THq Manual
User Manual:
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
THq Digital Tissue Homogenizer User Manual OMNI THq This manual is a guide for the use of the Omni International THq, Digital Tissue Homogenizer and accessories. Data herein has been verified and validated. It is believed adequate for the intended use of the instrument. If the instrument or procedures are used for purposes over and above the capabilities specified herein, confirmation of the validity and suitability should be obtained, otherwise Omni International does not guarantee results and assumes no obligation or liability. This publication is not a license to operate under, or a recommendation to infringe upon, any process patents. Notes, cautions, and warnings within the text of this manual are used to emphasize important and critical instructions. This Omni International product is warranted to be free from defects in material and workmanship for a period of THREE YEARS from the date of delivery. Omni International will repair or replace and return free of charge any part which is returned to its factory within said period, transportation prepaid by user, and which is found upon inspection to have been defective in materials or workmanship. For the first 90 days, both parts and service are without charge. For the balance of the period, parts will be provided but service will be charged at established labor rates. This warranty does not include normal wear from use; it does not apply to any instrument or parts which have been altered by anyone other than an employee of Omni International nor to any instrument which has been damaged through accident, negligence, failure to follow operating instructions, the use of electric currents or circuits other than those specified on the plate affixed to the instrument, misuse, or abuse. Omni International reserves the right to change, alter, modify, or improve any of its instruments without any obligation whatsoever to make corresponding changes to any instrument previously sold or shipped. THE FORGOING OBLIGATION IS IN LIEU OF ALL OBLIGATIONS AND LIABILITIES INCLUDING NEGLIGENCE AND ALL WARRANTIES OF MERCHANTABILITY OR OTHERWISE, EXPRESSED OR IMPLIED IN FACT OR BY LAW, AND STATE OUR ENTIRE AND EXCLUSIVE LIABILITY AND BUYERS EXCLUSIVE REMEDY FOR ANY CLAIM OF DAMAGES IN CONNECTION WITH THE SALE OR FURNISHING OF GOODS OR PARTS, THEIR DESIGN, SUITABILITY FOR USE, INSTALLATION, OR OPERATION. OMNI INTERNATIONAL WILL IN NO EVENT BE LIABLE FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES WHATSOEVER, AND THEIR LIABILITY UNDER NO CIRCUMSTANCES WILL EXCEED THE CONTRACT PRICE FOR THE GOODS FOR WHICH LIABILITY IS CLAIMED. - READ ALL INSTRUCTIONS BEFORE USING. The Omni THq has been engineered for economical functionality as well as safety; however, basic safety precautions and common sense must always be demonstrated when using any electrical product. DO NOT attempt to modify any part of the Omni THq. If you experience problems with or have questions about your Omni THq, contact your authorized dealer or call Omni International at 1-800-776-4431 or 1-770-421-0058. - DO NOT allow the machine to be submerged in any liquid. - DO NOT use in any setting other than an indoor laboratory. - DO NOT plug power cord into an incorrect outlet. To reduce the risk of burns, electrocution, fire, or injury: - Use this product only for its intended purpose as described in this booklet. DO NOT use attachments not recommended by the manufacturer. - DO NOT operate the product if it is damaged in any way. - Keep this product away from heated surfaces. WARNING: The tip of the saw tooth generator probe is sharp. WARNING: Reduce the risk of unintentional starting; make sure that the power switch is in the OFF position prior to plugging in the unit. WARNING: DO NOT process pathogenic material in an open container, since aerosols created during normal processing could be inhaled by the operator. Please call for assistance in processing pathogens or other material which require sealed enclosures. WARNING: Keep all housings in place and in working order. WARNING: Remove all tools from the generator probe before turning the motor on. WARNING: DO NOT use the motor in a dangerous environment. WARNING: Disconnect the motor before servicing, and when changing the generator probe. WARNING: DO NOT modify the plug or cord that is provided. If the plug will not fit the outlet, have the proper outlet installed by a qualified electrician. WARNING: Reduce the risk of unintentional starting; make sure the power switch is in the OFF position before plugging in the motor. WARNING: Damaged or worn power cords should be repaired or replaced immediately by a qualified electrician. WARNING: Improper connection of the equipment can result in a