POINT CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKTAP5161 type 'addr' BAD SENSE CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IEICC~='nnnnnn'}] DMKTAP5171 {LINEITAPE} 'addr' NOT/KNOWN CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKTAP5181 {DASDITAPE{ 'addr' RECV ERROR CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IBICCK='nnnnnn')] DlI!KTAP5191 TAPE 'addr' PE BURS! CMD='cm' SNS='sense' CSW='csw' USERID='userid' DlI!KTAP5201 type 'addr' CHAN ERRCR CMt='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbcchh' I BLOCK=' DnnnDD'} ] DMKTAP5211 type 'addr' NO DEVICE CMD='cm' SNS='sense' CS~='csw' USERID='userid' DMKTAP5221 TAPE 'addr' ERASE CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKTAP5231 TAPE 'addr' CONTROL CK ClI!D='cm' SNS='sense' CSW='csw' USERID='userid' DMKTAP5261 TAPE 'addr' DSE FAI1~I CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKTCS240E PRT cuu, FCB-FORMS ~ISMATCH, FIIEID nnnn {HELDIPURGED) DMKTCS241E PRT cuu, INVALID LOAD MODULE mmmm SPECIFIED, lILE nnnn {HELDIPURGED} DMKTCT270E PRT xxx, TOO MANY WCGM'S NEEDED FOR 'CHARS', FILE nnnn HELD PURGED DMKTHI002E DMKTHI003E DMKTHI026E DMKTHI045E INVALID OPERAND - oFErand INVALID OPTION - option OPERAND MISSING OR INVALID userid NOT LOGGED ON DMKTRA002E DlI!KTRA003E DMKTRA013E DMKTRA026E DMKTRA180W DMKTRA182E INVALID OPERAND ~ oFerand INVALID OPTION - option CONFLICTING OPTION - option OPERAND MISSING OR INVALID TRACE NOT IN EFFECT (reserved for IBM use) DMKTTR042E SPOOLID nnnn DOES NOT EXIST [OR IS HELD] DMKTTY152E {PFCOPYIPFTAB} NOT AVAILAEIE DMKTRP002E DMKTRP005E DMKTRP013E DMKTRP020E DMKTRP026E DMKTRP045E DMKTRP304I DMKTRP3051 DMKTRP306E DMKTRP309E INVALID OPERAND - oFerand INVALID HEXDATA - hexdata CONFLICTING OPTION - option USERID MISSING OR INVALID OPERAND MISSING OR INVALID userid NOT LOGGED ON CPTRAP IS STOPPING, NC INPUT ALLOWED CPTRAP SELECTIVITY RESET CPTRAP IS ALREADY ACTIVE OPERAND IGNORED SELECT TABLE FOLL DMKTRR002E DMKTRR005E DMKTRR008E DMKTRR026E INVALID O~ERANt - oFerand INVALID HEXDATA - hexdata INVALID SPOOLID - spoolid OPERAND MISSING OR INVALID Appendix B. Message Summary Alphamerically by Message Identifier 295 DMK DMKTRR027E DMKTRR042E DMKTRR301E DMKTRR302E DMKTRE303E DMKTRR3051 DMKTRR764E SPOOLID MISSING OR INVALID SPOOLID nnnn DOES NCT EXIST OR IS BELt REQUESTED FILE IS NO~ A CPTRAP FILE I/O ERROR ON OOC - IXXXXXXXIX OOC READER FILE NOT LOCATABLE TRAPRED SELEC~IVITY RESET ERROR IN ROUTINE XXIXXXXX DMKTRT3071 CPTRAP CCP/VIRTUAL) ecce INTERFACE DMKTRT3081 CPTRAP DATA LOST DA~A IGNORED DMKUDR4751 FATAL 10 ERROR TRYING TO READ DIRECTORY DMKUS0003E DMKUS0020E DMKUS0045E DMKUS0197E INVALID OPTION - option USERID MISSING OR INVALID userid NOT LOGGED ON SECONDARY USER IS NOT AVAILAElE DMKVAT064E SHADOW TABLE BYPASS: RESE~ DMKVCH034E DMKVCH048E DMKVCH129E DMKVCH130E DMKVCH132E DMKVCH138E DMKVCH147E DMKVCH188E CHANNEL MISSING CR INVALID CHANNEL x DOES NOT EXIST CHANNEL x DEVICES IN USE CHANNEL x [PROC nn] NO~ ATTACHED TO userid CHANNEL x ALREADY DEFINED BY userid CHANNEL x NOT ATTACHED: INSUFFICIENT FREE STORAGE CHANNEL x [PROC nn] NeT ATTACHED: ALTERNATE PATHS DEFINED SPECIFIED PROCESSOR UNAVAILABLE DMKVDA039E DMKVDA076E DMKVDA077E DMKVDA135E DMKVDA140E PROCESSOR ADDRESS MISSING CR INVALID THE 'volid' PARAMETER IS INVALID INVALID REQUEST FOR DEVICE 'nnn' TYPE vaddr NO~ DE~ACHED: CHAN x DEDICATED type raddr ATTACHED TC userid DMKVDD006E DMKVDD020E DMKVDD021E DMKVDD022E DMKVDD040E DMKVDD045E DMKVDD046E DMKVDD121E DMKVDD123E DMKVDD124E DMKVDD134E DMKVDD135E DMKVDD140E DMKVDD142E DMKVDD143E DMKVDD273E INVALID DEVICE TYPE - addr USERID MISSING OR INVALID RADDR MISSING OR INVALID raddr VADDR MISSING OR INVALID vaddr DEV addr DOES NOT EXIST userid NOT LOGGED ON {DEV ridltype raddr} OFFLINE [PRT ridltype raddr] NOT ATTACHED TO userid DASD raddr CP OWNED DASD raddr IN USE BY nnn OSERS CHANNEL MISSING OR INVALID TYPE vaddr NOT DETACBEt; CHAN x DEDICATED type raddr ATTACHED TO userid type raddr NOT· DRAINED type raddr IN USE BY SYSTEM DETACH REJ VIRTUAL MACHINE TRACING I/O DMKVDE003E DMKVDE006E DMKVDE020E DMKVDE021E DMKVDE022E DMKVDE023E DMKV.DE034E DMKVDE039E DMKVDE040E DMKVDE045E DMKVDE046E DMKVDE120E DMKVDE121E DMKVDE122E DMKVDE123E DMKVDE124E DMKVDE125E DMKVDE126E DMKVDE127E DMKVDE128E DMKVDE131E INVALID OPTION - option INVALID DEVICE TYPE - addr USERID MISSING OR INVALID RADDR MISSING OR INVALID raddr VADDR MISSING OR INVALID vaddr VOLID MISSING OR INVALID CHANNEL MISSING OR INVALID PROCESSOR ADDRESS HISSING OR INVALID DEV addr DOES NOT EXIST userid NOT LOGGED ON {DEV ridltype raddr} OFFLINE [PRT ridltype raddr] NeT ATTACBED: userid vaddr ALREADY DEFINED [PRT ridltype raddr] NOT ATTACHED TO userid [PRT ridltype raddr] ALREADY AT~ACHED TO userid DASD raddr CP OWNED DASD raddr IN USE BY nnn USERS DASD raddr VOLID volid ALREADY ATTACHED TO SYSTEM DASD raddr ERROR READING VOLID DASD raddr VOLID volid DOES NCT MATCH DASD raddr ERROR READING ALLOCATION BECORD INSUFFICIENT FREE STCBAGE AVAILABLE FCR ATTACH REQUESt 296 IBM VM/SP System Messages and Codes DMK DMKVD!133! DMKVD!134! DMKVD!142! DMKVD!143E DMKVDE153! DMKVDE199E DMKVDE9621 DASD raddr NOT READY TYPE vaddr NOT ATTACHED; CHAN X DEDICATED type raddr NOT DRAIBED type raddr IN USE BY SYSTEM DEVICE {vaddrIRNG} EXCEEDED MAX NUMBER OF VIRTUAL DEVICES COMMAND REJECTED; DEVICE raddr PENDING OFFLINE CP OWNED DASD cuu VCIID volid INVALID ALLOCATION RECORD D.ftKVDS465W CTLR raddr EMULATOR LIBES IN USE BY SYSTE! DMKVER5151 1/0 ERROR ADD=raddr, USERID= userid DMKVMA161E SHARED PAGE hexloc ALTERED BY userid DMKVMAQ56W CP ENTERED; name SHAREt PAGE bexloc ALTERED DMKVMD009! DMKVMD013E DMKVMD020E DMKVMD033E DMKVMD038E DftKVMD053E DMKVMD146I DMKVMD160E INVALID RANGE - range CONFLICTING OPTION - option USERID MISSING OR IBVALID HEXLOC MISSING OR INVALID PARAMETER parameter FOR option OPTION MISSING OR INVALID userid NOT IN CP DIRECTORY VMDUMP FAILED, SPOOLING ERROR HEXLOC hexloc EXCEEtS STORAGE DMKVMI022E DMKVMI230E DMKVMI231E DMKVMI232E DMKVMI233E DMKVMI234E VADDR MISSING OR INVALID IPL SIO ERROR IPL TIO ERROR IPL UNIT ERROR; CSW csw SNS sense 1PL OVERLAY ERROR IPL SENSE ERROR DMKVSP421I {CONIPRTIPUN} vaddr SYSTEM SPOOL SPACE FULL; FILE CLOSED DMKVSP429I {CONIPRTIPUNIRDR} vaddr SFOeL ERROR; FILE {HELDIPURGED} DMKVST421I {CONIPRTIPUN) vaddr SYSTEM SPOOL SPACE FULL; FILE CLOSED DMKVST429I {CONIPRTIPUNIRDR} vaddr SPOOL ERROR; FILE {HELDIPURGED} DMKWRM904W DMKWRM912W DMKWRM9201 DMKWRM921W SYSTEM RECOVERY FAIlURE; SYSTEM RECOVERY FAILURE; NO WARM START DATA; CKFT SYSTEM RECOVERY FAILURE; INVAlID WAR! START DATA VOLID 'volia' NOT MCUNTED START FOR RETRY UNRECOVERABLE 1/0 ERROR App~naix B. Message Summary Alphamerically by Message Identifier 291 Dl!S eMS Message Summary DMSABN148T DMSABN149T Dl!SAEN1S0W DMSABN1S2T DMSABN1S3W DMSABN1SST SYSTEM ABEND xxx CALLED FROM 'addr' nnn (HEX xxx) DOUBIEWORDS OF SYSTEM STORAGE HAVE BEEN DESTROYED. RE-IPL CMS nnn (HEX xxx) DOUELEWORDS OF SYSTEM STORAGE WERE NOT RECOVERED SYSTEM ABEND xxx CALLED FROM addr WHILE 'UFDBUSY' = xx. RE-IPL CMS 'HX' DURING ABEND PECCESSING WAS IGNCRED USER ABEND nnnn CALLED FROM addr DMSACC002E DMSACC003E DMSACC017E DMSACC048E DMSACCOS9E DPISACC060E DMSACC109S DPISACC112S DPISACC113S DMSACC230W DPISACC240S DMSACC7231 DMSACC7241 DMSACC72S1 DMSACC7261 [I~PUTI OVERLAY] {FIIE[ (S) )I tAT A SET} [' fn [ft [fm]]I] NOT FOUND INVALID OPTION 'option' INVALID DEVICE ADDRESS 'cuu' INVALID MODE 'mode' 'cuu' ALREADY ACCESSED AS READ/WRITE 'mode' DISK FILE (S) 'fn [ft [fm]]' NOT FCUND. DISK 'mode (cuu) , WILL NOT BE ACCESSED VIRTUAL STORAGE CAPACITY EXCEEDED DISK '.mode (cuu)' DEVICE ERROR {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUT} (cuu) NOT ATTACHED OS DISK - FILElt AND/OR OPTIONS SPECIFIED ARE IGNORED ERROR LOADING READ CS ROUTINE 'tMSROS TEXT' mode (cuu) {R/O I R/W} [-OS I-DOS] cuu REPLACES mode (ccu) cuu ALSO = 'mode' [-OS I-DOS] DISK 'cuu mode' RELEASED Dl!SALT520E INVALID OPERAND : operand DMSALTS4SE MISSING OPERAND(S} DMSAMS001E DMSAMS002E DMSAMS003E DMSAMS006E DMSAPIS007E DMSAMS065E Dl!SAl!S066E Dl!SAMS070E DMSAMS109S DMSAMS113S Dl!SAMS136S DMSAMS228E DMSAMS367R DMSAMS7221 NO FILENAME SPECIFIEt [INPUTIOVERLAY] {FILE[(~ ]IDATA SET} ['fn [ft [fm]]'] NOT FOUND INVALID OPTION 'option' NO READ/WRITE ['A'] DISK ACCESSED [FOR 'fn ft'] FILE 'fn ft fm' [IS] NCT FIXEt, aO-CHAR. RECORDS 'option' OPTION SPECI!IED TWICE 'option' AND 'option' ARE CONFLICTING OPTIONS INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} VIRTUAL STORAGE CAPACITY EXCEEDED {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUT} (cuu) NOT ATTACHED UNABLE TO LOAD 'IDCMA5' NO DDNAME ENTERED ENTER TAPE {INPUTIOUTPUT} DDNAMES: FILE 'fname2 LISTING fm' WILL HCID AMSEBV OUTPUT DMSARE017E Dl!SARE028E DMSARE048E Dl!SARE069E Dl!SARE070E INVALID DEVICE ADDRESS 'cuu' NO {DEVICEILOGICAL ONIT} SPECIFIED INVALID MODE 'mode' DISK {'mode" 'cuU'I'volid'} NCT ACCESSED INVALID [PARAMETER 'parameter'IARGUMENT 'argument'} Dl!SARN001E Dl!SARN002E DMSARN003E DMSARN004W DMSARN006E DMSARN007E DMSARN008W DMSARN012W Dl!SARN016W NO FILENAME SPECIFIED [INPOTIOVERLAY] {FIIE[ (S) ]IIATA SET} [Itn [ft [fm]]'] NOT FOUND INVALID OPTION 'option' WARNING MESSAGES ISSUED NO READ/WRITE ['A'] DISK ACCESSED [FOR Ifn ft'] FILE 'fn ft fm' [IS] NeT FIXED, 80 CHAR. RECORDS ERROR MESSAGES ISSUED SEVERE ERROR MESSAGES ISSUED TERMINAL ERROR MESSAGES ISSUED Dl!SARX001E DPISARX002E DMSARX003E DMSARX006E DMSARX007E DMSARX038E DMSARX052E DMSARX070E DMSARX074E DMSARX07SE NO FILENAME SPECIFIEt [INPUTIOVERLAY] {FILE[ (S) ]fDATA SET} ['fn [ft [fm]]'] NOT FOUND INVALID OPTION 'option' NO READ/WRITE ['A'] DISK ACCESSED [FOR 'fn ft'] FILE 'fn ft fm' [IS] NCT FIXED, 80-CHAR. RECORDS FILEID CONFLICT FOR ttNAM! IASM370S' MORE THAN 100 CHARS OF OP1IONS SPECIFIED INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} ERROR SETTING/RESETTING AUXILIARY DIRECTORY [DEVICE] devicename {INVAIIDIIIIEGAL} FCR {INPUTIOUTPUT} Dl!SASl!001E NO FILENAME SPECIFIED Dl!SASl!002E [INPUTIOVERLAY] {FIIE[ (S) ]1 tAT A SET} ['tn eft [fm]]'] NOT FOUND 298 IBM VM/SP System MessagES and Codes DMS DMSASM003E DMSASM006E DMSASM007E DMSASM038E DMSASM052E DMSASM070E DMSASM07qE DMSASM075E INVALID OPTION 'option' NO READ/WRITE ['A'] DISK ACCESSED [FOR 'fn ft'] FILE 'fn ft fm' [IS] NCT FIXEt, 80-CHAR. RECORDS FILEID CONFLICT FOR DDNAME 'ASSEMELE' MORE THAN 100 CHARS OF OPiIONS SPECIFIED INVALID (PARAMETER 'parameter'IARGUMENT 'argument') ERROR SETTING/RESETiING AUXILIARY DIRECTORY [DEVICE] devicename {INVALIDIILIEGAL} FOR {INPUTIOUTPUT} DMSASN003E DMSASN027E DMSASN028E DMSASN029E DMSASN035E DMSASN050E DMSASN065E DMSASN066E DMSASN069E DMSASN070E DMSASN087E DMSASN090E DMSASN099E DMSASN113S DMSASN366E INVALID OPTION 'option' INVALID DEVICE {'device name'I'device' FOR 'SYSxxx'} NO (DEVICEILOGICAL UNIi) SPECIFIED INVALID PARAMETER 'parameter' IN THE OPiION 'option' FIELD INVALID TAPE MCDE PARAMETER MISSING AFTER {DDNA~EISYSxxxlfunction} 'option' OPTION SPECIFIED TiICE 'option' AND 'option' ARE CONFLICTING OPTIONS DISK ('mode'l 'cuu' I 'valid ') NCT ACCESSED INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} INVALID ASSIGNMENT OF 'SYSxxx' iO DEVICE 'device' INVALID DEVICE CLASS 'deviceclass' FOR 'device' CMS/DOS ENVIRONMENi NO~ ACiIVE (modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUT) (cuu) NO CMS/DOS SUPPORi FOR NAiIVE 3380 DISK DMSBOP037E DMSBOPOQ3E DMSBOF058E DMSBOP069E DMSBOP086W DMSBOP088E DMSBOP089E DMSBOP113S DMSBOP302E DMSBOP308E DMSBOPQOOS DMSBOP401S DMSBOPQ03S DMSBOFQ04S DMSBOP410S DMSBOPQ13S [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY 'TAPn(cuu)' IS FILE ERCTECTED END-OF-FILE OR END-OF-TAPE [ON 'iAPn'] DISK (' mode' I 'cuu' I 'valid ') NeT ACCESSED DLBL 'ddname' DUMMY INVALID FOR VSAM UNSUPPORTED DTF TIPE 'dtftype' {OPENICLOSE} ERROR CODE 'nn' ON {fnISYSxxxITAPn} {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUT} (cuu) NOT ATTACHED NO SYSxxx OPERAND {ENiEREDISPECIFIED} 'mode' DISK IN [NON-]CMS FORMAT; INVALID FOR [NON-]CMS DATASET SYSTEM 'sysname' IOES NOT EXIST VM SIZE (size) CANNOi EXCEED 'sjsname' START ADDRESS (address) filename SHARED SEGMENi NCT AVAILABLE. RELOAD CMSDOS filename LOGIC MODULE NOT FOUND IN 'segname' SHARED SEGMENT CONTROL PROGRAM ERROR INDICATION 'retcode' STORAGE NOT INITIALIZED FCR VSAM PROCESSING NOT AiTACHED DMSBTE100E NO BATCH PROCESSOR AVAILAELE DMSBTE101E BATCH NOT LOADED DMSBTF105E DMSBTP106E DMSBTP107E DMSBTP108E DMSBTP109E NO JOB CARD PROVIDED JOB CARD FORMAi INVALID CP/CMS COMMAND 'command, (device)' NOT ALLOiED /SET CARD FORMAT INVALID (CPUIPRINTERIPUNCH) LIMIT EXCEEDED DMSBWR107S DISK 'mode {(cuu})' IS FULL DMSBWB109S VIRTUAL STORAGE CAPACI~Y EXCEEDED DMSBWR170S DISK 'mode (cuu) , HAS MAXIMUM NUMBER OF FILES DMSCAN520E INVALID OPERAND : operand DMSCI0113S {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUT} DMSCI0145S INTERVENTION REQUIRED ON {PRINTERIPUNCH} (cuu) NOT ATTACHED DMSCIT171T PERMANENT CONSOLE ERRCR, EE-IPL CMS DMSCLS043E DMSCLS058E DMSCLS088E DMSCLS089E DMSCLS113S DMSCLS140S DMSCLS429I 'TAPn(cuu), IS FILE ERCTECTED END-OF-FILE OR END-OF-iAPE [ON 'TAPn'] UNSUPPORTED DTF TYPE 'dtftype' (OPENICLOSE) ERROR CODE Inn' ON {fnISYSxxxITAPn} (model DEVICE I DISKIPRINTERIFUNCHIREADERITAPnlTAPINITAPO UT) (cuu) NOT ATTACHED {'function'IFEOVDISEOVIFEOV} (!ACROIFUNCTION{S)} MACRO NOT SUPPORTED 'TAPn (cuu)' EOT ON OUiPUT DMSCMP002E [INPUTI OVERLAY] {FIIE[ (S) ] I DATA SET} [' fn [ft [fm]]'] NOT FOUND DMSCMF003E INVALID OPTION 'option' DMSCMP005E NO 'option' SPECIFIED Appendix B. Message Summary Alphamerically by Message Identifier 299 DMS DMSCMP009E DMSCMP010E DMSCMP011E DMSCMP019E DMSCMP029E DMSCMP054E DMSCMP062E DMSCMP069E DMSCMF104S DMSCMP109S DMSCMP1791 COLUMN 'col' EXCEEDS RECOED LENGTH PREMATURE EOF ON FILE 'fn ft [fm]' CONFLICTING FILE FOB!ATS IDENTICAL FILEIDS INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD INCOMPLETE FILEID SPICIFIEt INVALID [CHARICHARACTER] '[=I*lchar)' IN [OUTPUT] FILEID ['fn ft (fm]'] DISK {'mode'l 'cuu'l 'valid'} NeT ACCESSED ERROR 'nn' READING FILE 'fn ft fm' FROM DISK VIRTUAL STORAGE CAPACITY EXCEEDED COMPARING 'fn ft fm' ~ITH 'fn ft fm' DMSCMP209~ FILES DO NOT COMPARE DMSCMP211E COLUMN FIELDS CUT OF SEQUENCE DMSCMS006E DMSCMS095E DMSCMS110E DMSCMS111E DMSCMS141S DMSCMS412S DMSCMS715I NO READ/WRITE ['A'] DISK ACCESSED [FOR 'fn ft'] INVALID ADDRESS 'address' CORRECT FORM IS: {DOSGENICMSXGEN} LOCATION (SEGNAME) {DOSGENICMSXGEN} FAIIEt DUE TC lOAD ERRORS CMSXGEN FAILEt DUE TC SAVESYS ERRORS CMSXGEN FAILEt DUE TO SETKEY ERROR {DOSGENICMSXGEN} COMPLETE DMSCPY002E DMSCPY003E DMSCPY024E DMSCPY029E DMSCPY030E DMSCPY037E DMSCPY042E DMSCPY048E DMSCPY054E DMSCPY062E DMSCPY063E DMSCPY064E DMSCPY065E DMSCPY066E DMSCPY067E DMSCPY068E DMSCPY069E DMSCPY101S DMSCPY102S DMSCPY103S DMSCPY156E DMSCPY157E DMSCPY172E DMSCPY173E DMSCPY601R DMSCPY602R DMSCPY7211 DMSCPY901T DMSCPY903T DMSCPY904T [INPUTIOVERLAY] {FILE[ (S) ]IDATA SET} ['fn (ft (fm]]') NOT FOUND INVALID OPTION 'option' FILE 'fn ft fm' ALREAtY EXISTS [-- SPECIFY 'REPLACE') INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD FILE 'fn ft fm' ALREADY ACTIVE [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY NO FILEID(S) SPECIFIEt INVALID MODE 'mode' INCOMPLETE FILElt SPECIFIED INVALID [CHARICHARACTER] '[=I*lchar]' IN [OUTPUT] FILEID ['fn ft [fm]'] NO [SORTITRANSIATICNISPECIFICATION] LIST {ENTEREDIGIVEN} INVALID [TRANSLATE] SPECIFICATION AT OR NEAR ••••••••••• 'option' OPTION SPECIFIED TWICE 'option' AND 'option' ARE CONFLICTING OPTIONS COMBINED INPUT FILES ILLEGAL WITH PACK OR UNPACK OPTIONS INPUT FILE 'fn ft fm' NOT IN PACKED FORMAT DISK {'mode'I'cuu'I'volid'} NOT ACCESSED 'SPECS' TEMP STRING STCRAGE EXHAUSTED AT ••••••••• , TOO MANY FILEIDS NUMBER OF SPECS EXCEEDS MAX 20 'FROM nnn' NOT FOUNt - FILE 'fn ft fm' HAS ONLY 'nnn' RECORDS LABEL 'label' NOT FOUND IN FILE 'fn ft fm' TO LABEL 'label' {EQUAISIIS AN INITIAL SUBSTRING OF} FRLABEL 'label' NO RECORDS WERE COPIEt TO OUTPUT FILE 'fn ft fm' ENTER SPECIFICATION lIST: ENTER TRANSLATION LIST: COpy 'fn ft fm' [{TOIAFPENDIOVLY} 'fn ft fm' {OLDINEW} FILE] UNEXPECTED ERROR AT 'addr': PLIST 'plist fn ft fm' AT addr, BASE addr, RC nn IMPOSSIBLE PHASE CODE 'xx' UNEXPECTED UNPACK ERRCE AT 'addr', BASE 'addr' DMSCRD171T PERMANENT CONSOLE ERROR RE-IPL CMS. DMSCVH161S UNEXPECTED ERROR CODE 'nnw ON 'SYSxxx' DMSCWE171T PERMANENT CONSOLE ERROR RE-IPI CMS. DMSDAS140S {'function'IFEOVDISECVIFEOV} {~ACROIFUNCTION(S)} MACRO NOT SUPPORTED DMSDBG113S {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUT} DMSDBG7281 DEBUG ENTERED [EXTERNAL INTI BREAKPOINT nn AT xxxxxx] DMSDDL003E DMSDDL006E DMSDDL024E DMSDDL070E DMSDDL078E DMSDDL545E DMSDDL636E DMSDDL636W DMSDDL637E 300 INVALID OPTION 'option' NO READ/WRITE DISK ACCESSED FCR 'fn ft' FILE 'fn ft fm' AIREALY EXISTS -- SPECIFY 'REPLACE' OPTION INVALID PARAMETER 'parameter' INVALID CARD IN READER DECK MISSING OPERAND(S) UNSUPPORTED TYPE OF NETDATA FILE RECEIVED NULL FILE -- NO FILE CREATED MISSING VALUE FOR THE 'NOTEBOOK' OPTION IBM VM/SP System Messages and Codes (cuu) NOT ATTACHED DMS DMSDDL63aE 'file' IS TOO iIDE TO APPEND to 'fn ft' DMSDDL639E EBBOB IN 'routine' ROUTINE. RETURN CODE WAS 'nnw DMSDI090SS WBITE-INHIBIT SWITCH SET CN tRIVE ••• NOTIFY OPERATOR DMSDLE001E DMSDLE003E DMSDLBOOSE DMSDLE023E DMSDLB04aE DMSDLBOSOE DMSDLE065E DMSDLE066E DMSDLB069E DMSDLE070E DMSDLEOa6E DMSDLB109S DMSDLB220R DMSDLB221E DMSDLE301E DMSDLB302E DMSDLE304E DMSDLE30SE DMSDLB306E DMSDLE307E DMSDLB308E DMSDLE3201 DMSDLB321I DMSDLB3221 DMSDLB3231 DMSDLE324I DMSDLB330R DMSDLB331R NO FILENAME SPECIPIED INVALID OPTION 'option' NO 'option' SPECIFIED NO FILETYPE SPECIPIED INVALID MODE 'mode' PARAMETER MISSING AFTER (DDNAMEISYSxxxlfunction) 'option' OPTION SPECIFIED TWICE 'option' AND 'option' ARE CONFLICTING OPTIONS DISK ('mode'l 'cuu' I 'volid') NCT ACCESSED INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} INVALID DDNAME 'ddname' VIRTUAL STORAGE CAPACITY EXCEEDED ENTER DATA SET NAME: INVALID DATA SET NAME 'SYSxxx' NOT ASSIGNED FOR DISK 'fm' NO SYSxxx OPERANt (ENTEREDISPECIFIED) INVALID OPERAND VALUE 'value' INCOMPLETE EXTENT RANGE SYSxxx NOT ASSIGNED FCE 'IGNOEE' CATALOG DDNAME 'ddname' NOT FOUND 'mode' DISK IN [NON-]CMS FORMAT; INVALID FOR [NON-]CMS DATASET MAXIMUM NUMBER OF DISK ENTRIES RECORDED MAXIMUM NUMBER OF EXTENTS RECORDED 'ddname' NOT FOUND: NO CLEAR EXECUTED (MASTERIJOB) CATALOG tlBL CLEARED NO USER DEFINED {DLELIFILEDEFILABELDEF)'s IN EFFECT ENTER VOLUME SPECIFICATIONS: ENTER EXTENT SPECIFICATIONS: DMSDLK001E DMSDLK003E DMSDLK006E DMSDLK007E DMSDLK070E DMSDLK099E DMSDLK104S DMSDLK10SS DMSDLK210E DMSDLK24SS NO FILENAME SPECIFIEt INVALID OPTION 'option' NO READ/WRITE ['A'] DISK ACCESSED [FOR 'fn ft'] FILE 'fn ft fm' [IS] NOT FIXED, 80 CHAR. RECORDS INVALID (PARAMETER 'parameter'IARGUMENT 'argument') CMS/DOS ENVIRONMENT NCT ACTIVE ERROR 'nne READING FILE 'tn tt fm' FROM DISK ERROR 'nn' WRITING FILE 'fn ft fm' ON DISK (LIBRARYIFILE) 'fn ft' IS ON A READ-ONLY DISK ERROR 'nnn' ON PEINTEE DMSDMP020W INVALID PDUMP ADDRESS 'address' - NO DUMP OPERATION PERFORMED DMSDOS004E DMSDOS069E DMSDOS091E DMSDOS092E DMSDOS093E DMSDOS094E DMSDOS09SE DMSDOS096S DMSDOS119S DMSDOS121S DMSDOS140S DMSDOS160S DMSDOS161S DMSDOS401S DMSDOS413S (BOOK 'subl.book'IMODULE 'module'IPHASE 'phase'IPROCEDURE 'procedure') NOT FOUND DISK ('mode'j'cuu'j'volid') NCT ACCESSED SAVEAREA ADDRESS IN PARTITION PIB NOT EQUIVALENT TO LTA SAVEAREA ADDRESS STXIT SAVEAREA ADDRESS INVALID MVCOM MACRO ATTEMPT TO ALTER OTHER THAN POSITION 12-23 OF COMREG FROM ADDRESS ON MVCOM MACEO INVALID INVALID ADDRESS 'ada~ess' UNSUPPORTED FUNCTION IN A LICCS ROUTINE UNSUPPORTED FORM OF {'macro'j'parm'} {IUCROjSVC} UNSUPPORTED SVC svc (HEX xx) CALLED FROM addr ('function'jFEOVDjSEOVjFEOV) {MACROjFUNCTION(S}) MACRO NOT SUPPORTED JOB CANCELED DUE TO PROGRAM REQUEST UNEXPECTED ERROR CODE Inn' ON 'SYSxxx' VM SIZE (size) CANNOT EXCEED ~iysname' START ADDRESS {add~ess} STORAGE NOT INITIALIZED FCR VSAM PROCESSING DMSDS",;K002E DMSDSK009E DMSDSK014E DMSDSK037E DMSDSK047E DMSDSK04aE DMSDSKOS4E DMSDSK062E DMSDSK070E DMSDSK077E [INPUT j OVERLAY] {FILE[ (S) J I DATA SET) [' fn [ft [fm]]'] NOT FOUND ' COLUMN 'col' EXCEEDS RECORD LENGTH INVALID KEYWORD 'function' [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY NO FUNCTION SPECIFIED INVALID MODE 'mode' INCOMPLETE FILEID SPECIFIED INVALID [CHARICHARACTER] '[=I*lchar]' IN [OUTPUT] FILEID ['fn ft [fm]'] INVALID (PARAMETER 'pa~amete~'jARGUMENT 'argument') END CARD MISSING FRCM INPUT DECK Appendix B. Message Summary Alphamerically by Message Identifier 301 DMS DMSDSK078E DMSDSK078W DMSDSK104S DMSDSK105S DMSDSK118S DMSDSK124S DMSDSK205W DMSDSK445W DMSDSK496S INVALID CARD IN READER {DECKIFIIE 'cardimage'} SEQUENCE ERROR DETECTED LOADING 'fn ft' EXPECTED ' , FOUN ERROR Inn' READING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK ERROR PUNCHING FILE {'fn ft fm'} ERROR READING CARD FILE READER EMPTY eR NOT READY INVALID DATA IN SEQUENCE FIELD, BYPASSING SEQUENCE CHECK READER FILE ALTERED TO DISK LCAD AS: 'fn ft fm' DISK LOAD STOPPED FILE HAS BEEN LEFT IN YOUR READER DMSDSK550W DATE/TIME DATA NOT PRESENT FOR FILE 'fn ft' DMSDSL002E DMSDSL003E DMSDSL013W DMSDSL014E DMSDSL037E DMSDSL046E DMSDSL047E DMSDSL069E DMSDSL070E DMSDSL098E DMSDSL104S DMSDSL105S DMSDSL213W [INPUTIOVERLAY] {FILE[ (S) JlDATA SET} ['fn [ft [fm]]'] NOT FOUND INVALID OPTION 'option' {MEMBERIPHASE} 'name' NOT FOUND IN LIBRARY 'libname' INVALID KEYWORD 'function' [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY NO LIBRARY NAME SPECIFIED NO FUNCTION SPECIFIED DISK {'mode'l 'cuu' I 'volid'} NCT ACCESSED INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} NO {PHASEIPROCEDURE} NAME SFECIFIED ERROR 'nn' READING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK LIBRARY 'fn ft fm' NeT CREATED DMSDSV003E DMSDSV021W DMSDSV022W DMSDSV023W DMSDSV024W DMSDSV025W DMSDSV026W DMSDSV027E DMSDSV027W DMSDSV028W DMSDSV047E DMSDSV065E DMSDSV066E DMSDSV070E DMSDSV095E DMSDSV099E DMSDSV105S DMSDSV245S INVALID OPTION 'option' NO TRANSIENT