TORK Catalog Dec 2011

User Manual: TORK-Catalog-Dec-2011

Open the PDF directly: View PDF PDF.
Page Count: 158 [warning: Documents this large are best viewed by clicking the View PDF Link!]

A DIVISION OF NSi INDUSTRIES, LLC
PRODUCT CATALOG
2011
NSi INDUSTRIES, LLC • USA • 800.321.5847 • www.nsiindustries.com
responsible
energy
http://waterheatertimer.org/Tork-Digital-timers-and-manuals.html
About Us
Since 1975, NSis strength is in the unique products that we bring to
the market, combined with our exceptional ability to provide quality
TORK® brand products manufactured in the company’s Mount Vernon
facility. TORK® is NSi Industries largest brand, covering the categories of
Electromechanical and Digital Time Switches, Signaling and Alert Devices,
Pool and Spa Controls, Residential Timers, Photocontrols and Occupancy
Sensors.
For over 85 years, TORK brand recognition and reputation for quality and
design make it the most specified brand in the industry. The TORK brand
has a rich history beginning in the 1920s when the company introduced
the first electromechanical time switch to the marketplace. Currently, TORK’s
time switches maintain energy efficiency through lighting control in such
high profile places as the Empire State Building, Washington DC Parks and
Recreation, The Triborough Bridge, The Met Life Building and many more
institutions across the country. As the most specified brand of time switches in the
industry, TORK enjoys the hearty respect of engineers and project planners
across all channels of distribution.
In the past several years, we’ve introduced a number of TORK time
switches, in-wall and plug-in timers to meet increasingly specific needs in
the marketplace. We’ve also added a line of installer-friendly pool and
spa panels and time switches, and are proud to offer essential pool safety
products that meet and exceed federal requirements for safe pools. We
look forward to designing and engineering more of our Responsible Energy
products, helping save money and the environment through responsible and
minimal use of energy.
NSi Industries LLC
TABLE OF CONTENTS
ENERGY CODE REFERENCE GUIDE ..............7
QUICK LOOK FEATURES & COMMON FEATURES....11
2100 SERIES ............................13
2110 SERIES ............................14
2000 SERIES ............................15
2001 SERIES ............................16
2020 SERIES ............................17
3000 SERIES ............................18
5000M SERIES ...........................19
2005A, 2007A, 2008A SERIES ...............20
5200 SERIES ............................21
5400 SERIES ............................22
5737 SERIES ............................23
PHOTOCONTROL ACCESSORIES ...............24
QUICK LOOK FEATURES & COMMON FEATURES....27
TU40 SERIES.............................29
1100 SERIES ............................31
7000 SERIES ............................33
7000Z SERIES............................35
8000 SERIES, DUTY CYCLE ..................37
8000 SERIES, REPEATING VARIABLE CYCLE.......39
WH2 ..................................40
1800 SERIES ............................41
W SERIES ...............................43
T900 SERIES ............................45
TW SERIES ..............................47
TZ SERIES...............................49
ELECTROMECHANICAL ENCLOSURES
& DIMENSIONS..........................153
QUICK LOOK FEATURES.....................53
DTU40 .................................55
DTWH40 ...............................55
E SERIES................................57
E-PB SERIES .............................57
EW SERIES ..............................59
EWZ SERIES .............................61
DG100 SERIES ...........................63
DZS SERIES..............................65
DTS SERIES..............................67
DW SERIES ..............................69
DZM SERIES .............................71
ELC SERIES, 1 & 2 ZONE ....................73
ELC SERIES, 4, 8 &12 ZONE .................75
LC200 SERIES............................77
DGU SERIES .............................79
DGLC SERIES.............................79
DLC400BP ..............................81
LD SERIES...............................83
DGS SERIES .............................85
EJWT & E500T SERIES......................87
DIN SERIES..............................89
SMC ...................................91
5401 SERIES ............................92
HPS STARTER ............................93
TRP SERIES..............................94
DIGITAL ENCLOSURES & DIMENSIONS .........153
QUICK LOOK FEATURES.....................97
SS720A SERIES...........................98
SS700Z SERIES...........................99
SS721Z SERIES...........................99
701A SERIES ...........................101
711A SERIES ...........................101
SSA SERIES.............................102
SS SERIES..............................103
PHOTOCONTROLS
DIGITAL
ELECTROMECHANICAL
IN-WALL TIMERS
TABLE OF CONTENTS
WARNING LIGHTS, INDUSTRIAL..............135
WARNING LIGHTS, VEHICULAR ..............136
POWER SUPPLY UNITS.....................137
TRANSFORMERS .........................137
ACCESSORIES/REPLACEMENT PARTS/DIMENSIONS 138
PP PANEL SERIES TIMERS ..................141
PFP PANEL SERIES TIMERS..................143
1100 SERIES TIMERS......................144
DW200B TIMER .........................145
P1100 SERIES, 24 HOUR
ELECTROMECHANICAL MECHANISMS ..........147
P1100 SERIES, 7 DAY DIGITAL MECHANISMS ....148
JUNCTION BOXES ........................148
STINGL SR-500 & SR-500PS, SVRS ...........149
LAYERS OF PROTECTION ...................150
ANTI-ENTRAPMENT DRAIN COVERS ...........151
MAGNALATCH SELF-LATCHING GATE CLOSURES...152
TRUCLOSE SELF-CLOSING GATE HINGES . . . . . . . .152
POOL&SPA SAFETY ACCESSORIES.............152
ENCLOSURE DIMENSIONS ..................153
ALPHANUMERIC INDEX ....................155
D SERIES ..............................104
A SERIES ..............................105
C SERIES...............................106
SENSOR TECHNOLOGY & PLACEMENT GUIDE ....109
OSWS SERIES ...........................110
OSC15PLS .............................111
OSC12PL ..............................112
OSC5PL ...............................112
OSC20UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113
OSC SERIES.............................114
ELS ..................................115
TRP-U.................................116
400A SERIES ...........................119
400D SERIES ...........................120
600A SERIES ...........................121
600D SERIES ...........................122
800 SERIES ............................123
MECHANICAL STROBE HORNS ...............127
MECHANICAL HORNS .....................127
MULTI-TONE ELECTRONIC HORNS.............128
HEAVY DUTY BELLS ......................128
BELLS & BUZZERS .......................129
CHIMES & CHIME KITS ....................129
WEATHERPROOF MOTOR DRIVEN SIREN .......130
MANUAL FIRE ALARM .....................130
TELEPHONE STROBE ......................131
TELEPHONE HORN .......................131
TELEPHONE RELAY .......................132
WALL CLOCKS...........................132
ELECTRIC DOOR OPENERS ..................133
PUSH-BUTTONS .........................134
OCCUPANCY SENSORS
POOL & SPA
PLUG-IN TIMERS
TORK ALERT
RECEPTION
FRONT PARKING LOT
WAREHOUSE
CONFERENCE ROOM
BREAK
ROOM
ARCHITECTURAL & LANDSCAPING
RESTROOM RESTROOM
OFFICES
OFFICES
OFFICE
OFFICE
OFFICE
DOCKS & BACK
PARKING
LOT
ENERGY CODE
REFERENCE GUIDE
When ambient light levels drop at dusk, lighting is needed to provide safety and
security. BUT: Does all lighting need to be on all night long? The proper selection
of lighting controls is essential to ensuring that energy is only used when needed.
An efficient lighting control design creates zones of light levels that can be varied
by time at night.
Security Lighting (all night): Photocontrols, Photosensor controls
The first zone gives a minimum light level where security is the primary
need. Determine what lighting is necessary, such as building-mounted
wallpacks and a portion of the parking lot lighting. These should be on
from dusk to dawn, and are best controlled by a photosensor device.
Safety & Architectural Lighting (not necessary all night): Photosensor/Time-
based controls, Astronomic controls
The second zone provides a higher light level for safety, when people
are normally present. Maximum levels for the parking lot and all walk-
way lighting are needed. These lights are best controlled by a com-
bination photosensor and time-based device to allow shut-off during
the night. The astronomic-calculated sunset/time control can also be
useful.
Building Facade, Landscape and Signage: Astronomic controls
The third zone covers architectural lighting for building facade or land-
scape and signs. These are best controlled with an astronomic-calculated
sunset/time control.
< Use the Quick Reference Energy
Code Guide for approved products.
EXTERIOR LIGHTING ZONES
ZONE 1: MINIMUM LIGHT LEVEL / DUSK TO DAWN
ZONE 2: HIGHER LIGHT LEVEL / DUSK TO TIME OFF
ZONE 3: ARCHITECTURAL / TIMED DUSK TO TIMED OFF
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
solutions
energy
saving
responsible
energy
< Responsible Energy is the mark
of TORK’s commitment to developing
and manufacturing energy saving,
environmentally friendly products.
Responsible Energy
Each of these marked products have features that decrease
energy consumption and/or damage to the environment by one
or more of the following:
Timed control, Photocontrol and/or Astronomic control of on
and off functions of lighting, fans, pumps and appliances
Timed control of systems or multiple zones of lighting
Photo or occupancy sensing control of lighting
Supercapacitor backup, no batteries to replace or dispose.
Helps meet CA Title 24, ASHRAE , IECC and other
standards for responsible building products
solutions
energy
saving
responsible
energy
TORK 7
RECEPTION
FRONT PARKING LOT
WAREHOUSE
CONFERENCE ROOM
BREAK
ROOM
ARCHITECTURAL & LANDSCAPING
RESTROOM RESTROOM
OFFICES
OFFICES
OFFICE
OFFICE
OFFICE
DOCKS & BACK
PARKING
LOT
The first way to save energy begins with eliminating lighting when it isn't needed.
As with exterior lighting, an efficient design matches controls to the typical use of the
area.
Small Space, Meeting Rooms, Restrooms, Storage Spaces: Occupancy Sensors, Interval Timers
The first zone includes small spaces such as offices, restrooms and storage areas -
places where people may not occupy the space continuously. Individual wall switch
replacement provides low cost installation, with occupancy sensors and interval timers
as the best solution. In the event that wall switches provide proper coverage for the
occupancy sensor, ceiling mounted options are available.
Small Space, Meeting Rooms, Restrooms, Storage Spaces: Time of Day with Override,
Occupancy Sensors
The first zone includes small spaces such as offices, restrooms and storage areas -
places where people may not occupy the space continuously. Individual wall switch
replacement provides low cost installation, with occupancy sensors and interval
timers as the best solution. In the event that wall switches provide proper coverage
for the occupancy sensor, ceiling mounted options are available.
Large of Small Spaces with Natural Light: Light Sensors, Light Sensors with Occupancy,
Astronomic Timers.
A third zone that uses daylighting control can be added to wither of the first two
zones. light sensors can shut off a portion of the lighting when windows or skylights
contribute sufficient natural light to the area. This "harvesting" of light is an
excellent, green way to conserve energy. (NOTE: Energy codes vary on the stated
maximum time, but shorter times can give more energy savings).
INTERIOR LIGHTING ZONES
ZONE 1: SMALL SPACE
ZONE 2: LARGE SPACE
ZONE 3: HARVESTING LIGHT
RECEPTION
FRONT PARKING LOT
WAREHOUSE
CONFERENCE ROOM
BREAK
ROOM
ARCHITECTURAL & LANDSCAPING
RESTROOM RESTROOM
OFFICES
OFFICES
OFFICE
OFFICE
OFFICE
DOCKS & BACK
PARKING
LOT
TORK 8
PHOTOCONTROLS
FEATURES
QUICK LOOK
2100
SERIES
2110
SERIES
2000
SERIES
2001
SERIES
2020
SERIES
3000
SERIES
5000M
SERIES
2005A
SERIES
5200
SERIES
5737
SERIES
Page 13 14 15 16 17 18 19 20 21 23
Mounting Conduit Conduit Conduit Conduit Conduit Flush Turn-Lock Turn-Lock Turn-Lock Turn-Lock
Adjustable Swivel Yes Yes
Housing Die Cast Zinc Die Cast
Aluminum Lexan®Lexan®Lexan®Lexan®UV Stabilized
Plastic
UV Stabilized
Plastic
UV Stabilized
Plastic
UV Stabilized
Plastic
Turn ON Light Level 1 - 5 fc 1 - 5 fc 1 - 5 fc 1 - 5 fc 1 - 5 fc 1 - 5 fc 1 to 3 fc 1 to 3 fc 1.5 fc 5 fc
Adjustable light level
adjustment Yes Yes Yes Yes
Turn OFF Ratio 3:1 3:1 3:1 3:1 3:1 3:1 5:1 3:1 1.5:1 1.5:1
Time Delay ON Yes Yes Yes Yes Yes Yes Yes Instant Instant Instant
Time Delay OFF Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Light Sensor CdS CdS CdS CdS CdS CdS CdS CdS Silicon Diode Silicon Diode
CFL Compatible Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Surge Protection Yes Yes Yes Yes
Photo Timer Yes
TORK 11
CHOICE OF PHOTOCELLS
TOUGH ENCLOSURES CHOICE OF MOUNTING
ORIENTATION
DEPENDABLE PERFORMANCE
TURN-LOCKS MEET ANSI C136.10
Cadmium sulphide, epoxy-
sealed cells. Available in
1
2
and 1".
All conduit and flush mounted
models utilize die-cast zinc,
die cast aluminum, or genuine
Lexan® materials. All turn-lock
models utilize high impact UV
stabilized polypropylene, ABS,
PBT or Lexan® materials.
Models are available in fixed
position or 180° swivel.
Built-in time delay prevents false
switching due to light from passing
highway vehicles, lightning, etc.
Instant response is available in
turn-lock models (5200 Series).
All models meet the current ANSI
requirements for locking-type
prongs and color coded voltage
designations. Locking prongs are
solid brass.
TORK® Photocontrols are
designed and manufactured with
components which adhere to
the highest industry standards.
Trained personnel and in-process
quality procedures ensure that
every unit meets our strictest
quality standards.
Color-Coded Dome
Grey 105-130VAC
Maroon 208-277VAC
Blue 105-285VAC
Yellow 480VAC
Green 347VAC
COMMON FEATURES
TORK 12
TORK 13
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
PHOTOCONTROLS
APPLICATIONS
FEATURES
SPECIFICATIONS
WIRING DIAGRAMS
WIRING DIAGRAMS
ORDERING INFO
CONTACT RATINGS
2100 SERIES
SPECIFICATION GRADE
1/2" CONDUIT MOUNTING
DIE CAST ZINC
PHOTOCONTROL
Parking lot lighting
Building perimeter lighting
Outdoor signage
CATALOG
NO. SWITCH RATING
TUNGSTEN BALLAST
2101 SPST 2000W 1800VA
2104 SPST 2000W 1800VA
2107 SPST 2000W 1800W
CATALOG
NO. UPC
CODE VOLTAGE
50-60Hz
2101 60012 120VAC
2104 60013 208-277VAC
2107 60031 120/277VAC
73866 62020 Mounting Bracket
OPERATION: Delay of up to two minutes
to prevent false switching due to light from
passing vehicles, lightning, etc.
HOUSING: Heavy Duty die cast zinc
housing and base. Gasketed for maximum
weather protection.
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
ON/OFF: Turn ON is 1 to 5fc, Turn OFF is 3
to 15fc, without the slide in position. ON/OFF
adjustment is easily made by moving a slide
cover. No tools required.
TIME DELAY: ON and OFF.
CELL: Cadmium sulphide, epoxy-coated, 1"
diameter.
CONTACTS: Remain closed between dusk and
dawn. (The unit fails in the ON position).
LEAD WIRES: Three color coded, minimum
6” wire leads, #16AWG, rated for 105˚C.
POWER CONSUMPTION:
Averages under 1 watt.
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
FAIL MODE: ON.
WARRANTY: 5 years.
2100 SERIES2000 SERIES
APPLICATIONS
FEATURES
SPECIFICATIONS SPECIFICATIONS
WIRING DIAGRAMS
WIRING DIAGRAMS
ORDERING INFO
CONTACT RATINGS
TORK 14
2110 SERIES
SPECIFICATION GRADE
1/2" CONDUIT MOUNTING
DIE CAST ALUMINUM
PHOTOCONTROL
Parking lot lighting
Building perimeter lighting
Outdoor signage
CATALOG
NO. UPC
CODE VOLTAGE
50-60Hz
2115 60032 120VAC
2116 60033 208-277VAC
2117* 60037 120VAC
73866 62020 Mounting Bracket
OPERATION: Delay of up to two minutes
to prevent false switching due to light from
passing vehicles, lightning, etc.
HOUSING: Die case aluminum housing
and base. Gasketed for weather protection.
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
ON/OFF: Turn ON is 1 to 5fc, Turn OFF is 3
to 15fc, without the slide in position. ON/OFF
adjustment is easily made by moving a slide
cover. No tools required.
TIME DELAY: ON and OFF.
CELL: Cadmium sulphide, epoxy-coated,
1
2
diameter. Model 2117 is 1" cell.
CONTACTS: Remain closed between dusk and
dawn (the unit fails in the ON position).
LEAD WIRES: Three color coded, minimum
6” wire leads, #16AWG, rated for 105˚C. (2117
#10AWG red and black).
POWER CONSUMPTION:
Averages under 1 watt.
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
FAIL MODE: ON.
WARRANTY: 5 years.
CATALOG
NO. SWITCH RATING
TUNGSTEN BALLAST
2115 SPST 2000W 1800VA
2116 SPST 3470-4620W 2080-2770VA
2117* SPST 3000W 3000VA
*Not UL or CSA rated.
2117
2115 & 2116
TORK 15
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
PHOTOCONTROLS
APPLICATIONS
FEATURES
SPECIFICATIONS
WIRING DIAGRAMS
WIRING DIAGRAMS
ORDERING INFO
CONTACT RATINGS
2000 SERIES
1/2" CONDUIT MOUNTING
FIXED POSITION, LEXAN® HOUSING
WITH WEATHERPROOF SEALANT
PHOTOCONTROL
Flood lamp
Patio lamp
Decorative lighting
CATALOG
NO. SWITCH RATING
TUNGSTEN BALLAST
2000 SPST 2000W 1800VA
2000-2 SPST 3470-4620W 2080-2770VA
2000-7* SPST 2000W 1800VA
CATALOG
NO. UPC
CODE VOLTAGE
50-60Hz
2000 60017 120
2000-2 60018 208-277
2000-7* 62023 120/277
73866 62020 Mounting Bracket
OPERATION: Delay up to two minutes to
prevent false switching due to light from
passing vehicles, lightning, etc.
HOUSING: All Lexan® enclosures are
impact and vandal resistant. Translucent
Lexan® Dome prolongs cell life by further
screening out ultraviolet rays. Dome
and base are ultrasonically welded for
maximum strength.
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3
to 15fc, without the slide in position. ON/OFF
adjustment is easily made by moving a slide
cover. No tools required.
TIME DELAY: ON and OFF.
CELL: Cadmium sulphide, epoxy-coated,
1
2
diameter.
CONTACTS: Remain closed between dusk and
dawn. (The unit fails in the ON position).
LEAD WIRES: Three color coded, minimum
6” wire leads, #16AWG, rated for 105˚C.
POWER CONSUMPTION:
Averages under 1 watt.
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
FAIL MODE: ON.
WARRANTY: 5 years.
*Model 2000-7 has a cadmium sulphide, 1” epoxy cell. Also
UL listed and CSA certified.
2100 SERIES
2000 SERIES
APPLICATIONS
FEATURES
SPECIFICATIONS SPECIFICATIONS
WIRING DIAGRAMS WIRING DIAGRAMS
ORDERING INFO
CONTACT RATINGS
TORK 16
2001 SERIES
1/2" CONDUIT MOUNTING
180° SWIVEL, LEXAN® HOUSING
PHOTOCONTROL
Flood lamp
Patio lamp
Decorative lighting
OPERATION: Delay up to two minutes to
prevent false switching due to light from
passing vehicles, lightning, etc.
HOUSING: All Lexan® enclosures are
impact and vandal resistant. Translucent
Lexan® Dome prolongs cell life by further
screening out ultraviolet rays. Dome
and base are ultrasonically welded for
maximum strength.
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3
to 15fc, without the slide in position. ON/OFF
adjustment is easily made by moving a slide
cover. No tools required.
TIME DELAY: ON and OFF.
CELL: Cadmium sulphide, epoxy-coated,
1
2
diameter.
CONTACTS: Remain closed between dusk and
dawn. (The unit fails in the ON position).
LEAD WIRES: Three color coded, minimum
6” wire leads, #16AWG, rated for 105˚C.
POWER CONSUMPTION:
Averages under 1 watt.
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
FAIL MODE: ON.
WARRANTY: 5 years.
CATALOG
NO. SWITCH RATING
TUNGSTEN BALLAST
2001 SPST 2000W 1800VA
2002 SPST 3470-4620W 2080-2770VA
CATALOG
NO. UPC
CODE VOLTAGE
50-60Hz
2001 60015 120
2002 60016 208-277
73866 62020 Mounting Bracket
White Neutral
Black LineRed Lamp
Move Slide for Earlier
or Later Turn ON
(White)
(Black) Line (Red) Lamp
Move Slide for Earlier
or Later Turn ON
240V
L1
L2
For 277VAC:
L1 - Line
L2 - Neutral
TORK 17
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
PHOTOCONTROLS
APPLICATIONS
FEATURES
SPECIFICATIONS
WIRING DIAGRAMS
ORDERING INFO
CONTACT RATINGS
2020 SERIES
1/2" CONDUIT MOUNTING
180° SWIVEL, LEXAN® HOUSING
PHOTOCONTROL
Flood and patio lamps
Decorative lighting
Ideal for applications where it
is essential to aim the photocell
in an exact direction to sense
natural light but avoid artificial
light.
CATALOG
NO. SWITCH RATING
TUNGSTEN BALLAST
2021 SPST 2000W 1800VA
2022 SPST 3470-4620W 2080-2770VA
CATALOG
NO. UPC
CODE VOLTAGE
50-60Hz
2021 60024 120
2022 60025 208-277
73866 62020 Mounting Bracket
OPERATION: Delay up to two minutes to
prevent false switching due to light from
passing vehicles, lightning, etc.
HOUSING: All Lexan® enclosures are
impact and vandal resistant, cover and base
are ultrasonically welded for maximum
strength.
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
ON/OFF: Turn ON is 1 to 5fc. Turn OFF is
3 to 15fc.
TIME DELAY: ON and OFF.
CELL: Cadmium sulphide, epoxy-coated,
1
2
” diameter.
CONTACTS: Normally closed (the unit
fails in the ON position).
LEAD WIRES: Three color coded,
minimum 6” wire leads, #16AWG, rated
for 105˚C.
POWER CONSUMPTION:
Averages under 1 watt.
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
FAIL MODE: ON.
WARRANTY: 5 years.
Neutral
For 277VAC
L1 - Line
L2 - Neutral
(Black) (Red) Lamp
Line
L1
L2
240V
(White)
208-277V
MODELS
Neutral
(Black) (Red) Lamp
Line
(White)
120V
MODELS
APPLICATIONS
FEATURES
SPECIFICATIONS SPECIFICATIONS
WIRING DIAGRAMS
WIRING DIAGRAMS WIRING DIAGRAMS
ORDERING INFO
CONTACT RATINGS
TORK 18
3000 SERIES
FLUSH MOUNTING
LEXAN® HOUSING
PHOTOCONTROL
Pole lanterns
Lawn lighting
Walkways
OPERATION: Delay up to two minutes to
prevent false switching due to light from passing
vehicles, lightning, etc.
HOUSING & MOUNTING: Control housing
is weather-resistant molded Lexan® with
ultrasonically welded seams.
MODEL 3000: Flush mounting through .6875”
hole in post lantern or lighting fixture,
3
8
” NPT,
stem
3
4
” long. Gasket and nut supplied.
MODEL 3010: flush mounting into standard,
raintight junction box. Includes plate and gasket
to fit FS type outdoor junction box.
ENERGY SAVINGS: Works with screw base
CFLs and LED lamps.
ON/OFF: Turn ON is 1 to 5fc. Turn OFF is
3 to 15fc.
TIME DELAY: ON and OFF.
CELL: Cadmium sulphide, epoxy-coated,
1
2
” diameter.
CONTACTS: Normally closed (the unit
fails in the ON position).
LEAD WIRES: Three color coded,
minimum 6” wire leads, #16AWG, rated
for 105˚C.
POWER CONSUMPTION:
Averages under 1 watt.
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
FAIL MODE: ON.
WARRANTY: 5 years.
CATALOG
NO. SWITCH RATING
TUNGSTEN BALLAST
3000 SPST 2000W 1800VA
3002 SPST 3470-4620W 2080-2770VA
3006* SPST 1500W 1200VA
3010 SPST 2000W 1800VA
CATALOG
NO. UPC
CODE VOLTAGE
50-60Hz
3000 60020 120
3002 60019 208-277
3006* 60026 347
3010 60021 120
Flush Mounting
Model 3010
LINE BLK
LAMP
RED
WHITENEUT.
120V
120V
MODEL
LINE BLK
LAMP
RED
WHITE
240V
208-277V
MODEL
For 277VAC:
L1 - Line
L2 - Neutral
*CSA certified only.
SPECIFICATIONS
WIRING DIAGRAMS
CONTACT RATINGS
ORDERING INFO
5000M SERIES
DELAYED RESPONSE UTILITY GRADE
MOV SURGE ARRESTOR
PHOTOCONTROL
For use on streets, highways and
other luminaries equipped with
locking type receptacles, where
most stringent surge protection
is needed.
CATALOG
NO. UPC
CODE VOLTAGE
50-60Hz COLOR
5001M 61012 105-130 Grey
5004M 61013 208-277 Maroon
5007M 61014 105-130/208-285 Blue
5008M* 61017 480 Yellow
5021M 61015 105-130 Grey
5024M 61016 208-277 Maroon
5026M** 61045 347 Green
OPERATION: Delayed response prevents false
switching due to light from vehicles or lighting, etc.
STANDARDS: Meets ANSI C136.10 including color
designations. Also meets EEI NEMA standards.
HOUSING: Lexan® UV Stabilized, permanent color
with UV resistant clear acrylic window. Models 5026M
and 5008M with polypropylene dome. Provides high
impact, flammability resistance and electrically safe
operation.
ENERGY SAVINGS: Works with screw base CFLs
and LED lamps.
ON/OFF: Turn-ON is 1 to 3 fc. Turn-OFF to Turn-ON
ratio is 5 max.
TIME DELAY: ON and OFF.
CELL: Cadmium sulphide photocell responds to the
light spectrum near to that of a human eye. Resists
effects of moisture and airborne contaminants.
RELAY: Bi-metal provides positive snap action
switching, reducing bounce and prolonging contact life.
SURGE ARRESTOR: 380 joule MOV (metal oxide
varistor) exceeds ANSI and NEMA requirements.
LOCKING PRONGS: Solid brass for maximum
corrosion resistance and electrical conductivity.
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
FAIL MODE: ON.
WARRANTY: 3 years.
CATALOG
NO. LIGHT SENSOR RATING
TUNGSTEN BALLAST
5001M 1" 2000W 1800VA
5004M 1" 3470-4620W 2080-2770VA
5007M
1
2
"2000W
3470-4620W
1800VA
2080-2770VA
5008M* 1" 1000W 1800VA
5021M
1
2
"2000W 1800VA
5024M
1
2
"3470-4620W 2080-2770VA
5026M**
1
2
"1000W 1800VA
NL1
Line
(Black)
105 to 285 volt
single phase grounded
supplies and loads
Load (Red)
Load
Neutral
(White)
Receptacle Surface
2 3/16"
2 3/16"
2"
*Not UL listed or CSA certified.
**CSA certified only.
TORK 19
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
PHOTOCONTROLS
APPLICATIONS
FEATURES
SPECIFICATIONS
WIRING DIAGRAMS
TORK 20
STANDARDS: Meets ANSI C136.10
including color designations. Also meets
EEI NEMA standards.
HOUSING: Polypropylene, UV
Stabilized, permanent color with UV
resistant clear acrylic window. Provides
high impact, flammability resistance and
electrically safe operation.
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
ORDERING INFO
CONTACT RATINGS
SPECIFICATIONS
WIRING DIAGRAMS
2005A, 2007A
& 2008A
QUICK RESPONSE
TURN-LOCK MOUNTING
PHOTOCONTROL
For use on streets, highways and
other luminaries equipped with
locking type receptacles, where
instant response is required.
Complies with ANSI C136.10 and
EEI NEMA standards.
ON/OFF: Turn-ON is 1 to 3 fc. Turn-OFF to Turn-
ON is 3 average.
TIME DELAY: Instant ON/3-5 seconds OFF.
CELL: Cadmium sulphide photocell responds to the
light spectrum near to that of a human eye. Resists
effects of moisture and airborne contaminants.
CONTACTS: Solid brass prongs for maximum
corrosion resistance and electrical conductivity.
SURGE ARRESTOR: 360 joules MOV exceeds
NEMA and ANSI requirements.
RELAY: Positive snap action switching, reducing
bounce and prolonging contact life.
TEMPERATURE RANGE:
-40˚ to +158˚F (-40˚ to +70˚C).
FAIL MODE: ON.
WARRANTY: 3 years.
CATALOG
NO.
RATING
TUNGSTEN BALLAST
2005A 1000W 1800VA
2007A 1000W 1800VA
2008A* 1000W 1800VA
Receptacle Surface
2 3/16"
3 3/16"
2"
NL1
Line
(Black)
105 to 285 volt
single phase grounded
supplies and loads
Load (Red)
Load
Neutral
(White)
CATALOG
NO. UPC
CODE VOLTAGE
50-60Hz COLOR
2005A 62012 105-130 Grey
2007A 62013 105-285 Blue
2008A* 62014 400-550 Yellow
*Not UL or CSA listed.
APPLICATIONS
FEATURES
TORK 21
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
PHOTOCONTROLS
APPLICATIONS
FEATURES
SPECIFICATIONS
WIRING DIAGRAMS
ORDERING INFO
CONTACT RATINGS
5200 SERIES
UTILITY GRADE ELECTRONIC
WITH FAIL ON MODE
PHOTOCONTROL
For use where the extreme
accuracy and reliability of
an electronic photocontrol is
required and in the event of
failure, light should stay ON for
safety reasons.
CATALOG
NO. UPC
CODE VOLTAGE
50-60Hz
5231 78885 105-130VAC
5237 78886 105-305VAC
STANDARDS: Meets ANSI C136.10
including color designations. Also meets EEI
NEMA standards.
HOUSING: UV stabilized, ANSI color-
coded, high impact polypropylene dome.
Cross-linked polypropylene gasket. High
impact ABS base. High impact, UV stabilized
acrylic window.
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
ON/OFF: Turn ON is 1.5 foot candle +/- 0.2 OFF/ON
ratio is 1.5:1 average*.
TIME DELAY: Instant ON/3-5 second OFF*.
CELL: Silicon photosensor assures drift-free operation,
turning on and off at the same light level consistently
throughout the life of the unit.
CONTACTS: DC relay has positive snap action switching,
reducing bounce and prolonging contact life. Fail ON for
safety.
SURGE ARRESTOR: 920 joule MOV (metal oxide
varistor) exceeds ANSI and NEMA requirements.
LOCKING PRONGS: Solid brass for maximum corrosion
resistance and electrical conductivity.
POWER CONSUMPTION: 1.0 watt average @ 120V.
TEMPERATURE RANGE:
-40˚ to +158˚F (-40˚ to +70˚C).
FAIL MODE: ON.
WARRANTY: 5 years.
*Consult factory for other ratios and time delays.
CATALOG
NO. LIGHT SENSOR RATING
TUNGSTEN BALLAST
5231 Silicon Photosensor 1000W 1800VA
5237 Silicon Photosensor 1000W 1800VA
Receptacle Surface
2 3/16"
3 1/8"
2"
NL1
Line
(Black)
105-305 VAC
single phase grounded supplies and loads
Load (Red)
Load
Neutral
(White)
NL1
Line
(Black)
105 to 285 volt
single phase grounded
supplies and loads
Load (Red)
Load
Neutral
(White)
ORDERING INFO
APPLICATIONS
FEATURES
SPECIFICATIONS
CONTACT RATINGS
TORK 22TORK 22
SPECIFICATIONS
WIRING DIAGRAMS
TORK 22
WIRING DIAGRAMS
5400 SERIES
6000 WATT CONTACTORS
WITH TURN-LOCK
PHOTOCONTROL
For street lighting. Controls all
lighting loads in excess of the
capacity of the photoelectric
control contacts.
CATALOG
NO. UPC
CODE PHOTOCONTROL
INCLUDED VOLTAGE
50-60Hz
5403 60009 5021M 105-130VAC
5404 60010 5024M 208-240VAC
5404-3 60011 5024M 277VAC
5420 60014 5021M 105-130VAC
HOUSING: Outdoor NEMA Type 3R. Beige
enamel finish. Two
1
2
”–
3
4
” combination
KO in bottom.
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
RECEPTACLE: 3-prong turn-lock meets the
requirements of EEI NEMA.
POWER CONSUMPTION: Maximum 3 watts
during daylight.
CATALOG
NO. SWITCH CONTACT RATING
PER POLE
5403 DPST 3000W
5404 DPST 3000W
5404-3 DPST 3000W
5420 SPDT 1000W
LOAD
WHT
WHT
120V
H
N
BLK RED
LOAD LOAD
WHT
WHT
120V
120V
H
H
N
BLK RED
LOAD
120V 2-WIRE SYSTEM 120V/240V 3-WIRE SYSTEM
LOAD
WHT
WHT
277V/480V 4-WIRE SYSTEM
277V
H
N
BLKRED
LOAD
WHT
WHT
208V/240V 4-WIRE SYSTEM
208V or 240V
H
H
BLKRED
LOAD
277 VOLT CIRCUIT
MODEL
5404-3
120 VOLT CIRCUIT
MODEL
5403
208 or 240 VOLT
CIRCUIT
MODEL 5404
WHT
WHT
BLK
120V
H
N
BLK
RED
RED
BLUE
LOAD 1 CLOSES AT DUSK, OPENS AT DAWN
LOAD 2 CLOSES AT DAWN, OPENS AT DUSK
LOAD 2
LOAD 1
Add photoelectric control dimensions
2" high x 3" diameter
4-1/2"
(114mm) 3-13/32"
(87mm)
7-1/4"
(184mm)
CASE
DIMENSIONS
120 VOLT CIRCUIT
MODEL
5420
LOAD
WHT
WHT
120V
H
N
BLK RED
LOAD LOAD
WHT
WHT
120V
120V
H
H
N
BLK RED
LOAD
120V 2-WIRE SYSTEM 120V/240V 3-WIRE SYSTEM
LOAD
WHT
WHT
277V/480V 4-WIRE SYSTEM
277V
H
N
BLKRED
LOAD
WHT
WHT
208V/240V 4-WIRE SYSTEM
208V or 240V
H
H
BLKRED
LOAD
277 VOLT CIRCUIT
MODEL
5404-3
120 VOLT CIRCUIT
MODEL
5403
208 or 240 VOLT
CIRCUIT
MODEL 5404
WHT
WHT
BLK
120V
H
N
BLK
RED
RED
BLUE
LOAD 1 CLOSES AT DUSK, OPENS AT DAWN
LOAD 2 CLOSES AT DAWN, OPENS AT DUSK
LOAD 2
LOAD 1
Add photoelectric control dimensions
2" high x 3" diameter
4-1/2"
(114mm) 3-13/32"
(87mm)
7-1/4"
(184mm)
CASE
DIMENSIONS
120 VOLT CIRCUIT
MODEL
5420
TORK 23
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
PHOTOCONTROLS
APPLICATIONS
FEATURES
SPECIFICATIONS
WIRING DIAGRAMS
ORDERING INFO
CONTACT RATINGS
5737 SERIES
ON AT DUSK, OFF AT MIDNIGHT
ON EARLY MORNING,
OFF AT DAWN
PHOTO-TIMERS
Offices
Restaurant signage
Billboards
Landscape and yard lighting
Ideal for situations when visible
traffic is reduced – lights ON at
dusk and OFF at 11pm or later,
then on again for early morning
illumination.
CATALOG
NO. UPC
CODE VOLTAGE
50-60Hz
5737TZ 62010 105-305VAC
5737TM 62009 105-305VAC
OPERATION: Microprocessor tracks the
dusk and dawn times with the seasons and
automatically determines midnight, NO
PROGRAMMING REQUIRED. Automatically
"re-learns" and resets after power outage,
eliminating costly maintenance. DST correction
built in.
HOUSING: UV stabilized, ANSI color-coded
polypropylene dome. UV stabilized, clear acrylic
window. ABS base. Cross-linked, polypropylene
gasket.
ENERGY SAVINGS: Works with screw base
CFLs and LED lamps.
ON/OFF: Turn ON at dusk is 5.0 foot candle +/- 0.5 OFF/
ON ratio is 1.5:1 average.
TIME DELAY: Instant ON/3-5 seconds OFF.
CELL: Silicon photosensor
Midnight OFF: Allows user to adjust OFF time during the
night. OFF time can be set for up to two hours before (for
extra energy savings) or up to two hours after midnight.
Use to stagger groups of lights to go OFF at different times
during the night.
Early Morning ON (537TZ only): Allows user to set number
of hours after midnight (from 2-10 hours) that lights
should turn back ON.
CONTACTS: DC Relay, normally closed. Provides chatter
free operation. Solid brass Prongs for maximum corrosion
resistance and electrical conductivity.
TEMPERATURE RANGE:
-40˚ to +158˚F (-40˚ to +70˚C).
FAIL MODE: ON.
WARRANTY: 3 years.
Receptacle Surface
2 3/16"
3 1/8"
2"
NL1
Line
(Black)
105-305 VAC
single phase grounded supplies and loads
Load (Red)
Load
Neutral
(White)
Receptacle Surface
2 3/16"
3 1/8"
2"
NL1
Line
(Black)
105-305 VAC
single phase grounded supplies and loads
Load (Red)
Load
Neutral
(White)
FOR 240V, N=L2, L1=L1
120 or
277V
CATALOG
NO. SWITCH RATING
TUNGSTEN BALLAST
5737TZ SPST 1000W 1800VA
5737TM SPST 1000W 1800VA
SPECIFICATIONS
WIRING DIAGRAMS
TORK 24
PHOTOCONTROL
ACCESSORIES
FOR TURN-LOCK CONTROLS
5500 replaces photocontrol to change light fixture to always ON. 5500-OC
replaces photocontrol to change light fixture to always OFF. Durable materials
and gasket provide longevity and weatherproof protection.
120-480V receptacle with color-coded #14 leads, mounting bracket and one
mounting screw.
120-480V receptacle with color-coded #14 leads, neoprene gasket and two
mounting screws.
120-480V receptacle with color-coded #14 leads, plastic housing, lock nut (with
1
2
" NPT) and a mounting bracket.
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION
5500 61130
Shorting cap
480VAC max
1800 Tungsten
1800VA Ballast
5500-OC 61132 Open cap
480VAC max
(Black housing)
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION
2224 61026 Receptacle and mounting
bracket
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION
2223 61025 Receptacle with Neoprene
gasket
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION
2421 61021 Receptacle with plastic
housing and bracket
REPLACEMENT CAPS RECEPTACLE
RECEPTACLE
RECEPTACLE
The TORK Photo-timer Plus is the most flexible photocontrol ever,
operating like a photocontrol AND a time switch! Ideal for retrofit without
expensive rewiring. The unit turns the load ON at sunset and can be preset
to turn the load OFF up to two hours before or two hours after midnight.
It can also be set to turn the load back ON from two to ten hours after
midnight and OFF at dawn.
No programming is required, the microprocessor tracks dusk and dawn
times and automatically determines midnight, and corrects for Daylight
Savings Time. It even re-learns and resets itself after a power outage, so that
no maintenance is ever needed.
THE MOST FLEXIBLE PHOTO-TIMER FOR MAXIMUM
ENERGY SAVINGS AND ALL ON/OFF NEEDS!
TORK® 5737TZ PHOTO-TIMER
DUSK ON
MIDNIGHT OFF
EARLY MORNING ON
DAWN OFF
ELECTROMECHANICAL
TIME SWITCHES
FEATURES
QUICK LOOK
SERIES PAGE
NO.
CLOCK
DIAL
MINIMUM
SETTINGS
(MINUTES)
SKIP
A
DAY
MANUAL
OVERRIDE
SUNRISE/
SUNSET
MAX ON
& OFF
EVENTS
PER DAY
SWITCH TYPES RATINGS
(AMPS)
RESERVE
POWER
ON OFF
TU40 29 24 Hour 15 15 Permanent 48 SPST DPST SPDT DPDT 40
1100 31 24 Hour 20 75 Yes 12 SPST DPST 40
7000 33 24 Hour 20 75 Yes Yes 12 SPST DPST SPDT DPDT 3PST 40 Available
7000Z 35 24 Hour 20 or 40
Minute Offset Yes Yes Astronomic 1 SPST DPST SPDT DPDT 3PST 40 Available
TZ 49 24 Hour 20 or 40
Minute Offset Yes Permanent
by circuit Astronomic 1 DPDT 3PST 20 Standard
W 43 7 Day 60 120 Yes Yes 2 SPST DPST SPDT DPDT 3PST
4PST 40 Available
TW 47 7 Day 60 120 Yes Permanent
by circuit 2 DPDT 3PST 20 Standard
T900 45 7 Day 60 120 Yes Permanent
by circuit
Photo
Control 22 SPDT
3 SPDT 20 Standard
1847A 41 24 Hour 20 75 Yes 12 SPDT, Momentary Contact 10 Available
1847AZ 41 24 Hour 20 or 40
Minute Offset Yes Yes Astronomic 1 SPDT, Momentary Contact 10 Available
1847AW 41 7 Day 60 120 Yes Yes 2 SPDT, Momentary Contact 10 Available
8000 37 24 Hour 15 15 Available 48 SPDT 20 Available
8000 39 6, 12, 30
& 60 Min.
