BHI, LLC Craig Sharf
38 Dana Place / Closter, NJ 07624
NJ Home Inspector Lic. # 24G100020400
NJDEP Radon Lic # Met 109-74
Phone # 201-767-2070
Fax # 201-767-3020
File Number: 315-062009-xxxx
Address of Inspection: XXXXXXXXX/ Wyckoff, NJ 07481
GENERAL DESCRIPTION:
Throughout this report, the terms "right" and "left" are used to describe the
home as viewed from the street. The term "major visual defect" is defined in the
Home Inspection Agreement, the terms of which are incorporated into this
report. A system or component has a major visual defect if it is either unsafe or
not functioning and cannot be replaced or rendered safe or functional for less
than $1,000. The HomeTeam inspects for evidence of structural failure and
safety concerns only.
If major visual defects are observed or minor repairs need to be made, we
recommend you consult a qualified licensed professional. Cost estimates are
advised prior to closing. All contractors should work for you as their
evaluation/observation may make you aware of findings not listed in our report.
The cosmetic condition of the paint, wall covering, carpeting, window
coverings, etc., are not addressed. All conditions are reported as they existed at
the time of the inspection. Routine maintenance and safety items are not within
the scope of this inspection unless they otherwise constitute major, visually
observable defects as defined in the Home Inspection Agreement. Although
some maintenance and/or safety items may be disclosed, this report does not
include all maintenance or safety items, and should not be relied upon for such
items.
This report is general in nature and not technically exhaustive.
The home was occupied and the utilities were on at the time of the inspection.
The buyer was present during the inspection. The approximate temperature at
the time of the inspection was 55 degrees Fahrenheit, and the weather was
sunny.
The inspected property consisted of a two story wood-framed structure with
wood board siding covering the exterior. The home appeared to be
approximately 60 years old. There was a brick walkway leading to the brick stoop
in the front of the home.
Observation: The home has gone through several renovations throughout the
years. The legality of any alteration or conversion of an inhabitable space in or
around the dwelling, as well as any code violations is beyond the scope of this
inspection.
The home was situated on a lightly sloped lot. The general grade around the
home appeared to be adequate to direct rainwater away from the foundation.
There was an asphalt driveway on the right side of the home which led to the
detached garage. There were no major visual defects in the driveway.
GARAGE:
The detached, wood sided, garage was designed for one moderately sized
car with access provided by one overhead-style door. The electric garage door
opener and safety were found to be functional. The concrete garage floor was in
good condition. There was one layer of shingles on the gable roof. The roof was
in good condition.
Observations;
1) The wood siding is in contact with the earth. This is conducive to rot and
wood destroying insects. This condition should be addressed.
2) You should consider installing gutters at the roof edges.
PATIO:
There was a raised screened in patio at the rear of the home. There were no
major visual defects observed on the patio. The carpet covering the floor limited
viewing of the concrete surface.
ROOF STRUCTURE:
The roof was a gable design covered with asphalt/fiberglass shingles.
Observation of the roof surfaces and flashing was performed from ground level
with the aid of binoculars. The age of the roof covering was said to be
approximately 14 years old. There was one layer of shingles on the roof at the
time of the inspection. There was slight lifting of the shingles and some surface
wear. The roof appears to be in the middle of its useful life.
This visual roof inspection is not intended as a warranty or an estimate on the
remaining life of the roof. Any roof metal, especially the flashing and valleys,
must be kept well painted with a paint specially formulated for the use.
Observation: A shingle at the rear gable was lifted slightly and this condition
should be addressed.
The roof drainage system consisted of aluminum gutters and downspouts
which appeared to be installed correctly. Gutters and downspouts should receive
routine maintenance to prevent premature failure.
Observation: Several downspouts diverted water under ground. It was not
determined from this visual inspection where this water terminated.
There was one chimney. Observation of the chimney exterior was made from
the ground, with the aid of binoculars.
Observations;
1) The furnace flue was covered with a screen. This has the potential to
block/restrict the exhausting of flue gases and this condition should be addressed
at once. A proper rain cap should be installed.
2) For safety reasons, prior to closing this older chimney should be cleaned
and re-inspected by a certified chimney contractor, as there may be hidden
internal defects not fully visible at the time of the inspection.
FOUNDATION:
The foundation was constructed of concrete block. A single inspection cannot
determine whether movement of a foundation has ceased. Any cracks should be
monitored regularly.
