STS 5000 DATA SHEET ISA
User Manual: STS-5000-DATA-SHEET-ISA-
Open the PDF directly: View PDF .
Page Count: 28
Download | |
Open PDF In Browser | View PDF |
Mul func on substa on maintenance & commissioning test system for current, voltage and power transformers. Capacitance/Tan Delta diagnos c system with the op onal module TD 5000. • Fully automatic • Tan Delta test on rotative machines (generators and motors) • Primary injection testing capabilities: up to 800 A or up to 7000 A, with the optional module BUX • PADS - Power Apparatus Diagnostic Software for automatic testing, assessment and report • Variable output frequency: 15 - 500 Hz • IEC 61850-9-2 communication protocol • Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV) • USB interface and Ethernet interface for PC connection • Compact and lightweight • 2000 V AC high-pot test • Patented technology for capacitance and Tan Delta measurement. • Local control by large graphic display BUX 2000 BUX 3000 BUX 5000 HIGH CURRENT BOOSTERS 20A DC BOOSTER FOR WINDING RESISTANCE TEST STDE POWER TRANSFORMER DEMAGNETIZER STCS SWITCH MODULE Multifunction Substation Maintenance & Commissioning Test Equipment A P P L I C A T I O N The following table lists the tests that can be performed on CTs, VTs, PTs and ground grid. N. TEST 1 2 CT CT 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CT CT CT CT CT CT CT CT VT VT VT VT VT VT TEST DESCRIPTION N. TEST Ratio, Voltage mode Ratio, polarity and burden with high AC current Burden, secondary side; ALF/ISF Excitation curve Winding or burden resistance Voltage withstand Remote polarity check Rogowski coil transformers Low power transformers Tan Delta measurements Ratio; polarity Burden, secondary side Ratio, electronic transformers Voltage withstand Remote polarity check Tan Delta measurements 17 18 19 PT PT PT 20 21 22 23 24 25 26 27 28 29 TEST DESCRIPTION Ratio per TAP Vector group Static and dynamic resistance of Tap Changer contacts PT No-load current PT Short-circuit impedance PT Tan Delta measurements CB High DC current micro-Ohmmeter test CB Tan Delta measurements CB, RELAY Current threshold and timing R Ground resistance and resistivity R Step and touch voltages L Measurement of line impedance and of the related parameters Capacitor Measurement of the capacitance Banks Tests are performed in accordance with the following IEC standards: IEC61869-2; IEC61869-3; EN 60044-1; EN 60044-2; EN 60044-5; EN 60044-7; EN 60044-8; EN 60076-1, and also in accordance with ANSI/IEEE C57.13.1. and C57,12-90. Resistance tests are performed according to the following standards: EN50522, EN61936-1, IEEE802000, IEEE 81-1983, DIN VDE 0101 and CENELEC HD637 s1. LEGENDA: RCTD COMPENSATING REACTOR TD 5000 CAPACITANCE AND TAN DELTA MEASUREMENT SYSTEM POWER TRANSFORMER TESTING GROUND GRID TESTING CAP CAL CALIBRATOR MODULE CURRENT AND VOLTAGE TRANSFORMER TESTING SFRA 5000 SWEEP FRENQUENCY RESPONSE ANALYZER LINE IMPEDANCE TESTING STOIL CELL ELECTRIC MOTOR TESTING STLG MODULE FOR GROUND TESTING AND LINE IMPEDANCE MEASUREMENT STSG SAFETY GROUNDING MODULE POWER GENERATOR TESTING The following op onal modules enhance the STS 5000 features. • The high voltage (HV) generator TD 5000 performs the measurement of the tan Delta, capacitance and power factor of any device, at the frequency of the mains or in a wide frequency range. • The circuit switch op on STCS performs the automa c measurment of PT’s turn ra o, of winding resistance and also tes ng the opera on of the Load or no-Load Tap Changer. • The extremely high current BUX 5000, BUX 3000 and BUX 2000 op ons perform high current tests, with currents up to 7000 A. • The STLG module allows performing high current grid resistance and overhead lines tests. trolley can also be supplied upon request. IEC 61850-9-2 Sampled Values STS 5000 has the facility to test CT, VT, both conven onal and non conven onal, Merging Unit ( MU ) using the IEC 61850-9-2 (SV ) protocol. The STS 5000 generates current or voltage signal and injects these quan es into the CT or VT under test. The STS 5000 then reads the data from the network ( Sample Values ) in order to perform a variety of different tests. . Possibility to test CT ra o and polarity check up to 800 A, 2000 A ( with BUX 2000 ), 3000 A ( with BUX 3000) or 5000 A / 7000 A (with BUX 5000) . Possibility to test VT ra o and polarity up to 2 kV . Test of MU. The STS family includes 4 models: STS 5000, STS 4000, STS 3000 light and TDX 5000. STS 4000 is not equipped with: AC and DC high current outputs.TDX 5000 is not equipped with: AC and DC high current outputs, AC and DC high and low voltage outputs, and current and voltage meters. STS 5000 and STS 4000 can be connected to the Tan Delta module TD 5000; STS 5000 and 4000 can be also connected to the very high current module BUX 5000, BUX 3000 and BUX 2000. STS 5000 includes a six-outputs generator: high AC current; low AC current; high DC current; low DC current; high AC voltage; low AC voltage. In the local control mode, the selected output is adjustable and metered on the large, graphic LCD display. With the control knob and the LCD display, it is possible to enter the MENU mode, that allows to set many func ons, that make STS 5000 a very powerful tes ng device, with manual and automa c tes ng capabilies, and with the possibility to transfer test results to a PC via ETHERNET or Pen Drive. The TDMS so ware, which comes with the test set, allows to download, display and analyse test results obtained in local mode. Remote maintenance and diagnos c of the instrument is available via Ethernet. TDMS operates with all Windows® versions. The ease of opera on has been the first goal of STS 5000. This is why the LCD display is so large and the dialogue in MENU mode is made easy. Connec on diagrams are available accordingly with the test window. STS 5000 includes three measurement inputs: . DC voltage (10 V DC). . AC voltage: .. High range (300 V AC) - .. Low range (3 V AC) . Current (10 A AC or DC). All these inputs are independent among them and allow the measurement of CT or VT outputs or of another source. In addi on, a digital input (up to 300 V) is available: it can measure the ming of a wet or dry contact. The instrument is housed in a transportable aluminium box, which is provided with removable cover and handles for ease of transporta on. A transport TDMS, Test & Data Management Software, is a powerful software package providing data management for acceptance and maintenance testing activities. Electrical apparatus data and test results are saved in the TDMS database for historical results analysis. The TDMS database organizes test data and results for the majority of electrical apparatus tested with ISA test sets and related software. TDMS - Test & Data Management Software PADS - Power Apparatus Diagnostic Software PADS - Power Apparatus Diagnostic Software is a powerful software application, included in TDMS software, that optionally allows the remote control of the STS family: STS 5000, STS 4000, TDX 5000. The software performs various tasks, such as: . Control STS and TD remotely from PC . Create test plan . Download stored test results via Ethernet cable . Create