SIM800 Series_AT Command Manual_V1.10 Series AT Manual V1.10
SIM800%20Series_AT%20Command%20Manual_V1.10
User Manual:
Open the PDF directly: View PDF .
Page Count: 384
Download | |
Open PDF In Browser | View PDF |
SIM800 Series_AT Command Manual_V1.10 Smart Machine Smart Decision Document Title: SIM800 Series AT Command Manual Version: 1.10 Date: 2016-05-18 Status: Release Document Control ID: SIM800 Series_AT Command Manual_V1.10 General Notes SIMCom offers this information as a service to its customers, to support application and engineering efforts that use the products designed by SIMCom. The information provided is based upon requirements specifically provided to SIMCom by the customers. SIMCom has not undertaken any independent search for additional relevant information, including any information that may be in the customer’s possession. Furthermore, system validation of this product designed by SIMCom within a larger electronic system remains the responsibility of the customer or the customer’s system integrator. All specifications supplied herein are subject to change. Copyright This document contains proprietary technical information which is the property of Shanghai SIMCom Wireless Solutions Ltd, copying of this document and giving it to others and the using or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages. All rights reserved in the event of grant of a patent or the registration of a utility model or design. All specification supplied herein are subject to change without notice at any time. Copyright © Shanghai SIMCom Wireless Solutions Ltd. 2016 SIM800 Series_AT Command Manual_V1.10 2 2016-02-01 Smart Machine Smart Decision Contents Version History ........................................................................................ 14 1 Introduction ........................................................................................... 22 1.1 Scope of the document ....................................................................................... 22 1.2 Related documents ............................................................................................. 22 1.3 Conventions and abbreviations .......................................................................... 22 1.4 AT Command syntax .......................................................................................... 22 1.4.1 Basic syntax ................................................................................................................... 23 1.4.2 S Parameter syntax......................................................................................................... 23 1.4.3 Extended Syntax ............................................................................................................ 23 1.4.4 Combining AT commands on the same Command line ................................................ 23 1.4.5 Entering successive AT commands on separate lines..................................................... 24 1.5 Supported character sets ..................................................................................... 24 1.6 Flow control ....................................................................................................... 24 1.6.1 Software flow control (XON/XOFF flow control) ........................................................ 24 1.6.2 Hardware flow control (RTS/CTS flow control) ........................................................... 25 1.7 Definitions .......................................................................................................... 25 1.7.1 Parameter Saving Mode ................................................................................................. 25 1.7.2 Max Response Time....................................................................................................... 26 2 AT Commands According to V.25TER ............................................... 27 2.1 Overview of AT Commands According to V.25TER ......................................... 27 2.2 Detailed Description of AT Commands According to V.25TER ........................ 28 2.2.1 A/ Re-issues the Last Command Given ...................................................................... 28 2.2.2 ATA Answer an Incoming Call ................................................................................... 28 2.2.3 ATD Mobile Originated Call to Dial A Number ......................................................... 29 2.2.4 ATD>Originate Call to Phone Number in Current Memory ............................... 31 2.2.5 ATD> Originate Call to Phone Number in Memory Which Corresponds to Field ............................................................................................................................... 32 2.2.6 ATDL Redial Last Telephone Number Used ............................................................... 33 2.2.7 ATE Set Command Echo Mode .................................................................................. 34 2.2.8 ATH Disconnect Existing Connection ........................................................................ 35 2.2.9 ATI Display Product Identification Information ......................................................... 35 2.2.10 ATL Set Monitor speaker loudness ........................................................................... 36 2.2.11 ATM Set Monitor Speaker Mode .............................................................................. 36 2.2.12 +++ Switch from Data Mode or PPP Online Mode to Command Mode .................. 36 2.2.13 ATO Switch from Command Mode to Data Mode ................................................... 37 2.2.14 ATP Select Pulse Dialling ......................................................................................... 37 2.2.15 ATQ Set Result Code Presentation Mode ................................................................. 38 2.2.16 ATS0 Set Number of Rings before Automatically Answering the Call .................... 38 2.2.17 ATS3 Set Command Line Termination Character ..................................................... 39 SIM800 Series_AT Command Manual_V1.10 3 2016-02-01 Smart Machine Smart Decision 2.2.18 ATS4 Set Response Formatting Character ................................................................ 39 2.2.19 ATS5 Set Command Line Editing Character ............................................................ 40 2.2.20 ATS6 Pause Before Blind Dialling............................................................................ 41 2.2.21 ATS7 Set Number of Seconds to Wait for Connection Completion .......................... 41 2.2.22 ATS8 Set Number of Seconds to Wait for Comma Dial Modifier Encountered in Dial String of D Command ..................................................................................................... 42 2.2.23 ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier ............. 42 2.2.24 ATT Select Tone Dialing ........................................................................................... 43 2.2.25 ATV TA Response Format ....................................................................................... 43 2.2.26 ATX Set CONNECT Result Code Format and Monitor Call Progress ..................... 44 2.2.27 ATZ Reset Default Configuration ............................................................................. 45 2.2.28 AT&C Set DCD Function Mode ............................................................................... 45 2.2.29 AT&D Set DTR Function Mode ............................................................................... 46 2.2.30 AT&F Factory Defined Configuration ...................................................................... 46 2.2.31 AT&V Display Current Configuration ...................................................................... 47 2.2.32 AT&W Store Active Profile ...................................................................................... 47 2.2.33 AT+GCAP Request Complete TA Capabilities List .................................................. 49 2.2.34 AT+GMI Request Manufacturer Identification ......................................................... 49 2.2.35 AT+GMM Request TA Model Identification ............................................................ 50 2.2.36 AT+GMR Request TA Revision Identification of Software Release ........................ 50 2.2.37 AT+GOI Request Global Object Identification ......................................................... 51 2.2.38 AT+GSN Request TA Serial Number Identification (IMEI) ..................................... 51 2.2.39 AT+ICF Set TE-TA Control Character Framing ....................................................... 52 2.2.40 AT+IFC Set TE-TA Local Data Flow Control .......................................................... 53 2.2.41 AT+IPR Set TE-TA Fixed Local Rate ....................................................................... 54 2.2.42 AT+HVOIC Disconnect Voice Call Only ................................................................. 55 3 AT Commands According to 3GPP TS 27.007 .................................... 56 3.1 Overview of AT Command According to 3GPP TS 27.007 ............................... 56 3.2 Detailed Descriptions of AT Command According to 3GPP TS 27.007 ............ 57 3.2.1 AT+CACM Accumulated Call Meter (ACM) Reset or Query.................................... 57 3.2.2 AT+CAMM Accumulated Call Meter Maximum (ACM max) Set or Query ............. 58 3.2.3 AT+CAOC Advice of Charge ..................................................................................... 59 3.2.4 AT+CBST Select Bearer Service Type........................................................................ 60 3.2.5 AT+CCFC Call Forwarding Number and Conditions Control.................................... 61 3.2.6 AT+CCWA Call Waiting Control ................................................................................ 63 3.2.7AT+CEER Extended Error Report ............................................................................... 64 3.2.8 AT+CGMI Request Manufacturer Identification ........................................................ 67 3.2.9 AT+CGMM Request Model Identification ................................................................. 67 3.2.10 AT+CGMR Request TA Revision Identification of Software Release...................... 68 3.2.11 AT+CGSN Request Product Serial Number Identification (Identical with +GSN) .. 68 3.2.12 AT+CSCS Select TE Character Set........................................................................... 69 3.2.13 AT+CSTA Select Type of Address ............................................................................ 70 3.2.14 AT+CHLD Call Hold and Multiparty ....................................................................... 70 SIM800 Series_AT Command Manual_V1.10 4 2016-02-01 Smart Machine Smart Decision 3.2.15 AT+CIMI Request International Mobile Subscriber Identity.................................... 71 3.2.16 AT+CLCC List Current Calls of ME ........................................................................ 72 3.2.17 AT+CLCK Facility Lock........................................................................................... 73 3.2.18 AT+CLIP Calling Line Identification Presentation ................................................... 75 3.2.19 AT+CLIR Calling Line Identification Restriction..................................................... 76 3.2.20 AT+CMEE Report Mobile Equipment Error ............................................................ 77 3.2.21 AT+COLP Connected Line Identification Presentation ............................................ 78 3.2.22 AT+COPS Operator Selection................................................................................... 80 3.2.23 AT+CPAS Phone Activity Status .............................................................................. 