SS 10 3G Telkom User Manual

User Manual: SS-10-3G-Telkom-User-Manual

Open the PDF directly: View PDF PDF.
Page Count: 20

DownloadSS-10 3G Telkom User Manual SS-10-3G-Telkom-User-Manual
Open PDF In BrowserView PDF
SS-10 3G
FIXED CELLULAR TERMINAL

USER MANUAL

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 1 of 20

Revision History:
Revision 01

Original document

12 August 2010

CONTENTS
1
2
2.1
2.2
2.3
3
3.1
3.2
4
5
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
6
6.1
7
7.1
7.2
7.3
7.4
7.5
7.6
8
9
10

INTRODUCTION.................................................................................................3
FEATURES .........................................................................................................4
PHYSICAL FEATURES .............................................................................................. 4
SOFTWARE FEATURES............................................................................................. 4
MAINTENANCE FEATURES ..................................................................................... 4
DESCRIPTION ....................................................................................................6
FRONT VIEW .............................................................................................................. 6
REAR VIEW ................................................................................................................ 6
SETUP ................................................................................................................7
SETTABLE PARAMETERS ...............................................................................8
BASIC SETUP .............................................................................................................. 8
REPORTING SETUP ................................................................................................... 9
SIM & NETWORK..................................................................................................... 10
AUTHORIZED USER ................................................................................................ 11
HARDWARE SETTINGS .......................................................................................... 11
POWER DOWN TIME ............................................................................................... 11
CALL BARRING ....................................................................................................... 12
MISCELLANEOUS .................................................................................................... 12
CALL BACK .............................................................................................................. 12
SETUP INFORMATION ............................................................................................ 13
SERIAL PORT COMMANDS ............................................................................13
SIMPLIFIED SERIAL PORT COMMANDS .............................................................. 13
SETUP OF THE UNIT BY USING THE SS-10 TOOL.......................................14
MAIN WINDOW ........................................................................................................ 14
CALL PARAMETERS ............................................................................................... 15
CALL BACK .............................................................................................................. 16
CALL BARRING ....................................................................................................... 17
SMS OPTIONS ........................................................................................................... 18
NETWORK ................................................................................................................ 19
UPGRADE OF THE SS-10 3G FIRMWARE .....................................................20
TECHNICAL SPECIFICATIONS.......................................................................20
CONTACT DETAILS .............................................. Error! Bookmark not defined.

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 2 of 20

1

INTRODUCTION
The purpose of the SS-10 3G Fixed Cellular Terminal (FCT) is to provide a means of
making telephone calls where there is no fixed line infrastructure or where it may be
more cost effective to use the GSM/3G infrastructure for carrying the call.
ARCHITECTURE

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 3 of 20

2

FEATURES

2.1

PHYSICAL FEATURES

Matches to complex line impedance

Power saving feed-bridge

Signal level indicator LEDs

Busy indicator

Network indicator

SMA antenna connector

Module On/Off switch allows Network Detach

Power supply 300mA at 12 VDC

RJ11 connector for telephone

DB9 connector for programming

900/1800 MHz operation in 2G GSM mode

900/2100 MHz operation in 3G UMTS mode (additional 850MHz optional)

2.2

SOFTWARE FEATURES

Comfort Tone

CLI restriction

Settable digit count

Settable dial timeout

Automatic call termination

Transmit & receive levels adjustable

Optional reversal

Optional line current break

Optional periodic module reboot

Full rate, enhanced full rate & half rate operation

Supports Adaptive Multi-rate (AMR)

Preferred network selection (Network locking)

2G, 3G or automatic network selection

Dial-In modem functionality (2G mode only)

4 minute timer to reset module if not registered on the network

128 Programmable Call Back numbers

Settable SIM Pin Number

Supports International SIM card operation

2.3

MAINTENANCE FEATURES

Routine periodic SMS reports
o
Feed bridge voltages
o
Number of forcedly cut calls
o
Number of unanswered calls
o
Number of answered calls
o
Total duration of answered calls

SMS report on zero traffic (no calls made for specified interval)

Request reports

Request setting information

Change set-up information by SMS

2 authorized maintainers
DOC. NO: SS-10 3G-14 (Rev. 01)