Observation: There were vertical cracks in the front and rear walls of the left
side crawl space. There was daylight visible through each of these cracks. It
appears that the left side foundation wall footings have settled and these cracks
are the result. At a minimum the cracks must be properly sealed. It is
recommended that you consult with a qualified structural engineer to review the
foundation and ensure its integrity. The engineer should note that the floors on
the left side of the home have an obvious slope.
BASEMENT:
The basement was unfinished, and contained the following mechanical
systems: a boiler and hot water heater.
The basement was dry at the time of the inspection. Because the basement
is below grade, there exists a vulnerability to moisture penetration after heavy
rains.
Observations;
1) The stored items did not permit a complete visual inspection of the
foundation.
2) There was a small water stain on the slab floor under the water meter. The
hose bib / valve above the meter appears to have a slight drip and this should be
addressed.
3) There was asbestos like material on the pipes in the basement and the left
side crawl space. The only way to be sure of asbestos is to have the material
tested. Asbestos should either be properly removed or encapsulated.
4) Possible problem areas may not be identified as the foundation walls and
slab floor surfaces have been painted.
CRAWL SPACE:
There were two crawl spaces. The left side crawl space was accessible at
the time of the inspection. The right side space was viewed from the hatch
opening.
Observations;
1) The dirt floor of the left side space should be covered with a vapor barrier
to help control humidity levels.
2) There was water in the left side space, however it appears to be a
plumbing issue. See Plumbing section of this report.
3) See previous comments regarding the foundation and asbestos in the
basement.
FLOOR STRUCTURE:
The visible floor structure consisted of a tongue and grove subfloor, supported
by two-inch by ten-inch wood joists spaced sixteen inches on center. There was
a six by eight-inch wood center beam and four-inch steel posts for load bearing
support.
Observation: The floor joists were notched at the center beam. Several of the
joists were cracked at this load bearing point. Repairs are needed. While the
structural engineer is reviewing the foundation he should review this issue.
PLUMBING:
The visible water supply lines throughout the home were copper pipe. The
water was supplied by a public water supply. The visible waste lines consisted of
lead, caste iron, and PVC pipe. The home was connected to a public sewer
system. Water flow throughout the home appears to average.
Observation: There was a plumbing leak in the left side crawl space, at the
common wall of the basement. This condition should be addressed by a qualified
plumber. All repairs should be properly documented.
The main water shutoff valve for the home was located adjacent to the water
service entry point in the basement.
The gas meter was located on the basement wall. Although no actual testing
was performed to detect the presence of gas fumes, there was no noticeable
odor of gas detected at the time of the inspection.
There was a 40 gallon capacity, natural gas water heater located in the
basement. The water heater was manufactured by Bradford White, model
number MI40 and serial number BE6220950. Information on the water heater
indicated that it was manufactured 4 years ago. A temperature and pressure
relief valve (T & P) was present. Because of the lime build-up typical of T & P
valves, we do not test them. An overflow leg was present. It did terminate close
to the floor. Your safety depends on the presence of a T & P valve and an
overflow leg terminating close to the floor. The water heater was functional.
There was a sump pump located in the basement. The sump pump was not
functional.
Observation: The sump pump needs to be replaced. At the time of
replacement, the drain line should be changed to a PVC pipe and a back-up
battery should be installed.
ELECTRIC SERVICE:
The overhead electric service wire entered the home on the front wall. The
electric meter was located on the front exterior wall. The service wire entered a
Square D service panel, located on the basement wall with 100-amps and a
120/240 volt rated capacity. The branch circuits within the panel were copper.
These branch circuits and the circuit breakers to which they were attached
appeared to be appropriately matched. The visible house wiring consisted
primarily of the Romex and BX type and appeared to be in good condition.
A representative number of installed lighting fixtures, switches, and
receptacles located throughout the home were inspected and were found to be
functional. The grounding and polarity of receptacles within six feet of plumbing
fixtures, and those attached to ground fault circuit interrupters (GFCI), if present,
were also tested. All GFCI receptacles and GFCI circuit breakers should be
tested monthly.
The electrical service appeared to be adequate. Alarms, electronic keypads,
remote control devices, landscape lighting, telephone and television, and all
electric company equipment were beyond the scope of this inspection.
Observations;
1) In several locations there were two-pronged outlets. At the time this home
was constructed, two-prong outlets were the standard construction. However, the
two-pronged plugs were not grounded (open-ground), and are not considered to
meet the safety standards of modern wiring.
