TM_F7_01_06Aug2008 TM.F7.01
User Manual: TM.F7.01
Open the PDF directly: View PDF .
Page Count: 255
Download | |
Open PDF In Browser | View PDF |
F7 Drive User Manual Model: CIMR-F7U Document Number: TM.F7.01 Warnings and Cautions This Section provides warnings and cautions pertinent to this product, that if not heeded, may result in personal injury, fatality, or equipment damage. Yaskawa is not responsible for consequences of ignoring these instructions. WARNING YASKAWA manufactures component parts that can be used in a wide variety of industrial applications. The selection and application of YASKAWA products remain the responsibility of the equipment designer or end user. YASKAWA accepts no responsibility for the way its products are incorporated into the final system design. Under no circumstances should any YASKAWA product be incorporated into any product or design as the exclusive or sole safety control. Without exception, all controls should be designed to detect faults dynamically and fail safely under all circumstances. All products designed to incorporate a component part manufactured by YASKAWA must be supplied to the end user with appropriate warnings and instructions as to that part’s safe use and operation. Any warnings provided by YASKAWA must be promptly provided to the end user. YASKAWA offers an express warranty only as to the quality of its products in conforming to standards and specifications published in the YASKAWA manual. NO OTHER WARRANTY, EXPRESS OR IMPLIED, IS OFFERED. YASKAWA assumes no liability for any personal injury, property damage, losses, or claims arising from misapplication of its products. WARNING • Read and understand this manual before installing, operating, or servicing this Drive. All warnings, cautions, and instructions must be followed. All activity must be performed by qualified personnel. The Drive must be installed according to this manual and local codes. • Do not connect or disconnect wiring while the power is on. Do not remove covers or touch circuit boards while the power is on. Do not remove or insert the digital operator while power is on. • Before servicing, disconnect all power to the equipment. The internal capacitor remains charged even after the power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is below 50Vdc. To prevent electric shock, wait at least five minutes after all indicators are OFF and measure DC bus voltage level to confirm safe level. • Do not perform a withstand voltage test on any part of the unit. This equipment uses sensitive devices and may be damaged by high voltage. WARNING • The Drive is suitable for circuits capable of delivering not more than 100,000 RMS symmetrical Amperes, 240Vac maximum (200V Class) and 480Vac maximum (400V Class). Install adequate branch circuit short circuit protection per applicable codes. Failure to do so may result in equipment damage and/or personal injury. Refer to Appendix E for further details. • Do not connect unapproved LC or RC interference suppression filters, capacitors, or overvoltage protection devices to the output of the Drive. These devices may generate peak currents that exceed Drive specifications. i • To avoid unnecessary fault displays caused by contactors or output switches placed between Drive and motor, auxiliary contacts must be properly integrated into the control logic circuit. • YASKAWA is not responsible for any modification of the product made by the user; doing so will void the warranty. This product must not be modified. • Verify that the rated voltage of the Drive matches the voltage of the incoming power supply before applying power. • To meet CE directives, proper line filters and proper installation are required. • Some drawings in this manual may be shown with protective covers or shields removed, to describe details. These must be replaced before operation. • Observe electrostatic discharge procedures when handling circuit boards to prevent ESD damage. • The equipment may start unexpectedly upon application of power. Clear all personnel from the Drive, motor, and machine area before applying power. Secure covers, couplings, shaft keys, and machine loads before energizing the Drive. • Please do not connect or operate any equipment with visible damage or missing parts. The operating company is responsible for any injuries or equipment damage resulting from failure to heed the warnings in this manual. Intended Use Drives are intended for installation in electrical systems or machinery. The Drives are designed and manufactured in accordance with applicable UL and cUL standards, and CE directives. For use in the European Union, the installation in machinery and systems must conform to the following product standards of the Low Voltage Directive: EN 50178: 1997-10, Electronic Equipment for Use in Power Installations EN 60201-1: 1997-12 Machine Safety and Equipping with Electrical Devices Part 1: General Requirements (IEC 60204-1:1997) EN 61010: 1997-11 Safety Requirements for Information Technology Equipment (IEC 950:1991 + A1:1992 + A2:1993 + A3:1995 + A4:1996, modified) The F7 series Drives comply with the provisions of the Low Voltage Directive 73/23/EEC as amended by 93/68/EEC. These Drives conform to the following standard: EN 50178: 1997-10. Your supplier or Yaskawa representative must be contacted when using leakage current circuit breaker in conjunction with frequency inverters. In certain systems it may be necessary to use additional monitoring and safety devices in compliance with the relevant safety and accident prevention regulations. The frequency inverter hardware must not be modified. ii Introduction This section describes the applicability of the manual. This manual is applicable to F7 Drives defined by model numbers of CIMR-F7 U FFFF . This manual reflects the Software Version 3020. The F7 Drive is a Pulse Width Modulated Drive for AC 3-Phase induction motors. This type of Drive is also known as an Adjustable Frequency Drive, Variable Frequency Drive, AC Drive, AFD, ASD, VFD, VSD, and Inverter. In this manual, the F7 Drive will be referred to as the “Drive”. The LCD keypad/operator is equipped with local/remote functions, copy feature, 7 language choices, and 5 lines of display with 16 characters per line. User parameter settings can be recovered at any time via “user initialization” when enabled. Optional Drive Wizard software allows upload/download, as well as graphing and monitoring of Drive parameters from a PC for ease of Drive management. This manual may describe trademarked equipment, which is the property of other companies, who are the registered owners. Other Documents and Manuals are available to support special use or installation of this product. These documents may be provided with the product or upon request. Contact Yaskawa Electric America, Inc. as required. Documents may include the following: TM.F7.01…Manual included on CD ROM with product TM.F7.02…Programming Manual included on CD ROM with product DriveWizard...Software and Manual…Included on CD ROM with product Option Instructions… Included on CD ROM with product This manual is subject to change as product improvements occur. The latest version of the manual can be obtained from the Yaskawa website: www.yaskawa.com. The date shown on the rear cover is changed when revisions are made. The latest version of Drive software is also shown. The Drive’s capacity is categorized based on two types of load characteristics: Heavy Duty and Normal Duty. See Table i.1 below for the differences between Heavy Duty and Normal Duty. Table i.1 Drive Duty Selection Parameter C6-01 0: Heavy Duty (default) Rated Output Current Standard rating (varies by model*) 2: Normal Duty Extended rating (varies by model*) Overload Capacity Current Limit 150% for 1 min. 150% Approx. 110% for 1 min. (varies by model*) 120% Carrier Frequency Low (2kHz**) High (varies by model*) Maximum Output Frequency 300Hz 400Hz * See Drive Specifications ** Software version VSF103021 and higher allows the carrier frequency to be increased while in HD (C6-01=0). The continuous current and overload are automatically reduced to the levels indicated in Table 5.1. This manual references the various Drive capacities according to its model number CIMR-F7 U FFFF . See Drive Output Specifications Table i.2 and Table i.3 on the following pages for rated capacities and Drive specifications. iii Drive Output Specifications The standard Drive specifications are listed in the following tables. 208-240Vac Table i.2 208-240Vac Drive Specifications 208-240Vac Output ratings Normal Duty*1 Maximum output voltage 208-230Vac 2045 2055 2075 2090 2110*5 55.0 69.0 82.0 110.0 130.0 140.0 50 60 75 100 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 3.7 5.7 8.8 3 5 7.5 9.6 15.2 23.0 12.0 17.0 22.0 27.0 32.0 44.0 10 15 20 25 31.0 45.0 58.0 Heavy Duty*1 Model Number CIMR-F7U 20P4 20P7 21P5 Rated output 1.2 1.6 2.7 capacity (kVA) 0.5/0.75 1 2 Horsepower*2 Rated output 3.2 4.2 7.0 current (A) *3 Overload capacity (% of rated output current for 60 sec.) Current limit (% of rated output current) Carrier frequency*4 Maximum output frequency Rated output 1.4 1.8 3.0 capacity (kVA) 0.5/0.75 1 2 Horsepower*2 Rated output 3.6 4.6 7.8 current (A) *3 Overload capacity 107 107 108 (% of rated output current for 60 sec.) Current limit (% of rated output current) Carrier frequency 10 10 10 (kHz)*5 Maximum output frequency 71 30 40 85.0 115.0 145.0 180.0 215 283.0 125 150 346.0 360.0 150 138*3 150 138*3 2kHz 300.0Hz 4.1 6.4 8.8 3 5 7.5 12.0 18.0 23.0 29.0 34.0 44.0 10 15 20 25 30 40 62.0 73.0 82.0 120.0 50/60 75 75 100/125 10.8 16.8 23.0 31.0 46.2 59.4 74.8 88.0 115.0 162.0 192.0 215 107 120 120 107 117 117 114 312.0 140.0 160.0 150 150 360.0 415.0 116 120 107 113 120 109 115 120 10 10 5 5 8 2 2 2 120 8 10 15 15 8 10 10 400.0Hz 3-phase; 200, 208, 220, 230, or 240Vac (Proportional to input voltage) *1 The difference between Heavy Duty ratings and the Normal Duty ratings for the Drive are the rated input and output current, overload capacity, carrier frequency, current limit, and maximum output frequency. Parameter C6-01 must be set to value of “0” for Heavy Duty ratings and “2” for Normal Duty ratings. Factory default is Heavy Duty (C6-01=0). *2 Horsepower ratings are based on 230V or 460V NEC Table 430.150. The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor and Drive, be sure that the Drive's rated output current is appropriate for the motor's rated current. *3 Model 2110 has an overload rating of 138% of rated output current for 60 seconds and a current limit rating of 138%. Models 4220 and 4300 have an overload rating of 150% of rated output current for 45 seconds and a current limit rating of 150%. *4 When setting the carrier frequency above the factory default, the Drive must be derated. *5 Heavy Duty ratings for models 2110, 4220 and 4300 are effective in software version VSF103021 and higher. iv 480Vac Model Number CIMR-F7U Rated output capacity (kVA) Heavy Duty*1 Horsepower*2 Rated output current (A) Table i.3 480Vac Drive Specifications 41P5 42P2 43P7 44P0 45P5 40P4 40P7 1.4 1.6 2.8 4.0 5.8 6.6 0.5/0.75 1.8 1 2.1 1.5/2 3.7 3 5.3 5 7.6 8.7 Overload capacity*3 (% of rated output current for 60 sec.) Current limit (% of rated output current) Output ratings Horsepower*2 Normal Duty *1 Rated output current (A) Overload capacity*3 (% of rated output current for 60 sec.) Current limit (% of rated output current) Carrier frequency (kHz)*5 Maximum output frequency Maximum output voltage Model Number CIMR-F7U Rated output capacity (kVA) Horsepower *2 Heavy Duty*1 Rated output current (A) Output ratings Normal 4015 4018 4022 9.5 13.0 18.0 24.0 30.0 34.0 7.5 12.5 10 17.0 15 24.0 20 31.0 25 39.0 30 45.0 38.0 150 2kHz 300.0Hz 1.4 1.6 2.8 4.0 5.8 6.6 9.5 13.0 21.0 26.0 30.0 0.5/0.75 1 1.5/2 3 5 - 7.5 10 15/20 25 30 30 1.8 2.1 3.7 5.3 7.6 8.7 12.5 17.0 27.0 34.0 40.0 50.4 120 120 120 120 120 120 120 120 107 109 117 107 15 15 8 10 10 10 120 15 15 15 15 15 15 400.0Hz 3-phase; 380, 400, 415, 440, 460, or 480Vac (Proportional to input voltage) 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 46.0 57.0 69.0 85.0 110.0 140.0 160.0 200.0 230.0 280.0 315.0 450.0 40 50 60 75 100 125/150 - 200 250 300 350 500 60.0 75.0 91.0 112.0 150.0 180.0 216.0 260.0 304.0 370.0 414.0 590.0 150 150*3 150*3 150 150*3 150*3 510.0 Overload capacity*3 (% of rated output current for 60 sec.) Current limit (% of rated output current) Carrier frequency*4 Maximum output frequency Duty*1 4011 150 Carrier frequency*4 Maximum output frequency Rated output capacity (kVA) 47P5 2kHz 300.0Hz Rated output capacity (kVA) 51.0 59.0 73.0 95.0 120.0 140.0 180.0 200.0 230.0 315.0 390.0 Horsepower*2 40/50 60 75 100 125 150 200 - 250 300/350 400/450 500+ Rated output current (A) 67.2 77.0 96.0 125.0 156.0 180.0 240.0 260.0 304.0 414.0 515.0 675.0 107 117 114 108 115 120 108 120 120 107 118 120 5 5 2 2 2 Overload capacity*3 (% of rated output current for 60 sec.) Current limit (% of rated output current) Carrier frequency (kHz)*5 Maximum output frequency Maximum output voltage 120 8 8 8 5 5 8 5 400.0Hz 3-phase, 380, 400, 415, 440, 460 or 480Vac (Proportional to input voltage) *1 The difference between Heavy Duty ratings and the Normal Duty ratings for the Drive are the rated input and output current, overload capacity, carrier frequency, current limit, and maximum output frequency. Parameter C6-01 must be set to value of “0” for Heavy Duty ratings and “2” for Normal Duty ratings. Factory default is Heavy Duty (C6-01=0). *2 Horsepower ratings are based on 230V or 460V NEC Table 430.150. The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor and Drive, be sure that the Drive's rated output current is appropriate for the motor's rated current. *3 Model 2110 has an overload rating of 138% of rated output current for 60 seconds and a current limit rating of 138%. Models 4220 and 4300 have an overload rating of 150% of rated output current for 45 seconds and a current limit rating of 150%. *4 When setting the carrier frequency above the factory default, the Drive must be derated. *5 Heavy Duty ratings for models 2110, 4220 and 4300 are effective in software version VSF103021 and higher. v Notes: vi Table of Contents Warnings and Cautions..................................................................................... i Introduction ..................................................................................................... iii Table of Contents........................................................................................... vii Chapter 1 - Physical Installation ...............................................................................1-1 F7 Model Number, Enclosure, Heat Loss, and Weight.................................1-2 Confirmations upon Delivery.........................................................................1-3 Component Names .......................................................................................1-5 Exterior and Mounting Dimensions ...............................................................1-7 Checking and Controlling the Installation Site ............................................1-11 Installation Orientation and Clearances ......................................................1-12 Removing and Attaching the Terminal Cover .............................................1-13 Removing/Attaching the Digital Operator and Front Cover.........................1-14 Chapter 2 - Electrical Installation..............................................................................2-1 Terminal Block Configuration........................................................................2-2 Wiring Main Circuit Terminals .......................................................................2-3 Control Wiring .............................................................................................2-20 Electromagnetic Compatibility (EMC) .........................................................2-26 Installing and Wiring Option Boards............................................................2-30 Chapter 3 - Digital Operator ......................................................................................3-1 Digital Operator Display ................................................................................3-2 Digital Operator Keys....................................................................................3-3 Drive Mode Indicators ...................................................................................3-4 Drive Main Menus .........................................................................................3-6 Quick Setting Menu (-QUICK-) ...................................................................3-11 Programming Menu (-ADV-) .......................................................................3-12 Example of Changing a Parameter.............................................................3-15 Table of Contents vii Chapter 4 - Start-Up ................................................................................................... 4-1 Drive Start-Up Preparation ........................................................................... 4-2 Drive Start-Up Procedures ........................................................................... 4-5 Chapter 5 - Basic Programming ............................................................................... 5-1 Description of Parameter Tables .................................................................. 5-2 Control Method ............................................................................................. 5-2 Speed Command Source ............................................................................. 5-3 Run Command Source ................................................................................. 5-4 Stopping Method .......................................................................................... 5-5 Accel/Decel Time.......................................................................................... 5-8 Carrier Frequency......................................................................................... 5-9 Preset Reference........................................................................................ 5-11 Input Voltage Setting .................................................................................. 5-12 V/F Pattern ................................................................................................. 5-12 Motor Setup ................................................................................................ 5-20 PG Option................................................................................................... 5-20 Analog Output Gain .................................................................................... 5-21 Motor Overload Fault .................................................................................. 5-22 Stall Prevention .......................................................................................... 5-23 Chapter 6 - Diagnostics & Troubleshooting ............................................................ 6-1 Fault Detection ............................................................................................. 6-2 Alarm Detection .......................................................................................... 6-10 Operator Programming Errors (OPE) ......................................................... 6-15 Auto-Tuning Faults ..................................................................................... 6-17 Digital Operator COPY Function Faults...................................................... 6-19 Troubleshooting.......................................................................................... 6-20 Main Circuit Test Procedure ....................................................................... 6-28 Drive Date Stamp Information ................................................................... 6-31 Table of Contents viii Chapter 7 - Maintenance............................................................................................7-1 Periodic Inspection........................................................................................7-2 Preventive Maintenance ...............................................................................7-3 Periodic Maintenance of Parts ......................................................................7-4 Heatsink Cooling Fan Replacement .............................................................7-5 Removing and Mounting the Terminal Card .................................................7-7 Appendix A - Parameters.......................................................................................... A-1 F7 Parameter List ........................................................................................ A-3 F7 Monitor List ........................................................................................... A-38 F7 Fault Trace List ..................................................................................... A-41 F7 Fault History List ................................................................................... A-41 Appendix B - Capacity Related Parameters............................................................ B-1 Drive Capacity Selection.............................................................................. B-2 Parameters Affected by Drive Capacity Setting........................................... B-3 Appendix C - Specifications..................................................................................... C-1 Standard Drive Specifications...................................................................... C-2 Appendix D - Communications ................................................................................ D-1 Using Modbus Communication .................................................................... D-2 Modbus Function Code Details.................................................................... D-8 Modbus Data Tables.................................................................................. D-10 Modbus Self-Diagnosis .............................................................................. D-18 Table of Contents ix Appendix E - Peripheral Devices ..............................................................................E-1 Branch Circuit Short Circuit Protection .........................................................E-2 Branch Circuit Overload Protection ............................................................. E-5 Peripheral Devices .......................................................................................E-6 Appendix F - Spare Parts .......................................................................................... F-1 F7 Primary Spare Parts - 208/230/240Vac...................................................F-2 F7 Primary Spare Parts - 480Vac.................................................................F-3 Index...................................................................................................... Index-1 Support Services .................................................................... Inside rear cover Table of Contents x Chapter 1 Physical Installation This chapter describes the requirements for receiving and installing the F7 Drive. F7 Model Number, Enclosure, Heat Loss, and Weight ..... 1-2 Confirmations upon Delivery ............................................. 1-3 Component Names ........................................................... 1-5 Exterior and Mounting Dimensions ................................... 1-7 Checking and Controlling the Installation Site................. 1-11 Installation Orientation and Clearances .......................... 1-12 Removing and Attaching the Terminal Cover.................. 1-13 Removing/Attaching the Digital Operator and Front Cover .............................................................. 1-14 Physical Installation 1 - 1 F7 Model Number, Enclosure, Heat Loss, and Weight Table 1.1 F7 Model Number and Enclosure Style Input Voltage 3-Phase 208-240Vac 208-230Vac 480 Vac F7 Model-Number CIMR-F7U20P4 CIMR-F7U20P7 CIMR-F7U21P5 CIMR-F7U22P2 CIMR-F7U23P7 CIMR-F7U25P5 CIMR-F7U27P5 CIMR-F7U2011 CIMR-F7U2015 CIMR-F7U2018 CIMR-F7U2022 CIMR-F7U2030 CIMR-F7U2037 CIMR-F7U2045 CIMR-F7U2055 CIMR-F7U2075 CIMR-F7U2090 CIMR-F7U2110 CIMR-F7U40P4 CIMR-F7U40P7 CIMR-F7U41P5 CIMR-F7U42P2 CIMR-F7U43P7 CIMR-F7U44P0 CIMR-F7U45P5 CIMR-F7U47P5 CIMR-F7U4011 CIMR-F7U4015 CIMR-F7U4018 CIMR-F7U4022 CIMR-F7U4030 CIMR-F7U4037 CIMR-F7U4045 CIMR-F7U4055 CIMR-F7U4075 CIMR-F7U4090 CIMR-F7U4110 CIMR-F7U4132 CIMR-F7U4160 CIMR-F7U4185 CIMR-F7U4220 CIMR-F7U4300 Enclosure Style NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) Open Chassis (IP00) Open Chassis (IP00) Open Chassis (IP00) Open Chassis (IP00) Open Chassis (IP00) Open Chassis (IP00) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) NEMA Type 1 (IP20) Open Chassis (IP00) Open Chassis (IP00) Open Chassis (IP00) Open Chassis (IP00) Open Chassis (IP00) Open Chassis (IP00) Open Chassis (IP00) Open Chassis (IP00) Weight lb (kg) 6.6 (3.0) 8.8 (4.0) 13.2 (6.0) 15.4 (7.0) 24.2 (11.0) 53 (24) 59 (27) 125 (57) 139 (63) 189 (86) 191 (87) 238 (108) 330 (150) 6.6 (3.0) 8.8 (4.0) 13.2 (6.0) 22 (10) 53 (24) 88 (40) 194 (88) 196 (89) 224 (102) 265 (120) 352 (160) 572 (259) 616 (279) 891 (404) Physical Installation 1 - 2 Heat Loss (watts) Heatsink Internal Total 19 26 48 68 110 164 219 357 416 472 583 883 1010 1228 1588 1956 2194 2733 14 17 36 59 80 90 127 193 232 296 389 420 691 801 901 1204 1285 1614 1889 2388 2791 2636 3797 5838 39 42 50 59 74 84 113 168 182 208 252 333 421 499 619 844 964 1234 39 41 48 56 68 70 81 114 158 169 201 233 298 332 386 478 562 673 847 1005 1144 1328 1712 2482 58 68 98 127 184 248 332 525 598 680 835 1216 1431 1727 2207 2800 3158 3967 53 58 84 115 148 160 208 307 390 465 590 653 989 1133 1287 1682 1847 2287 2736 3393 3935 3964 5509 8320 Confirmations upon Delivery Receiving Checks Check the following items as soon as the Drive is received. Table 1.2 Receiving Checks Item Method Has the correct model of Drive been delivered? Check the model number on the nameplate on the right side of the Drive. Reconcile with packing slip and/or order information. Is the Drive damaged in any way? Inspect the entire exterior of the Drive to see if there are any dents, scratches or other damage resulting from shipping. Are any screws or other components loose? Use a screwdriver or other tool to check for tightness. If there are any irregularities in the above items, contact the shipping company, or the distributor / representative who sold the Drive, or a Yaskawa office immediately. Nameplate Information A nameplate is attached to the right side of each Drive. The following nameplate is an example for a standard Drive. Drive Spec Number Drive Model Number Input Power Rating Output Power Rating Weight Software Number Serial Number UL File Number Note: The Drive Model Number, Drive Spec Number, Software Number, and Serial Number are required to completely identify a Drive. HD - Heavy Duty; ND - Normal Duty Fig 1.1 F7 Drive Nameplate Physical Installation 1 - 3 Drive Model Numbers The model number on the nameplate indicates the design specification, voltage, and rating of the Drive in alphanumeric codes. CIMR – F7 U 2 0 2 2 AC Drive F7 Family No. 2 4 Rating Spec UL Specification No. U Voltage 3-phase, 208-240Vac 3-phase, 480Vac Fig 1.2 Drive Model Number Structure Drive Enclosure and Revision Code The SPEC number on the nameplate indicates the voltage, Drive rating, enclosure type, and the revision code of the Drive in alphanumeric codes. The SPEC number for Drives that have custom features, i.e. CASE software, will have a SPEC number that indicates the custom features installed. 20221E No. Voltage 2 4 3-phase, 208 - 240Vac Hardware Revision 3-phase, 480Vac Rating Enclosure Type No. 0 Open chassis (IEC IP00) 1 NEMA Type 1 (IEC IP20) Fig 1.3 SPEC Number Structure Open Chassis Type (IEC IP00) Protected so that parts of the human body cannot reach electrically charged parts from the front when the Drive is mounted in a control panel, also called protected chassis. TERMS NEMA Type 1 (IEC IP20) The Drive is shielded from the exterior, and can thus be mounted to the interior wall of a building (not necessarily enclosed in a control panel). The protective structure conforms to the standards of NEMA 1 in the USA. All protective covers (Fig 1.4 and Fig 1.6) must be installed to conform with IEC IP20 and NEMA Type 1 requirements. Physical Installation 1 - 4 Component Names Models CIMR-F7U20P4 thru 2018 and 40P4 thru 4018 The external appearance, component names, and terminal arrangement of the Drive are shown in Fig 1.4 and 1.5. Top protective cover [Required for NEMA Type 1 (IEC IP20)] Mounting hole Front cover Digital Operator Die-cast Heat Sink Terminal cover Nameplate Bottom protective cover Fig 1.4 Drive Appearance { Control circuit terminal layout label Control circuit terminals See Fig. 2.3 for actual terminal layout Main circuit terminals Charge indicator Ground terminal Ground terminal Fig 1.5 Terminal Arrangement (Terminal Cover Removed) Physical Installation 1 - 5 Models CIMR-F7U2022 thru 2110 and 4030 thru 4300 The external appearance, component names, and terminal arrangement of the Drive are shown in Fig 1.6 and 1.7. Mounting holes Mounting holes Drive cover Drive cover Cooling fan Cooling fan Front Frontcover cover Digital Operator Operator Digital Nameplate Nameplate Terminal cover Terminal cover Fig 1.6 Drive Appearance { Control circuit terminal layout label Control circuit terminals Charge indicator See Fig. 2.3 for actual terminal layout Main circuit terminals Ground terminal Ground terminal Fig 1.7 Terminal Arrangement (Terminal Cover Removed) Physical Installation 1 - 6 Exterior and Mounting Dimensions DIMENSIONS: F7 (NEMA 1) 208-240V (F7U20P4-2018) 480V (F7U40P4-4018) Physical Installation 1 - 7 Physical Installation 1 - 8 Physical Installation 1 - 9 Physical Installation 1 - 10 Checking and Controlling the Installation Site Install the Drive as described below and maintain optimum conditions. Installation Site Install the Drive to a non-combustible surface under the following conditions in UL Pollution Degree 2 environments. This excludes wet locations where pollution may become conductive due to moisture, and locations containing conductive foreign matter. Table 1.3 Installation Site Specifications Type Ambient Operating Temperature Humidity Plenum Rated NEMA Type 1 14°F-to 104°F (-10-to +40°C) 95%-RH-or-less-(no-condensation) Yes Open Chassis 14°F-to 113°F (-10-to-+45°C) 95%-RH-or-less-(no-condensation) No Protective covers are attached to the top and bottom of the Drive. It is recommended to remove the protective covers before operating a NEMA Type 1 Drive (Models CIMR-F7U2030/4055 and smaller) in a panel to obtain the 113° (45°C) ambient operating temperature. Observe the following precautions when installing the Drive. Make sure to install: • in a clean location which is free from oil mist and dust. • in an environment where metal shavings, oil, water, or other foreign materials do not get into the Drive. • in a location free from radioactive materials and combustible materials (e.g. wood). • in a location free from harmful gases and liquids. • in a location free from excessive vibration. • in a location free from chlorides. • in a location away from direct sunlight. Controlling the Ambient Temperature To enhance the reliability of operation, the Drive should be installed in an environment free from extreme temperature variation. If the Drive is installed in an enclosure, use a cooling fan or air conditioner to maintain the internal air temperature below 113°F (45°C). Protecting the Drive from Foreign Matter During Drive installation and project construction, it is possible to have foreign matter such as metal shavings or wire clippings fall inside the Drive. To prevent foreign matter from falling into the Drive, place a temporary cover over the Drive. Always remove the temporary cover from the Drive before start-up. Otherwise, ventilation will be reduced, causing the Drive to overheat. Physical Installation 1 - 11 Installation Orientation and Clearances Install the Drive vertically so as not to reduce the cooling efficiency. When installing the Drive, always provide the following installation clearances to allow normal heat dissipation and air flow. Ensure that the heatsink is against a closed surface to avoid diverting cooling air around the heatsink. 1.97in *1 (50mm) minimum 4.75in *2 (120mm) minimum Air 1.2in (30.5mm) minimum 1.2in (30.5mm) minimum 1.97in (50mm) minimum 4.75in (120mm) minimum Air Horizontal Clearance Vertical Clearance *1 For Drive models F7U2110, F7U4160, and F7U4220, this clearance dimension is 4.75in (120mm) minimum. For Drive model F7U4300, this clearance dimension is 11.8in (300mm) minimum. All other models require 1.97in (50mm) minimum. *2 For Drive model F7U4300, this clearance dimension is 11.8in (300mm) minimum. All other models require 4.75in (120mm) minimum. Fig 1.8 Drive Installation Orientation and Clearance IMPORTANT 1. The same clearance is required horizontally and vertically for both Open Chassis (IP00) and NEMA Type 1 Drives. 2. Always remove the top and bottom protection covers before installing a CIMR-F7U2018/ 4018 and smaller Drive in a panel. 3. Always provide enough clearance for lifting eye bolts and the main circuit wiring when installing a CIMR-F7U2022/4030 and larger Drive in a panel. Physical Installation 1 - 12 Removing and Attaching the Terminal Cover Remove the terminal cover to connect cables to the control circuit and main circuit terminals. Removing the Terminal Cover Models CIMR-F7U20P4 thru 2018 and 40P4 thru 4018 Loosen the screw at the bottom of the terminal cover, press in on the sides of the terminal cover in the directions of arrows 1, and then lift up on the terminal in the direction of arrow 2. 1 2 1 Fig 1.9 Removing the Terminal Cover Models CIMR-F7U2022 thru 2110 and 4030 thru 4300 Loosen the screws on the left and right at the top of the terminal cover, pull down the terminal cover in the direction of arrow 1, and then lift up on the terminal cover in the direction of arrow 2. 1 2 Fig 1.10 Removing the Terminal Cover Attaching the Terminal Cover After wiring the terminal block, attach the terminal cover by reversing the removal procedure. For Models CIMR-F7U2018/4018 and smaller, insert the tab on the top of the terminal cover into the groove on the Drive, and press in on the bottom of the terminal cover until it clicks into place. For Drives CIMR-F7U2022/4030 and larger, insert the tab on the top of the terminal cover into the groove on the Drive, and secure the terminal cover by lifting it up toward the top of the Drive. Physical Installation 1 - 13 Removing/Attaching the Digital Operator and Front Cover Models CIMR-F7U20P4 thru 2018 and 40P4 thru 4018 For Models CIMR-F7U2018/4018 and smaller, remove the terminal cover and then use the following procedures to remove the Digital Operator and front cover. Removing the Digital Operator Press on the side of the Digital Operator in the direction of arrow 1 to unlock, then lift the Digital Operator in the direction of arrow 2 to remove it as shown in Fig 1.11. 2 1 Fig 1.11 Removing the Digital Operator Removing the Front Cover Press the left and right sides of the front cover in the direction of arrows 1 and lift the bottom of cover in the direction of arrow 2 to remove it as shown in Fig 1.12. 1 2 1 Fig 1.12 Removing the Front Cover Mounting the Front Cover Mount the front cover to the Drive by performing the steps to remove the front cover in reverse order. 1. Do not mount the front cover with the Digital Operator attached as this may cause the Digital Operator to malfunction due to improper mating with its connector. 2. Insert the tab of the upper part of the front cover into the groove of the Drive and press the lower part of the front cover onto the Drive until it snaps into place. Physical Installation 1 - 14 Mounting the Digital Operator After attaching the front cover, mount the Digital Operator onto the Drive using the following procedure: 1. Hook the Digital Operator at A (two locations) on the left side of the opening on the front cover by moving in the direction of arrow 1 as shown in the following illustration. 2. Press the Digital Operator in the direction of arrow 2 until it snaps in place at B (two locations). A 1 B 2 Fig 1.13 Mounting the Digital Operator IMPORTANT 1. Do not remove or attach the Digital Operator and do not mount or remove the front cover using methods other than those described above, or damage to the Digital Operator or Drive may occur. 2. Never attach the front cover to the Drive with the Digital Operator already attached. Damage to the Digital Operator may occur. Always attach the front cover to the Drive first, and then attach the Digital Operator to the front cover. Physical Installation 1 - 15 Models CIMR-F7U2022 thru 2110 and 4030 thru 4300 For Models CIMR-F7U2022/4030 and larger, remove the terminal cover and then use the following procedures to remove the Digital Operator and front cover. Removing the Digital Operator Use the same procedure for Models CIMR-F7U20P4 thru 2018 and 40P4 thru 4018. Removing the Front Cover Loosen all screws on the front cover. Lift up at the location labelled 1 at the top of the control circuit terminal card and move in the direction of arrow 2. 2 1 Fig 1.14 Removing the Front Cover Mounting the Front Cover Attach the front cover by reversing the procedure to remove it. 1. Confirm that the Digital Operator is not mounted on the front cover. If the cover is attached while the Digital Operator is mounted to it, the Digital Operator may malfunction due to improper mating with its connector. 2. Insert the tab on the top of the front cover into the slot on the Drive and press in on the cover until it clicks into place on the Drive. Mounting the Digital Operator Use the same procedure for Models CIMR-F7U20P4 thru 2018 and 40P4 thru 4018. Physical Installation 1 - 16 Chapter 2 Electrical Installation This chapter describes wiring terminals, main circuit terminal connections, main circuit terminal wiring specifications, control circuit terminals, and control circuit wiring specifications. Terminal Block Configuration ............................................ 2-2 Wiring Main Circuit Terminals ........................................... 2-3 Control Wiring ................................................................. 2-20 Electromagnetic Compatibility (EMC) ............................. 2-26 Installing and Wiring Option Boards................................ 2-30 Electrical Installation 2 - 1 Terminal Block Configuration The wiring terminals are shown in Fig 2.1, Fig 2.2 and Fig 2.3. Control circuit terminal layout label Control circuit terminals Ground terminal See Fig. 2.3 below for actual terminal layout Main circuit terminals Charge indicator Ground terminal Ground terminal Fig 2.1 Terminal Configuration for Models CIMR-F7U2018/4018 and Smaller Control circuit terminal layout label Control circuit terminals Charge indicator See Fig. 2.3 below for actual terminal layout Main circuit terminals Ground terminal Ground terminal Fig 2.2 Terminal Configuration for Models CIMR-F7U2022/4022 and Larger SN E(G) SC S1 SP S2 A1 S3 A2 S4 +V S5 AC S6 S7 -V A3 S8 MP AC RP FM AC AM IG R+ R- S+ M5 M6 MA MB MC S- Fig 2.3 Control Circuit Terminal Layout Electrical Installation 2 - 2 M3 M4 M1 M2 E(G) Wiring Main Circuit Terminals Applicable Wire Sizes and Closed-loop Connectors Select the appropriate wires and crimp terminals from Table 2.1 and Table 2.2. Refer to instruction manual TOE-C726-2 for Braking Resistor Unit and Braking Unit wire sizes. Table 2.1 208-240Vac Wire Sizes and Connector Specifications Drive Model CIMR-F7U Terminal Symbol R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 2, B1, B2 20P4 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 2, B1, B2 20P7 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 2, B1, B2 21P5 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 2, B1, B2 22P2 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 2, B1, B2 23P7 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 2, B1, B2 25P5 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 2, B1, B2 27P5 R/L1, S/L2, T/L3, 2, B1, B2 2011 , 1, U/T1, V/T2, W/T3 R/L1, S/L2, T/L3, , 1, Terminal Screws Clamping Torque lb. in. (N•m) Possible Wire Sizes AWG (mm2) *1 Recommended Wire Size AWG (mm2) *2 M4 10.6 to 13.2 (1.2 to 1.5) 14 to 10 (2 to 5.5) 14 (2) M4 10.6 to 13.2 (1.2 to 1.5) 14 to 10 (2 to 5.5) 14 (2) M4 10.6 to 13.2 (1.2 to 1.5) 14 to 10 (2 to 5.5) 14 (2) M4 10.6 to 13.2 (1.2 to 1.5) 14 to 10 (2 to 5.5) 14 (2) M4 10.6 to 13.2 (1.2 to 1.5) 12 to 10 (3.5 to 5.5) 12 (3.5) M4 10.6 to 13.2 (1.2 to 1.5) 12 to 10 (3.5 to 5.5) 10 (5.5) M5 21.99 (2.5) 8 to 6 (8 to 14) 8 (8) M5 21.99 (2.5) 6 to 4 (14 to 22) M6 35.2 to 43.99 (4.0 to 5.0) 4 to 2 (22 to 38) 21.99 (2.5) 35.2 to 43.99 (4.0 to 5.0) 8 to 6 (8 to 14) 4 (22) 79.2 to 87.97 (9.0 to 10.0) 3 to 2 (30 to 38) 21.99 (2.5) 35.2 to 43.99 (4.0 to 5.0) 8 to 6 (8 to 14) 4 (22) 79.2 to 87.97 (9.0 to 10.0) N/A 2 U/T1, V/T2, W/T3 2015 B1, B2 M5 M6 R/L1, S/L2, T/L3, , 1, 2 M8 U/T1, V/T2, W/T3 2018 B1, B2 M5 M6 R/L1, S/L2, T/L3, , 1, R1/L11, S1/L21, T1/L31 M8 U/T1, V/T2, W/T3, 2022 3 M6 M8 R/L1, S/L2, T/L3, , 1 U/T1, V/T2, W/T3, R1/L11, S1/L21, T1/L31 2030 3 M8 M6 M8 35.2 to 43.99 (4.0 to 5.0) 79.2 to 87.97 (9.0 to 10.0) 79.2 to 87.97 (9.0 to 10.0) 35.2 to 43.99 (4.0 to 5.0) 79.2 to 87.97 (9.0 to 10.0) Electrical Installation 2 - 3 N/A N/A N/A N/A N/A 4 (22) 6 (14) 3 (30) 4 (22) Application Dependent 4 (22) 2 (38) 3 (30) Application Dependent 4 (22) 1 (50) 2 (38) Application Dependent 4 (22) 1/0 (60) Application Dependent 4 (22) Wire Type 600Vac UL Approved vinyl-sheathed or equivalent Table 2.1 208-240Vac Wire Sizes and Connector Specifications (Continued) Terminal Symbol Terminal Screws Clamping Torque lb. in. (N•m) Possible Wire Sizes AWG (mm2) *1 Recommended Wire Size AWG (mm2) *2 R/L1, S/L2, T/L3, , 1 U/T1, V/T2, W/T3, R1/L11, S1/L21, T1/L31 M10 154.8 to 197.9 (17.6 to 22.5) N/A 4/0 (100) Drive Model CIMR-F7U M8 3 2037 M10 r/l1, s/l2 R/L1, S/L2, T/L3, , M4 1, R1/L11, S1/L21, T1/L31 M10 U/T1, V/T2, W/T3 2045 M8 3 M10 r/l1, s/l2 M4 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3, R1/L11, S1/L21, T1/L31 M8 3 2055 M10 M10 r/l1, s/l2 M4 R/L1, S/L2, T/L3, R1/L11, S1/L21, T1/L31 M10 U/T1, V/T2, W/T3 , M12 1 2075 M8 3 M12 r/l1, s/l2 R/L1, S/L2, T/L3, , M4 1, R1/L11, S1/L21, T1/L31 M12 U/T1, V/T2, W/T3 2090 M8 3 M12 r/l1, s/l2 R/L1, S/L2, T/L3, , M4 1, R1/L11, S1/L21, T1/L31 M12 U/T1, V/T2, W/T3 2110 3 M8 M12 r/l1, s/l2 M4 77.4 to 95.0 (8.8 to 10.8) 154.8 to 197.9 (17.6 to 22.5) 11.4 to 12.3 (1.3 to 1.4) 154.8 to 197.9 (17.6 to 22.5) 77.4 to 95.0 (8.8 to 10.8) 154.8 to 197.9 (17.6 to 22.5) 11.4 to 12.3 (1.3 to 1.4) 154.8 to 197.9 (17.6 to 22.5) 77.4 to 95.0 (8.8 to 10.8) 154.8 to 197.9 (17.6 to 22.5) 11.4 to 12.3 (1.3 to 1.4) 154.8 to 197.9 (17.6 to 22.5) 276.2 to 344.8 (31.4 to 39.2) 77.4 to 95.0 (8.8 to 10.8) 276.2 to 344.8 (31.4 to 39.2) 11.4 to 12.3 (1.3 to 1.4) 276.2 to 344.8 (31.4 to 39.2) 77.4 to 95.0 (8.8 to 10.8) 276.2 to 344.8 (31.4 to 39.2) 11.4 to 12.3 (1.3 to 1.4) 276.2 to 344.8 (31.4 to 39.2) 77.4 to 95.0 (8.8 to 10.8) 276.2 to 344.8 (31.4 to 39.2) 11.4 to 12.3 (1.3 to 1.4) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Wire Type Application Dependent 2 (38) 16 (1.25) 300 (150) 250 (125) Application Dependent 1 (50) 16 (1.25) 1/0 X 2P (60 X 2P) Application Dependent 1/0 (60) 16 (1.25) 4/0 X 2P (100 X 2P) 3/0 X 2P (80 X 2P) 3/0 X 2P (80 X 2P) Application Dependent 3/0 (80) 16 (1.25) 250 X 2P (125 X 2P) 4/0 X 2P (100 X 2P) Application Dependent 2/0 X 2P (70 X 2P) 16 (1.25) 350 X 2P (200 X 2P) 300 X 2P (150 X 2P) Application Dependent 300 X 2P (150 X 2P) 16 (1.25) 600Vac UL Approved vinyl-sheathed or equivalent *1 Wire size range provided for Drives using insulated screw-type terminal blocks. All other models require the use of UL listed connectors. Refer to Table 2.3. *2 Recommended wire sizes are based on the normal duty (ND) current ratings and NEC Article 310 Table 310.16, 75 degree Celsius copper or equivalent. When sizing wiring based on the heavy duty (HD) current ratings, consult NEC Article 430 and any other applicable codes. Electrical Installation 2 - 4 Table 2.2 480Vac Wire Sizes and Connector Specifications Drive Model CIMR-F7U Terminal Symbol R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 2, B1, B2 40P4 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 2, B1, B2 40P7 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 2, B1, B2 41P5 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 2, B1, B2 42P2 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 2, B1, B2 43P7 44P0 45P5 47P5 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 4011 , Clamping Torque lb. in. (N•m) Possible Wire Sizes AWG (mm2) * 1 Recommended Wire Size AWG (mm2) *2 M4 10.6 to 13.2 (1.2 to 1.5) 14 to 10 (2 to 5.5) 14 (2) M4 10.6 to 13.2 (1.2 to 1.5) 14 to 10 (2 to 5.5) 14 (2) M4 10.6 to 13.2 (1.2 to 1.5) 14 to 10 (2 to 5.5) 14 (2) M4 10.6 to 13.2 (1.2 to 1.5) 14 to 10 (2 to 5.5) 14 (2) M4 10.6 to 13.2 (1.2 to 1.5) 14 to 10 (2 to 5.5) 2, B1, B2 M4 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 R/L1, S/L2, T/L3, Terminal Screws 2, B1, B2 M4 1, R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3 2,B1, B2 10 (5.5) 10 (5.5) 12 to 10 (3.5 to 5.5) 12 (3.5) 8 (8) 21.99 (2.5) 8 to 6 (8 to 14) 8 (8) 21.99 (2.5) 35.2 to 43.99 (4.0 to 5.0) 10 to 6 (5.5 to 14) 10 (5.5) 35.2 to 43.99 (4.0 to 5.0) 8 to 2 (8 to 38) 21.99 (2.5) 35.2 to 43.99 (4.0 to 5.0) 8 (8) 8 to 4 (8 to 22) 2 U/T1, V/T2, W/T3 B1, B2 M5 M6 4022 14 (2) M5 4018 , 1, T1/L31 14 to 10 (2 to 5.5) 10 to 6 (5.5 to 14) M6 R/L1, S/L2, T/L3, 12 (3.5) 21.99 (2.5) M6 1, 14 (2) M5 M5 4015 , 15.6 (1.8) 12 (3.5) 12 to 10 (3.5 to 5.5) 2, B1, B2 U/T1, V/T2, W/T3 R/L1, S/L2, T/L3, 10.6 to 13.2 (1.2 to 1.5) 3, R1/L11, S1/L21, M6 35.2 to 43.99 (4.0 to 5.0) N/A 79.2 to 87.97 (9.0 to 10.0) N/A U/T1, V/T2, W/T3 M8 Electrical Installation 2 - 5 Wire Type 10 (5.5) 6 (14) 8 (8) 8 (8) 8 (8) 4 (22) 6 (14) 6 (14) 600Vac UL Approved vinyl-sheathed or equivalent Table 2.2 480Vac Wire Sizes and Connector Specifications (Continued) Drive Model CIMR-F7U Terminal Symbol R/L1, S/L2, T/L3, 4030 , 1, T1/L31 Terminal Screws Clamping Torque lb. in. (N•m) Possible Wire Sizes AWG (mm2) * 1 M6 35.2 to 43.99 (4.0 to 5.0) N/A M8 79.2 to 87.97 (9.0 to 10.0) N/A M8 79.2 to 87.97 (9.0 to 10.0) N/A 3, R1/L11, S1/L21, U/T1, V/T2, W/T3 R/L1, S/L2, T/L3, , 1, R1/L11, S1/L21, T1/L31 U/T1, V/T2, W/T3 4037 M6 3 M8 R/L1, S/L2, T/L3, , 1, R1/L11, S1/L21, T1/L31 M8 U/T1, V/T2, W/T3 4045 M6 3 M8 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3, R1/L11, S1/L21, T1/L31 4055 M8 M6 3 M8 R/L1, S/L2, T/L3, , 1, R1/L11, S1/L21, T1/L31 M10 U/T1, V/T2, W/T3 4075 M8 3 M10 r/l1, s200/l2200, s400/l2400 R/L1, S/L2, T/L3, , M4 1, R1/L11, S1/L21, T1/L31 M10 U/T1, V/T2, W/T3 4090 M8 3 M10 r/l1, s200/l2200, s400/l2400 R/L1, S/L2, T/L3, , M4 1, R1/L11, S1/L21, T1/L33 M10 U/T1, V/T2, W/T3 4110 3 M8 M12 r/l1, s200/l2200, s400/l2400 M4 35.2 to 43.99 (4.0 to 5.0) 79.2 to 87.97 (9.0 to 10.0) 79.2 to 87.97 (9.0 to 10.0) 35.2 to 43.99 (4.0 to 5.0) 79.2 to 87.97 (9.0 to 10.0) 79.2 to 87.97 (9.0 to 10.0) 35.2 to 43.99 (4.0 to 5.0) 79.2 to 87.97 (9.0 to 10.0) 154.8 to 197.5 (17.6 to 22.5) 77.4 to 95.0 (8.8 to 10.8) 154.8 to 197.5 (17.6 to 22.5) 11.4 to 12.3 (1.3 to 1.4) 154.8 to 197.5 (17.6 to 22.5) 77.4 to 95.0 (8.8 to 10.8) 154.8 to 197.5 (17.6 to 22.5) 11.4 to 12.3 (1.3 to 1.4) 154.8 to 197.5 (17.6 to 22.5) 77.4 to 95.0 (8.8 to 10.8) 276.2 to 344.8 (31.4 to 39.2) 11.4 to 12.3 (1.3 to 1.4) Electrical Installation 2 - 6 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Recommended Wire Size AWG (mm2) *2 Wire Type 3 (30) 4 (22) 4 (22) 2 (38) 3 (30) Application Dependent 4 (22) 1/0 (60) 1 (50) Application Dependent 4 (22) 2/0 (70) Application Dependent 4 (22) 4/0 (100) 3/0 (80) Application Dependent 2 (38) 16 (1.25) 250 (125) 4/0 (100) Application Dependent 1 (50) 16 (1.25) 2/0 × 2P (70 × 2P) 1/0 × 2P (60 × 2P) Application Dependent 2/0 (70) 16 (1.25) 600Vac UL Approved vinyl-sheathed or equivalent Table 2.2 480Vac Wire Sizes and Connector Specifications (Continued) Drive Model CIMR-F7U Terminal Symbol R/L1, S/L2, T/L3, , Terminal Screws Clamping Torque lb. in. (N•m) M10 154.8 to 197.5 (17.6 to 22.5) 1, R1/L11, S1/L21, T1/L33 U/T1, V/T2, W/T3 4132 M8 3 M12 r/l1, s200/l2200, s400/l2400 R/L1, S/L2, T/L3, , M4 1, R1/L11, S1/L21, T1/L33 M12 U/T1, V/T2, W/T3 4160 M8 3 M12 r/l1, s200/l2200, s400/l2400 M4 77.4 to 95.0 (8.8 to 10.8) 276.2 to 344.8 (31.4 to 39.2) 11.4 to 12.3 (1.3 to 1.4) 276.2 to 344.8 (31.4 to 39.2) 77.4 to 95.0 (8.8 to 10.8) 276.2 to 344.8 (31.4 to 39.2) 11.4 to 12.3 (1.3 to 1.4) R/L1, S/L2, T/L3, U/T1, V/T2, W/T3, R1/L11, S1/L21, T1/L33 , N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 1 M16 4185 Possible Wire Sizes AWG (mm2) * 1 693.9 to 867.4 (78.4 to 98.0) 3 N/A N/A N/A r/l1, s200/l2200, s400/l2400 M4 11.4 to 12.3 (1.3 to 1.4) N/A R/L1, S/L2, T/L3, R1/L11, S1/L21, T1/L33 N/A U/T1, V/T2, W/T3 N/A , M16 1 4220 693.9 to 867.4 (78.4 to 98.0) N/A N/A 3 N/A r/l1, s200/l2200, s400/l2400 M4 11.4 to 12.3 (1.3 to 1.4) N/A R/L1, S/L2, T/L3, R1/L11, S1/L21, T1/L33 N/A U/T1, V/T2, W/T3 N/A , M16 1 4300 693.9 to 867.4 (78.4 to 98.0) N/A N/A 3 N/A r/l1, s200/l2200, s400/l2400 M4 11.4 to 12.3 (1.3 to 1.4) N/A Recommended Wire Size AWG (mm2) *2 Wire Type 3/0 × 2P (80 × 2P) 2/0 × 2P (70 × 2P) Application Dependent 4/0 (100) 16 (1.25) 4/0 × 2P (100 × 2P) 3/0 × 2P (80 × 2P) Application Dependent 1/0 × 2P (60 × 2P) 16 (1.25) 300 x 2P (150 x 2P) 600 X 2P (325 X 2P) Application Dependent 3/0 x 2P (80 x 2P) 16 (1.25) 500 x 2P (325 x 2P) 400 x 2P (200 x 2P) 250 X 4P (125 X 4P) Application Dependent 250 x 2P (125 x 2P) 16 (1.25) 250 x 4P (125 x 4P) 4/0 x 4P (100 x 4P) 400 X 4P (200 X 4P) Application Dependent 400 x 2P (203 x 2P) 16 (1.25) 600Vac UL Approved vinyl-sheathed or equivalent *1 Wire size range provided for Drives using insulated screw-type terminal blocks. All other models require the use of UL listed connectors. Refer to Table 2.3. *2 Recommended wire sizes are based on the normal duty (ND) current ratings and NEC Article 310 Table 310.16, 75 Degree Celsius copper or equivalent. When sizing wiring based on the heavy duty (HD) current ratings, consult NEC Article 430 and any other applicable codes. Determine the wire size for the main circuit so that line voltage drop is within 2% of the rated voltage. Line IMPORTANT voltage drop is calculated as follows: Line voltage drop (V) = 3 x wire resistance (Ω/km) x wire length (m) x current (A) x 10-3 Electrical Installation 2 - 7 The use of UL listed closed-loop connectors or CSA certified ring connectors sized for the selected wire gauge is recommended to maintain proper clearances when wiring the Drive. Install connectors per manufacturer recommendation using the correct crimp tool. Table 2.3 lists a suitable closed-loop connector manufactured by JST Corporation. Table 2.3 Recommended Connectors for Terminal Connections Wire Size * AWG mm2 20 0.5 18 16 14 12 / 10 8 6 4 3/2 M3.5 1.25 - 3.7 1.25 2 3.5 / 5.5 8 14 22 30 / 38 50 / 60 2/0 70 3/0 80 250 / 300MCM Ring Tongue (R-Type) Closed-Loop Connectors (Lugs) JST Corporation Part Numbers ** 0.75 1 / 1/0 4/0 Terminal Screw 100 125 / 150 400MCM 200 650MCM 325 M4 1.25 - 4 M3.5 1.25 - 3.7 M4 1.25 - 4 M3.5 1.25 - 3.7 M4 1.25 - 4 M3.5 2 - 3.7 M4 2-4 M5 2-5 M6 2-6 M8 2-8 M4 5.5 - 4 M5 5.5 - 5 M6 5.5 - 6 M8 5.5 - 8 M5 8-5 M6 8-6 M8 8-8 M5 14 - 5 M6 14 - 6 M8 14 - 8 M5 22 - 5 M6 22 - 6 M8 22 - 8 M6 38 - 6 M8 38 - 8 M8 60 - 8 M10 60 - 10 M8 70 - 8 M10 70 - 10 M10 80 - 10 M16 80 - 16 M10 100 - 10 M12 100 - 12 M16 100 - 16 M10 150 - 10 M12 150 - 12 M16 150 - 16 M12 200 - 12 M12 x 2 325 - 12 M16 325 - 16 * Wire sizes are based on 75 degrees Celsius copper wire. ** Equivalent connector can be used. Electrical Installation 2 - 8 Main Circuit Terminal Functions Main circuit terminal functions are summarized according to terminal symbols in Table 2.4. Wire the terminals correctly for the desired purpose. Table 2.4 Main Circuit Terminal Functions (208-240Vac and 480Vac) Model: CIMR-F7UFFFF Terminal Designation 208-240Vac 480Vac Purpose R/L1, S/L2, T/L3 20P4 to 2110 R1/L11, S1/L21, T1/L31 2022 to 2110 4030 to 4300 Drive outputs U/T1, V/T2, W/T3 20P4 to 2110 40P4 to 4300 DC power input 1, 20P4 to 2110 40P4 to 4300 Braking Resistor Unit Connection B1, B2 20P4 to 2018 40P4 to 4018 Braking Transistor Unit Connection 3, 2022 to 2110 4022 to 4300 DC link choke connection 1, Main circuit power input 2 Ground 40P4 to 4300 20P4 to 2018 40P4 to 4018 20P4 to 2110 40P4 to 4300 Main Circuit Configurations 208-240Vac The 208-240Vac main circuit configurations of the Drive are shown in Table 2.5. Table 2.5 Drive Main Circuit Configurations 208-240Vac CIMR-F7U20P4 to 2018 *1 { CIMR-F7U2022 and 2030 *1, 2 Power supply { Control circuits Power supply CIMR-F7U2037 to 2110 *1, 2 { Power supply Control circuits *1 Input fuses or molded case circuit breakers are required for proper branch circuit protection for all Drives. Failure to use recommended fuses/circuit breakers (See Appendix E) may result in damage to the Drive and/or personal injury. *2 Consult your Yaskawa representative before using 12-pulse rectification circuit configuration. Electrical Installation 2 - 9 Control circuits Main Circuit Configurations 480Vac The 480Vac main circuit configurations of the Drive are shown in Table 2.6. Table 2.6 Drive Main Circuit Configurations 480Vac CIMR-F7U4022 to 4055 CIMR-F7U40P4 to 4018 *1 { *1, 2 { Control circuits Power supply Power supply Control circuits CIMR-F7U4075 to 4300 3 *1, 2 { Power supply Control circuits *1 Input fuses or molded case circuit breakers are required for proper branch circuit protection for all Drives. Failure to use recommended fuses/circuit breakers (See Appendix E) may result in damage to the Drive and/or personal injury. *2 Consult your Yaskawa representative before using 12-pulse rectification circuit configuration. Electrical Installation 2 - 10 Cable Length between Drive and Motor The F7 should be installed as close as possible to the motor to minimize the length of the load side power cable needed between the Drive and motor. If the cable between the Drive and the motor is long, the high-frequency leakage current will increase, causing the Drive output current to increase as well. This may affect peripheral devices. To prevent this, reduce cable length, or if necessary, adjust the carrier frequency (set in parameter C6-02) as shown in Table 2.7. The line side power cables, load side power cables and control wiring should be run in seperate conduit. Careful attention to this recommended design practice will avoid many potential motor and Drive related problems. Table 2.7 Motor Cable Length vs. Carrier Frequency Motor Cable Length 164 ft. (50m) maximum 328 ft. (100m) maximum More than 328 ft.(100m) Carrier Frequency 15kHz maximum 10kHz maximum 5kHz maximum Ground Wiring Observe the following precautions when connecting the ground wire: 1. 208-240Vac Drives should have a ground connection with resistance of less than 100Ω . 2. 480Vac Drives should have a ground connection with resistance of less than 10Ω . 3. Do not share the ground wire with other devices, such as welding machines or large-current electrical equipment. 4. Always use a ground wire that complies with technical standards on electrical equipment and minimize the length of the ground wire. Leakage current flows through the Drive. Therefore, if the distance between the ground rod and the ground terminal is too long, potential on the ground terminal of the Drive could develop. 5. When using more than one Drive, be careful not to loop the ground wire. See Fig 2.4. NOT OK OK Fig 2.4 Ground Wiring Examples Electrical Installation 2 - 11 Dynamic Braking Connections General Dynamic braking (DB) enables the motor to be brought to a smooth and rapid stop. This is achieved by dissipating the regenerative energy of the AC motor across the resistive components of the Dynamic Braking option. For further details on dynamic braking operation, see the instruction sheet shipped with dynamic braking components. Drives F7U20P4 thru F7U2018 and F7U40P4 thru F7U4018 have an integral braking transistor and require the addition of a Remote Mounted Resistor Unit or a Heat Sink Mount Resistor (ERF). All higher rated Drives require the use of a Braking Transistor Unit (CDBR) and a Remote Mount Resistor Unit. Remote Mount Resistor Units typically mount outside of the electrical enclosure. Braking Transistor Units mount inside of the electrical enclosure. Heat Sink Mount Resistors mount to the back of the Drive, attaching directly to the heat sink. Table 2.8 Heat Sink Mount Dynamic Braking Resistor - 3% Duty Cycle Drive Rated Input Vac 208-240 480 Heat Sink Mount Resistor Part No. Qty. Reqd. Resistance (Ohms) Power (Watts) Approx. Braking Torque (%) 20P4 R7505 1 200 150 20P7 R7505 1 200 21P5 R7504 1 22P2 R7503 23P7 Drive Model No. F7U Dimensions (Inches) Height Width Depth 220 7.16 1.73 0.51 150 125 7.16 1.73 0.51 100 150 125 7.16 1.73 0.51 1 70 150 120 7.16 1.73 0.51 R7510 1 62 150 100 7.16 1.73 0.51 40P4 R7508 1 750 150 230 7.16 1.73 0.51 40P7 R7508 1 750 150 130 7.16 1.73 0.51 41P5 R7507 1 400 150 125 7.16 1.73 0.51 42P2 R7506 1 300 150 115 7.16 1.73 0.51 43P7 R7505 1 200 150 110 7.16 1.73 0.51 Installation This option should only be installed by a technically qualified individual who is familiar with this type of equipment and the hazards involved. WARNING Hazardous voltages can cause severe injury or death. Lock all power sources feeding the Drive in the “OFF” position. Failure to follow these installation steps may cause equipment damage or personal injury. Preliminary Procedures 1. Disconnect all electrical power to the Drive. 2. Remove Drive front cover. 3. Use a voltmeter to verify that voltage is disconnected from incoming power terminals and that the DC bus has dissipated. Electrical Installation 2 - 12 Heat Sink Mount Resistor Installation 1. Remove the Drive from its mounting for access to the rear of the heat sink. 2. Attach the Heat Sink Mount Resistor on the back of the Drive’s heat sink with screws M4 x 10mm (0.7mm pitch), as shown in figure below. 3. Remove the rubber plug and run the braking resistor wires into the hole that leads to the terminal block. 4. Reinstall the Drive in its mounting position. 5. Connect the leads from the Heat Sink Mount Resistor to the Drive terminals B1 and B2. 6. Proceed to “Adjustments” section on page 2-18. Fig 2.5 Attaching Heat Sink Mount Resistor on Heat Sink Electrical Installation 2 - 13 Remote Mount Resistor Unit Installation Using Internal Braking Transistor (for F7U20P4 thru F7U2018 and F7U40P4 thru F7U4018) Since the Remote Mount Resistor Unit generates heat during dynamic braking operation, install it in a location away from other equipment. 1. Install the Remote Mount Resistor Unit to a noncombustible surface, maintaining a minimum 1.97 inches (50mm) clearance on each side and a minimum 7.87 inches (200mm) clearance on top. 2. Remove the Remote Mount Resistor Unit cover to access its terminal block. Connect the Remote Mount Resistor Unit to the Drive and to external control circuitry according to the figure below. Table 2.9 Wire Size for Remote Mount Resistor Unit Terminals B, P, R1, R2 1, 2* Wire Size (AWG) 12-10 18-14* Wire Type 600V Ethylene propylene rubber insulated, or equivalent Terminal Screw M4 * Power Leads for the Remote Mount Resistor Unit generate high levels of electrical noise - these signal leads must be grouped separately. IM S3 SN‡ 3% DUTY CYCLE RESISTOR ASSEM(R2)* (R1)* 120 VAC * Terminal markings in parentheses are for resistors manufactured by Powerohm Resistors Inc. ‡ Applies when SC is jumpered to SP and S3 is programmed as External Fault. Fig 2.6 Wiring Remote Mount Resistor Unit (for F7U20P4 thru F7U2018 and F7U40P4 thru F7U4018) 3. Reinstall and secure Remote Mount Resistor Unit cover and Drive front cover. 4. Proceed to “Adjustments” section on Page 2-18. Electrical Installation 2 - 14 Braking Transistor Unit(s) and Remote Mount Resistor Unit(s) Installation (for F7U2022 thru F7U2110 and F7U4022 thru F7U4300) Since the Remote Mount Resistor Unit generates heat during dynamic braking operation, install it to a noncombustible surface in a location away from other equipment. Select mounting locations for Braking Transistor Unit(s) and Remote Mount Resistor Unit(s) so that wiring between the Drive and the Braking Transistor Unit is 16 feet (5m) or less, and the wiring between each Braking Transistor Unit and its associated Remote Mount Resistor Unit, is less than 33 feet (10m). 