T2500_Reference_Cards T2500 Reference Cards
User Manual: T2500_Reference_Cards
Open the PDF directly: View PDF .
Page Count: 4
Download | ![]() |
Open PDF In Browser | View PDF |
Command Summary (continued) Command Summary Convnand Parameter Conventional Command Mode You may enter a command line of up to 80 characters in upper or lower case with the {lrSt command in the line preceded by an "AT" or" at" and the last command followed by a carriage return. A Answer AI Repeat previous command B(n) Oor 1 D(n) O-g, A-D,',# Dial number Mod~iers: W Wail lor dial tone P Pulse dialing T Tone dialing Timed wait I In~iate momentary on-hook flash @Wait for quiet answer R Sw~ch to answer mode when remote modem answers ; Remain in command mode after dialing S_n Reference a number in number directory You can repeat the last command line issued by entering" Af or "a/". Do not enter the "AT' prefix when using this command. Result Codes Numb"" M.ssage and Oaecrlptlon 0 OK - The command was successfully completed. 1 CONNECT -Connected at 300 bps interface speed. 2 RING - An incoming ring has been detected. 3 NO CARRIER - Time to connect has expired or carrier lost. 4 ERROR - A command error has been encountered. IDefault Access Character Used to enter commands which are not normally available in Conventional Command Mode. All commands following a "-" character to the end of the command line are interpreted in Enhanced Command Mode. ~ T2500 Quick Reference Card The notation "(n)" in the descriptions represents a decimal numeric option, and "(x)" represents an assigned value. Theparentheses should not be typed. If a command is typed without a value when one is expected, the modem will assume a value of O. The option should immediately follow the command. For example, to turn off the result codes, type Ql not Q=l. The use of the "=" is explained under the S command in your Reference Manual. Deecription Bell Mode Selection CCITI (V.21 or V.22) 1 Bell (103.1 or 212A) o Oor 1 Echo Command ON/OFF F(n) 1 Echoplex ON/OFF Not supported 1 No echo o Off Description N(n) o or 1 Transmission Speed Negotiation Connection speed must match value specified by 537 1 Allow speed negotiation to maximum spec~ied by 537 O(n) o or 1 On-Line Place modem in data mode 1 Place modem in data mode and in~iate retrain Q(n) 0-2 Quiet Enable Modem returns result codes 1 Result oodes disabled 2 Resu~ oodes returned when originating a call but not when answering a call S(n)-(x) CONNECT 1200- Connected at 1200 bps interface speed. S NO OIALTONE - No dial tone was detected. 7 BUSY - Remote connection is busy. 8 NO ANSWER - Five seconds of silence was not detected within 30 seconds when an @ ~fierwas encountered in the dial string. H(n) I(n) 10 CONNECT 2400 - Connected at 2400 bps interface speed. 11 CONNECT 4800- Connected at 4800 bps interface speed. 12 CONNECT 9600 - Connected at 9600 bps interface speed. 14 CONNECTI92OO-Connected at 19200bpsinterface speed. 40 CARRI ER 300 - Carrier detected at 300 bps (Belli 03 mode). 46 CARRI ER 1200 - Carrier detected at 1200 bps (Bell 212A or V.22 mode). 47 CARRIER 2400- Carrierdelected at 2400 bps (V.22bis mede). 