: - 10/12/13

TRITON
INDUSTRIAL DEHUMIDIFIER
OWNER’S MANUAL

www.eipl.co.uk
Page 1 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

TRITON
PACKAGE CONTENTS
Item

Description

Quantity

11393GR-US

Dehumidifier

1

3086144

Quick release hose coupling

1

3944110

PVC Tube – 3/8” I/D

7.8M

TPC224

Manual

1

Page 2 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

INTRODUCTION
Designed for a wide range of applications, the Triton dehumidifier is a super
high capacity industrial unit which provides fast and efficient drying.
The Triton has a number of special features:

•
•
•
•
•
•
•
•
•

Super high efficiency rotary compressor
Temperature-sensitive microprocessor controlled defrost system
Exterior epoxy powder-coated finish
Inlet air filter
Internal condensate pump
Pump purge system
Rugged trolley for portability
Retractable handle mechanism
Extra long power cord

The fan draws the moist air through the inlet grille on the back of the unit, and
then through the cold evaporator coil, which cools the air below its dew point.
Moisture forms on the evaporator coil and is collected in the condensate tray,
which is equipped with a permanent drain. The cooled air then passes
through the hot condenser coil where it is reheated using the same energy
removed during the cooling phase, plus the additional heat generated by the
compressor. The air is, therefore, discharged from the dehumidifier at a
slightly higher temperature with a lower absolute humidity than that which
entered. Continuous circulation of air through the dehumidifier gradually
reduces the relative humidity within the area.
The Triton dehumidifier is a rugged, reliable drying unit designed to operate
effectively over a broad range of temperature and humidity conditions.
The unit incorporates a welded and galvanized steel chassis and is finished in
an epoxy coating for resilience to damage caused by rough handling.

Page 3 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

SPECIFICATIONS

MODEL: TRITON
HEIGHT: 29” (736mm)
WIDTH: 20” (508mm)
DEPTH: 15” (381mm)
WEIGHT: 75 lbs (34Kg)
AIRFLOW: 282 CFM (476 M3/hr)
POWER SUPPLY: 110V/ 60Hz/ 1 ph
FINISH: Powder-coated Epoxy
OPERATING RANGE: 33°F – 95°F
REFRIGERANT: R-407c (16.2 oz)

"This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The
refrigeration system is hermetically sealed.
The Global Warming Potential (GWP) of refrigerants used in products manufactured by Ebac
Industrial Products Ltd is as follows
R134a – 1300
R407c – 1610
For type and weight of refrigerant contained in this unit, please refer to the product data label"

Page 4 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

OPERATION
The following procedures should be followed to test the Triton for correct
operation:
1.

After unpacking, examine all external features to confirm damagefree shipment. Report all defects and damage at once. Connect the
power cable to a grounded 15 Amp electrical outlet.

2.

Check dehumidification process as follows:

CAUTION:
DO NOT REMOVE COVERS WHEN UNIT IS IN OPERATION

A. Place unit on a level surface.
B. Start up unit by switching to “ON”.
C. Check that air is being delivered through the front outlet grille
and the compressor is running.
D. Leave the machine running for 60 minutes.
E. Check to ensure there is sign of water extraction through the
condensate drain.
F. Test the pump surge system operation by holding the
momentary pump switch for 5 to 10 seconds. This switch allows
you to drain the pump reservoir at the end of a drying job
If, after carrying out the above procedures, the unit does not appear to
function properly, refer to the Troubleshooting section, which follows,
or contact the Factory Service Center.

CAUTION:
ONCE THE UNIT HAS BEEN SWITCHED OFF, WAIT AT
LEAST FIVE MINUTES BEFORE RESTARTING.

Page 5 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

ROUTINE MAINTENANCE
WARNING:
ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN
DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTNENANCE

To ensure continued full efficiency of the dehumidifier, maintenance
procedures should be performed as follows:
1.