and customize test reports . Print test results This program runs under Windows© environment. Note: Windows is trademark of Microsoft Corporation. STS 5000 - FRONT PANEL Display Keyboard Safety Key Digital input Current input DC voltage input Func on keys Ac ve output AC voltage input V/I Output Power ON/OFF Multifunction function knob Start/Stop External booster output STS 5000 - SIDE PANELS High-current output Remote start Safety warnings Emergency push-bu on External devices input Interfaces High-voltage output TEST PLAN EDITOR is an innova ve and advanced so ware module allowing the operator to define and plan a sequence of tests. The operator defines the desired sequence of tests and sets the parameters of each test. TEST PLAN EDITOR creates a sequence of tests to be performed automa cally. This feature is available for the test of current, voltage and power transformers. It is also possibile to create a test sequence for primary and secondary injec on. Test plans can be saved or recalled, like test results. Up to 64 setngs can be stored and recalled. Se ngs are permanently stored in the memory and new se ngs can be wri en to the same address a er confirma on. During the test, test results can be stored in the memory. At the end of test, se ngs and test results can be transmi ed to a PC provided with TDMS. The so ware allows saving, expor ng and analysing test results. EXAMPLES OF TEST PLAN EDITOR FOR CT TESTS Nominal values window: from these nominal data, the program computes the nominal saturation knee. Tests header window: test reference data. Tolerances window allows se ng the tolerances for each of the available tests. Test selection window: it allows selec ng the test to be performed. At the end of the programming, star ng the first test will execute the complete sequence. During the test, test results are stored in the memory. The test set minimizes the test dura on, in order to avoid over-hea ng the components. The same feature is available when controlling the test set via PC by PADS. • CT RATIO AND POLARITY VOLTAGE METHOD The ratio measurement is performed applying high-voltage AC to the CT secondary and measuring the CT primary voltage. Input parameters are: the nominal primary and secondary current, from which the program computes the nominal ratio, the voltage range, the nominal test voltage and the test frequency. The display shows: • The voltage output, the secondary voltage and the current during the test • Actual ratio and ratio error • Phase shift and polarity. • CT RATIO, POLARITY AND BURDEN CURRENT METHOD The ratio measurement is performed applying high current to the CT primary and measuring the CT secondary current. The burden can be by-passed or left in series for the measurement. In this instance, the voltage drop is measured. The secondary current can be measured by a clamp. Input parameters are: the nominal primary and secondary current, from which the program computes the nominal ratio and the nominal test current. The display shows: • The actual primary current • The corresponding secondary current • The value of the secondary current with the nominal primary current • Actual ratio and ratio error • Phase shift and polarity. When the burden is tested, the following parameters are displayed: • The voltage drop across the burden • For the burden: VA rating at the nominal current, angle and power factor. • CT BURDEN SECONDARY SIDE The burden measurement is performed applying low AC current to the CT burden and measuring the voltage drop. Input parameters are: the nominal secondary current and the nominal test current. The display shows: • The actual current output • The voltage drop across the burden • For the burden: VA rating at the nominal current, angle and power factor • The actual ALF/ISF. • CT EXCITATION CURVE The excitation curve is tested connecting the high AC voltage to the CT secondary, ramping the voltage and measuring at the meantime the output current and voltage. Input parameters are taken from the CT nominal value window. Other inputs are: maximum test voltage, maximum current and test frequency. The test set controls the output voltage and current during the test and stops as the knee is recognized. The display shows: • The characteristic curve • The actual voltage knee and the error with respect to the nominal • The actual current error at knee. • WINDING RESISTANCE The resistance (not impedance) is measured connecting the low DC current source to the winding or burden, and measuring the test current and the voltage drop. Input parameters are: the nominal resistance, the connected output, the test current and the resistance limits. It is also possible to compensate the test temperature. The test set controls the output current and voltage during the test, and stops as the test current is reached. The display shows: • The test current • The voltage drop • The measured resistance and the compensated resistance • The test duration and the current deviation when the measurement was achieved. • VOLTAGE WITHSTAND The test is performed connecting the high AC voltage source between the CT secondary cabling and the ground. Input parameters are: maximum test current (with automatic switchoff), test time, output range, test voltage, test frequency. The display shows: • During the HV ramping, the test voltage and current • As the test is completed, the maximum current, the total elapsed time and the isolation impedance. • REMOTE POLARITY CHECK The test is performed generating a special AC current waveform on the primary side and measuring the secondary current drop, with the optional PLCK polarity checker. Input parameters are: the test current, the time interval and the test result (Pass/Fail). The display shows the test current and records the test result of the different points. • ROGOWSKI COIL The test is performed connecting the high AC current source to the primary side, and connecting the CT secondary side to the low-voltage measurement. Input parameters are: the nominal primary current and the nominal secondary voltage, from which the program computes the nominal ratio, the current range, the test current and the test frequency. The display shows: • The range current and the test current • The actual test current, the secondary voltage and the value of the primary current with the nominal secondary voltage • Actual ratio and ratio error • Phase shift and polarity. • LOW POWER The test is performed connecting the high AC current source to the primary side and connecting the CT secondary side to the low-voltage measurement. Input parameters are: the nominal primary current and the nominal secondary voltage, from which the program computes the nominal ratio, the current range, the test current and the test frequency. The display shows: • The range current and the test current • The actual test current, the secondary voltage and the value of the primary current with the nominal secondary voltage • Actual ratio and ratio error • Phase shift and polarity. • POWER FACTOR, CAPACITANCE AND TAN DELTA with TD 5000 optional module The test is performed using the TD 5000 optional module, and then connecting the high AC voltage source to