81 3.2.24 AT+CPBF Find Phonebook Entries .......................................................................... 82 3.2.25 AT+CPBR Read Current Phonebook Entries ............................................................ 83 3.2.26 AT+CPBS Select Phonebook Memory Storage ........................................................ 84 3.2.27 AT+CPBW Write Phonebook Entry.......................................................................... 85 3.2.28 AT+CPIN Enter PIN ................................................................................................. 86 3.2.29 AT+CPWD Change Password................................................................................... 87 3.2.30 AT+CR Service Reporting Control ........................................................................... 88 3.2.31 AT+CRC Set Cellular Result Codes for Incoming Call Indication ........................... 89 3.2.32 AT+CREG Network Registration ............................................................................. 90 3.2.33 AT+CRLP Select Radio Link Protocol Parameters ................................................... 92 3.2.34 AT+CRSM Restricted SIM Access ........................................................................... 92 3.2.35 AT+CSQ Signal Quality Report ................................................................................ 93 3.2.36 AT+VTD Tone Duration ........................................................................................... 94 3.2.37 AT+VTS DTMF and Tone Generation...................................................................... 95 3.2.38 AT+CMUX Multiplexer Control............................................................................... 96 3.2.39 AT+CNUM Subscriber Number ............................................................................... 97 3.2.40 AT+CPOL Preferred Operator List ........................................................................... 98 3.2.41 AT+COPN Read Operator Names ............................................................................ 99 3.2.42 AT+CFUN Set Phone Functionality........................................................................ 100 3.2.43 AT+CCLK Clock .................................................................................................... 101 3.2.44 AT+CSIM Generic SIM Access .............................................................................. 101 3.2.45 AT+CALM Alert Sound Mode ............................................................................... 102 3.2.46 AT+CALS Alert Sound Select ................................................................................ 103 3.2.47 AT+CRSL Ringer Sound Level............................................................................... 104 3.2.48 AT+CLVL Loud Speaker Volume Level ................................................................. 104 3.2.49 AT+CMUT Mute Control ....................................................................................... 105 3.2.50 AT+CPUC Price Per Unit and Currency Table ....................................................... 106 3.2.51 AT+CCWE Call Meter Maximum Event ................................................................ 107 3.2.52 AT+CBC Battery Charge ........................................................................................ 108 3.2.53 AT+CUSD Unstructured Supplementary Service Data........................................... 108 3.2.54 AT+CSSN Supplementary Services Notification .................................................... 109 4 AT Commands According to 3GPP TS 27.005 .................................. 112 4.1 Overview of AT Commands According to 3GPP TS 27.005 ........................... 112 4.2 Detailed Descriptions of AT Commands According to 3GPP TS 27.005 ........ 112 SIM800 Series_AT Command Manual_V1.10 5 2016-02-01 Smart Machine Smart Decision 4.2.1 AT+CMGD 4.2.2 AT+CMGF 4.2.3 AT+CMGL 4.2.4 AT+CMGR 4.2.5 AT+CMGS 4.2.6 AT+CMGW 4.2.7 AT+CMSS 4.2.8 AT+CNMI 4.2.9 AT+CPMS 4.2.10 AT+CRES 4.2.11 AT+CSAS 4.2.12 AT+CSCA 4.2.13 AT+CSCB 4.2.14 AT+CSDH 4.2.15 AT+CSMP 4.2.16 AT+CSMS Delete SMS Message ............................................................................ 112 Select SMS Message Format ................................................................. 113 List SMS Messages from Preferred Store.............................................. 114 Read SMS Message............................................................................... 117 Send SMS Message ............................................................................... 120 Write SMS Message to Memory .......................................................... 121 Send SMS Message from Storage .......................................................... 123 New SMS Message Indications .............................................................. 124 Preferred SMS Message Storage ............................................................ 126 Restore SMS Settings............................................................................ 127 Save SMS Settings ................................................................................ 128 SMS Service Center Address ................................................................ 129 Select Cell Broadcast SMS Messages................................................... 130 Show SMS Text Mode Parameters ....................................................... 131 Set SMS Text Mode Parameters ........................................................... 132 Select Message Service ........................................................................ 133 5 AT Commands for SIM Application Toolkit ..................................... 135 5.1 Overview .......................................................................................................... 135 5.2 Detailed Descriptions of Commands ................................................................ 135 5.2.1 AT+STKTRS STK Terminal Response..................................................................... 135 5.2.2 AT+STKENVS STK Envelope Command ............................................................... 136 5.2.3 AT+STKCALL STK call setup ................................................................................. 137 5.2.4 AT+STKSMS STK SMS delivery ............................................................................ 138 5.2.5 AT+STKSS STK SS setup ........................................................................................ 138 5.2.6 AT+STKUSSD STK USSD setup ............................................................................. 139 5.2.7 AT+STKDTMF STK sending DTMF ....................................................................... 139 5.2.8 +STKPCI STK Proactive Command Indication ....................................................... 140 5.2.9 AT+STKMENU STK Main menu command ............................................................ 141 5.2.10 AT+STKPCIS STK URC switch command ............................................................ 141 6 AT Commands Special for SIMCom.................................................. 143 6.1 Overview .......................................................................................................... 143 6.2 Detailed Descriptions of Commands ................................................................ 145 6.2.1 AT+SIDET Change the Side Tone Gain Level....................................................... 145 6.2.2 AT+CPOWD Power off............................................................................................ 146 6.2.3 AT+SPIC Times Remained to Input SIM PIN/PUK ................................................ 146 6.2.4 AT+CMIC Change the Microphone Gain Level ...................................................... 146 6.2.5 AT+CALA Set Alarm Time ..................................................................................... 148 6.2.6 AT+CALD Delete Alarm ......................................................................................... 149 6.2.7 AT+CADC Read ADC ............................................................................................. 149 6.2.8 AT+CSNS Single Numbering Scheme ..................................................................... 150 6.2.9 AT+CDSCB Reset Cell Broadcast ........................................................................... 151 6.2.10 AT+CMOD Configure Alternating Mode Calls ..................................................... 151 SIM800 Series_AT Command Manual_V1.10 6 2016-02-01 Smart Machine Smart Decision 6.2.11 AT+CFGRI Indicate RI When Using URC ............................................................ 152 6.2.12 AT+CLTS Get Local Timestamp ........................................................................... 152 6.2.13 AT+CLDTMF Local DTMF Tone Generation ....................................................... 154 6.2.14 AT+CDRIND CS Voice/Data Call Termination Indication ................................... 155 6.2.15 AT+CSPN Get Service Provider Name from SIM .................................................. 156 6.2.16 AT+CCVM Get and Set the Voice Mail Number on the SIM ................................. 156 6.2.17 AT+CBAND Get and Set Mobile Operation Band ................................................. 157 6.2.18 AT+CHF Configure Hands Free Operation ............................................................ 158 6.2.19 AT+CHFA Swap the Audio Channels ..................................................................... 159 6.2.20 AT+CSCLK Configure Slow Clock ........................................................................ 160 6.2.21 AT+CENG Switch on or off Engineering Mode ..................................................... 161 6.2.22 AT+SCLASS0 Store Class 0 SMS to SIM When Received Class 0 SMS .............. 163 6.2.23 AT+CCID Show ICCID .......................................................................................... 164 6.2.24 AT+CMTE Set Critical Temperature Operating Mode or Query Temperature ...... 164 6.2.25 AT+CMGDA Delete All SMS................................................................................ 165 6.2.26 AT+STTONE Play SIM Toolkit Tone.................................................................... 166 6.2.27 AT+SIMTONE Generate Specifically Tone........................................................... 167 6.2.28 AT+CCPD Enable or Disable Alpha String ........................................................... 168 6.2.29 AT+CGID Get SIM Card Group Identifier............................................................. 168 6.2.30 AT+MORING Show State of Mobile Originated Call ........................................... 169 6.2.31 AT+CMGHEX Enable or Disable Sending Non-ASCII Character SMS ............... 170 6.2.32 AT+CCODE Configure SMS Code Mode.............................................................. 170 6.2.33 AT+CIURC Enable or Disable Initial URC Presentation ....................................... 171 6.2.34 AT+CPSPWD Change PS Super Password ............................................................ 172 6.2.35 AT+EXUNSOL Enable or Disable Proprietary Unsolicited Indications ................. 172 6.2.36 AT+CGMSCLASS Change GPRS Multislot Class ................................................ 173 6.2.37 AT+CDEVICE View Current Flash Device Type .................................................. 174 6.2.38 AT+CCALR Call Ready Query .............................................................................. 174 6.2.39 AT+GSV Display Product Identification Information ............................................ 175 6.2.40 AT+SGPIO Control the GPIO................................................................................. 175 6.2.41 AT+SPWM Generate the Pulse-Width-Modulation ................................................ 