ZR12 Service Manual SM_ZR12_EN_A SM EN A

User Manual: SM_ZR12_EN_A

Open the PDF directly: View PDF PDF.
Page Count: 29

DownloadZR12 Service Manual SM_ZR12_EN_A SM EN A
Open PDF In BrowserView PDF
JEM Smoke Machine Training Program
INDEX
An Introduction To Smoke Technology:
Smoke Machine Markets
Smoke Machine Principles
CE Marking
Searching for information on the NET
Which fluid can I use with my machine?
What can my machine do?
Specifications

3
3
4
5
6
6
7

Service of machines:
Tools and optional extras
Machine Overview
Opening The Machine
Inside The Machine

9
10
11
11

How To…
How To Change A Heat Exchanger
How To Change A Pump
How To Change A PCB
Control PCB
Calibration

12
13
14
14
15

Spare Parts Lists:
Spare Parts 240V
Spare Parts 110V

16
17

Appendix:
Fuse Ratings
PCB Schematics

17
18

2

AN INTRODUCTION TO SMOKE TECHNOLOGY
Smoke Machine Markets
Jem / Martin smoke machines are categorised into 2 ranges: The Professional and the Club / DJ range.
If a product is branded as a “Martin” product this is aimed at the Club / DJ market.
All products branded as a “JEM” product are classed as Professional and are aimed at the higher end touring /
installation market.
All JEM / Martin Smoke products can be used across both of the different markets without any compromise of
performance or features.

Smoke machine principles:
All JEM / Martin conventional smoke machines utilise the same technology:
In Brief:
When the run button on the remote is pressed, smoke fluid is pumped from a removable container
situated within the machine via the flexible fluid pipe into an oscillating piston pump.
The fluid passes through the pump and enters the heat exchanger were the fluid is vaporised and
exits as thick, white smoke.

The heat exchanger is comprised of a heating element and a coil of copper or steel tubing between 3 and 6
metres in length. This is cast into a mass of aluminium.
The heat exchanger is heated via the heating element.
This is controlled by a J Type thermocouple fitted to the heat exchanger.
The temperature is determined by the calibration of the main control PCB.
Once the working temperature is reached, the main control PCB will allow the pump to be operated and the
machine will now be ready to run.

Haze machine principles:
The JEM ZR24/7 and Magnum Hazer work on the same smoke generation principles as the JEM / Martin
smoke machines.
The only difference is the smoke output on a hazer exits into a metal chamber where there is a fan creating a
fast moving air stream. This air stream disperses the smoke output and creates the haze.
Again the principles are identical to that of a conventional smoke machine.
There is a pump, heat exchange, PCBs and onboard controls. The major difference is the air chamber.
A radial fan is used with this system. It is used to allow the exiting smoke to have the maximum dispersal.
As with several of the smoke machines, the haze machine has a low fluid shut off system. This is an
electronic temperature control device that measures the temperature of the heat exchange over a short
period. If the temperature has not changed but the unit has been pumping; the unit will assume that the
system has run out of fluid and shut down. This prevents the system from running dry and burning out
the pump.

3

CE mark
All products that are produced by JEM / Martin carry the CE Certification.
These products meet the requirements of the following EC Standards and as such, comply with the EMC
(Electromagnetic Compatibility) and LVD (Low Voltage Directives), directives of the European Community:
EN 50 081-1 1992

Generic Emission Standard for domestic and light Industrial environments.

EN 50 082-1 1992

Generic Immunity Standard for domestic and light Industrial environments.

