Tork Catalog
User Manual: Tork-Catalog
Open the PDF directly: View PDF .
Page Count: 80
Download | |
Open PDF In Browser | View PDF |
PRODUCT CATALOG 2011 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com responsible energy A DIVISION OF NSi INDUSTRIES, LLC NSi Industries LLC About Us Since 1975, NSi’s strength is in the unique products that we bring to the market, combined with our exceptional ability to provide quality TORK® brand products manufactured in the company’s Mount Vernon facility. TORK® is NSi Industries largest brand, covering the categories of Electromechanical and Digital Time Switches, Signaling and Alert Devices, Pool and Spa Controls, Residential Timers, Photocontrols and Occupancy Sensors. For over 85 years, TORK brand recognition and reputation for quality and design make it the most specified brand in the industry. The TORK brand has a rich history beginning in the 1920s when the company introduced the first electromechanical time switch to the marketplace. Currently, TORK’s time switches maintain energy efficiency through lighting control in such high profile places as the Empire State Building, Washington DC Parks and Recreation, The Triborough Bridge, The Met Life Building and many more institutions across the country. As the most specified brand of time switches in the industry, TORK enjoys the hearty respect of engineers and project planners across all channels of distribution. In the past several years, we’ve introduced a number of TORK time switches, in-wall and plug-in timers to meet increasingly specific needs in the marketplace. We’ve also added a line of installer-friendly pool and spa panels and time switches, and are proud to offer essential pool safety products that meet and exceed federal requirements for safe pools. We look forward to designing and engineering more of our Responsible Energy products, helping save money and the environment through responsible and minimal use of energy. TABLE OF CONTENTS TABLE OF CONTENTS ENERGY CODE REFERENCE GUIDE . . . . . . . . . . . . . 7 PHOTOCONTROLS QUICK LOOK FEATURES & COMMON FEATURES . . . 2100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2110 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2001 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2020 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5000M SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 2005A, 2007A, 2008A SERIES . . . . . . . . . . . . . . . 5200 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5400 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5737 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . PHOTOCONTROL ACCESSORIES . . . . . . . . . . . . . . . 11 13 14 15 16 17 18 19 20 21 22 23 24 ELECTROMECHANICAL QUICK LOOK FEATURES & COMMON FEATURES . . . 27 TU40 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 1100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 7000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 7000Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 8000 SERIES, DUTY CYCLE . . . . . . . . . . . . . . . . . . 37 8000 SERIES, REPEATING VARIABLE CYCLE . . . . . . 39 WH2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 1800 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 W SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 T900 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 TZ SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 ELECTROMECHANICAL ENCLOSURES & DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . 153 DIGITAL QUICK LOOK FEATURES . . . . . . . . . . . . . . . . . . . . 53 DTU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 E SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 E-PB SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 EW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 EWZ SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 DG100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 DZS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 DTS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 DW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 DZM SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 ELC SERIES, 1 & 2 ZONE . . . . . . . . . . . . . . . . . . . 73 ELC SERIES, 4, 8 &12 ZONE . . . . . . . . . . . . . . . . . 75 LC200 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 DGU SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 DGLC SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 DLC400BP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 LD SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 DGS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 EJWT & E500T SERIES . . . . . . . . . . . . . . . . . . . . . 87 DIN SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 SMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 5401 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 HPS STARTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 TRP SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 DIGITAL ENCLOSURES & DIMENSIONS . . . . . . . . . 153 IN-WALL TIMERS QUICK LOOK FEATURES . . . . . . . . . . . . . . . . . . . . 97 SS720A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 98 SS700Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 99 SS721Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 99 701A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 711A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 SSA SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 SS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 C SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 OCCUPANCY SENSORS SENSOR TECHNOLOGY & PLACEMENT GUIDE . . . . 109 OSWS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 110 OSC15PLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 OSC12PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 OSC5PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 OSC20UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 OSC SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 ELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 TRP-U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 PLUG-IN TIMERS 400A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 400D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 600A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 600D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 120 121 122 123 TORK ALERT MECHANICAL STROBE HORNS . . . . . . . . . . . . . . . MECHANICAL HORNS . . . . . . . . . . . . . . . . . . . . . MULTI-TONE ELECTRONIC HORNS . . . . . . . . . . . . HEAVY DUTY BELLS . . . . . . . . . . . . . . . . . . . . . . BELLS & BUZZERS . . . . . . . . . . . . . . . . . . . . . . . CHIMES & CHIME KITS . . . . . . . . . . . . . . . . . . . . WEATHERPROOF MOTOR DRIVEN SIREN . . . . . . . MANUAL FIRE ALARM . . . . . . . . . . . . . . . . . . . . TELEPHONE STROBE . . . . . . . . . . . . . . . . . . . . . . TELEPHONE HORN . . . . . . . . . . . . . . . . . . . . . . . TELEPHONE RELAY . . . . . . . . . . . . . . . . . . . . . . . WALL CLOCKS . . . . . . . . . . . . . . . . . . . . . . . . . . ELECTRIC DOOR OPENERS . . . . . . . . . . . . . . . . . PUSH-BUTTONS . . . . . . . . . . . . . . . . . . . . . . . . . 127 127 128 128 129 129 130 130 131 131 132 132 133 134 WARNING LIGHTS, INDUSTRIAL . . . . . . . . . . . . . 