1. Mount the Braking Transistor Unit(s) on a vertical surface. The Braking Transistor Unit requires a minimum of 1.18 inches (30mm) clearance on each side and a minimum 3.94 inches (100mm) clearance top and bottom. Attach the Remote Mount Resistor Unit maintaining a minimum 1.97 inches (50mm) clearance on each side and a minimum 7.87 inches (200mm) clearance on top. 2. In each Braking Transistor Unit, set the nominal line voltage jumper plug to the correct setting for the installation; this is factory set at the 220V/440V/575V position. To access jumper plugs, remove the plastic cover. WARNING • Be sure to set the nominal line voltage selection jumper to match the level of the AC supply being applied to the Drive. • Failure to do so may result in improper operation. 3. If multiple Braking Transistor Units are being installed, the unit closest to the Drive should have the Slave/Master jumper plug set to the “Master” position (factory setting); all others must have this jumper plug set to the “Slave” position. 4. If a single Braking Transistor Unit and Remote Mount Resistor Unit are being installed, connect them to the Drive and external control circuitry according to the chart below and Fig 2.7. 5. Power leads for the Remote Mount Resistor Unit generate high levels of electrical noise - these power leads must be grouped separately from all other leads. Table 2.10 Wire Size for Remote Mount Resistor Unit and Braking Transistor Unit Name Braking Transistor Unit (Models CDBR-2015B, -2022B, -4030B, -4045B) Braking Transistor Unit (Model CDBR-2045, -4090) Braking Transistor Unit (Model CDBR-2110) Circuit Control 1 4 0 2 3 5 6 P, Po, N, B 2 3 5 6 s r 1 4 2 5 3 6 s r 1 4 2 5 3 6 Wire Type Terminal Screw 600V vinyl sheathed wire or equivalent M4 18-14 (0.75-2) 12-10 (3.5-5.5) 18-14 (0.75-2) 600V vinyl sheathed wire or equivalent B P 12-10 (3.5-5.5) Control 1 2 18-14 (0.75-2) *1 For wire size of 8-6 (8-14), use UL1283 heat-resistant vinyl-insulated wire or equivalent. *2 M4 for Models LKEB-20P7 to -27P5 or -40P7 to -4015. M5 for Models LKEB-2011 to -2022 or -4018 to -4045. Electrical Installation 2 - 15 M4 M4 M6 600V vinyl sheathed wire or equivalent 18-14 (0.75-2) Main M5 M6 600V vinyl sheathed wire or equivalent 18-14 (0.75-2) 4 (22) 8-6 (8-14) *1 12-10 (3.5-5.5) P, Po, N, B Main 12-10 (3.5-5.5) 4 (22) 8-6 (8-14) *1 12-10 (3.5-5.5) P, Po, N, B Main Control Braking Resistor Unit (Model LKEB-F) 1 4 Main Control Braking Transistor Unit (Model CDBR-4220) 0 Main Control Wire Size AWG (mm2) Terminals 600V vinyl sheathed wire or equivalent M4 M4 (M5) *2 M4 IM S3 SN‡ 0 R1 0 R2 REMOTE MOUNT RESISTOR UNIT ‡ Applies when SC is jumpered to SP and S3 is programmed as External Fault. Fig 2.7 Wiring Single Braking Transistor Unit and Remote Mount Resistor Unit to Drive (F7U2022 thru F7U2110 and F7U4022 thru F7U4300) Electrical Installation 2 - 16 6. If two or more Braking Transistor Units and Remote Mount Resistor Units are being installed, connect them to the Drive and to external circuitry according to Fig 2.8. IM SN‡ S3 R1 R2 0 0 0 0 0 0 R1 R2 R2 0 R1 0 R1 R2 0 0 R1 R2 0 0 ‡ Applies when SC is jumpered to SP and S3 is programmed as External Fault. Note: Connect only the number of braking transistor units and remote mount resistor units required for the application. Fig 2.8 Wiring Multiple Braking Transistor Units and Remote Mount Resistor Units to Drive (F7U2022 thru F7U2110 and F7U4022 thru F7U4300) Electrical Installation 2 - 17 Adjustments 7. All Drives: Program Parameter L3-04 to “0” or “3” to disable stall prevention during deceleration. 8. Heat Sink Mount Resistor Only: Program L8-01 to “1” to enable overheat protection for heat sink mount braking resistor. Operation Check 9. During dynamic braking, verify that the “BRAKE” lamp inside the Braking Unit is lit. This lamp illuminates only when dynamic braking is activating (during quick deceleration). 10.During dynamic braking, ensure that the required deceleration characteristic is obtained. If not, contact Yaskawa for assistance. 11.Reinstall and secure covers on the Braking Transistor Units, Remote Mount Resistor Units, and the Drive. Electrical Installation 2 - 18 Terminal Connections Connections to Drive terminals are shown in Fig 2.9. Digital Inputs 1-2 24Vdc, 8mA External Fault 2-Wire Control Fault Reset Multi-function Digital Inputs 3-8 24Vdc, 8mA Multi-Step Ref 1 Multi-Step Ref 2 Jog Reference Baseblock Stop switch (NC contact) Operation switch (NO contact) S1 S2 Fwd/Rev S5 SN 3-Wire Control Run command (run on momentary close) Stop command (stop on momentary open) Forward/reverse command (multi-function input) Fig 2.9 Terminal Connections Sequence input common Electrical Installation 2 - 19 Control Wiring Control Circuit Terminal Functions The factory default functions of the control circuit terminals for 2-wire control are shown in Table 2.11. Type No. S1 S2 S3 S4 S5 Digital Input Signals S6 S7 S8 SN Analog Input Signals SC Digital input supply common Digital input photocoupler SP Digital input supply +24Vdc +V +15Vdc power output +15Vdc power supply for analog inputs or transmitters. -V -15Vdc power output -15Vdc power supply for analog inputs or transmitters. A1 Analog input or speed command A2 Add to terminal A1 A3 Aux. frequency reference 1 AC Analog common Shield wire, optional ground line connection point 0 to +10Vdc/100% 0 to +/-10Vdc / 100% (H3-01) Multi-function 4 to 20mA/100% analog input 2. 0 to +10Vdc / 100% (H3-08) Function set by H3-09. Multi-function 0 to +10Vdc/100% analog input 3. 0 to +/-10Vdc / 100% (H3-04) Function set by H3-05 – E(G) M1 M2 M3 Digital Output Signals Table 2.11 Control Circuit Terminals Default Function Description Forward run/stop command Forward run when CLOSED; stopped when OFF. Reverse run/stop command Reverse run when CLOSED; stopped when OFF. External fault input Fault when CLOSED. Fault reset Reset when CLOSED. Multi-step speed reference 1 Auxiliary frequency reference Multi-function (Master/auxiliary switch) when CLOSED. digital inputs. Multi-step setting 2 when Multi-step speed reference 2 Functions set by CLOSED. H1-01 to H1-06. Jog frequency reference Jog frequency when CLOSED. Shuts off Drive’s output when External baseblock N.O. CLOSED. M4 – MA MB Zero Speed (N.O. contact) CLOSED when below minimum frequency. Multi-function digital output. Function set by H2-02. Frequency agree (N.O. contact) CLOSED when set frequency matches output frequency. Multi-function digital output. Function set by H2-03. Fault output signal (SPDT) MA/MC: CLOSED during fault condition MB/MC: OPEN during fault condition MC Electrical Installation 2 - 20 +15Vdc (Max. current: 20mA) -15Vdc (Max. current: 20mA) 0 to +10V(20kΩ) 4 to 20mA(250Ω) 0 to +/-10V(20kΩ) 0 to +/-10V(20kΩ) – – Multi-function digital output. Function set by H2-01. M5 M6 24Vdc, 8mA Photocoupler isolation Refer to Table 2.15 for connection details. CLOSED during operation. During run (N.O. contact) Signal Level Form A Dry contacts capacity: 1A max. at 250Vac 1A max. at 30Vdc Form C Dry contacts capacity: 1A max. at 250Vac 1A max. at 30Vdc Type No. FM Analog Output Signals AM AC Table 2.11 Control Circuit Terminals (Continued) Default Function Description Multi-function 0 to +10Vdc / 100% frequency analog output 1. Output frequency -10 to +10Vdc / 100% frequency Function set by 4 to 20mA / 100% frequency H4-01. 0 to +10Vdc / 100% Drive's rated Multi-function output current analog output 2. -10 to +10Vdc / 100% Drive's Output current rated output current Function set by 4 to 20mA / 100% Drive's rated H4-04. output current Analog common Signal Level 0 to +10Vdc -10 to +10Vdc (Max current 2mA) 4 to 20mA, 500Ω - – 0 to 32kHz (3kΩ) ±5% High level voltages 3.5 to 13.2 RP Pulse input Pulse input frequency reference Function set by H6-01. Pulse I/O RS-485/ 422 MP Pulse monitor R+ RS+ SIG Modbus communication input Modbus communication output Pulse output frequency Function set by H6-06. For 2-wire RS-485, jumper R+ and S+ and jumper R- and S-. Signal common – Low level voltages 0.0 to 0.8 Duty Cycle (on/off) 30% to 70% 0 to 32kHz +5V output (Load: 1.5kΩ) Differential input, PHC isolation Differential output, PHC isolation – Table 2.12 Terminal Numbers and Wire Sizes (Same for all Drives) Terminals Terminal Screws Tightening Torque lb-in (N•m) Possible Wire Sizes AWG (mm2) Recommended Wire Size AWG (mm2) S1, S2, S3, S4, S5, S6, S7, S8, SN, SC, SP, +V, -V, A1, A2, A3, AC, RP, M1, M2, M3, M4, M5, M6, MA, MB, MC, FM, AC, AM, MP, R+, R-, S+, S-, IG Phoenix type *3 4.2 to 5.3 (0.5 to 0.6) Stranded wire: 26 to 16 (0.14 to 1.5) 18 (0.75) E(G) M3.5 7.0 to 8.8 (0.8 to 1.0) 20 to 14 (0.5 to 2) 12 (1.25) Wire Type • Shielded, twisted-pair wire*1 • Shielded, polyethylene-covered, vinyl sheath cable*2 *1 Use shielded twisted-pair cables to wire an external speed command. *2 Yaskawa recommends using straight solderless terminals on digital inputs to simplify wiring and improve reliability. *3 Yaskawa recommends using a thin-slot screwdriver with a 3.5mm blade width. Electrical Installation 2 - 21 DIP Switch S1 and Jumper CN15 S1 CN15 Fig 2.10 DIP Switch S1 and Jumper CN15 Location Dip Switch S1 DIP Switch S1 is described in this section. The functions of DIP switch S1 are shown in Table 2.13. S1 ON/OFF position 1 2 DIP Switch S1 located on terminal board. Fig 2.11 DIP Switch S1 Function Table 2.13 DIP Switch S1 Name Function Setting S1-1 RS-485 and RS-422 terminating resistance S1-2 Input method for analog input A2 OFF: No terminating resistance ON: Terminating resistance of 110Ω Factory Default = OFF OFF: 0 to 10Vdc or -10 to 10Vdc (internal resistance: 20KΩ) ON: 4-20mA (internal resistance: 250Ω) Factory Default = ON Jumper CN15 Jumper CN15 is described in this section. The jumper position of CH1 and CH2 determines the signal level of the multi-function analog output FM and AM, respectively. The functions and positions of CN15 are shown in Table 2.14. Table 2.14 Jumper CN15 Configuration Options Jumper CN15 Configuration Analog Output Monitor Configuration CH1 CH2 Voltage Output (0-10Vdc) for terminals FM-AC (CH1) and AM-AC (CH2) CH1 CH2 Current Output (4-20mA) for terminals FM-AC (CH1) and AM-AC (CH2) CH1 CH2 Voltage Output (0-10Vdc) for terminals FM-AC (CH1) Current Output (4-20mA) for terminals AM-AC (CH2) CH1 CH2 Current Output (4-20mA) for terminals FM-AC (CH1) Voltage Output (0-10Vdc) for terminals AM-AC (CH2) Electrical Installation 2 - 22 Sinking/Sourcing Mode The multi-function digital input terminal logic can be switched between sinking mode (0Vdc common) and sourcing mode (+24Vdc common) by using the terminals SN, SC, and SP. An external power supply can also be connected, providing more freedom in signal input methods. Table 2.15 Sinking/Sourcing Mode and Input Signals Internal Power Supply – Sinking Mode IP24V (+24Vdc) External Power Supply – Sinking Mode External +24Vdc IP24V (+24Vdc) (Factory Default) Internal Power Supply – Sourcing Mode External Power Supply – Sourcing Mode External +24Vdc IP24V (+24Vdc) Electrical Installation 2 - 23 IP24V (+24Vdc) Control Circuit Wiring Precautions Observe the following precautions when wiring control circuits: 1. Separate control wiring from power/motor wiring (terminals R/L1, S/L2, T/L3, U/T1, V/T2, W/T3, B1, B2, and 3) and other high-power lines. , 1, 2, 2. Separate wiring for control circuit terminals MA, MB, MC, M1, M2, M3, M4, M5, and M6 (digital outputs) from wiring to other control circuit terminals. 3. If using an optional external power supply, ensure it is a UL Listed Class 2 power supply source. 4. Use twisted-pair or shielded twisted-pair cables for control circuits to prevent operating faults. Prepare cable ends as shown in Fig 2.12. 5. Connect the shield wire to terminal E(G). 6. Insulate the shield with tape to prevent contact with other signal lines and equipment. Shield sheath Insulation Do not connect here. Connect to shield sheath terminal E(G) at Drive Insulate with tape Fig 2.12 Preparing the Ends of Twisted-pair Cables Control Circuit Wire Sizes For remote operation, keep the length of the control wiring to 50m or less. Separate the control wiring from high-power lines (input power, motor leads or relay sequence circuits) to reduce noise induction from peripheral devices. When setting speed commands from an external speed potentiometer, use shielded twisted-pair wires and ground the shield to terminal E(G), as shown above. Terminal numbers and wire sizes are shown in Table 2.12. Wiring Checks After all wiring is completed, perform the following checks: 1. Is all wiring correct? 2. Have all wire clippings, screws or other foreign material been removed from the Drive enclosure? 3. Are all terminal screws tight? Electrical Installation 2 - 24 Field Wiring Diagram Use this diagram to document field wiring. It may be helpful to copy this page. Fig 2.13 Field Wiring Diagram Electrical Installation 2 - 25 Electromagnetic Compatibility (EMC) Introduction This section describes the measures necessary to comply with the EMC (Electro Magnetic Compatibility) Directive. The manual's installation and wiring instructions must be followed for compliance. Yaskawa products are tested by certified independent test laboratories for compliance toward the EMC Directive 89/336/EEC as amended by 91/263/EEC, 92/31/EEC, 93/68/EEC. The F7 series Drives meet/conform to the following standards: EN 61800-3: 1996, A11: 2000-01 EN 61000-4-5: 1995-03 VDE0847 Part 4-13: 1996 EN55011: 2000-05 EN 61000-4-6: 1996-97 IEC 61000-2-1: 1994 EN 61000-4-2: 1995-03 EN 61000-4-11: 1994 IEC 1000-4-27: 1997 EN 61000-4-3: 1997 CISPR 11: 1997 EN 61000-4-4: 1995-03 VDE0847 Part 4-28: 1997 Measures to Ensure Conformity of Installed Yaskawa Drives to EMC Directive Yaskawa Drives are not required to be installed in an EMC compatible enclosure. It is not possible to give detailed instructions for all possible types of installations; therefore, this manual provides general guidelines. All electrical equipment produces radio and line-borne interference at various frequencies. The power leads pass this on to the surrounding environment like an antenna. Connecting an item of electrical equipment (e.g. Drive) to a supply without a line filter can allow High Frequency (HF) or Low Frequency (LF) interference to penetrate the power distribution system. The basic countermeasures are isolation of the wiring of control and power components, proper grounding, and shielding of cables. A large contact area is necessary for low-impedance grounding of HF interference. The use of grounding straps, instead of cables, is therefore highly recommended. Cable shields must be connected with ground clips. CE certification for EMC can be achieved using the line filters specified in this manual and following the appropriate installation instructions. Cable Installation Measures against line-borne interference: Use a power cable with a well-grounded shield. Use a shielded motor cable not exceeding 82 feet (25m) in length. Arrange all grounds to maximize the end of the lead area in contact with ground (e.g. metal plate). Use a shielded cable with braided shield and ground the maximum possible area of the shield. It is advisable to ground the shield by connecting the cable to the ground plate with metal clips (see Fig 2.14). Ground clip Ground plate Fig 2.14 Grounding Surface Layout Electrical Installation 2 - 26 The grounding surfaces must be highly conductive bare metal. Remove any varnish or paint from grounding surfaces. Be sure to ground the motor of the machine/application. Line filter and Drive must be mounted on the same metal plate. Mount the two components as close to each other as possible, with cables kept as short as possible, not exceeding 15.75” (see Fig 2.15). See Table 2.16 for recommended filters. Grounding (Remove varnish or paint) Metal plate F7 Drive EMC Filter Cable Max. Length: 15.75” Motor Cable Max. Length: 82 feet Grounding (Remove varnish or paint) IM Fig 2.15 EMC Filter Layout Electrical Installation 2 - 27 Recommended EMC Filters Table 2.16 Recommended EMC Filters EMC Filter Drive Model CIMR-F7U Model Number EN 55011 Class* Current Rating Weight lb. (kg) Dimensions inches (mm) 200Vac Class 20P4 20P7 21P5 FS5972-10-07 B 10A 2.43 (1.1) 5.500 x 13 x 1.875 (141 x 330 x 46) 22P2 FS5972-18-07 B 18A 2.87 (1.3) 5.500 x 13 x 1.875 (141 x 330 x 46) 23P7 25P5 FS5973-35-07 B 35A 3.09 (1.4) 5.500 x 13 x 1.875 (141 x 330 x 46) 27P5 FS5973-60-07 B 60A 6.61 (3) 2011 FS5973-60-07 or FS5973-100-07 B 60A or 100A 6.61 (3) or 10.8 (4.9) FS5973-100-07 A 100A 10.8 (4.9) 9.3125 x 16 x 3.125 (236 x 408 x 80) FS5973-130-35 A 130A 9.48 (4.3) 3.5315 x 14.40625 x 7 (90 x 366 x 180) FS5973-160-40 A 160A 13.23 (6) 4.750 x 17.750 x 6.6875 (120 x 451 x 170) FS5973-240-37 A 240A 24.25 (11) 5.125 x 24 x 9.4375 (130 x 610 x 240) FS5973-500-37 A 500A 42.99 (19.5) 11.81 x 22.20 x 6.30 (300 x 564 x 160) 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110 8 x 14 x 2.375 (206 x 355 x 60) 8 x 14 x 2.375 (206 x 355 x 60) or 9.3125 x 16 x 3.125 (236 x 408 x 80) 400Vac Class 40P4 40P7 41P5 42P2 43P7 44P0 45P5 FS5972-10-07 or FS5972-18-07 10A 2.43 (1.1) B 10A or 18A 2.43 (1.1) or 2.87 (1.3) FS5972-18-07 B 18A 2.87 (1.3) 47P5 FS5972-21-07 or FS5972-35-07 B 21A or 35A 4011 FS5972-35-07 B 35A FS5972-60-07 B 60A 8.82 (4) 9.250 x 16 x 2.50 (236 x 408 x 65) FS5972-70-52 B 70A 7.5 (3.4) 3 x 13 x 7.250 (80 x 329 x 185) 4015 4018 4022 4030 FS5972-10-07 Electrical Installation 2 - 28 3.97 (1.8) or 4.63 (2.1) 4.63 (2.1) 5.500 x 13 x 1.875 (141 x 330 x 46) 5.50 x 13 x 1.875 (141 x 330 x 46) 8.11 x 13.98 x 1.97 (206 x 355 x 50) 8.11 x 13.98 x 1.97 (206 x 355 x 50) Table 2.16 Recommended EMC Filters (Continued) EMC Filter Drive Model CIMR-F7U EN 55011 Class* Current Rating Weight lb. (kg) B 4045 FS5972-100-35 or FS5972-130-35 100A or 130A 9.92 (4.5) or 10.36 (4.7) 4055 FS5972-130-35 B 130A 4075 FS5972-170-40 B 170A 4090 FS5972-250-37 or FS3359-250-28 A 250A 24.25 (11) or 15.43 (7) A 400A 4160 FS5972-400-99 or FS3359-400-99 23.15 (10.5) or 40.78 (18.5) 4185 FS5972-410-99 A 410A 23.15 (10.5) 4220 FS5972-600-99 A 600A 4300 FS5972-800-99 A 800A 4037 4110 4132 Model Number 10.36 (4.7) 13.23 (6) 24.25 (11) 68.34 (31) Dimensions inches (mm) 3.54 x 12.83 x 5.9 (90 x 326 x 150) or 3.54 x 14.375 x 7 (90 x 366 x 180) 3.54 x 14.375 x 7 (90 x 366 x 180) 4.75 x 17.75 x 6.6675 (120 x 451 x 170) 5.125 x 24 x 9.475 (130 x 610 x 240) or 9.05 x 11.80 x 4.92 (230 x 300 x 125) 10.24 x 15.20 x 4.53 (260 x 386 x 115) or 11.81 x 24.01 x 6.30 (300 x 610 x 160) 10.24 x 15.20 x 4.53 (260 x 386 x 115) 10.24 x 15.20 x 5.31 (260 x 386 x 135) 11.81 x 28.19 x 6.30 (300 x 716 x 160) * Maximum Voltage: 480Vac 3-phase Ambient Temperature: 45 Degrees Celsius (maximum) Maximum motor cable length: 50m Class B, 50m Class A Permissible emission of power drive systems for commercial and light environment (EN61800-3, A11) (General availability, 1st environment) Electrical Installation 2 - 29 Installing and Wiring Option Boards Option Board Models and Specifications Up to three Option Boards can be mounted in the Drive. You can mount one board into each of the three option slots on the control board (A, C, and D) shown in Fig 2.16. The following Table 2.17 lists the type of Option Boards and their specifications. Table 2.17 Option Board Specifications Option Board PG Speed Control Boards Model Specifications Mounting Location PG-A2 Single open-collector feedback A (4CN) PG-B2 Single A/B open collector encoder feedback A (4CN) PG-D2 Single line-driver feedback A (4CN) PG-X2 Single A/B/Z line-driver encoder feedback A (4CN) PG-W2 Dual A/B/Z line-driver encoder feedback A (4CN) AI-14U Analog input 0 to 10Vdc (20kΩ), 1 channel 4 to 20mA (250Ω), 1 channel Input resolution: 14-bit C (2CN) AI-14B Analog input 0 to 10Vdc (20kΩ) 4 to 20mA (250Ω), 3 channels (V or I) Input resolution: 13-bit plus sign bit C (2CN) AI-14B2 Isolated analog input 0 to 10Vdc (20kΩ) 4 to 20mA (250Ω), 3 channels (V or I) Input resolution: 13-bit plus sign bit C (2CN) DI-08 8-bit digital input C (2CN) DI-16H2 16-bit digital input C (2CN) Speed Reference Boards DeviceNet Communications Board SI-NX DeviceNet communications C (2CN) Profibus-DP Communications Board SI-PX Profibus-DP communications C (2CN) InterBus-S Communications Board SI-RX InterBus-S communications C (2CN) CANopen Communications Board SI-SX CANopen communications C (2CN) AO-08 Analog output, 8-bit 2 channels D (3CN) AO-12 Analog output, 11-bit plus sign bit, 2 channels D (3CN) Isolated analog output, 11-bit plus sign bit, 2 channels D (3CN) Six photocoupler outputs and 2 relay outputs D (3CN) DO-02C 2 relay outputs D (3CN) PO-36F Pulse-train output D (3CN) Analog Monitor Boards AO-12B DO-08 Digital Output Boards Electrical Installation 2 - 30 Installation Before mounting an Option Board, remove power from the Drive and wait for the CHARGE LED to go out. Remove the Digital Operator, front cover, and option clip. Option Clip can be easily removed by squeezing the protruding portions of the clip and then pulling it out. Then, mount the Option Board(s). The A Option Board uses a mounting spacer to secure the board to the control board. Insert the mounting spacer as shown in Fig 2.16. After installing an Option Board into slot C or D, insert the Option Clip to prevent the side with the connector from rising. Refer to documentation provided with the Option Board for detailed mounting instructions for option slots A, C, and D. 2CN (C Option Board connector) 4CN (A Option Board connector) A Option Board mounting spacer hole A Option Board mounting spacer (Provided with A Option Board) Mounting spacer C Option Board Option Clip (To prevent raising of C or D Option Board) D Option Board Mounting spacer A Option Board Mounting spacer 3CN (D Option Board connector) A Option Board (Note: C or D Option Board must be mounted before mounting A Option Board) Fig 2.16 Mounting Option Boards Electrical Installation 2 - 31 PG (Encoder) Feedback Board Terminal Specifications and Wiring Examples PG-A2 The terminal specifications for the PG-A2 are given in Table 2.18. Table 2.18 PG-A2 Terminal Specifications Terminal No. Contents Specifications 1 12Vdc (±5%), 200mA max. Power supply for pulse generator 2 0Vdc (GND for power supply) 3 Terminals for switching between12Vdc voltage input and open collector input. For open collector input, short across 3 and 4. +12V/open collector switching terminals 4 TA1 5 H: +4 to 12V; L: +1V max. (Maximum response frequency: 30kHz) A-phase pulse input terminals 6 Pulse input common 7 12Vdc (±10%), 20mA max. A-phase pulse monitor output terminals 8 TA2 (E) Pulse monitor output common Shield connection terminal - Wiring the PG-A2 Wiring examples are provided in the following figures for the PG-A2. Drive Branch Circuit Protection R/L1 U/T1 V/L2 V/T2 W/L3 W/T3 PG-A2 1 4CN 4CN 2 +12Vdc power supply 0Vdc power supply 3 4 TA1 E 5 6 E 7 TA2 (E) 12Vdc voltage input (A phase) Pulse 0Vdc Pulse monitor output 8 • Shielded twisted-pair wires must be used for signal lines. • Do not use the PG-A2's power supply for anything other than the pulse generator (encoder). Using it for another purpose can cause malfunctions due to noise. • The length of the pulse generator's wiring must not be more than 100 meters. Fig 2.17 PG-A2 Open-Collector Input Wiring - Sourcing PG Electrical Installation 2 - 32 Drive Branch Circuit Protection R/L1 U/T1 V/L2 V/T2 W/L3 W/T3 PG-A2 1 4CN 4CN 2 +12Vdc power supply 0Vdc power supply 3 4 TA1 E 5 6 E 7 TA2 (E) Open collector input (A phase) Pulse 0Vdc Pulse monitor output 8 • Shielded twisted-pair wires must be used for signal lines. • Do not use the PG-A2's power supply for anything other than the pulse generator (encoder). Using it for another purpose can cause malfunctions due to noise. • The length of the pulse generator's wiring must not be more than 100 meters. Fig 2.18 PG-A2 Open-Collector Input Wiring - Sinking PG Electrical Installation 2 - 33 PG-B2 The terminal specifications for the PG-B2 are given in Table 2.19. Table 2.19 PG-B2 Terminal Specifications Terminal No. 1 2 3 TA1 Contents Power supply for pulse generator A-phase pulse input terminals H: +8 to 12Vdc L: +1Vdc max. (Maximum response frequency: 30 kHz) Pulse input common 5 H: +8 to 12Vdc L: +1Vdc max. (Maximum response frequency: 30 kHz) 1 2 3 4 TA3 0Vdc (GND for power supply) 4 B-phase pulse input terminals 6 TA2 Specifications 12Vdc (±5%), 200mA max. (E) Pulse input common A-phase monitor output terminals B-phase monitor output terminals Open collector output, 24Vdc, 30mA max. A-phase monitor output common Open collector output, 24Vdc, 30mA max. B-phase monitor output common Shield connection terminal - Wiring the PG-B2 Wiring examples are provided in Fig 2.19 and Fig. 2.20 for the PG-B2. Drive R/L1 Branch S/L2 Circuit Protection T/L3 Power supply +12Vdc Power supply 0Vdc 4CN A-phase pulse input (+) A-phase pulse input (–) B-phase pulse input (+) B-phase pulse input (–) A-phase pulse monitor output B-phase pulse monitor output • Shielded twisted-pair wires must be used for signal lines. • Do not use the PG-B2's power supply for anything other than the pulse generator (encoder). Using it for another purpose can cause malfunctions due to noise. • The length of the pulse generator's wiring must not be more than 100 meters. • The direction of rotation of the PG can be set in parameter F1-05 (PG Rotation). The factory preset is for forward rotation, A-phase advancement. Fig 2.19 PG-B2 Open-Collector Input Wiring - Sourcing PG Electrical Installation 2 - 34 Drive Branch Circuit Protection Power supply +12 V Power supply 0 V A-phase pulse open-collector input B-phase pulse open-collector input A-phase pulse monitor output B-phase pulse monitor output • Shielded twisted-pair wires must be used for signal lines. • Do not use the PG-B2's power supply for anything other than the pulse generator (encoder). Using it for another purpose can cause malfunctions due to noise. • The length of the pulse generator's wiring must not be more than 100 meters. • The direction of rotation of the PG can be set in parameter F1-05 (PG Rotation). The factory preset is for forward rotation, A-phase advancement. Fig 2.20 PG-B2 Open-Collector Input Wiring - Sinking PG Electrical Installation 2 - 35 PG-D2 The terminal specifications for the PG-D2 are given in Table 2.20. Table 2.20 PG-D2 Terminal Specifications Terminal No. Contents Specifications 1 2 12Vdc (±5%), 200mA max.* Power supply for pulse generator 3 5Vdc (±5%), 200mA max.* 4 TA1 Line driver input (RS-422 level) Maximum response frequency: 300kHz Pulse input terminals 5 6 0Vdc (GND for power supply) Common terminal - 7 Pulse monitor output terminals Line driver output (RS-422 level) 8 TA2 (E) Shield connection terminal - * 5Vdc and 12Vdc cannot be used at the same time. Wiring the PG-D2 Wiring examples are provided in Fig 2.21 for the PG-D2. Drive R/L1 Branch S/L2 Circuit Protection T/L3 Power supply +12Vdc 4CN 4CN Power supply 0Vdc Power supply +5Vdc Pulse input + (A phase) Pulse input - (A phase) Pulse monitor output • Shielded twisted-pair wires must be used for signal lines. • Do not use the PG-D2's power supply for anything other than the pulse generator (encoder). Using it for another purpose can cause malfunctions due to noise. • The length of the pulse generator's wiring must not be more than 100 meters. Fig 2.21 PG-D2 Wiring Electrical Installation 2 - 36 PG-X2 The terminal specifications for the PG-X2 are given in Table 2.21. Terminal No. 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 (E) TA1 TA2 TA3 Table 2.21 PG-X2 Terminal Specifications Contents Specifications 12Vdc (±5%), 200mA max.* Power supply for pulse generator 0Vdc (GND for power supply) 5Vdc (±5%), 200mA max.* A-phase input terminals Line driver input (RS-422 level) Maximum response frequency: 300kHz B-phase input terminals Z-phase input terminals Common terminal 0Vdc (GND for power supply) A-phase output terminals B-phase output terminals Line driver output (RS-422 level) Z-phase output terminals Control circuit common Shield connection terminal Isolated control circuit GND - * 5Vdc and 12Vdc cannot be used at the same time. Wiring the PG-X2 Wiring examples are provided in Fig 2.22 for the PG-X2. Drive R/L1 S/L2 T/L3 Branch Circuit Protection R/L1 U/T1 S/L2 V/T2 T/L3 W/T3 4CN 4CN Power supply +12Vdc Power supply 0Vdc Power supply +5Vdc A-phase pulse input (+) A-phase pulse input (-) B-phase pulse input (+) B-phase pulse input (-) Z-phase pulse input (+) Z-phase pulse input (-) A-phase pulse monitor output B-phase pulse monitor output Z-phase pulse monitor output • Shielded twisted-pair wires must be used for signal lines. • Do not use the PG-X2's power supply for anything other than the pulse generator (encoder). Using it for another purpose can cause malfunctions due to noise. • The length of the pulse generator's wiring must not be more than 100 meters. • The direction of rotation of the PG can be set in parameter F1-05 (PG Rotation). The factory preset is for motor forward rotation, A-phase advancement. Fig 2.22 PG-X2 Wiring Electrical Installation 2 - 37 PG-W2 The terminal specifications for the PG-W2 are given in Table 2.22. Table 2.22 PG-W2 Terminal Specifications Terminal No. Contents 1 Specifications 12Vdc (±5%), 200mA max. Power supply for Pulse Generator 2 0Vdc (GND for power supply) 3 A1-phase input terminals 4 5 B1-phase input terminals 6 J2 Pulse generator 1 input Line driver input (RS-422 level input) 7 Z1-phase input terminals 8 9 Shield - 10 A2-phase input terminals 11 12 B2-phase input terminals 13 Pulse generator 2 input Line driver input (RS-422 level input) 14 Z2-phase input terminals 15 16 Shield connection terminal - 17 A-phase output terminals 18 J1 19 B-phase output terminals 20 Pulse monitor output. Source depends on software parameter Line driver output (RS-422 level output) 21 Z-phase output terminals 22 23 Shield connection terminal - 24 0Vdc For pulse monitor terminals 17-22 Electrical Installation 2 - 38 Wiring the PG-W2 Wiring examples are provided in Fig 2.23 for the PG-W2. Branch Circuit Protection R/L1 U/T1 S/L2 V/T2 T/L3 W/T3 PG-1 M PG-W2 TP2 IP12 TP3 (+12V) 1 * 12V P 2 IG12 0V (0V) 3 Pulse A1 P 4 TP4 Pulse B1 5 P 6 TP5 Pulse Z1 7 P 8 PG-2 ** 9 TP6 (E) 10 Pulse A2 P 11 Drive TP7 12 Pulse B2 P 13 TP8 14 Pulse Z2 P 15 (E) 12V 16 0V 4CN 3 4CN 3 18 12V Pulse A 19 Pulse Out 1 20 3 Pulse B 21 Pulse Out 2 22 Pulse Monitor Outputs Pulse Z 23 12 (E) TP1 (E) Pulse A Pulse B Notes: * Power supply for PG-1 (from PG-W2). ** PG-2 requires external power supply. 24 IG5 +- P 17 (0V) Ground wire • Shielded twisted-pair wires must be used for signal lines. • Do not use the PG-W2's power supply for anything other than the pulse generator (encoder). Using it for another purpose can cause malfunctions due to noise. • The length of the pulse generator's wiring must not be more than 100 meters. • Do not use PG-W2 to supply both PG units. Fig 2.23 PG-W2 Wiring Electrical Installation 2 - 39 Wiring Terminal Blocks Wire Sizes (Same for All Models) Terminal wire sizes are shown in Table 2.23. Table 2.23 Wire Sizes Terminal Pulse generator power supply Pulse input terminal Pulse monitor output terminal Shield connection terminal Terminal Screws Wire Thickness AWG (mm2) - Stranded wire: 24 to 17 (0.2 to 1.0) Single wire: 24 to 17 (0.2 to 1.0) M3.5 20 to 16 (0.5 to 1.3) Wire Type • Shielded, twisted-pair wire • Shielded, polyethylene-covered, vinyl sheath cable • Belden 9504, Hitachi KPEV-S, or equivalent Wiring Method and Precautions Observe the following precautions when wiring. • Separate the control signal lines for the PG (Encoder) Feedback Board from main circuit lines and power lines. • Connect the shield when connecting a PG (Encoder). The shield must be connected to prevent operational errors caused by noise. Also, do not use any lines that are more than 100m long. Refer to Fig 2.12 for details on connecting the shield. • Do not solder the ends of wires. Doing so may cause contact faults. • When straight solderless terminals are not used, strip the wires to a length of approximately 5.5mm. • Use shielded, twisted-pair wires for pulse inputs and pulse output monitor wires, and connect the shield to the shield connection terminal. Electrical Installation 2 - 40 Selecting the Number of PG (Encoder) Pulses The setting for the number of PG pulses depends on the model of PG Speed Control Board being used. Set the correct number for your model. PG-A2/PG-B2 The maximum response frequency is 32,767Hz. Use a PG that outputs a maximum frequency of approximately 20kHz for the rotational speed of the motor. fPG (Hz) = Motor speed at maximum frequency output (RPM) × PG rating (PPR) 60 Some examples of PG output frequency (number of pulses) for the maximum frequency output are shown in Table 2.24. Table 2.24 PG Pulse Selection Examples Motor's Maximum Speed (RPM) PG Rating (PPR) PG Output Frequency (Hz) 1800 600 18,000 1500 800 20,000 1200 1000 20,000 900 1200 18,000 A separate power supply is required if the PG power supply capacity is greater than 200mA. (If momentary power loss must be handled, use a backup capacitor or other method). See Fig 2.24. PG power supply AC 0Vdc PG TA1 1 2 3 4 5 Capacitor for momentary power loss 0Vdc _ +12Vdc +12Vdc + 0Vdc + + _ _ + + _ _ 6 Signals TA3 Fig 2.24 PG-B2 Connection Example For External +12Vdc PG Power Supply Electrical Installation 2 - 41 PG PG-D2/PG-X2/PG-W2 The maximum response frequency is 300kHz. Use the following equation to computer the output frequency of the PG (fPG). fPG (Hz) = Motor speed at maximum frequency output (RPM) × PG rating (PPR) 60 A separate power supply is required if the PG power supply capacity is greater than 200mA. (If momentary power loss must be handled, use a backup capacitor or other method). See Fig 2.25. PG power supply PG-X2 AC 0Vdc TA1 IP12 1 IG Capacitor for momentary power loss _ +12Vdc +12Vdc + 2 IP5 3 0Vdc + A(+) 4 _ A(-) 5 + B(+) 6 _ B(-) 7 Z(+) 8 Z(-) 9 IG 10 TA3 Fig 2.25 PG-X2 Connection Example For External +12V PG Power Supply Electrical Installation 2 - 42 PG Chapter 3 Digital Operator This chapter describes the displays and functions of the Digital Operator. Digital Operator Display .................................................... 3-2 Digital Operator Keys ........................................................ 3-3 Drive Mode Indicators ....................................................... 3-4 Drive Main Menus ............................................................. 3-6 Quick Setting Menu (-QUICK-)........................................ 3-11 Programming Menu (-ADV-)............................................ 3-12 Example of Changing a Parameter ................................. 3-15 Digital Operator 3 - 1 Digital Operator Display The Digital Operator is used for programming, operating, monitoring, and copying the Drive’s parameters. To copy parameters, F7 Drives must have the same software version, model, and control method. The various items included on the Digital Operator are described below. Drive Mode Indicators See Table 3.2 Menu Display -DRIVE- Ready Display Rdy Frequency Ref U1-01= Drive can operate when a Drive command is input 60.00Hz ----------------------------- U1-02= U1-03= 60.00Hz 10.05A Data Display Displays monitor data, parameter data and settings 1 line x 13 characters 3 lines x 16 characters Key Descriptions See Table 3.1 RUN & STOP Indicators DATA DISPLAY EXAMPLE See Tables 3.5 and 3.6 -QUICK- Control Method -------------------------------- A1-02= 3 *3* Currently Programmed Value Flux Vector Factory Default Setting “2” Present Selection (User adjusts) Fig 3.1 Digital Operator Component Names and Functions Digital Operator 3 - 2 Digital Operator Keys The names and functions of the Digital Operator Keys are described in Table 3.1. Table 3.1 Digital Operator Keys Key Name Function LOCAL / REMOTE • Switches between operation via the Digital Operator (LOCAL) and the settings in parameter b1-01 (Frequency Reference Selection) and b1-02 (Run Command Selection) (REMOTE). • This key can be enabled or disabled by the setting in parameter o2-01. • The Drive must be in a stopped condition before it can be transferred to “LOCAL” or “REMOTE” mode. • Scrolls through the five main menus: MENU • Operation (-DRIVE-), Quick Setting (-QUICK-), Programming (-ADV-), Modified Constants (-VERIFY-), and Auto-Tuning (-A.TUNE-). ESCAPE JOG FWD / REV INCREASE DECREASE • Returns to the previous display, before the DATA/ENTER key was pressed. • Enables jog operation when the Drive is being operated from the Digital Operator (LOCAL). • Selects the rotation direction of the motor when the Drive is being operated from the Digital Operator (LOCAL). • Increases parameter numbers and set values. • Used to move to the next item or data value. • Decreases parameter numbers and set values. • Used to move to the previous item or data value. • Selects the digit to be changed. The selected digit will blink. SHIFT / RESET • Also resets the Drive when a fault has occurred. The run command must be removed before the reset command will be accepted. DATA / ENTER RUN • Enter menus and parameters as well as to set values. • Starts Drive operation when the Drive is being controlled by the Digital Operator (LOCAL). • Stops Drive operation. STOP Key • This key can be enabled or disabled when operating from the external terminal or communications by setting user parameter o2-02. Digital Operator 3 - 3 Drive Mode Indicators The definition of the Drive mode indicators are shown in Table 3.2. Table 3.2 Drive Mode Indicators Indicator Definition FWD Lit when a forward run command is input. REV Lit when a reverse run command is input. REMOTE SEQ See Table 3.3. REMOTE REF See Table 3.4. ALARM Lit when a fault has occurred. Flashes when an Alarm has occurred. REMOTE Sequence (SEQ) Indicator The status of the “REMOTE” Sequence (SEQ) indicator is shown in Table 3.3. This indicator is always “Off” when the Drive is in the “LOCAL” mode. When the Drive is in the “REMOTE” mode, the SEQ indicator status is dependent on the setting of parameter b1-02 (Run Command Selection). See Table 3.3. Table 3.3 REMOTE Sequence (SEQ) Indicator Indicator Status Condition On Parameter b1-02 (Run Command Selection) is set to terminal strip, communications, or an option board as indicated below: b1-02=1 (Terminals) =2 (Communications) =3 (Option PCB) Off Parameter b1-02 (Run Command Selection) is set to Digital Operator as indicated below: b1-02=0 (Operator) Digital Operator 3 - 4 REMOTE Reference (REF) Indicator The status of the “REMOTE” Reference (REF) indicator is shown in Table 3.4. This indicator is always “Off” when the Drive is in the “LOCAL” mode. When the Drive is in the “REMOTE” mode, the REF indicator status is dependent on the setting of parameter b1-01 (Frequency Reference Selection). See Table 3.4. Table 3.4 REMOTE Reference (REF) Indicator Indicator Status Condition On Parameter b1-01 (Frequency Reference Selection) is set to terminal strip, communications, option board, or pulse train as indicated below: b1-01=1 (Terminals) =2 (Communications) =3 (Option PCB) =4 (Pulse Train) Off Parameter b1-01 (Frequency Reference Selection) is set to digital operator as indicated below: b1-01=0 (Operator) Run Indicator The status of the “RUN” indicator is shown in Table 3.5 when the Drive is in either the “LOCAL” or “REMOTE” mode. Table 3.5 RUN Indicator Indicator Status Condition On Drive is running. Blinking Drive is decelerating to a stop. Off Drive is stopped. Stop Indicator The status of the “STOP” indicator is shown in Table 3.6 when the Drive is in either the “LOCAL” or “REMOTE” mode. Table 3.6 STOP Indicator Indicator Status On Blinking Off Condition Drive is decelerating to a stop or stopped. Drive is in a run condition but the frequency reference is less than the minimum output frequency E1-09, or the Drive is running in “REMOTE” mode and the “STOP” key on has been pressed. Drive is running. Digital Operator 3 - 5 Drive Main Menus The Drive’s parameters and monitoring functions are organized into groups called menus that make it easier to read and set parameters. The Drive is equipped with five menus. The five menus and their primary functions are shown in Table 3.7. Table 3.7 Drive Main Menus Main Menu Operation - DRIVE - Primary Functions The Drive can run in this menu. Use this menu for monitoring values such as frequency reference or output current, displaying fault history or displaying the fault traces. Quick Setting - QUICK - The Drive can be programmed in this menu. Use this menu to set/read the most commonly used parameters. Programming - ADV - The Drive can be programmed in this menu or parameters can be copied into the Digital Operator. Use this menu to set/read every parameter. Modified Constants - VERIFY Auto-Tuning - A.TUNE - The Drive can be programmed in this menu. Use this menu to set/read the parameters that have been modified from their factory default settings. The Drive can be programmed in this menu. Use this menu to Auto-Tune the Drive in order to optimize motor control. The motor parameters are calculated and set automatically after successfully completing Auto-Tuning. Digital Operator 3 - 6 Main Menu Structure The menu selection display will appear when the MENU key is pressed from a monitor or setting display. While viewing the menu selection display, press the MENU key repeatedly to scroll between the menu selections. Press the DATA/ENTER key to enter the desired menu selection. MENU -DRIVE** Main Menu ** -------------Operation MENU -DRIVE-QUICK** Main Menu ** -------------Quick Setting MENU -DRIVE-ADV** Main Menu ** -------------Programming MENU -DRIVE-VERIFY** Main Menu ** -------------Modified Consts MENU -DRIVE-A.TUNE** Main Menu ** -------------Auto-Tuning MENU Fig 3.2 Main Menu Structure Digital Operator 3 - 7 Operation Menu (-DRIVE-) This menu is used for setting the frequency reference (Local Mode) or monitoring values such as output frequency and output current. It is also used for displaying the fault history and the fault traces. The Drive must be in this menu in order to run. See parameter b1-08 (Run Command Selection During Program). U1 Monitor List Follow the key operations below (Fig 3.3) to access the Operation Menu: -DRIVE- x1 -DRIVERdy Frequency Ref U1-01= 0.00Hz ** Main Menu ** -------------Operation -------------------- U1-02= U1-03= 0.00Hz 0.00A Fig 3.3 U1 Monitor List Access Procedure Use and keys to scroll through the U1 “Monitor” parameter list. See Appendix A for functional description. Table 3.8 U1 Monitor List Monitors U1-01 Frequency Reference U1-21 ASR Input U1-02 Output Frequency U1-22 ASR Output U1-03 Output Current U1-24 PI Feedback Value U1-04 Control Method U1-25 DI-16 H2 Input Status U1-05 Motor Speed U1-26 Output Voltage Reference (Vq) U1-06 Output Voltage U1-27 Output Voltage Reference (Vd) U1-07 DC Bus Voltage U1-28 CPU Number U1-08 Output Power U1-29 kWh (Lower 4 digits) U1-09 Torque Reference U1-30 MWh (Upper 5 digits) U1-10 Input Terminal Status U1-32 ACR(q) Output U1-11 Output Terminal Status U1-33 ACR(d) Output U1-12 Drive Operation Status U1-34 OPE Detected U1-13 Cumulative Operation Time U1-35 Zero Servo Pulse Count U1-14 Software Number U1-36 PID Input U1-15 Terminal A1 Input Voltage U1-37 PID Output U1-16 Terminal A2 Input Voltage U1-38 PID Setpoint U1-17 Terminal A3 Input Voltage U1-39 Modbus Error Code U1-18 Motor Secondary Current (Iq) U1-40 Cooling Fan Elapsed Time U1-19 Motor Excitation Current (Id) U1-44 ASR Output with or without Filter U1-20 Output Frequency after Soft-start U1-45 Feed Forward Control Output Note: Some monitors are not available for all Control Modes (A1-02). Digital Operator 3 - 8 U2 Fault Trace List After viewing the “Monitor” parameter list, follow the key operations below (Fig 3.4) to access the “Fault Trace” parameter list. -DRIVERdy Monitor U1-01= 0.00Hz -DRIVERdy Fault Trace U2-01= None -DRIVERdy Current Fault U2-01= None -------------------- -------------------- -------------------- U1-02= U1-03= 0.00Hz 0.00A U2-02= U2-03= None 0.00Hz Fig 3.4 U2 Fault Trace List Access Procedure Use and keys to scroll through the U2 “Fault Trace” parameter list. Table 3.9 U2 Fault Trace List Fault Trace Parameters U2-01 Current Fault U2-02 Previous Fault U2-03 Frequency Reference at Fault* U2-04 Output Frequency at Fault* U2-05 Output Current at Fault* U2-06 Motor Speed at Fault* U2-07 Output Voltage at Fault* U2-08 DC Bus Voltage at Fault* U2-09 Output Power at Fault* U2-10 Torque Reference at Fault U2-11 Input Terminal Status at Fault* U2-12 Output Terminal Status at Fault* U2-13 Drive Operation Status at Fault* U2-14 Cumulative Operation Time at Fault* * Represents fault condition prior to current fault state. Note: Fault trace is not executed at CPF00, CPF01, CPF03, UV1, and UV2. Digital Operator 3 - 9 U2-02= U2-03= None 0.00Hz U3 Fault History List After viewing the “Fault Trace” parameter list, follow the key operations below (Fig 3.5) to access the “Fault History” parameter list. -DRIVERdy Fault Trace U2-01= None -DRIVERdy Fault History U3-01= None -DRIVERdy Last Fault U3-01= None -------------------- -------------------- -------------------- U2-02= U2-03= None 0.00A U3-02= U3-03= None None Fig 3.5 U3 Fault History Access Procedure Use and keys to scroll through the U3 “Fault History” parameter list. Table 3.10 Fault History List Fault History Parameters U3-01 Last Fault U3-02 Fault Message 2 U3-03 Fault Message 3 U3-04 Fault Message 4 U3-05 Elapsed Time 1 U3-06 Elapsed Time 2 U3-07 Elapsed Time 3 U3-08 Elapsed Time 4 U3-09 Fault Message 5 U3-10 Fault Message 6 U3-11 Fault Message 7 U3-12 Fault Message 8 U3-13 Fault Message 9 U3-14 Fault Message 10 U3-15 Elapsed Time 5 U3-16 Elapsed Time 6 U3-17 Elapsed Time 7 U3-18 Elapsed Time 8 U3-19 Elapsed Time 9 U3-20 Elapsed Time 10 Note: Fault trace is not executed at CPF00, CPF01, CPF03, UV1, and UV2. Digital Operator 3 - 10 U3-02= U3-03= None None Quick Setting Menu (-QUICK-) This menu is used to set/read the most commonly used parameters in the Drive. Follow the key operations in Fig 3.6 to access the Quick Setting Menu: -QUICK- x2 -QUICKReference Source ** Main Menu ** -------------Quick Setting -------------------- B1-01= Fig 3.6 Quick Setting Parameter Access Procedure Use and 1 Terminals “1” keys to scroll through the “Quick Setting” parameter list. Table 3.11 Quick Setting Parameter List Parameter Number Parameter Name A1-02 b1-01 b1-02 b1-03 C1-01 C1-02 C6-02 d1-01 d1-02 d1-03 d1-04 d1-17 E1-01 E1-03 E1-04 E1-05 E1-06 E1-09 E1-13 E2-01 E2-04 E2-11 F1-01 F1-21<3021> F1-22 <3021> H4-02 H4-05 L1-01 L3-04 Control Method Selection Frequency Reference Selection Run Command Selection Stopping Method Selection Acceleration Time 1 Deceleration Time 1 Carrier Frequency Selection Frequency Reference 1 Frequency Reference 2 Frequency Reference 3 Frequency Reference 4 Jog Reference Input Voltage Setting V/F Pattern Selection Maximum Output Frequency Maximum Output Voltage Base Frequency Minimum Output Frequency Base Voltage Motor Rated Current Number of Motor Poles Motor Rated Output PG Pulses / Revolution PG Pulse / Revolution 2 PG Rotation Selection Terminal FM Gain Setting Terminal AM Gain Setting Motor Overload Protection Selection Stall Prevention Selection During Decel Note: Refer to Appendix A for control method dependent parameters. Digital Operator 3 - 11 *1* Programming Menu (-ADV-) This menu is used to set/read every parameter in the Drive. Follow the key operations below (Fig 3.7) to access the Programming Menu. -ADV- -ADVInitialization ** Main Menu ** -------------Programming x3 -------------------- A1-00= 0 Select Language Fig 3.7 Programming Menu Access Procedure Use , see Appendix A. , and keys to scroll through the “Programming” parameter group list. For complete parameter listing Table 3.12 Programming Parameter Group List Parameter Group Functions A1 A2 b1 b2 b3 b4 b5 b6 b7 b8 b9 C1 C2 C3 C4 C5 C6 d1 d2 d3 d4 d5 d6 E1 E2 E3 E4 F1 Initialization User Parameters Sequence DC Injection Braking Speed Search Delay Timers PID Control Reference Hold Droop control Energy Saving Zero Servo Accel/Decel S-Curve Accel/Decel Motor-Slip Compensation Torque Compensation ASR Tuning Carrier Frequency Preset Reference Reference Limits Jump Frequencies Sequence (MOP & Trim Control) Torque Control Field-Weakening V/F Pattern Motor Setup V/F Pattern 2 Motor Setup 2 PG Option Setup F2 F3 F4 F5 F6 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6 L7 L8 n1 n2 n3 n5 o1 o2 o3 T1 AI-14 Setup DI-08, 16 Setup AO-08, 12 Setup DO-02, 08 Setup Communications Option Setup Digital Inputs Digital Outputs Analog Inputs Analog Outputs Serial Communications Setup Pulse I/O Setup Motor Overload Power Loss Ridethru Stall Prevention Reference Detection Fault Restart Torque Detection Torque Limit Hardware Protection Hunting Prevention AFR Tuning High Slip Braking Feed Forward Monitor Select Key Selections COPY Function Auto-Tuning - Note: Refer to Appendix A for control method dependent programming parameter groups. Digital Operator 3 - 12 Modified Constants Menu (-VERIFY-) This menu is used to set/read the parameters that have been modified from their original factory default settings. Follow the key operations below (Fig 3.8) to access the Modified Constants Parameter Menu. -VERIFY- x4 ** Main Menu ** -------------Modified Consts SeeNote Note 1 1 See Fig 3.8 Modified Constants Menu Access Procedure Note 1: If there are no parameters that have been modified from their original factory default settings, then the display will state “None Modified”. Otherwise, use and keys to scroll through the “Modified Constants” list. Auto-Tuning Menu (-A.TUNE-) This menu is used to Auto-Tune the Drive in order to calculate the required motor parameters to optimize motor performance. Ideally, perform Auto-Tuning with the motor uncoupled from the load. When the motor cannot be disconnected from the load, perform static or terminal resistance Auto-Tuning. To set motor parameters by hand calculation, contact your Yaskawa representative. Follow the key operations below (Fig 3.9) to access the Auto-Tuning Menu. x5 -A.TUNE- -A.TUNE-A.TUNE- ** Main Menu ** -------------Auto-Tuning ----------------------------- Tuning Mode Sel Mtr Rated Power -------------------- T1-01= T1-02= Fig 3.9 Auto-Tuning Menu Access Procedure Digital Operator 3 - 13 20.40kW *2* Term Resistance (0.00~650.00) “2” “0.40kW” Use and keys to scroll through the “Auto-Tuning” parameter list. Depending on the Control Method (A1-02) setting, only certain Auto-Tuning parameters will be accessible. See table below. Table 3.13 Auto-Tuning Parameter List Auto-Tuning Parameters Control Method V/F V/F w/PG OLV Flux Vector T1-01 Tuning Mode Selection O O O O T1-02 Motor Rated Power O O O O T1-03 Rated Voltage X X O O T1-04 Rated Current O O O O T1-05 Rated Frequency X X O O T1-06 Number of Poles X X O O T1-07 Rated Speed X X O O T1-08 PG Pulses/Rev X X X O O = Accessible After setting Auto-Tuning parameters according to motor nameplate specifications, press appears on the Digital Operator. -A.TUNE- Auto-Tuning so that the following screen Rdy ----------------------------- 0Hz/ 0.00A Tuning Ready ? Press RUN key Press the RUN key on the Digital Operator to start Auto-Tuning. The motor will automatically run. During this process the motor parameters will be automatically set in the Drive according to the measured values. Digital Operator 3 - 14 Example of Changing a Parameter Table 3.14 provides an example of how to change parameter “C1-02” (Deceleration Time 1) from 30 seconds to 40 seconds. Table 3.14 Changing a Parameter in the Programming Menu Step Number 1 Digital Operator Display -DRIVERdy Frequency Ref U1-01= 0.00Hz -------------------- U1-02= U1-03= Description The Drive is first powered up. 0.00Hz 0.00A -DRIVE- 2 ** Main Menu ** -------------Operation Press the MENU key to scroll to “Operation” menu. -QUICK- 3 ** Main Menu ** -------------Quick Setting Press the MENU key to scroll to “Quick Setting” menu. -ADV- 4 ** Main Menu ** -------------Programming Press the MENU key to scroll to “Programming” menu. -ADVInitialization 5 -------------------- A1-01= 0 Select Language Press the DATA/ENTER key to enter “Programming” menu. -ADVAccel/Decel 6 -------------------- C1-01= 1.0sec Accel Time 1 Press the INCREASE key until C1-01 (Accel/Decel) is displayed. -ADVAccel Time 1 7 -------------------- C1-01= 30.0sec Press the SHIFT/RESET key to move flashing digit to the right. (0.0~6000.0) “30.0sec” Digital Operator 3 - 15 Table 3.14 Changing a Parameter in the Programming Menu (continued) Step Number Digital Operator Display Description -ADVDecel Time 1 8 -------------------- C1-02= 30.0sec Press the INCREASE key to display C1-02 (Decel Time 1). (0.0~6000.0) “30.0sec” -ADVDecel Time 1 9 -------------------- C1-02= 0030.0sec Press the DATA/ENTER key to access setting display. (0.0~6000.0) “30.0sec” -ADVDecel Time 1 10 -------------------- C1-02= 0030.0sec Press the SHIFT/RESET key to move the flashing digit to the right. (0.0~6000.0) “30.0sec” -ADVDecel Time 1 11 -------------------- C1-02= 0030.0sec Press the SHIFT/RESET key to move the flashing digit to the right. (0.0~6000.0) “30.0sec” -ADVDecel Time 1 12 -------------------- C1-02= 0040.0sec Press the INCREASE key to increase the set data. (0.0~6000.0) “30.0sec” -ADV- 13 Entry Accepted Press the DATA/ENTER key to enter the set data. “Entry Accepted” is displayed for 1.0 sec after the data setting has been confirmed. -ADVDecel Time 1 14 -------------------- C1-02= 430.0sec The screen returns to the C1-02 display. (0.0~6000.0) “30.0sec” -DRIVE- 15 16 ** Main Menu ** -------------Operation -DRIVERdy Frequency Ref U1-01= 0.00Hz Press the MENU key to scroll to “Operation” menu. Press the DATA/ENTER key to enter “Operation” menu. -------------------- U1-02= U1-03= 0.00Hz 0.00A Digital Operator 3 - 16 Chapter 4 Start-Up This chapter describes the procedures to prepare the Drive for start-up and the procedures to conduct a Drive start-up. Drive Start-Up Preparation ................................................ 4-2 Drive Start-Up Procedures ................................................ 4-5 Start-Up 4 - 1 Drive Start-Up Preparation In order to provide the most reliable Drive available and to avoid any extra costs related to loss or reduction of warranty coverage, an authorized Yaskawa service representative should complete this start-up procedure. Please complete the following checklist and maintain it in a secure location as technical service personnel may request information from this checklist. Drive Start-Up Preparation Date: Start-Up Person: Company Name: _________________________________ Start-Up Location: _________________________________ Sales Order #: ___________________________________ Serial #: ________________________________________ Printed Name: ___________________________________ Drive Location: ___________________________________ Phone #: _______________________________________ Signature: ________________________________________ Owners Representative: Printed Name: ___________________________________ Phone #: _________________________________________ Company: ______________________________________ Signature: ________________________________________ Step 1. The Drive is thoroughly tested at the factory. The start-up person should verify that the Drive is free of shipping and installation damage. Shipping damage is not covered by the Yaskawa warranty. Claims must be filed with the shipping company as soon as possible for any potential recovery via insurance. 2. Review the F7 User Manual (TM.F7.01) shipped with the Drive. 3. Verify that the model number and voltage ratings in the purchase order match the nameplate data for each unit. 4. Location of the Drive is important to achieve proper performance and normal operating life. The unit should be installed in an area where it is protected from: Direct sunlight, rain or moisture Corrosive gases or liquids Vibration, airborne dust or metallic particles 5. Ensure the Drive is on a vertical surface with adequate space for air circulation (4.75” above and below, 1.2” on each side). Refer to Fig 1-8. 6. Verify that the proper branch circuit protection is installed in front of the Drive. Refer to Appendix E - Peripheral Devices for proper input fuse or circuit breaker sizing. Start-Up 4 - 2 7. Avoid running input and output wiring in the same conduit. 8. Avoid routing power wiring near equipment sensitive to electrical noise. 9. Never allow wire leads to touch metal surfaces. Short-circuit may result. 10. Never connect AC main power to output terminals U/T1, V/T2 and W/T3. 11. Never connect power factor correction capacitors or noise filters to the Drive output. 12. Use 600Vac vinyl-sheathed wire or equivalent. Wire size should be determined considering voltage drop of leads. Line voltage drop (V) = 3 x wire resistance (Ω/km) x wire length (m) x current (A) x 10-3 13. It is recommended that the motor lead length not exceed 164 feet (50 meters) and motor wiring be run in a separate conduit from the power wiring. If lead length must exceed this distance, reduce the carrier frequency (See Table 2.7) and consult Yaskawa toll free at 1-800-YASKAWA (927-5292) for other motor protection measures. 14. Signal and control leads must be separated from main circuit leads (R/L1, S/L2, T/L3, U/T1, V/T2, W/T3). 15. Determine proper wire size for power and motor leads. Refer to Tables 2.1 and 2.2 for details. 16. Review proper ground connections for the Drive. Refer to Chapter 2 – Electrical Installation for details. The Drive must be solidly grounded using the main circuit ground terminal. Ground resistance should be less than 100Ω for a 208-240Vac Drive. Ground resistance should be less than 10Ω for a 480Vac Drive. Select wire size suitable for the size of terminal screw. Make the length as short as possible. Never ground the Drive in common with welding machines, other motors, or other large-current electrical equipment. Where several Drives are used, ground each Drive directly or daisy-chain to the ground pole(s). DO NOT FORM A LOOP WITH THE GROUND LEADS. See Fig 2.4. 17. Review terminal functions of signal and control circuits. Refer to Table 2.11. 18. Verify if any customer safety devices are required (e.g. firestat, freezestat, high static pressure). 19. Record the following motor nameplate information: Motor Rated Power (KW): _________Voltage: _______________Full Load Amps: ________________ Rated Frequency:________________ Number of Poles: ________Rated Speed (RPM): _____________ 20. Verify that the commercial power supply is within the rated Drive input voltage: Power Supply: ____________________VAC Drive Input Voltage: _____________________VAC 21. Verify that the leads in the 3-Phase electric motor conduit box are configured for the proper voltage. 22. Ensure Motor Rated Current is less than or equal to Drive Output Amps. If multiple motors are being used, make sure that the Motor Rated Current sum is less than or equal to Drive Output Amp rating. Please note that if multiple motors are being operated from one Drive, each motor must have its own overload and short circuit protection. 23. Wire all necessary input power leads to the Drive. DO NOT CONNECT MOTOR TO DRIVE YET. 24. Wire all necessary ground wires to the Drive. 25. Wire all necessary control wires to the Drive. 26. Ensure that the power leads are connected to the R/L1, S/L2 and T/L3 terminals in the Drive. Start-Up 4 - 3 27. Tighten all of the three-phase power and ground connections. Please check that all control and signal terminations are tight. 28. For Drive models F7U4075 thru F7U4300, set the power supply voltage jumper. Insert the jumper into the voltage connector nearest to the actual power supply voltage. The jumper is factory-set to 460Vac when shipped. Be sure the power is off and the CHARGE indicator is gone out before changing the jumper setting. Power tab 200V class power supply Jumper (factory-set position) 400V class power supply Power supply input terminals CHARGE indicator Figure 4.1 Power Supply Voltage Jumper 29. Inspect the control circuit connections (including the shield) and determine if a motor “safety circuit” is connected. If normally closed, these contacts may be wired in series with the RUN command contacts, which are between terminals S1 and SN of the Drive. No special programming is required. Refer to Chapter 2 – Electrical Installation (Fig 2.10). Alternately, these contacts could be wired between terminals S3 and SN as External Fault Inputs, and may be either normally closed or normally open contacts. 30. Inspect any option cards for proper installation and wiring. Refer to Chapter 2 - Option Cards. 