Varies by dial
6 sec. to 1 min. 30/dial SPDT 20
WH2 40 24 Hour 20 75 Yes 12 DPST 40
TORK
27
FIELD UPGRADEABLE
ASTRONOMIC DIALS
All Tork 24 Hour Time Switches can
be upgraded in the field to astronomic
operation.
EASY TO SET DIAL ASSEMBLY
Tork’s 24 hour dial assembly allows the user
to set the time switch more accurately, easily
moving it by hand in small increments. Dial
can provide up to 12 ON/OFFs per day with
cycles as short as 20 minutes. AM and PM
settings are easy to see by the light and dark
areas of the dial.
CAPTIVE TABS DUTY CYCLE DIAL
For applications requiring many ON/OFF
cycles per day, captive tabs on this dial tilt
in and out just using your fingertip!
SPRING WOUND RESERVE
During power outages, precision spring
mechanism takes over instantly and
automatically. Keeps the mechanism on
time up to 16 hours on 24 hour models
and up to 24 hours on 7 day models.
No resetting is needed after power
resumes, and field installation is easy!
ENCLOSED MOTOR
Time switch motors are enclosed to
protect from dust and damage.
REMOVABLE DOOR
Tork time switches feature removable
doors to provide easy access for
installation and wiring.
TORK® Electromechanical
Controls are designed and
manufactured with components
which adhere to the highest
industry standards. Trained
personnel and in-process quality
procedures ensure that every
unit meets our strictest quality
standards.
COMMON FEATURES
TORK
28
TORK 29
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
ELECTROMECHANICAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
TU40 SERIES
UNIVERSAL MULTI-VOLTAGE
SAME ON/OFF TIMES EACH DAY
24 HOUR TIME SWITCH
CATALOG
NO. UPC
CODE TIMER SUPPLY
(VAC) 60Hz DRY CONTACTS
(UNPOWERED) ENCLOSURE
TYPE
TU40 24000 120/208-240/277 DPDT Plastic Indoor/Outdoor
NEMA 3R
TU40-Y 24001 120/208-240/277 DPDT Metal Indoor
NEMA 1
NEW!
Lighting
Pumps
Signs
Air conditioning
Water heaters
Fans
MULTI-VOLTAGE: Automatic input voltage
detection.
EASY SET: Real time clock face and day/night
markings for setting trippers.
SCHEDULING: Minimum ON is setting 15
minutes. Dial has 96 captive trippers.
4 in 1 CONTACTS: DPDT can also wire as SPST,
SPDT, & DPST.
BYPASS SWITCH: Sets timer to permanent
ON, OFF or timer operation.
VACATION MODE: Set timer OFF with no
change of tripper settings.
INDICATING LIGHTS: Power ON green and
load ON red and LED indicators.
MORE WIRING
SPACE!
TORK 30
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
INPUT VOLTAGE: 120/208-240/277VAC,
60Hz (auto detection).
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #18 AWG.
OPERATING TEMPERATURE:
-31°F to 116°F (-35°C to +47°C).
POWER CONSUMPTION: 6 watts maximum.
ENCLOSURE: Polycarbonate Indoor/Outdoor
NEMA 3R or -Y suffix metal indoor NEMA 1
enclosure. Both with lockable hasp standard (see
page 153 for enclosure dimensions).
TYPE VOLTAGE RATING
NO NC
General Purpose 120-277VAC 40A 30A
Inductive 120-277VAC 30A 15A
Ballast 120VAC 30A 10A
277VAC 20A 10A
Tungsten 120VAC 15A
Motor Load 120VAC 1HP, 30FLA, 90LRA ¼HP, 12FLA, 30LRA
240VAC 2HP, 20FLA, 60LRA ½HP, 12FLA, 33LRA
Pilot Duty 120VAC 720VA 290VA
240VAC 720VA 360VA
Resistive 28VDC 20A
Max above 104°F 120-277VAC 30A
N
LN
NC NO C
LN
NC NO C
LN
Typical Wiring Diagram, 120 VAC Application
HN
L1 L2
NC NO C
L1
NC NO C
L2
TIMER
SUPPLY
TIMER
SUPPLY
LOAD LOAD
LOAD
H
Typical Wiring Diagram, 208-240 VAC Application
Typica
l
Wiring Diagram, 120
/
277VAC App
l
ication
DTWH40
N
LN
NC NO C
LN
NC NO C
LN
Typical Wiring Diagram, 120 VAC Application
HN
L1 L2
NC NO C
L1
NC NO C
L2
TIMER
SUPPLY
TIMER
SUPPLY
LOAD LOAD
LOAD
H
Typical Wiring Diagram, 208-240 VAC Application
Typica
l
Wiring Diagram, 120
/
277VAC App
l
ication
DTU40
Typical Wiring Diagram, 240VAC
Typical Wiring Diagram, 120VAC
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, a TORK time switch with 24 hour dial. The Time switch input shall be multi-voltage input 120/208/240/277VAC. Time Switch
contacts shall be capable of switching 40 amperes per pole continuously up to 277 volts, and shall be DPDT, covering SPST, SPDT and DPST applications as
required. Captive ON/OFF trippers shall accomplish 1-48 operation per day. 96 trippers permits 15 minutes switching changes. Enclosure shall be Heavy duty
lockable plastic Indoor/Outdoor NEMA 3R surface type, finished in beige, with combination
1
2
”,
3
4
” knockouts on bottom sides and back. Provisions shall be
made for positive padlocking. Terminal shall be capable of receiving #8-#18 AWG wire. The Time Switch shall be TORK Model TU40_.
APPLICATIONS
ORDERING INFO
FEATURES
1100 SERIES
SAME DAY ON/OFF
TIMES EACH DAY
24 HOUR TIME SWITCH
Lighting
Pumps
Signs
Air conditioning
Water heaters
Fans
Automatic ON/OFF control
when operation is required at
the same time every day.
SCHEDULING: Minimum ON is setting 20
minutes with a minimum OFF setting of 75
minutes. Dial accommodates up to 12 pairs of
trippers. One pair included.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF automatic
operation then resumes.
TORK 31
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
ELECTROMECHANICAL
CONTROLS
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz OUTPUT
CONTACTS ENCLOSURE
TYPE
1101 10011 120 SPST Metal Indoor
NEMA 1
1101-N 10040 120 SPST Noryl® Indoor/Outdoor
NEMA 3R
1101-NC 10053 120 SPST Noryl® Indoor/Outdoor
w/ clear Lexan® cover
1101-O 10015 120 SPST Metal Indoor/Outdoor
NEMA 3
1101-M 10022 120 SPST Mechanism
1101-M-IAP 10052 120 SPST Mechanism and
mounting plate
1101-7 10033 347 SPST Metal Indoor
NEMA 1
1102 10012 208-277 SPST Metal Indoor
NEMA 1
1102-N 10045 208-277 SPST Noryl® Indoor/Outdoor
NEMA 3R
1102-O 10046 208-277 SPST Metal Indoor/Outdoor
NEMA 3
1102-M 10035 208-277 SPST Mechanism
1103 10013 120 DPST Metal Indoor
NEMA 1
1103-N 10041 120 DPST Noryl® Indoor/Outdoor
NEMA 3R
1103-NC 10054 120 DPST Noryl® Indoor/Outdoor
w/ clear Lexan® cover
1103-O 10016 120 DPST Metal Indoor/Outdoor
NEMA 3
1103-M 10023 120 DPST Mechanism
1104 10014 208-277 DPST Metal Indoor
NEMA 1
1104-N 10042 208-277 DPST Noryl® Indoor/Outdoor
NEMA 3R
1104-NC 10055 208-277 DPST Noryl® Indoor/Outdoor
w/ clear Lexan® cover
1104-O 10017 208-277 DPST Metal Indoor/Outdoor
NEMA 3
1104-M 10014 208-277 DPST Mechanism
1104-M-IAP 10051 208-277 DPST Mechanism
and mounting plate
Replacement
Trippers Order #P47 for a pair of ON/OFF trippers
Replacement
Motor #101 (120V) & #201 (208-277V)
For Astronomic Conversion: Order #Z KIT
TORK 32
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
INPUT VOLTAGE: 120 or 208-277 VAC
60 Hz, varies by model.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14 AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
POWER CONSUMPTION:
3 watts maximum.
ENCLOSURE: Lockable hasp. Type varies
by model (see page 153 for enclosure
dimensions).
OTHER MOUNTINGS:
Intermatic® Adaptor Plate model #IAP allows
any 1100 series to fit into an Intermatic case.
TYPE VOLTAGE CONTACT
RATING
General Purpose 120 -277VAC
single phase 40A
Resistive 120 -277VAC
single phase 40A
Tungsten 120VAC 40A
Inductive 120, 277VAC
single phase 20A
Pilot Duty 120 -277VAC 1000VA
Motor 120VAC 2HP
240VAC 5HP
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, a TORK time switch with 24 hour dial. The time switch shall be powered by a self-starting synchronous motor. Time switch
contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST as required). Removable ON/OFF trippers shall
make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 75 minutes between one OFF period and the next. Enclosure
shall be NEMA 1 surface type, finished in beige enamel, with combination
1
2
”,
3
4
” knockouts on bottom, both sides and back. Provision shall be made for
positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time switch shall be TORK Model 11_ _ (11_ _–_, etc, to fit requirement).
1101
1102 1103
1104
MANUAL
OFF
LEVER
MANUAL
ON
LEVER
1101 1102
1103
1104
MANUAL
OFF
LEVER
MANUAL
ON
LEVER
Model 1101-7 is 30 AMP inductive at 347 volts and CSA only.
1101 1102 1103
1104
MANUAL
OFF
LEVER
MANUAL
ON
LEVER
1101 1102 1103
1104
MANUAL
OFF
LEVER
MANUAL
ON
LEVER
1101
1102
1103
1104
MANUAL
OFF
LEVER
MANUAL
ON
LEVER
1101 1102 1103
1104
MANUAL
OFF
LEVER
MANUAL
ON
LEVER
1101 1102 1103
1104
MANUAL
OFF
LEVER
MANUAL
ON
LEVER
1101 1102 1103
1104
MANUAL
OFF
LEVER
MANUAL
ON
LEVER
CALIFORNIA Title 24
ASHRAE 90.1
TORK 33
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
ELECTROMECHANICAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
7000 SERIES
WITH SKIP-A-DAY FEATURE
RESERVE POWER OPTIONAL
24 HOUR TIME SWITCH
Lighting
Heating
Pumps
Air conditioning
Signs
Automatic ON/OFF control
when operation is required at
the same time every day, with
optional versatility of one to six
days omission.
SCHEDULING: Minimum ON setting is
20 minutes with minimum OFF setting at
75 minutes. Dial accommodates up to 12
pairs of trippers. One pair included.
SKIP-A-DAY: Omit operations on any
day with a 7-spoke wheel marked with
days of week. 3 omitting screws included.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
OPTIONAL RESERVE POWER: “L”
models keep dial on time up to 16 hours
during power outage.
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz OUTPUT
CONTACTS ENCLOSURE
TYPE
7100 10001 120 SPST Metal Indoor
NEMA 1
7102 10002 208-277 SPST Metal Indoor
NEMA 1
7200 11001 120 DPST Metal Indoor
NEMA 1
7200-O 10512 120 DPST Metal Indoor/Outdoor
NEMA 3
7202 11002 208-277 DPST Metal Indoor
NEMA 1
7202-O 10509 208-277 DPST Metal Indoor/Outdoor
NEMA 3
7300 12001 120 3PST Metal Indoor/Outdoor
NEMA 3
7302 12002 208-277 3PST Metal Indoor/Outdoor
NEMA 3
7120 13001 120 SPDT Metal Indoor
NEMA 1
7122 13002 208-277 SPDT Metal Indoor
NEMA 1
7220 14001 120 DPDT Metal Indoor
NEMA 1
7222 14002 208-277 DPDT Metal Indoor
NEMA 1
WITH RESERVE POWER
7200L 19003 120 DPST Metal Indoor
NEMA 1
7202L 19004 208-277 DPST Metal Indoor
NEMA 1
7300L 19005 120 3PST Metal Indoor/Outdoor
NEMA 3
7302L 19006 208-277 3PST Metal Indoor/Outdoor
NEMA 3
7120L 19007 120 SPDT Metal Indoor
NEMA 1
7220L 19009 120 DPDT Metal Indoor
NEMA 1
7222L 19011 208-277 DPDT Metal Indoor
NEMA 1
Replacement
Trippers Order #P49 for a pair of ON/OFF per dial. Additional ON/OFF trippers per
dial order #P47. 3 omitting screws #53005 supplied.
Replacement
Motor #101 (120V) & #201 (208-277V). For "L" models #36 (120V) & #46
(208-277V). For Astronomic Conversion: Order #Z KIT for 7000 Series.
NEW!
NEW!
TORK 34
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
INPUT VOLTAGE: 120 or 208-277 VAC
60 Hz varies by model.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14 AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
POWER CONSUMPTION: 3 watts,
5 watts for “L” models maximum.
ENCLOSURE: Lockable hasp. Type varies
by model (see page 153 for enclosure
dimensions).
OTHER MOUNTINGS:
Intermatic® Adaptor Plate model #IAP
allows any 7100 and 7200 series (except
“L” models) to fit into an Intermatic case.
TYPE VOLTAGE CONTACT
RATING
General Purpose 120 -277VAC
single phase 40A
Resistive 120 -277VAC
single phase 40A
Tungsten 120VAC 40A
Inductive 120, 277VAC
single phase 20A
Pilot Duty 120 -277VAC 1000VA
Motor 120VAC
240VAC
2HP
5HP
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, a TORK time switch with 24 hour dial and day-omitting device. The time switch shall be powered by a self-starting synchronous
motor. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPST, SPDT, as required).
Removable ON/OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 75 minutes between one OFF
period and the next. Enclosure shall be NEMA 1 surface type, finished in beige enamel, with combination
1
2
”,
3
4
” knockouts on bottom, both sides and back.
Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time Switch shall be TORK Model 7_ _ _ (to fit requirement).
FOR RESERVE POWER (MODELS WITH SUFFIX “L”): Spring-driven reserve shall be provided sufficient to operate the time switch contacts at least 16 hours after
power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.
L1X
M
2
3
5
4
6
L
L
L
N
L 2
LOAD LOAD
LOAD LOAD
LOAD LOAD LOAD
LOAD
LOAD
LOAD
M
H
N
7100 SPST 7300 3PST
7120 SPDT 7220 DPDT
L 1 X 2
M
LOAD
A
N
H
LOAD
B
H
N
M
L1X2
L345
N
H
H
N
H
N
H
M
L1X2
H
N
7200 DPST
FOR USE WITH 3 PHASE 4-WIRE
120/208V SYSTEMS.
L1X
M
2
3
5
4
6
L
L
L
N
L 1 X 2
M
LOAD
A
N
H
LOAD
B
H
N
7120Z (SPDT)
7302 3PST
7200Z (DPST)
H
M
L1X2
LOAD LOAD
H
N
LOAD LOAD LOAD
L1X
M
2
3
5
4
6
L
L
L
N
L 2
LOAD LOAD
LOAD LOAD
LOAD LOAD LOAD
LOAD
LOAD
LOAD
M
H
N
7100 SPST 7300 3PST
7120 SPDT 7220 DPDT
L 1 X 2
M
LOAD
A
N
H
LOAD
B
H
N
M
L1X2
L345
N
H
H
N
H
N
H
M
L1X2
H
N
7200 DPST
FOR USE WITH 3 PHASE 4-WIRE
120/208V SYSTEMS.
L1X
M
2
3
5
4
6
L
L
L
N
L 1 X 2
M
LOAD
A
N
H
LOAD
B
H
N
7120Z (SPDT)
7302 3PST
7200Z (DPST)
H
M
L1X2
LOAD LOAD
H
N
LOAD LOAD LOAD
L1X
M
2
3
5
4
6
L
L
L
N
L 2
LOAD LOAD
LOAD LOAD
LOAD LOAD LOAD
LOAD
LOAD
LOAD
M
H
N
7100 SPST 7300 3PST
7120 SPDT 7220 DPDT
L 1 X 2
M
LOAD
A
N
H
LOAD
B
H
N
M
L1X2
L345
N
H
H
N
H
N
H
M
L1X2
H
N
7200 DPST
FOR USE WITH 3 PHASE 4-WIRE
120/208V SYSTEMS.
L1X
M
2
3
5
4
6
L
L
L
N
L 1 X 2
M
LOAD
A
N
H
LOAD
B
H
N
7120Z (SPDT)
7302 3PST
7200Z (DPST)
H
M
L1X2
LOAD LOAD
H
N
LOAD LOAD LOAD
TORK 35
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
ELECTROMECHANICAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
CALIFORNIA Title 24
ASHRAE 90.1
7000Z SERIES
WITH SKIP-A-DAY FEATURE
RESERVE POWER OPTIONAL
ASTRONOMIC TIME SWITCH
Parking lots
Walkways
Outdoor signage
Window displays
Canopy lighting
Landscape lighting
Automatic ON at dusk, OFF
at dawn. Control of outdoor
lighting.
ASTRONOMIC SCHEDULING: Turn
ON at sunset and OFF at sunrise daily.
OFF time can be set from 8:30PM to
2:30AM. Can be individually offset +/- 20
or 40 minutes from both sunset and OFF
times. Available from 18° - 45° northern
latitudes.
SKIP-A-DAY: Omit operations on any
day with a 7 spoke wheel marked with
days of the week. 3 omitting screws
included.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
OPTIONAL RESERVE POWER: “L”
models keep dial on time up to 16 hours
during power outage.
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz OUTPUT
CONTACTS ENCLOSURE
TYPE
7200Z–* ** 120 DPST Noryl® Indoor/Outdoor
NEMA 3R
7202Z–* ** 208-277 DPST Noryl® Indoor/Outdoor
NEMA 3R
7300Z–* ** 120 3PST Metal Indoor/Outdoor
NEMA 3
7302Z–* ** 208-277 3PST Metal Indoor/Outdoor
NEMA 3
7120Z–* ** 120 SPDT Noryl® Indoor/Outdoor
NEMA 3R
WITH RESERVE POWER
7200ZL–* ** 120 DPST Noryl® Indoor/Outdoor
NEMA 3R
7202ZL–* ** 208-277 DPST Noryl® Indoor/Outdoor
NEMA 3R
7300ZL–* ** 120 3PST Metal Indoor/Outdoor
NEMA 3
7302ZL–* ** 208-277 3PST Metal Indoor/Outdoor
NEMA 3
7120ZL–* ** 120 SPDT Noryl® Indoor/Outdoor
NEMA 3R
7122ZL–* ** 208-277 SPDT Noryl® Indoor/Outdoor
NEMA 3R
Replacement
Motor #101 (120V) & #201 (208-277V).
For "L" models #36 (120V) & #46 (208-277V)
*Add degrees latitude to complete number (18, 30, 34, 38, 40, 42, or 45).
**Consult factory for UPC number.
ADJUSTS TO DAILY CHANGES
IN SUNSET TIMES!
TORK 36
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
MAINE
VT
NH
MASS
NEW YORK
PENNSYLVANIA
OHIO
IND
ILLINOIS
KENTUCKY VIRGINIA
NORTH CAROLINATENNESSEE
WEST
VIRGINIA
SOUTH
CAROLINA
GEORGIAALABAMA
MISS
FLORIDA
LOUISIANA
ARKANSAS
OKLAHOMA
MISSOURI
TEXAS
KANSAS
NEW MEXICO
MEXICO
ARIZONA
CALIFORNIA
NEVADA UTAH COLORADO
NEBRASKA
WYOMING
IDAHO
OREGON
SOUTH DAKOTA
IOWA
WISCONSIN
MICHIGAN
MINN
NORTH DAKOTA
MONTANA
WASHINGTON
RHODE ISLAND
CONNECTICUT
NEW JERSEY
MARYLAND
DELAWARE
45°
42°
40°
38°
34°
30°
ASTRONOMIC LATITUDE ZONES
18° HAWAII 18° PUERTO
RICO
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, a TORK time switch with Astronomic dial and day-omitting device powered by a self-starting synchronous motor. Time switch
contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be (DPST, 3PST or SPDT) as required. ON operation shall occur
automatically at sunset (in city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and
OFF shall have a range of adjustability of 20-40 minutes before or after sunset and sunrise. Enclosure shall be: DPST or SPDT is NEMA 3R indoor/outdoor –
Noryl® – 3PST is NEMA 3 metal indoor/outdoor. Terminals shall be of the pressure type, capable of receiving #8 AWG wire. Time switch shall be TORK Model
7_ _ _Z (to fit requirement).
FOR RESERVE POWER (Add Suffix L): Spring driven reserve shall be provided sufficient to operate the time switch contacts for at least 16 hours after power
failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.
FOR USE WITH 3 PHASE 4-WIRE
120/208V SYSTEMS.
L1X
M
2
3
5
4
6
L
L
L
N
L 1 X 2
M
LOAD
A
N
H
LOAD
B
H
N
7120Z (SPDT)7302 3PST
7200Z (DPST)
H
M
L1X2
LOAD LOAD
H
N
LOAD LOAD LOAD
FOR USE WITH 3 PHASE 4-WIRE
120/208V SYSTEMS.
L1X
M
2
3
5
4
6
L
L
L
N
L 1 X 2
M
LOAD
A
N
H
LOAD
B
H
N
7120Z (SPDT)
7302 3PST
7200Z (DPST)
H
M
L1X2
LOAD LOAD
H
N
LOAD LOAD LOAD
FOR USE WITH 3 PHASE 4-WIRE
120/208V SYSTEMS.
L1X
M
2
3
5
4
6
L
L
L
N
L 1 X 2
M
LOAD
A
N
H
LOAD
B
H
N
7120Z (SPDT)
7302 3PST7200Z (DPST)
H
M
L1X2
LOAD LOAD
H
N
LOAD LOAD LOAD
INPUT VOLTAGE: 120 or 208-277 VAC
60 Hz, varies by model.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14 AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
POWER CONSUMPTION: 3 watts,
5 watts for “L” models maximum.
ENCLOSURE: Lockable hasp. Type varies
by model (see page 153 for enclosure
dimensions).
TYPE VOLTAGE CONTACT
RATING
General Purpose 120 -277VAC
single phase 40A
Resistive 120 -277VAC
single phase 40A
Tungsten 120VAC 40A
Inductive 120, 277VAC
single phase 20A
Pilot Duty 120 -277VAC 1000VA
Motor 120VAC
240VAC
2HP
5HP
TORK 37
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
ELECTROMECHANICAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
8000 SERIES
MANY DAILY ON/OFF
OPERATIONS PER DAY
DUTY CYCLE
24 HOUR TIME SWITCH
Duty cycling
Ventilating fans
Pumping
Irrigation
Process control
Laboratory experiments
For one or multiple daily
ON/OFF operations.
SCHEDULING: Minimum ON setting is
15 minutes with minimum OFF setting at
15 minutes. Dial accommodates up to 96
captive tabs.
DUTY CYCLE: Adjustable from
1
2
, 1, 2,
3, 4, 6, 12, and 24 hours.
SKIP-A-DAY: Some models include 7
day or 14 day wheel to omit selected days
of the week.
OPTIONAL RESERVE POWER: “L”
models keep dial on time up to 16 hours
during power outage.
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz OUTPUT
CONTACTS ENCLOSURE
TYPE
8001 70001 120 SPDT Metal Indoor
NEMA 1
8001-N 70025 120 SPDT Noryl® Indoor/Outdoor
NEMA 3R
8001-NC 70009 120 SPDT Noryl® Indoor/Outdoor NEMA
3R w/ clear Lexan® cover
8001-LC/WB 70010 120 SPDT Mechanism and bracket
8001-O 70029 120 SPDT Metal Indoor/Outdoor
NEMA 3
8004 70002 208-277 SPDT Metal Indoor
NEMA 1
8001U 70003 480/120 Trans. SPDT Metal Indoor
NEMA 1
8001U-N 70014 480/120 Trans. SPDT Noryl® Indoor/Outdoor
NEMA 3R
8001U-O 70011 480/120 Trans. SPDT Metal Indoor/Outdoor
NEMA 3
24 HOUR WITH 7 DAY OMIT
8007 70005 120 SPDT Metal Indoor
NEMA 1
8007-O 70012 120 SPDT Metal Indoor/Outdoor
NEMA 3
8008 70006 208-277 SPDT Metal Indoor
NEMA 1
8007U 70008 480/120 Trans. SPDT Metal Indoor
NEMA 1
8007U-0 70028 480/120 Trans. SPDT Metal Indoor/Outdoor
NEMA 3
24 HOUR WITH 7 DAY OMIT & RESERVE POWER
8007L 70015 120 SPDT Metal Indoor
NEMA 1
8008L 70016 208-277 SPDT Metal Indoor
NEMA 1
24 HOUR WITH 14 DAY OMIT
8007V 70007 120 SPDT Metal Indoor
NEMA 1
24 HOUR WITH 14 DAY OMIT & RESERVE POWER
8007VL 70017 120 SPDT Metal Indoor
NEMA 1
Replacement
Motor #101(120V) & #201 (208-277V).
For “L” models #36 (120V) & #46 (208-277V)
NEW!
NEW!
NEW!
NEW!
8001-N
WIRING DIAGRAMS
TORK 38
CONTACT RATINGS
SPECIFICATIONS
INPUT VOLTAGE: 120, 208-277VAC or
480VAC, 60Hz, varies by model.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
POWER CONSUMPTION: 3 watts,
5 watts for “L” models maximum.
ENCLOSURE: Lockable hasp. Type varies
by model (see page 153 for enclosure
dimensions).
OTHER MOUNTINGS: Intermatic®
Adaptor Plate model #IAP allows 8001 &
8004 to fit into an Intermatic case.
TYPE VOLTAGE CONTACT
RATING
Resistive 120 or 240VAC
480VAC
20A
20A
Motor 120VAC 3/4 HP
SPECIFICATION WRITER’S GUIDE
The time switches shall be of duty cycle type, capable of programming at 15 minute intervals of the day. Scheduled tabs shall be captive on the dial, and shall
be easily set by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike.
The unit shall be powered by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism
shall be a self-contained unit rated at not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the field. FOR 8001 ADD:
The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of the
time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork
Model 8007 or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit,
which shall power the clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The
unit shall be furnished with built-in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.
H
120VAC
N
C
2L
NONC
LOAD 2
M
LOAD 1
CLOSED WITH
TAB INWARD
CLOSED WITH
TAB OUTWARD
ALL SPDT
MODELS
TORK 39
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
PHOTOCONTROLS
APPLICATIONS
FEATURES
SPECIFICATIONS
WIRING DIAGRAMS
CONTACT RATINGS
ELECTROMECHANICAL
CONTROLS
TORK 39
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
APPLICATIONS
FEATURES
SPECIFICATIONS
WIRING DIAGRAMS
ORDERING INFO
8000 SERIES
MULTIPLE ON/OFF CYCLES PER DAY
REPEATING VARIABLE CYCLE
TIME SWITCH
Duty cycling
Ventilating fans
Pumping
Irrigation
Process control
Laboratory experiments
For one or many daily ON/OFF
operations.
SCHEDULING: 60 captive tabs per dial
with minimum ON/OFF settings:
– 60 minute dial with 1 minute tabs.
– 30 minute dial with 30 second tabs.
– 12 minute dial with 12 second tabs.
– 6 minute dial with 6 second tabs.
DUTY CYCLE: Settings of
1
60
th of dial
speed.
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz OUTPUT
CONTACTS TYPE
8601 70034 120 SPDT 60 Minute
8301 70033 120 SPDT 30 Minute
8121 70032 120 SPDT 12 Minute
8061 70031 120 SPDT 6 Minute
Replacement
Motor For 8601 #102, for 8301 #108, for 8121 #107, and for 8061 #105.
INPUT VOLTAGE: 120VAC, 60Hz.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
POWER CONSUMPTION:
3 watts maximum.
ENCLOSURE: Indoor NEMA 1 Metal with
lockable hasp (see page 153 for enclosure
dimensions).
TYPE VOLTAGE CONTACT
RATING
Resistive 120 or 240VAC
480VAC
20A
20A
Motor 120VAC 3/4 HP
H
120VAC
N
C
2L
NONC
LOAD 2
M
LOAD 1
CLOSED WITH
TAB INWARD
CLOSED WITH
TAB OUTWARD
ALL SPDT
MODELS
TORK 40
APPLICATIONS
FEATURES
SPECIFICATIONS
WIRING DIAGRAMS
SPECIFICATIONS
WIRING DIAGRAMS
CONTACT RATINGS
SPECIFICATIONS
WIRING DIAGRAMS
APPLICATIONS
FEATURES
SPECIFICATIONS
WIRING DIAGRAMS
ORDERING INFO
WH2
24 HOUR WATER HEATER
TIME SWITCH
Automatic ON/OFF control of
electric water heaters. Schedules
the water heater to turn ON only
when needed, avoiding energy
waste when hot water is not
needed.
SCHEDULING: Minimum ON is setting 20 minutes
with a minimum OFF setting of 75 minutes. Dial
accommodates up to 12 pairs. 3 pairs of trippers
supplied.
EXTERNAL MANUAL OVERRIDE: Until the
next regularly scheduled ON or OFF automatic
operation then resumes.
INPUT VOLTAGE: 208 – 250V 60 Hz.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
POWER CONSUMPTION:
3 watts maximum.
ENCLOSURE: Indoor NEMA 1 Metal with
lockable hasp (see page 153 for enclosure
dimensions).
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz OUTPUT
CONTACTS ENCLOSURE
TYPE
WH2 70042 208-250 DPST Metal Indoor
NEMA 1
TYPE VOLTAGE CONTACT
RATING
Resistive 208-277VAC 40 A, 10,000W
Replacement Motor #201 (208-277V)
Replacement Trippers Order #P47 for a pair of ON/OFF trippers
L
H
H
1X
2
LOAD
M
TYPICAL FOR 240
VOLT SUPPLY
TORK 40
SAVE
ENERGY!
Avoid utility peak rates
Turn off when not needed
SAVE
ENERGY!
Avoid utility peak rates
Turn off when not needed
SAVE
ENERGY!
Avoid utility peak rates
Turn off when not needed
TORK 41
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
ELECTROMECHANICAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
CALIFORNIA Title 24
ASHRAE 90.1
1800 SERIES
FOR MECHANICALLY HELD CONTRACTORS
AND LOW VOLTAGE REMOTE CONTROL
MOMENTARY CONTACT
TIME SWITCH
SCHEDULING: Choice of three types.
24 HOUR SKIP-A-DAY: Minimum ON setting
is 20 minutes with minimum OFF setting at 75
minutes. Dial accommodates up to 12 pairs of
trippers. Omit operations on any day with a 7
spoke wheel marked with days of week.
ASTRONOMIC SCHEDULING: Turn ON at sunset
and OFF at sunrise daily. OFF time can be set from
8:30PM to 2:30AM. Can be individually offset +/-
20 or 40 minutes from both sunset and OFF times.
7 DAY SCHEDULING: Minimum ON setting is
1 hour with a minimum OFF setting of 2 hours.
Minimum 8 hours between 2 OFF settings. 7 day
calendar dial will accomodate up to 2 pairs on ON/
OFF trippers per day - 7 pairs are supplied.
MANUAL OVERRIDE: Until the next regularly
scheduled ON or OFF, automatic operation then
resumes.
OPTIONAL RESERVE POWER: “L” models keep
dial on time up to 16 hours during power outage.
Mechanically-held contactors
3-wire momentary
lighting systems
Remote station switching
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz OUTPUT
CONTACTS TYPE
1847A 52001 120 SPDT 24 Hour
1848A 52014 208-277 SPDT 24 Hour
1847AZ* ** 120 SPDT Astronomic
1847AW 52005 120 SPDT 7 Day
WITH RESERVE POWER
1847AL 52006 120 SPDT 24 Hour
1847AZL* ** 120 SPDT Astronomic
1847AWL 52010 120 SPDT 7 Day
Replacement
Trippers
For 24 hour models order #P49 for a pair ON/OFF per dial. Additional ON/OFF
trippers per dial order #P47. 3 omitting screws #53005 supplied.
7 day models order #P69 for 7 pairs of ON/OFF trippers.
Replacement
Motor #101(120V) & #201 (208-277V). For “L” models #36 (120V)
*Add degrees latitude to complete number (18, 30, 34, or 42).
**Consult factory for UPC number.
TORK 42
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
INPUT VOLTAGE: 120VAC or 208-277VAC, 60Hz,
varies by model.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #12 - #22AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
POWER CONSUMPTION: 3 watts, 5 watts for
“L” models maximum.
ENCLOSURE: NEMA 1 Metal with lockable hasp
(see page 153 for enclosure dimensions).
TYPE VOLTAGE CONTACT
RATING
General Purpose 24-277VAC 10A
Pilot Duty 24-277VAC 360VA
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, a Momentary Contact time switch. Time switch shall have dial of the (24 hour with day omitting device) (Astronomic with day
omitting device) (7 day calendar) type, which shall be suitable to operate mechanically-held contactor of maximum size. Terminal board shall enable fast and
correct installation using screw terminals for up to #12AWG wire. Timing motor terminals shall be completely independent from momentary switching circuit.
Spring driven reserve mechanism shall be provided sufficient to operate time switch controls at least 16 hours after power failure. On restoration of power, time
switch shall transfer to synchronous motor drive and automatically rewind reserve. Time switch shall include solid state circuit to provide a switch closure not
in excess of two seconds on both ON and OFF contactor coil terminals at such times as are set on dial: these settings to be made with removable trippers which
can be added and removed without tools (except the astronomic dial). Contactor coil circuits shall be suitable for 10 Amp @ 24-277 VAC, 360 VA. Enclosures
shall be NEMA 1 surface (or see other mountings), with provision for positive padlocking. Time switch shall be TORK Model 1847AL, 1848A, (AZL), (AWL).
L
OFFC ON TIMING MOTOR
120VAC, 60HZ
N
CLOSE
OFF
COMMON
OPEN
ON
MOMENTARY PUSH BUTTON
MECHANICALLY-HELD
CONTACTOR
MAINE
VT
NH
MASS
NEW YORK
PENNSYLVANIA
OHIO
IND
ILLINOIS
KENTUCKY VIRGINIA
NORTH CAROLINATENNESSEE
WEST
VIRGINIA
SOUTH
CAROLINA
GEORGIAALABAMA
MISS
FLORIDA
LOUISIANA
ARKANSAS
OKLAHOMA
MISSOURI
TEXAS
KANSAS
NEW MEXICO
MEXICO
ARIZONA
CALIFORNIA
NEVADA UTAH COLORADO
NEBRASKA
WYOMING
IDAHO
OREGON
SOUTH DAKOTA
IOWA
WISCONSIN
MICHIGAN
MINN
NORTH DAKOTA
MONTANA
WASHINGTON
RHODE ISLAND
CONNECTICUT
NEW JERSEY
MARYLAND
DELAWARE
42°
34°
30°
ASTRONOMIC LATITUDE ZONES
18° HAWAII 18° PUERTO
RICO
CALIFORNIA Title 24
ASHRAE 90.1
APPLICATIONS
ORDERING INFO
FEATURES
W SERIES
DIFFERENT SCHEDULES EACH DAY
7 DAY TIME SWITCH
Heating
Air conditioning
Display lighting
Ventilating systems
Lighted signage
Storefront lighting
SCHEDULING: Minimum ON setting is 1 hour
with a minimum OFF setting of 2 hours. Minimum
8 hours between 2 OFF settings. Models W400A
and W402A offer minimum ON/OFF settings of
3
1
2
hours. 7 day calendar dial accommodates up
to 2 pairs of ON/OFF trippers per day – 7 pairs are
supplied.
SKIP-A-DAY: Omit operations on any day.
MANUAL OVERRIDE: Until the next regularly
scheduled ON or OFF automatic operation then
resumes.
OPTIONAL RESERVE POWER: “L” models keep
dial on time up to 24 hours during power outage.
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz OUTPUT
CONTACTS ENCLOSURE
TYPE
W100 30001 120 SPST
Metal Indoor
NEMA 1
W120 33001 120 SPDT
W200 31001 120 DPST
W202 31011 208-277 DPST
W220 34001 120 DPDT
W222 34011 208-277 DPDT
W300 32001 120 3PST
W300-O 32003 120 3PST Metal Indoor/Outdoor
NEMA 3
W302 32002 208-277 3PST
Metal Indoor
NEMA 1
W400A 35001 120 4PST
W402A 35002 208-277 4PST
WITH RESERVE POWER
W220L 39009 120 DPDT
Metal Indoor
NEMA 1
W222L 39010 208-277 DPDT
W300L 39005 120 3PST
W302L 39006 208-277 3PST
W400AL 39007 120 4PST
Replacement
Trippers
Order #P69 for 7 pairs of ON/OFF trippers
except W400 series use #P69i.
Replacement
Motor
#101 (120V) & #201 (208-277V). For W400 series units order #101i
(120V) & #201i (208-277V). For “L” models order #36 (120V)
and #46 (208-277V), except W400 series consult factory.
TORK 43
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
ELECTROMECHANICAL
CONTROLS
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
INPUT VOLTAGE: 120 or 208-277VAC, 60Hz,
varies by model.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
POWER CONSUMPTION: 3 watts, 5 watts for
“L” models maximum.
ENCLOSURE: Indoor NEMA 1 Metal with lockable
hasp. Other enclosures include metal Indoor/
Outdoor NEMA 3 with suffix "O" (see page 153 for
enclosure dimensions).
TORK 44
TYPE VOLTAGE CONTACT
RATING
General Purpose 120 -277VAC
single phase 40A
Resistive 120 -277VAC
single phase 40A
Tungsten 120VAC 40A
Inductive 120, 277VAC
single phase 20A
Pilot Duty 120 -277VAC 1000VA
Motor 120VAC
240 VAC
2HP
5HP
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, TORK time switch of the 7 day type, powered by a self-starting synchronous motor, capable of being set for different ON/
OFF times each day of the week, to an operating accuracy of plus or minus 15 minutes of the desired time. Time switch contacts shall be capable of switching
40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPDT, SPDT, 4PST as required). Removable ON/OFF trippers shall make possible
automatic operation with a minimum ON period of one hour and a minimum of 2 hours between one OFF operation and the next ON. Models W400 and W402
offer minimum ON and OFF settings of 3.5 hours. Enclosure shall be NEMA 1 surface, finished in baked beige enamel, with combination
1
2
” -
3
4
” knock-outs
on bottom and both sides. Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time switch shall be TORK
Model W_ _ _ (to fit requirement). FOR RESERVE POWER (Add suffix L): Spring-driven reserve shall be provided sufficient to operate the Time Switch contacts
at least 24 hours after power failure (16 hour reserve power on 4PST models). On restoration of power, time switch shall transfer to synchronous motor driven
and automatically rewind reserve power unit.
L1X
M
2
3
5
4
6
L
L
L
N
L 2
LOAD
LOAD LOAD
LOAD LOAD LOAD
M
H
N
H
M
L1X2
H
N
L 1 X 2
M
LOAD
ALOAD
LOAD LOAD
LOAD
LOAD
B
N
H
H
N
M
L1X2
L345
N
H
H
N
H
N
M
Clock Motor
Supply
Equipment
Ground
To Load(s)
Supply
A
B
123
56 78
4
W400A (4PST)
W100 (SPST) W200 (DPST) W300 (3PST)W120 (SPDT) W220 (DPDT)
W202 (DPST)
Typical for 208-240VAC
MOTOR
LOAD
H
L1
H
Typical for 277VAC
MOTOR
LOAD
HL1X2
H
LOAD
L1X
M
2
3
5
4
6
L
L
L
N
L 2
LOAD
LOAD LOAD
LOAD LOAD LOAD
M
H
N
H
M
L1X2
H
N
L 1 X 2
M
LOAD
ALOAD
LOAD LOAD
LOAD
LOAD
B
N
H
H
N
M
L1X2
L345
N
H
H
N
H
N
M
Clock Motor
Supply
Equipment
Ground
To Load(s)
Supply
A
B
123
56 78
4
W400A (4PST)
W100 (SPST) W200 (DPST) W300 (3PST)W120 (SPDT) W220 (DPDT)
W202 (DPST)
Typical for 208-240VAC
MOTOR
LOAD
H
L1
H
Typical for 277VAC
MOTOR
LOAD
HL1X2
H
LOAD
CALIFORNIA Title 24
ASHRAE 90.1
TORK 45
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
ELECTROMECHANICAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
T900 SERIES
PHOTOELECTRIC & 7 DAY CONTROL COMBO
DIFFERENT SCHEDULES EACH DAY
RESERVE POWER STANDARD
2 & 3 CIRCUIT LIGHTING
CONTROL CENTERS
Parking lot lighting
HVAC
Display lighting
Security lighting
Lighted signage
Storefront lighting
SCHEDULING:
CIRCUIT 1: ON automatically at dusk, OFF at
individual preset times each day, including
skipping days when desired. Unit can be set to
turn ON before dawn for early morning lighting.
CIRCUIT 2: ON at dusk, OFF at dawn
automatically, daily.