176 6.2.42 AT+ECHO Echo Cancellation Control ................................................................... 177 6.2.43 AT+CAAS Control Auto Audio Switch .................................................................. 178 6.2.44 AT+SVR Configure Voice Coding Type for Voice Calls ........................................ 178 6.2.45 AT+GSMBUSY Reject Incoming Call ................................................................... 180 6.2.46 AT+CEMNL Set the List of Emergency Number ................................................... 180 6.2.47 AT*CELLLOCK Set the List of ARFCN Which Needs to Be Locked................... 181 6.2.48 AT+SLEDS Set the Timer Period of Net Light ....................................................... 182 6.2.49 AT+CBUZZERRING Use the Buzzer Sound as the Incoming Call Ring .............. 183 6.2.50 AT+CEXTERNTONE Close or Open the Microphone .......................................... 184 6.2.51 AT+CNETLIGHT Close the Net Light or Open It to Shining ................................ 184 6.2.52 AT+CWHITELIST Set the White List .................................................................... 185 6.2.53 AT+CSDT Switch on or off Detecting SIM Card .................................................. 186 6.2.54 AT+CSMINS SIM Inserted Status Reporting ........................................................ 187 SIM800 Series_AT Command Manual_V1.10 7 2016-02-01 Smart Machine Smart Decision 6.2.55 AT+CSGS Netlight Indication of GPRS Status ..................................................... 188 6.2.56 AT+CMICBIAS Close or Open the MICBIAS ...................................................... 188 6.2.57 AT+DTAM Set TTS and RECORD Play Mode in Call ......................................... 189 6.2.58 AT+SJDR Set Jamming Detection Function ........................................................... 190 6.2.59 AT+CPCMCFG Set PCM Parameter ...................................................................... 192 6.2.60 AT+CPCMSYNC Set PCM Sync Parameter .......................................................... 192 6.2.61 AT+CANT Antenna Detecting ................................................................................ 193 6.2.62 AT+CAGCSET Close or Open AGC Function ....................................................... 194 6.2.63 AT+SD2PCM SD and PCM Switch Function......................................................... 195 6.2.64 AT+SKPD Keypad Detecting Function .................................................................. 196 6.2.65 AT+SIMTONEX Custom Tones ............................................................................... 196 6.2.66 AT+CROAMING Roaming State.............................................................................. 197 6.2.67 AT+CNETSCAN Perform a Net Survey to Show All the Cells’ Information .......... 198 6.2.68 AT+CMNRP Dual Serial Port Feature ................................................................... 199 6.2.69 AT+CEGPRS Switch on or off EDGE ................................................................... 200 6.2.70 AT+CGPIO Control the GPIO by PIN Index .......................................................... 200 6.2.71 AT+CMEDPLAY Play Audio File .......................................................................... 201 6.2.72 AT+CMEDIAVOL Control the Volume when Playing Audio File ......................... 202 6.2.73 AT+SNDLEVEL Set the Sound Level of Special AT Command ............................ 203 6.2.74 AT+ECHARGE Charge Control ............................................................................ 203 6.2.75 AT+SIMTIMER Modify the Poll Interval Time Requested by SIM Card ............. 204 6.2.76 AT+SPE Speech Enhancement Control.................................................................. 205 6.2.77 AT+CCONCINDEX Report Concatenated SMS Index .......................................... 205 6.2.78 AT+SDMODE SD Mode Switch Function ............................................................. 206 6.2.79 AT+SRSPT Control SMS Retransmission ............................................................. 206 6.2.80 AT+CELLIST Perform a Net Survey to Show All the Cells’ Information............. 207 6.2.81 AT+CLIST Query AT ............................................................................................. 208 6.2.82 AT+CBATCHK Set VBAT Checking Feature ON/OFF........................................ 209 7 AT Commands for GPRS Support...................................................... 210 7.1 Overview of AT Commands for GPRS Support ............................................... 210 7.2 Detailed Descriptions of AT Commands for GPRS Support ............................ 210 7.2.1 AT+CGATT Attach or Detach from GPRS Service .................................................. 210 7.2.2 AT+CGDCONT Define PDP Context ....................................................................... 211 7.2.3 AT+CGQMIN Quality of Service Profile (Minimum Acceptable) ........................... 212 7.2.4 AT+CGQREQ Quality of Service Profile (Requested) ............................................. 213 7.2.5 AT+CGACT PDP Context Activate or Deactivate .................................................... 215 7.2.6 AT+CGDATA Enter Data State ................................................................................. 216 7.2.7 AT+CGPADDR Show PDP Address ......................................................................... 216 7.2.8 AT+CGCLASS GPRS Mobile Station Class ............................................................ 217 7.2.9 AT+CGEREP Control Unsolicited GPRS Event Reporting ...................................... 218 7.2.10 AT+CGREG Network Registration Status .............................................................. 219 7.2.11 AT+CGSMS Select Service for MO SMS Messages .............................................. 220 8 AT Commands for TCPIP Application Toolkit.................................. 222 SIM800 Series_AT Command Manual_V1.10 8 2016-02-01 Smart Machine Smart Decision 8.1 Overview .......................................................................................................... 222 8.2 Detailed Descriptions of Commands ................................................................ 223 8.2.1 AT+CIPMUX Start Up Multi-IP Connection ............................................................ 223 8.2.2 AT+CIPSTART Start Up TCP or UDP Connection .................................................. 223 8.2.3 AT+CIPSEND Send Data Through TCP or UDP Connection .................................. 225 8.2.4 AT+CIPQSEND Select Data Transmitting Mode ..................................................... 227 8.2.5 AT+CIPACK Query Previous Connection Data Transmitting State ......................... 228 8.2.6 AT+CIPCLOSE Close TCP or UDP Connection ..................................................... 229 8.2.7 AT+CIPSHUT Deactivate GPRS PDP Context ........................................................ 229 8.2.8 AT+CLPORT Set Local Port ..................................................................................... 230 8.2.9 AT+CSTT Start Task and Set APN, USER NAME, PASSWORD .......................... 231 8.2.10 AT+CIICR Bring Up Wireless Connection with GPRS or CSD ............................. 232 8.2.11 AT+CIFSR Get Local IP Address............................................................................ 232 8.2.12 AT+CIPSTATUS Query Current Connection Status ............................................... 233 8.2.13 AT+CDNSCFG Configure Domain Name Server .................................................. 235 8.2.14 AT+CDNSGIP Query the IP Address of Given Domain Name .............................. 235 8.2.15 AT+CIPHEAD Add an IP Head at the Beginning of a Package Received ............. 236 8.2.16 AT+CIPATS Set Auto Sending Timer ..................................................................... 237 8.2.17 AT+CIPSPRT Set Prompt of ‘>’ When Module Sends Data................................... 238 8.2.18 AT+CIPSERVER Configure Module as Server ...................................................... 238 8.2.19 AT+CIPCSGP Set CSD or GPRS for Connection Mode ........................................ 239 8.2.20 AT+CIPSRIP Show Remote IP Address and Port When Received Data ................ 240 8.2.21 AT+CIPDPDP Set Whether to Check State of GPRS Network Timing .................. 241 8.2.22 AT+CIPMODE Select TCPIP Application Mode ................................................... 242 8.2.23 AT+CIPCCFG Configure Transparent Transfer Mode ........................................... 242 8.2.24 AT+CIPSHOWTP Display Transfer Protocol in IP Head When Received Data .... 244 8.2.25 AT+CIPUDPMODE UDP Extended Mode ............................................................ 244 8.2.26 AT+CIPRXGET Get Data from Network Manually ............................................... 245 8.2.27 AT+CIPSCONT Save TCPIP Application Context ................................................. 247 8.2.28 AT+CIPRDTIMER Set Remote Delay Timer ........................................................ 248 8.2.29 AT+CIPSGTXT Select GPRS PDP context ........................................................... 249 8.2.30 AT+CIPTKA Set TCP Keepalive Parameters ........................................................ 251 9 AT Commands for IP Application ...................................................... 252 9.1 Overview .......................................................................................................... 252 9.2 Detailed Descriptions of Commands ................................................................ 252 9.2.1 AT+SAPBR Bearer Settings for Applications Based on IP ...................................... 252 10 AT Commands for PING Support .................................................... 254 10.1 Overview ........................................................................................................ 254 10.2 Detailed Descriptions of Commands .............................................................. 254 10.2.1 AT+CIPPING PING Request.................................................................................. 254 10.2.2 AT+CIPCTL Set the Mode When Receiving an IP Packet ..................................... 255 10.2.3 AT+CIPFLT Set the Rules of IP Filter .................................................................... 256 SIM800 Series_AT Command Manual_V1.10 9 2016-02-01 Smart Machine Smart Decision 10.2.4 AT+CIPBEIPING Set the Module to be PING or Not............................................ 257 11 AT Commands for HTTP Application ............................................. 259 11.1 Overview ........................................................................................................ 259 11.2 Detailed Descriptions of Commands .............................................................. 259 11.2.1 AT+HTTPINIT Initialize HTTP Service ................................................................. 259 11.2.2 AT+HTTPTERM Terminate HTTP Service ............................................................ 260 11.2.3 AT+HTTPPARA Set HTTP Parameters Value ........................................................ 260 11.2.4 AT+HTTPDATA Input HTTP Data ......................................................................... 262 11.2.5 AT+HTTPACTION HTTP Method Action ............................................................. 262 11.2.6 AT+HTTPREAD Read the HTTP Server Response ............................................... 264 11.2.7 AT+HTTPSCONT Save HTTP Application Context .............................................. 265 11.2.8 AT+HTTPSTATUS Read HTTP Status ................................................................... 266 11.2.9 AT+HTTPHEAD Read the HTTP Header Information of Server Response .......... 267 12 AT Commands for FTP Application ................................................ 268 12.1 Overview ........................................................................................................ 