50 CARRIER 9600 - Modem is operating in PEP mode. 70 PROTOCOL: NONE - Error control is not being used. 71 PROTOCOL: ERROR-CONTROLlLAP-B - PEP or MNP error control is being used. o Nl o QO o Read contents of register n V(n) Oorl Verbose ON/OFF Return numeric response 1 Return English response VI WIn) Oorl Negotiation Progress Reporting Progress not reported 1 Progress reported WO X(n) 0-4 Result Code and Dialing Capabilities See Refemnce Manual X4 El YIn) o or 1 Disconnect on Break Modem ignores break 1 Modem disconnects on break YO Fl Z(n) 0-1 Reset Reset and recall profile A 1 Reset and recall profile B 1 On 5 o Set register n to value x SIn)? , E(n) Parameter Bl Pulse lcJiaing 1Default Command o o o o o or 1 Hook ON/OFF Hang up (on-hook) 1 Pick up phone line (off-hook) &C(n) o or 1 Data Carrier Detect Control DCD always on 1 DCD on when carrier detected CO 0-2 Informalion Return product 10 oode 1 Return 3 dig~ number 2 Return OK resul! oode &D(n) 0-3 Data Terminal Ready Interpretation Modem ignores DTR 1 Modem enters command mode when DTR is dropped 2 Modem disconnects and enters command mode when DTR is dropped 3 Modem resets and enters command mode when DTR is dropped DO &F 0-3 Recall Factory Parameters See Refemnce Manual &G(n) 0-2 Guard Tone Selection No guard tone 1 550 Hz guard tone 2 1800 Hz guard tone o o l(n) 0-3 Speaker Volume Low 1 Low 2 Medium 3 High l2 M(n) 0-3 Speaker ON/OFF Speakeroff 1 Speaker on while connecting 2 Speaker always on 3 Speaker on after dialing until carrier detected Ml o o o o o &GO Command Summary (continued) Command &J(n) &K(n) Parameter a 0,3-5 Deecription I Jack Type Selection RJ-l1jack 1 AlA 1 control selected a Flow Control No flow control 1,2 Reserved 3 RTS/CTS Flow Control 4 XON/XOFF Flow Control 5 Transparent XON/XOFF a Default &JO &K3 Register &M(n) &P(n) &O(n) &R(n) Oor 1 Answer on Ring Number SI 0-255 Count of Rings S2 S4 0-3 Oor 1 0-5 &lO Communicatioos Mode Selection Asynchronous Mode 1 Synchronous Mode 1 2 Synchronous Mode 2 3 Synchronous Mode 3 &MO Pulse Dialing Make/Break Ratio 39% make, 61% break 1 33% make, 67% break &PO Communicatioos Mode Selection Sameas&MO 1 Same as &Ml 2 Sameas&M2 3 Sameas&M3 5 Asynchronous, Error Control Mode &05 RTS/CTS Signal Interpretation CTS goes ON with RTS 1 RTS ignored, CTS ON when modem ready for receiving &Rl a a a a a or 1 a S6 &S(n) Oor 1 Data Set Ready Interpretation DSR is always ON 1 DSR ON when modem is coonected and ready &SO &T(n) 0-8 Inftiate Test Function See Reference Manual &T4 &V &W(n) &X(n) a 0-2 Wrfte Configuration Parameters Save to profile A 1 Save to profile B a Synchrooous Transmit Clock Source a Modem generates signal 1 DTE generates signal 2 Signal derived from incoming data signal (slave operation) &Y(n) &Z(n)-(x) 0-255 Oar 1 Defauij User Profile Selection Recall profile A after power up 1 Recall profile B after power up 0-3 Set Number Directory a Default 0 Escape Character (ASCII) 43 0-97,123·127 Carriage Return Character (ASCII) 0-255 0-97,123-12 2 -255 S7 1 -255 S8 13 line Feed Character (ASCII) 10 Backspaos Character (ASCII) 8 Dial Tone Wait Time (seconds) 2 Wait for Carrier TIme (seconds) 30 0-255 Pause Time for Comma (seccnds) 2 S9 1 -255 Carrier Detect Time (100 ms unfts) 6 S10 1 -255 Carrier loss to Disconnect Time (100 ms unfts) 14 S11 