CIRCUIT 3: Individual daily ON and OFF settings
at desired times, including skipping any desired
day or days Minimum ON is setting 1 hour with
a minimum OFF setting of 2 hours. Minimum 8
hours between 2 OFF settings. 7 day calendar dial
will accommodate up to 2 pairs of ON-OFF trippers
per day – 7 pairs are supplied.
SKIP-A-DAY: Omit operations on any day.
MANUAL BY-PASS SWITCHES: Single pole,
20 Amps – one per circuit. Factory pre-wired to
terminal strip. ON/OFF/AUTO positions for each
circuit is independent – will not disturb automatic
settings.
RESERVE POWER: Standard feature on all
models keep dial on time up to 24 hours during
power outage.
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz OUTPUT
CONTACTS ENCLOSURE
TYPE
T920L 41033 120 2 SPDT Metal Indoor
NEMA 1
T920L-E 41034 120 2 SPDT Metal Indoor NEMA
1 with switch access
T920L-O 41035 120 2 SPDT Metal Indoor/outdoor
NEMA 3
T930L 41055 120 3 SPDT Metal Indoor
NEMA 1
T930L-E 41056 120 3 SPDT Metal Indoor NEMA
1 with switch access
T930L-O 41057 120 3 SPDT Metal Indoor/outdoor
NEMA 3
Replacement
Trippers #P69 for 7 pairs of ON/OFF trippers.
Replacement
Motor #36 (120V)
Replacement
Bypass Switch #66061
Optional "E" cover
Model 2101
supplied with unit.
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.
TORK 46
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
INPUT VOLTAGE: 120 or 208-277VAC, 60 Hz,
varies by model.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
POWER CONSUMPTION: 5 watts maximum.
ENCLOSURE: Indoor NEMA 1 Metal with
lockable hasp. Other enclosures include cover
for access to by-pass switches with suffix "E" or
Indoor/Outdoor NEMA 3 metal with suffix "O"
(see page 153 for enclosure dimensions).
TYPE VOLTAGE CONTACT
RATING
General Purpose 120/277VAC 20A
Motor 120VAC
240VAC
1HP
2HP
T920L
T930L
MANUAL CONTROLS
NOTE:
Contacts 7-12
are unpowered.
ON OFF
AUTO
2
345678
ON OFF
AUTO
10 11 12
9
CLOSE
L1 NEU.
OPEN
CONTACTOR
CONTROL
CIRCUIT
1
DUSK TO DAWN SAFETY LIGHTS
(PHOTOCELL ON - PHOTOCELL OFF)
LOAD
RELAY
BLACK
WHITE
RED
LINE
OPEN
LINE
CLOSE
120V
60C
LINE
HN
TIME SWITCH
ONLY CIRCUITS 1 AND 2 ARE INCLUDED IN T920L
M
OFFON
21
C
PHOTOELECTRIC
CONTROL
2
TIME
SWITCH
MANUAL CONTROLS
NOTE:
Contacts 4-12
are unpowered.
M
ON OFF
AUTO
ON OFF
AUTO
2
345678
C
ON OFF
AUTO
10 11 12
9
CLOSE
L1 NEU
OPEN
CONTACTOR
CONTROL
CIRCUIT
OPEN LINE
CLOSE
OPEN LINE
120V
60C
LINE 1
3
DUSK TO DAWN SAFETY LIGHTS
(PHOTOCELL ON - PHOTOCELL OFF)
LOAD
RELAY
BLACK
WHITE
RED
CLOSE
HN
PHOTOELECTRIC
CONTROL
ALL 3 CIRCUITS ARE INCLUDED IN T930L
1
T920L
T930L
MANUAL CONTROLS
NOTE:
Contacts 7-12
are unpowered.
ON OFF
AUTO
2
345678
ON OFF
AUTO
10 11 12
9
CLOSE
L1 NEU.
OPEN
CONTACTOR
CONTROL
CIRCUIT
1
DUSK TO DAWN SAFETY LIGHTS
(PHOTOCELL ON - PHOTOCELL OFF)
LOAD
RELAY
BLACK
WHITE
RED
LINE
OPEN
LINE
CLOSE
120V
60C
LINE
HN
TIME SWITCH
ONLY CIRCUITS 1 AND 2 ARE INCLUDED IN T920L
M
OFFON
21
C
PHOTOELECTRIC
CONTROL
2
TIME
SWITCH
MANUAL CONTROLS
NOTE:
Contacts 4-12
are unpowered.
M
ON OFF
AUTO
ON OFF
AUTO
2
345678
C
ON OFF
AUTO
10 11 12
9
CLOSE
L1 NEU
OPEN
CONTACTOR
CONTROL
CIRCUIT
OPEN LINE
CLOSE
OPEN LINE
120V
60C
LINE 1
3
DUSK TO DAWN SAFETY LIGHTS
(PHOTOCELL ON - PHOTOCELL OFF)
LOAD
RELAY
BLACK
WHITE
RED
CLOSE
HN
PHOTOELECTRIC
CONTROL
ALL 3 CIRCUITS ARE INCLUDED IN T930L
1
SPECIFICATION WRITER’S GUIDE
T900 SERIES – Furnish and install, where shown, a TORK Photo/Time Control of the 7 Day Calendar dial type, which shall be suitable to operate mechanically-
held contactor(s). Photo/Time Control shall be pre-wired to a central terminal block which provides connecting terminals for Photocontrol and independent
contactor control circuit(s). Time switch shall function to prevent energization of lighting for preset periods each day. Time switch dial shall permit different
ON/OFF settings for each day of the week, with provision for omitting selected days. Control shall include pre-wired manual switching for each contactor circuit
specified. Enclosure shall be NEMA 1 surface. Photocontrol to be remotely installed in appropriate outside location. It shall be fully temperature compensated
and shall provide for time delay of at least 15 seconds to prevent false switching. Photocontrol shall operate control center to energize whenever natural lighting
falls below 1.5 - 5.5 foot candles turn on. Spring driven reserve timing motor shall be provided sufficient to operate time switch controls at least 24 hours after
power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit. FOR DUSK-TO-DAWN
LIGHTS: Control shall provide additional contactor circuit to above specifications except that it shall be responsive to Photocontrol only. Tork Model T-920L or
equal. FOR PRESET ON/PRESET OFF: Control shall provide for additional contactor circuit to above specification except that it shall be responsive to time switch
only. Tork Model T-930L.
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.
CALIFORNIA Title 24
ASHRAE 90.1
TORK 47
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
ELECTROMECHANICAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
TW SERIES
DIFFERENT SCHEDULES EACH DAY
MANUAL BYPASS SWITCHES
RESERVE POWER STANDARD
7 DAY TIME SWITCH
Heating
Air conditioning
Display lighting
Ventilating systems
Lighted signage
Storefront lighting
SCHEDULING: Minimum ON setting is 1
hour with a minimum OFF setting of 2 hours.
Minimum 8 hours between 2 OFF settings. 7 day
calendar dial accommodates up to 2 pairs of
ON-OFF trippers per day – 7 pairs are supplied.
SKIP-A-DAY: Omit operations on any day.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
MANUAL BY-PASS SWITCHES: Single pole,
20 Amps – one per circuit. Factory pre-wired
to terminal strip. ON/OFF/AUTO positions for
each circuit is independent – will not disturb
automatic settings.
RESERVE POWER: Standard feature on all
models keep dial on time up to 24 hours during
power outage.
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz OUTPUT
CONTACTS ENCLOSURE
TYPE
TW-220L 39013 120 DPDT Metal Indoor
NEMA 1
TW-220L-E 39021 120 DPDT Metal Indoor NEMA
1 with switch access
TW-222L 39014 208-277 DPDT Metal Indoor
NEMA 1
TW-300L 39015 120 3PST Metal Indoor
NEMA 1
TW-302L 39016 208-277 3PST Metal Indoor
NEMA 1
Replacement
Trippers Order #P69 for 7 pairs of ON/OFF trippers.
Replacement
Motor #36 (120V) & #46 (208-277V)
Replacement
Bypass Switch #66061
Optional "E" cover
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.
TORK 48
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TYPE VOLTAGE CONTACT
RATING
General Purpose 120/277VAC 20A
Motor 120VAC
240VAC
1HP
2HP
ON OFF
AUTO
ON OFF
AUTO
ON OFF
AUTO
M
123456 78 9
LOAD
HN
LINE
TIME
SWITCH
MANUAL CONTROLS
LOAD
LINE
LINE
LOAD
NOTE:
Switching contacts
are unpowered TW300L
TW220L
When single line source is
used, jumper terminals
1-5-7-9 and connect all com-
mons to terminals 2 and 3.
Wiring shown is for mechani-
cally-held contactors. Use
CLOSE terminal only for mag-
netically-held contactors and
to control direct loads not
exceeding 2000 watts.
ON OFF
AUTO
ON OFF
AUTO
M
123456 78 9
OPEN
HN
COMMON
CONTACTOR
CONTROL
CIRCUIT
TIME
SWITCH
MANUAL CONTROLS
CLOSE
COMMON
CLOSE
CONTACTOR
CONTROL
CIRCUIT OPEN
ON OFF
AUTO
ON OFF
AUTO
ON OFF
AUTO
M
123456 78 9
LOAD
HN
LINE
TIME
SWITCH
MANUAL CONTROLS
LOAD
LINE
LINE
LOAD
NOTE:
Switching contacts
are unpowered TW300L
TW220L
When single line source is
used, jumper terminals
1-5-7-9 and connect all com-
mons to terminals 2 and 3.
Wiring shown is for mechani-
cally-held contactors. Use
CLOSE terminal only for mag-
netically-held contactors and
to control direct loads not
exceeding 2000 watts.
ON OFF
AUTO
ON OFF
AUTO
M
123456 78 9
OPEN
HN
COMMON
CONTACTOR
CONTROL
CIRCUIT
TIME
SWITCH
MANUAL CONTROLS
CLOSE
COMMON
CLOSE
CONTACTOR
CONTROL
CIRCUIT OPEN
INPUT VOLTAGE:
120 or 208 - 277VAC, 60Hz, varies by model.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
POWER CONSUMPTION: 5 watts maximum.
ENCLOSURE: Indoor NEMA 1 Metal with lockable
hasp (see page 153 for enclosure dimensions).
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, a TORK time switch of the 7 day type, capable of being set for different ON/OFF times each day of the week, to an operating accuracy
of plus or minus 15 minutes of the desired time. The time switch shall be powered by a self-starting synchronous motor with spring-driven reserve, which shall be
sufficient to operate the time switch contacts at least 24 hours after power outage. On restoration of power, time switch shall transfer to synchronous motor drive and
automatically rewind reserve power unit. Time switch shall provide for automatic operation with a minimum of one hour between an ON/OFF operation with minimum
of four ON/OFF operations per day. ON/OFF operations shall be accomplished by removable ON/OFF trippers on the dial. Time switch contacts shall be capable of
carrying a minimum 20 amperes per pole continuously at 277 volts and shall be DPDT or 3PST. Manual switches shall be provided as an integral part of the time switch,
one for each pole, and shall permit manual switching to maintained ON or OFF positions until manually returned to AUTOMATIC position. Terminal strip shall be capable
of receiving #10AWG wires. Enclosure shall be NEMA 1 surface type, finished in beige enamel, and with
1
2
” -
3
4
” combination knock-outs on bottom, both sides and
top. Provision shall be made for positive padlocking. (Specify “E” door for manual switches to be accessible when case is locked). Shall be TORK Model TW (to fit switch
requirement) or equal in general purpose NEMA 1, (general purpose metal) or (Indoor/Outdoor NEMA 3) enclosure.
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.
TORK 49
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
ELECTROMECHANICAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
CALIFORNIA Title 24
ASHRAE 90.1
TZ SERIES
MANUAL BYPASS SWITCHES
RESERVE POWER STANDARD
ASTRONOMIC TIME SWITCH
Schools
Industrial yards
Shop windows
Parking lots
Highway signs
Bridges
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz OUTPUT
CONTACTS ENCLOSURE
TYPE
TZ-220L* ** 120 DPDT Metal Indoor
NEMA 1
TZ-220L-O* ** 120 DPDT Metal Indoor/outdoor
NEMA 3
TZ-222L* ** 208 - 277 DPDT Metal Indoor
NEMA 1
TZ-300L* ** 120 3PST Metal Indoor
NEMA 1
TZ-300L-O* ** 120 3PST Metal Indoor/outdoor
NEMA 3
TZ-302L* ** 208 - 277 3PST Metal Indoor
NEMA 1
Replacement
Motor For "L" models #36 (120V) & #46 (208-277V)
Replacement
Bypass Switch #66061
*Add degrees latitude to complete number (18, 30, 34, 38, 40, 42, or 45).
**Consult factory for UPC number.
SCHEDULING: Turn ON at sunset and OFF at
sunrise daily. OFF time can be set from 8:30PM
to 2:30AM. Can be individually offset +/- 20
or 40 minutes from both sunset and OFF times.
Available from 18° - 45° northern latitudes.
SKIP-A-DAY: Omit operations on any day with
a 7 spoke wheel marked with days of the week.
3 omitting screws included.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
MANUAL BYPASS SWITCHES: Single pole,
20 Amps - one per circuit. Factory pre-wired to
terminal strip. ON/OFF/AUTO positions for each
circuit is independent, will not disturb automatic
settings.
RESERVE POWER: Standard feature on all
models keep dial on time up to 24 hours during
power outage.
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.
WIRING DIAGRAMS
TORK 50
CONTACT RATINGS
SPECIFICATIONS
INPUT VOLTAGE:
120 or 208 - 277VAC, 60Hz, varies by model.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
POWER CONSUMPTION: 5 watts maximum.
ENCLOSURE: Indoor NEMA 1 Metal with
lockable hasp and for some models enclosures
is Indoor/Outdoor NEMA 3 metal with suffix "O"
(see page 153 for enclosure dimensions).
TYPE VOLTAGE CONTACT
RATING
General Purpose 120/277VAC 20A
Motor 120VAC
240VAC
1HP
2HP
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, a TORK time switch with Astronomic dial and day-omitting device, and a 3-way manual switch for each circuit. The time switch shall
be powered by a self-starting synchronous motor with spring-driven reserve, which shall be sufficient to operate the time switch contacts at least 16 hours after power
failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve. ON operation shall occur automatically at
sunset in (city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of
adjustability of 20 or 40 minutes before or after sunset and sunrise. Time switch contacts shall be capable of carrying a minimum of 20 amperes per pole continuously
at 277 volts and shall be DPST (3PST). Manual switches shall be provided as an integral part of the time switch, one for each pole, and shall permit manual switching
to maintained ON or OFF positions until manually returned to AUTOMATIC position. Terminal strip shall be capable of receiving #10AWG wires. Enclosure shall be NEMA
1 surface type, finished in beige enamel, and with
1
2
” -
3
4
” combination knock-outs on bottom, both sides and top. Provision shall be made for positive padlocking.
(Specify “E” door for manual switches to be accessible when case is locked). Time switch shall be TORK Model TZ-___ (to fit requirement).
MAINE
VT
NH
MASS
NEW YORK
PENNSYLVANIA
OHIO
IND
ILLINOIS
KENTUCKY VIRGINIA
NORTH CAROLINATENNESSEE
WEST
VIRGINIA
SOUTH
CAROLINA
GEORGIAALABAMA
MISS
FLORIDA
LOUISIANA
ARKANSAS
OKLAHOMA
MISSOURI
TEXAS
KANSAS
NEW MEXICO
MEXICO
ARIZONA
CALIFORNIA
NEVADA UTAH COLORADO
NEBRASKA
WYOMING
IDAHO
OREGON
SOUTH DAKOTA
IOWA
WISCONSIN
MICHIGAN
MINN
NORTH DAKOTA
MONTANA
WASHINGTON
RHODE ISLAND
CONNECTICUT
NEW JERSEY
MARYLAND
DELAWARE
45°
42°
40°
38°
34°
30°
ASTRONOMIC LATITUDE ZONES
18° HAWAII 18° PUERTO
RICO
AUTO
M
123456 78 9
LOAD
HN
LINE
TIME
SWITCH
MANUAL CONTROLS
LOAD
LINE
LINE
LOAD
NOTE:
Switching contacts
are unpowered
M
123456 78 9
OPEN
HN
COMMON
CONTACTOR
CONTROL
CIRCUIT
TIME
SWITCH
MANUAL CONTROLS
CLOSE
COMMON
CLOSE
CONTACTOR
CONTROL
CIRCUIT OPEN
TZ300L
TZ220L
When single line
source is used,
jumper terminals
1, 5, 7, 9 and connect
all commons to
terminals 2 and 3.
Wiring shown is for
mechanically held
contactors. Use CLOSE
terminal only for
magnetically held
contactors and to
control direct loads not
exceeding 2000 watts.
AUTO
M
123456 78 9
LOAD
HN
LINE
TIME
SWITCH
MANUAL CONTROLS
LOAD
LINE
LINE
LOAD
NOTE:
Switching contacts
are unpowered
M
123456 78 9
OPEN
HN
COMMON
CONTACTOR
CONTROL
CIRCUIT
TIME
SWITCH
MANUAL CONTROLS
CLOSE
COMMON
CLOSE
CONTACTOR
CONTROL
CIRCUIT OPEN
TZ300L
TZ220L
When single line
source is used,
jumper terminals
1, 5, 7, 9 and connect
all commons to
terminals 2 and 3.
Wiring shown is for
mechanically held
contactors. Use CLOSE
terminal only for
magnetically held
contactors and to
control direct loads not
exceeding 2000 watts.
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.
DIGITAL
TIME SWITCHES
FEATURES
QUICK LOOK
DTU40 DTWH40 E-PB E EW EWZ DG DGM DZS DTS DWZ
Page No. 55 55 57 57 59 61 63 63 65 67 69
Number of Channels 1 1 1 1 or 2 1 or 2 1 or 2 1 or 2 1 1, 2, or 4 1, 2, or 4 1
ON/OFF Set Points 7 pair (98) 7 pair (98) 20 (140) 20 20 20 56 56 99 99 99
365 Day/7 Day Scheduling 7 day 7 day 24 hour 24 hour 7 day 7 day 7/365 day 7/365 day 7/365 day 7/365 day 7/365 day
Automatic Daylight
Savings Adjustment Manual Manual Yes Yes Yes Yes Yes Yes Yes Yes Yes
Leap Year Yes Yes Yes Yes Yes Yes Yes Yes Yes
Individual Holiday Schedules 24 24 24
Block Holiday 9 9
Season Scheduling 4 4
Astronomic (Sunrise/Sunset) Yes Yes Yes
Photosensor Input
Remote Override Input
User Defined Input
Signal/Pulse Duration Yes Yes
Momentary for Contactors Option Option Option Yes
Duty Cycle
31 Day Cycle
Manual Override Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Clock Format AM/PM AM/PM AM/PM AM/PM AM/PM AM/PM 12/24 12/24 12/24 12/24 12/24
Power Outage Backup Rechargeable
Battery
Rechargeable
Battery
4 day Super
Capacitor
4 day Super
Capacitor
4 day Super
Capacitor
4 day Super
Capacitor
7 day Super
Capacitor
7 day Super
Capacitor
7 day Super
Capacitor
7 day Super
Capacitor
7 day Super
Capacitor
Schedule Retention
without power Battery Battery Permanent Permanent Permanent Permanent Permanent Permanent Permanent Permanent Permanent
Staggered Start Yes Yes Yes Yes Yes Yes Yes Yes
Memory Module Yes
Computer Programming
Software Yes
Output Contacts: Amps
Resistive or General Purpose 40A 40A 30A 40A 40A 40A 20A 20A 30A/20A 30A/20A 30A
Contact Type: Dry Unpowered Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Voltage Input AC 120/208-
240/277
120/208-
240/277 120 120-277 120-277 120-277 120-277 120-277 120/208-
240/277
120/208-
240/277
120/208-
240/277
Low Voltage Input
(select models) 12VDC 24VAC
TORK
53
ENERGY/LIGHTING
CONTROLS LIGHTING CONTROLS CYCLE - SIGNAL TIMER
DW DZM ELC71/72 ELC74/78/712 DGU DGUM DGLC DLC400 DG DGS DIN
Page No. 69 71 73 75 79 79 79 81 85 85 89
Number of Channels 2 2 1 or 2 4, 8, or 12 1 1 1 or 2 4 1 or 2 1 1 or 2
ON/OFF Set Points 99 99 128 128 56 56 56 99 56 56 8 pair
3 pair/ch
365 Day/7 Day Scheduling 7/365 day 7/365 day 7/365 day 7/365 day 7/365 day 7/365 day 7/365 day 7/365 day 24 Hour 7 Day 7 Day
Automatic Daylight
Savings Adjustment Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Leap Year Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Individual Holiday Schedules 24 24 26 26 24
Block Holiday 10 10 9 9 9
Season Scheduling 4 4
Astronomic (Sunrise/Sunset) Yes Yes Yes Yes
Photosensor Input Yes Yes Yes Yes Yes Yes
Remote Override Input Yes Yes Yes Yes Yes Yes
User Defined Input Yes Yes
Signal/Pulse Duration Yes Yes Yes Yes
Momentary for Contactors Yes Yes Yes Yes
Duty Cycle Yes Yes Yes Yes
31 Day Cycle Yes
Manual Override Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Clock Format 12/24 12/24 12/24 12/24 12/24 12/24 12/24 12/24 12/24 12/24 AM/PM
Power Outage Backup 7 day Super
Capacitor
7 day Super
Capacitor
7 day Super
Capacitor
2 day Capacitor
1 year battery
7 day Super
Capacitor
7 day Super
Capacitor
7 day Super
Capacitor
6 month
battery
7 day Super
Capacitor
7 day Super
Capacitor 8 year battery
Schedule Retention
without power Permanent Permanent Capacitor Battery Permanent Permanent Permanent Permanent Permanent Permanent Battery
Staggered Start Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Memory Module Yes Yes
Computer Programming
Software Yes Yes Yes
Output Contacts: Amps
Resistive or General Purpose 30A 30A 20A 20A 20A 20A 20A 30A 20A 20A 16A
Contact Type: Dry
Unpowered Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Voltage Input AC 120/208-
240/277
120/208-
240/277
120/208-240/
277
24/120/208
240/ 277 120-277 120-277 120-277 120/208-
240/277 120-277 120-277 120
Low Voltage Input
(select models) 24VAC All Models 12VDC
24VAC 24VAC
TORK
54
TORK 55
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
DT SERIES
AUTOMATIC VOLTAGE DETECTION
24 HOUR OR 7 DAY HOUR
TIME SWITCH
DTU40
Pumps, motors, fans
Signs and lighting
Water heaters
Heating and air conditioning
DTWH40
Water Heaters
This timer turns OFF when rates
are high and turns OFF when no
one is home.
DTU40
SCHEDULING: 7 ON & OFF pairs of set points
for individual programs on each day of the
week. Minimum setting is 1 minute.
DAYLIGHT SAVING: Manual button push for
one hour adjustment.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
EXTERNAL MANUAL OVERRIDE: DTWH40
only on clear door. Override without opening
case.
RANDOM MODE: Varies ON and OFF times to
create "lived-in" look when away.
CLOCK FORMAT: AM/PM.
POWER OUTAGE BACKUP: Battery retains
time and schedule.
CATALOG
NO. UPC
CODE TIMER SUPPLY
(VAC) 60Hz NO. OF
CHANNELS DRY CONTACTS
(UNPOWERED)
DTU40 24004 120/208-240/277 1 DPDT
DTWH40 24005 120/240 1 DPDT
NEW!
MORE WIRING
SPACE!
DTWH40
NEW!
SAVE
ENERGY!
Avoid utility peak rates
Turn off when not needed
SAVE
ENERGY!
Avoid utility peak rates
Turn off when not needed
SAVE
ENERGY!
Avoid utility peak rates
Turn off when not needed
WIRING DIAGRAMS
TORK 56
CONTACT RATINGS
SPECIFICATIONS
TORK 56
INPUT VOLTAGE: 120/208-240/277
VAC, 50/60 Hz (auto detection). DTWH40 is
120/240VAC (auto detection).
TERMINAL RANGE: #8 - #18AWG.
OPERATING TEMPERATURE:
-31°F to 116°F (-35°C to +47°C).
POWER CONSUMPTION: 6VA Max.
ENCLOSURE: DTU40 polycarbonate Indoor/
Outdoor NEMA 3R. DTWH40 polycarbonate
indoor NEMA 1 enclosure with clear cover. Both
with lockable hasp (see page 153 for enclosure
dimensions).
TYPE VOLTAGE RATING
NO NC
Resistive 120-277VAC 40A 30A
Inductive 120-277VAC 30A 15A
Ballast 120VAC 30A 10A
277VAC 20A 10A
Tungsten 120VAC 15A
Motor 120VAC
240VAC
1HP/30FLA/90LRA
2HP/20FLA/60LRA
1
4
HP/12FLA/30LRA
1
2
HP/12FLA/33LRA
Pilot duty 120VAC 720VA 290VA
240VAC 720VA 260VA
Resistive 28VDC 20A
Max above 104° 120-277VAC 30A
N
LN
NC NO C
LN
NC NO C
LN
Typical Wiring Diagram, 120 VAC Application
HN
L1 L2
NC NO C
L1
NC NO C
L2
TIMER
SUPPLY
TIMER
SUPPLY
LOAD LOAD
LOAD
H
Typical Wiring Diagram, 208-240 VAC Application
Typica
l
Wiring Diagram, 120
/
277VAC App
l
ication
DTWH40
N
LN
NC NO C
LN
NC NO C
LN
Typical Wiring Diagram, 120 VAC Application
HN
L1 L2
NC NO C
L1
NC NO C
L2
TIMER
SUPPLY
TIMER
SUPPLY
LOAD LOAD
LOAD
H
Typical Wiring Diagram, 208-240 VAC Application
Typica
l
Wiring Diagram, 120
/
277VAC App
l
ication
DTU40
Typical Wiring Diagram, 240VAC
Typical Wiring Diagram, 120VAC
N
LN
NC NO C
LN
NC NO C
LN
Typical Wiring Diagram, 120 VAC Application
HN
L1 L2
NC NO C
L1
NC NO C
L2
TIMER
SUPPLY
TIMER
SUPPLY
LOAD LOAD
LOAD
H
Typical Wiring Diagram, 208-240 VAC Application
Typica
l
Wiring Diagram, 120
/
277VAC App
l
ication
DTWH40
N
LN
NC NO C
LN
NC NO C
LN
Typical Wiring Diagram, 120 VAC Application
HN
L1 L2
NC NO C
L1
NC NO C
L2
TIMER
SUPPLY
TIMER
SUPPLY
LOAD LOAD
LOAD
H
Typical Wiring Diagram, 208-240 VAC Application
Typica
l
Wiring Diagram, 120
/
277VAC App
l
ication
DTU40
Typical Wiring Diagram, 240VAC
Typical Wiring Diagram, 120VAC
TORK 57
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
E & E-PB SERIES
MULTIPURPOSE CONTROLS
1 OR 2 CHANNEL
24 HOUR TIME SWITCH
Signs
Air conditioning
Lighting
Sump pumps
Ventilating fans
SCHEDULING: 20 ON/OFF set points repeat
each day. Minimum setting 1 minute.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
CLOCK FORMAT: AM/PM.
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides
4 days of real time backup.
MOMENTARY OPTION: For mechanically
held contractors: Model E201B only. Configure
with simple jumper change for single-channel
momentary operation.
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 50/60Hz NO. OF
CHANNELS OUTPUT
DRY CONTACTS
E101B 82401 120-277 1 SPST
E103B 82411 120-277 1 DPST
E120B 82406 120-277 1 SPDT
E201B 82466 120-277 2 SPST
E101PB 82461 120 1 SPST
BACK-UP WITHOUT BATTERY,
ECO FRIENDLY!
WIRING DIAGRAMS
DPST
TIMER
SUPPLY
TIMER
SUPPLY
3
356
SPST
4
LOAD
120/277VAC
120/277VAC
120/277VAC
4
34 5
SPDT
E120B
E201B
E103B
E101B
1 2
NLN
LLN
TIMER
SUPPLY
1 2
1 2
LOAD
N
LN
LOAD LOAD
N N
LOAD
N
TIMER
SUPPLY
120/277VAC
E201B ONLY: UNIT MUST
BE CONFIGURED FOR
MOMENTARY OPTION.
345
CH 1
SPST CH 2
SPST
1 2
LN
LOAD
N
6LOAD
N
3
DPST
4
LOAD
208 OR 240VAC
1 2
L1 L2
TIMER
SUPPLY
65
3
MOMENTARY CONFIGURATION
4
120/277VAC
1 2
LN PULSE ON
CH 1
PULSE OFF
TIMER
SUPPLY
65
L
DPST
TIMER
SUPPLY
TIMER
SUPPLY
3
356
SPST
4
LOAD
120/277VAC
120/277VAC
120/277VAC
4
34 5
SPDT
E120B
E201B
E103B
E101B
1 2
NLN
LLN
TIMER
SUPPLY
12
1 2
LOAD
N
LN
LOAD LOAD
N N
LOAD
N
TIMER
SUPPLY
120/277VAC
E201B ONLY: UNIT MUST
BE CONFIGURED FOR
MOMENTARY OPTION.
345
CH 1
SPST CH 2
SPST
1 2
LN
LOAD
N
6LOAD
N
3
DPST
4
LOAD
208 OR 240VAC
1 2
L1 L2
TIMER
SUPPLY
65
3
MOMENTARY CONFIGURATION
4
120/277VAC
1 2
LN PULSE ON
CH 1
PULSE OFF
TIMER
SUPPLY
65
L
DPST
TIMER
SUPPLY
TIMER
SUPPLY
3
356
SPST
4
LOAD
120/277VAC
120/277VAC
120/277VAC
4
34 5
SPDT
E120B
E201B
E103B
E101B
1 2
NLN
LL
N
TIMER
SUPPLY
1 2
1 2
LOAD
N
LN
LOAD LOAD
N N
LOAD
N
TIMER
SUPPLY
120/277VAC
E201B ONLY: UNIT MUST
BE CONFIGURED FOR
MOMENTARY OPTION.
345
CH 1
SPST CH 2
SPST
1 2
LN
LOAD
N
6LOAD
N
3
DPST
4
LOAD
208 OR 240VAC
1 2
L1 L2
TIMER
SUPPLY
65
3
MOMENTARY CONFIGURATION
4
120/277VAC
1 2
LN PULSE ON
CH 1
PULSE OFF
TIMER
SUPPLY
65
L
DPST TIMER
SUPPLY
TIMER
SUPPLY
3
356
SPST
4
LOAD
120VAC
120VAC 120VAC
434 5
SPDT
E120PB
E103PB
E101PB
1 2
NLN
LLN
TIMER
SUPPLY
1 2 1 2
LOAD
NLN
LOAD LOAD
N N
LOAD
N
TORK 58
CONTACT RATINGS
SPECIFICATIONS
TIMING ACCURACY: Line Frequency.
INPUT VOLTAGE:
E SERIES
120 - 277VAC, 50/60Hz (automatic detection).
E-PB
120VAC, 50/60Hz.
TERMINAL RANGE: #8 - #16AWG.
OPERATING TEMPERATURE:
-40° to +149°F (-40° to +65°C).
POWER CONSUMPTION: 6VA Max.
ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R
is standard with lockable hasp (see page 153 for
enclosure dimensions).
TYPE E101B, E103B, E201B E120B E101PB
VOLTAGE RATING RATING VOLTAGE RATING
NO NO NC NO
General Purpose 120-277VAC 40A 30A 30A 120/240VAC
277VAC
30A
12A
Inductive 120-277VAC 40A 30A 30A 120/240VAC
277VAC
30A
12A
Ballast 120VAC 30A 30A 10A 120VAC 20A
208-277VAC 20A 20A 10A 277VAC 6A
Tungsten 120VAC 15A 15A 2A 120VAC 5A
Pilot Duty 120-277VAC 720VA 720VA 720VA 120-277VAC 470VA
Motor
120VAC 1HP 1HP 1HP 120VAC 1HP
208VAC 1
1
2
HP 1
1
2
HP 1
1
2
HP 240VAC 2HP
240-277VAC 2HP 2HP 2HP
Resistive 28VDC 30A 30A 30A 28VDC 20A
DPST
TIMER
SUPPLY
TIMER
SUPPLY
3
356
SPST
4
LOAD
120/277VAC
120/277VAC
120/277VAC
4
34 5
SPDT
E120B
E201B
E103B
E101B
1 2
NLN
LLN
TIMER
SUPPLY
12
1 2
LOAD
N
LN
LOAD LOAD
N N
LOAD
N
TIMER
SUPPLY
120/277VAC
E201B ONLY: UNIT MUST
BE CONFIGURED FOR
MOMENTARY OPTION.
345
CH 1
SPST CH 2
SPST
1 2
LN
LOAD
N
6LOAD
N
3
DPST
4
LOAD
208 OR 240VAC
1 2
L1 L2
TIMER
SUPPLY
65
3
MOMENTARY CONFIGURATION
4
120/277VAC
1 2
LN PULSE ON
CH 1
PULSE OFF
TIMER
SUPPLY
65
L
SPECIFICATION WRITER’S GUIDE
E100B only – 1. Furnish and install a TORK digital time switch with (40 Amp SPST contacts, model E101B,E201B) (40 Amp DPST contacts, model E103B) (30 Amp SPDT
contacts, model E120B). 2. Unit shall be capable of 20 set points. 3. Unit shall repeat the same schedule each day. 4. (Model E201B ONLY) Unit shall be capable of being
a 2 channel maintained or a 1 channel momentary 5. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 6. Unit shall program in AM/PM
format. 7. Unit shall have LCD display. 8. Unit shall have permanent schedule retention. 9. Unit real time clock shall be retained by super capacitor for 100 hours in a
power failure. 10. Unit shall be capable of manual override ON or OFF either to the next scheduled event or permanently. 11. Unit shall have a NEMA 3R Indoor/Outdoor
plastic enclosure. 12. Unit shall have Load Status indication. 13. Unit shall have Power Failure indication. 14. To order specify TORK Model E101B (E103B) (E120B)
(E201B).
TORK 59
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
EW SERIES
MULTIPURPOSE CONTROL
1 OR 2 CHANNEL
7 DAY TIME SWITCH
Outdoor signs
Lighting security
Heating and air conditioning
SCHEDULING: 20 ON & OFF set points
for individual programs for each day of the
week. Minimum setting is 1 minute.
DAYLIGHT SAVING:
Automatic (can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
CLOCK FORMAT: AM/PM.
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides 4
days of real time backup.
MOMENTARY OPTION: For mechanically
held contractors: Model EW201B only. Configure
with simple jumper change for single-channel
momentary operation.
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
AUTOMATIC DST - SAVES TIME
CHANGES TWICE A YEAR
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 50/60Hz NO. OF
CHANNELS OUTPUT
DRY CONTACTS
EW101B 82431 120-277 1 SPST
EW103B 82441 120-277 1 DPST
EW120B 82436 120-277 1 SPDT
EW201B 82467 120-277 2 SPST
EW103B-C 82253 120-277 1 DPST
EW103B-Y 82255 120-277 1 DPST
EW120B-C 82437 120-277 1 SPDT
EW120B-Y 82261 120-277 1 SPDT
EW201B-Y 82299 120-277 2 SPST
TORK 60
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TIMING ACCURACY: Line Frequency.
INPUT VOLTAGE:
120 - 277VAC, 50/60Hz (automatic detection).
TERMINAL RANGE: #8 - #16AWG.
OPERATING TEMPERATURE:
-40° to +149° (-40° to +65°C).
POWER CONSUMPTION: 6VA Max.
ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R.
Suffix -C plastic clear cover Indoor/Outdoor NEMA
3R. Suffix -Y metal Indoor enclosure NEMA 1. All
with lockable hasp (see page 153 for enclosure
dimensions).
TYPE EW101B, EW103B, EW201B EW120B
VOLTAGE RATING VOLTAGE RATING
NO NO NC
General Purpose 120-277VAC 40A 120-277 VAC 30A 30A
Inductive 120-277VAC 40A 120-277 VAC 30A 30A
Ballast 120VAC 30A 120VAC 30A 10A
208-277VAC 20A 208-277VAC 20A 10A
Tungsten 120VAC 15A 120VAC 15A 2A
Pilot Duty 120-277VAC 720VA 120-277 VAC 720VA 720VA
Motor
120VAC 1HP 120VAC 1HP 1HP
208VAC 1
1
2
HP 208VAC 1
1
2
HP 1
1
2
HP
240-277VAC 2HP 240-277VAC 2HP 2HP
Resistive 28VDC 30A 28 VDC 30A 30A
3
SPST
4
LOAD
120/277VAC
EW101B
1 2
NLN
TIMER
SUPPLY
EW201B
momentary configuration
EW201B ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
CH 1
TIMER
SUPPLY
356
120/277VAC
PULSE ON PULSE OFF
4
LN
1 2
CH 1 CH 2
SPST SPST
TIMER
SUPPLY
120/277VAC
34 5
SPDT
EW120B
1 2
LN
LOAD LOAD
N N
DPST
TIMER
SUPPLY
356
120/277VAC
4
LLNNN
LOAD LOAD
LOAD
1 2
EW103B
DPST
TIMER
SUPPLY
356
208 OR 240VAC
4
L1 L2
1 2
3
SPST
4
LOAD
120/277VAC
EW101B
1 2
NLN
TIMER
SUPPLY
EW201B
momentary configuration
EW201B ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
CH 1
TIMER
SUPPLY
356
120/277VAC
PULSE ON PULSE OFF
4
LN
1 2
CH 1 CH 2
SPST SPST
TIMER
SUPPLY
120/277VAC
34 5
SPDT
EW120B
1 2
LN
LOAD LOAD
N N
DPST
TIMER
SUPPLY
356
120/277VAC
4
LLNNN
LOAD LOAD
LOAD
1 2
EW103B
DPST
TIMER
SUPPLY
356
208 OR 240VAC
4
L1 L2
1 2
3
SPST
4
LOAD
120/277VAC
EW101B
1 2
NLN
TIMER
SUPPLY
EW201B
momentary configuration
EW201B ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTAR
Y OPTION
CH 1
TIMER
SUPPLY
356
120/277VAC
PULSE ON PULSE OFF
4
LN
1 2
CH 1 CH 2
SPST SPST
TIMER
SUPPLY
120/277VAC
34 5
SPDT
EW120B
1 2
LN
LOAD LOAD
N N
DPST
TIMER
SUPPLY
356
120/277VAC
4
LLNNN
LOAD LOAD
LOAD
1 2
EW103B
DPST
TIMER
SUPPLY
356
208 OR 240VAC
4
L1 L2
1 2
3
SPST
4
LOAD
120/277VAC
EW101B
1 2
NLN
TIMER
SUPPLY
EW201B
momentary configuration
EW201B ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
CH 1
TIMER
SUPPLY
356
120/277VAC
PULSE ON PULSE OFF
4
LN
1 2
CH 1 CH 2
SPST SPST
TIMER
SUPPLY
120/277VAC
34 5
SPDT
EW120B
1 2
LN
LOAD LOAD
N N
DPST
TIMER
SUPPLY
356
120/277VAC
4
LL
NNN
LOAD LOAD
LOAD
1 2
EW103B
DPST
TIMER
SUPPLY
356
208 OR 240VAC
4
L1 L2
1 2
SPECIFICATION WRITER’S GUIDE
EW SERIES – 1. Furnish and install a TORK digital time switch with (40 Amp SPST contacts, model EW101B, EW210B) (40 Amp DPST contacts, model EW103B) (30 Amp
SPDT contacts, model EW120B). 2. Unit shall be capable of 20 set points. 3. Unit shall be capable of a different schedule each day of the week. 4. (Model EW201B ONLY)
Unit shall be capable of being a 2 channel maintained or a 1 channel momentary. 5. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 6.
Unit shall program in AM/PM format. 7. Unit shall have LCD display. 8. Unit shall have permanent schedule retention. 9. Unit real time clock shall be retained by super
capacitor for 100 hours in a power failure. 10. Unit shall be capable of manual override ON or OFF either to the next scheduled event or permanently. 11. Unit shall have
a NEMA 3R Indoor/Outdoor plastic enclosure. 12. Unit shall have Load Status indication. 13. Unit shall have Power Failure indication. 14. To order specify TORK Model
EW101B (EW103B) (EW120B) (EW201B).
TORK 61
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
EWZ SERIES
MULTIPURPOSE CONTROL
1 OR 2 CHANNEL, ASTRONOMIC
7 DAY TIME SWITCH
Outdoor signs
Lighting security
Heating and air conditioning
SCHEDULING: 20 ON & OFF set points
for individual programs for each day of the
week. Minimum setting is 1 minute.
ASTRONOMIC: Adjustable 10° - 60°
Northern or Southern latitudes. Can be
individually offset +/- 1-240 minutes
from both sunset and sunrise times.
DAYLIGHT SAVING: Automatic
(can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
CLOCK FORMAT: AM/PM.
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides 4 days
of real time backup.
MOMENTARY OPTION: For mechanically held
contactors: Model EWZ201 only. Configure
with simple jumper change for single-channel
momentary operation.
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 50/60Hz NO. OF
CHANNELS OUTPUT
DRY CONTACTS
EWZ101 82470 120-277 1 SPST
EWZ103 82473 120-277 1 DPST
EWZ120 82471 120-277 1 SPDT
EWZ201 82472 120-277 2 SPST
EWZ101-MB 82263 120-277 1 SPST
EWZ103-MB 82269 120-277 1 DPST
EWZ120-MB 82275 120-277 1 SPDT
EWZ201-MB 82281 120-277 2 SPST
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
PREFERRED FOR
OUTDOOR LIGHTING
TORK 62
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TIMING ACCURACY: Line Frequency.