268 12.2 Detailed Descriptions of Commands .............................................................. 269 12.2.1 AT+FTPPORT Set FTP Control Port ...................................................................... 269 12.2.2 AT+FTPMODE Set Active or Passive FTP Mode .................................................. 269 12.2.3 AT+FTPTYPE Set the Type of Data to Be Transferred .......................................... 270 12.2.4 AT+FTPPUTOPT Set FTP Put Type ....................................................................... 271 12.2.5 AT+FTPCID Set FTP Bearer Profile Identifier ....................................................... 271 12.2.6 AT+FTPREST Set Resume Broken Download ....................................................... 272 12.2.7 AT+FTPSERV Set FTP Server Address .................................................................. 272 12.2.8 AT+FTPUN Set FTP User Name ............................................................................ 273 12.2.9 AT+FTPPW Set FTP Password............................................................................... 274 12.2.10 AT+FTPGETNAME Set Download File Name .................................................... 275 12.2.11 AT+FTPGETPATH Set Download File Path......................................................... 275 12.2.12 AT+FTPPUTNAME Set Upload File Name ......................................................... 276 12.2.13 AT+FTPPUTPATH Set Upload File Path ............................................................. 276 12.2.14 AT+FTPGET Download File ................................................................................ 277 12.2.15 AT+FTPPUT Set Upload File ............................................................................... 278 12.2.16 AT+FTPSCONT Save FTP Application Context .................................................. 279 12.2.17 AT+FTPDELE Delete Specified File in FTP Server ............................................. 280 12.2.18 AT+FTPSIZE Get the Size of Specified File in FTP Server ................................. 281 12.2.19 AT+FTPSTATE Get the FTP State ........................................................................ 282 12.2.20 AT+FTPEXTPUT Extend Upload File .................................................................... 282 12.2.21 AT+FTPMKD Make Directory on the Remote Machine ...................................... 283 12.2.22 AT+FTPRMD Remove Directory on the Remote Machine .................................. 284 12.2.23 AT+FTPLIST List Contents of Directory on the Remote Machine ...................... 284 12.2.24 AT+FTPGETTOFS Download File and Save in File System ............................... 285 12.2.25 AT+FTPPUTFRMFS Upload File from File System. ........................................... 286 12.2.26 AT+FTPEXTGET Extend Download File ............................................................ 288 SIM800 Series_AT Command Manual_V1.10 10 2016-02-01 Smart Machine Smart Decision 12.2.27 AT+FTPFILEPUT Load File in RAM from File System then Upolad with FTPPUT ................................................................................................................................ 289 12.2.28 AT+FTPQUIT Quit Current FTP Session ............................................................. 290 13 AT Commands for GSM Location Application ............................... 291 13.1 Overview ........................................................................................................ 291 13.2 Detailed Descriptions of Commands .............................................................. 291 13.2.1 AT+CIPGSMLOC GSM Location and Time ............................................................ 291 14 AT Commands for Email Application .............................................. 293 14.1 Overview ........................................................................................................ 293 14.2 Detailed Descriptions of Commands .............................................................. 294 14.2.1 AT+EMAILCID Set Email Bearer Profile Identifier.............................................. 294 14.2.2 AT+EMAILTO Set Timeout Value of SMTP/POP3 Server Response .................. 294 14.2.3 AT+SMTPSRV Set SMTP Server Address and Port ............................................. 295 14.2.4 AT+SMTPAUTH Set User Name and Password for SMTP Authentication.......... 296 14.2.5 AT+SMTPFROM Set Sender Address and Name .................................................. 297 14.2.6 AT+SMTPRCPT Set the Email Recipient(TO/CC/BCC) Address and Name ....... 298 14.2.7 AT+SMTPSUB Set the Email Subject ................................................................... 299 14.2.8 AT+SMTPBODY Set the Email Body ................................................................... 299 14.2.9 AT+SMTPFILE Set the Email Attachment ............................................................ 300 14.2.10 AT+SMTPSEND Send the Email ......................................................................... 301 14.2.11 AT+SMTPFT Transfer the Email Attachment ...................................................... 302 14.2.12 AT+SMTPCS Set the Email Charset .................................................................... 303 14.2.13 AT+POP3SRV Set POP3 Server and Account ..................................................... 304 14.2.14 AT+POP3IN Log in POP3 Server ........................................................................ 305 14.2.15 AT+POP3NUM Get Email Number and Total Size ............................................. 305 14.2.16 AT+POP3LIST Get the Specific Email Size ........................................................ 306 14.2.17 AT+POP3UIDL Get the Specific Email Unique-id .............................................. 307 14.2.18 AT+POP3CMD Get Multi-line Response ............................................................ 308 14.2.19 AT+POP3READ Read Multi-line Response ........................................................ 310 14.2.20 AT+POP3DEL Mark the Specific Email to Delete .............................................. 311 14.2.21 AT+POP3RSET Unmark the Emails that Be Marked as Deleted ........................ 312 14.2.22 AT+POP3OUT Log Out POP3 Server ................................................................. 313 15 AT Commands for MMS Application .............................................. 314 15.1 Overview ........................................................................................................ 314 15.2 Detailed Descriptions of Commands .............................................................. 315 15.2.1 AT+CMMSCURL Set the URL of the MMS Center ............................................. 315 15.2.2 AT+CMMSPROTO Set the Protocol Parameter and MMS Proxy ......................... 315 15.2.3 AT+CMMSCID Set the Network Parameters for MMS......................................... 316 15.2.4 AT+CMMSSENDCFG Set the Parameters for Sending MMS .............................. 317 15.2.5 AT+CMMSEDIT Enter or Exit Edit Mode ............................................................ 318 15.2.6 AT+CMMSDOWN Download the File Data or Title from UART ........................ 319 SIM800 Series_AT Command Manual_V1.10 11 2016-02-01 Smart Machine Smart Decision 15.2.7 AT+CMMSDELFILE Delete the File of the Edited MMS by File Index .............. 320 15.2.8 AT+CMMSSEND Start MMS Sending .................................................................. 321 15.2.9 AT+CMMSRECP Add Recipients ......................................................................... 322 15.2.10 AT+CMMSCC Add Copy Recipients .................................................................. 322 15.2.11 AT+CMMSBCC Add Secret Recipients .............................................................. 323 15.2.12 AT+CMMSDELRECP Delete Recipients ............................................................ 324 15.2.13 AT+CMMSDELCC Delete Copy Recipients ....................................................... 324 15.2.14 AT+CMMSDELBCC Delete Secret Recipients ................................................... 325 15.2.15 AT+CMMSRECV Receive MMS ........................................................................ 326 15.2.16 AT+CMMSVIEW Get the MMS into Buffer and Show the Information............. 327 15.2.17 AT+CMMSREAD Read the Given File of the MMS in the Buffer ..................... 328 15.2.18 AT+CMMSRDPUSH Read the Information of the MMS PUSH Message.......... 328 15.2.19 AT+CMMSUA Set User Agent ............................................................................ 330 15.2.20 AT+CMMSPROFILE Set User Agent Profile ...................................................... 331 15.2.21 AT+CMMSTIMEOUT Set MMS Timeout .......................................................... 331 15.2.22 AT+CMMSSTATUS Get MMS Status ................................................................ 332 15.2.23 AT+CMMSINIT Initialize MMS Function .......................................................... 333 15.2.24 AT+CMMSTERM Exit MMS Function ............................................................... 333 15.2.25 AT+CMMSSCONT Save MMS Context ............................................................. 334 16 AT Commands for DDET Application............................................. 336 16.1 Overview ........................................................................................................ 336 16.2 Detailed Descriptions of Commands .............................................................. 336 16.2.1 AT+DDET DTMF Detection Control..................................................................... 336 17 AT Commands for RECORD Application ....................................... 338 17.1 Overview ........................................................................................................ 338 17.2 Detailed Descriptions of Commands .............................................................. 338 17.2.1 AT+CREC Record Operation ................................................................................. 338 17.2.2 AT+CRECORD Record and Send Data to UART .................................................. 341 18 AT Commands for TTS Application ................................................ 343 18.1 Overview ........................................................................................................ 343 18.2 Detailed Descriptions of Commands .............................................................. 343 18.2.1 AT+CTTS TTS Operation....................................................................................... 343 18.2.2 AT+CTTSPARAM Set Parameters of the TTS Playing .......................................... 344 18.2.3 AT+CTTSRING Enable/Disable TTS Play During Incoming Call Ring................ 345 19 Supported Unsolicited Result Codes ................................................ 346 19.1 Summary of CME ERROR Codes ................................................................. 346 19.2 Summary of CMS ERROR Codes ................................................................. 349 19.3 Summary of Unsolicited Result Codes .......................................................... 353 20 AT Commands Examples ................................................................. 358 SIM800 Series_AT Command Manual_V1.10 12 2016-02-01 Smart Machine Smart Decision 20.1 Profile Commands .......................................................................................... 358 20.2 SIM Commands .............................................................................................. 359 20.3 General Commands ........................................................................................ 362 20.4 Call Control Commands ................................................................................. 