test target. Input parameters are: Winding, test voltage and frequency, test mode, and the nominal capacitance, PF, DF. The display shows the following data: • Test voltage, current and frequency • Capacitance, Tan Delta and power factor • Power data: active, reactive and apparent • Impedance: module, argument and components. • VT RATIO AND POLARITY The ratio measurement is performed applying high voltage to the VT primary and measuring the VT secondary voltage. Input parameters are: the nominal primary and secondary voltage, from which the program computes the nominal ratio, type of connection (Y or Delta), the HV range, the nominal test voltage and frequency and the selected voltage meter. The display shows: • The actual test voltage • The secondary voltage • The value of the secondary voltage with the nominal primary voltage • Actual ratio and ratio error • Phase shift and polarity. • VT BURDEN The burden measurement is performed applying low AC voltage to the VT burden and measuring the corresponding current. Input parameters are: the nominal secondary voltage, the voltage range, the test voltage and frequency. The display shows: • The actual voltage output • The output current • For the burden: VA rating at the nominal voltage, angle and power factor. • RATIO OF ELECTRONIC TRANSFORMER The ratio measurement is performed applying high voltage to the VT primary, and measuring the low-level VT secondary voltage. Input parameters are: the nominal primary and secondary voltage, from which the program computes the nominal ratio, type of connection (Y or Delta), the HV range, the nominal test voltage and frequency. The display shows: • The actual test voltage • The secondary voltage • The value of the secondary voltage with the nominal primary voltage • Actual ratio and ratio error • Phase shift and polarity. • VOLTAGE WITHSTAND The test is performed connecting the high AC voltage between the VT secondary cabling and the ground. Input parameters are: maximum test current (with automatic switchoff), test time, output range, test voltage and test frequency. The display shows: • During the HV ramping, the test voltage and current • As the test is completed, the maximum current, the total elapsed time and the isolation impedance. • REMOTE POLARITY CHECK The test is performed connecting the high AC voltage source to the primary side and measuring the secondary voltage, with the optional PLCK polarity sensor. Input parameters are: the test current, the time interval and the test result (Pass/Fail). The display shows the test current and records the test result of the different points. • POWER FACTOR, CAPACITANCE AND TAN DELTA with TD 5000 optional module The test is performed using the TD 5000 optional module and then connecting the high AC voltage source to the test target. Input parameters are: Winding, test voltage and frequency, test mode and the nominal capacitance, PF, DF. The display shows the following data: • Test voltage, current and frequency • Capacitance, Tan Delta and power factor • Power data: active, reactive and apparent • Impedance: module, argument and components. • RATIO PER TAP The ratio measurement is performed applying high voltage to the PT primary and measuring the PT secondary voltage for each tap. If the STCS option is available, connection is performed via the option and the test is completely automatic. Input parameters are: the nominal primary and secondary voltage, from which the program computes the nominal ratio, type of connection (Y or Delta), the type of Tap changer, the HV range, the nominal test voltage and frequency and the selected voltage meter. The display shows: • The test current and angle • The test voltage, primary and secondary • Actual ratio and ratio error • Phase shift and polarity • VECTOR GROUP The test is performed connecting the high AC voltage source between PT primary windings, while the others are short-circuited. The test is composed by two measures of secondary windings voltage and phase shift. If the STCS option is available, connection is performed via the option and the test is completely automatic. Input parameters are: the test voltage and frequency, the nominal turn ratio, the presence of neutral winding. The display shows: • Test voltage and frequency • Test connections • Phase displacement and connection • STATIC AND DYNAMIC WINDING RESISTANCE AND TAP CHANGER TEST The test is performed applying low DC current to the PT primary plus Tap Changer and measuring the voltage drop. The tester measures the resistance peak during the switch and the resistance after the selection. If the STCS option is available, the connection is performed via the option and the test is completely automatic. Input parameters are: the tap number, the type of Tap changer, the current range, the test current, the nominal resistance and the resistance limits. It is also possible to compensate the test temperature. The test set controls the output current during the test and issues the Tap Change command. The display shows: • The test current • The tap number • For the static resistance: the test voltage and resistance, also compensated • For the dynamic resistance: the measured values are the Ripple and the Slope and a graphical representation of current and resistance profiles. The dynamic resistance measurement is performed also without the STCS option. • NO-LOAD CURRENT The test is performed using TD 5000 optional module or using the internal high voltage source up to 2kV and then connecting the high AC voltage source to the test target. Input parameters are: the tap number, the type of Tap changer, the test voltage and the frequency. The test set applies the high voltage and measures the output current during the test. The display shows: • The test voltage • The current and the phase shift • The power losses • The reactance. • SHORT-CIRCUIT IMPEDANCE The test is performed applying low AC current to the winding under test, while other windings are short-circuited and measuring the associated voltage and phase shift. Input parameters are: the test current and frequency, the type of winding and the phase under test. It is also possible to compensate the test temperature. The test set measures the output voltage and computes the related parameters. The display shows: • Phase shift; the power loss; the R, X, Z and inductance of the transformer • Short-circuit impedance in Per Unit. • POWER FACTOR, CAPACITANCE AND TAN DELTA with TD 5000 optional module The test is performed using the TD 5000 optional module and then connecting the high AC voltage source to test target. Input parameters are: Winding, test voltage and frequency, test mode and the nominal capacitance, PF, DF. The display shows the following data: • Test voltage, current and frequency • Capacitance, Tan Delta and power factor • Power data: active, reactive and apparent • Impedance: module, argument and components. • CB; PRIMARY AND SECONDARY RELAY TESTS The selection allows to inject the test parameter and measuring the relay threshold and trip delay of a breaker or of a relay. It is also possible to measure external voltages and currents. With the option BUX 5000 it is possible