50 - 255 Touch Tone Timing (milliseconds) 95 S12 0-255 Escape Sequence Guard Time (1/50 second unfts) 50 S18 0-255 Test Termination Timer S25 0-255 DTR Delay Timing (10 ms unfts) 5 S26 0-255 RTS to CTS Delay Interval (100 ms unfts) a S36 a or 1 Negotiation Failure Treatment If error control oonnection cannot be made disconnect 1 If error control connection cannot be made fall back to non-error-control mode 1 S37 0-9 Transmission Mode Connect at last AT speed 1-3 300 bps (Bell 103 or V.21) 5 1200 bps (Bell 212A or V.22) 6 2400 bps (V.22bis) 7 PEP mode 9 PEP mode a S38 0-255 I a a Vi_ Active Configuration and User Profiles See Reference Manual Oor 1 Description 0-255 S3 line Type Selection Dial-up line 1 leased line Range SO S5 &l(n) ASCII Code Chart Register Summary Delay Before Disconnecting 0 2OCC~ OEC~ &XO Mnern NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI OLE OCI OC2 OC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US Dec Hex Code Dec Hex 00 01 02 03 00 01 02 03 SP I 04 04 05 06 07 06 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 05 06 07 06 09 $ % 25 26 27 28 29 30 31 OA OS OC 00 OE OF 10 11 12 13 14 15 16 17 18 19 lA lB lC 10 IE IF • & ( 1 + I 0 1 2 3 4 5 6 7 8 9 ; < > ? 32 20 33 21 34 22 35 23 36 24 37 25 38 26 39 27 «l 28 41 29 42 2A 43 2B 44 2C 45 20 46 2E 47 2F 46 30 49 31 50 32 51 33 52 34 53 35 54 36 55 37 56 38 57 39 58 3A 59 3B 60 3C 61 30 62 3E 63 3F Code Dec Hex @ 64 A 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 63 B C 0 E F G H I J K L M N 0 P a R S T U V W X Y Z I . \ I - «l 41 42 43 44 45 46 47 46 49 96 a b c d e f 9 h i 4A j 4B k I m n 4C 40 4E 4F 50 51 52 53 64 54 85 55 86 87 86 89 56 57 58 59 90 SA 91 58 92 5C 93 50 94 5E 95 Code Dec Hex SF 0 P q r s 1 u v w x Y z I I } - DEL 97 98 99 100 101 102 103 104 105 106 107 106 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 60 61 62 63 64 65 66 67 68 69 SA 6B 6C 60 6E SF 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 70 7E 7F Command Summary T2S00 Quick Reference Card Enhanced Command Mode You may ent.r a command ine of upto 80 charecters in upper or lower case with the first command in the line preoeded by an "AT" or "at" and the last oommand followed by a carriage retum_ Note that Hthe S63 register is set to 0, you should not enter the "AT" atth.beginning 01 the command fine. The notation "en)" in the descriptions represents a decimal numeric option, and "(x)" represents an assigned value. Theparenthesesshould notbetyped. Ha oommand is typed without a value when one is eocpected, the modem wil assumea value of O. The option should immediately follow the oommand_ For example, to turn off the resuft oodes, type 01 not 0-1. The use of the'" is explained uncler the S oommand in your Reference Manual. Number .....1IlI.1I1d Deec:rlptlon 71 72 73 CONNECT FASTIKERMICOMP-PEPconnection with Kemit aJppori and data co....l888ion enabled. CONNECTFASTIXM>MICOMP-PEPconnectionwithXmodam aJppori and data co....l888ion enabled. Command A C(n) 1 CONNECT3OO-Connectedat3OObps(8e1l103Compatible). 2 RING -AnincolTing ring hssbeendetectad. 3 NO CARRIER-Time1l>connecthasexpiredorcarrie.1oat 4 ERROR-A command .,rorhasbeen encountared. 5 CONNECT 1200-Con..aed at1200bps(8e11212A or 6 V.22C~Ie). Oorl D(n) BUSV-RemoIeconnectionisbusy. 