SymbolsGlossary_v1 Symbols Glossary V1.4
User Manual: SymbolsGlossary v1.4
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
OMRON Healthcare, Inc. Symbols Glossary Symbol Standard No./Standard Title Standard Reference No. / Symbol Title Symbol Meaning ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.1.1 / Manufacturer Indicates the medical device manufacturer ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.1.2 / Authorized representative in the European Community Indicates the authorized representative in the European union. Symbol is accompanied by the name and address of the authorized representative adjacent to the symbol ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.1.3 / Date of Manufacture Indicates the date when the medical device was manufactured ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.1.4 / Use-by-date Indicates the date after which the medical device is not to be used ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.1.5 / Batch code Indicates the manufacturer’s batch code or lot can be identified ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied Indicates the manufacturer’s catalogue 5.1.6 / Catalogue number number so the medical device can be identified ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.1.7 / Serial number Indicates the manufacturer’s serial number so that a specific medical device can be identified ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.2.8 / Do not use if package is damaged Indicates a medical device that should not be used if the package has been damaged or opened ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.3.1 / Fragile, handle with care Indicates a medical device that can be broken or damaged if not handled carefully ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.3.4 / Keep dry Indicates a medical device that needs to be protected from moisture Symbol Standard No./Standard Title Standard Reference No. / Symbol Title Symbol Meaning ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.3.5 / Lower limit of temperature Indicates the lower limit of temperature to which the medical device can be safely exposed ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.3.6 / Upper limit of temperature Indicates the upper limit of temperature to which the medical device can be safely exposed ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.3.7 / Temperature limit Indicates the temperature limits to which the medial device can be safely exposed ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.3.8 / Humidity limitation Indicates the range of humidity to which the medical device can be safely exposed ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.3.9 / Atmospheric pressure limitation Indicates the range of atmospheric pressure to which the medical device can be safely exposed ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.4.3 / Consult instructions for use Indicates the need for the user to consult the instructions for use ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied 5.4.4 / Caution Indicates the need for the user to consult the instructions for use for important information such as warnings and cautions IEC 60417 / Graphical 5333 / Type BF applied symbols for use on equipment part Identifies a type BF applied part complying with IEC 60601-1 IEC 60417 / Graphical 5840 / Type B applied symbols for use on equipment part Identifies a type B applied part complying with IEC 60601-1 Identifies equipment meeting the safety IEC 60417 / Graphical 5172 / Class II equipment requirements specified for Class II equipment symbols for use on equipment according to IEC 61140 IEC 60417 / Graphical 5926 / Polarity of d. c. symbols for use on equipment power connector Identifies the positive and negative connections of a d. c. power supply IEC 60417 / Graphical 5957 / For indoor use symbols for use on equipment only Identifies electrical equipment designed for indoor use Symbol Standard No./Standard Title Standard Reference No. / Symbol Title Symbol Meaning Indicates that the equipment is suitable for IEC 60417 / Graphical 5032 / Alternating Current alternating current only; to identify relevant symbols for use on equipment terminals IEC 60417 / Graphical 5031 / Direct current symbols for use on equipment IEC 60417 — Graphical Symbols for Use on Equipment Indicates that the equipment is suitable for direct current only; to identify relevant terminals Indicates generally elevated, potentially hazardous, levels of non-ionizing radiation, 5140 / Non-ionizing or to indicate equipment or systems e.g. that electromagnetic radiation intentionally apply RF electromagnetic for diagnosis or treatment IEC 60417 / Graphical 5009 / Stand-by symbols for use on equipment Identifies the switch or switch position by means of which part of the equipment is switched on in order to bring it into the standby condition IEC 60417 / Graphical symbols for Use on Equipment 5016 / Fuse Identifies fuse boxes or their locations IEC 60417 / Graphical symbols for Use on Equipment 5008 / “OFF” Indicates disconnection from the mains, at least for mains switches or their positions, and all those cases where safety is involved IEC 60417 / Graphical symbols for Use on Equipment 5007 / “ON” Indicates connection to the mains, at least for mains switches or their positions, and all those cases where safety is involved IEC 60417 / Graphical symbols for Use on Equipment 5104 / Start; start of action Identifies the start button ISO 7010 / Graphical symbols M002 / Refer to -- Safety colours and safety instruction manual / signs -- Registered safety booklet signs Indicates that the instruction manual / booklet must be read ISO 7010 / Graphical symbols -- Safety colours and safety signs -- Registered safety signs Indicates that people with active implanted cardiac devices are prohibited from entering a designated area P007 / No access for people with active implanted cardiac devices ISO 7000 / Graphical 0623 / This way up symbols for use on equipment Indicates the correct upright position of a package IP20 IEC 60529 / Degrees of protection provided by enclosures (IP Code) N/A Protected against solid objects over 12.5mm (e.g., a finger) and no protection against liquids IP21 IEC 60529 / Degrees of protection provided by enclosures (IP Code) N/A Protected against solid objects over 12.5mm (e.g., a finger) and protected against vertically falling drops of water or condensation IP22 IEC 60529 / Degrees of protection provided by enclosures (IP Code) N/A Protected against solid objects over 12.5mm (e.g., a finger) and protected against falling drops of water, if the case is disposed at any angle up to 15 degrees from vertical IP54 IEC 60529 / Degrees of protection provided by enclosures (IP Code) Protected from limited dust ingress. Protected No specific reference no./ from water spray from any direction, limited IP Classification ingress protection Symbol IP55 Standard No./Standard Title Standard Reference No. / Symbol Title Symbol Meaning IEC 60529 / Degrees of protection provided by enclosures (IP Code) Protected from limited dust ingress. Protected No specific reference no./ from water jets from any direction, limited IP Classification ingress protection 21 CFR 801.109 / Prescription Devices Prescription Device Indicates that the product is a medical device and Federal Law (USA) restricts this device to sale by or on the order of a physician Medical Devices Directive 93/42/EEC CE Marking CE marking indicates that a product complies with applicable European Union regulations BS EN 50419, Marking of electrical and electronic equipment in accordance with article 11(2) of Directive 2002/96/EC (WEEE) Crossed out wheelie bin Indicates a product should not be disposed of in a landfill; the black bar indicates that the equipment was manufactured after 2005 Federal Communications Commission FCC Marking FCC marking indicates the electronic device, which sold in the United States, is certified and the electromagnetic interference from the device is under the limits that are approved by Federal Communications Commission N/A Cuff Positioning Indicates the correct positioning for the monitor on the wrist N/A Cuff Positioning Indicates the correct positioning for the monitor on the wrist N/A Artery Marks Types of marks used to indicate the correct positioning of the artery for the upper arm N/A Cuff positioning Indicator on the cuff for left upper arm N/A Cuff Indicator Range pointer and brachial artery alignment positioning indicator on the cuff N/A Cuff Identifier Identifies the type of cuff that is compatible with the blood pressure monitor N/A Cuff Identifier Identifies the type of cuff that is compatible with the blood pressure monitor N/A Arm Circumference Range Indicates the range of arm circumferences to help with selection of the correct cuff size N/A Warnings Various warning symbols to indicate a potentially hazardous situation which, if not avoided, could result in death or serious injury N/A Marking for the position of the replaceable air tube Indicates the position to insert the air tube or
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Has XFA : No XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Create Date : 2017:11:28 10:39:51+09:00 Metadata Date : 2017:11:29 17:14:18-06:00 Modify Date : 2017:11:29 17:14:18-06:00 Creator Tool : Adobe InDesign CS5.5_J (7.5) Page Image Page Number : 1, 2 Page Image Format : JPEG, JPEG Page Image Width : 256, 256 Page Image Height : 256, 256 Page Image : (Binary data 13418 bytes, use -b option to extract), (Binary data 13708 bytes, use -b option to extract) Instance ID : uuid:754eb686-1298-4312-8fa4-a211838aab80 Document ID : xmp.did:F8A20282AACDE7118F9D8510B05C9624 Original Document ID : xmp.did:F8A20282AACDE7118F9D8510B05C9624 Rendition Class : proof:pdf Version ID : 1 History Action : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:F8A20282AACDE7118F9D8510B05C9624, xmp.iid:F9A20282AACDE7118F9D8510B05C9624, xmp.iid:304E3B9EB9CDE7118F9D8510B05C9624, xmp.iid:50E79912CDCDE7118F9D8510B05C9624, xmp.iid:6FA015BE95CEE71190F3E504599268F8, xmp.iid:F4B8718E2FCFE7118738DF8C99E9C698, xmp.iid:B61382B22FCFE7118738DF8C99E9C698, xmp.iid:C94B86F4AED0E711987AEC7B8B0B09D8, xmp.iid:60064904AFD0E711987AEC7B8B0B09D8, xmp.iid:857605D4E4D0E711987AEC7B8B0B09D8, xmp.iid:74B118E2E4D0E711987AEC7B8B0B09D8, xmp.iid:D12E9AFEDCD3E711B7C2FD47AF057F03 History When : 2017:11:20 14:53:09+09:00, 2017:11:20 15:11:16+09:00, 2017:11:20 15:11:16+09:00, 2017:11:20 17:30:32+09:00, 2017:11:21 17:26:59+09:00, 2017:11:22 11:48:01+09:00, 2017:11:22 11:49:02+09:00, 2017:11:24 09:32:30+09:00, 2017:11:24 09:32:56+09:00, 2017:11:24 15:58:08+09:00, 2017:11:24 15:58:32+09:00, 2017:11:28 10:39:37+09:00 History Software Agent : Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5 History Changed : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata Doc Change Count : 737 Format : application/pdf Title : SymbolsGlossary_v1.indd Producer : Adobe PDF Library 9.9 Trapped : False GTS PDFX Version : PDF/X-1:2001 GTS PDFX Conformance : PDF/X-1a:2001 Page Count : 4 Creator : Adobe InDesign CS5.5_J (7.5)EXIF Metadata provided by EXIF.tools