Replace or clean the inlet air grille as required. Clean the surface
of the evaporator and condenser coils by blowing the dirt out from
behind the fins with compressed air. Hold the nozzle of the air hose
away from the coil to avoid damaging the fins. Alternatively,
vacuum clean the coils.
WARNING:
DO NOT STEAM CLEAN REFRIGERATION COILS

2.

Check that the fan is firmly secured to the motor shaft and that the
fan rotates freely. The fan motor is sealed for life and therefore
does not need oiling.

3.

To check the refrigerant charge, run the unit for 15 minutes and
briefly remove the top cover. The evaporator coil should be evenly
frost coated across its surface. At temperatures above 70°F, the
coil may be covered with droplets of water rather than frost. Partial
frosting accompanied by frosting of the thin capillary tubes,
indicates loss of refrigerant gas or low charge.

4.

Check all wiring connections.

IF ANY OF THE PRECEDING PROBLEMS OCCUR, CONTACT THE EBAC
SERVICE CENTER PRIOR TO CONTINUED OPERATION OF THE UNIT TO
PREVENT PERMANENT DAMAGE.

Page 6 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

REPAIRS
1.

Should an electrical component fail, consult the Factory Service
Center to obtain the proper replacement part.

2.

If refrigerant gas is lost from the machine, it will be necessary to use
a refrigeration technician to correct the fault. Contact the Factory
Service Center prior to initiating this action.
Any competent refrigeration technician will be able to service the
equipment. The following procedure must be used:
a. The source of the leak must be determined and corrected.
b. The machine
recharging.

should

be

thoroughly

evacuated

before

c. The unit must be recharged with refrigerant measured
accurately by weight.
d. For evacuation and recharging of the machine, use the crimped
and brazed charging stub attached to the side of the refrigerant
compressor.
The charging stub should be crimped and rebrazed after
servicing. NEVER allow permanent service valves to be fitted to
any part of the circuit. Service valves may leak causing further
loss of refrigerant gas.
3.

The refrigerant compressor fitted to the dehumidifier is a durable
unit that should give many years of service. Compressor failure can
result from the machine losing its refrigerant gas. The compressor
can be replaced by a competent refrigeration technician.
Failure of the compressor can be confirmed by the following
procedure:
a. Establish that power is present at the compressor terminals
using a voltmeter.
b. With the power disconnected, check the continuity of the internal
winding by using meter across the compressor terminals. An
open circuit indicates that the compressor should be replaced.
c. Check that the compressor is not grounded by establishing that
a circuit does not exist between the compressor terminals and
the shell of the compressor.

Page 7 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

TROUBLESHOOTING

SYMPTOM

CAUSE

Unit inoperative

1. No power to unit

Little or no airflow

1. Loose fan on shaft
2. Fan motor burnt out
3. Dirty refrigeration coils
4. Loose electrical wiring

Little or no water
extraction

1. Insufficient air flow
2. Compressor fault
3. Loss of refrigerant gas

Little or no defrost
when required

1. Faulty timer
2. Faulty by-pass valve

Unit vibrates
excessively

1. Loose compressor
2. Damaged fan

Water flooding inside
the machine

1. Drain pipe blocked/frozen
2. Drain pipe too high
3. Crimped or blocked tubing

Page 8 of 16

REMEDY
1. Check the power from
power supply panel
1. Tighten fan
2. Replace the fan motor
3. See Routine Maintenance
Section
4. Check the wiring diagram
to find fault and repair
1. Check all of the above
2. Contact the Factory
Service Center
3. Contact the Factory
Service Center
1. Contact the Factory
Service Center
2. Contact the Factory
Service Center
1. Tighten the nuts on the
compressor mounts
2. Replace fan
1. Clear the obstruction
2. Ensure that no section of
the drain hose is above the
level of the water outlet
3. Straighten, clear, or replace
tubing

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

TRITON
SPARE PARTS LIST

DESCRIPTION

NUMBER

PART
NUMBER

QUANTITY

Compressor
1

(RGA5456EXA)