INPUT VOLTAGE:
120 - 277VAC, 50/60Hz (automatic detection).
TERMINAL RANGE: #8 - #16AWG.
OPERATING TEMPERATURE:
-40° to +149° (-40° to +65°C).
POWER CONSUMPTION: 6VA Max.
ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R
is standard with lockable hasp (see page 153 for
enclosure dimensions). Suffix -MB without enclosure
and includes mounting bracket.
TYPE EWZ101,EWZ103, EWZ201 EWZ120
VOLTAGE RATING VOLTAGE RATING
NO NO NC
General Purpose 120-277VAC 40A 120-277 VAC 30A 30A
Inductive 120-277VAC 40A 120-277 VAC 30A 30A
Ballast 120VAC 30A 120VAC 30A 10A
208-277VAC 20A 208-277VAC 20A 10A
Tungsten 120VAC 15A 120VAC 15A 2A
Pilot Duty 120-277VAC 720VA 120-277 VAC 720VA 720VA
Motor
120VAC 1HP 120VAC 1HP 1HP
208VAC 1
1
2
HP 208VAC 1
1
2
HP 1
1
2
HP
240-277VAC 2HP 240-277VAC 2HP 2HP
Resistive 28VDC 30A 28 VDC 30A 30A
3
SPST
4
LOAD
120/277VAC
EWZ101
1 2
NLN
TIMER
SUPPLY
EWZ201
momentary configuration
EWZ201 ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
CH 1
TIMER
SUPPLY
356
120/277VAC
PULSE ON PULSE OFF
4
LN
1 2
CH 1 CH 2
SPST SPST
TIMER
SUPPLY
120/277VAC
34 5
SPDT
EWZ120
1 2
LN
LOAD LOAD
N N
DPST
TIMER
SUPPLY
356
120/277VAC
4
LLNNN
LOAD LOAD
LOAD
1 2
EWZ103
DPST
TIMER
SUPPLY
356
208 OR 240VAC
4
L1 L2
1 2
3
SPST
4
LOAD
120/277VAC
EWZ101
1 2
NLN
TIMER
SUPPLY
EWZ201
momentary configuration
EWZ201 ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
CH 1
TIMER
SUPPLY
356
120/277VAC
PULSE ON PULSE OFF
4
LN
1 2
CH 1 CH 2
SPST SPST
TIMER
SUPPLY
120/277VAC
34 5
SPDT
EWZ120
1 2
LN
LOAD LOAD
N N
DPST
TIMER
SUPPLY
356
120/277VAC
4
LLNNN
LOAD LOAD
LOAD
1 2
EWZ103
DPST
TIMER
SUPPLY
356
208 OR 240VAC
4
L1 L2
1 2
3
SPST
4
LOAD
120/277VAC
EWZ101
1 2
NLN
TIMER
SUPPLY
EWZ201
momentary configuration
EWZ201 ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
CH 1
TIMER
SUPPLY
356
120/277VAC
PULSE ON PULSE OFF
4
LN
1 2
CH 1 CH 2
SPST SPST
TIMER
SUPPLY
120/277VAC
34 5
SPDT
EWZ120
1 2
LN
LOAD LOAD
N N
DPST
TIMER
SUPPLY
356
120/277VAC
4
LLNNN
LOAD LOAD
LOAD
1 2
EWZ103
DPST
TIMER
SUPPLY
356
208 OR 240VAC
4
L1 L2
1 2
3
SPST
4
LOAD
120/277VAC
EWZ101
1 2
NLN
TIMER
SUPPLY
EWZ201
momentary configuration
EWZ201 ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
CH 1
TIMER
SUPPLY
356
120/277VAC
PULSE ON PULSE OFF
4
LN
1 2
CH 1 CH 2
SPST SPST
TIMER
SUPPLY
120/277VAC
34 5
SPDT
EWZ120
1 2
LN
LOAD LOAD
N N
DPST
TIMER
SUPPLY
356
120/277VAC
4
LL
NNN
LOAD LOAD
LOAD
1 2
EWZ103
DPST
TIMER
SUPPLY
356
208 OR 240VAC
4
L1 L2
1 2
SPECIFICATION WRITER’S GUIDE
EWZ SERIES – 1. Furnish and install TORK digital time switch with (40 AMP contacts, models EWZ101, EWZ201) (40 Amp DPST contacts, model EWZ103) (30 AMP
contacts, model EWZ120). 2. Unit shall be capable of 20 set points. 3. Unit shall be capable of a different schedule for each day of the week. 4. Unit shall be have
astronomic option adjustable from 1°- 60° northern or southern latitudes. 5. Unit shall be have astronomic option with offset up to 4 hours and 59 minutes, before or
after sunrise. 6. (Model EWZ201 ONLY) Unit shall be capable of being a 2 channel maintained or a 1 channel momentary. 7. Unit shall have automatic Daylight Savings
Time and Leap Year compensation. 8. Unit shall program in AM/PM format. 9. Display shall be of LCD type. 10. Unit shall have permanent schedule retention. 11. Unit
real time clock shall be retained by capacitor for 100 hours in a power failure. 12. Unit shall be capable of manual override ON or OFF either in the next scheduled event
or permanently. 13. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 14. Unit shall have Load Status indication. 15. Unit shall have Power Failure
indication. 16. To order specify TORK Model EWZ101 (EWZ103) (EWZ120) (EWZ201).
CALIFORNIA Title 24
ASHRAE 90.1
TORK 63
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
DG100 SERIES
MULTIPURPOSE CONTROLS
1 OR 2 CHANNEL
365/7 DAY
TIME SWITCH
Indoor/Outdoor lighting
HVAC equipment
School warning and other
Traffic lights
Water heaters in offices,
churches and factories
SCHEDULING: 56 ON & OFF set points
provide individual programs for each day of
the week. Minimum setting is 1 minute.
MOMENTARY CONTACT: DGM100A has 2
second contact closures for ON & OFF control of
mechanically held contactors or latching relays.
BLOCK HOLIDAY: 9 holiday blocks can be
set for individual days or for duration of any
number of days.
DAYLIGHT SAVING: Automatic
adjustment (can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
CLOCK FORMAT: AM/PM or 24 Hour
format.
POWER OUTAGE BACKUP: Permanent
schedule retention is provided. Supercapacitor
provides 7 days of real time back up.
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 50/60Hz NO. OF
CHANNELS OUTPUT
CONTACTS
DG100A 82201 120-277VAC 1 DPDT
DG200A 82209 120-277VAC 2 SPDT
DGM100A 82210 120-277VAC 1 SPDT
Momentary
DGM100A-Y 82222 120-277VAC 1 SPDT
Momentary
HOLIDAY PROGRAMMING
FOR MORE SAVINGS!
NEW!
SPECIFICATION WRITER’S GUIDE
DG100/200A SERIES – 1. Furnish and install, where noted, a 1 (2) channel 7-day programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or
Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast loads at 277VAC. 4. Controller shall be capable fo 56 set points; separate scheduling for
each day of the week with one minute resolution. 5. Controller shall have 365 day holiday capabilities with 9 block holidays for individual or duration of any number of
days. 6. Controller shall be able to select USA Standard Daylight Saving, Standard time, or programmable dates. 7. Controller shall have automatic Leap Year correction.
8. Controller shall have Permanent Schedule Retention. 9. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 10.
Controller shall be capable of Manual Override ON or OFF to the next scheduled event using 1 button for each channel. 11. Unit shall have NEMA Type 3R indoor/outdoor
enclosure as standard. 12. To order specify TORK Model DG100A (DG200A). 13. To order momentary contact closure for latching contactor control specify DGM100A.
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TIMING ACCURACY: Line Frequency.
INPUT VOLTAGE:
120 - 277VAC, 50/60Hz (automatic detection).
TERMINAL RANGE: #12 - #18AWG.
OPERATING TEMPERATURE:
-31° to +131°F (-35° to +55°C).
POWER CONSUMPTION: 6VA Max.
ENCLOSURE: Noryl® Indoor/Outdoor NEMA
3R. Suffix -Y metal indoor enclosure NEMA 1. All
with lockable hasp (see page 153 for enclosure
dimensions).
TYPE VOLTAGE RATING
NO NC
Resistive 24-277VAC 20A 10A
Ballast 120 VAC
277 VAC 20A 10A
Tungsten 120VAC 15A
Pilot Duty 120VAC
240VAC 720VA 290VA
360VA
Motor 120VAC
240VAC
1HP
2HP
1
4
HP
1
2
HP
Resistive 28VDC 20A 10A
120/277VAC
120/277VAC
120/277VAC
TORK 64
APPLICATIONS
FEATURES
TORK 65
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
ORDERING INFO
DZS SERIES
MULTIPURPOSE CONTROLS
1, 2 OR 4 CHANNEL
365 / 7 DAY ADVANCED
TIME SWITCH
HVAC equipment
Horns and bells
Interior lighting
Electric motors
Outdoor lighting
and signs
SCHEDULING: 99 ON & OFF set points
allow individual programs for each day of
the week at a minimum 1 minute apart.
ASTRONOMIC: Adjustable 10˚ - 60˚ Northern or
Southern latitudes can be individually offset +/-1 to
240 minutes from both sunset and sunrise times.
SEASONS: 1 to 4 with different daily schedules
which can wrap around into the new year.
HOLIDAYS: 1 to 24 individual dates.
SIGNAL/PULSE DURATION: 2 different
settings per channel: 1-99 seconds.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next regularly
scheduled ON or OFF, automatic operation then
resumes. In signal mode, activates pulse.
CLOCK FORMAT: AM/PM or Military time.
POWER OUTAGE BACKUP: Permanent schedule
retention with memory module. Supercapacitor
provides 7 days of real time backup.
MEMORY MODULE: Removable MM can be
programmed at any one location and inserted into
another DZS series unit.
COPY FEATURE: Unit can be configured to copy
program schedule to multiple memory modules.
OPTION: Memory Module Programmer with
software for computer connection programming. Also
allows stand alone battery operation for portable
copy feature.
CATALOG
NO. UPC
CODE TIMER SUPPLY
(VAC) 50/60Hz NO. OF
CHANNELS DRY CONTACTS
(UNPOWERED)
DZS100BP 82182 120/208-240/277 1 DPDT
DZS200BP 82183 120/208-240/277 2 SPDT
DZS400BP 82184 120/208-240/277 4 SPDT
USB-MMP 82196 Memory Module
Programmer Includes software
DZS100BP-0 82215 120/208-240/277 1 DPDT
DZS200BP-0 82227 120/208-240/277 2 SPDT
DZS200BP-12 82228 12VDC 2 SPDT
DZS200BP-24 82229 24VAC 2 SPDT
DZS400BP-0 82230 120/208-240/277 4 SPDT
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
REMOVABLE MEMORY
MODULE FOR COMPUTER
PROGRAMMING!
TORK 66
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE: 120/208-240/277VAC,
50/60Hz.
TERMINAL RANGE:
#14-#16AWG for line input.
#12-#16AWG load outputs.
OPERATING TEMPERATURE:
-40° to +158°F (-40° to 70°C).
POWER CONSUMPTION:
5VA Max: DZS100/200BP.
6VA Max: DZS400BP.
ENCLOSURE: Noryl® Indoor/Outdoor NEMA
3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All
with lockable hasp (see page 153 for enclosure
dimensions).
CH 1
ON
L
C OFF ONC OFF
CH 2
L
MECHANICALLY HELD CONTACTORS
OR LATCHING RELAYS
PULSE
ON
PULSE
ON
PULSE
OFF
PULSE
OFF
NN
TIMER SUPPLY
N 120
120V
208-240V
277V
208-240277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DZM200B
UPPER
BOARD
LOWER
BOARD
N
LOAD
NO
L
CNCNOC NC
NOGNDCNC NO CNC
N
LOAD
N
LOAD
N
LOAD
L
L L
CH 3
SPDT
CH 4
SPDT
CH 1
SPDT
CH 2
SPDT
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DZS400BP
CH 1
SPDT
CH 2
SPDT
N
LOAD
NO
L
CNCNOCNC
N
LOAD
L
DZS200BP
DZS100BP
N
LOAD
NO
L
CNCNOCNC
N
LOAD
L
DPDT
CH 1
ON
L
C OFF ONC OFF
CH 2
L
MECHANICALLY HELD CONTACTORS
OR LATCHING RELAYS
PULSE
ON
PULSE
ON
PULSE
OFF
PULSE
OFF
NN
TIMER SUPPLY
N 120
120V
208-240V
277V
208-240277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DZM200B
UPPER
BOARD
LOWER
BOARD
N
LOAD
NO
L
CNCNOC NC
NOGNDCNC NO CNC
N
LOAD
N
LOAD
N
LOAD
L
L L
CH 3
SPDT
CH 4
SPDT
CH 1
SPDT
CH 2
SPDT
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DZS400BP
CH 1
SPDT
CH 2
SPDT
N
LOAD
NO
L
CNCNOCNC
N
LOAD
L
DZS200BP
DZS100BP
N
LOAD
NO
L
CNCNO
CN
C
N
LOAD
L
DPDT
CH 1
ON
L
C OFF ONC OFF
CH 2
L
MECHANICALLY HELD CONTACTORS
OR LATCHING RELAYS
PULSE
ON
PULSE
ON
PULSE
OFF
PULSE
OFF
NN
TIMER SUPPLY
N 120
120V
208-240V
277V
208-240277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DZM200B
UPPER
BOARD
LOWER
BOARD
N
LOAD
NO
L
CNCNOC NC
NOGNDCNC NO CNC
N
LOAD
N
LOAD
N
LOAD
L
L L
CH 3
SPDT
CH 4
SPDT
CH 1
SPDT
CH 2
SPDT
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DZS400BP
CH 1
SPDT
CH 2
SPDT
N
LOAD
NO
L
CNCNOCNC
N
LOAD
L
DZS200BP
DZS100BP
N
LOAD
NO
L
CNCNOCNC
N
LOAD
L
DPDT
TYPE
DZS100BP, DZS200BP DZS400BP
VOLTAGE RATING VOLTAGE RATING
NO NC NO NC
General Purpose 24-277VAC 30A 30A 24-277VAC 20A 20A
Ballast 120VAC 30A 10A 120-277VAC 13A
277VAC 20A 10A
Tungsten 120-277VAC 15A 2A 120VAC 8A
Motor Load 120VAC 1HP 1HP 120-277VAC 1HP 1HP
208-277VAC 2HP 2HP
Pilot Duty 120-277VAC 720VA 720VA 12-277VAC 720VA 720VA
Resistive 28VDC 30A 30A
SPECIFICATION WRITER’S GUIDE
DZS SERIES – 1. Furnish and install, where noted, a 4 (2) (1) channel digital time switch with portable Memory Module on front panel. 2. Memory Module shall be
capable of being programmed at any one location and inserted into DZS100BP, 200BP, 400BP Series (with memory module socket) in any other remote location.
3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication of Memory Modules or
individualized programs for multiple locations 4. Unit shall have copy feature: Can be configured to copy program schedules from one memory module to another
without use of the optional memory module programmer. 5. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 6. Controller shall program in
one minute resolution. 7. Display shall be of LCD type. 8. Controller shall be capable of 99 set points; separate scheduling for each day of the week. 9. Controller shall
have 365 day holiday capabilities with 24 single dates and 4 seasons of unlimited duration. 10. Different daily schedules shall be programmable within each season.
11. Controller shall have Daylight Saving or Standard time. 12. Controller shall have automatic Leap Year correction. 13. Controller shall have Permanent Schedule
Retention. 14. Controller shall have 7 day backup for real time with built in super capacitor. 15. Controller shall be capable of manual override ON or OFF to the next
Scheduled event using 1 button for each channel. 16. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 17. Controller shall be capable of having
2 different pulse durations 1-99 seconds, user settable and assignable to each channel. 18. Controller shall be capable of having astronomic on one (or all) channels
with 1-240 minutes, plus or minus offset from Sunrise or Sunset. 19. Controller shall be capable of being configured to copy to multiple memory modules. 20. To order
specify TORK Model DZS100BP (DZS200BP) (DZS400BP).
TORK 67
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
DTS SERIES
MULTIPURPOSE CONTROLS
1, 2 OR 4 CHANNEL
365 / 7 DAY ADVANCE
TIME SWITCH
Indoor and outdoor lighting
Heating and air conditioning
Security systems
Horns and bells
Low voltage lighting
Misting and spraying
Roof cooling
Clock correction systems
Process functions
SCHEDULING: 99 ON/OFF set points
allow individual programs for each day
of the week at a minimum 1 minute apart.
SEASONS: 1 to 4 with different daily
schedules which can wrap around into the new
year.
HOLIDAYS: 1 to 24 individual dates.
SIGNAL/PULSE DURATION: 2 different
settings per channel: each 1-99 seconds.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes. In signal mode,
activates pulse.
CLOCK FORMAT: AM/PM or Military time.
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides
7 days of real time back up.
CATALOG
NO. UPC
CODE TIMER SUPPLY
(VAC) 50/60Hz NO. OF
CHANNELS DRY CONTACTS
(UNPOWERED)
DTS100B 82185 120/208-240/277 1 DPDT
DTS200B 82186 120/208-240/277 2 SPDT
DTS400B 82187 120/208-240/277 4 SPDT
CALIFORNIA Title 24
ASHRAE 90.1
MAINTAINED AND
SIGNAL TIMING
TORK 68
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TIMING ACCURACY: Line Frequency.
INPUT VOLTAGE: 120/208-277VAC,
50/60Hz.
TERMINAL RANGE:
#14 - #16AWG for line input.
#12 - #16AWG load outputs.
OPERATING TEMPERATURE:
-40° to +149° (-40° to +65°C).
POWER CONSUMPTION: 6VA Max.
ENCLOSURE: Noryl® Indoor/Outdoor NEMA
3R with lockable hasp (see page 153 for enclosure
dimensions).
TYPE
DTS100B, DTS200B DTS400B
VOLTAGE RATING VOLTAGE RATING
NO NC NO NC
General Purpose 24-277VAC 30A 30A 24-277VAC 20A 20A
Ballast 120VAC 30A 10A 120-277VAC 13A
277VAC 20A 10A
Tungsten 120-277VAC 15A 2A 120VAC 8A
Pilot Duty 120-277VAC 720VA 720VA 12-277VAC 720VA 720VA
Motor Load 120VAC 1HP 1HP 120-277VAC 1HP 1HP
208-277VAC 2HP 2HP
Resistive 28VDC 30A 30A
UPPER
BOARD
LOWER
BOARD
N
LOAD
NO
L
CNCNOC NC
NOGNDCNC NO CNC
N
LOAD
N
LOAD
N
LOAD
L
L L
CH 3
SPDT
CH 4
SPDT
CH 1
SPDT
CH 2
SPDT
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DTS400B
CH 1
SPDT
CH 2
SPDT
N
LOAD
NO
L
CNCNOCNC
N
LOAD
L
DTS200B
DTS100B
N
LOAD
NO
L
CNCNOCNC
N
LOAD
L
DPDT
UPPER
BOARD
LOWER
BOARD
N
LOAD
NO
L
CNCNOC NC
NOGNDCNC NO CNC
N
LOAD
N
LOAD
N
LOAD
L
L L
CH 3
SPDT
CH 4
SPDT
CH 1
SPDT
CH 2
SPDT
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DTS400B
CH 1
SPDT
CH 2
SPDT
N
LOAD
NO
L
CNCNOCNC
N
LOAD
L
DTS200B
DTS100B
N
LOAD
NO
L
CNCNO
CN
C
N
LOAD
L
DPDT
UPPER
BOARD
LOWER
BOARD
N
LOAD
NO
L
CNCNOC NC
NOGNDCNC NO CNC
N
LOAD
N
LOAD
N
LOAD
L
L L
CH 3
SPDT
CH 4
SPDT
CH 1
SPDT
CH 2
SPDT
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DTS400B
CH 1
SPDT
CH 2
SPDT
N
LOAD
NO
L
CNCNO
CN
C
N
LOAD
L
DTS200B
DTS100B
N
LOAD
NO
L
CNCNOCNC
N
LOAD
L
DPDT
SPECIFICATION WRITER’S GUIDE
DTS SERIES – 1. Furnish and install, where noted, a 4 (2) (1) channel digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats.
3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each
day of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates and 4 seasons of unlimited duration. 7. Different daily schedules shall be
programmable within each season. 8. Controller shall have Daylight Saving or Standard time. 9. Controller shall have automatic Leap Year correction. 10. Controller shall
have Permanent Schedule Retention. 11. Controller shall have 7 day backup for real time with built in super capacitor. 12. Controller shall be capable of manual override
ON to activate pulse #1 duration. 13. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure as standard. 14. Controller shall be capable of having two different pulse
durations 1-99 seconds, user settable and assignable to each channel. 15. To order specify TORK Model DTS100B (200B) (400B).
TORK 69
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
DW SERIES
MULTIPURPOSE CONTROLS
365 / 7 DAY ADVANCED
1 OR 2 CHANNEL TIME
SWITCHES
1 CHANNEL
Outdoor lighting
Security lighting
Parking lot lighting
Canopy lighting
2 CHANNEL
HVAC equipment
Interior lighting
Electric motors
Refrigerator defrost control:
condensers, heaters.
SCHEDULING: 99 ON & OFF set points
allow individual programs for each day
of the week at a minimum 1 minute apart.
ASTRONOMIC (DWZ100B only):
Adjustable 10°- 60° Northern or Southern
latitudes. Can be individually offset +/- 1 to 240
minutes from both sunset and sunrise times.
HOLIDAYS: 1 to 24 individual dates.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation
scheduled ON or OFF, automatic operation then
resumes.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
CLOCK FORMAT: AM/PM or Military time.
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides 7
days of real time backup.
CATALOG
NO. UPC
CODE TIMER SUPPLY
(VAC) 50/60Hz NO. OF
CHANNELS DRY CONTACTS
(UNPOWERED)
DWZ100B 82189 120/208-240/277VAC 1 SPDT
DW200B 82190 120/208-240/277VAC 2 SPDT
DW200B-0 82231 120/208-240/277VAC 2 SPDT
SPECIFICATION
FAVORITE!
SPECIFICATION WRITER’S GUIDE
DWZ100B – 1. Furnish and install, where noted, a 1 channel digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats.
3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each day
of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates. 7. Controller shall have Daylight Saving or Standard time. 8. Controller shall have
automatic Leap Year correction. 9. Controller shall have Permanent Schedule Retention. 10. Controller shall have 7 day backup for real time with built in supercapacitor.
11. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button. 12. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure
as standard. 13. Controller shall be capable of having astronomic with 1-240 minutes, plus or minus offset from sunrise or sunset. 14. To order specify TORK Model
DWZ100B.
DW200B – 1. Furnish and install, where noted, a 2 channel digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats.
3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each day
of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates. 7. Controller shall have Daylight Saving or Standard time. 8. Controller shall have
automatic Leap Year correction. 9. Controller shall have Permanent Schedule Retention. 10. Controller shall have 7 day backup for real time with built in supercapacitor.
11. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button. 12. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure.
WIRING DIAGRAMS
TORK 70
CONTACT RATINGS
SPECIFICATIONS
TIMING ACCURACY: Line Frequency.
INPUT VOLTAGE:
120/208-240-277VAC, 50/60Hz.
TERMINAL RANGE:
#14 - #16AWG for line input.
#12 - #16AWG load outputs.
OPERATING TEMPERATURE:
-40° to +158°(-40° to 70°C).
POWER CONSUMPTION: 5VA Max.
ENCLOSURE: Noryl® Indoor/Outdoor
NEMA 3R. Suffix -0 metal Indoor/Outdoor NEMA
3. All with lockable hasp (see page 153 for
enclosure dimensions).
TYPE VOLTAGE RATING
NO NC
General Purpose 24-277VAC 30A 30A
Ballast 120VAC
277VAC
30A
20A
10A
10A
Tungsten 120-277VAC 15A 2A
Pilot Duty 120-277VAC 720VA 720VA
Motor Load 120VAC
208-277VAC
1HP
2HP
1HP
2HP
Resistive 28VDC 30A 30A
SPDT
N
LOAD
NO
L
CN
C
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
CH 1
SPDT
CH 2
SPDT
N
LOAD
NO
L
CNCNOCNC
N
LOAD
L
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DWZ100B SERIES
DW200B SERIES
TWO SPEED PUMP WIRING
SPDT
N
LOAD
NO
L
CNC
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
A
ND APPLY ONLY ONE VOLTAGE
CH 1
SPDT
CH 2
SPDT
N
LOAD
NO
L
CNCNO
CN
C
N
LOAD
L
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DWZ100B SERIES
DW200B SERIES
TWO SPEED PUMP WIRING
TORK 71
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
TORK 71
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
DZM SERIES
MOMENTARY OUTPUT
365 / 7 DAY ADVANCED
LIGHTING CONTROL TIME
SWITCH
Low voltage latching relays
Direct wire to mechanically
held contactors
SCHEDULING: 99 ON & OFF set points
allow individual programs for each day
of the week at a minimum 1 minute apart.
ASTRONOMIC: Adjustable 10° - 60° Northern
or Southern latitudes can be individually offset
+/- 1 to 240 minutes from both sunset and
sunrise times.
SEASONS: 1 to 4 with different daily
schedules which can wrap around into the new
year.
HOLIDAYS: 1 to 24 individual dates.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
CLOCK FORMAT: AM/PM or Military time.
POWER OUTAGE BACKUP: Permanent
scheduled retention with memory module.
Supercapacitor provides 7 days of real time
backup.
MEMORY MODULE: Removable MM can be
programmed at any one location and inserted
into another DZM series unit.
COPY FEATURE: Unit can be configured to
copy program schedule to multiple memory
modules.
OPTION: Memory Module Programmer with
software for computer connection programming.
Also allows stand alone battery operation for
portable copy feature.
CATALOG
NO. UPC
CODE TIMER SUPPLY
(VAC) 50/60Hz NO. OF
CHANNELS DRY CONTACTS
(UNPOWERED)
DZM200BP 82188 120/208-240/277 2 SPDT
Momentary
DZM200BP-0 82232 120/208-240/277 2 SPDT
Momentary
USB-MMP 82196 Memory Module
Programmer Includes software
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
FEATURES
GREAT FOR LATCHING
CONTACTORS
TORK 72
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TORK 72
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE: 120/208-240/277VAC,
50/60Hz.
TERMINAL RANGE:
#14 - #16AWG for line input.
#12 - #16AWG load outputs.
OPERATING TEMPERATURE:
-40˚ to 158˚F (-40˚ to +70˚C).
POWER CONSUMPTION: 4VA Max.
ENCLOSURE: Noryl® Indoor/Outdoor NEMA
3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All
with lockable hasp (see page 153 for dimensions).
CH 1
ON
L
COFF ON
CO
FF
CH 2
L
MECHANICALLY HELD CONTACTORS
OR LATCHING RELAYS
PULSE
ON
PULSE
ON
PULSE
OFF
PULSE
OFF
NN
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TYPE DZM200BP
VOLTAGE RATING
General Purpose 120-277VAC 20A
Pilot Duty 120-277VAC 720VA
SPECIFICATION WRITER’S GUIDE
DZM 200BP only – 1. Furnish and install, where noted, a 2 channel digital time switch with portable Memory Module on front panel. 2. Memory Module shall be capable
of being programmed at any one location and inserted into DZM200BP (with memory module socket) in any other remote location. 3. Optional programmer shall be
available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication of Memory Modules or individualized programs for multiple
locations 4. Unit shall have copy feature: Can be configured to copy program schedules from one memory module to another without use of the optional memory module
programmer. 5. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 6. Controller shall program in one minute resolution. 7. Display shall be of
LCD type. 8. Controller shall be capable of 99 set points; separate scheduling for each day of the week. 9. Controller shall have 365 day holiday capabilities with 24 single
dates and 4 seasons of unlimited duration. 10. Different daily schedules shall be programmable within each season. 11. Controller shall have Daylight Saving or Standard
time. 12. Controller shall have automatic Leap Year correction. 13. Controller shall have Permanent Schedule Retention. 14. Controller shall have 7 day backup for real
time with built in super capacitor. 15. Controller shall be capable of astronomic function, adjustable from 10 – 60 degrees Northern or Southern latitude. Each zone can
additionally be offset 1 - 240 minutes for both sunset and sunrise. 16. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1
button for each channel. 17. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 18. Controller shall be capable of 2 independent momentary outputs -
ON and OFF for each channel. 19. To order specify TORK Model DZM200BP.
TORK 73
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
ELC SERIES
ENERGY AND LIGHTING CONTROL
1 & 2 ZONE
LIGHTING CONTROL
TIME SWITCH
HVAC equipment
Indoor/Outdoor lighting
Meets indoor/outdoor lighting
energy code requirements
SCHEDULING: 128 time based events allow
individual programs for each day of the week at
a minimum 1 minute apart. Event types include
ON, OFF, Duration, or Duty Cycle.
SENSOR EVENT: 32 sensor driven events
allow individual programs for each day of the
week.
ASTRONOMIC: Adjustable 10° - 70°
Northern or Southern latitudes. Settings can be
offset from both sunset and sunrise times.
UNIVERSAL INPUT: 2 inputs may be assigned
to any channel.
SWITCHED INPUT: Accepts input from optional
momentary or maintained switch.
PHOTOSENSOR INPUT: Accepts input from
optional sensor. EPC-LC (indoor/outdoor) has a
range from 0 to 200 foot-candles.
USER DEFINED INPUT: Accepts user supplied
4 – 20 milliamp sensor.
MOMENTARY CONTACT: May be configured
for momentary ON/OFF operation to control
latching contactors. The ELC71/72 operates as a
single-channel unit.
HOLIDAYS: 26 holidays may be set using 10
individual dates, 10 month type (last Monday
in May), or 6 specific holidays with one of 3
independent holiday schedules.
BLOCK HOLIDAY: 10 holiday blocks can be
set for individual days or for duration of any
number of days and may use one of 3 holiday
schedules.
PULSE/TIME DURATION: 4 different ON
settings from 1 second to 23 hours, 59 minutes,
59 seconds.
DUTY CYCLE: 4 different ON and OFF patterns
from 1 second to 23 hours, 59 minutes, 59
seconds.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation.
REMOTE OVERRIDE: Universal input may
be programmed for timed override from a
momentary or maintained dry contact switch.
MANUAL OVERRIDE: Keyboard button
control until the next regularly scheduled ON or
OFF, automatic operation then resumes.
STAGGERED START: Optional stagger up
time between channels, after a power outage;
selectable from 5 seconds, 15 seconds, 30
seconds, 1 minute, 5 minutes, 10 minutes, and
15 minutes.
CLOCK FORMAT: AM/PM or 24 hour format
POWER OUTAGE BACKUP: Capacitor
provides minimum of 1 week of real time
backup for program and time of day.
CATALOG
NO. UPC
CODE TIMER SUPPLY
(VAC) 50/60Hz NO. OF
CHANNELS OUTPUT
CONTACTS
ELC71PC/120 82517 120 1 DPDT
ELC71PC/208-240 82518 208-240 1 DPDT
ELC71PC/277 82519 277 1 DPDT
ELC72PC/120 82520 120 2 SPDT
ELC72PC/208-240 82521 208-240 2 SPDT
ELC72PC/277 82522 277 2 SPDT
EPC-LC 82233 Accessory Photo
Sensor
LCS115M 82082 Accessory
Momentary Switch SPST
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
THE DO-IT-ALL ENERGY
& LIGHTING CONTROLLER
NEW!
TORK 74
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE:
120, 208-240, 277 50/60Hz (model specific).
TERMINAL RANGE:
#10 - #16AWG for line/load.
#14 - #22AWG universal input.
OPERATING TEMPERATURE:
-20°F to +140°F (-29°C to + 60°C).
POWER CONSUMPTION: 6VA Maximum.
ENCLOSURE: Noryl® clear cover Indoor/
Outdoor NEMA 3R with lockable hasp (see page
153 for enclosure dimensions).
TYPE VOLTAGE RATING
NO NC
General Purpose 120/277VAC 20 A 10 A
Ballast 120VAC
208-277VAC
20A
10A
10A
Tungsten 120-277VAC 5A
Pilot Duty 120-240VAC 470VA 275VA
Motor 120VAC
208-277VAC
1HP
2HP
1
4
HP
1
2
HP
SPECIFICATION WRITER’S GUIDE
Installer shall furnish and install Tork ELC71 single-channel (or ELC72, two-channel) electronic time control. The control shall have 24 hour, 7 day, 365 day, or astronomic
capability with 128 events available. It shall also have 4 user-definable durations and duty cycle lengths plus automatic daylight savings time and leap year adjustments.
Control shall have remote override capabilities (timed, toggle or enable type.) Control shall have keyboard override until overridden again or until next event is reached.
It shall be capable of switching loads based on user-definable temperature and light levels with 32 events available. Control shall have momentary (latching relay)
capability and shall have astronomic features plus 30 definable holidays and 6 pre-programmed holidays. Controller shall have 7 day backup for real time with built in
supercapacitor. The digital time display shall be
3
4
” in height. Clock format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. Wiring terminals
shall have the capability to accommodate #16 to #10 AWG wire. Control shall be housed in NEMA 3R enclosure with clear-view cover and shall be lockable to guard
against vandalism or tampering.
ELC71
ELC72
TORK 75
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
ELC SERIES
ENERGY AND LIGHTING CONTROL
4, 8 & 12 ZONE
LIGHTING CONTROL
TIME SWITCH
HVAC equipment
Indoor/Outdoor lighting
Meets indoor/outdoor lighting
energy code requirements
CATALOG
NO. UPC
CODE TIMER SUPPLY
(VAC) 50/60Hz NO. OF
CHANNELS OUTPUT
CONTACTS
ELC74* 82523 24/120/208-240/277 4 SPDT
ELC78 82524 24/120/208-240/277 8 SPDT
ELC712 82525 24/120/208-240/277 12 SPDT
EPC-LC 82233 Accessory Photo Sensor
LCS115M 82082 Accessory Momentary Switch SPST
SCHEDULING: 128 time based events allow
individual programs for each day of the week at
a minimum 1 minute apart. Event types include
ON, OFF, Duration, or Duty Cycle.
SENSOR EVENT: 32 sensor driven events
allow individual programs for each day of the
week.
ASTRONOMIC: Adjustable 10° - 70°
Northern or Southern latitudes. Settings can be
offset from both sunset and sunrise times.
UNIVERSAL INPUT: 8 inputs may be assigned
to any channel. ELC74 includes 4.
SWITCHED INPUT: Accepts input from optional
momentary or maintained switch.
PHOTOSENSOR INPUT: Accepts input from
optional sensor. EPC-LC (indoor/outdoor) has a
range from 0 - 200 foot-candels.
USER DEFINED INPUT: Accepts user supplied
4 – 20 milliamp sensor.
MOMENTARY CONTACT: May be configured
for momentary ON/OFF operation to control
latching contactors. The ELC74 operates as a
two channel unit. The ELC78 operates as a four
channel unit. The ELC712 operates as a six
channel unit.
HOLIDAYS: 26 holidays may be set using 10
individual dates, 10 month type (last Monday
in May), or 6 specific holidays with one of 3
independent holiday schedules.
BLOCK HOLIDAY: 10 holiday blocks can be
set for individual days or for duration of any
number of days and may use one of 3 holiday
schedules.
PULSE/TIME DURATION: 4 different ON
settings from 1 second to 23 hours, 59 minutes,
59 seconds.
DUTY CYCLE: 4 different ON and OFF patterns
from 1 second to 23 hours, 59 minutes, 59
seconds.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation.
REMOTE OVERRIDE: Universal input may
be programmed for timed override from a
momentary or maintained dry contact switch.
MANUAL OVERRIDE: Keyboard button
control until the next regularly scheduled ON or
OFF, automatic operation then resumes.
STAGGERED START: Optional stagger up
time between channels, after a power outage;
selectable from 5 seconds, 15 seconds, 30
seconds, 1 minute, 5 minutes, 10 minutes, and
15 minutes.
CLOCK FORMAT: AM/PM or 24 hour format.
POWER OUTAGE BACKUP: The program
and time of day are maintained for a minimum
of 2 days by means of a capacitor. After two
days, a lithium battery takes over and provides
a minimum accumulated time of 1 year. The
lithium battery should provide over 10 years of
protection.
COMPUTER INTERFACE: Unit may be
programmed with a PC.
THE DO-IT-ALL ENERGY &
LIGHTING CONTROLLER
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
NEW!
*Also CSA certified.
TORK 76
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE:
24/120/208-240/277VAC, 50/60Hz.
TERMINAL RANGE:
#10 - #16AWG for line input.
#10 - #16AWG for load output.
#14 - #22AWG universal input.
OPERATING TEMPERATURE:
-20°F to +140°F (-29°C to + 60°C).
POWER CONSUMPTION: 10VA Maximum.
ENCLOSURE: Metal Indoor NEMA 1 with
lockable hasp (see page 153 for dimensions).
TYPE VOLTAGE RATING
NO NC
General Purpose 120 - 277VAC 20A 10A
Ballast 120 VAC
208-277 VAC
20A
10A
10A
3A
Tungsten 120-277VAC 5A
Pilot Duty 120-240VAC 470VA 275VA
Motor 120VAC
208-277VAC
1HP
2HP
1
4
HP
1
2
HP
SPECIFICATION WRITER’S GUIDE
Installer shall furnish and install Tork ELC74 four channel (ELC78 eight channel or ELC712 twelve channel) electronic time control. The control shall have 24 hour, 7 day,
365 day or astronomic capability with 128 events available. It shall also have 4 (8) user-definable durations and duty cycle lengths plus automatic daylight saving time
and leap year adjustments. Control shall have remote override capabilities (timed, toggle or enable type). Control shall have keyboard override until overridden again
or until next event is reached. It shall be capable of switching loads based on user-definable temperature and light levels with 32 events available. Control shall have
momentary (latching relay) capability and shall have astronomic features plus 30 definable holidays and 6 pre-programmed holidays. Control shall provide 2 days of
power outage carry-over without a battery. Control shall provide 10 years of power outage protection with a battery. The digital time display shall be
3
4
” in height. Clock
format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. Control shall be capable of interfacing (sending and receiving data) with a personal
computer. Control shall be housed in a NEMA 1, lockable steel enclosure, to guard against vandalism or tampering.
responsible
energy
ASHRAE 90.1
TORK 77
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
LC200 SERIES
LIGHT LEVEL / TIME OF DAY OPTION
2 ZONES LIGHTING CONTROL
TIME SWITCH
24 hour convenience stores
Open wall parking structures
Large canopies
Building perimeters
Atriums
Use to control two different
outdoor lighting circuits utilizing
one photocell. Sign lighting can
turn ON at one ambient light
level while parking lot lighting
turns ON at a different light
level.
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 50/60Hz NO. OF
ZONES OUTPUT
CONTACTS
LC200 82111 120/240/277VAC 2SPDT
LC200M 82113 120/240/277VAC 2SPDT
EPC1 sensor
supplied with unit.
PHOTOSENSOR INPUT: EPC1 included.
DUAL OUTPUTS: with independent turn-ON
adjustment for Stage1 and Stage 2.
LIGHT LEVEL ACTIVATION: Turn ON is user
settable from 2 to 100 footcandle; Independent
light level adjustment for each zone. Turn OFF
is a maximum of 2 times turn ON level. Built-in
delay ON of 30 seconds to avoid reaction to
lightning or headlights.
SWITCHED INPUT: Can be used with a time
switch for photocell ON of two different lighting
circuits at different ambient light levels, then
time-of-day OFF.
STAGE LIGHTING
TURN ON LEVEL
TORK 78
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TYPE VOLTAGE RATING
NO NC
Resistive 120/240VAC
277VAC
20A
12A
10A
Ballast 120VAC
240/277VAC
20A
6A
10A
3A
Tungsten 120/240/277VAC 5A 3A
Pilot Duty 120/240VAC
277VAC
470VA
690VA
275VA
LOAD 1
For 120 VAC
Operation
WHITE
BLACK
POWERSTAGE 1STAGE 2
RUNSET
STAGE 1STAGE 2
LIGHT LEVEL
TOD1
TOD2
C
TOD1
TOD2
C
EPC
110
29
38
47
56
110
29
38
47
56
LOAD 2
EPC1
N
H
NC
LOAD 1
For 240 VAC
Operation
RED
BLACK
H
H
LOAD 2
LOAD 1
For 277 VAC
Operation
WHITE
ORANGE
N
H
LOAD 2
277V
120V240V
NEUT CNC
NO CNC
NO
OUTPUT 2
LINE INPUT OUTPUT 1
277V
120V240V
NEUT CNC
NO CNC
NO
OUTPUT 2
LINE INPUT OUTPUT 1
277V
120V240V
NEUT CNC
NO CNC
NO
OUTPUT 2
LINE INPUT OUTPUT 1
LOAD 1
For 120 VAC
Operation
WHITE
BLACK
POWERSTAGE 1STAGE 2
RUNSET
STAGE 1STAGE 2
LIGHT LEVEL
TOD1
TOD2
C
TOD1
TOD2
C
EPC
110
29
38
47
56
110
29
38
47
56
LOAD 2
EPC1
N
H
NC
LOAD 1
For 240 VAC
Operation
RED
BLACK
H
H
LOAD 2
LOAD 1
For 277 VAC
Operation
WHITE
ORANGE
N
H
LOAD 2
277V
120V240V
NEUT CNC
NO CNC
NO
OUTPUT 2
LINE INPUT OUTPUT 1
277V
120V240V
NEUT CNC
NO CNC
NO
OUTPUT 2
LINE INPUT OUTPUT 1
277V
120V240V
NEUT CNC
NO CNC
NO
OUTPUT 2
LINE INPUT OUTPUT 1
INPUT VOLTAGE:
120/240/277VAC, 50/60Hz.