Page 4 of 20



Programmable by serial port, telephone or SMS

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 5 of 20

3

DESCRIPTION

3.1

FRONT VIEW

ON/OFF button
Holding in the On/Off button while the
unit is powered up enables setup mode

SIM card
tray

3.2

1

Press for
opening
SIM tray

Power Indicator
Busy Indicator
Network Indicator

Signal strength
indicator

SMA antenna
connector

REAR VIEW

4

Line Connector
RJ-11 Connector
(Only pins 2 & 3
are used)

PC Connector
DC Connector
DB9 Female - Used for Connects a DC voltage
setup purposes
between 12V and 18V to
Use a standard PC
the unit
Pin
Description
serial cable for
connecting the unit to Inside DC positive voltage
Outside
GROUND
a PC

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 6 of 20

4

SETUP
Setup of the SS-10 3G can be done by using one of the following
methods:





SMS Setup Method: Sending SMS commands to the unit;
Telephone Setup Method: Using a telephone connected to the SS-10 3G;
PC Serial Port Setup Method: Sending commands to the unit by connecting it
to a PC and use a Comms package like HyperTerminal, or
PC Serial Port Setup Method: Connect the unit to a PC using the SS-10 Tool
package;

Using SS-10 Toolkit
Load the SS-10 Tool and refer to the notes
“Setup of the unit by using the SS-10
3G Tool’

Using a
Telephone

Sending SMS
commands
The format of the commands
using SMS is as follows:

Setup Mode must be enabled.
Holding in the On/Off button
while the unit is powered up
enables setup mode on the SS10 3G.

***
where  is a command number and
 is a value.

Dial the following:

*#
Sending
Commands using
a Comms package

Where nn is the parameter
number and ddd is the
required setting.

From the serial port the format is:

***
or

**,
Where nn is the parameter number and
ddd is the required setting

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 7 of 20

5

SETTABLE PARAMETERS

5.1

BASIC SETUP

Parameter Description

Notes

01

Total Digit Count
Sets the total number of digits required before dialing.
It is recommended that this parameter is set to 10.

02

Dial Timeout
Set dial timeout in 10ths of a second. Normally 4 seconds
This is the time taken before the call proceeds when numbers shorter
than the total digit count are dialed.

03

Call Progress Tones
Enable (1), disable (0)

04

Polarity Reversal Signalling
Set reversal time in 10ths of a second. To enable reversal on answer
add 100 to the number input. E.g. 04*20 sets the time to 2.0 seconds
without reversal on answer and setting 04*120 sets it to 2.0 seconds
WITH reversal on answer.

05

Break Pulse Signaling
Set the break time in 10ths of a second. Some PABX systems require a
current break to indicate that the call has terminated. The SS-10 3G
can provide such a break. If it is not required then set this parameter
to 0.

06

Call Line Identification
Restrict CLI (1) or allow CLI (0).
Transmit Levels

07

Relative Level
-12 dB
-6 dB
0 dB
+6 dB
Receive Levels

08

Relative Level
-12 dB
-6 dB
0 dB
+6 dB

DOC. NO: SS-10 3G-14 (Rev. 01)

Set transmit levels 0-255 (64 normal)
Value
32
64
128
255

Description
Softer
Factory Setting
Louder
Loudest

Set receive levels 0-255 (64 normal)
Value
32
64
128
255

Description
Softer
Factory Setting
Louder
Loudest

Page 8 of 20

5.2

REPORTING SETUP

Parameter Description

Notes

10

No Call SMS Report
Set the interval, in minutes, after which a report may be sent by SMS if
no calls have taken place.
Set to 0 to disable ‘no call reporting’.

11

Routine Reports
Set the interval, in minutes, between routine reports that will be sent
by SMS to the pre-programmed destination.
Set to 0 to disable routine reporting.

12

SMS Report Destination
Sets the destination number for SMS report. Please include country
code. Eg. +27828221381

13

SS-10 3G Identity
This command is only available from the serial port. It is used to set a
16 character ID so that the SS-10 3G can identify itself in SMS
messages that are sent.

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 9 of 20

5.3

SIM & NETWORK

Parameter Description

Notes

Sets the PIN
Sets the PIN (SimPin1). It is only needed if the SIM card has its PIN
set.