362 20.5 SIM Toolkit Commands ................................................................................. 365 20.6 Audio Commands ........................................................................................... 365 20.7 SMS Commands ............................................................................................. 365 20.8 GPRS Commands ........................................................................................... 366 20.9 TCPIP Commands .......................................................................................... 369 20.10 IP Commands ............................................................................................... 369 20.11 PING Commands.......................................................................................... 369 20.12 HTTP and FTP Commands .......................................................................... 371 20.13 GSM Location Commands ........................................................................... 371 20.14 EMAIL Commands ...................................................................................... 371 20.15 MMS Commands ......................................................................................... 372 20.16 DDET Commands ........................................................................................ 373 20.17 RECORD Commands................................................................................... 374 20.18 TTS Commands ............................................................................................ 376 21 ATC Differences among SIM800 Series .......................................... 377 21.1 AT+SIDET ...................................................................................................... 377 21.2 AT+CMIC ....................................................................................................... 377 21.3 AT+CBAND ................................................................................................... 378 21.4 AT+CHFA ....................................................................................................... 378 21.5 AT+SGPIO ..................................................................................................... 379 21.6 AT+SJDR ........................................................................................................ 379 21.7 AT+CREC....................................................................................................... 380 21.8 AT+CTTSPARAM ......................................................................................... 380 21.9 AT+CADC ...................................................................................................... 380 21.10 AT+CSCLK .................................................................................................. 380 21.11 AT+CMMSDOWN ....................................................................................... 381 21.12 AT+CFGRI ................................................................................................... 381 21.13 AT+CLCK .................................................................................................... 382 21.14 Only Part of Projects Support Following AT Commands ............................ 382 SIM800 Series_AT Command Manual_V1.10 13 2016-02-01 Smart Machine Smart Decision Version History Version Date Chapter What is new V1.00 V1.01 New version 2013-07-23 All Modify GSM 07.05 to 3GPP TS 27.005,modify GSM 07.07 to 3GPP TS 27.007 1.1 Scope of the document Add SIM800 2.2.8 ATH Delete ATH parameter [n] 2.2.12 +++ Change "0.5 second" to "1 second" 2.2.13 ATO Change "NO CARRIER" to "ERROR" 2.2.26 ATX Change default value from 0 to 4 2.2.32 AT&W Add AT+CFGRI,AT+CSGS 2.2.41.1 Auto-bauding Disable DTR auto-bauding 3.2.14 AT+CHLD Delete parameter of CHLD 3.2.18 AT+CLIP Change URC parameter 3.2.51 AT+CRSL Delete reference Note 3.2.7 AT+CEER Change description of 34 (emergency call not possible) 4.2.10 AT+CRES Delete description of CSCB 4.2.11 AT+CSAS Delete description of CSCB 6.2.4 AT+CMIC Add reference Note 6.2.11 AT+CFGRI Add default value 6.2.16 AT+CCVM Modify Test Command response information and parameter description 6.2.18 AT+CHF Add URC 6.2.26 AT+STTONE Change supported range;delete reference note 6.2.27 AT+SIMTONE Modify last parameter of Test Command to 10-500000 6.2.48 AT+SLEDS Modify default value 6.2.55 AT+CSGS Add ATC 6.2.56 AT+CMICBIAS Add ATC 8.2.2 AT+CIPSTART Modify parameter 8.2.15 AT+CIPHEAD Modify parameter 8.2.20 AT+CIPSRIP Modify parameter 8.2.23 AT+CIPCCFG Modify write cmd parameters 8.2.26 AT+CIPRXGET Add "single IP & multi IP connection" information SIM800 Series_AT Command Manual_V1.10 14 2016-02-01 Smart Machine Smart Decision 9.2.1 AT+SAPBR Modify parameter 12.2.23 AT+FTPLIST Change "Execution Command" to "Write Command" 14.2.8 AT+SMTPBODY Change "Execution Command" to "Write Command" 14.2.10 AT+SMTPSEND Modify parameter 14.2.11 AT+SMTPFT Change "Execution Command" to "Write Command" 15.2.15 AT+CMMSRECV Change reference note 15.2.21 AT+CMMSTIMEOUT Change "milliseconds" to "seconds" 15.2.25 AT+CMMSSCONT Modify parameter of Execution Command 17.2.1 AT+CREC Add note 18.2.2 AT+CTTSPARAM Modify parameter;add note 20.8 GPRS Commands Modify the CGQREQ example 20.17 RECORD Commands Add example 3.2.17 AT+CLCK Add Max Response Time 3.2.22 AT+COPS Add Max Response Time 3.2.29 AT+CPWD Add Max Response Time 3.2.28 AT+CPIN Add Max Response Time 3.2.41 AT+VTS Add Max Response Time 3.2.44 AT+CPOL Add Max Response Time 3.2.45 AT+COPN Add Max Response Time 3.2.54 AT+CPUC Add Max Response Time 6.2.7 AT+CADC Add Max Response Time 6.2.23 AT+CCID Add Max Response Time 7.2.1 AT+CGATT Add Max Response Time 7.2.5 AT+CGACT Add Max Response Time 3.2.24 AT+CPBF Modify description of max response time 3.2.25 AT+CPBR Modify description of max response time 4.2.1 CMGD Modify description of max response time 4.2.3 CMGL Modify description of max response time 6.2.25 CMGDA Modify description of max response time 15.2.8 AT+CMMSSEND Modify description of max response time 15.2.15 AT+CMMSRECV Modify description of max response time 2.2.16 ATS0 Add parameter saving mode 2.2.20 ATS6 Add parameter saving mode 2.2.21 ATS7 Add parameter saving mode SIM800 Series_AT Command Manual_V1.10 15 2016-02-01 Smart Machine Smart Decision V1.02 2013-10-23 2.2.22 ATS8 Add parameter saving mode 2.2.26 ATX Add parameter saving mode 3.2.4 AT+CBST Add parameter saving mode 3.2.16 AT+CLCC Add parameter saving mode 3.2.12 AT+CSCS Add parameter saving mode 3.2.51 AT+CRSL Add parameter saving mode 3.2.52 AT+CLVL Add parameter saving mode 6.2.33 AT+CIURC Add parameter saving mode 6.2.53 AT_CSDT Add parameter saving mode 6.2.54 AT+CSMINS Add parameter saving mode 3.2.32 AT+CREG Modify parameter save mode 6.2.44 AT+SVR Modify parameter save mode 7.2.10 AT+CGREG Modify parameter save mode 3.2.24 AT+CPBS Delete parameter save mode 3.2.25 AT+CPBW Delete parameter save mode 2.2.28 AT&C Modify the format 3.2.5 AT+CCFC Change error word: to 3.2.33 AT+CRLP Add Save mode and reference 3.2.36 AT+FCLASS Modify information about +FCLASS 3.2.47 AT+CCLK Add note 4.2.5 AT+CMGS Add Note 6.2.18 AT+CHF Modify parameter range and note 6.2.19 AT+CHFA Add patameters of write command and test command,modify note 6.2.20 AT+CSCLK Add new parameter and note 6.2.24 AT+CMTE Increase the temperature range 6.2.28 AT+CCPD Set default value 6.2.33 AT+CIURC Set default value 6.2.41 AT+SPWM Modify parameter direction and note 6.2.51 AT+CNETLIGHT Add test and read command 6.2.53 AT+CSDT Modify note 6.2.55 AT+CSGS Modify parameter default value 6.2.56 AT+CMICBIAS Add default value and modify parameter description 6.2.57 AT+DTAM Add AT command 6.2.58 AT+SJDR Add AT command 6.2.59 AT+CPCMCFG Add AT command 6.2.60 AT+CPCMSYNC Add AT command SIM800 Series_AT Command Manual_V1.10 16 2016-02-01 Smart Machine Smart Decision V1.03 2014-03-28 6.2.61 AT+CANT Add AT command 6.2.62 AT+CAGCSET Add AT command 7.2.9 AT+CGEREP Modify parameter description and add URC example 8.2.7 AT+CIPSHUT Add Max Response Time 8.2.10 AT+CIICR Add Max Response Time 8.2.21 AT+CIPDPDP Modify parameter’s scope 8.2.26 AT+CIPRXGET Modify parameter options 16.2.1 AT+DDET Add parameter and URC description in write command,add note 17.2.1 AT+CREC Modify note 17.2.2 AT+CRECORD Add AT command 18.2.2 AT+CTTSPARAM Modify note and parameter default value 20.16 AT+DDET Modify AT+DDET example 21.5 AT+CTTSPARAM Add differences of some AT commands 21.6 AT+CHFA Add differences of some AT commands AT+CEXTHS,AT+CEXBUT Delete All Add or modify Parameter Saving Mode and Max Response Time 1.1 Scope of the document Add SIM800G 2.2.28 AT&C Modify parameter format 2.2.32 AT&W Modify parameter stored by &W 2.2.41 AT+IPR Add parameter description 3.2.6 AT+CCWA Modify decription 3.2.24 AT+CPBS Add “FD” phonebook 3.2.46 AT+CALS Add parameter for playing/stopping tone 5.2.1 AT+STKTRS Modify the length of parameter 6.2.1 AT+SIDET Extend parameter 6.2.4 AT+CMIC Extend parameter , add default value description in note 6.2.5 AT+CALA Modify indicate expired alarm 6.2.13 AT+CLDTMF Extend parameter and add parameter , add the funcion that local DTMF tone can be played in call. 6.2.56 AT+CMICBIAS Add note description 6.2.58 AT+SJDR Modify format error 6.2.63 AT+SD2PCM Add AT command 6.2.64 AT+SKPD Add AT command SIM800 Series_AT Command Manual_V1.10 17 2016-02-01 Smart Machine Smart Decision V1.04 2014-06-10 6.2.65 AT+SIMTONEX Add AT command 6.2.66 AT+CROAMING Add AT command 6.2.67 AT+CNETSCAN Add AT command 8.2.23 AT+CIPCCFG Modify wait time’s interval 12.2.24 AT+FTPGETTOFS Add AT command 16.2.1 AT+DDET Modify description about parameter, add parameter 17.2.1 AT+CREC Modify and AT+CREC=8 description,add read length limit and AMR support description in note 18.2.3 AT+CTTSRING Add command AT+CTTSRING 20.6 Audio command Add AT+CLDTMF example 20.11 PING Commands Add other device ping to the modem 21.6 AT+CHFA Modify description 21.7 AT+CMIC Add difference desription 21.8 AT+SIDET Add difference desription AT+FCLASS AT+FMI AT+FMM AT+FMR Delete 1.1 Scope of the document Add SIM800W16, SIM840W16, SIM800-WB64, SIM808 2.2.27 ATZ Modify note 2.2.30 AT&F Modify note 2.2.32 AT&W Modify note 3.2.46 AT+CALS Modify descripton 4.2.8 AT+CNMI Add the " [alpha>], " string 6.2.1 AT+SIDET Modify note 6.2.4 AT+CMIC Modify note 6.2.8 AT+CSNS Modify parameter save mode 6.2.13 AT+CLDTMF Modify note 6.2.17 AT+CBAND Modify note 6.2.18 AT+CHF Modify note 6.2.19 AT+CHFA Modify note 6.2.40 AT+SGPIO Modify note 6.2.41 AT+SPWM Extend the scope of parameter to "0-100000" 6.2.58 AT+SJDR Modify note 6.2.59 AT+CPCMCFG Modify note SIM800 Series_AT Command Manual_V1.10 18 2016-02-01 Smart Machine Smart Decision V1.05 2014-07-31 6.2.60 AT+CPCMSYNC Modify note 6.2.62 AT+CANT Modify note 6.2.63 AT+SD2PCM Modify note 6.2.64 AT+SKPD Modify note 6.2.66 AT+CROAMING Modify AT+CROAMING command’s format 6.2.67 AT+CNETSCAN Modify AT+CNETSCAN command’s function and note 6.2.68 AT+CMNRP Add AT command 8.2.2 AT+CIPSTART Modify max response time 8.2.30 AT+CIPTKA Add AT command 10.2.4 AT+CIPBEIPING Add AT command 12.2.2 AT+FTPMODE Modify test and write command 12.2.14 AT+FTPGET Modify note, Add "Manual quit" to 12.2.23 AT+FTPLIST Modify note 12.2.24 AT+FTPGETTOFS Add read command 12.2.25 AT+FTPPUTFRMFS Add AT command 12.2.26 AT+FTPEXTGET Add AT command 12.2.27 AT+FTPFILEPUT Add AT command 12.2.28 AT+FTPQUIT Add AT command 13.2.1 AT+CIPGSMLOC Modify max response time 16.2.1 AT+DDET Modify response value of test command 17.2.1 AT+CREC Modify parameter description and note 18 Modify note 19.3 URC Add URC of AT+CGREG,AT+CALA,AT+CIURC,AT+CNMI 20.2 SIM commands Modify response of AT+CPBS=? 21 Modify ATC difference 21.4 AT+CHFA Add PCM channel SIM800-WB64 All Change SIM800-WB64 to SIM800M64 6.2.21 AT+CENG Add format description of part parameters 6.2.40 AT+SGPIO Extend the scope of parameter to "1-7" 6.2.69 AT+CEGPRS Add AT command 12.2.24 AT+FTPGETTOFS Modify description of 14.2.14 AT+POP3IN Add description of value 69 14.2.22 AT+POP3OUT Add description of