8 NOANSWER- Fi.. secondeof oilencew... not detected within 30 seconds when ",,@mocifierwasencounteredinthedalstring. 10 CONNECT2400-Con..aed8l2400bps(y.22bisCo!l1>8lible). i E(n) Oorl Echo Command ONIOFF o Off F(n) 0-2 G H(n) I(n) Echcplex ONIOFF o On 1 Off 2 On plus lineleed after carriage return Oorl Read oontents 01 register n U Update System Password Oorl 0-6 CONNECT FAST-Connectedto a modem using the Pac:kotized En..mblePI01DcoI(PEp). 62 RRING-Remoleconnecton i.ringing. 20 CONNECT3OClIREl.- MNP connection 81300 bps. 22 CONNECT12OO1REL-MNPconnedionat1200bps. N(n)_(x) 0-9 Set Number Directory 23 CONNECT24001REL-MNPconnection .t2400bps. N(n)? 0-9 Display Number 24 CONNECT48OOIREL-MNPconnedionat4800bps. N? 0-9 25 CONNECT96OOIREL-MNPconnec1ionat9600bpa. 6t CONNECTFASTIKERM-PEPconnedionwithKemit ..pport. 62 CONNECTFASTIXMOM-PEPoonnec1ion withXmodam ..pport. 0-3 0 O(n) 0-9 Speaker ONIOFF o Spaakeroff 1 Spaaker on while oonnecting 2 Spaaker always on 3 Speaker on after dialing until carrier detected Vl Oorl Negotiation Progress Reporting o Progress not reported 1 Progress reported WO X(n) 0-3,10-14 Resuft Code BasiclExtsnded o Basic resuftcodes 1 Extended resuft codes 2 MNPresuKcodes 3 MNP and PEP resun codes 10-14 Conventional resuft oodes XI ECM X14ca V(n) Zln) Oorl 0-2 &B &E(n) Information o Retum product 10 code 1 Retum diagnostic status 2 Retum current transmission mode 3 Retum firmware version level 4 Retum negctialed register values CONNECT9600-Connectat9600bps(y.32 Mode). M(n) Fl Verbose ONIOFF o Retum numeric response 1 Retum English response Wen) El Hook ON/OFF o Hang up (on-hook) 1 Pick up phone line (off-hook) 50 CONNECTFASTICOMP-PEPconnedionwithd8laCO"1'IMIion. Sen)? Yen) Reset o Reset and recall defauftprofil 1 Reset and recafl profile A 2 Reset and recall profile B 0-2 A8nge ~ SO 0-256 Ans_ on Ring Numbe. Sl 0-256 Cotnt of Rings S2 0-256 Escape Character (ASCII) 43 S3 0-96, 123-127 Carriage Retum Character (ASCII) 13 0-2 &R(n) Oorl Force Retrain or Renegotiate o Retrain 1 Renegctiale Display Number Directory and S-registers &T(n) 0-8 Initiate Test Function See Relerence Manual On-Line Place modem in data mode &W(n) 0-2 Write Configuration Parameters o Save to delauK profile 1 Save to profile A 2 Save to profile B Remote Modem Aoosss l-ECM\ O-OCM 84 0-255 Line Feed Character (ASCIQ 10 0-96, 123-127 Backspace Character (ASCII) 8 S6 2-255 Dial Tone WU Time (seconds) S7 1-255 Wait for Carrier Time (seconds) S8 0-255 Pause Time for COmma (seconds) 2 S9 1-255 Carrier Detect Time (lOOms un~s) 6 S10 1-255 Carrier Loss to Disconnect Time (lOOms un~s) 2 4O-ECM 3O-CCM 7-ECM 14-COM S11 50-255 Touch Tone Timing (milliseoonds) S12 0-255 Escape Sequence Guard Time (1/50 second unb) 50 S18 0-255 Test Termination Timer 0 S25 0-255 DTR Delay Tming (10 ms unu) 5 S26 0-255 RTS to CTS Delay Interval (l00msunu) 0 S38 0-255 Delay Before Disconnecting 7O-ECM IS-COM o-ECM 20.