SeL_207_XL_INST_1_plain Sunvic Sp2 Programmer Select 207
User Manual: Sunvic-sp2-Programmer Select 207
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
http://waterheatertimer.org/Woods-timers-and-manuals.html#Noma-Garrison Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central heating and domestic hot water on and off at the same time, while others allow the domestic hot water and heating to come on and go off at different times. Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen ‘On’ and ‘Off’ heating periods, or be permanently off. The time on the programmer must be correct. Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the heating programme, for example, ‘Override’, ‘Advance’ or ‘Boost’. These are explained in the manufacturer’s instructions. The heating will not work if the room thermostat has switched the heating off. And, if you have a hot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature. SELECT 207XL USER INSTRUCTIONS COP DA AD MO TU WE TH FR SA SU AD ON AUTO ALLDA ON +1H R +1h ON OFF RU SET +1H NEXT TIMES RESE +1hr ADV SELECT HW SELECT CH BUTTON CENTRAL HEATING AD + HOT WATER INTRODUCTION This central heating programmer can automatically switch your central heating and hot water ON and OFF, independently, up to 3 times a day, at whatever times you choose. During installation, the installer selects 24 hour, or 5 day/2 day, or 7 day programming and 2 or 3 on/off periods per day, via a 4 position DIP switch on the back of the unit (see installation instructions). IMPORTANT: These settings should only be changed by a qualified person. Contact your installer. The 24 hour programmer option runs the same programme every day. The 5 day/2 day programmer options allows different ON/OFF times at weekends. The 7 day programmer option allows different ON/OFF times for each day of the week. The unit is designed to eliminate the possibility of accidental changes to your programme. Buttons normally visible, only affect your set programme temporarily. All buttons which can permanently change your programme are located behind the flip-down fascia. SELECTING OPERATING MODE The Heating and Hot water mode select buttons are used to set the operating mode for CENTRAL HEATING and HOT WATER respectively. Each has 4 modes as described:ADV ON AUTO ALLDAY OFF Heating mode Selection button And indicator +1hr MO TU WE TH FR SA SU ADV 12 : 00 RUN ON AUTO ALLDAY OFF ON OFF Hot Water mode Selection button And indicator +1hr ON Central heating and/or Hot water on continuously (I.E. All the time). AUTO Central heating and/or Hot water will be switched On or Off as programmed ALLDAY Central heating and/or Hot water will be switched On only once each day. It will switch ON at the first ON time and OFF at the last OFF time. OFF Central heating and/or Hot water continuously OFF. Press the SET button once. The display will flash above the clock. Press the +/- buttons to adjust the time. Hold down button to change time quicker. Press DAY button to move indicator to Current day. Press SET button repeatedly to move Indicator to RUN position. NOTE: The unit will automatically return To run mode if a period of 5 minutes passes Without any buttons being pressed. ADV ON AUTO ALLDAY OFF +1hr MO TU WE TH FR SA SU 12 : 00 RUN ADV ON AUTO ALLDAY OFF ON OFF +1hr BST/GMT TIME CHANGES To move the time forward or back 1 hour, press and hold for 3 secs, the TIME +/- button (as appropriate), while the unit is in run mode. CHANGING PROGRAMME TIMES The two built in programmes, one for Central Heating and one for Hot water, can easily be changed to better suit your needs. ADV To change the Central heating programme Press SET button repeatedly until the display Indicator is flashing above the radiator symbol. An indicator will appear above ON and the Number1 will show above it. This indicates the time shown on the display is the first ON time. Change this to the required time by pressing the +/- buttons. Press NEXT button to move indicator to above OFF. Time now shown is the 1st OFF time. Change as before. Use the NEXT and +/- buttons in this way to Program the second time period. If the unit is set for three ON /OFF periods, the Number 3 will appear. This is set in exactly the same way as the previous second time period. ON AUTO ALLDAY OFF +1hr ADV ON AUTO ALLDAY OFF +1hr MO TU WE TH FR SA SU 12 : 00 RUN 1 RUN ON AUTO ALLDAY OFF ON OFF MO TU WE TH FR SA SU 12 : 00 ADV 1 +1hr ADV ON AUTO ALLDAY OFF ON OFF +1hr If unit is installed as a 7 day programmer, the initial programme displayed will be for Monday. You can go to any day of the week by pressing DAY button