EN 60 335-1 1995

Safety of household and similar electrical appliances

These standards reference the following European standards:
Emissions:
EN 55 022 /B

RF voltage and field strength

EN 60 555

Harmonic current content

EN 55 014

RF voltage (discontinuous)

Immunity:
IEC 801-2

Electrostatic discharge to case

IEC 801-4

Common mode fast transients

These standards also meet the requirements of CISPR 22.
JEM did not carry the CE mark on products that were produced prior to 1995.
These products can be identified by either the DIN/XLR socket on the rear or top of the unit or the Mains PCB:
If the unit has a 5 pin DIN or a 4 pin XLR without the CE text on the rear, the unit is classed as NON-CE.
If the PCB has a 12 pin Molex connector fitted to it, this is classed as a NON-CE unit.

4

Searching for information on the INTERNET
If you require information with regards to JEM / Martin Smoke, Haze and Heavy Fog products an ideal place to
start is the Internet.
Martin has a dedicated team of staff who are constantly monitoring and updating the information that is placed
onto the INTERNET. This is to ensure that the best possible service is being given to not just dealers and end
users but also to internal staff.
Locating information is simple:
First go to: www.jemsmoke.com
Here you will find information on all of our current range of products including news, bulletins,
specifications and even videos of machines in action.
To access support information:
On the left hand side of the screen there are several different categories.
Click on SUPPORT.
This will bring you to the SMOKE USER SUPPORT page.
If you have a LOGIN NAME AND PASSWORD then press the LOGIN icon at the top of the page and
enter your username and password into the relevant boxes.
(If you do not have a LOGIN NAME you can still use the site, just with limited access to information)
Select SMOKE from the menu on the left hand side.
Go to the PRODUCTS MENU and choose the PRODUCT you require information on.
Now go to the CATEGORY menu and select which piece of information you require (parts,manuals, etc)
Once you have done this press the SEARCH icon.
All of the information relevant to the product you have chosen will now be displayed.
A LOGIN is required for access to TECHNICIAN and DISTRIBUTOR SUPPORT areas.
Please direct all inquires regarding access to your national distributor.

5

Which fluid can I use with my machine?
X=NO
O=YES

ZR12 AL / DMX

Pro-Smoke
Studio
DX Mix

Pro-Smoke
Super
ZR Mix

Pro-Smoke
Highdensity SP
Mix

O

O

O

I-Fog

Reg. DJ
Fluid

O

O

Party Pack

X

Pro Haze

X

Heavy Fog
Fluid
B2 Mix

X

Heavy Fog
Fluid
C3 Mix

X

What can my machine do?
The ZR12 brothers are mid-sized, portable fog machines with enhanced output to provide a continuous flow of
dry dense fog.
Distinguished from each other by their features of control, the ZR12 AL uses a multifunctional remote, while the
ZR12 DMX has added DMX input for extra flexibility and control. These individual command features allow you
to equip yourself with the right tool for the right job.
The ZR12 DMX can be programmed into any DMX controller and easily incorporated into any light show design.
Additionally, the DMX interface features a test fire button that enables operation without the DMX connection.
The ZR12 AL provides an economical solution with a built in remote for easy command access.
The ZR12 AL and ZR12 DMX are extremely quick to heat up, meaning greater control of fog when you want it.
Both the ZR12 AL and ZR12 DMX are suited for a wide variety of applications. From rental to theatres, TV
studios and clubs.
You can use either control option in either machine for greater flexibility of use. (ZR12 AL controller in ZR12
DMX machine and vice versa).
Create a greater accuracy of fog placement with the ZR ducting system. Available as an accessory to the whole
ZR family, the ducting extension ensures uniformity and coverage in any environment.
“The ZR12 AL is the result of classical Jem design principles. Electronic pump ramping provides continuous and
even fog output. Soft start electronics gives a low level of operating noise, ideal for TV and theatre
environments. Overheat protection is provided by the Direct Thermal Protection device. Output has been
enhanced through a 1000W vaporizing chamber and unlike other machines of its size; the ZR12 AL is
extremely quick to heat-up meaning greater control of fog when you want it.
Jem’s unique "8 x Mode" expands the time capability of the standard timer settings by multiples of 8, far beyond
those normally found on fog machine remotes.
And uniquely for a machine of its class, multiple machines can be linked and operated from the multifunctional
remote control. Auto timer and fog level controls are available as well.”
“The machine includes all the same features as the ZR12 AL yet has added DMX input via a specially designed
on-board interface for extra flexibility and control.
The ZR12 DMX can be programmed into any DMX controller and easily incorporated into any light show design.
Additionally the DMX interface features a test fire button that enables operation without the DMX connection.
The ZR12 DMX is the result of classical Jem design principles. Electronic pump ramping provides continuous
and even fog output. Soft start electronics gives a low level of operating noise, ideal for TV and theatre
environments and for ultimate flexibility multiple machines can be operated from a single remote.
Overheat protection is provided by the Direct Thermal Protection device. Output has been enhanced through a
1000W vaporizing chamber and unlike other machines of its size; the ZR12 DMX is extremely quick to heat-up
meaning greater control of fog when you want it.”