DIRECTORY NO CORE IMAGE DIRECTORY NO RELOCATABLE DIRECTCRY NO PROCEDURE DIRECTORY NO SOURCE STATEMENT DIRECTORY 'phase' NOT IN LIERARY INVALID DEVICE {'device name'I'device' FOR 'SYSxxx'} NO PRIVATE CORE IMAGE lIBRARY NO {PRIVATEISYSTEM} TRANSIENT DIRECTORY ENTRIES NO FUNCTION SPECIFIED 'option' OPTION SPECIFIED TWICE 'option' AND 'option' ARE CONFLICTING OPTIONS INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} INVALID ADDRESS 'address' CMS/DOS ENVIRONMENT NOT ACTIVE ERROR Inn' WRITING FILE 'fn ft fm' ON DISK ERROR 'nnn' ON PRINTER DMSEDI003E DMSEDI024E DMSEDI029E DMSEDI044E DMSEDI054E DMSEDI069E DMSEDI076E DMSEDI104S DMSEDI105S DMSEDI117S DMSEDI132S DMSEDI143S DMSEDI143S DMSEDI143S DMSEDI144S INVALID OPTION 'option' FILE 'fn ft fm' ALREADY EXISTS [-- SPECIFY 'REPLACE'] INVALID PARAMETER 'parameter' IN THE CPTION 'option' FIELD RECORD LENGTH EXCEEDS ALLOWAEIE MAXIMUM INCOMPLETE FILEID SPECIFIED DISK {'mode'l 'cuu'I'volid'} NCT ACCESSED ACTUAL RECORD LENGTH EXCEEDS THAT SPECIFIED ERROR Inn' READING FILE 'fn ft fm' FEOM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK ERROR WRITING TO DISPLAY TERMINAL FILE 'fn ft fm' TOO LARGE UNABLE TO LOAD SAVED SYSTEM OR LOAD MODULE ['ERROR CODE nn' ] UNABLE TO LOAD SAVED SYSTEM OR LOAD MODULE ['ERROR CODE nn' ] UNABLE TO LOAD SAVED SYSTEM OR LOAD MODULE ['ERROR CODE nn' ] REQUESTED FILE IS IN ACTIVE STATUS DMSEDX069E DISK {'mode' l'cuu'I'volid'} NOT ACCESSED DMSEI0618E DMSEI0621E DMSEI0622E DMSEI0632E NUCEXT FAILED BAD PLIST: XXXXX INSUFFICIENT FREE STORAGE FOR EXECIO I/O ERROR IN EXECIO: RC=XXX FROM 'command' COMMAND DMSERR215T NO VIRTUAL CONSOLE ATTACHED. RE-IPL CMS DMSERS002E [INPUTIOVERLAY] {FILE[ (~]IDATA SET} ['fn [ft [fm]]'] NOT FOUND DMSERS003E INVALID OPTION 'option' DMSERS037E [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY 302 IBM VM/SP System Messages and Codes OMS DMSERS048E DMSERS054E DMSERS069E DMSERS070E DMSERS071E DMSERS109T INVALID MODE 'mode' INCOMPLETE FILEID SPECIFIED DISK {'mode'l 'cuu'l 'valid'} NOT ACCESSED INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} ERASE * * [fml*] NOT ALLOWED VIRTUAL STORAGE CAPACITY EXCEEDED DMSERV001E DMSERV002E DMSERV006E DMSERV027E DMSERV037E DMSERV070E DMSERV099E NO FILENAME SPECIFIED (INPUTIOVERLAY] {FIIE[ (S) ]IDATA SET} ['fn [ft [fm])'] NOT FOUND NO READ/WRITE ['A'] DISK ACCESSED [FOR 'fn ft'] INVALID DEVICE {'device name'\'device' FOR 'SYSxxx'} [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} CMS/DOS ENVIRONMENT NOT ACTIVE DMSEXC001E NO FILENAME SPECIFIED DMSEXE085E ERROR IN fn ft fm, lINE nnn - message DMSEXE175E INVALID EXEC COMMAND DMSEXE255T INSUFFICIENT STORAGE FOR EXEC INTERPRETER DMSEXT072E ERROR IN EXEC FILE fn LINE nnn - message DMSFCH016E DMSFCH104S DMSFCH109S DMSFCH113S DMSFCH115E DMSFCH411S DMSFCH623S NO PRIVATE CORE IMAGE LIBRARY FOUND ERROR 'nne READING FILE 'fn ft fm' FROM DISK VIRTUAL STORAGE CAPACITY EXCEEDED {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOU~ (cuu) NOT ATTACHED PHASE LOAD POINT LESS THAN 'address' {INPUTIOUTPUT} ERROR CODE 'nn' ON 'SYSxxx' PHASE CANNOT BE LOADED AT LOCATION 'location' BECAUSE IT WOULD OVERLAY THE CMS NUCLEUS DMSFCH777S DOS PARTITION TOO SMALL TO ACCOMMODATE FETCH REQUEST DMSFET003E DMSFET004E DMSFET029E DMSFET070E DMSFET098E DMSFET099E DMSFET623S INVALID OPTION 'option' {BOOK 'subl.book'IMODULE 'module'IPHASE 'phase'IPROCEDURE 'procedure'} NOT FOUND INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD INVALID {PARAMETER 'parameter'IARGUHENT 'argument'} NO {PHASEIPROCEDURE} NAME SPECIFIED CMS/DOS ENVIRONMENT NOT ACTIVE PHASE CANNOT BE LOADED AT LOCATION 'location' BECAUSE IT WOULD OVERLAY THE CMS NUCLEUS DMSFET7101 PHASE 'phase' ENTRY POINT AT LOCATION XXXXXX DMSFLD003E DMSFLD023E DMSFLD027E DMSFLD029E DMSFLD035E DMSFLD050E DMSFLD065E DMSFLD066E DMSFLD0691 DMSFLD070E DMSFLD220R DMSFLD221E DMSFLD224E DMSFLD3241 DMSFLD420E DMSFLD7041 DMSFLE495E DMSFNS109T DMSFNS908T DMSFNS909T DMSFOR003E DMSFOE005E DMSFOR017E DMSFOR028E DMSFOR037E DMSFOR048E DMSFOR069E DMSFOR070E INVALID OPTION 'option' NO FILETYPE SPECIFIED INVALID DEVICE ('device name"'device' FOR 'SYSxxx') INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD INVALID TAPE MODE PARAMETER MISSING AFTER {DDNAMEISYSxxXlfunctionJ 'option' OPTION SPECIFIED TWICE 'option' AND 'option' ARE CONFLICTING OPTIONS DISK {'mode'l'cuu"'volid'} NOT ACCESSED INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} ENTER DATA SET NAME: INVALID DATA SET NAME FILEID ALREADY IN USE NO USER DEFINED FILEDEF'S IN EFFECT NSL EXIT FILENAME MISSING OR INVALID INVALID CLEAR REQUEST THE 'module' MODULE CAN ONLY BE EXECUTED BY THE 'module2' MODULE, IT CANNOT BE EXECUTED BY ITSELF VIRTUAL STORAGE CAPACITY EXCEEDED FILE SYSTEM ERROR DETECTED. VIRTUAL ADDR 'cuu'. REASON CODE Inn'. PERM I/O ERROR ON ·cuu'. CSW cccccccc cccccccc SENSE ssssssss ssssssss ssssssss ssssssss ssssssss ssssssss. INVALID OPTION 'option' NO 'option' SPECIFIED INVALID DEVICE ADDRESS 'cuu' NO {DEVICEILOGICAL UNIT} SPECIFIED [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY INVALID MODE 'mode' DISK {'mode'l 'cuu'I'volid'} NOT ACCESSED INVALID {PARAMETER 'parameter'IARGUHENT 'argument'} Appendix B. Message Summary Alphamerically by Message Identifier 303 DMS DMSFOR113S DMSFOE114S DMSFOE125S DMSFOR126S DMSFOE214W DMSFOR216E DMSFOR253E DMSFOR603R DMSFOE605R DMSFOR7051 DMSFOR7321 DMSFOR733I {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUTI (cuu) NOT ATTACHED 'cuu' IS AN UNSUPPORTED DEVICE TYPE PERMANENT UNIT CHECK ON DISK 'mode (cuu) , ERROR (READIWRIT)ING lABEL eN DISK 'mode(cuu), CANNOT RECOMPUTE WITHOUT LOSS OF DATA. NO CHANGE INSUFFICIENT BLOCKS eN DISK TC SUPPORT CMS DISK STRUCTURE FILE fn ft fm CANNOT BE HANDLED WITH SUPPLIED PARAMETER LIST FORMAT WILL ERASE All FILES ON DISK 'mode(cuu)'. DO YOU WISH TO CONTINUE? (YESINO): ENTER DISK LABEL: DISK REMAINS UNCHANGED 'nnn' [CYLINDERSIFE-512 BLOCKS) FORMATTED ON DISK 'mode(cu~' FORMATTING DISK 'mode' DMSFRE159T DMSFRE160T DMSFRE161T DMSFRE162T DMSFRE163T DMSFRE164T DMSFRE165T DMSFRE166T DMSFRE167T INSUFFICIENT STORAGE AVAILABLE TO SATISFY DMSFREE REQUEST FROM addr INVALID DMSFREE CAll FECM addr INVALID DMSFRET CALI FEOM addr, ERROR NUMBER nn VITAL FREE STORAGE POINTERS DESTROYED (INTERNAL ERROR CODE nn), RE-IPL CMS [LOWIHIGH}-CORE USEE CHAIN HAS EEEN DESTROYED (INTERNAL ERROR CODE nn) {LOWIHIGH)-CORE NUCLEUS STORAGE POINTERS DESTROYED (INTERNAL ERROR CODE nn) CHAIN HEADER AT addr: xxxxxx xxxxxx xxxxxx xxxxxx UNEXPECTED ERROR IN FREE STORAGE MANAGEMENT ROUTINE (INTERNAL ERROR CODE nn). RE-IPL CMS FREE STORAGE MANAGE~ENT EREOR, INTERNAL CODE ERROR nn DMSGAM951E DMSGAM952E DMSGAM953E DMSGAM954E DMSGAM955E DMSGAM956E INVALID SVC nnw GAM/SP NOT INSTALLED VIRTUAL STORAGE SIZE TCO IAEGE FOR 'CMSGAM' SHARED SEGMENT TO LOAD AT nnnnnn 'CMSGAM' SHARED SEGMENT ERROR. MODULE ADDRESS FOR SVC nn IS ZERO 'CMSGAM' SHARED SEGMENT ERROR. IDENTIFIER INVALID FOR SVC nn 'CMSGAM' SHARED SEGMENT PAGING I/O ERRORS WITH cccccc INSUFFICIENT STORAGE FCR GAM/SF ANCHOR ELOCK DMSGEN006E DMSGEN095E DMSGEN110E DMSGEN111E DMSGEN141S DMSGEN7151 NO READ/WRITE [' A'] DISK ACCESSED [FOR 'fn ft'] INVALID ADDRESS 'address' CORRECT FORM IS: {EOSGENiCMSXGENICMSZEN} lOCATION (SEGNAME) (DOSGENICMSXGENICMSZGEN) FAILED DUE 'Ie lOAD ERRORS DOSGEN FAILED DOE TC SAVESYS ERRORS [DOSGENICMSXGENICMSZGEN} COMPLETE DMSGLB002W DMSGLE014E DMSGLB047E DMSGLB108S FILE 'fn ft [fm]' NCT FOUND INVALID KEYWORD 'function' NO FUNCTION SPECIFIED MORE THAN 8 LIERARIES SPECIFIED DMSGL0047E DMSGLC104S DMSGL0618E DMSGL0622E DMSGL0628E DMSGL0631E DMSGL0649E NO FUNCTION SPECIFIED ERROR Inn' READING FILE 'fn ft fm' FROM DISK NUCEXT FAILED INSUFFICIENT FREE STORAGE - NO TABLE MADE INVALID GLOBALV FUNCTION 'function' SETL/SETLP/SETLS CAN ONLY BE EXECUTED FROM AN EXEC 2 EXEC OR AS A CMS COMMAND EXTRANEOUS PARAMETEE 'parameter' DMSGND002W DMSGND021E DMSGND022E DMSGND070E FILE 'fn ft [fm]' NOT FOUND ENTRY POINT 'name' NeT FOUND NO DIRECTORY NAME SPECIFIED INVALID {PARAMETER 'parameter'IARGUMENT 'argument') DMSGBN002E DMSGBN003E DMSGRN007B DMSGRN048E DMSGRN054E DMSGRN078E [INPUTIOVERLAY] {FILE[ (S) ]IDA'!A SET} ['fn [ft [fm]]'] NOT FOUND INVALID OPTION 'option' FILE 'fn ft fm' [IS] NOT FIXED, 80 CHAR. RECORDS INVALID MODE 'mode' INCOMPLETE FIIEID SPECIFIED INVALID CARD IN READER {DECKIFILE 'cardimage'} DMSHEL529E DMSHEL545E DMSHEL561E DMSHEL640E 'subcommand' SUBCOMMAND IS ONLY VALID IN EDITING MODE MISSING OPERAND(S) CURSOR IS NOT ON A VALID DATA FIELD UNABLE TO ACCESS HElP DISK (cuu), RC=nn FROM ACCESS COMMAND DMSHLP003B DMSHLP104S DMSHLP109S DMSHLP250S DMSHLP251B DMSHLP252E INVALID OPTION 'option' ERROR Inn' READING FILE Ifn ft fm' FROM DISK VIRTUAL STORAGE CAPACITY EXCEEDED I/O ERROR OR DEVICE ERROR HELP PROCESSING ERROR, CODE nnn 'description' VALID OPTIONS ARE: DESC FORM tARM ALL 304 IBM VM/SP System Messages and Codes Df!S DMSHLP254E HELP CANNOT FIND THE INFORMATION YOU REQUESTED. IF NOT MISSPELLED, PLEASE ENTER 'EELP' FOR MENU SELECTION OR 'HELP HELP' FOR THE HELP COMMAND DMSHLP907T I/O ERROR ON FILE 'fn ft fm' DMSICP001E DMSICP002E DMSICP003E DMSICP006E DMSICP007E DMSICP038E DMSICP070E DMSICP075E DMSICP099E NO FILENAME SPECIFIED FILE 'filename' IOCP NOT FOUND INVALID OPTION 'option' NO READ/WRITE DISK ACCESSED FILE 'filename' IOCP IS NCT FIXED, 80 CEAR. RECORDS FILEID CONFLICT FOR DDNAME 'SYSIN' INVALID PARAMETER 'pa~amete~' [DEVICE] devicename INVALID FOR {INPU!IOUTPUT} CMS/DOS ENVIRONMENT AC~IVE DMSIDE003E DMSIDE056E DMSIDE070E DMSIDE104S INVALID OPTION 'opticn' FILE 'fn ft' CON~AINS INVALID RECORD FORMAT INVALID PARAMETER 'pa~ameter' ERROR Inn' READING FILE 'fn ft fm' FROM DISK DMSIFC002E DMSIFC007E DMSIFC023E DMSIFC070E DMSIFC104S DMSIFC825E DMSIFC826E DMSIFC8281 DMSIFC829W DMSIFC831E DMSIFC832S [INPUTI OVERLA Y] {FIIE[ (S) ]I DATA SET} [' fn [ft [fm]]'] NOT FOUND FILE 'fn ft fm' [IS] NOT FIXED, 80 CHAR. RECORDS NO FILETYPE SPECIFIED INVALID {PARAMETER 'pa~ameter'IARGUMENT 'argument'} ERROR Inn' READING FILE 'fn ft fm' FROM DISK 'CLEAR' IS VALID CNIY WHEN SPECIFIED BY ITSELF EREP TXTLIBS NOT FOUND CPEREP ZERO OR CLEAR EAS EEEN CCMPLETED ATTEMPTED 'ZERO' WAS SUPPRESSED. REQUIRES PRIVILEGE CLASS F MORE THAN 100 CHARS OF CPTIONS SPECIFIED SOFTWARE INCOMPATIBILITY AT THE CPEREP-EREP INTERFACE. CODE=nnn DMSIMA001E DMSIMA002E DMSIMA003E DMSIMA013E DMSIMA014E DMSIMA046E DMSIMA047E DMSIMA346E DMSIMA347E DMSIMA348E DMSIMA349E NO FILENAME SPECIFIED [INPUTIOVERLAY] {FILE[ (S) ]IDA~IA SET} ['fn [ft [fm]]'] NOT FOUND INVALID OPTION 'option' MEMBER 'name' NO! FOUND IN LIERARY '['fn ft fm'llibmane]' INVALID KEYWORD 'function' NO LIBRARY NAME SPECIFIED NO FUNCTION SPECIFIED ERROR 'nn' LOADING 'fn ft' {DISKI' fn ft '} ERROR Inn' LOADING LIERARY 'litname' ERROR Inn' SAVING LIERARY 'litname' INVALID LIBRARY 'litname' DMSINI079E DMSINI080E DMSINI081E DMSINI082E DMSINI083E DMSIN"I131S DMSINI147R DMSINI260T DMSINI606R DMSINI607R DMSINI608R DMSINI609R DMSINI610R DMSINI611R DMSINI612R DMSINI615R DMSINI640R DMSINI902T INVALID DEVICE ADDRESS - REEN~ER INVALID {CYLIBLK} NUMEER - REENTER INVALID REPLY - ANSWER "YES" OR "NO" IPL DEVICE ERROR - REENTEE NUCLEUS {CYLIBLK} SPECIFICATION UNACCEPTABLE, ERROR 'X' IPL DEVICE WRITE I/C ERROR IS THE SHARED {S-DISKIY-DISK} DIRECTORY TO BE USED WITH THIS SYSTEM? YES OR NO VIRTUAL MACHINE SIZE TCO SMALL TO IPL NON-SHARED COPY OF CMS SYSTEM DISK ADDRESS = cuu REWRITE THE NUCLEUS? {YES INC} IPL DEVICE ADDRESS = cuu NUCLEUS {CYLIBLK} ADDRESS = nnn ALSO IPL {CYLIELK} 07 {YESINO} VERSION IDENTIFICATICN INSTALLATION HEADING = Y - DISK ADDRESS = cuu HELP DISK ADDRESS = cuu IPL DEVICE READ I/C EREOR DMSINS098W CMS OS SIMULATION NO~ AVAILABLE DMSINS100W CMSSEG SYSTEM NAME 'name' NOT AVAILAELE DMSINS100W SHARED {SSTATIYSTAT} NOT AVAILABLE DMSINT015E {UNKNOWN {CP/CMSICMSICP} DMSITP141T DMSITP142T DMSITP143T DMSITP144T IINVAIID {CMSISUBSET} COMMAND exception EXCEPTION OCCURRED AT addr IN ROUTINE called exception EXCEPTION OCCURRED AT addr IN ROUTINE routine DURING 'SPIEl EXIT ROUTINE exception EXCEPTICN CCCURREI AT addr in SYSTEM ROUTINE called. exception EXCEPTION OCCURRED AT addr IN ROUTINE called WHILE 'UFDBUSY' = xx. IPL CMS AGAIN Appendix B. Message Summary Alphamerically by Message Identifier 305 mIS DMSITS098S DMSITS122S DMSITS13QS DMSITS135S DMSITS136T DMSITS137T DMSITS138T DMSITS139T DMSITS1qOT DMSITS1SqT CMS OS SIMULATION NCT AVAILABLE ERROR IN CALL TO routine FRO~ addr, ERROR CODE nnn (HEX xxxxxx) UNSUPPORTED SVC 203 CODE nn CALLED FBOM addr MAXIMUM SVC DEPTH 'nnnn' HAS EEEN EXCEEDED WITH CALL AT addr SVC CALL FROM addr ILLEGALLY RE-ENTERS INTSVC. RE-IPt CMS CALL TO routine FROM addr DESTROYED SYSTEM SAVE AREA. RE-IPL CMS 'DMSKEY' CALL FROM addr OVERFLOWS KEY STACK, WITH MAX DEPTH 7 'DMSKEY RESET' FROM addr UNDEBFLOWS KEY STACK routine ROUTINE CALLEI FROM addr DID DMSKEY WITH NO RESET SAVE AREA FOR SVC CALL FRCM addr CANNCT BE ALLOCATED DMSJOIS03E DMSJOI561E DMSJOI562E DMSJOIS64W DMSJOI575E DMSJOI585E TRUNCATED CURSOR IS NOT ON A VALID DATA FIELD OPTION 'CURSOR' VALID IN DISPLAY MODE ONLY EOF REACHED INVALID {JOINISPLITI~AESIVERIFYIZONE} COLUMNS DEFINED NO LINE(S) CHANGED DMSLBD003E DMSLBD029E DMSLBD065E DMSLBD066E DMSLBD070E DMSLBD221E DMSLBD3241 DMSLBD7041 INVALID OPTION 'option' INVALID PARAMETER 'parameter' IN THE CPTION 'option' FIELD 'option' OPTION SPECIFIED ~WICE 'option' AND 'option' ARE CONFLICTING OPTIONS INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} INVALID DATA SET NAME NO USER DEFINED {DLBIIFILEDEFIIAEELDEF}'s IN EFFECT INVALID CLEAR REQUEST DMSLBM001E DMSLBM002E DMSLBM002W DMSLBM003E DMSLBM013W DMSLBM01QE DMSLBM037E DMSLBM046E DMSLEMOQ7E DMSLBM056E DMSLBM070E DMSLBM10QS DMSLBM105S DMSLBM109S DMSLBM157S DMSLBM167S DMSLBM213W DMSLBM907T NO FILENAME SPECIFIED [INPUTIOVERLAY] {FILE[ (S) ]IDA~A SET} ('fn eft [fm]]'] NOT FOUND FILE 'fn ft [fm]' NCT FOUND INVALID OPTION 'option' {MEMBERIPHASE} 'name' NOT FOUND IN LIBRARY 'libname' INVALID KEYWORD 'function' [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY NO LIBRARY NAME SPECIFIED NO FUNCTIO~ SPECIFIED FILE 'fn ft [fm]' CONTAINS INVALID {NAMEIALIASIENTRYIESD} RECORD FORMATS INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} ERROR Inn' READING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK VIRTUAL STORAGE CAPACI~Y EXCEEDED MACLIB LIMIT EXCEEDED [, lAST MEMEER ADDED WAS 'membername'] PREVIOUS MACLIB FUNC~ION NOT FINISHED LIBRARY 'fn ft fm' NCT CREATED I/O ERROR ON FILE 'fn ft fm' DMSLBT001E DMSLBT002E DMSLBT002W DMSLBT003E DMSLBT013E DMSLBT01QE DMSLBTOQ6E DMSLBTOQ7E DMSLBT056E DMSLBT056W DMSLBT10QS DMSLBT105S DMSLBT106S DMSLBT213W NO FILENAME SPECIFIED [INPUT I OVERLAY] {FILE[ (S) ] I DA 'IA SET} [' fn [ft [fm]]'] NOT FOUND FILE 'fn ft [fm]' NeT FOUND INVALID OPTION 'option' MEMBER 'name' NO~ FOUND IN LIBRARY '['fn ft fm'llibmane]' INVALID KEYWORD 'function' NO LIBRARY NAME SPECIFIED NO FUNCTION SPECIFIED FILE 'fn ft [fm]' CONTAINS INVALID {NAMEIALIASIENTRYIESD} RECORD FORMATS FILE 'fn ft fm' CONTAINS INVALID [NAMEIALIASIENTRYIESD] RECORD FORMATS ERROR Inn' READING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK NUMBER OF MEMBER NA~ES EXCEEDS MAX 'nnnn'. FILE 'fn ft' NOT ADDED LIERARY 'fn ft fm' NOT CREATED DMSLDS002E DMSLDS003E DMSLDSOQ8E DMSLDS069E DMSLDS220R DMSLDS221E DMSLDS222E DMSLDS223E DMSLDS226E DMSLDS227W DMSLDS2291 DMSLDS231E [INPUTI OVERLAY] {FIIE[ (S) )I DATA SET} [' fn (ft [fm]]'] NOT FOUND INVALID OPTION 'option' INVALID MODE 'mode' DISK {'mode't 'cuu'I'volid'} NeT ACCESSED ENTER DATA SET NAME: INVALID DATA SET ~AME I/O ERROR READING 'data set name' FROM {'fm'IOSIDOS} DISK NO FILEMODE SPECIFIED NO DATA SET NAME ALLOiED WITH FREE OPTION INVALID EXTENT FCUND FOR 'datasetname~ ON 'fm' DISK NO MEMBERS FOUND I/O ERROR READING VTCC FROM {'fm'IOSIDOS} DISK 306 IBM VM/SP System Messages and Codes DMS DMSLDS2331 NO FREE SPACE AVAILABLE ON 'fm' DISK DMSLG!0021 FILE 'fn' TXTLIB NOT FCUND DMSLIC001E DMSLI0002E DMSLI00021 DMSLI0003E DMSLI0005E DMSLI0021E DMSLI0029E DMSLI0055E DMSLI0056E DMSLI0099E DMSLIC104S DMSLIC105S OMSLI0109S DMSLI0116S OMSLI0168S D"SLI0169S DMSLI0201W DMSLI0202W DMSLIC203W DMSLI0206W DMSLIC623S NO FILENAME SPECIFIED [INPUTIOVERLAY] {FIIE[ (S) ]lDATA SET) ('fn [ft [fm]]'] NOT FOUND FILE 'fn' TXTLIB NOT FOUND INVALID OPTION 'option' NO 'option' SPECIFIED ENTRY POINT 'name' NCT FOUND INVALID PAEAMETER 'pa~amete~' IN THE CPTION 'option' FIELD NO ENTRY POINT DEFINED FILE 'fn ft [fm]' CONTAINS INVALID (NAMEIALIASIENTRYIESD) EEeOED FORMATS CMS/DOS ENVIRONMENT NeT ACTIVE EREOR Inn' READING FILE 'tn tt tm' FROM DISK EEEOR Inn' WRITING FILE 'tn tt tm' ON DISK VIETUAL STORAGE CAPACITY EXCEEDED LOADER TABLE OVEEFLew PSEUDO REGISTER TABLE OVERFLOW ESDID TABLE OVERFLOW THE FOLLOWING NAMES ARE UNDEFINED: DUPLICATE IDENTIFIER 'identifier' "SET LOCATION COUNTER" NAHE 'name' UNDEFINED PSEUDO REGISTER ALIGNMENT ERRCR MODULE CANNOT BE LOADED AT LOCATION 'loCation' BECAUSE IT WOULD OVERLAY THE CMS NUCLEUS DMSLIC7401 EXECUTION BEGINS ••• DMSLI0907T I/O ERROR ON FILE 'fn ft fm' D"SLKD001E DMSLKD002E DMSLKD004W DMSLKD005E DMSLKD006E DMSLKD007E DMSLKD008W DMSLKD012W DPlSLKD016W DMSLKt070E NO FILENAME SPECIFIED [INPUT I OVERLAY] {FIIE[ (S) ] I tATA SET} (' fn [ft [fm]]'] NOT FOUND WARNING MESSAGES ISSUED NO 'option' SPECIFIED NO READ/WRITE ['A'] DISK ACCESSED (FOR 'fn ft'] FILE 'fn ft fm' [IS] NeT FIXEt, 80 CHAR. RECORDS ERROR MESSAGES ISSUED SEVERE ERROR MESSAGES ISSUED TERPlINAL ERROR MESSAGES ISSUED INVALID {PARAMETER 'pa~ameter'IARGUMENT 'argument'} DMSLLU003E DMSLLU006E DMSLLU070E DPlSLLU099E DMSLLU1055 DMSLLU303E INVALID OPTION 'option' NO READ/WRITE ['A'] DISK ACCESSED [FOR 'fn ft'] INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} CMS/DOS ENVIRONMENT NeT ACTIVE ERROR 'nn' WRITING FILE 'tn ft tm' ON DISK NO SYSxxx SATISFIES RECUEST DMSLOS004E DMSLOS013E DMSLOS073E DMSLOS089E {BOOK 'subl.book'IMODULE 'module'IPHASE 'phase'IPROCEDURE 'procedure'} NOT FOUND MEMBEE 'name' NOT FCUND IN LIERIRY '['fn ft fm'llitmane]' UNABLE TO OPEN FILE ddname {OPENICLOSE} ERROR CODE Inn' ON {fnISYSxxxITAPn} DPlSLST002E (INPUT I OVERLA Y] (FIIE[ (S) ] I DATA SET) (' fn [fn [fm]]' ] NOT FOUND D~SLST003E INVALID OPTION 'option' DMSLST037E [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY DMSLST048E INVALID MODE 'mode' DPlSLST066E 'option' AND 'option' ARE CONFLICTING OPTIONS DMSLST069E DISK {'mode'I'cuu'I'vclid'} NOT ACCESSED DMSLST070E INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} DPlSLST105S ERROR Inn' WRITING FILE 'tn ft fm' ON DISK DPlSMDF001E DMSMDP002E OMSMDF018E DMSMDP070E NO FILENAME SPECIFIED [INPUTIOVERLAY] {FIIE[(S) ]IIlATA SET} ['fn [ft [fm]]'] NOT FOUND NO LOAD MAP AVAILABLE INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} DMSMOt001E DMSMOD002E DMSMOD003E DMSMOD005E DMsMOr021E D!SMOD032E DMSMOIl037E NO FILENAME SPECIFIED [INPUT I OVERLAY J {PIIE[ (S) ] I DATA SET} [' fn [ft [fm]]'] NOT FOUND INVALID OPTION 'option' NO 'option' SPECIFIED ENTRY POINT 'name' NOT FOUND INVALID FILETYPE 'ft' [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY Appendix B. Message Summary Alphamerically by Message Identifier 307 DMS DMSMOD040E DMSMOD070E DMSMOD084E DMSMOD104S DMSMOD105S DMSMOD109S DMSMOD114E DMSMOD116S DMSMOD520E DMSMOD529E DMSMOD545E NO FILES LOADED INVALID {PARAMETEE 'parameter'lARGUMENT 'argument'} INVALID USE OF 'FROM' AND 'TO' OPTIONS EEROE 'nn' READING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK VIRTUAL STORAGE CAPACITY EXCEEDED 'fn ft fm' NOT LOADED; CMS/DOS ENVIRONMENT (NOT] ACTIVE LOADER TABLE OVERFLCW INVALID OPERAND : operand SUBCOMMAND IS ONLY VALID IN {DISPLAYIEDITING} MODE MISSING OPERAND(S) DMSMVE002E DMSMVE003E DMSMVE037E DMSMVE041E DMSMVE048E DMSMVE069E DMSMVE070E DMSMVE073E DMSMVE075E DMSMVE086E DMSMVE127S DMSMVE128S DMSMVE129S DMSMVE130S DMSMVE225I DMSMVE226I DMSMVE232E DMSMVE706I DMSMVE7081 [INPUTIOVERLAY] {FIIE[ (S) ]lDA'IA SET} ('fn (ft (fm]]'] NOT FOUND INVALID OPTION 'option' (OUTPUT] DISK 'mode [cuu]' IS READ/ONLY INPUT AND OUTPUT FILES ARE THE SAME INVALID MODE 'mode' DISK (' mode' I 'cuu' I 'valid '} NCT ACCESSED INVALID (PARAMETER 'parameter'IARGUMENT 'argument'} UNABLE TO OPEN FILE adname [DEVICE] devicename {INVAIIDIIIIEGAL} FOR {INPU'IIOUTPUT} INVALID DDNAME 'ddname' UNSUPPORTED DEVICE FOR ddname I/O ERROR ON INPUT AFTER READING nnn RECORDS: INPUT ERROR code ON ddname I/O ERROR ON OUTPUT WRITING RECORD NUMBER nnnn: OUTPUT EBROR code ON ddname BLOCKSIZE ON V FORMAT FILE ddname IS LESS THAN 9 PDS MEMBER 'membername' MOVED END OF PDS MOVE INVALID RECFM -- SPANNED RECORDS NOT SUPPORTED TERM INPUT -- TYPE NULL LINE FOR END OF DATA DISK FILE 'FILE ddname A1' ASSUMED FOR DDNAME 'ddname' DMSMVG089E {OPENICLOSE} ERROR CODE Inn' ON {fnISYSxxxITAPn} DMSNAM002E DMSNAM003E DMSNAM029E DMSNAM104S DMSNAM156E DMSNAM618E DMSNAM621E DMSNAM622E DMSNAM622W DMSNAM633E DMSNAM633W DMSNAM634E DMSNAM6351 DMSNAM637E FILE 'fn ft fm' NC'I FCUND INVALID OPTION 'option' INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD ERROR Inn' READING FILE 'fn ft fm' FRCM DISK (FROMIRECORD} 'nnn' NOT FOUND - FILE 'fn ft fm' HAS ONLY 'nnn' RECORDS NUCEXT FAILED BAD PLIST: NAMEFIND MUST BE INVOKED AS A NUCLEUS EXTENSION INSUFFICIENT FREE STORAGE FOR NAMEFIND INSUFFICIENT FREE S'IORAGE FOR NAMEFIND BUFFER, PROCESSING CONTINUES TOO MANY TAGS WERE ENCOUNTEREt. MAXIMUM IS 64 PER LINE RETURNED VALUES ~ERE TRUNCATED NO VALUE TO SEARCH FOR WAS SPECIFIED NO ENTRIES WERE FOUND THAT MATCHED YOUR SEARCH CRITERIA MISING VALUE FOR THE 'option' CPTION DMSNCF001E DMSNCP002E DMSNCP003E DMSNCP013E DMSNCP021E DMSNCP025E DMSNCP045E DMSNCP056E DMSNCP099W DMSNCP109S NO FILENAME SPECIFIED [INPUTIOVERLAY] {FIIE[ (S) ]ltATA SET} ['fn (ft [fm]]'] NOT FOUND INVALID OPTION 'option' MEMBER 'name' NOT FOUND IN LIERARY '('fn ft fm'llitmane]' ENTRY POINT 'name' NOT FOUND INVALID DATA IN 370X CCNTROI PRCGRAM UNSUPPORTED 370X CONTROL PROGRAM TYPE FILE 'fn ft [fm]' CONTAINS INVALID {NAMEIALIASIENTRYIESD} RECORD FORMATS GENERATION PARAMETERS INCOMPA'IIBLE WITH VM/SP VIRTUAL STORAGE CAPACITY EXCEEDED DMSNXD050E DMSNXt070E DMSNXD616W DMSNXD617E