30

Using a PIN locked SIM
The SIM can be loaded into the SS-10 3G using the command:
**30*nnnn
where nnnn is the PIN number. It is important to make sure that the
PIN is entered correctly. If the PIN is not correct then the SS-10 3G
will output a message on the serial port indicating this. It will also flash
the IN USE and NETWORK LED’s in an alternating pattern until it is
powered down. Note that after 3 attempts the SIM will be blocked and
the PUK will have to be used to unblock the SIM. This will need to be
done using a normal GSM handset or the SS-10 Tool.
Using a BLANK SIM
If the SIM card is setup without a PIN, no further action needs to be
taken, as the SS-10 3G will recognize that no PIN is required and it
will automatically log onto the network.
Set Network Operator
5 digit network code - use space for automatic network selection.

31

34

35

Vodacom
65501

MTN
65510

Cell C
65507

Select Network Band (GSM/3G)
The unit can be made to only log onto the 2G GSM network (0) or only
the 3G UMTS network (2). Alternatively the unit can be set to
automatically select the network type with the best signal (1).
Enable International Callback
This feature is for use with the eMobile International Callback SIM. (1)
enables the feature, (0) disables the feature. NB. Please remember to
set the Dialled Digit Count (see above) to a higher value (16
recommended) to support the length of international numbers. Line
current will be disconnected for +-10 sec if a call is terminated during
setup. This allows time for proper call clearing on the network.

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 10 of 20

5.4

AUTHORIZED USER

Parameter Description

32

33

5.5

Notes

Authorised User 1
Gives authorisation to user 1 for controlling access to the SS-10 3G
unit via SMS by entering the user’s numbers. Country code to be
included, e.g. +27828221381
Authorised User 2
Gives authorisation to user 2 for controlling access to the SS-10 3G
unit via SMS by entering the user’s numbers. Country code to be
included, e.g. +27828221381

HARDWARE SETTINGS

Parameter Description

Notes

40

On-Hook Voltage
The On-Hook voltage can be set with this command. The allowed
range is from 20 volts to 45 volts. Nominal value is 35 volts.

41

Off Hook Voltage
The Off-Hook voltage is set using this command. It can be set from 18
to 40 volts. The nominal value is 25 volts. This allows power usage to
be reduced during conversations, which reduces heating in confined
spaces.

42

Peak Ring Voltage
Sets the peak ring voltage. The range is 40 to 60 volts. The factory
setting is 65 volts, normally this setting will not require adjustment.

5.6

POWER DOWN TIME

Parameter Description
55

Power Down Time
Time in minutes between forced network logoffs.

56

Automatic call termination
Time in minutes before call termination. Enter 0 to disable feature.

DOC. NO: SS-10 3G-14 (Rev. 01)

Notes

Page 11 of 20

5.7

CALL BARRING

Parameter Description
60

61

62

65

5.8

Notes

Incoming Calls
Prohibits incoming calls (1), allows incoming calls (0).
Display Number Table
Used to display the number list.
An extra digit will precede the number.
(2) Indicates an allowed number, (1) indicates a barred number.
Note: Command will only work in serial setup mode
Add Number
Add a ‘2’ before the number to allow the number.
Add a ‘1’ before the number to bar the number.
Set ‘Need Allowed’
When this is set to ‘1’, all numbers will be barred by default and
allowed numbers have to be explicitly enabled.

MISCELLANEOUS

Parameter Description
80

Clear Totals
Resets the report values

81

Set Report Timer
Sets the time interval for the report timer.

5.9

Notes

CALL BACK

Parameter Description
43

Set National Dial Code
Sets the national dial code that will be recognised eg.+27

70

Erase Call Back Entries.
Erase all the call back entries by using **70*112233

71

Add Entry
Add a number to the call back list. E.g. **71*0821111111
Please note that the number must begin with a “0”

72

Delete Entry
Delete a number from the call back list. E.g. **72*0821111111

73

Allow Any Number
Set to 1 allows any number to be called back
Set to 0 enforces the listed numbers

DOC. NO: SS-10 3G-14 (Rev. 01)

Notes

Page 12 of 20

5.10

SETUP INFORMATION

Parameter Description

Notes

96

Reboot the GSM Module
Should be used after level changes.

97

Sends a report back to originator.

98

Sends an SMS containing settings.