135 WARNING LIGHTS, VEHICULAR . . . . . . . . . . . . . . 136 POWER SUPPLY UNITS . . . . . . . . . . . . . . . . . . . . 137 TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . 137 ACCESSORIES/REPLACEMENT PARTS/DIMENSIONS 138 POOL & SPA PP PANEL SERIES TIMERS . . . . . . . . . . . . . . . . . . 141 PFP PANEL SERIES TIMERS . . . . . . . . . . . . . . . . . 143 1100 SERIES TIMERS . . . . . . . . . . . . . . . . . . . . . 144 DW200B TIMER . . . . . . . . . . . . . . . . . . . . . . . . . 145 P1100 SERIES, 24 HOUR ELECTROMECHANICAL MECHANISMS . . . . . . . . . . 147 P1100 SERIES, 7 DAY DIGITAL MECHANISMS . . . 148 JUNCTION BOXES . . . . . . . . . . . . . . . . . . . . . . . 148 STINGL SR-500 & SR-500PS, SVRS . . . . . . . . . . 149 LAYERS OF PROTECTION . . . . . . . . . . . . . . . . . . . 150 ANTI-ENTRAPMENT DRAIN COVERS . . . . . . . . . . . 151 MAGNALATCH SELF-LATCHING GATE CLOSURES . . 152 TRUCLOSE SELF-CLOSING GATE HINGES . . . . . . . .152 POOL&SPA SAFETY ACCESSORIES . . . . . . . . . . . . 152 ENCLOSURE DIMENSIONS . . . . . . . . . . . . . . . . . . 153 ALPHANUMERIC INDEX . . . . . . . . . . . . . . . . . . . 155 LA N AR CH ITE CT U energy saving solutions Each of these marked products have features that decrease energy consumption and/or damage to the environment by one or more of the following: • Timed control, Photocontrol and/or Astronomic control of on responsible energy and off functions of lighting, fans, pumps and appliances • Timed control of systems or multiple zones of lighting • Photo or occupancy sensing control of lighting • Supercapacitor backup, no batteries to replace or dispose. • Helps meet CA Title 24, ASHRAE , IECC and other standards for responsible building products Small Space, Meeting Rooms, Restrooms, Storage Spaces: Occupancy Sensors, Interval Timers The first zone includes small spaces such as offices, restrooms and storage areas places where people may not occupy the space continuously. Individual wall switch replacement provides low cost installation, with occupancy sensors and interval timers as the best solution. In the event that wall switches provide proper coverage for the occupancy sensor, ceiling mounted options are available. FIC ES energy < Use the Quick Reference Energy Code Guide for approved products. responsible energy RE CE P TIO N responsible ZONE 1: SMALL SPACE Responsible Energy OF < Responsible Energy is the mark of TORK’s commitment to developing and manufacturing energy saving, environmentally friendly products. FIC ES solutions The first way to save energy begins with eliminating lighting when it isn't needed. As with exterior lighting, an efficient design matches controls to the typical use of the area. OF energy saving INTERIOR LIGHTING ZONES RA L& ENERGY CODE REFERENCE GUIDE ZONE 2: LARGE SPACE Small Space, Meeting Rooms, Restrooms, Storage Spaces: Time of Day with Override, Occupancy Sensors CALIFORNIA Title 24 LO T The first zone includes small spaces such as offices, restrooms and storage areas places where people may not occupy the space continuously. Individual wall switch replacement provides low cost installation, with occupancy sensors and interval timers as the best solution. In the event that wall switches provide proper coverage for the occupancy sensor, ceiling mounted options are available. ZONE 3: HARVESTING LIGHT CE ON T RO EXTERIOR LIGHTING ZONES EN When ambient light levels drop at dusk, lighting is needed to provide safety and security. BUT: Does all lighting need to be on all night long? The proper selection of lighting controls is essential to ensuring that energy is only used when needed. An efficient lighting control design creates zones of light levels that can be varied by time at night. Large of Small Spaces with Natural Light: Light Sensors, Light Sensors with Occupancy, Astronomic Timers. A third zone that uses daylighting control can be added to wither of the first two zones. light sensors can shut off a portion of the lighting when windows or skylights contribute sufficient natural light to the area. This "harvesting" of light is an excellent, green way to conserve energy. (NOTE: Energy codes vary on the stated maximum time, but shorter times can give more energy savings). E FIC FIC The first zone gives a minimum light level where security is the primary need. Determine what lighting is necessary, such as building-mounted wallpacks and a portion of the parking lot lighting. These should be on from dusk to dawn, and are best controlled by a photosensor device. OF ST RE Security Lighting (all night): Photocontrols, Photosensor controls OF WA R EH OU SE ZONE 1: MINIMUM LIGHT LEVEL / DUSK TO DAWN E RO O M OF RE FIC E ST RO O M CO NF ER FR B RO REA OM K OM PA R KIN G ASHRAE 90.1 ZONE 2: HIGHER LIGHT LEVEL / DUSK TO TIME OFF FRONT PARKING LOT Safety & Architectural Lighting (not necessary all night): Photosensor/Timebased controls, Astronomic controls The second zone provides a higher light level for safety, when people are normally present. Maximum levels for the parking lot and all walkway lighting are needed. These lights are best controlled by a combination photosensor and time-based device to allow shut-off during the night. The astronomic-calculated sunset/time control can also be useful. ZONE 3: ARCHITECTURAL / TIMED DUSK TO TIMED OFF ARCHITECTURAL & LANDSCAPING DOCKS & BACK PARKING LOT CONFERENCE ROOM RECEPTION OFFICES WAREHOUSE OFFICES RESTROOM RESTROOM Building Facade, Landscape and Signage: Astronomic controls The third zone covers architectural lighting for building facade or landscape and signs. These are best controlled with an astronomic-calculated sunset/time control. TORK 7 OFFICE OFFICE OFFICE BREAK ROOM TORK 8 PHOTOCONTROLS FEATURES QUICK LOOK COMMON FEATURES CHOICE OF PHOTOCELLS Cadmium sulphide, epoxysealed cells. Available in 1⁄2” and 1". 2100 SERIES 2110 SERIES 2000 SERIES 2001 SERIES 2020 SERIES 3000 SERIES 5000M SERIES 2005A SERIES 5200 SERIES 5737 SERIES Page 13 14 15 16 17 18 19 20 21 23 Mounting Conduit Conduit Conduit Conduit Conduit Flush Turn-Lock Turn-Lock Turn-Lock Turn-Lock Yes Yes Adjustable Swivel Housing Die Cast Die Cast Zinc Aluminum UV Stabilized UV Stabilized UV Stabilized Plastic Plastic Plastic UV Stabilized Plastic Lexan® Lexan® Lexan® Lexan® 1 - 5 fc 1 - 5 fc 1 to 3 fc 1 to 3 fc 1.5 fc 5 fc Turn ON Light Level 1 - 5 fc 1 - 5 fc 1 - 5 fc 1 - 5 fc Adjustable light level adjustment Yes Yes Yes Yes Turn OFF Ratio 3:1 3:1 3:1 3:1 3:1 3:1 5:1 3:1 1.5:1 1.5:1 Time Delay ON Yes Yes Yes Yes Yes Yes Yes Instant Instant Instant Time Delay OFF Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Light Sensor CdS CdS CdS CdS CdS CdS CdS CdS Silicon Diode Silicon Diode CFL Compatible Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Surge Protection Photo Timer TOUGH ENCLOSURES All conduit and flush mounted models utilize die-cast zinc, die cast aluminum, or genuine Lexan® materials. All turn-lock models utilize high impact UV stabilized polypropylene, ABS, PBT or Lexan® materials. CHOICE OF MOUNTING ORIENTATION Models are available in fixed position or 180° swivel. DEPENDABLE performance Built-in time delay prevents false switching due to light from passing highway vehicles, lightning, etc. Instant response is available in turn-lock