DMSNXD624W PARAMETER MISSING AFTER NUCXDROP INVALID ARGUMENT 'argument' 'name' DOES NOT EXIS~ ERROR CODE n FEOM DMSFBET WHILE UNLOAtING 'module name' MODULE NO NUCLEUS EXTENSIONS ARE LOADED DMSNXL001E DMSNXL070E DMSNXL104S DMSNXL589E DMSNXL618E DMSNXL619E DMSNXL622E NO FILENAME SPECIFIED INVALID ARGUMENT 'argument' ERROR In' READING FILE 'fn ft fm' FROM DISK MISSING FILEDEF FOR DDNAME ddname NUCEXT FAILED MODULE 'module name' NOT FOUND INSUFFICIENT FREE STORAGE 308 IBM VM/SP System Messages and Codes DMS DMSNXM070E INVALID PARAMETER "parameter' DMSNXM622E INSUFFICIENT FREE S!ORAGE (nn ENTRIES) DMSNXM6241 NO NUCLEUS EXTENSIONS ARE LCArEt DMSOPL089E {OPENICLOSE} ERROR CODE Inn' CN {fnISYSxxxITAPn} DMSOPL158E NO CMS/DOS PROCEDURE LIBRARY SUPPORT DMSOPT070E INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} DMSOPT099E CMS/DOS ENVIRONMENT NC! ACTIVE DMSOSE052E MORE THAN 100 CHARS OF OP!IONS SPECIFIED DMSOSR070E INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} DMSOVR014E DMSOVE047E DMSOVE104S DMSOVR109S INVALID KEYWORD 'function' NO FUNCTION SPECIFIED ERROR Inn' READING FILE 'fn ft fm' FROM DISK VIRTUAL STORAGE CAPACITY EXCEEDED DMSPDF088E UNSUPPORTED DTF TYPE 'dtftype' DMSPI0113S {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUTI DMSFI0145S INTERVENTION REQUIRED ON {PRINTERIPUNCH} (cuu) NOT ATTACHED DMSPOP002E DMSPOP003E DMSPOF047E DMSPOP104S DMSPCP105S DMSPOP620E {INPUTIOVERLAY} {FILE[ (S) JDATE SETINOTE} ;'fn [ft [fmJ]} NOT FOUND INVALID OPTION 'option' NO FUNCTION SPECIFIED ERROR Inn' READING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK RTABLE ERROR ON LINE 'nnn' - {NON-NUMERIC VALUE SPECIFIEDIINCORRECT NUMBER OF PARAMETERSIMISALIGNED FIELDIINVALID PROP USERID} DMSPOR014E DMSPOF047E DMSPOR070E DMSPCR105S DMSPOR513E DMSPOR626E DMSPQR627E INVALID KEYWORD 'function' NO FUNCTION SPECIFIED INVALID PARAMETER {PARAMETER 'parameter'IARGUMENT 'argument'} ERROR Inn' WRITING FILE 'fn ft fm' ON DISK UNKNOWN CP/CMS CCMMAND INVALID ACTION ROUTINE PARAMETER 'parameter' RESULT IS 'nnnn' EY!ES TOe LARGE FOR CP COMMAND BUFFER DMSPCW117S ERROR WRITING TO DISPLAY TERMINAL DMSPOW529E SUBCOMMAND IS ONLY VALID IN {DISPLAYIEDITING} MODE DMSPQU520E INVALID OPERAND : operand DMSPQU5531 EDITING FILE: fn ft fm DMSPQU577E FILE HAS BEEN CHANGED. USE QQUIT TO QUIT ANYWAY DMSPRE001E DMSPRE002E DMSPRE109S DMSPRE183E DMSPRE234E DMSPRE235E DMSPRE236E DMSPRE237E DMSPRE238E NO FILENAME SPECIFIED [INPUTIOVERLAY] {FILE[ (S) JIDATA SET} ['fn [ft [fm]]' J NOT FOUND VIRTUAL STORAGE CAPACITY EXCEEtED INVALID {CONTROLIAUX} FILE CONTROL CARD ERROR IN LOAD LIST FILE 'fn ft fm' [NC INPUT] ERROR tnt IN INPUT TEXT FILE 'fn ft [fm]' UNRESOLVED EXTERNAL REFERENCE(S) ENCOUNTERED DUPLICATE EXTERNAL SYMEOL(S) ENCOUNTERED PRELOADER PROCESSING ERROR DMSPRT002E DMSPRT003E DMSPRT008E DMSPRT013E DMSPRT029E DMSPRT033E DMSPRT039E DMSPRT044E DMSPRT048E DMSPRT054E DMSPRT062E DMSPRT069E DMSPRT070E DMSPRT104S DMSPRT123S [INPUTIOVERLAYJ {FILE[ (S) JltATA SET} ['fn [ft [fmJ]'] NOT FOUND INVALID OPTION 'option' DEVICE 'euu' {INVALID eR NONEXISTENTIUNSUPPORTED DEVICE TYPE} MEMBER 'name' NOT FOUND IN LIERARY '['fn ft fm'llibmaneJ' INVALID PARAMETER 'parameter' IN THE CPTION 'option' FIELD FILE 'fn ft fm' IS NC! A LIERARY NO ENTRIES IN LIERARY 'fn ft fm' RECORD LENGTH EXCEEDS ALLCWABIE MAXIMUM INVALID MODE 'mode' INCOMPLETE FILEID SPECIFIED INVALID [CHARICHARACTER] '[=I*lchar]' IN [OUTPUT] FILEID ['fn ft [fm]'] DISK {'mode'l 'cuu 'I 'valid '} NCT ACCESSED INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} ERROR Inn' READING FILE 'fn ft fm' FROM DISK ERROR Inn' {PRINTINGIFUNCHING} FILE 'fn ft fm' Appendix B. Message Summary Alphamerically by Message Identifier 309 DAS DMSPRV003E DMSPRVOOqE DASPRV006E DMSPRV031E DMSPRV070E DMSPRV097E DASPRV098E DMSPRV099E DMSPRV105S DMSPRV113S DMSPRV411S INVALID OPTION 'option' (BOOK 'subl.book'IMCDULE 'module'IPHASE 'phase'IPROCEDURE 'procedure l ) NOT FOUND NO READ/WRITE ['A'] DISK ACCESSED [FOR 'fn ft'] [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY INVALID (PARAMETER 'parameter'IARGU!ENT 'argument') NO 'SYSRES' VOLUME ACTIVE NO (PHASEIPROCEDURE) NAME SPECIFIED CMS/DOS ENVIRONMENT NOT ACTIVE ERROR Inn' WRITING FILE 'fn ft fm' ON DISK (modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUT) (cuu) NOT ATTACHED {INPUTIOUTPUT} ERROR CODE Inn' ON 'SYSxxx' DMSPUN002E DMSPUN003E DMSPUN008E DMSPUN013E DMSPUN033E DMSPUN039E DMSPUNOQ4E DMSPUN054E DMSPUN062E DMSPUN069E DMSPUN104S DMSPUN118S DMSPUN123S [INPUTIOVERLAY] {FIIE[ (~ ]IDATA SET) ['fn eft [fm]]'] NOT FOUND INVALID OPTION 'option' DEVICE 'cuu' (INVAllt CR NONEXISTENTIUNSUPPORTED DEVICE TYPE) MEMBER 'name' NOT FOUND IN LIERARY '['fn ft fm'llibmane]' FILE 'fn ft fm' IS NeT A IIERARY NO ENTRIES IN LIERARY 'fn ft fm' RECORD LENGTH EXCEEDS ALLOWABLE MAXIMUM INCOMPLETE FILEID SPECIFIED INVALID [CHARICHARACTEB] '[=I*lchar]' IN [OUTPUT] FILEID ['fn ft [fm]'] DISK {'mode'I'cuu'I'volid'} NOT ACCESSED ERROR Inn' READING FILE 'fn ft fm' FROM DISK ERROR PUNCHING FILE {'fn ft fa'} ERROR Inn' {PRINTINGIPUNCHING} FILE 'fn ft fm' DMSQRY005E DMSQRY014E DMSQRY026E DMSQRY047E DMSQRY070E DMSQRY099E DMSQRY3241 NO 'option' SPECIFIED INVALID KEYWORD 'function' INVALID PARAMETER 'parameter' FCR 'function' FUNCTION NO FUNCTION SPECIFIED INVALID {PARAMETER 'parameter'IARGU!ENT 'argument'} CMS/DOS ENVIRONMENT NOT ACTIVE NO USER DEFINED {DLEIIFILEDEFIIAEELDEF}'s IN EFFECT DMSRDC008E DMSRDC037E DMSRDC042E DMSRDC054E DMSRDC062E DMSRDC105S DMSRDC124S DMSRDC205W DMSRDC7011 DMSRDC1021 DMSRDC7381 DEVICE 'cuu' {INVALID OR NONEXISTENTIUNSUPPORTED DEVICE TYPE} [OUTPUT] DISK 'mode [cuu]' IS BEAD/ONLY NO FILEID(S) SPECIFIED INCOMPLETE FILEID SPECIFIED INVALID [CHARICHARACTER] '[=I*lchar]' IN [OUTPUT] FILEID ['fn ft [fm]'] ERROR Inn' WRITING FILE 'tn ft fm' ON DISK ERROR READING CARD FILE READER EMPTY OR NOT BEADY NULL FILE [READ CONTROL CARD MISSING. FOLLOWING ASSUMED:] :READ {fn ft fmlREADCARD C!SUT1 A1) RECORD LENGTH IS 'nnn' BYTES DMSRDR070E INVALID PARAMETER 'parameter' DMSRDR630S ERROR ACCESSING SPOCl FILE DMSREA830E I/O ERROR READING A RECORD FROM THE ERROR RECORDING CYLINDERS DMSRNM002E DMSRNM003E DMSRNM019E DMSRNM024E DMSRNM030E DMSRNM031E DMSRNM048E DMSRNM051E DMSRNM054E DMSRNM062E DMSRNM069E [INPUTIOVERLAY] (FIIE[ (S) ]ICATA SET) ['fn eft [fm]]'] NOT FOUND INVALID OPTION 'option' IDENTICAL FILEIDS FILE 'fn ft fm' ALREADY EXISTS [~- SPECIFY 'REPLACE'] FILE 'fn ft fm' ALREADY ACTIVE [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY INVALID MODE 'mode' INVALID MODE CHANGE INCOMPLETE FILEID SPECIFIED INVALID [CHARICHARACTER] '[=I*lchar]' IN [OUTPUT] FILEID ['fn ft [fm]'] DISK {'mode'l 'cuu'l 'volid') NCT ACCESSED DMSRRV003E DMSRRV004E DMSRRV006E DMSRRV010E DMSRRV091E DMSRRV098E DMSRRV099E DMSRRV105S DMSRRV113S DMSRRV411S INVALID OPTION 'option' {BOOK 'subl.book'IMODULE 'module'IPHASE 'phase'IPROCEDURE 'procedure'} NOT FOUND NO READ/WRITE ['A'] DISK ACCESSED [FOB 'fn ft'] INVALID (PARAMETER 'parameter'IARGUftENT 'argument') NO 'SYSRES' VOLUME ACTIVE NO {PHASEIPROCEDURE} NAME SPECIFIED CMS/DOS ENVIRONMENT NeT ACTIVE ERROR Inn' WRITING FILE 'fn ft fm' ON DISK {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUT) (cuu) NOT ATTACHED {INPUTIOUTPUT} ERROR CODE Inn' ON 'SYSxxx' 310 IBM VM/SP System Messages and Codes DMS DMSRUN001E DMSRUN002E DMSRUN048E DMSRUN070E DMSRUN999E NO FILENAME SF!CIFI!D [INPUTIOVERLAY] {PILE[ (S) ]IDA'!A SET} ['fn Eft [fm]]'] NOT POUND INVALID MODE 'mode' INVALID ARGUMENT 'argument' NO ft MODULE FCUND DMSSB~120S (INIOUT] PUT ERROR CODE Inn' ON 'ddname' DMSSCH520E DMSSCH525E DMSSCH529E DMSSCH545E DMSSCH551I DMSSCH561E DMSSCH569E DMSSCH574E DMSSCH586E INVALID OPERAND : o~erand INVALID PFKEY NUMBER SUBCOMMAND IS ONLY VALID IN {DISPLAY I EDITING} MODE MISSING OPERANI(S) STRING 'string' FOUND. --- PFnn SET FOR SELECTIVE CHANGE CURSOR IS NOT ON A VALID DA'!A FIELD NO 'CHANGE' OR 'CIOCATE' SUBCCMMAND SFECIFIED CHANGE NOT VALID {WITH CLOCATEIAFTER CURSOR MOVEMENT} NOT FOUND {ON SCREEN} I DMSSCR151E 3278 MOD 5 DISFLAY TERMINAL NeT SUPPORTED BY OLD CMS EDITOR DMSSCT120S {IN/OUT]PUT ERROR 'code' ON 'ddname' DMSSEB429I 'TAPn (cuu) , EOT CN OUTPUT DMSSEG403S filename SHAREI SEGMENT NOT AVAILABLE - RELOAD CMSDOS DMSSET014E DMSSET026E DMSSET031E DMSSET047E DMSSET048E DMSSET050E DMSSET061E DMSSET070E DMSSET098W DMSSET099E DMSSET100W DMSSET142S DMSSET333E DMSSET400S DMSSET401S DMSSET410S DMSSET444E INVALID KEYWORD 'function' INVALID PARAMETER 'parameter' FCR 'function' FUNCTION LOADER TABLES CANNO'! BE MODIPIED NO FUNCTION SPECIFI!D INVALID MODE 'mode' PARAMETER MISSING AFTER {EINAeEISYSxxxlfunction} NO TRANSLATION CHARAC'!ER SPECIPIED INVALID {PARAMETER 'parameter'IARGUftENT 'argument'} CMS OS SIMULATION NO'! AVAILABLE CMS/DOS ENVIRONMENT NCT ACTIVE SYSTEM NAME 'name' NO'! AVAILABLE SAVED SYSTEM NAME 'name' INVALID nnnnnK PARTITION TOC LARGE FOR 'IHIS VIRTUAL MACHINE SYSTEM 'sysname' DOES NOT EXIST VM SIZE (size) CANNO'! EXCEED 'sysname' START ADDRESS (address) CONTROL PROGRAM ERECR INDICATION 'retcode' VOLUME 'label' IS NCT A DOS SYSRES DMSSLN002E DMSSLN104S DMSSLN350E DMSSLN351E [INPUTIOVERLAY] {PILE[ (S) JIDA'IA SET} ['fn Eft [fm]]'] NOT FOUND ERROR Inn' READING FILE 'fn ft fm' FROM DISK MODULE IS MARKED NOT EXECUTABLE MODULE IS MARKED ONLY LOAIABLE DMSSMN109S VIRTUAL STORAGE CAPACITY EXCEEDED DMSSMN133S INVALID GETMAIN OR FREEMAIN SPECIFICATION DMSSOP036E OPEN ERROR CODE Inn' eN 'ddname' DMSSOP036W UPDATE REQUESTED FOR READ-ONLY DISK DMSSOP109S VIRTUAL STORAGE CAPACITY EXCEEDED DMSSOE520E INVALID OPERAND : o~erand DMSSPL561E DMSSPL562E DMSSPL575E DMSSFL585E DMSSPL586E CURSOR IS NOT ON A VALID EATA FIELD OPTION 'CURSOR' VALID IN DISPLAY MODE ONLY INVALID {JOINISPLITITAESIVERIFYIZONE} COLUMNS DEFINED NO LINE(S) CHANGED NOT FOUND DMSSPR002E DMSSPR014E DMSSPR026E DMSSPR113S DMSSPR145S DMSSPR1961 DMSSPE197S DMSSPR198E DMSSFR199E [INPUTIOVERLAY] {PILE[ (~]IDATA SET) ['fn [ft [fm]]'] NOT FOUND INVALID KEYWORD 'function' INVALID PARAMETER 'parameter' FOR 'function' FUNCTION {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUT} (cuu) NOT ATTACHED INTERVENTION RECUIRED eN {PRINTERIPUNCH} PRT cuu SETUP COMPL!TE UNDIAGNOSED ERROR FRCM PRINTER 'OOE' SETPRT CAUSED A LOA I CHECK - SNS=ssssssss PRT 'OOE' NOT A VIRTUAL 3800 Appendix B. Message Summary Alphamerically by Message Identifier 311 DMS DMSSPR204E TOO MANY WCGM'S NEEDED FOR 'CHARS' DMSSPR352E INVALID SETPR1 DATA IN FILE 'fn ft' DMSSRT002E DMSSRT009E DMSSRT019E DMSSRT034E DMSSRT037E DMSSRT053E DMSSRT054E DMSSRT062E DMSSRT063E DMSSRT069E DMSSRT070E DMSSRT104S DMSSRT105S DMSSRT212E DMSSRT604R [INPUTIOVERLAY] {FILE[ (S) ]lDA1A SET} ['fn Eft [fm]]'] NOT FOUND COLUMN 'col' EXCEEDS RECORD LENGTH IDENTICAL FILEIDS FILE 'fn ft fm' IS NO~ FIXED lENGTH [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY INVALID SORT FIELD PAIR DEFINED INCOMPLETE FILEID SPECIFIED INVALID [CHARICHARACTER] '[=I*lchar]' IN [OUTPUT] FILEID ['fn ft [fm]'] NO [SORTITRANSIATICNISFECIFICATION] LIST {ENTEREDIGIVEN) DISK {'mode'l 'cuu' I 'valid'} NOT ACCESSED INVALID {PARAMETER 'parameter'IARGUMENT 'argument') ERROR 'nn' READING FILE 'fn ft fm' FROM DISK ERROR 'nnw WRITING FILE 'tn ft tm' ON DISK MAXIMUM NUMBER OF RECORDS EXCEEDED ENTER SORT FIELDS: DMSSRV003E DMSSRV004E DMSSRV006E DMSSRV070E DMSSRV097E DMSSRV098E DMSSRV099E DMSSRV105S DMSSRV113S DMSSRV194S DMSSRV411S INVALID OPTION 'option' {BOOK 'subl.book'IMODULE 'module'IPHASE 'phase'IPROCEDURE 'procedure'} NOT FOUND NO READ/WRITE ['A'] DISK ACCESSED [FOR 'fn ft'] INVALID {PARAMETER 'Farameter'IARGUMENT 'argument') NO 'SYSRES' VOLUME AC~IVE' NO {PHASEIPROCEDURE) NAME SPECIFIED CMS/DOS ENVIRONMENT NOT ACTIVE ERROR Inn' WRITING FILE 'fn ft fm' ON DISK {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUTI (cuu) NOT ATTACHED BOOK 'subl.book' CONTAINS EAD RECORDS {INPUTIOUTPUT} ERROR CODE Inn' CN 'SYSxxx l DMSSSK070E DMSSSK362E 'DMSSSK363E DMSSSK364E DMSSSK365E DMSSSK400S DMSSSK410S INVALID {PARAMETER 'parameter'IARGUMENT 'argument') INVALID STORAGE PROTECT KEY 'key' INVALID STARTING ADDRESS 'startadr' VM STORAGE NOT LARGE ENOUGH TC CONTAIN SYSTEM LOADING AT startadr to endadr SYSTEM NAME NOT SPECIFIED SYSTEM 'sysname' DOES NOT EXIST CONTROL PROGRAM ERROR INDICATION 'retcode' DMSSTA024E FILE 'fn ft fm' ALREADY EXISTS [-- SPECIFY 'REPLACE'] DMSSTA520E INVALID OPERAND : operand DMSSTA7031 FILE 'fn ft [fro]' {COFIEDICREATED} DMSSTG109S VIRTUAL STORAGE CAPACITY EXCEEDED DMSSTG133S INVALID GETMAIN OR FBEERAIN SPECIFICATION DMSSTT002E DMSSTT048E DMSSTT054E DMSSTT062E DMSSTT069E DMSSTT070E DMSSTT227I DMSSTT2281 DMSSTT229E DMSSTT253E [INPUTIOVERLAY] (FILE[ (S) ]IDATA SET) ['fn [ft [fm]]'] NOT FOUND INVALID MODE 'mode' INCOMPLETE FILEID SPECIFIED INVALID [CHARICHARACTER] '[=I*lchar]' IN (OUTPUT] FILEID ['fn ft [fm]'] DISK {t mode' I 'cuu' I 'vclid') NOT ACCESSED INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} PROCESSING VOLUME 'no' IN DATA SET 'data set name' USER LABELS BYPASSED ON DATA SE~ 'data set name' UNSUPPORTED OS DATA SET r [EBROB 'code'] FILE fn ft fm CANNOT BE HANDLED iITH SUPPLIED PARAMETER LIST DMSSVT033E FILE 'fn ft UNSUPPORTED DMSSVT120S {INIOUT)PUT DMSSVT121S UNSUPPORTED D~SSVT119S fm' IS NCT A LIERARY FORM OF {'macro'l 'parmI) (MACROISVC) ERROR 'code' ON 'ddname' SVC svc (HEX xx) CALLED FROM addr DMSSYN002E [INPUTIOVERLAY] {FILE[ (S) ]IDA'1A SET) ['fn [ft [fm]]'] NOT FOUND DMSSYN003E INVALID OPTION 'option' D~SSYN007E FILE 'fn ft fm' [IS] NOT FIXED r 80 CHAR. RECORDS DMSSYN032E INVALID FILETYPE 'ft' DMSSYN056E FILE 'fn ft [fro]' CONTAINS INVALID {NAMEIALIASIENTRYIESD} RECORD FORMATS DMSSYN066E 'option' AND 'option' ARE CONFLICTING OFTIONS DMSSYN104S ERROR Inn' READING FILE 'fn ft fm' FROM DISK DMSSYN7111 NO SYSTEM SYNONYMS IN EFFECT DMSSYN7121 NO SYNONYMS. (DMSINA NOT IN NUCLEUS) DMSTLB027E INVALID DEVICE {'device name'I'device' FOB 'SYSxxx'} 312 IBM VM/SP System Messages and Codes DflS DKSTLE043E DKSTLB058E DKSTLB110S DKSTLE111S DKSTLB113S DKSTLE421E DMSTLE422E DKSTLB4231 DMSTLB424E DKSTLB425R DKSTLB426R DMSTLB4271 DMSTLB4281 DMSTLB430E DKSTLB431E DMSTLB432E DMSTLB433R DMSTLE434E DKSTLB435R DMSTLB4361 DMSTLB4371 'TAPn(cuu}, IS FILE PROTECTED END-OF-FILE or END-OF-TAPE[[ON 'TAPn']] ERROR READING 'TAPn {(cuu})' ERROR WRITING 'TAPn (cuu)' {modeiDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUT} (cuu) NOT ATTACHED 'TAPn (cuu) , HDR1 LAEEL KISSING FOR 'filename' 'TAPn (cuu) , POSITIONED WRONG FOR 'filename' 'TAPn (cuu) , POSITIONED PARAMETER IGNORED. OUTPUT FILE WILL BE WRITTEN IMMEDIATELY AFTER NEW VOL1 LAEEL 'TAPn (cuu) , NOT POSITIONED AT EOF1 LABEL 'TAPn (cuu) , BLOCK COUNT ERROR FOR 'filename' ENTER 'IGNORE' OR 'CANCEL' 'TAPn (cuu) , UNEXPIRED FIlE ENTER 'IGNORE' OR 'ERROR' 'TAPn (cuu) , EOV1 LAEEL READ 'TAPn (cuu)' EOV1 LABEL WRITTEN 'TAPn (cuu) , LABELDEF INFORMATICN MISSING FOR FILE 'filename' 'TAPn (cuu) , VOL1 LABEL MISSING 'TAPn (cuu) , VOLID volid tOES NCT MATCH LABELDEF VOLID FOR 'filename' ENTER 'WRITE (VOLID' CR 'EEJECT' 'TAPn (cuu) , INPUT LABEL CHECK ERROR FOR FILE 'filename' ENTER 'IGNORE' OR 'CANCEL' 'TAPn (cuu) , MISSING USER STANDARD LABEL FOR 'ddname' 'TAPn (cuu)' NSL ROUTINE EETUFNED AN ERROR CODE 'nnnnnn' FOR 'filename' DKSTMA001E DMSTMA003E DMSTMA057E DMSTMA070E DMSTMA105S DMSTMA109S DKSTMA110S DKSTMA137S DMSTMA138S DKSTMA139S DMSTMA420E NO FILENAME SPECIFIED INVALID OPTION 'option' INVALID RECORD FCEMAT INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} ERROR 'nn' WRITING FILE 'fn ft fm' ON DISK VIRTUAL STORAGE CAPACITY EXCEEDED ERROR READING 'TAPn {(cuu)}' ERROR 'nne ON STATE FOR 'fn ft fm' ERROR nn ERASING fn ft BEFORE LCADING TAPE TAPE FILE EXCEEDS 9 CMS MACLIBS NSL EXIT FILENAME MISSING OR INVALID DMSTPD003E DMSTPD058E DMSTPD105S DMSTPD109S DMSTPD110S DKSTPD420E DMSTPD7031 DKSTPD7071 INVALID OPTION 'option' END-OF-FILE OR END-CF-TAPE [ON 'TAPn'] ERROR Inn' WRITING FILE 'fn ft fm' ON DISK VIRTUAL STORAGE CAPACITY EXCEEDED ERROR READING 'TAPn {(cuu)}' NSL EXIT FILENAME MISSING OR INVALID FILE 'fn ft [fm]' {COPIEDICREATED) TEN FILES COPIED DMSTPE002E DKSTPE003E DMSTPE010E DMSTPE014E DMSTPE017E DMSTPE023E DMSTPE027E DMSTPE029E DMSTPE037E DMSTPE042E DMSTPEOQ3E DMSTPE047E DKSTPE048E DMSTPE057E DMSTPE058E DMSTPE070E DMSTPE096E DMSTPE104S DMSTPE105S DMSTPE110S DMSTPE111S DMSTPE113S DMSTPE115S (INPUTIOVERLAY) (FILE[ (5) )IDATA SET) ['fn eft [fm]]'] NOT FOUND INVALID OPTION 'option' PREMATURE EOF ON FILE 'fn ft [fm]' INVALID KEYWOBD 'function' INVALID DEVICE ADDRESS 'cuu' NO FILETYPE SPECIFIED INVALID DEVICE {'deviCE name'I'device' FOR 'SYSxxx'} INVALID PARAMETER 'parameter' IN THE OPTION 'option' FIELD [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY NO FILEID(S) SPECIFIED 'TAPn(cuu), IS FILE PROTECTED NO FUNCTION SPECIFIED INVALID MODE 'mode' INVALID RECORD FORMAT END-OF-FILE OR END-OF-TAPE [ON 'TAPn') INVALID {PARAMETER 'parameter'IARGUMENT 'argument'} FILE 'fn ft' DATA BLOCK CCUNT INCORRECT ERROR Inn' READING FILE 'fn ft fm' FROM DISK ERROR 'nnw WRITING FIll 'fn ft fm' ON DISK ERROR READING 'TAPn {(cuu)]' ERROR WRITING 'TAPn (cuu) , {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUT} (cuu) NOT ATTACHED {CONVERSIONI {719]-TRACKI{80016250] BPIITRANSLATIONIDUAL-DENSITY] FEATURE NOT SUPPORTED ON DEVICE 'cuu' DMSTPE431E'TAPn (cuu) , VOL1 LABEL MISSING DMSTPE7011 NULL FILE DKSTYP002E [INPUTI OVERLAY J {FILE[ (S) ]I DATA SET} [. fn (ft [fm]]I] NOT FOUND DKSTYP003E INVALID OPTION 'option' Appendix B. Message summary Alphamerically by Message Identifier 313 DMS DMSTYP005E DMSTYP009E DMSTIP013E DMSTYP029E DMSTYP033E DMSTYP039E DMSTYPOQ9E DMSTYP054E DMSTYP062E DMSTYP069E DMSTYP104S NO 'option' SPECIFIED COLUMN 'col' EXCEEDS RECORD LENGTH MEMBER 'name' NOi FOUND IN LIERARY '['fn ft fm'llibmaneJ' INVALID PARAMETER 'parameter' IN THE CPTION 'option' FIELD FILE 'fn ft fm' IS NOT A LIERARY NO ENTRIES IN LIERARY 'fn ft fm' INVALID LINE NUMBER 'line number' INCOMPLETE FILEID SPECIFIED INVALID [CHARICHARACT~F] '[=I*lchar]' IN [OUTPUT] FILEID ['fn ft [fmJ'J DISK {'mode'l 'cuu'I'volid'} NOi ACCESSED ERROR 'nn' READING FILE Ifn ft fm' FRCM DISK DMSUPD001E DMSUPD002E DMSUPD003E DMSUPD007E DMSUPD010W DMSUPD024E DMSUPD037E DMSUPD048E DMSUPt065E DMSUPD066E DMSUPD069E DMSUPD070E DMSUPD104S DMSUPD10SS DMSUPD174W DMSUPD176W DMSUPD1771 DMSUPD1781 DMSUPD179E DMSUPD180W DMSUPD181E DMSUPD182W DMSUPD183E DMSUPD184W DMSUPD185W DMSUPD186W DMSUPD187E DMSUPD207W DMSUPD210W DMSUPD299E DMSUPD300E DMSUPD3041 NO FILENAME SPECIFIED [INPUTIOVERLAY] {FIIE[(S) ]ltATA SET} ['fn eft [fm]]'J NOT FOUND INVALID OPTION 'option' FILE 'fn ft fm' [IS] NeT FIXED, 80 CHAR. RECORDS PREMATURE EOF ON FILE 'fn ft fm' -- SEQ NUMBER ••••••••• , NOT FOUND FILE 'fn ft fm' ALREADY EXISiS [-- SPECIFY 'REPLACE'] [OUTPUTJ DISK 'mode [cuu]' IS READ/ONLY INVALID MODE 'mode' 'option' OPTICN SPECIFIED TWICE 'option' and 'option' ARE CONFLICTING OPTIONS DISK {'mode'l 'cuu'l 'valid'} NeT ACCESSED INVALID (PARAMETER 'parameter'IARGUMENT 'argument') ERROR 'nn' REAtING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK SEQUENCE ERROR INTRODUCED IN OUTPUT FILE: , •••••••• , TO , •••••••• , SEQUENCING OVERFleW FCILOWING SEQ NUMfER , •••••••• , WARNING MESSAGES ISSUED (SEVEBliY = nn). {'REP' OPTION IGNORED} UPDATING 'fn ft fm' APPLYING 'fn ft fm' {[APPLYING 'fn ft fm'J} MISSING OR DUPLICATE 'MACS' CARD IN CCNTROL FILE 'fn ft fm' ~ISSING PTF FILE 'fn ft fm' NO UPDATE FILES WERE FCUNt SEQUENCE INCREMENT IS ZERO INVALID {CONTROLIAUX} FILE CCNTEOL CARD './ S' NOT FIRST CARD IN UPDATE FILE -- IGNORED {INVALIDINON NUMERIC} CHARACTER IN SECUENCE FIELD , •••••••• SEQUENCE NUMBER [' ••••••••• ] NOT FOUND OPTION 'STK' INVALID WITHOUi 'CiL' INVALID UPDATE FIlE CeNTReL CARt INPUT FILE SEQUENCE ERROR , ••••••••• TO , •••••••• INSUFFICIENT STORAGE TC CCMPLETE UPDATE INSUFFICIENT STORAGE iO BEGIN UPDATE UPDATE PROCESSING WILL EE DONE USING tISK DMSUTL003E DMSUTL014E DMSUTL024E DMSUTL032E DMSUTI039E DMSUTLOQ2E DMSUTL047E DMSUTL054E DMSUTL065E DMSUTL066E DMSUTL073E DMSUTL901T DMSUTL907T INVALID OPTION 'option' INVALID KEYWORD 'function' FILE 'fn ft fm' ALREADY EXIS~S [-- SPECIFY 'REPLACE'] INVALID FILETYPE 'ft' NO ENTRIES IN LIERARY 'fn ft fm' NO FILEID(S} SPECIFIED NO FUNCTION SPECIFIED INCOMPLETE FILEID SPECIFIED 'option' OPTION SPECIFIED TWICE 'option' AND 'option' ARE CONFLICTING OPTIONS UNABLE TO OPEN FILE ddname UNEXPECTED ERROR AT 'addr': PIIST 'plist fn ft fm' AT addr, BASE addr, RC nn I/O ERROR ON }'ILE 'fn ft fm' DMSVGN069E DMSVGN360E DMSVGN3601 DNSVGN360R DMSVGN361E DMSVGN361I DMSVGN3621 DMSVGN362R DMSVGN3631 DMSVGN363R DMSVGN36QI DMSVGN364R DMSVGN3651 DMSVGN36SR DISK {'mode" 'cuu'I'volid'} NeT ACCESSED INVALID RESPONSE 'response' CMS/VSAM TEXT FILES CBEATED ON DISK 'A' ENTER EITHER 'INSTALL' OR 'UPDATE' DISK 'mode' IS NOT A {CMSIDCS} DISK CREATING CMS TEXT FILES ••• LINK EDITING sysname ENTER MODE OF DOS SYSTEM REIOCATABLE LIBRARY DISK: sysname DOSLIB CREATED ON DISK 'A' ENTER LOCATION WHERE sysname WILL BE LOADED AND SAVED: FETCHING sysname ••• ENTER 'CMSVSAM' OR 'CMSSAMS' CR 'BOTH' FOR GENERATION OF NEW SYSTEM(S): SYSTEM sysname SAVEn ONE OR MORE OF THE TEXT FILES LISTED IN THE fn EXEC 314 IBM VM/SP System Messages and Codes D.HS DMSVGN366E DMSVGN3661 DMSVGN366R DMSVGN3671 DMSVGN3681 DMSVGN368R DMSVGN369E DMSVGN369R DMSVGN371R DMSVGN380R DMSVGN381R DNSVGN382R ARE MISSING. THE VSAM PP PID TAPE SHOULD BE ON TAPE DRIVE 181, ENTER: 'GO' IF TAPE ERIVE IS READY TO LOADFILE OR 'QUIT' TO STOP GENERATION PROCESS NO CMS/DOS SUPPORT FCB NATIVE 3380 DISK STARTING TO READ PTF DECKS FRCM READER ••• ENTER NAME OF SYSTEM TO BE SAVED: 'modulename TEXT' WBITTEN ON DISK 'A' count MODULES HAVE EEEN RESTO FEE ERASE sysname DOSLIB? •• ENTER 'YES' OR 'NO': INVALID RELEASE 31 OB LATER RECUIRED ENTER RELEASE NUMBER OF TAPE FILES TO BE PROCESSED: 'sysname' IS LOADED. ENTER CP MCDE TO APPLY ZAPS, ELSE 'NULL' ENTER 'TAPE' OR 'CARDS' FOR PTF APPLICATION: ENTER 'SELECT' OR 'ALI' FCR TAEE PTF APPLICATION: ENTER NUMBER OF TAPE FILES TO BE PROCESSED: DMSVIB109S DMSVIB400S DMSVIB401S DMSVIB410S VIRTUAL STORAGE CAPACITY EXCEEDED SYSTEM 