value 69 21.2 AT+CMIC Modify SIM800 Series_AT Command Manual_V1.10 19 in SIM800 2016-02-01 and Smart Machine Smart Decision 1.06 1.07 1.08 1.09 2014-10-28 2014-12-19 2015-05-12 2015-08-03 21.5 AT+SGPIO Modify difference 21.9 AT+CADC Add difference 21.10 AT+CSCLK Add difference 21.13 Add GPIO difference 6.2.52 AT+CWHITELIST Extend the scope of parameter
to "0-3" 6.2.70 AT+CGPIO Add AT command 6.2.71 AT+CMEDPLAY Add AT command 6.2.72 AT+CMEDIAVOL Add AT command 8.2.14 AT+CDNSGIP Add error code 12.2 Modify max response time 17.2.1 AT+CREC Modify note 19.3 Modify note 1.1 Scope of the document Add SIM800C 2.2.16 ATS0 Modify note 6.2.20 AT+CSCLK Modify note 6.2.73 AT+SNDLEVEL Add AT command 21 Add differences of SIM800C 6.2.55 AT+CSGS Extend the scope of parameter to "0-2" 6.2.74 AT+ECHARGE Add AT command 6.2.75 AT+SIMTIMER Add AT command 6.2.76 AT+SPE Add AT command 17.2.1 AT+CREC Modify note 19.1 Change CME error codes from 810~824 to 600~614 21.13 Add AT+ECHARGE,AT+SIMTIMER,AT+SPE 1.1 Scope of the document Add SIM800A, SIM800F, SIM800C-DS 6.2.21 AT+CENG Extend the scope of parameter to "0-4" and modify note 6.2.65 AT+SIMTONEX Modify note 6.2.70 AT+CGPIO Modify response value of test command 6.2.71 AT+CMEDPLAY Modify note 6.2.77 AT+CCONCINDEX Add AT command 6.2.78 AT+SDMODE Add AT command 6.2.79 AT+SRSPT Add AT command 11.2.9 AT+HTTPHEAD Add AT command 15.2.6 AT+CMMSDOWN Modify parameter 17.2.1 AT+CREC Modify note 19.3 Delete URC of "AT+CENG" when =3 SIM800 Series_AT Command Manual_V1.10 20 2016-02-01 Smart Machine Smart Decision 1.10 2016-05-18 20.2 SIM commands Add examples of "AT+CENG" 21.11 AT+CMMSDOWN Add difference of "AT+CMMSDOWN" 21.12 AT+CFGRI Add difference of "AT+CFGRI" 21 Add differences of SIM800A,SIM800F and SIM800C-DS 1.1 Scope of the document Add SIM868 3.2.17 AT+CLCK Modify note 3.2.52 AT+CBC Modify note 4.2.15 AT+CSMP Modify note 6.2.11 AT+CFGRI Modify note 6.2.12 AT+CLTS Modify parameter and note 6.2.21 AT+CENG Modify note 6.2.24 AT+CMTE Modify range of 6.2.58 AT+SJDR Modify write command and note 6.2.71 AT+CMEDPLAY Modify note 6.2.80 AT+CELLIST Add AT command 6.2.81 AT+CLIST Add AT command 6.2.82 AT+CBATCHK Add AT command 7.2.1 AT+CGATT Modify max response time 8.2.6 AT+CIPCLOSE Modify note 8.2.9 AT+CSTT Modify note of parameters 8.2.11 AT+CIFSR Modify note 11.2.5 AT+HTTPACTION Extend the scope of parameter to "0-3" 14.2.4 AT+SMTPAUTH Modify response of test command 15.2.17 AT+CMMSREAD Add description of 16.2.1 AT+DDET Modify value of 18.2.1 AT+CTTS Modify description of 20.2 Add examples of AT+CELLIST 21.7 AT+CREC Modify note 21.13 AT+CLCK Add difference 21.4 Add difference SIM800 Series_AT Command Manual_V1.10 21 2016-02-01 Smart Machine Smart Decision 1 Introduction 1.1 Scope of the document This document presents the AT Command Set for SIMCom SIM800 Series, including SIM800V, SIM840V, SIM800W, SIM840W, SIM800W16, SIM840W16, SIM800L, SIM800H, SIM800, SIM800M64, SIM800G, SIM808, SIM800C, SIM800A, SIM800F, SIM800C-DS and SIM868. 1.2 Related documents You can visit the SIMCom Website using the following link: http://www.sim.com 1.3 Conventions and abbreviations In this document, the GSM engines are referred to as following term: ME (Mobile Equipment); MS (Mobile Station); TA (Terminal Adapter); DCE (Data Communication Equipment) or facsimile DCE (FAX modem, FAX board); In application, controlling device controls the GSM engine by sending AT Command via its serial interface. The controlling device at the other end of the serial line is referred to as following term: TE (Terminal Equipment); DTE (Data Terminal Equipment) or plainly "the application" which is running on an embedded system; 1.4 AT Command syntax The "AT" or "at" or “aT” or “At”prefix must be set at the beginning of each Command line. To terminate a Command line enter . Commands are usually followed by a response that includes. " " Throughout this document, only the responses are presented, are omitted intentionally. The AT Command set implemented by SIM800 Series is a combination of 3GPP TS 27.005, 3GPP TS 27.007 and ITU-T recommendation V.25ter and the AT commands developed by SIMCom. Note: A HEX string such as "00 49 49 49 49 FF FF FF FF" will be sent out through serial port at the baud rate of 115200 immediately after SIM800 Series is powered on. The string shall be ignored since it is used for SIM800 Series_AT Command Manual_V1.10 22 2016-02-01 Smart Machine Smart Decision synchronization with PC tool. Only enter AT Command through serial port after SIM800 Series is powered on and Unsolicited Result Code "RDY" is received from serial port. If auto-bauding is enabled, the Unsolicited Result Codes "RDY" and so on are not indicated when you start up the ME, and the "AT" prefix, or "at" prefix must be set at the beginning of each command line. All these AT commands can be split into three categories syntactically: "basic", "S parameter", and "extended". These are as follows: 1.4.1 Basic syntax These AT commands have the format of "AT ", or "AT& ", where " "is the Command, and " "is/are the argument(s) for that Command. An example of this is "ATE ", which tells the DCE whether received characters should be echoed back to the DTE according to the value of " ". " " is optional and a default will be used if missing. 1.4.2 S Parameter syntax These AT commands have the format of "ATS = ", where " " is the index of the S register to set, and " "is the value to assign to it. " " is optional; if it is missing, then a default value is assigned. 1.4.3 Extended Syntax These commands can operate in several modes, as in the following table: Table 1: Types of AT commands and responses Test Command AT+ =? The mobile equipment returns the list of parameters and value ranges set with the corresponding Write Command or by internal processes. Read Command AT+ ? This command returns the currently set value of the parameter or parameters. Write Command AT+ =<…> This command sets the user-definable parameter values. Execution Command AT+ The execution command reads non-variable parameters affected by internal processes in the GSM engine. 1.4.4 Combining AT commands on the same Command line You can enter several AT commands on the same line. In this case, you do not need to type the "AT" or "at" prefix before every command. Instead, you only need type "AT" or "at" the beginning of the command line. Please note to use a semicolon as the command delimiter after SIM800 Series_AT Command Manual_V1.10 23 2016-02-01 Smart Machine Smart Decision an extended command; in basic syntax or S parameter syntax, the semicolon need not enter, for example: ATE1Q0S0=1S3=13V1X4;+IFC=0,0;+IPR=115200;&W. The Command line buffer can accept a maximum of 556 characters (counted from the first command without “AT” or “at” prefix). If the characters entered exceeded this number then none of the Command will executed and TA will return "ERROR". 1.4.5 Entering successive AT commands on separate lines When you need to enter a series of AT commands on separate lines, please Note that you need to wait the final response (for example OK, CME error, CMS error) of last AT Command you entered before you enter the next AT Command. 1.5 Supported character sets The SIM800 Series AT Command interface defaults to the IRA character set. The SIM800 Series supports the following character sets: GSM format UCS2 HEX IRA PCCP PCDN 8859-1 The character set can be set and interrogated using the "AT+CSCS" Command (3GPP TS 27.007). The character set is defined in GSM specification 3GPP TS 27.005. The character set affects transmission and reception of SMS and SMS Cell Broadcast messages, the entry and display of phone book entries text field and SIM Application Toolkit alpha strings. 1.6 Flow control Flow control is very important for correct communication between the GSM engine and DTE. For in the case such as a data or fax call, the sending device is transferring data faster than the receiving side is ready to accept. When the receiving buffer reaches its capacity, the receiving device should be capable to cause the sending device to pause until it catches up. There are basically two approaches to achieve data flow control: software flow control and hardware flow control. SIM800 Series support both two kinds of flow control. In Multiplex mode, it is recommended to use the hardware flow control. 1.6.1 Software flow control (XON/XOFF flow control) Software flow control sends different characters to stop (XOFF, decimal 19) and resume (XON, decimal 17) data flow. It is quite useful in some applications that only use three wires on the serial interface. SIM800 Series_AT Command Manual_V1.10 24 2016-02-01 Smart Machine Smart Decision The default flow control approach of SIM800 Series is hardware flow control (RTS/CTS flow control), to enable software flow control in the DTE interface and within GSM engine, type the following AT Command: AT+IFC=1, 1 This setting is stored volatile, for use after restart, AT+IFC=1, 1 should be stored to the user profile with AT&W. NOTE: The AT commands listed in the table of AT&W chapter should be stored to user profile with AT&W for use after restart. Most other AT commands in V.25, 3GPP TS 27.005, 3GPP TS 27.007,GPRS will store parameters automatically and can be used after module restart. Ensure that any communications software package (e.g. Hyper terminal) uses software flow control. NOTE: Software Flow control should not be used for data calls where binary data will be transmitted or received (e.g. TCP/IP) as the DTE interface may interpret binary data as flow control characters. 1.6.2 Hardware flow control (RTS/CTS flow control) Hardware flow control achieves the data flow control by controlling the RTS/CTS line. When the data transfer should be suspended, the CTS line is set inactive until the transfer from the receiving buffer has completed. When the receiving buffer is ok to receive more data, CTS goes active once again. To achieve hardware flow control, ensure that the RTS/CTS lines are present on your application platform. 1.7 Definitions 1.7.1 Parameter Saving Mode For the purposes of the present document, the following syntactical definitions apply: l NO_SAVE: The parameter of the current AT command will be lost if module is rebooted or current AT command doesn't have parameter. l AUTO_SAVE: The parameter of the current AT command will be kept in NVRAM automatically, and it won't be lost if module is rebooted. l AT&W_SAVE: The parameter of the current AT command will be kept in NVRAM by sending the command of "AT&W". SIM800 Series_AT Command Manual_V1.10 25 2016-02-01 Smart Machine Smart Decision 1.7.2 Max Response Time Max response time is estimated maximum time to get response, the unit is seconds. "-" means this AT command doesn’t care the response time. SIM800 Series_AT Command Manual_V1.10 26 2016-02-01 Smart Machine Smart Decision 2 AT Commands According to V.25TER These AT Commands are designed according to the ITU-T (International Telecommunication Union, Telecommunication sector) V.25ter document. 