31. If Braking Resistors and/or Braking Transistor Units are used, check the terminal connections. Refer to Chapter 2 Braking Resistors. 32. If a contactor is used between the Drive and motor, wire the contactor so that the Drive controls the pull-in and dropout of the contactor. Use the “Run” multi-function output and necessary auxiliary circuitry to energize the contactor coil. Consult the factory for wiring details. 33. Record any other connections to the Drive using the blank terminal connection drawing in Chapter 2 – Electrical Installation (Fig 2.13) to determine if special programming is required for the following: (refer to Appendix A). Multi-function Inputs, Outputs, Digital Inputs, and Analog Outputs Serial Communications THIS COMPLETES THE DRIVE START-UP PREPARATION. Start-Up 4 - 4 Drive Start-Up Procedures 1. Confirm that all three phases are present and that the input voltage is correct for the Drive being set up. Measure the voltage on the line side of the Drive’s Molded Case Circuit Breaker/disconnect and record below. Table 4.1 Input Voltage Check Measurement Location Voltage (Vac) L1 – L2 L2 – L3 L1 – L3 2. If the voltage level is within the Drive’s specification, APPLY POWER to energize the Drive. The STOP, AUTO SEQ and AUTO REF indicators should be lit on the keypad. 3. REMOVE POWER from the Drive. Wait for the Red CHARGE LED (near the power terminals) to go out. 4. Connect the motor leads to the Drive at terminals U/T1, V/T2 and W/T3. 5. APPLY POWER to the Drive. 6. Determine the proper control method for the application: V/F Control, V/F with PG Control, Open Loop Vector, or Flux Vector Control. 7. If the selected control method requires a PG encoder on the motor (V/F with PG Control and Flux Vector Control), verify that the proper PG card is installed in the Drive and that all encoder wiring is correct. Check the line driver type (8830, 88C30), output levels, quadrature (A+, A-, B+, B-, etc.), and encoder PPR (pulses per revolution). Refer to Chapter 2 - Electrical Installation for details. 8. Proceed to the correct Control Method Start-Up Procedure: Table 4.2 Control Method Start-Up Procedure Control Method V/F Section V/F Start-Up V/F w/ PG Feedback V/F w/ PG Start-Up Open Loop Vector Open Loop Vector Start-Up Flux Vector Flux Vector Start-Up Start-Up 4 - 5 V/F Start-Up 9. Apply input power to the Drive. 10. Set the control method of the Drive to V/F Control by pressing the MENU key twice for the Quick Setting menu. Press the ENTER key to display A1-02 “Control Method”. Use the UP and DOWN keys and the DATA/ENTER key to set this parameter to “0: V/F Control”. Ensure the DATA/ENTER key is pressed to enter the selection in the Drive. “Entry Accepted” will briefly appear. 11. Set the Drive input voltage measured in Step 1. In the Quick Setting menu, go to parameter E1-01 “Input Voltage”. This parameter sets the nominal input voltage the Drive will receive. Table 4.3 Input Voltage Setting Parameter No. Parameter Name Digital Operator Display E1-01 Input Voltage Setting Input Voltage Setting Range Factory Setting 155.0 to 255.0 (208-240Vac) 240.0 (208-240Vac) 310.0 to 510.0 (480Vac) 480.0 (480Vac) Menu Location Quick Setting or Programming 12. Select an appropriate V/F pattern per the application. Go to parameter E1-03 “V/F Selection” and set this parameter per the application. A standard V/F pattern for a 60Hz motor is “1: 60Hz Saturation”. 13. Set the Drive to Local control. Press the MENU key once to display the Operation menu. Then, press DATA/ ENTER to display “Frequency Reference”. Press the LOCAL/REMOTE key once. This puts the Drive in the Local Mode, allowing run/stop and speed commands by the Digital Operator. The AUTO SEQ and AUTO REF indicators turn off, and the FWD light turns on. WARNING THE NEXT KEY-PRESS WILL CAUSE THE MOTOR TO ROTATE. TAKE APPROPRIATE PRECAUTIONS. 14. Check the motor rotation. Press and hold the JOG key to check motor rotation. The RUN light turns on and the STOP light is off. “Frequency Ref” (U1-01) now displays 6.00Hz on the Digital Operator. The frequency reference for this operation comes from parameter d1-17 “Jog Reference” with factory default setting of 6.00Hz. The motor should ramp up to speed. If the motor rotation is incorrect, swap any two motor leads (U/T1, V/T2, W/T3) on the Drive terminal, and repeat the motor rotation check. 15. Proceed to the Auto-Tuning section. Start-Up 4 - 6 V/F w/ PG Start-Up 1-8. See Drive Start-Up Procedures on Page 4-5. 9. Apply input power to the Drive. 10. Set the control method of the Drive to V/F w/ PG Feedback Control by pressing the MENU key twice for the Quick Setting menu. Press the ENTER key to display A1-02 “Control Method”. Use the UP and DOWN keys and the DATA/ENTER key to set this parameter to “1: V/F w/PG Fdbk”. Ensure the DATA/ENTER key is pressed to enter the selection in the Drive. “Entry Accepted” will briefly appear. 11. Set the Drive input voltage measured in Step 1. In the Quick Setting menu, go to parameter E1-01“Input Voltage”. This parameter sets the nominal input voltage the Drive will receive. Table 4.4 Input Voltage Setting Parameter No. E1-01 Parameter Name Digital Operator Display Input Voltage Setting Input Voltage Setting Range Factory Setting 155.0 to 255.0 (208-240Vac) 240.0 (208-240Vac) 310.0 to 510.0 (480Vac) 480.0 (480Vac) Menu Location Quick Setting or Programming 12. Select an appropriate V/F pattern per the application. Press the UP key once to display parameter E1-03 “V/F Selection”. To set this parameter press the DATA/ENTER key once. Use the UP and DOWN keys and the DATA/ENTER key to set this parameter per the application. A standard V/F pattern for a 60Hz motor is “1: 60Hz Saturation”. 13. Set the PG Pulses/Rev of the PG (Encoder) to the correct value. In the Quick Setting menu, go to parameter F1-01 “PG Pulses/Rev”. Use the UP, DOWN, and RESET keys and the DATA/ENTER key to set the encoder PPR. 14. Display motor speed monitor U1-05 “Motor Speed” in the Operation menu. 15. Rotate the motor shaft by hand in the forward direction for the machine. A low positive speed should be displayed (PG-B2, PG-X2, PG-W2). As the shaft is turned in reverse, a low negative speed should be displayed. If the speed doesn’t change when the motor shaft is rotated, check the encoder wiring and connections. If the polarity is wrong, swap A+ and A- wires (terminals 4 and 5 on the PG-X2). 16. Set the Drive to Local control. Press the MENU key once to display the Operation menu. Then, press DATA/ ENTER to display “Frequency Reference”. Press the LOCAL/REMOTE key once. This puts the Drive in the Local Mode, allowing run/stop and speed commands by the Digital Operator. The AUTO SEQ and AUTO REF indicators turn off, and the FWD light turns on. 17. Display monitor U1-01 “Frequency Ref” in the Operation menu. WARNING THE NEXT KEY-PRESS WILL CAUSE THE MOTOR TO ROTATE. TAKE APPROPRIATE PRECAUTIONS. Start-Up 4 - 7 18. Check the motor rotation. Press and hold the JOG key to check motor rotation. The RUN light turns on and the STOP light is off. U1-01 “Frequency Ref” now displays 6.00Hz on the Digital Operator. The frequency reference for this operation comes from parameter d1-17 “Jog Reference” with factory default setting of 6.00Hz. The motor should ramp up to speed. If the motor rotation is incorrect, swap any two motor leads (U/T1, V/T2, W/T3) on the Drive terminal, and repeat the motor rotation check. The encoder phasing (polarity) may also need to be reversed. 19. Proceed to the Auto-Tuning section. Open Loop Vector Start-Up 1-8. See Drive Start-Up Procedures on Page 4-5. 9. Apply input power to the Drive. 10. Set the control method of the Drive to Open Loop Vector Control by pressing the MENU key twice for the Quick Setting menu. Press the ENTER key to display A1-02 “Control Method”. Use the UP and DOWN keys and the DATA/ENTER key to set this parameter to “2: Open Loop Vector”. Ensure the DATA/ENTER key is pressed to enter the selection in the Drive. “Entry Accepted” will briefly appear. 11. Set the Drive to Local control. Press the MENU key once to display the Operation menu. Then, press DATA/ ENTER to display “Frequency Reference”. Press the LOCAL/REMOTE key once. This puts the Drive in the Local Mode, allowing run/stop and speed commands by the Digital Operator. The AUTO SEQ and AUTO REF indicators turn off. The FWD light turns on. WARNING THE NEXT KEY-PRESS WILL CAUSE THE MOTOR TO ROTATE. TAKE APPROPRIATE PRECAUTIONS. 12. Check the motor rotation. Press and hold the JOG key to check motor rotation. The RUN light turns on and the STOP light is off. “Frequency Ref” (U1-01) now displays 6.00Hz on the Digital Operator. The frequency reference for this operation comes from parameter d1-17 “Jog Reference” with a factory default setting of 6.00Hz. The motor should ramp up to speed. If the motor rotation is incorrect, swap any two motor leads (U/T1, V/T2, W/T3) on the Drive terminal, and repeat the motor rotation check. 13. Proceed to the Auto-Tuning section. Start-Up 4 - 8 Flux Vector Start-Up 1-8. See Drive Start-Up Procedures on Page 4-5. 9. Apply input power to the Drive. 10. Set the control method of the Drive to Flux Vector Control by pressing the MENU key twice for the Quick Setting menu. Press the ENTER key to display A1-02 “Control Method”. Use the UP and DOWN keys and the DATA/ ENTER key to set this parameter to “3: Flux Vector”. Ensure the DATA/ENTER key is pressed to enter the selection in the Drive. “Entry Accepted” will briefly appear. 11. Set the PG Pulses/Rev of the PG (Encoder) to the correct value. In the Quick Setting menu, go to parameter F1-01 “PG Pulses/Rev”. Use the UP, DOWN, and RESET keys and the DATA/ENTER key to set the encoder PPR. 12. Display motor speed monitor U1-05 “Motor Speed” in the Operation menu. 13. Rotate the motor shaft by hand in the forward direction of the machine. A low positive speed should be displayed (PG-B2, PG-X2, PG-W2). As the shaft is turned in reverse, a low negative speed should be displayed. If the speed doesn’t change when the motor shaft is rotated, check the encoder wiring and connections. If the polarity is wrong, swap A+ and A- wires (terminals 4 and 5 on the PG-X2). 14. Set the Drive to Local control. Press the MENU key once to display the Operation menu. Then, press DATA/ ENTER to display “Frequency Reference”. Press the LOCAL/REMOTE key once. This puts the Drive in the Local Mode, allowing run/stop and speed commands by the Digital Operator. The AUTO SEQ and AUTO REF indicators turn off, and the FWD light turns on. 15. Display monitor U1-01 “Frequency Ref” in the Operation menu. WARNING THE NEXT KEY-PRESS WILL CAUSE THE MOTOR TO ROTATE. TAKE APPROPRIATE PRECAUTIONS. 16. Check the motor rotation. Press and hold the JOG key to check motor rotation. The RUN light turns on and the STOP light is off. U1-01 “Frequency Ref” displays 6.00Hz on the Digital Operator. The frequency reference for this operation comes from parameter d1-17 “Jog Reference” with a factory default setting of 6.00Hz. The motor should ramp up to speed. If the motor rotation is incorrect, swap any two motor leads (U/T1, V/T2, W/T3) on the Drive terminal, and repeat the motor rotation check. The encoder polarity may need to be reversed. 17. Proceed to the Auto-Tuning section. Start-Up 4 - 9 Auto-Tuning Auto-Tuning the motor is required for optimum performance. Use the following flow chart to determine which one of the three Auto-Tuning Mode Selections to use. START Open-loop Vector or Flux Vector NO Use "Tune - No Rotate" (T1-01 = 1) NO Motor is uncoupled from the load? V/F Control Method (A1-02 = 0 or 1)? YES V/F Control or V/F w/PG Fdbk YES Use "Standard Tuning" (T1-01 = 0) Use "Term Resistance" (T1-01 = 2) Figure 4.2 Auto-Tuning Selection Flow Chart Note: Performing Auto-Tuning energizes the motor so that identification of key motor characteristics can be determined. Output filters may affect the accurancy of the measured characteristics and/or result in drive damage. Therefore, it may be necesary to remove the filters completely prior to executing the following tuning procedure. Consult the factory with questions regarding filter compatibility. Standard Tuning Always use Standard Tuning (rotational) when operating in Open Loop Vector or Flux Vector (A1-02 = 2 or 3) and it is possible to run the motor uncoupled from the load. 1. Select the Auto-Tuning Menu. Then, select “Standard Tuning” in the “Tuning Mode Sel” parameter (T1-01 = 0). 2. Set the motor output power (T1-02), motor rated voltage (T1-03), motor rated current (T1-04), motor base frequency (T1-05), number of motor poles (T1-06), motor rated speed (T1-07) obtained from the motor nameplate information. If the Control Method is Flux Vector (A1-02 = 3), be sure to set the encoder pulses per revolution (PPR) (T1-08). After entering all of the motor parameters press the UP key to display “0Hz/ 0.00A Tuning Ready?”. WARNING THE NEXT KEY-PRESS WILL CAUSE THE MOTOR TO ROTATE. TAKE APPROPRIATE PRECAUTIONS. Start-Up 4 - 10 3. Confirm that the motor is uncoupled from the load and make sure it is safe to rotate the motor. Press the RUN key to start Auto-Tuning. The Drive will energize the motor without rotating it for approximately 1 minute. Then, the Drive will set the required motor parameters automatically while rotating the motor for approximately 1 minute. If the Auto-Tuning was successful, the operator keypad will display “Tune Successful”. 4. Proceed to the Quick Setting Parameters section. No Rotate Tuning Use No Rotate Tuning when operating in Open Loop Vector or Flux Vector control (A1-02 = 2 or 3) and it is impossible to uncouple the load from the motor. 1. Select the Auto-Tuning Menu. Then, select “Tune-No Rotate” in the “Tuning Mode Sel” parameter (T1-01 = 1). 2. Set the motor output power (T1-02), motor rated voltage (T1-03), motor rated current (T1-04), motor base frequency (T1-05), number of motor poles (T1-06), and motor rated speed (T1-07) obtained from the motor nameplate information. After entering all of the motor parameters press the UP key to display “0Hz/0.00A Tuning Ready?”. 3. Press the RUN key to start Auto-Tuning. The Drive will set the required motor parameters automatically while energizing the motor (without rotation) for approximately 1 minute. If the Auto-Tuning is successful, the operator keypad will display “Tune Successful”. 4. Proceed to the Quick Setting Parameters section. Terminal Resistance Tuning Terminal Resistance Tuning is the only Auto-Tuning method available when using V/F or V/F w/ Feedback control (A1-02 = 0 or 1). 1. Select the Auto-Tuning Menu. Then, select “Term Resistance” in the “Tuning Mode Sel” parameter (T1-01 = 2). 2. Set the motor output power (T1-02) and motor rated current (T1-04) obtained from the motor nameplate information. After entering all of the motor parameters press the UP key to display “0Hz/ 0.00A Tuning Ready?”. 3. Press the RUN key to start Auto-Tuning. The Drive will set the required motor parameter automatically while energizing the motor (without rotation) for approximately 30 seconds. If the Auto-Tuning is successful, the Digital Operator keypad will display “Tune Successful”. 4. Proceed to the Quick Setting Parameters section. Start-Up 4 - 11 Quick Setting Parameters The following Drive parameters located in the Quick Setting menu need to be set according to the application. Refer to Chapter 5 Basic Programming section for more details on each parameter. Note: Not all parameters are available for all Control Methods. See Control Method column. Control Method Setting Range Factory Setting V/F V/F w/ PG OLV FV Control Method Selection Control Method Selects the Control Method of the Drive. 0: V/F control without PG 1: V/F control with PG 2: Open Loop Vector 3: Flux Vector (Closed Loop Vector) 0 to 3 0 Q Q Q Q b1-01 Frequency Reference Selection Reference Source Selects the frequency reference input source. 0: Operator - Digital preset speed U1-01 or d1-01 to d1-17. 1: Terminals - Analog Input Terminal A1 (Terminal A2 sums together with terminal A1 when H3-09=0) 2: Serial Com - Modbus RS-422/485 terminals R+, R-, S+ and S3: Option PCB - Option board connected on 2CN 4: Pulse Input 0 to 4 1 Q Q Q Q b1-02 Run Command Selection Run Source Selects the run command input source. 0: Operator - RUN and STOP keys on Digital Operator 1: Terminals - Contact closure on terminals S1 or S2 2: Serial Com - Modbus RS-422/485 terminals R+, R-, S+ and S3: Option PCB - Option board connected on 2CN 0 to 3 1 Q Q Q Q Stopping Method Selection Stopping Method Selects the stopping method when the run command is removed. 0: Ramp to Stop 1: Coast to Stop 2: DC Injection to Stop 3: Coast with Timer (A new run command is ignored if input before the timer expires.) 0 to 3 0 Q Q Q Q Acceleration Time 1 Accel Time 1 Sets the time to accelerate from zero to maximum frequency (E1-04). 10.0sec Q Q Q Q Deceleration Time 1 Decel Time 1 Sets the time to decelerate from maximum frequency to zero (E1-04). 0.0 to 6000.0 Q Q Q Q Carrier Frequency Selection CarrierFreq Sel Selects the number of pulses per second of the output voltage waveform. Setting range determined by C6-01 setting. 0: Low noise 1: Fc = 2.0 kHz 2: Fc = 5.0 kHz 3: Fc = 8.0 kHz 4: Fc = 10.0 kHz 5: Fc = 12.5 kHz 6: Fc = 15.0 kHz F: Program (Determined by the settings of C6-03 thru C6-05) Varies by kVA Varies by kVA Q Q Q Q Frequency Reference 1 Reference 1 Setting units are affected by o1-03. 0.00Hz Q Q Q Q 0.00Hz Q Q Q Q 0.00Hz Q Q Q Q Parameter No. A1-02 b1-03 C1-01 C1-02 C6-02 d1-01 Parameter Name Description Digital Operator Display 0.00 to E1-04 Value d1-02 Frequency Reference 2 Reference 2 Frequency reference when multi-function input “Multi-step speed reference 1” is ON. Setting units are affected by o1-03. d1-03 Frequency Reference 3 Reference 3 Frequency reference when multi-function input “Multi-step speed reference 2” is ON. Setting units are affected by o1-03. d1-04 Frequency Reference 4 Reference 4 Frequency reference when multi-function input “Multi-step speed reference 1,2” is ON. Setting units are affected by o1-03. 0.00Hz Q Q Q Q d1-17 Jog Frequency Reference Jog Reference Frequency reference when: “Jog Frequency Reference”, “Forward Jog”, or “Reverse Jog” is selected via multi-function input terminals or JOG key is pressed on the operator keypad. Jog reference has priority over frequency reference 1 to 4. Setting units are affected by o1-03. 6.00Hz Q Q Q Q Denotes that parameter can be changed when the Drive is running. Start-Up 4 - 12 Control Method Parameter No. Parameter Name Setting Range Description Digital Operator Display Input Voltage Setting Input Voltage Set to the nominal voltage of the incoming line, sets maximum/ base voltage used by preset V/F patterns (E1-03 = 0 to E), adjusts the levels of Drive protective features (i.e. Overvoltage, braking resistor turn-on, stall prevention, etc.). 155 to 255.0 (240V) 310 to 510.0 (480V) E1-03 V/F Pattern Selection V/F Selection Set to the type of motor being used and the type of application. The Drive operates utilizing a set V/F pattern to determine the appropriate output voltage level for each commanded speed. There are 15 different preset V/F patterns to select from (E1-03 = 0 to E) with varying voltage profiles, base levels (base level = frequency at which maximum voltage is reached), and maximum frequencies. There are also settings for Custom V/F patterns that will use the settings of parameters E1-04 through E1-13. E1-03 = F selects a custom V/F pattern with an upper voltage limit and E1-03 = FF selects a custom V/F pattern without an upper voltage limit. 0: 50Hz 1: 60Hz 2: 60Hz (50Hz Base) 3: 72Hz (60Hz Base) 4: 50Hz VT1 5: 50Hz VT2 6: 60Hz VT1 7: 60Hz VT2 8: 50Hz HST1 9: 50Hz HST2 A: 60Hz HST1 B: 60Hz HST2 C: 90Hz (60Hz Base) D: 120Hz (60Hz Base) E: 180Hz (60Hz Base) F: Custom V/F FF:Custom w/o limit 0 to FF E1-04 Maximum Output Frequency Max Frequency E1-01 E1-05 Maximum Output Voltage Max Voltage These parameters are only applicable when V/F Pattern Selection is set to Custom (E1-03 = F or FF). To set V/F characteristics in a straight line, set the same values for E1-07 and E1-09. In this case, the setting for E1-08 will be disregarded. Always ensure that the four frequencies are set in the following manner: E1-04 ≥ E1-12 ≥ E1-06 > E1-07 ≥ E1-09 E2-04 is automatically set during Auto-Tuning. Output voltage (V) E1-06 Base Frequency Base Frequency E1-09 Minimum Output Frequency Min Frequency E1-13 Base Voltage Base Voltage E2-01 Motor Rated Current Motor Rated FLA E1-05 E1-12 E1-13 E1-08 Factory Setting V/F V/F w/ PG OLV FV Q Q Q Q F Q Q - - 60.0Hz Q Q Q Q Q Q Q Q 240V 480V HD: 40.0 to 300.0 ND2: 40.0 to 400.0 0 to 255.0 (240V) 0 to 510.0 (480V) 240V 480V 0.0 to 200.0 60.0Hz Q Q Q Q 0.0 to 200.0 1.5Hz Q Q Q A 0 to 255.0 (240V) 0 to 510.0 (480V) 0.0VAC A A Q Q Varies by kVA Varies by kVA Q Q Q Q 2 to 48 4 - Q - Q 0.00 to 650.00 Varies by kVA Q Q Q Q 0 to 60000 1024 - Q - Q E1-10 E2-04 E1-09 Number of Motor Poles Number of Poles E1-07 E1-06 E1-11 E1-04 Frequency (Hz) E2-11 Motor Rated Output Motor Rated Power Set to the motor rated power in KW. This value is automatically set during Auto-Tuning. F1-01 PG Parameter PG Pulse/Rev Sets the number of pulses per revolution of the encoder (pulse generator). This value is automatically set during Auto-Tuning. Denotes that parameter can be changed when the Drive is running. Start-Up 4 - 13 Control Method Parameter No. F1-21 <3021> Parameter Name Description Digital Operator Display Setting Range Factory Setting V/F V/F w/ PG OLV FV PG Constant 2 PG Pulse / Rev 2 Sets the number of pulses for the encoder (pulse generator) for each full rotation of Motor 2. 0 to 60000 1024 No Q No Q PG Rotation 2 PG Rotation Sel 2 Determines the direction of rotation for the encoder (PG) connected to Motor 2. 0: Phase A leads with Forward Run Command. (Phase B leads with Reverse Run Command.) 1: Phase B leads with Forward Run Command. (Phase A leads with Reverse Run Command.) 0, 1 0 No Q No Q H4-02 Terminal FM Gain Setting Terminal FM Gain Sets terminal FM output voltage (in percent of 10Vdc) when selected monitor is at 100% output. 0.0 to 1000.0 100.0% Q Q Q Q H4-05 Terminal AM Gain Setting Terminal AM Gain Sets terminal AM output voltage (in percent of 10Vdc) when selected monitor is at 100% output. 0.0 to 1000.0 50.0% Q Q Q Q Motor Overload Protection Selection MOL Fault Select Sets the motor thermal overload protection (OL1) based on the cooling capacity of the motor. 0: Disabled 1: Standard Fan Cooled (<10:1 motor) 2: Standard Blower Cooled (10:1 motor) 3: Vector Motor (1000:1 motor) 0 to 1 1 Q Q Q Q Stall Prevention Selection During Decel StallP Decel Sel When using a braking resistor, use setting “0”. Setting “3” is used in very specific applications. 0: Disabled - The Drive decelerates at the active deceleration rate. If the load is too large or the deceleration time is too short, an OV fault may occur. 1: General Purpose - The Drive decelerates at the active deceleration rate, but if the main circuit DC bus voltage reaches the stall prevention level (380/760 Vdc), deceleration will stop. Deceleration will continue once the DC bus level drops below the stall prevention level. 2: Intelligent - The active deceleration rate is ignored and the Drive decelerates as fast as possible w/o hitting OV fault level. Range: C1-02/10. 3: Stall Prevention w/ Braking Resistor 0 to 3 1 Q Q Q Q F1-22 <3021> L1-01 L3-04 Denotes that parameter can be changed when the Drive is running. Start-Up 4 - 14 Trial Run 1. Press the LOCAL/REMOTE key once. This puts the Drive in the Local Mode, allowing run/stop and speed commands by the Digital Operator. The AUTO SEQ and AUTO REF indicators turn off, and the FWD light turns on. 2. Run the Drive at different frequencies and record monitor values. With the Drive in Local Mode, press the ENTER key at Frequency Reference Monitor (U1-01). Use the UP, DOWN, and RESET keys to set the frequency reference. Then, press the DATA/ENTER key to accept the frequency reference entered. Run the Drive at the set frequency reference by pressing the RUN key. Use the UP and DOWN keys to view Output Current (U1-03), Output Voltage (U1-06), and DC Bus Voltage (U1-07) while running the Drive throughout its entire speed range. Record the following information at each speed: Frequency (Hz) Monitor U1-01 Output Current (A) Monitor U1-03 Output Voltage (Vac) Monitor U1-06 DC Bus Voltage (Vdc) Monitor U1-07 6.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.0 60.0 When this table is complete, press the STOP key. The Drive will stop and the FWD light remains on. This step provides benchmark data for the application from the initial start-up. 3. Press the MENU key once to display “Operation”. Press the DATA/ENTER key to display “Frequency Ref”. If using a remote speed command, press the LOCAL/REMOTE key so the REMOTE SEQ and REMOTE REF indicators are on. This puts the Drive in REMOTE mode. 4. If using an external speed command, determine whether the speed command is a 0-10Vdc or a 4-20mA signal. Connect the positive side of a 0-10Vdc signal to terminal A1. Connect the positive side of a 4-20mA signal to terminal A2. Connect the COMMON of the speed command to terminal AC. Note: Connect only one input. The factory default is 0-10Vdc. To change to 4-20mA, adjust parameter H3-08 to “2: 4 – 20mA” and ensure DIP Switch S1-2 (located on the terminal board) is in the ON position. Start-Up 4 - 15 5. Check the signal for proper polarity. Observe if the speed command can achieve the minimum and maximum speeds desired. If not, perform the following: For 0-10Vdc input (Terminal A1) 1. With no input, adjust Bias (H3-03 setting) until an output of “0.0Hz” is obtained. 2. With full-scale input, adjust Gain (H3-02 setting) until an output of “60.0Hz” (or other desired maximum frequency) is obtained. For 4-20mA input (Terminal A2) 1. With 4mA input, adjust Bias (H3-11 setting) until an output of “0.0Hz” is obtained. 2. With 20mA input, adjust Gain (H3-10 setting) until an output of “60.0Hz” (or other desired maximum frequency) is obtained. THIS COMPLETES THE DRIVE START-UP PROCEDURES. Start-Up 4 - 16 Chapter 5 Basic Programming This chapter describes basic programming for the Drive. Description of Parameter Tables....................................... 5-2 Control Method.................................................................. 5-2 Speed Command Source .................................................. 5-3 Run Command Source...................................................... 5-4 Stopping Method ............................................................... 5-5 Accel/Decel Time .............................................................. 5-8 Carrier Frequency ............................................................. 5-9 Preset Reference ............................................................ 5-11 Input Voltage Setting ....................................................... 5-12 V/F Pattern ...................................................................... 5-12 Motor Setup..................................................................... 5-20 PG Option........................................................................ 5-20 Analog Output Gain......................................................... 5-21 Motor Overload Fault....................................................... 5-22 Stall Prevention ............................................................... 5-23 Basic Programming 5 - 1 F7 Basic Programming Parameters Description of Parameter Tables This chapter details all of the parameters in the Quick Setting Menu (-QUICK-). Some parameters are not available for all Control Methods. See Appendix A for details. Setting range and factory default value of the parameter follows the control method table for each parameter. Control Method A1-02 Control Method Selection Setting Description 0 V/F Control (factory default) 1 V/F with PG Feedback 2 Open Loop Vector 3 Flux Vector The setting of parameter A1-02 determines which control method the Drive will use for operation. Select the control method best suited for the application: V/F Control is for general purpose and multiple motor applications. V/F with PG Feedback is for general purpose applications requiring closed loop speed control. Open Loop Vector is for applications requiring precise speed control, quick response, and higher torque at low speeds (150% torque below 1Hz). Flux Vector Control is for applications requiring very precise speed and torque control at a wide speed range including zero speed. It requires encoder feedback. Basic Programming 5 - 2 Speed Command Source b1-01 Reference Source Selection Setting Description 0 Operator - Monitor U1-01 or parameter d1-01 1 Terminals - Analog input terminal A1 (Terminal A2 sums together with terminal A1 when H3-09=0) (factory default) 2 Modbus Serial Communication - RS-422/485 terminals R+, R-, S+, and S- 3 Option Board - Option board connected on 2CN 4 Pulse Train Input - Terminal RP and AC In order to run the Drive and motor in REMOTE mode, the Drive must receive a run command and a speed command from an external source. Parameter b1-01 specifies from where the speed command will be accepted. To switch into the “REMOTE” mode press the LOCAL/REMOTE button on the Digital Operator while the Drive is stopped. IMPORTANT If the set speed command is less than the minimum output frequency (E1-09) with a run command input, the RUN indicator on the Digital Operator will turn on and the STOP indicator on the Digital Operator will blink. To have the Drive follow the speed command set by the Digital Operator: Set b1-01=0. The speed command can then be entered into the U1-01 monitor or in parameter d1-01. To have the Drive follow an analog speed command: Set b1-01 = 1 and connect a 0 to 10Vdc or -10 to +10Vdc signal to terminals A1 and AC. Be sure to set parameter H3-01 to the proper setting. Or, connect a 4 – 20mA signal to terminals A2 and AC. Make sure the S1-2 switch and corresponding parameter H3-08 is properly set up when using terminal A2 To have the Drive receive the speed command from Modbus serial communication: Set b1-01 = 2 and connect the RS-485/422 serial communications cable to terminals R+, R-, S+, and S- on the removable terminal block. Make sure the S1-1 switch and the Modbus H5 parameters are properly set. To use an option board to input the speed command: Set b1-01 = 3 and install a communications analog input, or digital input option board into the 2CN port on the Drive control board. Consult the manual supplied with the option board for instructions on integrating the Drive and communications option board. IMPORTANT If b1-01=3 but an option board is not installed in 2CN, an OPE05 Fault will be displayed on the digital operator and the Drive will not run. To use pulse train to input a speed command: Set b1-01 = 4 and connect the pulse train signal to terminals RP and AC. Make sure the H6 parameters are properly set. Basic Programming 5 - 3 Run Command Source b1-02 Run Source Selection Setting Description 0 Operator - RUN and STOP keys on Digital Operator 1 Terminals - Contact closure between terminal S1 and SN (factory default) 2 Modbus Serial Communication - RS-422/485 terminals R+, R-, S+, and S- 3 Option Board - Option board connected to 2CN In order to run the Drive and motor in REMOTE mode, the Drive must receive a run command and a speed command from an external source. Parameter b1-02 specifies from where the RUN command will be accepted. To issue a run command from the Digital Operator: Set b1-02=0 and use the RUN and STOP keys on the Digital Operator to start and stop the Drive. To issue the run command from the terminals: Set b1-02=1 and select between 2-wire and 3-wire operation according to the following: 2-Wire Control: The factory setting is for 2-wire operation. In the 2-wire configuration, a closure between S1 and SN will be interpreted as a Forward run command by the Drive. A closure between S2 and SN will be interpreted as a Reverse run command. If both S1 and S2 are closed, the Drive will alarm and the Digital Operator will flash an EF fault. The Drive will not run in this condition. S1 FWD Run/Stop S2 REV Run/Stop SN Fig 5.1 2-Wire Control 3-Wire Control: When any of the multi-function digital input parameters, H1-01 through H1-05, is set to 0, terminals S1 and S2 become Run and Stop, respectively. The multi-function digital input that was set to 0 will function as a Forward/Reverse input for the Drive. When the Forward/Reverse input is open the Drive will run in the Forward direction and when the input is closed, the Drive will run in the Reverse direction. In 3-wire operation, a momentary closure (> 50mS) between S1 and SN will cause the Drive to run provided that S2 and SN is held closed. The Drive will stop any time the S2-SN connection is broken. If the 3-wire configuration is implemented via a 3-wire Initialization (A1-03=3330), terminal S5 becomes the Forward/Reverse input. S1 S2 Run Command (Run on momentary “Close”) Stop Command (Stop on momentary “Open”) S5 FWD/REV Run Selection (FWD Run when “Open” Rev Run when “Closed”) SN Fig 5.2 3-Wire Control Basic Programming 5 - 4 To issue a run command via Modbus serial communication: Set b1-02=2 (Modbus communication) and connect the Modbus RS-485/422 serial communication cable to R+, R-, S+, and S- on the removable terminal block. Make sure the S1-1 switch and the Modbus H5 parameters are properly set. To issue the RUN command via an option card: Set b1-02=3 and install an option board into the 2CN port on the control board. Consult the manual supplied with the option board for instructions on integrating the Drive and communication option board. IMPORTANT If b1-01=3 but an option board is not installed in 2CN, an OPE05 operator programming error will be displayed on the Digital Operator and the Drive will not run. Stopping Method b1-03 Stopping Method Selection Setting 0 1 2 3 Description Ramp to Stop (factory default) Coast to Stop DC Injection to Stop Coast to Stop with Timer There are four methods of stopping the Drive when the RUN command is removed. 0: Ramp to stop: When the run command is removed, the Drive will decelerate the motor to minimum output frequency (E1-09) and then shut off. The rate of deceleration is determined by the active deceleration time. The factory default Decel Time is parameter C1-02. Basic Programming 5 - 5 When the output frequency has dropped below the DC Injection Start Frequency (b2-01) or the minimum output frequency (E1-09) (whichever is greater), deceleration will stop and DC current will be injected into the motor at the current level set in b2-02 for the time set in b2-04. ON Run Command OFF DC Injection Start Frequency (b2-01) 100 % DC Injection Brake Time when Stopping (b2-04) Output Frequency Deceleration Time (C1-02) DC Injection Braking 0% Fig 5.3 Deceleration to Stop The actual deceleration time can be determined by the following formula: Time to stop = IMPORTANT 1: Coast to stop: Output frequency at time of stop command x Active deceleration time Maximum frequency (E1 − 04) If S-Curve characteristics are set in the Drive programming, they will add to the total time to stop. When the run command is removed, the Drive will turn off its output transistors. The friction of the driven equipment will eventually overcome any residual inertia of the system and the motor will stop. ON Run Command OFF 100 % Output Frequency 0% Fig 5.4 Coast to Stop IMPORTANT After a stop is initiated, subsequent run commands will be ignored until the Minimum Baseblock Time (L2-03) has expired. Basic Programming 5 - 6 2: DC Injection to Stop: When the run command is removed, the Drive will Baseblock (turn off all output transistors) for the Minimum Baseblock Time (L2-03). Once the Minimum Baseblock Time has expired, the Drive will inject DC current into the motor windings to try and lock the motor shaft. The stopping time will be reduced as compared to Coast to Stop. The level of DC Injection current is set by parameter b2-02. The DC Injection brake time is determined by the set value in b2-04 and the output frequency at the time the run command is removed. DC Injection Brake Time = (b2 - 04) × 10 × Output Frequency Maximum Frequency (E1 - 04) ON Run Command b2-04 x 10 OFF DC Injection Brake Time 100 % b2-04 Output Frequency 100% (Maximum Output Frequency) Output Frequency at Stop Command Input 10% DC Injection Braking 0% Minimum Baseblock Time (L2-03) DC Injection Braking Time Fig 5.5 DC Injection Braking to Stop IMPORTANT If an overcurrent (OC) fault occurs during DC Injection Braking to Stop, lengthen the Minimum Baseblock Time (L2-03) until the fault no longer occurs. 3: Coast to Stop with Timer: When the run command is removed, the Drive will turn off its output transistors and the motor will coast to a stop. If a run command is input before the timer expires, the Drive will not run and the run command will be ignored. The timer value is determined by the active deceleration time and the output frequency when the run command is removed. ON Run Command OFF Deceleration Time Timer Value 100 % Minimum Baseblock Time (L2-03) Output Frequency Minimum Output Frequency 0% Timer Value Fig 5.6 Coast to Stop with Timer Basic Programming 5 - 7 100% (Maximum Output Frequency) Output Frequency at Stop Command Input Accel/Decel Time C1-01 Acceleration Time 1 C1-02 Deceleration Time 1 Setting Range: 0.0 to 6000.0 Factory Default: 10.0sec C1-01 (Acceleration Time 1) sets the time to accelerate from zero to maximum output frequency (E1-04). C1-02 (Deceleration Time 1) sets the time to decelerate from maximum output frequency to zero. C1-01 and C1-02 are the factory default active accel/decel settings. Alternate accel/decel settings (C1-03 through C1-08) can be activated by multi-function digital inputs (H1-0 = 7 and 1A), or specified by the switch over frequency (C1-11). See Fig 5.7 below. Output Frequency C1-11 C1-07 Rate C1-01 Rate C1-02 Rate C1-08 Rate Time Fig 5.7 Acceleration/deceleration Time Switch Over Frequency Basic Programming 5 - 8 Carrier Frequency C6-02 Carrier Frequency Selection Setting 0 1 2 3 4 5 6 F Description Low Noise Fc=2.0 kHz Fc=5.0 kHz Fc=8.0 kHz Fc=10.0 kHz Fc=12.5 kHz Fc=15.0 kHz Program *The factory default setting is model dependent Parameter C6-02 sets the switching frequency of the Drive’s output transistors. It can be changed in order to reduce audible carrier noise and also reduce leakage current. Cases that may require adjustment to the C6-02 include: • • • • If the wiring length between the Drive and the motor is long, decrease the carrier frequency. Wiring Length 164 ft or less 328 ft or less Over 328 ft C6-02 (carrier frequency) setting 1 to 6 (15 kHz max.) 1 to 4 (10 kHz max.) 1 to 2 (5 kHz max.) If speed and torque are inconsistent at low speeds, decrease the carrier frequency. If leakage current from the Drive is large, decrease the carrier frequency. If the audible motor noise is too great, increase the carrier frequency. The setting range depends on setting of parameter C6-01 Heavy/Normal Duty Selection. If Heavy Duty is selected (C6-01=0), the default Carrier Frequency setting is 1=2 kHz. Software version VSF103021 and higher allows the carrier frequency to be increased above the 2 kHz setting (on most models). However, the continuous rated output current will automatically be reduced to the level as indicated in the following table. Note: Increasing the carrier frequency above 2 kHz while in Heavy Duty (C6-01=1) may result in overload (OL2) shutdown if the load current is above the continuous current rating in the following table. If Normal Duty 1 (C6-01=1) or Normal Duty 2 (C6-01=2) is selected, Carrier Frequency Selection range is “0” (Low Noise) to “F” (Program). Setting of “F: Program” allows the carrier frequency to be varied according to parameters C6-03 (Carrier Frequency Upper Limit), C6-04 (Carrier Frequency Lower Limit), and C6-05 (Carrier Frequency Proportional Gain). Basic Programming 5 - 9 Table 5.1 HD Ratings for Various Carrier Frequencies Model CIMR-F7U Continuous Amps (A) *1 Carrier Frequency 8.0 kHz 10.0 kHz 2.9 2.8 3.8 3.7 6.4 6.2 8.8 8.4 13.9 13.4 21 20.2 28.3 27.3 41 39.6 52.9 51 64.8 62.5 77.5 74.8 96.8 90.2 106.7 92.8 2.0 kHz 3.2 4.2 7 9.6 15.2 23 31 45 58 71 85 115 145 5.0 kHz 3.1 4 6.7 9.2 14.6 22.1 29.8 43.2 55.7 68.2 81.6 106.7 127.6 180 215 283 346 158.4 189.2 249 304.5 132.5 158.2 208.3 254.7 115.2 137.6 181.1 221.4 40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 360*2 1.8 2.1 3.7 5.3 7.6 8.7 12.5 17 24 31 39 45 60 75 1.7 2 3.6 5.1 7.3 8.4 12 16.3 23 29.8 37.4 43.2 55.7 69.6 1.6 1.9 3.4 4.8 6.9 7.9 11.4 15.5 21.9 28.3 35.6 41 50.5 63.2 1.6 1.8 3.3 4.7 6.7 7.7 11 15 21.1 27.3 34.3 39.6 47 58.8 1.5 1.8 3.1 4.5 6.4 7.3 10.5 14.3 20.2 26.0 32.8 37.8 42.7 53.4 1.4 1.7 3.0 4.2 6.1 7.0 10.0 13.6 19.2 24.8 31.2 36.0 38.4 48.0 4045 4055 4075 4090 4110 4132 4160 4185 91 112 150 180 216 260 304 370 84.4 103.9 132 158.4 190.1 228.8 267.5 296 76.6 94.3 110.4 132.5 159 191.4 223.7 71.3 87.8 96 115.2 138.2 166.4 194.6 64.8 79.7 58.2 71.7 4220 414*2 4300 *2 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110 12.5 kHz 2.7 3.5 5.9 8.1 12.8 19.3 26.0 37.8 48.7 59.6 71.4 81.9 15.0 kHz 2.6 3.4 5.6 7.7 12.2 18.4 24.8 36.0 46.4 56.8 68.0 73.6 No Increase in Carrier Frequency Possible No Increase in Carrier Frequency Possible 590 *1 All models have an overload rating of 150% of rated output current for 60 seconds except model 2110, which has an overload rating of 138% of rated output current for 60 seconds, and models 4220 and 4300, which have an overload rating of 150% of rated output current for 45 seconds. *2 Heavy Duty Ratings for models 2110, 4220 and 4300 are effective in software version VSF103021 and higher. Basic Programming 5 - 10 Preset Reference d1-01 Frequency Reference 1 d1-02 Frequency Reference 2 d1-03 Frequency Reference 3 d1-04 Frequency Reference 4 Setting Range: 0.0 to E1-04 (Maximum Output Frequency) Factory Default: 0.0Hz d1-17 Jog Reference Setting Range: 0.0 to E1-04 (Maximum Output Frequency) Factory Default: 6.0Hz Up to 17 preset references (including Jog Reference) can be set through multi-function inputs S3 to S8. The first 4 preset references and Jog Reference are accessible through the Quick Setting menu. It is a two-step process to set the Drive up for preset speeds. First, d1-01 through d1-04 and d1-17 must be programmed with the desired preset speeds and the desired jog speed, respectively. Next, three of the Drive’s digital inputs need to be programmed and wired as Multi-step Speed Reference 1, Multi-step Speed Reference 2, and Jog Frequency. Table 5.2 Preset Speed Preset Speed Terminal programmed as Multi-step Reference 1 Terminal programmed as Multi-step Reference 2 Terminal programmed as Jog Reference Details 1 OFF OFF OFF Frequency Reference 1 (d1-01) or analog input A1 2 ON OFF OFF Frequency Reference 2 (d1-02) or analog input A3 3 OFF ON OFF Frequency Reference 3 (d1-03) 4 ON ON OFF Frequency Reference 4 (d1-04) 5 - - ON* Jog Frequency (d1-17) * The Jog Frequency input is given priority over the multi-step speeds. As shown in the above table, it is possible to use analog inputs in place of Frequency Reference 1 and Frequency Reference 2. If b1-01 = 1, then the analog input A1 will be used instead of Frequency Reference 1 for the first preset speed. If b1-01=0 then Frequency Reference 1 (d1-01) will be used. If H3-05 = 2, then the analog input A2 will be used instead of Frequency Reference 2 (d1-02) for the second preset speed. If H3-05 ≠ 2, then Frequency Reference 2 will be used. IMPORTANT The programming of d1-01 through d1-17 will be in the units specified by the display scaling parameter (o1-03). Basic Programming 5 - 11 Input Voltage Setting E1-01 Input Voltage Setting Setting Range: 155.0V to 255.0V (240V Models) 310.0V to 510.0V (480V Models) Factory Defaults: 230.0V (240V Models) 460.0V (480V Models) Set the Input Voltage parameter (E1-01) to the nominal voltage of the connected AC power supply. This parameter adjusts the levels of some protective features of the Drive (i.e. Overvoltage, Built-in Braking Transistor Turn-on, Stall Prevention, etc.). E1-01 also serves as the Maximum/Base Voltage used by the Preset V/F curves (E1-03=0 to E). WARNING DRIVE INPUT VOLTAGE (NOT MOTOR VOLTAGE) MUST BE SET IN E1-01 FOR THE PROTECTIVE FEATURES OF THE DRIVE TO FUNCTION PROPERLY. FAILURE TO DO SO MAY RESULT IN EQUIPMENT DAMAGE AND/OR PERSONAL INJURY. V/F Pattern E1-03 V/F Pattern Selection Setting 0 1 2 3 4 5 6 7 8 9 A B C D E F FF Description 50Hz 60Hz 60Hz (with 50Hz Base) 72Hz (with 60Hz Base) 50Hz VT1 50Hz VT2 60Hz VT1 60Hz VT2 50Hz HST1 50Hz HST2 60Hz HST1 60Hz HST2 90Hz (with 60Hz Base) 120Hz (with 60Hz Base) 180Hz (with 60Hz Base) Custom V/F (factory default) Custom w/o limit Note: VT = Variable Torque, HST = High Starting Torque Basic Programming 5 - 12 This parameter is only available in the V/F or V/F with PG control methods (A1-02 = 0 or 1). The Drive operates utilizing a set V/F pattern to determine the appropriate output voltage level for each commanded speed. There are 15 different preset V/F patterns to select from (E1-03 = 0 to E) with varying voltage profiles, base level (base level = frequency at which maximum voltage is reached), and maximum frequencies. There are also settings for Custom V/F patterns that will use the settings of parameters E1-04 through E1-13. E1-03 = F selects a custom V/F pattern with an upper voltage limit and E1-03 = FF selects a custom V/F pattern without an upper voltage limit. See Fig 5.8 below for the upper voltage limit. Voltage Upper Limits for 208-240V Class Drives Output Voltage 250V B A E1-06 / 40 E1-06 Output Frequency F7U20P4-23P7 A = 5V B = 35V F7U24P0-2045 A = 2.5V B = 20V F7U2055 & higher A = 2.5V B = 15V For 480V class Drives, the values are twice that of 208-240V class Drives. Fig 5.8 V/F Pattern Voltage Upper Limit Basic Programming 5 - 13 Specifications E1-03 Table 5.3 Preset V/F Patterns V/F Pattern Specifications (V) 230 0 General-purpose 17 10 0 1.3 2.5 60Hz 60Hz (with 50Hz Base) 1 or F 50 (Hz) (V) 230 2 High Starting Torque 50Hz 0 17 10 0 1.5 3.0 (V) 230 8 9 High Starting Torque 2 9 High Starting Torque 1 A 50 60 High Starting Torque 2 (Hz) 3 90Hz (with 60Hz Base) 3 B 5 Variable Torque Variable Torque 1 57 40 5 6 4 10 9 0 1.3 25 50 (Hz) 57 40 7 (V) 230 A 28 22 17 13 0 1.5 3.0 60 (Hz) 17 10 0 1.5 3.0 60 90 (Hz) (V) 230 120Hz (with 60Hz Base) D D 17 10 0 1.5 3.0 (Hz) 60 120 (V) 230 180Hz (with 60Hz Base) 7 Variable Torque 2 (Hz) C (V) 230 60Hz IMPORTANT 60 72 (V) 230 50Hz Variable Torque 2 50 C (Hz) High Speed Operation 4 8 (V) 230 17 10 0 1.5 3.0 Variable Torque 1 28 22 15 13 0 1.3 2.5 B (V) 230 72Hz (with 60 Hz Base) V/F Pattern 60Hz 1 F 2 50Hz High Starting Torque 1 E1-03 6 10 9 0 1.5 30 60 (Hz) E E 17 10 0 1.5 3.0 60 (Hz) 180 When a factory initialization is performed and the setting of E1-03 = F or FF, E1-03 is unaffected, but the settings of E1-04 through E1-13 are returned to their factory default settings. Basic Programming 5 - 14 E1-04 Maximum Output Frequency Setting Range: 40.0 to 400.0Hz Factory Default: 60.0Hz E1-05 Maximum Output Voltage Setting Range: 0.0 to 255.0V (240V Models) 0.0 to 510.0V (480V Models) Factory Defaults: 230.0V (240V Models) 460.0V (480V Models) E1-06 Base Frequency Setting Range: 0.0 to 400.0Hz Factory Default: 60.0Hz E1-09 Minimum Output Frequency Setting Range: 0.0 to 400.0Hz (Normal Duty) 0.0 to 300.0Hz (Heavy Duty) Factory Default: 1.5Hz E1-13 Base Voltage Setting Range: 0.0 to 255.0V (240V Models) 0.0 to 510.0V (480V Models) Factory Defaults: 0.0V (240V Models) 0.0V (480V Models) To set up a custom V/F pattern, program the points shown in the diagram below using parameters E1-04 through E1-13. Be sure that the following condition is true: E1-09 ≤ Ε1−07 < Ε1−06 ≤ Ε1−11 ≤ Ε1−04 Voltage Max Voltage E1-05 Mid Voltage B E1-12 Base Voltage E1-13 Mid Voltage A E1-08 Min Voltage E1-10 E1-09 E1-07 E1-06 E1-11 E1-04 Frequency Min Mid Mid Base Mid Max A Freq Freq B Freq Freq Freq Freq A Fig 5.9 V/F Pattern Parameters Parameters E1-07, E1-08, E1-10, E1-11, and E1-12 are accessible through the Programming Menu. Basic Programming 5 - 15 Tables 5.3 to 5.5 list the factory settings of V/F patterns when V/F without PG or V/F with PG control method is selected (A1-02 = 0 or 1). Table 5.3 V/F Pattern for Drive Capacity F7U20P4 - 21P5 for 200V Class Parameter No. Name Unit Factory Setting E1-03 V/F Pattern Selection — 0 1 2 3 4 5 6 7 E1-04 Max. Output Frequency Hz 50.0 60.0 60.0 72.0 50.0 50.0 60.0 60.0 E1-05 Max. Output Voltage V 230.0 230.0 230.0 230.0 230.0 230.0 230.0 230.0 E1-06 Base Frequency Hz 50.0 60.0 50.0 60.0 50.0 50.0 60.0 60.0 E1-07 Mid. Output Frequency V 2.5 3.0 3.0 3.0 25.0 25.0 30.0 30.0 E1-08 Mid. Output Voltage V 17.2 17.2 17.2 17.2 40.2 57.5 40.2 57.5 E1-09 Min. Output Frequency Hz 1.3 1.5 1.5 1.5 1.3 1.3 1.5 1.5 E1-10 Min. Output Voltage V 10.3 10.3 10.3 10.3 9.2 10.3 9.2 10.3 1. For 400V class units, the voltage values are twice that of 200V class units. 2. These default values are for V/F or V/F with PG control methods (A1-02 = 0 or 1) Table 5.3 V/F Pattern for Drive Capacity F7U20P4 - 21P5 for 200V Class (continued) Parameter No. Name Unit Factory Setting E1-03 V/F Pattern Selection — 8 9 A B C D E F & FF E1-04 Max. Output Frequency Hz 50.0 50.0 60.0 60.0 90.0 120.0 180.0 60.0 E1-05 Max. Output Voltage V 230.0 230.0 230.0 230.0 230.0 230.0 230.0 230.0 E1-06 Base Frequency Hz 50.0 50.0 60.0 60.0 60.0 60.0 60.0 60.0 E1-07 Mid. Output Frequency V 2.5 2.5 3.0 3.0 3.0 3.0 3.0 3.0 E1-08 Mid. Output Voltage V 21.8 27.6 21.8 27.6 17.2 17.2 17.2 17.2 E1-09 Min. Output Frequency Hz 1.3 1.3 1.5 1.5 1.5 1.5 1.5 1.5 E1-10 Min. Output Voltage V 12.6 14.9 12.6 17.2 10.3 10.3 10.3 10.3 1. For 400V class units, the voltage values are twice that of 200V class units. 2. These default values are for V/F or V/F with PG control methods (A1-02 = 0 or 1) Basic Programming 5 - 16 Table 5.4 V/F Pattern for Drive Capacity F7U22P2 - 2045 for 200V Class Parameter No. Name Unit Factory Setting E1-03 V/F Pattern Selection — 0 1 2 3 4 5 6 7 E1-04 Max. Output Frequency Hz 50.0 60.0 60.0 72.0 50.0 50.0 60.0 60.0 E1-05 Max. Output Voltage V 230.0 230.0 230.0 230.0 230.0 230.0 230.0 230.0 E1-06 Base Frequency Hz 50.0 60.0 50.0 60.0 50.0 50.0 60.0 60.0 E1-07 Mid. Output Frequency V 2.5 3.0 3.0 3.0 25.0 25.0 30.0 30.0 E1-08 Mid. Output Voltage V 16.1 16.1 16.1 16.1 40.2 57.5 40.2 57.5 E1-09 Min. Output Frequency Hz 1.3 1.5 1.5 1.5 1.3 1.3 1.5 1.5 E1-10 Min. Output Voltage V 8.0 8.0 8.0 8.0 6.9 8.0 6.9 8.0 1. For 400V class units, the voltage values are twice that of 200V class units. 2. These default values are for V/F or V/F with PG control methods (A1-02 = 0 or 1) Table 5.4 V/F Pattern for Drive Capacity F7U22P2 - 2045 for 200V Class (continued) Parameter No. Name Unit Factory Setting E1-03 V/F Pattern Selection — 8 9 A B C D E F& FF E1-04 Max. Output Frequency Hz 50.0 50.0 60.0 60.0 90.0 120.0 180.0 60.0 E1-05 Max. Output Voltage V 230.0 230.0 230.0 230.0 230.0 230.0 230.0 230.0 E1-06 Base Frequency Hz 50.0 50.0 60.0 60.0 60.0 60.0 60.0 60.0 E1-07 Mid. Output Frequency V 2.5 2.5 3.0 3.0 3.0 3.0 3.0 3.0 E1-08 Mid. Output Voltage V 20.7 26.4 20.7 26.4 16.1 16.1 16.1 16.1 E1-09 Min. Output Frequency Hz 1.3 1.3 1.5 1.5 1.5 1.5 1.5 1.5 E1-10 Min. Output Voltage V 10.3 12.6 10.3 14.9 8.0 8.0 8.0 8.0 1. For 400V class units, the voltage values are twice that of 200V class units. 2. These default values are for V/F or V/F with PG control methods (A1-02 = 0 or 1) Basic Programming 5 - 17 Table 5.5 V/F Pattern for Drive Capacity F7U2055 and higher for 200V Class Parameter No. Name E1-03 V/F Pattern Selection E1-04 Unit Factory Setting – 0 1 2 3 4 5 6 7 Max. Output Frequency Hz 50.0 60.0 60.0 72.0 50.0 50.0 60.0 60.0 E1-05 Max. Output Voltage V 230.0 230.0 230.0 230.0 230.0 230.0 230.0 230.0 E1-06 Max. Voltage Frequency Hz 50.0 60.0 50.0 60.0 50.0 50.0 60.0 60.0 E1-07 Mid. Output Frequency V 2.5 3.0 3.0 3.0 25.0 25.0 30.0 30.0 E1-08 Mid. Output Voltage V 13.8 13.8 13.8 13.8 40.2 57.5 40.2 57.5 E1-09 Min. Output Frequency Hz 1.3 1.5 1.5 1.5 1.3 1.3 1.5 1.5 E1-10 Min. Output Voltage V 6.9 6.9 6.9 6.9 5.7 6.9 5.7 6.9 1. For 400V class units, the voltage values are twice that of 200V class units. 2. These default values are for V/F or V/F with PG control methods (A1-02 = 0 or 1) Table 5.5 V/F Pattern for Drive Capacity F7U2055 and higher for 200V Class (continued) Parameter No. Name E1-03 V/F Pattern Selection E1-04 Unit Factory Setting – 8 9 A B C D E F & FF Max. Output Frequency Hz 50.0 50.0 60.0 60.0 90.0 120.0 180.0 60.0 E1-05 Max. Output Voltage V 230.0 230.0 230.0 230.0 230.0 230.0 230.0 230.0 E1-06 Base Frequency Hz 50.0 50.0 60.0 60.0 60.0 60.0 60.0 60.0 E1-07 Mid. Output Frequency V 2.5 2.5 3.0 3.0 3.0 3.0 3.0 3.0 E1-08 Mid. Output Voltage V 17.2 23.0 17.2 23.0 13.8 13.8 13.8 13.8 E1-09 Min. Output Frequency Hz 1.3 1.3 1.5 1.5 1.5 1.5 1.5 1.5 E1-10 Min. Output Voltage V 8.0 10.3 8.0 12.6 6.9 6.9 6.9 6.9 1. For 400V class units, the voltage values are twice that of 200V class units. 2. These default values are for V/F or V/F with PG control methods (A1-02 = 0 or 1) Basic Programming 5 - 18 Table 5.6 lists the factory settings of V/F patterns when open loop vector or flux vector control method is selected (A1-02 = 2 or 3). Table 5.6 V/F Pattern for 200V Class Drives Factory Setting Parameter No. Name Unit Open Loop Vector Flux Vector E1-04 Max. Output Frequency Hz 60.0 60.0 E1-05 Max. Output Voltage V 230.0 230.0 E1-06 Base Frequency Hz 60.0 60.0 E1-07 Mid. Output Frequency V 3.0 0.0 E1-08 Mid. Output Voltage V 12.6 0.0 E1-09 Min. Output Frequency Hz 0.5 0.0 E1-10 Min. Output Voltage V 2.3 0.0 1. For 400V class units, the voltage values are twice that of 200V class units. 2. These default values are for open loop vector or flux vector control methods (A1-02 = 2 or 3) Basic Programming 5 - 19 Motor Setup E2-01 Motor Rated Current Setting Range: Model Dependent Factory Default: Model Dependent The Motor Rated Current parameter (E2-01) is used by the Drive to protect the motor and for proper Vector control when using Open Loop Vector or Flux Vector control methods (A1-02 = 2 or 3). The motor protection parameter L1-01 is enabled by default. Set E2-01 to the full load amps (FLA) stamped on the motor’s nameplate. During Auto-Tuning, it is required for the operator to enter the motor’s rated current (T1-04) in the Auto-Tuning menu. If the Auto-Tuning operation completes successfully, the value entered into T1-04 will automatically be written into E2-01. E2-04 Number of Motor Poles Setting Range: 2 to 48 Factory Default: 4 This parameter sets the number of motor poles. During Auto-Tuning, it is required for the operator to enter the number of motor poles (T1-06) in the Auto-Tuning menu. If the Auto-Tuning operation completes successfully, the value entered into T1-06 will automatically be written into E2-04. E2-11 Motor Rated Power Setting Range: 0.00 to 650.00kW Factory Default: Varies by kVA This parameter sets the motor rated power is set in kilowatts (kW). 1HP = 0.746kW During Auto-Tuning, it is required for the operator to enter the motor’s rated power (T1-02) in the Auto-Tuning menu. If the Auto-Tuning operation completes successfully, the value entered into T1-02 will automatically be written into E2-11. PG Option F1-01 PG Pulses / Revolution Setting Range: 0 to 60000 Factory Default: 1024 If a PG encoder option is used with the Drive, the number of PG pulses per motor revolution (PPR) must be set. During Auto-Tuning, it is required for the operator to enter the PG pulses per revolution (T1-08) in the Auto-Tuning menu. If the Auto-Tuning operation completes successfully, the value entered into T1-08 will automatically be written into F1-01. Basic Programming 5 - 20 Analog Output Gain H4-02 Terminal FM Gain Setting Range: 0.0 to 1000.0 Factory Default: 100.0% H4-05 Terminal AM Gain Setting Range: 0.0 to 1000.0 Factory Default: 50.0% These parameters set the gains for the analog output terminals FM and AM. The analog outputs are used for external monitoring of Drive conditions, such as output frequency, output current, PID feedback, and others. To obtain the output level, multiply the monitor output level by the gain set in H4-02 or H4-05. Analog Output Level For example, if H4-02=150%, then the FM analog output will output 10Vdc when the assigned output function reaches the 67% level. The analog output has a maximum of 10Vdc. 10V x 150% 10V 0 67 100 Output Function Level (%) Fig 5.10 Analog Output Gain Setting Example Basic Programming 5 - 21 Motor Overload Fault L1-01 Motor Overload Fault Selection Setting Description 0 Disabled 1 Standard Fan Cooled Motor (<10:1 motor) (factory default) 2 Standard Blower Cooled Motor (≥10:1 motor) 3 Vector Motor (≤1000:1 motor) The Drive has an electronic overload protection function (OL1) for protecting the motor from overheating. The Drive bases the protection on time, output current, and output frequency. The electronic thermal overload function is UL-recognized, so an external thermal overload relay is not required for single motor operation. This parameter selects the motor overload curve used according to the type of motor applied. Setting L1-01 = 1 selects a motor with limited cooling capability below rated (base) speed when running at 100% load. The OL1 function derates the motor any time it is running below base speed. Setting L1-01 = 2 selects a motor capable of cooling itself over a 10:1 speed range when running at 100% load. The OL1 function derates the motor when it is running at 1/10 of its rated speed or less. Setting L1-01 = 3 selects a motor capable of cooling itself at any speed when running at 100% load. This includes zero speed. The OL1 function does not derate the motor at any speed. If the Drive is connected to a single motor, the motor overload protection should be enabled (L1-01=1, 2, or 3) unless another means of preventing motor thermal overload is provided. When the electronic thermal overload function is activated, an OL1 fault occurs, shutting OFF the Drive’s output thus preventing additional overheating of the motor. The motor temperature is continually calculated as long as the Drive is powered up. When operating several motors with one Drive, install a thermal relay on each motor and disable the motor overload protection (L1-01=0). Basic Programming 5 - 22 Stall Prevention L3-04 Stall Prevention During Deceleration Selection Setting Description 0 Disabled 1 General purpose (Enabled) (factory default) 2 Intelligent stall prevention (Enabled) 3 Stall prevention with DB resistor (Enabled) The stall prevention during deceleration function adjusts the deceleration time in order to prevent OV fault trips during deceleration. If L3-04=0, stall prevention is disabled, and if the load is large and the deceleration time short enough, the Drive may fault and stop. If L3-04=1, the standard stall prevention function is enabled. If, during deceleration, the DC Bus voltage exceeds the stall prevention level (see table below), the Drive will discontinue decelerating and maintain speed. Once the DC Bus voltage has dropped below the stall prevention level, deceleration will continue. Fig 5.11 demonstrates deceleration when L3-04=1. Drive Voltage Stall Prevention Level during Deceleration 240Vac 380Vdc 480Vac E1-01 ≥ 400Vac 760Vdc E1-01 < 400Vac 660Vdc a - Set decel time b - Decel time is extended Output Frequency t a a b b DC Bus Voltage 380/660/760Vdc t Fig 5.11 Stall Prevention Basic Programming 5 - 23 If L3-04=2, the intelligent stall prevention function is enabled. The active deceleration time is used as a starting point and the Drive will attempt to decelerate as quickly as possible without causing the DC Bus voltage to exceed the stall prevention level. The fastest time possible is 1/10 the active deceleration time. If L3-04=3, the stall prevention with braking resistor function is enabled. The DC bus voltage level is controlled during fast deceleration and allows for a faster than normal deceleration time. Use this setting with a braking resistor when overvoltage fault (OV) sometimes occurs even under settings 1 or 2. IMPORTANT In Flux Vector Control Mode (A1-02=3), setting stall prevention with DB resistor (L3-04=3) cannot be done. Basic Programming 5 - 24 Chapter 6 Diagnostics & Troubleshooting This chapter describes diagnostics and troubleshooting for the Drive. Fault Detection ............................................................................. 6-2 Alarm Detection.......................................................................... 6-10 Operator Programming Errors (OPE)......................................... 6-15 Auto-Tuning Faults..................................................................... 