XG Series
WWW.PROGRAMMABLEPOWER.COM
850 & 1700 Watt DC Programmable Power Supplies
Sorensen XG 850 & 1700 Series
Now, 1700W of Power in a 1U Power Supply
The Sorensen XG 850 & 1700 Series are industry leading programmable DC
power supplies designed for test, production, laboratory, OEM and quality
assurance applications. The newest member of the family, the XG 1700,
is a high power density 1700 Watt, 1U programmable power supply with
constant voltage and constant current modes, automatic cross-over and
numerous features enabling cost effective, easy system integration.
Easy System Integration
The Sorensen XG Series of system power supplies are designed for ease of
integration into automated test and other equipment.
Remote Serial Programming:
Digital programming is exible and easy, because in addition to precise,
digital encoder front panel control and simultaneous voltage and current
displays, the XG includes standard RS232/RS485 and USB remote control
interfaces. It also offers optional GPIB and LXI Class C Ethernet control
inputs. Commonly used, SCPI compliant, device drivers are available to
support system applications. To allow for fast programming and to unload
your system controller, DC voltage or current sequences can be programmed
into a specic memory location, using compliant SCPI commands. The XG
supports autonomous program sequencing with the capability to store,
recall and execute pre-programmed test routines including the operation of
the auxiliary outputs, minimizing command latency and system controller
overhead and thereby maximizing system throughput.
One example is to simulate the engine startup standard used in the
automotive industry. This unique Auto Sequence Programming functionality
is additionally powerful combined with the XG’s excellent slew-rate
specications.
Simple Multi-Channel Serial Control:
The XG Series, like most of the Sorensen DC power supplies, provides a
multi-channel control system. With this method, it is possible to congure
many power supplies into a one-master, multi-slave, single multi-channel
power-sub-system. One master can control up to 30 slave-units through a
simple cable (RS-485) using RJ-45 connectors.
This method of multi-channel control is much easier to manage from a
software programming point of view and provides much less complexity
from an interfacing and wiring point of view (one single GPIB or IP address
controlling multiple DC output channels).
Key Features
• Standard Digital Interfaces – USB & RS232/485
Auxiliary 5V / 15V outputs
• LXI Ethernet and Isolated analog interfaces
• Power Factor Correction – PFC & universal AC input
• Sleep Mode – Auto “sleeps” after period of non-use (1700 only)
• Easy “cover on” soft calibration
• Programmable fold-back protection delay
Applications
Burn-in Compliance Testing
Materials Research Process Control
Product Validation Automotive Electronics
Rack ATE Systems Battery Charging
Output Auto Start Mode (Auto Restart)
The Auto Start mode establishes the state of the output of the power supply
after recovery from a complete power cycle (all front panel LEDs are not
illuminated), or after recovery from a PC failure or reboot. If Auto Start mode
is set to On, the power supply output will return to its previous value. Also,
after the loss of any remote digital control, the XG unit will remain active in
its last programmed setting and will not disrupt any test process.
Auxiliary Auto Start Mode
The Auxiliary Auto Start mode determines the state of the auxiliary output
after a complete power cycle (all front panel LEDS are not illuminated). With
Auxiliary Auto Start mode turned to On, the auxiliary output will be activated
after the power supply is powered up again.
Digital I/O Features with Analog Control
Most DC power supplies provide a 0 to 5 or 0 to 10 V analog control range
to control the DC output from zero to full DC output range. But what if these
analog control-signals are not exactly covering the range you need? XG
analog control and read-back full scale signals can be user dened, from 0
to 2V to 0 to 10V, facilitating easy substitution of the XG into existing test
or process control systems.. In fact, it’s just a push-of-a-button front-panel
exercise, to make the XG compatible with your analog control system.
Included Auxiliary Outputs
In many ATE systems one or more low power, xed voltage supplies are
needed to power accessories within the system. For this purpose, the XG
Series provides two auxiliary DC output channels, 5V / 15V each 0.4 Amps.
Both auxiliary power channels are switchable directly from the front-panel or
through SCPI commands. In this way, it is possible to drive output disconnect
or polarity reversal relays, without needing a complicated computer
controlled relay board, further reducing system cost and complexity.
Environmental Features
Variable Fan Speed Control: The XG’s innovative approach to fan speed is
determined by internal heat sink temperature. This allows the fans to adjust
to a constant optimal speed when the output of the supply is being pulsed,
which reduces audible noise and increases fan life.
Power Saving Standby Mode (1700 Only): When the XG 1700 has been in
an idle state, the supply can go into “sleep mode”, much like a computer
monitor. This will allow the user to save energy and minimize lab noise. Since
an XG 1700 left in sleep mode is still “on” the user will have quicker access
to an enabled output.