6

Specifications (AL):
Physical

Performance

Control and Programming

Length: 500 mm
Width: 225 mm
Height: 165 mm
Dry weight: 11 kg
Max. smoke output (approx.): 500 m3 per minute
Max. operating time at full output (approx.): 80 mins
Operating time: Continuous, automatic level adjustment
Warm-up time: Approx. 7 minutes
Control options: Remote control (supplied) or DMX with optional DMX interface module
Remote control features: Instant or timer-controlled output, 0-100% adjustable output level
Timer Range: Delay 2-18 secs (X1), 16-144 secs (X8) / Run Time 2-18 secs (X1), 16-144 secs (X8)

Fluid System

Fluid pump: Oscillating piston, high pressure
Onboard fluid capacity: 2.5 l
Max. fluid consumption at peak output: 75 ml per minute

Construction

Housing: Steel & aluminium
Heat exchanger: 1000 W, direct thermal protection

Installation
Connections

Electrical

Typical Power and Current

Thermal

Orientation: Floor (No Flying Kit Available)
Remote control: 5-pin DIN
0-10 V analogue: 5-pin DIN
Power cable entry: Hard-wired
AC power (EU models): 220-240 V nominal, 50 Hz
AC power (US models): 110-120 V nominal, 60 Hz
Main fuse (220-240 V power): 5 AT (slow blow)
Main fuse (110-120 V power): 10 AT (slow blow)
US model
110 V, 60 Hz: 1070 W, 9.72 A
115 V, 60 Hz: 1169 W, 10.16 A
120 V, 60 Hz: 1273 W, 10.61 A
EU model
220 V, 50 Hz: 899 W, 4.08 A
230 V, 50 Hz: 982 W, 4.27 A
240 V, 50 Hz: 1070 W, 4.45 A
Measurements made at nominal voltage. Allow for a deviation of +/- 10%.
Maximum ambient temperature (Ta max.): 40° C
Exterior surface temperature, steady state: 50° C
Max. nozzle temperature: 200° C

Approvals

EU safety: EN 50 081-1, EN 50 082-1
EU safety: EN 60 335-1 (1995)
Accessories

Ordering Information

Service Info (internal only - do not publish)

Pro Smoke Studio (DX Mix) fluid, various sizes available
Pro Smoke Super (ZR Mix) fluid, various sizes available
Pro Smoke Super (Fragranced) fluid, various sizes available
Pro Smoke High Density (SP Mix) fluid, various sizes available
I-fog fluid, various sizes available
Ducting Kit (Including adapter and 5m of 4-inch (104mm) ducting): P/N 92625004
DMX Interface ZR12: P/N 92765015
JEM ZR12 AL, 110V: P/N 92215101
JEM ZR12 AL, 240V: P/N 92215100
Cooling time before service or maintenance: 20 minutes
Minimum clearance around air vents: 0.20 m