TERMINAL RANGE: Relay #12AWG; input
power terminals #14 - #22AWG; TOD/sensor
terminals accept #18 - #22AWG.
OPERATING TEMPERATURE:
-40°F to +140°F (-40°C to + 60°C).
POWER CONSUMPTION: 5VA Maximum.
ENCLOSURE: LC200 includes metal Indoor
NEMA 1 with lockable hasp (see page 153 for
dimensions).
OTHER MOUNTINGS:
LC200M mechanism only.
SPECIFICATION WRITER’S GUIDE
Furnish and install an electronic light sensor and control with dual outputs for two lighting zones. Each output shall be capable of a different user settable turn
ON light level set points from 2 to 100 footcandles. Turn ON to turn OFF ratio shall be 1:2. Controller shall also offer two digital inputs, which can accept a contact
closure from an independent time switch or EMS system, thereby allowing for independent time of day control.
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
TORK 79
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
DGU &
DGLC SERIES
LIGHTING CONTROL WITH PHOTO
OR OVERRIDE INPUT, 7 DAY
7 DAY LIGHTING
CONTROL TIME SWITCH
INTERIOR LIGHTING
Open office zoning
Hallways
Meeting and sales areas
Stock rooms and warehouses
EXTERIOR LIGHTING
Signage and store windows
Security
Parking lots
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 50/60 Hz NO. OF
CHANNELS OUTPUT
CONTACTS
DGU100A-Y 82211 120-277VAC 1DPDT
DGUM100A 82212 120-277VAC 1SPDT
Momentary
DGUM100A-Y 82224 120-277VAC 1SPDT
Momentary
DGLC100A-NC 82223 120-277VAC 1DPDT
DGLC200A-NC 82213 120-277VAC 2SPDT
EPC-A 82112 Accessory Photo
Sensor
SSA200R-24 14015 24VAC/24VDC SPDT
TRP-U 82030 120/277VAC Transformer
Power Pack SPST
SCHEDULING: 56 ON & OFF set points
provide individual programs for each day
of the week. Minimum setting is 1 minute.
PHOTOSENSOR INPUT: Unique push
button set-up assures accurate operation
with automatic calibration that adjusts for
wire size and distance. EPC-A photo sensor is
included with the DGLC-A and may be ordered
as an option for use with model DGU100A &
DGUM100A.
LIGHT LEVEL ACTIVATION: Turn ON is user
settable from 1 to 100 footcandle; Turn OFF
is a maximum of 2 times turn ON level. Each
channel has an independent setting. Includes a
user settable delay before ON or OFF between
1 – 90 seconds.
REMOTE OVERRIDE ON: Each channel has
independent input for a maintained dry-contact
closure. May use TORK model SSA200R-24
and TRP-U for timed override. May use with
occupancy sensor as override.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
MOMENTARY CONTACT - DGUM100A:
2 second contact closure ON & OFF to control
mechanically held contactors or latching relays.
BLOCK HOLIDAY: 9 holiday blocks can be
set for individual days or for duration of any
number of days.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation.
CLOCK FORMAT: AM/PM or 24 Hour
format.
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides 7
days of real time backup.
CODE SOLUTION FOR
SMALL PROJECTS
NEW!
With optional
Timed Override
Model EPC-A supplied
with DGLC-A unit.
WIRING DIAGRAMS
TORK 80
CONTACT RATINGS
SPECIFICATIONS
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE: 120-277VAC, 50/60Hz
(auto detection).
TERMINAL RANGE:
#12 - #18AWG for line/load.
#18 - #26AWG sensor/switch input.
OPERATING TEMPERATURE:
-31°F to +131°F (-35°C to + 55°C).
POWER CONSUMPTION: 6VA Maximum.
ENCLOSURE: Noryl® Indoor/Outdoor NEMA
3R . Suffix -NC Noryl® Indoor/Outdoor NEMA
3R with clear Lexan® cover. Suffix -Y metal
Indoor enclosure NEMA 1. All with lockable
hasp (see page 153 for dimensions).
TYPE VOLTAGE RATING
NO NC
Resistive 24-277VAC 20A 10A
Ballast 120VAC
277VAC 20A 10A
Tungsten 120VAC 15A
Pilot Duty 120VAC
240VAC 720VA 290VA
360VA
Motor 120VAC
240VAC
1HP
2HP
1
4
HP
1
2
HP
Resistive 28VDC 20A 10A
SPECIFICATION WRITER’S GUIDE
DGU and DGLC SERIES - 1. Furnish and install, where noted, a 1 (2) channel 7 day programmable digital time switch. 2. Controller shall program in AM/PM (12
hour) or Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast load at 277VAC. 4. Controller shall be capable of 56 set points; separate
scheduling for each day of the week with one minute resolution. 5. Controller shall have photo sensor input user adjustable per circuit between 1 and 100 footcandle
turn ON level. 6. Each channel shall have and switched input to override circuit ON. 7. Controller shall have 365 day holiday capabilities with 9 block holidays
for individual or duration of any number of days. 8. Controller shall be able to select USA Standard Daylight Saving, Standard time, or programmable dates. 9.
Controller shall have automatic Leap Year correction. 10. Controller shall have Permanent Schedule Retention. 11. Controller shall have 7 days backup for real time
with built in super capacitor; no batteries to maintain. 12. Controller shall be capable of Manual Override ON and OFF to the next scheduled event using 1 button
for each channel. 13. Unit shall have NEMA type 3R indoor/outdoor enclosure standard. 14. To order specify TORK Model DGU100A. (Alt 14. To order 1 channel
momentary contact closure for latching contactor control specify DGUM100A). (Alt 14. To order controller with EPC-A photo sensor included in package specify TORK
Model DGLC100A-NC (DGLC200A) with clear cover.
120/277VAC
120/277VAC
120/277VAC
120/277VAC
120/277VAC
120/277VAC
120/277VAC
120/277VAC
120/277VAC
120/277VAC
120/277VAC
120/277VAC
TORK 81
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
DLC400BP
4 ZONE LIGHTING CONTROL
TIME SWITCH
CATALOG
NO. UPC
CODE INPUT SUPPLY (VAC)
50/60 Hz NO. OF
CHANNELS OUTPUT
CONTACTS
DLC400BP 82191 120/208-240/277 4SPDT
USB-MMP 82196 Memory Module
Programmer Includes Software
SSA200R-24 14015 24VAC/24VDC SPDT
CONFIGURABLE ZONES: Simple three
position slide switch sets logic for each zone:
Time ON/Time OFF, Photo ON/Photo OFF, or
Photo ON/ Time OFF.
SCHEDULING: 99 ON & OFF set points allow
individual programs for each day of the week.
Minimum 1 minute apart.
ASTRONOMIC: 1. Adjustable 10° - 60°
Northern or Southern latitudes. 2. Can be
individually offset +/-1-240 minutes from both
sunset and sunrise times.
PHOTOSENSOR INPUT: EPC2 photo sensor
included.
LIGHT LEVEL ACTIVATION: Turn ON
and OFF level is user settable from 1 to 100
footcandle. Each channel has an independent
setting.
REMOTE OVERRIDE: Maintained dry contact
closure or use TORK Model SSA200R-24 for
timed override with flash warning before OFF.
May use with occupancy sensor as override.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
SEASONS: 1 to 4 with different daily schedules
which can wrap around into the new year.
HOLIDAYS: 1 to 24 individual dates.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation.
POWER OUTAGE BACKUP: Permanent
schedule retention with memory module.
Battery provides real time backup for 6 months
cumulative.
MEMORY MODULE: Removable MM can be
programmed at any one location and inserted
into another DZS series unit.
OPTION: Memory Module Programmer with
software for computer connection programming.
Also allows stand alone battery operation for
portable copy feature.
INTERIOR LIGHTING
Open office zoning
Hallways
Meeting and sales areas
Stock rooms and warehouses
EXTERIOR LIGHTING
Signage and store windows
Security
Parking lots
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
Model EPC2
supplied with unit.
Memory Module
Programmer optional
With optional
Timed Override
FLEXIBLE INDOOR/
OUTDOOR LIGHTING
CONTROLLER
TORK 82
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE:
120/208 - 240/277VAC, 50/60Hz.
TERMINAL RANGE: #10 - #14AWG.
OPERATING TEMPERATURE:
-40°F to +158°F (-40°C to + 55°C).
POWER CONSUMPTION: 30VA Maximum.
ENCLOSURE: Metal Indoor/Outdoor NEMA 3 with
lockable hasp (see page 153 for dimensions).
TYPE VOLTAGE RATING
NO NC
General Purpose 24-277VAC, 30VDC 30A 30A
Ballast 120-277VAC 20A 10A
Tungsten 120VAC 10A
Pilot Duty 120-277VAC 720VA 720VA
SPECIFICATION WRITER’S GUIDE
DLC400BP – 1. Furnish and install, where noted, a 4 zone lighting controller with photosensor input (TORK model EPC2 photosensor to be supplied with controller). 2. Memory Module shall be capable of being
programmed at any one location and inserted into DLC400BP (with memory module socket) in any other remote location. 3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows
based settings on a PC for easy duplication of Memory Modules or individualized programs for multiple locations 4. Each zone shall be capable of independent, user settable turn ON and turn OFF light level set
points ranging from 1 to 100 footcandles. 5. Three position slide switches shall be provided for each of the 4 zones allowing for user settings based on a) time of day or b) combination time of day and light level or
c) light level. 6. Controller shall provide 30 Amp General Purpose isolated contacts (unpowered) for each zone as well as a 500 ma, 24VDC output. 7. Controller shall have 1 digital input per channel for: a) remote
contact closure which can be used to turn corresponding outputs ON/OFF outside of the normal control time or b) remote timed override which can be accomplished for the corresponding outputs with the use of TORK
model SSA200R-24. 8. Enclosure shall provide separate wiring compartments for power connections and auxiliary connections. 9. Controller shall be capable of local override ON or OFF to the next scheduled event
using the keypad for each zone. 10. Each zone shall be capable of astronomic function, adjustable from 10 – 60 degrees Northern or Southern latitude. Each zone can additionally be offset +/- 1–299 minutes for
both sunset and sunrise. 11. Controller shall provide automatic daylight saving time (which can be omitted). Leap year adjustment shall be compensated for automatically. 12. Controller shall have 365 day holiday
capability with 24 single dates and 4 seasons of unlimited duration. 13. Controller shall be capable of 99 set points with separate scheduling for each day of the week. 14. Controller shall have back-up capability: a)
Schedule shall be retained for 40 years without power, b) real time shall be retained for 6 months using a field replaceable 9V lithium battery. 15. Unit shall have a NEMA type 3, metal indoor/outdoor enclosure.
ASHRAE 90.1
TORK 83
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
LD SERIES
EXTENDED LIGHTING CONTROL
LIGHTING DELAY
TIME SWITCH
Open offices
Gymnasiums
Warehouses
Outdoor recreation courts
User-activated lights
with time limits
Match with photocontrol and
timer to limit hours of use
CATALOG
NO. UPC
CODE INPUT SUPPLY (VAC)
50/60 Hz OUTPUT
CONTACTS ENCLOSURE
TYPE
LDS-A 81026 120/208-240/277 SPDT Metal Indoor
NEMA 1
LDS 81025 120/208-240/277 SPDT Mechanism
LDSH-A 81031 120/208-240/277 SPDT Metal Indoor
NEMA 1
LDSH 81028 120/208-240/277 SPDT Mechanism
MAINTAINED INPUT WITH LOAD WARNING BLINK:
LDS Series controls output load contacts based on power applied
to the time switch input contact. At removal of power from
the time switch input, LDS Series provides 1 second blink then
keeps load contacts closed for an extra 1 or 5 minutes (user
selectable) before turn off.
MAINTAINED INPUT WITH AUXILARY WARNING:
LDSH Series controls output load contacts based on power
applied to the time switch input contact. At removal of power
from the time switch input, LDSH Series closes a second set of
contacts for a user supplied audible or visual warning device.
The warning circuit closes for a selected time of 4 seconds (best
for audible device or continuous, then keeps load contacts closed
for an extra 1 or 5 minutes (user selectable) before turn OFF.
MOMENTARY INPUT: Provides timed override when time
switch input contact is unpowered (timer OFF). When activated
during the warning period, load contacts are kept closed and
timing starts. Both series can accept momentary input contact
closure for ON to start the timing and OFF to end the timing.
TIMED OVERRIDE SETTINGS: User may select override
times of
1
2
, 1, 1
1
2
, 2, 6, 9, or 12 hours. Warning before OFF is
always active after override time.
®
®®
®
ADD A WARNING BLINK
TO ANY CONTROL
WIRING DIAGRAMS
TORK 84
CONTACT RATINGS
SPECIFICATIONS
INPUT VOLTAGE:
120/208/240/277VAC, 50/60Hz.
TERMINAL RANGE: #10 - #16AWG.
OPERATING TEMPERATURE:
-22° to 150°F (-30° to +65°C).
POWER CONSUMPTION: 5VA Maximum.
ENCLOSURE: Metal Indoor NEMA 1 with
lockable hasp (see page 153 for dimensions).
TYPE VOLTAGE RATING
NO NC
General
Purpose 24/240VAC
277VAC 20A
20A 10A
3A
Ballast 120VAC
208-277VAC 20A
10A 10A
3A
Tungsten 120-277VAC 5A 3A
Pilot Duty 120-240VAC
27VAC 470VA
690VA 275VA
Resistive 28VDC 20A 10A
OFF
ON
NO CNC
REMOTE
INPUT
TIME SWITCH
INPUT
MAIN LOAD OUTPUT
TERMINALS
INPUT POWER
MOMENTARY
PUSH-BUTTON SWITCH
LOAD
HN N 120 208
240
277
VAC
NC NO C
H
N
H
N
TORK TIME SWITCH
OUTPUT TERMINALS
C ON OFF
DO NOT APPLY
VOLTAGE
OFF
ON
NO CNC
REMOTE
INPUT
TIME SWITCH
INPUT
MAIN LOAD OUTPUT
TERMINALS
MECHANICALLY HELD
CONTACTOR WITH
COIL CLEARING
CONTACTS
INPUT POWER
MOMENTARY
PUSH-BUTTON SWITCH
HN N 120 208
240
277
VAC
NC NO C
H
N
H
N
TORK TIME SWITCH
OUTPUT TERMINALS
C ON OFF
DO NOT APPLY
VOLTAGE
ON
OFF
COMMON
LDS WIRING
OFF
ON
NO CNC
REMOTE
INPUT
TIME SWITCH
INPUT
AUX. OUTPUT
TERMINALS
MAIN LOAD OUTPUT
TERMINALS
INPUT POWER
MOMENTARY
PUSH-BUTTON
SWITCH
AUX
LOAD LOAD
HN N 120
120 VAC
120 VAC
208
240
277
VAC
NC NC NO NO CC
H
N
H
N
H
N
TORK TIME SWITCH
OUTPUT TERMINALS
C ON OFF
DO NOT APPLY
VOLTAGE
OFF
ON
NO CNC
REMOTE
INPUT
TIME SWITCH
INPUT
AUX. OUTPUT
TERMINALS
MAIN LOAD OUTPUT
TERMINALS
INPUT POWER
MOMENTARY
PUSH-BUTTON
SWITCH
AUX
LOAD
HN N 120 208
240
277
VAC
NC NC NO NO CC
H
N
H
N
H
TORK TIME SWITCH
OUTPUT TERMINALS
C ON OFF
DO NOT APPLY
VOLTAGE
MECHANICALLY HELD
CONTACTOR WITH
COIL CLEARING
CONTACTS
N
OFF
COMMON
ON
LDSH WIRING
CNONC
ON NOFF
NC C
AUXILLARY
OUTPUT
TORK TIME SWITCH
OUTPUT TERMINALS
PHOTOCONTROL
SWITCHED CIRCUIT
TO TENNIS COURT
LIGHTS
SWITCHED CIRCUIT
TO TENNIS COURT LIGHTS
MECHANICALLY-HELD
4 POLE LIGHTING
CONTACTOR
480V CIRCUITS FROM PANEL
MAIN LOAD
OUTPUT
REMOTE INPUT
LDSH
FLASHING LIGHT
MOMENTARY
PUSHBUTTON
SWITCH
NO
CH
H
N
N
CNO NC
N
N
N
H
120V
120V
120V
120 208/240277OFFON
INPUT POWERTIME SWITCH INPUT
N
ON
OFF
APPLICATION WIRING
APPLICATION EXAMPLE
Lighting for a high school’s tennis courts
turns on during normal class hours when
natural light diminishes using a 7 day
time switch and photocell. After 3pm, staff
members sometimes use the courts (the time
switch is then off). A momentary pushbutton
activates the LDSH for timed override of
HID lighting. Five minutes before the lights
go out, an auxiliary contact flashes an
incandescent warning beacon (HID lighting
can not be made to blink). Additional
timed override can be arranged for via the
momentary pushbutton.
TORK 85
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
Signaling
Duty cycle
DGS SERIES
SIGNALING AND DUTY CYCLE
24 HOUR OR 7 DAY
TIME SWITCH
CATALOG
NO. UPC
CODE INPUT SUPPLY (VAC)
50/60 Hz NO. OF
CHANNELS OUTPUT
CONTACTS
24 HOUR MODELS
DG180A 82206 120-277VAC 1DPDT
DG280A 82207 120-277VAC 2SPDT
DG280A-24 82220 24VAC 2SPDT
7 DAY MODELS
DGS100A 82205 120-277VAC 1DPDT
DGS100A-12 82218 12VDC 1DPDT
DGS100A-24 82219 24VAC 1DPDT
DG180A & DG280A: 56 ON & OFF set points provide
individual daily programs. Minimum setting is 1 minute.
DGS100A: 56 ON & OFF set points provide individual programs
for each day of the week. Minimum setting is 1 minute.
DUTY CYCLE: Two different ON/OFF patterns or signal
durations may be programmed. The durations can be up to 23
hours, 59 minutes and 59 seconds in length.
SKIP FUNCTION (24 HOUR UNITS ONLY): Each channel
can be set for ACTIVE/SKIP operations that alternate from 1 - 31
days. This becomes an effective way to cycle loads on varying
days within the month. Using the two-circuit DG280A, two loads
can be set to operate on alternate days in a simple manner.
DAYLIGHT SAVING: Automatic adjustment (can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next regularly scheduled ON
or OFF, automatic operation then resumes.
CLOCK FORMAT: AM/PM or 24 hour.
POWER OUTAGE BACKUP: Permanent schedule retention.
Supercapacitor provides 7 days of real time backup.
31 DAY CYCLE TIME:
AN INDUSTRY FIRST!
NEW!
TORK 86
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE:
120 - 277 VAC, 50/60 Hz (auto detection).
TERMINAL RANGE: #12 - #18AWG.
OPERATING TEMPERATURE:
-31°F to +131°F (-35°C to + 55°C).
POWER CONSUMPTION: 6VA Maximum.
ENCLOSURE: Noryl® Indoor/Outdoor NEMA
3R with lockable hasp (see page 153 for
enclosure dimensions).
TYPE VOLTAGE RATING
NO NC
Resistive 24-277VAC 20A 10A
Ballast 120VAC
277VAC 20A 10A
Tungsten 120 VAC 15 A
Pilot Duty 120 VAC
240VAC 720VA 290VA
360VA
Motor 120VAC
240VAC 1HP
2HP
1
4
HP
1
2
HP
Resistive 28VDC 20A 10A
SPECIFICATION WRITER’S GUIDE
DGS100A SERIES –1. Furnish and install, where noted, a 1 channel 7 day programmable digital time switch. (Alt 1 DG180 Series 1. Furnish and install, where noted,
a 1 (2) channel 24 hour programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Unit shall be capable of
switching 20 amps ballast load at 277VAC. 4. Controller shall be capable of 56 set points; separate scheduling for each day of the week with one minute resolution. 5.
unit shall be capable of two duty cycle or signal durations from 1 second to 23 hours, 59 minutes and 59 seconds. 6. Controller shall be able to select USA Standard
Daylight Saving, Standard time or programmable dates. 7. Controller shall have automatic Leap Year correction. 8. Controller shall have Permanent Schedule Retention.
9. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 10. Controller shall be capable of Manual Override ON and OFF
to the next scheduled event using 1 button for each channel. 11. Unit shall have NEMA type 3R indoor/outdoor enclosure as standard. 12. To order specify TORK Model
DGS100A (Alt 12. Controller shall have a 31 day cycle to alternate days that programs are active or to be omitted. 13. To order specify TORK Model DG180A [DG280A]).
120/277VAC 120/277VAC
120/277VAC
120/277VAC 120/277VAC
120/277VAC
PERFECT FOR
PROCESS CONTROL
TORK 87
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
EJWT & E500T
SERIES
DELAY, INTERVAL &
PERCENTAGE TIME CYCLE
TIME SWITCHES
Poultry and livestock
Agriculture or greenhouse
Oil well pumping
Ventilation
Process control
CATALOG
NO. UPC
CODE INPUT SUPPLY (VAC)
60 Hz OUTPUT
CONTACT
EJWT 82513 120-240VAC SPDT
E500T 82514 120-240VAC SPDT
E501T 82515 120-240VAC SPDT
E502T 82516 120-240VAC SPDT
EJWT – PERCENTAGE TIMER
• 960 time combinations with two dials.
• Cycle Time Dial sets 32 repeating cycles from
15 seconds to 24 hours.
• Percentage ON Dial has 32 steps from 0%
to 100%.
• Repeats cycle as long as power is applied.
E500T – ON DELAY TIMER
• Dial sets 32 time delay durations from
5 seconds to 3 hours.
• External switch activated starts delay to ON.
• Runs until external switch turns OFF.
E501T – AUTO OFF INTERVAL TIMER
• Dial sets 32 time durations from 10 seconds
to 12 hours.
• Start/Stop button or External switch starts
interval ON.
• Automatically turns OFF at end of preset time.
• START/STOP or External switch turns OFF.
E502T – OFF DELAY TIME
• Dial sets 32 time durations from 5 seconds
to 3 hours.
• External switch starts interval ON.
• Automatically turns OFF at end of preset time.
• External switch turns OFF.
EJWT
E502T
E501T
NEW!
WIRING DIAGRAMS
EJWT
E500T / E501T / E502T
EJWT
E500T / E501T / E502T
TORK 88
CONTACT RATINGS
SPECIFICATIONS
TIMING ACCURACY: 1% of timing range.
INPUT VOLTAGE: 120/240VAC, 60Hz.
TERMINAL RANGE: #12 - #18AWG.
OPERATING TEMPERATURE:
32°F to +122°F (0°C to + 50°C).
POWER CONSUMPTION: 16VA Maximum.
ENCLOSURE: Indoor NEMA 4X is standard (see
page 153 for enclosure dimensions).
TYPE VOLTAGE RATING
NO NC
General Purpose 120-240VAC 20A 10A
Resistive 120-240VAC 20A 10A
Motor 120VAC
208-240VAC
1HP
2HP
1
4
HP
1
2
HP
Pilot Duty 120/240VAC 470VA 275VA
CALIFORNIA Title 24
ASHRAE 90.1
CALIFORNIA Title 24
ASHRAE 90.1
TORK 89
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
DIN SERIES
1 OR 2 CHANNEL
7 DAY TIME SWITCH
Panel builders
Indoor/Outdoor lighting
Security systems
HVAC equipment
SCHEDULING: 8 ON and OFF pairs of set
points for DIN100B. 4 ON and OFF (CH A) and
3 ON and OFF (CH B) pairs of set points for
DIN200B. Individual programs on each day of
the week. Minimum setting is 1 minute.
MANUAL OVERRIDE: Until the next regular
scheduled ON or OFF, automatic operation then
resumes.
CLOCK FORMAT: AM/PM.
POWER OUTAGE BACKUP: Battery retains
time and schedule.
CATALOG
NO. UPC
CODE DRY
CONTACTS CLOCK INPUT
50/60 Hz NO. OF
CHANNELS NUMBER OF
ON/OFF
DIN100B 82193 SPDT 120VAC 1 8
DIN200B 82192 SPDT 120VAC 24 Channel A
3 Channel B
DIN100B
DIN200B
PANEL BUILDERS
CHOICE
NEW!
WIRING DIAGRAMS
TORK 90
CONTACT RATINGS
SPECIFICATIONS
INPUT VOLTAGE: 120VAC, 50/60Hz.
TERMINAL RANGE: #12 - #18AWG.
OPERATING TEMPERATURE:
DIN100B: 14°- 131°F (-10°- +55°C).
DIN200B: 14°- 113°F (-10°- +45°C).
POWER CONSUMPTION: 4VA Maximum.
MOUNTING: DIN rail #50022 (35mm) or
flat surface using supplied adapter.
TYPE VOLTAGE RATING
NO NC
Resistive 120VAC 16A 16A
General Purpose 120VAC 8A 8A
Motor
(DIN100 only) 120VAC
1
2
HP
DIN100B DIN200B
DIN100B
35.80 55.00
45.00
85.00
46.00
60.00
DIN200B
D
Channel B (C2)
Channel A (C1)
NC
Input
NC
52.5
35.2
60
5
678
4
32
1
14
85
NO
NO
Channel A (C1)
Output
Channel B (C2)
Output
Channel B (C2)
Channel A (C1)
3
25
4
1
6
7
8
DIN200B
D
Channel B (C2)
Channel A (C1)
NC
Input
NC
52.5
35.2
60
5
678
4
32
1
14
85
NO
NO
Channel A (C1)
Output
Channel B (C2)
Output
Channel B (C2)
Channel A (C1)
3
25
4
1
6
7
8
DIN100B
35.80 55.00
45.00
85.00
46.00
60.00
WIRING DIAGRAMS
TORK 91
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
DIGITAL
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
SMC SERIES
MOMENTARY
CONTACT ADAPTER
Converts maintained contacts for
pulse switching
Timer to latching contactor control
Photocell to latching contactor control
Signaling
MAINTAINED INPUT: SMC3D accepts
maintained input power from any 120 volt
control. When power is applied or removed a
short contact closure (pulse) is created on the
dry output contacts.
MOMENTARY OUTPUT: SMC3D provides
two dry output contacts. The ON contact
provides a 2 second contact closure (pulse)
when power is applied to the input contacts.
The OFF contact provides a 2 second pulse
when power is removed from the input
contacts.
INPUT VOLTAGE: 120VAC, 50/60Hz.
TERMINAL RANGE: #12 - #18AWG.
OPERATING TEMPERATURE:
-31°F to +131°F (-35°C to + 55°C).
POWER CONSUMPTION: 6VA max.
ENCLOSURE: Noryl® Indoor/Outdoor
NEMA 3R with lockable hasp (see page
153 for dimensions).
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 50/60Hz OUTPUT
CONTACTS
SMC3D 52011 120 SPDT
Momentary
SPECIFICATIONS
CONTACT RATINGS
TYPE VOLTAGE RATING
NO NC
Resistive 120VAC 10A 10A
General Purpose 120VAC 10A 10A
Motor 120VAC
1
4
HP
NO CNC
H
N120VAC
PUSH ON
PUSH OFF
120
VAC
INPUT
NC NO
C
OFF RELAY
NH
NC NO
SMC 3D
ON RELAY
SMC 3D
Input – Sustained voltage 120VAC
Momentary Contacts (unpowered)
30 Amps inrush
120VAC, 240VAC
277VAC, 30VDC
LOW VOLTAGE
LATCHING RELAY
OR MECHANICALLY
HELD CONTACTOR
ON PULSE
OFF PULSE
NEUTRAL
120VAC
NO CNC
H
N
120
VAC
NC NO
C
OFF RELAY
NC NO
SMC 3D
ON RELAY
TORK DIGITAL CONTROL
TERMINAL BLOCK
MAINTAINED CONTACT INPUT
PUSH
ON
PUSH
OFF
ELECTRICALLY HELD CONTACTOR
OR MOTOR STARTER
LOAD LOAD LOAD
LLL
AUX
CONTACT
REALAY CONTACTOR
N
C
C
TORK DIGITAL CONTROL
TERMINAL BLOCK
MAINTAINED CONTACT INPUT
WIRING DIAGRAMS
APPLICATIONS
FEATURES
5401 SERIES
INCREASED AMPERAGE
& VOLTAGE SWITCHING
40 AMP CONTACTORS
Lighting loads
Exhaust fans
Electric and hot water heaters
Refrigeration and defrosting
CONTACT RATINGS: Can switch up to 40
AMPS per pole from 120VAC to 600VAC, one
to three circuits simultaneously.
EASY WIRING: Includes 120 volt control
wiring compartment. 5441 has terminal strip
pre-mounted for quick connection.
ENCLOSURE: 5401 - Metal NEMA 3
enclosure. 5441 - Metal NEMA 1 Indoor
enclosure (see page 153 for enclosure
dimensions).
ORDERING INFO
CATALOG
NO. UPC
CODE COIL
VOLTS NO. OF
CONTACTORS OUTPUT
CONTACTS
5401 81021 120 13PST
5441 81022 120 43PST
WIRING DIAGRAMS
24VAC
Control circuit from Time Switch
Wire other circuits B, C and D respectively
120 to 480VAC
Keep low voltage wires
inside this compartment.
Wire contactors
B, C and D
the same as A.
N
A
A
BCD
B
C
D
BLACK
WHITE
N
120VAC
Control circuit
from Time Switch
120VAC
208VAC
277VAC
480VAC
120VAC
208VAC
277VAC
480VAC
5401 5440 5441
{
{
120VAC
208VAC
277VAC
480VAC
{
120VAC
208VAC
277VAC
480VAC {
120VAC
Control circuit from Time Switch
Wire other circuits B, C and D respectively
120 to 480VAC
Keep low voltage wires
inside this compartment.
Wire contactors
B, C and D
the same as A.
N
A
A
BCD
B
C
D
120VAC
208VAC
277VAC
480VAC
{
120VAC
208VAC
277VAC
480VAC {
24VAC
Control circuit from Time Switch
Wire other circuits B, C and D respectively
120 to 480VAC
Keep low voltage wires
inside this compartment.
Wire contactors
B, C and D
the same as A.
N
A
A
BCD
B
C
D
BLACK
WHITE
N
120VAC
Control circuit
from Time Switch
120VAC
208VAC
277VAC
480VAC
120VAC
208VAC
277VAC
480VAC
5401 5440 5441
{
{
120VAC
208VAC
277VAC
480VAC
{
120VAC
208VAC
277VAC
480VAC {
120VAC
Control circuit from Time Switch
Wire other circuits B, C and D respectively
120 to 480VAC
Keep low voltage wires
inside this compartment.
Wire contactors
B, C and D
the same as A.
N
A
A
BCD
B
C
D
120VAC
208VAC
277VAC
480VAC
{
120VAC
208VAC
277VAC
480VAC {
5401
5441
TORK 92
SPECIFICATIONS
CONTACT RATINGS
TYPE VOLTAGE RATING
Resistive 120-600VAC 50A
FLA 120-600VAC 40A
Motor
120VAC
240VAC
480VAC
600VAC
3HP
7.5HP
20HP
25HP
Coil Data: 120VAC @ 60Hz
6VA Holding/seal; 60VA inrush
APPLICATIONS
FEATURES
WIRING DIAGRAMS
HPS STARTER
FOR HIGH PRESSURE SODIUM LAMPS
STARTING AID
DIGITAL
CONTROLS
TORK 93
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
ORDERING INFO
CATALOG
NO. UPC
CODE DESCRIPTION
HPS30 81030 High Pressure Sodium Starter
Designed to operate as a starting aid, for all
H.P.S. ballasts from 35 to 400 watts, with lamp
voltage of 55 or 100 volts.
LINE VOLTAGE: 105 - 347VAC.
LAMP VOLTAGE: 55 or 100VAC.
LAMP WATTAGE: 35 to 400 watts.
OPERATING TEMPERATURE:
-40°F to +221°F (-40°C to + 105°C).
LEAD LENGTH: 9 inches.
ENCLOSURE: Durable, high temperature
Lexan® housing.
SMART VOLTAGE: Delivers appropriate
trigger spikes for lamp ignition, then reduces
voltage to good lamps. Continues to feed
voltage spikes to old or poorly working
lamps.
HIGH GRADE MATERIAL: All components
are sealed with high grade die-electric
material to protect against contaminants and
other adverse environmental conditions.
EASY INSTALLATION: Universal 3 wire
design, color coded for ease of installation.
BLACK
BALLAST
RED
TAP
H.P.S.
STARTER
WHITE
CENTER
CONTACT
LAMP
SHELL
COMMON
LINE
SPECIFICATIONS
SURGE SUPPRESSOR
FOR HIGH ELECTRICAL NOISE
APPLICATIONS
APPLICATIONS
SPECIFICATIONS
TRP SERIES
LOW VOLTAGE SWITCHING
TRANSFORMER RELAY
POWER PACKS
TORK 94
ORDERING INFO
CATALOG
NO. UPC
CODE DESCRIPTION
90058-1 81024 Surge Suppressor
ORDERING INFO
CATALOG
NO. UPC
CODE DESCRIPTION INPUT
VOLTAGE
TRP-1** 82032 Single Transformer
Relay Powerpack 120VAC
TRP-2** 82033 Single Transformer
Relay Powerpack 277VAC
TRP400* 82132 Four Transformer
Relay Powerpack 120VAC
TRP402* 82133 Four Transformer
Relay Powerpack 277VAC
TRP800* 82135 Eight Transformer
Relay Powerpack 120VAC
TRP802* 82136 Eight Transformer
Relay Powerpack 277VAC
*Not for use with occupancy sensors.
**For replacement parts only. For newer style Transformer Relay Power Pack, see
TRP-U on page 116.
Low voltage switching of line voltage
lighting circuits up to 20 Amp ballasts or
15 amp tungsten loads. Also up to 1.0 HP
motors for ventilating and exhaust fans.
Low voltage switching by digital or
mechanical controls for higher amperage
loads including those of two different
voltages.
For high electrical noise
interference, recommended
for all digital controls.
CONTACTS: SPST contacts.
CONTACT RATING:
20 Amps Ballast @ 120 or 277VAC.
15 Amps Tungsten @ 120VAC.
1.0 Horsepower @ 120VAC.
TEMPERATURE RANGE:
0° to 150°F (–18° to 66°C).
WEIGHT: 7 oz.
ENCLOSURE: Metal NEMA 1 Indoor
enclosure (see page 153 for enclosure
dimensions).
SPECIFICATIONS
Pre-wired in metal enclosure.
IN-WALL TIMERS
FEATURES
QUICK LOOK
TORK 97
SS700Z SS721Z SS720A 701A SSA SSA-R24 SS D1060
D212 A C
Page No. 99 99 98 101 102 102 103 104 105 106
Timer Type 7 Day
Digital
7 Day
Digital
7 Day
Digital
24 Hour
Mechanical
Auto OFF
Digital
Auto OFF
Digital
Auto OFF
Electronic
Auto OFF
Electronic
Auto OFF
Mechanical
Auto OFF
Mechanical
Voltage 120/277 120/277 120 120 120/277 24 24/120/
208-240/277 120 125/250/277 125/250/277
Minimum
Settings
ON 1 min. 1 min. 1 min. 30 min. 5 min-12 hr
10 min-8 hr
5 min-12 hr
10 min-8 hr 1 min-18 hr 10-60 min.
2-12 hr
Various
2 min-12 hr
Various
2 min-12 hr
OFF 1 min. 1 min. 1 min. 30 min.
Manual Override Yes Yes Yes Yes
Sunrise/Sunset Yes Yes
ON/OFF Set Points 10 Pair 10 Pair 7 Pair 24
Flash Warning Yes Yes Yes
Audible Warning Yes Yes Yes
Power Outage Backup Capacitor Capacitor Battery Capacitor Capacitor
Switch Type SPST SPST SPST SPST SPST SPDT SPST or SPDT SPST SPST SPST or DPST
Resistive Ratings 16A 16A 15A 15 & 20A 800W/1200W 1A 4A or 7.5A 15 20/10/10A 20/10/10A
APPLICATIONS
FEATURES
ORDERING INFO
CONTACT RATINGS
SS720A SERIES
24 HOUR OR 7 DAY
DIGITAL IN-WALL
TIME SWITCH
Outdoor security lighting
Interior lights for lived-in look
Fans and motors
Appliances
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60 Hz COLOR
SS720A 14017 120 White
SS720AA 14018 120 Light Almond
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE: 125VAC, 60Hz.
WIRE SIZE: #14AWG.
OPERATING TEMPERATURE:
32°F to +104°F (0°C to +40°C).
TYPE VOLTAGE RATING
General Purpose 120VAC 15A
Resistive 120VAC 15A
Tungsten 120VAC 15A
Motor 120VAC 1HP
Electronic Ballast 120VAC 500VA
SCHEDULING: 7 ON and OFF pairs of set
points for individual programs on each day of
the week. Minimum setting is 1 minute.
RANDOM MODE: Varies ON and OFF
times to create "lived in" look when away.
DAYLIGHT SAVING: Manual button push
for one hour adjustment.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
WIRING: Requires a neutral.
CLOCK FORMAT: AM/PM.
POWER OUTAGE BACKUP: Rechargeable
Ni-MI battery retains time and schedule.
WALL PLATE: Supplied with standard single
gang decorator wall plate.
SPECIFICATIONS
TORK 98
NEW!
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
TORK 99
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
IN-WALL TIMERS
APPLICATIONS
FEATURES
ORDERING INFO
SS700Z & SS721Z
SERIES
SUNSET / SUNRISE, ASTRONOMIC
7 DAY IN-WALL TIMER
With wall plate
(not included)
Outdoor security lighting
Interior lights for lived-in look
Fans and motors
Appliances
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 50/60 Hz SWITCH
TYPE COLOR
SS700Z 14019 120/277 SPST White
SS700ZA 14020 120/277 SPST Light Almond
SS721Z 14027 120/277 SPST White
SS721ZA 14028 120/277 SPST Light Almond
SCHEDULING: 10 ON and OFF pairs of
set points for individual programs on each
day of the week. 11 day groups speed
programming. Minimum setting is 1 minute.
ASTRONOMIC: Sunset and sunrise times
are adjustable from 10°- 60° Northern
or Southern latitudes. Can be individually
offset +/- 1-240 minutes for earlier or later
operation.
RANDOM MODE: Varies ON and OFF
times to create lived in look when away.
DAYLIGHT SAVING: Automatic
adjustment (can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
MANUAL MODE: Does not run programs
until set to AUTO (automatic) mode.
VACATION MODE: No operation when
away.
EASY WIRING:
SS700Z does not require a neutral, can be
used as a 3-way switch.
SS721Z Requires a neutral, can be used as
a 3-way switch.
CLOCK FORMAT: AM/PM.
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides 2
days of real time backup.
COMMERCIAL GRADE SPECS: Control
lighting contactors and 277VAC loads.
Compatible with CFL lamps.
NEW!
BACKUP WITHOUT
BATTERY, ECO FRIENDLY!
ORDERING INFO
CONTACT RATINGS
CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TORK 100
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE: 120/277VAC, 50/60Hz.
WIRE SIZE: #12AWG input/output - #16AWG
3-way (remote).
OPERATING TEMPERATURE:
32°F to +104°F (0°C to + 40°C).
SS700Z SERIES VOLTAGE SS721Z SERIES
TYPE RATING RATING
Resistive 16A 120/277VAC 16A
Ballast 10A 120/277VAC 13A
Tungsten 8A 120VAC 8A
Pilot Duty 360VA 120VAC 720VA
Motor
1
2
HP 120VAC 1HP
H
NN
Black
Ground
Green
Blue
White
Load
Traveler A
Traveler B
Black
Red
Black
WIRING DIAGRAM: THREE-WAY INSTALLATION SS721Z
Connect a wire inside the gang-box between Traveler A and Hot.
WIRING DIAGRAM: INSTALLATION SS721Z
H
N
Load
Ground
Black
Red
Blue
White
Black
Green
N
APPLICATIONS
FEATURES
SPECIFICATIONS
ORDERING INFO
CONTACT RATINGS
701A & 711A SERIES
24 HOUR
IN-WALL TIME SWITCH
Porch or patio
Doorway
Pool
Outdoor security lighting
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60 Hz COLOR
701A 10113 125 White
701AA 10118 125 Light Almond
711A 10114 125 White
INPUT VOLTAGE: 125VAC, 60Hz.
WIRE SIZE: #14AWG.
OPERATING TEMPERATURE:
32°F to +104°F (0°C to +40°C).
TYPE VOLTAGE RATING
701A SERIES 711A SERIES
General Purpose 125 VAC 20A 15A
Resistive 125 VAC 20A 15A
Tungsten 125 VAC 1500W 1250W
Motor 125 VAC 1 HP
1
2
HP
SCHEDULING: Minimum ON setting is
30 minutes. Dial has 48 captive trippers.
BYPASS SWITCH: Slide switch for ON,
OFF, or TIMER (automatic) operation.
VACATION MODE: Set timer OFF with
no change of tripper settings.
WIRING: Requires a neutral.
CLOCK FORMAT: AM/PM marked on
dial.
WALL PLATE: Supplied with single gang
wallplate.
TORK 101
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
IN-WALL TIMERS
SPECIFICATIONS
NEW!