repeatedly. The ON/OFF times can be changed for each day as above. If you press COPY button, the current programme will be copied into the next day. If unit is installed as a 5day/2day programmer, the initial programme displayed will be for Monday to Friday. Pressing DAY button will take you to the programme for Saturday and Sunday. The ON/OFF times can be changed for each day group as above. If you press COPY button, the current programme will be copied into the next day group. If the unit is installed as a 24hr. Programmer, the built in programme will be the same for each day (as for Monday to Friday). The COPY function is not required if installed as a 24 hr. programmer. To return to RUN mode, press SET button until the display indicator returns to above the RUN position. To change HOT WATER programme Press SET button repeatedly until flashing indicator on display is above the tap symbol and proceed exactly as Central heating above. Note It is not possible to copy Sunday to Monday. For convenience to allow for programmes to go past midnight, the programme day is from 03:00am to 02:50am the next day. If your programme gets scrambled, or you want to start again, press the reset button using a non-metallic tool to re-load the default programmes, then press any button to clear the DIP switch configuration code. The unit should revert to time setting mode ready for programming. USING ADVANCE This function is only available when programme is in AUTO or ALLDAY operating modes. To Advance Central Heating ADV Press the left hand ADV button. This will turn Central heating ON if it was in an OFF period And vice versa. It will stay in this state until either ADV is pressed again, or until a programmed ON/OFF commences. An indicator will appear on display top left hand Corner, pointing at ADV. This is normally covered By the flip down front fascia panel. ON AUTO ALLDAY OFF +1hr MO TU WE TH FR SA SU 12 : 00 RUN ADV ON AUTO ALLDAY OFF ON OFF +1hr 1 To Advance Hot Water Press the right hand ADV button. This will turn Hot Water ON if it was in an OFF period And vice versa. It will stay in this state until either ADV is pressed again, or until a programmed ON/OFF commences. An indicator will appear on display top left hand Corner, pointing at ADV. This is normally covered By the flip down front fascia panel. ADV ON AUTO ALLDAY OFF +1hr MO TU WE TH FR SA SU 12 : 00 RUN ADV ON AUTO ALLDAY OFF ON OFF +1hr USING+1HR. For +1hr Central Heating Press the left hand +1hr button. If the central Heating operating mode is OFF then it will switch on for 1 hr. If the central heating operating mode is AUTO or ALLDAY, then during an OFF period, it will switch on for 1hr. If during a ON period, then it will temporarily MO TU WE TH FR SA SU ADV ADV extend that programme by 1hr. An indicator will appear on display lower left corner pointing at +1hr. This is normally covered by the flip down front fascia panel. Pressing +1hr again cancels this function. When in the ON mode the +1hr button has no effect. ON AUTO ALLDAY OFF +1hr 12 : 00 RUN ON AUTO ALLDAY OFF ON OFF +1hr USING+1HR. For +1hr Hot Water Press the right hand +1hr button. If the hot water operating mode is OFF then it will switch on for 1 hr. If the hot water operating mode is AUTO or ALLDAY, then during an OFF period, it will switch on for 1hr. If during a ON period, then it will temporarily MO TU WE TH FR SA SU ADV ADV extend that programme by 1hr. An indicator will appear on display lower right corner pointing at +1hr. This is normally covered by the flip down front fascia panel. Pressing +1hr again cancels this function. When in the ON mode the +1hr button has no effect. ON AUTO ALLDAY OFF +1hr 12 : 00 RUN ON AUTO ALLDAY OFF ON OFF +1hr POWER INTERRUPTION In the event of mains supply failure, the back up battery ensures programmer continues to keep time and retain your stored programme. The screen will go BLANK, but will return when power is restored. If left continuously without power for more than 30 days, it will stop keeping time. When power is restored, it will be necessary to reset time and day. BATTERY REPLACEMENT Replace with a 3v Lithium button cell type Cr2032. Fit into the back of the unit, observing correct polarity as marked. RESET BUTTON Press the reset button with a non-metallic pointed tool to restore the built in programme. The display will then show the current state of the configuration switches. LINKING CENTRAL HEATING AND HOT WATER If required, it is possible to set both central heating and hot water to follow the same program. This is done by holding the COPY button down, while pressing