7

Specifications (DMX):
Physical

Performance

Control and Programming

Length: 500 mm
Width: 225 mm
Height: 165 mm
Dry weight: 11 kg
Max. smoke output (approx.): 500 m3 per minute
Max. operating time at full output (approx.): 80 mins.
Operating time: Continuous, automatic level adjustment
Warm-up time: Approx. 7 minutes
Control options: Remote control (supplied), DMX, 0-10 V analogue
Remote control features: DMX Interface with manual push button
DMX channels: 1
Protocol: USITT DMX512/1990

Fluid System

Fluid pump: Oscillating piston, high pressure
Onboard fluid capacity: 2.5 l
Max. fluid consumption at peak output: 75 ml per minute

Construction

Housing: Steel & aluminium
Heat exchanger: 1000 W, direct thermal protection

Installation
Connections

Electrical

Typical Power and Current

Thermal

Orientation: Floor (No Flying Kit Available)
Remote control: 5-pin DIN
DMX data: 3-pin locking XLR
0-10 V analogue: 5-pin DIN
Power cable entry: Hard-wired
AC power (EU models): 220-240 V nominal, 50 Hz
AC power (US models): 110-120 V nominal, 60 Hz
Main fuse (220-240 V power): 5 AT (slow blow)
Main fuse (110-120 V power): 10 AT (slow blow)
US model
110 V, 60 Hz: 1070 W, 9.72 A
115 V, 60 Hz: 1169 W, 10.16 A
120 V, 60 Hz: 1273 W, 10.61 A
EU model
220 V, 50 Hz: 899 W, 4.08 A
230 V, 50 Hz: 982 W, 4.27 A
240 V, 50 Hz: 1070 W, 4.45 A
Measurements made at nominal voltage. Allow for a deviation of +/- 10%.
Maximum ambient temperature (Ta max.): 40° C
Exterior surface temperature, steady state: 50° C
Max. nozzle temperature: 200° C

Approvals

EU safety: EN 50 081-1, EN 50 082-1
EU safety: EN 60 335-1 (1995)
Accessories

Ordering Information

Service Info (internal only - do not publish)

Pro Smoke Studio (DX Mix) fluid, various sizes available
Pro Smoke Super (ZR Mix) fluid, various sizes available
Pro Smoke Super (Fragranced) fluid, various sizes available
Pro Smoke High Density (SP Mix) fluid, various sizes available
I-fog fluid, various sizes available
Ducting Kit (Including adapter and 5m of 4-inch (104mm) ducting): P/N 92625004
DMX termination plug, 3-pin male XLR: P/N 91613017
JEM ZR12 DMX, 120 V: P/N 92215111
JEM ZR12 DMX, 240 V: P/N 92215110
Cooling time before service or maintenance: 20 minutes
Minimum clearance around air vents: 0.20 m

8

SERVICE OF MACHINES
TOOLS AND THINGS:
For successful servicing of a machine you will need some basic tools which are in good working order
and the right size for the job. Other tools / equipment are available for specific jobs but in most cases these are
not needed for general service.
Equipment needed:
Screwdrivers
Pozidrive, size 1 and 2
Flat tip, size small and medium
Wrenches
7mm
12mm x2
Pliers
Needle Nose, small
Wire Cutters, small
Digital Multi Meter (With ability to measure mV)
Additional Items / recommended:
Cable Ties (p/n 13104000)
Silicone Sealant
JEM Calibration Box (p/n 92620005)
Paper towels (or other absorbent material)
Ammeter (For measuring current draw of machine – could be handheld or bench mounted)
Epsilon 5 Portable ISP Programmer (p/n 50502004)
Common Sense !!

WARNING – MAINS VOLTAGE
DISCONNECT FROM MAINS SUPPLY
BEFORE REMOVING COVERS
AND SERVICING THIS MACHINE

PROCEED WITH EXTREME CAUTION

9

ZR12 MACHINE OVERVIEW
The Outside:
ANALOGUE
CONTROL

3 PIN DMX

STATUS LIGHTS

ANALOGUE LINK

10

Opening The Machine:
1. DISCONNECT FROM MAINS SUPPLY.
2. Remove the 10 M4x10 pozidrive TAPTITE screws from the outside of the machine and store
safely.
3. Lift off the lid.