to perform high current tests, up to 7000 A. Input parameters are: current range, output current, output voltage and frequency. It is possible to enable the time measurement on the digital input or on the fall of the applied current (breaker tests) and to set the type of digital input (wet or dry). The display shows the following data: • Test current or test voltage• Trip time • Closing time • External voltage and current measurements. • CONTACT RESISTANCE The contact resistance test is performed using the high DC current output. The test set measures the contact resistance down to the µOhm range. With the same selection it is also possible to measure higher resistances. Input parameters are: current output range, test current and resistance limits. The display shows: • DC current • DC voltage • Resistance. • POWER FACTOR, CAPACITANCE AND TAN DELTA with TD 5000 optional module The test is performed using the TD 5000 optional module and then connecting the high AC voltage source to test target. Input parameters are: Winding, test voltage and frequency, test mode and the nominal capacitance, PF, DF. The display shows the following data: • Test voltage, current and frequency • Capacitance, Tan Delta and power factor • Power data: active, reactive and apparent • Impedance: module, argument and components. • SOIL RESISTIVITY The test of soil resistivity is performed applying AC voltage to the current spikes and measuring the injected current and the voltage across the voltage spikes. For the resistivity test, input parameters are: voltage range, test current, test frequency. The display shows: location, probes distance, output voltage, voltage between probes, output current, corresponding resistivity, evaluation. • GROUND GRID RESISTANCE The test of ground grid resistance is performed applying current between the ground grid and the auxiliary ground spikes. With the STLG option the test is performed using an overhead line to connect to the remote ground. For the resistance test, input parameters are: output voltage range, test current, test frequency. The display shows: test probe distance, output voltage, test probe voltage, output current, phase shift, earth resistance, evaluation. • STEP AND TOUCH VOLTAGES The step and touch voltages test is performed applying current between the ground grid and the auxiliary ground spikes and measuring the step or touch voltage with the test probes. With the STLG option, the current generation is performed using an overhead line to connect to the remote ground. Thanks to the STLG option, higher test currents can be achieved. Input parameters are: substation fault current, fault clearance time, parallel resistance on the test probes. Other selections are: output voltage range, test current, test frequency. Last, the operator selects the measurement mode: manual or on STS and the reference standard. The display shows the following data: test current, location description, location coordinates, measured voltage, voltage in case of actual fault. • LINE IMPEDANCE The line impedance test has the purpose of verifying the computed value of the Earth coefficient KL for the HV overhead lines. This is a critical parameter for the setting of a distance relay: a wrong value causes the false fault location. The test is performed injecting current into the lines, in many modes: line to line, three lines to ground, with or without current in parallel lines. With the STLG option, the current generation can be performed even in presence of induced voltages. The device measures the injected current and the corresponding voltage drop and phase shift. Input parameters are: maximum test voltage and test current. Other parameters are the line material and the test temperature. Tests are performed at frequencies ± 5 Hz with respect to the line frequency, in order to remove the noise. To the left, the display shows the measured and computed values of the impedances; to the right, the computed corrective factors. • PADS SOFTWARE The PADS software is a powerful application, included in the TDMS software, which provides connectivity to the instruments of the STS family. The software performs various tasks, such as: • Edit and upload to the instrument the test headers • Create and modify plans containing one or more tests • Optionally remote control of the execution of test plans (start, interruption, results assessment) • Download and save results of tests previously performed by the instrument • Open and save results on the PC • Print test results. GENERATOR OUTPUT The internal generator has six outputs: High AC current, High DC current, Low AC current, Low DC current, High AC voltage, Low AC voltage. Output adjustment is automa cally performed once the test has been set. The generated frequency can be userdefined or synchronized to the supply frequency (with op onal power line synchronizer).The following specifica on applies to the separate use of these outputs. High AC current output - supply 230 V AC * /** CURRENT OUTPUT A AC MAX POWER VA 800 600 400 300 200 4800 3780 2560 1940 1300 MAX TEST DURATION s 25 200 500 15 min > 2 hours FREQUENCY Hz 15 to 500 15 to 500 15 to 500 15 to 500 15 to 500 NOTE: the output amplitude may decrease for frequency below 50 Hz and above 60 Hz. . Connec on: two high-current safety sockets, with safety protec on . Measurement accuracy: < 0.1 % of the reading,< 0.1% of the range . Phase error: < 0.1° High DC current output * /** CURRENT OUTPUT A DC 400 300 200 100 MAX POWER W 2600 1950 1300 630 MAX TEST DURATION s 140 3 min > 2 hours >> 2 hours 2000 2000 2000 1.25 1 0.5 2500 2000 1000 60 15 to 500 130 15 to 500 > 2 hours 15 to 500 1000 1000 1000 2.5 2 1 2500 2000 1000 60 15 to 500 130 15 to 500 > 2 hours 15 to 500 500 500 500 5 4 2 2500 2000 1000 60 15 to 500 130 15 to 500 > 2 hours 15 to 500 . Measurement accuracy: < 0.05% of the reading, < 0.05% of the range. . Phase error: 0.1° (2000 V range). The test set measures the current generated by the HV output. CURRENT RANGE A 5 0.5 0.05 ACCURACY PHASE ERROR PHASE < 0.2% reading < 0.05% range < 0.1° ERROR < 0.05% reading < 0.05% range < 0.1° < 0.1% reading < 0.1% range < 0.2° Notes: . Accuracy values refer to the internal measurements of the outputs. . Accuracies are typical values. . Output power is reduced with the supply of 110 V. . The output amplitude may decrease for frequency below 50 Hz and above 200 Hz. Low AC current output ** . Maximum output current: 6 A or 3 A AC. . Maximum output voltage: 70 V AC or 140 V AC. . Maximum output power: 360 VA. . Connec on: two safety 4 mm banana sockets. . Frequency range: 15 - 500 Hz. . Connec on: two high-current sockets, with safety protec on. . Accuracy: < 0.2% of the reading, < 0.05% of the range. Low DC current output ** . Maximum output current: 6 A DC. . Maximum output voltage: 65 V DC. . Maximum output power: 360 W. . Connec on: two safety 4 mm banana sockets. High AC Voltage output ** The high AC voltage output is isolated by a HV switch inside the test set. This switch is closed only when the operator selects a high-voltage test, a er the enable key is turned ON and a er the START bu on is pressed. Three voltage ranges are available. Low