APPLICATIONS
FEATURES
SPECIFICATIONS SPECIFICATIONS
WIRING DIAGRAMS
TORK 102
SSA SERIES
DIGITAL AUTO OFF
IN-WALL
TIME SWITCH
Offices, meeting rooms, library aisles
Stock and equipment rooms
Exhaust fans – work areas, utility
rooms, bathrooms
Hot tub heaters and circulating pumps
Timed override lighting and HVAC for
after hours and for loads controlled
by electromechanical or digital time
switches.
ORDERING INFO
CATALOG
NO. UPC
CODE INPUT SUPPLY TIME
SETTINGS OUTPUT
CONTACTS
SSA100 14010 120/277 VAC Minutes: 5, 15, 30
Hours: 1, 3, 6, 9, 12 SPST
SSA200 14011 120/277 VAC Minutes: 10, 20, 40
Hours: 1, 1
1
2
, 2, 4, 8 SPST
SSA100R-24 14014 24VAC/24VDC Minutes: 5, 15, 30
Hours: 1, 3, 6, 9, 12 SPDT
SSA200R-24 14015 24VAC/24VDC Minutes: 10, 20, 40
Hours: 1, 1
1
2
, 2, 4, 8 SPDT
LCS115M 82082 Momentary Switch
for Override (white) SPST
TIMING ACCURACY: .002%.
INPUT VOLTAGE:
120/277 VAC, 50/60Hz.
WIRE SIZE: #18AWG.
OPERATING TEMPERATURE:
F to +100°F (-17°C to +37°C).
CONTACT RATINGS
8-IN-1 TIMING: Choose from 8 preset ON
intervals.
MANUAL SCROLL-UP: Option allows
adjustment in 10 minute intervals.
FLASH WARNING: Optional flicker feature
turns load off for 1 second, 2 minutes before
end of timed cycle and again 1 minute before
end of timed cycle.
AUDIBLE WARNING: Optional beep will
sound every 12 seconds during the last 2
minutes of timed cycle.
TAMPER RESISTANT: Time ON interval
preset hidden behind wall plate.
EASY SET: Dip switches provide quick set-up
of timing and options.
EASY WIRING: No neutral needed, great
for retrofit.
BACKLIT DISPLAY: Numerical read-out of
time remaining includes graphic bar showing
time remaining in 10% increments. Stands out
strongly in lighted and dark areas.
WALL PLATE: Supplied with white standard
single gang decorator wall plate.
SSA-R24: Offers low voltage control with
SPDT output and includes momentary input.
SSA200R-24
USING TRP TRANSFORMER RELAY POWERPACK
BLACK
ORANGE
BLUE
GREY
NC
C
NO
RED
YELLOW
YELLOW
(+)
(–)
24VAC
or
VDC
REMOTE
OVERRIDE
BLACK
BLACK
ORANGE
BLUE
BLUE
GREY
NC
C
NO
NL
L
RED
YELLOW
YELLOW
WHITE
BLACK
20 AMP
LOAD
REMOTE
OVERRIDE
TORK
TRP
RED
RED
LOW
VOLTAGE
RED
BLACK
GREEN
GREEN /YELLOW
RED LOAD
HOT
120V GROUND
277V GROUND
NEUTRAL
SSA100/200
TYPE VOLTAGE RATING
SSA100/200
Tungsten 120VAC 800W
Ballast 120VAC
277VAC
800W
1200W
Motor 120VAC
1
6
HP
Pilot Duty 120VAC 240VA
SSA100/200R-24 30V
1V min.
30V
1V min.
1A
100µA
APPLICATIONS
FEATURES
SS SERIES
AUTO OFF
IN-WALL TIME SWITCH
*Flicker feature turns load OFF for ½ second, 2 minutes before end of timed cycle and again 1 minute
before end of timed cycle.
**Beep feature will begin a ½ second audible warning every 12 seconds during the last 2 minutes of
timed cycle.
*Not compatible with compact fluorescent lamps (CFL) and electronic fluorescent ballasts.
Bathroom fans and lights
Indoor/Outdoor lighting
Storage areas
Hospitality areas
ORDERING INFO
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 50/60Hz WARNING BEFORE
TIME OUT SWITCH
TYPE
SS20 14005 24/120/208-240/277 None Single pole
SS20F 14008 24/120/208-240/277 *Flicker Single pole
SS13F 14007 24/120/208-240/277 *Flicker 3-way
SS13B 14006 24/120/208-240/277 **Beep 3-way
TIMING ACCURACY:
±5% @ 60° to 80°F.
INPUT VOLTAGE:
24/120/208-240/277VAC, 50/60Hz.
WIRE SIZE: #18AWG.
OPERATING TEMPERATURE:
F to +100°F (-17°C to +37°C).
CONTACT RATINGS
VARIABLE TIMING: Choose from 1 minute
to 18 hours.
FLASH WARNING: “F” suffix models with
flicker feature turns load off for
1
2
second, 2
minutes before end of timed cycle and again 1
minute before end of timed cycle.
AUDIBLE WARNING: “B" suffix model will
buzz that every 12 seconds during the last 2
minutes of timed cycle.
TAMPER RESISITANT: Time ON interval
preset is hidden behind wall plate.
EASY SET: Small screw driver adjustment
provides quick set-up of timing.
EASY WIRING: No neutral needed, great
for retrofit.
3-WAY: SS13 SERIES replaces standard
3-way switch with no re-wiring.
COLOR: White.
TYPE CONTACT
RATINGS
MINIMUM LOAD
VOLTS WATTS
SS13F &
SS13B
.25-4.0A Resistive 24 6
.25-4.0A Ballast* 120 30
.25-4.0A Tungsten 208 50
1
8
HP @ 120VAC 240 60
1
3
HP @ 240VAC 277 70
SS20 &
SS20F
.50-7.25A Resistive 24 12
.50-7.25A Ballast* 120 60
.50-4.0A Tungsten 208 105
1
6
HP @ 120VAC 240 120
1
2
HP @ 204VAC 277 150
TORK 103
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
IN-WALL TIMERS
SPECIFICATIONS
APPLICATIONS
FEATURES
SPECIFICATIONS
TORK 104
D SERIES
ELECTRONIC AUTO OFF
IN-WALL TIME SWITCH
Whole house fans
Indoor/Outdoor lighting
Bathroom fans and lights
Self storage
ORDERING INFO
CATALOG
NO. UPC
CODE
INPUT
SUPPLY
(VAC) 60Hz
TIME
SETTINGS OUTPUT
CONTACTS
D212H 14021 120 Ivory 2, 4, 8, 12 HOURS
D212HA 14022 120 Light Almond 2, 4, 8, 12 HOURS
D212HW 14023 120 White 2, 4, 8, 12 HOURS
D1060M 14025 120 Ivory 10, 20, 30, 60 MINUTES
D1060LA 14024 120 Light Almond 10, 20, 30, 60 MINUTES
D1060MW 14025 120 White 10, 20, 30, 60 MINUTES
TIMING ACCURACY: Line voltage.
INPUT VOLTAGE: 120VAC, 60Hz.
WIRE SIZE: #14AWG.
OPERATING TEMPERATURE:
32°F to 122°F (0°C to 50°C).
CONTACT RATINGS
VARIABLE TIMING:
Button push changes time ON setting.
D1060M: 10, 20, 30, 60 minute.
D212H: 2, 4, 8, 12 hour.
LED DISPLAY: Indicator moves to new range
as timer counts down.
TAMPER RESISTANT: Time ON interval preset.
EASY SET: No adjustments, just wire and go!
WIRING: Requires a neutral.
THREE COLORS: Ivory, Light Almond, White.
TYPE VOLTAGE RATING
General Purpose 120VAC 15A
Resistive 120VAC 1000W
Tungsten 120VAC 1000W
Motor 120VAC
1
4
HP
SPECIFICATIONS
NEW!
APPLICATIONS
FEATURES
A SERIES
SPRINGWOUND AUTO OFF
IN-WALL TIME SWITCH
Whole house fans
Indoor/Outdoor lighting
Bathroom fans and lights
Self storage
INPUT VOLTAGE:
125/250/277VAC, 50/60Hz.
TERMINAL SIZE: #12AWG.
OPERATING TEMPERATURE:
32°F to 122°F (0°C to 50°C).
VARIABLE TIMING: Twist knob for time
ON setting. Time ON lengths from 15 minutes
to 12 hour vary by model.
HOLD FEATURE: Some models have position
for constant ON.
EASY SET: No adjustments. Just wire and go!
EASY WIRING: No neutral required. Great
for retrofit! Use as single or in multi-gang box
with no de-rating.
SWITCH TYPE: SPST.
COLOR: Ivory, Light Almond, White.
WALL PLATE: Fits standard or decorator
style wall plates, see below (not included).
CONTACT RATINGS
TYPE VOLTAGE RATING
Resistive 125VAC
250VAC
277VAC
20A
10A
10A
Inductive 125VAC
250VAC
277VAC
20A
10A
10A
Tungsten 125VAC 7A
Motor 125VAC
250VAC 1HP
2HP
Wallplate not
included
TOP
9
12
0
0
3
69
12
12
12
12 3
0
96
TOR K
TOP
9
12
0
0
3
69
12
12
12
12 3
0
96
TOR K
TORK 105
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
IN-WALL TIMERS
SPECIFICATIONS
ORDERING INFO
CATALOG
NO. UPC
CODE HOLD
FEATURE COLOR
15 MINUTE MAX.
A515MH 15020
With Hold
Ivory
A515MHW 15120 White
A515M 15013
No Hold
Ivory
A515MW 15113 White
A515MA 15127 Light Almond
30 MINUTE MAX.
A530MH 15021
With Hold
Ivory
A530MHW 15121 White
A530M 15014
No Hold
Ivory
A530MW 15114 White
A530MA 15128 Light Almond
60 MINUTE MAX.
A560MH 15022
With Hold
Ivory
A560MHW 15122 White
A560M 15015
No Hold
Ivory
A560MW 15115 White
2 HOUR MAX.
A502HHW 15123 With Hold White
A502H 15016
No Hold
Ivory
A502HW 15116 White
6 HOUR MAX.
A506HHW 15125 With Hold White
A506H 15018
No Hold
Ivory
A506HW 15118 White
12 HOUR MAX.
A512HH 15026
With Hold
Ivory
A512HHW 15126 White
A512H 15019
No Hold
Ivory
A512HW 15119 White
All A Series timers have SPST switch type.
CAUTION: This timer is not to be used in precision timing applications where
inaccurate timing could have dangerous consequences (i.e. sun lamp, sauna, etc.).
APPLICATIONS
FEATURES
SPECIFICATIONS
TORK 106
Wallplate
included
C SERIES
COMMERCIAL STYLE
SRINGWOUND AUTO OFF
IN-WALL TIME SWITCH
Ventilating fans
HVAC
Whirlpools
Self storage
Motors and pumps
VARIABLE TIMING: Twist knob for time
ON setting. Time ON lengths from 15 minutes
to 12 hour vary by model.
HOLD FEATURE: Some models have position
for constant ON.
EASY SET: No adjustments. Just wire and go!
EASY WIRING: No neutral required. Great
for retrofit!
SWITCH TYPE: SPST, except C460M and
C412H – DPST
COLOR: Metal-brushed aluminum.
WALL PLATE: Includes real metal wall plate
with screw mounting, to add extra security for
commercial applications.
INPUT VOLTAGE:
125/250/277VAC, 50/60Hz.
TERMINAL SIZE: #12AWG.
OPERATING TEMPERATURE:
32°F to 122°F (0°C to 50°C).
CONTACT RATINGS
TYPE VOLTAGE RATING
Resistive 125VAC
250VAC
277VAC
20A
10A
10A
Inductive 125VAC
250VAC
277VAC
20A
10A
10A
Tungsten 125VAC 7A
Motor 125VAC
250VAC 1HP
2HP
ORDERING INFO
CATALOG
NO. UPC
CODE HOLD
FEATURE
15 MINUTE MAX.
C515M 15501 No Hold
30 MINUTE MAX.
C530M 15503 No Hold
60 MINUTE MAX.
C560M 15505 No Hold
C560MH 15506 With Hold
C460M* 15011 No Hold
2 HOUR MAX.
C502H 15507 No Hold
6 HOUR MAX.
C506H 15511 No Hold
12 HOUR MAX.
C512H 15513 No Hold
C512HH 15514 With Hold
C412H* 15010 No Hold
*DPST switch type.
SPECIFICATIONS
CAUTION: This timer is not to be used in precision timing applications where
inaccurate timing could have dangerous consequences (i.e. sun lamp, sauna, etc.).
NEW!
NEW!
OCCUPANCY SENSORS
A Passive Infrared Sensor (PIR sensor), is a device that measures infrared
radiation (IR), or heat, from objects in its field of view. Because it only receives
information, it is considered passive. The IR sensor views a human body as an
IR generating object. The lens of the occupancy sensor breaks up the field of
view into IR sensitive bands. The occupancy sensor is designed to only react
when heat is sensed moving from band to band. For PIR occupancy sensors to
work object must have direct “line of sight” to the PIR sensor.
An Ultrasonic Sensors (US sensor) is a technology that works on a principle
similar to radar or sonar. It is an active technology that sends and receives. It
emits an inaudible high-frequency sound wave and evaluates the echo which
is received back after bouncing around in the room. This allows the sensor to
evaluate the whole room and can “look” over walls and obstructions to identify
movement.
Both technologies show higher sensitivity closer to the sensor to allow small
movements to be noticed. Sensitivity reduces further away from the sensor and
may require a walking step to activate the sensor.
A Wall Switch Sensor provides a 180° coverage pattern, extending outward
from the sensor. This will allow for instant turn ON when an occupant enters the
space. Total area covered will be over 400 square feet.
Proper placement gives the sensor a clear line of sight to the entry door
without viewing the hallway.
The occupant must be able to see the sensor from their normal work position
otherwise the sensor will not be able to detect their presence.
For offices where there are other obstructions between the sensor and the
occupant or the entry door, a ceiling sensor is required.
TORK 109
SENSOR TECHNOLOGY
& PLACEMENT GUIDE
TECHNOLOGY
PIR AND ULTRASONIC
PLACEMENT GUIDELINES
CEILING SENSOR
PLACEMENT GUIDELINES
WALL SENSOR
A Ceiling Sensor provides a 360° coverage pattern of up to 1200
square feet when using passive infrared only. When using dual
technology the coverage pattern extends to over 2000 square feet.
Barriers within the space that block line-of-sight to sensor detection will
decrease coverage area when using passive infrared by itself, ultrasonic
dual technology will allow the sensor to get around the obstructions.
Designed for ceiling mounting at a height of 8-10 feet (mounting
sensor at greater heights decreases the sensitivity to motion, while
lower mounting height will decrease range).
The sensor needs a visually unobstructed view of the normally
occupied workspace and entry door(s).
Avoid sensor placement with a direct view out a doorway. Placing the
sensor offset from the center and away from the door is
recommended.
If the occupant cannot see a PIR sensor from their normal work
position, the sensor will not be able to detect their presence.
File cabinets, partitions, or walls are typical types of obstructions. If
there are other obstructions between the sensor and the occupant, an
ultra-sonic or dual technology ceiling sensor is recommended.
When the light level feature is used, mount within 15 feet of the
widows or skylight and avoid mounting the sensor close to lighting
fixtures.
Place the sensor no closer than 5 feet to an HVAC air duct when using
dual technology sensors.
Open office designs encourage placement of the sensors to allow
overlapping coverage of small motion range and a clear view into
each cubicle. Walking step motion may cover the entry to the space.
Dual technology units provide added sensitivity to small motion.
CEILING AND WALL OCC SENSOR SENSING PAT TERNS
CEILING AND WALL OCC SENSOR SENSING PAT TERNS
CEILING AND WALL OCC SENSOR SENSING PAT TERNS
APPLICATIONS
FEATURES
SPECIFICATIONS
ORDERING INFO
OSWS SERIES
PIR SENSOR, DECORATOR STYLE
IN-WALL
OCCUPANCY SENSOR
Offices and hotels
Classrooms
Conference rooms
Lavatories
Hallways
OSWS9P-120, OSWS9P-277 & OSWS9PD:
OPERATION: Automatic ON and automatic OFF
based on occupancy detection.
OFF DELAY: Selectable from 30 seconds to 30
minutes.
MANUAL OVERRIDE: Includes ON and OFF
switch.
EASY WIRING: No neutral required. Great for
retrofit.
OSWS9PD ALSO INCLUDES:
SENSITIVITY ADJUSTMENT: For PIR range.
DAYLIGHTING MODE: Adjustable level to
keep lights OFF even when occupancy is sensed if
adequate light exists in the room from windows or
skylights.
OSWS9PDM - VACANCY SENSOR:
OPERATION: Manual push button on and then
automatic OFF.
OFF DELAY: Selectable from 30 seconds to 30
minutes.
SENSITIVITY ADJUSTMENT: For PIR range.
DAYLIGHTING MODE: Adjustable level to
keep lights OFF even when occupancy is sensed if
adequate light exists in the room from windows or
skylights.
MANUAL OVERRIDE: Includes ON and OFF
switch.
EASY WIRING: No neutral required.
CONTACT RATINGS:
OSWS9P-120: 1000W Ballast, 800W
Incandescent,
1
6
HP at 120VAC.
OSWS9P-277: 1800W Ballast at 277VAC.
OSWS9PD & OSWS9PDM: 1000W Ballast, 800W
Incandescent,
1
6
HP at 120VAC, 1800W Ballast
at 277VAC.
ADJUSTABLE TIME DELAY:
30 seconds - 30 minutes.
OPERATING TEMPERATURE:
32° to 131°F (0° to 55°C).
MOUNTING: Box mount.
CATALOG
NO. UPC
CODE DESCRIPTION OUTPUT
CONTACTS
OSWS9P-120 82077 PIR in-line wall switch 120VAC
OSWS9P-277 82078 PIR in-line wall switch 277VAC
OSWS9PD 82079 PIR in-line wall switch
with ambient light sensor 120/277VAC
OSWS9PDM 82080 PIR in-line wall switch
manually activated 120/277VAC
Wall Mounting Box
LOAD
(Red)
LINE
(Black)
GND
(Green)
35'
180° Coverage
4.0'
15°
15°
16'
35'
Top and Side Coverage Pattern Diagrams
WIRING & COVERAGE DIAGRAMS
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
TORK 110
TORK 111
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
OCCUPANCY
SENSORS
APPLICATIONS
FEATURES
ORDERING INFO
SPECIFICATIONS
WIRING & COVERAGE DIAGRAMS
OSC15PLS
PIR SENSOR, WITH AMBIENT LIGHT
OVERRIDE, MULTI-VOLTAGE
INTEGRAL POWERPACK,
CEILING MOUNTED
OCCUPANCY SENSOR
Offices and hotels
Classrooms
Conference rooms
Lavatories
Hallways
OPERATION: Automatic ON and automatic
OFF based on occupancy detection.
OFF DELAY: Selectable from 30 seconds to
30 minutes.
DAYLIGHTING MODE: Selectable to
keeps lights off when occupancy is sensed
if adequate light exists in the room from
windows or skylights.
POWER SWITCHING: Built-in power pack
for direct line voltage control.
VOLTAGE: 120 - 347VAC.
ADJUSTABLE LIGHT LEVEL: 5FC - 200FC.
ADJUSTABLE TIME DELAY: 30 seconds -
30 minutes (DIP switch).
TEST MODE: 5 seconds, upon initial power-up
or DIP switch reset.
PIR COVERAGE: 1200 sq. ft.
SENSITIVITY ADJUSTMENT:
Full or 50% low (DIP switch).
OPERATING TEMPERATURE:
32° to 131°F (0° to 55°C).
MOUNTING: Ceiling or box mount.
CONTACTS: SPST dry contacts.
CONTACT RATINGS: 800W Incandescent,
1000W ballast at 120VAC. 1800W Ballast at
277VAC. 2200W Ballast at 347VAC.
CATALOG
NO. UPC
CODE INPUT
SUPPLY COVERAGE
(FEET) DESCRIPTION
OSC15PLS 82076 120-347VAC 1200 WHITE
RED
OSC15PLS
SENSOR
RED
WHITE (NEUTRAL)
BLACK (LINE)
NLOAD
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
APPLICATIONS
FEATURES
SPECIFICATIONS
OSC12PL
& OSC5PL
PIR SENSOR
CEILING MOUNTING
OCCUPANCY SENSORS
Offices
Classrooms
Conference rooms
Lavatories
Hallways
OPERATION: Automatic ON and automatic OFF
based on occupancy detection.
OFF DELAY: Selectable from 30 seconds to 30
minutes.
ECOSETTING: Learns typical use patterns and
adjusts the OFF delay for the most efficient time.
WALK-THROUGH MODE: Selectable to turn
lights OFF after only 3 minutes. If no activity is
detected after 30 seconds of occupancy detection,
lights turn OFF.
DAYLIGHTING MODE: Selectable to keep lights
OFF when occupancy is sensed if adequate light
exists in the room from windows or skylights.
PRESENTATION MODE: Optional MANUAL OFF
by an accessory wall switch (LCS115M). Sensor
will keep lights OFF while movement in room is
detected, then return to automatic ON after 5
minutes.
VACANCY MODE: Optional MANUAL ON by
an accessory wall switch (LCS115M) and then
automatic OFF.
MANUAL OVERRIDE: Optional manual control
by an accessory wall switch (LCS115M) for ON and
OFF.
WARNING BEFORE OFF: Optional visual flash
warning and/or audible beep warning one minute
before turn OFF.
PLUG TERMINAL: Quick disconnect for sensor.
POWER SWITCHING: Transformer relay power
pack (TRP-U) required to power sensor and provides
line voltage switching. (see page 116 for product
information).
VOLTAGE: 24VDC.
CURRENT CONSUMPTION: 9mA.
POWER SUPPLY: TRP-U Power Pack
(up to 6 units).
ADJUSTABLE LIGHT LEVEL:
10FC - 150FC.
ADJUSTABLE TIME DELAY:
5 seconds - 30 minutes (DIP switch).
TEST MODE: 5 seconds, upon initial
power-up or DIP switch reset.
PIR COVERAGE: 1200 sq. ft.
SENSITIVITY ADJUSTMENT:
Full or 50% low (DIP switch).
MOUNTING: Ceiling or box mount.
OPERATING TEMPERATURE:
32° to 131°F (0° to 55°C).
ORDERING INFO
CATALOG
NO. UPC
CODE INPUT
SUPPLY COVERAGE
(FEET) DESCRIPTION
OSC5PL 82083 24VDC 500 White
OSC12PL 82081 24VDC 1200 White
TRP-U 82030 120/277VAC Power Pack
LCS115M 82082 Momentary Switch
OSC5PL / OCCUPANCY SENSOR ASSORTED SENSING PATTERNS
18ft
12ft
OSC12PL
OSC5PL / OCCUPANCY SENSOR ASSORTED SENSING PATTERNS
18ft
12ft
22
11 73 37 11
6.7
OSC5PL
SensitivityTime Delay
5 Sec/EcoSet
30 Seconds
5 Minutes
10 Minutes
15 Minutes
20 Minutes
25 Minutes
30 Minutes
Factory Setting
50%
100%
Disabled
Enabled
Walk Through
Disabled
Enabled
Visible Alert
Disabled
Enabled
Audible Alert
Disabled
Enabled
Hold ONVacancy
Disabled
Enabled
1234
5
6
7
8
9
OFF ON
DIP SWITCH
COVERAGE DIAGRAMS
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
SPECIFICATIONS
TORK 112
TORK 113
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
OCCUPANCY
SENSORS
APPLICATIONS
FEATURES
ORDERING INFO
SPECIFICATIONS
COVERAGE DIAGRAMS
OSC20UP
DUAL TECHNOLOGY
CEILING MOUNTED
PIR/ULTRASONIC
OCCUPANCY SENSOR
Offices and hotels
Classrooms
Conference rooms
Lavatories
Hallways
OPERATION: Automatic ON and automatic
OFF based on occupancy detection.
OFF DELAY: Selectable from 8 to 40
minutes.
ECOSETTING: Learns typical use patterns
and adjusts the OFF delay for the most
efficient time.
MOTION INDICATION: Red for infrared
motion, Green for ultrasonic motion.
Indicators may be disabled.
POWER SWITCHING: Transformer relay
power pack (TRP-U) is required to power
sensor and provide line voltage switching
(see page 116 for product information).
VOLTAGE: 24VDC.
CURRENT CONSUMPTION: 33mA.
POWER SUPPLY: TRP-U Power Pack
(up to 3 units).
ADJUSTABLE TIME DELAY:
8 - 40 minutes.
TEST MODE: 8 seconds, upon initial
power-up for 1 hour.
US COVERAGE: 2000 sq. ft. (adjustable).
PIR COVERAGE: 1500 sq. ft. (adjustable).
SENSITIVITY ADJUSTMENT: Individual setting
range for ultrasonic of 50% and PIR of 75%.
ULTRASONIC OUTPUT: 32Hz
MOUNTING: Ceiling or box mount.
OPERATING TEMPERATURE:
32° to 131°F (0° to 55°C).
HUMIDITY: 0 to 95% R.H. non-condensing for
indoor use only.
CATALOG
NO. UPC
CODE INPUT
SUPPLY COVERAGE
(FEET) DESCRIPTION
OSC20UP 82075 24VDC 2000 ft US
1500 ft PIR White
TRP-U 82030 120/277VAC Power Pack
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
APPLICATIONS
FEATURES
SPECIFICATIONS
COVERAGE DIAGRAMS
ORDERING INFO
SPECIFICATIONS
COVERAGE DIAGRAMS
TORK 114
OSC SERIES
ULTRASONIC, CEILING MOUNTING
OCCUPANCY SENSORS
Offices and hotels
Classrooms
Conference rooms
Lavatories
Hallways
OPERATION: Automatic ON and automatic
OFF based on occupancy detection.
OFF DELAY: Selectable from 8 to 40
minutes.
ECOSETTING: Learns typical use patterns
and adjusts the OFF delay for the most
efficient time.
MOTION INDICATION: Green for
ultrasonic motion. Indicator may be disabled.
POWER SWITCHING: Transformer relay
power pack (TRP-U) is required to power
sensor and provide line voltage switching
(see page 116 for product information).
VOLTAGE: 24VDC.
CURRENT CONSUMPTION: 33mA.
POWER SUPPLY: TRP-U Power Pack
(up to 4 units).
ADJUSTABLE TIME DELAY:
8 - 40 minutes.
TEST MODE: 8 seconds, upon initial
power-up for 1 hour.
US COVERAGE: 2000 sq. ft. (adjustable).
SENSITIVITY ADJUSTMENT: Manual
setting range of 50%.
ULTRASONIC OUTPUT:
OSC5U: 40kHz
OSC10U/OSC20U: 32kHz
MOUNTING: Ceiling or box mount.
OPERATING TEMPERATURE:
32° to 104°F (0° to 40°C).
HUMIDITY: 0 to 95% R.H. non-condensing
for indoor use only.
CATALOG
NO. UPC
CODE INPUT
SUPPLY COVERAGE
(FEET) DESCRIPTION
OSC5U 82072 24VDC 500 SQ FT White
OSC10U 82073 24VDC 1000 SQ FT White
OSC20U 82074 24VDC 2000 SQ FT White
TRP-U 82030 120/277VAC Power Pack
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
TORK 115
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
OCCUPANCY
SENSORS
APPLICATIONS
FEATURES
ORDERING INFO
SPECIFICATIONS
WIRING DIAGRAMS
ELS
INDOOR LIGHT LEVEL
ELECTRONIC
LIGHT
SENSOR
Offices
Classrooms
Conference rooms
Hallways
DAYLIGHTING CONTROL: Turns OFF
when sufficient daylight present.
ADJUSTABLE LIGHT LEVEL:
10FC - 250FC (DIP switch).
EASY MOUNTING: Low voltage Class 2
wiring allows recommended mounting about
3 feet from daylight sources.
ADJUSTABLE OFF DELAY:
Set from 3 to 15 minutes.
PRESET ON DELAY: 30 seconds prevents
false triggering.
VOLTAGE: 24VDC.
CURRENT CONSUMPTION: 9mA.
POWER SUPPLY: TRP-U Power Pack (up
to 4 units).
OPERATING TEMPERATURE:
50° to 104°F (10° to 40°C).
MOUNTING: Ceiling or box mount.
CATALOG
NO. UPC
CODE INPUT
SUPPLY DESCRIPTION
ELS-1 82049 24VDC Indoor Daylight Sensor
TRP-U 82030 120/277VAC Power Pack
PROGRAMMABLE 7-SECTION SLIDE SWITCH FOOT CANDLE SELECTION*
SLIDE FOOT CANDLE FOR
#1 10FC Warehouse
#2 25FC Corridors
#3 50FC Machine equipment display showroom (such as
automobile and farm equipment) LOBBY (such as
airport waiting area).
#4 75FC Classrooms, common office areas
#5 100FC Drafting rooms
#6 150FC Retail display areas
#7 250FC High critical areas, product sorting and grading,
paint quality control.
Power Pack 277V
Model TRP2
or Power Pack 120V
Model TRP1
New Cover With
1/2 K.O. Provision
New
Extension
Box
Existing
Junction
Box
Bend Tabs After
Inserting in K.O.
Hole
New Extension Box
Only Used When
Low Voltage Wiring
Has to be Enclosed
PHOTO SENSOR
ORIENTATION ARROW
UNDER IVORY COVER
+1324
567
ON
1324567
*Slide only one switch to ON for selection, all other switches remain OFF.
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
APPLICATIONS
FEATURES
SPECIFICATIONS
WIRING DIAGRAMS
ORDERING INFO
SPECIFICATIONS
WIRING DIAGRAMS
TORK 116
TRP-U
INTELLIGENT
POWER PACK VOLTAGE: 120/230/277VAC, 50/60Hz.
LOAD REQUIREMENTS:
Ballast 20amp @120/277VAC.
Incandescent 20amp@120VAC.
Motor 1HP @120/240VAC.
Output 150mA @24VDC (with relay connected).
LOW VOLTAGE INPUT:
Control ON: 12 - 24VDC
Hold ON: 12 - 24VDC
Hold OFF: 12 - 24VDC
MOUNTING: Box mount to
1
2
" KO.
OPERATING TEMPERATURE:
32° to 131°F (0° to 55°C).
CATALOG
NO. UPC
CODE INPUT
SUPPLY DESCRIPTION
TRP-U 82030 120/277VAC Power Pack
LCS115M 82082 Momentary Switch
Power and switching
for occupancy sensors
Power and switching
for SSA R-24 series
BAS input compatible
Demand shedding applications
Device override to hold on
Momentary switched override
Low voltage 3-way wiring
OPERATION: Switches line voltage loads ON/OFF
based on a contact closure from an occupancy sensor,
AUTO OFF switch, or relay.
INTELLEGENT INPUT: Three additional input wires:
1. Hold OFF for demand shed control.
2. Hold ON override of local devices such as sensors.
3. Momentary switch input for remote override.
MULTI-VOLTAGE: Tri-voltage input for flexibility.
QUICK MOUNTING: Snaps into
1
2
" box KO.
TRP-U
LOW VOLTAGE WIRING
PLUG-IN TIMERS
NOTE: " " = Indicates outlet location.
APPLICATIONS
FEATURES
ORDERING INFO
TORK 119
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
PLUG-IN TIMERS
Lamps, radios, televisions
Appliances
Automatically turn ON/OFF items
in the home, gives the home a
"lived in" look while away.
400A SERIES
INDOOR GENERAL PURPOSE 1875W
MECHANICAL MULTIPLE
ON/OFF TIMERS
REPEAT SCHEDULE: Daily.
VARIABLE TIMING: Multiple ON/OFF times.
ON/OFF: Manual ON/TIMER switch.
ENERGY SAVINGS: Works with CFLs and LED lamps. 403A
405A
422A
402A
401A
CATALOG
NO. UPC
CODE RATINGS NO. OF
OUTLETS
( )
TYPE OF
PLUG DESCRIPTION VARIABLE TIMING
SEGMENTS
401A 16001
125 VAC, 15A, 1875W Resistive
125VAC, 10A, 1250W Tungsten
125VAC,
1
3
HP
1 Polarized Multiple ON/OFF Lighting Timer 15 minute
402A 16002 1 Grounded Heavy Duty 24 hour Timer 15 minute
403A 16013 1 Polarized Powerful & Compact Automatic Timer 30 minute
405A 16014 2 Grounded Heavy Duty 15 AMP Automatic Timer 15 minute
422A 16019
125VAC 15A, 1875W Resistive
125VAC 500W Tungsten
125VAC TV-4
1 Grounded Heavy Duty 24 hour 15AMP Timer 30 minute
NEW!
NEW!
APPLICATIONS
FEATURES
ORDERING INFO
TORK 120
Lamps, radios, televisions
Appliances
Automatically turn ON/OFF items in
the home, gives the home a "lived
in" look while away.
REPEAT SCHEDULE: 7 day programming.
VARIABLE TIMING:
460D, 454D, 455D: Manual Daylight Savings
adjustment. Random mode for lived-in look. Manual
Override ON/OFF.
457Z: Turns ON at Sunset; turns OFF at Sunrise or
other times; automatic DST adjustment; Random Mode
for lived-in look; Manual Override ON/OFF.
BACKUP: Battery back-up.
ENERGY SAVINGS: Works with CFLs and LED lamps.
ACCURACY: Digital accuracy to 1 minute.
454D
455D
457Z
460D
CATALOG
NO. UPC
CODE RATINGS NO. OF
OUTLETS
( )
TYPE OF
PLUG DESCRIPTION VARIABLE TIMING
SEGMENTS
460D 16017 120VAC, 15A, 1800W General Purpose
120VAC, 15A, 1800W Resistive
120VAC, 1000W Tungsten
120VAC,
1
3
HP, TV-5
1 Polarized Daily Programmable Digital Timer 24 ON/OFFs
Different schedule for
each day of the week.
Multiple ON/OFFs
454D 16009 1 Grounded Daily Programmable Digital Timer
455D 16015 2 Grounded Daily Programmable Digital Timer
457Z 16016
120VAC, 15A, 1800W General Purpose
120VAC, 15A, 1800W Resistive
120VAC, 960W Tungsten
120VAC,
1
3
HP TV-5
2 Grounded Ultimate Plug-In 2-Outlet Timer
20 ON/OFFs
Different schedule for
each day of the week.
ON at Sunset
OFF at Sunrise
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
400D SERIES
INDOOR GENERAL
PURPOSE 1800W
DIGITAL PROGRAMMABLE
ON/OFF TIMERS
NEW!
NOTE: " " = Indicates outlet location.
APPLICATIONS
FEATURES
ORDERING INFO
TORK 121
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
PLUG-IN TIMERS
600A SERIES
OUTDOOR GENERAL PURPOSE 1875W
MECHANICAL PLUG-IN
PHOTOCELL COUNTDOWN
TIMERS
Landscape or Christmas lighting
Controls small pumps, fountains, motors
REPEAT SCHEDULE: Daily.
VARIABLE TIMING: Multiple ON/OFFs, Manual ON/
TIMER switch.
PHOTO TIMER: Two styles
652A - Dial setting. ON at dusk and OFF 2, 4, 6, or 8 hours
later. 654A - Digital setting. ON dusk and OFF 1 to 9 hours
later or at random times.
ENERGY SAVINGS: Works with CFLs and LED lamps.
602A
601A
652A
654A
611A
CATALOG
NO. UPC
CODE RATINGS NO. OF
OUTLETS
( )
TYPE OF
PLUG DESCRIPTION VARIABLE TIMING
SEGMENTS
601A 16020 125 VAC, 15A, 1875W General Purpose
125VAC, 15A, 1875W Resistive
125VAC, 10A, 1250W Tungsten
125VAC,
1
2
HP
1 Grounded Mechanical Outdoor Timer, with18" cord 15 minutes
Multiple ON/OFFs
602A 16021 2 Grounded Mechanical Outdoor Timer, with18" cord 15 minutes
Multiple ON/OFFs
611A* 16022 1 Grounded Wall Mountable
Mechanical Outdoor Timer, with 24" cord 15 minutes
Multiple ON/OFFs
652A 16026 125VAC, 15A, 1875W General Purpose
125VAC, 15A, 1875W Resistive
125VAc, 625W Tungsten
125VAC,
1
3
HP, TV-5
2 Grounded Photocell Outdoor Timer with 6.5" cord Photo ON
Dawn or timed OFF
654A 16025 2 Grounded Photocell Outdoor Timer with 6.5" cord Photo ON
Dawn or timed OFF
*611A:
1
3
HP
NOTE: " " = Indicates outlet location.
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
APPLICATIONS
FEATURES
ORDERING INFO
TORK 122
655D
CATALOG
NO. UPC
CODE RATINGS NO. OF
OUTLETS
( )
TYPE OF
PLUG DESCRIPTION VARIABLE TIMING
SEGMENTS
611D 16018 125 VAC, 15A, 1875W General Purpose
125VAC, 15A, 1875W Resistive
125VAC, 1000W Tungsten
125VAC, 8A Ballast
125VAC,
1
2
HP
1 Grounded Wall Mountable Photocell & 7 Day
Digital 2-in-1 Timer, with 24" cord Photo ON
Dawn or timed OFF
621D 16056 2 Grounded Wall Mountable, 7 Day
Digital Timer, with 18" cord Multiple ON/OFFs for
each day of the week
631D 16027 2 Grounded Wall Mountable Photocell & 7 Day
Digital 2-in-1 Timer, with 18" cord Photo ON
Dawn or timed OFF
655D* 16042 125VAC, 5A, 625W Resistive
125VAC, 600W Tungsten 2 Grounded Remote control
indoor/outdoor receiver Handheld remote ON/OFF
Landscape and Christmas lighting
Control small pumps, fountains,
motors, etc.
Energy saving
600D SERIES
OUTDOOR
GENERAL PURPOSE 1875W
7 DAY DIGITIAL WITH
PHOTOCELL, 7 DAY DIGITAL
OUTDOOR TIMERS
REPEAT SCHEDULE: 7 day programming.
VARIABLE TIMING: Manual Daylight Savings
adjustment. Random mode for lived-in look.
Manual ON/TIMER switch. Multiple ON/OFF for
each day of the week.
BACKUP: Battery back-up.
ACCURACY: Digital accuracy to 1 minute.
PHOTOCELL: 611D and 631D have built-in
photocell to always turn ON at dusk and OFF at
dawn. Add a time OFF schedule
WIRELESS REMOTE: 655D receives ON/OFF
signal up to 80 feet away.
611D
621D & 631D
(621D without photocell)
Photocell
655D
Remote
included
NEW!
NOTE: " " = Indicates outlet location.
* ETL listed for U.S. and Canada.
APPLICATIONS
FEATURES
TORK 123
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
PLUG-IN TIMERS
ORDERING INFO
800 SERIES
OUTDOOR GENERAL
PURPOSE 1875W
MECHANICAL & DIGITAL
STAKE TIMERS
Landscape and Christmas lighting
Other outdoor lighting
Energy saving
REPEAT SCHEDULE: Mechanical timer 24 hours. Digital
timer 7 day programming.
MECHANICAL TIMING: Multiple ON/OFFs, Manual ON/
TIMER switch.
DIGITAL TIMING: Manual ON/TIMER switch. Multiple
ON/OFF for each day of the week.
PHOTOCELL: 806D has optional built-in photocell to
always turn ON at dusk and OFF at dawn or 1 to 12 hours
later.
ENERGY SAVINGS: Works with CFLs and LED lamps.
CATALOG
NO. UPC
CODE RATINGS NO. OF
OUTLETS
( )
TYPE OF
PLUG DESCRIPTION VARIABLE TIMING
SEGMENTS
803B 16057 125VAC, 15A, 1875W Resistive
125VAC, 10A, 1250W Tungsten
3 Grounded Mechanical Outdoor Stake Timer,
with 2' cord 15 minutes
Multiple ON/OFFs
806B 16037 6 Grounded Mechanical Outdoor Stake Timer,
with 2' cord. 3 timed outlets and 3 untimed. 15 minutes
Multiple ON/OFFs
806D 16038 125VAC, 15A, 1875W Resistive 6 Grounded Digital Outdoor Stake Timer, with 6' cord. 3
timed outlets and 3 untimed.
Multiple ON/OFFs for each
day of the week or Photo
ON and Dawn or 1-12
hours OFF.
NEW!
803B
806B
806D
NOTE: " " = Indicates outlet location.
TORK 124
TORKALERT
TORK 127
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
APPLICATIONS
FEATURES
ORDERING INFO
TORK ALERT
TORK 127
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
TORK ALERT
MECHANICAL
STROBE HORNS
CATALOG
NO. UPC
CODE INPUT
VOLTAGE
INPUT
CURRENT
(AMPS)
dB
@10 FEET CANDELA
TA880-N5 96015 120VAC 0.115 96 15
TA5508H-G1 96071 24VDC .059 strobe only 15/75
High performance for industrial
signaling applications. Offers high
sound output, low current draw and
dependable operation. Strobes use
xenon flashtube, ideal for maximum
efficiency and reliability.
ALARM: Penetrating mechanical sound.
WIRING: Low current draw.
MOUNTING: 4" square surface mounting.
NOTE: TA880-N5 For outdoor use, unit must be mounted in a TA-WBBF outdoor backbox. See page 138
for ordering. TA5508H-G1 for indoor mounting only.
APPLICATIONS
MECHANICAL
HORNS
Loud tone with typical decibel
output of 103 dB. Low frequency
resonation for strong penetration
of noisy areas like boiler rooms,
water pumping stations, elevators
and air compressor rooms.