'sysname' DOES NOT EXIST VM SIZE (size) CANNCT EXCEEE 'sjsname' START ADDRESS CONTROL PROGRAM ERROR INDICATION 'retcode' (address) DMSVIP109S VIRTUAL STORAGE CAPACITY EXCEEDED DMSVIP230E NO. OF VSAM EXIT ROUTINES HAS EXCEEDED MAX OF 128 - UNABLE TO CONTINUE DMSVLT089E {OPENICLOSE} ERROR CODE 'nn' ON {fnISYSxxxITAPn} DMSVMF006E DMSVMF035E DMSVMF047E DMSVMF058E DMSVMF070E DMSV.HF104S DMSV.HF105S DMSVMF109S DMSVMF110S DMSVMF113S DMSVMF117S DMSVMF383R NO READ/WRITE ['A'] DISK ACCESSED [FOR 'fn ft'] INVALID TAPE .HODE NO FUNCTION SPECIFIED END-OF-FILE OR END-CF-TAPE [ON 'TAPn'] INVALID {PARA.HETER 'paLameter'IARGU.HENT 'argument'} ERROR Inn' READING FILE 'fn ft fm' FRCM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK VIRTUAL STORAGE CAPACITY EXCEEDED ERROR READING 'TAPn {(cuu)}' {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUTI ERROR WRITING TO DISELAY TERMINAL APPLY Ifni? ••• ENTER 'NO' OR EOE: DMSVPD070E DMSVPD105S DMSVPD109S DMSVPD110S DMSVPD113S DMSVPD3671 DMSVPD3681 DMSVPD383R INVALID {PARAMETER 'paLameter'IARGU.HENT 'argument'} ERROR Inn' WRITING FILE 'fn ft fm' ON DISK VIRTUAL STORAGE CAPACITY EXCEEDED ERROR READING 'TAPn {(cuu)}' {modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUTI 'modulename TEXT' WRITTEN ON DISK 'A' count MODULES HAVE EEEN RESTCEEE APPLY Ifni? ••• ENTER 'NO' OR EOE: (cuu) NOT ATTACHED (cuu) NOT ATTACHED DMSWDC651E DISCARD MUST BE ISSUED FEOM RDRIIST, PEEK OR FILELIST DMSWDC652E MISSING OPERAND(S). SPECIFY EXECUTE [n] DISCARD DMSWDC653E ERROR EXECUTING 'command', RC=nn DMSWDF014E DMSWDF029E DMSWDF637E DMSWDF641E DMSWDF642E DMSWDF653E INVALID KEYWORD 'function' INVALID PARAMETER 'paLameter' IN THE OPTION 'option' FIELD MISSING VALUE FOR THE FROFILEIFEOMIFOBINOTEBOOK OPTION NO {COMMANDIOFTIONS} SPECIFIED} DEFAULTS DOES NOT ACCEPT {'command' COMMANDI 'option' OPTION FOR 'command'} ERROR EXECUTING 'GLeEAIV', BC=nn DMSWEX526E DMSWEX561E DMSWEX651E DMSWEX654E OPTION 'CURSOR' VALID IN DISPLAY MODE ONLY CURSOR IS NOT ON A VALID DATA FIELD 'EXECUTE' MUST BE ISSUED FROM FILELIST OR RDBLIST INVALID SYMBOL 'sjmnol' {I/O' MUST BE SPECIFIED ALONEIINVALID CHARACTER 'char' FOLLOWING ' / ' SYMBOL} DMSWFL002E DMSWFL003E DMSWFL054E DMSWFL062E DMSWFL070E DMSWFL637E DMSWFL651E DMSWFL680E FILE 'fn ft fm' NOT FOUND INVALID OPTION 'option' INCOMPLETE FILEID SPECIFIED INVALID CHARACTER 'character' IN FILEID 'fn ft' INVALID PARAMETER 'paLameteL' MISSING VALUE FOR THE 'PROFILE' OPTION 'APPEND' MUST BE ISSUED FROM RDRLIST CR FILELIST INVALID FILEID SPECIFIED WITH 'FILELIST' OPTION Appendix B. Message Summarj Alphamericallj by 8essage Identifier 315 DMS DMSWNM645W DMSWNM649E DMSWNM656E DMSWNM657E DMSWNM658W DMSWNM660E DMSWNM660W DMSWNM662E DMSWNM663W DMSWNM664E THE USER TAG NAME 'tagna~e' IS TCO tCNG TO DISPLAY ON THE PANEL EXTRANEOUS PARAMETER 'value' ERROR SEARCHING YOUR NAMES FILE. RC=nn FROM NAMEFIND COMMAND UNDEFINED PFKEY THE VALUE FOR THE 'tag' TAG IS TCO LCNG TO DISPLAY ON THE PANEL THE NICKNAME FIELD MUST BE FILLED IN WARNING: THIS ENTBY DUPLICATES AN EXISTING NICKNAME YOU ARE NOT ON AN ENTRY. PRESS PF 5, 7 OR 8 TO MOVE TO AN ENTRY THERE {IStARE} nn UNDISPLAYED TAG(S) {ENTRYtPREVIOUS ENTRYtNEXi ENTRY} NOT FOUND DMSWNT003E DMSWNT006E DMSWNT062E DMSWNT637E DMSWNT647E DMSWNT648E DMSWNT651E DMSWNT665E DMSWNT666E DMSWNT667E DMSWNT668E DMSWNT669E DMSWNT670E INVALID OPTION 'option' NO READ/WRITE DISK ACCESSED INVALID CHARACTER 'character' IN FILEID 'fn ft' MISSING {VALUEt'value'} FOR THE {'option' OPTIONt'operand' OPERAND} USERID NOT SPECIFIED FCR 'nickname' IN 'userid NAMES' FILE USERID 'name' NOT FCUND. CHECR THE 'userid NAMES' FILE {'CANCEL't'ADD'} MUST BE ISSUED FROM NOTE FILE 'USERID NOTE *' NOT FOUND. TO BEGIN A NEW NOTE ENTER 'NOTE name' FILE 'USERID NOTE *' ALREADY EXISTS. ENTER 'NOTE' TO CONTINUE OR SPECIFY 'REPLACE' OPTION NOTE HEADER DOES NOT CCNTAIN THE {KEYWORD {'FROH't 'TO'}t'OPTIONS' LINEt'DATE' LINE} 'ADD' OPTION MUSi BE SPECIFIED ALONE LIST OF ADDRESSEES CANNOT BEGIN WITH ICC:' NO NAMES TO BE ADDEt WERE FCUND DMSWPK003E DMSWPK029E DMSWPK062E DMSWPK132S DMSWPK156E DMSWPK630S DMSWPK637E DMSWPK643E DMSWPK644E DMSWPK649E DMSWPK650E DMSWPK655E DMSWPK672E DMSWPK674E INVALID OPTION 'option' INVALID PARAMETER 'parameter' IN THE CPTION 'option' FIELD INVALID CHARACTER 'character' IN FILEID 'fn ft' FILE IS TOO LABGE FROM 'nnn' NOT FOUND - THE FILE HAS ONLY 'nnn' RECORDS ERROR ACCESSING SpeCl FILE MISSING VALUE FOR THE {PRCFILEtFROMtFOR} OPTICN NO CLASS 'class' FILES IN YeUR EEADER ALL READER FILES ARE IN HOLD STATUS OR NOT CLASS 'class' EXTRANEOUS PARAMETEF 'value' INVALID SPOOIID 'nnnn' SPOOLID 'nnnn' DOES NCT EXIST VIRTUAL READER INVALID OR NOT DEFINED READER IS NOT READY DMSWRC003E DMSWRC006E DMSWRC024E DMSWRC037E DMSWRC062E DMSWRC069E DMSWRC630S DMSWRC637E DMSWRC643E DMSWRC644E DMSWRC649E DMSWRC650E DMSWRC655E DMSWRC671E DMSWRC672E DMSWRC674E DMSWRC681E DMSWRC682E INVALID OPTION 'option' NO READ/WRITE DISK ACCESSED FILE 'fn ft fm' ALREADY EXISTS DISK 'mode' IS ACCESSED AS READ ONLY INVALID CHARACTER '*' IN FIIEID 'tn ft fm' DISK 'mode' NOT ACCESSED ERROR ACCESSING SPOOL FILE MISSING VALUE FOR THE 'NOTEEOCR' OPTICN NO CLASS 'class' FILES IN YCUR READER ALL READER FILES ARE IN HCLD STATUS OR NOT CLASS 'class' EXTRANEOUS PARAMETER 'value' INVALID SPOOLID 'nnnn' SPOOLID 'nnnn' DOES NOT EXIST ERROR RECEIVING FILE 'fn ft fm', RC=nn FROM 'command' VIRTUAL READER INVLAID OR NOT DEFINED READER IS NOT READY THIS IS AN UNNAMED FILE. SPECIFY FILENAME AND FILETYPE ERROR COPYING FILE 'fn tt fm', RC=nn FBOM 'command' DMSWRL003E DMSWRL062E DMSWRL205E DMSWRL637E DMSWRL649E DMSWRL651E INVALID OPTION 'option' INVALID CHARACTER 'character' IN FILEID 'fn ft' NO FILES IN YOUR READER MISSING VALUE FOR THE 'PROFILE' CPTICN EXTRANEOUS PARAMETER 'value' 'APPEND' MUST BE ISSUED FRCM RDRLIST CR FILELIST DMSWSF002E DMSWSF003E DMSWSF006E DMSWSF048E DMSWSF054E DMSWSF062E DMSWSF069E FILE 'fn ft fm' NOT FOUND INVALID OPTION 'option' NOR READ/WRITE DISK ACCESSED INVALID MODE 'mode' INCOMPLETE FILEID SPECIFIED INVALID CHARACTER '*' IN EILEID 'fn ft fm' DISK 'mode' NOT ACCESSED 316 IBM VM/SP System Messages and Codes DKS DMSWSF081E DMSWSF637E DMSWSF647E DMSWSF648E DMSWSF657E DMSWSF667E DMSWSF671E DMSWSF672E DMSWSF673E DMSWSF674E DMSWSF675E DMSWSF676E DMSWSF677E DMSWSF678E DMSWSF679E DMSWSF680E INVALID REPLY - ANSWER "YES" OR "NO" MISSING NODEID FOR THE 'A~' OPERAND USERID NOT SPECIFIED FOR 'nickname' IN 'userid NAMES' FILE USERID 'name' NO~ FOUND. NO FILES HAVE BEEN SENT UNDEFINED PFKEY NOTE HEADER DOES NO~ CONTAIN ~HE {KEYWORD 'FROM'I'TO')I'OPTIONS'I'DATE' LINE} ERROR SENDING FILE 'fn ft fm', EC=nn FRCM 'command' VIRTUAL PUNCH INVALID OR NOT DEFINED ADDRESSEES ARE IN THE NOTE HEADER CARDS, DOS NOT SPECIFY NAME WITH THE NOTE OPTION PUNCH IS NOT READY NO NAMES SPECIFIED INVALID CHARACTER '*' FOR NE~~ORK ID INVALID OPTION 'option' IN CPTICN LINE INVALID NOTE HEADER FORMA~. NO~E CANNOT BE SENT (DISK 'mode' IS READ/ONLYIDISR 'mode' IS FULL) NOTE CANNOT BE SENT INVALID FILEID SPECIFIED WITH 'FILELIST' CPTICN DMSWTL637E DMSWTL647E DMSWTL648E DMSWTL676E MISSING NODEID FOR ~HE 'AT' CPERAND USERID NOT SPECIFIED FOR 'nickname' IN 'userid NAMES' FILE USERID 'name' NOT FCUND. NC MESSAGE HAS BEEN SENT INVALID CHARACTER '*' FOR NETWORK ID DMSXBG109S VIRTUAL STORAGE CAPACITY EXCEEDED DMSXCG5011 DMSXCG502W DMSXCG503E DMSXCG504E DMSXCG505E DMSXCG5061 DMSXCG509W DMSXCG511E DMSXCG517I DMSXCG518E DMSXCG520E DMSXCG5221 nn LINES DELETED NO LINE TO RECOVER TRUNCATED nn LINE(S) TRUNCATED NOT EXECUTED: THE TARGET LINE (nn) IS WITHIN THE LINES TO MOVEICOPY nn LINES (MOVEDICOPIED) USE GET AND/OR PUT (D) TO MCVE LINES IN UPDATE MODE STRING2 CONTAINS MORE ARBITRARY CHARACTERS THAN STRING1 nn OCCURRENCE(S) CHANGED CN nn lINE(S) nn OCCURRENCE(S) CHANGED ON nn LINE(S); nn LINE (S) TRUNCATED INVALID OPERAND : operand nn OCCURRENCES DMSXCM512E INVALID SUBSET CCMMAND DMSXCM513E UNKNOWN CP/CMS COMMAND DMSXCM514E RETURN CODE 'nn' FRCK 'command' DMSXCP037E DMSXCP043E DMSXCP104S DMSXCP105S DMSXCP113S DMSXCP161S DMSXCP411S [OUTPUT] DISK 'mode [cuu]' IS READ/ONLY 'TAPn(cu~' IS FILE PROTECTED ERROR Inn' READING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK (modeIDEVICEIDISKIPRINTERIPUNCHIREADERITAPnITAPINITAPOUT) UNEXPECTED ERRCR CODE Inn' ON 'SYSxxx' (INPUTIOUTPUT) ERROR CODE 'nnw ON 'SYSxxx' DMSXCT002E DMSXCT037E DMSXCT104S DMSXCT105S DMSXCT520E DMSXCT521E DMSXCT5231 DMSXCT526E DMSXCT527E DMSXCT529E DMSXCT531E DMSXCT532E DMSXCT533E DMSXCT534E DMSXCT535E DMSXCT536E DMSXCT537E DMSXCT539E DMSXCT540E DMSXCT541E DMSXCT545E DMSXCT554S FILE 'fn ft fm' NCT FCUND DISK 'mode' IS READ ONLY ERROR Inn' READING FILE 'fn ft fm' FROM DISK ERROR Inn' WRITING FILE 'fn ft fm' ON DISK INVALID OPERAND : operand INVALID LINE NUMBER TYPEWRITER MODE OPTION 'option' VALID IN DISPLAY MODE ONLY INVALID COLUMN NUMBER SUBCOMMAND IS ONLY VALID IN (DISPLAYIEDITING) MODE DISK IS FULL. SET NEW FILEMCDE OR CLEAR SOME DISK SPACE DISK IS FULL; AUTOSAVE FAILED LINE 'linenum' IS NOT RESERVED TOO MANY LOGICAL SCREENS DEFINED INVALID PARMS FCR RENUM NUMBER OF LINES EXCEEDS PHYSICAL SCREEN SIZE EACH LOGICAL SCREEN MUST CONTAIN AT LEAST 5 LINES NAMED LINE NOT FOUND NAME ALREADY DEFINED CN LINE Inn' INVALID NAME MISSING OPERANDeS) NO STORAGE AVAILABLE (cuu) NOT ATTACHED DMSXDC512E INVALID SUBSET CCMMAND Appendix B. Message summary Alphamerically by Message Identifier 317 D8S D8S1DC5201 D8S1DC542E D851DC5431 DKSIDC544E DKSIDC5451 D8S1DCS46E D8S1DC547E D8S1DC548E D8S1DC549E D8S1DC550E DKSIDC554S INVALID OPERAND : operan4 NO SUCH SUBC088AND: name INVALID NUMBER: XXXXJXXX INVALID Hll DA!A : xxxxxxxx KISSING OPERAND(S) TARGET NOT FOUND SYNO~Y8 DEFINITION IICCKPIETE INVALID SYNONYM OPERlND : oFerand SYNONYK ABBREVIATICN TOO lARGE TOO 8ANY OPERANDS IN SYNONYM DEFINITION NO STORAGE AVAILABLE 8ISSING FILEDEF FOR tDNARE SYSIN DKSXDS590E DATA SET TOO lARGE D8S1DS591E OPEN ERROR ON SYSIN DKSIDS5~9E DMSIED553I EDITING FILE: fn ft fm DKSIED554S NO STORAGB AVAILABLE DKSXED55SE FILE 'fn ft fm' AIREltY IN S!CBAGB D8S1EB556S UNDEFINED KESSAGE (tKSXER CAllED AT hex lac) DMSXFC557S DKSIFD554S DKSXFD559W D8S1lD560W NO KORE STORAGE TO IISERT lINES NO STORAGE AVAILABLE WARNING FILE IS EMPTY NOT ENOUGH SPACE FOR SERIALIZATION BETWEEN TRUBC AND LEECL DKSIGT002E DKSIGT104S DKSXGT156E DKSXGT521E DKSIGT562E D8S1GT563W DKSXGT564W DKSIGT565W FILE 'fn ft fm' BCT FeOND ERROR 'nn' READING FILE 'fn ft fm' FaOK DISK 'RECORD nn' NeT FCONt - FILE 'fn ft fm' HAS ONLY INVALID LINE NOMEER, NO LINE(~ SAVED BY POT (D) SOBCCK!AND RECORDS TRUNCATED EOF REACHED EOF RIACHED; RECORDS TRONCATEt DKSIIN002E DMSIIN003E DMSIIN024E DMSIIN029E DMSIIN054E DKSIIN065E DMS1IN066E DKSXIN070E D8S1IN104S DKSIIN132S DMSIIN500E DKSIIN554S DKSIIN571I FILE 'fn ft fm' NOT 100ND INVALID OPTION 'oFtion' FILl 'fn ft fm' ALREIDY E1IS!S [-- SPECIFY 'REPLACE'] INVALID PARAMETES 'parameter' IN THE CP!ION 'option' FIELD INCOMPLETE FIIElt SPECIFIED 'option' OPTION SPECIFIED TWICE 'option' AND 'option' ARE CONPIICTIBG OPTION,S INVALID {PARAMETER 'parameter'IARGU8ENT 'argument'} ERROR Inn' REAtING PILE 'fn ft fm' lRO! DISK FILE 'fn ft fm' TCC lARGE UNABLE TO UNPACK FILE 'fn ft fm' NO STORAGE AVAIIAEIE CREATING NEW FILl '~n' RECORDS DMSII0572E TERMINAL ERROR. FCRCEt CASE OPPERCASE DMS1MA104S ERROR Inn' READING FltE 'fn £t fmt FRCM DISK DKSIMC009E DM5XMC5451 DKSXKC575E DKSIKC576E COLUMN 'col' E1CEEDS RECORt lENGTH MISSING OPERAND(S) INVALID (JOINISPIITITAESIVERIFYIZONE) CCLOKNS DEFINID {TOTAL VERIFY WltTH EXCEEDS SCREEN SIZE (nn) ITOTAL OFfSET EXCEEDS LRECL (nn)} DKSXKD503E DKSXKD5101 DKSIKD529E DMSIKD573I DKSIMD587I TRUNCATED AOTOSAVID AS 'fn ft fa' SUBCOKMAND IS ONLY VltlD IN (DISPLAYIEDITING) MODI INPUT KODE: XEDIT: DMSX815291 SUBCOM8AND IS ONLY VALID IN (DISPLAYIEDITING) !OPE DftS18S0091 DKSXMS0531 DMS18S063E DM518S554S D!SlftS596S 318 COLUftN 'col' E1CEEDS RECORD LENGTH INVALID SORT FIELD P1IR DElINID NO SORT LIST GIVEN NO STORAGE AVAILABLE THIS !ODOLE 8UST EE CAILEt WITHIN TaE EDITOR IB8 VM/SP System !essages and Codes DBS DMSXP0596S THIS MODULE MUST BE CALLE[ DMSXPT037E DMSXFT105S DMSXPT554S DMSXPT5711 DMSXPT579R DMSXPT580W WI~HIN THE EDITOB DISK 'mode' IS READ ONLY ERROR Inn' WRITING FILE 'fn ft fm' ON DISK NO STORAGE AVAILABLE CREATING NEW FILE RECORDS WILL BE TRUNCATED TO nne CONTINUE (YES/NO)?: PUT NOT EXECUTED. DMSXSC117S ERROR WRITING TO DISFIAY TERMINAL DMSXSC5101 AUTOSAVED AS 'fn ft fm' DMSXSE009E DMSXSE037E DMSXSE048E DMSXSE515E DMSXSE519E DMSXSE520E DMSXSE521E DMSXSE524W DMSXSE525E DMSXSE526E DMSXSE528E DMSXSE5301 DMSXSE538E DMSXSE545E DMSXSE548E DMSXSE552E DMSXSE554S DMSXSE558W DMSXSE560W DMSXSE575E COLUMN 'col' EXCEEDS RECOED LENGTH DISK 'mode' IS READ ONLY INVALID MODE 'mode' RECFH MUST BE {FIVIFPIVP} IRECL MUST BE LOWER THAN WltTH (nn) INVALID OPERAND : o~e~and INVALID LINE NUMBER NONDISP CHARACTER RESE~ TO BLANK INVALID PFKEY NUMBER OPTION 'option' VALID IN DISPLAY MODE ONLY INVALID RANGE : TARGET2 (lINE nn) PRECEDES TARGET1 (LINE nn) nn FILE(S) IN S~ORAGE NO NAME DEFINED MISSING OPERAND(S) INVALID SYNONYM OPERANt : operand NO SYNONYM CURRENTLY DEFINED NO STORAGE AVAILABLE WRONG FILE FORMAT FOR SERIALIZA~ION NOT ENOUGH SPACE FOR SERIALIZATION BETWEEN TRUNC AND LRECL INVALID (JOINISPLI~I~AESIVERIFYIZONE) COLUMNS DEFINED DMSXSS561E CURSOR IS NOT eN A VALID tATA FIELD DMSXSU048E DMSXSU062E DMSXSU069E DMSXSU137S DMSXSU229E DMSXSU5101 DMSXSU559W DMSXSU582S DMSXSU5831 DMSXSU5841 DMSXSU585E DMSXSU586E DMSXSU5871 DMSXSU588E INVALID MODE 'mode' INVALID CHARACTER IN FILEID 'fn ft fm' DISK {'mode'l'cuu'I'volid'} NO~ ACCESSED ERROR 'nn' ON STATE FOE 'fn ft fm' UNSUPPORTED OS DA~A SET, [ERROR 'code'] AUTOSAVED AS 'fn ft fm' WARNING FILE IS EMP!Y EDITOR ABEND EOF: TOF: NO LINE(S) CHANGED NOT FOUND XEDIT: PREFIX SUBCOMMAND WAITING ••• DMSXUP002E DMSXUP007E DMSXUP174W DMSXUP1781 DMSXUP179E DMSXUP180W DMSXUP183E DMSXUP184W DMSXUP185W DMSXUF186W DMSXUP207W DMSXUP210W DMSXUF597E DMSXUP598S DMSXUF599S FILE 'fn ft fm' NOT FOUND FILE 'fn ft fm' [IS] NCT PIXED, 80 CHAR. RECORDS SEQUENCE ERROR INTRODUCED IN OUTPUT FILE: ' •••••••• ' TO ' •••••••• UPDATING ['tn ft fm'] WITH 'tn ft fm' KISSING OR DUPLICATE 'MACS' CARt IN CONTROL FILE 'fn ft fa' KISSING PTF FILE 'fn ft fm' INVALID {CONTROLIAUX} FILE CONTECL CABD '.1 S' NOT FIRST CARD IN UPDA!E FILE -- IGNORED {INVALIDINON NUMERIC} CHlRACTER IN SEeUBNeE PIELD , ••••••• ~. SEQUENCE NUMBER [' ••••••••• ] NOT FOUND INVALID UPDATE FILE CO~TROL CARD INPUT FILE SEQUENCE E~~OR ' •••••••• ' TO ' •••••••• ' UNABLE TO MERGE UPDA~ES CONtAINING '.1 5' CARDS UNABLE TO BUILt UPDATE FILE INTERNAL LIST DESTROYED UNABLE TO BUILD UPDATE FILE : SERIALIZATION DESTROYED DMSZAP001E DMSZAP002E DHSZAP002W DMSZAP003E DMSZAP007E DMSZAP014E DMSZAP047E NO FILENAME SPECIFIED [INPUTIOVERLAY] (FILE[ (S) ]IDATA SET) [Ifn [ft (fm]]'] NOT FOUND FILE 'fn ft [fm]' NCT FOUND INVALID OPTION 'option' FILE 'fn ft fm' [IS] NOT FIXED, 80 CHAR. RECORDS INVALID KEYWORD 'fuDction' NO FUNCTION SPECIFIID Appendix B. ~essage Summary Alpbamerically by Message I~entifier 319 DMS DMSZAP056E DMSZAP070E DMSZAP104S DMSZAP190W DMSZAP191W DMSZAP192W DMSZAP193W DMSZAP1g4W DMSZAP195W DMSZAP200W DMSZAP208E DMSZAP210E DMSZAP245S DMSZAP246W DMSZAP247W DMSZAP248W DMSZAP2491 DMSZAP7501 DMSZAP7511 320 PILE 'fn ft [fm]' CONTAINS INVALID (NIMEIALIASIENTBIIESD) BECOBD PORMITS INVALID {PARAMETER 'p_rameter'11RGUBENT 'argument'} ERROR 'nn' READING PILE 'fn ft fa' PROM DISK INVALID CONTROL RECORt OR NO GO SWITCH SET PATCH OVERLApS - SET NC GO SWITCH ERROR - ODD NUMBER OP DIGITS - SET NO GO SWITCH PRECEDING CQNTEOL RECaED ItOSBED ~SECT NOT FOUND IN {BEMBER 'mEmber~ame'IMODULE 'modulenaae'} -SET NO GO SWITCH BASE VALUE INVALID - SET NO GC SWITCH VERIFY REJECT ~ SET NC GO SWI~CH FILE 'fn ft' IS NOT VlBIAELE BECORD FORMAT {LIBBARYIFIL!} 'tn ft' IS ON 1 READ/ON~Y DISK ERROR 'nnn' ON PBINTER NO LOADER TABLE PRESENT FCR MCDULE 'fn' - SET NO GO SWITCH MEMBER 'name' NOT leUND - SET NO GO ~WITCH INVALID VER/REP DISP - SET NO GC SWITCH DUMMY LOG ENTRY IN PIL! 'fn ZAPLOG fa' ZAP PROCESSING COMPLETE MEMBER 'name' FOOND IN LIBRARl 'libname' IBM VM/SP System Messages and Codes DMT RSCS Message Summary DKTAXS1011 DKTAXS1021 DKTAXS103E DMTAXS1041 DMTAXS1051 DKTAXS1061 DKTAXS1071 DKTAXS108E DMTAXS5201 DMTAXS5211 DMTAXS5221 DMTAXS5231 DMTAXS524E DMTAXS525E DMTAXS526E DMTAXS6401 FILE spoolid ENQUEUED CN lINK linkid FILE spoolid PENDING FOR lINK linkid FILE spoolid REJECTED -- INVALID DESTINATION ADDRESS FILE SPOOLED TO userid2 -- ORG locidl (name1) mm/dd/yy hh:mm:ss FILE spoolid PURGED FILE spoolid MISSING -- DEQUEUED FRO! LINK linkid nn PENDING FILES POR lINK linkid MISSING SYSTEM ERROR REAtING SFOOL PILE spoolid FILE spoolid CHANGEt PILE spoolid HELD FOR lINK linkid FILE spoolid RELEASED FOR lINK linkid LINK linkid QUEUE REORtERED FILE spoolid ACTIVE -- NO ACTION TAKEN FILE spoolid IS POR LINK linkid -- NO ACTION TAKEN FILE spoolid NCT FOUND -- NO ACTION TAKEN nn FILE(S) PURGED ON lINK lin kid DKTCMX0011 DMTCKX0031 DMTCMX2001 DMTCKX201E DKTCMX202E DMTCMX203E DKTCMX204E DMTCKX205E DMTCMX206E DMTCMX207E DKTCKX208E DMTCMX3001 DMTCMX301E DMTCKX302E DMTCKX303E DMTCMX304E DKTCMX5401 DMTCMX5411 DKTCMX542E DMTCMX543E DMTCMX544E DMTCMX5501 DMTCMX551E DMTCMX552E DMTCMX5601 DMTCMX561E DMTCMX6511 DMTCMX6521 DMTCMX6531 DMTCMX6541 DMTCMX6551 DMTCMX6601 DMTCMX6611 DMTCMX6621 DMTCMX6631 DMTCMX664E DMTCMX6701 DMTCMX6711 DMTCMX6721 DMTCMX6731 DMTCMX7001 DMTCMX701E DMTCKX702E DMTCMX703E DMTCMX704E DMTCMX705E DMTCMX706E DMTCMX707E DMTCMX708E DMTCMX709E DMTCMX710E DMTCMX750E DMTCMX7511 FREE STORAGE = nn PAGES LINK lin kid EXECUTING: (command line text) RSCS INVALID COMMAND command INVALID LINK linkid INVALID SPOOL FILE ID spoolid INVALID KEYWORD keyword CONFLICTING KEYWORD keyword INVALID OPTION keyword option CONFLICTING OP~ION keyword option INVALID USER ID userid ACCEPTED BY TASK task REJECTED BY TASK task -- FREVIOUS COMBAND ACTIVE LINK lin kid IS NOT DEFINED LINK linkid IS NOT ACTIVE REJECTED BY TASK task -- NOT RECEIVING NEW LINK linkid DEFINEt LINK linkid REtEFINED LINK linkid ACTIVE -- NOT REDEPINED LINK linkid NOT DEFINEt -- LINK lIMIT REACHED LINK linkid NOT DEFINEt -- TYPE NeT SPECIFIED LINK linkid NOW DELETED LINK linkid ACTIVE -- NOT DELETED LINK lin kid HAS A PILE QUEUE -- NOT DELETED RSCS DISCONNECTING USERID userid NOT RECEIVI8G LINK lin kid INACTIVE LINK linkid ACTIVE task type vaddr c {HOI NOH) {DRINOD} {TRAITREINOT} Q=m P=n LINK linkid DEFAULT task type vaddr c F=m LINK lin kid Q=m P=n FILE spoolid locid userid CL a PR mm REC nnnnnn {All} FILE spoolid INACTIVE CN lINK linkid FILE spoolid ACTIVE ON LINK linkid FILE spoolid ORG locidl useridl mm/dd/yy hh:mm:ss TO loclid2 userid2 FILE spoolid PR mm CL a CO nn {HOI NOH} DI distcode, NA {fn ftldsnam~ FILE spoolid NOT FOUND LINK linkid ACTIVE -- lINE vaddr {HOI NOH) LINK lin kid INACTIVE NO LINK ACTIVE NO LINK DEFINED ACTIVATING LINK linkid task type vaddr c NO SWITCHED LINE AVAILABLE -- lINK linkid NOT ACTIVATED LINE vaddr IS IN USE EY lINK linkidl -- LINK linkid2 NOT ACTIVATED DEV cuu IS NOT A lINE PORT -- lINK linkid NOT ACTIVATED LINE vaddr CC=3 NOT CFERATICNAI -- LINK linkid NOT ACTIVATED DRIVER type NOT FOUND ON DISK vaddr -- LINK linkid NOT ACTIVATED FATAL ERROR LOADING FRCM vaddr -- LINK linkid NOT ACTIVATED DRIVER type FILE FCRMAT INVALID -- LINK linkid NOT ACTIVATED VIRTUAL STORAGE CAPACITY EXCEEDED -- LINK linkid NOT ACTIVATED TASK NAME task AlREADY IN USE -- LINK linkid NOT ACTIVA~ED MAX (nn) ACTIVE -- LINK linkid NOT ACilVATED LINK linkid ALREADY ACTIVE NO ACTION TAKEN LINK lin kid ALREADY ACTIVE NEW CLASS (ES) SET AS REQUESTED Appendix B. Message Summary Alphamerically by Message Identifier 321 DMT DMTC!X7521 LINK linkid STILL ACTIVE ~- DRAIN STATUS RESET DMTINI402T D!TINI407R D!TINI409R DMTINI410R D!TINI431S DMTINI479E DMTINI480E DMTINI481E DMTINI482E D!TINI483E IPL DEVICE READ I/O EREOR REWRITE THE NUCLEUS? [YESINO] NUCLEUS CYL AVDRESS = nnn ALSO IPL CYLINDER O? (YESINO] IPL DEVICE WRITE I/C ERROR INVALID DEVICE ADDRESS - REENTER INVALID CYLINDER NUMEEE - REENTER INVALID REPLY - ANSWER "YES" OR "NO" SYSTEM DISK ERROE - REENTEE NUCLEUS WILL OVERLAY CMS FILES - RECOMPUTE DMTNPT070E DMTNPT904E DMTNPT907E DMTNPT936E DMTNPT108E DMTNPT1411 DMTNPT1421 DMTNPT1431 DMTNPT1441 DMTNPT1451 DMTNPT1461 DMTNPT1471 DMTNPT1491 D!TNPT1601 DMTNPT1701 DMTNPT190E DMTNPT5101 D!TNPT511E DMTNPT530I DMTNPT5701 DMTNPTS71E DMTNPT580I DMTNPT581E DMTNPT5901 DMTNPT591E DMTNPT6QOI DMTNPT6101 DMTNPT611I DMTNPT612E DMTNPT8011 DMTNPT8021 DMTNPT8031 DMTNPT810E DMTNPT811E DKTNPT902E D"TNPT903E DMTNPT905I DKTNPT934E I/O ERROR cuu SIOCC cc CSW csw SENSE sense CCW ccw SIGNON PARAMETER=parameter INVALID SIGNON TYPE PARAMETER MISSING NO REMOTE PUNCH AVAILAELE O~ LINK linkid -- FILE spoolid PURGED SYSTEM ERROR READING SIOOl FILE spoolid LINE vaddr READY FOR CONNECTION TO LINK linkid LINK linkid LI~E vaddr CONNECTED LINK lin kid LINE vaddr DISCONNECTED RECEIVING: FILE FROM locid1 (name1) FOR locid2 (userid2) RECEIVED: FILE FROM locid1 (name1) FOB locid2 (userid~ SENDING: FILE spoolid CN LINK linkid, BEC nnnnnn SENT: FILE spoolid ON LIN~ linkid LINK linkid LINE ACTIVITY: TOT= mmm; ERRS= nnn; TMOUTS= ppp LINE vaddr DISABLED FCE LINK 1inkid FROM linkid: (MSG message text) INVALID SPOOL BLOCK FeEMAT CN lILE spoo1id FILE spoolid BACKSPACED NO FILE ACTIVE ON LINK 1inkid COMMAND FORWARDED ON lINK linkid LINK linkid NOW SET TO DEACTIVATE LINK linkid ALREADY SET TC DEACTIVATE FILE spoolid PROCESSING TERMINATED FILE spoolid NOT ACTIVE LINK linkid RESU!ING FILE TRANSFER LINK linkid NOT IN HOLD STATUS FILE spoolid FORWARD SPACED LINK linkid TO SUSPEND FILE ~RANS!ISSION LINK linkid FILE TRANSMISSICN SUSPENDED LINK lin kid ALREADY IN HOLD STATUS LINK linkid ERROR TEACE STARTED LINK linkid TRACE STARTED LINK linkid TRACE E~DED LINK linkid TRACE ALREADY AC!IVE LINK linkid TRACE NCT ACTIVE NON-SIGNON CARt READ ON LINK linkid PASSWORD SUPPLIED O~ LINK 1inkia IS INVALID SIGNON OF LINKID (linkid) CO~~tETE ID CARD KISSING ON lIE~ linkid -- INPUT FILE pURGED DMTREXOOOI RSCS (VER v, LEV 1, mm/dd/yy) READY DMTREX0021 