99

Displays the settings.

6

SERIAL PORT COMMANDS

6.1

SIMPLIFIED SERIAL PORT COMMANDS

Simplified basic commands for entering via the serial port generally used for diagnostic or basic
setup purposes.
Instruction

Description

DR

Gives a short report on state.

AT

Sends the data dddd to the cell module.

RESET

Resets the SS-10 3G.

DIAG

Toggles the diagnostic state of the SS-10 3G.

SMS

Sends a test SMS to the pre-programmed
destination.

***

Sets parameter nn to value ddd.

SETID

Sets the ID of the SS-10 3G to sssss.
This is used to identify the particular SS-10 3G
(site name) when automatic SMS messages are
sent.

SHOWCB

Shows 20 entries starting at entry ‘nn’

DOC. NO: SS-10 3G-14 (Rev. 01)

Notes

Page 13 of 20

7

SETUP OF THE UNIT BY USING THE SS-10 TOOL

7.1

MAIN WINDOW

SS-10 Tool
Main Window
Load the SS-10 Tool
Click on the COM tab
to select the required
COM port if it differs
from the default port.
Set the speed to 9600
baud if it is not detected
automatically.

IMEI +VER

Display the following:
IMEI, Software Revision and Hardware type of the GSM/3G engine.
Displays SS-10 3G firmware revision number.

UpLoad Firmware

To update the firmware, load the Firmware file from the File Menu.
Use UpLoad Firmware button to load the Firmware into the unit.
Refer to the Upgrade Firmware section for the complete procedure.

Show Signal

Tick the Show Signal box for a visual and measured indication of the
signal strength.

Auto Fetch Settings

The SS-10 Tool will automatically fetch the settings from the SS-10 when
the Setup window is opened.

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 14 of 20

7.2

CALL PARAMETERS
Click on SETUP to start with the setup of the SS-10 3G.

Call Parameters:

Call setup, Audio and
Line levels can be
changed in this window.

Call Setup
Dialled Digit Count
Dial Timeout
CLI Restriction
Call Progress Tones
Reversal Time
Reversal on Answer
Break Time
Show for un-answered
call
Audio Parameters
TX Level
RX Level
Line Settings
On-Hook Voltage
Off-Hook Voltage

Sets the total number of digits required before dialing.
It is recommended that this parameter is set to 10.
Sets dial timeout in 10ths of a second
This is the time taken before the call proceeds when numbers shorter
than the total digit count are dialed. Nominal value is 4 seconds
Restricts or allows Call Line Identification.
Enables or disables Call Progress Tones.
Sets reversal time in 10ths of a second.
Enables or disables Reversal on Answer.
Sets the break time in 10ths of a second. Some PABX systems require a
current break to indicate that the call has terminated. If it is not required
then set this to 0.
When ticked the graph will display the reversal sequence for an
unanswered call.
Sets Audio Transmit level. Nominal value is -6 dB
Sets Audio Receive level. Nominal value is -6 dB
The allowed range is from 20 to 45 volts. Nominal value is 35 volts.
It can be set from 18 to 40 volts. The nominal value is 25 volts. This
allows power usage to be reduced during conversations, which reduces
heating in confined spaces.

Ring Voltage
The range is 40 to 65 volts. The factory setting is 50 volts, normally this
setting will not require adjustment

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 15 of 20

7.3

CALL BACK

Call Back:
Call back numbers can be
added in this window.
NB: In some cases, the
network does not issue a
command to disconnect a
busy call. If this is the
case, the call should be
manually terminated when
the ‘busy’ tone is heard to
allow for call back.

Click on Add or Delete to enter or remove the number from the list.

Number

The call back number to be added to the list. NB. This number must
begin with the “0” digit.

Allow Any Number

When ticked, the call back list will be ignored and any incoming call
number will be called back.

National Dial Code

This is the only national dialling code that will be recognised as valid
for call back. Default is +27.

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 16 of 20

7.4

CALL BARRING

Call Barring:
Calls can be barred or
allowed

Enter the first digits of the number needed to recognise the number type.
Select the Type as BARRED or ALLOWED.
Click on Add or Delete to enter or remove the number from the list.

Require Allowed Numbers

If the block is not ticked it will allow all the numbers that are not
barred.