reset. This simplifies programming as changes need only be made once, and will affect both central heating and hot water. Configuration Display 2 on/2off/pumped 2 PU 3 on/3off/pumped 3 PU 2 on/2off/gravity 2 GA 3 on/3off/gravity 3 GA Mon to Sun day indicators 7 day Mon to Sun successively on 5/2 day Mon to Fri on alternating with Sat, Sun on 24Hr Mon to Sun all on together E.G. 24hr. 2 on/2off pumped, would look like this:ADV ON AUTO ALLDAY OFF +1hr MO TU WE TH FR SA SU 2 PU RUN ADV ON AUTO ALLDAY OFF ON OFF +1hr NOTE The last letter of the display (i.e. the U or the A) will be L, if central heating and hot water have been linked. E.G. 2 PL = 2on/2off pumped, linked CH/HW Press any button to revert to time setting mode. The unit is then ready for programming. See SETTING TIME OF DAY section. Factory programme settings Mon-Fri Sat&Sun BUILT IN PROGRAMME 1st ON 6:00am 7:00am st 1 OFF 8:30am 9:00am For convenience, the programmer has a built in programme which for many people is perfectly 12:00 noon 12:00 noon 2nd ON satisfactory, but it can be changed quite easily nd 2 OFF 12:00 noon 12:00 noon (see section CHANGING PROGRAMMING TIMES) 4:30pm 11:00pm 3rd ON rd OFF 10:30pm 11:00pm 3 If the unit is installed as a 24 hour programmer, the built in programme will be the same for each day (as Mon. to Fri. above). Installation Instructions SELECT207XL Programmer Select 207xl Technical Data Power supply Ambient temperature Total Input Switch Rating Battery type Battery back up Wiring Maintenance Disconnection class 230v AC 50Hz. Operating 0°C to 35°C 6A 230vAC 6(2)A 3v Lithium button Cr2032 30 days(Time & programme) For fixed wiring only No user maintenance reqd. 1B This unit must be installed by a competent person in accordance with the latest appropriate wiring regulations. All 3 port spring return motorised valves can remain powered ON in the CH position after the Pre Installation set-up demand for heating has been satisfied, even if the boiler and the pump are switched off. It can be left Before installing, set the bank of 4 DIP switches on all night, using twice as much energy as it on the back, to configure the unit according to the should. The valve will only return from this chart below. ‘latched’ position to the HW position after a demand for HW or HW & CH together. This can gravity Pumped lead to motor burn out, and failure of any make of 3 port spring return motorised valve. 7 day The Select 207 programmer is supplied with a 24Hr patented system to prevent this ‘latching’. 5/2 day Whenever the programme stops calling for CH, it 2 on/offs 3 on/offs sends a signal to the valve to fully switch it off. This will significantly prolong the life of all makes of 3 port spring return motorised valves and save DIP switches shown in factory default position energy. The Select 207 is supplied with ‘DEPumped – Allows independent control of CH and LATCH’ activated. (It has no effect on 2 port valves). HW. Gravity – Does not allow CH without HW, but can To de-activate the ‘DE-LATCH’, cut the link as indicated on the back of the programmer before Provide HW without CH. 24Hr. Runs same programme every day installing. 5/2 Day - Allows different ON/OFF times at INSTALLATION weekend 7 Day - Allows different on/off times every day This unit is compatible with many other programmers and may be fitted to existing standard wall plates. Please consult the ‘WIRING Locate the back up battery, remove packing and INTERCHANGE GUIDE’ for compatible fit to the back of the unit, observing correct programmer types. Some are directly polarity as marked. interchangeable, others will require minor This will ensure times and programme settings changes to wiring connections. are maintained during temporary power Be sure to switch off the mains supply before interruptions. starting. Please read all installation instructions before proceeding. When unit is first switched on, or when the reset Ensure that the fixed wiring connections to the button is pressed, the status of the DIP switches mains supply, is via a fuse rated at not more is displayed. 6 amps, and a class ‘A’ switch, having a contact Energy saving feature separation of a minimum of 3mm in all poles. Sunvics patented ‘De-Latch’ saves energy and increases the life of 3 port spring return motorised valves. DIRECT UPGRADE FOR EXISTING PROGRAMMERS 1.Switch off mains. Loosen 2 securing screws on old programmer and unplug it. 2.Check existing wall-plate has been correctly fitted. (See section,Fitting wall plate) 3.Plug SELECT programmer into wall-plate and re-tighten screws. Switch on at mains. 