2.1 Overview of AT Commands According to V.25TER Command A/ Description Re-issues the last command given ATA Answer an incoming call ATD Mobile originated call to dial a number ATD> Originate call to phone number in current memory ATD> Originate call to phone number in memory which corresponds to field ATDL Redial last telephone number used ATE Set command echo mode ATH Disconnect existing connection ATI Display product identification information ATL Set monitor speaker loudness ATM Set monitor speaker mode +++ Switch from data mode or ppp online mode to command mode ATO Switch from command mode to data mode ATP Select pulse dialling ATQ Set result code presentation mode ATS0 Set number of rings before automatically answering the call ATS3 Set command line termination character ATS4 Set response formatting character ATS5 Set command line editing character ATS6 Pause before blind dialling ATS7 Set number of seconds to wait for connection completion ATS8 Set number of seconds to wait for comma dial modifier encountered in dial string of D command ATS10 Set disconnect delay after indicating the absence of data carrier ATT Select tone dialing ATV TA response format ATX Set connect result code format and monitor call progress ATZ Reset default configuration AT&C Set DCD function mode AT&D Set DTR function mode SIM800 Series_AT Command Manual_V1.10 27 2016-02-01 Smart Machine Smart Decision AT&F Factory defined configuration AT&V Display current configuration AT&W Store active profile AT+GCAP Request complete TA capabilities list AT+GMI Request manufacturer identification AT+GMM Request TA model identification AT+GMR Request TA revision identification of software release AT+GOI Request global object identification AT+GSN Request TA serial number identification (IMEI) AT+ICF Set TE-TA control character framing AT+IFC Set TE-TA local data flow control AT+IPR Set TE-TA fixed local rate AT+HVOIC Disconnect voice call only 2.2 Detailed Description of AT Commands According to V.25TER 2.2.1 A/ Re-issues the Last Command Given A/ Re-issues the Last Command Given Execution Command A/ Response Re-issues the previous Command Reference V.25ter Note 2.2.2 ATA Answer an Incoming Call ATA Answer an Incoming Call Execution Command ATA Response TA sends off-hook to the remote station. Note1: Any additional commands on the same Command line are ignored. Note2: This command may be aborted generally by receiving a character during execution. The aborting is not possible during some states of connection establishment such as handshaking. Response in case of data call, if successfully connected CONNECT TA switches to data mode. Note: output only if ATX parameter setting with the >0 When TA returns to Command mode after call release OK Response in case of voice call, if successfully connected SIM800 Series_AT Command Manual_V1.10 28 2016-02-01 Smart Machine Smart Decision OK Response if no connection NO CARRIER Parameter Saving NO_SAVE Mode Max Time Response 20s(voice call) Timeout set with ATS7 (data call) Reference V.25ter 2.2.3 ATD ATD Note See also ATX Mobile Originated Call to Dial A Number Mobile Originated Call to Dial A Number Execution Command ATD [ If no dial tone and (parameter setting ATX2 or ATX4) NO DIALTONE If busy and (parameter setting ATX3 or ATX4) BUSY If a connection cannot be established NO CARRIER If the remote station does not answer NO ANSWER If connection successful and non-voice call. CONNECT TA switches to data mode. Note: output only if ATX parameter setting with the >0 When TA returns to command mode after call release OK SIM800 Series_AT Command Manual_V1.10 29 2016-02-01 Smart Machine Smart Decision If connection successful and voice call OK Parameters String of dialing digits and optionally V.25ter modifiers dialing digits: 0-9, * , #, +, A, B, C Following V.25ter modifiers are ignored: ,(comma), T, P, !, W, @ Emergency call: Standardized emergency number 112 (no SIM needed) String of GSM modifiers: I Actives CLIR (Disables presentation of own number to called party) i Deactivates CLIR (Enable presentation of own number to called party) G Activates Closed User Group invocation for this call only g Deactivates Closed User Group invocation for this call only <;> Only required to set up voice call , return to Command state Parameter Saving NO_SAVE Mode Max Time Response 20s(voice call) Timeout set with ATS7 (data call) Reference V.25ter Note Parameter "I" and "i" only if no *# code is within the dial string is default for last number that can be dialed by ATDL *# codes sent with ATD are treated as voice calls. Therefore, the Command must be terminated with a semicolon ";" See ATX Command for setting result code and call monitoring parameters. Responses returned after dialing with ATD For voice call two different responses mode can be determined. TA returns "OK" immediately either after dialing was completed or after the call is established. The setting is controlled by AT+COLP. Factory default is AT+COLP=0, this cause the TA returns "OK" immediately after dialing was completed, otherwise TA will returns "OK", "BUSY", "NO DIAL TONE", "NO CARRIER". Using ATD during an active voice call: When a user originates a second voice call while there is already an active voice call, the first call will be automatically put on hold. SIM800 Series_AT Command Manual_V1.10 30 2016-02-01 Smart Machine Smart Decision The current states of all calls can be easily checked at any time by using the AT+CLCC Command. 2.2.4 ATD> Originate Call to Phone Number in Current Memory ATD> Originate Call to Phone Number in Current Memory Execution Command ATD> [ ][ ][;] Response This command can be used to dial a phone number from current phonebook memory. Note: This command may be aborted generally by receiving an ATH command or a character during execution. The aborting is not possible during some states of connection establishment such as handshaking. If error is related to ME functionality +CME ERROR: If no dial tone and (parameter setting ATX2 or ATX4) NO DIALTONE If busy and (parameter setting ATX3 or ATX4) BUSY If a connection cannot be established NO CARRIER If the remote station does not answer NO ANSWER If connection successful and non-voice call. CONNECT TA switches to data mode. Note: output only if ATX parameter setting with the >0 When TA returns to command mode after call release OK If successfully connected and voice call OK Parameters Integer type memory location should be in the range of locations available in the memory used String of GSM modifiers: SIM800 Series_AT Command Manual_V1.10 31 2016-02-01 Smart Machine Smart Decision I Override the CLIR supplementary service subscription default value for this call Invocation (restrict CLI presentation) i Override the CLIR supplementary service subscription default value for this call Suppression (allow CLI presentation) <;> G Control the CUG supplementary service information for this call CUG Not supported g Control the CUG supplementary service information for this call CUG Not supported Only required to set up voice call , return to command state Parameter Saving NO_SAVE Mode Max Time Response - Reference V.25ter Note Parameter "I" and "i" only if no *# code is within the dial string *# codes sent with ATD are treated as voice calls. Therefore, the command must be terminated with a semicolon ";" See ATX Command for setting result code and call monitoring parameters. 2.2.5 ATD> Originate Call to Phone Number in Memory Which Corresponds to Field ATD> Originate Call to Phone Number in Memory Which Corresponds to Field Execution Command ATD> [ ][ ][;] Response This command make the TA attempts to set up an outgoing call to stored number. All available memories are searched for the entry . Note: This command may be aborted generally by receiving an ATH Command or a character during execution. The aborting is not possible during some states of connection establishment such as handshaking. If error is related to ME functionality +CME ERROR: If no dial tone and (parameter setting ATX2 or ATX4) NO DIALTONE If busy and (parameter setting ATX3 or ATX4) SIM800 Series_AT Command Manual_V1.10 32 2016-02-01 Smart Machine Smart Decision BUSY If a connection cannot be established NO CARRIER If the remote station does not answer NO ANSWER If connection successful and non-voice call. CONNECT TA switches to data mode. Note: output only if ATX parameter setting with the >0 When TA returns to command mode after call release OK If successfully connected and voice call OK Parameters String type (string should be included in quotation marks) value ("x"), which should equal to an alphanumeric field in at least one phone book entry in the searched memories. formatted as current TE character set specified by +CSCS. String of GSM modifiers: I Actives CLIR (Disables presentation of own number to called party) i Deactivates CLIR (Enable presentation of own number to called party) G Activates Closed User Group invocation for this call only g Deactivates Closed User Group invocation for this call only <;> Only required to set up voice call, return to Command state Parameter Saving NO_SAVE Mode Max Time Response - Reference V.25ter Note Parameter "I" and "i" only if no "*#" code is within the dial string *# codes sent with ATD are treated as voice calls. Therefore, the Command must be terminated with a semicolon ";" See ATX Command for setting result code and call monitoring parameters. 2.2.6 ATDL Redial Last Telephone Number Used ATDL Redial Last Telephone Number Used SIM800 Series_AT Command Manual_V1.10 33 2016-02-01 Smart Machine Smart Decision Execution Command ATDL Response This command redials the last voice and data call number used. Note: This command may be aborted generally by receiving an ATH Command or a character during execution. The aborting is not possible during some states of connection establishment such as handshaking. If error is related to ME functionality +CME ERROR: If no dial tone and (parameter setting ATX2 or ATX4) NO DIALTONE If busy and (parameter setting ATX3 or ATX4) BUSY If a connection cannot be established NO CARRIER If the remote station does not answer NO ANSWER If connection successful and non-voice call. CONNECT TA switches to data mode. Note: output only if ATX parameter setting with the >0 When TA returns to Command mode after call release OK If successfully connected and voice call OK Parameter Saving NO_SAVE Mode Max Time Response - Reference V.25ter 2.2.7 ATE ATE Note See ATX Command for setting result code and call monitoring parameters. Return the numbers and symbols which ATD supports if there is no last dialing context. Set Command Echo Mode Set Command Echo Mode SIM800 Series_AT Command Manual_V1.10 34 2016-02-01 Smart Machine Smart Decision Execution Command ATE Response This setting determines whether or not the TA echoes characters received from TE during Command state. OK Parameters 0 Echo mode off 1 Echo mode on Parameter Saving AT&W_SAVE Mode Max Time Response - Reference V.25ter Note 2.2.8 ATH Disconnect Existing Connection ATH Disconnect Existing Connection Execution Command ATH Response Disconnect existing call by local TE from Command line and terminate call OK Note: OK is issued after circuit 109(DCD) is turned off, if it was previously on. Parameter Saving NO_SAVE Mode Max Time Response 20s Reference V.25ter Note 2.2.9 ATI Display Product Identification Information ATI Display Product Identification Information Execution Command ATI Response TA issues product information text Example: SIM800 R11.08 OK Parameter Saving NO_SAVE Mode Max Response - SIM800 Series_AT Command Manual_V1.10 35 2016-02-01 Smart Machine Smart Decision Time Reference V.25ter Note 2.2.10 ATL Set Monitor speaker loudness ATL Set Monitor speaker loudness Execution Command ATL Response OK Parameters 0..9 Volume Parameter Saving NO_SAVE Mode Max Time Response - Reference V.25ter Note No effect in GSM 2.2.11 ATM Set Monitor Speaker Mode ATM Set Monitor Speaker Mode Execution Command ATM Response OK Parameters 0..9 Mode Parameter Saving NO_SAVE Mode Max Time Response - Reference V.25ter Note No effect in GSM 2.2.12 +++ Switch from Data Mode or PPP Online Mode to Command Mode +++ Switch from Data Mode or PPP Online Mode to Command Mode Execution Command +++ Response The +++ character sequence causes the TA to cancel the data flow over the AT interface and switch to Command mode. This allows you to enter AT Command while maintaining the data connection to the remote server. OK To prevent the +++ escape sequence