models (5200 Series). TURN-LOCKS MEET ANSI C136.10 Yes All models meet the current ANSI requirements for locking-type prongs and color coded voltage designations. Locking prongs are solid brass. TORK® Photocontrols are designed and manufactured with components which adhere to the highest industry standards. Trained personnel and in-process quality procedures ensure that every unit meets our strictest quality standards. TORK 11 Color-Coded Dome Grey 105-130VAC Maroon 208-277VAC Blue 105-285VAC Yellow 480VAC Green 347VAC TORK 12 2100 SERIES SPECIFICATIONS SPECIFICATION GRADE 1/2" CONDUIT MOUNTING DIE CAST ZINC PHOTOCONTROL ON/OFF: Turn ON is 1 to 5fc, Turn OFF is 3 to 15fc, without the slide in position. ON/OFF adjustment is easily made by moving a slide cover. No tools required. APPLICATIONS SPECIFICATIONS SPECIFICATION GRADE 1/2" CONDUIT MOUNTING DIE CAST ALUMINUM PHOTOCONTROL ON/OFF: Turn ON is 1 to 5fc, Turn OFF is 3 to 15fc, without the slide in position. ON/OFF adjustment is easily made by moving a slide cover. No tools required. TIME DELAY: ON and OFF. TIME DELAY: ON and OFF. CELL: Cadmium sulphide, epoxy-coated, 1" diameter. CELL: Cadmium sulphide, epoxy-coated, 1⁄2” diameter. Model 2117 is 1" cell. CONTACTS: Remain closed between dusk and dawn. (The unit fails in the ON position). Parking lot lighting Building perimeter lighting Outdoor signage 2110 SERIES LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C. APPLICATIONS CONTACTS: Remain closed between dusk and dawn (the unit fails in the ON position). 2117 Parking lot lighting Building perimeter lighting Outdoor signage LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C. (2117 #10AWG red and black). 2115 & 2116 POWER CONSUMPTION: Averages under 1 watt. POWER CONSUMPTION: Averages under 1 watt. TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C). TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C). FAIL MODE: ON. FAIL MODE: ON. WARRANTY: 5 years. WARRANTY: 5 years. CONTACT RATINGS CONTACT RATINGS RATING CATALOG SWITCH WIRING DIAGRAMS NO. TUNGSTEN BALLAST FEATURES OPERATION: Delay of up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc. 2101 SPST 2000W 1800VA 2104 SPST 2000W 1800VA 2107 SPST 2000W 1800W 2000 SERIES HOUSING: Heavy Duty die cast zinc housing and base. Gasketed for maximum weather protection. WIRING DIAGRAMS VOLTAGE 50-60Hz 2101 60012 120VAC 2104 60013 208-277VAC 2107 60031 120/277VAC 73866 62020 Mounting Bracket 2100 SERIESDie case aluminum housing HOUSING: and base. Gasketed for weather protection. 2000 SERIES SWITCH 2115 RATING TUNGSTEN BALLAST SPST 2000W 1800VA 2116 SPST 3470-4620W 2080-2770VA 2117* SPST 3000W 3000VA 2100 WIRING SERIES DIAGRAMS ORDERING INFO ORDERING INFO UPC CODE OPERATION: Delay of up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc. ENERGY SAVINGS: Works with screw base CFLs and LED lamps. ENERGY SAVINGS: Works with screw base CFLs and LED lamps. CATALOG NO. FEATURES CATALOG NO. CATALOG NO. UPC CODE VOLTAGE 50-60Hz 2115 60032 120VAC 2116 60033 208-277VAC 2117* 60037 120VAC 73866 62020 Mounting Bracket *Not UL or CSA rated. PHOTOCONTROLS TORK 13 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 14 2000 SERIES SPECIFICATIONS 1/2" CONDUIT MOUNTING FIXED POSITION, LEXAN® HOUSING WITH WEATHERPROOF SEALANT PHOTOCONTROL ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3 to 15fc, without the slide in position. ON/OFF adjustment is easily made by moving a slide cover. No tools required. 2001 SERIES SPECIFICATIONS 1/2" CONDUIT MOUNTING 180° SWIVEL, LEXAN® HOUSING PHOTOCONTROL ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3 to 15fc, without the slide in position. ON/OFF adjustment is easily made by moving a slide cover. No tools required. TIME DELAY: ON and OFF. TIME DELAY: ON and OFF. Cadmium sulphide, epoxy-coated, 1⁄2” CELL: diameter. APPLICATIONS CONTACTS: Remain closed between dusk and dawn. (The unit fails in the ON position). Flood lamp Patio lamp Decorative lighting LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C. CELL: Cadmium sulphide, epoxy-coated, 1⁄2” diameter. APPLICATIONS CONTACTS: Remain closed between dusk and dawn. (The unit fails in the ON position). Flood lamp Patio lamp Decorative lighting LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C. POWER CONSUMPTION: Averages under 1 watt. POWER CONSUMPTION: Averages under 1 watt. TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C). TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C). FAIL MODE: ON. FAIL MODE: ON. WARRANTY: 5 years. WARRANTY: 5 years. CONTACT RATINGS RATING CATALOG WIRING DIAGRAMS SWITCH NO. TUNGSTEN BALLAST FEATURES OPERATION: Delay up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc. 2000 SPST 2000W 1800VA 2000-2 SPST 3470-4620W 2080-2770VA 2000-7* SPST 2000W 1800VA HOUSING: All Lexan® enclosures are impact and vandal resistant. Translucent Lexan® Dome prolongs cell life by further screening out ultraviolet rays. Dome and base are ultrasonically welded for maximum strength. WIRING DIAGRAMS 2000 SERIES ENERGY SAVINGS: Works with screw base CFLs and LED lamps. CONTACT RATINGS FEATURES OPERATION: Delay up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc. CATALOG NO. SWITCH 2001 2002 RATING TUNGSTEN BALLAST SPST 2000W 1800VA SPST 3470-4620W 2080-2770VA HOUSING: All Lexan® enclosures are impact and vandal resistant. Translucent Lexan® Dome prolongs cell life by further 2100 SERIES screening out ultraviolet rays. Dome and base are ultrasonically welded for maximum strength. WIRING DIAGRAMS Move Slide for Earlier or Later Turn ON ENERGY SAVINGS: Works with screw base CFLs and LED lamps. ORDERING INFO ORDERING INFO CATALOG NO. UPC CODE VOLTAGE 50-60Hz CATALOG NO. UPC CODE VOLTAGE 50-60Hz 2000 60017 120 2001 60015 120 2000-2 60018 208-277 2002 60016 208-277 2000-7* 62023 120/277 73866 62020 Mounting Bracket 73866 62020 Mounting Bracket • • Red Lamp • Move Slide for Earlier or Later Turn ON •240V L2 • L1 *Model 2000-7 has a cadmium sulphide, 1” epoxy cell. Also UL listed and CSA certified. Black Line White Neutral (Black) Line (White) (Red) • Lamp For 277VAC: L1 - Line L2 - Neutral PHOTOCONTROLS TORK 15 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 16 2020 SERIES SPECIFICATIONS 1/2" CONDUIT MOUNTING 180° SWIVEL, LEXAN® HOUSING PHOTOCONTROL ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3 to 15fc. ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3 to 15fc. CELL: Cadmium sulphide, epoxy-coated, 1⁄2” diameter. CELL: Cadmium sulphide, epoxy-coated, 1⁄2” diameter. POWER CONSUMPTION: Averages under 1 watt. Ideal for applications where it is essential to aim the photocell in an exact direction to sense natural light but avoid artificial light. FLUSH MOUNTING LEXAN® HOUSING PHOTOCONTROL TIME DELAY: ON and OFF. LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C. Flood and patio lamps Decorative lighting SPECIFICATIONS TIME DELAY: ON and OFF. CONTACTS: Normally closed (the unit fails in the ON position). APPLICATIONS 3000 SERIES CONTACTS: Normally closed (the unit fails in the ON position). APPLICATIONS Flush Mounting Model 3010 Pole lanterns Lawn lighting Walkways LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C. POWER CONSUMPTION: Averages under 1 watt. TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C). TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C). FAIL MODE: ON. FAIL MODE: ON. WARRANTY: 5 years. WARRANTY: 5 years. CONTACT RATINGS RATING CATALOG SWITCH NO. WIRING DIAGRAMS TUNGSTEN CONTACT RATINGS FEATURES CATALOG NO. OPERATION: Delay up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc. SWITCH UPC CODE VOLTAGE 50-60Hz 2021 60024 120 2022 60025 208-277 73866 62020 Mounting Bracket BALLAST SPST 2000W 1800VA 2022 SPST 3470-4620W 2080-2770VA WIRING DIAGRAMS 120V MODELS ORDERING INFO CATALOG NO. TUNGSTEN 2021 HOUSING: All Lexan® enclosures are impact and vandal resistant, cover and base are ultrasonically welded for maximum strength. ENERGY SAVINGS: Works with screw base CFLs and LED lamps. FEATURES RATING Line •Neutral • (Black) (White) (Red) Lamp L2 HOUSING & MOUNTING: Control housing is weather-resistant molded Lexan® with ultrasonically welded seams. MODEL 3000: Flush mounting through .6875” hole in post lantern or lighting fixture, 3⁄8” NPT, stem 3⁄4” long. Gasket and nut supplied. MODEL 3010: flush mounting into standard, raintight junction box. Includes plate and gasket to fit FS type outdoor junction box. ENERGY SAVINGS: Works with screw base CFLs and LED lamps. • 3000 SPST 2000W 1800VA 3002 SPST 3470-4620W 2080-2770VA 3006* SPST 1500W 1200VA 3010 SPST 2000W 1800VA WIRING DIAGRAMS 120V MODEL LAMP LINE BLK 120V RED NEUT. WHITE ORDERING INFO 208-277V MODELS L1 OPERATION: Delay up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc. BALLAST Line • (Black) • (White) 240V Neutral (Red) • For 277VAC L1 - Line L2 - Neutral Lamp CATALOG NO. UPC CODE VOLTAGE 50-60Hz 3000 60020 120 3002 60019 208-277 3006* 60026 347 3010 60021 120 208-277V MODEL For 277VAC: L1 - Line L2 - Neutral LINE BLK LAMP RED 240V WHITE *CSA certified only. PHOTOCONTROLS TORK 17 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 18 5000M SERIES SPECIFICATIONS DELAYED RESPONSE UTILITY GRADE MOV SURGE ARRESTOR PHOTOCONTROL ON/OFF: Turn-ON is 1 to 3 fc. Turn-OFF to Turn-ON ratio is 5 max. TIME DELAY: ON and OFF. CELL: Cadmium sulphide photocell responds to the light spectrum near to that of a human eye. Resists effects of moisture and airborne contaminants. APPLICATIONS RELAY: Bi-metal provides positive snap action switching, reducing bounce and prolonging contact life. For use on streets, highways and other luminaries equipped with locking type receptacles, where most stringent surge protection is needed. SURGE ARRESTOR: 380 joule MOV (metal oxide varistor) exceeds ANSI and NEMA requirements. LOCKING PRONGS: Solid brass for maximum corrosion resistance and electrical conductivity. TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C). OPERATION: Delayed response prevents false switching due to light from vehicles or lighting, etc. STANDARDS: Meets ANSI C136.10 including color designations. Also meets EEI NEMA standards. ON/OFF: Turn-ON is 1 to 3 fc. Turn-OFF to TurnON is 3 average. QUICK RESPONSE TURN-LOCK MOUNTING PHOTOCONTROL TIME DELAY: Instant ON/3-5 seconds OFF. CELL: Cadmium sulphide photocell responds to the light spectrum near to that of a human eye. Resists effects of moisture and airborne contaminants. APPLICATIONS CONTACTS: Solid brass prongs for maximum corrosion resistance and electrical conductivity. For use on streets, highways and other luminaries equipped with locking type receptacles, where instant response is required. SURGE ARRESTOR: 360 joules MOV exceeds NEMA and ANSI requirements. RELAY: Positive snap action switching, reducing bounce and prolonging contact life. Complies with ANSI C136.10 and EEI NEMA standards. TEMPERATURE RANGE: -40˚ to +158˚F (-40˚ to +70˚C). FAIL MODE: ON. FAIL MODE: ON. WARRANTY: 3 years. WARRANTY: 3 years. CATALOG NO. LIGHT SENSOR 5001M RATING TUNGSTEN BALLAST 1" 1200W 1800VA 5004M 1" 3470-4620W 2080-2770VA 5007M 1⁄2" 2000W 3470-4620W 1800VA 2080-2770VA HOUSING: Lexan® UV Stabilized, permanent color with UV resistant clear acrylic window. Models 5026M and 5008M with polypropylene dome. Provides high impact, flammability resistance and electrically safe operation. 5008M* 1" 1000W 1800VA 5021M 1⁄2" 2000W 1800VA ENERGY SAVINGS: Works with screw base CFLs and LED lamps. 5024M 1⁄2" 3470-4620W 2080-2770VA 5026M** 1⁄2" 1000W 1800VA ORDERING INFO CATALOG NO. UPC CODE VOLTAGE 50-60Hz COLOR 5001M 61012 105-130 Grey 5004M 61013 208-277 Maroon 5007M 61014 105-130/208-285 Blue 5008M* 61017 480 Yellow 5021M 61015 105-130 Grey 5024M 61016 208-277 Maroon 61045 SPECIFICATIONS CONTACT RATINGS FEATURES 5026M** 2005A, 2007A & 2008A 347 WIRING DIAGRAMS 2" 2 3/16" Green *Not UL listed or CSA certified. **CSA certified only. Receptacle Surface 2 3/16" FEATURES STANDARDS: Meets ANSI C136.10 including color designations. Also meets EEI NEMA standards. CONTACT RATINGS HOUSING: Polypropylene, UV Stabilized, permanent color with UV resistant clear acrylic window. Provides high impact, flammability resistance and electrically safe operation. ENERGY SAVINGS: Works with screw base CFLs and LED lamps. RATING CATALOG NO. TUNGSTEN BALLAST 2005A 1000W 1800VA 2007A 1000W 1800VA 2008A* 1000W 1800VA WIRING DIAGRAMS ORDERING INFO CATALOG NO. UPC CODE VOLTAGE 50-60Hz COLOR 2005A 62012 105-130 Grey 2007A 62013 105-285 Blue 2008A* 62014 400-550 Yellow 2" 2 3/16" Receptacle Surface 3 3/16" *Not UL or CSA listed. N L1 Line (Black) N Load (Red) Neutral (White) Load 105 to 285 volt single phase grounded supplies and loads L1 Line (Black) Load (Red) Neutral (White) Load 105 to 285 volt single phase grounded supplies and loads PHOTOCONTROLS TORK 19 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 20 5200 SERIES 5400 SERIES SPECIFICATIONS UTILITY GRADE ELECTRONIC WITH FAIL ON MODE PHOTOCONTROL SPECIFICATIONS 6000 WATT CONTACTORS WITH TURN-LOCK PHOTOCONTROL ON/OFF: Turn ON is 1.5 foot candle +/- 0.2 OFF/ON ratio is 1.5:1 average*. RECEPTACLE: 3-prong turn-lock meets the requirements of EEI NEMA. POWER CONSUMPTION: Maximum 3 watts during daylight. TIME DELAY: Instant ON/3-5 second OFF*. CELL: Silicon photosensor assures drift-free operation, turning on and off at the same light level consistently throughout the life of the unit. APPLICATIONS APPLICATIONS CONTACTS: DC relay has positive snap action switching, reducing bounce and prolonging contact life. Fail ON for safety. For use where the extreme accuracy and reliability of an electronic photocontrol is required and in the event of failure, light should stay ON for safety reasons. CONTACT RATINGS For street lighting. Controls all lighting loads in excess of the capacity of the photoelectric control contacts. SURGE ARRESTOR: 920 joule MOV (metal oxide varistor) exceeds ANSI and NEMA requirements. LOCKING PRONGS: Solid brass for maximum corrosion resistance and electrical conductivity. POWER CONSUMPTION: 1.0 watt average @ 120V. TEMPERATURE RANGE: -40˚ to +158˚F (-40˚ to +70˚C). CATALOG NO. SWITCH CONTACT RATING PER POLE 5403 DPST 3000W 5404 DPST 3000W 5404-3 DPST 3000W 5420 SPDT 3000W FAIL MODE: ON. WIRING DIAGRAMS WARRANTY: 5 years. *Consult factory for other ratios and time delays. 