6-17 Digital Operator COPY Function Faults ..................................... 6-19 Troubleshooting ......................................................................... 6-20 Main Circuit Test Procedure....................................................... 6-28 Drive Date Stamp Information .................................................... 6-31 Diagnostics & Troubleshooting 6 - 1 Fault Detection When the Drive detects a fault, the fault information is displayed on the Digital Operator, the fault contact closes, and the motor coasts to stop. (However, a fault with selectable stopping method will operate according to the stopping method selected.) • If a fault occurs, take appropriate action according to the table by investigating the cause. • To restart, reset the fault with any of the following procedures: •Set “14: Fault Reset” to a multi-function digital input (H1-01 to H1-06). Then, close and open the input. •Press the RESET key of the Digital Operator. •Shut off the Drive input power, and then turn on again. Table 6.1 Fault Displays and Processing Digital Operator Display Cause Corrective Action Option Communication Error After initial communication was established, the connection was lost. Connection was broken and/or master controller stopped communicating. Check all connections and verify all user-side software configurations. CE Memobus Com Err Modbus Communication Error Control data was not received correctly for two seconds. This fault is detected when H5-05=1 and H5-04=0 to 2. Connection was broken and/or master has stopped communicating. Check all connections and verify all user-side software configurations. CF Out of Control Control Fault A torque limit was reached continuously for 3 seconds or longer during a ramp to stop while in open-loop vector control. Motor parameters were not set properly. Check motor parameters. Perform Auto-Tuning. Operator Communication Fault Transmission between the Drive and the Digital Operator was not established within 5 seconds after supplying power. Digital Operator cable was not securely connected, Digital Operator defective, and/or control board defective. Remove the Digital Operator, and then reinstall it. External RAM of CPU was defective. Control circuit was damaged. BUS Option Com Err CPF00 COM-ERR(OP&INV) Description Cycle power to the Drive. Replace the control board. Operator Communication Fault After communication started with the CPF01 COM-ERR(OP&INV) Digital Operator, communication stopped for 2 seconds or more. Digital Operator cable was not securely connected, Digital Operator defective, and/or control board defective. Remove the Digital Operator once and then reinstall it. Cycle power to the Drive. Replace the Digital Operator and/ or the control board. Perform a factory initialization. CPF02 BB Circuit Err Baseblock Circuit Fault Baseblock circuit fault at power-up. Gate array hardware failure during power-up. Cycle power to the Drive. Replace the control board. Perform factory initialization. CPF03 EEPROM Error EEPROM Fault Check sum was not valid. Noise or spike was on the control circuit input terminals. Cycle power to the Drive. Replace the control board. Perform factory initialization. CPF04 Internal A/D Err CPU Internal A/D Converter Fault Noise or spike was on the control circuit input terminals. Cycle power to the Drive. Replace the control board. Diagnostics & Troubleshooting 6 - 2 Table 6.1 Fault Displays and Processing (continued) Digital Operator Display Description Cause Corrective Action Perform a factory initialization. CPF05 External A/D Err External A/D Converter Fault Noise or spike was on the control circuit input terminals. Cycle power to the Drive. Replace the control board. CPF06 Option Error Option Board Connection Error Turn off the power and reinstall the option board. The Drive or option board was damaged. Replace the option board or the Drive. Control circuit failure/damage. Cycle power to the Drive. CPF07 RAM-Err ASIC Internal RAM Fault CPF08 WAT-Err Watchdog Timer Fault CPF09 CPU-Err CPU-ASIC Mutual Diagnosis Fault CPF10 ASIC-Err ASIC Version Fault CPF20 Option A/D Error The option board was not connected properly. Control circuit damage. Replace the Drive. Control circuit failure/damage. Cycle power to the Drive. Control circuit damage. Replace the Drive. Control circuit failure/damage. Cycle power to the Drive. Control circuit damage. Replace the Drive. Control circuit damage. Replace the Drive. Option board input fault. Remove all inputs to the option board. Perform a factory initialization. Option Card Fault Cycle power to the Drive. Option card A/D convert fault. Replace the option board. Replace the control board. Perform a factory initialization. CPF21 Option CPU Down Self-diagnosis Fault of Option Board Noise or spike was on the communication line and/or defective option board. Cycle power to the Drive. Replace the option board. Replace the control board. Remove any option boards. CPF22 Option Type Err Option Board Code Number Fault Unrecognizable option board was connected to the control board. Cycle power to the Drive. Perform a factory initialization. Replace the option board. Replace the control board. Remove power to the Drive. CPF23 Option DPRAM Err Option Board Interconnection Fault An option board was not correctly connected to the control board, or an option board that was not made for the Drive was attached to the control board. Reconnect the option board. Perform a factory initialization. Cycle power to the Drive. Replace the option board. Replace the control board. Diagnostics & Troubleshooting 6 - 3 Table 6.1 Fault Displays and Processing (continued) Digital Operator Display DEV Speed Deviation Description Excessive Speed Deviation Detected when F1-04 = 0 to 2 and in Flux Vector control method A1-02 = 3. The speed deviation is greater than the setting in F1-10 for a time longer than the setting in F1-11. Cause Corrective Action The load is locked. Reduce the load. The acceleration or deceleration time is too short. Lengthen the acceleration time and deceleration time. The load is too large. Check the mechanical system. The settings in F1-10 and F1-11 are not appropriate for the application. Check the settings in F1-10 and F1-11. Braking mechanism is engaged Check that the brake is released when using brake (motor). Encoder wiring and/or encoder settings (F1 group) are incorrect Check for proper encoder wiring and verify the parameter settings are correct. Check for an external condition. EF0 Opt External Flt Option Board External Fault An external fault condition is present. Verify the parameters. Verify communication signal. EF3 Ext Fault S3 EF4 Ext Fault S4 EF5 Ext Fault S5 EF6 Ext Fault S6 External Fault at Terminal S3 - S8 Detected when terminals S3 - S8 (H1-01 to H1-06) are programmed for external fault function that stops the Drive using ramp to stop, coast to stop, or fast stop. An external fault condition is present that is connected to a multi-function digital input. SI-T Watchdog Error Consistency error of received control data. Synchronization error between master controller and Drive for control data. Eliminate the cause of the external fault condition. EF7 Ext Fault S7 EF8 Ext Fault S8 E5 SI-T WDT Err <3021> Check the communications timing such as communications cycle. Refer to SI-T manual for details. Check the communication signals. E-15 SI-F/G Com Err SI-F/G Communication Error Detected A communication error is detected when a run command or frequency reference is set from the SI-F/G Option Card (b1-01=3, b1-02=3) and communication is lost. Communication has been lost to the SI-F/G option card connected and b1-01=3 and/or b1-02=3. Check the settings of b1-01 and b1-02. Check the setting of F6-01. Check the host side (master) communication configuration. Diagnostics & Troubleshooting 6 - 4 Table 6.1 Fault Displays and Processing (continued) Digital Operator Display FAN Cooling FAN Err <3021> FBL Feedback Loss Description Cause Drive’s Cooling Fan Fault A Drive’s cooling fan fault was detected, The Drive continued running and the Drive overload protection was with an overload after the activated based on the internal electric cooling fan stopped. thermal value. This fault is detected when L8-32 is set to 1. PID Feedback Loss This fault occurs when PID Feedback Loss Detection is programmed to fault (b5-12 = 2) and the PID Feedback < PID Feedback Loss Detection Level (b5-13) for the PID Feedback Loss Detection Time (b5-14). PID feedback source (e.g. transducer, sensor, building automation signal) is not installed correctly or is not working. Corrective Action Replace the cooling fan. Verify Drive is programmed to receive the PID feedback source signal. Check to ensure the PID feedback source is installed and working properly. Remove the motor and run the Drive without the motor. GF Ground Fault LF Output Phase Loss Output Ground Fault Drive output grounding current has exceeded 50% of the Drive rated output current and L8-09 = 1 (enabled). Motor lead was shorted to ground and/or a DCCT was defective. There was a broken wire in the output cable. There was a broken wire in the motor winding. The output terminals were Output Open-phase An open-phase occurred at the Drive output loose. This fault is detected when output current The motor being used has a has exceeded 5% imbalance and L8-07 = 1 capacity less than 5% of the (enabled). Drive’s maximum motor capacity. Low impedance motor was used. OC Over Current Overcurrent Drive output current exceeded the overcurrent detection level (approximately 200% of Drive rated output current). Shorted Drive output phase to phase, shorted motor, locked rotor, load too heavy, accel/ decel time too short, contactor on the Drive output is opened or closed, a special motor or a motor with a FLA rating larger than Drive rated output current. Check the motor for a phase to ground short. Check the output current with a clamp on meter to verify the DCCT reading. Check the wiring to the motor. Check the motor for phase to ground short. Check the motor and Drive capacity. Add additional impedance. Remove the motor and run the Drive without the motor. Check the motor for a phase-tophase short. Check the Drive for a phase-tophase short at the output. Verify C1-01 and C1-02 are set correctly. Check load conditions. Heatsink Overheat The temperature of the Drive’s heatsink OH Heatsink Overtemp exceeded the setting in L8-02 and L8-03 = 0 to 2. There was a heat source nearby. Check for dirt build-up on the fans and heatsink. The ambient temperature was too high. Reduce the ambient temperature around the Drive. Diagnostics & Troubleshooting 6 - 5 Table 6.1 Fault Displays and Processing (continued) Digital Operator Display Description Heatsink Overheat The temperature of the Drive’s heatsink OH exceeded the setting in L8-02 and Heatsink Overtemp L8-03 = 0 to 2. (Continued) Drive’s internal cooling fan stopped (F7U2018 / F7U4018 and larger). OH1 Heatsink Max Temp Heatsink Overheat The temperature of the Drive’s heatsink exceeded 105 degrees C. Cause Corrective Action The Drive’s cooling fan(s) stopped. Replace the cooling fan. The Drive’s internal cooling fan(s) stopped. There was a heat source nearby. Check for dirt build-up on the fans and heatsink. The ambient temperature was too high. Reduce the ambient temperature around the Drive. The Drive’s cooling fan(s) stopped. Replace the cooling fan. Drive’s internal cooling fan stopped The Drive’s internal cooling (F7U2011 / F7U4011 and larger capacities). fan(s) stopped. Recheck the cycle time and the size of the load. OH3 Motor Overheat 1 Motor Overheating 1 Detected when A2 or A3, programmed for motor temperature (H3-09 or H3-05 = E), exceeds 1.17V for time L1-05 and L1-03 = 0 to 2. Overheating of motor as measured by the motor thermistor. Recheck the accel/decel time (C1-01 and C1-02). Recheck the V/F pattern (E1-01 thru E1-13). Recheck the motor rated current value (E2-01). Recheck the cycle time and the size of the load. OH4 Motor Overheat 2 Motor Overheating 2 Detected when A2 or A3, programmed for motor temperature (H3-09 or H3-05 = E), exceeds 2.34V for time L1-05 and L1-03 = 0 to 2. Overheating of motor as measured by the motor thermistor. Recheck the accel/decel time (C1-01 and C1-02). Recheck the V/F pattern (E1-01 thru E1-13). Recheck the motor rated current value (E2-01). OL1 Motor Overloaded Motor Overload Detected when L1-01 = 1 to 3 and the Drive’s output current exceeded the motor overload curve. The overload curve is adjustable using parameter E2-01, L1-01, and L1-02. The load was too large. The cycle time was too short at the accel/decel time. Recheck the cycle time and the size of the load as well as the times set in C1-01 and C1-02 The voltage of the V/F pattern was incorrect for the application. Review the V/F pattern parameters, E1-01 thru E1-13. Motor rated current setting was improper. Check the motor rated current value in E2-01. Diagnostics & Troubleshooting 6 - 6 Table 6.1 Fault Displays and Processing (continued) Digital Operator Display Description Cause Corrective Action Recheck the cycle time and the The load was too large, or the size of the load as well as the times accel/decel times are too short. set in C1-01 and C1-02. OL2 Inv Overload Drive Overload The Drive output current exceeded the Drive’s overload curve. The voltage of the V/F pattern was incorrect for the application. Review the V/F pattern parameters, E1-01 thru E1-13. The size of the Drive was too small. Change to a larger size Drive. Ensure the values in L6-02 and L603 are appropriate. OL3 Overtorque Det 1 Overtorque Detection 1 Drive output current > L6-02 for more than the time set in L6-03 and L6-01 = 3 or 4. OL4 Overtorque Det 2 Overtorque Detection 2 Drive output current > L6-05 for more than the time set in L6-06 and L6-04 = 3 or 4. Motor was overloaded. OL7 HSB OL High Slip Braking OL The output frequency stayed constant for longer than the time set in n3-04 during high slip braking. The inertia of the load is too large. OPR Oper Disconnect Digital Operator Connection Fault Detected when the Digital Operator is removed and the Drive is commanded to run through the Digital Operator (b1-02 = 0). The Digital Operator was not attached, or the Digital Operator connector was broken. OS Overspeed Det OV DC Bus Overvolt Motor Overspeed Detected when F1-03 = 0 to 2 and A1-02 = 1 or 3. The motor speed feedback (U1-05) exceeded the setting in F1-08 for a longer time than the setting in F1-09. DC Bus Overvoltage The DC bus voltage has exceeded the trip point. 208-240Vac: Trip point is 410Vdc 480Vac: Trip point is 820Vdc Motor was overloaded. Check application/machine status to eliminate fault. Ensure the values in L6-05 and L606 are appropriate. Check application/machine status to eliminate fault. Make sure the load is an inertial. If possible, reduce the load inertia. Attach the Digital Operator. Check the Digital Operator connector. Verify the setting of o2-06. Overshooting/Undershooting was occurring. Adjust the ASR settings in the C5 parameter group. The reference was too high. Check the reference circuit and reference gain. The settings in F1-08 and F1-09 are not appropriate. Check the settings in F1-08 and F1-09. High input voltage at R/L1, S/L2 and T/L3. Check the input circuit and reduce the input power to within specifications. The deceleration time is set too short. Extend the time in C1-02 or other active decel settings used such as C1-04, C1-06, C1-08, or C1-09 (time). Power factor correction capacitors are being used on the input or output to the Drive. Remove the power factor correction capacitors. Diagnostics & Troubleshooting 6 - 7 Table 6.1 Fault Displays and Processing (continued) Digital Operator Display PF Input Pha Loss PGO PG Open PGOH PG Open HARDWARE <3021> Description Input Phase Loss Drive input power supply has an open phase or has a large imbalance of voltage. Detected when L8-05 = 1 (enabled). PG Disconnection (Detection with Software) Detected when F1-02 = 0 to 2 and A1-02 = 1 or 3. Detected when no PG (encoder) pulses are received for a time longer than the setting in F1-14. PG Disconnection (Detection with Hardware) Detected when F1-02 - 0 to 2 and F1-25 = 1 (PG-T2 or PG-Z2) and / or F1-26 = 1 (PGZ2) and A1-02 = 1 or 3. Detected when no PG (encoder) pulses are received. Cause Corrective Action Open phase on the input of the Drive. Check the input voltage. Loose terminal screws at R/L1, S/L2 or T/L3. Tighten the terminal screws. Momentary power loss occurred. Check the input voltage. Input voltage fluctuation too large. Check the input voltage. There was a break in the PG wiring. Fix the broken / disconnected wiring. The PG was wired incorrectly. Fix the wiring. Power wasn’t being supplied to the PG. Supply power to the PG properly. Braking mechanism is possibly engaged. Check for open circuit when using brake (motor). There is a break in the PG wiring. Fix the broken / disconnected wiring. The PG was wired incorrectly. Fix the wiring. Power is not being supplied to the PG. Supply the proper power required by the PG encoder. — Check for an open circuit when using the brake (motor). Remove power from the Drive. DC Bus Fuse Detects if the DC bus fuse has opened. PUF DC Bus Fuse Open Warning: Never run the Drive after replacing the DC bus fuse without checking for shorted components. Disconnect the motor. Shorted output transistor(s) or terminals. Perform the checks without power in Table 6.6. Replace the shorted component(s). Replace the defective fuse. RH DynBrk Resistor RR DynBrk Transistr Dynamic Braking Resistor The protection of the heatsink mount resistor is activated when L8-01 = 1. This fault is only applicable when using the 3% duty cycle resistor, which is mounted on the Drive’s heatsink. For all other resistors, set L8-01 = 0. Overhauling load, extended dynamic braking duty cycle, defective dynamic braking resistor. Dynamic Braking Transistor The built-in dynamic braking transistor is not operating properly. Started dynamic braking transistor high DC bus voltage, defective dynamic braking resistor. Diagnostics & Troubleshooting 6 - 8 Verify dynamic braking duty cycle. Monitor DC bus voltage. Replace dynamic braking resistor. Cycle power to the Drive. Replace defective dynamic braking transistor or resistor. Monitor DC bus voltage. Table 6.1 Fault Displays and Processing (continued) Digital Operator Display SER Search Retry Err <3021> SVE Zero Servo Fault Description Exceeded Allowable Number of Speed Search Retries The speed search has been retried more than the number of tries set in b3-19 (Number of speed search retrials). Zero Servo Fault The motor position moved more than 10,000 revolutions during zero servo operation. UL3 Undertorq Det 1 Undertorque Detection 1 Drive output current < L6-02 for more than the time set in L6-03 when L6-01 = 7 or 8. UL4 Undertorq Det 2 Undertorque Detection 2 Drive output current < L6-05 for more than the time set in L6-06 when L6-04 = 7 or 8. UV1 DC Bus Undervolt DC Bus Undervoltage 208-240Vac: Default trip point is ≤ 190Vdc 480Vac: Default trip point is ≤ 380Vdc Trip point is adjustable in L2-05. Detected when the DC bus voltage is ≤ L2-05. Cause The settings in b3-17 and b3-18 are not appropriate. Corrective Action Make sure that the settings in b3-17 and b3-18 are appropriate. The torque limit was too small. Increase the torque limit. The load torque was too large. Reduce the load torque. Control circuit fault Check for signal noise. Ensure the values in L6-02 and L6-03 are appropriate. Motor was underloaded. Check application/machine status to eliminate fault. Ensure the values in L6-05 and L6-06 are appropriate. Motor was underloaded. Check application/machine status to eliminate fault. Low input voltage at R/L1, S/L2 and T/L3. Check the input circuit and increase the input power to within specifications. The acceleration time is set too short. Extend the time in C1-01 or other active accel settings used such as C1-03, C1-05, or C1-07 (time). Voltage fluctuation of the input power is too large. Check the input voltage. Cycle power to the Drive. UV2 CTL PS Undervolt Control Power Supply Undervoltage Undervoltage of the control circuit when running. External load was pulling down the Drive’s power supplies, or there was an internal short in the power/ gate Drive board. Remove all control wiring and test Drive or disconnect control terminal strip. Repair or replace the Power PCB/ Gate Drive PCB. Cycle power to the Drive. UV3 MC Answerback Soft Charge Circuit Fault The pre-charge contactor opened while the Drive was running. Contacts on the soft charge contactor were dirty and the soft charge contactor does not function mechanically. Diagnostics & Troubleshooting 6 - 9 Check the condition of the soft charge contactor. Repair or replace the Power PCB/ Gate Drive PCB. Alarm Detection Alarms are Drive protection functions that do not operate the fault contact. The Drive will automatically return to its original status once the cause of the alarm has been removed. During an alarm condition, the Digital Operator display flashes and an alarm output is generated at the multi-function outputs (H2-01 to H2-03) if programmed. When an alarm occurs, take appropriate corrective action according to the table below. Table 6.2 Alarm Displays and Processing Digital Operator Display AEr SI-T Address Err <3021> Description SI-T Station Number Setting Error Station number of SI-T option board was outside the setting range. Cause Corrective Action Station number setting error Check the station number setting. Refer to SI-T manual for details. Circuit of SI-T option board is faulty. Check the communications devices and signals. Refer to SI-T manual for details. BUS Option Com Err (Flashing) Option Communication Error After initial communication is established, the connection was lost. Connection is broken, master controller has stopped communicating. Check all connections, verify all user side software configurations. CALL SI-F/G ComCall (Flashing) Serial communication transmission error. Communication has not yet been established. Connection was not made properly, or user software was not configured to the proper baud rate or configuration. Check all connections, verify all user side software configurations. Normal communication was not possible for 2 seconds or longer after control data was received. Check the communications devices and signals. Communications cycle of SI-T option board set in the master controller was out of range. Check the communication cycle of SI-T option board set in master controller. Refer to SI-T manual for details. The load was locked. Reduce the load. The acceleration time and deceleration times were too short. Lengthen the acceleration and deceleration times. The load was too large. Check the mechanical system. The settings in F1-10 and F1-11 were not appropriate. Check the settings in F1-10 and F1-11. Detected when a multi-function digital input (H1-01 to H1-06) is programmed for 6A: Drive enable. The Drive does not have the enable command when the run command is applied. This alarm stops the motor. Enable command was lost while Drive was running. Check the input terminal programmed for enable command. The Run command was applied prior to the enable signal. Apply and maintain the enable command before applying the run command. Both the forward and the reverse run commands are input simultaneously for 500ms or more. This alarm stops the motor. An external forward and reverse command were input simultaneously. Check external sequence logic, so only one input is received at a time. CE Modbus Communications Error MEMOBUS Com Err Enabled when H5-05 = 1 and H5-04 = 3. (Flashing) CyC SI-T Cycle Err <3021> DEV Speed Deviation (Flashing) DNE Drive not Enable (Flashing) EF External Fault SI-T Communications Cycle Setting Error Communications cycle of SI-T option board was out of range. Excessive Speed Deviation Detected when F1-04 = 3 and A1-02 = 1 or 3. The speed deviation is greater than the setting in F1-10 for longer than the setting in F1-11. Diagnostics & Troubleshooting 6 - 10 Table 6.2 Alarm Displays and Processing Digital Operator Display EF0 Opt External Flt (Flashing) Description Cause Corrective Action Check for an external condition. Communication Option Card External Fault An external fault condition was present. Verify the parameters. Verify communication signal. EF3 Ext Fault S3 (Flashing) EF4 Ext Fault S4 (Flashing) EF5 Ext Fault S5 (Flashing) EF6 Ext Fault S6 (Flashing) External Fault at Terminal S3 - S8 Detected when terminals S3 - S8 (H1-01 to H1-06) are programmed for external fault function that alarms only and continues to run the Drive. An external fault condition exists that was connected to a multi-function digital input. Eliminate the cause of an external fault condition. SI-T Watchdog Error Detected A watchdog error was detected when the Run Command or a frequency reference was set from the option board and continuous operation was set for the E5 operation selection. Synchronization error between the master controller and the Drive for control data. Check the communication timing (such as communications cycle, etc.). Refer to SI-T manual for details. EF7 Ext Fault S7 (Flashing) EF8 Ext Fault S8 (Flashing) E5 SI-T WDT Err <3021> Check the communications signals. E-15 SI-F/G Com Err SI-F/G Communications Error Detected A communication error is detected when a run command or frequency reference is set from the SI-F/G Option Card (b1-01=3, b1-02=3) and communication is lost. Communication has been lost to the SI-F/G option card connected and b1-01=3 and/or b1-02=3. Check the settings of b1-01 and b1-02. Check the setting of F6-01. Check the host side (master) communication configuration. FAN Cooling FAN Err <3021> Drive’s Cooling Fan Fault The Drive’s cooling fan has A cooling fan fault was detected. stopped. This fault is detected when L8-32 is set to 0. Diagnostics & Troubleshooting 6 - 11 Replace the cooling fan. Table 6.2 Alarm Displays and Processing (continued) Digital Operator Display FBL Feedback Loss OH Heatsnk Overtemp (Flashing) OH2 Over Heat 2 (Flashing) Description Cause PID Feedback Loss This alarm occurs when PID Feedback Loss Detection is programmed to alarm (b5-12 = 1) and the PID feedback < PID feedback loss detection level (b5-13) for the PID feedback loss detection time (b5-14). PID Feedback source (e.g. transducer, sensor, building automation signal) was not installed correctly or was not working. Cooling Fin/Cooling Fin Fan Overheat The temperature of the Drive’s heatsink exceeded the temperature programmed in parameter L8-02. Enabled when L8-03=3. Cooling fan(s) were not working, high ambient temperature, a heat source in close proximity to Drive present, or dirty heatsink. Drive overheat alarm signal is input from a multi-function digital input terminal S3-S8 (H1-01 to H1-06) that is programmed for B: overheat alarm. An external overheat condition exists that was connected to one of the multi-function input terminals S3 - S8. Corrective Action Verify Drive is programmed to receive the PID Feedback source signal. Check to ensure the PID Feedback source is installed and working properly. Check for dirt build-up on the fans and cooling fins. Reduce the ambient temperature around the Drive. Remove the heating unit. Check for an external condition. Verify the program parameters H1-01 thru H1-06. Recheck the cycle time and the size of the load. OH3 Motor Overheat 1 (Flashing) Motor Overheating Alarm Detected when A2 or A3, programmed for motor temperature (H3-09 or H3-05 = E), exceeds 1.17V for time L1-05 and L1-03 = 3. Overheating of the motor as measured by the motor thermistor. Recheck the accel/decel time (C1-01 and C1-02). Recheck the V/F pattern (E1-01 thru E1-13). Recheck the motor rated current value (E2-01). OL3 Overtorque Det 1 (Flashing) Overtorque Detection 1 Drive output current > L6-02 for more than the time set in L6-03 and L6-01 = 1 or 2. OL4 Overtorque Det 2 (Flashing) Overtorque Detection 2 Drive output current > L6-05 for more than the time set in L6-06 and L6-04 = 1 or 2. OS Overspeed Det (Flashing) Overspeed The motor speed feedback (U1-05) exceeded the value set in F1-08 for a time longer than the setting in F1-09. Detected when A1-02 = 1 or 3 and F1-03 = 3. Ensure the values in L6-02 and L6-03 are appropriate. Motor was overloaded. Check application/machine status to eliminate fault. Ensure the values in L6-05 and L6-06 are appropriate. Motor was overloaded. Check application/machine status to eliminate fault. Overshooting/Undershooting was occurring. Adjust the ASR settings in the C5 parameter group. The reference was too high. Check the reference circuit and reference gain. The settings in F1-08 and F1-09 were not appropriate. Check the settings in F1-08 and F1-09. Diagnostics & Troubleshooting 6 - 12 Table 6.2 Alarm Displays and Processing (continued) Digital Operator Display OV DC Bus Overvolt (Flashing) PGO PG Open (Flashing) Description DC Bus Overvoltage The DC bus voltage has exceeded the trip point. Default: 208-240Vac: Trip point is 410Vdc 480Vac: Trip point is 820Vdc Detected when the Drive is in a stopped condition. E1-01 affects the trip level. PG Disconnection (Detection with Software) Detected when F1-02 = 3 and A1-02 = 1 or 3. Detected when no PG (encoder) pulses are received for a time longer than the setting in F1-14. PG Disconnection (Detection with Hardware) PGO H Detected when F1-02 = 3 and F1-25 = 1 PG Open Hardware (PG-T2 or PG-Z2) and / or F1-26 = 1 <3021> (PG-Z2) and A1-02 = 1 or 3. Detected when no PG (encoder) pulses are received. UL3 Undertorq Det 1 (Flashing) Undertorque Detection 1 Drive output current < L6-02 for more than the time set in L6-03 when L6-01 = 5 or 6. UL4 Undertorq Det 2 (Flashing) Undertorque Detection 2 Drive output current < L6-05 for more than the time set in L6-06 when L6-04 = 5 or 6. UV DC Bus Undervolt (Flashing) DC Bus Undervoltage The DC bus voltage is ≤ L2-05. Default: 208-240Vac: Trip point is 190Vdc 480Vac: Trip point is 380Vdc Detected while Drive is in a stopped condition. Cause Corrective Action High input voltage at R/L1, S/L2 and T/L3 Check the input circuit and reduce the input power to within specifications. The deceleration time is set too short. Extend the time in C1-02 or other active decel settings used such as C1-04, C1-06, C1-08 or C1-09 (time). Power factor correction capacitors are being used on the input or output to the Drive. Remove the power factor correction capacitors. There was a break in the PG wiring. Fix the broken / disconnected wiring. The PG was wired incorrectly. Fix the wiring. Power wasn’t being supplied to the PG. Supply power to the PG properly. Brake mechanism is possibly engaged. Check for open circuit when using brake (motor). There was a break in the PG wiring. Fix the broken / disconnected wiring. The PG was wired incorrectly. Fix the wiring. Power wasn’t being supplied to the PG. Supply power to the PG properly. Brake mechanism is possibly engaged Check for open circuit when using brake (motor). Ensure the values in L6-02 and L6-03 are appropriate. Motor was underloaded. Check application/machine status to eliminate fault. Ensure the values in L6-05 and L6-06 are appropriate. Motor was underloaded. Check application/machine status to eliminate fault. Low input voltage was at R/L1, S/L2 and T/L3. Check the input circuit and increase the input power to within specifications. The acceleration time was set too short. Extend the time in C1-01 or other active accel settings used such as C1-03, C1-05, or C1-07 (time). Voltage fluctuation of the input power was too large. Check the input voltage. Diagnostics & Troubleshooting 6 - 13 Table 6.2 Alarm Displays and Processing (continued) Digital Operator Display Description Cause Corrective Action Cycle power to the Drive. UV2 CTL PS Undervolt Control Power Supply Undervoltage Undervoltage of the control circuit when running. External load was pulling down the Drive’s power supplies, or there was an internal short in the power/gate Drive board. Repair or replace the Power PCB/ Gate Drive PCB. Remove all control wiring and test Drive. Cycle power to the Drive. UV3 MC Answerback Soft Charge Circuit Fault The pre-charge contactor opened while the Drive was running. Contacts on the soft charge contactor were dirty and the soft charge contactor does not function mechanically. Diagnostics & Troubleshooting 6 - 14 Check the condition of the soft charge contactor. Repair or replace the Power PCB/ Gate Drive PCB. Operator Programming Errors (OPE) An Operator Programming Error (OPE) occurs when an inapplicable parameter is set or an individual parameter setting is inappropriate. The Drive will not operate until the parameter is set correctly; however, no alarm or fault outputs will occur. If an OPE occurs, change the appropriate parameter by checking the cause shown in Table 6.3. When OPE error is displayed, press the ENTER key to display U1-34 (OPE fault constant). This monitor will display the parameter that is causing the OPE error. Table 6.3 OPE Error Displays Digital Operator Display Cause Corrective Action Drive kVA Setting Error The control board was replaced and the kVA parameter is set incorrectly. Enter the correct kVA setting (o2-04) by referring to the Drive model number in Appendix B - Table B.1. Parameter Setting Out of Range Parameter setting was outside of the allowable range. In some cases, parameter range may depend on other parameter settings. For example, when E2-03 ≥ E2-01. Verify the parameter settings. OPE03 Terminal Multi-function Input Selection Error Duplicate functions were selected, up/down commands or trim control increase/decrease were not set simultaneously. Speed search from maximum frequency and set frequency were set simultaneously. PID is enabled and up input is programmed. More than one of the speed search inputs were set simultaneously, or HSB and KEB functions were set simultaneously. N.O. and N.C. fast stop are both set, or Drive enable and DC injection input are both set. Verify parameter settings (H1-01 to H1-06). OPE05 Sequence Select Run Command Selection Error The run command selection parameter b1-02 is set to 3 but no option board is installed. Serial communication or other option board is not installed, or is installed incorrectly. Verify that the option board is installed. Remove power to the Drive and connect the option board once more. Control Method Selection Error Control method with PG feedback was selected A1-02 = 1 or 3, but a PG option board is not installed, or is installed incorrectly. Verify the control method in A1-02 and/or the installation of the PG option board. Multi-function Analog Input Error Duplicate functions were selected for the analog inputs (A2 and A3) or for either of the analog inputs (A2 or A3) and the pulse input (RP) selection. H3-09 = B and H6-01 = 1 H3-09 = C and H6-01 = 2 b1-01 (Reference Selection) was set to 4 (pulse input), and H6-01 (Pulse Train Input) was set to a value other than 0 (frequency reference). Check parameters b1-01, H3-05, H3-09, and H6-01 and correct the errors. OPE01 kVA Selection OPE02 Limit OPE06 PG Opt Missing OPE07 Analog Selection Description Diagnostics & Troubleshooting 6 - 15 Table 6.3 OPE Error Displays (continued) Digital Operator Display Description OPE08 Function Selection Error Constant Selection OPE09 PID Selection OPE10 V/F Ptrn Setting PID Control Setup Error Cause Corrective Action A setting has been made that was not applicable in the current control method. Example: a function used only in open-loop vector control was selected while in V/F control. Verify the control method and the function in question. The following settings have been made at the same time: b5-01 (PID Control Method Selection) has been set to a value other than 0. b5-15 (PID Sleep Function Start Level) has been set to a value other than 0. b1-03 (Stopping Method Selection) was set to 2 or 3. Check parameters b5-01, b5-15, and b1-03 and correct the error. V/F parameter settings were out of range. V/F Parameter Setting Error A minimum frequency value is set higher than the maximum frequency. Check parameters (E1-04 ~ E1-11). Carrier Frequency Parameter Setting Error occurs when: C6-05 > 6 and C6-04 > C6-03 OPE11 CarrFrq/On-Delay or Parameter setting was incorrect. C6-01 = 0 and C6-02 = 0,1 Check the parameter settings and correct the errors. or C6-01 = 1 and C6-02 = 0 thru 6, F ERR EEPROM R/W Err End - 3 Data Invalid Cycle power to the Drive. EEPROM Write Error The NV-RAM data does not match the EEPROM data. Power supply is turned OFF. Data Invalid Rated current set value is set too high Do a factory initialization (A1-03). Diagnostics & Troubleshooting 6 - 16 Check input data (especially, motor output current and motor rated current value). Auto-Tuning Faults Auto-Tuning faults are shown below. When the following faults are detected, the fault is displayed on the Digital Operator and the motor coasts to a stop. No fault or alarm outputs will occur. Table 6.4 Auto-Tuning Fault Displays and Processing Digital Operator Display Er - 01 Fault Er - 02 Minor Fault Description Probable Cause •There is an error in the data input for Auto-Tuning. •There is an error in the relationship between the motor output and the motor rated current. •There is an error between the noload current setting and the input motor rated current (when AutoTuning only line-to-line resistance is performed for vector control). Motor Data Fault Corrective Action • Check Auto-Tuning input data (T1 parameters). • Check Drive and motor capacity for compatibility. • Check motor rated current and no-load current (E2-03 and T1-04). • Check Auto-Tuning input data (T1 parameters). • Check output/motor wiring. • Check the load. Alarm An alarm is detected during AutoTuning. Er - 03 STOP key STOP Key Input The STOP key is pressed during Auto-Tuning, and the Auto-Tuning is interrupted. – Er - 04 Resistance Line-to-Line Resistance Fault Auto-Tuning is not completed within the specified time. The Auto-Tuning result is outside the parameter setting range. • Check Auto-Tuning input data (T1 parameters). • Check motor wiring. • If the motor and the machine are connected, disconnect the motor from the machine. • For Er-08, if the setting of T1-03 is higher than the Drive’s input voltage, change the input voltage setting. The motor did not accelerate in the specified time (C1-01 + 10 seconds). • Increase C1-01 (Accel Time 1) • Increase L7-01 and L7-02 (Forward/Reverse Torque Limits) if they are low. • If the motor and load are connected, disconnect the motor from the load. The torque reference exceeded 100% during acceleration. Detected when A1-02 = 2 or 3 (vector control). • Increase C1-01 (Accel Time 1) • Check the input data [particularly the number of PG pulses (F1-01) and the number of motor poles (E2-04)]. • If the motor and load are connected, disconnect the motor from the load. Er - 05 No-Load Current Er - 08 Rated Slip Er - 09 Accelerate Er - 11 Motor Speed No-Load Current Fault Rated Slip Fault Acceleration Fault Detected only for rotational AutoTuning. Motor Speed Fault Detected only for rotational AutoTuning. Diagnostics & Troubleshooting 6 - 17 Table 6.4 Auto-Tuning Fault Displays and Processing (continued) Digital Operator Display Description Probable Cause Corrective Action Current Detection Fault •Current exceeded the motor rated current. •Any of U/TI, V/T2, and W/T3 has open-phase. • Check that the motor is unloaded (uncoupled and brake is released). • Check Drive wiring and mounting. • Check the motor connections for continuity (on Drive output terminals and in motor junction box). Er - 13 Leakage Inductance Fault Leakage Inductance Fault Auto-Tuning did not finish within the set time. Auto-Tuning result is outside the parameter setting range. • Check Auto-Tuning input data (T1 parameters). • Check motor wiring for proper connection configuration. End - 1 V/F Over Setting V/F Settings Alarm Displayed after Auto-Tuning is complete. The torque reference exceeded 100%, and the no-load current exceeded 70% during Auto-Tuning. • Check and correct the motor settings (T1 parameters). • If the motor is coupled to the load, disconnect the motor from the load. End - 2 Saturation Motor Core Saturation Fault Detected only for rotational Auto-Tuning. During Auto-Tuning, the measured values of motor iron-core saturation coefficient 1 and 2 (E2-07 and E2-08) exceeded its setting range. A temporary value was set: E2-07 = 0.75, E2-08 = 0.50. • Check Auto-Tuning input data (T1 parameters). • Check the motor wiring. • If the motor and the load are connected, disconnect the motor from the load. End - 3 Rated FLA Alm Rated Current Setting Alarm Displayed after Auto-Tuning is complete. During Auto-Tuning, the measured value of motor rated current (E2-01) was greater than the set value. • Check the motor rated current value (E2-01). Slip Lower Limit Adjusted slip value fell below the lower limit. During stationary Auto-Tuning, the slip value has fallen to 0.2 Hz or below. • Check the input data. • Perform a Rotational Auto-Tuning. if possible. If not possible, perform a stationary Auto-Tuning 2. Er - 12 I-det. Circuit End - 4 Slip Lower Limit <3021> Diagnostics & Troubleshooting 6 - 18 Digital Operator COPY Function Faults These faults can occur during the Digital Operator COPY function. When a fault occurs, the fault content is displayed on the operator. A fault does not activate the fault contact output or alarm output. Table 6.5 Digital Operator COPY Function Faults Function READ Function Digital Operator Display Probable Causes Corrective Action PRE READ IMPOSSIBLE o3-01 was set to 1 to write parameters when the Digital Operator was write-protected (o3-02 = 0). Set o3-02 to 1 to enable writing parameters into the Digital Operator. IFE READ DATA ERROR The data file read from the Drive was of the wrong size indicating corrupted data. • Retry the Read (o3-01=1). • Check the Digital Operator cable. • Replace Digital Operator. Low Drive voltage has been detected. Check the Drive’s main incoming voltage and verify control wiring is correct. An attempted write of the Drive data to the Digital Operator’s EEPROM failed. • Repeat the read. • Replace Digital Operator. CPE ID UNMATCHED The Drive type or software number was different than the stored data in the Digital Operator. Use stored data for the F7 Drive and software number (U1-14). VAE INV. KVA UNMATCH The capacity of the Drive and the capacity of the stored data are different. Use stored data for the same Drive capacity (o2-04). RDE DATA ERROR COPY Function The control method of the Drive and the CRE control method of the stored data in the CONTROL UNMATCHED Digital Operator were different. CYE COPY ERROR CSE SUM CHECK ERROR Verify Function VYE VERIFY ERROR Use stored data for the same control method (A1-02). A parameter setting written to the Drive was different than the setting stored in the Digital Operator. Retry the Copy function (o3-01 = 2). Upon completion of the COPY function, the Drive’s data checksum was different than the Digital Operator’s data checksum. Retry the Copy function (o3-01 = 2). The set value of the Digital Operator and the Drive do not match. Retry the Verify function (o3-01 = 3). Diagnostics & Troubleshooting 6 - 19 Troubleshooting Due to parameter setting errors, faulty wiring, etc., the Drive and motor may not operate as expected when the system is started. If this occurs, use this section as a reference and apply the appropriate measures. If a fault or alarm is displayed on the Digital Operator, refer to Table 6.1 and Table 6.2. If A Parameter Cannot Be Set Use the following information if a Drive parameter cannot be set. The display does not change when the INCREASE and DECREASE keys are pressed. The following causes are possible: The Drive is operating (Drive mode). There are some parameters that cannot be set during operation. Remove the run command and then set the parameter. Parameter write enable is input. This occurs when "parameter write enable" (set value: 1B) is set for a multi-function digital input terminal (H1-01 to H1-06). If the terminal is open, the Drive parameters cannot be changed. Close the terminal and then set the parameters. Passwords do not match (Only when a password is set.) If the parameter A1-04 (Password) and A1-05 (Password Setting) settings are different, the parameters for the initialize mode cannot be changed. Enter the correct password in A1-04. If you cannot remember the password, display A1-05 (Password Setting) by pressing the Shift/Reset Key and the MENU Key simultaneously while in the A1-04 display. Reset the password and input the reset password in parameter A1-04. OPE01 through OPE11 is displayed. The set value for the parameter is wrong. Refer to Table 6.3 OPE Error Displays in this chapter and correct the setting. CPF00 or CPF01 is displayed. This is a Digital Operator communication error. The connection between the Digital Operator and the Drive may be faulty. Remove the Digital Operator and then re-install it. Diagnostics & Troubleshooting 6 - 20 If the Motor Does Not Operate Properly The following causes are possible: Ensure the Digital Operator is securely connected to the Drive. The motor does not operate when the RUN key on the Digital Operator is pressed. The following causes are possible: The Local/Remote mode is not selected properly. The status of the SEQ and REF REMOTE LEDs should be OFF for Local mode. Press the LOCAL/REMOTE key to switch. The Drive is not in Drive mode. If the Drive is not in Drive mode, it will remain in ready status and will not start. Press the MENU key once and then press the DATA/ENTER key. The Drive is now in Drive mode. The Speed Command is too low. If the Speed Command is set below the frequency set in E1-09 (Minimum Output Frequency), the Drive will not operate. Raise the Speed Command to at least the minimum output frequency. The motor does not operate when an external run command is input. The following causes are possible: The Drive is not in Drive mode. If the Drive is not in Drive mode, it will remain in ready status and will not start. Press the MENU key once and then press the DATA/ENTER key. The Drive is now in Drive mode. The Local/Remote mode is not selected properly. The status of the SEQ and REF REMOTE LEDs should be ON for Local mode. Press the LOCAL/REMOTE key to switch. The Speed Command is too low. If the Speed Command is set below the frequency set in E1-09 (Minimum Output Frequency), the Drive will not operate. Raise the Speed Command to at least the minimum output frequency. The motor stops during acceleration or when a load is connected. The load may be too large. The motor’s responsiveness limit may be exceeded if it is accelerated too rapidly by the Drive’s stall prevention function or automatic torque boost function. Increase the acceleration time (CI-01) or reduce the motor load. Also, consider increasing the motor size. The motor only rotates in one direction. "Reverse run prohibited" may be selected. If b1-04 (Prohibition of Reverse Operation) is set to 1 (reverse run prohibited), the Drive will not accept any reverse run commands. Diagnostics & Troubleshooting 6 - 21 If The Direction of the Motor Rotation is Reversed If the motor rotates in the wrong direction, the motor output wiring may be incorrect. When the Drive operates in the forward direction, the forward direction of the motor will depend on the manufacturer and the motor type, so be sure to check the motor specification. The direction of motor rotation can be reversed by switching any two wires among U/TI, V/T2, and W/T3. If using an encoder, the polarity will also have to be switched. If the Motor Stalls or Acceleration is Slow The following causes are possible: The stall prevention level during acceleration is too low. If the value set for L3-02 (Stall Prevention Acceleration Level) is set too low, the acceleration time will be increased. Check that the set value is suitable and that the load is not too large for the motor. The stall prevention level during running is too low. If the value set for L3-06 (Stall Prevention Level during Running) is too low, the motor speed and torque will be limited. Check that the values set are suitable. If the Motor Operates at a Higher Speed Than the Speed Command The following causes are possible: PID is enabled. If the PID mode is enabled (b5-01 = 1 to 4), the Drive output frequency will change to regulate the process variable to the desired setpoint. The PID can command a speed up to maximum output frequency (E1-04). If There is Low Speed Control Accuracy Above Base Speed in Open-loop Vector Control Method The Drive’s maximum output voltage is determined by its input voltage (For example, if 230Vac is input, then the maximum output voltage will be 230Vac). Vector control uses voltage to control the currents within the motor. If the vector control voltage reference value exceeds the Drive output voltage capability, the speed control accuracy will decrease because the motor currents cannot be properly controlled. Use a motor with a low rated voltage compared to the input voltage, or change to flux vector control. Diagnostics & Troubleshooting 6 - 22 If Motor Deceleration is Slow The following causes are possible: The deceleration time is long even when a braking resistor is connected. The following causes are possible: “Stall prevention during deceleration enabled” is set. When a braking resistor is connected, set parameter L3-04 (Stall Prevention Selection During Deceleration) to 0 (disabled) or 3 (with braking resistor). When this parameter is set to 1 (enabled, factory default), the stall prevention function will interfere with the braking resistor. The deceleration time setting is too long. Check the active deceleration time setting (parameters C1-02, C1-04, C1-06, or C1-08). Motor torque is insufficient. If the parameters are correct and there is no overvoltage fault, then the motor’s power may be insufficient. Consider increasing the motor and Drive’s capacity. The torque limit has been reached. When a torque limit is reached (L7-01 to L7-04), the motor torque will be limited. This can cause the deceleration time to be extended. Check to be sure that the value set for the torque limit is suitable. If a torque limit has been set for the multi-function analog input terminals A2 or A3, parameters H3-09 or H3-05 (set value: 10, 11, 12, or 15), check to be sure that the analog input value is suitable. If the Vertical-axis Load Drops (Droops) When a Mechanical Brake is Applied The brake sequence is incorrect. To ensure that the brake holds, set frequency detection 2 (H2-01 = 5) for the multi-function contact output terminals (M1 and M2) so that the contacts will turn OFF when the output frequency is greater than L4-01 (3.0 to 5.0Hz). (The contacts will turn ON below L4-01). There is a hysteresis in the frequency detection 2 function (i.e., a frequency detection width, L4-02 = 2.0Hz). Change the setting to approximately 0.5Hz if there is a load droop during stop. Do not use the multi-function contact output run signal (H2-01 = 0) for the brake ON / OFF signal. Diagnostics & Troubleshooting 6 - 23 If the Motor Overheats The following causes are possible: The load is too large. If the motor load is too large and the torque exceeds the motor's rated torque, the motor may overheat. Reduce the load amount by either reducing the load or increasing the acceleration/deceleration times. Also consider increasing the motor size. The ambient temperature is too high. The motor rating is determined by a particular ambient operating temperature range. The motor will overheat if it is run continuously at the rated torque in an environment where the maximum ambient operating temperature rating is exceeded. Lower the motor's ambient temperature to within its acceptable range. Auto-Tuning has not been performed for Vector Control Vector Control may not perform optimally if Auto-Tuning has not been performed. Therefore, perform Auto-Tuning. Alternatively, change the Control Method Selection (A1-02) to V/F Control (0 or 1). If Peripheral Devices Like PLCs or Others are Influenced by Starting or Running Drive The following solutions are possible: 1. Change the Drive's Carrier Frequency Selection (C6-02) to lower the carrier frequency. This will help to reduce the amount of transistor switching noise. 2. Install an Input Noise Filter at the Drive's input power terminals. 3. Install an Output Noise Filter at the Drive's motor terminals. 4. Use conduit. Electrical noise can be shielded by metal, so run the Drive’s power leads in a conduit or shielded cable. 5. Ground the Drive and motor. 6. Separate main circuit wiring from control wiring. Diagnostics & Troubleshooting 6 - 24 If the Ground Fault Interrupter Operates When the Drive is Run The Drive’s output is a series of high frequency pulses (PWM), so there is a certain amount of leakage current. This may cause the ground fault interrupter to operate and cut off the power supply. Change to a ground fault interrupter with a higher leakage current detection level (i.e., a sensitivity current of 200mA or greater per Unit, with an operating time of 0.1s or more), or one that incorporates high frequency countermeasures (i.e., one designed for use with a Drive). It will also help to change the Drive's Carrier Frequency Selection (C6-02) to lower the carrier frequency. In addition, remember that the leakage current increases as the cable is lengthened. If There is Mechanical Vibration Use the following information when there is mechanical vibration. The application is making unusual sounds. The following causes are possible: There may be resonance between the mechanical system's natural frequency and the carrier frequency. This is characterized by the motor running with no noise generation, but the machinery vibrates with a high-pitched whine. To prevent this type of resonance, adjust the carrier frequency with parameters C6-02 to C6-05. There may be resonance between the mechanical system’s natural frequency and the output frequency of the Drive. To prevent this from occurring, use the jump frequency function in parameters d3-01 to d3-04, or have the driven motor and load balanced to reduce vibration. Oscillation and hunting occur with V/F control. The torque compensation parameter settings may be incorrect for the machine. Adjust parameters C4-01 (Torque Compensation Gain), C4-02 (Torque Compensation Primary Delay Time Parameter), n1-02 (Hunting Prevention Gain), C2-01 (S-curve Characteristic Time at Acceleration Start), and C3-02 (Slip Compensation Primary Delay Time) in order. Lower the gain parameters and raise the primary delay time parameters. Oscillation and hunting occur with V/F w/PG control. The Speed Control Loop Gain ASR) parameter setting (C5-01) may be incorrect for the machine. Change the gain to a more effective level. If the oscillation cannot be eliminated in this way, set the Hunting Prevention Selection n1-01 = 0 (disabled). Then try re-adjusting the gain. Oscillation and hunting occur with Open-Loop Vector control. The torque compensation parameter settings may be incorrect for the machine. Adjust parameters C4-01 (Torque Compensation Gain), C4-02 (Torque Compensation Primary Delay Time Parameter), C2-01 (S-curve Characteristic Time at Acceleration Start), and C3-02 (Slip Compensation Primary Delay Time) in order. Lower the gain parameters and raise the primary delay time parameters. Vector Control may not perform optimally if Auto-Tuning has not been performed. Therefore, perform Auto-Tuning. Alternatively, change the Control Method Selection (A1-02) to V/F Control (0 or 1). Diagnostics & Troubleshooting 6 - 25 Oscillation and hunting occur with Flux Vector control. The gain adjustment may be insufficient. Adjust the speed control loop (ASR) gain (C5-01). If the oscillation points overlap with those of the machine and cannot be eliminated, increase the ASR primary time delay constant (C5-06), and then readjust the ASR gain (C5-01). Vector Control may not perform optimally if Auto-Tuning has not been performed. Therefore, perform Auto-Tuning. Alternatively, change the Control Method Selection (A1-02) to V/F Control (0 or 1). Oscillation and hunting occur with PID control. If there is oscillation or hunting during PID control, check the oscillation cycle and individually adjust the P, I, and D parameters. • Disable Integral (I) and Derivative time (D) control. • Reduce the proportional gain (P) until hunting stops. • Reintroduce the integral function, starting with long integral time values, to eliminate the P offset. • Reintroduce the derivative time and adjust with small increments to eliminate oscillation. Diagnostics & Troubleshooting 6 - 26 If the Motor Rotates Even When Drive Output is Stopped If the motor rotates even when the Drive is stopped due to a large internal load, DC-injection braking may be necessary. Adjust the DC injection braking as follows: • Increase parameter b2-04 (DC Injection Braking (initial excitation) Time at Stop). • Increase parameter b2-02 (DC Injection Braking Current). If Output Frequency Does Not Rise to the Frequency Reference Use the following information if the output frequency does not match the frequency reference. The frequency reference is within the jump frequency range. When the jump frequency function is used, the output frequency does not change within the jump frequency range. Check to be sure that the Jump Frequency (d3-01 to d3-03) and Jump Frequency Width (d3-04) settings are suitable. The frequency reference upper limit has been reached. The output frequency upper limit is determined by the following formula: Freq Ref Upper Limit = Maximum Output Frequency (E1-04) × Frequency Reference Upper Limit (d2-01) / 100 Check to be sure that the parameter E1-04 and d2-01 settings are suitable. Diagnostics & Troubleshooting 6 - 27 Main Circuit Test Procedure Before attempting any troubleshooting checks, make sure that the three-phase power is disconnected and locked out. With power removed from the unit, the DC bus capacitors will stay charged for several minutes. The Charge LED in the Drive will glow red until the DC bus voltage is below 10Vdc. To ensure that the DC bus is completely discharged, measure between the positive and negative bus with a DC voltmeter set to the highest scale. Table 6.6 Main Circuit Test Procedure Check Measure DC Bus Voltage Input Diodes (D1-D12 or Q1) Procedure 1. Set the digital multi-meter to its highest Vdc scale. 2. Measure between ⊕ 1 and (-) for the following check: Place the positive (red) meter lead on ⊕ 1. Place the negative (black) meter lead on (-). 3. If the measured voltage is < 10Vdc, it is safe to work inside the Drive. If not, wait until the DC Bus has completely discharged. The input diodes rectify or transform the three-phase input AC voltage into a DC voltage. 1. Set a digital multi-meter to the Diode Check setting. 2. Place the positive (red) meter lead on terminal R/L1. Place the negative (black) meter lead on terminal ⊕ 1. Expected reading is about 0.5Vdc. 3. Place the positive (red) meter lead on terminal S/L2. Place the negative (black) meter lead on terminal ⊕ 1. Expected reading is about 0.5Vdc. 4. Place the positive (red) meter lead on terminal T/L3. Place the negative (black) meter lead on terminal ⊕ 1. Expected reading is about 0.5Vdc. 5. Place the positive (red) meter lead on terminal R/L1. Place the negative (black) meter lead on terminal (-). Expected reading is OL displayed. 6. Place the positive (red) meter lead on terminal S/L2. Place the negative (black) meter lead on terminal (-). Expected reading is OL displayed. 7. Place the positive (red) meter lead on terminal T/L3. Place the negative (black) meter lead on terminal (-). Expected reading is OL displayed. 8. Place the positive (red) meter lead on terminal (-). Place the negative (black) meter lead on terminal R/L1. Expected reading is about 0.5Vdc. 9. Place the positive (red) meter lead on terminal (-). Place the negative (black) meter lead on terminal S/L2. Expected reading is about 0.5Vdc. 10. Place the positive (red) meter lead on terminal (-). Place the negative (black) meter lead on terminal T/L3. Expected reading is about 0.5Vdc. 11. Place the positive (red) meter lead on terminal ⊕ 1. Place the negative (black) meter lead on terminal R/L1. Expected reading is OL displayed. Diagnostics & Troubleshooting 6 - 28 Table 6.6 Main Circuit Test Procedure (continued) Check Input Diodes (D1-D12 or Q1) Procedure 12. Place the positive (red) meter lead on terminal ⊕ 1. Place the negative (black) meter lead on terminal S/L2. Expected reading is OL displayed. 