(lCM 841 0-255 Inactivity Timer (tenths 01 hours) 0 S45 oor 255 Remote Access Enable o Disable Remote Aocess 255 Enable Remcte Access 0 S46 0-3 ~I~:::~ritydisabled 0 1 Calback security enabled 2 CaIback secu~ enabled with ~sword rave . ication 3 ass through secur~y enabled, no caUback initialed Display EEP ROM Paramaters o Display defauK prolile 1 Display profile A 2 Display profile B Pulse Dialing MakelBreak Ratio o U.S. timng 1 U.K. timing DmuIt S5 ZO Use EEPROM Parameters o Recall delauft profile 1 Recall profile A 2 Recall profile B Oorl % RegJater Recall Factory Parameters See RelerenceManual Ml 05 YO Blind Command &F &N(n) Disconnect on Break o Modem ignores break 1 Modem disoonnects on break &P(n) Ouiet Enable o Retum resuftcodeforboth local and remote mcdems Def8ul Set register n to value x GctoVoioe CONNECT4800-Connected at4800bpa (y.32fallback). 70 S(n)-(x) 1 On 11 CONNECTFASTIUUCP-PEPoonnection with UUCP ..pport. Pulse dalng Deectlptlon Register Summary 1 Retum reauft oode for remote mcdemonly 2 Retum resuft cod. for local mcdemonly 3 Do not return resu. code for e~her local or remote mcdem 4-9 Partial quiet modes (see your Referenoe ManuaQ o Off 12 63 ParMM1lr Tum Carrier ONIOFF 0-9,A-D, -,. Dialnumber Modifiers: W Wait for dial tone N Referenoe number in number directory P Pulse dialing T Tone dialing Timed wait In~iate momentary on-hook flash @Waitforquietans_ R Switch to answer mode when remote modem ans_s : Remain in oommand mode after dialing \ Referenoe a number in number directory NO DIAL TONE-No dal1Dnewas detectad. 7 Command O(n)Conrc 1 On The following resuft oodes are retumed when the X command setting is XC through X3. Hthe X oornrnand setting is Xl0 through X14, Conventional Command Mode resu. oodes are returned. OK-ThecommandwaaauccessfullrCO"1'ietad. DmuIt Repeal previous command CONNECTFASTIUUCPiCOMP-PEPconnedion with UUCP aJpporiand dataco....l888ion enabled. Result Codes 0 Deecrlplion Answer AI You can repeal the last oommand line issued by entering"AI" or "ar. Do not enter the "A1"" prefix when using this command_ Number Meeeage and Ducrlptlon PerMM1lr Command Summary (continued) PO - 847 0-256 DSRlDCD Delay Time (50 ms unu) 4 S48 00.1 Eight Bit Comparison o Compare lower seven b~s only 1 Compare all eight b~s 0 S49 Oorl Product Identification String o 10 returns 96X 10 code 1 10 returns 123 10 code 0 S50 0-3, 254,255 Transmission Mode o Auto Speed Determination 1 300 bps (Bell 103) 2 1200 bps (Bell 212 A or V.22) 3 2400 bps (V.22bis) 254 Use last AT oommand speed 255 PEPmcde O-EOM 254-CCM S51 0-5,252 254,255 Interface Speed o 300bps 1 1200 bps 2SS-EOM 252-CCM T4 Register Summary (continued) Register Summary (continued) Reg..... Jhnge 2 3 4 5 252 254 255 851 confd 852 854 DeKripIIon 0-4 0-4 Detallt 865 2400bpa 4800bps 9600bpa 19200bps Autobaucl (no type-ahead) Autobaucl (19200 bps delauft) AutobaucI (9600 bps de/aul) DTR Interpretation o DTR.::lnored 1 The em discomects and disables auto-ans_r if DTR is not present 2 The modem discomects and reloadsoper~ parameters if DTRis d ,andwillnot auto-answer if DTR is not present 3 Modem enters command mode wnen DTR is dropped 4 Modem nangs up and enters command mode when DTR is dropped Break8~n~lnterp~On See Refer8noe Manual 866 867 868 o-ECM 3-CCM 0-3 Escape Cnaracter/Sequence Interpretation See ReffHetIce Manual 0 856 0-255 XON Cnaracter (ASCI~ 17 857 0-255 XOFF Character (ASCII) 19 856 0-7 Flow Control Used by DTE o Noflowcontrol 1 Use RTSlCT8 flow control in half duplex