The Inside:

MAINS INPUT

PUMP
EARTH POINT
HEAT
EXCHANGE

THERMAL TRIP

THERMOCOUPLE

ANALOGUE LINK
(NOT REMOTE SOCKET)

ELEMENTS

MAINS INPUT

COPPER FLUID
LINE

BRASS FITTINGS

11

HOW TO….
REFER TO SCHEMATICS / DIAGRAMS IN THE APPENDIX FOR MORE DETAILS
How To Change A Heat Exchange:

1. Always try to change a HEAT EXCHANGE when it is cold as the exposed metal parts can be
VERY HOT.
2. DISCONNECT FROM MAINS SUPPLY.
3. Remove TOP COVER.
4. Disconnect the THERMOCOUPLE from the MAIN PCB.
5. Disconnect the HEAT EXCHANGE POWER WIRES from the terminals of the PCB.
6. Remove the negative (BLUE) wire from the heater.
7. Undo the brass nut that connects the BRASS ASSEMBLY to the HEAT EXCHANGE and
disconnect the fluid line from the pump.
8. Undo the 4 screws that hold the HEAT EXCHANGER to the CHASSIS.
9. Withdraw the NOZZLE of the heater through the hole and remove the heat exchange from the
chassis.

Refitting Your New Heater:
1.
2.
3.
4.
5.
6.

Replace heat exchange in chassis NOZZLE FIRST.
Screw the 4 screws back in through the bottom of the chassis
Replace the negative (BLUE) wire to the HEAT EXCHANGER ELEMENT.
Reconnect the HEATER POWER wires to the TERMINALS of the PCB.
Using a NEW OLIVE refit the COPPER FLUID LINE to the PUMP.
RECALIBRATE the temperature of the unit. (See Calibration Section)

12

How To Change A Pump:

1.
2.
3.
4.
5.
6.

DRAIN ALL FLUID FROM THE SYSTEM FIRST.
DISCONNECT FROM MAINS SUPPLY.
Remove TOP COVER.
Disconnect the POWER wires from the PUMP.
Disconnect the BLACK RUBBER FLUID LINE from the rear of the PUMP.
Move the fluid line out of the way. (BE CAREFUL OF FLUID COMING BACK DOWN THE
PIPE)
7. Disconnect the COPPER FLUID LINE from the front of the pump.

8.
9.
10.
11.

Unhook the rear RUBBER MOUNT from the pump.
Withdraw the pump from the front RUBBER MOUNT.
Remove the PUMP from the machine.
Remove the BRASS FITTING from the front of the PUMP.

REFITTING:
12.
13.
14.
15.
16.
17.
18.

Fit the BRASS FITTING to the front of the pump using a THREAD SEALANT COMPOUND.
Fit the new PUMP to the CHASSIS by inserting the front end first into the RUBBER MOUNT.
Hook the rear mount onto the back of the pump.
Reconnect the BLACK RUBBER PIPE.
Reconnect the POWER wires to the PUMP – BROWN INSIDE / BLUE OUTSIDE.
Turn machine on and RE-PRIME the system.
Refit TOP COVER.

13

How To Change A PCB:
REFER TO SCHEMATICS / DIAGRAMS IN THE APPENDIX FOR MORE DETAILS

PCB
1. DISCONNECT FROM MAINS SUPPLY.
2. Remove TOP COVER.
3. Remove the 2 screws at the bottom of the PCB HEATSINK from INSIDE THE BOTTLE
COMPARTMENT holding the nut that is inside the PCB compartment.
4. Disconnect the PCB WIRING LOOMS from the PCB (Note orientation before removal).
5. Remove the 4 PLASTIC RIVETS from the 5-pin din sockets.