13. Place the positive (red) meter lead on terminal ⊕ 1. Place the negative (black) meter lead on terminal T/L3. Expected reading is OL displayed. The soft charge resistor works in conjunction with the soft charge contactor to slowly charge the DC bus capacitors to minimize the inrush current when power is applied to the Drive. Soft Charge Resistor Check (R1, R2, 6PCB) 1. Conduct a visual inspection. Check for physical damage. 2. Set a digital multi-meter to the R x 1 scale. 3. If the resistor is damaged, the measured value will be infinite Ω. The purpose of the soft charge contactor is to bypass the soft charge resistor after the DC bus voltage has reached its normal operating level. 1. 2. 3. 4. Soft Charge Contactor (K1) 5. 6. 7. 8. DC Bus Fuse (F1) Conduct a visual inspection. Check for physical damage. Set a digital multi-meter to the R x 1 scale. On Drives with a board-mounted contactor, verify that each contact resistance measures infinite Ω. On Drives without a board-mounted contactor, press the plunger in, and verify that each contact measures 0Ω. On Drives without a board-mounted contactor, release the plunger, and verify that the resistance is the ohmic value of the soft charge resistor. On Drives with a board-mounted contactor, verify that the contactor coil measures about 300Ω. The coil can be tested by applying the appropriate voltage to verify the contacts change states. On Drives without a board-mounted contactor, verify that the 230Vac contactor coil measures about 175Ω. The coil can be tested by applying the appropriate voltage to verify the contacts change states. On Drives without a board-mounted contactor, verify that the 24Vdc auxiliary coil measures about 2.2MΩ. The coil can be tested by applying the appropriate voltage to verify the contacts change states. The DC bus fuse is located in the negative portion of the DC Bus. The DC bus fuse is used to protect the main circuit components if the output transistors short. If the DC bus fuse is open, at least one of the output transistors has failed. When a transistor fails, there is a short between the positive and negative portions of the DC Bus. The DC bus fuse does not protect the transistors, but protects the rest of the main circuit from the high current present during a short. Never replace the DC bus fuse without first checking all of the output transistors. 1. Set a digital multi-meter to the R x 1 scale. 2. Place one lead of the multi-meter on one side of the fuse and place the other lead of the multimeter on the other side of the fuse. 3. If the fuse is good, the measured value will be 0Ω. If the fuse is bad, the measured value will be infinite Ω. Diagnostics & Troubleshooting 6 - 29 Table 6.6 Main Circuit Test Procedure (continued) Check Procedure Output Transistors (Q1-Q12) The output transistors are used to switch the DC bus voltage to allow current to flow to the motor. The following checks will read erroneously if the DC bus fuse is open. 1. Set a digital multi-meter to the Diode Check setting. 2. Place the positive (red) meter lead on terminal U/T1. Place the negative (black) meter lead on terminal ⊕ 1. Expected reading is about 0.5Vdc. 3. Place the positive (red) meter lead on terminal V/T2. Place the negative (black) meter lead on terminal ⊕ 1. Expected reading is about 0.5Vdc. 4. Place the positive (red) meter lead on terminal W/T3. Place the negative (black) meter lead on terminal ⊕ 1. Expected reading is about 0.5Vdc. 5. Place the positive (red) meter lead on terminal U/T1. Place the negative (black) meter lead on terminal (-). Expected reading is OL displayed. 6. Place the positive (red) meter lead on terminal V/T2. Place the negative (black) meter lead on terminal (-). Expected reading is OL displayed. 7. Place the positive (red) meter lead on terminal W/T3. Place the negative (black) meter lead on terminal (-). Expected reading is OL displayed. 8. Place the positive (red) meter lead on terminal (-). Place the negative (black) meter lead on terminal U/T1. Expected reading is about 0.5Vdc. 9. Place the positive (red) meter lead on terminal (-). Place the negative (black) meter lead on terminal V/T2. Expected reading is about 0.5Vdc. 10. Place the positive (red) meter lead on terminal (-). Place the negative (black) meter lead on terminal W/T3. Expected reading is about 0.5Vdc. 11. Place the positive (red) meter lead on terminal ⊕ 1. Place the negative (black) meter lead on terminal U/T1. Expected reading is OL displayed. 12. Place the positive (red) meter lead on terminal ⊕ 1. Place the negative (black) meter lead on terminal V/T2. Expected reading is OL displayed. 13. Place the positive (red) meter lead on terminal ⊕1. Place the negative (black) meter lead on terminal W/T3. Expected reading is OL displayed. Control Power Fuse All Drives have a Control Power Fuse. The fuse is located on either the Power PCB (3PCB) or the Gate Drive PCB (3PCB). The Control Power Fuse protects the primary switching mode power supply. 1. Set a digital multi-meter to the R x 1 scale. 2. Place one lead of the multi-meter on one side of the fuse and place the other lead of the multimeter on the other side of the fuse. 3. If the fuse is good, the measured value will be 0Ω. If the fuse is bad, the measured value will be infinite Ω. Diagnostics & Troubleshooting 6 - 30 Table 6.6 Main Circuit Test Procedure (continued) Check Procedure 24Vdc Cooling Fans (Heat Sink & Internal) The Heat Sink & Internal Cooling Fans cool the heat sink as well as the output transistor modules of the Drive. 1. Conduct a visual inspection to ensure the fan turns freely. 2. If there is no physical evidence that the fan is bad, the fan motor can be checked with a digital multi-meter. 3. Set the digital multi-meter to the R x 1 scale. 4. Measure across the fan motor terminals. If 0Ω are measured, conclude that the fan motor is shorted. If infinite Ω are measured, conclude that the fan motor is burned open. 5. If the fan is not working, then disconnect the fan and apply 24Vdc to the fan to test the motor. 230/240Vac Cooling Fans (Heat Sink) The Heat Sink Cooling Fans cool the heat sink to remove heat from the Drive. 1. Conduct a visual inspection to ensure the fan turns freely. 2. If there is no physical evidence that the fan is bad, the motor can be checked with a digital multi-meter. 3. Set a digital multi-meter to the R x 1 scale. 4. Measure across the fan motor terminals. If the fan motor is good, the measured value should be about 500Ω. If 0Ω are measured, conclude that the fan motor is shorted. If infinite ohms are measured, conclude that the fan motor is burned open. 5. If the fan is not working, then disconnect the fan and apply 230/240Vac to the fan to test the motor. Cooling Fan Fuse Large Drive units contain a Cooling Fan Fuse. It is located on either the Gate Drive Board (3PCB) or the Tap Change Board (8PCB). If the Cooling Fan Fuse is open, then the 230/240Vac cooling fans may be defective. 1. Set a digital multi-meter to the R x 1 scale. 2. Place one lead of the multi-meter on one side of the fuse and place the other lead of the multimeter on the other side of the fuse. 3. If the fuse is good, the measured value will be 0Ω. If the fuse is bad, the measured value will be infinite Ω. Drive Date Stamp Information This information is used to determine when a Drive was built to see if it is within its warranty period. The date stamp is located on the lower right side of the Drive. YEA Production PRD 00.7.22 96 3. 31 Manufacture Date INSP2 Inspector Number Fig 6.1 Date Stamp Location Diagnostics & Troubleshooting 6 - 31 Notes: Diagnostics & Troubleshooting 6 - 32 Chapter 7 Maintenance This chapter describes basic maintenance and inspection of the Drive. Please refer to these instructions to ensure that the Drive receives the proper maintenance to maintain overall performance. Periodic Inspection ............................................................ 7-2 Preventive Maintenance.................................................... 7-3 Periodic Maintenance of Parts .......................................... 7-4 Heatsink Cooling Fan Replacement.................................. 7-5 Removing and Mounting the Terminal Card...................... 7-7 Maintenance 7 - 1 Periodic Inspection Check the following items during periodic maintenance. • The motor should not be vibrating or making unusual noises. • There should be no abnormal heat generation from the Drive or motor. • The ambient temperature should be within the Drive specification of -10°C to 40°C (14°F to 104°F). • The output current value shown on U1-03 should not be higher than the motor or Drive rated current for an extended period of time. • The cooling fan in the Drive should be operating normally. Before attempting any maintenance checks, make sure that the three-phase power is disconnected and locked out. With power removed from the unit, the DC bus capacitors will stay charged for several minutes. The Charge LED in the Drive will glow red until the DC bus voltage is below 10Vdc. To ensure that the DC bus is completely discharged, measure between the positive and negative bus with a DC voltmeter set to the highest scale. Be sure not to touch terminals immediately after the power has been turned off. Doing so can result in electric shock. Please refer to Warnings starting on page i. Table 7.1 Periodic Inspections With no Power Applied Item Inspection External terminals, mounting bolts, connectors, etc. Corrective Action Are all screws and bolts tight? Tighten loose screws and bolts firmly. Are connectors tight? Reconnect the loose connectors. Are the fins dirty or dusty? Clean off any dirt and dust with an air gun using clean and dry air at a pressure between 55-85 psi. Control PCB Terminal PCB Power PCB Gate Drive PCBs Is there any conductive dirt or oil mist on the PCBs? Clean off any dirt and dust with an air gun using clean and dry air at a pressure between 55-85 psi. Replace the boards if they cannot be made clean. Input Diodes IPMs Output Transistors Is there any conductive dirt or oil mist on the modules or components? Clean off any dirt and dust with an air gun using clean and dry air at a pressure between 55-85 psi. Replace the boards if they cannot be made clean. DC bus capacitors Are there any irregularities, such as discoloration or odor? Replace the capacitors or Drive. Cooling fins Apply power to the Drive and conduct the following inspection. Table 7.2 Periodic Inspections With Power Applied Item Inspection Corrective Action Cooling fan(s) Is there any abnormal noise or vibration, or has the total operating time exceeded 20,000 hours. Check U1-40 for elapsed cooling fan operation time. Replace Cooling Fan Maintenance 7 - 2 Preventive Maintenance Table 7.3 Preventive Maintenance Inspection Points Item Check Points Ambient temperature Humidity Dust Harmful gas Oil mist X X X X X Abnormal vibration or noise X AC Power Supply Main circuit & control voltage X Conductors & Wire Connections Loose lugs, screws & wires Hot spots on parts Corrosion Bent conductors Breakage, cracking or discoloration Check spacing Environment General Equipment Transformers & Reactors AC Power Circuit & Devices Every 3-6 Months Discoloration or noise Terminal Blocks Yearly X X X X X X X Loose, damaged X Leakage Ruptures, broken, expansion Capacitance & insulation resistance X X X Relays & Contactors Noisy Contact discoloration X X Soft Charge Resistors Cracked Discoloration X X Speed reference voltage/current I/O contact operation X X DC Bus Capacitors Control Circuits Operation Cooling System Cooling Fans/Fins & Heatsink Keypad/Display Digital Operator Abnormal fan noise Loose connectors Free of accumulation X LEDs Monitor display values Key functionality Clean X X If the Drive is used under the following conditions, it may be necessary to inspect more often: • High ambient temperatures, humidity or altitudes above 3,300 feet. • Frequent starting and stopping. • Fluctuations of the AC power supply or load. • Excessive vibration and/or shock loading. • Poor environment, including dust, metal dust, salt, sulfuric acid, chlorine. • Poor storage conditions. Maintenance 7 - 3 X X X X Periodic Maintenance of Parts In order to keep the Drive operating normally over a long period of time, and to prevent down time due to an unexpected failure, it is necessary to perform periodic inspections and replace parts according to their service life. The data indicated in the following table is to be used as a general guideline only. Periodic inspection standards vary depending on the Drive's installation environment conditions and usage. The Drive's suggested maintenance periods are noted below. Table 7.4 Part Replacement Guidelines Part Standard Replacement Period Replacement Method Cooling fan(s) 2 to 3 years (20,000 hours) Replace with new part. DC bus capacitors 5 years Replace with new part. (Determine need by inspection.) Soft charge contactor - Determine need by inspection. DC bus fuse Control power fuse 10 years Replace with new part. PCB capacitors 5 years Replace with new board. (Determine need by inspection.) Note: The standard replacement period is based on the following usage conditions: Ambient temperature:Yearly average of 86°F/ 30°C Load factor: 80% maximum Operating time: 12 hours maximum per day Maintenance 7 - 4 Heatsink Cooling Fan Replacement Models CIMR-F7U20P4 thru 2018 and 40P4 thru 4018 A cooling fan is attached to the bottom of the Drive. If the Drive is installed using the mounting holes on the back of the Drive, the cooling fan can be replaced without removing the Drive from the installation panel. If the Drive is mounted with the heatsink external to the enclosure, the cooling fan can only be replaced by removing the Drive from the enclosure. Removing the Heatsink Cooling Fan 1. Always turn OFF the input power before removing and installing the heatsink cooling fan. 2. Press in on the right and left sides of the fan cover in the direction of arrows “1” and then pull the fan out in the direction of arrow “2”. 3. Pull out the cable connected to the fan from the fan cover and disconnect the power connector. See Fig 7.1. 4. Open the fan cover on the left and right sides in the direction of arrows “3” and remove the fan cover from the fan. 3 3 Power Connector Fig 7.1 Cooling Fan Replacement Procedure Installing the Heatsink Cooling Fan 1. Attach the fan cover to the cooling fan. Be sure that the air flow direction indicated by the arrows above faces into the Drive. 2. Connect the power connector securely and place the power connector and cable into the fan cover. 3. Mount the fan cover on the Drive. Be sure that the tabs on the sides of the fan cover click into place on the Drive. Maintenance 7 - 5 Models CIMR-F7U2022 thru 2110 and 4030 thru 4300 These Drives have an internal cooling fan assembly and a heatsink cooling fan assembly. The heatsink cooling fan assembly is attached to the top of the heatsink inside the Drive. The cooling fan(s) can be replaced without removing the Drive from the installation panel. Removing the Heatsink Cooling Fan Assembly 1. Always turn OFF the input power before removing and installing the heatsink cooling fan assembly. 2. Remove the terminal cover, Drive cover, Digital Operator, and front cover from the front of the Drive. 3. Remove the Control PCB bracket (if necessary) to which the cards are mounted. Remove all cables connected to the Control PCB and remove the cooling fan power connector from the fan board (13 PCB) positioned near the top of the Drive. 4. Remove the cooling fan power connectors from the gate drive board (3PCB) positioned at the back of the Drive. 5. Remove the fan assembly screws and pull out the fan assembly from the Drive. 6. Remove the cooling fan(s) from the fan assembly. Mounting the Heatsink Cooling Fan Assembly After attaching a new cooling fan, reverse the above procedure to attach all of the components. When attaching the cooling fan to the mounting bracket, be sure that the air flow goes toward the top of the Drive. Air flow direction Fan cover Control PCB bracket Control PCB Connector Gate driver Fig 7.2 Cooling Fan Assembly Replacement Procedure Maintenance 7 - 6 Removing and Mounting the Terminal Card The terminal card can be removed and mounted without disconnecting the control wiring. IMPORTANT Always confirm that input power is removed and the Charge LED is not lit before removing or mounting the terminal card. Removing the Terminal Card 1. Remove the terminal cover on the Drive. 2. Remove the Digital Operator and front cover from the Drive. 3. Remove the wires connected to FE and/or NC on the terminal card. 4. Loosen the mounting screws on the left and right sides of the terminal card until they are free. It is not necessary to remove the mounting screws completely. They are captive and self-rising. 5. Pull the terminal card out in the direction of the block arrow. Mounting the Terminal Card Reverse the removal procedure to mount the terminal card. Confirm that the terminal card and the Control PCB properly meet at connector CN8 before insertion. The connector pins may be damaged if the terminal card is forced into place, possibly preventing correct Drive operation. FE NC CN8 Mounting Screw Mounting Screw Fig 7.3 Terminal Card Removal Procedure Maintenance 7 - 7 Notes: Maintenance 7 - 8 Appendix A Parameters This appendix lists all the parameter numbers and names, along with a description of each. The abbreviated name as it appears on the Digital Operator display/keypad is shown in bold type. F7 Parameter List ............................................................... A-3 F7 Monitor List .................................................................. A-38 F7 Fault Trace List............................................................ A-41 F7 Fault History List.......................................................... A-41 Parameters A - 1 Some parameters in the following tables are not available for all Control Methods (A1-02). Use the key below to determine which parameters are available for the selected Control Method. V/F V/F w/PG Open Loop Vector Flux Vector Q Q A - Q: Parameters which can be monitored and set in either Quick Setting or Advanced Programming Menu A: Parameters which can be monitored and set in only Advanced Programming Menu -: Parameters which cannot be monitored or set for the selected Control Method Parameters A - 2 F7 Parameter List Table A.1 F7 Parameter List Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0 to 6 0 A A A A Initialization A1-00 Language Selection Select Language Language selection for the Digital Operator. This parameter is not reset to the factory setting by A1-03. 0: English 1: Japanese 2: Deutsch 3: Francais 4: Italiano 5: Espanol 6: Portugues A1-01 Access Level Selection Access Level Selects which parameters are accessible via the Digital Operator. 0: Operation Only 1: User Level (only available if A2 parameters have been set) 2: Advanced Level 0 to 2 2 A A A A Control Method Selection Control Method Selects the Control Method of the Drive. 0: V/F control without PG 1: V/F control with PG 2: Open Loop Vector 3: Flux Vector (Closed Loop Vector) 0 to 3 2 Q Q Q Q A1-03 Initialize Parameters Init Parameters Used to return all parameters to their factory or user default settings. (Initializes and then returns A1-03 to zero.) 0: No Initialize 1110: User Initialize (The user must first set their own parameter values and then store them using parameter o2-03.) 2220: 2-Wire Initialization 3330: 3-Wire Initialization 0 to 3330 0 A A A A A1-04 Password 1 Enter Password 0 to 9999 0 A A A A A1-05 Password 2 Select Password 0 to 9999 0 A A A A A2-01 User Parameter 1 User Param 1 – A A A A A2-02 User Parameter 2 User Param 2 – A A A A A2-03 User Parameter 3 User Param 3 – A A A A A2-04 User Parameter 4 User Param 4 – A A A A – A A A A A1-02 When the value set into A1-04 does NOT match the value set into A1-05, parameters A1-01 thru A1-03 and A2-01 thru A2-32 cannot be changed. All other parameters as determined by A1-01 can be changed. Parameter A1-05 can be accessed by pressing the MENU key while holding the RESET key. User Parameters Selects the parameters to be available in the User Access Level (A1-01 = 1). These parameters are not related to the User Initialize function. b1-01 to o3-02 A2-05 User Parameter 5 User Param 5 A2-06 User Parameter 6 User Param 6 – A A A A A2-07 User Parameter 7 User Param 7 – A A A A A2-08 User Parameter 8 User Param 8 – A A A A A2-09 User Parameter 9 User Param 9 – A A A A Denotes that parameter can be changed when the Drive is running. Parameters A - 3 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector A2-10 User Parameter 10 User Param 10 – A A A A A2-11 User Parameter 11 User Param 11 – A A A A A2-12 User Parameter 12 User Param 12 – A A A A A2-13 User Parameter 13 User Param 13 – A A A A A2-14 User Parameter 14 User Param 14 – A A A A A2-15 User Parameter 15 User Param 15 – A A A A A2-16 User Parameter 16 User Param 16 – A A A A A2-17 User Parameter 17 User Param 17 – A A A A A2-18 User Parameter 18 User Param 18 – A A A A A2-19 User Parameter 19 User Param 19 – A A A A A2-20 User Parameter 20 User Param 20 – A A A A – A A A A Selects the parameters to be available in the User Access Level (A1-01 = 1). These parameters are not related to the User Initialize function. b1-01 to o3-02 A2-21 User Parameter 21 User Param 21 A2-22 User Parameter 22 User Param 22 – A A A A A2-23 User Parameter 23 User Param 23 – A A A A A2-24 User Parameter 24 User Param 24 – A A A A A2-25 User Parameter 25 User Param 25 – A A A A A2-26 User Parameter 26 User Param 26 – A A A A A2-27 User Parameter 27 User Param 27 – A A A A A2-28 User Parameter 28 User Param 28 – A A A A A2-29 User Parameter 29 User Param 29 – A A A A A2-30 User Parameter 30 User Param 30 – A A A A A2-31 User Parameter 31 User Param 31 – A A A A A2-32 User Parameter 32 User Param 32 – A A A A Denotes that parameter can be changed when the Drive is running. Parameters A - 4 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0 to 4 1 Q Q Q Q Sequence b1-01 Frequency Reference Selection Reference Source Selects the frequency reference input source. 0: Operator - Digital preset speed U1-01 or d1-01 to d1-17. 1: Terminals - Analog input terminal A1 (or terminal A2 based on parameter H3-09). 2: Serial Com - Modbus RS-422/485 terminals R+, R-, S+, and S-. 3: Option PCB - Option board connected on 2CN. 4: Pulse Input (Terminal RP) b1-02 Run Command Selection Run Source Selects the run command input source. 0: Operator - RUN and STOP keys on Digital Operator. 1: Terminals - Contact closure on terminals S1 or S2. 2: Serial Com - Modbus RS-422/485 terminals R+, R-, S+, and S-. 3: Option PCB - Option board connected on 2CN. 0 to 3 1 Q Q Q Q b1-03 Stopping Method Selection Stopping Method Selects the stopping method when the run command is removed. 0: Ramp to Stop 1: Coast to Stop 2: DC Injection to Stop 3: Coast with Timer (A new run command is ignored if received before the timer expires). 0 to 3 0 Q Q Q Q b1-04 Reverse Operation Selection Reverse Oper Determines the forward rotation of the motor, and if reverse operation is disabled. 0: Reverse Enabled 1: Reverse Disabled 2: Exchange Phase - Change direction of forward motor rotation. 0 to 2 0 A - (A*) A - (A*) b1-05 Minimum Output Frequency (E1-09) or Less Operation Selection Zero-Speed Oper Operation method when frequency reference is less than minimum output frequency set in E1-09. 0: Operates according to frequency reference (E1-09 is disabled) 1: Output shuts off (coast to stop if less than E1-09) 2: Operates according to E1-09 (frequency reference set to E1-09) 3: Zero speed (frequency reference of zero is less than E1-09) 0 to 3 0 - - - A b1-06 Digital Input Scan Time Cntl Input Scans Sets the scan rate of terminals S1 to S8. 0: 2ms - 2 scans (for quick response) 1: 5ms - 2 scans (for noisy environments) 0 to 1 1 A A A A b1-07 Local/Remote Run Selection LOC/REM RUN Sel 0: Cycle External RUN - If the run command is closed when switching from local mode to remote mode, the Drive will not run. 1: Accept External RUN - If the run command is closed when switching from local mode to remote mode, the Drive WILL run. 0 to 1 0 A A A A b1-08 Run Command Selection During Program RUN CMD at PRG 0: Disabled - Run command accepted only in the operation menu. 1: Enabled - Run command accepted in all menus (except when b1-02 = 0). 0 to 1 0 A A A A DC Injection Braking b2-01 DC Injection Braking Start Frequency DCInj Start Freq Sets the frequency at which DC injection braking starts when ramp to stop (b1-03 = 0) is selected. If b2-01< E1-09, DC Injection braking starts at E1-09. 0.0 to 10.0 0.5Hz A A A A b2-02 DC Injection Braking Current DCInj Current Sets the DC injection braking current as a percentage of the Drive rated current. 0 to 100 50% A A A - b2-03 DC Injection Braking Time at Start DCInj Time @Start Sets the time of DC injection braking at start in units of 0.01 seconds. 0.00 to 10.00 0.00sec A A A A b2-04 DC Injection Braking Time at Stop DCInj Time @Stop Sets the time length of DC injection braking at stop in units of 0.01 seconds. 1.When b1-03 = 2, actual DC Injection time is calculated as follows: b2-04 * 10 * Output Frequency / E1-04. 2.When b1-03 = 0, this parameter determines the amount of time DC Injection is applied to the motor at the end of the decel ramp. 3.This should be set to a minimum of 0.50 seconds when using HSB. This will activate DC injection during the final portion of HSB and help ensure that the motor stops completely. 0.00 to 10.00 0.00sec A A A A b2-08 Magnetic Flux Compensation Capacity Field Comp Sets the magnetic flux compensation as a percentage of the no-load current value (E2-03). 0 to 1000 0% - - A - Denotes that parameter can be changed when the Drive is running. * For parameter b1-04 settings 0 and 1. Parameters A - 5 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0 to 3 2 A A A - 0 to 200 120% A - A - Speed Search Enables/disables and selects the speed search function at start. b3-01 0: Speed Estimation Speed Search Disable - Speed search at start is disabled (however the estimated speed method is used for multi-function input, power loss ridethrough, auto fault retry) 1: Speed Estimation Speed Search Enable - The speed estimation method of speed search is enabled at run command. 2: Current Detection Speed Search Disable - Speed search at start is disabled (however the current detection method is used for multi-function input, power loss ride through, auto fault retry) Speed Search Selection SpdSrch at Start 3: Current Detection Speed Search Enable - The current detection method of speed search is enabled at run command. Speed Estimation Method: Motor speed and direction are measured using residual motor flux. Current Detection Method: Motor speed is measured using current feedback levels (unidirectional only). b3-02 Speed Search Deactivation Current SpdSrch Current Used only when b3-01 = 2 or 3. Sets the speed search operation current as a percentage of Drive rated current. b3-03 Speed Search Deceleration Time SpdSrch Dec Time Used only when b3-01 = 2 or 3. Sets the deceleration time during speed search. 0.1 to 10.0 2.0sec A - A - b3-05 Speed Search Delay Time Search Delay Delays the speed search operation after a momentary power loss to allow time for an external output contactor to re-energize. 0.0 to 20.0 0.2sec A A A A b3-10 Speed Search Detection Compensation Gain Srch Detect Comp Sets the gain for the frequency at which the Drive starts speed estimation speed search. Use only when b3-01 = 0 or 1. 1.00 to 1.20 1.10 A - A - b3-14 Bi-directional Speed Search Selection Bidir Search Sel This parameter enables the Drive to detect the direction of rotation of the motor during speed search. 0: Disable - Drive uses frequency reference direction. 1: Enable - Drive uses detected direction 0 to 1 1 A A A - b3-17 <3021> Speed Search Restart Current Level SrchRestart Lvl Sets the current level to retry a speed search as a percentage, taking the Drive rated current as 100%. 0 to 200 150% * A No A No b3-18 <3021> Speed Search Detection Time SrchRestart Time Sets the time for speed search detection in seconds. 0.00 to 1.00 0.10 sec A No A No b3-19 <3021> Number of Speed Search Restarts Num of SrchRestr Sets the number of times that a speed search can be restarted. 0 to 10 0 A No A No Delay Timers b4-01 Timer Function ON-Delay Time Delay-ON Timer Used in conjunction with a multi-function digital input and a multifunction digital output programmed for the timer function. This sets the amount of time between when the digital input is closed, and the digital output is energized. 0.0 to 3000.0 0.0sec A A A A b4-02 Timer Function OFF-Delay Time Delay-OFF Timer Used in conjunction with a multi-function digital input and a multifunction digital output programmed for the timer function. This sets the amount of time the output stays energized after the digital input is opened. 0.0 to 3000.0 0.0sec A A A A Denotes that parameter can be changed when the Drive is running. * For Heavy Duty (HD) Rating (C6-01=0): Factory Setting = 150% For Normal Duty (ND) Rating (C6-01=2): Factory Setting = 120%. Parameters A - 6 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector PID Function Setting PID Mode This parameter determines the function of the PID control. 0: Disabled 1: D = Feedback 2: D = Feed-Forward 3: Freq. Ref. + PID output (D = Feedback) 4: Freq. Ref. + PID output (D = Feed-Forward) 0 to 4 0 A A A A b5-02 Proportional Gain Setting PID Gain Sets the proportional gain of the PID controller. 0.00 to 25.00 1.00 A A A A b5-03 Intregral Time Setting PID I Time Sets the integral time for the PID controller. A setting of zero disables integral control. 0.0 to 360.0 1.0sec A A A A b5-04 Intregral Limit Setting PID I Limit Sets the maximum output possible from the integrator. Set as a percentage (%) of maximum frequency. 0.0 to 100.0 100.0% A A A A b5-05 Derivative Time PID D Time Sets D control derivative time. A setting of 0.00 disables derivative control. 0.00 to 10.00 0.00sec A A A A b5-06 PID Output Limit PID Limit Sets the maximum output possible from the entire PID controller. Set as a percentage (%) of maximum frequency. 0.00 to 100.0 100.0% A A A A b5-07 PID Offset Adjustment PID Offset Sets the amount of offset of the output of the PID controller. Set as a percentage (%) of maximum frequency. The offset is summed with the PID output. This can be used to artificially kick-start a slow starting PID loop. –100.0 to +100.0 0.0% A A A A PID Primary Delay Time Constant PID Delay Time Sets the amount of time for the filter on the output of the PID controller. 0.00 to 10.00 0.00sec A A A A b5-09 PID Output Level Selection Output Level Sel Determines whether the PID controller will be direct or reverse acting. 0: Normal Output 1: Reverse Output 0 to 1 0 A A A A b5-10 PID Output Gain Setting Output Gain Sets the output gain of the PID controller. 0.0 to 25.0 1.0 A A A A b5-11 PID Output Reverse Selection Output Rev Sel 0: 0 limit (when PID output goes negative, Drive stops). 0 limit is automatic when reverse prohibit is selected using b1-04. 1: Reverse (when PID goes negative, Drive reverses). 0 to 1 0 A A A A b5-12 PID Feedback Reference Missing Detection Selection Fb los Det Sel 0: Disabled 1: Alarm 2: Fault 0 to 2 0 A A A A b5-13 PID Feedback Loss Detection Level Fb los Det Lvl Sets the PID feedback loss detection level as a percentage (%) of maximum frequency (E1-04). 0 to 100 0% A A A A b5-14 PID Feedback Loss Detection Time Fb los Det Time Sets the PID feedback loss detection delay time in terms of seconds. 0.0 to 25.5 1.0sec A A A A b5-15 PID Sleep Function Start Level PID Sleep Level Sets the sleep function start frequency. Varies by Duty Rating* 0.0Hz A A A A b5-16 PID Sleep Delay Time PID Sleep Time Sets the sleep function delay time in terms of seconds. 0.0 to 25.5 0.0sec A A A A b5-17 PID Accel/Decel Time PID Acc/Dec Time Applies an accel/decel time to the PID setpoint reference. The Drive’s standard softstarter (C1-XX and S-curve) still affects the output of the PID algorithm. 0.0 to 25.5 0.0sec A A A A b5-18 PID Setpoint Selection PID Setpoint Sel Allows the b5-19 setting to be the PID target setpoint value. 0: Disabled 1: Enabled 0 to 1 0 A A A A b5-19 PID Setpoint Value PID Setpoint Sets the PID target value. Use only when b5-18 = 1 0.0 to 100.0 0.0% A A A A Description PID Control b5-01 b5-08 Denotes that parameter can be changed when the Drive is running. * For Heavy Duty (HD) Rating (C6-01=0): Setting Range=0.0 to 300.0. For Normal Duty (ND) Rating (C6-01=2): Setting Range=0.0 to 400.0. Parameters A - 7 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0.0 to 400.0 0.0Hz A A A A 0.0 to 10.0 0.0sec A A A A 0.0 to 400.0 0.0Hz A A A A 0.0 to 10.0 0.0sec A A A A Reference Hold (Dwell) b6-01 Dwell Reference at Start Dwell Ref @Start Temporarily holds the frequency reference. b6-02 Dwell Time at Start Dwell Time @Start Run command ON b6-03 Dwell Frequency at Stop Dwell Ref @Stop Output frequency b6-04 Dwell Time at Stop Dwell Time @Stop OFF b6-01 b6-02 b6-03 Time b6-04 Droop Control b7-01 Droop Control Level Droop Quantity Sets the speed decrease as a percentage of maximum output frequency (E1-04) when the motor is at 100% load torque. Setting of 0.0 disables droop control. 0.0 to 100.0 0.0% - - - A b7-02 Droop Control Delay Time Droop Delay Time Determines the droop control delay time in response to a load change. 0.03 to 2.00 0.05sec - - - A b8-01 Energy Saving Control Selection Energy Save Sel Energy Savings function enable/disable selection. 0: Disabled 1: Enabled 0 to 1 0 A A A A b8-02 Energy Saving Gain Energy Save Gain Sets energy savings control gain when in vector control method. 0.0 to 10.0 1.0 - - A A b8-03 Energy Saving Control Filter Time Constant Energy Saving F.T Sets energy saving control filter time constant when in vector control method. 0.00 to 10.00 Varies by kVA - - A A b8-04 Energy Saving Coefficient Value Energy Save COEF 0.0 to 655.00 Varies by kVA A A - - b8-05 Power Detection Filter Time kW Filter Time 0 to 2000 20ms A A - - b8-06 Search Operation Voltage Limit Search V Limit 0 to 100 0% A A - - 0 to 100 5 - - - A 0 to 16383 10 pulses - - - A Energy Saving Used to fine-tune the energy savings function when in V/F control method. Zero Servo b9-01 Zero Servo Gain Zero Servo Gain Sets the position loop gain for Zero Servo command. This function is effective when multi-function input “zero servo command” is set. b9-02 Zero Servo Completion Width Zero Servo Count Sets number of pulses used for the multi-function output of “zero servo completion”. Denotes that parameter can be changed when the Drive is running. Parameters A - 8 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Setting Range Description Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector Accel / Decel C1-01 Acceleration Time 1 Accel Time 1 Sets the time to accelerate from zero to maximum frequency. Q Q Q Q C1-02 Deceleration Time 1 Decel Time 1 Sets the time to decelerate from maximum frequency to zero. Q Q Q Q C1-03 Acceleration Time 2 Accel Time 2 Sets the time to accelerate from zero to maximum frequency when selected via a multi-function input. A A A A C1-04 Deceleration Time 2 Decel Time 2 Sets the time to decelerate from maximum frequency to zero when selected via a multi-function input. A A A A C1-05 Acceleration Time 3 Accel Time 3 Sets the time to accelerate from zero to maximum frequency when selected via a multi-function input. A A A A C1-06 Deceleration Time 3 Decel Time 3 Sets the time to decelerate from maximum frequency to zero when selected via a multi-function input. A A A A C1-07 Acceleration Time 4 Accel Time 4 Sets the time to accelerate from zero to maximum frequency when selected via a multi-function input. A A A A C1-08 Deceleration Time 4 Decel Time 4 Sets the time to decelerate from maximum frequency to zero when selected via a multi-function input. A A A A C1-09 Fast Stop Time Fast Stop Time Sets the time to decelerate from maximum frequency to zero for the multi-function input "Fast Stop" function. 0.0 to 6000.0 10.0sec A A A A C1-10 Accel/Decel Time Setting Unit Acc/Dec Units Sets the setting resolution of C1-01 to C1-09 0: 0.01 sec (0.00 to 600.00 sec) 1: 0.1 sec (0.0 to 6000.0 sec) 0 to 1 1 A A A A C1-11 Accel/Decel Switch Frequency Acc/Dec SW Freq Sets the frequency for automatic switching of accel / decel times. Fout < C1-11: Accel/Decel Time 4 Fout ≥ C1-11: Accel/Decel Time 1 Multi-function inputs "Multi-Acc/Dec 1" and "Multi-Acc/Dec 2" have priority over C1-11. Varies by Duty Rating* 0.0Hz A A A A 0.20sec A A A A 0.20sec A A A A 0.20sec A A A A 0.00sec A A A A 0.0 to 6000.0 10.0sec S-Curve Accel / Decel C2-01 S-Curve Characteristic at Accel Start SCrv Acc @ Start C2-02 S-Curve Characteristic at Accel End SCrv Acc @ End C2-03 S-Curve Characteristic at Decel Start SCrv Dec @ Start S-curve is used to further soften the starting and stopping ramp. The longer the S-curve time, the softer the starting and stopping ramp. Run command ON OFF 0.00 to 2.50 Output frequency C2-02 C2-04 S-Curve Characteristic at Decel End SCrv Dec @ End C2-01 C2-03 C2-04 Time Denotes that parameter can be changed when the Drive is running. * For Heavy Duty (HD) Rating: Setting Range=0.0 to 300.0. For Normal Duty (ND) Rating: Setting Range=0.0 to 400.0. Parameters A - 9 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector Slip Compensation Gain Slip Comp Gain This parameter is used to increase motor speed to account for motor slip by boosting the output frequency. If the speed is lower than the frequency reference, increase C3-01. If the speed is higher than the frequency reference, decrease C3-01. 0.0 to 2.5 1.0 A - A A C3-02 Slip Compensation Primary Delay Time Slip Comp Time This parameter adjusts the filter on the output of the slip compensation function. Increase to add stability, decrease to improve response. 0 to 10000 200ms A - A - C3-03 Slip Compensation Limit Slip Comp Limit This parameter sets the upper limit for the slip compensation function. It is set as a percentage of motor rated slip (E2-02). 0 to 250 200% A - A - C3-04 Slip Compensation Selection During Regeneration Slip Comp Regen Determines whether slip compensation is enabled or disabled during regenerative operation. 0: Disabled 1: Enabled 0 to 1 0 A - A - C3-05 Output Voltage Limit Operation Selection Output V Lim SEL Determines if the motor magnetic flux is automatically decreased when output voltage saturation occurs. 0: Disabled 1: Enabled 0 to 1 0 - - A A This parameter sets the gain for the Drive’s automatic torque boost function to match the Drive’s output voltage to the motor load. This parameter helps to produce better starting torque. It determines the amount of torque or voltage boost based upon motor current, motor resistance, and output frequency. 0.00 to 2.50 1.00 A A A - This parameter adjusts the filter on the output of the torque compensation function. Increase to add stability, decrease to improve response. 0 to 10000 20ms A A A - Description Motor-Slip Compensation C3-01 Torque Compensation C4-01 C4-02 Torque Compensation Gain Torq Comp Gain Torque Compensation Primary Delay Time Torq Comp Time C4-03 Torque Compensation at Forward Start F TorqCmp @ start Sets torque compensation at forward start as a percentage of motor torque. 0.0 to 200.0 0.0% - - A - C4-04 Torque Compensation at Reverse Start R TorqCmp @ start Sets torque compensation at reverse start as a percentage of motor torque. -200.0 to 0.0 0.0% - - A - C4-05 Torque Compensation Time Constant TorqCmp Delay T Sets the time constant for torque compensation at forward start and reverse start (C4-03 and C4-04). The filter is disabled if the time is set to 4ms or less. 0 to 200 10ms - - A - Denotes that parameter can be changed when the Drive is running. Parameters A - 10 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector ASR Tuning C5-01 ASR Proportional Gain 1 ASR P Gain 1 Sets the proportional gain of the speed control loop (ASR) 1.00 to 300.00 20.00 - A - A C5-02 ASR Integral Time 1 ASR I Time 1 Sets the integral time of the speed control loop (ASR) 0.000 to 10.000 0.500 sec - A - A C5-03 ASR Proportional Gain 2 ASR P Gain 2 Sets the speed control gain 2 and integral time 2 of the speed control loop (ASR). 1.00 to 300.00 20.00 - A - A 0.000 to 10.000 0.500 sec - A - A 0.0 to 20.0 5.0% - A - - 0.000 to 0.500 0.004 sec - - - A 0.0 to 400.0 0.0Hz - - - A 0 to 400 400% - - - A Drive Duty Selection Heavy/Normal Duty Selects Drive’s rated input and output current, overload capacity, carrier frequency, current limit, and maximum output frequency. See Introduction for details. 0: Heavy Duty (C6-02 = 0 to 1) 1: Normal Duty 1 (C6-02 = 0 to F) 2: Normal Duty 2 (C6-02 = 0 to F) 0 to 2 0 A A A A C6-02 Carrier Frequency Selection CarrierFreq Sel Selects the number of pulses per second of the output voltage waveform. Setting range determined by C6-01 setting. 0: Low noise 1: Fc = 2.0 kHz 2: Fc = 5.0 kHz 3: Fc = 8.0 kHz 4: Fc = 10.0 kHz 5: Fc = 12.5 kHz 6: Fc = 15.0 kHz F: Program (Determined by the settings of C6-03 thru C6-05) Varies by kVA Varies by kVA Q Q Q Q C6-03 Carrier Frequency Upper Limit CarrierFreq Max Maximum carrier frequency allowed when C6-02 = F. 0.4 to 15.0 kHz Varies by kVA A A A A C6-04 Carrier Frequency Lower Limit CarrierFreq Min Minimum carrier frequency allowed when C6-02 = F. 0.4 to 15.0 kHz Varies by kVA A A - - C6-05 Carrier Frequency Proportional Gain CarrierFreq Gain Sets the relationship of output frequency to carrier frequency when C6-02 = F. 0 to 99 0 A A - - P, I Flux Vector C5-01/02 C5-03/04 C5-04 ASR Integral Time 2 ASR I Time 2 C5-07 P, I Hz V/F with PG P = C5-01 I = C5-02 P = C5-03 I = C5-04 E1-04 Hz C5-05 ASR Limit ASR Limit Sets the upper limit for the speed control loop (ASR) as a percentage of the maximum output frequency (E1-04). C5-06 ASR Primary Delay Time Constant ASR Delay Time Sets the filter time constant for the time from the speed loop to the torque command output. C5-07 ASR Gain Switching Frequency ASR Gain SW Freq Sets the frequency for switching between Proportional Gain 1, 2 and Integral Time 1, 2. C5-08 ASR Integral Limit ASR I Limit Sets the ASR integral upper limit and rated load as a percentage of the rated torque of the connected motor. Carrier Frequency C6-01 Denotes that parameter can be changed when the Drive is running. Parameters A - 11 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector Preset Reference d1-01 Frequency Reference 1 Reference 1 Setting units are affected by o1-03. 0.00Hz Q Q Q Q d1-02 Frequency Reference 2 Reference 2 Frequency reference when multi-function input “Multi-step speed reference 1” is ON. Setting units are affected by o1-03. 0.00Hz Q Q Q Q d1-03 Frequency Reference 3 Reference 3 Frequency reference when multi-function input “Multi-step speed reference 2” is ON. Setting units are affected by o1-03. 0.00Hz Q Q Q Q d1-04 Frequency Reference 4 Reference 4 Frequency reference when multi-function input “Multi-step speed reference 1,2” is ON. Setting units are affected by o1-03. 0.00Hz Q Q Q Q d1-05 Frequency Reference 5 Reference 5 Frequency reference when multi-function input “Multi-step speed reference 3” is ON. Setting units are affected by o1-03. 0.00Hz A A A A d1-06 Frequency Reference 6 Reference 6 Frequency reference when multi-function input “Multi-step speed reference 1,3” is ON. Setting units are affected by o1-03. 0.00Hz A A A A d1-07 Frequency Reference 7 Reference 7 Frequency reference when multi-function input “Multi-step speed reference 2,3” is ON. Setting units are affected by o1-03. 0.00Hz A A A A d1-08 Frequency Reference 8 Reference 8 Frequency reference when multi-function input “Multi-step speed reference 1,2,3” is ON. Setting units are affected by o1-03. 0.00Hz A A A A d1-09 Frequency Reference 9 Reference 9 Frequency reference when multi-function input “Multi-step speed reference 4” is ON. Setting units are affected by o1-03. 0.00Hz A A A A d1-10 Frequency Reference 10 Reference 10 Frequency reference when multi-function input “Multi-step speed reference 1,4” is ON. Setting units are affected by o1-03. 0.00Hz A A A A d1-11 Frequency Reference 11 Reference 11 Frequency reference when multi-function input “Multi-step speed reference 2,4” is ON. Setting units are affected by o1-03. 0.00Hz A A A A d1-12 Frequency Reference 12 Reference 12 Frequency reference when multi-function input “Multi-step speed reference 1,2,4” is ON. Setting units are affected by o1-03. 0.00Hz A A A A d1-13 Frequency Reference 13 Reference 13 Frequency reference when multi-function input “Multi-step speed reference 3,4” is ON. Setting units are affected by o1-03. 0.00Hz A A A A d1-14 Frequency Reference 14 Reference 14 Frequency reference when multi-function input “Multi-step speed reference 1,3,4” is ON. Setting units are affected by o1-03. 0.00Hz A A A A d1-15 Frequency Reference 15 Reference 15 Frequency reference when multi-function input “Multi-step speed reference 2,3,4” is ON. Setting units are affected by o1-03. 0.00Hz A A A A d1-16 Frequency Reference 16 Reference 16 Frequency reference when multi-function input “Multi-step speed reference 1,2,3,4” is ON. Setting units are affected by o1-03. 0.00Hz A A A A Jog Frequency Reference Jog Reference Frequency reference when: “Jog frequency reference” is selected via multi-function input terminals. “Jog frequency reference” has priority over “multi-step speed reference 1 to 4”. d1-17 is also the reference for the JOG key on the Digital Operator, and the multi-function inputs “forward jog” and “reverse jog”. Setting units are affected by o1-03. 6.00Hz Q Q Q Q d1-17 0.00 to E1-04 Value Reference Limits d2-01 Frequency Reference Upper Limit Ref Upper Limit Determines maximum frequency reference, set as a percentage of maximum output frequency (E1-04). If the frequency reference is above this value, actual Drive speed will be limited to this value. This parameter applies to all frequency reference sources. 0.0 to 110.0 100.0% A A A A d2-02 Frequency Reference Lower Limit Ref Lower Limit Determines minimum frequency reference, set as a percentage of maximum output frequency (E1-04). If frequency reference is below this value, actual Drive speed will be set to this value. This parameter applies to all frequency reference sources. 0.0 to 110.0 0.0% A A A A d2-03 Master Speed Reference Lower Limit Ref1 Lower Limit Determines minimum frequency reference, set as a percentage of maximum output frequency (E1-04). If frequency reference from analog input (A1, A2, and A3) is below this value, actual Drive speed will be set to this value. This parameter applies only to analog inputs A1, A2, and A3. 0.0 to 110.0 0.0% A A A A Denotes that parameter can be changed when the Drive is running. Parameters A - 12 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0.0Hz A A A A 0.0Hz A A A A 0.0Hz A A A A Jump Frequencies d3-01 Jump Frequency 1 Jump Freq 1 d3-02 Jump Frequency 2 Jump Freq 2 d3-03 Jump Frequency 3 Jump Freq 3 d3-04 Jump Frequency Width Jump Bandwidth These parameters allow programming of up to three prohibited frequency reference points for eliminating problems with resonant vibration of the motor / machine. This feature does not actually eliminate the selected frequency values, but will accelerate and decelerate the motor through the prohibited bandwidth. Varies by Duty Rating* This parameter determines the width of the deadband around each selected prohibited frequency reference point. A setting of "1.0" will result in a deadband of +/- 1.0Hz. 0.0 to 20.0 1.0Hz A A A A 0 to 1 0 A A A A 0 to 100 10% A A A A 0 to 1 0 - - - A Sequence (MOP & Trim Control) d4-01 Frequency Reference Hold Function Selection MOP Ref Memory This parameter is used to retain the held frequency reference in U1-01 (d1-01) when power is removed. This function is available when the multi-function inputs “accel/decel ramp hold” or “up/down” commands are selected (H1-XX = A or 10 and 11). 0: Disabled 1: Enabled d4-02 Trim Control Level Trim Control Lvl Sets the amount of frequency reference to be added or subtracted as a percentage of maximum output frequency (E1-04) when multifunction inputs “trim control increase” and “trim control decrease” are selected (H1-XX = 1C and 1D). Torque Control d5-01 Torque Control Selection Torq Control Sel Selects speed or torque control. The torque reference is set via analog input A2 or A3 when it is set for “torque reference” (H3-05 or H3-09 = 13). Torque reference is set as a percentage of motor rated torque. To use this function for switching between speed and torque control, set to 0 and set a multi-function input to “speed/torque control change” (H1-XX = 71). 0: Speed Control (controlled by C5-01 to C5-07) 1: Torque Control d5-02 Torque Reference Delay Time Torq Ref Filter Sets the torque reference delay time in ms units. This function can be used to correct for noise in the torque control signal or the responsiveness with the host controller. When oscillation occurs during torque control, increase the set value. 0 to 1000 0ms - - - A Speed Limit Selection Speed Limit Sel Sets the speed limit command method for the torque control method. 1: Analog Input - Limited by the output of the soft starter (b1-01 selection and active acceleration/deceleration and S-curve settings). 2: Program Setting - Limited by d5-04 setting value. 1 to 2 1 - - - A d5-04 Speed Limit Speed Lmt Value Sets the speed limit during torque control as a percentage of the maximum output frequency (E1-04). This function is enabled when d5-03 is set to 2. Directions are as follows. +: run command direction -: run command opposite direction -120 to 120 0% - - - A d5-05 Speed Limit Bias Speed Lmt Bias Sets the speed limit bias as a percentage of the maximum output frequency (E1-04). Bias is given to the specified speed limit. It can be used to adjust the margin for the speed limit. 0 to 120 10% - - - A d5-06 Speed/Torque Control Switchover Timer Ref Hold Time Set the delay time from inputting the multi-function input “speed/torque control change” (from On to OFF or OFF to ON) until the control is actually changed. This function is enabled when the multi-function input “speed/torque control change” (H1-XX = 71) is set. While in the speed/torque control switching timer, the analog inputs hold the value present when the “speed/torque control change” is received. 0 to 1000 0ms - - - A d5-03 Denotes that parameter can be changed when the Drive is running. * For Heavy Duty (HD) Rating: Setting Range=0.0 to 300.0. For Normal Duty (ND) Rating: Setting Range=0.0 to 400.0. Parameters A - 13 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector Field-Weakening d6-01 Magnetic Field Weakening Level Field-Weak Lvl Sets the Drive output voltage when the multi-function input “field weakening command” is input (H1-XX = 63). Sets as a percentage taking the voltage set in the V/F pattern as 100%. 0 to 100 80% A A - - d6-02 Magnetic Field Frequency Field-Weak Freq Sets the lower limit (in Hz) of the frequency range where field weakening control is valid. The field weakening command is valid only at frequencies above this setting and only when output frequency is in agreement with the current output frequency (speed agree). Varies by Duty Rating* 0.0Hz A A - - d6-03 Magnetic Field Forcing Function Selection Field Force Sel Sets the magnetic field forcing function. 0: Disabled 1: Enabled 0 to 1 0 - - - A d6-06 Magnetic Field Forcing Limit Field Force Limit Sets the upper limit of the excitation current command during magnetic field forcing. A setting of 100% is equal to motor no-load current, E2-03. 100 to 400 400% - - A A 230.0V or 460.0V Q Q Q Q F Q Q - - V/F Pattern Set to the nominal voltage of the incoming line. Sets the maximum and base voltage used by preset V/F patterns (E1-03 = 0 to E), adjusts the levels of Drive protective features (e.g. Overvoltage, braking resistor turn-on, stall prevention, etc.). E1-01 E1-03 Input Voltage Setting Input Voltage V/F Pattern Selection V/F Selection WARNING DRIVE INPUT VOLTAGE (NOT MOTOR VOLTAGE) MUST BE SET IN E1-01 FOR THE PROTECTIVE FEATURES OF THE DRIVE TO FUNCTION PROPERLY. FAILURE TO DO SO MAY RESULT IN EQUIPMENT DAMAGE AND/OR PERSONAL INJURY. Set to the type of motor being used and the type of application. The Drive operates utilizing a set V/F pattern to determine the appropriate output voltage level for each commanded speed. There are 15 different preset V/F patterns to select from (E1-03 = 0 to E) with varying voltage profiles, base levels (base level = frequency at which maximum voltage is reached), and maximum frequencies. There are also settings for Custom V/F patterns that will use the settings of parameters E1-04 through E1-13. E1-03 = F selects a custom V/F pattern with an upper voltage limit and E1-03 = FF selects a custom V/F pattern without an upper voltage limit. 0: 50Hz 1: 60Hz Saturation 2: 50Hz Saturation 3: 72Hz (60Hz Base) 4: 50Hz VT1 5: 50Hz VT2 6: 60Hz VT1 7: 60Hz VT2 8: 50Hz HST1 9: 50Hz HST2 A: 60Hz HST1 B: 60Hz HST2 C: 90Hz (60Hz Base) D: 120Hz (60Hz Base) E: 180Hz (60Hz Base) F: Custom V/F FF: Custom w/o limit 155.0 to 255.0 (240V) 310.0 to 510.0 (480V) 0 to FF Denotes that parameter can be changed when the Drive is running. * For Heavy Duty (HD) Rating: Setting Range=0.0 to 300.0. For Normal Duty (ND) Rating: Setting Range=0.0 to 400.0. Parameters A - 14 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. E1-04 E1-05 Parameter Name Digital Operator Display Maximum Output Frequency Max Frequency Maximum Output Voltage Max Voltage Description These parameters are only applicable when V/F Pattern Selection is set to Custom (E1-03 = F or FF). To set V/F characteristics in a straight line, set the same values for E1-07 and E1-09. In this case, the setting for E1-08 will be disregarded. Be sure that the four frequencies are set in the following manner or else an OPE10 fault will occur: E1-04 ≥ E1-11 ≥ E1-06 > E1-07 ≥ E1-09 Note: Setting parameter E1-01=0 is also acceptable E1-06 Base Frequency Base Frequency E1-07 Mid Output Frequency A Mid Frequency A Output voltage (V) E1-05 E1-12 E1-13 E1-08 Mid Output Voltage A Mid Voltage A E1-09 Minimum Output Frequency Min Frequency E1-08 E1-10 E1-10 Minimum Output Voltage Min Voltage E1-09 E1-07 E1-06 E1-11 E1-04 Frequency (Hz) E1-11 E1-12 E1-13 Mid Output Frequency B Mid Frequency B Mid Output Voltage B Mid Voltage B Base Voltage Base Voltage Set only when the V/F pattern is finely adjusted in the constant power (HP) area above base speed. Adjustment is not normally required. Set only when the V/F pattern is finely adjusted in the constant power (HP) area above base speed. Adjustment is not normally required. If E1-13 = 0.0, then value in E1-05 is used for E1-13. Auto-Tuning sets this value. Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector Varies by Duty Rating* 60.0Hz Q Q Q Q 0.0 to 255.0 (240V) 0.0 to 510.0 (480V) 230.0V or 460.0V Q Q Q Q 0.0 to 400.0 60.0Hz Q Q Q Q 0.0 to 400.0 3.0Hz A A A - 0.0 to 255.0 (240V) 0.0 to 510.0 (480V) 12.6 Vac or 25.3 Vac A A A - 0.0 to 400.0 0.5Hz Q Q Q A 0.0 to 255.0 (240V) 0.0 to 510.0 (480V) 2.3 Vac or 4.6 Vac A A A - 0.0 to 400.0 0.0Hz A A A A 0.0 to 255.0 (240V) 0.0 to 510.0 (480V) 0.0Vac A A A A 0.0 to 255.0 (240V) 0.0 to 510.0 (480V) 0.0Vac A A Q Q Denotes that parameter can be changed when the Drive is running. * For Heavy Duty (HD) Rating: Setting Range=40.0 to 300.0. For Normal Duty (ND) Rating: Setting Range=40.0 to 400.0. Parameters A - 15 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector Motor Setup E2-01 Motor Rated Current Motor Rated FLA Set to the motor nameplate full load current in amperes (A). This value is automatically set during Auto-Tuning. Varies by kVA Varies by kVA Q Q Q Q E2-02 Motor Rated Slip Motor Rated Slip Set to the motor rated slip in hertz (Hz). This value is automatically set during rotational Auto-Tuning. Varies by kVA Varies by kVA A A A A E2-03 Motor No-Load Current No-Load Current Set to the magnetizing current of the motor as a percentage of full load amps (E2-01). This value is automatically set during rotational Auto-Tuning. Varies by kVA Varies by kVA A A A A E2-04 Number of Motor Poles Number of Poles Set to the number of motor poles. This value is automatically set during Auto-Tuning. 2 to 48 4 - Q - Q E2-05 Motor Line-to-Line Resistance Term Resistance Set to the phase-to-phase motor resistance in ohms (Ω). This value is automatically set by Auto-Tuning. 0.000 to 65.000 Varies by kVA A A A A E2-06 Motor Leakage Inductance Leak Inductance Set to the voltage drop due to motor leakage inductance as a percentage of motor rated voltage. This value is automatically set during Auto-Tuning. 0.0 to 40.0% Varies by kVA - - A A E2-07 Motor Iron-core Saturation Coefficient 1 Saturation Comp 1 Set to the motor iron saturation coefficient at 50% of magnetic flux. This value is automatically set during rotational Auto-Tuning. 0.00 to 0.50 0.50 - - A A E2-08 Motor Iron-core Saturation Coefficient 2 Saturation Comp 2 Set to the motor iron saturation coefficient at 75% of magnetic flux. This value is automatically set during rotational Auto-Tuning. 0.50 to 0.75 0.75 - - A A E2-09 Motor Mechanical Loss Mechanical Loss Set to the motor mechanical loss as a percentage of motor rated power (kW) capacity. Adjust in the following circumstances: • When torque loss is large due to motor bearing friction. • When the torque loss in the load is large. 0.0 to 10.0 0.0% - - A A E2-10 Motor Iron Loss for Torque Compensation Tcomp Iron Loss Set to the motor iron loss in watts (W). 0 to 65535 W Varies by kVA A A - - E2-11 Motor Rated Output Mtr Rated Power Set to the motor rated power in kilowatts (kW). This value is automatically set during Auto-Tuning. 1HP = 0.746kW 0.00 to 650.00 kW Varies by kVA Q Q Q Q E2-12 Motor Iron-Core Saturation Coefficient 3 Saturation Comp 3 Set to the motor iron saturation coefficient at 130% of magnetic flux. This value is automatically set during rotational Auto-Tuning. 0.0 to 1.60 1.30 - - A A Denotes that parameter can be changed when the Drive is running. Parameters A - 16 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0 to 3 2 A A A A Varies by Duty Rating* 60.0Hz A A A A 0.0 to 255.0 (240V) 0.0 to 510.0 (480V) 230.0V or 460.0V A A A A 0.0 to 400.0 60.0Hz A A A A A A A - V/F Pattern 2 E3-01 Motor 2 Control Method Selection Control Method E3-02 Motor 2 Maximum Output Frequency Max Frequency 0: 1: 2: 3: V/F control V/F control with PG Open-loop vector control Flux vector control Output voltage (V) E3-03 Motor 2 Maximum Output Voltage Max Voltage E3-04 Motor 2 Base Frequency Base Frequency E3-05 Motor 2 Mid Output Frequency Mid Frequency E3-06 Motor 2 Mid Output Voltage VA Mid Voltage E3-07 Motor 2 Minimum Output Frequency Min Frequency E3-08 Motor 2 Minimum Output Voltage Min Voltage E3-03 E3-06 0.0 to 400.0 E3-08 E3-07 E3-05 E3-04 E3-02 Frequency (Hz) To set V/F characteristics in a straight line, set the same values for E3-05 and E3-07. In this case, the setting for E3-06 will be disregarded. Be sure that the four frequencies are set in the following manner or else an OPE10 fault will occur: E3-02 ≥ E3-04 ≥ E3-05 ≥ E3-07 3.0Hz 0.0 to 255.0 (240V) 0.0 to 510.0 (480V) 12.6 Vac or 25.3 Vac A A A - 0.0 to 400.0 0.5Hz A A A A 0.0 to 255.0 (240V) 0.0 to 510.0 (480V) 2.3Vac or 4.6Vac A A A - Motor Setup 2 E4-01 Motor 2 Rated Current Motor Rated FLA Set to the motor 2 nameplate full load current in amperes (A). This value is automatically set during Auto-Tuning. Varies by kVA Varies by kVA A A A A E4-02 Motor 2 Rated Slip Motor Rated Slip Set to the rated slip of motor 2 in hertz (Hz). This value is automatically set during rotational Auto-Tuning. Varies by kVA Varies by kVA A A A A E4-03 Motor 2 No-Load Current No-Load Current Set to the magnetizing current of motor 2 in percentage of full load current (E4-01). This value is automatically set during rotational Auto-Tuning. Varies by kVA Varies by kVA A A A A E4-04 Motor 2 Number of Poles Number of Poles Set to the number of poles of motor 2. This value is automatically set during Auto-Tuning. 2 to 48 4 - A - A E4-05 Motor 2 Line-to-Line Resistance Term Resistance Set to the phase-to-phase resistance of motor 2 in ohms (Ω). This value is automatically set by the Auto-Tuning. 0.000 to 65.000 Varies by kVA A A A A E4-06 Motor 2 Leakage Inductance Leak Inductance Set to the voltage drop due to motor leakage inductance as a percentage of rated voltage of motor 2. This value is automatically set during Auto-Tuning. 0.0 to 40.0% Varies by kVA - - A A E4-07 Motor 2 Rated Output Mtr Rated Power Set to the rated power of motor 2 in kilowatts (kW). This value is automatically set during Auto-Tuning. 