4.Press RESET button located behind the flipdown fascia panel. The status of the DIP switch settings will be displayed. Pressing any button will cause the display to go to time setting mode. 5.Set timing and programme as detailed in user guide FITTING WALL PLATE 1.Position the wall-plate (terminals along the top edge) with 60mm(Min) clearance to its right, 25mm(Min) above, 90mm(Min) below. Ensure that the supporting surface will fully cover the back of the programmer. 2.Ideal location would be 1.4m above floor level, easily accessible, reasonably lit and free from condensation or temperature extremes. 3.Fix the wall-plate to a flush mounting single conduit box type UA1(BS4662) using M3.5 x 14 bolts. 4.Ensure that the wiring to the wall-plate terminals leads directly away from the terminals and is completely enclosed within the wall-plate aperture. Wire ends must be stripped and screwed to the terminals, so that minimal bare wire is showing. 5.If the unit is fitted to a metal surface, IT IS ESSENTIAL that the metal be earthed. Do not use a surface mounting box. 6.Ensure the mains supply is switched off, then make wiring connections. No EARTH connection is required, but ensure continuity of EARTH throughout the system. 7.After wiring, plug unit into wall plate and tighten the securing screws. Switch on at mains. 8.Press RESET button located behind the flipdown fascia panel. The status of the DIP switch settings will be displayed. Pressing any button will cause the display to go to time setting mode. 9.Setting timing and programme as detailed in user guide. 10.NEVER fit or remove the unit to a LIVE wall-plate. This product complies with the essential requirements of the following EC Directives: Electro-magnetic compatibility directive EMC 89/336/EEC (as amended by 91/263/EEC And 92/31/EEC Low Voltage directive LVD 73/23/EEC;93/68/EEC Programmer Internal Wiring Diagram Electronics N L Mains Fused 6Amps 1 HW OFF 2 3 4 CH OFF HW ON CH ON SUNVIC CONTROLS Ltd. Bellshill Road Uddingston Glasgow G71 6NP Tel 01698 812944 Fax 01698 813637 Tech Helpline 01698 810945 Tech Help. Fax 01698 307437 WWW.sunvic.co.uk In the interests of continuous product improvement, Sunvic Controls reserve the right to alter designs, specifications and materials, without prior notice, and cannot accept liability for error. Installation leaflet LE/497/0001 ISSUE 01 FEB 2003 DIRECT PLUG-IN REPLACEMENT FOR EXISTING PROGRAMMERS Programmer will plug directly onto existing wall-plates of the following programmers without any rewiring, just follow the installation instructions. MANUFACTURER ACL DANFOSS RANDALL MODEL LP112, LS241, LS522 LS722, LP241, LP522 LP722 FP75, FP15, CP75, CP15 DRAYTON TEMPUS 3 & 4 & 7 MANUFACTURER LANDIS &GYR MODEL RWB2, RWB2.9, RWB 102 RWB200, RWB252, RWB20, RWB40 MINIMINDER POTTERTON GLOW-WORM MASTERMIND SUNVIC SELECT 207 Otherwise fit new wall-plate supplied, and refer to wiring interchange guide below. WIRING INTERCHANGE GUIDE When replacing any of the below with your Sunvic SELECT 207XL programmer, fit new wall-plate supplied and follow the connection details shown. Whilst every effort is made to ensure accuracy of the instructions given, you will appreciate that discrepancies may occur, due to various reasons outside of our control. Make Model Sunvic SELECT 207XL Terminals N L 1 2 3 SP100 & SP50 N L 1 4 2 5 SP2 N L 1 4 3 6 Satchwell Libra & DHP2201 1 2 8 5 6 3 Satchwell ET1401 & ET1451 1 2 8 5 7 4 Honeywell ST699B & C N L 7 4 6 3 ST499A N L - - 6 3 ST6300 & ST6400 N L 1 2 3 4 ST7100 N L 7 4 8 5 MP 2 1 - - 6 10 FP 2 1 8 11 6 10 2000 N L hw off ch off 922 & 972 N L 1 4 3 6 2 ACL Randall hw on 4 ch on 4033 7 6 5 3 4 701 N L - - 3 1 702 N L 4 2 3 1 102 5 6 - - 1 2 3060 & 3020P 1&7 6 - - 4 2 3033 1&7 6 5 3 4 2 N L 3 6 1 4 3&6 7 2 5 1 4 MK11 R6 3 1&2 - - 4 5 TSR2P 3 1 - - 5 7 4&5 3&6 2 7 1 8 M5 4 3 - - 1 6 Potterton EP2000 & EP3000 N L 1 2 3 4 Horstmann Amethyst 7 & 10 2 1 4 6 5 7 Coral 2 1 - - 8 4 Diadem N L 3 6 1 4 Diamond N L - - 2 4 Gem 2 1 6 9 4 7 Leucite 2 1 8 4 3 6 Smiths Centroller N L 1 2 3 4 Switchmaster 400 & 600 N L - - 3 1 805 & 900 & 9000 N L 4 2 3 1 Thorn Microtimer N L 7 4 6 3 Towerchron T2002 T2000 & T2003 N N L L HW HW ON CH CH On SET2 & SET5 TSR3+3 Sangamo 410F1 & F9 & F414 HW OFF CH OFF
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2007:08:10 11:24:28-03:00 Create Date : 2007:08:10 11:24:28-03:00 Format : application/pdf Title : Microsoft Word - SeL_207_XL_INST_1_plain.doc Creator : Martin Document ID : uuid:47de685c-c98a-4548-aee5-0611e22a11f3 Instance ID : uuid:efd681d2-2bfd-43f0-b146-163dd67180b9 Page Count : 8 Author : MartinEXIF Metadata provided by EXIF.tools