6. The PCB is mounted on 2 mounting posts which will need to be squeezed to remove the pcb.
7. Remove the HEATSINK from the PCB by removing the 2 screws/nuts/washers.
REFITTING:
8. Fit the HEATSINK to the PCB using the 2 screws/nuts adding THERMAL TRANSFER
PASTE underneath component Q6.
9. Fit new PCB to the mounting posts.
10. Insert the 4 PLASTIC RIVETS into the din sockets.
11. Insert the 2 screws into the heatsink from the bottle compartment and secure with the nuts in
the PCB compartment.
12. Reconnect the PCB WIRING LOOMS (Observe polarity).
13. Refit the TOP COVER.

14

Calibration:
1.
2.
3.
4.
5.

Set the JEM CALIBRATION BOX to the required mV setting (13.4mV).
Make sure the RAMP BUTTON on your CALIBRATION BOX (GREY) is OFF.
Remove the TOP COVER.
Disconnect the THERMOCOUPLE from the PCB.
Connect the RED TERMINAL of the CALIBRATION BOX to the POSITIVE (+)
THERMOCOUPLE connector of the PCB.
6. Connect the BLACK TERMINAL of the CALIBRATION BOX to the NEGATIVE (-)
THERMOCOUPLE connector of the PCB.
7. Turn the machine on and tweak the TEMPERATURE CALIBRATION POT until the RED
(HEATING) LED FLASHES.

8. IF YOU PRESS THE RAMP BUTTON IN THE LED SHOULD GO OUT AND COME BACK
ON AGAIN WHEN YOU RELEASE THE BUTTON.
9. Disconnect the CALIBRATION BOX from the THERMOCOUPLE connectors.
10. Replace the THERMOCOUPLE onto the DMX/PROGRAM PCB (PRE 11/06: YELLOW = +
BLUE = - / POST 11/06: BLACK = + WHITE = -)
11. Turn the machine on and check for current draw.
12. Let the machine heat up and check using a digital volt meter that the RED (HEATING) LED
turns OFF at the correct point.
13. The GREEN (OK) LED should turn on about 1mV lower than the peak temperature setting.
(RED LED TURNING OFF)
14. TEMPERATURE CALIBRATION IS NOW COMPLETE.

15

SPARE PARTS LISTS
240V
Part
PUMP
PCB

MAIN

Spare Part Number
05761003
62020002

PCB

REMOTE

62020505

HEAT
EXCHANGE
HEAT
EXCHANGE
HEAT
EXCHANGE
HEAT
EXCHANGE

COMPLETE

HEAT
EXCHANGE
HEAT
EXCHANGE
HEAT
EXCHANGE
CASEWORK
CASEWORK
CASEWORK
CASEWORK

Description

BARE Inc BRASSWORK

26460670

BRASSWORK ONLY

26460170

CASEWORK

n/a

INSULATION

26520070

CASEWORK AVAILABLE
SEPARATELY - CONTACT jemservice@martin.dk
PRE CUT INSULATION KIT

THERMAL TRIP ONLY

05041021

TRIP SWITCH ONLY

THERMAL TRIP Inc LOOM

TRIP SWITCH INCLUDING LOOM

CARRY HANDLE (PLASTIC)
TOP LID
MAIN CHASSIS

19200050
26561670
26561660

34300521
92765002

OTHER

BOTTLE
REMOTE CONTROL
ANALOGUE
REMOTE CONTROL DMX

92765015

OTHER

FLUID LINE ASSEMBLY

62520045

OTHER

MAINS SWITCH

05523021

OTHER

WIRING LOOMS COMPLETE

OTHER

STICKERS COMPLETE

OTHER
OTHER

Comments
240V RED BODY
240v MAIN CONTROL PCB TESTED
TESTED w/o BUTTON TOPS OR
KNOBS
COMPLETE BUILT UP HEAT
EXCHANGE c/w BRASS FITTINGS
BARE EXCHANGE (No insulation
or casework) c/w BRASS FITTINGS
BRASS FITTINGS ONLY