from being misinterpreted as data, it should comply to following sequence: No characters entered for T1 time (1 second) SIM800 Series_AT Command Manual_V1.10 36 2016-02-01 Smart Machine Smart Decision "+++" characters entered with no characters in between (1 second) No characters entered for T1 timer (1 second) Switch to Command mode, otherwise go to step 1. Parameter Saving NO_SAVE Mode Max Time Response - Reference V.25ter Note To return from Command mode back to data mode: Enter ATO. 2.2.13 ATO Switch from Command Mode to Data Mode ATO Switch from Command Mode to Data Mode Execution Command ATO[n] Response TA resumes the connection and switches back from command mode to data mode. CONNECT If connection is not successfully resumed ERROR else TA returns to data mode from command mode CONNECT Note: only if parameter setting ATX>0 Parameter 0 Switch from command mode to data mode. Parameter Saving NO_SAVE Mode Max Time Response - Reference V.25ter Note 2.2.14 ATP Select Pulse Dialling ATP Select Pulse Dialling Execution Command ATP Response OK Parameter Saving NO_SAVE Mode Max Time Response - SIM800 Series_AT Command Manual_V1.10 37 2016-02-01 Smart Machine Smart Decision Reference V.25ter Note No effect in GSM 2.2.15 ATQ Set Result Code Presentation Mode ATQ Set Result Code Presentation Mode Execution Command ATQ Response This parameter setting determines whether or not the TA transmits any result code to the TE. Information text transmitted in response is not affected by this setting. If =0: OK If =1: (none) Parameters 0 TA transmits result code 1 Result codes are suppressed and not transmitted Parameter Saving AT&W_SAVE Mode Max Time Response - Reference V.25ter Note 2.2.16 ATS0 Set Number of Rings before Automatically Answering the Call ATS0 Set Number of Rings before Automatically Answering the Call Read Command ATS0? Response OK Parameters See Write Command Write Command ATS0= Response This parameter setting determines the number of rings before auto-answer. OK ERROR Parameters 0 Automatic answering is disable. 1-255 Number of rings the modem will wait for before answering the phone if a ring is detected. Parameter Saving AT&W_SAVE Mode SIM800 Series_AT Command Manual_V1.10 38 2016-02-01 Smart Machine Smart Decision Max Time Response - Reference V.25ter Note If is set too high, the calling party may hang up before the call can be answered automatically. If using cmux port, ATH and AT+CHUP can hang up the call (automatically answering) only in the CMUX channel 0. If using dual-physical serial port, ATH and AT+CHUP can hang up the call (automatically answering) only in UART1. 2.2.17 ATS3 Set Command Line Termination Character ATS3 Set Command Line Termination Character Read Command ATS3? Response OK Parameters See Write Command Write Command ATS3= Response This parameter setting determines the character recognized by TA to terminate an incoming command line. The TA also returns this character in output. OK ERROR Parameters 13 Command line termination character Parameter Saving AT&W_SAVE Mode Max Time Response - Reference V.25ter Note Default 13 = CR. It only supports default value. 2.2.18 ATS4 Set Response Formatting Character ATS4 Set Response Formatting Character Read Command ATS4? Response OK Parameters See Write Command SIM800 Series_AT Command Manual_V1.10 39 2016-02-01 Smart Machine Smart Decision Write Command ATS4= Response This parameter setting determines the character generated by the TA for result code and information text. OK ERROR Parameters 10 Response formatting character Parameter Saving AT&W_SAVE Mode Max Time Response - Reference V.25ter Note Default 10 = LF. It only supports default value. 2.2.19 ATS5 Set Command Line Editing Character ATS5 Set Command Line Editing Character Read Command ATS5? Response OK Parameters See Write Command Write Command ATS5= Response This parameter setting determines the character recognized by TA as a request to delete from the command line the immediately preceding character. OK ERROR Parameters 0-8-127 Response formatting character Parameter Saving AT&W_SAVE Mode Max Time Response - Reference V.25ter Note Default 8 = Backspace. SIM800 Series_AT Command Manual_V1.10 40 2016-02-01 Smart Machine Smart Decision 2.2.20 ATS6 Pause Before Blind Dialling ATS6 Pause Before Blind Dialling Read Command ATS6? Response OK Write Command ATS6= Response OK ERROR Parameters 0..999 Time Parameter Saving AT&W_SAVE Mode Max Time Response - Reference V.25ter Note No effect in GSM 2.2.21 ATS7 Set Number of Seconds to Wait for Connection Completion ATS7 Set Number of Seconds to Wait for Connection Completion Read Command ATS7? Response OK Parameters See Write Command Write Command ATS7= Response This parameter setting determines the amount of time to wait for the connection completion in case of answering or originating a call. OK ERROR Parameters 1-60-255 Number of seconds to wait for connection completion Parameter Saving AT&W_SAVE Mode Max Time Response - Reference V.25ter Note If called party has specified a high value for ATS0= , call setup may fail. The correlation between ATS7 and ATS0 is important SIM800 Series_AT Command Manual_V1.10 41 2016-02-01 Smart Machine Smart Decision Example: Call may fail if ATS7=30 and ATS0=20. ATS7 is only applicable to data call. 2.2.22 ATS8 Set Number of Seconds to Wait for Comma Dial Modifier Encountered in Dial String of D Command ATS8 Set Number of Seconds to Wait for Comma Dial Modifier Encountered in Dial String of D Command Read Command ATS8? Response OK Parameters See Write Command Write Command ATS8= Response OK ERROR Parameters 0-255 The value of this register determines how long the modem should pause when it sees a comma in the dialing string. Parameter Saving AT&W_SAVE Mode Max Time Response - Reference V.25ter Note No effect in GSM 2.2.23 ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier Read Command ATS10? Response OK Parameters See Write Command Write Command ATS10= Response This parameter setting determines the amount of time that the TA will remain connected in absence of data carrier. If the data carrier is once more detected before disconnecting, the TA remains connected. OK ERROR SIM800 Series_AT Command Manual_V1.10 42 2016-02-01 Smart Machine Smart Decision Parameters 1-15-254 Number of tenths seconds of delay Parameter Saving AT&W_SAVE Mode Max Time Response - Reference V.25ter Note 2.2.24 ATT Select Tone Dialing ATT Select Tone Dialing Execution Command ATT Response OK Parameter Saving AUTO_SAVE Mode Max Time Response - Reference V.25ter Note 2.2.25 ATV TA Response Format ATV TA Response Format Execution Command ATV Response This parameter setting determines the contents of the header and trailer transmitted with result codes and information responses. When =0 0 When =1 OK Parameters 0 Information response: Short result code format: 1 Information response: Long result code format: The result codes, their numeric equivalents and brief descriptions of the use of each are listed in the following table. Parameter Saving AT&W_SAVE Mode SIM800 Series_AT Command Manual_V1.10 43 2016-02-01 Smart Machine Smart Decision Max Time Response - Reference V.25ter Note ATV1 ATV0 Description OK 0 Acknowledges execution of a Command CONNECT 1 A connection has been established; the DCE is moving from Command state to online data state RING 2 The DCE has detected an incoming call signal from network NO CARRIER 3 The connection has been terminated or the attempt to establish a connection failed ERROR 4 Command not recognized, Command line maximum length exceeded, parameter value invalid, or other problem with processing the Command line NO DIALTONE 6 No dial tone detected BUSY 7 Engaged (busy) signal detected NO ANSWER 8 "@" (Wait for Quiet Answer) dial modifier was used, but remote ringing followed by five seconds of silence was not detected before expiration of the connection timer (S7) PROCEEDING 9 An AT command is being processed CONNECT Manufacturerspecific Same as CONNECT, but includes manufacturer-specific text that may specify DTE speed, line speed, error control, data compression, or other status 2.2.26 ATX Set CONNECT Result Code Format and Monitor Call Progress ATX Set CONNECT Result Code Format and Monitor Call Progress Execution Command ATX Response This parameter setting determines whether or not the TA detected the presence of dial tone and busy signal and whether or not TA transmits particular result codes. OK ERROR Parameters 0 CONNECT result code only returned, dial tone and busy detection are both disabled. 1 CONNECT result code only returned, dial tone and busy detection are both disabled. 2 CONNECT result code returned, dial tone SIM800 Series_AT Command Manual_V1.10 44 2016-02-01 Smart Machine Smart Decision detection is enabled, busy detection is disabled. 3 CONNECT result code returned, dial tone detection is disabled, busy detection is enabled. 4 CONNECT result code returned, dial tone and busy detection are both enabled. Parameter Saving AT&W_SAVE Mode Max Time Response - Reference V.25ter Note 2.2.27 ATZ Reset Default Configuration ATZ Reset Default Configuration Execution Command ATZ[ ] Response TA sets all current parameters to the user defined profile. OK ERROR Parameters 0 Restore profile 0 Parameter Saving NO_SAVE Mode Max Time Response - Reference V.25ter Note Parameter impacted by Z command: refer to AT&W NOTE: Parameters related to uart operation, like csclk, ipr, icf, ifc and cmnrp, will not be reset to default configuration. 2.2.28 AT&C Set DCD Function Mode AT&C Set DCD Function Mode Execution Command AT&C Response This parameter determines how the state of circuit 109 (DCD) relates to the detection of received line signal from the distant end. OK ERROR Parameters 0 DCD line is always ON SIM800 Series_AT Command Manual_V1.10 45 2016-02-01 Smart Machine Smart Decision 1 DCD line is ON only in the presence of data carrier Parameter Saving AT&W_SAVE Mode Max Time Response - Reference V.25ter Note 2.2.29 AT&D Set DTR Function Mode AT&D Set DTR Function Mode Execution Command AT&D[ ] Response This parameter determines how the TA responds when circuit 108/2 (DTR) is changed from the ON to the OFF condition during data mode. OK ERROR Parameters 0 TA ignores status on DTR. 1 ON->OFF on DTR: Change to Command mode with remaining the connected call. 2 ON->OFF on DTR: Disconnect call, change to Command mode. During state DTR = OFF is auto-answer off. Parameter Saving AT&W_SAVE Mode Max Time Response - Reference V.25ter Note 2.2.30 AT&F Factory Defined Configuration AT&F Factory Defined Configuration Execution Command AT&F[ ] Response TA sets all current parameters to the manufacturer defined profile. OK Parameters 0 Set all TA parameters to manufacturer defaults. Parameter Saving NO_SAVE Mode Max Time Response - Reference Note SIM800 Series_AT Command Manual_V1.10 46 2016-02-01 Smart Machine Smart Decision V.25ter Parameter impacted by &F command: refer to AT&W NOTE: Parameters related to uart operation, like csclk, ipr, icf, ifc and cmnrp, will not be reset to default configuration. 2.2.31 AT&V Display Current Configuration AT&V Display Current Configuration Execution Command AT&V[ ] Response TA returns the current parameter setting. OK ERROR Parameters 0 Responses in numeric format Parameter Saving NO_SAVE Mode Max Time Response - Reference V.25ter Note 2.2.32 AT&W Store Active Profile AT&W Store Active Profile Execution Command AT&W[ ] Response TA stores the current parameter setting in the user defined profile. OK ERROR Parameters 0 Store the current configuration in profile 0 Parameter Saving NO_SAVE Mode Max Time Response - Reference V.25ter Note The user defined profile is stored in non volatile memory. Parameter stored by &W Command Parameter name SIM800 Series_AT Command Manual_V1.10 Displayedby &V 47 2016-02-01 Smart Machine Smart Decision ATS0 Y ATS3 Y ATS4 Y ATS5 Y ATS6 Y ATS7