120 VOLT CIRCUIT MODEL WHT 5403 WHT LOAD STANDARDS: Meets ANSI C136.10 including color designations. Also meets EEI NEMA standards. HOUSING: UV stabilized, ANSI colorcoded, high impact polypropylene dome. Cross-linked polypropylene gasket. High impact ABS base. High impact, UV stabilized acrylic window. CONTACT RATINGS CATALOG NO. LIGHT SENSOR 5231 5237 TUNGSTEN BALLAST Silicon Photosensor 1000W 1800VA Silicon Photosensor 1000W 1800VA 2" ORDERING INFO WHT 78885 105-130VAC 5237 78886 105-305VAC Line (Black) Load (Red) Neutral (White) Load 105-305 VAC single phase grounded supplies and loads 3 1/8" 120V N 120 VOLT CIRCUIT MODEL 5420 105 to 285 volt single phase grounded supplies and loads CAS DIMENS RED LOAD 1 BLUE LOAD 2 WHT H 120V CATALOG NO. UPC CODE PHOTOCONTROL INCLUDED VOLTAGE 50-60Hz 5403 60009 5021M 105-130VAC 5404 60010 120 VOLT CIRCUIT MODEL WHT 5403 5024M 5404-3 60011 5024M 5420 60014 5021M BLK LOAD 1 CLOSES AT DUSK, OPENS AT DAWN LOAD 2 CLOSES AT DAWN, OPENS AT DUSK 277 VOLT CIRCUIT MODEL 5404-3 208-240VAC BLK RED WHT BLK RED WHT WHT BLK RED BLK RED 208 or 240 VOLT CIRCUIT MODEL 5404 277VAC LOAD WHT LOAD LOAD 105-130VAC LOAD LOAD LOAD LOAD WHT WHT WHT H H 120V N 120V N H H 120V 277V N 120V/240V 3-WIRE SYSTEM H H 277V/480V 4-WIRE SYSTEM CASE DIMENSIONS WHT RED 208V or 240V 208V/240V 4-WIRE SYSTEM Add photoelectric control dimensions 2" high x 3" diameter BLK BLUE LOAD 2 N Load 277V/48 BLK RED LOAD 1 Neutral (White) 277V N 120V/240V 3-WIRE SYSTEM WHT RED N L1 Load (Red) H H 120V 120 VOLT CIRCUIT MODEL 5420 Line (Black) LOAD WHT H 120V N 120V 2-WIRE SYSTEM 120V 2-WIRE SYSTEM N LOAD WHT H ORDERING INFO L1 Receptacle Surface VOLTAGE 50-60Hz 5231 N LOAD WHT ENERGY SAVINGS: Works with screw base CFLs and LED lamps. WIRING DIAGRAMS 2 3/16" UPC CODE HOUSING: Outdoor NEMA Type 3R. Beige enamel finish. Two 1⁄2”– 3⁄4” combination KO in bottom. RATING ENERGY SAVINGS: Works with screw base CFLs and LED lamps. CATALOG NO. BLK RED FEATURES WHT H 120V BLK 4-1/2" (114mm) 7-1/4" (184mm) FEATURES BLK RED 3-13/32" (87mm) LOAD 1 CLOSES AT DUSK, OPENS AT DAWN LOAD 2 CLOSES AT DAWN, OPENS AT DUSK PHOTOCONTROLS TORK 21 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 22 5737 SERIES TORK 5737 T Z PHOTO-TIMER ® SPECIFICATIONS ON AT DUSK, OFF AT MIDNIGHT ON EARLY MORNING, OFF AT DAWN PHOTO-TIMERS ON/OFF: Turn ON at dusk is 5.0 foot candle +/- 0.5 OFF/ ON ratio is 1.5:1 average. THE MOST FLEXIBLE PHOTO-TIMER FOR MAXIMUM ENERGY SAVINGS AND ALL ON/OFF NEEDS! TIME DELAY: Instant ON/3-5 seconds OFF. CELL: Silicon photosensor Midnight OFF: Allows user to adjust OFF time during the night. OFF time can be set for up to two hours before (for extra energy savings) or up to two hours after midnight. Use to stagger groups of lights to go OFF at different times during the night. Early Morning ON (537TZ only): Allows user to set number of hours after midnight (from 2-10 hours) that lights should turn back ON. APPLICATIONS Offices Restaurant signage Billboards Landscape and yard lighting No programming is required, the microprocessor tracks dusk and dawn times and automatically determines midnight, and corrects for Daylight Savings Time. It even re-learns and resets itself after a power outage, so that no maintenance is ever needed. CONTACTS: DC Relay, normally closed. Provides chatter free operation. Solid brass Prongs for maximum corrosion resistance and electrical conductivity. Ideal for situations when visible traffic is reduced – lights ON at dusk and OFF at 11pm or later, then on again for early morning illumination. TEMPERATURE RANGE: -40˚ to +158˚F (-40˚ to +70˚C). FAIL MODE: ON. WARRANTY: 3 years. PHOTOCONTROL ACCESSORIES FEATURES FOR TURN-LOCK CONTROLS OPERATION: Microprocessor tracks the dusk and dawn times with the seasons and automatically determines midnight, NO PROGRAMMING REQUIRED. Automatically "re-learns" and resets after power outage, eliminating costly maintenance. DST correction built in. CONTACT RATINGS CATALOG NO. SWITCH 5737TZ 5737TM TUNGSTEN BALLAST SPST 1000W 1800VA SPST 1000W 1800VA 2" ORDERING INFO VOLTAGE 50-60Hz 5737TZ 62010 105-305VAC 62009 DEVICE CATALOG NO. 5500 5500-OC 2 3/16" UPC CODE 5500 replaces photocontrol to change light fixture to always ON. 5500-OC replaces photocontrol to change light fixture to always OFF. Durable materials and gasket provide longevity and weatherproof protection. WIRING DIAGRAMS ENERGY SAVINGS: Works with screw base CFLs and LED lamps. CATALOG NO. REPLACEMENT CAPS RATING HOUSING: UV stabilized, ANSI color-coded polypropylene dome. UV stabilized, clear acrylic window. ABS base. Cross-linked, polypropylene gasket. 5737TM DUSK MIDNIGHTON OFF EARLY MO RNING ON DAWN OFF The TORK Photo-timer Plus is the most flexible photocontrol ever, operating like a photocontrol AND a time switch! Ideal for retrofit without expensive rewiring. The unit turns the load ON at sunset and can be preset to turn the load OFF up to two hours before or two hours after midnight. It can also be set to turn the load back ON from two to ten hours after midnight and OFF at dawn. 2" Receptacle Surface 3 1/8" N Load (Red) Load 61132 DEVICE Shorting cap 480VAC max 1800 Tungsten 1800VA Ballast Open cap 480VAC max (Black housing) CATALOG NO. UPC CODE DESCRIPTION 2223 61025 Receptacle with Neoprene gasket RECEPTACLE RECEPTACLE 120-480V receptacle with color-coded #14 leads, mounting bracket and one mounting screw. DEVICE 120 or 277V 2 3/16" Line (Black) 105-305 VAC single phase grounded supplies and loads 3 1/8" 61130 DESCRIPTION L1 Neutral (White) Receptacle Surface 105-305VAC N UPC CODE RECEPTACLE 120-480V receptacle with color-coded #14 leads, neoprene gasket and two mounting screws. CATALOG NO. UPC CODE DESCRIPTION 2224 61026 Receptacle and mounting bracket 120-480V receptacle with color-coded #14 leads, plastic housing, lock nut (with 1⁄2" NPT) and a mounting bracket. DEVICE CATALOG NO. UPC CODE DESCRIPTION 2421 61021 Receptacle with plastic housing and bracket L1 Line (Black) Load (Red) Neutral (White) Load 105-305 VAC single phase grounded supplies and loads FOR 240V, N=L2, L1=L1 PHOTOCONTROLS TORK 23 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 24 ELECTROMECHANICAL TIME SWITCHES FEATURES QUICK LOOK SERIES PAGE NO. CLOCK DIAL MINIMUM SETTINGS (MINUTES) ON OFF SKIP A DAY MANUAL SUNRISE/ OVERRIDE SUNSET COMMON FEATURES EASY TO SET DIAL ASSEMBLY Tork’s 24 hour dial assembly allows the user to set the time switch more accurately, easily moving it by hand in small increments. Dial can provide up to 12 ON/OFFs per day with cycles as short as 20 minutes. AM and PM settings are easy to see by the light and dark areas of the dial. MAX ON & OFF EVENTS PER DAY RATINGS RESERVE (AMPS) POWER SWITCH TYPES 29 24 Hour 15 15 Permanent 48 SPST DPST 1100 31 24 Hour 20 75 Yes 12 SPST DPST 7000 33 24 Hour 20 75 Yes Yes 12 SPST DPST SPDT DPDT 3PST 40 Available 7000Z 35 24 Hour 20 or 40 Minute Offset Yes Yes Astronomic 1 SPST DPST SPDT DPDT 3PST 40 Available TZ 49 24 Hour 20 or 40 Minute Offset Yes Permanent by circuit Astronomic 1 DPDT 3PST 20 Standard W 43 7 Day 60 120 Yes Yes 2 DPDT 3PST 4PST 40 Available TW 47 7 Day 60 120 Yes Permanent by circuit 2 DPDT 3PST 20 Standard T900 45 7 Day 60 120 Yes Permanent by circuit 2 SPDT 3 SPDT 20 Standard 1847A 41 24 Hour 20 75 Yes 1847AZ 41 24 Hour 1847AW 41 7 Day 20 or 40 Minute Offset 60 120 8000 37 24 Hour 15 8000 39 6, 12, 30 & 60 Min. Varies by dial 6 sec. to 1 min. WH2 40 24 Hour 20 TORK 27 15 75 Yes Yes Yes Yes Available Yes Photo Control Astronomic DPST DPDT For applications requiring many ON/OFF cycles per day, captive tabs on this dial