PLASTIC CARRY HANDLE
TOP LID
MAIN CHASSIS - BARE
OTHER CASEWORK IS
AVAILABLE - CONTACT jemservice@martin.dk
2.5L FLUID BOTTLE
COMPLETE ANALOGUE REMOTE
CONTROL
COMPLETE DMX INTERFACE /
REMOTE CONTROL
INCLUDES CAP, FILTER AND
CONNECTOR
ILLUMINATED MAINS ON/OFF
SWITCH
ALL WIRING LOOMS FOR
MACHINE
ALL STICKERS / LABELS FOR
MACHINE

16

110V
Part
PUMP
PCB

Description
MAIN

Spare Part Number
05761001
62020004

PCB

REMOTE

62020505

HEAT
EXCHANGE
HEAT
EXCHANGE
HEAT
EXCHANGE
HEAT
EXCHANGE

COMPLETE

Comments
110V RED BODY
110v MAIN CONTROL PCB TESTED
TESTED w/o BUTTON TOPS OR
KNOBS
COMPLETE BUILT UP HEAT
EXCHANGE c/w BRASS FITTINGS
BARE EXCHANGE (No insulation
or casework) c/w BRASS FITTINGS
BRASS FITTINGS ONLY

BARE Inc BRASSWORK

26460830

BRASSWORK ONLY

26460170

CASEWORK

n/a

HEAT
EXCHANGE
HEAT
EXCHANGE
HEAT
EXCHANGE
CASEWORK
CASEWORK
CASEWORK
CASEWORK

INSULATION

26520070

CASEWORK AVAILABLE
SEPARATELY - CONTACT jemservice@martin.dk
PRE CUT INSULATION KIT

THERMAL TRIP ONLY

05041021

TRIP SWITCH ONLY

CARRY HANDLE (PLASTIC)
TOP LID
MAIN CHASSIS

19200050
26561670
26561660

OTHER
OTHER

34300521
92765002

OTHER

BOTTLE
REMOTE CONTROL
ANALOGUE
REMOTE CONTROL DMX

92765015

OTHER

FLUID LINE ASSEMBLY

62520045

OTHER

MAINS SWITCH

05523021

OTHER

WIRING LOOMS COMPLETE

OTHER

STICKERS COMPLETE

THERMAL TRIP Inc LOOM

TRIP SWITCH INCLUDING LOOM
PLASTIC CARRY HANDLE
TOP LID
MAIN CHASSIS - BARE
OTHER CASEWORK IS
AVAILABLE - CONTACT jemservice@martin.dk
2.5L FLUID BOTTLE
COMPLETE ANALOGUE REMOTE
CONTROL
COMPLETE DMX INTERFACE /
REMOTE CONTROL
INCLUDES CAP, FILTER AND
CONNECTOR
ILLUMINATED MAINS ON/OFF
SWITCH
ALL WIRING LOOMS FOR
MACHINE
ALL STICKERS / LABELS FOR
MACHINE

APPENDIX
Fuse Ratings
Fuse

240V

110V

External

6.3A

10A

17

ZR12 DMX REMOTE CONTROL XLR PLUG PIN OUTS

2
4
1

1 - NOT USED

5

4 - NOT USED

3

2 - BLACK (GND).
5 - WHITE (0 - 10v)
3 - YELLOW (+16v).

VIEWED FROM THE SOLDER SIDE
OF THE DIN PLUG

PIN OUT DESCRIPTION
1, NOT USED
4, NOT USED
2, GND TO DMX CARD
5, TO + TERMINAL OF SWITCH
(STRAIGHT TO SWITCH, NOT DIODE ON BLUE WIRE)
3, TO SWITCH - TERMINAL
ZR12 DMX Remote Pins
Drawing No. 2012/1A
Drawn by :

GS

28/03/2006

ZR12 DMX REMOTE TEST SWITCH

WHITE
YELLOW

BLUE
IN4007

BACK OF SWITCH

ZR12AL REMOTE CONTROL DIN PLUG PIN OUTS

2
4

1 - YELLOW (READY).