mode 2 Use RT8 flow oontrol in full duplex mode 3 Use XON/XOFF protocol 4 Use both XONIXOFF and RT8 flow control 5 Use ENQlACK protocol 6 Use both ENO/ACK and XONIXOFF protocol 7 Use transparent XONIXOFF 0-255 P~ Character (ASCI~ 0 861 0-255 8peaker Volume 0 Speaker is all 1-99 Low volume 100-199 Medium volume 2ClO-255 Hignvolume 150 Break Length TIme (150 ms units) 3 863 864 0-2 Oorl Command Mode Selection o Enhanoed Command Mode AT prelix not allowed 1 Enhanoed Command Mode AT prefix required 2 Conventional Command Mode DiaVAnswer 8equence Abort o Abort dial/answer sequenos if character sent by DTE before connection is established 1 Ignore characters sent by DTE while dialing or ans_ring a call Deecriptlon Oorl XON/XOFF Failsafe o No~ XONIXOFF flow control 1 Reissue XOFF if DTE does nd suspend data transrrissions 0-2 869 Oorl Lock Interface Speed o Change speed to match connection, no flow control 1 Lock speed, use flow control 2 Lock speed , use flow control if MNP oonnection established CT8 Interpretation o CT8 is on when modem is ready to aocept data 1 CT8 turns on 200 ms after RT8 goes active 0,2-6,255 Flow Control Used by DCE o No flow control 2 Use CT8 flow control in fun duplex mode 3 Use XONIXOFF protocol 4 Use both XONIXOFF and CT8 flow control 5 Use ENQ/ACK protocol 6 Use both ENO/ACK and XONIXOFF protocol 255 Use flow control specified by 858 0-2 3-ECM 2-CCM 859 2-255 R8IIge 0 855 862 Reg...... XON 8~~ Hand~ng o X N processed, not passed on 1 XON processed, passed on 2 See Reference Manual 870 Instantaneous Transmit Rate 871 TransmK B~s Per Channel 872 Instantaneous Reosive Rate 873 Reosive BKa Per Channel 874 Reosived Packets Retransmitted 875 Packets Aa:epted 876 Equivalent Une Noise Profile 8n Frequency Offset 876 810w Mode Line OuaiKy Register Summary (continued) Defallt 0 S95 Deecrlpllon Oorl TransmissOn 8peed NegotiatOn 0 Use speed specified by 850 register only 1 Negotiate speed to maximum specified by 850 register 2 FaUback within a specified mod sccheme only 3 Use appropriate fallback 0-2 0 255 0 MNPOperaiingMode 0 No~ mode - MNP disabled 1 MNP reliable mode 2 MNP autoreliable mode Register Summary (continued) Detallt 8110 o-ECM 2-CCM Oorl MNP Data Compression Enable 0 Disable data compression 1 Enable data compression 0 897 0-1 V.42 LAP-M Enable 0 Disable LAP-M 1 Enable LAP-M 0 V.42bis Data Compression 0 No data compression 1 Data compression in trasmitt dinaction only 2 Data compressOn in receive dinaction only 3 Data compression in both transmK and reosive dinactions 3 Reverse AnswerlOriginate Mode 0 8100 O,1,2,or3 Oorl o No~mode Reg..tar Ringe 8111 0-1,255 8102 V22 Mode Enable o 212A Emulation 1 V22 Emulation 0 891 0-2 Guard Tone Selection o No guard tone 1 1800 Hz guard tone 2 550 Hz guard tone 0 892 0-2 Answering Sequenos 8e1ection o Nor~ search sequence 1 PEP answer tones last 2 No~ search sequenos but preceded by V.25 answer tone 0 893 3-255 V.32 AC Transmit Duration (100 ms unb) 8 0-4 0-2 SDLe Register Summary (Optional) Detallt 0 0-255 Kermit MarkCharacter (ASCII) 1 Oorl Echo 8uppressor Compensation o Disable echo suppressor corJ1)8nsation 1 Enable echo suppressor corJ1)8nsation 0 8130 0-6 Data Set Ready Interprolation o D8R is always on 1 