T1 40ToV200MigrationFlyer2x 40 PLC 40S Migration Flyer

User Manual: T1-40 PLC

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadT1-40ToV200MigrationFlyer2x T1-40 PLC T1-40S Migration Flyer
Open PDF In BrowserView PDF
Programmable Logic Controllers

T1-40S PLC Migration
T1 40S PLC

To V200 Series PLC

(TDR116S6S)

V200, CPU + GDI216**S &
GRO216**S I/O Modules
24 Inputs 24 Vdc
14 Outputs Relay
2 Outputs Transistor

24 Inputs 24 Vdc 24
Outputs Relay
2 Outputs Transistor

T1 40E PLC Expansion
24 Inputs 24 Vdc
16 Outputs Relay
24 Inputs 24 Vdc
16 Outputs Relay

V200
Exp I/O
Programming
Cable
Programming
Software
Instruction
Set
Execution
Speed
Networking
Form Factor
Power
Supply
Power
Required
Approvals
Weight CPU
I/O Module

T1 Series
Serial
T-PDS

V200 Series
USB Printer
Cable
1
OIL-DS

T-Series

T-Series

Contact-4 µs
Coil-2.3 µs
Add-6.5 µs
Toshiba
ASCII
ASD Limited
Brick w/ Clipon Modules
120 Vac

Contact-1 µs
Coil-1.1 µs
Add-3.3 µs
2
Modbus
Master/RTU
ASD Full
Modular
w/Clip-on
Modules
24 Vdc

≤ 45 VA

≤ 38 VA

CE, cUL
800 g

CE, cUL
180 g
80 g each

Was an Inexpensive OIS used with the T1-40?
OIS10

OIS15

Replace
with
OIS12

OIS40 PLUS

Notes: 1. The T-PDS software and the OIL-DS
software are very similar. Both use the T-Series instruction set.
2. A Modbus Ethernet TCP/IP CPU module is also available (GPU200*3S).
3. I/O modules also require a 24 Vdc power source.
4. T1-40S PLCs also migrate to the V200 Series.

Instruction Set
Like the T1 Series, Toshiba’s V200 Series PLCs are small type controllers suitable for both
simple relay replacement and complex control applications. The instruction set includes:
♦ Double Length Math
♦ Floating Point Math
♦ Filters, Avgs, & Limits
♦ Conv; Hex↔Bin↔ASCII
♦ Function Generator

♦ Indirect Addressing
♦ For-Next Loops
♦ Subroutine Call
♦ Logic Operations
♦ Jump

♦ PID
♦ Comparisons
♦ Step Sequencer
♦ Interrupt Enable
♦ Log/AntiLog

PLC Order Numbers
TIC_NO
GPU288*3S
GPU200*3S
GDI216**S
GDR288**S
GDD288P*S
GDD288*S
GRO216**S
GDO216P*S
GDO216*S
GAD208L*S
GAA242**S
GDA204**S

DESCRIPTION
CPUs
V200 CPU, 8 Inputs 24 Vdc, 2 Outputs 24 Vdc Transistor, 6 Outputs Relay, Requires 24 Vdc PS.
V200 CPU, Ethernet & USB Port, Requires 24 Vdc PS.
I/O Modules
16 Inputs, 24 Vdc, 8p/com, sink/source
8 Inputs, 24 Vdc. 4p/com, 8 Outputs Relay, 4p/com
8 Inputs, 24 Vdc. 4p/com, 8 Outputs PNP, 4p/com
8 Inputs, 24 Vdc. 4p/com, 8 Outputs NPN, 4p/com
16 Outputs Relay, 8p/com
16 Outputs, 24 Vdc Transistor, 8p/com, PNP
16 Outputs, 24 Vdc Transistor, 8p/com, NPN
8 Analog Inputs, 4‐20 mA, 0‐10 Vdc (12 bit)
4 Analog Selectable Inputs, 4‐20 ma, 0‐10 Vdc, 0‐50/100 mV, RTD, TC ‐‐ 2 Analog Outputs, 4‐
20 mA, 0‐10 Vdc.
4 Analog Outputs, 4‐20 ma, 0‐10 Vdc.

Notes: 1. More analog and communications modules under development.
2. See OIS PLUS flyer for OIS PLUS part numbers.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : jolner
Create Date                     : 2011:12:06 05:44:21-06:00
Modify Date                     : 2013:09:18 14:40:20+02:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Title                           : Microsoft Word - T1-40ToV200MigrationFlyer2.docx
Creator                         : jolner
Producer                        : Acrobat Distiller 9.4.6 (Windows)
Document ID                     : uuid:87abde53-0697-4f0f-8d07-728ea703da69
Instance ID                     : uuid:ab3dbe35-1c47-40d3-a524-3df0ed1d02ad
Page Count                      : 2
Has XFA                         : No
EXIF Metadata provided by EXIF.tools

Navigation menu