0.00 to 650.00 kW Varies by kVA A A A A Denotes that parameter can be changed when the Drive is running. * For Heavy Duty (HD) Rating: Setting Range=40.0 to 300.0. For Normal Duty (ND) Rating: Setting Range=40.0 to 400.0. Parameters A - 17 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting 0.0 to 2.5 V/F V/F w/PG Open Loop Vector Flux Vector 1.0 *1 A No A A 0.00 to 300.00 *2 20.00 *3 No A No A E4-08 <3021> Motor 2 Slip Compensation Gain SlpCmp Gain Mtr2 This parameter can help to increase speed precision when working on a load, although normally adjustment is not necessary. • When speed is less than that desired value, increase the set value. • When speed is higher than the desired value, decrease the set value. * This parameter functions as gain suppression when in Flux Vector Control. E4-09 <3021> Motor 2 ASR Proportional (P) Gain 1 ASR P Gain Mtr2 Sets the proportional gain of the speed loop (ASR). E4-10 <3021> Motor 2 ASR Integral (I) Time 1 ASR I Time Mtr2 Sets the integral time of the speed loop (ASR) in units of 0.1s. 0.000 to 10.000 0.500 sec *3 N0 A No A Motor 2 Torque Compensation Gain TrqCmp Gain Mtr2 Magnifies the torque compensation gain. Normally this parameter does not require change, however, adjustments can be made as follows: • When the motor cable is long, increase the setting. • When using a motor with a smaller capacity than the drive (the largest motor being used), increase this setting. • If the motor begins to vibrate, adjust the value set so that the output current does not exceed the drive’s rated output current when operating at low speeds. 0.00 to 2.50 1.00 A A A No PG Parameter PG Pulses/Rev Sets the number of pulses per revolution (PPM) of the encoder (pulse generator). 0 to 60000 1024 - Q - Q Operation Selection at PG Open Circuit (PGO) PG Fdbk Loss Sel Sets stopping method when a PG open circuit fault (PGO) occurs. See parameter F1-14. 0: Ramp to stop - Decelerate to stop using the active deceleration time. 1: Coast to stop 2: Fast - Stop - Decelerate to stop using the deceleration time in C1-09. 3: Alarm Only - Drive continues operation. 0 to 3 1 - A - A Operation Selection at Overspeed (OS) PG Overspeed Sel Sets the stopping method when an overspeed (OS) fault occurs. See F1-08 and F1-09. 0: Ramp to stop - Decelerate to stop using the active deceleration time. 1: Coast to stop 2: Fast - Stop - Decelerate to stop using the deceleration time in C1-09. 3: Alarm Only - Drive continues operation. 0 to 3 1 - A - A F1-04 Operation Selection at Deviation PG Deviation Sel Sets the stopping method when a speed deviation (DEV) fault occurs. See F1-10 and F1-11. 0: Ramp to stop - Decelerate to stop using the active deceleration time. 1: Coast to stop 2: Fast - Stop - Decelerate to stop using the deceleration time in C1-09. 3: Alarm Only - Drive continues operation. 0 to 3 3 - A - A F1-05 PG Rotation Selection PG Rotation Sel 0: Fwd=C.C.W. - Phase A leads with forward run command. (Phase B leads with reverse run command.) 1: Fwd=C.W. - Phase B leads with forward run command. (Phase A leads with reverse run command.) 0 to 1 0 - A - A Sets the division ratio for the pulse monitor of the PG-B2 encoder feedback option board. This function is not available with the PG-X2 option board. Division ratio = (1+ n) /m (n=0 to 1, m=1 to 32) The first digit of the value of F1-06 stands for n, the second and the third stand for m. (from left to right). The possible division ratio settings are: 1/32 ≤ F1-06 ≤ 1 1 to 132 1 - A - A E4-11 <3021> PG Option Setup F1-01 F1-02 F1-03 F1-06 PG Division Rate (PG Pulse Monitor) PG Output Ratio Denotes that parameter can be changed when the Drive is running. For Normal Duty (ND) Rating: Setting Range=40.0 to 400.0. * For Heavy Duty (HD) Rating: Setting Range=40.0 to 300.0. *1: Default setting changes according to the control mode (E3-01). When E3-01 = 0, E4-08 = 0.0. When E3-01 = 2 or 3, E4-08 = 1.0. *2: Setting range becomes 1.00 to 300.00 in Flux Vector Control *3: Default setting changes according to the control mode (E3-01) When E3-01 = 1, E4-09 = 0.20 and E4-10 = 0.200. When E3-01 = 3, E4-09 = 20.00 and E4-10 = 0.500. Parameters A - 18 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector Sets integral control during acceleration/deceleration to either enabled or disabled. 0: Disabled - The integral function is not used while accelerating or decelerating. 1: Enabled - The integral function is used at all times. 0 to 1 0 - A - - 0 to 120 115% - A - A 0.0 to 2.0 0.0 sec - A - A 0 to 50 10% - A - A 0.0 to 10.0 0.5 sec - A - A 0 - A - - 0 - A - - F1-07 Integral Function During Accel/Decel Selection PG Ramp PI/I Sel F1-08 Overspeed Detection Level PG Overspd Level F1-09 Overspeed Detection Delay Time PG Overspd Time F1-10 Excessive Speed Deviation Detection Level PG Deviate Level F1-11 Excessive Speed Deviation Detection Level PG Deviate Level F1-12 Number of PG Gear Teeth 1 PG # Gear Teeth1 F1-13 Number of PG Gear Teeth 2 PG # Gear Teeth2 A gear ratio of 1 will be used if either of these parameters is set to 0. This function is not available in flux vector control. F1-14 PG Open-Circuit Detection Time PGO Detect Time Configures the PG open (PGO) function. PGO will be detected if no PG pulses are detected for a time longer than F1-14. See F1-02. 0.0 to 10.0 2.0 sec - A - A F1-21 <3021> PG Constant 2 PG Pulse / Rev 2 Sets the number of pulses for the encoder (pulse generator) for each full rotation of Motor 2. 0 to 60000 1024 No Q No Q F1-22 <3021> PG Rotation 2 PG Rotation Sel2 Determines the direction of rotation for the encoder (PG) connected to Motor 2. 0: Phase A leads with Forward Run Command. (Phase B leads with Reverse Run Command.) 1: Phase B leads with Forward Run Command. (Phase A leads with Reverse Run Command.) 0, 1 0 No Q No Q F1-23 <3021> Number of PG Gear Teeth 1 PG Gear Teeth1 Sets the number of gear teeth (deceleration ratio) between Motor 2 and the pulse generator. 0 to 1000 0 No A No No 0 to 1000 0 No A No No Configures the overspeed fault (OS) detection. OS fault will occur, if the motor speed feedback is greater than the F1-08 setting for a time longer than F1-09. F1-08 is set as a percentage of the maximum output frequency (E1-04). See F1-03. Configures the speed deviation fault (DEV) detection. DEV fault will occur if the speed deviation is greater than the F1-10 setting for a time longer than F1-11. F1-10 is set as a percentage of the maximum output frequency (E1-04). Speed deviation is the difference between actual motor speed and the frequency reference command. See F1-04. Sets the gear ratio between the motor shaft and the encoder (PG). Input pulses from PG (PPR) x 60 x F1-13 F1-01 F1-12 0 to 1000 Input pulses from PG (PPR) x 60 x F1-24 PG Constant (F1-21) F1-23 F1-24 <3021> Number of PG Gear Teeth 2 PG Gear Teeth2 F1-25 <3021> Hardware Disconnect Detection Selection CH 1 Hardware PGO ch1 Enables or disables the drive from detecting when the PG option on CH1 has been disconnected. 0: Disabled 1: Enabled Enabled when using PG-T2 or Z2. 0, 1 1 No A No A F1-26 <3021> Hardware Disconnect Detection Selection CH 2 Hardware PGO ch2 Enables or disables the drive from detecting when the PG option on CH2 has been disconnected. 0: Disabled 1: Enabled Enabled when using PG-Z2. 0, 1 1 No A No A AI-14 Input Selection AI-14 Input Sel Sets the function for channel 1 to 3 of the AI-14B analog input reference option board. 0: 3-channel individual (Channel 1: terminal A1, Channel 2: terminal A2, Channel 3: terminal A3) 1: 3-channel addition (Summed values of channels 1 to 3 is the frequency reference) When set to 0, select 1 for b1-01. In this case, the multi-function input “Option/Inverter selection” cannot be used. 0 to 1 0 A A A A A gear ratio of 1 will be used if either of these constants is set to 0. AI-14 Setup F2-01 Denotes that parameter can be changed when the Drive is running. * Enabled when an option card is connected to the PG encoder 2CH input (F1-21 to F1-24). Parameters A - 19 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0 to 7 0 A A A A 1 to 45 2 A A A A 0.0 to 1000.0 100.0% A A A A 1 to 45 3 A A A A DI-08, 16 Setup F3-01 DI-08 / DI-16H2 Input Selection DI Input Sets the function of the DI-08 or the DI-16H2 digital input option board. 0: BCD 1% unit 1: BCD 0.1% unit 2: BCD 0.01% unit 3: BCD 1Hz unit 4: BCD 0.1Hz unit 5: BCD 0.01Hz unit 6: BCD (5-digit) 0.01Hz unit (only effective when DI-16H2 is used.) 7: Binary input When o1-03 is set to 2 or higher, the input will be BCD, and the units will change to the o1-03 setting. F4-01 AO-08/AO-12 Channel 1 Monitor Selection AO Ch1 Sel Sets the number of the monitor item to be output. (U1The following settings cannot be set: 4, 10 to 14, 25, 28, 29, 30, 34, 35, 39, 40, 41. F4-02 AO-08/AO-12 Channel 1 Gain AO Ch1 Gain Sets the channel 1 gain. Ex: Set F4-02 = 50% to output 100% at 5.0V output. F4-03 AO-08/AO-12 Channel 2 Monitor Selection AO Ch2 Sel Sets the number of the monitor item to be output. (U1The following settings cannot be set: 4, 10 to 14, 25, 28, 29, 30, 34, 39, 40, 41. F4-04 AO-08/AO-12 Channel 2 Gain AO Ch2 Gain Sets the channel 2 gain. Ex: Set F4-04 = 50% to output 100% at 5.0V output. 0.0 to 1000.0 50.0% A A A A F4-05 AO-08/AO-12 Channel 1 Output Bias AO Ch1 Bias Sets the channel 1 bias (100%/10V). Ex: Set F4-05 = 50% to output 0% at 5.0V output. -110.0 to 110.0 0.0% A A A A F4-06 AO-08/AO-12 Channel 2 Output Bias AO Ch2 Bias Sets the channel 2 bias (100%/10V). Ex: Set F4-06 = 50% to output 0% at 5.0V output. -110.0 to 110.0 0.0% A A A A F4-07 AO-12 Channel 1 Signal Level AO Opt Level Ch1 Sets the range of the voltage output. 0: 0 to 10Vdc 1: -10 to +10Vdc 0 to 1 0 A A A A F4-08 AO-12 Channel 2 Signal Level AO Opt Level Ch2 Sets the range of the voltage output. 0: 0 to 10Vdc 1: -10 to +10Vdc 0 A A A A F5-01 DO-02/DO-08 Channel 1 Output Selection DO Ch1 Select Sets the digital output function number for channel 1. See the H2 parameter group for possible selections. Effective when digital output card DO-02 or DO-08 is used. 0 to 38 0 A A A A F5-02 DO-02/DO-08 Channel 2 Output Selection DO Ch2 Select Sets the digital output function number for channel 2. See the H2 parameter group for possible selections. Effective when digital output card DO-02 or DO-08 is used. 0 to 38 1 A A A A F5-03 DO-08 Channel 3 Output Selection DO Ch3 Select Sets the digital output function number for channel 3. See the H2 parameter group for possible selections. Effective when digital output card DO-02 or DO-08 is used. 0 to 38 2 A A A A F5-04 DO-08 Channel 4 Output Selection DO Ch4 Select Sets the digital output function number for channel 4. See the H2 parameter group for possible selections. Effective when digital output card DO-02 or DO-08 is used. 0 to 38 4 A A A A F5-05 DO-08 Channel 5 Output Selection DO Ch5 Select Sets the digital output function number for channel 5. See the H2 parameter group for possible selections. Effective when digital output card DO-02 or DO-08 is used. 0 to 38 6 A A A A F5-06 DO-08 Channel 6 Output Selection DO Ch6 Select Sets the digital output function number for channel 6. See the H2 parameter group for possible selections. Effective when digital output card DO-02 or DO-08 is used. 0 to 38 37 A A A A F5-07 DO-08 Channel 7 Output Selection DO Ch7 Select Sets the digital output function number for channel 7. See the H2 parameter group for possible selections. Effective when digital output card DO-02 or DO-08 is used. 0 to 38 F A A A A AO-08, 12 Setup ) ) 0 to 1 DO-02, 08 Setup Denotes that parameter can be changed when the Drive is running. Parameters A - 20 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector F5-08 DO-08 Channel 8 Output Selection DO Ch8 Select Sets the digital output function number for channel 8. See the H2 parameter group for possible selections. Effective when digital output card DO-02 or DO-08 is used. 0 to 38 F A A A A F5-09 DO-08 Output Mode Selection DO-08 Selection Sets the function of the DO-08 digital output option board. 0: 8-channel individual outputs. 1: Binary code output. 2: 8-channel Selected - Output according to F5-01 to F5-08 settings. 0 to 2 0 A A A A F6-01 Operation Selection after Communication Error Comm Bus Flt Sel Selects the stopping method for a communication option board fault (BUS). Active only when a communication option board is installed and b1-01 or b1-02 = 3. 0: Ramp to Stop 1: Coast to Stop 2: Fast-Stop 3: Alarm Only 0 to 3 1 A A A A F6-02 Selection of External Fault from Communication Option Board EF0 Detection Selects the condition in which an EF0 fault is detected from a communication option board. Active only when a communication option board is installed and b1-01 or b1-02 = 3. 0: Always detected 1: Detected only during operation 0 to 1 0 A A A A F6-03 Stopping Method for External Fault from Communication Option Board EF0 Fault Action Selects the stopping method for an external fault from a communication option board (EF0). Active only when a communication option board is installed and b1-01 or b1-02 = 3. 0: Ramp to Stop 1: Coast to Stop 2: Fast-Stop 3: Alarm Only 0 to 3 1 A A A A F6-04 Trace Sampling from Communications Option Board Trace Sample Tim Sets the sample trace for the CP-916 option board. 0 to 60000 0 A A A A F6-05 Current Monitor Display Unit Selection Current Unit Sel Selects the current monitor scaling when using a communication option board. 0: Displayed in Amps 1: 100%/8192 (12 bit binary number with 8192=100% Drive’s rated current) 0 to 1 0 A A A A F6-06 Torque Reference/Torque Limit Selection from Communications Option Torq Ref/Lmt Sel Selects torque reference/limit when using communications option board. 0: Disabled -Torque reference/limit from option board disabled 1: Enabled -Torque reference/limit from option board enabled. 0 to 1 0 - - - A Communications Option Setup Denotes that parameter can be changed when the Drive is running. Parameters A - 21 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting 0 to 78 0 to 78 V/F V/F w/PG Open Loop Vector Flux Vector 24 A A A A 14 A A A A Digital Inputs H1-01 Multi-Function Digital Input Terminal S3 Function Selection Terminal S3 Sel H1-02 Multi-Function Digital Input Terminal S4 Function Selection Terminal S4 Sel Selects the function of terminals S3 to S8. 0: 3-wire control FWD/REV selection for 3-wire sequence. 1: Local/Remote Selection Closed = Local, Open = Remote. 2: Option/Inv Selection Selects source of frequency reference and sequence. Closed = Option Card, Open = b1-01 & b1-02. 3: Multi-Step Frequency Reference 1 Based on status of Multi-Step Reference 1 to 4 (d1-16). 4: Multi-Step Frequency Reference 2 Based on status of Multi-Step Reference 1 to 4 (d1-16). 5: Multi-Step Frequency Reference 3 Based on status of Multi-Step Reference 1 to 4 (d1-16). 6: Jog Frequency Reference Closed = frequency reference from d1-17 7: Accel/Decel Time Se1ection 1 Based on status of Accel/Decel Time Selection 1 and 2. 8: External BaseBlock N.O. Closed = Output transistors forced off. Open = Normal operation. 9: External BaseBlock N.C. Closed = Normal operation. Open = Output transistors forced off. A: Acc/Dec Ramp Hold Closed = Acceleration suspended and speed held. B: External Overheat Alarm (OH2) Closed = OH2 alarm. C: Terminal A2 Enable Closed = Terminal A2 is active. Open = Terminal A2 is disabled. D: V/F Control with PG Disabled Closed = Speed feedback control disabled. E: ASR Integral Reset Closed = Integral reset. F: Terminal Not Used Terminal closure has no effect. 10: MOP Increase Closed = frequency reference increases. Open = frequency reference held. Must be set in conjunction with MOP Decrease and b1-01 must be set to 1. 11: MOP Decrease Closed = frequency reference decreases. Open = frequency reference held. Must be set in conjunction with MOP Increase and b1-01 must be set to 1. 12: Forward Jog Closed = Drive runs forward at frequency reference entered into parameter d1-17. 13: Reverse Jog Closed = Drive runs in reverse at frequency reference entered into parameter d1-17. 14: Fault Reset Closed = Resets the Drive after the fault and the run command have been removed. (Continued on following page). Denotes that parameter can be changed when the Drive is running. Parameters A - 22 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. H1-03 H1-04 Parameter Name Digital Operator Display Multi-Function Digital Input Terminal S5 Function Selection Terminal S5 Sel Multi-Function Digital Input Terminal S6 Function Selection Terminal S6 Sel Description 15: Fast-Stop N.O. Closed = Drive decelerates using C1-09, regardless of run command status. 16: Motor 2 Selection Closed = Motor 2 (E3, E4) Open = Motor 1 (A1-02, E1, E2) 17: Fast-Stop N.C. Closed = Normal operation Open = Drive decelerates using C1-09, regardless of run command status. 18: Timer Function Input for independent timer, controlled by b4-01 and b4-02. Used in conjunction with the multi-function digital output function H2= 12 “timer output”. 19: PID Disable Closed = Turns off the PID controller. 1A: Accel / Decel Time Selection 2 Based on status of Accel/Decel Time Selection 1 and 2. 1B: Program Lockout Closed = All parameter settings can be changed. Open = Only U1-01 can be changed. 1C: Trim Control Increase Closed = Increase frequency reference by value in d4-02. Open = Return to normal frequency reference. Not effective when Preset References are selected (Multi-step speed digital inputs are closed). Must be used in conjunction with Trim Ctrl Decrease. 1D: Trim Control Decrease Closed = Decrease frequency reference by value in d4-02 Open = Return to normal frequency reference. Not effective when Preset References are selected (Multi-step speed digital inputs are closed). Must be used in conjunction with Trim Ctrl Increase. 1E: Reference Sample Hold Analog frequency reference is sampled then held at time of input closure. 20: External Fault, Normally Open, Always Detected, Ramp To Stop 21: External Fault, Normally Closed, Always Detected, Ramp To Stop 22: External Fault, Normally Open, During Run, Ramp To Stop 23: External Fault, Normally Closed, During Run, Ramp To Stop 24: External Fault, Normally Open, Always Detected, Coast To Stop 25: External Fault, Normally Closed, Always Detected, Coast To Stop 26: External Fault, Normally Open, During Run, Coast To Stop 27: External Fault, Normally Closed, During Run, Coast To Stop 28: External Fault, Normally Open, Always Detected, Fast-Stop 29: External Fault, Normally Closed, Always Detected, Fast-Stop 2A:External Fault, Normally Open, During Run, Fast-Stop 2B:External Fault, Normally Closed, During Run, Fast-Stop 2C:External Fault, Normally Open, Always Detected, Alarm Only 2D:External Fault, Normally Closed, Always Detected, Alarm Only 2E: External Fault, Normally Open, During Run, Alarm Only 2F: External Fault, Normally Closed, During Run, Alarm Only (Continued on following page). Denotes that parameter can be changed when the Drive is running. Parameters A - 23 Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector A A A A A A A A 3: 2-wire 0 to 78 0: 3-wire 4: 2-wire 0 to 78 3: 3-wire Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector A A A A A A A A Digital Inputs H1-05 H1-06 Multi-Function Digital Input Terminal S7 Function Selection Terminal S7 Sel Multi-Function Digital Input Terminal S8 Function Selection Terminal S8 Sel 30:PID integral reset Closed = Set integrator value to 0. 31: PID integral hold Closed = Hold integrator at its present level. 32: Multi-Step Reference 4 Based on the status of Multi-Step Reference 1 to 4 (d1-16). 34: PID Soft Starter Cancel Closed = b5-17 is ignored. 35: PID Input (Error) Polarity Change Closed = PID error signal polarity is reversed (1 to -1 or -1 to 1). 60: DC Injection Braking Closed = Apply DC injection current as set in parameter b2-02. 61: Speed Search 1 Closed = While a run command is given, Drive does a speed search starting at maximum frequency (E1-04). Speed search based on b3-01. 62: Speed Search 2 Closed = While a run command is given, Drive does a speed search starting at frequency reference. Speed search based on b3-01. 63: Field Weakening Command (Energy Savings) Closed = Field weakening control set for d6-01 and d6-02. 64: Speed Search 3 Closed = And a run command is given, Drive does a speed search starting at output frequency. Speed search based on b3-01. 65: Kinetic Energy Braking Ride-thru N.C. Closed = Normal operation Open = KEB ride-thru is enabled. 66: Kinetic Energy Braking Ride-thru N.O. Closed = KEB ride-thru is enabled. 67: Communications Test Mode Used to test Modbus RS-485/422 interface. 68: High Slip Braking Closed = Drive stops using High Slip Braking regardless of run command status. 69: Jog 2 Closed = Drive runs at frequency reference entered into parameter d1-17. Direction determined by fwd/rev input. 3-wire control Only. 6A: Drive Enable - Closed = Drive will accept run command. Open = Drive will not run. If running, Drive will stop per b1-03. 71: Speed / Torque Control Selection Closed = Torque control operation. Open = Speed control operation. 72: Zero-Servo Command Closed = Zero-Servo ON 77: ASR Gain Switch Open = ASR proportional gain is set according to C5-01. Closed = ASR proportional gain is set according to C5-03. 78: Polarity Reversing Command for External Torque Control Closed = Reverse polarity. Denotes that parameter can be changed when the Drive is running. Note: Some digital inputs are control method dependent. Parameters A - 24 6: 2-wire 0 to 78 4: 3-wire 0 to 78 8 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0 to 38 0 A A A A Digital Outputs H2-01 Terminal M1-M2 Function Selection Term M1-M2 Sel Selects the function of terminals M1 to M6. 0: During RUN 1 Closed = When a run command is input or the Drive is outputting voltage. 1: Zero Speed Closed = When Drive output frequency is less than minimum output frequency (E1-09) or less than DC Injection Braking Start Frequency (b2-01) when in Flux Vector Control Method. 2: Fref/Fout Agree 1 Closed = When Drive output frequency equals the frequency reference +/- the hysteresis of L4-02. 3: Fref/Set Agree 1 Closed = When the Drive output frequency and the frequency reference are equal to the value in L4-01+/- the hysteresis of L4-02. 4: Frequency Detection 1 Closed = When the Drive output frequency is less than or equal to the value in L4-01 with hysteresis determined by L4-02. 5: Frequency Detection 2 Closed = When the Drive output frequency is greater than or equal to the value in L4-01, with hysteresis determined by L4-02. 6: Inverter Ready Closed = When the Drive is powered up, not in a fault state, and in the DRIVE mode. 7: DC Bus Undervoltage Closed = When the DC bus voltage falls below the UV trip level set in L2-05. 8: Base Block 1 N.O. Closed = When the Drive is not outputting voltage. 9: Option Reference Closed = When the frequency reference is coming from the Digital Operator. A: LOCAL/REMOTE Operation Closed = When the run command is coming from the Digital Operator. B: Torque Detection 1 N.O. Closed = When the output current/torque exceeds the torque value set in parameter L6-02 for more time than is set in parameter L6-03. C: Loss of Reference Closed = When the Drive has detected a loss of the analog frequency reference. Frequency reference is considered lost when it drops 90% in 0.4 seconds. Parameter L4-05 determines Drive reaction to a loss of frequency reference. D: Braking Resistor Fault Closed = When braking resistor or transistor is overheating or has faulted. Only active when L8-01 = 1. E: Fault Closed = When the Drive experiences a major fault. F: Not Used 10:Minor Fault - Alarm Closed = When Drive experiences an alarm. (Continued on following page) Denotes that parameter can be changed when the Drive is running. Parameters A - 25 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display H2-02 Terminal M3-M4 Function Selection Term M3-M4 Sel H2-03 Terminal M5-M6 Function Selection Term M5-M6 Sel Description 11: Reset Command Active Closed = When the Drive receives a reset command from a digital input terminal or serial communication. 12: Timer Output Output for independent timer, controlled by b4-01 and b4-02. Used in conjunction with the digital input H1= 18 “timer function”. 13: Fref/Fout Agree 2 Closed = When Drive output frequency equals the frequency reference +/- the hysteresis of L4-04. 14: Fref/Set Agree 2 Closed = When the Drive output frequency and the frequency reference are equal to the value in L4-03 +/- the hysteresis of L4-04. 15: Frequency Detection 3 Closed = When the Drive output frequency is less than or equal to the value in L4-03 with the hysteresis determined by L4-04. 16: Frequency Detection 4 Closed = When the Drive output speed is greater than or equal to the value in L4-03, with the hysteresis determined by L4-04. 17: Torque Detection 1 N.C. Open = When the output current/torque exceeds the value set in parameter L6-02 for more time than is set in parameter L6-03. 18: Torque Detection 2 N.O. Closed = When the output current/torque exceeds the value set in parameter L6-05 for more time than is set in parameter L6-06. 19: Torque Detection 2 N.C. Open = when the output current/torque exceeds the value set in parameter L6-05 for more time than is set in parameter L6-06. 1A: Reverse Direction Closed = When the Drive is running in the reverse direction. 1B: Baseblock 2 N.C. Open = When Drive is not outputting voltage. 1C: Motor 2 Selection Closed = When motor 2 is selected by multi-function input “motor 2 selection”. 1D: Regenerating Closed = When in regenerating mode. 1E: Restart Enabled Closed = When the Drive is performing an automatic restart attempt. Automatic restart is configured by parameter L5-01. 1F: Overload (OL1) Closed = When OL1 function is at 90% of its trip point or greater. 20: OH Pre-Alarm Closed = When the Drive’s heatsink temperature exceeds the setting of parameter L8-02. 30: During Torque Limit (when in speed control) Closed = When in torque limit. 31: During Speed Limit Closed = When in speed limit. 32: During Speed Limit (when in torque control) Closed = When motor frequency is at the speed limit value when running in torque control. 33: Zero-Servo Complete Closed = When Zero Servo is complete within the b9-02 zero servo completion width. 36: Frequency Detection 5 <3021> Closed = When the Drive output speed is greater than or equal to the value in L4-03, with the hysteresis determined by L4-04. 37: During Run 2 Closed = When Drive is operating (except during baseblock or DC braking). 38: Drive Enable Closed = When the Drive enable input is active. 3D: Drive Cooling Fan Fault Detect <3021> Closed: When drive’s cooling fan fault is detected. Denotes that parameter can be changed when the Drive is running. Note: Some digital outputs are control method dependent. Parameters A - 26 Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0 to 38 1 A A A A 0 to 38 2 A A A A Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0 to 1 0 A A A A Analog Inputs H3-01 Terminal A1 Signal Level Selection Term A1 Lvl Sel Sets the signal level of terminal A1. 0: 0 to 10Vdc 1: -10 to +10Vdc H3-02 Terminal A1 Gain Setting Terminal A1 Gain Sets the output level when 10V is input, as a percentage of the maximum output frequency (E1-04). 0.0 to 1000.0 100.0% A A A A H3-03 Terminal A1 Bias Setting Terminal A1 Bias Sets the output level when 0V is input, as a percentage of the maximum output frequency (E1-04). –100.0 to +100.0 0.0% A A A A H3-04 H3-05 Terminal A3 Signal Level Selection Term A3 Signal Sets the signal level of terminal A3. 0: 0 to 10Vdc 1: -10 to +10Vdc 0 to 1 0 A A A A Terminal A3 Function Selection Terminal A3 Sel Selects the function of terminal A3. 0: Frequency Bias (Adds with terminal A1) 100% = Maximum output frequency (E1-04) 1: Frequency Reference Gain (FGAIN) 100% = Frequency reference command value A1 Total gain = Internal gain (H3-02) x FGAIN 2: Aux Frequency Reference 1 Used in conjunction with multi-function inputs “multi-step frequency reference 1-4” (d1-16). 100% = Maximum output frequency (E1-04) 3: Aux Frequency Reference 2 Used in conjunction with multi-function inputs “multi-step frequency reference 1-4” (H1-xx=3,4,5). 100% = Maximum output frequency (E1-04) 4: Output Voltage Bias 100% = Motor rated voltage (E1-05). Voltage boost after V/F pattern. 5: Accel / Decel Time Coefficient 100% = Active accel / decel time (C1-01 thru C1-08) 6: DC Injection Braking Current 100% = Drive rated current. Parameter b2-02 is disabled. 7: Overtorque / Undertorque Detection Level Used for multi-function digital output for “overtorque/undertorque”. 100% = motor rated torque (OLV, FV) or Drive rated current (V/F, V/F w/PG). Internal overtorque detection level (L6-02) disabled. 8: Stall Prevention Level During Run 100% = L3-06. 9: Frequency Reference Lower Limit 100% = Maximum output frequency (E1-04). Either d2-02 setting or A3 input level, whichever is greater, becomes effective. A: Jump Frequency 4 100% = Maximum output frequency (E1-04). B: PID Feedback 100% = Maximum output frequency (E1-04). C: PID Set Point 100% = Maximum output frequency (E1-04). Frequency reference no longer acts as a PID setpoint. D: Frequency Reference Bias 2 (FBIAS2) 100% = Maximum output frequency (E1-04). Total bias = Internal bias (H3-03) + FBIAS (H3-07) + A3 input level E: Motor Temperature See parameters L1-03 & L1-04. 10: FWD Torque Limit (Quadrant 1) 100% = Motor rated torque. 11: REV Torque Limit (Quadrant 3) 100% = Motor rated torque. 12: Regenerative Torque Limit (Quadrants 2 and 4) 100% = Motor rated torque. 13: Torque Reference (in Torque Control); Torque Limit (in Speed Control) (Quadrants 1, 2, 3, 4) 100% = Motor rated torque. 14: Torque Compensation 100% = Motor rated torque. 15: FWD / REV Torque Limit (Quadrants 1 and 3) 100% = Motor rated torque. 1F: Not Used 0 to 1F 2 A A A A Denotes that parameter can be changed when the Drive is running. Note: Some analog inputs are control method dependent. Parameters A - 27 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0.0 to 1000.0 100.0% A A A A –100.0 to +100.0 0.0% A A A A H3-06 Terminal A3 Gain Setting Terminal A3 Gain H3-07 Terminal A3 Bias Setting Terminal A3 Bias Sets the frequency reference when 0V is input. H3-08 Terminal A2 Signal Level Selection Term A2 Signal Selects the signal level of terminal A2. 0: 0 to 10Vdc (switch S1-2 must be in the OFF position). 1: -10 to +10Vdc (switch S1-2 must be in the OFF position). 2: 4 to 20mA (switch S1-2 must be in the ON position) 0 to 2 2 A A A A H3-09 Terminal A2 Function Selection Terminal A2 Sel Selects the function of terminal A2. Same choices as Terminal A3 Function Selection (H3-05). 0 to 1F 0 A A A A H3-10 Terminal A2 Gain Setting Terminal A2 Gain Sets the output level when 10V is input. 0.0 to 1000.0 100.0% A A A A H3-11 Terminal A2 Bias Setting Terminal A2 Bias Sets the output level when 0V is input. –100.0 to +100.0 0.0% A A A A Analog Input Filter Time Constant Filter Avg Time This parameter adjusts the filter on all 3 analog inputs. Increase to add stability, decrease to improve response. 0.00 to 2.00 0.03sec A A A A Terminal FM Monitor Selection Terminal FM Sel Selects which monitor will be output on terminals FM and FC. 1: Frequency Reference 100% = Maximum output frequency E1-04. 2: Output Frequency 100% = Maximum output frequency E1-04. 3: Output Current 100% = Drive rated current. 5: Motor Speed 100% = Maximum output frequency E1-04. 6: Output Voltage 100% = 200/400Vac depending on Drive voltage rating. 7: DC Bus Voltage 100% = 400/800Vdc depending on Drive voltage rating. 8: Output kWatts 100% = Drive rated power. 9: Torque Reference 100% = Motor rated torque. 15:Terminal A1 Input Level 100% = 10Vdc 16:Terminal A2 Input Level 100% = 10Vdc or 20mA 17:Terminal A3 Input Level 100% = 10Vdc 18:Motor Secondary Current 100% = Motor rated secondary current. 19:Motor Excitation Current 100% = Motor rated magnetizing current. 20:SFS Output 100% = Maximum output frequency E1-04. 21:ASR Input 100% = Maximum output frequency E1-04. 22:ASR Output 100% = Maximum output frequency E1-04. 24:PID Feedback 100% = Maximum output frequency E1-04. 26:Output Voltage Reference Vq 100% = E1-05, default 240V or 480V. 27:Output Voltage Reference Vd 100% = E1-05, default 240V or 480V. 31:Not Used 32:ACR q Output (100% = Motor rated secondary current) 33:ACR d Output (100% = Motor rated magnetizing current) 36:PID Input 100% = Maximum output frequency E1-04. 37:PID Output 100% = Maximum output frequency E1-04. 38:PID Setpoint 100% = Maximum output frequency E1-04. 44:ASR Output Without Filter 45:Feedforward Control Output 100% = Motor rated secondary current. 1 to 45 2 A A A A H3-12 Sets the output level when 10V is input. Analog Outputs H4-01 Denotes that parameter can be changed when the Drive is running. Parameters A - 28 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0.0 to 1000.0 100.0% Q Q Q Q –110.0 to 110.0 0.0% A A A A H4-02 Terminal FM Gain Setting Terminal FM Gain Sets terminal FM output level when selected monitor is at 100%. H4-03 Terminal FM Bias Setting Terminal FM Bias Sets terminal FM output level when selected monitor is at 0%. Terminal AM Monitor Selection Terminal AM Sel Selects which monitor will be the output on terminals AM and FC. Same function choices as H4-01. 1 to 45 3 A A A A H4-05 Terminal AM Gain Setting Terminal AM Gain Sets terminal AM output voltage (in percent of 10Vdc) when selected monitor is at 100% output. 0.0 to 1000.0 50.0% Q Q Q Q H4-06 Terminal AM Bias Setting Terminal AM Bias Sets terminal AM output voltage (in percent of 10Vdc) when selected monitor is at 0% output. –110.0 to 110.0 0.0% A A A A H4-07 Terminal FM Signal Level Selection FM Level Select 1 Selects the signal level of terminal FM. 0: 0 to 10Vdc 1: -10 to +10Vdc 2: 4 to 20mA* 0 or 2 0 A A A A H4-08 Terminal AM Signal Level Selection AM Level Select 2 Selects the signal level of terminal AM. 0: 0 to 10Vdc 1: -10 to +10Vdc 2: 4 to 20mA* 0 or 2 0 A A A A Drive Node Address Serial Comm Adr Selects Drive station node number (address) for Modbus terminals R+, R-, S+, S-. The Drive’s power must be cycled for the setting to take effect. 0 to 20 Hex 1F A A A A H5-02 Communication Speed Selection Serial Baud Rate Selects the baud rate for Modbus terminals R+, R-, S+ and S-. The Drive’s power must be cycled for the setting to take effect. 0: 1200 bps 1: 2400 bps 2: 4800 bps 3: 9600 bps 4: 19200 bps 0 to 4 3 A A A A H5-03 Communication Parity Selection Serial Com Sel Selects the communication parity for Modbus terminals R+, R-, S+ and S-. The Drive’s power must be cycled for the setting to take effect. 0: No Parity 1: Even Parity 2: Odd Parity 0 to 2 0 A A A A H5-04 Stopping Method After Communication Error Serial Fault Sel Selects the stopping method when a communication timeout fault (CE) is detected. 0: Ramp to Stop 1: Coast to Stop 2: Fast-Stop 3: Alarm Only 0 to 3 3 A A A A H5-05 Communication Fault Detection Selection Serial Flt Dtct Enables or disables the communications timeout fault (CE). 0: Disabled - A communication loss will not cause a communication fault. 1: Enabled - If communication is lost for more than 2 seconds, a CE fault will occur. 0 to 1 1 A A A A H5-06 Drive Transmit Wait Time Transmit WaitTIM Set the delay time from when the Drive receives data to when the Drive sends data. 5 to 65 5ms A A A A H5-07 RTS Control Selection RTS Control Sel Enables or disables “request to send” (RTS) control: 0: Disabled - RTS is always on 1: Enabled - RTS turns on only when sending 0 to 1 1 A A A A Unit Selection for MEMOBUS Register 0025H MEMOBUS 25H UNIT Selects the units used for MEMOBUS registry 0025H (monitors the output voltage reference). 0: 0.1 V units 1: 1 V units 0, 1 0 A A A A Terminal RP Pulse Train Input Function Selection Pulse Input Sel Selects the function of pulse train terminal RP. 0: Frequency reference 1: PID feedback value 2: PID setpoint value 0 to 2 0 A A A A H6-02 Pulse Train Input Scaling Pulse In Scaling Sets the number of pulses (in Hz) that is equal to the maximum output frequency E1-04. 1000 to 32000 1440Hz A A A A H6-03 Pulse Train Input Gain Pulse Input Gain Sets the output level when the pulse train input is at 100% as a percentage of maximum output frequency E1-04. 0.0 to 1000.0 100.0% A A A A H4-04 Serial Communications Setup H5-01 H5-10 <3021> Pulse I/O Setup H6-01 Denotes that parameter can be changed when the Drive is running. Note: Some digital outputs are control method dependent. Parameters A - 29 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector -100.0 to 100.0 0.0% A A A A H6-04 Pulse Train Input Bias Pulse Input Bias Sets the output level when the pulse train input is 0Hz as a percentage of maximum output frequency E1-04. H6-05 Pulse Train Input Filter Time Pulse In Filter Sets the pulse train input filter time constant in seconds. 0.00 to 2.00 0.10sec A A A A Terminal MP Pulse Train Monitor Selection Pulse Moni Sel Select the pulse train monitor output terminal MP function (value of the part of U1). See Table A2 for the list of U1 monitors. 1, 2, 5, 20, 24, 31, 36 2 A A A A Pulse Train Monitor Scaling Pulse Moni Scale Sets the number of output pulses when the monitor is 100% (in Hz). Set H6-06 to 2, and H6-07 to 0, to make the pulse train monitor output synchronous to the output frequency. 0 to 32000 1440Hz A A A A L1-01 Motor Overload Protection Selection MOL Fault Select Sets the motor thermal overload protection (OL1) based on the cooling capacity of the motor. 0: Disabled 1: Standard Fan Cooled (< 10:1 motor) 2: Standard Blower Cooled (≥ 10:1 motor) 3: Vector Motor (≤ 1000:1 motor) 0 to 3 1 Q Q Q Q L1-02 Motor Overload Protection Time MOL Time Const Sets the motor thermal overload protection (OL1) time. A larger L1-02 time will increase the time before an OL1 fault will occur. 0.1 to 20.0 8.0min A A A A L1-03 Motor Overheat Alarm Operation Selection Mtr OH Alarm Sel Sets operation selection when the motor temperature analog input (H3-09 = E) exceeds the OH3 alarm level (1.17V) 0: Ramp to Stop 1: Coast to Stop 2: Fast-Stop 3: Alarm Only 0 to 3 3 A A A A L1-04 Motor Overheat Fault Operation Selection Mtr OH Fault Sel Sets stopping method when the motor temperature analog input (H3-09 = E) exceeds the OH4 fault level (2.34V). 0: Ramp to Stop 1: Coast to Stop 2: Fast-Stop 0 to 2 1 A A A A L1-05 Motor Temperature Input Filter Time Mtr Temp Filter This parameter adjusts the filter on the motor temperature analog input (H3-09 = E). Increase to add stability, decrease to improve response. 0.00 to 10.00 0.20sec A A A A L2-01 Momentary Power Loss Detection Selection PwrL Selection Enables and disables the momentary power loss function. 0: Disabled - Drive trips on (UV1) fault when power is lost. 1: Power Loss Ride Thru Time - Drive will restart if power returns within the time set in L2-02.* 2: CPU Power Active - Drive will restart if power returns prior to control power supply shut down.* * In order for a restart to occur, the run command must be maintained throughout the ride thru period. 0 to 2 0 A A A A L2-02 Momentary Power Loss Ridethru Time PwrL Ridethru t Sets the power loss ride-thru time. This value is dependent on the capacity of the Drive. Only effective when L2-01 = 1. 0.0 to 25.5sec Varies by kVA A A A A L2-03 Momentary Power Loss Minimum Base Block Time PwrL Baseblock t Sets the minimum time to wait to allow the residual motor voltage to decay before the Drive output turns back on during power loss ride thru. After a power loss, if L2-03 is greater than L2-02, operation resumes after the time set in L2-03. 0.1 to 5.0sec Varies by kVA A A A A L2-04 Momentary Power Loss Voltage Recovery Ramp Time PwrL V/F Ramp t Sets the time it takes the output voltage to return to the preset V/F pattern after speed search (current detection mode) is complete. 0.0 to 5.0sec Varies by kVA A A A A Sets the Drive's DC Bus undervoltage trip level. If this is set lower than the factory setting, additional AC input reactance or DC bus reactance may be necessary. Consult the factory before changing this parameter setting. 150 to 210 190 Vdc (230V) L2-05 Undervoltage Detection Level PUV Det Level A A A A 300 to 420 380 Vdc (480V) L2-06 KEB Deceleration Rate KEB Decel Time Sets the time required to decelerate to zero speed when a KEB command is input from a multi-function input. 0.0 to 200.0 0.0sec A A A A L2-07 Momentary Recovery Time UV Return Time Set the time (in seconds) to accelerate to the set speed after recovery from a momentary power loss. If setting = 0.0, then active acceleration time is used instead. 0.0 to 25.5 0.0sec A A A A H6-06 H6-07 Motor Overload Power Loss Ridethru Denotes that parameter can be changed when the Drive is running. Parameters A - 30 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector L2-08 Frequency Reduction Gain at KEB Start KEB Frequency Sets the percentage of output frequency reduction at the beginning of deceleration when a KEB command is input from multi-function input. Reduction = slip frequency before KEB operation × L2-08 × 2 0 to 300 100% A A A A L3-01 Stall Prevention Selection During Accel StallP Accel Sel Selects the stall prevention method used to prevent excessive current during acceleration. 0: Disabled - Motor accelerates at active acceleration rate. The motor may stall if load is too heavy or accel time is too short. 1: General Purpose - When output current exceeds L3-02 level, acceleration stops. Acceleration will continue when the output current level falls below the L3-02 level. 2: Intelligent - The active acceleration rate is ignored. Acceleration is completed in the shortest amount of time without exceeding the current value set in L3-02. 0 to 2 1 A A A - L3-02 Stall Prevention Level During Acceleration StallP Accel Lvl This function is enabled when L3-01 is “1” or “2”. Drive rated current is 100%. Decrease the set value if stalling or excessive current occurs with factory setting. 0 to 200 Varies by Duty Rating* A A A - L3-03 Stall Prevention Limit During Acceleration StallP CHP Lvl Sets the lower limit for stall prevention during acceleration, as a percentage of the Drive’s rated current, when operation is in the frequency range above E1-06 (constant power region). 0 to 100 50% A A A - Stall Prevention Selection During Deceleration StallP Decel Sel When using a braking resistor, use setting “0”. Setting “3” is used in specific applications. 0: Disabled - The Drive decelerates at the active deceleration rate. If the load is too large or the deceleration time is too short, an OV fault may occur. 1: General Purpose - The Drive decelerates at the active deceleration rate, but if the main circuit DC bus voltage reaches the stall prevention level (380/760Vdc), deceleration will stop. Deceleration will continue once the DC bus level drops below the stall prevention level. 2: Intelligent - The active deceleration rate is ignored and the Drive decelerates as fast as possible w/o hitting OV fault level. Range: C1-02 / 10. 3: Stall Prevention w/ Braking Resistor - Stall prevention during deceleration is enabled in coordination with dynamic braking. (Not available in Flux Vector) 0 to 3 1 Q Q Q Q L3-05 Stall Prevention Selection During Running StallP Run Sel Selects the stall prevention method to use to prevent Drive faults during run. 0: Disabled - Drive runs a set frequency. A heavy load may cause the Drive to trip on an OC or OL fault. 1: Decel Time 1 - In order to avoid stalling during heavy loading, the Drive will decelerate at Decel time 1 (C1-02) if the output current exceeds the level set by L3-06. Once the current level drops below the L3-06 level, the Drive will accelerate back to its frequency reference at the active acceleration rate. 2: Decel Time 2 - Same as setting 1 except the Drive decelerates at Decel Time 2 (C1-04). When output frequency is 6Hz or less, stall prevention during running is disabled regardless of L3-05 setting. 0 to 2 1 A A - - L3-06 Stall Prevention Level During Running StallP Run Level This parameter is enabled when L3-05 is set to “1” or “2”. Drive rated current is set as 100%. Decrease the set value if stalling or excessive current occurs with factory setting. 30 to 200 Varies by Duty Rating* A A - - L3-11 OV Suppression Function Selection OV Inhibit Sel Enables or disables OV suppression function, which allows the Drive to change the output frequency as the load changes, to prevent OV fault. 0: Disabled 1: Enabled 0 to 1 0 - - A A 380V or 760V - - A A Stall Prevention L3-04 L3-12 OV Suppression Function Voltage Level OV Inhbt VoltLvl Sets the DC bus voltage level at which the OV suppression function is active. 350 to 390 (240V) 700 to 780 (480V) Denotes that parameter can be changed when the Drive is running. * For Heavy Duty (HD) Rating: Factory Setting=150%. For Normal Duty (ND) Rating: Factory Setting=120%. The setting value will change automatically if the carrier frequency is set larger than the default setting. Parameters A - 31 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector Varies by Duty Rating*1 0.0Hz A A A A 0.0 to 20.0 2.0Hz A A A A Varies by Duty Rating*2 0.0Hz A A A A 0.0 to 20.0 2.0Hz A A A A 0 to 1 0 A A A A 0 to 100.0 80.0% A A A A Reference Detection L4-01 Speed Agreement Detection Level Spd Agree Level L4-02 Speed Agreement Detection Width Spd Agree Width L4-03 Speed Agreement Detection Level (+/-) Spd Agree Lvl +- L4-04 Speed Agreement Detection Width (+/-) Spd Agree Wdth +- These parameters configure the multi-function output (H2) settings “Fref/Fout agree 1”, “Fref/Set agree 1”, “Frequency detection 1,” and “Frequency detection 2". Parameter L4-01 sets the level while parameter L4-02 sets the hysteresis for the speed detection output function. These parameters configure the multi-function output (H2) settings “Fref/Fout agree 2”, “Fref/Set agree 2”, “Frequency detection 3,” or “Frequency detection 4". Parameter L4-03 sets the level while parameter L4-04 sets the hysteresis for the speed detection output function. L4-05 Frequency Reference Loss Detection Selection Ref Loss Sel Determines how the Drive will react when the frequency reference is lost. The frequency reference is considered lost when reference drops 90% or more of its current value in less than 400ms. 0: Stop - Drive will stop. 1: Run at L4-06 PrevRef - Drive will run at the percentage set in L4-06 of the frequency reference level at the time frequency reference was lost. L4-06 Frequency Reference Level at Loss Frequency Fref at Floss If the frequency reference loss function is enabled (L4-05=1) and frequency reference is lost, the Drive will run at a reduced frequency reference determined by the following formula: Fref = Fref at time of loss * L4-06. L5-01 Number of Auto Restart Attempts Num of Restarts Sets the counter for the number of times the Drive will perform an automatic restart on the following faults: GF, LF, OC, OV, PF, PUF, RH, RR, OL1, OL2, OL3, OL4, UV1. Auto restart will check to see if the fault has cleared every 5ms. When no fault is present, the Drive will attempt an auto restart. If the Drive faults after an auto restart attempt, the counter is incremented. When the Drive operates without fault for 10 minutes, the counter will reset to the value set in L5-01. 0 to 10 0 A A A A L5-02 Auto Restart Operation Selection Restart Sel Determines if the fault contact activates during an automatic restart attempt. 0: No Fault Relay - fault contact will not activate during an automatic restart attempt. 1: Fault Relay Active - fault contact will activate during an automatic restart attempt. 0 to 1 0 A A A A Torque Detection Selection 1 Torq Det 1 Sel Determines the Drive's response to an Overtorque/Undertorque condition. Overtorque and Undertorque are determined by the settings in parameters L6-02 and L6-03. The multi-function output settings “B” and “17” in the H2parameter group are also active if programmed. 0: Disabled 1: OL3 at Speed Agree - Alarm (Overtorque Detection only active during Speed Agree and Operation continues after detection). 2: OL3 at RUN - Alarm (Overtorque Detection is always active and operation continues after detection). 3: OL3 at Speed Agree - Fault (Overtorque Detection only active during Speed Agree and Drive output will shut down on an OL3 fault). 4: OL3 at RUN - Fault (Overtorque Detection is always active and Drive output will shut down on an OL3 fault). 5: UL3 at Speed Agree - Alarm (Undertorque Detection is only active during Speed Agree and operation continues after detection). 6: UL3 at RUN - Alarm (Undertorque Detection is always active and operation continues after detection). 7: UL3 at Speed Agree - Fault (Undertorque Detection only active during Speed Agree and Drive output will shut down on an OL3 fault). 8: UL3 at RUN - Fault (Undertorque Detection is always active and Drive output will shut down on an OL3 fault). 0 to 8 0 A A A A Fault Restart Torque Detection L6-01 Denotes that parameter can be changed when the Drive is running. *1 For Heavy Duty (HD) Rating: Setting Range=0.0 to 300.0. For Normal Duty (ND) Rating: Setting Range=0.0 to 400.0. *2 For Heavy Duty (HD) Rating: Setting Range= -300.0 to 300.0. For Normal Duty (ND) Rating: Setting Range= -400.0 to 400.0. Parameters A - 32 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector L6-02 Torque Detection Level 1 Torq Det 1 Lvl Sets the Overtorque/Undertorque detection level as a percentage of Drive rated current or torque for torque detection 1. Current detection for A1-02 = 0 or 1. Torque detection for A1-02 = 2 or 3. 0 to 300 150% A A A A L6-03 Torque Detection Time 1 Torq Det 1 Time Sets the length of time an Overtorque/Undertorque condition must exist before torque detection 1 recognized by the Drive. 0.0 to 10.0 0.1sec A A A A L6-04 Torque Detection Selection 2 Torq Det 2 Sel Determines the Drive's response to an Overtorque/Undertorque condition. Overtorque and Undertorque are determined by the settings in parameters L6-05 and L6-06. The multi-function output settings “18” and “19” in the H2parameter group are also active if programmed. 0: Disabled 1: OL4 at Speed Agree - Alarm (Overtorque Detection only active during Speed Agree and Operation continues after detection). 2: OL4 at RUN - Alarm (Overtorque Detection is always active and operation continues after detection). 3: OL4 at Speed Agree - Fault (Overtorque Detection only active during Speed Agree and Drive output will shut down on an OL4 fault). 4: OL4 at RUN - Fault (Overtorque Detection is always active and Drive output will shut down on an OL4 fault). 5: UL4 at Speed Agree - Alarm (Undertorque Detection is only active during Speed Agree and operation continues after detection). 6: UL4 at RUN - Alarm (Undertorque Detection is always active and operation continues after detection). 7: UL4 at Speed Agree - Fault (Undertorque Detection only active during Speed Agree and Drive output will shut down on an OL4 fault). 8: UL4 at RUN - Fault (Undertorque Detection is always active and Drive output will shut down on an OL4 fault). 0 to 8 0 A A A A L6-05 Torque Detection Level 2 Torq Det 2 Lvl Sets the Overtorque/Undertorque detection level as a percentage of Drive rated current or torque for torque detection 2. Current detection for A1-02 = 0 or 1. Torque detection for A1-02 = 2 or 3. 0 to 300 150% A A A A L6-06 Torque Detection Time 2 Torq Det 2 Time Sets the length of time an Overtorque/Undertorque condition must exist before torque detection 2 is recognized by the Drive. 0.0 to 10.0 0.1sec A A A A L7-01 Forward Torque Limit Torq Limit Fwd Sets the torque limit value as a percentage of the motor rated torque. Four individual quadrants can be set. 0 to 300 200% - - A A L7-02 Reverse Torque Limit Torq Limit Rev 0 to 300 200% - - A A L7-03 Forward Regenerative Torque Limit Torq Lmt Fwd Rgn 0 to 300 200% - - A A 0 to 300 200% - - A A 0 to 1 0 A A A A Torque Limit L7-04 Output torque Positive torque No. of motor rotations Regen. state Reverse Regen. state Reverse Regenerative Torque Limit Torq Lmt Rev Rgn Forward Negative torque Hardware Protection L8-01 Internal Dynamic Braking Resistor Protection Selection DB Resistor Prot Selects the DB protection only when using 3% duty cycle heatsink mount Yaskawa braking resistor. This parameter does not enable or disable the DB function of the Drive. 0: Not Provided 1: Provided L8-02 Overheat Alarm Level OH Pre-Alarm Lvl When the cooling fin temperature exceeds the value set in this parameter, an overheat alarm (OH) will occur. 50 to 130 Varies by kVA A A A A L8-03 Overheat Pre-Alarm Operation Selection OH Pre-Alarm Sel Selects the Drive operation upon an OH pre-alarm detection. 0: Ramp to Stop 1: Coast to Stop 2: Fast-Stop 3: Alarm Only 0 to 3 3 A A A A L8-05 Input Phase Loss Protection Selection Ph Loss In Sel Selects the detection of input current phase loss, power supply voltage imbalance, or main circuit electrostatic capacitor deterioration. 0: Disabled 1: Enabled 0 to 1 1 A A A A Denotes that parameter can be changed when the Drive is running. Parameters A - 33 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0 to 1 1 A A A A L8-07 Output Phase Loss Protection Ph Loss Out Sel Selects the detection of output current open-phase. When applied motor capacity is too small for Drive capacity, output phase loss may be detected inadvertently. In this case, set to 0. 0: Disabled 1: 1-phase Loss Detection 2: 2/3-phase Loss Detection L8-09 Output Ground Fault Detection Selection Ground Fault Sel Enables and disables the Drive’s output ground fault detection. 0: Disabled 1: Enabled 0 to 1 1 A A A A L8-10 Heatsink Cooling Fan Operation Selection Fan On/Off Sel Controls the heatsink cooling fan operation. 0: Fan On-Run Mode - Fan will operate only when the Drive is running and for L8-11 seconds after RUN is removed. 1: Fan Always On - Cooling fan operates whenever the Drive is powered up.) 0 to 1 0 A A A A L8-11 Heatsink Cooling Fan Operation Delay Time Fan Delay Time This parameter sets the delay time for the cooling fan turn off after the run command is removed when L8-10 = 0. 0 to 300 60sec A A A A L8-12 Ambient Temperature Setting Ambient Temp When the Drive is installed in an ambient temperature exceeding its rating, the Drive overload (OL2) protection level is adjusted. 45 to 60 45°C A A A A L8-15 OL2 Characteristic Selection at Low Speeds OL2 Sel @ L-Spd This parameter assists in protecting the output transistors from overheating when output current is high and output frequency is low (6Hz and less). 0: Disabled 1: Enabled (L8-18 is active) 0 to 1 0 A A A A L8-18 Soft CLA Selection Soft CLA Sel Enables and disables the software current limit function. Consult the factory before disabling. 0: Disabled 1: Enabled 0 to 1 1 A A A A Cooling Fan OH1 Detection OH1 Detect Sel 0: Disabled (FAN minor fault detection) 1: Enabled (OH1 major fault detection) 0, 1 1 A A A A n1-01 Hunting Prevention Selection Hunt Prev Select If the motor vibrates while lightly loaded, hunting prevention may reduce the vibration. 0: Disabled 1: Enabled 0 to 1 1 A A - - n1-02 Hunting Prevention Gain Setting Hunt Prev Gain Sets the gain for the Hunting Prevention Function. If the motor vibrates while lightly loaded and n1-01=1, increase the gain by 0.1 until vibration ceases. If the motor stalls while n1-01=1, decrease the gain by 0.1 until the stalling ceases. 0.00 to 2.50 1.00 A A - - 0.00 to 10.00 1.00 - - A - L8-32 <3021> Hunting Prevention AFR Tuning n2-01 Speed Feedback Detection Control (AFR) Gain AFR Gain Sets the internal speed feedback detection control gain in the automatic frequency regulator (AFR). Normally, there is no need to change this setting. Adjust this parameter as follows: • If hunting occurs, increase the set value. • If response is low, decrease the set value. Adjust the setting by 0.05 units at a time, while checking the response. n2-02 Speed Feedback Detection Control (AFR) Time Constant AFR Time Sets the time constant to control the rate of change in the speed feedback detection control. 0 to 2000 50ms - - A - n2-03 Speed Feedback Detection Control (AFR) Time Constant 2 AFR Time 2 Sets the time constant to control the amount of change in the speed at low speed. 0 to 2000 750ms - - A - Denotes that parameter can be changed when the Drive is running. Parameters A - 34 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector High Slip Braking n3-01 High Slip Braking Deceleration Frequency Width HSB Decel Width Sets how aggressively the Drive decreases the output frequency as it stops the motor using high slip braking (HSB). If Overvoltage (OV) faults occur during HSB, this parameter may need to be increased. 1 to 20 5% A A - - n3-02 High Slip Braking Current Limit HSB Current Ref Sets the maximum current to be drawn during an HSB stop. Higher n3-02 settings will shorten motor stopping times but cause increased motor current, and therefore increased motor heating. 100 to 200 150% A A - - n3-03 High Slip Braking Dwell Time at Stop HSB DwelTim@ Stp Sets the amount of time the Drive will dwell at E1-09 (Minimum Frequency) at the end of deceleration. If this time is set too low, the machine inertia can cause the motor to rotate slightly after the HSB stop is complete and the Drive output is shut off. 0.0 to 10.0 1.0sec A A - - n3-04 High Slip Braking Overload Time HSB OL Time Sets the time required for an HSB overload fault (OL7) to occur when the Drive output frequency does not change for some reason during an HSB stop. Normally this does not need to be adjusted. 30 to 1200 40sec A A - - Monitor Select o1-01 o1-02 o1-03 User Monitor Selection User Monitor Sel Selects which monitor will be displayed in the operation menu upon power-up when o1-02 = 4. 4 to 45 6 A A A A User Monitor Selection After Power-Up Power-On Monitor Selects which monitor will be displayed upon power-up. 1: Frequency Reference (U1-01) 2: Output Frequency (U1-02) 3: Output Current (U1-03) 4: User Monitor (set by o1-01) 1 to 4 1 A A A A 0 to 39999 0 A A A A Digital Operator Display Selection Display Scaling Sets the units of the Frequency References (d1-01 to d1-17), the Frequency Reference Monitors (U1-01, U1-02, U1-05), and the Modbus communication frequency reference. 0: Hz 1: % (100% = E1-04) 2 to 39: RPM (Enter the number of motor poles). 40 to 39999: User display. Set the number desired at maximum output frequency. 4 digit number Number of digits from the right of the decimal point Example 1: o1-03 = 12000, will result in frequency reference from 0.0 to 200.0 (200.0 = Fmax). Example 2: o1-03 = 21234, will result in frequency reference from 0.00 to 12.34 (12.34 = Fmax). o1-04 Setting unit for frequency parameters related to V/F characteristics Display Units Sets the setting units related to V/F pattern frequency related parameters (E1-04, -06, -09, -11) 0: Hertz 1: RPM 0 to 1 0 - - - A o1-05 LCD Brightness Adjustment LCD Contrast Sets the contrast of the Digital Operator LCD. A setting of “1” is the lightest contrast and a setting of “5” is the darkest contrast. 0 to 5 3 A A A A Denotes that parameter can be changed when the Drive is running. Parameters A - 35 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector Key Selections o2-01 Local/Remote Key Function Selection Local/Remote Key Determines if the Digital Operator Local/Remote key is functional. 0: Disabled 1: Enabled 0 to 1 1 A A A A o2-02 STOP Key Function Selection Oper STOP Key Determines if the STOP key on the Digital Operator will stop the Drive when Drive is operating from external terminals or serial communication. 0: Disabled 1: Enabled 0 to 1 1 A A A A o2-03 User Parameter Default Value User Defaults Allows storing of parameter settings as a User Initialization Selection. 0: No Change 1: Set Defaults - Saves current parameter settings as user initialization. A1-03 now allows selecting <1110> for user initialization and returns o2-03 to zero. 2: Clear All - Clears the currently saved user initialization. A1-03 no longer allows selecting <1110> and returns o2-03 to zero. 0 to 2 0 A A A A o2-04 Drive/kVA Selection Inverter Model # Sets the kVA of the Drive. Enter the number based on Drive model number. Use the last four digits of the model number. CIMR-F7U . This parameter only needs to be set when installing a new control board. Do not change for any other reason. Refer to Table B.1. 0 to FF Varies by kVA A A A A o2-05 Frequency Reference Setting Method Selection Operator M.O.P. Determines if the Data/Enter key must be used to input a frequency reference from the Digital Operator. 0: Disabled - Data/Enter key must be pressed to enter a frequency reference. 1: Enabled - Data/Enter key is not required. The frequency reference is adjusted by the up and down arrow keys on the Digital Operator without having to press the data/enter key. 0 to 1 0 A A A A o2-06 Operation Selection when Digital Operator is Disconnected Oper Detection Determines if the Drive will stop when the Digital Operator is removed when in LOCAL mode or b1-02=0. 0: Disabled - The Drive will not stop when the Digital Operator is removed. 1: Enabled - The Drive will fault (OPR) and coast to stop when the Digital Operator is removed. 