AC Voltage output ** . Voltage range: 140 or 70 V AC. . Output power: 420 VA. . Frequency range: 15 - 500 Hz. . Connec on: two safety 4 mm banana sockets. Output frequency . AC output frequency range: 15 to 500 Hz. . Frequency resolu on: 10 mHz. . Output connec on: two HV safety sockets. * Output not available on the STS 4000 model. * * Output not available on the STS 3000 light and TDX 5000 models. MEASURING INPUTS Current and Voltage It is possible to meter the current and the voltage of an external generator. Three metering groups are available: • AC or DC current, up to 10 A. • AC voltage, with two connec ons: o High range, up to 300 V AC. o Low range, up to 3 V AC. • DC voltage, up to 10 V DC. The selected input is shown in the front panel by a LED. Resolu on and accuracy INPUT RANGE DC VOLTAGE 1 A; 10 A 1 A; 10 A 300 mV; 3 V; 30 V; 300 V 30 mV 300 mV 3V 10 mV 100 mV 1 V; 10 V <%0.05 <%0.05 <%0.03 <% 0.08 <%0.15 <%0.05 <%0.05 <%0.05 <%0.1 <%0.25 <%0.08 <%0.08 <%0.03 <%0.08 <%0.05 <%0.15 <%0.05 <%0.10 <%0.03 <%0.08 Binary Input - Timer The test set allows tes ng protec on relays. In this mode of opera on, the test current or voltage can be ramped or stepped. As the output changes, a mer is started; the mer stops as the Digital input senses that the relay has tripped or the output cut is cut. Characteris cs of the Digital input: • The input may be selected as Normal Open, Normal Closed. • The mer can start from an analog input ( current or voltage). • The mer can start and stop at the changing of the digital input, both dry or wet contact. • Type of input: either dry or under voltage. Maximum input: 300 V AC or DC. • Voltage thresholds: 5 V, 24 V, 48 V or > 80 V. • Timer resolu on: 1 ms. • Imput impedance ≥ 1M Ω Phase angle The test set measures the phase angle between the two AC selected parameters which are used during the test. MEASUREMENT RANGE PHASE 0 - 360 RATIO BURDEN RESISTANCE POLARITY KNEE POINT For the CT, VT and PT ra o measurement, the following applies. • Range: 0 to 9999 • Resolu on: 1 • Accuracy: <%0.15% of the reading <% 0.15% of the range. ACCURACY reading & range AC CURRENT DC CURRENT Star ng from the internal and external measurements, the test set computes the following parameters: RESOLUTION ACCURACY 0.01° < 0.1° Resistance measurement For the resistance test, the following applies: SOURCE RANGE HIGH DC CURRENT 400 A LOW DC CURRENT 6A DC V METER 10 µOhm to 10 mOhm 100 mOhm to 10 Ohm 100 Ohm to 20 kOhm ACCURACY < 0.7% < 0.5% < 0.3% < 0.2% < 0.6% < 0.5% . Accuracies are typical values. COLOUR DISPLAY The large graphic display has the following characteristics: • Pixels: 640 x 480, coloured. • LCD type: TFT. • View area: 132 x 99 mm. • Backlight. OTHER CHARACTERISTICS Communication interfaces • ETHERNET for the PC connection. • USB port for the USB key. Interfaces to external modules: • Commands to TD 5000 and STCS. • Alarms to a flashing light. • Remote start input. Mains supply 100-230 V ± 15%; 48-62 Hz. Maximum supply current: 16 A. Dimensions: 450 (W) x 400 (H) x 230 (D) mm. Weight: 29 kg APPLICABLE STANDARDS The test set conforms to the EEC directives regarding Electromagnetic Compatibility and Low-Voltage instruments. A) Electromagnetic Compatibility: Directive no. 2004/108/EC. Applicable Standard : EN61326-1:2006 B) Low Voltage Directive: Directive n. 2006/95/EC. Applicable standards: CEI EN 61010-1:2010. In particular: . Input/output protection: IP 2X - IEC69529; IP 4X for HV output. . Operating temperature: -10° to 55 °C; storage: -20 °C to 70 °C. . Relative humidity: 5-95% without condensing. CONNECTION CABLES . . . . . . . . . . . . . . . . One mains supply cable, 2 m long. One grounding cable, 6 m long. One interface cable for the USB port. One ETHERNET interface cable. One USB pen drive. Two high-current connection cables, 70 sq. mm, 6 m long (9 m long optionally), for tests up to 800 A. Two high-voltage connection cables, 6 m long (10 m long optionally), 5 kV, with earth screen. Six connection cables (three red and three black,) 2.5 sq. mm, 6 m long (10 m long optionally), for the connection of: DC current output, low AC voltage output and digital input. Four clamps to connect low voltage or low current or measurements, two red and two black, with a short cable terminating with a banana socket. Six “Kelvin” clamps, with two sockets each, to connect generator and measurement. One cable for the 3 V measurement connection, shielded, 6 m long (10 m long optionally). One cable for the 10 V measurement connection, shielded, 2.5 sq. mm, 6 m long (10 m long optionally). Four crocodiles for measurements connections (two red and two black). One short cable, red, for the current measurement. One connection cables transport case. Extra long connection cables for EHV equipment (> 700 kV) can be supplied optionally. TRANSPORT CASE The transit case allows delivering STS 5000 with no concern about shocks up to a fall of 1 m. This case is supplied with handles and wheels. STSA AND STSA 3V SURGE ARRESTERS These devices apply to all STS models. They limit voltage surges generated at 10 V or 3 V voltage measurement inputs respectively if, during the winding resistance test, the circuit is erroneously opened. They include a surge arrester plus two fuses. BUX 2000 BUX 3000 BUX 5000 HIGH CURRENT BOOSTER The three op onal current boosters BUX 2000, BUX 3000 and BUX 5000 allow performing tests up to 2000A, 3000 A or 5000 A. The op on is made of a module, which incorporates: • A power transformer, which generates a low-voltage, high-current output. • A metering CT, which measures the output current, and sends the metering to STS 5000. Op on features: BUX 2000 TEST CURRENT A OUTPUT POWER VA TEST DURATION s 500 1000 2000 700 1500 5000 INFINITE 60 25 BUX 3000 TEST CURRENT A 1000 2000 3000 OUTPUT POWER TEST DURATION VA s 900 2400 4800 INFINITE 300 60 BUX 5000 TEST CURRENT A 1000 2000 3000 4000 5000 OUTPUT POWER TEST DURATION VA s 700 1500 2700 4200 5500 INFINITE 300 30 20 10 • Frequency: 15 Hz - 500 Hz.* • Weight: BUX 2000 18 kg, BUX 3000 15 kg, BUX 5000 19 kg without current cables and clamps. • Dimensions for models BUX 2000 and BUX 3000: external diameter 190 mm; height 120 mm. STSA • Dimensions for model BUX 5000: external diameter 200 mm; height 170 mm. All high current boosters are supplied with: . 4 cables, 95 sq. mm, 2 m long, with 2 high current clamps for BUX 2000 . high current cable, made of 4 cables, 95 sq. mm, 1.2 m long, with 2 high current clamps for BUX 3000 . 12 cables, 95 sq. mm, 0.8 m long, with 4 high current clamps for BUX 5000 . one power supply cable , 20 m long . one measurement cable, 20 m long, with the output current measurement. . In addi on, the op on is provided with 2 metering cables for the connec on of the CT secondary. 