2) The installation of GFCIs in the kitchens, all bathrooms, or any receptacle
that is in the proximity of a water source (moisture) is recommended. This will
increase the overall safety of the electrical system.
WINDOWS, DOORS, WALLS AND CEILINGS:
A representative number of accessible windows and doors were operated.
The primary windows were older models and they were constructed of wood,
double hung style, with single pane glass. All exterior doors were operated and
found to be functional. The exterior door locks should be changed or rekeyed
upon occupancy.
The interior wall and ceiling surfaces were finished with plaster, wood
paneling, and drywall. Possible problem areas may not be identified if the interior
wall and ceiling surfaces have been recently painted.
FIRST FLOOR:
The first floor consisted of a living room, dining room, kitchen, two bedrooms,
and a full bathroom. The HomeTeam inspects for evidence of structural failure
and safety concerns only. The cosmetic condition of the paint, wall covering,
carpeting, window coverings, etc., are not addressed.
In the kitchen the visible portions of the cabinets and counter tops were in
good condition. The appliances were turned on to check operational function
only. No warranty, express or implied, is given for the continued operational
integrity of the appliances or their components. The kitchen contained the
following appliances:
The Gaggenau natural gas cook top and Kitchen Aid electric oven were
inspected and did appear to be functional. The accuracy of the clock, timers and
settings on ovens are not within the scope of this inspection.
The Amana refrigerator was inspected and did appear to be functional. The
temperature setting and ice maker, if present, are not within the scope of the
inspection.
The Whirlpool dishwasher was observed through complete cycle and did
appear to be functional when set on the "wash" and "drain" cycles.
SECOND FLOOR:
The second floor of the home consisted of two bedrooms and a bathroom.
FIREPLACE:
There was one fireplace in the home. Its visual condition at the time of the
inspection is indicated as follows.
There was a wood burning fireplace in the living room. The damper did
appear to be functional. There was no visual evidence of creosote buildup in the
firebox and/or chimney. There were no cracks observed in the firebox or visible
portions of the chimney.
The fireplaces were not tested for operation or function.
ATTIC STRUCTURE:
There was no true attic space. The front and rear eve spaces were accessed
via knee wall doors. The insulation covering the roof sheathing did not permit
viewing of the roof structure. Stored items also limited viewing of the space.
The only way to be sure a roof does not leak is to inspect the underside of the
roof during a heavy rain.
HVAC INSPECTION REPORT:
The results of our visual and operational inspection of the heating system are
described below. Periodic preventive maintenance of the equipment is essential
for safe and efficient performance and will help to maximize the system's useful
life.
The home was heated by a Dunkirk natural gas steam boiler, serial number
128900159, Model Number JB542, which is approximately 20 years old. The
unit was located in the basement of the home. It has an approximate net heating
capacity of 112,000 BTUH. Heat is delivered via radiators throughout the home.
NOTE: Without removing the burners to gain complete access to the boiler,
and with the limited viewing area of the heat exchanger, a thorough inspection is
not possible.
The heating system was found to be functional. The boiler flame did ignite
when the temperature was raised at the thermostat. The flame burned a strong
blue color. A strong blue color indicates complete combustion of the fuel. This is
necessary for the safe, efficient use of this boiler.
Observations;
1) This 20 year old appliance has met the manufacturer's life expectancy. You
will need to budget for repairs, if not replacement.
2) Examination of heating system is mechanically limited since the unit is not
dismantled to examine interior components. The heating system should be
inspected and serviced on an annual basis. We recommend obtaining from the
seller well before close of escrow any documents concerning regular
maintenance. In lieu of these documents a complete system evaluation by a
qualified heating specialist is recommended, particularly if the heating system
cannot be proven to have been serviced within the past twelve months.
CONTROLS:
The controls for the heating system was 24 volt thermostat. The thermostat
was found to be in working order.
RADON INSPECTION:
Radon gas is a colorless and odorless gas released into the ground as a
result of uranium decay. This invisible gas can be hazardous to your health in an
enclosed structure. The radon test you requested was performed by Radiation
Data. Their radon inspection report will follow in five to seven days.
PEST INSPECTION:
The pest inspection was performed by Terminite Inc. Their report is attached.
OIL TANK EXCLUSION:
An under ground oil storage tank was not part of this inspection. Although
one may have existed at one time on the property, when natural gas was not
available. Hence its proper closure was not verified. You should consult with your
attorney regarding this matter.