OSR is turned on when answer tone is detected 2 OSR is on when modern ready 3 OSR on when modem ready Hcarrier is lost, OSR turns off fortimospecified byS47 4 D8R on when modem off-hook 5 D8R is turned on when carrier is dolected 6 OSR follows DTR Auxiliary Telco Lead Settings (RsckmountandSDLC ..raiononly) 0 ~nore auxiliary leads 1 se AlAI function 2 Use MVMIC function 0 8104 0-4 Automatic Dialing Options See Re/erenos Manual 0 8105 0-2 TID 8wKch EnablelDisable 1 0 Disable the TID swKch 1 Enable the TID switch 2 Enable TID swKch only when modem is off-hook 8106 Oorl V.42 Detection Enable o Modem will not perform detectio 1 Modem will perform detection of V.42 mode 0 8107 0-255 Detection TImer 20 8108 0-1 V.42 Match Count o Match count is 4 1 Match count is 1 0 0-2 Synchronous Dial Command Sol Enable 0 Disable 8ynch Dialing 1 Enable IBM 4941 2 Enable V 24bis 8222 0-255 Enhanced Command Mode Acosss Character (ASCI~ 8255 0-2 Defaun User Profile 8e1ection 0 RecaA profile specified by AlB switch. 1 Recall profile A after power on Detallt Asyno'SDLC Mode Selection o Asynchronous Mode 1 8OLCMode 2 Transpanont 8ync Mode 3 Asyno'Sync Mode 0 8151 1-5 80LC Interface Speed 1 1200 bps 2 2400bps 3 4800bps 4 9600bps 5 19200bps 4 8152 0-2 80LC SwKchedlNonswKched o Nonswitched Mode 1 SwKched Mode 2 8pecial SwKched Mode 1 8153 Oorl 80LC FulVHaIf Duplex o Full Duplex Mode 1 Half Duplex Mode 1 8154 00r2 80LC Clock Options o Use DCE clocking 1 Use DTE clocking 2 Use DCE clocking 0 8155 Oorl 80LC NRZlNRZI Data Enooding o UseNRZenooding 1 Use NRZI enooding 0 O-CCM 0 DeKripIIon 0-3 2-ECM Data Carrier Detected Interpretation O-CCM 2-ECM o DCD is always on 1 DCD is turned on when carrier is detected 2 DCD is on when modem ready 3 DCD on when modem ready Hcarrier is lost, D8R turns off fortimospecified byS47 4 The DCD sign~ will be the inverse of the CT8 sign~ 8169 Ringe 8150 255 8121 0-4 Reg.tar 255 8112 8131 Continuous AnswerlOriginate o Connect no~1y 1 Attempt to connect as answer modem every 20 seconds 2 Attempt to connect as originate modem every 20 seconds 3 Immediately attempt to connect as answer modem 4 Immediately attempt to connect as originate modern PEP 0aIa Compression Enable o Disable data oompression 1 Enable data compression 255 Enable data compression only if remote modem's 8110 register is set to 1 0,10-14, File Transfer Protocol 8upport 20,30,255 See Reference Manual 1 Reverse mode 8101 Deecriptlon 1 896 898 Oorl 0 894 R8llge o-ECM 2-CCM 890 l-ECM 2-COM Register 8157 0-255 80LC Disoonnection Delay TIme 0 8158 0-255 80LC D8R Delay Time 0 8160 0-255 80LC Frame Retransrrit Limit 10 8161 0-255 80LC Devioo TImeout 20 8162 0-255 SOLC Nonproductive TImeout 2 8163 0-255 80LC Retransmit TImeout 3 8164 1-32 80LC Primary Poll Rate 7
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-21:37:19 Create Date : 2017:09:04 16:56:45-08:00 Modify Date : 2017:09:04 17:05:11-07:00 Metadata Date : 2017:09:04 17:05:11-07:00 Producer : Adobe Acrobat 9.0 Paper Capture Plug-in Format : application/pdf Document ID : uuid:91114a23-b6c5-ce4d-a25f-d49e74045572 Instance ID : uuid:26e37d47-5f5d-a549-a208-02dacaa04e98 Page Layout : SinglePage Page Mode : UseNone Page Count : 4EXIF Metadata provided by EXIF.tools