Quick-connect spring-terminal-block
DC output disconnect relays controlled by
auxiliary output channels
Model Number Description
XG 33
Series
Voltage
25
Current
(XXX)
Options
850 Watt & 1700 Watt DC Programmable Power Supplies
Sorensen XG 850 & 1700 Series
Output
1700 Models Output Voltage 3Output Current 4
XG 6-220 6 V 220 A
XG 8-200 8 V 200 A
XG 12-140 12 V 140 A
XG 20-84 20 V 84 A
XG 33-50 33 V 50 A
XG 40-42 40 V 42 A
XG 60-28 60 V 28 A
XG 80-21 80 V 21 A
XG 100-17 100 V 17 A
XG 150-11.2 150 V 11.2 A
XG 300-5.6 300 V 5.6 A
XG 600-2.8 600 V 2.8 A
Line and Load
Line Regulation Voltage (0.005% of rated output voltage +2 mV) 5
Line Regulation Current (0.01% of rated output current +2 mA) 6
Load Regulation Voltage (0.005% of rated output voltage + 2 mV) 7
Load Regulation Current (0.02% of rated output current +5 mA) 8
AC Line Input Specications
Operational AC Input
Voltage/Frequency 85–265 Vac continuous, 47–63 Hz, single phase
Power Factor Correction 0.99@100/200 Vac, rated output power
Programming Mode APG Digital
Voltage Programming
Accuracy (mV)1
± 0.5% of rated
output voltage,
max (0-4V/4K range)
± 0.1% of rated
output voltage
Current Programming
Accuracy (mV)1
± 1% of rated
output current,
max (0-4V/4K range)
± 0.2% of rated
output current
Output Performance Specications
Transient Response Time 2Less than 1 ms for 6 V to 60 V models.
Less than 2 ms for 80 V to 600 V models*
Environmental Specications (Indoor use)
Operating Temperature Range 32°F to 122°F, 100% load (0°C to 50°C)
Regulatory Approvals
Safety CSA 22.2 No. 61010-1 and UL61010-1. Marked with cCSAus,
CE EN61010-1
EMC Complies with EN61326-1
Complies with EN55011, Class A, FCC Part 15A for
conducted emissions
Complies with EN55011 Class A, FCC Part 15A for
radiated emissions
Complies with EN61000-4 series of standards for immunity
* Typical
1. Typical APG or isolated APG accuracy can be improved to max accuracy by user calibration
at the specic range selected.
2. Time for the output voltage to recover within 0.05% at its rated output for a load change
10-90% of rated ouput current. Output set point 10-100%
3. Minimum output voltage is guaranteed to be ≤ 0.2% of the rated voltage at zero output setting.
4. Minimum output current is guaranteed to be ≤ 0.4% of the rated current at zero output setting
when measured with rated load resistance.
5. From 85-132 Vac or 170-265 Vac, constant load.
6. From 85-132 Vac or 170-265 Vac, constant load.
7. From no load to full load, constant input voltage.
8. For load voltage change, equal to the unit voltage rating, constant input voltage.
Note: Full data sheet with detailed specs available at www.programmablepower.com
Note: All specications are subject to change.
AMETEK Programmable Power
9250 Brown Deer Road
San Diego, CA USA 92121-2267
Web : www.programmablepower.com
Email : sales@programmablepower.com
Phone : 858.458.0223
Feature XG 850 XG 1700 Order Option
USB Interface Standard Standard
RS232 Interface Standard Standard
Power Factor Correction Standard Standard
Isolated Analog Interface Standard Option MIA
GPIB, IEEE 488.2 Option Option MGA
Ethernet Option - MEA
Rackmount Angle Brackets Option Option RM-XG1
Rackmount Kit for 1 unit Option N/A RM-S-XG1
Rackmount Kit for 2 units Option N/A RM-D-XG1
850 Models Output Voltage 3Output Current 4
XG 6-110 6 V 110 A
XG 8-100 8 V 100 A
XG 12-70 12 V 70 A
XG 20-42 20 V 42 A
XG 33-25 33 V 25 A
XG 40-21 40 V 21 A
XG 60-14 60 V 14 A
XG 80-10.5 80 V 10.5 A
XG 100-8.5 100 V 8.5 A
XG 150-5.6 150 V 5.6 A
XG 300-2.8 300 V 2.8 A
XG 600-1.4 600 V 1.4 A
Mechanical Specications
XG 1700 Watt (W×H×D)
16.8 x 1.7 x 19.0 inch (429 x 43.6 x 483 mm
without rack mount ears)
XG 850 Watt (W×H×D)
8.4 x 1.7 x 19.0 inch (214 x 43.6 x 483 mm)
XG 1700 Watt
Weight 22 lb (10 kg)
XG 850 Watt
Weight 11 lb (5 kg)
Cooling Forced air cooling by internal fans