LINK linkid DEACTIVA!ED DMTREX091T INITIALIZATION FAILURE -- ascs SHUTDOWN DMTS!t070E DMTS!L108E DKTS!L1411 DMTSML1421 DKTSKL1431 DMTSKL1441 DMTSML1451 DKTSKL146I DMTSKL147I PMTSML1491 DMTSML1601 DMTSKL 1701 DMTSML190E D!TSKL5101 DMTSKL511E DMTS!L5701 DMTSKL571E 322 I/O ERROR cuu SIOCC cc CS'il csw SENSE sense CCW ccw SYSTEK ERBOR READING SEOOl lILE spoolid LINE vaddr READY lOR CONNECTION TO LINK linkid LINK lin kid LINE vaddr CONNECTED LINK linkid LINE vaddr DISCONNECTED RECEIVING: FILE FROK locid1 (name1) lOR locid2 (userid2) RECEIVED: FILE FROK locid1 (name1) FOR locid2 (userid2) SENDING: FILE spoolid ONLIRK link~d~ REC nnnnnn SENT: FILE spoolid ON LINK linkid LINK linkid LINE ACTIVITY: TOT= mmm; ERRS~ onn; T!OUTS= ppp LINE vaddr DISABLED lCE LINK linkid FROM linkid: (KSG message text) INVALID SPOOL BLOCK FOE!lT ON PILE spoolid FILE spoolid BACKSPACED NO FILE ACTIVE ON LINK linkid LINK linkid NO'il SET TO DEACTIVATE LINK linkid ALREADY SET TO DEACTIVATE IBK VM/SP System Messages and Codes DII! DMTSML580I DMTSML581E DMTSML590I DMTSML591E DMTSML600I DMTSML610I DMTSML611I DMTSML612E DMTSML801I DMTSML802I DMTSML803I DMTSML810E DMTSML811E DMTSML901E DMTSML902E DMTSML903E DMTSML9051 DMTSML906E DMTSML934E DMTSML935E DMTSML936E DMTSML937E FILE spoolid PROCESSING TERIINATED FILE spoolid NO~ AC~IVE LINK linkid RESUMING FILE TRANSFER LINK linkid NOT IN HOLD STA~US FILE spoolid FORiARI SPACED LINK lin kid TO SUSPEND FILE TRANSMISSION LINK linkid FILE TRANSMISSICN SUSPENDED LINK lin kid ALREADY IN BOLD S~ATUS LINK linkid ERROR TRACE STARTED LINK linkid TRACE S1ARiED LINK lin kid TRACE ENDED LINK linkid TRACE ALREADY ACTIVE LINK linkid TRACE NC~ ACTIVE INVALID SML MODE SPECIFIED -- LINK (linkid) NOT ACTIVATED NON-SIGNON CARD REAt eN LINK linkid PASSWORD SUPPLIED ON LINK linkid IS INVALID SIGNON OF LINKID linkid CCMPLETE INVALID SML BUFPER PARAME~ER -- LINK (linkid) NOT ACTIVATED ID CARD MISSING ON lINK linkid -- INPUT FILE PORGED LINK (linkid) IN RJE MODE -- PRINT FILE (spoolid) PORGED NO REMOTE PUNCH AVAILABLE ON lINK linkid -- PILE spooled PURGED DECOMPRESSION ERROR eN linkid -- LINK DEACTIVATED Appendix B. Message summary Alphamerically by !essage Identifier 32~ DMM I pes Message Summary DMMCPAB05I 'nnn' ABEND CODE NOT RECOGNIZED EY DATA EXTRACTION DMMDSC500S DMMDSC700I DMMDSC701R DMMDSC7191 DMMDSC7201 DMMDSC7211 DMMDSC7221 DMMDSC7231 ERROR 'nnn' WRITING TO VIRTUAL PRINTER TYPE 'HELP' OR ENTEE ENTER DUMP NUMBER AND MODE ERROR 'nnn' IN FSSTATE 'filename filetype fm' LOAD MAP ALREAtY PRESENT SNAME TABLE IS FUll INVALID ENTRY INTO SNAME TABLE THE DUMP IS NCT ON THE A-tISR DMMEDM850I DMMEDM8511 DMMEDM8521 DMMEDM853I DMMEDM8601 DMMEDM8611 DMMEDM863E DMMEDMB641 UNABLE TO READ DUMP FEOM READER TEN DUMP FILES AIREAtY EXIST FATAL I/O ERROR WRITING DUMP NO DUMP FILE EXIST FATAL I/O ERROR REAtING DUMP DUMP FILE 'filename' NeT FCUND INVALID PARAMETER - parameter PAGE REFERENCED NOT AVAILAEIE WHILE EDITING xxxxxxxx DMMFED7021 NON-HEX CHARACTER IN COUNT - RETRY DMMFED7031 NON-HEX CHARACTER IN ADDRESS - RETRY DMMFEX7041 NON-HEX CHARACTER IN ADDRESS - RETRY DMMGET100S ERROR 'nnn' READING FILE 'filename filetype fm' DMMGET70BI PAGE 'page' NOT FOUND IN DUMP DMMGRC100S ERROR 'nnn' READING FILE 'filename filetype fm' DMMGRC8091 REQUESTED ADDRESS NOT IN DUMP DMMHEX7141 NON-HEX CHARACTER IN INPUT - EETRY DMMINI100S DMMINI200S DMMINI300S DMMINI400S DMMINI800S DMMINIB03S ERROR 'nnn' READING FILE 'filename filetype fm' ERROR 'nnn' WRITING FILE 'filename filetype fm' ERROR 'nnn' ON FSSTATE 'filename filetype fm' ERROR 'nnn' CICSING 'filename filetype fm' DATA EXTRACTION FAILURE ERROR 'nnn' ATTEMPTING TO ICAD!Ct VMFDUMP2 DMMIOE7121 DEVICE 'cuu' NOT FOUND DMMIOB7131 USER 'userid' VMBIOR NCT FCUNt DMMLOC715I NON-HEX CHARACTER IN STRING DMMLOC716I STRING 'string'}NCT FCUNDINCT FCUND BEFORE END OF DUMP{ DMMLOC7171 INVALID FORM OF LOCATE COMMAND DMMMAP200S ERROR 'nnn' WRITING FILE 'filename filetype fm' DMMMAP8011 DMMMAP802I DMMMAPB06R DMMMAPB071 DMMMAPBOBI DMMMAPB101 NUC MAP 'filename filetype fm' IS NOT VALID FOR THIS DUMP. PROCEEDING •••• ENTER 'filename filetype fm' OF NUCLEUS LOAD MAP OR ENTER NULL UNABLE TO LOCATE 'filename file type fm' NUCLEUS MAP INVALID 'filename filetype fm' ERROR 'nnn' READING FILE 'fileid' DMMMCD100S DMMMOD705E DMMMOD7061 DMMMOD707I DMMMOD71BI ERROR 'nnn' READING FILE 'filename filetype fm' ERROR IN ITEM TAELE 'entry name' NOT FOUND IN THE lCAD MAP 'module' 'page' PAGE NOT VALID THIS DUMP HAS NO 10At MAP - SEE MAP SUBCOMMAND DMMPRM200S ERROR 'nnn' WRITING FILE 'filename filetype fm' DMMPRM804I PROCESSING ERROR IN DATA EXTRACTION DMMPR0100S ERROR 'nnn' READING FILE 'filename filetype fm' DMMPR0200S ERROR 'nnn' WRITING FILE 'filename filetype fm' DMMPR0300S ERROR 'nnn' ON FSSTAT! 'filename filE type fm' DMMREG100S ERROR 'nnn' READING FILE 'filename filetype fm' 324 IBM VM/SP System Messages and Codes DMM DMMREG72~I DMMREG72~I {AP} REGISTERS REQUESTED FOR UNIPROCESSOR DUMP {MP} REGISTERS REQUESTED FOR UNIPROCESSOR DUMP DMMSCR709I NO VALID SCROLL ADDRESS DMMSEA100S ERROR 'nnn' READING FILE 'filename filetype fm' DMMSTA100S ERROR 'nnn' READING FILE 'filename filetype fm' DMMSTA200S ERROR 'nnn' WRITING FILE 'filename filetype fm' DMMSTA601I OPERAND 'operand' NOT RECOGNIZED DMMSUM100S DMMSUM200S DMMSUM501S DMMSUM502S ERROR 'nnn' READING FILE 'filename filetype fm' ERROR 'nnn' WRITING FILE 'filename filetype fm' INVALID PARM 'badparm' PASSED TO SUMMARY UPDATE PROGRAM PROBLEM 'PRBnnnnn' NOT FOUND IN SYMPTOM SUMMARY DMMTRC710I NON-NUMERIC COUNT CHARACTER - RETRY DMMVMB711I LOOP IN VMBLOK CHAIN DMMWRT200S ERROR 'nnn' WRITING FILE 'filename filetype fm' Appendix B. Message summary Alphamerically by Message Identifier' 325 326 IBB VB/SP System Bessages and Codes DMK Appendix C: Message-to-Module Cross-Reference This appendix contains all the VM/SP message identifiers, listed in numerical order vertically. Use this appendix when you want to find out which modules issue a given message. Find the message number within its component code group (CP, eMS, RSCS, or IPCS); all the message identifiers with the same number appear together. RSCS and IPCS messages 6 level. !Q~: remain at the VM/370 Release CP Message Summary DMKCFCOO1E DMKCFCOO2E DMKCFGOO2E DMKCFT002E DMKCFW002E DMKMCCOO2E DMKMCDOO2E DPlKMNI002E DPlKNEAOO2E DMKNESOO2E DMKNET002E DMKNLD002l: DPlKSPTOO2E DMKTBIOO2E DMKTRA002E DMKTRPOO2E DMKTRROO2E DMKCQSOO2E DMKCDB003E DMKCDMOO3E DMKCFGOO3E DMKCFOOO3E DMKCFSOO3E DMKCPTOO3E DPlKCPVOO3E DPlKCQPOO3E DMKCQROO3E DMKCSBOO3E DMKCSOOO3E DMKCSP003E DMKCSTOO3E DMKCSUOO3E DMKDEFOO3E DMKLOG003E OMKMCCOO3E DPlKMCIOO3E DMKMSGOO3E DHKNET003E DMKNLEOO3E DMKSPT003E DMKTHI003E DMKTRA003E DMKUSOO03E D!KVDE003E DMKCDBOO4E DPlKCDMOO4E DHKCDS004E DMKCFCOO4E DMKCFD004E DMKCPVOO4E DMKNESOO4E DMKNETOO4E DMKCDSOO5E lHU{ CP BOO 5 E DMKTRP005E DMKTRROO5E DMKCFOOO6E DMKCFSOO6E DMKCFTOO6E DMKCPB006E DMKCPVOO6E DMKCQPOO6E DMKCSB006E DMKCSOOO6E DMKCSP006E DliKCSTOO6E DMKCSU006E DMKDIBOO6E DKKMCCOO6E DMKNEA006E DMKNESOO6E DMKNETOO6E DMKNLDOO6E DMKNLEOO6E DMKSPTOO6E DMKVDDOO6E DMKVOEOO6E DMKCPV007E DPlKCSPOO7E DPlKCSUOO7E DMKCSUOO8E DMKTRROO8E DMKSPTOO8E DMKCDBOO9E DMKCDM009E DMKCPVOO9E DMKDEIOO9l!: Dl!KNESOO9E DMKNETOO9E DMKVMD009E DMKCDB010E DMKCDS010E DMKDIA011E DMKDla011E DMKCDS012E DMKCPB012E DMKCFG013E DMKCFOO13E DMKCQH013E DMKCSB013E DMKCSOO13E DMKCSP013E DPlKCSU013E DMKCSV013E DMKTRA013E DPlKTRP013E DMKVMD013E DMKSPS014E DMKDIA017E DMKCFOO20E DMKCPV020E Dl'lKCQG020E DMKCQP020E DMKCQR020E DMKCQY020E DMKCSP020E DPlKCSU020E DMKDIA020E DMKDIB020E DPlKLNK020E DPlKLOG020E DPlKPlSG020E DMKNEA020E DPlKQVM020E DMKSND020E DMKTRP030E DMKUSOO20E DPlKVDD020E DMKVDE020E DMKVMD020E DPlKCFD021E DMKCFOO21E DMKCPT021E DMKCPU021E DMKCPV021E DPlKCQP021E DMKCSB021E DMKCSOO21E DMKDEI021E DHKMCC021E DMKMCD021E DMKNES021E DMKNET021E DMKNLD021E DMKNLE021E DMKSPT021E DMKVDD021E DMKVDE021E DMKCFD022E DMKCFG022E DMKCPB022E DMKCQG022E DMKCQP022E DMKCSBO 22E DMKCSP022E DKKCST022E DMKDEF022E DMKDIA022E DMKDIB022E DMKLNK022E DMKVDD022E DKKVDE022E DMKVMI022E DI1KVDE023E DMKCQH024E DMKCSOO24E DPlKCSP024E DMKCSQ024E DI1KCSU024E DIUCSV024E DMKDEF024E DIUS:l>T024E DMKDEF025E DPlKDEH025E DMKCDB026E DMKCDS026E DPlKCFC026E DMKCFD026E DKKCFG026E DMKCFH026E DMKCF0026E DMKCFS026E DMKCFT026E DPlKCFW026E DMKCPB026E DMKCPT026E DMKCPV026E DMKCQR026E Appendix C. P1essage-to-Plodule Cross- Ref erence 327 DMK DMKVCB048E DMKCFG083E DMKCPOO49E DMKCPT049E DMKCPT049E DMKNES049E DMKNET049E DMKCPOO49E DMKCFS086E DMKLOG050E DMKDEB092E DMKLOG092E DMKCFS052E DKKLNK052E DMKLOG052E DlfKLOG093E DMKCQY026E DMKCSB026E DMKCSP026E DMKCST026E DMKCSU026E DMKDEF026E DMKDEB026E DMKDEI026E DMKMCC026E DlfKMCD026E DMKMCI026E DKKNEA026E DKKNES026E DMKNET026E DMKNLD026E DMKSPM026E DMKSPS026E DMKSPS026E DMKTBI026E DMKTRA026E DMKTRP026E DMKTRR026E DMKCPT040E DMKCPV040E DMKCQG040E DMKCQP040E DMKCSB040E DMKCSOO40E DMKCSP040E DMKCST040E DMKDEF040E DMKDIB040E DMKKCC040E DMKMCD040E DMKNEA040E DMKNES040E DMKNET040E DMKNLD040E DMKNLE040E DMKSPT040E DMKVDD040E DMKVDE040E DMKLOG054E DMKDIA098E DMKNES098E DMKNET098E DKKCQG027E DMKCST027E DMKCSU027E DKKTRR027E DKKCQG042E DMKCST042E DMKCSU042E DMKTRR042E DMKDIA055E DMKLNK101W DMKDIA056E DMI(LNK102W DMKCQG028E DMKCQR028E DMKCSB028E DMKCSOO28E DMKCSP028E DKKCSU028E DMKSPS028E DMKCSB043E DMKMSG057W DMKLNK103W DMKCFG044E DMKCFB044E DMKCFS044E DMKNLD044E DMKSNC044E DMKDIB058E Dl!KLNK104E DMKALG059E DMKLNK105E DMKCDM060E DMKLNK106E DlfKCDM061E DMKLNK101E DKKCFV062E DMKLNK108E DKKCFV063E DMKLNK109E DMKVAT064E DMKLNK110E DKKLOG067E DKKLNK111E DKKSND068E DKKLNK112E DKKSSS010E DMKLNK113E DMKSSS071E DlfKLNK114E DKKSSS012E DMKALG115E DlfKLNK115E DMKCSP029E DMKCSU029E DKKCSOO30E DMKCSP030E DKKCSU030E DMKCSB031E DMKCSP032E DMKCSU032E DMKCDM033E DKKCDS033E DMKCPV033E DMKNET033E DMKVMD033E DMKVCH034E DKKVDE034E DMKCSU035E DMKCSB036E DMKSPS037E DMKDDR038E DMKVMD038E DMKVDA039E DMKVDE039E DKKCFD040E DMKCFG040E Dl'tKCFOO40E D!lKCPB040E 328 DMKCFS053E DMKCSP053E DMKCSU053E DMKLNK053E DMKLOG053E DMKVMD053E DMKCFOO41E DMKCFOO45E DMKCFS045E DKKCPV045E DKKCQG045E DKKCQP045E DMKCQR045E DKKCQY045E DKKDIA045E DKKDIB045E DKKMSG045E DKKSND045E DKKTBI045E DMKTRP045E DMKUSOO45E DMKVDD045E DMKVDE045E DMKCFOO46E DMKCFP046E DMKCFS046E DMKCPT046E DKKCPV046E DlfKCSB046E DMKCSOO46E DKKDEI046E DMKMCC046E D!lKNEA046E DMKNES046E DKKNET046E DMKNLD046E DMKNLE046E DMKSPT046E DKKVDD046E DMKVDE046E DMKDIA041E D!lKDIB041E DMKLOG090E DHKDEF091E DMKLOG091E DMKDEF094E DMKDEB094E DMKDEF095E DMKLOG095E DKKSSS014E DMKLNK116E DKKDEI075E DMKSSS015E DlfKLNK117E DMKVDA016E DlfKLNK118E DMKVDA077E DlfKLNK119E DMKSSS0181 DlfKNEA120E DMKVDE120E DMKCFV080E DKKLOG080E DKKLOG081W DMKNEA121E DMKVDD121E DMKVDE121E DMKCFV082E DMKLOG082E DMKNEA122E D!lKVDE122E IBM V!l/SP System !lessages and Codes D!lK DltKCPT123E DMKVDD123E D!lKVDI123E DMKCP0124E DltKCPT124E DlIKVDD124E DMKVDE124E nMKCP0124E DMKDE1143E DMKMCC143E DMKNLD143E DMKNLE143E DMKSPT143E DMKVDD143E DMKVDE143E DKKCP0143E DMKCPS144W DMKVDE125E DlIIJKVD!126E DMKJRt1451 DMKVMD1461 D!lKVDE127E DMKVCH147E DMK.VDI12SE DMKCSB148E DMKVCH129E D!lKCPH173E D!lKBLD200E DMKCPG174E D!lKBLt>201E DMKCFG175E D!lKCF0175E D!lKCPS175E DlIKBLD202E DMKCPV202E DKKCPV176E D!lKCFG203E DMKCPV203E DKKCPG177E D!!KCPV204E DMKSNC178E DHKCPS20SE D!lKCPG 179E DMKCFH119E DMKCPP 17 9E DKKCPS179E DKKSNC179E DMKD1A206E DMKLOH206E DMKMCC211E DMKACR149E DMKVCB130E DMKCP1131E DMKLOG131E DMKVDE131E DKI<:VCB132E DMKTRA180W D!!KVDA135E DltKVDD135E DMKCPT136E DMKDEP136E DMKLNK137E DMKATS181E DHKCF01QOE DMKCP0140E DMKCPT140E D!lKCPV140E DMKCSB140E DMKCS0140E DMKMCC140E DMKNES140E DKKNET140E DHKNLD140E DHKNLE140E DMKSPT140E DKKVDA140E DHKVDD140E DMKCP0140E DMKCS0141E DMKCP0142E DMKCPT142E DMKCSB142E DMKVDD1Q2E DMKVDE142E DHKCP0142E D!lKCF0143E DHKCP0143E D!lKCPT143E DMKMCC213E DMKTTY152E DMKTRA182E DMKMCD214E DMKDEF153E DMKLNK153E DMKVDE153E DMKCFS183E DMKCPT15QE DMKCP0184E D!lKCFS 184E DHKMCC216E DMKNET157E DMKCPI185E DMKHCC217E DIiKCDB160E DMKCDM160E DMKCDS160E DMKCFD160E DMKCPV160E DMKNES160E DltKNET160E DMKVHD160E D!lKCP0186E DMKMCD218E DMKCFS187E DMKMON2191 DMKCF0188E DMKCPS188E DMKLOG188E DHKVCH18SE DMKMON2201 DMKCDS161E DMKVHA161E DMKCPS1891 DKKLOG1891 DHKMCD223E DMKCDS162E DHKCDS162W DMKCPS1901 DMKHCD224E DMKCPU191E DMKMNI225E DMKCPT192E DMKCPU192E DMKMCD226E DHKVCH138E DHKLNK139E DMKMCD212E DMKQCN150A DMKVDE133E DHKVDD134E DKKVDE13QE DHKHEA208E DMKCDS163E DMKCDS164E DMKCFD164E DHKCFP164E D!lKMCC215E DMKMCC221E DHKHCD222E DMKHCD227E DMKCPU1931 DHKMCD228E DMKCPV1651 DHKCPU1941 DMKCDS166E DMKLOH196E D8K81A229E DMKCPJ2291 DMKC~G170E DMKUS0197E DMKVM1230E DHKCP0198W D!lKVMI231E DHKC!'0199l!l DMKCPV199E DMKD1A199E DMKLNK199E DMKMCC199E DHKNES199E DHKNET199E D!lKHLD199E DHKNLE199E D!lKSPT199E DHKVDE199E DMKVMI232E DMKCFH170E DMKCFS170E DMKNLD170E DMKCFG171E DMKCFfl171E DMKCFS171E DMKNLD171E DltKSNC171E DMKCFG112E DHKCFH172E DHKCFG173E DMKVMI233E D!KVMI234E D!lKRSE240E DHKTCS240E D!lKRSE241E DIKTCS241E Appendix C. Hessage-to-!lodule Cross-Reference 329 DIIK DIIKIS!521! DIIKT1P5211 DIIKT1P5221 DftKCCH6021 DftKDD!712E DIIKD1!760E DftKCCfl603i D!KDD!713E DIIKD1R761E DftKCCH6051 D!KDDR714E DftKD1R762E DIIKftCH609W DftKl>DR715E DftKD1R763E DftKHCH610W DIIKIIC'l'610W D!U ftKDDR729I D!KRND851:t DI!KCKP5361 DftKCP15361 DI!KD1D5361 D!!kD1S536I DIIKD1U5361 DftKDDB536I DHkD1I5361 DftKDI!P5361 D!!K1ft'l'5361 DftKS1V5361 DHKSSP5361 D!KftC'l'621I D!KGBF5311 DHKGRP5321 DlfKD1U533I DftKSPH805E D!KQVft806E D!KQVH807E D!KF!!T730E D!KRND8521 D!K1CU622W DftKftCH622W DftKP!T732E D!KRND853:t DftKCPP6231 DIIKftC'!'6231 DftKPlfT733E D!KBND861E D!KFft'!'734E DHKRND863E DftKP!T735E DHKRND8641 DHKFHT736E DKKCKP900W DHKP!!T737E DHKCKP901W DHKFH'!'7381 D!KCKP902W D!!KFftT739E DKKCKT903W D!KF!T740E DMKWR!904W DftKIlCH6241 DIIKHCT625I DftKD105381 DHKDDR700B D!KDID5461 DHKDDB701E DIIKIOP550E D!!1(DDR702E DftK1OG551E DftKDDR703E DftKIOG5521 DHKDDR704E D!KD1R751E D!KDHP905W Dlf1(IOG5531 DftKDDl705E DlfKRG1705! DftKDIR752E D!KDftP906W D!K.~S706E DIIKDIR753E DHKD!!P907W D!!KD117071 DlfKDDR707B DIIKD1B754E DHKDIIP908:t Dlllt1OH560W DIIKD1R755E DIIKDftP909W DIIKIOH5611f DHKDDR708E DIIKDDR709E DHKDDR756E DlfKDIB756B DlfKF!T756E DHKCKP910W DIIK'ER575I D!!KCP'l'601E DIIKCCH6011 DlfKnDB7101 DlfKDIB757E DlfKCKT912W DIIKCKV912W DIIKWI!912W DlfK1OG5581 DIII10H559W DIIKCPT602E DIIKDDI711R lH!KDIR758B DlfKCKP911W 1ppendix C. Hessage-to-Hodule Cross-Reference 331 DMK DMKCPI913I DMKDMP913I I DMKCPI968I DMKCLK970W DMKCPI914I DMKCKS915E DMKCKV915E DMKCKT916E DMKCKV916E DMKCKV917E DMKDMP918I DMKCKS919E DlIJKWRM920I DMKWRM921W DMKCKP922W DMKCPI923I DMKCPV923I DMKLD0923I DMKCPI924I DMKCPV924I DMKLD0924I DMKCF0925I DMKDRD925I DMKCF09251 DMKCPI950A DMKCPI951I DMKCPI952I DMKCF09531 DMKCPI953I DMKCPI954E DMKCPI955W DMKDAD956A DMKDAS956A DMKDSB956A DMKCPI9571 DMKCPI958I DMKCPI959W DMKCKP960I DMKCKP961W DMKCPI961W DMKCPI962I DMKVDE962I DMKCPI963I DMKCPI964I DMKCPJ966I DMKCPJ967I 332 IBM VM/SP System Messag-'4!sand Codes DMKCPI971I DKS eMS Message Summary DMSAMSOO1E DMSABNOO1E DMSARXOO1E DMSASl-1001E DMSDLBOO1E DKSDLKOO1E Dl-1SERVOO1E DMSEXCOO1E DMSICPOO1E DMSIKAOO1E DMSLBl-1001E DI1SLBTOO1E DI1SLIOOO1E DMSLKDOO1E DMSMDPOO 1E DMSMODOO1E DMSNCPOO 1E DMSNXLOO1E DMSPREOO1E DMSRUNOO1E DMSTMAOO1E DMSUPDOO1E DMSZAPOO1E DKSACCOO2E DKSAMSOO2E DKSARNOO2E DMSARXOO2E DMSASMOO2E DKSCMPOO2E DMSCPYOO2E DMSDSKOO2E DMSDSLOO2E DMSERSOO2E DMSERVOO2E DMSGRNOO2E DMSICPOO2E DMSIFCOO2E DMSIMAOO2E Dl-1SLBMOO2E DMSLBTOO2E DMSLDSOO2E DMSLIOOO2E DMSLKDOO2E DMSLSTOO2E DMSMDPOO2E Dl-1Sl-10DOO2E DMSMVEOO2E DPISNAMOO2E DMSNCPOO2E DMSPOPOO2E DMSPBEOO2E DMSPBTOO2E DMSPUNOO2E DMSRNftOO2E DMSRUNOO2E DMSSLNOO2E DMSSPROO2E DMSSRTOO2E DMSSTTOO2E DMSSYNOO2E Dl-1STPEOO2E DMSTYPOO2E DMSUPDOO2E DMSWFLOO2E DMSWSFOO2E DMSXCTOO2E DMSXGTOO2E DMSXINOO2E DMSXUPOO2E DMSZAPOO2E DMSLGTOO21 DMSLIOOO21 DMSGLBOO2W DMSGNDOO2W DMSLBMOO2W DMSLBTOO2W DMSZAPOO2W DMSACCOO3E DMSAI1S003E DMSABNOO3E Dl-1SARXOO3E DMSASMOO3E DI1SASNOO3E DMSCMPOO3E DMSCPYOO3E DMSDLBOO3E DI1SDLKOO3E DMSDSLOO3E DMSDSVOO3E DMSEDIOO3E DMSERSOO3E DMSFETOO3E DMSFLDOO3E DMSFOROO3E DMSGBNOO3E DMSHLPOO3E DMSICPOO3E DMSIMAOO3E DMSLBDOO3E DMSLBMOO3E DMSLBTOO3E DMSLDSOO3E DMSLIOOO3E DMSLLUOO3E DMSLSTOO3E DMSMODOO3E DMSMVEOO3E DMSNAMOO3E DMSNCPOO3E DMSPOPOO3E DMSPRTOO3E DMSPRVOO3E DMSPUNOO3E DMSRNMOO3E DMSRBVOO3E DMSSBVOO3E DMSSYNOO3E DMSTMAOO3E DMSTPDOO3E DMSTPEOO3E DI1STYPOO3E DMSUPDOO3E DMSUTLOO3E DMSWFLOO3E Dl-1SWNTOO3E DMSWPKOO3E Dl-1SWRCOO3E DMSWRLOO3E DMSWSFOO3E DMSXINOO3E DMSZAPOO3E DMSABNOO4W DMSLKDOO4W DMSCMPOOSE DMSDLBOOSE DMSFOBOOSE DKSLIOOOSE DMSLKDOOSE DKSMODOOSE DKSQBYOO5E DMSTYPOOSE DMSAMSOO6E DMSABNOO6E DMSABXOO6E DMSASMOO6E DMSCMSOO6E DMSDLKOO6E DMSEBVOO6E DMSGENOO6E DMSICPOO6E DMSLKDOO6E DMSLLUOO6E DMSPBVOO6E DMSBBVOO6E DMSSRVOO6E DMSVMFOO6E DMSWNTOO6E DMSWRCOO6E DMSWSFOO6E DMSAMSOO7E DMSARNOO7E DMSARXOO7E DMSASMOO7E DMSDLKOO7E DMSGRNOO7E DMSICPOO7E DMSIFCOO7E DMSLKDOO7E DMSSYNOO7E DMSUPDOO7E DMSXUPOO7E DMSZAPOO7E DMSPBTOO8E Dl-1SPUNOO8E DMSRDCOO8E DMSABNOO8W DMSLKDOO8W DMSCMPOO9E DPISDSKOO9E Dl-1SSBTOO9E DMSTYPOO9E Dl-1SXl-1COO9E DMSXMSOO9E Dl-1SXSEOO9E Dl-1SDSK014E DMSDSL014E Dl'lSGLBO 14E DMSIMA014E Dl-1SLBM014E DMSLBT014E DMSOVB014E DMSPOB014E Dl-1SQRY014E Dl-1SSET014E DMSSPB014E Dl-1STPE014E DMSUTL014E DMSWDF014E DMSZAP014E DMSINT01SE DMSFCH016E DMSABN016W D1'!SLKD016W DMSACC017E Dl-1SAREO 17E DMSFOB017E DMSTPE017E DMSMDP018E DMSCMP019E DMSRNM019E DMSSRT019E DMSDMP020W DMSGND021E DMSLI0021 E DMSMOD021E DMSNCP021E DMSDSV021W DMSGND022E Dl1SDSV022W DMSDLB023E DMSFLD023E DMSIFC023E DMSTPE023E DMSDSV023W DMSARN012W DMSLKD012W DMSCPY024E DMSEDI024E DMSRNM024E DMSSTA024E DMSUPD024E DMSUTL024E DMSXIN024E DMSWRC024E DMSDSV024W DMSIMA013E DMSLBT013E DMSNCP02SE DMSDSV025W DMSCMP010E DMSTPE010E DMSUPD010W Dl-1SCMP011E DMSDOSOO4E DMSFETOO4E DMSLOSOO4E DMSPRVOO4E DMSRRVOO4E DMSSRVOO4E DMSLOS013E Dl-1SNCPO 13E Dl-1SPRT013E DMSPUN013E Dl-1STYP013E Dl-1SDSL013W Dl-1SLBM013W Appendix C. Message-to-Modu1e Cross-Reference 333 DBS DBSQRY026E 1>BSSE1'026E DBSSPR026E DMSDSV026W DBSASN021E DMSDSV027E DBSERV027l!: DMSFl.D027E DMSTLB021E DKSTPE027E DBSDSV027W DKSARE028E DKSASN028E DMSFOB028E DMSDSV028W DMSTPE031E DMSUPD031E DBSXCP031E DMSXCT031E DMSXPT031E DMSISE037E DMSWRC031E DMSARI038E DMSASM038E DBS1CP038E DKSPRT039E DMSPUN039E DMStYP039E DMSUTL039E DMSRNM048E DMSRUN048E DMSSET048E DMSSTT048E DMSTPE048E DMSUPD048E DMSISE048E DMSISU048E DMSWSF048E DKSTYP049E DMSASN050E DKSDLB050E DMSFLDOSOE DMSNXD050E DMSSET050E DMSMOD040E DBSASN029E DIISCftP029E DBSCPt029E D~SEDI029E DMSftVE041E DBSCPY042E DMSRDC042E DKSTPE042E DMSUTL042E DBSFET029E DBSFLD029E DMSLBD029E DMSL10029E DKSPRT029E DftSTPE029! DMSTtP029E DBSX1N029E DIISNAB029E I DBSWDF029E r DKSWPK029E I 'DKSWRC029E DMSBOP043E DMSCLS043E DMSTLB043E DMSTPE043E DBSICP043! DMSCPY030!l DKSRNH030E DMSNCP045E DHSSET031E DKSMOD032E DftSSYN032E DHSUTL032E DBSPRT033E DKSPUN033E DBSSVT033E DBSTYP033E DBSSRT034E DBSASN035E DBSFLD035E DIISVBF035E DKSSOP036E DMSSOP036W DKSBOP037E DBSCl?Y037E DBSDSK037E DBSDSL037E DMSERS037E DBSERV031E DBSPOR037E DMSLBB031E DBSLST037E DBS~OD031E DMSMVE037E DBSPRV037E DKSRDC037E DKSRNII037E DKSSRT037E 334 DHSED1044E DMSPRT044E DHSPUN044E DHSDSL046E DMS1MA046E DHSLBH046E DMSLBT046E DMSDSK047E DBSDSL047E DBSDSV047E DMSGLB041E DftSGL0047E DMS1KA047E DMSl.BM047E DHSLBT047E DMSOVR047E DBSPOP047E DHSPOR047E DBSQRY047E DMSSET047E DKSTPE047E DKSUTL047E DMSVMF041E DHSZAP047E DMSACC048E DMSARE048E DBSCPY048E DftSDLB048E DBSDSI(048E DMSEBS048E DHSPOR048E 1>BSGRN048E DMSLDS048E DHSLST048E DHSIIVE048E DHSPRT048E DMSRNM051E DMSARX052E DMSASM052E DBSOSR052E DMSSRT053E DMSIKS053E DMSCMP054E DMSCPY054E DftSDSK054E DMSED1054E DBSERS054E DHSGRN054E DKSPRT054E DHSPUN054E DHSRDC054E DMSRNM054E DMSSRT054E DMSSTT054E DMSTYP054E DftSUTL054E DKSX1N054E DMSL1OO55E DMSLBM056E OMSLBT056E DBSL10056E DIISNCP056E DHSSYNOS6E DMSWFL054E DHSWSFOS4E DMSZAPOS6E DKSLBTOS6W DHSTMAOS7E DKSTPEOS7E DKSBOPOS8E DHSCLSOS8E DBSTLB058E DMSTPDOS8E DMSTPEOS8E DBSVBFOS8E DMSACCOS9E DBSACC060E DMSSET061E DIISCIIP062E DHSCPY062E I lUI 'VH/SP Systell lIessages and Codes DMSDSK062E DMSPRT062E DMSPUN062E DMSRDC062E DMSRNM062E DHSSRT062E DMSSTT062E DMSTYP062E DHSISU062E DKSWFL062E DMSWNT062E DMSWPK062E DMSWRC062E DMSWRL062E DMSWSF062E DMSCPY063E DMSSRT063E DMSIMS063E DMSCPY064E DMSAKS065E DKSASN065E DMSCPY065E DMSDLB065E DMSDSV065E DKSFLD065E DMSLBD065E DMSUPD065E DMSUTL065E DBSI1N065E DMSAMS066E DMSASN066E DMSCPY066E DMSDLB066E DIISDSV066E DMSFLD066E DMSLBD066E DMSLST066E DMSSYN066E DMSUPD066E DMSUTL066E DKSX1N066E DMSCPY067E DftSCPY068E DMSARE069E DMSASN069E DHSBOP069E DMSCHP069E DMSCPY069E DHSDLB069E DMSDOS069E DMSDSL069E DHSEDI069E DBSEDX069E DMSERS069E DMSFLD0691 DMSFOR069E DMSLDS069E DMSLST069E DMSMVE069E DMSPRT069E DMSPUN069E DMSBNM069E DMSSBT069E DMSSTT069E DIISTYP069E DMSUPD069E DMS DMSVGN069E DMSXSU069E Dl'JSWRC069E DMSWSF069E DMSAMS070E DMSARE070E DMSARX070E DMSASM070E DMSASN070E DMSDLE070E Dl'JSDLK070E DMSDSK070E DMSDSL070E DKSDSV070E DMSERS070E DMSERV070E DMSFET070E DKSFLD070E DMSFOR070E DMSGND070E DMS1CP070E DMS1FC070E DMSLBD070E DMSLBM070E DMSLKD070E DKSLLU070E DMSLST070E DMSMDP070E DMSMOD070E DMSMVE070E DMSNXD070E DMSNXL070E DMSNXM070E DMSOPT070E DMSOSR070E DMSPRT070E DMSPRV070E DMSQRY070E DMSRDR070E DMSRRV070E DMSRUN070E DMSSET070E DMSSRT070E DMSSRV070E DMSSSK070E Dl'JSSTT070E DMSTMA070E DMSTPE070E DMSUPD070E DMSVMF070E DMSVPD070E DMSWFL070E DMSX1N070E DMSZAP070E DMSERS071E DMSEXT072E DMSLOS073E DMSMVE073E DHSUTL073E DMSARX074E DMSASM074E DMSARX075E DMSASM075E DMS1CP075E DMSMVE075E DMSED1076E DMSDSK077E DMSDSK078E Dl'JSGRN078E DMSDSK078W DKS1N1079E DMS1N1080E DMS1N1081E DKSWSF081E DKS1N1082E DMSFET099E DMS1CP099E DMSL1OO99E DMSLLU099E DMSOPT099E DMSPRV099E DMSQRY099E DMSRRV099E DMSSET099E DMSSRV099E DMSNCP099W DKSSRT105S DKSSRV105S DKSTKA105S DKSTPD105S DMSTPE105S DMSUPD105S DMSVMF105S DKSVPD105S DMSXCP105S DKSXCT105S DMSXPT105S DMSETB100E DMS1NS100W DMSSET100W DMSETP106E DMSLBT106S DMS1N1083E DMSKOD084E DMSBTB101E DMSCPY101S DKSEXE085E DMSCPY102S DMSDLB086E DMSMVE086E DMSEOP086W DMSCPY103S DMSASN087E DMSEOP088E DMSCLS088E DKSPDP088E DMSBOP089E DKSCLS089E