FEATURES
ORDERING INFO
CATALOG
NO. UPC
CODE INPUT
VOLTAGE INPUT CURRENT
(AMPS)
SURFACE TYPE
TA874-N5 96023 120VAC, 60Hz 0.070
TA874-N5R
(Red) 97613 120VAC, 60Hz 0.070
TA875-G1 97687 24VDC 0.035
WITH WEATHERPROOF BACKBOX TA-WBBF UL LISTED FOR OUTDOOR USE
TA876-N5 96026 120VAC, 60Hz 0.070
INPUT VOLTAGE: Wide input voltage
ratings for compatibility with unregulated
power supplies.
WIRING: Screw terminals for convenient
IN/OUT wiring. Low current draw for
minimizing power supply and wiring cost.
HOUSING: Steel, painted Dawn Mist.
Resonant grill design for high sound
output.
MOUNTING: To indoor box TA-BBSF
or outdoor box TA-WBBF, see accessories
page 13*.
TA880-N5
TA5508H-G1
NOTE: Use TORK signal timers for 24 hour or 7 day scheduling, see page 85.
TORK 128TORK 128TORK 128
TERMINAL SIZE: #12 - 22 AWG.
WIRING: Screw terminals permit fast IN/OUT
field wiring.
HOUSING: Steel gong and cast aluminum. See
page 138 for dimensional drawings.
APPLICATIONS
FEATURES
ORDERING INFO
CATALOG
NO. UPC
CODE SHELL
SIZE VOLTAGE INPUT
CURRENT
(AMPS)
dB
@ 10
FEET COLOR
TA340-4G5 96001 4” 24VAC 0.320 81-90 Dawn Mist
TA340-4N5 96002 4” 120VAC 0.065 81-90 Dawn Mist
TA340-6G5 96003 6” 24VAC 0.320 81-95 Dawn Mist
TA340-6N5 96004 6” 120VAC 0.065 81-95 Dawn Mist
TA340-10G5 96005 10” 24VAC 0.320 84-98 Dawn Mist
TA434-4N5 98005 4" 120VAC 0.065 81-95 Red
TA434-6N5 97521 6” 120VAC 0.065 81-95 Red
TA434-10N5 96522 10” 120VAC 0.065 84-98 Red
For indoor or outdoor applications.
High sound output, durable and
dependable performance. Ideal for
schools and hopsitals.
APPLICATIONS
MULTI-TONE
ELECTRONIC
HORNS
24VDC &115VAC
For indoor and outdoor use.
Superior sound penetration for
various room conditions. Screw
terminals accept #12AWG.
TA875-1G1
TA-MTS
HEAVY DUTY
BELLS
4", 6", 10" DIAMETERS
AC VIBRATING BELLS
ALARM SOUNDS
TA875-1G1 24VDC HORN
ALARM
TONE CURRENT
(AMPS) TYPICAL dB
@10 FEET
BELL 0.020 91
HI-LO 0.025 96
CHIME 0.028 93
SINGLE STROKE BELL 0.026 93
HORN 0.023 97
3 BEEPS, PAUSE 0.023 97
SIREN 0.040 95
SLOW WHOOP 0.040 96
TA-MTS 115VAC HORN
ALARM
TONE
AMPS @ 120VAC TYPICAL dB @10 FEET
HIGH STANDARD HIGH
OUTPUT STANDARD
OUTPUT
HORN 0.050 0.042 85 82
BELL 0.041 0.039 82 75
HORN 2 0.050 0.040 85 79
CODE 3 HORN 0.050 0.042 82 75
CODE 3 TONE 0.042 0.040 79 75
SLOW WHOOP 0.050 0.042 85 82
SIREN 0.045 0.041 85 82
HI-LO 0.042 0.039 82 79
OPERATING TEMPERATURE:
TA-MTS: -31˚F to +150˚F (-35˚C to +66˚C).
DIMENSIONS AND MOUNTING:
TA-MTS: 4
1
18
”H x 4
1
8
”W x 3
17
32
”D
Can be mounted on celing or wall.
TA875-1G1: 4
3
4
”H x 4
3
4
”W x 1
3
8
”D
1 gang, 2 gang or 4" square backbox.
FEATURES
ORDERING INFO
CATALOG
NO. UPC
CODE INPUT
VOLTAGE DESCRIPTION
TA875-1G1 97641 20-31VDC,
24VDC Multi-tone Electric Horn
TA-MTS 97674 115 VAC Multi-tone Electric Horn
NOTE: Use TORK signal timers for 24 hour or 7 day scheduling, see page 85.
TORK 129
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
TORK ALERT
LIGHT DUTY AND
GENERAL PURPOSE
BELLS & BUZZER
CHIMES &
CHIME KITS
APPLICATIONS
APPLICATIONS
FEATURES
FEATURES
ALARM: Bell ringing, non-adjustable sound.
DIMENSIONS FOR TA725:
3" H x 2
1
2
" W x 1" D.
MOUNTING: Fully enclosed sturdy steel bases
and covers. Base and cover snap together, no
screws required.
INPUT: 16V, 10VA, 120VAC.
ALARM: Chime.
MOUNTING: Fully enclosed sturdy steel bases.
Designed to operate on either bell
ringing transformers or batteries.
Non-adjustable sound.
Powerful and loud, pleasant sounding
push-button chimes. Ideal for homes,
apartments and offices.
ORDERING INFO
CATALOG
NO. UPC
CODE SWITCH VAC VDC AMPS dB
TA740 96228 2
1
2
” Gong 8-16 3-6 176 @ 10'
TA744 96230 4" Gong 8-16 3-6 178 @ 10'
TA725 96226 Buzzer 8-16 3-6 188 @ 3'
ORDERING INFO
CATALOG
NO. UPC
CODE DESCRIPTION DIMENSIONS
TAC212WS 96064 16VAC Chime + Push Button
clip for Stucco + 10VA
Transformer 7
3
16
”L x 4”W x 2”D
TAC212WL 96054 16VAC Chime +
2 Push-buttons +
10VA Transformer 7
1
4
”L x 4
3
4
”W x 2
1
2
”D
TAC210W 96052 16VAC Chime 7
1
4
”L x 4
3
4
”W x 2
1
2
”D
TA740
TA725
DIMENSIONS
TORK 130
APPLICATIONS
APPLICATIONS
FEATURES
FEATURES
WEATHERPROOF
MOTOR DRIVEN
SIREN
MANUAL FIRE
ALARM
PULL-DOWN STATION
ORDERING INFO
CATALOG
NO. UPC
CODE INPUT
VOLTAGE dB
@10 FEET AMPS VA
TA315-1N5 96599 120VAC/DC 117 2.5 300
ORDERING INFO
CATALOG
NO. UPC
CODE SWITCH VOLTS AMPS
TA270A 96521 SPST, NO 30V AC/DC 1
For industrial and outdoor
use. Ideal for evacuation and
warning systems.
INPUT VOLTAGE: 120AC & DC, 60Hz.
ALARM: Loud, distinctive tone. Designed
to be effective over standard horns or bells.
HOUSING: Red enamel paint over heavy
gauge aluminum housing. Fully enclosed
motor. 180° swivel and adjustable
direction.
ALARM: Loud, distinctive tone. Designed to be
compatible with any control panel to initiate local
alarm signals, trip municipal fire alarm box and start
fire pumps.
MOUNTING: Sturdy metal construction, mounts to
a standard single gang electrical box.
Designed for indoor use.
Ideal for schools, hospitals,
industrial plants, warehouses
and retail stores. Key
required to close and reset
device. Meets requirements,
BSA, MEA, CA and UL.
Junction box &
(2) wire nuts (not furnished)
Power
wires
2 feet
long 6-7/8"
8-1/4"
FRONT VIEW
Siren power wires
1/2" conduit (not furnished)
8-1/2" dia.
7-1/2" dia.
15-3/8"
Mount siren (hardware not included)
(2) nuts,
loosen to
adjust siren
direction.
1/2" conduit
connector
(2) 9/32"
mounting
holes
Junction box &
(2) wire nuts (not furnished)
Power
wires
2 feet
long 6-7/8"
8-1/4"
FRONT VIEW
Siren power wires
1/2" conduit (not furnished)
8-1/2" dia.
7-1/2" dia.
15-3/8"
Mount siren (hardware not included)
(2) nuts,
loosen to
adjust siren
direction.
1/2" conduit
connector
(2) 9/32"
mounting
holes
APPLICATIONS
TELEPHONE
STROBE
For single-line analog phone
lines. Emits a high intesity
flashing light when the telephone
rings. Ideal for alerting the
hearing impaired, high ambient
noise environments and quiet
zones. ADA compliant.
TORK 131
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
TORK ALERT
FEATURES
PLUG:
RJ-11C connection.
TA-B-KHD-120VAC, includes 120VAC
power cord.
MOUNTING: Easily mounts to interior
surfaces, for indoor use.
ORDERING INFO
CATALOG
NO. UPC
CODE INPUT TELEPHONE
RING VOLTAGE POWER RINGER
EQUIVALENCE PEAK
CANDLEPOWER
TA-B-KHD-120VAC 97101 45-130V, 20-30Hz 120VAC 0.4 70,000
TA-B-KHD-1000-PP 97102 50-130V, 20-30HzAnalog line
ring voltage 1.5 8,000
TELEPHONE
RELAY
APPLICATIONS
APPLICATIONS
FEATURES
FEATURES
INPUT: Accepts RJ-11C phone plug.
WIRING: Hard wire connections,
for analog phone lines.
MOUNTING: Weatherproof, indoor and
outdoor, includes mounting bracket.
QUARTZ
Accurate to one minute per year. Low power
consumption for long battery life.
Uses AA battery (not supplied).
ELECTRIC
110VAC, 60 Hz synchronous motor. 66 inch line
cord and plug. Does not require grounding.
MOUNTING: Concealed mounting brackets allow
for simple, neat placement on walls.
This device activates appliances
when a telephone ring voltage is
detected. For indoor and outdoor
use with horns, bells or strobes.
Recommended use where
ambient noise levels are high.
FCC approved.
Each model meets United States
Government Specifications. All
Clocks provide second hand for
accurate timing.
TORK 132
WALL CLOCKS
QUARTZ & ELECTRIC
ORDERING INFO
ORDERING INFO
CATALOG
NO. UPC
CODE INPUT TELEPHONE
RING VOLTAGE AC INPUT
VOLTAGE RINGER
EQUIVALENCE PEAK
CANDLEPOWER
TA-B-8332 97100 39-150V/20-30Hz 115VAC-5A,
230VAC-2A Up to
115VDC-500MA 0.6
QUARTZ CLOCK
CATALOG
NO. UPC
CODE TYPE SIZE FRAME
COLOR
TA1886 G 96156 QUARTZ 8” Grey
TA1886 B 96155 QUARTZ 8” Brown
TA1887 G 96159 QUARTZ 12” Grey
TA1887 B 96157 QUARTZ 12” Brown
TA1887 BK 96158 QUARTZ 12” Black
ELECTRIC CLOCK
CATALOG
NO. UPC
CODE TYPE SIZE FRAME
COLOR
TA1880 G 96152 ELECTRIC 8” Grey
TA1880 B 96151 ELECTRIC 8” Brown
TA1882 G 96154 ELECTRIC 12” Grey
TA1882 B 96153 ELECTRIC 12” Brown
ELECTRIC DOOR
OPENERS
REMOTE CONTROL
& CONTACT DEVICES
TORK 133
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
TORK ALERT
APPLICATIONS
For unlocking or locking metal or
wooden doors using low voltage
wiring. For AC, use TA591 or
TA592 transformer.
Reversible for right or left hand door. Use with mortise entrance locks having a latch
bolt with up to
1
2
" width and throw. Dimensional drawings available on page 138.
For activating a variety of signals, ideal for limiting space applications. Self-insulating and can be
mounted in any direction. All units include companion magnet. Dimensions: 2
3
16
”L x
1
2
”W x
1
2
”D
Signals automatically with the opening and closing of doors, windows and transoms. Operates from
pressure in any direction. Non-tilt, non-jamming design. Fits
3
4
" hole; no need to mortise.
Reversible for right or left hand door. Standard surface type used with lock latches with
up to
5
8
" width and throw. 6" wire leads. Dimensional drawings available on page 138.
Signals automatically as door is openend. Commonly used on store doors to announce
entrance of customers. Mounts on top of door frame. Solid cast brass. Size: 3 x 1
5
8
DEVICE CATALOG
NO. UPC
CODE VOLTS AMPS
TA09 96960 8-16VAC
3-6VDC .95-1.75
1.25-1.80
TA154 96962 16VAC
3-6VDC .95-1.75
1.25-1.80
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION VOLTS AMPS
MAX.
TA60 96975 Circuit closed with
magnet engaged
24VAC
12VDC .5TA61 96976 Make & break
NO and NC
TA62 96977 Circuit open with
magnet engaged
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION VOLTS AMPS
MAX.
TA44 96995 Normally closed
Push to open
12-24V
AC/DC 2TA45 96996 Normally open
Push to close
TA46 96997 Momentary contact
Push to make & break
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION VOLTS AMPS
MAX.
TA502 96964 Light ON when
door is open 125VAC
250VAC 6
3
TA503 96965 Light OFF when
door is open 125VAC
250VAC 6
3
DEVICE CATALOG
NO. UPC
CODE VOLTS
TA152 96961 8-16VAC, 3-6VDC
DEVICE CATALOG
NO. UPC
CODE VOLTS AMPS
MAX.
TA236 96963 12-24VAC 2
MORTISE TYPE REMOTE OPENER
MAGNETIC SWITCH CONTACTS
DOOR/WINDOW CONTACTS, ROLLING BALL TYPE
ELECTRIC DOOR SWITCH
RIM TYPE REMOTE OPENER
DOOR TRIP SWITCH
For turning lights/signals on or off when doors are opened or closed. Ideal for closets, dark rooms,
storage areas of walk-in refrigeration. Rust resistant steel case with 4 knockouts, antique brass plate.
Box dimensions: 1
1
4"
W x 3
7
8"
H x 2”D. Plate dimensions: 1
1
4
”W
DIMENSIONS
PUSH-BUTTONS
ILLUMINATED,
NON-ILLUMINATED &
WEATHERPROOF
TORK 134
BUTTON CATALOG
NO. UPC
CODE COLOR SIZE
TA603L 96035 Gold 1
3
4
"
(diameter)
TA631L 96089 White 2
3
4
x
7
8"
TA656B 96039 Gold
15
16
x 2
3
4
TA215LB 96031 Brass 1
1
4
x 2”
TA620L* 96037 Chrome
5
8
"
(diameter)
TA620LB* 96038 Brass
5
8
"
(diameter)
BUTTON CATALOG
NO. UPC
CODE COLOR SIZE
TA600 96041 Polished
Brass 2
1
4
(diameter)
TA603 96044 Polished
Brass 1
3
4
(diameter)
TA631 96088 White 2
3
4
x
7
8
"
TA635 96047 Ivory, black bar 2
3
4
x
7
8
"
TA666BK 96048 Black, ivory bar 2
3
4
X 2
3
4
TA602 96043 Polished Brass 1
3
8
x 5
1
4
TA601 96042 Sprayed Brass 2 x 2
9
16
TA620* 96045 Chrome
5
8
(diameter)
TA620B* 96046 Brass
5
8
(diameter)
BUTTON CATALOG
NO. UPC
CODE DESCRIPTION INPUT
VOLTAGE
TA1786B 96090 Without conduit
backplate Momentary Contacts
4 amps AC/DC @ 12V
4 amps AC, 2 amps DC @ 24V
2 amps AC
1 amp DC @48V
TA1786CB 96091 With conduit
backplate
ILLUMINATED PUSH-BUTTONS, UP TO 16VAC NON-ILLUMINATED PUSH-BUTTONS, UP TO 24VAC
WEATHERPROOF PUSH-BUTTONS / SOLID CAST BRASS
APPLICATIONS
For outdoor use to activate low
voltage bells, buzzers, horns or any
other audible signal. Ideal for factory
doors, receiving departments, small
office buildings, limited access retail
stores and private homes.
*Stainless steel plate to fit TA620 models: Order TA 147-1
1 3/8"
(34mm)
2 13/32"
(61mm)
MODEL TA1786CB MODEL TA1786B
1 3/16"
(30mm)
2 13/32"
(61mm)
C
L
2-3/8" DIA.
MOUNTING HOLES
ON MODEL TA1786B and TA1786CB
1-13/16"
BETWEEN
TA1786B ONLY
TORK 135
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
TORK ALERT
WARNING LIGHTS
INDUSTRIAL UNITS
APPLICATIONS
1
2
" conduit mounting. Full
selection of dome colors,
see "Ordering Info". For
outdoor use. All units must be
mounted vertically with base
at bottom.
Light intensifying reflector rotates arounf a low current 25 watt bulb. Bayonet socket for
easy lamp replacement. Ideal for restricted or dangerous areas.
Heavy Duty, double sealed beam, revolving light with 30 watt lamps. Each 35,000 CP bulb
provides long range visibility.
High intensity strobe tube with inner fluted lens for maximum brilliance. No moving parts makes
it immune to shock and vibration. Ideal for security alert.
Large parabolic reflector rotates around a 100 wall bulb. Long range beam. Use to indicate
equipment malfunctions, security intrusion, etc.
Solid state circuitry in a low profile design. No moving parts means less Maintenance!
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION VOLTS AMPS
TA52RN5 96063 80-90 FPM
360˚ rotation
Dependable belt & turntable design
Acrylic dome
Nominal current draw
6
1
2
”H x 5
5
8
” diameter
TA52AN5 96163 117VAC .21
TA52BN5 96263
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION VOLTS AMPS
TA371LRN5 96500 80-90 FPM
Lexan® dome
Quiet belt drive motor
Anodized aluminum housing with polished
aluminum, non-tarnishing base
Snap lock retaining ring
for quick & economical changeout
9
1
2
”H x 8
1
2
” diameter
117 VAC .8
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION VOLTS AMPS
TA94RN5 97626 70-80 FPM
Solid state electronic circuitry High
output 3-4 watt, 3.6 joules
Acrylic dome
Glass filled polypropylene housing
Suitable for outdoor use
9
1
2
”H x 8
1
2
” diameter
TA94AN5 97627 117VAC .04
TA94BN5 97628
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION VOLTS AMPS
TA47RN5 96061 90 FPM
Corrosion resistant/Outdoor use
Glass filled polypropylene housing
Acrylic dome
Tamper resistant dome clamps
Nominal current draw
9
1
2
"H x 8
1
2
” diameter
117VAC
TA47AN5 96161 117VAC .9
TA47AR5 96162 240VAC,
60Hz
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION VOLTS AMPS
TA93-2RN5 99622 70-80 FPM
Solid state electronic circuitry
High output 3-4 watt, 3.6 joules
Vertically mounted flash tube
Snap out socket base for
360˚ Fresnel dome optics
Nominal current draw
6
1
2
”H x 5
1
8
” diameter
117VAC .04
TA93-2AN5 97623
TA93-2CN5 96968
TA93-2BN5 97624
TA52*N5 – COMPACT ROTATING BEACON
TA371L*N5 – ROTATING SEALED TWIN BEAMS
TA94*N5 – ELECTRONIC STROBE
TA47*N5 / TA47*R5 – ALL PURPOSE 360° BEACON
TA93-2*N5 – MIDI-STROBE
ORDERING INFO
COLOR LETTER TO
REPLACE "*"
Red R
Amber A
Clear C
Blue B
For replacement parts and accessories, see page 138.
TORK 136
APPLICATIONS
1
2
" conduit mounting. Full
selection of dome colors,
see "Ordering Info". For
outdoor use. All units must be
mounted vertically with base
at bottom.
Single point shock-mounting. Ideal for use on security or service vehicles. Single point shock-mounting. Ideal for use on security or service vehicles.
Solid state electronic unit. Helps to comply with OSHA and State regulations. Makes
distinctive noise, ideal for extreme variations in background noise
Ideal for industrial applications requiring extremely high visibility. One model
covers all popular mounting methods:
1
2
" pipe, surface, flange, electrical box.
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION VOLTS
TA53RE1 96083
90-100 FPM
Dependable belt & turntable design
25 watt lamp
Acrylic Dome
Nominal current draw
7
1
2
”H x 6” diameter
12VDC
TA53AE1 96183
TA53AF1 96185 36VDC
TA53AG1 96184 24VDC
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION VOLTS
TA54AE1 96187 75 FPM, 12 watt lamp
Quiet belt-drive motor.
Teardrop design fits under windshields.
Includes glare shield, velcro tape
4
1
2
”H x 7
1
2
” diameter
12VDC
TA54RE1 96087
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION VOLTS
TA879 96102
2 sound levels
97 or 87 dB +/- dB at 4ft
Multi-voltage
Water-resistant housing
12 to
48VDC
DEVICE CATALOG
NO. UPC
CODE DESCRIPTION VOLTS AMPS
TA131DRN5 96510
60 FPM, 7.5 JPF
High intensity 85,000 peak CP
Flashtube Rated at 7000-8000 hrs.
Durable Lexan® housing
5”H x 7
1
4
” diameter
120VAC .2
TA131DAN5 96610
TA131DRU1 96511 10.5-
31.0VDC
TA131DAU1 97611
TA53*E1 – ROTATING BEACON TA54*E1 – PORTABLE, MAGNETIC, ROTATING BEACON
TA879 – VEHICULAR BACKUP ALARM
TA131D*N5 / TA131D*U1 – DOUBLE FLASH SUPER STROBE
NOTE: "FPM" = Flashes per minute
"JPF" = Joules per flash
WARNING LIGHTS
VEHICULAR UNITS ORDERING INFO
COLOR LETTER TO
REPLACE "*"
Red R
Amber A
APPLICATIONS
APPLICATIONS
POWER SUPPLY
UNITS
24 VDC UNITS
TRANSFORMERS
Units provide power to
multiple signaling devices
depending on requirements.
Engineered to ensure long
use on bells, buzzers and
chimes.
TA640
TA606
ORDERING INFO
ORDERING INFO
CATALOG
NO. UPC
CODE INPUT
VOLTAGE OUTPUT
VOLTAGE OUTPUT
CURRENT REGULATION RIPPLE
VOLTAGE
TA606 96109 117VAC 24VDC 600mA
TA640 96110 115VAC 24VDC 4A +/-5% 10mVRMS
CATALOG
NO. UPC
CODE TYPE VOLTS-AMPS
(VA) PRIMARY
VOLTAGE SECONDARY
VOLTAGE Hz
TA590 96104 Bell 5120 10 60
TA591 96105 Chime 10 120 16 60
TA592 96106 Tri-Volt 10-10-20 120 8-16-24 50/60
TA598 96602 Tri-Volt 20-30-30 120 8-16-24 60
TA599 96108 Heavy Duty 40 120 24 60
TA1245Y-50 96166 Heavy Duty 50VA 120/208/240 24 60
TA1245Y-75 96167 Heavy Duty 75VA 120/208/240 24 60
FEATURES
TA606
Regulated and filtered 24VDC up to 600mA. Easy to
use screw terminals, accepts #16-24AWG. No conduit is
required for installation.
TA640
Dual output unit, each providing 2 Amps fo current. If
connected in parallel, will provide up to 4Amps. Circuit
breaker provides input protection.
TORK 137
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
TORK ALERT
WIRING DIAGRAMS
TORK 138
ACCESSORIES,
REPLACEMENT
PARTS
& DIMENSIONS
ORDERING INFO
UNIT CATALOG
NO. UPC
CODE DESCRIPTION
TA131D TA-D8A 96971 Acrylic Dome – Amber
TA53 TA-M1 96138 12VDC Motor
TA53, TA54 TA-B1 96114 Small Drive Belts
TA53, TA54 TA-B2 96115 Large Drive Belts
TA371L TA-B3 96116 Drive Belts
TA53, TA54 TA-L3 96129 12VDC Bulb
TA53 TA-L4 96130 24VDC Bulb
TA93-2 TA-L6-2 96982 110VAC Xenon Flash Tube
TA52 TA-L8 96134 110VAC Bulb
TA47 TA-L9 96135 110VAC Bulb
TA94 TA-L10 96136 110VAC Xenon Flash Tube
TA-94 TA-L10-1 96981 110VAC Xenon Flash Tube
TA371L TA-L12 97625 110VAC Bulb
TA502 TA502-BX 96967 Backbox
TA502 TA502SW 96966 Replacement switch
TA503 TA503SW 96969 Replacement switcH
TA874 Series TA-BBSF 97694 Backbox – 4" painted Dawn Mist
TA874 Series TA-WBBF 97692 Weatherproof Backbox – .5" KOs
4" painted Dawn Mist
TA-BBSF, TA-WBBF TA-SFPF 97707 Semi-Flush plate – Dawn Mist
TA-BBSF, TA-WBBF TA-SFPFR 97697 Semi-Flush plate – Red
TA47, TA94 TA-ADR 96111 Acrylic Dome – Red
TA47, TA94 TA-ADA 96311 Acrylic Dome – Amber
TA47, TA94 TA-ADB 96411 Acrylic Dome – Blue
TA52, TA53 TA-D5B 96419 Acrylic Dome – Blue
TA54 TA-D6R 96120 Dome – Red
TA54 TA-D6A 96320 Dome – Amber
TA54 TA-D6C 96422 Dome – Clear
TA93, TA94 TA-D7R 96121 Fresnal Dome – Red
TA93, TA94 TA-D7A 96321 Fresnal Dome – Amber
TA93, TA94 TA-D7C 96621 Fresnal Dome – Clear
TA93, TA94 TA-D7B 96421 Fresnal Dome – Blue
TA131D TA-D8R 96970 Acrylic Dome – Red
COLOR LETTER TO
REPLACE "*"
Red R
Amber A
Clear C
Blue B
Green G
White W
< Full selection of dome colors.
To designate color, place desired
letter in place of " * "
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
3-1/4"
6"
3-3/8"
3-3/8"
4-1/16"
4-1/16"
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
3-1/4"
10" DIA.
3-3/8"
3-3/8"
4-1/16"
4-1/16"
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
2-7/8"
4-1/16"
3-3/8"
3-3/8"
4 1/16”
10”
REMOTE CONTROL DOOR OPENERS
2-1/8"
9/16" 3-5/16" WIRE
LEADS
No. 6 MOUNTING
SCREWS (3)
1-3/16"
C
L
C
L
1-3/8"
2-3/4" 11/32"
1/16"
1/8"
1/16"
11/16" 9/16"
1/2"
3/4"
3/8"
TA152
1-9/16"
5/8" 1"
3-5/8"
1-1/4"
1/8"
15/16"
1/2"
7/32"
7/16" 3/32"
15/16"
1/4"
5-3/8"
5-7/8"
5/8"
1-1/4"
C
L
3/32" 1-3/4"
1-3/8"
NO. 8 FLAT HEAD
WOOD SCREW
TA09
3" 3-1/2"
1-13/16"
No. 6 FLAT HEAD
WOOD SCREW
WIRE
LEADS
1-3/8"
11/16"
C
L
1-9/16"
2-7/8"
27/32" 23/32"
15/16"
7/16"
3/16"
3/32"
5/8"
C
L
TA154
HEAVY DUTY BELLS
DIMENSIONS
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
3-1/4"
6"
3-3/8"
3-3/8"
4-1/16"
4-1/16"
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
3-1/4"
10" DIA.
3-3/8"
3-3/8"
4-1/16"
4-1/16"
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
2-7/8"
4-1/16"
3-3/8"
3-3/8"
4 1/16”
6”
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
3-1/4"
6"
3-3/8"
3-3/8"
4-1/16"
4-1/16"
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
3-1/4"
10" DIA.
3-3/8"
3-3/8"
4-1/16"
4-1/16"
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
2-7/8"
4-1/16"
3-3/8"
3-3/8"
4 1/16”
4”
POOL&SPA CONTROLS
NOTE: " " = Indicates freeze protection.
REVERSIBLE DOOR: Easy-Hinge patented
removable and reversible door. Change from
left to right opening. Solves installation issues
in the field.
WHILE-IN-USE COMPARTMENT: Inside
mounting for two devices with cord exit.
DEVICE MOUNTING: Provision for
mounting one or two devices in any
combination accepts toggle, GFCI, X-10 and
UPB type devices in, PP-100R and PP-125R
enclosures.
TRANSFORMER: Select panels include 120V
input: 100 watt with output 12V/13V or 300
watt with output 12V/13V/14V.
COMPACT 2-IN-1: PP-20R-2P1 and
PP-20R-2P4 includes two timers in a compact
housing. Interlock switch allows second timer
to turn ON only if first timer is in operation.
ENCLOSURE: Metal NEMA 3R with lockable
hasp. See page 153 for dimensions.
APPLICATIONS
TORK 141
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
POOL & SPA
CONTROLS
APPLICATIONS
FEATURES
Pumps
Swimming pools
Fountains
Ponds
COMBINATION PANEL: The PP panel
series provides a flexible platform to create a
custom pool and spa control at an off the shelf
price. Start with a blank panel and addtimers,
freeze controls, circuit breakers, switches and
outlets for a custom installation. Or select a
pre-assembled timer/panel available in many
popular combinations.
PP-10R: 15 amp timed GFCI protected outlet
with additional GFCI outlet.
PP-20R: 20 amp load center 120-240V, 1/2
circuit breaker base.
PP-100R: 100 amp load center 120-240V,
5/10 circuit breaker base.
PP-125R: 125 amp load center 120-240V,
8/16 circuit breaker base.
CONTROLS: Freeze protection or mechanical
and digital timers are all available with unique
features not found elsewhere in the industry.
Find specification details on pages 147 and 148.
BREAKERS: Listed for Cutler Hammer (BR),
GE (THQL), Murray/Siemens (MP) and Square D
(HOM) (not included).
PP PANEL SERIES
POOL AND SPA PANELS
WITH TIME SWTICHES
LISTED
POOL/SPA
CONTROL PANEL
3NZM
PP-20R-P4
PP-20R-2P4
PP-10R-M-GFCI
ORDERING INFO
CATALOG
NO.
UPC
CODE CONTROL #1 CONTROL
INPUT CONTROL #2 CONTROL
INPUT
ADDITIONAL
INFORMATION
PP-10R-M-GFCI 53010 Mechanical
24 hour timer 120VAC N/A Rated for 15A,
1
2
HP @ 120VAC
PP-10R-E-GFCI 53011 Digital
7 day timer 120VAC N/A Rated for 15A,
1
2
HP @ 120VAC
PP-20R 94015 N/A 120/240VAC N/A Panel only. Add controls from
page 147 and 148.
PP-20R-P1 53000 P1101-M 120VAC N/A
PP-20R-P4 53001 P1104-M 240VAC N/A
PP-20R-2P1 53002 P1101-2M 120VAC Included with control
#1 mechanism 120VAC Two timers design 50A panel
PP-20R-2P4 53003 P1104-2M 240 VAC Included with control
#1 mechanism 240VAC Two timers design 60A panel
PP-100R 94016 N/A 120/240VAC Panel only. Add controls from
page 147 and 148.
PP-100R-P4 53004 P1104-M 240VAC Add another control
from page 147 and 148.
PP-100R-P4P1 53005 P1104-M 240VAC P1101-M 120VAC
PP-100R-2P4 53006 P1104-M 240VAC P1104-M 240VAC
PP-100R-P4P4FM 53009 P1104-M 240VAC P1104FM-M 240VAC Timer 2 includes
Fireman Switch
PP-125R 94017 N/A 120/240VAC Panel only. Add controls
from page 147 and 148.
PP-125R-P4 53007 P1104-M 240VAC Add another control from
page 147 and 148.
PP-125-2P4 53008 P1104-M 240VAC P1104-M 240VAC
PP-125R-P4-100X 94018 P1104-M 240VAC Includes 100 watt
Low Voltage Transformer
PP-125R-P4-300X 94019 P1104-M 240VAC Includes 300 watt
Low Voltage Transformer
PP-100R-P4 PP-125R-P4 PP-125R-P4-100X
TORK 142
NOTE: " " = Indicates Freeze Protection.
APPLICATIONS
ORDERING INFO
TORK 143
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
POOL & SPA
CONTROLS
APPLICATIONS
FEATURES
Pumps
Swimming pools
Fountains
Ponds
FREEZE PROTECTION ONLY: Sensor turns on
load when outdoor air temperature drops to user
settable level between 33°F to 42°F. Moving
water prevents costly freeze damage.
TIMERS WITH FREEZE PROTECTION:
Control loads with mechanical or digital timer
with regular on and off schedule. Built-in
temperature sensor forces load on if outdoor air
temperature drops to user settable level between
33°F to 42°F.
COMBINATION PANEL
Combination of timers, freeze protection,
breaker base, and device mountings.
PP-20R: 20 amp load center 120-240V,
1
2
circuit breaker base.
PP-100R: 100 amp load center 120-240V,
5
10
circuit breaker base.
BEAKERS: Listed for Cutler Hammer (BR), GE
(THQL), Murray/Siemens (MP) and Square D
(HOM) (not included).
WHILE-IN-USE COMPARTMENT: Inside
mounting for two devices with cord exit.
DEVICE MOUNTING: Provision for mounting
one or two devices in any combination accepts
toggle, GFCI, X-10 and UPB type devices.
PFP SERIES
POOL FREEZE PROTECTION
SWIMMING POOL
TIME SWITCHES
CATALOG
NO. UPC
CODE CONTROL CONTROL
INPUT NOTES
PFP2 94035 PFP2-M 240VAC Freeze protection only
PFP3 94036 PFP3-M 120/240
w/neutral Freeze protection only
PFP1102 94037 PFP1102-M 240VAC Freeze protection
with timer
PFP1103 94038 PFP1103-M 120/240
w/neutral Freeze protection
with timer
PFPEW1102 94039 PFPEW1102-M 240VAC Freeze protection
with Digital timer
PFPEW1103 94040 PFPEW1103-M 120/240
w/neutral Freeze protection
with Digital timer
PP-20R-F2 94033 PFP1102-M 240VAC Freeze protection
with timer
PP-100R-F2F4FM 94034 PFP1102-M &
P1104FM-M 240VAC Timer 2 includes
Fireman Switch
PFPT 94028 120/240VAC Thermostat accessory
APPLICATIONS
FEATURES
ORDERING INFO
1100 SERIES
SAME ON/OFF TIMES EACH DAY
SWIMMING POOL
TIME SWITCHES
SCHEDULING: Minimum ON setting is 20 minutes with a
minimum OFF setting of 75 minutes. Dial accommodates up to
12 pairs of trippers. One pair included.
MANUAL OVERRIDE: Until the next regularly scheduled
ON or OFF automatic operation then resumes.
INPUT VOLTAGE: 120 or 208-277VAC,
60Hz (varies by model).
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE:
-40° to 165°F (-40° to +74°C).
POWER CONSUMPTION: 3 watt max.
ENCLOSURE: Lockable hasp. Type varies
by model. See page 153 for dimensions and
additional enclosure information.
Pool pumps
Heaters
Lighting
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz OUTPUT
CONTACTS ENCLOSURE
TYPE
1101 10011 120 SPST Metal Indoor
NEMA 1
1101-M-IAP 10052 120 SPST Mechanism and
mounting plate
1104 10014 208-277 DPST Metal Indoor
NEMA 1
1104-N 10042 208-277 DPST Noryl® Indoor/Outdoor
NEMA 3R
1104-O 10017 208-277 DPST Metal Indoor/Outdoor
NEMA 3
1104-M-IAP 10051 240 DPST Mechanism and
mounting plate
1101FM-N 10043 120 SPST Noryl® Indoor/Outdoor NEMA
3R with fireman switch
1104FM-N 10044 208-277 DPST Noryl® Indoor/Outdoor NEMA
3R with fireman switch
1101FM-M 10043 120 SPST Mechanism with fireman
switch
1104FM-M 10044 208-277 DPST Mechanism with fireman
switch
1101D 10028 120 Two 1101
SPST each Metal Indoor/Outdoor
NEMA 3R
1104D 10029 208-277 Two 1104
DPST each Metal Indoor/Outdoor
NEMA 3R
1104DF 10032 208-277 One 1104
One 1104FM Metal Indoor/Outdoor NEMA
3R
Replacement Trippers Order #P47 for a pair of ON/OFF trippers
Order #PF48 for a pair of ON/OFF trippers for 1100FM series
Replacement Motor #101 (120V) & #201 (208-277V)
SPECIFICATIONS
CONTACT RATINGS
TYPE VOLTAGE CONTACT
RATING
General Purpose 120-277VAC
single phase 40A
Resistive 120-277VAC
single phase 40A
Tungsten 120VAC 40A
Inductive 120, 277VAC
single phase 20A
Pilot Duty 120-277VAC 1000VA
Motor 120VAC
240VAC
2HP
5HP
TORK 144
APPLICATIONS
FEATURES
TORK 145
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
POOL & SPA
CONTROLS
APPLICATIONS
ORDERING INFO
FEATURES
Two speed pumps
TWO CHANNEL: Two programmable contacts
for independent control of pool equipment and
SVR or coordinated control for two speed pumps.
SCHEDULING: 99 ON & OFF set points allow
individual programs for each day of the week at
a minimum 1 minute apart.
HOLIDAYS: 1 to 24 individual dates for
preprogrammed longer run times for heavy use
times.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted) for year-round pools.
MANUAL OVERRIDE: Until the next regularly
scheduled ON or OFF, automatic operation then
resumes.
CLOCK FORMAT: AM/PM or Military time
POWER OUTAGE BACKUP: Permanent
schedule retention when timer is powered
down at the end of the season. Super capacitor
provides 7 days of real time backup.
DW200B TIMER
TWO SPEED PUMP CONTROL
TIME SWITCH
CATALOG
NO. UPC
CODE TIMER SUPPLY
(VAC) 60Hz NO. OF
CHANNELS DRY CONTACTS
(UNPOWERED)
DW200B 82190 120/208-240/277VAC 2 SPDT
DW200B-0 82231 120/208-240/277VAC 2 SPDT
CONTACT RATINGS
SPECIFICATIONS CONTACT RATINGS
WIRING DIAGRAMS
SPECIFICATIONS
TIMING ACCURACY: Line Frequency.
INPUT VOLTAGE:
120/208-240/277VAC, 50/60Hz.
TERMINAL RANGE: #12 - #16AWG.
OPERATING TEMPERATURE:
-40°F to 158°F (-40°C to +70°C).
POWER CONSUMPTION: 5VA max.
ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R
is standard with lockable hasp. See page 153 for
enclosure dimensions and accessories.
TYPE VOLTAGE CONTACT
RATING
NO NC
General Purpose 24-277VAC 30A 30A
Ballast 120VAC
277VAC
30A
20A
10A
10A
Tungsten 120-277VAC 15A 2A
Pilot Duty 120-277VAC 720VA 720VA
Motor Load 120VAC
208-277VAC
1HP
2HP
1HP
2HP
Resistive 28VDC 30A 30A
SPDT
N
LOAD
NO
L
CNC
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
A
ND APPLY ONLY ONE VOLTAGE
CH 1
SPDT
CH 2
SPDT
N
LOAD
NO
L
CNCNOCNC
N
LOAD
L
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DWZ100B SERIES
DW200B SERIES
TWO SPEED PUMP WIRING
SPDT
N
LOAD
NO
L
CNC
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
A
ND APPLY ONLY ONE VOLTAGE
CH 1
SPDT
CH 2
SPDT
N
LOAD
NO
L
CNCNOCNC
N
LOAD
L
TIMER SUPPLY
N120
120V
208-240V
277V
208-240 277
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DWZ100B SERIES DW200B SERIES
TWO SPEED PUMP WIRING
TORK 146
NOTE: " " = Indicates Freeze Protection.
TORK 147
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
POOL & SPA
CONTROLS
ORDERING INFO
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz CONTACTS RESISTIVE/
INDUCTIVE
RATINGS HP RATING NOTES
PFP2-M 94026 240 DPST 40A 7.5HP @ 240V Thermostat
only
PFP3-M 94027 120/240
w/neutral DPST 40A 3 HP @ 120V
7.5HP @ 240V Thermostat
only
P1101-M 10056 120 DPST 40A 3 HP @ 120V
P1101FM-M 10060 120 DPST 40A 3 HP @ 120V Fireman
Switch
PF1101-M 94020 120 DPST 40A 3 HP @ 120V Accepts PFPT
thermostat input
PF1101FM-M 94024 120 DPST 40A 3 HP @ 120V Fireman Switch & Accepts
PFPT thermostat input
PFP1102-M 94022 240 DPST 40A 7.5HP @ 240V Freeze Protection
included
PFP1103-M 94023 120/240
w/neutral DPST 40A 3 HP @ 120V
7.5HP @ 240V
Freeze Protection
included
P1104-M 10057 240 DPST 40A 7.5HP @ 240V
P1104FM-M 10061 240 DPST 40A 7.5HP @ 240V Fireman
Switch
PF1104-M 94021 240 DPST 40A 7.5HP @ 240V Accepts PFPT
thermostat input
PF1104FM-M 94025 240 DPST 40A 7.5HP @ 240V Fireman Switch & Accepts
PFPT thermostat input
P1101-2M 10058 120 DPST 40A 2HP @ 120V Replacement for
PP-20R-2P1
P1104-2M 10059 240 DPST 40A 5HP @ 240V Replacement for
PP-20R-2P4
QUICK INSTALL/RELEASE LEVER: For easy installation
and removal when installing into pool panels.
LOAD INDICATOR LAMP
CONVENIENT EXTERNAL ROCKER SWITCH: 3 position
switch: OFF/ON/AUTO. Use switch to turn OFF pump at the
end of pool season.
