Override knob located upper right corner.
Timer resumes regular schedule at next tripper
To override permanently, remove trippers
Install trippers on dial.
Manually rotate dial two times to see how load turns on-off.
Set trippers at selected on-off times
Rotate dial until current time lines up with white arrowhead located on inner dial.
Timer dial rotates as time passes. Tripper pushes on-off lever.
If dial does not rotate, then check incoming voltage, replace timer with new timer.
Product name TB 118 /178 timer switch15 amp load
Specification of TB118:
Type TB118
Working voltage 100-240VAC common use
Allowed voltage range 85-264VAC
Power supply frequency 50Hz/60Hz common use
Drive way Quartz motor type
Power cut compensation Within 300Hrs (with nick-chrome battery inside)
Timer precision Difference of month: within15 min (temperature: 25
Active time precision Within 7.5 min (excluding adjustment error at initial stage)
Period 24Hrs
Electric-consumed 110VAC 1W 220VAC 2W
Output Circuit No. One circuit
Circuit composing Same circuit (with voltage terminal input)
Contact composing Single pole single inlet
Auto open/ close Attached with ON/OFF switch
*Contact capacity Resistance 15A
incandescence 15A
Resist (cosΦ=0.7) 12A
Motor (cosΦ=0.7) 110VAC 750W 220VAC 1500W
Time setting Method Fixed handle inserted, trip type
Min. unit 15min
http://waterheatertimer.org/How-to-wire-TB118-TB178-timer.html