20A DC BOOSTER WINDING RESISTANCE TEST The 20A DC STCS booster allows to perform resistance tests on a PT with a current up to 20 A DC, instead of the 6 A DC provided by STS 5000 or STS 4000. The option applies to STS 5000 and STS 4000 and must be connected to STCS, which controls it. Booster characteristics: . Maximum output current: 20 A DC . Maximum power on output sockets: 400 W . Current output switch: controlled by STCS . Current output amplitude: controlled by STS 5000 or STS 4000. The option comes complete with all the necessary connection cables. * The output amplitude may decrease for frequency below 50 Hz and above 60 Hz. STCS SWITCH MODULE The external module STCS allows performing automatically the following PT tests: ratio per tap; winding resistance; OLTC dynamic test. The connection to the transformer under test, to STS and to the measurement taps is performed just once; then, all transformer tests are performed without interruptions. 20 A DC BOOSTER STDE POWER TRANSFORMER DEMAGNETIZER STCS This option applies to STS 5000 and STS 4000. Device characteristics: . Inputs from STS: 300 V AC or 6 A DC. . Tap Changer Up and Down: 240 V AC or 110 V DC. . Outputs to STS measurements: 300 V AC or DC and 10 V DC. The option comes complete with the following connection cables (which can also be ordered separately): . 10 Coaxial cables, for low voltage connections. . 2 Cables, 2 m long, for the connection of the STS HV output to the STCS input. . 6 Cables, 2 m long, for low voltage connections. . 1 connection cable to the EXT. DEVICES connector of STS. . 6 converters, from banana to terminator. . 8 “Kelvin” type clamps, for the connection of the PT generator and meter. . 1 Ground cable, 6 m long. . 2 Transit cases. This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard. Device characteristics. . Constant current, voltage limited generator . Maximum test current: 7 A DC . Maximum test voltage: 70 V DC . Output current stability: better than 0.5% of the rated value . Automatic current direction reversal. The option is connected to STS via the control connector, which supplies its circuits and issues the generation commands. The power is taken from the STS low-power DC current generator. . Housing: plastic case with handle. STDE STLG MODULE FOR GROUND TESTING AND LINE IMPEDANCE MEASUREMENT The option allows performing both the measurement of: soil resistivity, ground grid resistance, step and touch tests and overhead lines zero sequence and mutual coupling coefficients. This option applies to STS 5000 and 4000 models. STLG is a high power transformer, which increases the output current. A high current switch allows selecting the desired current range. A voltage meter displays the generated voltage. STSG SAFETY GROUNDING MODULE During tests, STLG is connected to the overhead line to be tested. The purpose of the STSG optional device is to protect the operator against possible high voltage spikes. STSG incorporates three voltage suppressors and one high current switch, to connect three lines in parallel. This option applies to STS 5000 and 4000 models, in conjunction with STLG. Option characteristics: . Nominal AC spark-over voltage: 1000 V rms . Impulse spark-over voltage: 2000 V peak . Short-circuit proof with 25 kAeff / 100 ms; 36 kAeff / 75 ms . Connection via three cylindrical ball studs 16, 20 or 25 mm diameter. The ball diameter must be specified at order. . Metal aluminum box with handle . Weight: 9.1 kg . Dimensions: 41 x 21 x 13.5 cm . Grounding cable included: 95sq.mm, 2m. GROUND GRID TEST ACCESSORIES KIT STLG The option takes its power from the EXT. BOOSTER connector of STS. Output current and voltage are metered and sent back to STS measuring inputs; a third output allows STS to know the selected range. Device characteristics are the following: . Input: from STS 5000, via the booster connector . Output current ranges: 11, 22, 35, 55, 105 A AC . Output power: 1800 VA steady; 5200 VA peak for 10 s . High current range selector switch . Analogue output voltage meter. Meter range: 600 V AC . Outputs to STS 5000: selected current output range, output current and output voltage. All necessary connection cables are included in the option. Current clamp provided: 400 A range. Housing: black plastic case, with handles. Weight: 25 kg. Dimensions: 23 x 33 x 44 cm. STSG This option applies to STS 5000 and 4000 models. The option is the kit of connection cables, auxiliary spikes and other accessories that allows connecting STS or STLG to the testing devices and performing all types of tests. The kit includes: . Four earth spikes for the soil resistivity test and for the earth resistance test. . Two auxiliary earth spikes, for tests in small sites. . Three cables, wound on wheels, 200 m long. . One mains synchronizer device, to synchronize the STS generation to the mains. . Two test probes for the step and touch test. . One voltage meter, digital, type true RMS, for the earth resistance and step and touch tests. . One resistor box for the step and touch test. This kit is not supplied with Line Impedance. GROUND GRID TEST ACCESSORIES KIT LINE IMPEDANCE KIT CURRENT CLAMP The kit is made of STLG - Line and Grid module and STSG - safety grounding module, without the line and grid accessories. The current clamp allows to avoid the opening of the secondary current circuit when performing the primary test of CT burden. The clamp ra o is 1000/1; maximum primary current 100 A and maximum cable diameter 12 mm. PLCK POLARITY CHECKER MODULE WARNING STROBE LIGHT The warning strobe light alerts when the test is completed, or when there are alarms. The light is self-powered, and turns on (flashes) upon the test set command. A siren is also included. TRANSPORT CASES PLCK POLARITY CHECKER Checking the correct connection of CT’s and VT’s to protection relays is a problem because relays can be hundreds of meters away from the transformer. PLCK easilys solves the issue. When this test is started, STS 5000 generates a special, not sinusoidal waveform, which is injected into the connection cables. The polarity check is easily performed by connecting it at the relay site. PLCK hast wo lights: green and red. The green light turns on when the polarity is correct; the red light turns on when the polarity is wrong. HEAVY DUTY TRANSPORT CASE REMOTE SAFETY SWITCH Transport cases for STS 5000, TD 5000 and BUX 3000 are available; all of them allow transporting the device with non concern about shocks or falls up to 1 m. The case is complete with handles and wheels. FOLDABLE TROLLEY The trolley eases the transport of STS 5000, especially when the optional TD 5000 has to be used too. The trolley is designed to host both instruments and also the high-voltage cable for TD 5000. REMOTE SAFETY SWITCH If it is desired to start the test remotely from the test set, the optional switch allows to do it, up to the distance of 20 m, which is the length of the cable provided. FOLDABLE TROLLEY SFRA 5000 ANALYZER SWEEP FREQUENCY RESPONSE SFRA 5000 is a stand alone sweep frequency response analyzer for the high accuracy transformer analysis and integrates the STS and TD 5000 family test sets. The SFRA 5000 offers both high precision and portability in a single package, providing all the accessories required for fast, easy to use, reliable and repeatable measurements. SFRA 5000 is provided with its own embedded software, giving the possibility to the engineer to zoom into a portion of the sweep in order to inspect any differences in the plot in more detail during or after a sweep. OPTIONAL SOFTWARE PADS - power