risk of electric shock. DECONTAMINATION Should an instrument or component that has been used with radioactive or pathogenic material require factory or field service, comply with the following procedure to ensure the safety of service personnel: Clean the parts to be serviced of all encrusted material and decontaminate them. There must be no radioactivity detectable by survey equipment. Obtain a Decontamination Certificate from Omni International. Complete the certificate and attach to the instrument or parts being returned. If no Decontamination Certificate is attached, and a potential radioactive or biological hazard is detected or suspected by Omni International, the equipment will not be serviced until proper decontamination and certification is complete. The sender will be contacted for instructions as to the disposition of the equipment. Disposition costs will be borne by the sender. WARNING: It is a violation of federal law to transport biologically hazardous or radioactive materials without proper packaging, labeling, and appropriate warnings. Should this product ever require service, please contact Omni International at 1-800-776-4431 Overview OMNI THq 1 5 2 6 3 7 4 8 1. Power cord port 2. Run/Stop LED indicators 3. Power 4. Generator Probe coupling Clamp 5. Digital Readout Screen 6. Run button 7. Stop button 8. Increase/Decrease RPM The Omni THq consists of the following: 12-118 Description Part Number Quantity Motor Drive Unit 12-200-1 1 Clamp 12-118 1 Tool Kit T1001 1 Soft Tissue Omni Tip 30007L 6 Hard Tissue Omni Tip 30007HT 6 Instruction Manual 03-225 1 Optional Stand Available (sold separately) - Order No. S1000 Stand Mounting Clamp Release Button Push to lock into Clamp 1. Slide the THq motor into the opening on the end of the post clamp assembly and push it down firmly. The unit will lock in place. Clamp 12-118 2. To release the THq, press the black button on the back of the opening of the post clamp assembly and lift the motor from the cradle. Stand 3. Slide the post clamp assembly down over the end of the post until the clamp is at the desired height and lock in place. S1000 (sold separately) Generator Probes and Omni TipsTM 1. Insert Generator Probe into coupling 2. Quarter turn clockwise to lock 3. Ready to use *always submerge probe in liquid before starting 1/4 Turn *Never run dry IMPORTANT INFORMATION The blue cap must be removed from the end of the generator probe before operating. 1. 2. 3. Ready to homogenize. Stainless Steel Generator Probes Omni Tips® Plastic Disposable Generator Probes Size Processing Range Order No. 5 mm x 75 mm .2 mL - 5 mL B5-075 5 mm x 75 mm (6 pack) .2 mL - 5 mL B5-075-6 7 mm x 110 mm .25 mL - 30 mL B7-110ST 7 mm x 110 mm (6 pack) .25 mL - 30 mL B7-110ST-6 10 mm x 110 mm 1.5 mL - 100 mL B10-110ST 10 mm x 110 mm (6 pack) 1.5 mL - 100 mL B10-110ST-6 Type Hard Tissue Soft Tissue Size Quantity Order No. 7 mm x 110 mm 25 Pack 30750H 7 mm x 110 mm 50 Pack 32750H 7 mm x 110 mm 25 Pack 30750 7 mm x 110 mm 50 Pack 32750 Operation 1. Run button 1 2 3 4 5 2. Stop button 3. Increase RPM 4. Decrease RPM 5. Power button General Operation Power - Plug in the power cord and press the power button Set Speed - Adjust speed using the Increase/Decrease speed buttons Start - Press the Run button Stop - Press the Stop button Troubleshooting PROBLEM CORRECTIVE ACTION The THq is plugged in and turned on but is not functioning. - Check power cord connectors - Check wall socket for power to the outlet Teflon bearing wears quickly - Fluid level in the sample may be too low - Immerse the probe further into the fluid Execessive splashing in the sample - Fluid level is too low for the tube size Motor does not spin. Green light flashes. - Rotor is locked. Remove the obstruction 935C Cobb Place Blvd. Kennesaw, GA 30144 800.776.4431 • 770.421.0058 www.omni-inc.com PN: 03-225 Rev. C
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c137 79.159768, 2016/08/11-13:24:42 Create Date : 2017:10:05 15:56:14-04:00 Metadata Date : 2017:10:05 15:56:16-04:00 Modify Date : 2017:10:05 15:56:16-04:00 Creator Tool : Adobe InDesign CC 2017 (Windows) Instance ID : uuid:194b7a8b-1e92-48ca-9854-7e3eac484373 Original Document ID : xmp.did:6b2849db-2743-4f91-aca1-1ce5db3fbee8 Document ID : xmp.id:6eaf857b-e8e4-1443-9f4f-08b4f55fc9b3 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:a2b1bf71-5bdd-d149-910a-b0fca0ff75dc Derived From Document ID : xmp.did:a2b1bf71-5bdd-d149-910a-b0fca0ff75dc Derived From Original Document ID: xmp.did:6b2849db-2743-4f91-aca1-1ce5db3fbee8 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Windows) History Changed : / History When : 2017:10:05 15:56:14-04:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 8 Creator : Adobe InDesign CC 2017 (Windows)EXIF Metadata provided by EXIF.tools