5

4 - WHITE (HEAT).

3

1

2 - BLACK (GND).
5 - BLUE (0 - 10v)
3 - RED (+16v).

VIEWED FROM THE SOLDER SIDE
OF THE DIN PLUG

PIN OUT DESCRIPTION
1, GND WHEN MACHINES UP TO TEMPERATURE
4, GND WHEN MACHINES HEATING
2, GND
5, 0 - 10v INPUT, NEEDS 1.5v TO HEAT AND
2v -10v PUMP SPEED WHEN MACHINES READY
3 +16v OUTPUT
ZR12AL Remote Plug Pin
Drawing No. 2011/1A
Drawn by :

GS

28/03/2006

ZR12AL REMOTE PCB PIN OUTS

1

2

3

PIN
1, BLACK
2, BLUE
3, RED

ZR12AL REMOTE
PCB PIN OUTS
Drawing No. 2011/2A
Drawn by : GS 28/03/2006

NO OUTPUT

YES

Is the
machine fully
heated and
ready to run?

Is the machine
plugged in, turned on
at the mains AND the
power switch set to
ON?

NO

Check power
and turn on

NO

See HEATER PROBLEMS

YES

Is the pump
running?

NO

See PUMP PROBLEMS

YES

Undo the brass fitting to the heater / fluid line and run the machine.

Is fluid coming out of
the brass fitting?

NO

YES

Pump seized – Replace pump

Heater is blocked – Replace heater

PUMP PROBLEMS

Is power getting to the pump?
(set to full power and check 240V / 110V)

NO

See PCB PROBLEMS

YES

Does piston seem to
be moving?

NO

PUMP SEIZED - REPLACE

YES

Is fluid travelling
through pump?

NO

PUMP BLOCKED - REPLACE

YES

Fault may be in fluid line / heater

HEATER PROBLEMS
YES

NO

Is the heater heating?

Overheating

YES

YES

Check thermocouple
OK?

CHECK
CALIBRATION

NO

Is power getting to the heater?
(check 240V / 110V)

REPLACE
HEATER

NO

YES

See PCB
PROBLEMS

Is power getting to the
thermal trip?
(check 240V / 110V)

NO

YES

YES

Is power getting through
the thermal trip?
(check 240V / 110V)

THERMAL TRIP
FAULT – RESET /
REPLACE
NO

Disconnect power and remove power loom from element connectors

Measure across the elements for continuity and check for earth leaks

Normal Ohms reading?

NO

Earth leakage?
YES

YES
OPEN CIRCUIT
HEATER REPLACE
See PCB
PROBLEMS

OPEN CIRCUIT
HEATER REPLACE

See PCB
PROBLEMS

NO

PCB PROBLEMS

APART FROM THE OBVIOUS FUSES /
WIRING ETC. PCB FAULT FINDING IS
TOO IN-DEPTH TO COVER HERE –
PLEASE REFER SERVICING / REPAIR
TO A QUALIFIED ENGINEER



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2007:09:18 15:12:46Z
Modify Date                     : 2007:09:18 15:21:50+01:00
Page Count                      : 29
Has XFA                         : No
Creation Date                   : 2007:09:18 15:12:46Z
Author                          : gary.swallow
Producer                        : Acrobat PDFWriter 5.0 for Windows NT
Mod Date                        : 2007:09:18 15:21:50+01:00
Metadata Date                   : 2007:09:18 15:21:50+01:00
Title                           : ZR12 service manual.doc
Creator                         : gary.swallow
EXIF Metadata provided by EXIF.tools

Navigation menu