apparatus diagnostic software PADS - Power Apparatus Diagnostic Software is a powerful software application, included in TDMS software, that allow the remote control of the STS family: STS 5000, STS 4000, TDX 5000. These devices allow performing tests of: CTs, VTs, PTs, CBs and almost all other power devices in electrical substation. PADS SOFTWARE SFRA 5000 PADS SOFTWARE Capacitance and Tan Delta diagnos c system for high-voltage apparatus • Optional module for STS 5000 and STS 4000 test set, standard module for STS 3000 light • Tan Delta, capacitance, dissipation factor measurements and for exciting current test The following table lists the tests that can be performed on power transformers and high-voltage apparatus: • Tan Delta (or dissipation factor DF): from 0 to more than 100%. • Capacitance: from 1 pF to 200 µF. • Power factor : from 0 to 100%. • Output voltage from 12 V up to 12 kV GENERAL CHARACTERISTICS • Variable output frequency: 1 - 500 Hz • PADS - Power Apparatus Diagnostic Software for automatic testing, assessment and report • Compact and lightweight • Patented technology The high-voltage generator TD 5000 performs the measurement of the Tan Delta, of the dissipation factor and of the capacitance of a transformer or of a bushing, at the frequency of the mains or in a wide frequency range. The measurement is performed by the module, which is equipped with a patent pending technology. The measurement circuitry incorporates a reference high voltage capacitor, rated 200 pF, with a tan delta better than 0.005%, plus a reference resistor bridge, with accuracy better than 0.01%, and thermal drift less than 1 ppM/°C. The patented circuitry and the variable frequency output make test results immune from external noise. Available test selections: • Ungrounded: UST-A; UST-B; UST A+B; • Grounded: GST; GSTg-A; GSTg-B; GSTg-A+B. TD 5000 is powered and controlled by STS 5000, STS 4000. Type of generator: HV generator with electronic control. Capacitance and Tan Delta diagnostic equipment GENERATOR CHARACTERISTICS MAX VOLTAGE OUTPUT V 12000 12000 12000 CURRENT OUTPUT A 300 mA 125 mA 100 mA MAX OUTPUT DURATION T Max FREQUENCY Hz 240 s > 1 hour steady 1 to 500 1 to 500 1 to 500 Note1: the maximum voltage output may decrease for frequency below 50hz and above 400Hz. Note2: at 10 kV the output (current value and duration) has the same characteristic. Voltage and current output metering accuracy and resolution. INTERNAL MEASURE RESOLUTION 12000 V AC 1V 5 A AC 0.1 mA (@ inputs A or B> 10 mA) <10 mA AC 0.1 µA (@ inputs A or B) TYPICAL ACCURACY GUARANTEED ACCURACY ± % (rdg) ± % (rg) ± % (rdg) ± % (rg) ± 0.2% ± 0.5 V ± 0.2% ± 1 mA ± 0.2% ± 0.1 µA < 0.3% + 1 V < 0.5% < 0.3% + 0.1 µA . Frequency range: 1 to 500 Hz. . Connections: by a double shielded HV connector, two Ground sockets (case and external shield of HV cable), and two measurement sockets (A and B). teed: 0.1% of the value ± 0.005 % (from 45 to 70 Hz, current < 10 mA). . Measurement range 2: from 0 to 100%. Resolution: 5 digits; accuracy, typical: 0.3% of the value ± 0.02 %; guaranteed: 0.5% of the value ± 0.02 %. • Impedance From 1kOhm to 1400 MOhm. Accuracy, typical 0.3% of the value ± 0.1%, guaranteed <0.5% of the value. Resolution: 6 digits. • Power . Measurement ranges: 10 kW, 100 kW, 1 MW. Resolution (6 digits): 0.1 mW; accuracy: <0.5% of the value ± 1 mW. The same ranges and accuracies are applied to reactive and apparent power measurements. • Inductance . Measurement range 1: from 1 H to 10 kH. Resolution (6 digits): 0.1 mH; accuracy, typical: 0.3% of the value ± 0.5 mH; guaranteed: 0.5% of the value. . Measurement range 2: from 100 H to 10 MH. Resolution (6 digits): 1 H; accuracy, typical: 0.3% of the value; guaranteed: <0.5% of the value. • Excitation current . Range 1: 10 mA. Resolution: 0.1 µA; accuracy, typical: 0.2% of the value ± 0.1µA; guaranteed: 0.3% of the value ± 0.1µA. . Range 2: 300 mA. Resolution 1 mA; accuracy, typical: 0.2% of the value ± 1 mA; guaranteed: 0.5% of the value ± 0.5% of the range. Output frequency . AC output frequency range: 1 to 500 Hz. TEST MEASUREMENTS • Capacitance . Measurement range 1: from 1 pF to 5µF. Resolution: 6 digits. Accuracy, typical: ± 0.03% of the value ± 0.1 pF; guaranteed: < 0.1% of the value +1pF (from 45 to 70 Hz). . Measurement range 2: from 5 µF to 200 µF. Resolution: 6 digits. Accuracy, tipical: ±0.1% of the value ±0.1 nF, guaranteed: <0.5% of the value ±1 nF. • Tan Delta or dissipation factor DF . Measurement range 1: from 0 to 10% (capacitive). Resolution: 5 digits; accuracy, typical: 0.05% of the value ± 0.005 %; guaranteed: 0.1% of the value ± 0.005 % (from 45 to 70 Hz, current < 10 mA). . Measurement range 2: from 0 to 100%. Resolution: 5 digits; accuracy, typical: 0.3% of the value ± 0.01 %; guaranteed: 0.5% of the value ± 0.02 %. . Measurement range 3: over 100%. Resolution: 5 digits; accuracy, typical: 0.5% of the value ± 0.03 %; guaranteed: 0.8% of the value ± 0.05 %. • Power factor PF (or cos(φ)) . Measurement range 1: from 0 to 10% (capacitive). Resolution: 5 digits; accuracy, typical: 0.05% of the value ± 0.005 %; guaran- Max interference condi ons at line . Electrosta c: 15 mA rms of the interference current into any lead or cable with no loss of measurement accuracy. Applicable to a maximum ra o of interference current to specimen current 20:1. . Electromagne c: 500 µT, at 50 Hz in any direction. TD 5000 Dimensions: 440 (W) x 345 (H) x 210 (D) mm. Weight: 25 kg. TESTING CABLES The option comes complete with the following connection cables: • 1 yellow-green connection cable, 6 m long, for the ground connections, terminated with terminator on one side, and with a clamp on the other side. • 2 yellow-green connection cables, 1 m long, for the ground connections, terminated with terminators. • 1 yellow-green connection cable, 2 m long, for the ground connections, terminated with terminators. • 1 power cable to the BOOSTERS connector of STS, 1 m long. • 1 power cable to the BOOSTERS connector of STS, 2 m long. • 1 High voltage connection cable, 20 m long, 25 kV, with earth screen, for the connection to the device under test, terminated on the device side with an isolated banana plug, and on the TD 5000 side with two plugs: one for the HV and the other one for the ground. The cable is mounted on a wheel. • 1 clamp, 25 mm opening, with a connector which mates with the HV cable. • 1 bigger clamp, 40 mm opening, with a connector which mates with the HV cable. • 2 shielded connection cables, 20 m long, for the connection to the metering points. Terminated on the TD 5000 side with the metering connector, and on the device side with a banana plug. Cables are mounted on wheels. • 2 clamps, 25 mm opening, terminated with banana sockets, which allow connecting to the metering point. • 2 Kelvin type clamps, 40 mm opening, with banana plugs, which allow connecting to the metering point. • 1 hot collar cable, 1m long, with connector. • 1 signals connection cable to the EXT. DEVICES connector of STS, 1 m long. • 1 signals connection cable to the EXT. DEVICES connector of STS, 2 m long. • 1 connection cables transport case. • Extra long connection cables for EHV