REAL TIME SWITCH FACE: Easy to set and check time.
CAPTIVE TRIPPERS: 15 minute intervals, no lost trippers.
HEATER CONTACTS: FM suffix includes "Fireman Switch"
to turn off pool heater 20-30 minutes before timer turns OFF.
Contact rates SPST, 15A @120V.
THERMOSTAT: PFP models include built in Freeze
Protection. No extra wiring. Thermostat turns on load at
user settable level between 33°F and 42°F. Moving water
prevents costly freeze damage.
ACCESSORY CONTACT: PF models include extra contact to
accept PFPT Freeze Protection Accessory. Thermostat turns ON
load at user settable level between 33°F adn 42°F. Moving
water prevents costly freeze damage.
TIMER INTERLOCK: Makes one second timer dependant
on operation of another timer.
P1100 SERIES
SWIMMING POOL TIMERS, 24 HOUR
ELECTROMECHANICAL
CONTROL
NOTE: " " = Indicates Freeze Protection.
P1100 SERIES
SWIMMING POOL TIMERS, 7 DAY
DIGITAL CONTROL
QUICK INSTALL/RELEASE LEVER: For easy installation
and removal when installing into pool panels.
LOAD INDICATOR LAMP
LARGE LCD DISPLAY
LARGE "MANUAL" BUTTON: 3 operating modes
available: OFF/ON/AUTO. Using the OFF mode, the pool can
be closed down without disrupting the time settings.
POWER OUTAGE BACKUP: Battery retains time and
schedule.
7 DAY PROGRAMMING ONE MINUTE INTERVAL:
Allows for the control of various electrical equipment on a 7
day schedule. 15 schedule weekly programs.
THERMOSTAT: PFPEW models include built in Freeze
Protection. No extra wiring. Thermostat turns on load at
user settable level between 33°F and 42°F. Moving water
prevents costly freeze damage.
ACCESSORY CONTACT: PFEW models include extra
contact to accept PFPT Freeze Protection Accessory.
Thermostat turns ON load at user settable level between 33°F
and 42°F. Moving water prevents costly freeze damage.
TIMER INTERLOCK: Makes one timer dependant on
operation of another timer.
ORDERING INFO
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz CONTACTS RESISTIVE/
INDUCTIVE
RATINGS HP RATING NOTES
PEW101-M 82432 120 DPST 40A 3 HP @ 120
PFEW101-M 94029 120 DPST 40A 3 HP @ 120 Accepts PFPT
thermostat input
PFPEW1102-M 94031 240 DPST 40A 7.5HP @ 240V Freeze protection
included
PFPEW1103-M 94032 120/240
w/neutral DPST 40A 3 HP @ 120V
7.5HP @ 240V Freeze protection
included
PEW104-M 82442 240 DPST 40A 7.5HP @ 240V
PFEW104-M 94030 240 DPST 40A 7.5HP @ 240V Accepts PFPT
thermostat input
TORK 148
WIRING DIAGRAMS
POOL & SPA
JUNCTION BOXES
APPLICATIONS
For installation of underwater pool
lights or low voltage connections.
Solid brass with grounded post and
3 ground terminals for use with
metallic or PVC conduit.
ORDERING INFO
CATALOG
NO. UPC
CODE NPF CONDUIT HUB
A / B / C PIPE INPUT
SIZE
PB-50 94041
1
2
" /
1
2
" /
1
2
"
1
2
"
PB-75 94042
3
4
" /
3
4
" /
3
4
" .
3
4
"
PB-100 94043
3
4
" / 1"/
3
4
"
3
4
" & 1"
AB C
APPLICATIONS
FEATURES
TORK 149
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
POOL & SPA
CONTROLS
APPLICATIONS
FEATURES
SR-500 & SR-500PS
SAFETY VACUUM
RELEASE SYSTEMS
NEW!
A Safety Vacuum Release System (SVRS)
works by monitoring the vacuum on the
suction side of the pool or spa pump. When a
blockage occurs in the main drain or skimmer,
a sudden rise in vacuum will cause the SR-500
and SR-500PS to shut down and activate an
audible alarm. The pump will remain off with
the alarm sounding until manually reset.
Commercial & Residential
Swimming pools and spas
Fountains
Ponds
Any pump size
PROTECTION:
Provides an important layer of protection,
reducing entrapment risk.
Turns off pump in milliseconds upon detecting
sudden vacuum change.
Vacuum monitored 128 times per second,
rapid response and accurate readings.
Power monitored 50/60 times per second,
insures continuous power detection.
Newest state-of-art NEC microprocessor
technology-- guaranteed reliability and
performance.
WARNING ALARM: Multiple audible alarm
capabilities – allows for quicker alert to harmful
situations.
AUXILARY CONTACTS: Accessible extra dry
contact – auxiliary equipment can be added.
EQUIPMENT PROTECTION: Low vacuum
sensing - (prevents cavitations or running the
pump dry, eliminating costly equipment failure).
SCHEDULING: Programmable 24 hour timer,
or as stand-alone SVRS working in conjunction
with existing pool controller.
POWER OUTAGE BACKUP: Insures
settings and reading will be saved, 30 minute
rapid recharge.
MAINTENANCE OVERRIDE: 30 minute
maintenance override - (for pool or spa
service).
BUILT-IN DIAGNOSTICS: Displays
error codes, prevents guessing during
troubleshooting.
EASY RETROFIT: Integrates with common
existing timer box Trouble free installation, no
pipes to cut or glue.
COMPLIANCE: ASME/ANSI 112.19.17 as
required by the International Building Codes
(IBC) and the International residential Codes
(IRC). Meets all current codes and standards
for
SVRSs on new and existing pools and spas.
ENCLOSURE: Plastic Indoor/Outdoor NEMA
3R with lockable hasp. See page 153 for
dimensions and additional information.
Of all the protections you can put
between your family and the risk of
entrapment, the best protection is
AT THE SOURCE.
®
CONTACT RATINGS
ORDERING INFO
CATALOG
NO. UPC
CODE INPUT SUPPLY
(VAC) 60Hz DRY CONTACTS
(UNPOWERED)
SR-500 95425 120/240 DPST
SR-500PS 95426 120/240 DPST
TYPE VOLTAGE CONTACT
RATING
General Purpose 120VAC
240VAC 20A
Motor 120VAC
240VAC 3HP
INSIDE
THE POOL AREA
Minimize the
risk of entrapment
injuries or drowning
ALL ITEMS AVAILABLE FROM NSi/TORK!
More details available in our Safety Products catalog and Layers of
Protection brochure, ask your sales representative for more information.
LAYERS OF PROTECTION
FENCE & GATE
Restrict access to a pool or spa by surrounding the
area with fencing that is equipt with a self-closing,
self-latching gate closure. Utilize gate latches that
are adjustable, magnetically operated as well as key
lockable.
2
2
DOOR ALARMS
Door alarms on doors leading to the pool or spa area
help to alert parents or staff to anyone entering the
pool from the house or building.
Remote alarms linked to the Safety Vacuum Release
System (SVRS) alert parents or attendants when the
SVRS is activated, indicating that someone in the pool
may need help.
1
1
Make Your Pool & Spa Safer, Update your
OUTSIDE
THE POOL AREA
EMERGENCY STOP
An emergency STOP button allows parents or attendants in the
area to immediately and easily shut down the pump system in
the event of entrapment.
3
3
SVRS
The SVRS automatically shuts down the vacuum pump when
sensing a rise in vacuum pressure – in some cases, reacting to
potential entrapment conditions in LESS THAN ONE SECOND!
Audible alarms linked to the SVRS alert those nearby to a
potential entrapment.
SVRS should meet or exceed ASME/ANSI A112.19.17 standards
in order to comply with IRC and IBC codes.
4
4
DRAIN COVERS
Minimize potential entrapments or “Differential Hold Down
Forces,” thereby minimizing the potential for a swimmer to
be entrapped.
Anti-entrapment drain covers should meet or exceed ASME
and ANSI A112.19.8 2007 and 2007 Federal Pool & Spa
Safety Act and have a Certified Safe Flow Rating. Many
compliant drain covers are easily retrofitted to existing drains.
5
5
Keep children from
accessing the pool
or spa when
unattended
TORK 151
A DIVISION OF NSi INDUSTRIES, LLC
USA 800.321.5847 www.nsiindustries.com
POOL & SPA
CONTROLS
FEATURES
ANTI-ENTRAPMENT
DRAIN COVERS
ORDERING INFO
CATALOG
NO. UPC
CODE DESCRIPTION SURFACE AREA
(SQ.IN) RETROFIT
FRAME
DS360M 95431 Drainsafe Anti-Entrapment
Type Suction Outlet Cover 27 N/A
DS12X12P 95429 Drainsafe 12 x 12" Anti-Entrapment
Type Suction Outlet Cover 53 Pentair
DS12X12H 95430 Drainsafe 12 x 12" Anti-Entrapment
Type Suction Outlet Cover 53 Hayward
640-475XV 95432 Waterway 18 x 18"
Anti-Entrapment Drain Cover 159.6 18 x 18
AV20X20 95433 Eureka 20 x 20"
Anti-Entrapment Drain Cover 73.6 12 x 12
(9 x 9 minimum)
AV26X26 95434 Eureka 26 x 26"
Anti-Entrapment Drain Cover 108.9 18 x 18
(12 x 12 minimum)
DS360M DRAINSAFE
Designed for use with suction outlet sumps up
to 8" in size, will retrofit smaller 5” sumps using
additional knockouts.
Certified Safe flow of 123 GPM.
ASME/ANSI A112.19.8 2007 Standard Compliant.
DS12X12P DRAINSAFE
Designed to retrofit Pentair style frames, and
functions on dual drain as well as single suction
outlets.
Certified Safe flow of 250 GPM @ 1.5 FPS.
ASME/ANSI A112.19.8 2007 Standard Compliant.
DS12X12H DRAINSAFE
Designed to retrofit Hayward style frames, and
functions on dual drain as well as single suction
outlets.
Certified Safe flow of 250 GPM @ 1.5 FPS.
ASME/ANSI A112.19.8 2007 Standard Compliant.
640-475XV WATERWAY
Designed for single and multiple drain use, the
640-475XV works on dual drain as well as single
suction outlets.
Minimizes “Differential Hold Down Forces” of
dual drain systems.
Certified Safe flow rate of 540 GPM @ 1.09 FPS.
AV20X20 & AV26X26 EUREKA
Eureka drain covers unique grating system is
designed for new construction and retrofit, to add
protection from entrapment.
ASME/ANSI A112.19.8 2007 Standard Compliant.
Certified Safe flow rate of 223 GPM (20x20),
495 GPM (26x26).
DS360M
DS12X12P
DS12X12H
640-475XV
AV20X20 & AV26X26
NEW!
TORK 152TORK 152
POOL & SPA SAFETY
ACCESSORIES
FEATURES
SELF-LATCHING
GATE CLOSURES
& SELF-CLOSING
GATE HINGES
ORDERING INFO
CATALOG
NO. UPC
CODE DESCRIPTION FENCE
MATERIAL PACKAGING
AVAILABLE
MLTPS2BGA 95439 MagnaLatch Top Pull Gate Latch Wholesale
MLTPRP 95445 MagnaLatch Top Pull Gate Latch, 2" Gap
Spacer included Retail
MLVPS2BGA 95440 MagnaLatch Vertical Pull Gate Latch Wholesale
MLVPRP 95444 MagnaLatch Vertical Pull Gate Latch, 2"
Gap Spacer included Retail
MLS2RPAKA 95446 Round Post Adapter Kit Wholesale
MLSPACER 95447 MagnaLatch Gap Spacer Retail
REGULAR DUTY MODELS
TCA1RP-MK2 98018 TruClose® Regular Range Gate Hinge Metal Retail
TCA1-MK2 98026 TruClose® Regular Range Gate Hinge Metal Wholesale
TCA3RP-MK2 98019 TruClose® Regular Range Gate Hinge Vinyl, Wood Retail
TCA3-MK2 98027 TruClose® Regular Range Gate Hinge Vinyl, Wood Wholesale
TCAMA2RND 98024 TruClose® Regular Range Gate Hinge,
adjustable gap Round frames Wholesale
HEAVY DUTY MODELS
TCHD1ARP-MK2 98020 TruClose® Heavy Duty Metal Retail
TCHD1AL2-MK2 98021 TruClose® Heavy Duty, with 2 legs Metal Wholesale
TCHD2RP-MK2 98022 TruClose® Heavy Duty Vinyl, Wood Retail
TCHD2L2-MK2 98023 TruClose® Heavy Duty, with 2 legs Vinyl, Wood Wholesale
SAFETY ACCESSORIES
SR-RA 95437 Remote Alarm
SR-ESB 95438 Emergency Stop Button
DS-AA 95435 Drainsafe Masonry Anchor Kit - for
DS360M
DS-MR 95436 Drainsafe Mud Rings, Universal Fit
MAGNALATCH GATE CLOSURES
MagnaLatch quality latches are self-latching with
permanent magnets which never lose power, for
safer, child-resistant security for your swimming
pool gate. The Top Pull model can be mounted so
the release knob reaches the minimum code height,
typically 54", on a shorter gate. It's adjustable for
when the gate gets out of alignment. The Vertical
Pull model is designed for gates and fences that
are 60” or more in height.
TRUCLOSE GATE HINGES
TruClose® hinges are designed so the residential
homeowner can quickly and easily adjust tension to
support a 375lbs gate load and self-closes up to a
55lb gate, for the ultimate safety around pools and
other areas requiring self-closing gates. Hinges
are rust-free and are self-lubricating. Regular duty
and heavy duty models available.
ALL ITEMS AVAILABLE FROM NSi/TORK!
More details available in our Safety Products catalog and Layers of
Protection brochure, ask your sales representative for more information.
MLTPS2BGA
TCA1-MK2
TCHD1ARP-MK2
SR-RA
SR-ESB
DS-MR
DS-AA
NEW!
STANDARD
FOR MODELS METAL INDOOR NEMA 1
ENCLOSURE #68229
1101 7120
1102 7122
1103 8001
1104 8004
1101FM 8061
1104FM 8121
7100 8301
7102 8601
7200 8602
7202 TU40-Y
1101-7 EW201-Y
EW130B-Y EW120B-Y
STANDARD
FOR MODELS METAL INDOOR/OUTDOOR NEMA 3
MODEL 9000B – SUFFIX "O"
1101-O 1104-O
1102-O 7200-O
1103-O 7202-O
STANDARD
FOR MODELS METAL INDOOR NEMA 1
ENCLOSURE #63100
7220 1847AZL LDS-A
7222 8007 LDSH-A
7200L 8007L
7202L 8007V
7120L 8150
1847A 8150U
1848A 8007U
1849A 8007VL
1847AZ 8008
1847AL 8008L
STANDARD
FOR MODELS METAL INDOOR NEMA 1
ENCLOSURE #63016-1
TZ220L TW220L
TZ300L TW300L
W300 T920L
W302 T930L
W300L TW222L
W302L TW302L
#62158 "E" DOOR
T920L-E T930L-E
TW220L-E
STANDARD
FOR MODELS DLC400BP
DLC400BP
STANDARD
FOR MODELS METAL INDOOR NEMA 1
ENCLOSURE FOR W400 SERIES
W400A
W402A
W400AL
STANDARD
FOR MODELS
NORYL® & LEXAN®
INDOOR/OUTDOOR
NEMA 3R MODEL #9000NC
1101NC DGLC100A-NC
1103NC DGLC200A-NC
1104NC
8001-NC
STANDARD
FOR MODELS METAL INDOOR/OUTDOOR NEMA 3
MODEL #9006
TZ220L-0 TZ300L-0
TZ300L-0 T920L-0
T930L-0
MODELS PLASTIC INDOOR/OUTDOOR
NEMA 3R WITH CLEAR WINDOW
EW103B-C EW120B-C
NEMA 1 ENCLOSURE
STANDARD FOR MODELS
DTWH40
MODELS LC200M MOUNTING
WITH BRACKET
LC200M
STANDARD
FOR MODELS NORYL® INDOOR/OUTDOOR
NEMA 3R MODEL #9000N
7200Z, ZL 1101-N
7202Z, ZL 1102-N
7120Z, ZL 1103-N
7122Z, ZL 1104-N
DG Series DZS Series
8001-N DTS Series
8001U-N DW Series
SMC-3D DWZ Series
DZM Series
STANDARD
FOR MODELS METAL DUPLEX INDOOR/OUTDOOR
NEMA 3 MODEL #9004L
1101D 1101DF
1114D 1114DF
1104D 1104DF
TORK 153
ENCLOSURES
STANDARD
FOR MODELS
METAL INDOOR/OUTDOOR
NEMA 3
MODEL 9000A – SUFFIX "0"
7300, L, Z, ZL 8001-O
7302, L, Z, ZL 8001U-O
8007U-O 8007-O
DZS100BP-O DZS200BP-O
DZS200BP DW200B-O
DZM200BP-O 5401
STANDARD
FOR MODELS METAL INDOOR NEMA 1
ENCLOSURE #70100
W100 W220L
W200 W222L
W202 1847AW
W120 1847AWL
W220
W222
MODELS PLASTIC INDOOR/OUTDOOR
NEMA 3R #9000P
TU40 DTU40
E101PB
E Series
EW Series
EWZ Series
5-1/16"
8-5/16"
3-1/16"
9000P
5-1/16"
8-5/16"
3-1/16"
9000PC
11-7/8"
3-1/4"
7-5/8"
70100
MECHANISM ONLY MECHANISM & BRACKET
MECHANISM ONLY MECHANISM & BRACKET
MECHANISM & BRACKET MECHANISM & BRACKET
MECHANISM & BRACKET MECHANISM & BRACKET
6-5/8 "
4-9/16 "
TERMINAL BLOCK
1-15/16 "
2-3/32 "
3-1/16 "
3-5/8 "
6-5/8 "
4-9/16 "
TERMINAL BLOCK
BRACKET
DG SERIES
DZS, DTS,
DZM, DW,
DWZ
SERIES
6-5/8 "
4-9/16 "
TERMINAL BLOCK
1-15/16 " 3-1/16 "
6-5/8 "
4-9/16 "
TERMINAL BLOCK
BRACKET
E, EWZ, EH
SERIES
SMC-3D
4-11/16"
3-3/8"
3.4000"
4"
3-9/32 "
2-1/8 "
5-13/16 "
4-17/32 "
LC200M
1-13/16 "
SHOWN WITH
SNAP TRACK
5-37/64 "
3-13/32 "
LDS
LDSH
12-1/4"
14-1/4"
3-3/8"
DLC400BP
MODELS LDS SERIES MOUNTING
WITH BRACKET
LDS LDSH
POOL PANEL SERIES
TRP800
TRP800
TRP800
ELC74
ENCLOSURE
ELC74
ELC78 & ELC712
ENCLOSURE
ELC78
ELC712
IAP BRACKET
INTERMATIC ADAPTER PLATE
1101-M-IAP 7200
1104-M-IAP 7202
1102 7120
1103 7122
7100 E Series
7102 EW Series
EWZ Series
EWZ SERIES
EWZ101-MB
EWZ103-MB
EWZ120-MB
EWZ201-MB
TRP400
TRP400
TRP402
ELC71 & ELC72 SERIES
ENCLOSURE
ELC71PC/120
ELC71PC/208-240
ELC71PC/277
ELC72PC/120
ELC72PC/208-240
ELC72PC/277
MODELS MECHANISM &
MOUNTING BRACKET #62153-1
Use Bracket #64039
W100 W120
W200 W220
W202 W222
Use Bracket #62153-1
W300 W302
MODELS STINGL SVRS
ENCLOSURE
SR-500
SR-500PS
MODELS 5401 ENCLOSURE
5441
EWJT & E500T SERIES
ENCLOSURE
EJWT
E500T
E501T
E502T
MODELS MECHANISM & MOUNTING
BRACKET #65446
1101-M 1102-M
1103-M 1104-M
7000 Series 1847A, Z
1848A 8001-LC/WB
8601 8121
8602 8061
8301
7-1/2"
4-9/16" 3-1/2"
MECHANISM
ONLY MECHANISM
WITH BRACKET
TORK 154
ENCLOSURES
MECHANISM ONLY MECHANISM & BRACKET
MECHANISM ONLY MECHANISM & BRACKET
MECHANISM & BRACKET MECHANISM & BRACKET
MECHANISM & BRACKET MECHANISM & BRACKET
6-5/8 "
4-9/16 "
TERMINAL BLOCK
1-15/16 "
2-3/32 "
3-1/16 "
3-5/8 "
6-5/8 "
4-9/16 "
TERMINAL BLOCK
BRACKET
DG SERIES
DZS, DTS,
DZM, DW,
DWZ
SERIES
6-5/8 "
4-9/16 "
TERMINAL BLOCK
1-15/16 " 3-1/16 "
6-5/8 "
4-9/16 "
TERMINAL BLOCK
BRACKET
E, EWZ, EH
SERIES
SMC-3D
4-11/16"
3-3/8"
3.4000"
4"
3-9/32 "
2-1/8 "
5-13/16 "
4-17/32 "
LC200M
1-13/16 "
SHOWN WITH
SNAP TRACK
5-37/64 "
3-13/32 "
LDS
LDSH
MECHANISM ONLY MECHANISM & BRACKET
MECHANISM ONLY MECHANISM & BRACKET
MECHANISM & BRACKET
MECHANISM & BRACKET
MECHANISM & BRACKET MECHANISM & BRACKET
6-5/8 "
4-9/16 "
TERMINAL BLOCK
1-15/16 "
2-3/32 "
3-1/16 "
3-5/8 "
6-5/8 "
4-9/16 "
TERMINAL BLOCK
BRACKET
DG SERIES
DZS, DTS,
DZM, DW,
DWZ
SERIES
6-5/8 "
4-9/16 "
TERMINAL BLOCK
1-15/16 " 3-1/16 "
6-5/8 "
4-9/16 "
TERMINAL BLOCK
BRACKET
E, EWZ, EH
SERIES
SMC-3D
4-11/16"
3-3/8"
3.4000"
4"
3-9/32 "
2-1/8 "
5-13/16 "
4-17/32 "
LC200M
1-13/16 "
SHOWN WITH
SNAP TRACK
5-37/64 "
3-13/32 "
LDS
LDSH
5-1/2"
9-3/8"
3-3/4"
STINGL
4 1/4
7 1/2
13 3/8
PP-20R
PP-20R-P1
PP20R-P4
PP-20R-2P1
PP-20R-2P4
4 5/8
11”
17 3/4
PP-100R
PP-100R-P4
PP-100R-P1P4
PP-100R-2P4
PP-100R-P4P4FM
4 5/8
20 3/4
12 3/4
PP-125R
PP-125R-P4
PP-125R-2P4
PP-125R-P4-100X
PP-125R-P4-300X
4 1/2
9 3/4
6 1/8
PP-10R-M-GFCI
PP-10R-E-GRCI
4 1/4
7 1/2
13 3/8
PP-20R
PP-20R-P1
PP20R-P4
PP-20R-2P1
PP-20R-2P4
4 5/8
11”
17 3/4
PP-100R
PP-100R-P4
PP-100R-P1P4
PP-100R-2P4
PP-100R-P4P4FM
4 5/8
20 3/4
12 3/4
PP-125R
PP-125R-P4
PP-125R-2P4
PP-125R-P4-100X
PP-125R-P4-300X
4 1/2
9 3/4
6 1/8
PP-10R-M-GFCI
PP-10R-E-GRCI
4 1/4
7 1/2
13 3/8
PP-20R
PP-20R-P1
PP20R-P4
PP-20R-2P1
PP-20R-2P4
4 5/8
11”
17 3/4
PP-100R
PP-100R-P4
PP-100R-P1P4
PP-100R-2P4
PP-100R-P4P4FM
4 5/8
20 3/4
12 3/4
PP-125R
PP-125R-P4
PP-125R-2P4
PP-125R-P4-100X
PP-125R-P4-300X
4 1/2
9 3/4
6 1/8
PP-10R-M-GFCI
PP-10R-E-GRCI
4 1/4
7 1/2
13 3/8
PP-20R
PP-20R-P1
PP20R-P4
PP-20R-2P1
PP-20R-2P4
4 5/8
11”
17 3/4
PP-100R
PP-100R-P4
PP-100R-P1P4
PP-100R-2P4
PP-100R-P4P4FM
4 5/8
20 3/4
12 3/4
PP-125R
PP-125R-P4
PP-125R-2P4
PP-125R-P4-100X
PP-125R-P4-300X
4 1/2
9 3/4
6 1/8
PP-10R-M-GFCI
PP-10R-E-GRCI
GROUND
SCREW
CLEARANCE HOLE
FOR GROUND SCREW
ADAPTER
PLATE
TRP 400 (GROUP OF 4) TRP 800 (GROUP OF 8)
9/32"
MOUNTING HOLES
12"
4"
4"
18"
9/32"
MOUNTING HOLES
10"
12"
TRP 400 (GROUP OF 4) TRP 800 (GROUP OF 8)
9/32"
MOUNTING HOLES
12"
4"
4"
18"
9/32"
MOUNTING HOLES
10"
12"
WITH MOUNTING
BRACKET
#62153-1
#64039/62153-1/65447
MECHANISMS/BRACKETS
7-5/8"
7-5/8"
11-1/2"
MECHANISM
ONLY
WITH MOUNTING
BRACKET
#64039
MECHANISM
ONLY
11-1/2"
3-1/2"
2-1/2"
3-5/8 "
3-1/16"
14-1/8"
8-3/4" 4-3/16"
12-3/4"
10-1/8"
1/2" or 3/4" KO
3/4" or 1" KO
WIRING COMPARTMENT
1/2" or 3/4" KO
3/4" or 1" KO
1/4"
MOUNTING
HOLE
Note: Indoor Enclosure Only
5441 and 5440 REMOTE CONTACTORS
MECHANISM
ONLY MECHANISM
WITH BRACKET
#62153-1
MECHANISM
WITH BRACKET
#64039
3-1/2"
2-1/2"
7-5/8"
11-1/2"
3-5/8 "
3-1/16"
ALPHANUMERIC INDEX
1101 . . . . . . . . . . . . . . . . . . . . . . . . . 31, 144
1101-7 ...........................31
1101D ...........................144
1101FM-M ........................144
1101FM-N ........................144
1101-M ...........................31
1101-M-IAP ....................31, 144
1101-N ...........................31
1101-NC ..........................31
1101-O ...........................31
1102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
1102-M ...........................31
1102-N ...........................31
1102-O ...........................31
1103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
1103-M ...........................31
1103-N ...........................31
1103-NC ..........................31
1103-O ...........................31
1104 . . . . . . . . . . . . . . . . . . . . . . . . . 31, 144
1104D ...........................144
1104DF ..........................144
1104FM-M ........................144
1104FM-N ........................144
1104-M ...........................31
1104-M-IAP ....................31, 144
1104-N ..........................144
1104-NC ..........................31
1104-O .......................31, 144
1847A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
1847AL ...........................41
1847AW...........................41
1847AWL..........................41
1847AZ ...........................41
1847AZL ..........................41
1848A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2000-2 ...........................15
2000-7 ...........................15
2001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2005A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2007A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2008A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2223 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2224 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2421 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
401A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
402A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
403A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
405A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
422A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
454D ............................120
455D ............................120
457Z ............................120
460D ............................120
5001M............................19
5004M............................19
5007M............................19
5008M............................19
5021M............................19
5024M............................19
5026M............................19
5231 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5237 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
5403 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5404 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5404-3 ...........................22
5420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5441 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
5500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5500-OC ..........................24
5737TM ...........................23
5737TZ ...........................23
601A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
602A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
611A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
611D ............................122
621D ............................122
631D ............................122
640-475XV .......................151
652A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
654A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
655D ............................122
701A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
701AA ...........................101
711A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
7100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7120L ............................33
7120Z ............................35
7120ZL ...........................35
7122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7122ZL ...........................35
7200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7200L ............................33
7200-O ...........................33
7200Z ............................35
7200ZL ...........................35
7202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7202L ............................33
7202-O ...........................33
7202Z ............................35
7202ZL ...........................35
7220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7220L ............................33
7222 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7222L ............................33
7300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7300L ............................33
7300Z ............................35
7300ZL ...........................35
7302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7302L ............................33
7302Z ............................35
7302ZL ...........................35
73866 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
803B ............................123
806B ............................123
806D ............................123
8001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
8001-LC/WB .......................37
8001-N ...........................37
8001-NC ..........................37
8001-O ...........................37
8001U ............................37
8001U-N ..........................37
TORK 155
ALPHANUMERIC INDEX
8001U-O ..........................37
8004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
8007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
8007L ............................37
8007-O ...........................37
8007U ............................37
8007U-O ..........................37
8007V ............................37
8007VL ...........................37
8008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
8008L ............................37
8061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
8121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
8301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
8601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
90058-1 ..........................94
A502H ...........................105
A502HHW ........................105
A502HW .........................105
A506H ...........................105
A506HHW ........................105
A506HW .........................105
A512H ...........................105
A512HH..........................105
A512HHW ........................105
A512HW .........................105
A515M...........................105
A515MA..........................105
A515MH .........................105
A515MHW ........................105
A515MW .........................105
A530M...........................105
A530MA..........................105
A530MH .........................105
A530MHW ........................105
A530MW .........................105
A560M...........................105
A560MH .........................105
A560MHW ........................105
A560MW .........................105
AV20X20 .........................151
AV26X26 .........................151
C412H ...........................106
C460M...........................106
C502H ...........................106
C506H ...........................106
C512H ...........................106
C512HH..........................106
C515M...........................106
C530M...........................106
C560M...........................106
C560MH..........................106
D1060LA .........................104
D1060M..........................104
D1060MW ........................104
D212H...........................104
D212HA..........................104
D212HW .........................104
DG100A...........................63
DG100A...........................63
DG180A...........................85
DG200A...........................63
DG280A...........................85
DG280A-24 ........................85
DGLC100A-NC ......................79
DGLC200A-NC ......................79
DGM100A .........................63
DGM100A-Y........................63
DGS100A ..........................85
DGS100A-12 .......................85
DGS100A-24 .......................85
DGU100A-Y ........................79
DGUM100A ........................79
DGUM100A-Y.......................79
DIN100B ..........................89
DIN200B ..........................89
DLC400BP .........................81
DS12X12H........................151
DS12X12P ........................151
DS360M..........................151
DS-AA ...........................152
DS-MR ...........................152
DTS100B ..........................67
DTS200B ..........................67
DTS400B ..........................67
DTU40 ............................55
DTWH40 ..........................55
DW200B .........................145
DW200B-O........................ 145
DTWH40 ..........................55
DWZ100B .........................69
DZM200BP.........................71
DZM200BP-O.......................71
DZS100BP .........................65
DZS100BP-O .......................65
DZS200BP .........................65
DZS200BP-12 ......................65
DZS200BP-24 ......................65
DZS200BP-O .......................65
DZS400BP .........................65
DZS400BP-O .......................65
E101B ............................57
E101PB ...........................57
E103B ............................57
E120B ............................57
E201B ............................57
E500T ............................87
E501T ............................87
E502T ............................87
EJWT .............................87
ELC712 ...........................75
ELC71PC/120.......................73
ELC71PC/208-240 . . . . . . . . . . . . . . . . . . . 73
ELC71PC/277.......................73
ELC72PC/120.......................73
ELC72PC/208-240 . . . . . . . . . . . . . . . . . . . 73
ELC72PC/277.......................73
ELC74 ............................75
ELC78 ............................75
ELS-1 ............................115
EPC1 .............................77
EPC2 .............................81
EPC-A.............................79
EPC-LC .........................73, 75
EW101B...........................59
EW103B...........................59
EW103B-C .........................59
EW103B-Y .........................59
EW120B...........................59
EW120B-C .........................59
EW120B-Y .........................59
EW201B...........................59
EW201B-Y .........................59
EWZ101...........................61
EWZ101-MB........................61
EWZ103...........................61
EWZ103-MB........................61
EWZ120...........................61
EWZ120-MB........................61
EWZ201...........................61
EWZ201-MB........................61
TORK 156
ALPHANUMERIC INDEX
HPS30 ............................93
LC200 ............................77
LC200M ...........................77
LCS115M ......................75, 112
LDS ..............................83
LDS-A.............................83
LDSH .............................83
LDSH-A ...........................83
MLS2RPAKA .......................152
MLSPACER ........................152
MLTPRP ..........................152
MLTPS2BGA .......................152
MLVPRP ..........................152
MLVPS2BGA .......................152
OSC10U ..........................114
OSC12PL .........................112
OSC15PLS ........................111
OSC20U ..........................114
OSC5PL ..........................112
OSC5U ...........................114
OSCS20UP ........................113
OSWS9P-120 ......................110
OSWS9P-277 ......................110
OSWS9PD.........................110
OSWS9PDM .......................110
P1101-2M ........................147
P1101FM-M .......................147
P1101-M .........................147
P1104-2M ........................147
P1104FM-M .......................147
P1104FM-M 240VAC................. 143
P1104-M .........................147
PB-100 ..........................148
PB-50 ...........................148
PB-75 ...........................148
PEW101-M........................148
PEW104-M........................148
PF1101FM-M ......................147
PF1101-M ........................147
PF1104FM-M ......................147
PF1104-M ........................147
PFEW101-M .......................148
PFEW104-M .......................148
PFP1102 .........................143
PFP1102-M .......................147
PFP1103 .........................143
PFP1103-M .......................147
PFP2 ............................143
PFP2-M ..........................147
PFP3 ............................143
PFP3-M ..........................147
PFPEW1102 .......................143
PFPEW1102-M .....................148
PFPEW1103 .......................143
PFPEW1103-M .....................148
PFPT.............................143
PP-100R..........................141
PP-100R-2P4 ......................141
PP-100R-F2F4FM ...................143
PP-100R-P4 .......................141
PP-100R-P4P1 .....................141
PP-100R-P4P4FM...................141
PP-10R-E-GFCI .....................141
PP-10R-M-GFCI.....................141
PP-125-2P4 .......................141
PP-125R..........................141
PP-125R-P4 .......................141
PP-125R-P4-100X ..................141
PP-125R-P4-300X ..................141
PP-20R...........................141
PP-20R-2P1 .......................141
PP-20R-2P4 .......................141
PP-20R-F2 ........................143
PP-20R-P1 ........................141
PP-20R-P4 ........................141
SMC3D............................91
SR-500...........................149
SR-500PS.........................149
SR-ESB...........................152
SR-RA............................152
SS13B ...........................103
SS13F ...........................103
SS20 ............................103
SS20F ...........................103
SS700Z ...........................99
SS700ZA ..........................99
SS720A ...........................98
SS720AA ..........................98
SS721Z ...........................99
SS721ZA ..........................99
SSA100 ..........................102
SSA100R-24....................... 102
SSA200 ..........................102
SSA200R-24....................... 102
T920L ............................45
T920L-E ...........................45
T920L-O........................... 45
T930L ............................45
T930L-E ...........................45
T930L-O........................... 45
TA09 ............................133
TA1245Y-50 .......................137
TA1245Y-75 .......................137
TA131DAN5 . . . . . . . . . . . . . . . . . . . . . . . 136
TA131DAU . . . . . . . . . . . . . . . . . . . . . . . . 136
TA131DRN5 . . . . . . . . . . . . . . . . . . . . . . . 136
TA131DRU1 . . . . . . . . . . . . . . . . . . . . . . . 136
TA152 ...........................133
TA154 ...........................133
TA1786B .........................134
TA1786CB ........................134
TA1880 B.........................132
TA1880 G.........................132
TA1882 B.........................132
TA1882 G.........................132
TA1886 B.........................132
TA1886 G.........................132
TA1887 B.........................132
TA1887 BK........................132
TA1887 G.........................132
TA215LB .........................134
TA236 ...........................133
TA270A ..........................130
TA315-1N5........................130
TA340-10G5.......................128
TA340-4G5........................128
TA340-4N5........................128
TA340-6G5........................128
TA340-6N5........................128
TA371LRN5 .......................135
TA434-10N5.......................128
TA434-6N5........................128
TA44 ............................133
TA45 ............................133
TA46 ............................133
TA47AN5 .........................135
TA47AR5 .........................135
TA47RN5 .........................135
TA502 ...........................133
TA502-BX.........................138
TA502SW . . . . . . . . . . . . . . . . . . . . . . . . . 138
TORK 157
ALPHANUMERIC INDEX
TA503 ...........................133
TA503SW . . . . . . . . . . . . . . . . . . . . . . . . . 138
TA52AN5 .........................135
TA52BN5 .........................135
TA52RN5 .........................135
TA53AE1 .........................136
TA53AF1 .........................136
TA53AG ..........................136
TA53RE1 .........................136
TA54AE1 .........................136
TA54RE1 .........................136
TA5508H-G1 ......................127
TA590 ...........................137
TA591 ...........................137
TA592 ...........................137
TA598 ...........................137
TA599 ...........................137
TA60 ............................133
TA600 ...........................134
TA601 ...........................134
TA602 ...........................134
TA603L...........................134
TA606 ...........................137
TA61 ............................133
TA62 ............................133
TA620 ...........................134
TA620B ..........................134
TA620L...........................134
TA620LB .........................134
TA631L...........................134
TA635 ...........................134
TA640 ...........................137
TA656B ..........................134
TA666BK .........................134
TA725 ...........................129
TA740 ...........................129
TA744 ...........................129
TA874-N5.........................127
TA874-N5R........................127
TA875-1G1........................128
TA875-G1.........................127
TA876-N5.........................127
TA879 ...........................136
TA880-N5.........................127
TA93-2AN5........................135
TA93-2BN5........................135
TA93-2CN5........................ 135
TA93-2RN5........................135
TA94AN5 .........................135
TA94BN5 .........................135
TA94RN5 .........................135
TA-ADA...........................138
TA-ADB...........................138
TA-ADR...........................138
TA-B1............................138
TA-B2............................138
TA-B3............................138
TA-B-8332 ........................132
TA-BBSF ..........................138
TA-B-KHD-1000-PP..................131
TA-B-KHD-120VAC ..................131
TA-B-KHS-1000-PP ..................131
TAC210W .........................129
TAC212WL ........................129
TAC212WS ........................129
TA-D5B...........................138
TA-D6A...........................138
TA-D6C...........................138
TA-D6R...........................138
TA-D7A...........................138
TA-D7B...........................138
TA-D7C...........................138
TA-D7R...........................138
TA-D8A...........................138
TA-D8R...........................138
TA-L10 ...........................138
TA-L10-1 .........................138
TA-L12 ...........................138
TA-L3 ............................138
TA-L4 ............................138
TA-L6-2 ..........................138
TA-L8 ............................138
TA-L9 ............................138
TA-M1 ...........................138
TA-MTS...........................128
TA-SFPF ..........................138
TA-SFPFR .........................138
TA-WBBF .........................138
TCA1-MK2 ........................152
TCA1RP-MK2 ......................152
TCA3-MK2 ........................152
TCA3RP-MK2 ......................152
TCAMA2RND.......................152
TCHD1AL2-MK2 ....................152
TCHD1ARP-MK2 ....................152
TCHD2L2-MK2 .....................152
TCHD2RP-MK2 .....................152
TRP-1.............................94
TRP-2.............................94
TRP400 ...........................94
TRP402 ...........................94
TRP800 ...........................94
TRP802 ...........................94
TRP-U.....................79, 112, 116
TU40 .............................29
TU40-Y............................29
TW-220L ..........................47
TW-220L-E ........................47
TW-222L ..........................47
TW-300L ..........................47
TW-302L ..........................47
TZ-220L ...........................49
TZ220L-O..........................49
TZ-222L ...........................49
TZ-300L ...........................49
TZ-300L-O .........................49
TZ-302L ...........................49
USB-MMP..........................65
W100.............................43
W120.............................43
W200.............................43
W202.............................43
W220.............................43
W220L............................43
W222.............................43
W222L............................43
W300.............................43
W300L............................43
W300-O...........................43
W302.............................43
W302L............................43
W400A............................43
W400AL...........................43
W402A............................43
TORK 158
NOTES
TERMS OF SALE
TORK VENDOR NUMBER: 662381
1. Prices are F.O.B. our plant.
2. Prices do not include any sales tax.
3. Freight charges will be prepaid on all orders $100.00
and over shipping within continental USA using standard
shipping methods and service.
4. Minimum order – $100.00.
5. Claims for shortage, erroneous charges or price corrections
shall be deemed waived unless made in writing, delivered
to NSi within 30 days of invoice.
6. Terms of payment 2% 10th prox. net 25th following.
7. Warranties – We strive to produce the highest quality
products on the market today. NSi guarantees all products
to be free of defects in material and workmanship for
a period of 90 days from date of sale. Any claims for
defective material must be agreed to in writing by NSi.
Defective material will be replaced on an F.O.B., our
factory basis. NSi disclaims the implied warranty of fitness
for a particular application.
OTHER PRODUCTS AVAILABLE
NSi can provide many other products for special applications
which are not listed in this catalog. If you require an item which
you do not find listed, please contact us. We would be pleased
to provide a quotation upon receipt of a drawing or a sample.
GUARANTEE
It is our goal to provide extraordinary
products and services on a daily basis. If our
products or service do not meet with your
satisfaction, please let us know immediately
and we promise to make every reasonable
effort to remedy the situation.
ADDRESS
9730 Northcross Center Court
Huntersville, North Carolina
28078 USA
PHONE
office 800.321.5847
technical support 888.500.4598
FAX
800.841.5566
EMAIL
nsi@nsiindustries.com
WEB
www.nsiindustries.com

Navigation menu