0 to 1 1 A A A A o2-07 Cumulative Operation Time Setting Elapsed Time Set Sets the initial value of the elapsed operation timer U1-13. 0 to 65535 0H A A A A o2-08 Cumulative Operation Time Selection Elapsed Time Run Sets how time is accumulated for the elapsed operation timer U1-13. 0: Power-On Time - Time accumulates when the Drive is powered. 1: Running Time - Time accumulates only when the Drive is running. 0 to 1 0 A A A A 1 1 A A A A Determines parameter default values after a Drive initialization (A1-03) is executed. This should always be set to "1" for North American installations. 1: American spec o2-09 Initialization Specification Selection Init Mode Sel WARNING Possible damage to equipment or injury may occur if this setting is changed from “1: American Spec.” O2-09 is a macro parameter that can change the default values of terminal I/O and many other parameters in the drive. Consult the Yaskawa factory for details if adjustment is required. o2-10 Cumulative Cooling Fan Operation Time Setting Fan ON Time Set Sets the initial value of the heatsink fan operation time monitor U1-40. 0 to 65535 0H A A A A o2-12 Fault Trace/Fault History Clear Function FLT Trace Init Clears the fault memory contained in the U2 and U3 monitors. 0: Disabled - no effect 1: Enabled - resets U2 and U3 monitors, and returns o2-12 to zero. 0 to 1 0 A A A A o2-14 kWh User Monitor Initialization kWH MonitorClear Used to reset the kilowatt-hour monitor U1-29 to zero. 0: Disabled - no change 1: Enabled - Resets U1-29 to zero and returns o2-14 to zero. 0 to 1 0 A A A A Denotes that parameter can be changed when the Drive is running. Parameters A - 36 Table A.1 F7 Parameter List (Continued) Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting V/F V/F w/PG Open Loop Vector Flux Vector 0 to 3 0 A A A A 0 to 1 0 A A A A 1, 2 1 A A A A COPY Function This parameter controls the copying of parameters to and from the Digital Operator. 0: COPY SELECT (no function) o3-01 Copy Function Selection Copy Function Sel 1: INV -> OP READ - All parameters are copied from the Drive to the Digital Operator. 2: OP -> INV WRITE - All parameters are copied from the Digital Operator to the Drive. 3: OP<-->INV VERIFY - Parameter settings in the Drive are compared to those in the Digital Operator. NOTE: When using the copy function, the Drive model number (o2-04), software number (U1-14), and control method (A1-02) must match or an error will occur. o3-02 Copy Allowed Selection Read Allowable Enables and disables the Digital Operator copy functions. 0: Disabled - No Digital Operator copy functions are allowed. 1: Enabled - Copying allowed. Auto-Tuning T1-00 Motor Selection 1 / 2 Select Motor Selects which set of motor parameters are to be used and set during Auto-Tuning. If Motor 2 selection (H1-XX=16) is not selected, this parameter will not be displayed. 1: 1st Motor - E1 to E2 2: 2nd Motor - E3 to E4 T1-01 Auto-Tuning mode selection Tuning Mode Sel Selects the Auto-Tuning mode. 0: Rotational Auto-Tuning (A1-02 = 2 or 3) 1: Stationary Auto-Tuning (A1-02 = 2 or 3) 2: Terminal resistance only, (stationary) Auto-Tuning (A1-02 = 0, 1, 2, or 3) 0 to 2 0 A A A A T1-02 Motor Rated Power Mtr Rated Power Set the motor rated power in kilowatts (kW). NOTE:If motor power is given in horsepower, power in kW can be calculated using the following formula: kW = Hp * 0.746 0.00 to 650.00 kW Varies by kVA A A A A 230Vac or 460Vac - - A A 0.0 to 255.0 (240V) Motor rated voltage Rated Voltage Set the motor rated voltage in Volts (V). T1-04 Motor Rated Current Rated Current Set the motor rated current in Amperes (A). Varies by kVA Varies by kVA A A A A T1-05 Motor Base Frequency Rated Frequency Set the base frequency of the motor in Hertz (Hz). Varies by Duty Rating* 60.0Hz - - A A T1-06 Number of Motor Poles Number of Poles Set the number of motor poles. 2 to 48 4 poles - - A A T1-07 Motor Base Speed Rated Speed Set the base speed of the motor in revolutions per minute (RPM). 0 to 24000 1750 RPM - - A A T1-08 Number of PG Pulses PG Pulses / Rev Set the number of pulses per revolution (PPR) for the encoder (pulse generator) being used without any multiplication factor. 0 to 60000 1024 PPR - - - A T1-03 0.0 to 510.0 (480V) Denotes that parameter can be changed when the Drive is running. * For Heavy Duty (HD) Rating: Setting Range=0.0 to 300.0. For Normal Duty (ND) Rating: Setting Range=0.0 to 400.0. Parameters A - 37 F7 Monitor List Table A.2 F7 Monitor List Parameter No. Parameter Name Digital Operator Display Description Display Units Monitor U1-01 U1-02 U1-03 U1-04 U1-05 U1-06 U1-07 U1-08 U1-09 Frequency Reference Frequency Ref Output Frequency Output Freq Output Current Output Current Control Method Control Method Motor Speed Motor Speed Output Voltage Output Voltage DC Bus Voltage DC Bus Voltage Output Power Output kWatts Torque Reference Torque Reference Frequency reference (speed command) monitor when in REMOTE mode, frequency reference (speed command) setting location when in local mode or b1-01 = 0. Set by o1-03. Output frequency Set by o1-03. Output current 0.01A Control method set in A1-02. 0 = V/F without PG 1 = V/F with PG 2 = Open Loop Vector 3 = Flux Vector - Motor speed feedback Set by o1-03. Output voltage 0.1Vac DC Bus Voltage 1Vdc Output power 0.1kW Torque reference 0.1% Input terminal status 0 0 0 0 0 0 0 0 U1-10 1: FWD. run (Terminal S1) is ON. 1: REV. run (Terminal S2) is ON. 1: Multi-function input 1 (Terminal S3) is ON. 1: Multi-function input 2 (Terminal S4) is ON. 1: Multi-function input 3 (Terminal S5) is ON. 1: Multi-function input 4 (Terminal S6) is ON. 1: Multi-function input 5 (Terminal S7) is ON. 1: Multi-function input 6 (Terminal S8) is ON. Input Terminal Status Input Term Sts - Output terminal status. 0 0 0 0 0 0 0 0 1: Multi-function Output 1 (Terminal M1-M2) is ON. U1-11 Output Terminal Status Output Term Sts 1: Multi-function Output 2 (Terminal M3-M4) is ON. 1: Multi-function Output 3 (Terminal M5-M6) is ON. 0: Not used 1: Fault output (Terminal MA-MB-MC) is ON. Parameters A - 38 - Table A.2 F7 Monitor List (Continued) Parameter No. Parameter Name Digital Operator Display Description Display Units Internal Drive status 0 0 0 0 0 0 0 0 1: During running 1: During zero speed 1: During reverse 1: During reset signal input U1-12 Drive Operation Status Int Ctl Sts 1 1: During speed agree - 1: Drive operation ready 1: During fault detection (Minor fault) 1: During fault detection (Major fault) U1-13 U1-14 U1-15 U1-16 U1-17 U1-18 U1-19 U1-20 U1-21 U1-22 U1-24 U1-25 U1-26 U1-27 U1-28 U1-29 U1-30 U1-32 U1-33 U1-34 U1-35 U1-36 U1-37 Cumulative Operation Time Elapsed Time Software Number FLASH ID Terminal A1 Input Voltage Term A1 Level Total operating or power-on time of the Drive. Last 5 digits of the Drive's software number. 1hr - Input voltage on Terminal A1, as a percentage of ±10Vdc. 0.1% Terminal A2 Input Voltage Term A2 level Displays the input current (or voltage) on Terminal A2, as a percentage of ±10Vdc. 0.1% Terminal A3 Input Voltage Term A3 level Motor Secondary Current (Iq) Mot SEC Current Motor Excitation Current (Id) Mot EXC Current Output Frequency After Soft Start SFS Output ASR Input ASR Input ASR Output with Filter ASR Output w Fil PI Feedback Value PID Feedback Input voltage on Terminal A3, as a percentage of ±10Vdc. 0.1% Current being used by the motor to produce torque (Iq). 0.1% Current being used by the motor for excitation (Id). 0.1% DI-16H2 Input Status DI-16 Reference Output voltage reference (Vq) Voltage Ref (Vq) Output voltage reference (Vd) Voltage Ref (Vd) CPU Number CPU ID kWh kWh Lo 4 Digits MWh kWh Hi 5 Digits ACR output of q axis ACR(q) Output ACR output of d axis ACR(d) Output First Parameter Causing an OPE OPE Detected Zero Servo Pulse Count Zero Servo Pulse PID Input PID Input PID Output PID Output Frequency reference (speed command) after the accel and decel ramps and S-curve. Input error to the speed control loop (ASR). The maximum output frequency E1-04 corresponds to 100%. Output from the speed control loop (ASR). The motor rated secondary current corresponds to 100%. Feedback signal level when PID control is used. Reference value from a DI-16H2 Digital Reference Card. The value will be displayed in binary or BCD depending on user constant F3-01. 0.01Hz 0.01% 0.01% 0.01% Set by F3-01 Internal voltage reference for motor secondary current control. 0.1Vac Internal voltage reference for motor excitation current control. 0.1Vac Control board hardware revision. - Accumulated kilowatt-hours. 0.1kWh Accumulated megawatt-hours. 1MWh Current control output value for the motor secondary current. 0.1% Current control output value for the motor excitation current. 0.1% Parameter number causing an "OPE" fault. Number of PG pulses times 4 for the movement range when stopped at zero servo. Input error to the PID regulator (PID Setpoint - PID Feedback). Output of the PID regulator as a percentage of maximum frequency (E1-04). Parameters A - 39 1 pulse 0.01% 0.01% Table A.2 F7 Monitor List (Continued) Parameter No. U1-38 Parameter Name Digital Operator Display PID Setpoint PID Setpoint Description Setpoint of the PID regulator (PID reference + PID bias). Display Units 0.01% Modbus serial communication error codes. 0 0 0 0 0 0 0 0 1: CRC error 1: Data length error 0: Not used. Always 0. U1-39 Modbus Communication Error Code Transmit Err 1: Parity error - 1: Overrun error 1: Framing error 1: Timeout 0: Not used. Always 0. U1-40 Heatsink Cooling Fan Operation Time FAN Elapsed Time U1-44 ASR output without filter ASR out w/o Fil U1-45 Feed forward control output FF Cont Output Total operating time of the heatsink cooling fan. Output from the speed control loop (ASR) before the ASR primary delay filter (C5-06). 100% is displayed for rated secondary current of the motor. Output from feed forward control. 100% is displayed for rated secondary current of the motor. Parameters A - 40 1hr 0.01% 0.01% F7 Fault Trace List F7 Fault History List Table A.3 F7 Fault Trace List Table A.4 F7 Fault History List Fault Trace Fault History Current Fault. U2-01 Current Fault Previous Fault. U2-02 Last Fault Frequency Reference at Previous Fault. U2-03 Frequency Ref Output Frequency at Previous Fault. U2-04 Output Freq Output Current at Previous Fault. U2-05 Output Current Motor Speed at Previous Fault. U2-06 Motor Speed Output Voltage at Previous Fault. U2-07 Output Voltage DC Bus Voltage at Previous Fault. U2-08 DC Bus Voltage Output Power at Previous Fault. U2-09 Output kWatts Torque Reference at Previous Fault. U2-10 Torque Reference Input Terminal Status at Previous Fault. U2-11 The format is the same as for U1-10. Input Term Sts Output Terminal Status at Previous Fault. U2-12 The format is the same as for U1-11. Output Term Sts Drive Operation Status at Previous Fault. U2-13 The format is the same as for U1-12. Inverter Status Cumulative Operation Time at Previous Fault. U2-14 Elapsed time Note: Fault trace is not executed at CPF00, CPF01, CPF03, UV1, and UV2. U3-01 Most Recent Fault Last Fault U3-02 2nd Most Recent Fault Fault Message 2 U3-03 3rd Most Recent Fault Fault Message 3 U3-04 U3-05 4th Most Recent Fault Fault Message 4 Cumulative Operation Time at Most Recent Fault Elapsed Time 1 U3-06 Cumulative Operation Time at 2nd Most Recent Fault Elapsed Time 2 U3-07 Cumulative Operation Time at 3rd Most Recent Fault Elapsed Time 3 U3-08 Cumulative Operation Time at 4th Most Recent Fault Elapsed Time 4 U3-09 5th Most Recent Fault Fault Message 5 U3-10 6th Most Recent Fault Fault Message 6 U3-11 7th Most Recent Fault Fault Message 7 U3-12 8th Most Recent Fault Fault Message 8 U3-13 9th Most Recent Fault Fault Message 9 U3-14 10th Most Recent Fault Fault Message 10 U3-15 Cumulative Operation Time at 5th Most Recent Fault Elapsed Time 5 U3-16 Cumulative Operation Time at 6th Most Recent Fault Elapsed Time 6 U3-17 Cumulative Operation Time at 7th Most Recent Fault Elapsed Time 7 U3-18 Cumulative Operation Time at 8th Most Recent Fault Elapsed Time 8 U3-19 Cumulative Operation Time at 9th Most Recent Fault Elapsed Time 9 Cumulative Operation Time at 10th Most Recent Fault Elapsed Time 10 Note: Faults such as CPF00, CPF01, CPF02, CPF03, UV1, and UV2 are not stored in fault history. U3-20 Parameters A - 41 Notes: Parameters A - 42 Appendix B Capacity Related Parameters This appendix lists the parameters affected by the Drive Capacity setting of o2-04. Drive Capacity Selection..................................................... B-2 Parameters Affected by Drive Capacity Setting.................. B-3 Capacity Related Parameters B - 1 Drive Capacity Selection Parameter o2-04 sets the Drive capacity according to the model number. Parameter o2-04 needs to be adjusted only when replacing a control board. Do not change the o2-04 setting for any other reason. If the Drive’s control board is replaced, the next time the Drive is powered up, parameter o2-04 must be set to the appropriate value listed in Table B.1 for the Drive model number. This will automatically program the values of all other parameters listed in Table B.2 to the factory settings for that particular Drive rating. Table B.1 Drive Capacity Selection Voltage 208-240Vac 208-230Vac 480Vac F7 Model Number o2-04 Setting CIMR-F7U20P4 CIMR-F7U20P7 CIMR-F7U21P5 CIMR-F7U22P2 CIMR-F7U23P7 CIMR-F7U25P5 CIMR-F7U27P5 CIMR-F7U2011 CIMR-F7U2015 CIMR-F7U2018 CIMR-F7U2022 CIMR-F7U2030 CIMR-F7U2037 CIMR-F7U2045 CIMR-F7U2055 CIMR-F7U2075 CIMR-F7U2090 CIMR-F7U2110 CIMR-F7U40P4 CIMR-F7U40P7 CIMR-F7U41P5 CIMR-F7U42P2 CIMR-F7U43P7 CIMR-F7U44P0 CIMR-F7U45P5 CIMR-F7U47P5 CIMR-F7U4011 CIMR-F7U4015 CIMR-F7U4018 CIMR-F7U4022 CIMR-F7U4030 CIMR-F7U4037 CIMR-F7U4045 CIMR-F7U4055 CIMR-F7U4075 CIMR-F7U4090 CIMR-F7U4110 CIMR-F7U4132 CIMR-F7U4160 CIMR-F7U4185 CIMR-F7U4220 CIMR-F7U4300 0 1 2 3 4 5 6 7 8 9 A B C D E F 10 11 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 Capacity Related Parameters B - 2 Parameters Affected by Drive Capacity Setting The factory setting of the parameters in Table B.2 may change when the Drive capacity is changed via parameter o2-04. See Table B.3 and B.4 for a complete list. Table B.2 Parameters Affected by o2-04 Parameter Number Parameter Name Digital Operator Display Parameter Number Parameter Name Digital Operator Display b8-03 Energy Saving Control Filter Time Constant Energy Saving F.T E4-02 Motor 2 Rated Slip Motor Rated Slip b8-04 Energy Saving Coefficient Value Energy Save COEF E4-03 Motor 2 No-Load Current No-Load Current C6-01 Carrier Frequency Duty Heavy/Normal Duty E4-05 Motor 2 Line-to-Line Resistance Term Resistance E2-01 Motor Rated Current Motor Rated FLA E4-06 Motor 2 Leakage Inductance Leakage Inductance E2-02 Motor Rated Slip Motor Rated Slip E4-07 Motor 2 Rated Output Motor 2 Rated KW E2-03 Motor No-load Current No-load Current L2-02 Momentary Power Loss Ride-thru Time PwrL Ridethru t E2-05 Motor Line-to-Line Resistance Term Resistance L2-03 Momentary Power Loss Minimum Base Block Time PwrL Baseblock t E2-06 Motor Leakage Inductance Leakage Inductance L2-04 Momentary Power Loss Voltage Recovery Ramp Time PwrL V/F Ramp t E2-10 Motor Iron Loss for Torque Compensation Tcomp Iron Loss L8-02 Overheat Pre-Alarm Level OH Pre-Alarm Lvl E2-11 Motor Rated Output Motor Rated KW o2-04 Drive/kVA Selection Inverter Model # E4-01 Motor 2 Rated Current Motor Rated FLA - - Capacity Related Parameters B - 3 Parameter b8-03 b8-04 C6-01 C6-03 E2-01 / E4-01 E2-02 / E4-02 E2-03 / E4-03 E2-05 / E4-05 E2-06 / E4-06 E2-10 E2-11 / E4-07 L2-02 L2-03 L2-04 L8-02 o2-04 20P4 0.50 288.20 0 2, *10 1.90 2.90 1.20 9.842 18.2 14 0.4 0.1 0.1 0.3 95 0 20P7 0.50 223.70 0 2, *10 3.30 2.50 1.80 5.156 13.8 26 0.75 0.2 0.2 0.3 95 1 Table B.3 Parameter Defaults 208-240V 208-240V: Model Number CIMR-F7U21P5 22P2 23P7 25P5 0.50 0.50 0.50 0.50 169.40 156.80 122.90 94.75 0 0 0 0 2, *10 2, *8 2, *10 2, *15 6.20 8.50 14.00 19.60 2.60 2.90 2.73 1.50 2.80 3.00 4.50 5.10 1.997 1.601 0.771 0.399 18.5 18.4 19.6 18.2 53 77 112 172 1.5 2.2 3.7 5.5 0.3 0.5 1.0 1.0 0.3 0.4 0.5 0.6 0.3 0.3 0.3 0.3 95 100 95 95 2 3 4 5 27P5 0.50 72.69 0 2, *15 26.60 1.30 8.00 0.288 15.5 262 7.5 1.0 0.7 0.3 95 6 2011 0.50 70.44 0 2, *8 39.7 1.70 11.2 0.230 19.5 245 11 2.0 0.8 0.3 95 7 2015 0.50 63.13 0 2, *10 53.0 1.60 15.2 0.138 17.2 272 15 2.0 0.9 0.6 90 8 2075 2.00 23.10 0 2, *2 260.0 1.39 72.0 0.023 20.0 1200 75 2.0 1.3 1.0 110 F 2090 2.00 20.65 0 2, *2 260.0 1.39 72.0 0.023 20.0 1200 90 2.0 1.5 1.0 100 10 2110 2.00 18.12 1 2, *2 260.0 1.39 72.0 0.023 20.0 1200 110 2.0 1.7 1.0 95 11 * Default and maximum carrier frequency value when C6-01=2 (Normal Duty 2) Parameter b8-03 b8-04 C6-01 C6-03 E2-01 / E4-01 E2-02 / E4-02 E2-03 / E4-03 E2-05 / E4-05 E2-06 / E4-06 E2-10 E2-11 / E4-07 L2-02 L2-03 L2-04 L8-02 o2-04 2018 0.50 57.87 0 2, *10 65.8 1.67 15.7 0.101 20.1 505 18.5 2.0 1.0 0.6 100 9 Table B.3 Parameter Defaults 208-240V (continued) 208-240V: Model Number CIMR-F7U2022 2030 2037 2045 2055 0.50 0.50 0.50 0.50 2.00 51.79 46.27 38.16 35.78 31.35 0 0 0 0 0 2, *10 2, *10 2, *5 2, *5 2, *8 77.2 105.0 131.0 160.0 190.0 1.70 1.80 1.33 1.60 1.43 18.5 21.9 38.2 44.0 45.6 0.079 0.064 0.039 0.030 0.022 19.5 20.8 18.8 20.2 20.5 538 699 823 852 960 22 30 37 45 55 2.0 2.0 2.0 2.0 2.0 1.0 1.1 1.1 1.2 1.2 0.6 0.6 0.6 0.6 1.0 90 90 95 100 105 A B C D E * Default and maximum carrier frequency value when C6-01=2 (Normal Duty 2) Capacity Related Parameters B - 4 Parameter b8-03 b8-04 C6-01 C6-03 E2-01 / E4-01 E2-02 / E4-02 E2-03 / E4-03 E2-05 / E4-05 E2-06 / E4-06 E2-10 E2-11 / E4-07 L2-02 L2-03 L2-04 L8-02 o2-04 40P4 0.50 576.40 0 2, *2 1.00 2.90 0.60 38.198 18.2 14 0.4 0.1 0.1 0.3 95 20 40P7 0.50 447.40 0 2, *2 1.60 2.60 0.80 22.459 14.3 26 0.75 0.1 0.2 0.3 95 21 Table B.4 Parameter Defaults 480V Model Number CIMR-F7U41P5 42P2 43P7 44P0 0.50 0.50 0.50 0.50 338.80 313.60 245.80 236.44 0 0 0 0 2, *15 2, *15 2, *15 2, *15 3.10 4.20 7.00 7.00 2.50 3.00 2.70 2.70 1.40 1.50 2.30 2.30 10.100 6.495 3.333 3.333 18.3 18.7 19.3 19.3 53 77 130 130 1.5 2.2 3.7 4.0 0.2 0.3 0.5 0.5 0.3 0.4 0.5 0.6 0.3 0.3 0.3 0.3 95 95 95 95 22 23 24 25 45P5 0.50 189.50 0 2, *15 9.80 1.50 2.60 1.595 18.2 193 5.5 0.8 0.6 0.3 95 26 47P5 0.50 145.38 0 2, *15 13.30 1.30 4.00 1.152 15.5 263 7.5 0.8 0.7 0.3 95 27 4011 0.50 140.88 0 2, *8 19.9 1.70 5.6 0.922 19.6 385 11 1.0 0.8 0.3 95 28 4055 2.00 67.20 0 2, *5 95.0 1.46 24.0 0.088 20.0 1260 55 2.0 1.2 1.0 90 2F 4075 2.00 46.20 0 2, *5 130.0 1.39 36.0 0.092 20.0 1600 75 2.0 1.3 1.0 98 30 4090 2.00 38.91 0 2, *8 156.0 1.40 40.0 0.056 20.0 1760 90 2.0 1.5 1.0 108 31 * Default and maximum carrier frequency value when C6-01=2 (Normal Duty 2) Parameter b8-03 b8-04 C6-01 C6-03 E2-01 / E4-01 E2-02 / E4-02 E2-03 / E4-03 E2-05 / E4-05 E2-06 / E4-06 E2-10 E2-11 / E4-07 L2-02 L2-03 L2-04 L8-02 o2-04 4015 0.50 126.26 0 2, *10 26.5 1.60 7.6 0.550 17.2 440 15 2.0 0.9 0.3 95 29 4018 0.50 115.74 0 2, *10 32.9 1.67 7.8 0.403 20.1 508 18.5 2.0 1.0 0.6 98 2A Table B.4 Parameter Defaults 480V (continued) Model Number CIMR-F7U4022 4030 4037 4045 0.50 0.50 0.50 0.50 103.58 92.54 76.32 71.56 0 0 0 0 2, *10 2, *8 2, *8 2, *8 38.6 52.3 65.6 79.7 1.70 1.80 1.33 1.60 9.2 10.9 19.1 22.0 0.316 0.269 0.155 0.122 23.5 20.7 18.8 19.9 586 750 925 1125 22 30 37 45 2.0 2.0 2.0 2.0 1.0 1.1 1.1 1.2 0.6 0.6 0.6 0.6 78 85 85 90 2B 2C 2D 2E * Default and maximum carrier frequency value when C6-01=2 (Normal Duty 2) Capacity Related Parameters B - 5 Parameter b8-03 b8-04 C6-01 C6-03 E2-01 / E4-01 E2-02 / E4-02 E2-03 / E4-03 E2-05 / E4-05 E2-06 / E4-06 E2-10 E2-11 / E4-07 L2-02 L2-03 L2-04 L8-02 o2-04 4110 2.00 36.23 0 2, *5 190.0 1.40 49.0 0.046 20.0 2150 110 2.0 1.7 1.0 100 32 Table B.4 Parameter Defaults 480V (continued) Model Number CIMR-F7U4132 4160 4185 2.00 2.00 2.00 32.79 30.13 30.57 0 0 0 2, *5 2, *5 2, *2 223.0 270.0 310.0 1.38 1.35 1.30 58.0 70.0 81.0 0.035 0.029 0.025 20.0 20.0 20.0 2350 2850 3200 132 160 185 2.0 2.0 2.0 1.7 1.8 1.9 1.0 1.0 1.0 110 108 95 33 34 35 * Default and maximum carrier frequency value when C6-01=2 (Normal Duty 2) Capacity Related Parameters B - 6 4220 2.00 27.13 1 2, *2 370.0 1.30 96.0 0.020 20.0 3700 220 2.0 2.0 1.0 100 36 4300 2.00 21.76 1 2, *2 500.0 1.25 130.0 0.014 20.0 4700 300 2.1 2.1 1.0 95 37 Appendix C Specifications This appendix details the standard Drive specifications. Standard Drive Specifications ............................................C-2 Specifications C - 1 Standard Drive Specifications The standard Drive specifications are listed in the following tables. 208-240Vac Table C.1 208-240Vac Drive Specifications 208-240Vac Drives Output ratings Normal Duty*1 Power supply characteristics Control characteristics DC Measures Reactor for power supply harmonics 12-Pulse Rectification 208-230Vac Drives 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110*5 12.0 17.0 44.0 55.0 69.0 82.0 110.0 130.0 140.0 7.5 10 15 20 25 40 50 60 75 100 23.0 31.0 45.0 58.0 71 215 283.0 21P5 22P2 23P7 25P5 27P5 2.7 3.7 5.7 8.8 2 3 5 7.0 9.6 15.2 Heavy Duty*1 Model Number CIMR20P4 20P7 F7U Rated output 1.2 1.6 capacity (kVA) 0.5/0.75 1 Horsepower*2 Rated output 3.2 4.2 current (A) Overload capacity*3 (% of rated output current for 60 sec) Current limit (% of rated output current) Carrier frequency*5,*7 Maximum output frequency Rated output 1.4 1.8 capacity (kVA) 0.5/0.75 1 Horsepower*2 Rated output 3.6 4.6 current (A) Overload capacity*3 107 107 (% of rated output current for 60 sec.) Current limit (% of rated output current) Carrier frequency 10 10 (kHz)*6 Maximum output frequency Maximum output voltage Rated voltage Rated frequency Rated input current 3.8 4.9 Heavy Duty*1 (A) Rated input current 4.3 5.5 Normal Duty*1 (A) Allowable voltage fluctuation Allowable frequency fluctuation 22.0 27.0 32.0 30 85.0 115.0 145.0 180.0 125 150 346.0 360.0 150 138*3 150 138*3 2kHz 300.0Hz 3.0 4.1 6.4 8.8 12.0 18.0 2 3 5 7.5 10 15 7.8 10.8 16.8 23.0 31.0 46.2 108 107 107 120 120 117 23.0 29.0 34.0 44.0 62.0 73.0 82.0 120.0 40 50/60 75 - 100/125 59.4 74.8 88.0 115.0 162.0 192.0 215 312.0 117 20 25 114 30 140.0 160.0 150 - 360.0 415.0 116 120 107 113 120 109 115 120 10 10 5 5 8 2 2 2 120 10 8 10 15 15 8 10 10 400.0Hz 3-phase; 200, 208, 220, 230, or 240Vac (Proportional to input voltage) 3-phase, 200/208/220/230/240Vac, 50/60Hz 3-phase, 200/208/220/230Vac, 50/60Hz 8.4 11.5 18 24 37 52 68 84 94 120 160 198 237 317 381 396 9.4 13 20 24 37 53 70 89 98 120 180 212 237 350 396 457 + 10%, - 15% ±5% Optional Built-in Not possible Possible*4 *1 The difference between Heavy Duty ratings and the Normal Duty ratings for the Drive are the rated input and output current, overload capacity, carrier frequency, current limit, and maximum output frequency. Parameter C6-01 must be set to value of “0” for Heavy Duty ratings and “2” for Normal Duty ratings. Factory default is Heavy Duty (C6-01=0). *2 Horsepower ratings are based on 230V or 460V NEC Table 430.150. The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor and Drive, be sure that the Drive's rated output current is appropriate for the motor's rated current. *3 Model 2110 has an overload rating of 138% of rated output current for 60 seconds and a current limit rating of 138%. Models 4220 and 4300 have an overload rating of 150% of rated output current for 45 seconds and a current limit rating of 150%. *4 When setting the carrier frequency above the factory default, the Drive must be derated. *5 Heavy Duty ratings for models 2110, 4220 and 4300 are effective in software version VSF103021 and higher. *6 Each value shown is the Maximum carrier frequency and default carrier frequency. *7 The carrier frequency for Heavy Duty is default to 2 kHz. Software version VSF103021 and higher may allow the carrier frequency to be increased above 2 kHz with a reduction in continuous rated output current. Refer to C6-02 in Chapter 5 for further details. Specifications C - 2 480Vac Table C.2 480Vac Drive Specifications 41P5 42P2 43P7 44P0 45P5 Model Number CIMR-F7U 40P4 40P7 Rated output capacity (kVA) 1.4 1.6 Horsepower*2 0.5/0.75 1 2 3 5 - 7.5 10 15 20 25 30 1.8 2.1 3.7 5.3 7.6 8.7 12.5 17.0 24.0 31.0 39.0 45.0 13.0 21.0 26.0 30.0 38.0 Heavy Duty*1 Rated output current (A) 2.8 4.0 5.8 6.6 Overload capacity*3 (% of rated output current for 60 sec) Current limit (% of rated output current) Output ratings 4022 13.0 18.0 24.0 30.0 34.0 300.0Hz 1.4 Horsepower*2 Normal Duty 4018 2kHz Carrier Maximum output frequency Rated output capacity (kVA) *1 4015 150 1.6 2.8 4.0 5.8 6.6 9.5 0.5/0.75 1 2 3 5 - 7.5 10 15/20 25 30 - Rated output current (A) 1.8 2.1 3.7 5.3 7.6 8.7 12.5 17.0 27.0 34.0 40.0 50.4 Overload capacity *3 (% of rated output current for 60 sec) 120 120 120 120 120 120 120 120 107 109 117 107 15 15 8 10 10 10 Current limit (% of rated output current) *5 Power supply characteristics 4011 150 frequency*4 Control characteristics 9.5 47P5 Carrier frequency (kHz) Maximum output frequency Maximum output voltage Rated voltage Rated frequency Rated input current Heavy Duty*1 (A) Rated input current Normal Duty*1 (A) Allowable voltage fluctuation Allowable frequency fluctuation Measures for power supply harmonics 120 15 15 15 15 15 15 400.0Hz 3-phase; 380, 400, 415, 440, 460, or 480Vac (Proportional to input voltage.) 3-phase, 380, 400, 415, 440, 460 or 480Vac, 50/60Hz 2.2 2.5 4.4 6.4 9.0 10.4 15 20 29 37 47 50 2.2 2.5 4.4 6.4 9.0 10.4 15 20 33 40 48 55 + 10%, - 15% ±5% DC Reactor Optional 12-pulse Rectification Not possible *1 The difference between Heavy Duty ratings and the Normal Duty ratings for the Drive are the rated input and output current, overload capacity, carrier frequency, current limit, and maximum output frequency. Parameter C6-01 must be set to value of “0” for Heavy Duty ratings and “2” for Normal Duty ratings. Factory default is Heavy Duty (C6-01=0). *2 Horsepower ratings are based on 230V or 460V NEC Table 430.150. The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor and Drive, be sure that the Drive's rated output current is appropriate for the motor's rated current. *3 Model 2110 has an overload rating of 138% of rated output current for 60 seconds and a current limit rating of 138%. Models 4220 and 4300 have an overload rating of 150% of rated output current for 45 seconds and a current limit rating of 150%. *4 When setting the carrier frequency above the factory default, the Drive must be derated. *5 Heavy Duty ratings for models 2110, 4220 and 4300 are effective in software version VSF103021 and higher. *6 Each value shown is the Maximum carrier frequency and default carrier frequency. *7 The carrier frequency for Heavy Duty is default to 2 kHz. Software version VSF103021 and higher may allow the carrier frequency to be increased above 2 kHz with a reduction in continuous rated output current. Refer to C6-02 in Chapter 5 for further details. Specifications C - 3 Common Specifications Model Number CIMR-F7U Rated output capacity (kVA) *2 Heavy Duty*1 Horsepower Rated output current (A) 4030 Table C.2 480Vac Drive Specifications (Continued) 4037 4045 4055 4075 4090 4110 4132 Output ratings Normal 4300 57.0 69.0 85.0 110.0 140.0 160.0 200.0 230.0 280.0 315.0 450.0 40 60.0 50 75.0 60 91.0 75 112.0 100 150.0 125/150 180.0 216.0 200 260.0 250 304.0 300 370.0 350 414.0 500 590.0 150 150*3 150*3 Current limit (% of rated output current) 150 150*3 150*3 390.0 510.0 Carrier frequency*5 Maximum output frequency Duty*1 4220 46.0 2kHz 300.0Hz Rated output capacity (kVA) 51.0 59.0 73.0 95.0 120.0 140.0 180.0 200.0 230.0 Horsepower*2 Rated output current (A) 40/50 67.2 60 77.0 75 96.0 100 125.0 125 156.0 150 180.0 200 240.0 260.0 250 304.0 Overload capacity *3 (% of rated output current for 60 sec.) 107 117 114 108 115 120 108 120 120 107 118 120 5 5 2 2 2 Current limit (% of rated output current) 315.0 300/350 400/450 414.0 515.0 500+ 675.0 120 8 8 8 5 5 8 5 400.0Hz 3-phase, 380, 400, 415, 440, 460 or 480Vac (Proportional to input voltage) Rated voltage Rated frequency Power supply characteristics 4185 Overload capacity *3 (% of rated output current for 60 sec) Carrier frequency (kHz)*6 Maximum output frequency Maximum output voltage 3-phase, 380, 400, 415, 440, 460, or 480Vac, 50/60Hz Rated input current Heavy Duty*1 (A) 66 83 100 120 165 198 238 286 334 407 457 649 Rated input current Normal Duty*1 (A) 74 85 106 134 172 198 264 286 334 456 567 743 Allowable voltage fluctuation + 10%, - 15% Allowable frequency fluctuation Control characteristics 4160 Measures for power supply harmonics ±5% DC Reactor Built-in 12-Pulse Rectification Possible*4 *1 The difference between Heavy Duty ratings and the Normal Duty ratings for the Drive are the rated input and output current, overload capacity, carrier frequency, current limit, and maximum output frequency. Parameter C6-01 must be set to value of “0” for Heavy Duty ratings and “2” for Normal Duty ratings. Factory default is Heavy Duty (C6-01=0). *2. Horsepower ratings are based on 230V or 460V NEC Table 430.150. The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor and Drive, be sure that the Drive's rated output current is appropriate for the motor's rated current. *3 Model 2110 has an overload rating of 138% of rated output current for 60 seconds and a current limit rating of 138%. Models 4220 and 4300 have an overload rating of 150% of rated output current for 45 seconds and a current limit rating of 150%. *4 When setting the carrier frequency above the factory default, the Drive must be derated. *5 Heavy Duty ratings for models 2110, 4220 and 4300 are effective in software version VSF103021 and higher. *6 Each value shown is the Maximum carrier frequency and default carrier frequency. *7 The carrier frequency for Heavy Duty is default to 2 kHz. Software version VSF103021 and higher may allow the carrier frequency to be increased above 2 kHz with a reduction in continuous rated output current. Refer to C6-02 in Chapter 5 for further details. Specifications C - 4 The following specifications apply to both 200Vac and 400Vac Class Drives. Table C.3 Common F7 Drive Specifications Model Number CIMR-F7U Control method Speed control range Speed control accuracy Speed response Control Characteristics Torque limit 100:1 (1000:1 with PG) ±0.2% (±0.02% with PG) (77°F ± 50°F) (25°C ± 10°C) 5Hz (30Hz with PG) Can be set by parameter, analog input, or serial communication: 4 quadrant control ±5% Torque response 20Hz (40Hz with PG) Frequency control range Frequency accuracy (temperature characteristics) Frequency setting resolution 0.01 to 400.00Hz Digital references: ± 0.01% (14°F to 104°F) (-10°C to +40°C) Analog references: ±0.1% (77°F ± 50°F) (25°C ±10°C) Digital references: 0.01Hz Analog references: 0.03 @60Hz (10 bit with sign) Output frequency resolution Acceleration/Deceleration time Internal braking torque Main control functions Motor protection Instantaneous overcurrent protection Main circuit protection Overload protection Protective Functions Sine wave PWM V/F control, V/F control with PG, Open Loop Vector control, Flux Vector Control Torque accuracy Analog setting signal 0.001Hz -10 to +10Vdc, 0 to +10Vdc, 4 to 20mA 0.0 to 6000.0 sec (4 selectable combinations of independent acceleration and deceleration settings) Approximately 20% Restarting from momentary power loss, bi-directional speed search, Overtorque/Undertorque detection, 17 preset speeds, acceleration/deceleration time changes, S-curve acceleration, 3-wire sequence, Auto-Tuning, cooling fan ON/ OFF control, torque compensation, speed control/torque control switch, jump frequencies, upper and lower limits for frequency references, DC braking for starting and stopping, high-slip braking, PID control (with sleep function), energy-saving control, Modbus communications (RS-485/422, 19.2 kbps maximum), fault reset, and copy function. UL recognized electronic thermal overload relay (I2T) Stops at approximately 200% of rated output current Fuse in DC bus circuit Normal Duty (C6-01 = 2) - Approximately 110% of rated output current for 60 seconds Heavy Duty (C6-01 = 0) - 150% of rated output current for 60 seconds Model 2110 - 138% of rated output for 60 seconds Models 4220/4300 - 150% of rated output for 45 seconds Overvoltage protection 208-240Vac: Stops when main-circuit DC voltage is above 410Vdc 480Vac: Stops when main-circuit DC voltage is above 820Vdc Undervoltage protection 208-240Vac: Stops when main-circuit DC voltage is below 190Vdc 480Vac: Stops when main-circuit DC voltage is below 380Vdc Momentary power loss ride-thru Two selectable methods: 1. Time base for up to 2 seconds. 2. Until control power is active. Heatsink over-temperature Stall prevention Ground fault protection DC bus charge Enclosure Type Ambient operating temperature Environment Specification Ambient operating humidity Storage temperature Mounting location Protection by thermistor Stall prevention during acceleration, deceleration, and running Protection by electronic circuit (50% of inverter rated current) Lit when the main circuit DC voltage is approximately 50Vdc or more Enclosed wall-mounted type (NEMA 1): CIMR-F7U20P4 thru 2018 and 40P4 thru 4018 Open chassis type (IP00): CIMR-F7U2022 thru 2110 and 4030 thru 4300 14°F to 104°F (-10°C to 40°C) NEMA 1 type 14°F to 113°F (–10°C to 45°C) Open chassis type 95% max. (with no condensation) -4°F to 140°F (- 20°C to + 60°C) short-term temperature during transportation Indoor (no corrosive gas, dust, etc.) Altitude 3300 feet (1000 m) (higher altitudes by derate) Vibration 10 to 20Hz, 32 ft/sec2 (9.8 m/s2) max.; 20 to 50Hz, 6.5 ft/sec2 (2 m/s2) max. Specifications C - 5 Notes: Specifications C - 6 Appendix D Communications This appendix details the specifications, connections, and programming of the Drive for Modbus communication. Using Modbus Communication...........................................D-2 Modbus Function Code Details ..........................................D-8 Modbus Data Tables ........................................................D-10 Modbus Self-Diagnosis.....................................................D-18 Communications D - 1 Using Modbus Communication Serial communication can be performed with Program Logic Controllers (PLCs) or similar master devices using the Modbus protocol. Modbus Communication Configuration Modbus communication is configured using 1 master (PLC) and a maximum of 31 slaves. Serial communication between master and slave is normally initiated by the master and responded to by the slaves. The master performs serial communication with one slave at a time. Consequently, the slave address of each slave must be initially set, so that the master can perform serial communication using that address. Slaves receiving commands from the master perform the specified functions, and send a response back to the master. Master Slaves F7 F7 F7 Fig D.1 Example of Connections between Master and Drive Communication Specifications The Modbus communication specifications are shown below: Table D.1 Modbus Communication Specifications Specifications Interface RS-422, RS-485 Communications Cycle Asynchronous (Start-stop synchronization) Baud rate: Select from 1200, 2400, 4800, 9600, and 19200 bps. Data length: 8 bits fixed Communications Parameters Parity: Select from even, odd, or none. Stop bits: 1 bit selected Communications Protocol Modbus RTU Number of Connectable Units 31 units maximum Item Communications D - 2 Communication Connection Terminal Modbus communication uses the following terminals: S+, S-, R+, and R-. The terminating resistor must be turned ON only if the Drive is at the very end of the serial communication chain. Set the terminating resistor by turning ON pin 1 of switch S1. S1 RS-422A or RS-485 O F F Switch 1 1 2 Terminating resistor DIP Switch S1 located on terminal board. Terminating resistor (1/2W, 110 Ohms) Fig D.2 Communication Connection Terminals and Terminating Resistor IMPORTANT 1. Separate the communication cables from the main circuit cables and control circuit wiring. 2. Use shielded cables for the communication cable, and use proper shield clamps. Shield at one end only. 3. When using RS-485 communication, connect S+ to R+, and S- to R-, on the control circuit terminal board. See Fig D.3 below. Fig D.3 RS-485 Communication Connection Procedure for Setting Up Communication Use the following procedure to perform communication with the PLC. 1. Turn OFF the input to the Drive power and connect the communication cable between the PLC (or other master device) and the Drive. 2. Turn ON the input power to the Drive. 3. Set the required communication parameters (H5-01 to H5-07) using the Digital Operator. 4. Turn OFF the input to the Drive power, and check that the Digital Operator display has completely extinguished. 5. Turn ON the input power to the Drive once again. 6. Perform communication with the master device. Communications D - 3 Related Parameters Table D.2 Serial Communication Related Parameters Control Method Parameter No. Parameter Name Digital Operator Display Description Setting Range Factory Setting 0 to 4 V/F V/F w/ PG Open Loop Vector Flux Vector 1 Q Q Q Q b1-01 Frequency Reference Selection Reference Source Selects the frequency reference input source. 0: Operator - Digital preset speed U1-01 or d1-01 to d1-17. 1: Terminals - Analog input terminal A1 (or terminal A2 based on parameter H3-13). 2: Serial Com - Modbus RS-422/485 terminals R+, R-, S+, and S-. 3: Option PCB - Option board connected to 2CN. 4: Pulse Input (Terminal RP) b1-02 Run Command Selection Run Source Selects the run command input source. 0: Operator - RUN and STOP keys on Digital Operator. 1: Terminals - Contact closure on terminals S1 or S2. 2: Serial Com - Modbus RS-422/485 terminals R+, R-, S+, and S-. 3: Option PCB - Option board connected to 2CN. 0 to 3 1 Q Q Q Q H5-01 Drive Node Address Serial Comm Adr Selects Drive station node number (address) for Modbus terminals R+, R-, S+, S-. The Drive’s power must be cycled for the setting to take effect. Set H5-01 to 0 to disable Drive responses to Modbus communications. 0 to 20 Hex 1F A A A A H5-02 Communication Speed Selection Serial Baud Rate Selects the baud rate for Modbus terminals R+, R-, S+ and S-. The Drive’s power must be cycled for the setting to take effect. 0: 1200 bps 1: 2400 bps 2: 4800 bps 3: 9600 bps 4: 19200 bps 0 to 4 3 A A A A H5-03 Communication Parity Selection Serial Com Sel Selects the communication parity for Modbus terminals R+, R-, S+ and S-. The Drive’s power must be cycled for the setting to take effect. 0: No Parity 1: Even Parity 2: Odd Parity 0 to 2 0 A A A A H5-04 Stopping Method After Communication Error Serial Fault Sel Selects the stopping method when a communication timeout fault (CE) is detected. 0: Ramp to Stop 1: Coast to Stop 2: Fast-Stop 3: Alarm Only 4: Run at d1-04 0 to 3 3 A A A A H5-05 Communication Fault Detection Selection Serial Flt Dtct Enables or disables the communications timeout fault (CE). 0: Disabled - A communication loss will not cause a communication fault. 1: Enabled - If communication is lost for more than 2 seconds, a CE fault will occur. 0 to 10 1 A A A A H5-06 Drive Transmit Wait Time Transmit WaitTIM Set the delay time from when the Drive receives data to when the Drive sends data. 5 to 65 5ms A A A A H5-07 RTS Control Selection RTS Control Sel Enables or disables “request to send” (RTS) control: 0: Disabled (RTS is always on) 1: Enabled (RTS turns on only when sending) 0 to 1 1 A A A A Modbus communication can perform the following operations regardless of the settings in b1-01 and b1-02: 1. Monitor the operation status of the Drive. 2. Set and read Drive parameters. 3. Reset faults. 4. Input multi-function digital input commands. 5. Control multi-function digital and analog outputs. IMPORTANT An OR operation is performed between the multi-function command input from the master device and the command input from multi-function digital input terminals S3 to S8. Communications D - 4 Message Format In Modbus communication, the master sends commands to the slave, and the slave responds. The message format is configured for both sending and receiving as shown below. The length of the data packet is controlled by the command (function) contents. Slave address Function code Data Error check Fig D.4 Message Format The space between messages must support the following: PLC to Drive Command message PLC to Drive Drive to PLC Response message Command message Time (Seconds) 24 bits long H5-06 setting 5ms min. 24 bits long Fig D.5 Message Spacing Slave Address Set the Drive address from 0 to 20 Hex. If 0 is selected, commands from the master will be broadcast (i.e., the Drive will not return a response message). Function Code The function code specifies command type. There are four function codes, as shown below. Function Code (Hexadecimal) 03H 06H 08H 10H Table D.3 Modbus Function Codes Command Message Function Min. Max. (Bytes) (Bytes) Reading/Holding Register Contents Write In Single Holding Register Loopback Test Write In Several Holding Registers 8 8 8 11 * Minimum bytes for a normal Response Message (error response message is always 5 bytes). Communications D - 5 8 8 8 41 Response Message Min.* (Bytes) Max. (Bytes) 7 8 8 8 21 8 8 8 Data Configure consecutive data by combining the storage register address (test code for a loopback address) and the data the register contains. The data length changes depending on the command details. Error Check Errors are detected during communication using CRC-16. Perform calculations using the following method: 1. The factory setting for CRC-16 communication is typically zero, but when using the Modbus system, set the factory setting to one (e.g., set all 16 bits to 1). 2. Calculate CRC-16 using MSB as slave address LSB, and LSB as the MSB of the final data. 3. Calculate CRC-16 for response messages from the slaves and compare them to the CRC-16 in the response messages. CRC-16 At the end of the message, the data for CRC error checking is sent in order to detect errors in signal transmission. In Modbus RTU, the error check is conducted in the form of a CRC-16 (Cyclical Redundancy Check). The CRC field checks the contents of the entire message. It is applied regardless of any parity check method used for the individual characters of the message. The CRC field is two bytes, containing 16-bit binary value. The CRC value is calculated by the transmitting device, which appends the CRC to the message. The receiving device recalculates a CRC during receipt of the message, and compares the calculated value to the actual value it received in the CRC field. If the two values are not equal, an error results. The CRC is started by first preloading a 16-bit register to all 1’s. Then, a process begins of applying successive 8-bit bytes of the message to the current contents of the register. Start and stop bits and the parity bit (if one is used) do not apply to the CRC. During generation of the CRC, each 8-bit character is exclusive OR’ed with the register contents. Then the result is shifted in the direction of the least significant bit (LSB), with a zero filled into the most significant bit (MSB) position. The LSB is extracted and examined. If the LSB is a 1, the register is then exclusive OR’ed with a preset, fixed balue (A001h). If the LSB is a 0, no exclusive OR takes place. This process is repeated until eight shifts have been performed. After the last (eighth) shift, the next 8-bit byte is exclusive OR’ed with the register’s current value, and the process repeats for eight more shifts as described above. The final contents of the register, after all the bytes of the message have been applied, is the CRC value. For applications using a host computer, detailed examples of a CRC generation using Quick Basic and in C are shown on the following pages. Communications D - 6 Typical CRC-16 Calculation Program in Quick Basic crcsum# = &HFFFF& crcshift# = &H0& crcconst# = &HA001& CLS PRINT ”*********************************************” PRINT PRINT “ CRC-16 Calculator “ PRINT PRINT ”*********************************************” PRINT “If entering data in hex, precede the data with ‘&H’” PRINT “ Example: 32decimal = 20hex = &H20” PRINT ”*********************************************” PRINT INPUT “Enter the number of bytes in the message: “, maxbyte FOR bytenum = 1 TO maxbyte STEP 1 PRINT “Enter byte “; bytenum; “:”: INPUT byte& byte& = byte& AND &HFF& crcsum# = (crcsum# XOR byte7) AND &HFFFF& FOR shift = 1 TO 8 STEP 1 crcshift# = (INT(crcsum# / 2)) AND &H7FFF& IF crcsum# AND &H1& THEN crcsum# = crcshift# XOR crcconst# ELSE crcsum# = crcshift# END IF NEXT shift NEXT bytenum lower& = crcsum# AND &HFF& upper& = (INT(crcsum# / 256)) AND &HFF& PRINT “Lower byte (1st) = “, HEX$(lower&) PRINT “Upper byte (2nd) = “, HEX$(upper&) Typical CRC-16 Calculation Program in C // *buf // bufLen // *crc pointer to character array that contains the characters used to calculate CRC number of characters to calculate CRC for pointer to the array that contains the calculated CRC void getMBCRC(cahr *buf, int bufLen, char *crc) { unsigned long crc_0 = 0xffff; unsigned long crc_1 = 0x0000; int i,j; for (i=0; i> 1) & 0x7fff; if (crc_0 & 0x0001) crc_0 = (crc_1 ^ 0xa001); else crc_0 = crc_1; } } crc[0] = (unsigned char)((crc_0/256) & 0x00ff); crc[1] = (unsigned char)((crc_0 & 0x00ff); return; } // Declare and initialize variables // Loop through characters of input array // XOR current character with 0x00ff // Loop through character bits // Shift result right one place and store // if pre-shifted value bit 0 is set // XOR the shifted value with 0xa001 // if pre-shifted value bit 0 is not set // set the pre-shifted value equal to the shifted value // // Hi byte Lo byte No Response Message The Drive disregards the command message and does not return the response message in the following cases: 1. In simultaneous broadcasting of data (slave address field is 0), all slaves execute but do not respond. 2. When a communication error (overrun, framing, parity, or CRC-16) is detected in the command message. 3. When the slave address in the command message does not coincide with the address set in the slave. 4. When the command message data length is not proper. Communications D - 7 Modbus Function Code Details Reading/Holding Register Contents (03H) Read the contents of the storage register only for specified quantities. The addresses must be consecutive, starting from a specified address. The data content of the storage register are separated into higher 8 bits and lower 8 bits. The following table shows message examples when reading status signals, error details, data link status, and frequency references from the slave 2 Drive. Command Message Slave Address Function Code Higher Start Address Lower Higher Quantity Lower Higher CRC-16 Lower 02H 03H 00H 20H 00H 04H 45H F0H Response Message (During Normal Operation) Slave Address 02H Function Code 03H Data quantity 08H Higher 00H 1st storage register Lower 65H Higher 00H Next storage register Lower 00H Higher 00H Next storage register Lower 00H Higher 01H Next storage register Lower F4H Higher AFH CRC-16 Lower 82H Response Message (During Error) Slave Address 02H Function Code 83H Error code 03H Higher F1H CRC-16 Lower 31H Fig D.6 Function Code 03H Message Example Write In Single Holding Register (06H) Command Message Response Message (During Normal Operation) Response Message (During Error) Slave address 01H Slave address 01H Slave address 01H Function code 06H Function code 06H 80H + Function code 86H 00H Error Code 21H Register Address Higher Lower 01H Setting Data Higher 00H CRC-16 00H Lower 03H Higher 98H Lower 0BH Register Address Higher Lower 01H Setting Data Higher 00H CRC-16 Lower 03H Higher 98H Lower 0BH CRC-16 Fig D.7 Function Code 06H Message Example Communications D - 8 Higher 82H Lower 78H Loopback Test (08H) The loopback test returns the command message directly as the response message without changing the contents to check the communications between the master and slave. Set user-defined test code and data values. The following table shows a message example when performing a loopback test with the slave 1 Drive. Command Message Response Message (During Normal Operation) Response Message (During Error) Slave address 01H Slave address 01H Slave address 01H Function code 08H Function code 08H Function code 88H Higher 00H Error Code 01H Lower 00H Higher A5H Lower 37H Higher DAH Lower 8DH Test Code Data CRC-16 Higher 00H Lower 00H Higher A5H Lower 37H Higher DAH Lower 8DH Test Code Data CRC-16 CRC-16 Higher 86H Lower 50H Fig D.8 Function Code 08H Message Example Write In Several Holding Registers (10H) Write the specified data to the registers from the specified addresses. The written data must be consecutive, starting from the specified address in the command message: Higher 8 bits, then lower 8 bits, in storage register address order. The following table shows an example of a message when a forward run command and a speed command of 60.0Hz has been set in slave 1 by the PLC. IMPORTANT Set the number of data specified using command messages as quantity of specified messages x 2. Handle response messages in the same way. Command Message Slave Address Function Code Higher Start Address Lower Higher Quantity Lower No. of data Higher Lead data Lower Higher Next data Lower Higher CRC-16 Lower 01H 10H 00H 01H 00H 02H 04H 00H 01H 02H 58H 63H 39H Response Message (During Normal Operation) Slave Address 01H Function Code 10H Higher 00H Start Address Lower 01H Higher 00H Quantity Lower 02H Higher 10H CRC-16 Lower 08H Response Message (During Error) Slave Address 01H Function Code 90H Error code 02H Higher CDH CRC-16 Lower C1H * No. of data = 2 x (quantity) Fig D.9 Function Code 10H Message Example Communications D - 9 Modbus Data Tables The data tables are shown below. The types of data are as follows: Reference data, monitor data, broadcast data, and parameter data. Reference Data The reference data table is shown below. Reference data can be read and written to. Register No. 0000H Table D.4 Reference Data Contents Reserved Input terminal status Bit 0 Run Forward command Run = 1 Stop = 0 Bit 1 Run Reverse command Run = 1 Stop = 0 Bit 2 External fault: Fault (EFO) = 1 Bit 3 Fault reset: Reset command = 1 Bit 4 ComNet Bit 5 ComCtrl 0001H Bit 6 Multi-function digital input command 3 (terminal S3) Bit 7 Multi-function digital input command 4 (terminal S4) Bit 8 Multi-function digital input command 5 (terminal S5) Bit 9 Multi-function digital input command 6 (terminal S6) Bit A Multi-function digital input command 7 (terminal S7) Bit B Multi-function digital input command 8 (terminal S8) Bits C to F Not used 0002H Frequency reference (Set units using parameter o1-03) 0003H to 0005H Not used 0006H PID Setpoint 0007H Analog output 1 (terminal FM) setting (-11V = 726 to 11V = 726) → 10V = 660 0008H Analog output 2 (terminal AM) setting (-11V = 726 to 11V = 726) → 10V = 660 Multi-function contact output settings Bit 0 Digital output 1 (terminal M1-M2): ON = 1 OFF = 0 Bit 1 Digital output 2 (terminal M3-M4): ON = 1 OFF = 0 Bit 2 Digital output 3 (terminal M5-M6): ON = 1 OFF = 0 0009H Bits 3 to 5 Not used Bit 6 Set Fault contact (terminal MA-MC) output using bit 7: ON = 1 OFF = 0 Bit 7 Fault contact (terminal MA-MC): ON = 1OFF = 0 Bits 8 to F Not used 000AH to 000EH Not used Reference selection settings Bit 0 Not used Bit 1 Input PID setpoint 1: Enabled 0: Disabled Bits 3 to B Not used 000FH C Broadcast data terminal S5 input: Enabled = 1 Disabled = 0 D Broadcast data terminal S6 input: Enabled = 1 Disabled = 0 E Broadcast data terminal S7 input: Enabled = 1 Disabled = 0 F Broadcast data terminal S8 input: Enabled = 1 Disabled = 0 000CH to 000FH Refer to Table D.6, broadcast data, when using bits 000CH through 000FH Note:Write 0 to all unused bits. Do not write data to reserved or “Not Used” registers and bits. Communications D - 10 Monitor Data The following table shows the monitor data. Monitor data can only be read. Table D.5 Monitor Data Contents Register No. 0010H 0011H 0012H 0013H 0014H Status signal Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bits 8 to D Bit E Bit F Fault details Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 to F oPE details Not used Fault content 1 Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 Bit 9 Bit A Bit B Bit C Bit D Bit E Bit F Run command At zero speed Reverse operation Fault reset signal Speed agree Drive ready Alarm Fault Not used ComRef ComCtrl OPE error Err error Program mode 1CN status Not used oPE error code (OPE01=1, OPE02=2, OPE03=3, OPE06=6, OPE10=10, OPE11=11) Fuse blown (FU) DC bus undervoltage (UV1) Control power supply undervoltage (UV2) Main circuit answerback (UV3) Not used Ground fault (GF) Overcurrent (OC) Overvoltage (OV) Heatsink overtemperature (OH) Drive overheat (OH1) Motor overload (OL1) Drive overload (OL2) Overtorque 1 (OL3) Overtorque 2 (OL4) Dynamic Braking Transistor (RR) Dynamic Braking Resistor (RH) Note: Write 0 to all unused bits. Do not write data to reserved or “Not Used” registers and bits. Communications D - 11 Table D.5 Monitor Data (Continued) Contents Register No. 0015H 0016H 0017H 0018H Fault content 2 Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 Bit 9 Bit A Bit B Bit C Bit D Bit E Bit F Fault content 3 Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bits 7 to F CPF content 1 Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bits 7 to F CPF content 2 Bit 0 Bit 1 Bit 2 Bit 3 Bits 4 to F External fault 3 (EF3) External fault 4 (EF4) External fault 5 (EF5) External fault 6 (EF6) External fault 7 (EF7) External fault 8 (EF8) Not used Overspeed (OS) Speed deviation (DEV) PG open (PGO) Input phase loss (PF) Output phase loss (LF) DCCT fault (CF) Operator disconnect (OPR) EEPROM write-in fault (ERR) Not used Modbus communication error (CE) Bus error (BUS) E-15, SI-F/G communications error (E-15) E-10, SI-F/G fail Control fault (CF) Zero servo fault (SVE) External fault (EF0) Not used Not used Not used CPF02 fault CPF03 fault CPF04 fault CPF05 fault CPF06 fault Not used CPF20 fault CPF21 fault CPF22 fault CPF23 fault Not used Note: Write 0 to all unused bits. Do not write data to reserved or “Not Used” registers and bits. Communications D - 12 Table D.5 Monitor Data (Continued) Contents Register No. 0019H 001AH 001BH 001CH 001DH 001FH 0020H Alarm content 1 Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 Bit 9 Bit A Bit B Bit C Bit D Bit E Bit F Alarm content 2 Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 Bit 9 Bits A to F Not used Not used Not used Not used Drive status Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bits 8 to F Undervoltage (UV) Overvoltage (OV) Heatsink overtemperature (OH) Drive overheat fault (OH1) Overtorque 1 detection (OL3) Overtorque 2 detection (OL4) 2-wire sequence input (EF) External Baseblock (BB) External fault 3 (EF3) External fault 4 (EF4) External fault 5 (EF5) External fault 6 (EF6) External fault 7 (EF7) External fault 8 (EF8) Cooling fan (FAN) Overspeed (OS) Speed deviation (DEV) PG open (PGO) Operator disconnected (OPR) Modbus communication (CE) Bus error (BUS) Waiting for transmission (CALL) Motor overload (OL1) Drive overload (OL2) SI-R/G alarm (E-15) External fault (EF0) Not used Operation: Operating = 1 Stopped = 0 Reverse operation: Reverse operation 0: Forward operation Drive start-up complete: Completed = 1 Not completed = 0 Fault: Fault = 1 Data setting error: Error = 1 Multi-function digital output 1 (terminal M1 - M2): ON = 1 OFF = 0 Multi-function digital output 2 (terminal M3 - M4): ON = 1 OFF = 0 Multi-function digital output 3 (terminal M5 - M6): ON = 1 OFF = 0 Not used Note: Communication error details are stored until an error reset is input (errors can be reset while the Drive is operating). Note: Write 0 to all unused bits. Do not write data to reserved or “Not Used” registers and bits. Communications D - 13 Table D.5 Monitor Data (Continued) Contents Register No. 0021H Fault details Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 Bit 9 Bit A Bit B Bit C 0022H 0023H 0024H 0025H 0026H 0027H 0028H 0029H 002AH 002BH Bit D Bit E Bit F Data link status Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bits 5 to F Frequency reference Output frequency Output voltage reference Output current Output power Torque reference Not used Not used Sequence input status Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bits 8 to F Overcurrent (OC) or Ground fault (GF) Main circuit overvoltage (OV) Drive overload (OL2) Drive overheat (OH1, OH2) Not used Fuse blown (PUF) PID feedback reference lost (FbL) External error (EF, EFO) Hardware error (CPF) Motor overload (OL1) or Overtorque 1 (OL3) detected PG open detected (PGO), Overspeed (OS) or Speed deviation (DEV) Main circuit undervoltage (UV) alarm Main circuit undervoltage (UV1), control power supply error (UV2), Soft charge circuit error (UV3) Output phase loss (LF) Modbus communication error (CE) Operator disconnected (OPR) Writing data Not used Not used Upper and lower limit errors Data integrity error Not used U1-01 U1-02 U1-06 U1-03 U1-08 U1-09 Input terminal S1: ON = 1 OFF = 0 Input terminal S2: ON = 1 OFF = 0 Multi-function digital input terminal S3: ON = 1 OFF = 0 Multi-function digital input terminal S4: ON = 1 OFF = 0 Multi-function digital input terminal S5: ON = 1 OFF = 0 Multi-function digital input terminal S6: ON = 1 OFF = 0 Multi-function digital input terminal S7: ON = 1 OFF = 0 Multi-function digital input terminal S8: ON = 1 OFF = 0 Not used Note: Write 0 to all unused bits. Do not write data to reserved or “Not Used” registers and bits. Communications D - 14 Register No. 002CH 002DH 002EH - 0030H 0031H 0032H - 0037H 0038H 0039H 003AH 003BH 003CH 003DH 003EH 003FH Table D.5 Monitor Data (Continued) Contents Drive status Bit 0 Operation: Operating = 1 Bit 1 Zero speed: Zero speed = 1 Bit 2 Frequency agree: Matched = 1 Bit 3 Desired frequency agree: Matched = 1 Bit 4 Frequency detection 1: Output frequency ≤ L4-01 = 1 Bit 5 Frequency detection 2: Output frequency ≥ L4-01 = 1 Bit 6 Drive start-up completed: Start-up completed = 1 Bit 7 Low voltage detection: Detected = 1 Bit 8 Baseblock: Drive output baseblock = 1 Bit 9 Frequency reference mode: Not communication = 1 Communication = 0 Bit A Run command mode: Not communication = 1 Communication = 0 Bit B Overtorque detection: Detected = 1 Bit C Frequency reference lost: Lost = 1 Bit D Retrying error: Retrying = 1 Bit E Error (including Modbus communications time-out): Error occurred = 1 Bit F Modbus communications time-out Timed out = 0 Multi-function digital output status Bit 0 Multi-function digital output 1 (terminal M1-M2): ON = 1 OFF = 0 Bit 1 Multi-function digital output 2 (terminal M3-M4): ON = 1 OFF = 0 Bit 2 Multi-function digital output 3 (terminal M5-M6): ON = 1 OFF = 0 Bits 3 to F Not used Not used Main circuit DC voltage Not used PID feedback level (Input equivalent to 100%/Max. output frequency; 10/1%; without sign) PID input level (±100%/±Max. output frequency; 10/1%; with sign) PID output level (±100%/±Max. output frequency; 10/1%; with sign) CPU software number Flash software number Communication error details Bit 0 CRC error Bit 1 Invalid data length Bit 2 Not used Bit 3 Parity error Bit 4 Overrun error Bit 5 Framing error Bit 6 Time-out Bits 7 to F Not used kVA setting Control method Note: Communication error details are stored until an error reset is input (errors can be reset while the Drive is operating). Note: Write 0 to all unused bits. Do not write data to reserved or “Not Used” registers and bits. Communications D - 15 Broadcast Data The following table shows the broadcast data. Table D.6 Broadcast Data Register Address 0001H 0002H Contents Operation signal Bit 0 Bit 1 Bits 2 and 3 Bit 4 Bit 5 Bits 6 to B Bit C Bit D Bit E Bit F Frequency reference Run command: Running = 1 Stopped = 0 Run direction: Reverse = 1 Forward = 0 Not used External fault (set using H1-01): Fault = 1 Fault reset (set using H1-02): Reset = 1 Not used Multi-function digital input terminal S5 input Multi-function digital input terminal S6 input Multi-function digital input terminal S7 input Multi-function digital input terminal S8 input 30000/100% Note: Bit signals not defined in the broadcast operation signals use local node data signals continuously. Note: Refer to register 000FH, bits 000CH through 000FH, in Table D.4 when using bits 000CH through 000FH of broadcast data register 0001H. Enter Command When writing parameters to the Drive from the master using Modbus communication, the parameters are temporarily stored in the constant data area in the Drive, and they will be lost if power to the Drive is shut OFF. To enable these parameters in the parameter data area, which is retained when power is removed, use the Enter command. There are two types of Enter commands: 1. Enter command that enables parameter data in RAM. 2. Enter command that writes data to EEPROM (non-volatile memory) in the Drive and also enables data in RAM. The following table shows the Enter command registers. Enter command registers can only be written. The Enter command is enabled by writing 0 to register number 0900H or 0910H. Register No. 0900H 0910H IMPORTANT Table D.7 Enter Command Contents Write parameter data to EEPROM. Parameter data is not written to EEPROM, but refreshed in RAM only. The maximum number of times you can write to EEPROM using the Drive is 100,000. Do not frequently execute Enter command (0900H) written to EEPROM. The Enter command registers are write-only. Consequently, if reading these registers, the register address will become invalid (Error code: 02H). Communications D - 16 Error Codes The following table shows Modbus communication error codes. Table D.8 Error Codes Error Code Contents 01H Function code error A function code other than 03H, 08H, or 10H has been set by the master. 