equipment (> 700 kV) can be supplied optionally. ductor can be up to 1A for more than 10s. The inductors can be connected in parallel on the load in order to increase the test frequency. It is possible to connect two RCTD in parallel in order to have three or four inductors connected together (2 x 80 H total). CAP CAL CALIBRATOR MODULE Purpose of the calibrator is to check the correctness of TD 5000 measurement. The calibrator includes an extremely high accuracy high voltage capacitor, which comes with a cer ficate issued by ISA lab. CAP CAL STOIL CELL FOR THE HV TEST OF THE DIELECTRIC OIL FOLDABLE TROLLEY The trolley eases the transport of TD 5000 and is designed to host both instruments and also the high-voltage cable. TRANSPORT CASE The transit case allows delivering TD 5000 with no concern about shocks up to a fall of 1 m. RCTD COMPENSATING REACTOR OIL CELL The option allows testing that the oil characteristics of isolation are met and that there is no contamination. The option is made of a suitable glass container with electrodes; the electrodes are connected to the option TD 5000 for the test execution. The test result, displayed by STS 5000, is the oil Tan Delta. Cell characteristics are the followings: • Maximum test voltage: 12 kV • Cell volume: about 1l • Capacitance of the empty cell: 60 pF. RCTD This module is useful for testing Tan Delta in rotating machines with TD 5000 and allows increasing the test current and getting the maximum test voltage with high capacitive burdens. Each RCTD is composed by two inductors with a nominal value of 40H and a steady current of 0.4A. The maximum current on each in- DIGITAL THERMO HYGROMETER A number of tests performed by STS, such as coil resistance, Tan Delta are influenced by temperature and humidity. The option allows measuring these parameters and to input them into the test settings. Meter characteristics: . Temperature range:- 10°C to 60°C. . Temperature measurement accuracy: ± 0.4°C. . Humidity measurement range: 5 % to 95% RH. . Accuracy of humidity measurement: ± 2.5% RH, over the whole range. . Dimensions: 141 x 71 x 27 mm. Weight: 150 g. Capacitance and Tan Delta diagnostic equipment CODE MODULE 10175 39175 18175 STS 5000 - with TDMS software*, standard test cable kit, STSA and heavy duty transport case STS 4000 - with TDMS software*, standard test cable kit, STSA and heavy duty transport case TDX 5000 with TDMS software*, standard test cable kit and heavy duty transport case STS 3000 light - with TD 5000, TDMS software*, standard test cable kit, foldable trolley and heavy duty transport case TD 5000 module for the high-voltage test of Tan Delta for transformers and bushings, supplied with test cables, heavy duty transport case and foldable trolley CODE MODULE CODE 10176P PADS software (primary)- Primary, CTs, VTs test module* PADS software (trasfo)- Power transformer and Tan Delta test module* PADS (full)- Full software suite (includes 10176P & 10176T)* BUX 5000 - External Advanced Booster up to 5000 A supplied with transport case BUX 3000 - External Advanced Booster up to 3000 A supplied with transport case BUX 2000 - External Advanced Booster up to 2000 A supplied with transport case STCS Circuit switch module and with Cable test kit for STCS 20A DC STCS Booster Step & Touch testing kit: . ST-LG Line & ground grid module (100 A booster). . Cables set for STLG . Heavy duty plastic transport case for STLG . ST-SG Safety grounding module . Heavy duty plastic transport case for STSG . Step & touch, earth resistance/resistivity accessories. Line Impedance testing kit: STLG Line & ground grid module (100 A booster). . Cables set for STLG . Heavy duty plastic transport case for STLG . STSG Safety grounding module . Heavy duty plastic transport case for STSG. Stud 20 mm for Step & Touch testing kit Stud 25 mm for Step & Touch testing kit Stud 16 mm for Step & Touch testing kit Earth Resistance and Soil Resistivity Kit 27175 13175 37175 20175 37175 65175 38175 31175 11175 37175 11175 10176T 10176F 63175 50175 56175 12175 22175 32175 81175 84175 72175 73175 74175 19102 40175 41175 42175 43175 44175 47175 48175 16102 90175 15175 14175 16175 17175 18175 19175 51175 52175 57175 MODULE STDE demagnetizer module STOIL Cell for the eletric test of insulating oil of the transformer CAP-CAL Calibration module PLCK - Polarity checker Remote safety switch Warning strobe light Digital thermo hygrometer RCTD - Compensating reactor for TD 5000 with transport case Cable test kit for RCTD Current Clamp 1/1000 Max 100A SFRA 5000, supplied with cables, software and transport case Cable test kit with case for STS 5000 Cable test kit for TD 5000 Optional long cable test kit for STS 5000 Heavy duty plastic transport case for STS 5000 Trolley for STS family test sets and TD 5000 Heavy duty plastic transport case for TD 5000 Heavy duty plastic transport case for BUX 3000 BU2000-STS adaptor Extra long connection cables for EHV equipment *PADS - Power Apparatus Diagnos c So ware is NOT included into basic unit price. It should be expressely ordered. For USA and Germany, only STS 3000 light with TD 5000 and/or TDX 5000 test sets are available. NO. TEST OF TEST DESCRIPTION 1 2 CT CT 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 CT CT CT CT CT CT CT CT VT VT VT VT VT VT PT PT 19 PT Ra o, Voltage mode Ra o, polarity and burden with high AC current Burden secondary side; ALF/ISF Excita on curve Winding or burden resistance Voltage withstand Remote polarity check Rogowski coil transformers Low power transformers Tan(δ) measurements Ra o; polarity Burden, secondary side Ra o, electronic transformers Voltage withstand Remote polarity check Tan(δ) measurements Ra o per TAP Vector Group 20 21 22 23 24 25 26 Sta c and dynamic resistance of Tap Changer contacts PT Excita on current PT Short circuit impedance PT Tan(δ) measurements CB High DC current micro-Ohmmeter test CB Tan(δ) measurements VTCBRELAY Current threshold and ming R Ground resistance and resis vity 27 28 R L 29 Capacitor Measurement of the capacitance Banks STS 5000 STS 4000 TDX 5000 NOT AVAILABLE WITH BUX NOT AVAILABLE NOT AVAILABLE NOT AVAILABLE NOT AVAILABLE NOT AVAILABLE WITH TD 5000 NOT AVAILABLE NOT AVAILABLE WITH BUX NOT AVAILABLE WITH BUX NOT AVAILABLE WITH TD 5000 NOT AVAILABLE NOT AVAILABLE NOT AVAILABLE NOT AVAILABLE NOT AVAILABLE WITH TD 5000 NOT AVAILABLE WITH TD 5000 NOT AVAILABLE NOT AVAILABLE NOT AVAILABLE WITH TD 5000 WITH TD 5000 NOT AVAILABLE WITH TD 5000 WITH TD 5000 NOT AVAILABLE WITH TD 5000 NOT AVAILABLE WITH TD 5000 NOT AVAILABLE NOT AVAILABLE Step and touch voltages Measurement of line impedance and of the related parameters NOT AVAILABLE NOT AVAILABLE WITH TD 5000 WITH TD 5000 The document is subject to change without notice. Always refer to our technical specification for more detailed information and as formal contract document.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Page Count : 28 Warning : Duplicate 'Im101' entry in dictionary (ignored) Author : Create Date : 2017:03:10 12:05:33+01:00 Creator : Modify Date : 2017:03:10 12:05:33+01:00 Producer : Foxit PhantomPDF Printer versione 6.0.4.1129 Subject : Title :EXIF Metadata provided by EXIF.tools