DKSLOS089E DMSMVG089E DMSOPL089E DMSVLT089E DMSASN090E DMSDOS091E DMSDOS092E Dl'lSDOS093E DMSDOS094E DMSCMS095E DMSDOS095E DMSDSV095E DMSGEN095E DMSTPE096E DMSDOS096S DMSPRV097E DMSRRV097E DMSSRV097E DMSDSL098E DMSFET098E DMSPRV098E DMSRRV098E DMSSRV098E DMSITS098S DMSINS098W DMSSET098W DMSASN099E DMSD1K099E DMSDSV099E DMSERV099E DMSCMP104S DMSDLK104S DMSDSK104S DMSDSL104S DMSED1104S DMSFCH104S DMSGL0104S DKSHLP104S DMSIFC104S DMSLBM104S DMSLBT104S DMSL10104S DMSMOD104S DMSNAM104S DMSNXL104S DMSOVR104S DMSPOP104S DMSPRT104S DMSPUN104S DMSSLN104S DMSSRT104S DMSSYN104S DMSTPE104S DMSTYP104S DMSUPD104S DKSVMF104S DMSXCP104S DMSXCT104S DMSXGT104S DMSXIN104S DMSXMA104S DMSZAP104S DMSBTP105E DMSDLK105S DMSDSK105S DMSDSL105S DMSDSV105S DMSED1105S DMSLBM105S DMS1ET105S D.11S110105S DMS11U105S DMSLST105S DMSMOD105S DMSPOP105S DMSPOR105S DMSPRV105S DMSRDC105S DMSRRV105S DMSBTP107E DMSBWR107S DMSBTP108E DKSGLE108S DMSBTP109E DMSACC109S DMSAMS109S DMSBWR109S DMSCMP109S DMSDLE109S DMSFCH109S DMSHLP109S DMSLBM109S DKSLI0109S DMSKOD109S DMSNCP109S DMSOVR109S DMSPRE109S DMSSMN109S DMSSOP109S DMSSTG109S DMSTMA109S DMSTPD109S DMSVIB109S DMSV1P109S DMSVMF109S DMSVPD109S DMSXBG109S DMSERS109T Dl'JSFNS109T DMSCMS110E DMSGEN110E DMSTLE110S DMSTMA110S DMSTPD110S DMSTPE110S DMSVMF110S DMSVPD110S DMSCMS111E DMSGEN111E DMSTLB111S DMSTPE111S DMSACC112S DMSACC113S DMSAMS113S DMSASN113S DMSBOP113S DMSC10113S DMSC1S113S DMSDEG113S DMSFCH113S DMSFOR113S Appendix C. Message-to-Module Cross-ReE erence 335 nHS DH51'I01135 0"5PR1113S i>~SRIP/11jS DK5TMA137S DKSXSU137S OKSITS137T DMSFRE164T DMSS1'R1961 DMSFRE165T DMSS1'R197S DMSFRE166T DMSSPR198E DMSLBM167S DKSFRE167T DMSSPR199E OMSS1'l{113S DMSS~l'1135 DMSTMA138S DMSITS138T DMSTLB113S D8STPE 113S IHtSVftF113S DHSVP0113S DMsXCt?113S DMSTMA139S DMSITS139T DMSMOD114E OMSFOR1145 DMSCLS140S DMSDAS140S DMSDOS140S DMSITS140T DMSL10169S DKSCMS141 S DMSGEN141S DMS1TP141T DMSC1T171T DMSCRD171T DMSCWR171T DMSSPR204E DMSSET142s DMS1TP142T DMSC1'Y172E DMSDSK205W DMSRDC205W DKSWRL205E DMSFCH115E 0851'1'E1158 DKSLld116S 0"580D116S DMSEDI111s O~SPOW117S ])"5'MF1175 DMSXSC117S OMSDSK118S Oft5PUN118S DMSDOS119s DHSSVT119S DMSS13S120S DMSSCT120S DM8SVT120S OMSZAP200W DMS110168S OMSL10201W DMSL10202W DKSBWR170S OMSL10203W DMSCPY173E DMSED1143S OKSED1143S DKSED1143S DMSITP143T DMSL10206W DMSUPD174W DMSXUP174W DMSEXE175E DMSEDI144S DMS1TP144T DMSZAP208E DMSUPD176W DMSCMP209W DMSC10145S DMS1'10145S DMSSPR145S DMSU1'D1771 DMSUPD1781 DMSXup1781 DMSDLK210E DMSZAP210E DMSUPD210W DMSXUP210W DMSUPD179E DMSXUP179E DMSCMP1791 DMSCMP211E DMSABN148T tHISDOS121s DMSSVT121S DMSABN149T I)MS1T51225 DMSABN150W lntsPRT123S DKSPUN123S DMSUPD207W DMSXU1'207W DMSSRT212E DMSSCR 151 E DMSUPD180W DMSXU1'180W DKSABN152T DMSUPD181E DMSDSL213W DKSLBM213W DMSLBT213W DMSDSK124S OMSBDC124S DKSABN153W DKSUPD182W DKSFOR214W bH5FOR125S 1'>M51'1'5154'1' DM5ERR215'1' DMStOR126S DMSA13N155T DMS1'RE183E DKS01'D183E DKSXUP183E 1)"5M1:81215 DMSCPY156E DMSNAM156E DMSW1'K156E DMSXGT156E DKSU1'D184W DM5XU1'184W DMSDLB220R DMSFLD220R DMSLDS220R IHISMl'E128S b8SMVB1295 DMSMVE1jOS DM5C1'Y157E DMSLBM157S D951N1:1315 DMS01'L158E DftS:8Dll~2S DMSFRE159T b~SXlt;132S DMSDOS160S DMSFRE160T b~SW~K132S 1'HISSMN133s tHfSSTG 1 j3S tU'SI~Sl 34s DMSUPD185W DMSXUP185W DKSU1'D186W DMSXUP186W DMSDLB221E DMSFLD221E DMSLBD221E DMSLDS221E DMSU1'D187E DMSLDS222E DKSZA1'190W DMSLDS223E DKSZA1'191W DMSFLD224E DMSCVH161S DMSD05161S 1'>MSXC1'161s DMSFRE161T DMSZA1'192W DMSMVE2251 DMSZA1'193W DMSLDS226E DMSMVE226I DMSFRE162T DMSSRV194S DMSZA1'194W DMSFRE163T DMSZAP195W DKSITS1355 DMSAMS136S t)I'S!~S136T 336 DMSFOR216E IBII VIt/SP System Messages and codes DMSSTT2271 DMSLDS227W DKS DKSAKS228E DKSDLB307E DKSVGN369E DKSVGN369R DI!!SS~T229E DI!!SBOP308E DKSDLB308E DKSVGN371R DKSXSU229E 0!SLDS2291 DMSOLB3201 D!SVGN380R D!SV1P230E D!SACC230W D!SDLB3211 D!SVGN381R DMSDLB3221 DMSVGN382R D!SDLB3231 DMSVMF383R 0l!!SVPD383R DI!!SST~2281 DKSTLB432E DKSTLB433R DKSTLB434E D!STLB435R DMSTLB4361 DMSTLB4371 D!SLDS231E DI!!Sl'IVE232E DI!!SPRE234E 0!SOLB3241 OMSFL03241 DMSLBD3241 DMSQRY3241 0l!!SPRE235E DMSDLB330R DI!!SLOS2331 DMSPRE236E D!SDLB331R DI!!SPRE237E DMSSET333E DMSPRE238E DMS1MA346E DMSACC240S DMS1!A347E D!SDLK245S DMSDSV245S DMSZAP245S DMS1MA349E OMSZAP246W DMSSLN350E DMSZAP247W DMSSLN351E DMSZAP248W DMSSPR352E DKSZAP2491 DMSVGN360E DKSVGN3601 DMSVGN 360R DMSHLP250S DI!!SHLP251E DKSHLP252E DKSFOll253E DMSSTT253E DMSVGN361E DMSVGN3611 DMSVGN361R DMSSSK362E DMSVGN3621 DMSVGN362R DMSBOP302E DMSDLB302E DMSLLU303E OMSDLB304E DMSUPD3041 DMSXCG5011 DMSBOP403S D!SSEG403S DMSXCG502W DMSBOP404S DKSJ01503E DKSXCG503E DMSXKD503E DMSBOP410S DMSSET410S DMSSSK410S DMSV1B410S DMSXCG504E DMSFCH411S DMSPRV411S DMSRRV411S DMSSRV411S DMSXCP411S DMSCMS412S DMSBOP413S DI!!SDOS413S DMSFLD420E DMS'lMA420E DMS~PD420E DMSXCG505E DMSXCG5061 DMSXCG509W DMSXI!!D5101 DMSXSC5101 DMSXSU5101 DMSXCG511E DMSXCM512E DMSXDC512E DMSPOR513E DMSXCM513E DMSXCM514E DMSTLB422E DMSXSE515E DMSSSK364E OMSVGN3641 DMSVGN364R OMSXCG5171 DMSTLB424E DMSXCG518E DMSTLB425R DMSSSK365E 0l!!SVGN3651 DMSVGN365R DMSXSE519E 0l!!STLB426R DMSTLB4271 DMSVGN366E DMSVGN3661 DMSVGN366R DMSVGN3671 DMSVPD3671 DI!!SAI!!S367R DMS~LB4281 DMSCLS4291 DMSSEB4291 DMSTLB430E DMSDLB30SE DI!!SDLB306E DMSX1N500E DMS~LB4231 DMSUPD300E DMSDLB301E DMSFLE495E DMSTLB421E DMSSSK363E DMSVGN3631 OMSVGN363R DMSIN1260T DMSUPD299E DMSDSK445W DMSDSK496S DI!!SBOP401S D!SDOS401S DMSSET401S DMSV1B401S DMS1KA348E DMSHLP254E OMSEXE255T DMSBOP400S DMSSET400S DI!!SSSK400S DI!!SV1B400S DMSSET444E DMSVGN3681 DMSVPD3681 DI!!SVGN368R DMSTLB431E DI!!STPE431E DMSALT520E DMSCAN520E DMSMOD520E DMSPQU520E DMSSCH520E DMSSOR520E DMSSTA520E DMSXCG520E DMSXCT520E DMSXDC520E DMSXSE520E DMSXCT521E Appendix C. Message-to-Module Cross-Reference 337 DMS DMSXGT521E DMSXSE521E DMSXDC548E DMSXSE548E DMSXCGS221 DMSXDC549E DMSPQU577E DMSNAM618E DMSNXL618E DMSXPT579R DMSNXL619E DMSXPT580W DMSXCT5231 DI1SXDC550E DMSDSK550W DMSXSU582S Dl1SSCH5511 DMSXSU5831 DMSSCH525E DMSXSE525E DMSXSE552E DMSXSU5841 DMSWEX526E Dl1SXCT526E Dl1SXSE526E Dl1SPQO 5531 DMSXED5531 DMSJOI585E DMSSPL585E Dl1SXSU585E DMSXSE524W Dl1SXCT527E DMSXSE528E DMSHEL529E DMSMOD529E DMSPOW529E DMSSCH529E DMSXCT529E DMSXMD529E DMSXML529E DMSXCT554S Dl1SXDC55IJS Dl1SXED55IJS Dl1SXFD 554 S DMSXIN5SQS DMSXMS554S Dl1SXPT554S DMSXSE554S DMSPOP620E Dl1SSCH586E DHSSPL586E DMSXsu586E DMSXMD5871 DMSXSU5871 DMSEI0621E DMSNAM621E DMSEI0622E DMSGL0622E DHSNAM622E Dl1SNXL622E DHSNXM622E DMSNAM622W Dl1SFCH623S DMSFET623S DMSLI0623S DMSNXM6241 DMSNXD624W DMSXSU588E DMSXED555E DMSPOR626E DMSXER556S DMSNXL589E DMSXDS589E DMSPOR627E DMSXSE5301 Dl1SXFC557S DMSXDS590E DI1SGL0628E DI1SICT531E DMSXSE558W DMSXDS591E DMSXCT532E DMSXFD559W DMSXSU559W DMSXMS596S DMSXP'0596S DI1SRDR630S DMSWPl<630S DMSWRC630S DMSXFD560W DMSXSE560W DI1SXOP597E DMKXCT533E DMSXCT534E DI1SGL0631E DMSEI0632E DMSXUP598S DMSXCT535E DMSXCT536E DMSXCT537E DMSHEL561E DMSJOI561E DMSSCH561E DMSSPL561E DMSWEX561E DMSXSS561E DMSNAM633E DMSXUP599S DMSNAM634E DMSCP1'601R DMSNAM6351 DMSCPY602R DMSXSE538E DMSNAM636E DMSJOI562E DMSSPL562E Dl1SXGT562E DMSSRT604R DMSXGT563W DMSFOR60SR DMSJOI56IJW DMSXGT564W DMSINI606R DMSXDC5IJ2E DMSXDC542E DMSXGT565W DMSXDC543E DMSSCH569E DMSXCT539E DMSFOR603R DMSXCT5IJOE DMSXCT541E DMSINI607R DMSNAM637E DMSWDF637E DMSWFL637E DMSWNT637E DHSWPK637E DHSWRC637E DMSWRL637E DMSWSF637E DMSWTL637E DMSINI608R DMSINI640R DI1SINI609R DMSXDC544E DMSALT545E DMSHEL545E DMSMOD545E DMSSCH545E DMSXCT545E DMSXDC545E DMSXMC545E DMSXSE545E Dl1SIDC546E DMSXIN5711 DMSXPT5711 DMSINI610B DMSXI0572E DMSIBI611R DHSXMD5731 DMSINI612R DMSSCH574E DMS!N!.615R DMSJOI575E DMSSPL575E DMSXMC575E DMSXSE57SE DMSNXD616W DMSNXD617E DMSXMC576E DMSEI0618E DMSGL0618E DMSWDF642E DMSXDCS47E 338 DMSWDF641E DMSWPK643E DMSWRC643E I DMSWPK644E I DMSWRC644E DHSWNM645W IBM VM/SP System Messages and Codes DMSWNT6IJ7E DMSWSF647E DMSWTL647E DKS DKSWNT648E DPlSWSF648E DKSWTL648E DKSWSF676E DKSWTL676E DKSIFC826E DKSDI0905S DKSIPC8281 DPlSHLP907T DKSLBK907T DHSLI0907T DftSUTL907T DKSWSF677E DKSGL0649E DKSWNPl649E DPlSWPK649E DMSWRC649E DHSWRL649E DPlSWPK650E DPlSWDC651E DMSWEX651E DMSWFL651E DMSWNT651E DMSWRL651E DKSIFC829W DPlSWSF678E DMSREA830E DKSPNS908T DKSWSF679E DMSIPC831E DftSPNS909T DKSWFL680E DHSWSF680E DKSIPC832S DMSWRC681E DMSCPY901T DftSU1'L901T DHSWRC682E DMSINI902T DMSRDC7011 DHSTPE7011 DHSCPY903T DKSRDC7021 DMSCPY904T DHSRUN999E DMSWDC652E DMSWDC653E DPlSWDF653E DKSGAPl951E DMSGAPl952E DMSGAH953E DMSGAH954E DHSGAH955E DPISGAH956E DMSSTA7031 DMSTPD7031 DPlSWEX654E DPlSWPK655E DHSWRC655E DKSFLD7041 DMSLBD7041 DHSFOR7051 DHSWNM656E DPlSMVE7061 DMSWNH657E DHSWSF657E DHSTPD7071 DftSWNft658W DMSHVE7081 DHSWNH660E DKSWNH660W DMSFET7101 DMSSYN711I DHSWNM662E DMSSYN7121 DHSWNM663W DHSWNH664E DHSCMS7151 DHSGEN7151 DHSWNT665E DHSCPY7211 DHSWNT666E DMSAMS7221 DMSACC7231 DMSWNT667E DMSWSF667E DHSACC7241 DKSWNT668E DHSACC7251 DKSWNT669E DKSACC7261 DKSWNT670E DMSDBG7281 DKSWRC671E DKSWSF671E DHSFOR7321 DMSFOR7331 DKSWPK672E DMSWBC672E DKSWSF672E DMSRDC7381 DMSLI07401 DMSWSF673E DMSZAP7501 DMSWPK674E DKSWRC674E DMSWSF674E DMSZAP7511 DMSFCH777S DHSWSF675E DMSIFC825E Appendix C. Message-to-Hodule Cross-Reference 339 DMT RSCS Message Summary DMTREXOOOI DMTCJ!IIX205E DJ!IITCJ!IIXS51E DMTCJ!IIX101E DJ!IITCMXOO1I DMTCMX206E DJ!IITCJ!IIX552E DMTCMX102E DMTREXOO2I DMTCMX201E DMTCJ!IIX560I DMTCMX103E DMTCMXOO3I DMTCMX208E DMTCMX561E DM1'CMX104E DMTREX091T DJ!IITCMX3001 DJ!IITNPT5101 DMTSML570I DMTCMX105E DMTAXS101I DMTCMX301E DMTCJ!IIX106E DMTAXS102I DMTCMX302E DMTNPT511E DMTSML511E DMTAXS103E DMTCMX303E DMTAXS104I DMTCMX304E DJ!IITNPT580I DMTSML580I DMTAXS105I DMTINI402T DMTAXS106I DMTINI401R DMTAXS1071 DMTINI409R DMTCJ!IIX101E DMTCMX108E DMTCMX709E DMTNPT581E DMTSML581E DMTCMX110E DMTNPT5901 DJ!IITSML590I DMTCMX150E DMTCMX7511 DMTAXS108E DJ!IITNPT108E DMTSML108E DMTINI410R DMTNPT591E DMTSML591E DMTINI431S DMTNPT600I DJ!IITSJ!IIL600I DMTNPT801I DMTSJ!IIL801I DMTNPT141I DMTSML1411 DMTINI479E DMTINI480E DMTNPT610I DMTSML610I DMTNPT802I DMTSML802I DMTNPT142I DJ!IITSML142I DMTINI481E DMTNPT143I DMTSML143I DJ!IITNPT611I DMTSML611I DMTNPT803I DMTSMLB03I DMTINI482E DMTINI483E DJ!IITNPT612E DMTSML612E DMTNPT810E DMTSML810E DMTNPT510I DMTSML510I DMTAXS640I DMTNPTB11E DMTSML811E DMTNPT144I DMTSML144I DMTNPT145I DMTSML145I DMTCMX651I DMTNPT511 E DMTSML511E DMTNPT146I DMTSML146I DMTAXS520I DMTNPT147I DMTSML147I DMTAXS521I DMTNPT149I DMTSML149I DMTCMX152I DMTSML901E DMTCMX6521 DMTCMX6521 DMTNPT902E DMTCMX6531 DMTSML902E DMTCMX6541 DMTNPT903E DMTSML903E DMTAXS522I DMTCMX660I DMTAXs523I DMTNPT904E DMTCMX6611 DMTNPT160I DMTSML160I DMTCMX662I DJ!IITNPT905I DMTSML905I DMTCMX663I DMTSML906E DMTCMX664E DMTNPT907E DMTCMX670I DMTNPT934E DJ!IITSML934E DMTCMX6711 DJ!IITCJ!IIX6121 DMTSML935E DMTCMX6131 DMTNPT936E DMTCMX7001 DMTSML937E DMTAXS524E DMTAXS525E DMTNPT1701 DMTSML170I DMTAXS526E DMTNPT190E DMTSML190E DMTNPT530I DMTCMX540I DMTCMX200I DJ!IITCJ!IIX201E DMTCJ!IIX5411 DMTCJ!IIX542E DJ!IITCMX202E DMTCMX203E DMTCMX543E DMTCMX544E DJ!IITCMX204E DMTCMX550I 340 IBM VM/SP System Messages and Codes DMM IPCS Message Summary DMMGET100S DMMGRC100S DMMINI100S DMMMOD100S Df!MPR0100S DMMREG100S DKMSEA100S DMMSTA100S DMMSUM100S DKKINI200S DKMMAP200S DMKPRM200S DMMPR0200S DMMSTA200S DMMSUM200S DMMWRT200S DMMINI300S DMMPR0300S DMMSTA6011 DMMHEX7141 DMMPRM8041 DMMDSC7001 DMMLOC7151 DMMCPA8051 DMMDSC701R DMMLOC7161 DMMMAP806R DMMFED7021 DMMLOC7171 DMMMAP8071 DMMFED7031 DMMMOD7181 DMMMAP8081 DMMFEX7041 DMMDSC7191 DMMGRC8091 DMMMOD705E DMMDSC7201 DMMMAP8101 DMMMOD7061 DMMDSC721I DMMEDM8501 DMMMOD7071 DMMDSC7221 DMMEDM8511 DMMGET7081 DMMDSC7231 DMMEDM8521 DMMSCR7091 DMMREG7241 DMMEDM8531 DMMTRC7101 DMMINI800S DMMEDM8601 DMMVMB711I DMMMAP8011 DKMEDM8611 DMMIOB7121 DMMMAP8021 DMMEDM863E DMMIOB7131 DMMINI803S DKMEDM8641 DMMINI400S DMMDSC500S DKMSUK501S DMKSUM502S Appendix C. Message-to-Module" Cross-Reference 341 342 IBM VM/SP Syste. Messages and Codes DMK Appendix 0: Message Text-to-Message Identifier Cross-Reference This appendix contains the first lines of all the VM/SP messages, grouped by CP, CMS, RSCS, and IPCS and organized in alphamerical order by message text. Messages starting with a lowercase word such as D~DD!, !1~, and ~§§Iig will have variable information inserted, such messages are listed prior to messages starting with uppercase letters. If you do not issue CP command SET EMSG ON, any messages that are displayed will appear without message identifier, only text. Use this appendix to look up the text of the message and find its identifier, so that you can find the description of the message in the body of the book. .Bm:RSCS and IPCS messages VM/370 Release 6 level. remain at the CP Message Summary DMKNEA122E DMKVDE122E DMKNEA120E DMKVDE120E DMKNEA1:21E DMKVDD121E DMKVDE121E [ PRT [ PRT [ paT [PRT ( PRT ( PRT [PRT ridltype ridltype rid I type ridltype ridltype ridltype ridltype raddr] raddr] raddr] raddr] raddr] raddr] raddr] ALREADY A~TACHED TO userid ALREADY ATTACHED TO userid NeT ATTACHED; userid vaddr ALREADY DEFINED NOT AT'IACHED; userid vaddt ALREADY DEPINED NeT ATTACHED TO userid NOT A'I'IACHED TO userid NeT ATTACHED TO userid DMKTRA182E (reserved for I.BM use) DMKICB7241 [APIMP) RIOBLOCKS REQUESTED IN UNIPROCESSOR DUMP DMKVSP4271 {CONIPRTtPUN} vaddr SYSTEe SPCOL SPACE PULL; FILE CLOSED DMKVST~27I [CONIPRTIPUN} vaddr SYSTEM SPCOL SPACE FULL; JILE CLOSED. DMKCNS5011 {CONIPRTIPUNIRDR} 'addr' INT E!Q (CMD='cm' SNS='sense' CSW='~sw' USERID=luserid'] DMKRSE5011 {CONIPRTIPUNIRDR} 'adar' INT REQ (CMD='cm' SNS='sense' CSW='csw' USERID='userid'] DMKVSP4291 {CONIPRTIPUNIRDR} vaddr SPOCL EEROR; FILa {HELDIPURGED} DMKVST4291 {CONIPRTIPUNIRDB} vaddr SiCCl EEROR; FILE {HELDIPURGJD} DMKCQH024E DMKCSOO24E DMKCSP024E DMKCSQ024E DMKCSU024E DMKCSV024E DMKDEF024E DMKSPT024E {CYLSIBLKSIFORM {CYLSIBLKSIFOBP.I {CYLS I :eLKS I FOBM {CYLSIBLKSIFORM {CYLSI BLKS I FOBM {CYLSIBLKSIFOEM {CYLS I BLKS I FORM {CYLSIBLKSIFOBM NUMEER} NUMBER} NUMBER} NUMBER} NUMBER} NUMEEE} NUMEER} NUeEER} MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSIltG OR OR OR OR OR OR OR OR INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID DMKDAD5081 {DASDIRDRIPRTIPUN} 'addr' PERM ERROR CMD='cm' SNS='sense' CSW='csw' USEBID='userid' [BBCCHH='bbcchh'] DMKDAS508I {DASDIRDRIPETlpUN} 'addr' PEBM EREOR CMD='cm' SNS='sense' CSW='csw' USERID='userid' (BBCCHH='bbcchh'] DMKRSE508I {DASDIRDRIPRTIPUN} 'addr' PEEM ERROR CMD='cm' SNS='sense' CSW='csw' USERID='userid' (EBCCHH='bbcchh'] DMKDAS504D {DASDITAPE} 'addr' DA'IA CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' [EBCCHH='bbcchh') DMKTAP504D {DASDITAPE} 'addr' DA'IA CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' {BBCCHH='bbcchh'} DMKDAD513I {DASDITAPE} laddr' FILE PEOT CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IBICCK='nnnnnn'}] DMKDAS5131 {DASDITAPE} 'addr' FILE PEOT CMD='cm' S~S='sense' CSW='csw' USERID='userid' [ {BBCCHH='bbcchh'IBLOCK='nnnnnn'}] DMKDAS505D {DASDITAPE} 'addr' CVERRUN C~ CMD='cm' SNS=.' sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbcchh' I BLOCK=' nnnnnn'} ] DMKTAP505D {DASDITAPE} 'addr' CVEBRUN CK CMD='cm' SN S=' senae' CSW='csw' USERID='userid' ( {BBCCHH='bbcchh1IELOCK='nnrinnn'}] DMKDAD518I {DASDITAPE{ 'addr' RECV ERROR CMD='cm' SNS='sense' CSW='csw' USERID='userid' ( {BBCCHH=' bbcchh 'I BICCK=' nnnnnn '} ] DMKDAS5181 {DASDITAPE{ ~addr' RECV ERROR CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbcchh ' I EICCK=' nnnnnn '} ] DMKTAP5181 {DASDITAPE{ 'addr' RECV ERROR CMP='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbcchh' I BLOCK=' nnnnnn '} ] Appendix D. Message Text-to-Message Identifier Cross-Reference 343 DKK DMKCFOO46E DKKCFP046E DKKCFS046E DMKCPT046E DMKCPV046E DMKCSE046E DMKCSOO46E DMKDEI046E DKKMCC046E DMKNEA046E DMKNES046E DMKNET046E DKKNLD046E DMKNLE046E DMKSPT046E DMKVDD046E DMKVDEOlJ6E {DEV {DEV {DEV {DEV {DEV {DEV {DEV {DE V {DEV {DEV {DEV {DEV {DEV {DEV {DEV {DEV {DEV ridltype ridltype ridltype ridltype ridltype ridltype ridltype ridltype ridltype ridltype ridltype ridltype ridltype rid Itype ridltype ridltype ridltype raddr} raddr} raddr} raddr} raddr} raddr} raddr} raddr} raddr} raddr} raddr} raddr} raddr} raddr} raddr} raddr} raddr} OFFLINE CFFLINE OFFLINE OPFLINE OPFLINE OFFLINE OFFLINE OFFLINE OFFLINE OFFLINE OFFLINE OFFLINE CFFLINE OFFLINE CFFLINE OFFLINE CFFLINE DMKCFG175E {FAVOREDIRESERVElname} ALREADY IN USE BY userid DKKCF0175E {FAVOREDIRESERVElname} ALEEADY IN USE BY userid DMKCFS175E {FAVOREDIRESERVElname} ALREADY IN USE BY userid DMKGRF5291 DMKRSE5291 DMKGRF525I DMKRSE5251 {GRAFIRDRIPRTIPUN} 'addr' PARI'lY CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' {GRAFIRDRIPRTIPUN} 'addr' PARITY CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' {GRFIRDRIPRTIPUN} 'addr' FORMAT CK CMD='cm' SNS='sense' USERID='userid' {GRFIRDRIPRTIPUN} 'addr' FORMAT CK CMD='cm' SNS='sense' USERID='userid' DMKMCI6181 {INSTRUCTION RETRYIMAIN STORAGE} NOW IN {RECORDIQUIET} MODE cp~id DMKCNS4541 {LINE addrlDEV rid} DISABLED DMKRGA4541 {LINE addrlDEV rid} tISABIED DMKRNH4541 {LINE addrlDEV rid} DISABLED ·DMKBSC5271 DMKCNS5271 DMKBSC528I DMKCNS5281 DMKBSC5171 DMKDAD517I DMKTAP517I (IINEICONS) (LINEICONS) {LINE ICONS) {IINEICONS} {LINEITAPE) (IINEITAPE) {LINEITAPE} 'addr' 'addr' 'addr' 'addr' 'addr' 'addr' 'addr' leST DATA CMD='cm' SNS='sense' CSW='csw' USERID='userid' LOST DATA CMD='cm' SNS='sense' CSW='csw' USERID='userid' TIMEOUT CMD='cm' SNS='sense' CSW='csw' USERID='userid' TIMEOUT CMD='cm' SNS='sense' CSW='csw' USERID='userid' NOT/KNOiN CMD='cm' SNS='sense' CSW='csw' USERID='userid' NCT/KNOiN CMD='cm' SNS='sense' CSW='csw' USERID='userid' NOT/KNOWN CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKTTY152E (PFCOPYIPFTAB) NOT AVAILAELE DMKRSP428E (PRTIPUNIRDRITAPE) raddr SFCOI ERROR; FILE {HELDIPURGED} DMKSPS428E {PRTIPUNIRDRITAPE} raddr SPOOL ERROR; FILE {HELDIPURGED} DMKRSE504A (RDRIPRT) 'addr' DATA CK CMD='cm' SNS='sense' DMKRSE503A {RDRIPRTIPUN} 'addr' EQUIP CK CMD='cm' SNS='sense' DMKRSE5241 {RDRIPRTIPUN} 'addr' LOAD CHECK CMD='cm' SNS='sense' USERID='userid' DMKRSE520A {RDRIPRTIPUN} 'addr' FERM EERCR CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKRS1?426E (RDRI TAPE) raddr SPOOL SPACE FULL; FILE PURGED DMKSPS426E (RDR I TAPE) raddr SPOOL SPACE FULL; FILE PURGED D!'IKCFCOO1E ?CP: command DMKCK1?536I DMKCPI5361 DMKDAD5361 DMKDAS5361 DMKDAU5361 DMKDDR5361 DMKDIR5361 DMKDMP5361 DMKFlIIT5361 DMKSAV536I DMKSSP5361 cuu cuu cuu cuu cuu cuu cuu cuu cuu cuu cuu REPORTS REPORTS REPORTS REPORTS REPORTS REPORTS REPORTS REPORTS REPORTS REPORTS REPORTS DISABLEI DISAEIEI DISABLED DISAEIEI DISABLED DISABLED DISABLED DISABLE}; DISABLED DISAELEI DISABLED INTERFACE; INTERFACE; INTERFACE; INTEBFACE; INTERFACE; INTEBFACE; INTERFACE; INTERFACE; INTERFACE; INTEBFACE; INTERFACE; DMKCPI9521 nnnnnKSYSTElII STOBAGE DlIIKDEI275E raddr ALREADY SY SVIlPI DMKDEI280E raddr ALREADY VIRTUAL 344 IBM.VM/SP System Messages and Codes FAULT FAULT FAULT FAULT FAULT F'AULT FAULT FAULT FAULT FAULT FAULT CODE cccc; NOTIFY CE cccc; NOTIFY CE CODE cccc; NOTIFY CE CODE CODE cccc; NOTIFY CE CODE cccc; NOTIFY CE CODE cccc; NOTIFY CE cccc; NOTIFY CE CODE CODE = cccc; NOTIFY CE cccc; NOTIFY CE CODE CODE cccc; NOTIFY CE cccc; NOTIFY CE CODE DMKDEI277E raddr ERROR DEMOUNTING VOLUME DMKDEI214E raddr HAS A MOUNTED VOLUME. MSS ID NOT AVAILAELE TO DEMOUNT IT DMKDEI276E raddr NOT 3330V DMKBSC5161 type 'addr' BAD SENSE CMD='cm' SNS='sense' [ {BBCCHH='bbcchh'IBLOCK='nnnnnn'}] DMKDAD5161 type 'addr' BAD SENSE CMD='cm' SNS='sense' [ {BBCCHH=' bbcchh ' I EIOCK=' nnnnnn'} ] DMKDAS5161 type 'addr' BAD SENSE CMD='cm' SNS='sense' [{BBCCHH='bbcchh'IELCCK='nnnnnn'} ] DMKTAP5161 type 'addr' EAD SENSE CMD='cm' SNS='sense' ;[ {BBCCHH='bbcchh'IBLOCK='nnnnnn'}] CSW='csw' USERIP=' userid' DMKBSC5021 type 'addr' BUSOUT CK CMD='cm' SNS='SENSE' [ {BBCCHH=' BBCCHH' I ELOCK=' nnnnnn '} ] DMKCNS5021 type 'addr' EUSOUT CK CMD='CM' SNS='SENSE' [ {EBCCHH=' BBCCHH' I BLCCK=' nnnnnn '} ] DMKDAD5021 type 'addr' BUSOUT CK CMD='CM' SNS='SENSE' [ {BBCCHH=' BBCC HH ' I EI CCK=' nnnnnn '} ] DMKDAS5021 type 'addr' BUSOUT CK CMD='CM' SNS='SENSE' [ {BBCCHH=' BBCCHH' I EICCK=' nnnnnn '} ] DMKGRP5021 type 'addr' BUSOUT CK CMD='CM' SNS='SENSE' [ {BBCCHH=' BBCCHH' I ELOCK=' nnnnnn '} ] DMKRSE5021 type 'addr' BUSOUT CK CMD='CM' SNS='SENSE' [ {EBCCHH=' BBCCHH' I ELOCK=' nnnnnn'} ] DMKTAP5021 type 'addr' BUSOUT CK CMD='CM' SNS='SENSE' [ {BBCCHH=' BBCCHH' I EIOCK=' nnnnnn '} ] CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID=' userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID=' userid' DMKBSC5201 type 'addr' CHAN ERROR CMD='cm' SNS='sense' [ {BBCCHH='bbcchh'IEICCK='nnnnnn'}] DMKDAD5201 type 'addr' CHAN ERROR CMD='cm' SNS='sense' [ {BBCCHH='bbcchh'IELOCK='nnnnnn')] DMKDAS5201 type 'addr' CHAN ERROR CMD='cm' SNS='sense' [ {BBCCHH=' bbcchh' I ELOCK=' nnnnnn '} ] DMKRSE5201 type 'addr' CHAN ERROR CMt='cm' SNS='sense' [ (BBCCHH='bbcchh' IELOCK=' nnnnnn')] DMKTAP5201 type 'addr' CHAN ERROR CMD='cm' SNS='sense' [ {BBCCHH=' bbcchh' I EICCK=' nnnnnn '} ] CSW='csw' USERID='userid' DMKBSC5001 type 'addr' CMD REJEC! CMD='cm' SNS='sense' [(BBCCHH='bbcchh'IEICCK='nnnnnn') ] DMKCNS5001 type 'addr' CMD REJECT CMt='cm' SNS='sense' [ {BBCCHH=' bbcchh' I ELOCK=' nnnnnn '} ] DMKDAD5001 type 'addr' CMD REJECT CMD='cm' SNS='sense' [ {BBCCHH=' bbcchh' I BLOCK=' nnnnnn '} ] DMKDAS5001 type 'addr' CMD REJECT CMD='cm' SNS='sense' [ (BBCCHH='bbcchh',BICCK='nnnnnn')] DMKGRP5001 type 'addr' CMD REJECT CMD='cm' SNS='sense' [ {BBCCHH='bbcchh'IELCCK='nnnnnn'}] DMKRSE5001 type 'addr' CMD REJEC! CMD='cm' SNS='sense' [ {BBCCHH='bbcchh'IELOCK='nnnnnn'}] DMKTAP5001 type 'addr' CMD REJECT CMt='cm' SNS='sense' [ {BBCCHH=' bbcchh' I ELOCK=' nnnnnn '} ] CSW='csw' USERID='userid DMKBSC5041 type 'addr' DATA CK CMD='cm' SNS='sense' [(BBCCHH='bbcchh'IEICCK='nnnnnn') ] DMKCNS5041 type 'addr' DATA CK CMD='cm' SNS='sense' [ {EBCCHH='bbcchh'IEIOCK='nnnnnn'}] DMKDAD5041 type 'addr' DATA CK CMD='cm' SNS='sense' [(BBCCHH='bbcchh'IBLOCK='nnnnnn') ] DMKDAS5041 type 'addr' DATA CK