02H Invalid register number error • The register address you are attempting to access is not recorded anywhere. • With broadcast sending, a start address other than 0000H, 0001H, or 0002H has been set. 03H Invalid quantity error • The number of data packets being read or written is outside the range of 1 to 16. • In write mode, the number of data packets in the message is not No. of packets x 2. 21H Data setting error • Upper limit or lower limit error has occurred in the control data or when writing parameters. • When writing parameters, the parameter setting is invalid. 22H Write mode error • Attempting to write parameters to the Drive during run. • Attempting to write via Enter commands during run. • Attempting to write parameters other than A1-00 to A1-05, E1-03, or 02-04 when a CPF03 (defective EEPROM) fault has occurred. • Attempting to write read-only data. 23H Writing during main circuit undervoltage (UV) fault • Writing parameters to the Drive during UV (main circuit undervoltage) alarm. • Writing via Enter commands during UV (main circuit undervoltage) alarm. 24H Writing error during parameters processing Attempting to write parameters while processing parameters in the Drive. Slave Not Responding In the following cases, the slave will ignore the write function. • When a communication error (overrun, framing, parity, or CRC-16) is detected in the command message. • When the slave address in the command message and the slave address in the Drive do not agree. • When the data that configures the message and the data time length exceed 24 bits. • When the command message data length is invalid. IMPORTANT If the slave address specified in the command message is 0, all slaves execute the write function, but do not return response messages to the master. Communications D - 17 Modbus Self-Diagnosis The Drive has a built-in function for self-diagnosing the operations of the serial communication interface circuits. The self-diagnosis function tests the serial communications hardware of the Drive by jumpers the send and receive terminals to receive the same message as the Drive sends. Perform the self-diagnosis function using the following procedure. 1. Turn ON the power supply to the Drive, and set parameter H1-05 (Terminal S7 function selection) to 67 (communication test mode). 2. Turn OFF the power supply to the Drive. 3. Jumper the following terminals while the power supply is turned OFF (see diagram below): Connect S+ to R+. Connect S- to R-. Connect S7 to SN. 4. Turn ON the terminating resistor. (Turn ON pin 1 on DIP switch 1). 5. Turn ON the power supply to the Drive again. SN E(G) SC S1 SP S2 A1 S3 A2 S4 +V S5 Fig D.10 AC S6 S7 -V A3 S8 MP AC RP FM AC AM IG R+ R- S+ M5 M6 MA MB MC S- M3 M4 M1 M2 E(G) Communication Terminal Connection for Self -Diagnosis Function 6. During normal self-diagnostic operation, the Digital Operator displays the frequency reference value. If an error occurs, a CE (Modbus communication error) alarm will be displayed on the Digital Operator, the fault contact output will be turned ON, and the Drive operation ready signal will be turned OFF. Communications D - 18 Appendix E Peripheral Devices This appendix describes recommended branch short circuit protection and peripheral devices. Branch Circuit Short Circuit Protection............................... E-2 Branch Circuit Overload Protection.................................... E-5 Peripheral Devices ............................................................. E-6 Peripheral Devices E - 1 Branch Circuit Short Circuit Protection The following peripheral devices may be required between the AC main circuit power supply and the Drive input terminals L1(R), L2(S), and L3(T). Refer to applicable codes to determine the devices necessary for a given installation. Use Table E.1 or E.2 when selecting fuses and circuit breakers per the NEC. When selecting semiconductor fuses to provide Drive input I2t protection and comply with UL, CSA, NEC, and CEC branch circuit short circuit protection requirements, select one of the fuses in Table E.3 or E.4. Fuse Type: UL designated Time-Delay or Non-Time-Delay Fuse Class: CC, J, T, RK1 or RK5 Designators (typical): KTK, FNQ, FRS, LPJ, LPS, JKS, JJN, or JJS Voltage Rating: 250V for Drives with 208-240V input 600V for Drives with 480V input Circuit Breaker Type: Inverse Time (MCCB) or Instantaneous Trip (MCP) Voltage Rating: 600V Table E.1 Recommended Fuse and Circuit Breaker Ratings per NEC (208-240Vac Input) Input Amps *1 (Continuous Rating) Output Amps *1 (Continuous Rating) Fuse Selection Criteria Circuit Breaker Selection Criteria Maximum Time-Delay Fuse Rating (A) Maximum Non-Time-Delay Fuse Rating (A) Maximum CB Rating (A) Model CIMR-F7U Hp 20P4 0.5/0.75 4.3 3.6 6 12 15 20P7 1 5.5 4.6 8 12 15 21P5 1.5/2 9.4 7.8 15 15 15 22P2 3 13 10.8 20 20 20 23P7 5 20 16.8 30 30 35 25P5 7.5 24 23 40 50 45 27P5 10 37 31 60 80 80 2011 15 53 46.2 80 80 100 2015 20 70 59.4 110 125 125 2018 25 89 74.8 125 150 150 2022 30 98 88 150 150 175 2030 40 120 115 200 200 225 2037 50 180 162 250 250 300 2045 60 212 192 300 300 350 2055 75 237 215 350 350 450 2075 75/100 350 312 450 450 600 2090 125 396 360 600 600 700 2110 150 457 415 700 700 900 *1 Input and Output Amps are based on the Normal Duty (ND) current rating. Consult the Specification section for details on the Heavy Duty (HD) and Normal Duty (ND) ratings. Peripheral Devices E - 2 Table E.2 Recommended Fuse and Circuit Breaker Ratings per NEC (480Vac Input) Model CIMR-F7U Hp 40P4 0.5/0.75 Input Amps *1 (Continuous Rating) Output Amps *1 (Continuous Rating) 2.2 1.8 Fuse Selection Criteria Circuit Breaker Selection Criteria Maximum Time-Delay Fuse Rating (A) Maximum Non-Time-Delay Fuse Rating (A) Maximum CB Rating (A) 4 10 15 40P7 1 2.5 2.1 4 10 15 41P5 1.5/2 4.4 3.7 8 12 15 42P2 3 6.4 5.3 10 15 15 43P7 5 9 7.6 15 20 20 44P0 - 10.4 8.7 15 30 20 45P5 7.5 15 12.5 25 30 30 47P5 10 20 17 30 30 40 4011 15/20 33 27 45 50 60 4015 25 40 34 60 70 80 4018 30 48 40 70 80 90 4022 - 55 50.4 80 80 100 4030 40/50 74 67.2 100 100 125 4037 60 85 77 125 125 150 4045 75 106 96 150 150 200 4055 100 134 125 200 200 225 4075 125 172 156 250 250 300 4090 150 198 180 300 300 400 4110 200 264 240 350 350 450 4132 - 286 260 400 400 600 4160 250 334 304 450 450 700 4185 300/350 456 414 600 600 800 4220 400/450 567 515 700 700 1000 4300 500+ 743 675 900 900 1200 *1 Input and Output Amps are based on the Normal Duty (ND) current rating. Consult the Specification section for details on the Heavy Duty (HD) and Normal Duty (ND) ratings. Peripheral Devices E - 3 Table E.3 Semiconductor Fuses for Drive I2t Protection and Branch Circuit Short Circuit Protection (200V Series) Recommended Alternate 1 Alternate 2 Drive Model No. CIMR-F7* Fuse Mfr. Model No. Rating Fuse Mfr. Model No. Rating 20P4 Ferraz A60Q12-2 600V, 12A Ferraz A070GRB006T13 700V, 6A Bussmann FWH-20A14F 500V, 20A 20P7 Ferraz A60Q12-2 600V, 12A Ferraz A070GRB006T13 700V, 6A Bussmann FWH-20A14F 500V, 20A 21P5 Ferraz A60Q15-2 600V, 15A Ferraz A70QS25-22F 700A, 25A Bussmann FWH-20A14F 500V, 20A 22P2 Ferraz A60Q20-2 600V, 20A Ferraz 6,900CPGRC14.51/25 690V, 25A Bussmann FWH-25A14F 500V, 25A 23P7 Ferraz A60Q30-2 600V, 30A Ferraz A70QS32-14F 700A, 32A Bussmann FWH-45B 500V, 45A 25P5 Ferraz A50P50-4 500V, 50A Ferraz A70QS50-14F 700V, 50A Bussmann FWH-80B 500V, 80A 27P5 Ferraz A50P80-4 500V, 80A Ferraz A50QS70-4 500V, 70A Bussmann FWH-80B 500V, 80A A50P80-4 Fuse Mfr. Model No. Rating 2011 Ferraz 500V, 80A Ferraz A50QS100-4 500V, 100A Bussmann FWH-100B 500V, 100A 2015 Ferraz A50P125-4 500V, 125A Ferraz A50QS150-4 500V, 150A Bussmann FWH-175B 500V, 175A 2018 Ferraz A50P150-4 500V, 150A Ferraz A50QS175-4 500V, 175A Bussmann FWH-200B 500V, 200A 2022 Ferraz A50P150-4 500V, 150A Ferraz A50QS200-4 500V, 200A Bussmann FWH-200B 500V, 200A 2030 Ferraz A50P200-4 500V, 200A Bussmann FWH-200B 500V, 200A Bussmann FWH-225B 500V, 225A 2037 Ferraz A50P250-4 500V, 250A Ferraz A30QS275-4 300V, 275A Bussmann 170M4610 690V, 315A 2045 Ferraz A50P300-4 500V, 300A Ferraz A30QS350-4 300V, 350A Bussmann FWH-350A 500V, 350A 2055 Ferraz A50P350-4 500V, 350A Bussmann FWH-400A 500V, 400A Bussmann FWH-450A 500V, 450A 2075 Ferraz A50P450-4 500V, 450A Ferraz A070URD33KI0550 700V, 550A Bussmann FWH-500A 500V, 500A 2090 Ferraz A50P600-4 500V, 600A Ferraz A70P600-4 700V, 600A Bussmann FWH-600A 500V, 600A 2110 Ferraz A50P600-4 500V, 600A Ferraz A70P700-4 700V, 700A Bussmann FWH-700A 500V, 700A * Denotes letter A through Z Peripheral Devices E - 4 Table E.4 Semiconductor Fuses for Drive I2t Protection and Branch Circuit Short Circuit Protection (400V Series) Recommended Alternate 1 Alternate 2 Drive Model No. CIMR-F7* Fuse Mfr. Model No. Rating Fuse Mfr. Model No. Rating Fuse Mfr. Model No. Rating 40P4 Ferraz A60Q10-2 600V, 10A Ferraz A070GRB006T13 700V, 6A Ferraz A70QS16-14F 690V, 16A 40P7 Ferraz A60Q10-2 600V, 10A Ferraz A070GRB006T13 700V, 6A Ferraz A70QS16-14F 690V, 16A 41P5 Ferraz A60Q12-2 600V, 12A Ferraz 6,900CPGRC14.51/25 690V, 25A Ferraz A70QS20-14F 690V, 20A 42P2 Ferraz A60Q15-2 600V, 15A Ferraz A70QS25-22F 700V, 25A Ferraz A70QS20-14F 690V, 20A 43P7 Ferraz A60Q20-2 600V, 20A Ferraz A70QS20-14F 700V, 20A Ferraz A70QS25-14F 690V, 25A 44P0 Ferraz A60Q30-2 600V, 30A Ferraz A70QS32-14F 700V, 32A Ferraz A70QS40-14F 690V, 40A 45P5 Ferraz A60Q30-2 600V, 30A Ferraz A70QS32-14F 700V, 32A Ferraz A70QS40-14F 690V, 40A 47P5 Ferraz A60Q30-2 600V, 30A Ferraz A70QS40-14F 700V, 40A - - - 4011 Ferraz A70P50-4 700V, 50A Ferraz A50QS50-4 500V, 50A Bussmann FWH-80B 500V, 80A 4015 Ferraz A70P70-4 700V, 70A Ferraz A50QS80-4 500V, 80A Bussmann FWH-100B 500V, 100A 4018 Ferraz A70P80-4 700V, 80A Ferraz A50QS100-4 500V, 100A Bussmann FWH-125B 500V, 125A 4022 Ferraz A70P80-4 700V, 80A Ferraz A50QS100-4 500V, 100A Bussmann FWH-125B 500V, 125A 4030 Ferraz A70P100-4 700V, 100A Ferraz A50QS125-4 500V, 125A Bussmann FWH-125B 500V, 125A 4037 Ferraz A70P125-4 700V, 125A Ferraz A50QS125-4 500V, 125A Bussmann FWH-150B 500V, 150A 4045 Ferraz A70P150-4 700V, 150A Ferraz A50QS150-4 500V, 150A Bussmann FWH-175B 500V, 175A 4055 Ferraz A70P200-4 700V, 200A Ferraz A70QS200-4 700V, 200A Bussmann FWH-200B 500V, 200A 4075 Ferraz A70P250-4 700V, 250A Ferraz A50QS250-4 500V, 250A Bussmann FWH-250A 500V, 250A 4090 Ferraz A70P300-4 700V, 300A Ferraz A50QS300-4 500V, 300A Bussmann 170M4611 690V, 350A 4110 Ferraz A70P350-4 700V, 350A Ferraz A50P350-4 500V, 350A Bussmann 170M4611 690V, 350A 4132 Ferraz A70P400-4 700V, 400A Ferraz A70P500-4 700V, 500A Bussmann 170M5610 690V, 500A 4160 Ferraz A70P450-4 700V, 450A Ferraz A70QS700-4 700V, 700A Bussmann FWH-600A 500V, 600A 4185 Ferraz A70P600-4 700V, 600A Ferraz A70QS700-4 700V, 700A Bussmann FWH-700A 500V, 700A 4220 Ferraz A70P700-4 700V, 700A Bussmann FWH-800A 500V, 800A Bussmann FWH-1000A 500V, 1000A 4300 Ferraz A70P900-4 700V, 900A Bussmann FWH-1000A 500V, 1000A Bussmann FWH-1200A 500V, 1200A * Denotes letter A through Z Branch Circuit Overload Protection All models have built-in UL evaluated motor overload protection. Motor overload protection is also provided in accordance with the NEC and CEC. Additional branch circuit overload protection is not required for single motor applications. Peripheral Devices E - 5 Peripheral Devices The following peripheral devices may be required to be mounted between the AC main circuit power supply and the Drive input terminals R/LI, S/L2, and T/L3. CAUTION Never connect a general LC/RC noise filter to the Drive output circuit. Never connect a phase-advancing capacitor to the input or output sides, or a surge suppressor to the output side of the Drive. When magnetic contactor is installed between the Drive and the motor, never turn it on or off during operation. For more details on peripheral devices, contact the manufacturer. Magnetic Contactor Mount a surge protector on the coil. When using a magnetic contactor to start and stop the Drive, do not exceed one start per hour. AC and DC reactor When using models F7U20P4 thru F7U2018 and F7U40P4 thru F7U4018 on a power supply transformer with a capacity of 600kVA or more, install an AC or DC reactor. The reactor improves the input power factor and provides protection to the rectifier circuit within the Drive. Noise Filter Use a noise filter exclusively for the Drive if radio noise generated from the Drive causes other control devices to malfunction. See Chapter 2. Peripheral Devices E - 6 Appendix F Spare Parts This appendix lists the primary spare parts that may be needed to maintain or service the Drive. F7 Primary Spare Parts - 208/230/240Vac......................... F-2 F7 Primary Spare Parts - 480Vac....................................... F-3 Spare Parts F - 1 F7 Primary Spare Parts - 208/230/240Vac Table F.1 208-240Vac F7 Primary Spare Parts Drive Model CIMR-F7U 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110 Hp Power PCB (3PCB) Gate Drive PCB (3PCB) Control PCB (1PCB) Terminal PCB (2PCB) Diode Module 0.5/0.75 1 1.5/2 3 5 7.5 10 15 20 25 30 40 50 60 75 75/100 125 150 ETP617012 ETP617012 ETP617022 ETP617032 ETP617042 ETP617052 ETP617062 ETP617422 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A ETC617032 ETC617042 ETC617053 ETC617063 ETC617073 ETC617083 ETC617093 ETC617103 ETC617113 ETC617531 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 Inside the Power Module Inside the Power Module Inside the Power Module Inside the Power Module Inside the Power Module Inside the Power Module Inside the Power Module SID003114 (D1) SID003113 (D1) SID003113 (D1) SID003114 (D1,D2) SID003113 (D1,D2) SID003130 (D1,D2) SID003115 (D1,D2) SID003115 (D1,D2) SID003116 (D1-D6) SID003116 (D1-D6) SID003108 (D1-D12) Table F.1 208-240Vac F7 Primary Spare Parts (Continued) Drive Model CIMR-F7U Hp Power Module Transistor Module DC Bus Fuse Heat Sink Fan Internal Fan 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110 0.5/0.75 1 1.5/2 3 5 7.5 10 15 20 25 30 40 50 60 75 75/100 125 150 STR001297 (Q1) STR001297 (Q1) STR001299 (Q1) STR001301 (Q1) STR001303 (Q1) STR001304 (Q1) STR001278 (Q1) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A STR001315 (Q1) STR001315 (Q1) STR001320 (Q1) STR001314 (Q1) STR001323 (Q1) STR001293 (Q1-Q3) STR001335 (Q1-Q3) STR001335 (Q1-Q3) STR001349 (Q1-Q6) STR001338 (Q1-Q6) STR001351 (Q1-Q12) FU-002029 (F1) FU-002029 (F1) FU-002029 (F1) FU-002030 (F1) FU-002031 (F1) FU-002099 (F1) FU-002107 (F1) FU-002108 (F1) FU-002108 (F1) FU-002109 (F1) FU-002110 (F1) FU-002110 (F1) FU-002102 (F1) FU-000925 (F1) FU-000938 (F1) FU-000926 (F1) FU-002105 (F1) FU-002106 (F1) N/A N/A N/A N/A FAN001066 (B1) FAN001066 (B1) FAN001066 (B1,B2) FAN001066 (B1,B2) FAN001065 (B1,B2) FAN001065 (B1,B2) FAN001039 (B1,B2) FAN001039 (B1,B2) FAN001049 (B1,B2) FAN001049 (B1,B2) FAN001052 (B1,B2) FAN001056 (B1,B2) FAN001056 (B1,B2) FAN001056 (B1,B2) N/A N/A N/A N/A N/A N/A N/A FAN001043 (B3) N/A FAN001043 (B3) N/A N/A FAN001053 (B4) FAN001053 (B4) FAN001054 (B4) FAN001054 (B4) FAN001054 (B4) FAN001054 (B4) Spare Parts F - 2 F7 Primary Spare Parts - 480Vac Table F.2 480Vac F7 Primary Spare Parts Drive Model CIMR-F7U 40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 Hp Power PCB (3PCB) Gate Drive PCB (3PCB) Control PCB (1PCB) Terminal PCB (2PCB) Diode Module 0.5/0.75 1 1.5/2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125/150 200 250 300 350/400 450/500+ ETP617082 ETP617082 ETP617092 ETP617102 ETP617112 ETP617122 ETP617132 ETP617142 ETP617152 ETP617162 ETP617172 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A ETC617141 ETC617151 ETC617161 ETC617171 ETC617181 ETC617190 ETC617200 ETC617210 ETC617220 ETC617230 ETC617240 ETC617250 ETC617260 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618390-S3020 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 ETC618410 Inside the Power Module Inside the Power Module Inside the Power Module Inside the Power Module Inside the Power Module Inside the Power Module Inside the Power Module Inside the Power Module Inside the Power Module SID003112 (D1) SID000605 (D1) SID003112 (D1,D2) SID003112 (D1,D2) SID003112 (D1,D2) SID000605 (D1,D2) SID000605 (D1,D2) SID003117 (D1,D2) SID003117 (D1,D2) SID003109 (D1-D6) SID003118 (D1-D6) SID003119 (D1-D6) SID003119 (D1-D6) SID003131 (D1-D6) SID003119(D1-D12) Table F.2 480Vac F7 Primary Spare Parts (Continued) Drive Model CIMR-F7U Hp Power Module Transistor Module DC Bus Fuse Heat Sink Fan Internal Fan 40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 0.5/0.75 1 1.5/2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125/150 200 250 300 350/400 450/500+ STR001298 (Q1) STR001298 (Q1) STR001298 (Q1) STR001298 (Q1) STR001300 (Q1) N/A STR001302 (Q1) STR001279 (Q1) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A STR001280 (Q1) STR001318 (Q1) STR001318 (Q1) STR001324 (Q1) STR001324 (Q1) STR001316 (Q1-Q3) STR001317 (Q1-Q3) STR001317 (Q1-Q3) STR001294 (Q1-Q3) STR001336 (Q1-Q6) STR001336 (Q1-Q6) STR001322 (Q1-Q6) STR001322 (Q1-Q3) STR001339 (Q1-Q12) STR001341 (Q1-Q12) STR001342 (Q1-Q12) FU-002029 (F1) FU-002029 (F1) FU-002029 (F1) FU-002029 (F1) FU-002031 (F1) FU-002031 (F1) FU-002031 (F1) FU-002032 (F1) FU-002037 (F1) FU-002038 (F1) FU-002038 (F1) FU-002038 (F1) FU-002039 (F1) FU-002040 (F1) FU-002040 (F1) FU-002101 (F1) FU-002112 (F1) FU-002113 (F1) FU-002114 (F1) FU-000894 (F1) FU-000895 (F1) FU-000895 (F1) FU-002116 (F1) FU-002117 (F1) N/A N/A N/A FAN001066 (B1) FAN001066 (B1) FAN001066 (B1) FAN001066 (B1) FAN001066 (B1,B2) FAN001066 (B1,B2) FAN001065 (B1,B2) FAN001065 (B1,B2) FAN001039 (B1,B2) FAN001039 (B1,B2) FAN001044 (B1,B2) FAN001044 (B1,B2) FAN001044 (B1,B2) FAN001052 (B1,B2) FAN001052 (B1,B2) FAN001056 (B1,B2) FAN001056 (B1,B2) FAN001056 (B1,B2) FAN001056 (B1-B4) FAN001056 (B1-B4) FAN001082 (B1-B5) N/A N/A N/A N/A N/A N/A N/A N/A FAN001043 (B3) N/A FAN001043 (B3) N/A N/A N/A N/A N/A FAN001054 (B4) FAN001054 (B4) FAN001054 (B4) FAN001054 (B4) FAN001054 (B4) FAN001054 (B6,B7) FAN001054 (B6,B7) FAN001054 (B6,B7) Spare Parts F - 3 Notes: A AC and DC Reactor ..........................................................E-6 Accel/Decel ...................................................................... 5-8 Accel/Decel Time C1-01 Acceleration Time 1 ..............................4-12, 5-8 C1-02 Deceleration Time 1 ..............................4-12, 5-8 Alarm Detection ............................................................. 6-10 Alarm Displays and Processing .............................. 6-10 Ambient Temperature ..................................................... 1-11 Analog Output Gain ....................................................... 5-21 H4-02 Terminal FM Gain ....................................... 5-21 H4-05 Terminal AM Gain ....................................... 5-21 Auto-Tuning ................................................................... 4-10 No Rotate Tuning .................................................... 4-11 Standard Tuning ...................................................... 4-10 Terminal Resistance Tuning ................................... 4-11 Auto-Tuning Faults ........................................................ 6-17 Auto-Tuning Fault Displays and Processing ............ 6-17 Auto-Tuning Menu (-A.TUNE-) .................................... 3-13 T1-01 Tuning Mode Selection ................................. 3-14 T1-02 Motor Rated Power ....................................... 3-14 T1-03 Rated Voltage ................................................ 3-14 T1-04 Rated Current ................................................ 3-14 T1-05 Rated Frequency............................................ 3-14 T1-06 Number of Poles............................................ 3-14 T1-07 Rated Speed................................................... 3-14 T1-08 PG Pulses/Rev ............................................... 3-14 B Base Frequency .............................................................. 4-13 Base Voltage ................................................................... 4-13 Braking Transistor Unit(s) Installation ............................................................... 2-15 Adjustments ..................................................... 2-18 Operation Check .............................................. 2-18 Branch Circuit Overload Protection .................................E-5 Branch Circuit Short Circuit Protection ...........................E-2 C Capacity Related Parameters ........................................... B-1 Carrier Frequency ............................................................. 5-9 Carrier Frequency Selection .............................4-12, 5-9 Checking and Controlling the Installation Site ................ 1-11 Coast to stop ..................................................................... 5-6 Communication Connection Terminal ............................ D-3 Communication Specifications ........................................ D-2 Communications .............................................................. D-1 Component Names ............................................ 1-5, 1-6, 3-2 Control Circuit ........................................................................ ..... 1-13, 2-20, 2-21, 2-24, 2-37, 4-3, 4-4, 6-2, 6-3, 6-9, 6-14 Preventive Maintenance ............................................7-3 Terminal Functions ..................................................2-20 +15Vdc power output .......................................2-20 -15Vdc power output ........................................2-20 Add to terminal A1 ...........................................2-20 Analog common ..................................... 2-20, 2-21 Analog input or speed command ......................2-20 Aux. frequency reference 1 ..............................2-20 Digital input photocoupler ...............................2-20 Digital input supply +24Vdc ............................2-20 Digital input supply common ...........................2-20 During run (N.O. contact) ................................2-20 External baseblock N.O. ...................................2-20 External fault input ...........................................2-20 Fault output signal (SPDT) ..............................2-20 Fault reset .........................................................2-20 Forward run/stop command .............................2-20 Frequency agree (N.O. contact) .......................2-20 Jog frequency reference ...................................2-20 Modbus communication input ..........................2-21 Modbus communication output ........................2-21 Multi-step speed reference 1 ............................2-20 Multi-step speed reference 2 ............................2-20 Output current ..................................................2-21 Output frequency ..............................................2-21 Pulse input ........................................................2-21 Pulse monitor ....................................................2-21 Remote/auto operation (N.O. contact) .............2-20 Reverse run/stop command ..............................2-20 Shield wire, optional ground line connection point ........................................2-20 Signal common .................................................2-21 Terminals ........................................................... 1-5, 2-2 Terminal Layout ................................................ 1-5, 2-2 Wire Sizes ................................................................2-24 Wiring Precautions ..................................................2-24 Control circuit failure/damage ..........................................6-3 Control circuit fault ...........................................................6-9 Control Method .................................................................5-2 Control Method Selection ...............................................4-12 Control Wiring ................................................................2-20 D Deceleration Time 1 .......................................................4-12 Delivery Confirmation ..............................................................1-3 Receiving Checks ......................................................1-3 Diagnostics & Troubleshooting ........................................6-1 Digital Operator ................1-5, 1-6, 1-16, 3-1, 4-7, 4-15, 5-3 Index 1 Alarm Detection ...................................................... 6-10 Attaching ................................................................. 1-14 Auto-Tuning Faults ........................................... 6-17, 18 Connection Fault ....................................................... 6-7 Contrast .................................................................. A-35 COPY Function ...................................................... A-37 COPY Function Faults ............................................ 6-19 Display .............................................................3-2, 3-15 Display Scaling ...................................................... A-35 Fault Detection .......................................................... 6-2 Keys ........................................................................... 3-3 Mounting ................................................................. 1-15 Operating Programming Errors (OPE) .................... 6-15 Parameter List .......................................................... A-3 Preventive Maintenance ............................................ 7-3 Removing ................................................................ 1-14 RUN Key ................................................................... 5-4 STOP Key ................................................................. 5-4 Troubleshooting ...................................................... 6-20 DIP Switch S1 ................................................................ 2-22 Drive Capacity Setting Selection ................................................................... B-2 Parameters Affected ................................................. B-3 Drive Date Stamp Information ....................................... 6-31 Drive Enclosure and Revision Code ................................ 1-4 Drive Main Circuit Configurations ................................ 2-10 Drive Main Menus ............................................................ 3-6 Auto-Tuning .............................................................. 3-6 Modified Constants ................................................... 3-6 Operation ................................................................... 3-6 Programming ............................................................. 3-6 Quick Setting ............................................................. 3-6 Drive Mode Indicators ...................................................... 3-4 Drive Model Numbers ...................................................... 1-4 Drive Rating ............................................................. 1-4, B-2 Drive Start-Up Preparation ............................................... 4-2 Drive Start-Up Procedures ............................................... 4-5 Auto-Tuning ............................................................ 4-10 Flux Vector Start-Up ................................................. 4-9 Open Loop Vector Start-Up ...................................... 4-8 V/F Start-Up .............................................................. 4-6 V/F w/ PG Start-Up ................................................... 4-7 Dynamic Braking (DB) .................................................. 2-12 Dynamic Braking Connections General .................................................................... 2-12 Installation ............................................................... 2-12 E Electrical Installation ........................................................2-1 Electromagnetic Compatibility (EMC) ...........................2-26 Cable Installation .....................................................2-26 EMC Directive ................................................................2-26 Recommended EMC Filters ....................................2-28 Enclosure type ..........................................................1-4, C-5 Example of Changing a Parameter .................................3-15 Exterior and Mounting Dimensions ..................................1-7 F F7 Basic Programming Parameters Control Method .........................................................5-2 Description of Parameter Tables ...............................5-2 Fault Detection ..................................................................6-2 Fault Displays and Processing ...................................6-2 Fault History List ...........................................................A-41 Fault Trace List ..............................................................A-41 Field Wiring Diagram .....................................................2-25 Frequency Reference ........................................................3-8 Frequency Reference 1 ...................................................4-12 Frequency Reference 2 ...................................................4-12 Frequency Reference 3 ...................................................4-12 Frequency Reference 4 ...................................................4-12 Frequency Reference Selection ......................................4-12 Front cover ................................................................ 1-5, 1-6 Removing/Attaching ................................................1-14 Function Code ..................................................................D-5 Modbus .....................................................................D-5 G Ground Wiring ................................................................2-11 H Heat Sink .............................................................. 2-12, 6-31 Die-cast ......................................................................1-5 Heat Sink Mount Dynamic Braking Resistor .................2-12 Heat Sink Mount Resistor (ERF) ....................................2-12 Installation ...............................................................2-13 Heatsink Cooling Fan Replacement .................................7-5 Installing the Heatsink Cooling Fan ..........................7-5 Mounting the Heatsink Cooling Fan Assembly ............7-6 Removing the Heatsink Cooling Fan ........................7-5 Removing the Heatsink Cooling Fan Assembly ............7-5 High Frequency (HF) ......................................................2-26 High Speed Operation .....................................................5-14 High Starting Torque ............................................ 5-12, 5-14 Index 2 I Low Frequency (LF) ...................................................... 2-26 Enter Command ......................................................D-16 Error Codes .............................................................D-17 Monitor Data ..........................................................D-11 Reference Data .......................................................D-10 Slave Not Responding ............................................D-17 Modbus Function Code Details Loopback Test (08H) ................................................D-9 Reading/Holding Register Contents (03H) ..............D-8 Write In Several Holding Registers (10H) ...............D-9 Write In Single Holding Register (06H) ..................D-8 Modbus Function Code Details .......................................D-8 Modbus Function Code ....................................................D-5 Modbus Self-Diagnosis .................................................D-18 Modified Constants Menu (-VERIFY-) ..........................3-13 Monitor List ...................................................................A-38 Motor Overload Fault .....................................................5-22 L1-01 Motor Overload Fault Selection ...................5-22 Motor Overload Protection Selection .............................4-14 Motor Rated Current .......................................................4-13 Motor Rated Output ........................................................4-13 Motor Setup ....................................................................5-20 E2-01 Motor Rated Current .....................................5-20 E2-04 Number of Motor Poles ................................5-20 E2-11 Motor Rated Power .......................................5-20 Mounting hole ........................................................... 1-5, 7-4 Multiple Braking Transistor Units ........................ 2-15, 2-17 M N Magnetic Contactor ..........................................................E-6 Main Circuit Configurations ............................................ 2-9 Main Circuit Terminal Functions ..................................... 2-9 Main Circuit Terminals Wiring ....................................................................... 2-3 Applicable Wire Sizes and Closed-loop Connectors ......................................................... 2-3 Recommended Connectors for Terminal Connections ........................................ 2-8 Main Circuit Test Procedure Flowchart ................................................................. 6-28 Main Circuit Test Procedure .......................................... 6-28 Main Menu Structure ........................................................ 3-7 Maintenance ..................................................................... 7-1 Maximum Output Frequency ......................................... 4-13 Maximum Output Voltage .............................................. 4-13 Message Format .............................................................. D-5 Minimum Output Frequency .......................................... 4-13 Modbus Communication ................................................. D-2 Configuration ........................................................... D-2 Modbus Data Tables ...................................................... D-10 Broadcast Data ....................................................... D-16 Nameplate Information ................................................................1-3 Nameplate .............................................................. 1-3, A-16 No Response Message .....................................................D-7 Noise Filter ...................................................................... E-6 Number of Motor Poles ..................................................4-13 Input Voltage Setting..............................................4-13, 5-12 E1-01 Input Voltage Setting .................................... 5-12 Installation Orientation and Clearances ......................... 1-12 Installation Site Checking and Controlling ....................................... 1-11 Specifications .......................................................... 1-11 Installing and Wiring Option Boards ............................. 2-30 Installation ............................................................... 2-31 Option Board Models and Specifications ............... 2-30 PG (Encoder) Feedback Board Terminal Specifications and Wiring Examples ....................... 2-32 PG-A2 .............................................................. 2-32 PG-B2 .............................................................. 2-34 PG-D2 .............................................................. 2-36 PG-W2 ............................................................. 2-38 PG-X2 .............................................................. 2-37 J Jog Frequency Reference ............................................... 4-12 Jumper CN15 .................................................................. 2-22 L O Open Chassis Type ...................................................1-4, C-5 Operation Menu (-DRIVE-) U1 Monitor List..........................................................3-8 U1-01 Frequency Reference ...............................3-8 U1-02 Output Frequency ....................................3-8 U1-03 Output Current ........................................3-8 U1-04 Control Method .......................................3-8 U1-05 Motor Speed ............................................3-8 U1-06 Output Voltage ........................................3-8 U1-07 DC Bus Voltage ......................................3-8 U1-08 Output Power ..........................................3-8 U1-09 Torque Reference ....................................3-8 U1-10 Input Terminal Status ..............................3-8 U1-11 Output Terminal Status ...........................3-8 Index 3 U1-12 Drive Operation Status ...........................3-8 U1-13 Cumulative Operation Time ...................3-8 U1-14 Software Number ....................................3-8 U1-15 Terminal A1 Input Voltage .....................3-8 U1-16 Terminal A2 Input Voltage......................3-8 U1-17 Terminal A3 Input Voltage .....................3-8 U1-18 Motor Secondary Current ......................3-8 U1-19 Motor Excitation Current ........................3-8 U1-20 Output Frequency after Soft-Start ..........3-8 U1-21 ASR Input ...............................................3-8 U1-22 ASR Output ............................................3-8 U1-24 PI Feedback Value ..................................3-8 U1-25 DI-16 H2 Input Status .............................3-8 U1-26 Output Voltage Reference (Vq) ..............3-8 U1-27 Output Voltage Reference (Vd) ..............3-8 U1-28 CPU Number ..........................................3-8 U1-29 kWh (Lower 4 digits) .............................3-8 U1-30 MWh (Upper 5 digits) ............................3-8 U1-32 ACR(q) Output .......................................3-8 U1-33 ACR(d) Output .......................................3-8 U1-34 OPE Detected .........................................3-8 U1-35 Zero Servo Pulse Count ..........................3-8 U1-36 PID Input ................................................3-8 U1-37 PID Output ..............................................3-8 U1-38 PID Setpoint ...........................................3-8 U1-39 Modbus Error Code ................................3-8 U1-40 Cooling Fan Elapsed Time .....................3-8 U1-44 ASR Output with or without Filter ...........3-8 U1-45 Feed Forward Control Output .................3-8 U2 Fault Trace List ...................................................3-9 U2-01 Current Fault ...........................................3-9 U2-02 Previous Fault .........................................3-9 U2-03 Frequency Reference at Fault .................3-9 U2-04 Output Frequency at Fault ......................3-9 U2-05 Output Current at Fault ...........................3-9 U2-06 Motor Speed at Fault ..............................3-9 U2-07 Output Voltage at Fault ..........................3-9 U2-08 DC Bus Voltage at Fault .........................3-9 U2-09 Output Power at Fault .............................3-9 U2-10 Torque Reference at Fault ......................3-9 U2-11 Input Terminal Status at Fault ................3-9 U2-12 Output Terminal Status at Fault ..............3-9 U2-13 Drive Operation Status at Fault ..............3-9 U2-14 Cumulative Operation Time at Fault ..........3-9 U3 Fault History List ..............................................3-10 U3-01 Last Fault ..............................................3-10 U3-02 Fault Message 2 ....................................3-10 U3-03 Fault Message 3 ....................................3-10 U3-04 Fault Message 4 ....................................3-10 U3-05 Elapsed Time 1 .....................................3-10 U3-06 Elapsed Time 2 ..................................... 3-10 U3-07 Elapsed Time 3 ..................................... 3-10 U3-08 Elapsed Time 4 ..................................... 3-10 U3-09 Fault Message 5 .................................... 3-10 U3-10 Fault Message 6 .................................... 3-10 U3-11 Fault Message 7 .................................... 3-10 U3-12 Fault Message 8 .................................... 3-10 U3-13 Fault Message 9 .................................... 3-10 U3-14 Fault Message 10 .................................. 3-10 U3-15 Elapsed Time 5 ..................................... 3-10 U3-16 Elapsed Time 6 ..................................... 3-10 U3-17 Elapsed Time 7 ..................................... 3-10 U3-18 Elapsed Time 8 ..................................... 3-10 U3-19 Elapsed Time 9 ..................................... 3-10 U3-20 Elapsed Time 20 ................................... 3-10 Operation Menu (-DRIVE-) ............................................. 3-8 Operator Programming Errors (OPE) ............................ 6-15 OPE Error Displays ................................................ 6-15 P Parameter Affected by Drive Capacity Setting ......................... B-3 Basic Programming .................................................. 5-2 Copy .......................................................................... 3-2 Description of Parameter Tables .............................. 5-2 Group List ............................................................... 3-12 Motor Parameters .................................................... 3-13 Parameter List .......................................................... A-3 Serial Communication ............................................. D-4 Set/read modified .................................................... 3-13 Setting ..................................................................... 3-12 Part Replacement Guidelines ........................................... 7-4 Periodic Inspection ........................................................... 7-2 Periodic Inspections With no Power Applied ........... 7-2 Periodic Inspections With Power Applied ................ 7-2 Periodic Maintenance of Parts ......................................... 7-4 Peripheral Devices ...........................................................E-6 AC and DC reactor ...................................................E-6 Magnetic Contactor ..................................................E-6 Noise Filter ...............................................................E-6 PG (Encoder) Feedback Board Terminal Specifications and Wiring Examples ............................. 2-32 PG Option ...................................................................... 5-20 F1-01 PG Pulses / Revolution ................................. 5-20 PG Parameter ................................................................. 4-13 Preset Reference ............................................................. 5-11 d1-01 Frequency Reference 1 ................................. 5-11 d1-02 Frequency Reference 2 ................................. 5-11 d1-03 Frequency Reference 3 ................................. 5-11 Index 4 d1-04 Frequency Reference 4 ................................. 5-11 d1-17 Jog Reference ................................................ 5-11 Preventive Maintenance ................................................... 7-3 Flowchart ................................................................... 7-3 Procedure for Setting Up Communication ...................... D-3 Programming Menu (-ADV-) ......................................... 3-12 A1 Initialization ...................................................... 3-12 A2 User Parameters ................................................. 3-12 b1 Sequence ............................................................ 3-12 b2 DC Injection Braking ......................................... 3-12 b3 Speed Search ...................................................... 3-12 b4 Delay Timers ...................................................... 3-12 b5 PID Control ........................................................ 3-12 b6 Reference Hold ................................................... 3-12 b7 Droop control ..................................................... 3-12 b8 Energy Saving .................................................... 3-12 b9 Zero Servo .......................................................... 3-12 C1 Accel/Decel ....................................................... 3-12 C2 S-Curve Accel/Decel ......................................... 3-12 C3 Motor-Slip Compensation ................................. 3-12 C4 Torque Compensation ....................................... 3-12 C5 ASR Tuning ....................................................... 3-12 C6 Carrier Frequency .............................................. 3-12 d1 Preset Reference ................................................. 3-12 d2 Reference Limits ................................................ 3-12 d3 Jump Frequencies ............................................... 3-12 d4 Sequence (MOP & Trim Control) ...................... 3-12 d5 Torque Control ................................................... 3-12 d6 Field-Weakening ................................................ 3-12 E1 V/F Pattern ......................................................... 3-12 E2 Motor Setup ....................................................... 3-12 E3 V/F Pattern 2 ...................................................... 3-12 E4 Motor Setup 2 .................................................... 3-12 F1 PG Option Setup ................................................ 3-12 F2 AI-14 Setup ........................................................ 3-12 F3 DI-08, 16 Setup .................................................. 3-12 F4 AO-08, 12 Setup ................................................ 3-12 F5 DO-02, 08 Setup ................................................ 3-12 F6 Communications Option Setup ........................... 3-12 H1 Digital Inputs ..................................................... 3-12 H2 Digital Outputs .................................................. 3-12 H3 Analog Inputs .................................................... 3-12 H4 Analog Outputs ................................................. 3-12 H5 Serial Communications Setup ........................... 3-12 H6 Pulse I/O Setup .................................................. 3-12 L1 Motor Overload ................................................. 3-12 L2 Power Loss Ridethru .......................................... 3-12 L3 Stall Prevention .................................................. 3-12 L4 Reference Detection ........................................... 3-12 L5 Fault Restart ....................................................... 3-12 L6 Torque Detection ............................................... 3-12 L7 Torque Limit ......................................................3-12 L8 Hardware Protection ..........................................3-12 n1 Hunting Prevention .............................................3-12 n2 AFR Tuning ........................................................3-12 n3 High Slip Braking ...............................................3-12 n5 Feed Forward ......................................................3-12 o1 Monitor Select ....................................................3-12 o2 Key Selections ....................................................3-12 o3 COPY Function ..................................................3-12 T1 Auto-Tuning .......................................................3-12 Protecting the Drive from Foreign Matter ......................1-11 Q Quick Setting Menu (-QUICK-) .....................................3-11 A1-02 Control Method Selection ............................3-11 b1-01 Frequency Reference Selection .....................3-11 b1-02 Run Command Selection ...............................3-11 b1-03 Stopping Method Selection ...........................3-11 C1-01 Acceleration Time 1 .....................................3-11 C1-02 Deceleration Time 1 .....................................3-11 C6-02 Carrier Frequency Selection .........................3-11 d1-01 Frequency Reference 1 ..................................3-11 d1-02 Frequency Reference 2 ..................................3-11 d1-03 Frequency Reference 3 ..................................3-11 d1-04 Frequency Reference 4 ..................................3-11 d1-17 Jog Reference ................................................3-11 E1-01 Input Voltage Setting ....................................3-11 E1-03 V/F Pattern Selection ....................................3-11 E1-04 Maximum Output Frequency ........................3-11 E1-05 Maximum Output Voltage ............................3-11 E1-06 Base Frequency .............................................3-11 E1-09 Minimum Output Frequency ........................3-11 E1-13 Base Voltage .................................................3-11 E2-01 Motor Rated Current .....................................3-11 E2-04 Number of Motor Poles ................................3-11 E2-11 Motor Rated Output ......................................3-11 F1-01 PG Pulses / Revolution .................................3-11 F1-21 PG Pulse / Revolution 2 ................................3-11 F1-22 PG Rotation Selection ...................................3-11 H4-02 Terminal FM Gain Setting ...........................3-11 H4-05 Terminal AM Gain Setting ...........................3-11 L1-01 Motor Overload Protection Selection .............3-11 L3-04 Stall Prevention Selection During Decel ............3-11 Quick Setting Parameters ...............................................4-12 R Remote Mount Resistor Unit Installation Using Internal Braking Transistor............2-14 Remote Mount Resistor Unit(s) Installation ...............................................................2-15 Index 5 REMOTE Reference (REF) Indicator .............................. 3-5 REMOTE Sequence (SEQ) Indicator ............................... 3-4 Revision Code .................................................................. 1-4 Run Command Source ...................................................... 5-4 b1-02 Run Source Selection ...................................... 5-4 2-Wire Control ................................................... 5-4 3-Wire Control ................................................... 5-4 Run Command Selection ................................................ 4-12 Run Indicator .................................................................... 3-5 Terminal cover ..................................................................1-6 Attaching .................................................................1-13 Removing ................................................................1-13 Removing and Attaching .........................................1-13 Terminal FM Gain Setting ..............................................4-14 Terminal Numbers and Wire Sizes .................................2-21 Top protective cover .........................................................1-5 Trial Run .........................................................................4-15 Troubleshooting ..............................................................6-20 S V Serial Communication Parameters ................................................................ D-4 Sinking/Sourcing Mode .................................................. 2-23 Slave Address .................................................................. D-5 Spare Parts ........................................................................F-1 Primary Spare Parts ...................................................F-2 SPEC number ................................................................... 1-4 Specifications .................................................................. C-1 Common ................................................................... C-5 Speed Command Source .................................................. 5-3 b1-01 Reference Source Selection ............................ 5-3 Stall Prevention .............................................................. 5-23 L3-04 Stall Prevention During Deceleration Selection ............................................ 5-23 Stall Prevention Selection During Decel ........................ 4-14 Standard Drive Specifications ......................................... C-2 Stop Indicator ................................................................... 3-5 Stopping Method .............................................................. 5-5 b1-03 Stopping Method Selection ............................. 5-5 Stopping Method Selection .....................................4-12, 5-5 Coast to Stop ............................................................. 5-6 Coast to Stop with Timer .......................................... 5-7 DC Injection to Stop .................................................. 5-7 Ramp to Stop ............................................................. 5-5 V/F Pattern ......................................................................5-12 E1-03 V/F Pattern Selection ....................................5-12 E1-04 Maximum Output Frequency ........................5-15 E1-05 Maximum Output Voltage ............................5-15 E1-06 Base Frequency .............................................5-15 E1-09 Minimum Output Frequency ........................5-15 E1-13 Base Voltage .................................................5-15 V/F Pattern Selection ......................................................5-12 V/F Pattern Voltage Upper Limit ...................................5-13 W Wire Size for Remote Mount Resistor Unit and Braking Transistor Unit ...................................2-15 Wire Sizes and Connector Specifications .........................2-3 Wiring Checks ................................................................2-24 Wiring Diagram ..............................................................2-25 Wiring Terminal Blocks .................................................2-40 Wire Sizes (Same for All Models) ..........................2-40 Wiring Method and Precautions ..............................2-40 T Terminal AM Gain Setting ............................................. 4-14 Terminal Arrangement ..............................................1-5, 1-6 Terminal Block Configuration ......................................... 2-2 Terminal Card ................................................................... 7-7 Mounting the Terminal Card ..................................... 7-7 Removing the Terminal Card .................................... 7-7 Terminal Connections Recommended Connectors ........................................ 2-8 Terminal Connections .................................................... 2-19 Index 6 Drives Technical Support in USA and Canada Technical Support for Inverters and Drives is available by phone as follows: Normal: Monday through Friday during the hours of 8 a.m. to 5:00 p.m. C.S.T. Emergency: After normal hours, 7 days a week including weekends and holidays To contact Drives Technical Support, please call 1-800-YASKAWA (927-5292). From the menu, dial 2 for Technical Assistance, then 1 for Technical Assistance on Variable Frequency Drives. Drives Technical Support can also be reached by e-mail at DriveSupport@yaskawa.com. Support information, such as technical manuals, FAQs, instruction sheets and software downloads are available at our website, www.yaskawa.com. When calling for technical support, please have the following materials available: • The appropriate Technical Manual in hand because the support associate may refer to this • Complete nameplate information from the drive and the motor. (Confirm that Drive Nameplate Output amps is equal to or greater than Motor Nameplate amps) • A list with your parameter settings • A sketch of the electrical power train, from AC line to motor, including filters and disconnects Field Service, Start Up Assistance, Factory Repair, Replacement Parts, and Other Support Contact Drives Technical Support for help with any of these needs. Technical Training Training is conducted at Yaskawa training centers, at customer sites, and via the internet. For information, visit www.yaskawa.com or call 1-800-YASKAWA (927-5292). From the phone menu, dial 4 for Product Training, then 1 for Product Training. Support in Other Countries Yaskawa is a multi-national company with offices and service representation around the world. To obtain support, always contact the local distributor first for guidance and assistance. Contact the closest Yaskawa office listed for further assistance. F7 Drive YASKAWA ELECTRIC AMERICA, INC. Drives Division 16555 W. Ryerson Rd., New Berlin, WI 53151, U.S.A. Phone: (800) YASKAWA (800-927-5292) Fax: (847) 887-7310 Internet: http://www.yaskawa.com YASKAWA ELECTRIC AMERICA, INC. Chicago-Corporate Headquarters 2121 Norman Drive South, Waukegan, IL 60085, U.S.A. Phone: (800) YASKAWA (800-927-5292) Fax: (847) 887-7310 Internet: http://www.yaskawa.com MOTOMAN INC. 805 Liberty Lane, West Carrollton, OH 45449, U.S.A. Phone: (937) 847-6200 Fax: (937) 847-6277 Internet: http://www.motoman.com YASKAWA ELECTRIC CORPORATION New Pier Takeshiba South Tower, 1-16-1, Kaigan, Minatoku, Tokyo, 105-0022, Japan Phone: 81-3-5402-4511 Fax: 81-3-5402-4580 Internet: http://www.yaskawa.co.jp YASKAWA ELETRICO DO BRASIL COMERCIO LTDA. Avenida Fagundes Filho, 620 Bairro Saude Sao Paolo-SP, Brasil CEP: 04304-000 Phone: 55-11-5071-2552 Fax: 55-11-5581-8795 Internet: http://www.yaskawa.com.br YASKAWA ELECTRIC EUROPE GmbH Am Kronberger Hang 2, 65824 Schwalbach, Germany Phone: 49-6196-569-300 Fax: 49-6196-888-301 MOTOMAN ROBOTICS AB Box 504 S38525, Torsas, Sweden Phone: 46-486-48800 Fax: 46-486-41410 MOTOMAN ROBOTEC GmbH Kammerfeldstrabe 1, 85391 Allershausen, Germany Phone: 49-8166-900 Fax: 49-8166-9039 YASKAWA ELECTRIC UK LTD. 1 Hunt Hill Orchardton Woods Cumbernauld, G68 9LF, Scotland, United Kingdom Phone: 44-12-3673-5000 Fax: 44-12-3645-8182 YEA Document Number: TM.F7.01 08/1/08 Rev: 08-08 Data subject to change without notice. Yaskawa Electric America, Inc. YASKAWA ELECTRIC KOREA CORPORATION Paik Nam Bldg. 901 188-3, 1-Ga Euljiro, Joong-Gu, Seoul, Korea Phone: 82-2-776-7844 Fax: 82-2-753-2639 YASKAWA ELECTRIC (SINGAPORE) PTE. LTD. Head Office: 151 Lorong Chuan, #04-01, New Tech Park Singapore 556741, Singapore Phone: 65-282-3003 Fax: 65-289-3003 TAIPEI OFFICE (AND YATEC ENGINEERING CORPORATION) 10F 146 Sung Chiang Road, Taipei, Taiwan Phone: 886-2-2563-0010 Fax: 886-2-2567-4677 YASKAWA JASON (HK) COMPANY LIMITED Rm. 2909-10, Hong Kong Plaza, 186-191 Connaught Road West, Hong Kong Phone: 852-2803-2385 Fax: 852-2547-5773 BEIJING OFFICE Room No. 301 Office Building of Beijing International Club, 21 Jianguomanwai Avenue, Beijing 100020, China Phone: 86-10-6532-1850 Fax: 86-10-6532-1851 SHANGHAI OFFICE 27 Hui He Road Shanghai 200437 China Phone: 86-21-6553-6600 Fax: 86-21-6531-4242 SHANGHAI YASKAWA-TONJI M & E CO., LTD. 27 Hui He Road Shanghai 200437 China Phone: 86-21-6533-2828 Fax: 86-21-6553-6677 BEIJING YASKAWA BEIKE AUTOMATION ENGINEERING CO., LTD. 30 Xue Yuan Road, Haidian, Beijing 100083 China Phone: 86-10-6232-9943 Fax: 86-10-6234-5002 SHOUGANG MOTOMAN ROBOT CO., LTD. 7, Yongchang-North Street, Beijing Economic & Technological Development Area, Beijing 100076 China Phone: 86-10-6788-0551 Fax: 86-10-6788-2878 YEA, TAICHUNG OFFICE IN TAIWAIN B1, 6F, No.51, Section 2, Kung-Yi Road, Taichung City, Taiwan, R.O.C. Phone: 886-4-2320-2227 Fax:886-4-2320-2239
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Page Mode : UseOutlines XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0 (Windows) Creator Tool : FrameMaker 7.2 Modify Date : 2008:08:21 17:11:11-05:00 Create Date : 2008:08:06 11:01:49Z Metadata Date : 2008:08:21 17:11:11-05:00 Format : application/pdf Title : TM_F7_01_06Aug2008.book Creator : michael_hall Document ID : uuid:9ece00f2-0774-4836-86b0-192f36230bd4 Instance ID : uuid:dafbda70-fb71-4af4-bf0a-1581ce441c0b Page Count : 255 Page Layout : SinglePage Author : michael_hallEXIF Metadata provided by EXIF.tools