Allow Incoming Calls

The SS-10 3G can be set to allow or ignore incoming calls.

Auto Call Termination

The SS-10 3G can be set to terminate an outgoing call after a set
duration.

Upload Numbers to SS-10

To enable or disable the upload of the Call Barring List to the SS-10
when using the “Update SS-10” button.

Fetch Numbers From SS-10

To enable or disable the download of the Call Barring List from the
SS-10 when using the ‘Fetch Settings’ button.

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 17 of 20

7.5

SMS OPTIONS

SMS Options:
The SS-10 3G can be set
to send fault reporting via
SMS to a required
destination number.
It can authorise two users
to control the unit via
SMS.

Reporting Setup








Feed bridge voltages
Module voltage
Number of unanswered calls
Number of answered calls
Total duration of answered calls
Number of forced call terminations

Report Destination

Destination number for reports to be sent. Country code to be
included, e.g. +27828221381

Report Identity

Identity to be sent with report for identifying the unit. Click on Get IMEI
to retrieve the number from the unit or use any custom text as the
identity.

No Call Report Interval

A report will be sent if no answered calls have been made for this
period of time.

Routine Report Interval

Fixed intervals between sending of reports.

SMS Control Info
Authorised User

Give authorisation to two users for controlling the access to the SS-10
3G unit via SMS by entering the user’s numbers. Country code to be
included, e.g. +27828221381

SMS Service Centre
Number

Enter the SMS service number for the network.

Type

After entering the service number, click on Read to automatically get
‘type’ from the network.

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 18 of 20

7.6

NETWORK

Network:
Select the required
Network and Reset
Interval if needed.
Manage SIM security.

Network Selection

Enable Int. Callback

When using ‘Other’, the 5-digit network operator ID should be
obtained from the local Network Operator. The SS-10 3G can be
forced onto the 2G (GSM) or 3G (WCDMA) band. Alternatively, the
unit can be set to use the band with the best signal (Auto).
This feature is only for use with the eMobile International Callback
SIM. Tick the box to enable the feature. NB. Please remember to set
the Dialled Digit Count (see above) to a higher value (16
recommended) to support the length of international numbers.

Reset Interval

Set the interval in hours and minutes between forced network log-offs.

Current Settings

To query the current status of the SIM. LOCKED or UN LOCK

Set SIM Lock Status

Tick to lock SIM. Enter the pin in the ‘SIM card PIN’ text box.

Change SIM PIN

To change the SIM PIN Number

Set PUK

In the event that the PUK number is required. Sets new PIN.

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 19 of 20

8

UPGRADE OF THE SS-10 3G FIRMWARE

Download Firmware

The latest firmware for the SS-10 3G is available from:

http://www.sstelecoms.com/

Connect unit to PC

Upgrade the
Firmware
by using the
SS-10 Tool

Connect the SS-10 3G unit to the PC by using a serial cable and
make sure it is switched on.

Load the SS-10 3G Tool Program:
•
•
•
•

•

9

Click on ComPort to select the required COM.
Set the BaudRate to 9600.
From the File Menu choose Open and select the required
Firmware file.
Click the UpLoad Firmware button to upload the new
firmware to the unit.
Remove the serial cable from the unit after setup.

TECHNICAL SPECIFICATIONS
Housing
LED indicators

Black powder coated Aluminum 147 x 90 x 26 mm
POWER
IN USE
NETWORK
SIGNAL STRENGTH

Connectors

PC connection:
LINE connectors:
POWER connection:

Set-up

Set-up data is stored in non-volatile memory.
Setup can be done by using a telephone or PC.

Compatibility
Required voltage
Current consumption

9 way D-Type female
RJ11
2.1 mm DC socket

Compatible with most PABX’s
10 VDC to 16 VDC
300 mA

DOC. NO: SS-10 3G-14 (Rev. 01)

Page 20 of 20



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 20
Producer                        : GPL Ghostscript 8.64
Create Date                     : 2012:05:18 15:16:27+02:00
Modify Date                     : 2012:05:18 15:16:27+02:00
Title                           : Microsoft Word - SS-10 3G Telkom User Manual.doc
Creator                         : PScript5.dll Version 5.2
Author                          : user
EXIF Metadata provided by EXIF.tools

Navigation menu