3022170

1

N/A

1

3030908

1

Compressor Overheat
2

Protector

3

Compressor Capacitor
Evaporator/Condenser

4

Coil

2139330

1

5

Grille Filter

2013831

1

6

Filter Dryer

3020901

1

7

Fan Motor

3035788

1

8

By-pass Valve

3020811

1

9

Electronic Timer

1609850

1

10

Axial Fan

3040129

1

11

Rocker Switch

3035914

1

12

Thermistor Assy

3035142

1

13

Solenoid Coil

3030421

1

14

PVC Clear Tube

3014336

1

15

Silicone Tubing

3014368

1

16

Drain Tray

2131107

1

17

Qtr Turn Fastener

3087720

1

18

Qtr Turn Cam

3087721

1

19

Qtr Turn Washer

3087722

1

Page 9 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

20

Wheel

3050110

2

21

1” Starlock Washer

3082601

4

22

Condensate Pump

3160129

1

23

Purge Switch

3036779

1

24

Quick Disconnect

3086144

1

25

Snap Hose Clip

3086135

1

26

Hose Clip Snapper

3086136

1

27

Self Locking Pin-1/4x1.5

3087723

1

Spare parts available online
www.EIPLDIRECT.com

Page 10 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

Ebac

LIMITED WARRANTY

Our products carry a one-year unconditional warranty against any defects in
workmanship or material. This warranty will cover all parts and labour
required to repair your Ebac product. This warranty is invalid if the unit has
been abused, damaged, whether intentional or accidental, or if any
modifications have been made to the unit.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS ISSUED IN LIEU OF
ALL OTHER WARRANTIES (WHETHER WRITTEN, ORAL, OR IMPLIED)
INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
EBAC
SYSTEMS, INC. DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL
DAMAGES, LOST PROFITS, OR INCIDENTAL DAMAGES FOR BREACH
OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE
FOREGOING DESCRIBED MERCHANDISE.
For Your Records: Model:____________________
S/N:______________________
Date Received:______________

SAVE THIS SECTION FOR YOUR RECORDS
CLIP AND RETURN THIS CARD

PLEASE NOTE
To ensure that your
Ebac Dehumidifier is
accorded
the
full
coverage provided by
this warranty, please
complete and mail this
card at your earliest
convenience.

Thank You

WARRANTY REGISTRATION
DATE
MODEL ___________ S/N ________________ RECEIVED ________________
OWNER __________________________________________________________
ADDRESS ________________________________________________________
CITY __________________________ STATE ________ ZIP _______________
COMMENTS ______________________________________________________
_________________________________________________________________
Ebac Industrial Products, Inc.700 Thimble Shoals Blvd, Suite 109, Newport News,
VA. 23606-2575Tel: (757) 873 6800 Fax: (757) 873 3632 Website
www.ebacusa.com

Page 11 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

Page 12 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

Page 13 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

Page 14 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

Page 15 of 16

Drawing : - TPC224
Issue
:-7
Date
: - 10/12/13

UK Head Office

American Sales Office

German Sales Office

Ebac Industrial Products Ltd
St Helens Trading Estate
Bishop Auckland
County Durham
DL14 9AD

Ebac Industrial Products Inc
700 Thimble Shoals Blvd.
Suite 109, Newport News
Virginia, 23606-2575
USA

Ebac Industrial Products Ltd.
Gartenfelder Str. 29-37
Gebäude 35
D-13599, Berlin
Germany

Tel: +44 (0) 1388 664400
Fax: +44 (0) 1388 662590

Tel: +01 757 873 6800
Fax: +01 757 873 3632

Tel: +49 3043 557241
Fax: +49 3043 557240

www.eipl.co.uk
sales@eipl.co.uk

www.ebacusa.com
sales@ebacusa.com

www.eip-ltd.de
sales@eip-ltd.de

Page 16 of 16



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 16
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2013:12:10 09:59:17
Modify Date                     : 2013:12:10 09:59:17
Title                           : Microsoft Word - TPC224_7
Creator                         : PScript5.dll Version 5.2.2
Author                          : Wayne
EXIF Metadata provided by EXIF.tools

Navigation menu