CMD='cm' SNS='sense' [ {BBCCHH='bbcchh'IBLOCK='nnnnnn'}] DMKGRF5041 type 'addr' DATA CK CMD='cm' SNS='sense' [ {BBCCHH='bbcchh'IEICCK='nnnnnn'}] DMKRSE5041 type 'addr' DATA CK CMD='cm' SNS='sense' [ (BBCCHH=' bbcchh ' I BLCCK=' nnnnnn ') ] CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSi/='csw' USERID='userid' CSW='csw' USERID='user;l.d CSW='csw' USERID='userid CSW='csw' USERID='userid CSW='csw' USERID='userid CSW='csw' USERID='usericl CSW='csw' USERID='userid CSW='csw' USERID= 'userid' CSW='csw' USERID= 'userid' CSW='csw' USERID= 'userid' CSW='csw' USERID= 'userid' CSW='csw' USERID= 'userid' CSW='csw' USERID= 'userid' DMKBSC5031 type 'addr' EQUIP CK CMD='cm' SNS='sense' CSl/='csw' USERID='userid' [ {BBCCHH='bbcchh'IBICCK='nnnnnn'}] DMKCNS5031 type 'addr' EQUIP CK CMD='cm' SNS='sense' CSi/='csw' USERID='userid' [ (BBCCHH='bbcchh'IBlCCK='nnnnnn')] DMKDAD5031 type 'addr' EQUIP CK CMD='cm' SNS='sense' CSl/='csw' USERID='userid' [ (BBCCHH='bbcchh'IELCCR='nnnnnn')] Appendix D. Message Text-to-Message Identifier cross-Reference 3~5 DMK DMKDAS5031 type 'addr' EQUIP CK CMD='cm' SNS='sense' [ {BBCCHH='bbcchh'IBLOCK=' DDDnDn'J) DMKGRF503I type 'addr' EQUIP CK CMD='cm' SNS='seDse' [ {BBCCHU=' bbcchh' I BICCK=' DDDnDD IJ ) DMKRSE5031 type 'addr'EQUIP CK CMD='cm' SNS='sense' [ (BBCCHH=' bbcchh' I BICCK=' nnnnnn 'J ) DMKTAPS031 type 'addr' EQUIP CK CMD='cm l SNS='sense' [(BBCCHH='bbcchh'IBLCCR='nnnnnn') ) DMKBSC501A type 'addr' INT BEQ C~D='cm' SNS='sense' [ {BBCCRH=fbbcchh'IBLOCK='nnnnnn'J] DMKCNS501A type 'addr' INT REQ CI1D='cm' SNS='sense' [ (BECCHH:;' bbcchh' 1BLOCK=' nnnnnn') ) DMKDAD501A type 'addr' INT EEQ CflD='cm' SNS='sense' [ (BBCcaH=' bbcchh' I BLeCR=' Dnnnnn ') ) DMKDASS01A type 'addr' INT EEQ CMD='cm' SNS='sense' [ (BBCCHH='bbcchh BLceR=' nDnnnn ') ] DMKRSE501A type laddr' INT REQ CMD='cm' SNS=lsense' [ (BBCCHH=' bbcchh ' ,BleCR=' nnnnnn ') ) DMKTAP501A type 'addr' INT REQ CMD='cm' SNS='sense' [ {BBCCHH=' bbcchh ' I BLOCK=' nnDnnn' J ] I, CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' CSW='csw' USERID='userid' DMKGRF5211 type laddr' NO DEVICE CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKRSE5211 type 'addr' NO DEVICE CMD='cm' SNS='sense' CSW='csw' USEEID='userid' DMKTAP521I type 'addr' NO DEVICE CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKBSC5051 type 'addr' OVERRUN CK CMD=lcm' SNS=' sense' [ (BBCCHR=' bbcchh' I BLOCK=' nnnnnn 'J ) DMKCNS505I type 'addr' OVERRUN CK CMD='cm' SNS=' sense' [ (BECCHH=' bbcchh' , BLOeK=' nnnnnn ') ] DMKDAD5051 type 'addr' OVERRUN CK CMD='cm' SNS='sense' [ (BBCCHH=' bbcchh ' I BLCCK=' nnnnnn') ] DMKDASS05I type 'addr' OVERRUN CK CMD='cm' SNS='sense' [ {BBGCHH= 'bbcchh '\ BLOCK=' nnnnnn 'J ] CSW='csw' USERID= 'userid' CSW='csw' USERlD= 'userid' CSW='csw' USERID= 'userid' CSW='csw' USERID= 'userid' DMKDAD5381 type 'addr' PRCG E'BROR CMD='cmd' SNS='sense' CSW='csw' USERID='userid' DMKCFC140E DMKCP0140E DMKCPT140E DMKCPV140E DMl{GS!1LiOE DMKCS0140E DMKMCC140E DMKNES140E PHKNE'X140E DMKNLD140E DMKNLE140E DMKSPT140E DMKVDA140E DMKVDD140E DtlKCP0140E type type type type type type type type type type type type type type type :j;addr raddr raddr raddr raddr raddr raddr raddr raddr raddr raddr raddr raddr raddr raddr DMKGS13148E type raddr. ATTACHED ATTACHED ATTACHED ATTACHED ATTACHED ATTACHED ATTACHED ATTACHED AT'XACHED ATTACHED ATTACHED AT'IACHED AT'tACaED ATTACHED AT'IACHED BUF~ER TO userid TO userid '10 userid TC userid TO userid TC userid '10 userid TO userid '10 userid TO userid 'IO userid TO userid 'IO userid TO userid TO userid LCAD name FAILED DHKCPC049E type raddr IN USE DHKCPOO49E type raddr IN OSE DHKCF0143:E DHKCP0143E PMKCPT143E PMKPEI143E DHKMCC143E DHKNLD143E DMKNLE143E DMKSPT143E DMKVDD143E DMKVDE143E DMKCP0143E type type type type type type type type tYP4i:l type type raddr raddr raddr raddr radar raddr raddr raddr raddr raddr raddr IN IN IN IN IN IN IN IN IN IN IN USE USE USE USE USE USE USE USE USE USE USE BY BY BY BY BY BY BY BY BY BY BY SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM DMKCS01Q1E type raddt NO'! ACTIVE DHKCP0142E type :j;addr NO'I DRiINEO DMKCPT142E type raddr NOT DEAI:NED 346 IBM VM/SP System Hessages a~d Codes DftK DftKCSB142E DftKVDD142E DftKVJ)E142E DftKCP0142E type type type type raddr raddr raddr raddr N01: N01: N01: NO,! DRAINEt DRAINED DRAINEt DRAINED DftKCPS144i type vaddr RESET EY userid DftKDIA047E DftKJ)IB047E DftKLNK104E DftKLNK10SE DftKLlIlK106E DftKLNK107)!! DftKLNK108E DftKLNK109E DftKLNK110E DftKLNK111E DftKLNK112E DftKLNK113E DftKLNK114E DftKLIK118E userid userid userid userid userid userid userid userid userid userid userid userid userid userid vaddr vaddr vaddr vaddr vaddr vaddr vaddr vaddr vaddr vaddr vaddr vaddr vaddr vaddr J)ft~CFS053E DftKCSP053E DftKCSU053E DftKLNK053E DftKLOGOS3E DftKVftD053E userid userid userid userid userid userid NOT NOT NOT NOT NOT NOT IN IN IN IN IN IN DftKCF0045E DftKCPS04SE DftKCPV04SE DftKCQGOq5E DftKCCPOqSE DftKCQROqSE DftKCtY04SE DftKDIAOqSE DftKDIE04SE DftKftSGOqSE DftKSND04SE DftKTHIOqSE DftKTRPOqSE DftKUS004SE DftKVDD04SE userid userid userid userid userid userid userid userid userid userid userid userid userid userid userid userid NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT LOGGED LOGGED LOGGED LOGGED LOGGED LOGGED LOGGED LOGGED LOGGED LOGGED LOGGED LOGGED LOGGED LOGGED LOGGED LOGGED DftKVDEOq~E DOES NOT EXIST DOES NO'! EXIST NOT LINKED; R/O E!Y {nnn OSERSluserid} NOT LINKED: IVi EY {nnn OSERSluserid} NOT LINKED; R/i EY nnn USERS; R/O BY {nnn USERS I userid} NOT LINKED: NOT IN CP DIREC'!ORY NOT lINKED: VOLID volid NOT ftOUNTED NOT LINKED: INVALID LINK DEVICE NOT lINKED; type vaddr ALREADY DEFINED NOT LINKED; NO READ PASSWORD NOT lINKED: NO iRI1:E PASSWORD NOT LINKED: NO ftOL1: PASSWORD NOT LIIKED; FASSWORD INCORRECT NOT LINKED: COftftAND FORftAT NOT VALID CP CP CP CP CP CP DIRECTORY DIRECTORY DI'BECTORY DI'BECTORY DIRECTORY DIRECTORY ON ON ON ON ON 01 ON 01 ON eN 01 ON ON 01 ON 01 DftKftSG057W userid NOT RECEIVING; {DISCONIECTEDI!SG OPPISftSG OFFINOT D1SCINO CONSOLEINOT AUTHORIZEDIWNG OFFIVftCF/IUCV ERROR nnn} DftKCPI92qI xxxx ADDITIONAL FAILING STORAGE FRAftES EXIST DftKCPV92qI xxxx ADDITIONAL PAlLING STORAGE PRAftES EXIST DftKLD092QI xxxx ADDITIONAL FAILING STORAGE PRAMES EXIST D"KCPS1891 AFPINITY NOT SET; SYSTEM IN UNIPROCESSOR 1I0DE DIIKLOG1891 APFINITY NOT SET: SlSTEM IN UNIPROCESSOR ftODE DIIKDEF2581 ALL 3800 DATA CHECKS WILL BE REFLECTED DftKLOG054E ALREADY LOGGED 01 {lIIEIGRAFIIUNA!E} raddr DftKIICT6251 ALTERNATE PROCESSOR RECOVERY SUCCESSFUL; PROCESSOR nn OFFLINE DftKCPI9581 ATTACHED PROCESSOR NOT OPERATIONAL DftKCPI959W ATTACHED PROCESSOR NO'! ONLINE DftKALG059E AUTOLOG FAILED FOE userid-{IPI ftISSINGIIPL FA1LEDIACCOUNT1NG EBROB IINCORRECT PASSWORD} DftKALG11SE AUTOLOG INVALID; EXCESSIVE INCORRECT PASSWORDS DftKCSS0431 BOFFER name DOIS N01: EXIS1: DftKCSB031E BOFPER ftISSING OR INVALID DftKDIA206E CANNOT CONNECT TO HOST VIRTUAL !ACHINE Appendix D. ftessage Text-to-ftessage Identifier Cross-Reference 347 DMK DMKLCH206E CANNOT CONNECT TO HOS~ VIR~UAl BACHINE DMKCDS166E CHANGED SHARED PAGE NCT WEITTEN TO AUXILIARY STORAGE DMKVCH130E DMKVCH147E DMKVCH132E DMKVCH129E DMKVCH048E DMKVCH138E CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL x x x x DMKCCH6051 DMKCPT601E DMKCCH6011 DMKACK603W DMKCCH603W CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL CHECK RECORDING FAILURE CONTROL CHECK DEV xxx; USER 'userid' CONTROL CHECK DEV xxx; USER 'userid' ERROR; RUN SEREP, RESTART SYSTEM ERROR; RUN SEREP, RESTART SYSTEM DMKVCH034E DMKVDE034E DMKVDD134E DMKCPF6231 DMKMCT6231 CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL MISSING OR INVALID MISSING OR INVALID MISSING OR INVALID SET CONNECTED TO A~TACHED PROCESSOR nn SET CONNECTEt TO ATTACHED PROCESSOR nn X X [PROC nn] NO~ A~TACHED TO userid [PROC nn] NO~ ATTACHEt; ALTERNATE PATHS DEFINED ALREADY DEIINED BY userid DEVICES IN USE DOES NO~ EXIST NOT ATTACHEE; INSU!FICIENT FREE STORAGE DMKCS0245E CHARS MISSING OR INVALID DMKCSP245E CHARS MISSING OR INVALID DMKCSU245E CHARS MISSING OR INVALID DMKCKV917E CHECKPOINT AREA INVALID; CLEAR STORAGE AND COLD START DMKCKS919F CHECKPOINT AREA INVALID; CHECKPOINTING TERMINATED DMKCQG028E DMKCQB028E DMKCSE028E DMKCS0028E DMKCSP028E DMKCSU028E DMKSPS028E CLASS CLASS CLASS CLASS CLASS CLASS CLASS MISSING MISSING MISSING MISSING MISSING MISSING MISSING OR OR OR OR OR OR OR INVALID INVALID INVALID INVALID INVALID INVALID INVALID DMKNET157E CLUSTER= PARM MISSING FROM RDEVICE MACRO - DEV raddr DMKLOG067E DMKCFC199E DMKCPV199E DMKDIA 199E DMKLNK199E DMKMCC199E DMKNES199E DMKNET199E DMKNLD199E DMKNLE199E DMKSPT199E DMKVDE199E DMKQVM802E DI1KQVM800E DMKQVM803E DMKQVM809E DMKQVM806E DMKQVM807E COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND FORMAT NOT VALID REJECTED; DEVICE raddr PENDING OFFLINE REJECTED; DEVICE raddr PENDING OFFLINE REJECTED; DEVICE raddr PENDING OFFLINE REJECTED; DEVICE raddr FENDING OFFLINE REJECTED; DEVICE raddr PENDING OFFLINE REJECTED; DEVICE raddr PENDING OFFLINE REJECTED; DEVICE raddr PENDING OFFLINE REJECTED; DEVICE raddr PENDING OFFLINE REJECTED; DEVICE raddr PENDING OFFLINE REJECTED; DEVICE raddr PENDING OFFLINE REJECTED; DEVICE raddr PENDING OFFLINE REJECTED, DEVICES NOT DEDICATED REJECTED, O~BER VIRTUAL MACHINES LOGGED ON REJECTED, SPOCL DEVICES NOT DRAINED REJECTED, TRACE/ADSTOP/CCW TRANS IN EFFECT REJECTED, VIRTUAL ADDRESS NOT EQUAL TO REAL ADDRESS REJECTED, VM/SP A~TACHED PROCESSOR MODE DMKCFG013E DMKCF0013E DMKCQH013E DMKCSE013E DMKCS0013E DMKCSP013E DMKCSU013E DMKCSV013E DMKTRA013E DMKTRP013E DMKVMD013E CONFLICTING CONFLICTING CONFLICTING CONFLICTING CONFLICTING CONFLICTING CONFLICTING CONFLICTING CONFLICTING CONFLICTING CONFLICTING OPTION OPTION OFTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION - option oFtion option opticn option option option option option option opticn DMKPAH415E CONTINUOUS PAGING ERRORS FROM DASD xxx 348 IBM VM/SP System Messages and Codes DBK DMKDDR702E CONTROL STATEMENT SEQUENCE ERROR DMKCS0030E COPIES MISSING OR INVALID DMKCSP030E COPIES MISSING OR INVALID DMKCSU030E COPIES MISSING OR INVALID DMKCPI185E CP ASSIST LEVEL xx DOES NOT MATCH CP LEVEL 11 DMKCF0186E CP ASSIST NOT AVAILAEIE DMKVMA456W DMKDSP450W DMKDSP452W DMKPTR410W DMKPRG453W DMKPRG411W CP CP CP CP CP CP ENTERED; ENTERED; ENTERED; ENTERED; ENTERED; ENTERED; name SHARED PAGE bexloc ALTERED DISAEIED WAIT PSW 'psw' EXTERNAL INTERRUPT LOOP PAGING ERROR PROGRAM INTERRUPT LOOP TRANSIATICN EXCEPTION WHILE IN NON-EC MODE DMKCPI962I CP OWNED DASD cuu VOLID volid INVALID ALLOCATION RECORD DMKVDE9621 CP OWNED DASD cuu VCIID volid INVALID ALLOCATION RECORD DMKCPI9131 CP OWNED VOLID xxxxxx INVALID FOR 3330V DMKDMP9131 CP OWNED VOLID xxxxxx INVALID ~OR 3330V DMKCPl9511 CP VOLID volid NOT MOUNTED DMKTRT3071 DMKTRT3081 DMKTRP306E DMKTRP304E DMKTRP3051 CPTRAP CPTRAP CPTRAP CPTRAP CPTRAP (CP/VIRTUAI) cccc INTER~ACE IGNORED DATA LOST IS ALREADY ACTIVE IS STOPPING, NO INPUT ALlOWED SELECTIVITY RESET DMKDIE058E CTCA vaddr BUSY ON userid DMKRNH4631 CTLR 'raddr' UNIT CHECK; RESTART IN PROGRESS DMKRNH4681 CTLR cuu COMMUNICATICNS SCANNER FAILURE DMKCQP466I CTLR cuu IN BUFFER SLOWDOWN MODE DMKNLD460E DMKNLE460E DMKNLE469E DMKNLD470E DMKNLE470E CTLR CTLR CTLR CTLR CTLR raddr raddr raddr raddr raddr {LOADIDUMPJ {LOADIDUMPJ {LOADIDUMPJ {LOADIDUMPJ {LOADIDUMPJ FAILED: FAILED: FAILED: FAlLEI: FAILED: PROGRAM CHECK PROGRAM CHECK TEMP SPACE NOT AVAILABLE PAGING I/O ERROR PAGING I/O ERROR DMKNLE4641 CTLR raddr CC=3; DEPBESS 370X "lOAD" EUTTON DMKRNH4641 CTLR raddr CC=3; DEPBESS 370X "lOAD" EUTTON DMKNLE471E DMKVDS465W DMKNLD461R DMKNLE461R DKKNLD471E DMKRNH4621 CTLR CTLR CTLR CTLR CTLR CTLR DMKDAS514D DMKDAU5341 DMKDAU5331 DMKDAS517E DASD 'addr' ADDMRK CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' BBCCHH=' bbcchh , DASD 'addr' BKSIZE EX CMD='cm' SNS='sense' CSW='csw' USERID='userid' BLOCK='nnnnnn' DASD 'addr' CHECK DATA CMD='cm' SNS='sense' CSW='csw' USERID='userid' BLOCK='nnnnnn' DASD 'addr' NOT/KNOwN CMD='cm' SNS='sense' CSW='csw' USERID='userid' [ {BBCCHH=' bbccbh' I BLOCK=' nnnnnn '} ] DASD 'addr' SEEK CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' BBCCHH='bbcchh' DASD 'addr' TRKCOND CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' BBCCHH='bbcchh' DASD 'addr' TRKCOND CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' BBCCHH='bbcchh' DASD 'addr' TRKOVERUN CMD='cm' SNS='sense' CSW='csw' USERID='userid' BBCCHH='bbcchh' DASD 'addr' WRT INHIBT CMD='cm' SNS='sense' CSW='csw' USERID='userid' BLOCK='nnnnnn' DMKDAS507D DMKDAD5061 DMKDAS506I DMKDAS5091 DMKDAU5351 raddr raddr raddr raddr raddr raddr DUMP FAILED: UNRECOVERABLE I/O ERROR EMULATOR LINES IN USE BY SYSTEM IPL NOT REQUIRED; ENTER 'YES' TO CONTINUE IPL NOT REQUIRED; ENTER "YES" TO CONTINUE LOAD FAIIEt: UNRECOVERABLE I/O ERROR UNIT CHECK; IPL REQUIRED DMKDAD956A DASD cuu VOLID volid NCT MOUNTEt; NOW OFFLINE DMKDAS956A DASD cuu VOLID volid NCT MOUNTEt; NOW OFFLINE DMKDSB956A DASD cuu VOLID volid NO'I MOUNTED; NOW OFFLINE DMKCPT123E DASD raddr CP CWNED DMKVDD123E DASD raddr CP OWNED DMKVDE123E DASD raddr CP OWNED DMKVDE126E DASD raddr ERROR READING VOLID DMKVDE128E DASD raddr ERROR REAtING ALLCCATION RECORD Appendix D. Message Text-to-Message Identifier Cross-Reference 349 DMK DMKCP0124E DMKCPT124E DMKVDD124E DMKVDE124E DMKCP0124E DASD DASD DASD DASD DASD raddr raddr raddr raddr raddr IN IN IN IN IN USE USE USE USE USE BY BY BY BY BY nnn Dnn nnn nnn Dnn USERS USERS USERS USERS USERS DMKLNK139E DASD raddr NOT {LINKEDIATTACHED}; 3330V NOT ACCEPTED AS SYSTEM VOLUME DMKVDE133E DASD raddr NOT READY DMKSAV351i DASD raddr SYSRES NCT REAtY DMKSAV350i DASD raddr SYSRES VOLID NO! aaaaaa DMKVDE125E DASD raddr VOLID valid ALREAtY ATTACHED TO SYSTEM DMKVDE127E DASD raddr VOLID valid DOES NCT MATCH DMKCPI954E DASD raddr VOLID valid NO! MCUNTED; DUPLICATE OF DASD raddr DMKLNK101W DASD vaddr FORCED RIO; RIO BY {nnn USERSluserid} DMKLNK102W DASD vaddr FORCED RIC; R/i BY {nnn USERSluserid} DMKLNK103W DASD vaddr FORCED RIO; R/i EY {nnn USERSluserid}; RIO BY {nnn USERSluserid} DMKDEF091E DASD vaddr NOT DEFINEt; TEMP SFACE NOT AVAILABLE DMKLCG091E DASD vaddr NOT DEFINED; TEMP SPACE NOT AVAILAELE DMKLNK137E DASD vaddr NOT LINKEt; CHAN x DEtICATED DMKDEI279E DASD NOT VUA DMKCFS205E DAT IGNORE NOT SET; INVALlt TRANSIATICN FORMAT DMKDDF117R DATA DUMPED FROM valid1 TO BE RESTORED TO valid2. DO YOU WISH TO RESPOND YES NO OR REREAD: DMKMID310E DATE date INVALID; NeT CHANGEE DMKVDD213E DETACH REJ VIRTUAL MACHINE TRACING IIO DMKCPT136E DEV {vaddrlraddr} NOT {DEFINEIIVARIED}; CHAN xx DEDICATED DMKDEF136E DEV {vaddrJraddr} NOT {DEFINEDIVARIED}; CHAN xx DEDICATED DMKCFD040E DMKCFG040E DMKCFC040E DMKCPB040E DMKCPT040E DMKCPV040E DMKCCG040E DMKCQP040E DMKCSB040E DMKCS0040E DMKCSP040E DMKCST040E DMKDEF040E DMKDIB040E DMKMCC040E DMKMCt040E DMKNEA040E DMKNES040E DMKNET040E DMKNLt040E DMKNLE040E DMKSPT040E DMKVDt040E DMKVDE040E DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV DEV addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES DOES NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT NOT EXIST EXIST· EXIST EX~ST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST DMKDDE710A DEV cuu INTERVENTION REQUIRED DMKFMT138A DEV cuu INTERVENTION REQUIRED DMKDDE104E DEV cuu NOT OPERATIONAL DMKFMT130E DEV cuu NOT OPERATIONAL OE NOT READY DMKDIE154E DEV cuu NOT OPERATIONAL DMKCPT154E DEV raddr VARY FAILED, VARY IJ PROCESS 350 IBM VM/SP System Messages and Cades CO~TINUE? £!K DMKDIA098E DEV rid MODE SWI'ICH NO'! POSSIELE DMKNES098E DEV rid MODE SWI'ICH NeT PCSSIElE DMKNET098E DEV rid MODE SWI'!CH NOT POSSIELE DMKCPT154E DEV raddr VARY FAILED, VAEY II FROCESS DMKDEE092E DMKLOG092E DMKLOG090E DMKLOG093E DMKDln'095E DMKLOG095E DEV DEV DEV DEV DEV DEV vaddr vaddr vaddr vaddr vaddr vaddr NOT NOT NOT NOT NOT NOT DEFINED; DEFINED; DEFINED; DEFINED; DEFINED; DEFINED; tn: e vaddr ALREADY DEFINED type vaddr ALREADY DEFINED DEV {raddrl volser} NOT AVAILABLE EREOE IN CP DIEECTORY INSUFFICIENT IREE STORAGE INSUFFICIENT FREE STORAGE DMKDEI075E DEVICE 'raddr' IS NOT AVAILAEIE DMKSSS075E DEVICE 'raddr' IS NOT AVAILABLE DMKCPT136E DEVICE (vaddrlraddr) NOT (DEIINEDIVARIED); CHANNEL XX DEDICATED DMKDEF136E DEVICE {vaddrlraddr} NOT {DEFINEDIVARIED}; CHANNEL XX DEDICATED DMKDEF153E DEVICE {vaddrlRNG) EXCEEDED MAX NUMBER OF VIRTUAL DEVICES DMKLNK153E DEVICE (vaddrlRNG) EXCEEDED MAX NUMBER OF VIRTUAL DEVICES DMKVDEt53E DEVICE {vaddrIRNG} EXCEEDED MAX NUMBER OF VIRTUAL DEVICES DMKDEI278E DEVICE NOT A DASD DMKSSS072E DEVICE NOT AVAILAELE - 'raddr' NOT PEOPER TYPE DMKSSS070E DEVICE NOT AVAILABLE - MSS DEVICES ALLOCATED DMKSSS071E DEVICE NOT AVAIIAEIE - MSS CANNOT BE ACCESSED DMKACR149E DEVICE PATH raddr PROC addr PRESENTED cc3 ON I/O REQUEST DMKCSU035E DEVICE TYPE MISSING CR INVAII! DMKDIA707A DIAL FUNCTION NOT AVAILABLE DMKDIR762E DIRECTORY STATEMENT MISSING DMKCPJ9671 DISCONNECT userid - SYSTEM RES'IARTED (mmmnnn) AND SYSTEM CONSOLE NTO VM OPERATOR CONSOLE DMKCSP032E DIST CODE MISSING OR INVALID DMKCSU032E DIST CODE MISSING OR INVALID DMKCDM060E DUMP FAILED; VIRTUAL PEINTEE UNAVAILAELE DMKCDM061E DUMP FAILED; VIRTUAL PRIN'!ER ERROR DMKRND861E DUMP FILE 'filename' NCT IOUNt DMKDIR758E DUPLICATE UNIT DEFINI'IION DMKCFV062E ECMODE NOT SET ON DMKMON2191 END OF MONITOR TAPE, MONI'!OR S'IOPPED EY SYSTEM DMKCKT916E ERROR ALLOCATING SPCCI FILE EUIIERS DMKCKV916E ERROR ALLOCATING SPOOL FILE BUFFERS DMKDDR720E ERROR IN routine DMKDIE764E ERROR IN routine DMKCFS052E ERROR IN CP DIRECTORY DMKINK052E ERROR IN CP DIREC'IORY DMKLOG052E ERROR IN CP DIEECTOEY DMKNMT249E ERROR LOADING IMAG imag DMKMON2201 ERROR ON MONITOR TAPE, MONITOR STOPPED BY SYSTEK DMKIOG5531 ERROR RECORDING AREA CLEARED; USER 'userid' DMKIOG551E ERROR RECORDING AREA FULL; RUN CPEREP. DKKIOF550E ERROR RECORDING AREA 90 PERCENT FULL; RUN CPEREP DMKNKT254E ERROR SAVING imag3800 - Re = (rc) DMKIOH560W ERRORS ON SRF cuu: FRAKES NOT ON ERROR CYLINDERS DMKCPI9231 FAILING STORAGE FRAME AT LOCATION raddr Appendix £. Message Text-to-Kessage Identifier Cross-Reference 351 DMK D!'IKCPV9231 tAILING STORAGE F'RAME AT LOCA'IION raddr D!'IKLD09231 FAILING STORAGE FRAM! AT lOCATION raddr DMKSAV352W FATAL DASD I/O ERROR DMKF!'IT735E FATAL DASD I/O ERROR DMKUDR475I FATAL I/O ERROR TRYING TO READ DIRECTORY DMKRND8521 FATAL I/O ERROR iRITING DUHP DMKCSC246E FCB MISSING OR INVALID DMKCSF246E FCB HISSING OR INVALID DMKCSU246E FCB MISSING OR INVALID D!'IKF!'IT739E FLAGGED PRIMARY TRACR HAS NO ALTERNATE ASSIGNED;IO ERROR FOLLOWS DMKDDR727E FLAGGED 'IRK xxxxxxxxxx HAS NO PROPER ALTERNATE; SKIPPING THIS 'IRK DMKCS0243E FLASH MISSING OR INVALID DMKCSP243E FLASH MISSING OR INVALID DMKCSU243E FLASH MISSING OR INVALID DMKCSF029E FNAME FTYPE MISSING OR INVALID DMKCSU029E FNAME FTYPE MISSING CR INVALID DMKMCD227E FOR OPTION INVALID WITH AUTODISK OFF DMKMCD228E FOR OPTION INVALID ~ITH HCNITCR ON DMKMCD226E FOR VALUE MIDNIGHT - COMMAND INVALID DMKIOG5521 FORMATTING ERROR RECCRtING AREA DMKQVM801E FREE STORAGE PAGE IS NOT AVAILAEIE DMKDDR7291 FULL TRACK READ FEATURE NCT AVAILABLE DMKGRF5311 GRAF 'addr' CNTRL CHECK CMD='cm' SNS='sense' USERID='userid' DMKGRF532I GRAF 'addr' OP CHECK CMD='cm' SNS='sense' USERID='userid' DMKGRF5301 GRAF 'addr' UNIT SPEC CMD='cm' SNS='sense' USERID='userid' DMKCDB160E DMKCDH160E DMKCDS160E DMKCFD160E DMKCPV160E DMKNES160E DMKNET160E DMKVMD160E HEXLOC HEXLOC HEXLOC HEXLOC HEXLOC HEXLOC HEXLOC HEXLOC hexloc hexloc hexloc hexloc hexloc hexloc hexloc hexloc EXCEEDS EXCEEDS EXCEEtS EXCEEDS EXCEEIIS EXCEEDS EXCEEtS EXCEEIIS STOBAGE STORAGE STOpAGE STORAGE STOllAGE STORAGE STOBAGE STORAGE DMKCDS164E HEXIOC hexloc NON-ADIHlESSAEIE STORAGE DMKCFD164E HEXLOC hexloc NON-ADIlRESSABLE STORAGE DMKCFP164E HEXLOC hexloc NON-ADl:RESSAELE STORAGE DHKCDH033E DMKCDS033E DMKCPV033E DMKNET033E DMKVMt033E HEXLOC HEXLOC HEXLOC HEXIOC HEXLOC MISSING MISSING MISSING MISSING MISSING OR OB OR OR OR INVALID INVALID INVALID INVALID INVALID DMKF!'IT736E I/O ERROR cuu {CCHHR=cchhrIBICCK=nnnnnn} SENSE='sense' DMKDDR705E I/O ERROR cuu CSW='csw' SENSE='sense' INPUT={'bbcchh'I'nnnnnn'} OUTPUT='bbcchh' CCW='ccw' D!'IKDIR755E I/O ERROR cuu CSW='csw' SENSE='sense' DMKVER5751 DMKAC0425E DMKCFS086E DMKTRR302E D!'IKRGA7051 I/O I/O I/O I/O I/O ERROR ERROR ERROR ERROR ERROR ADD=raddr, USERID= userid DURING ACCOUNTING ON DASD ON OOC - XIXXXXIIXX RESID=resource id S'IATUS=status LINE=addr D!'IKCS0244E IMAGE LIBRARY MISSING OR lNVAI·ID D!'IKCSB036E INDEX MISSING OR INVALID DMKCPJ9661 INITIALIZATION COMPLETE 352 IBM VM/SP System Messages and Codes D8R DMKDDB72qE INPUT TAPE CONTAINS A CP NUCLEUS DUMP DMKDDB700E INPUT UNIT IS ROT A CFVCL DMKCPI131E DMKLOG131E DMKVDE131E DMKDIA017E DMKCPI955W DMKN!!T256E INSUFFICIENT INSUFFICIENT INSU FFIC lENT INSUFFICIENT INSUFFICIENT INSUFFICIENT FREE STORAGE AVAILABLE FOR (ATTACH I LOGON) REQUEST FREE STORAGE AVAILABLE PCR {ATT Aeft I LOGON} REQUEST FREE STORAGE AVAILABLE FOR ATTACH REQUEST SCREEN SPACE - CLEAB SCREEB AND REDIAL STCBAGE PCR V!VSP VIRTUAL S~ORAGE D!!KCPT602E INTERFACE CONTBCl CHECR DEV DMKCCH6021 INTERFACE CONTROL CHECR DEV xxx~ x~x; USER 'userid' USER 'userid' DMKDID5461 INTERRUPT PENDING pOB {DEVICEICCRTROL UNIT} ceq LAST CSW dc/ck USER id DMKCFH436E INTERRUPT PENDING. !O PROCEBD, TYPE YES. TO END, TYPE NO. D!!KCF0006E DMKCFS006E DMKCFT006E DMKCPE006E DMKCPV006E D!!KCQP006E DMKCSE006E DMKCS0006E DMKCSF006E DMKCST006E DMKCSU006E DMKDIE006E DMKMCC006E DMKNEA006E DMKNES006E DMKNET006E D!!KNLD006E DMKNLE006E DMKSPT006E DMKVDD006E DMKVDE006E D!!KDIA011E DMKDIE011E INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE DMKCDS162E DMKCDS162W DMKDDR719E DMKDIR763E INVALID INVALID INVALID INVALID ECR x - hexdata ECR x - bexdata FILE NAME OE FILE NCT FCUND FILENAME OR FILE NOT FOUND DMKCDS005E INVALID HEXDATA DMKCPEOOSE INVALID HEXDATA DMK~RP005E I~VALID HEXDATA DMKTBR005E INVALID HEXDATA DMKCDBOO4E DMKCDPlOO4E DMKCFCOO4E DMKCFDOO4E DMKCPVOO4E DMKNESOO4E DMKNETOO4E INVALID INVALID INVALID INVALID INVALID INVALID INVALID HEXLOC HEXLOC HEXLOC HEXLOC HEXLOC HEXLOC HEXLOC - - addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr addr userid vaddr userid' vaddr hexdata bexdata hexdata hexdata bexloc bexloc bexloc bexloc hexloc bexloc hexloc D!!KCDSOO4E INVALID HEXLOC - operand DMKDDR708E INVALID INPUT OR CUTPUT DEFINITION DMKMNI225E INVALID MONITOR USERID SPECIFIED, MON NOT ENABLBD DMKF!!IT737E DMKCFCOO2E DMKCFGOO2E DMKCFTOO2E DMKCFWOO2E D!!IKCQSOO2E DMKDDR701E D!!IKDIB751B DMK!!ICCOO2E DMK!!ICDOO2E INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID OPERAND OPERAND OPERANt OPERAND OPERAND OPBRAND OPERAND OPERAND OPERAND OPERANt - o~erand operand o~eJ:and o~erand operand operand operanc:1 operand operand Appendix D. !essage Text-to-!essage Identifier Cross-Reference 353 DMK DMKMNI002E DMKNEA002E DMKNES002E DMKNET002E DMKNLt002E DMKSPT002E DMKTHI002E DMKTRA002E DMKTRP002E DMKTRR002E INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND DMKCDE003E DMKCDM003E DMKCFG003E DMKCF0003E DMKCFS003E DMKCPT003E DMKCPV003E DMKCQP003E DMKCQR003E DMKCSE003E DMKCSC003E DMKCSP003E INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION DMKCS~003E DMKCSU003E DMKDEF003E DMKLCG003E DMKMCC003E DMKMCI003E DMKMSG003E DMKNET003E DMKNLE003E DMKSPT003E DMKTHI003E DMKTRA003E DMKUSC003E DMKVDE003E - operand operand operand operand operand operand operand operand operand operand option option option option option option option option option option option option optio~ option option option option option option option option option option option option option - DMKCPV204E INVALID PAGE(S) SPECIIIED, V=R AREA DMKRND863E INVALID PARAMETER - parameter DMKCDS012E INVALID PSW- psw DMKCPE012E INVALID PSW - psw DMKCDB009E DMKCDM009E DMKCPV009E DMKDEI009E DMKNES009E DMKNET009E DMKVMD009E INVALID INVALID INVALID INVALID INVALID INVALID INVALID RANGE RANGE RANGE RANGE RANGE RANGE RANGE - range range range range range range range DMKCDE010E INVALID REGISTER ~ register DMKCDS010E INVALID REGISTER - register DMKVDA077E INVALID REQUEST FOR DEVICE 'nnn' DMKSPT008E INVALrD SPOOLID ... spoolid DMKCSU008E INVALID SPOOLID - spoolid DMKTRR008E INVALID SPOOLID - spoolid DMKCPV007E INVALID USERID - userid DMKCSP007E INVALID USERID - userid DMKCSU007E INVALID USERID - userid DMKVMI233E DMKVMI234E DMKVMI230E DMKVMI231E DMKVMI232E IPL IPL IPL IPL IPL OVERLAY ERROR SENSE ERROR SIO ERROR TIO ERROR UNIT ERROR; CSW CSW S~S sense DMKCP0198W LAST PATH TO DEVICE radd.r ON PROCESSOR nn 354 IBM VM/SP System Messages and Codes DMK DMKMCD22qE LIMIT MUST BE EETiEEN 10 and 50000 DMKCNSqS51 DMKRGAQSSI DMKCPTOQ9E DMKCPTOQ9E DMKNESOQ9E DMKNETOQ9E DMKNES106E LINE LINE LINE LINE LINE LINE LINE 'addr' NCT OPERATIONAL; text 'addr' NOT OPERATIONAL; text addr IN USE addr IN USE addr IN USE addr IN USE addr NOT ENAELED DMKDIA056E LINE vaddr BUSY ON useIid DMKDIA055E LINE(S) NOT AVAILAEIE eN userid DMKLNK115E LINK INVALID; EXCESSIVE INCORRECT PASSWORDS DMKDDE11SE LOCATION bbcchh IS A FLAGGED !RACK DMKCFOOQ1E LOGMSG nn DOES NOT EXIST DMKMCH6151 MACHINE CHECK RECORDING FAILURE cpuid DMKDDR101E MACHINE CHECK RUN SEREP AND SAVE OUTPUT FOR CE DMKFMT132E MACHINE CHECK RUN SEREP AND SAVE OUTPUT FOR CE DMKDIR151E MACHINE CHECK RUN SEREP AND SAVE OUTPUT FOR Cli DMKMCT6211 DMKMCT6201 DMKMCH6111 DMKMCH61QI DMKMCH62QI DMKACR622W DMKMCH622W DMKMCH6191 DMKMCT6191 DMKMCH609W DMKMCH610W DMKMCT610W DMKMCH611W DMKMCT611W DMKMCH612W DMKMCT612W DMKMCH6161 DMKMCT6161 MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE MACHINE CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; CHECK; AFFINI~Y SET OFF ATTACHED PROCESSCR NOT EEING USED EUFFER OR DLAT DAMAGE cpuid DAMAGED PAGE NOW DELETED cpuid EX~ERNAL DAMAGE MULTIPLE CHANNEL ERRORS MULTIPLE CHANNEL ERRORS OPERA~ION TERMINATED cpuid OPERA~ION ~ERMINATED cpuid PROCESSCR CCNTFOLLER DAMAGE cpuid SUPERVISOR DAMAGE cpuid SUPERVISOR DAMAGE cpuid SYSTEM INTEGRI~Y LOST cpuid SYSTEM INTEGRITY lOST cpuid TIMING FACILITIES DAMAGE; RUN SEREP cpuid TIMING FACILITIES DAMAGE; RUN SEREP cpuid USER userid TERMINATED cpuid USER userid TEEMINATED cpuid DMKSSS01QE MISSING INTERRUPT - DEVICE 'raddr' DMKCSP253E MODIFY MISSING OR INVALID DMKCSU253E MODIFY MISSING OR INVALID DMKMCC215E DMKMCC213E DMKMCD21QE DMKMCD218E DMKMIA229E DMKMCC211E DMKMCD212E DMKMCC211E DMKMCC221E MONITOR MONITOR MONITOR MONITOR MONITOR MONITOR MONITOR MONITOR MONITOR ACTIVE; DASTAP CANNOT BE ENABLED DYNAMICALLY CPTRACE IS ALREADY ACTIVE CPTRACE 15 NO~ AC~IVE NOT STOPPED, CUTSTANDING 1/0 OUT OF DASD PAGES, IS SHUTTING OFF TAPE IS ALREADY ACTIlE TAPE IS NOT ACTIVE TAPE NCT STARTED, NO CLASS ENABLED TO SPOOL IS ALREADY ACTIVE DMKCFV082E MORE THAN ONE VMS AVE AREA ALLCCATED; MUST SPECIFY AREA NAME DMKLOG082E MORE THAN ONE VMSAVE AREA ALLOCATED, MUST SPECIFY AREA NAME DMKIOH561W MORE THAN 50 MCH CR CCH FRAMES WERE READ FROM SRF cuu DMKDDR126E MOVING DATA INTO THE ALTERNATE TRACK CYLINDER(S) IS PROHIBITED DMKSSS0181 MSS MOUNT PROCEEDING FCR VCIUME 'volid' DMKCPU812E MSSF RESPONSE CODE TO VARY CP {ONIOFF} IS nnnn DMKCFS1901 NO AFFINITY SPECIFIED IN DIRECTORY DMKRND8531 NO DUMP FILES EXIST Appendix D. Message Text-to-Message Identifier Cross-Reference 355 DMK DMKCFV080E DHKLOG080E DMKDDR723E DMKDDE716R DMKWRH9201 DMKCPl9681 NO NO NO NO NO NO PREALLOCATED VMSAVE AREA PREALLOCATED VMSAVE AREA VALID CP NUCLEUS eN THE INFUT UNIT VOL1 LABEL FOUND [FOR volser] DO YOU WISH TO CONTINUE? RESPOND YES OR NO OR REREAD: WARM START tATA; CKPT START FOR RETRY WARMSTART, PREVIOUS DA!A STILL VALID DMKCS0441E NOT ACCEPTED. PREVIOUS BACKSPACE STILL BEING PROCESSED DMKDIE760E NOT ENOUGH SPACE ALLOCATED FOR DIRECTORY DMKDDR712E NUMBER OF EXTENTS EXCEEDS 20 DMKTRP309E OPERAND IGNORED SELECT TABLE FULL DMKDDE703E OPERAND MISSING DMKDIR753E OPERAND MISSING DMKCDB026E DMKCDS026E DMKCFC026E DMKCFD026E DMKCFG026E DMKCFH026E DMKCF0026E DMKCFS026E DMKCFT026E DMKCFW026E DMKCPE026E DMKCPT026E DMKCPV026E DMKCQR026E DMKCQY026E DMKCSE026E DMKCSP026E DMKCST026E DMKCSU026E DMKDEF026E DMKDEH026E DMKDEI026E DMKMCC026E DMKMCD026E DMKMCI026E DMKNEA026E DMKNES026E DMKNET026E DMKNLD026E DMKSPM026E DMKSPS026E DMKSPS026E DMKTHI026E DMKTRA026E DMKTRP026E DMKTRE026E OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND OPERAND MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING OR OR OR OR OR OR OR OR OR OR OR OR OR OR OR OR OR OR OR OR OR OR OE OR OR OR OR OR OR OR OR OR OR OR CR OR INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID DMKCPI950A OPERATOR NOT LOGGED ON; EXPLICIT LOGON REQUIRED DMKDDR725R ORIGINAL INPUT DEVICE WAS (IS) LARGER THAN OUTPUT DEVICE. DO YOU WISH TO CONTINUE? RESPOND YES OR NO: DMKDDE718E OUTPUT UNIT IS FILE PROTECTED DMKDDR722E OUTPUT UNIT NOT PROPERLY FORMATTED FOR THE CP NUCLEUS DMKDDE713E OVERLAPPING OR INVALID EXTENTS DMKFMT740E PACK MOUNTED IS 3340-35, NOT 3340-70. MOUNT ANOTHER OR RESPECIFY DMKCPV165I'PAGE hexloc NOT LOCKED; SHARED PAGE DMKRND8641 PAGE REFERENCED NOT AVAILAELE WHILE EDITING xxxxxxxx DMKCFH435E PAGING ERROR WRITING SAVED SYSTEM DMKCFP435E PAGING ERROR WRITING SAVED SYSTEM 356 IBM VM/SP System Messages and Codes DMK DMKSNCQ35E DMKCFG174E DMKDDR038E DMKVMD038E PAGING ERROR ~RITING SAVED SYSTEM PAGING I/O ERROR; IPL FAILED PARAMETER parameter FOR option OPTION MISSING OR INVALID PARAMETER parameter FOR option OPTION MISSING OR INVALID DMKCFG177E DMKLCG050E DMKCKS915E DMKCKV915E PARM EXCEEDS 64 CHARACTERS PASSWORD INCORRECT. REINITIATE LOGON PROCEDURE PERMANENT I/O ERROR eN CHECRPCINT AREA PERMANENT I/O ERROR ON CHECKPOINT AREA DMKCPI9641 PROC xx INITIALIZED; PROC 11 INITIALIZED DMKCPU191E PROCESSOR nn DOES NOT EXIST DMKCPU1941 PROCESSOR nn OFFLINE DMKCPU1931 PROCESSOR nn ONLINE DMKVDA039E PROCESSOR ADDRESS MISSING CR INVALID DMKVDE039E PROCESSOR ADDRESS MISSING OR INVALID DMKDDR756E PROGRAM CHECK PSi DMKDIR756E PROGRAM CHECK PSW DMKFMT756E PROGRAM CHECK PSi psw psw psw DMKRSE242E PRT cuu (3800) INTERVENTION RECQD, STATUS CODE cc DMKRSE240E DMKTCS240E DMKRSE2521 DMKRSE241E DMKTCS241E DMKRSE2551 PRT PRT PRT PRT PRT PRT cuu, cuu, cuu, cuu, cuu, cuu, DMKNEA208E PRT rid FCB-FORMS MISMATCH, EIIEID nnnn {HELDI PURGED] FCB-FORMS MISMATCH, FILEID nnnn {HELD I PURGED] FILE nnnn REQUEUED AND HELD INVALID lOAD MODULE mmmm SPECIFIED, FILE nnnn {HELD I PURGED] INVALID LOAD MODULE mmmm SPECIFIED, FILE nnnn {HELDI PURGED] PAGE BUFFER DESTROYED, BACKUP PAGE COUNT = nnnn NO~ ENABLED DMKTCT270E PRT xxx, TOO MANY WCGM's NEEDED FOR 'CHARS' , FILE nnnn HELD PURGED DMKAC0425A PUN cuu ACCOUNTING tATA; FATAL I/C ERROR DMKCFD021E DMKCFOO21E DMKCPT021E DMKCPU021E DMKCPV021E DMKCQP021E DMKCSB021E DMKCSOO21E DMKDEI021E DMKMCC021E DMKMCt021E DMKNES021E DMKNET021E DMKNLD021E DMKNLE021E Dl'IK SPT021 E RAD'DR RADDR RADDR RADDR RADDR RADDR RADDR RADDR RADDR RADDR RADDR RADDR RADDR RADDR RADDR RADDR MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING lUSSING MISSING MISSING OR OR OR OR OR OR OR OR OR OR OR OR OR OR OR OR INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID DMKVDD021E RADDR MISSING OR INVALID raddr DMKVDE021E RADDR MISSING OR INVALID raddr DMKRSE505A RDR 'addr' OVERRUN CK CMD='cm' SNS='sense' CSi='csw' USERID='userid' DMKRSP434A DMKRSP431A DMKRSPQ32A DMKRSP433A RDR RDR RDR RDR raddr raddr raddr raddr FATAL I/O ERBOR; FILE PURGED 10 CARt MISSING OR INVALID ID CARD; 'userid' NCT IN CP DIRECTORY ID CARD; INVALID DATA - 'data' DMKCST424E RDR FILE SPOOL ERROB; FILE UNCHANGED DMKDDR714E RECORD {bbcchhlnnnnnn] NOT FOUND ON TAPE DMKDDR721E RECORD {cchhrlnnnnnn] NOT FOUND DMKTRR301E REQUESTED FILE IS NCT A CFTRAP FILE DMKNMT257E RESIDUAL BYTE COUNT = nnnnnnnn (HEX) Appendix D. Message Text-to-Message Identifier Cross-Reference 351 DMK DMKCFH300E SAVE REQUEST BEYOND VIRTUAL MACHINE SIZE DHKCPI963I SECOND PROCESSCR NOT CNLINE DHKUS0197E SECONDARY USER IS NOT AVAILABLE DHKLOH196E SECONDARY USER NOT IN CP DIRECTORY DMKSND068E SEND COMMAND FAILED - RECEIVER {IS NO~ DISCONNECTEDIHAS NOT AUTHORIZED SENDERIHAS NO VIRTUAL CONSOLEICONSOLE INPUT WAITING lIS EXECUTING A CONSOLE FUNCTION} DMKCFV063E SHADOW TABLE BYPASS; NCT SET DMKVAT064E SHADOW TABLE BYPASS; RESET DHKCDS161E SHARED PAGE hexloc ALTERED by userid DMKVHA161E SHARED PAGE hexloc ALTERED BY userid DMKATS181E SHARED SYSTEM name REPLACED WITH NON-SHARED COpy DMKSPM8081 SINGLE PROCESSOR MODE ACTIVE DMKSPM805E SINGLE PROCESSCR MODE CFF REJECTED DMKSPM804E SINGLE PROCESSOR MODE ON REJECTED DMKDEF259E SIZE PARAMETER MISSING OR INVALlt DMKMCH6131 SOFT MACHINE CHECK RECORDING DISABLED cpuid DMKNMT248E DMKCF0188E DMKCFS188E DMKLCG188E DMKVCH188E SPECIFIED SPECIFIED SPECIFIED SPECIFIED SPECIFIED IMAGE imag NON-EXISTENT PROCESSOR UNAVAILABLE PROCESSCR UNAVAILAEIE PROCESSOR UNAVAILABLE PROCESSOR UNAVAIIAEIE DMKCKT4381 SPOOL FILE ID LIMIT EXCEEDED DMKCQG042E DMKCST042E DMKCSU042E DMKTRR042E SPOOLID SPOOLID SPOOLID SPOOLID nnnn nnnn nnnn nnnn DOES DOES DOES DOES DMKCQG027E DMKCST027E DMKCSU027E DMKTRR027E SPOOLID SPOOLID SPOOLID SPOOLID MISSING MISSING MISSING MISSING CR OR OR OR NCT NO'I NC'I NOT EXIST EXIS'! EXIST EXIST [OR IS HELD] INVALID INVALID INVALII: INVALID DMKIOHS59W SRF cuu NOT ACCESSIBLE; FRAMES NOT ON ERROR CYLINDERS DMKMCD223E START TIME MUST PRECEDE STOP TIME DMKDIR752E STATEMENT SEQUENCE EEROR FOILCWING USER user DMKCPI9571 STOR sssssK, NUC nnnK, DYN dddddK, TRA tttK, FREE ffffK, V=R vvvvvK DMKDEF094E DMKDEH094E DMKDEF025E DHKDEH025E STORAGE STORAGE STORAGE STORAGE EXCEEDS EXCEEDS HISSING MISSING AllCWED MAXIMUM ALLOWED MAXIMUM CR INVALID OR INVALID DMKCDS163E STORE EXCEEDS MAXIMUM REGISTER DHKMCC216E SYSPROF CLASS IS DEPENDENT ON SCHEDULE AND DASTAP DMKSAV353W SYSRES DEVICE TYPE INVALID DHKCKS400I SYSTEM {TEMP SPACEICHECKPOINT AREA} FULL DMKPGT400I SYSTEM {TEMP SPACEICHECKPCINT AREA} FULL DMKCKT4011 SYSTEM {TEMP SPACEICHECKPCINT AREA} 90 PERCENT FULL DHKCKV4011 SYSTEM {TEMP SPACEICHECKPOINT AREA} 90 PERCENT FULL DHKPGT4011 SYSTEM {TEMP SPACEICHECKPCINT AREA} 90 PERCENT FULL DMKCFG172E SYSTEM name DASD vaddr INCOMPATIBLE SYSRES DMKCFH172E SYSTEM name DASD vaddr INCOMPATIBLE SYSRES 358 IBH VM/SP System Messages and Codes DMK DMKCFG044E DMKCFH044E DMKCFS044E DMKNLt044E DMKSNC044E SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM name name name name name DOES NOT EXIST DOES NO~ EXIS~ DOES NOT EXIST DOES NO~ EXIS~ DOES NO! EXIST DMKSNC178E SYSTEM name EXCEEDS AVAILABLE DASD SPACE DMKCFG170E DMKCFH170E DMKCFS170E DMKNLt170E SYSTEM SYSTEM SYSTEM SYSTEM name EXCEEDS S~CRAGE name EXCEED~ STORAGE name EXCEEDS STCRAGE name EXCEEDS STORAGE DMKCFG173E SYSTEM name REQUIRES DASD. vaddr DMKCFH173E SYSTEM name REQUIRES DASD vaddr DMKCFG171E DMKCFH171E DMKCFS171E DMKNLt171E DMKSNC171~ SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM name name name name name VCLID VOLID VOLID VOLID VCLID valid velid valid valid valid NCT MCUNTED NCT MeUHTED NCT MeUNTED NCT MCUNTED DMKCFG179E DMKCFH179E DMKCFF179E DMKCFS179E DMKSNC179E SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM name name name name name VOLID VOIID VOLID VOIID VOLID velid valid valid valid valid NOT NeT NOT NCT NOT NC~ MCU~TED CF CF CF CF CF OWNED CWNED OWNED CWNED OWNED DMKCF09251 SYSTEM AUTO DUMP REAILCCATED TO DASD raddr DMKDRD9251 SYSTEM AUTO DUMP REALLOCA~ED TO DASD raddr DMKCF09251 SYSTEM AUTO DUMP EEAlleCATED TO DASD raddr DMKDMF909W DMKDMP907W DMKDMP906W DMKDMP905W DMKDMP9181 SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM DUMP DUMP DUMP DUMP DUMP DEVICE NOT-READY FAILURE; FATAL IIC ERROR FAILURE; MACHINE CHECK, RUN SEREP FAILURE; FROGEA~ CHECK FAILURE; STATUS NCT STORED FOR NON-ABENDING PROCESSOR DMKDMP9081 SYSTEM FAILURE; CCDE - code DMKCPI9711 SYSTEM IS [UPIAPIMP] GENERATED DMKCLK437E SYSTEM PAGING SPACE NeT AVAILAELE, IPl TERMINATED DMKCKP900W DMKCKF901W DMKCKP902W DMKCKT903W SYSTEM SYSTEM SYSTEM SYSTEM RECOVERY RECOVERY RECOVERY RECOVERY DMKWRM904W DMKCKT912W DMKCKV912W DMKWRM912W DMKWRM921W DMKCKP922W DMKCKP910W DMKCKF911W SYSTEM RECOVERY SYSTE~ RECOVERY SYSTEM RECOVERY SYSTEM RECOVERY SYSTEM RECOVERY SYSTEM RECOVERY SYSTEM RECOVERY SYSTEM RECOVERY FAIIUEE; FAILURE; FAIIUBE; FAILURE; FBOGFAM CHECK MACHINE CHECK, RUN SEREP FATAL ~O EREOR-{NUCL AREAl WARM AREA) VOLID 'volid'ALLOCATION ERROR (CYLINDER='cylinder'~PAGE='Fag~') FAILURE; FAILURE; FAILURE; FAILURE; FAILURE; FAILURE; FAILURE: FAILURE: INVAlID WARM START DATA 10LID 'volid 1 NOT MCUNTED VOllt 'valid' NOT MOUNTED VOLID 'volid~ NOT MCUNTED UNRECOVERABLE 110 ERROR INVALID SPOOLI~G DATA INVALID WARM START AREA WARM S!ART AREA FUll DMKCKP961W SYSTEM SHUTDOWN COMPLETE DMKCPI961W SYSTEM SHUTDOWN COMPLETE DMKCKP9601 SYSTEM WARM S!ART DATA SAVlD DMKTAP5111 DMKTAP5231 DMKTAP5101 DMKTAF5261 DMKTAP5221 DMKTAP5121 DMKTAP5191 TAPE TAPE TAPE TAPE TAPE TAPE TAPE 'addr' 'addr' 'addr' 'addr' 'addr' 'addr' 'addr' COMPAT CK CMD='c.' SNS='sense' CSW='cs~' USERID='userid CONTlel CKCMC='cm' SNS='sense' CSW=~csw' USERID='userid' CCNVEE! CK CMC='cm'SNS~'sense' CSW='csw' USERID='userid' DSE FAILEt CMD='cm' SNS='sense' CSW='csw' USERID='Userid' ERASE CK CMD='cm' SNS='sense' CSW='csw' USERID='userid' LOAD POINT CMD='cm' SNS='sense' CSW='csw'USERID='userid' PE BURST CMD='cm' SNS='sense' CSW='csw' USERID='userid' DMKSPS014E TAPE raddr DUMP TAPE CAPACITY EXCEEDED DMKSPS037E TAPE raddr INVALID FOR SPTAPE COHMAND DMKRND8511 TEN DUMP FILES ALREADY EXIST Appendix D. Message Text-to-Message Identifier Cross-Reference 359 DMK DMKGRF457E TERMINAL SCRNSAVE UNSUCCESSPUI DMKVDA076E THE 'volid' PARAMETER IS INVALID DMKMCD222E TIME PARAMETER SPECIFIES INVAlID TIM! DMKCFS187E TIMER ASSIST NOT AVAILABLE DMKCLK970W TOD CLOCK SYNC CHECR RECEIVED DMKTRA180W TRACE NOT IN EFFECT DMKCPI9141 TRACE TABLE IS SMALliR THAN REQU!STED DMKTRR3051 TRAPRED SELECTIVITY RESET DMKVDE134E TYPE vaddr NOT ATTACHEt; CHAN X DEDICATED DMKVDA135E TYPE vaddr NOT DETACHED; CHAN X DEDICATED DMKVDD135E TYPE vaddr NOT DETACHEI;CHAN x DEDICATED DMKFMT734E TYPE OR {CYLIPAG} INVALID DMKCF09531 UNABLE TO ALLOCATE SYSTEM AUTO DUMP DMKCPI9531 UNABLE TO ALLOCATE SlSTEM AUTC DUMP DMKRND8501 UNABLE TO READ DUMP FROM READER DMKIOG5581 UNRECOVERABLE I/C ERRCR; ERROE RECORDING DISABLED DMKQCN150A USER userid HAS ISSUED A {CPIVM} READ DMKCPJ229I USER OF MONITOR DOES NOT EXIST DMKLNK117E USERID userid NOT LINKED:VOLID~olid COliFtICT DMKLNK119E USERID vaddr NOT LINKED; INSUFFICIENT FREE STORAGE DMKLNK116E OSERID xxx NOT LINKED; CP tIllECTORY IN OSE DMKCFOO20E DMKCPV020E DMKCQG020E DMKCQP020E DMKCQR020E DMKCQY020E DMKCS1?020E DMKCSOO20E DMKDIA020E DMKDIB020E DMKLNK020E DMKLOG020E DMKMSG020E DMKNEA020E DMKQVM020E DMKSND020E DMKTRP020E DMKUSOO20E DMKVDD020E DMKVDE020E DMKVMD020E USERID USERID USERID USERID USERID USERID USERID USERID USERID USERID USERID USERID USERID USERID USERID USERID USERID USERID USERID USERID USl.:RID MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING OR OR OR OR OR OR OR OR OR Oil OR OR OR OR OR Oil OR OR OR OR OR INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID DMKJRL1451 USERID:userid AT term-raddr WITH INVALID {LINK I LOGON) PASSWORD NO.xxx (psvd) HAS VIOLATED THE LIMIT OF yyy [,A=auseridJ DMKCFG203E V=R AREA REQUIllES I1'L E1 l)!VICE ADDRESS DMKCPV203E V=R AREA REQUIRES !~L EY DI'ICE ADDRESS DMKCFD022E DMKCFG022E DMKCPE022E DMKCQG022E DMKCQP022E DMKCSB022E DMKCSP022E DMKCST022E DMKDEF022E 360 VADDR VADDR VADDR VADDR VADDR VADDR VADDR VADDR VADDR MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING MISSING OR OR OB OB OR OR OR Cll OR INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID IBM VM/SP System Messages and Codes D!K DMKDIA022E VADDR llJISSING OR INVALID DMKDIB022E VADDR MISSING OR INVALID DMKLNK022E VADDR fUSSING OR INVALID DMKVDD022E VADDR MISSING OR INVALID vaddr DMKVDE022E VADDR MISSING OR INVALID vaddr DMKVMI022E VADDR MISSING OR IlnllLID DMKCPT192B VARY PROCESSOR COMMANt PAILBt DMKCP0192E VARY PROCESSOR CC!I!ANt PAllEt DMKCPV176E DMKBLD200E DMKBLD201E DMKBLD202E DMKCPV202E VIRT=REAL VIRT=REAL VIRT=REAL VIRT=REAL VIRT=RBAL AREA AREA AREA AREA AREA IN OSE EY userid NOT AVAILABLE; IN USE EY {useridISYSTEM} NOT AVAILABLE; DAMAGED PAGES NOT AVAILAELE; INSOFFICIENT STORAGE NOT AVAILABLE; INSUPPICIENT STORAGE DMKCFS183E DMKCF0184E DMKCpS184E DMKVMD1461 VM ASSIST NOT ACTIVE VM ASSIST NOT AVAILAELE [CN PROCESSOR proc addr] VM ASSIST NOT AVAIIAElE VMDUMP FAILED, SPOOLING ERROR DMKLOG081W VMSAVE AREA ALREAtY IN US!, MOST USE SET COMMAND DMKCFG083E VMSAVE AREA DOES NOT CONTAIN A VALID SAVED SYSTEM DMKVDE023E DMKFMT733E DMKDIR161E DMKDDR711R VOLID VOLID VOLID VOLID MISSiNG READ IS READ IS READ IS OR INVALID volid1 NOT volid2 volid1 NeT volid2 (ON cuu) volid2 [NOT vOlid1] DO YOU WISH TO CONTINUE? RESPOND YES NO OR REREAD: DMKDDR109E WRONG INPUT TAPE MOUNTED DMKTRR303E OOC READER FILE NeT LeCATAEIE DMKCF0255W 370E FEATURE NOW DISAELED DMKCFS251E 310E IS NOT ACTIVE DMKLOG251E 370B IS NOT ACTIVE DMKCF0250E 370E IS NOT AVAILIEIE (eN PRoe xx) DMKCFS2S0B 310E IS NOT AVAILABLE (ON PROC xx) DMKLCG250B 370E IS NOT AVAILABLE (eN PROC xx) DMt C/) n ~ CD I 0') N -- --- --------_ -----.@ ~I ~ IBM VM/SP: System Messages and Codes SC 19-6204-1 READER'S COMMENT FORM This manual is part of a library that serves as a reference source for systems analysts, programmers, and operators of IBM systems. You may use this form to communicate your comments about this publication, its organization, or subject matter, with the understanding that IBM may use or distribute whatever information you supply in any way it believes appropriate without incurring any obligation to you. Your comments will be sent to the author's department for whatever review and action, if any, are deemed appropriate. Comments may be written in your own language; English is not required. Note: Copies of IBM publications are not stocked at the location to which this form is addressed. Please direct any requests for copies of publications, or for assistance in using your IBM system, to your IBM representative or to the IBM branch office serving your locality. • Does the publication meet your needs? • Did you find the material: Easy to read and understand? Organized for convenient use? Complete? Well illustrated? Written for your technical level? Yes No o o o o o o o o o o o o • What is your occupation? • How do you use this publication: As an introduction to the subject? For advanced knowledge of the subject? To learn about operating procedures? o o o As an instructor in class? As a student in class? As a reference manual? o o o Your comments: If you would like a reply, please supplf your name and address on the reverse side of this form. Thank you for your cooperation. No postage stamp necessary if mailed in the U.S.A. (Elsewhere, an IBM office or representative will be happy to forward your comments or you may mail directly to the address in the Edition Notice on the back of the title page.) SC 19-6204-1 Reader's Comment Form to s: s: .......... < CJ) -c CJ) Please Do Not Staple Fold and Tape Fold and Tape -< en r+ CD 3 I"I s: CD NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES en en Q) co CD en Q) ::l 0- n o 0CD BUSINESS REPLY MAIL FIRST CLASS PERMIT NO. 40 en :::r! CD ARMONK, N.Y. z 9 POSTAGE WILL BE PAID BY ADDRESSEE: CJ) w ...... o .......... I nternational Business Machines Corporation Department G60 P. O. Box 6 Endicott, New York 13760 ~ w o oI ~ -c ~ 3' r+ CD 0::J Fold Fold If you would like a reply, please print: YourName _____________________________________________________ ------- --------- - - ---------~-.. -~- .. ® C ~ ;r> CJ) Company Name ___________________________ Department _______ Street Address _____________________________ City _____________________________________ -n State _ _ _ _ _ _ _ _ _ _ _ _ _ Zip Code ____________ IBM Branch Office serving you ________________________ ~I (0 I en N -
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Create Date : 2012:06:06 16:05:40-08:00 Modify Date : 2012:06:06 17:38:14-07:00 Metadata Date : 2012:06:06 17:38:14-07:00 Producer : Adobe Acrobat 9.51 Paper Capture Plug-in Format : application/pdf Document ID : uuid:9555450d-89d3-4985-8f18-45e875eb36e4 Instance ID : uuid:d6b6b0b8-ee22-4ef9-8924-e6d0763fa8d5 Page Layout : SinglePage Page Mode : UseNone Page Count : 422EXIF Metadata provided by EXIF.tools