tilt in and out just using your fingertip! TU40 SPST SPDT CAPTIVE TABS – DUTY CYCLE DIAL 40 SPRING WOUND RESERVE 40 SPDT 2 12 SPDT, Momentary Contact 10 Available 1 SPDT, Momentary Contact 10 Available 2 SPDT, Momentary Contact 10 Available 48 SPDT 20 30/dial SPDT 20 12 DPST 40 Available FIELD UPGRADEABLE ASTRONOMIC DIALS All Tork 24 Hour Time Switches can be upgraded in the field to astronomic operation. During power outages, precision spring mechanism takes over instantly and automatically. Keeps the mechanism on time up to 16 hours on 24 hour models and up to 24 hours on 7 day models. No resetting is needed after power resumes, and field installation is easy! ENCLOSED MOTOR Time switch motors are enclosed to protect from dust and damage. REMOVABLE DOOR Tork time switches feature removable doors to provide easy access for installation and wiring. TORK® Electromechanical Controls are designed and manufactured with components which adhere to the highest industry standards. Trained personnel and in-process quality procedures ensure that every unit meets our strictest quality standards. TORK 28 TU40 SERIES UNIVERSAL MULTI-VOLTAGE SAME ON/OFF TIMES EACH DAY 24 HOUR TIME SWITCH NEW! MORE WIRING SPACE! CONTACT RATINGS SPECIFICATIONS INPUT VOLTAGE: 120/208-240/277VAC, 60Hz (auto detection). TIMING ACCURACY: Line frequency. VOLTAGE NO NC General Purpose 120-277VAC 40A 30A Inductive 120-277VAC 30A 15A Ballast 120VAC 277VAC 30A 20A 10A 10A Tungsten 120VAC 15A 120VAC 240VAC 120VAC 240VAC 1HP, 30FLA, 90LRA 2HP, 20FLA, 60LRA 720VA 720VA Resistive 28VDC 20A Max above 104°F 120-277VAC 30A TERMINAL RANGE: #8 - #18 AWG. OPERATING TEMPERATURE: -31°F to 116°F (-35°C to +47°C). APPLICATIONS POWER CONSUMPTION: 6 watts maximum. Lighting Pumps Signs Air conditioning Water heaters Fans RATING TYPE ENCLOSURE: Polycarbonate Indoor/Outdoor NEMA 3R or -Y suffix metal indoor NEMA 1 enclosure. Both with lockable hasp standard (see page 153 for enclosure dimensions). Motor Load Pilot Duty ¼HP, 12FLA, 30LRA ½HP, 12FLA, 33LRA 290VA 360VA WIRING DIAGRAMS DTU40 ORDERING INFO FEATURES MULTI-VOLTAGE: Automatic input voltage detection. EASY SET: Real time clock face and day/night markings for setting trippers. Typical Wiring Diagram, Application Typical Wiring Diagram, 120120/277VAC VAC Application CATALOG NO. UPC CODE TIMER SUPPLY (VAC) 60Hz DRY CONTACTS (UNPOWERED) TU40 24000 120/208-240/277 DPDT TU40-Y 24001 120/208-240/277 DPDT ENCLOSURE TYPE Plastic Indoor/Outdoor NEMA 3R Metal Indoor NEMA 1 TIMER SUPPLY H N NC NO C NC LOAD L N N NO C LOAD L N L Typical Wiring Diagram, 208-240 VAC Application SCHEDULING: Minimum ON is setting 15 minutes. Dial has 96 captive trippers. TIMER SUPPLY H 4 in 1 CONTACTS: DPDT can also wire as SPST, SPDT, & DPST. N NC NO C NC NO C LOAD BYPASS SWITCH: Sets timer to permanent ON, OFF or timer operation. L1 L2 L1 VACATION MODE: Set timer OFF with no change of tripper settings. L2 DTWH40 INDICATING LIGHTS: Power ON green and load ON red and LED indicators. Typical Wiring120 Diagram, 120VAC Typical Wiring Diagram, 120/277VAC Application Typical Wiring Diagram, VAC Application TIMER SPECIFICATION WRITER’S GUIDE SUPPLY Furnish and install, where shown, a TORK time switch with 24 hour dial. The Time switch input shall be multi-voltage input 120/208/240/277VAC. Time Switch H N NC NO C NC NO C contacts shall be capable of switching 40 amperes per pole continuously up to 277 volts, and shall be DPDT, covering SPST, SPDT and DPST applications as LOAD96 trippers permits LOAD required. Captive ON/OFF trippers shall accomplish 1-48 operation per day. 15 minutes switching changes. Enclosure shall be Heavy duty lockable plastic Indoor/Outdoor NEMA 3R surface type, finished in beige, with combination 1⁄2”, 3⁄4” knockouts on bottom sides and back. Provisions shall be N L shall be TORK Model TU40_. made for positive padlocking. Terminal shall be capableL of receiving #8-#18N AWGL wire. The TimeN Switch Typical Wiring 208-240 VAC Application Typical Diagram, Wiring Diagram, 240VAC TIMER SUPPLY H ELECTROMECHANICAL CONTROLS TORK 29 N NC NO C NC NO C LOAD A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com L1 L2 L1 L2 TORK 30 1100 SERIES SAME DAY ON/OFF TIMES EACH DAY 24 HOUR TIME SWITCH SPECIFICATIONS CONTACT RATINGS INPUT VOLTAGE: 120 or 208-277 VAC 60 Hz, varies by model. TYPE APPLICATIONS Lighting Pumps Signs Air conditioning Water heaters Fans Automatic ON/OFF control when operation is required at the same time every day. FEATURES SCHEDULING: Minimum ON is setting 20 minutes with a minimum OFF setting of 75 minutes. Dial accommodates up to 12 pairs of trippers. One pair included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF automatic operation then resumes. ELECTROMECHANICAL CONTROLS TORK 31 ENCLOSURE TYPE CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 60Hz OUTPUT CONTACTS 1101 10011 120 SPST 1101-N 10040 120 SPST 1101-NC 10053 120 SPST 1101-O 10015 120 SPST Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor w/ clear Lexan® cover Metal Indoor/Outdoor NEMA 3 1101-M 10022 120 SPST Mechanism 1101-M-IAP 10052 120 SPST 1101-7 10033 347 SPST 1102 10012 208-277 SPST 1102-N 10045 208-277 SPST 1102-O 10046 208-277 SPST Mechanism and mounting plate Metal Indoor NEMA 1 Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Metal Indoor/Outdoor NEMA 3 1102-M 10035 208-277 SPST Mechanism 1103 10013 120 DPST 1103-N 10041 120 DPST 1103-NC 10054 120 DPST 1103-O 10016 120 DPST Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor w/ clear Lexan® cover Metal Indoor/Outdoor NEMA 3 1103-M 10023 120 DPST Mechanism 1104 10014 208-277 DPST 1104-N 10042 208-277 DPST 1104-NC 10055 208-277 DPST 1104-O 10017 208-277 DPST Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor w/ clear Lexan® cover Metal Indoor/Outdoor NEMA 3 1104-M 10014 208-277 DPST Mechanism 1104-M-IAP 10051 208-277 DPST Mechanism and mounting plate Replacement Trippers Order #P47 for a pair of ON/OFF trippers Replacement Motor #101 (120V) & #201 (208-277V) For Astronomic Conversion: Order #Z KIT A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com 40A TERMINAL RANGE: #8 - #14 AWG. Resistive OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C). Tungsten 120VAC 40A Inductive 120, 277VAC single phase 20A Pilot Duty 120 -277VAC 1000VA Motor 120VAC 240VAC 2HP 5HP POWER CONSUMPTION: 3 watts maximum. ORDERING INFO 120 -277VAC single phase 120 -277VAC single phase General Purpose TIMING ACCURACY: Line frequency. CONTACT RATING VOLTAGE ENCLOSURE: Lockable hasp. Type varies by model (see page 153 for enclosure dimensions). 40A Model 1101-7 is 30 AMP inductive at 347 volts and CSA only. OTHER MOUNTINGS: Intermatic® Adaptor Plate model #IAP allows any 1100 series to fit into an Intermatic case. WIRING DIAGRAMS 1101 & 1102 (SPST) 1103 (DPST) M Removable Bridge M L L 1 H 2 X LOAD N For separate motor terminals remove bridge from terminals 1 & L. M L H H TYPICAL FOR 240V SUPPLY 1 H N H LOADS M 1104 (DPST) (Both) 2 X LOAD 2 X 1 Must be same phase H L H 1 X 2 LOAD LOAD N TYPICAL FOR 277V SUPPLY Typical for double pole Cut motor lead at 1 SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch with 24 hour dial. The time switch shall be powered by a self-starting synchronous motor. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST as required). Removable ON/OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 75 minutes between one OFF period and the next. Enclosure shall be NEMA 1 surface type, finished in beige enamel, with combination 1⁄2”, 3⁄4” knockouts on bottom, both sides and back. Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time switch shall be TORK Model 11_ _ (11_ _–_, etc, to fit requirement). TORK 32 7000 SERIES CONTACT RATINGS SPECIFICATIONS WITH SKIP-A-DAY FEATURE RESERVE POWER OPTIONAL 24 HOUR TIME SWITCH TYPE INPUT VOLTAGE: 120 or 208-277 VAC 60 Hz varies by model. TERMINAL RANGE: #8 - #14 AWG. Resistive 120 -277VAC single phase 120 -277VAC single phase OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C). Tungsten 120VAC 40A Inductive 120, 277VAC single phase 20A Pilot Duty 120 -277VAC 1000VA Motor 120VAC 240VAC 2HP 5HP General Purpose TIMING ACCURACY: Line frequency. CALIFORNIA Title 24 APPLICATIONS ASHRAE 90.1 POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum. Lighting Heating Pumps Air conditioning Signs ENCLOSURE: Lockable hasp. Type varies by model (see page 153 for enclosure dimensions). NEW! FEATURES NEW! SCHEDULING: Minimum ON setting is 20 minutes with minimum OFF setting at 75 minutes. Dial accommodates up to 12 pairs of trippers. One pair included. SKIP-A-DAY: Omit operations on any day with a 7-spoke wheel marked with days of week. 3 omitting screws included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage. ELECTROMECHANICAL CONTROLS TORK 33 CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 60Hz OUTPUT CONTACTS 7100 10001 120 SPST 7102 10002 208-277 SPST 7200 11001 120 DPST 7200-O 10512 120 DPST 7202 11002 208-277 DPST 7202-O 10509 208-277 DPST 7300 7302 12001 12002 120 208-277 3PST 3PST 7120 13001 120 SPDT 7122 13002 208-277 SPDT 7220 14001 120 DPDT 7222 14002 208-277 DPDT ENCLOSURE TYPE Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3 Metal Indoor/Outdoor NEMA 3 Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor 7202L 19004 208-277 DPST NEMA 1 Metal Indoor/Outdoor 7300L 19005 120 3PST NEMA 3 Metal Indoor/Outdoor 7302L 19006 208-277 3PST NEMA 3 Metal Indoor 7120L 19007 120 SPDT NEMA 1 Metal Indoor 7220L 19009 120 DPDT NEMA 1 Metal Indoor 7222L 19011 208-277 DPDT NEMA 1 Replacement Order #P49 for a pair of ON/OFF per dial. Additional ON/OFF trippers per Trippers dial order #P47. 3 omitting screws #53005 supplied. Replacement #101 (120V) & #201 (208-277V). For "L" models #36 (120V) & #46 (208-277V). For Astronomic Conversion: Order #Z KIT for 7000 Series. Motor 19003 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com 120 40A WIRING DIAGRAMS 7100 SPST 7200 DPST 7100 SPST M M M 7300 3PST 7200 DPST L L L 2 L H H N X L 1 2 LOAD H N H 7120 SPDT 2 X M X 1 L LOAD LOAD H N H 2 L 3 L L L 5 L 6 L DPST H 1 LOAD X L H A N LOAD B N 2 1 L H LOAD X LOAD A B N 2H H N H 1 L N 3 LOAD N 5 LOAD 6 LOAD LOAD LOAD 7302 3PST 7120Z (SPDT) M M X L H H 4 LOAD L 1 3 M M M L 2 N 7220 DPDT (DPST) 7200Z 7220 DPDT M X 1 4 L LOAD N 7120 SPDT M 2 LOAD LOAD LOAD N 1 7300 3PST M M WITH RESERVE POWER 7200L 40A OTHER MOUNTINGS: Intermatic® Adaptor Plate model #IAP allows any 7100 and 7200 series (except “L” models) to fit into an Intermatic case. ORDERING INFO Automatic ON/OFF control when operation is required at the same time every day, with optional versatility of one to six days omission. CONTACT RATING VOLTAGE 5 N 2 2 X LOAD L 4 H X 1LOAD LOAD LOAD 3 LOAD LOAD 2 L N 5 H LOAD N L 1 3H 2 L 4 H L 6 LOAD LOAD N 1 X 2 H LOAD 5 N 4 X LOAD LOAD LOAD A LOAD B N H FOR USE WITH 3 PHASE 4-WIRE N 120/208V SYSTEMS. SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch with 24 hour dial and day-omitting device. The time switch shall be powered by a self-starting synchronous motor. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPST, SPDT, as required). Removable ON/OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 75 minutes between one OFF period and the next. Enclosure shall be NEMA 1 surface type, finished in beige enamel, with combination 1⁄2”, 3⁄4” knockouts on bottom, both sides and back. Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time Switch shall be TORK Model 7_ _ _ (to fit requirement). FOR RESERVE POWER (MODELS WITH SUFFIX “L”): Spring-driven reserve shall be provided sufficient to operate the time switch contacts at least 16 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit. TORK 34 7000Z SERIES ADJUSTS TO DAILY CHANGES IN SUNSET TIMES! WITH SKIP-A-DAY FEATURE RESERVE POWER OPTIONAL ASTRONOMIC TIME SWITCH CONTACT RATINGS SPECIFICATIONS TYPE INPUT VOLTAGE: 120 or 208-277 VAC 60 Hz, varies by model. TERMINAL RANGE: #8 - #14 AWG. Resistive 120 -277VAC single phase 120 -277VAC single phase OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C). Tungsten 120VAC 40A Inductive 120, 277VAC single phase 20A Pilot Duty 120 -277VAC 1000VA Motor 120VAC 240VAC 2HP 5HP General Purpose TIMING ACCURACY: Line frequency. CALIFORNIA Title 24 APPLICATIONS ASHRAE 90.1 POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum. Parking lots Walkways Outdoor signage Window displays Canopy lighting Landscape lighting ENCLOSURE: Lockable hasp. Type varies by model (see page 153 for enclosure dimensions). Automatic ON at dusk, OFF at dawn. Control of outdoor lighting. 42° ORDERING INFO SKIP-A-DAY: Omit operations on any day with a 7 spoke wheel marked with days of the week. 3 omitting screws included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage. CATALOG NO. 7200Z–* 7202Z–* 7300Z–* 7302Z–* 7120Z–* UPC CODE INPUT SUPPLY (VAC) 60Hz ** ** 120 208-277 ** ** 120 208-277 ** 120 OUTPUT CONTACTS DPST DPST 3PST 3PST SPDT ENCLOSURE TYPE Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor NEMA 3R Metal Indoor/Outdoor NEMA 3 Metal Indoor/Outdoor NEMA 3 Noryl® Indoor/Outdoor NEMA 3R WITH RESERVE POWER 7200ZL–* ** 120 DPST 7202ZL–* ** 208-277 DPST 7300ZL–* ** 120 3PST 7302ZL–* ** 208-277 3PST 7120ZL–* ** 120 SPDT 7122ZL–* ** 208-277 SPDT Replacement Motor Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor NEMA 3R Metal Indoor/Outdoor NEMA 3 Metal Indoor/Outdoor NEMA 3 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor NEMA 3R #101 (120V) & #201 (208-277V). For "L" models #36 (120V) & #46 (208-277V) *Add degrees latitude to complete number (18, 30, 34, 38, 40, 42, or 45). **Consult factory for UPC number. ELECTROMECHANICAL CONTROLS TORK 35 40A A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com 40° H N H 38° WASHINGTON OREGON L 7120Z (SPDT) M M 45° ASTRONOMIC SCHEDULING: Turn ON at sunset and OFF at sunrise daily. OFF time can be set from 8:30PM to 2:30AM. Can be individually offset +/- 20 or 40 minutes from both sunset and OFF times. Available from 18° - 45° northern latitudes. 40A WIRING DIAGRAMS ASTRONOMIC LATITUDE ZONES 7200Z (DPST) 7302 3PST FEATURES CONTACT RATING VOLTAGE X 2 UTAH LOAD WISCONSIN KANSAS L L 3 ILLINOIS ARIZONA L NEW MEXICO IND MISSOURI ARKANSAS N L RHODE ISLAND H DELAWARE MARYLAND VIRGINIA 6 LOAD LOAD B 1 N H N H 7302 3PST FLORIDA 18° HAWAII LOAD A N LOAD L 2 X 2 LOAD LOAD GEORGIA LOUISIANA 30° X H FOR USE WITH 3 PHASE 4-WIRE 7200Z (DPST) 120/208V SYSTEMS. MEXICO 1 CONNECTICUT NEW JERSEY NORTH CAROLINA SOUTH LOAD CAROLINA ALABAMA MASS PENNSYLVANIA 4 OHIO KENTUCKY TENNESSEE MISS TEXAS NH WEST VIRGINIA 5 OKLAHOMA VT 2 NEW YORK CALIFORNIA 34° X 1 M MAINE IOWA COLORADO LOAD M MICHIGAN L WYOMING NEBRASKA NEVADA MINN SOUTH DAKOTA IDAHO 1 NORTH DAKOTA MONTANA 7200Z (DPST) 18° PUERTO M 7120Z (SPDT) M M RICO L L 1 X L H N H LOAD 1 X 2 2 LOAD 3 L 4 5 6 LOAD X LOAD A LOAD B 2 H H L L 1 LOAD LOAD N N N FOR USE WITH 3 PHASE 4-WIRE 120/208V SYSTEMS. SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch with Astronomic dial and day-omitting device powered by a self-starting synchronous motor. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be (DPST, 3PST or SPDT) as required. ON operation shall occur automatically at sunset (in city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of adjustability of 20-40 minutes before or after sunset and sunrise. Enclosure shall be: DPST or SPDT is NEMA 3R indoor/outdoor – Noryl® – 3PST is NEMA 3 metal indoor/outdoor. Terminals shall be of the pressure type, capable of receiving #8 AWG wire. Time switch shall be TORK Model 7_ _ _Z (to fit requirement). FOR RESERVE POWER (Add Suffix L): Spring driven reserve shall be provided sufficient to operate the time switch contacts for at least 16 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit. TORK 36 8000 SERIES CONTACT RATINGS SPECIFICATIONS MANY DAILY ON/OFF OPERATIONS PER DAY DUTY CYCLE 24 HOUR TIME SWITCH INPUT VOLTAGE: 120, 208-277VAC or 480VAC, 60Hz, varies by model. TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG. ORDERING INFO ENCLOSURE TYPE CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 60Hz OUTPUT CONTACTS 8001 70001 120 SPDT 8001-N 70025 120 SPDT 8001-NC 70009 120 SPDT Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor NEMA 3R w/ clear Lexan® cover 8001-LC/WB 70010 120 SPDT Mechanism and bracket 8001-O 70029 120 SPDT 8004 70002 208-277 SPDT 8001U 70003 480/120 Trans. SPDT NEW! 8001U-N 70014 480/120 Trans. SPDT NEW! 8001U-O 70011 480/120 Trans. SPDT Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Metal Indoor/Outdoor NEMA 3 DUTY CYCLE: Adjustable from 1⁄2, 1, 2, 3, 4, 6, 12, and 24 hours. 24 HOUR WITH 7 DAY OMIT 70005 120 SPDT 8007-O 70012 120 SPDT 8008 70006 208-277 SPDT NEW! 8007U 70008 480/120 Trans. SPDT NEW! 8007U-0 70028 480/120 Trans. SPDT Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3 24 HOUR WITH 7 DAY OMIT & RESERVE POWER 8007L 70015 120 SPDT 8008L 70016 208-277 SPDT Metal Indoor NEMA 1 Metal Indoor NEMA 1 24 HOUR WITH 14 DAY OMIT 8007V 70007 120 SPDT Metal Indoor NEMA 1 SPDT Metal Indoor NEMA 1 24 HOUR WITH 14 DAY OMIT & RESERVE POWER 8007VL Replacement Motor TORK 37 120 or 240VAC 480VAC 20A 20A Motor 120VAC 3/4 HP OTHER MOUNTINGS: Intermatic® Adaptor Plate model #IAP allows 8001 & 8004 to fit into an Intermatic case. WIRING DIAGRAMS 70017 120 M ALL SPDT MODELS C L H 8007 SKIP-A-DAY: Some models include 7 day or 14 day wheel to omit selected days of the week. ELECTROMECHANICAL CONTROLS Resistive ENCLOSURE: Lockable hasp. Type varies by model (see page 153 for enclosure dimensions). 8001-N FEATURES OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage. CONTACT RATING POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum. For one or multiple daily ON/OFF operations. SCHEDULING: Minimum ON setting is 15 minutes with minimum OFF setting at 15 minutes. Dial accommodates up to 96 captive tabs. VOLTAGE OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C). APPLICATIONS Duty cycling Ventilating fans Pumping Irrigation Process control Laboratory experiments TYPE 120VAC N NC NO 2 LOAD 2 CLOSED WITH TAB OUTWARD LOAD 1 CLOSED WITH TAB INWARD SPECIFICATION WRITER’S GUIDE The time switches shall be of duty cycle type, capable of programming at 15 minute intervals of the day. Scheduled tabs shall be captive on the dial, and shall be easily set by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike. The unit shall be powered by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism shall be a self-contained unit rated at not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the field. FOR 8001 ADD: The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of the time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork Model 8007 or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit, which shall power the clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished with built-in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U. #101(120V) & #201 (208-277V). For “L” models #36 (120V) & #46 (208-277V) A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 38 8000 SERIES SPECIFICATIONS MULTIPLE ON/OFF CYCLES PER DAY REPEATING VARIABLE CYCLE TIME SWITCH INPUT VOLTAGE: 120VAC, 60Hz. APPLICATIONS 24 HOUR WATER HEATER TIME SWITCH INPUT VOLTAGE: 208 – 250V 60 Hz. TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG. TERMINAL RANGE: #8 - #14AWG. OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C). OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C). REPLACEMENT TRIPPERS: #P49 for a pair with one ON and one OFF per dial for additional ON/OFF trippers per dial order #P47. 3 omitting screws #53005 supplied. ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions). For one or many daily ON/OFF operations. SPECIFICATIONS TIMING ACCURACY: Line frequency. POWER CONSUMPTION: 3 watts maximum. Duty cycling Ventilating fans Pumping Irrigation Process control Laboratory experiments WH2 APPLICATIONS SAVE ENERGY! POWER CONSUMPTION: 3 watts maximum. Avoid utility peak rates Turn off when not needed Automatic ON/OFF control of electric water heaters. Schedules the water heater to turn ON only when needed, avoiding energy waste when hot water is not needed. ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions). CONTACT RATINGS CONTACT RATINGS FEATURES SCHEDULING: 60 captive tabs per dial with minimum ON/OFF settings: – 60 minute dial with 1 minute tabs. – 30 minute dial with 30 second tabs. – 12 minute dial with 12 second tabs. – 6 minute dial with 6 second tabs. TYPE VOLTAGE CONTACT RATING Resistive 120 or 240VAC 480VAC 20A 20A Motor 120VAC 3/4 HP CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 60Hz OUTPUT CONTACTS TYPE 8601 70034 120 SPDT 60 Minute 8301 70033 120 SPDT 30 Minute 8121 70032 120 SPDT 12 Minute C L H 120 SPDT 6 Minute 120VAC N Replacement For 8601 #102, for 8301 #108, for 8121 #107, and for 8061 #105. Motor Replacement #P49 for a pair with one ON and one OFF per dial for additional ON/OFF Trippers trippers per dial order #P47. 3 omitting screws #53005 supplied. ELECTROMECHANICAL PHOTOCONTROLS CONTROLS TORK 39 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com NC TYPE VOLTAGE CONTACT RATING Resistive 208-277VAC 40 A, 10,000W Replacement Motor #201 (208-277V) Replacement Trippers Order #P47 for a pair of ON/OFF trippers EXTERNAL MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF automatic operation then resumes. M ALL SPDT MODELS ORDERING INFO 70031 SCHEDULING: Minimum ON is setting 20 minutes with a minimum OFF setting of 75 minutes. Dial accommodates up to 12 pairs. 3 pairs of trippers supplied. WIRING DIAGRAMS DUTY CYCLE: Settings of 1⁄60 th of dial speed. 8061 FEATURES WIRING DIAGRAMS TYPICAL FOR 240 VOLT SUPPLY ORDERING INFO NO 2 LOAD 2 CLOSED WITH TAB OUTWARD CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 60Hz OUTPUT CONTACTS ENCLOSURE TYPE WH2 70042 208-250 DPST Metal Indoor NEMA 1 M H H L 1 2 X LOAD LOAD 1 CLOSED WITH TAB INWARD TORK 40 40 TORK 1800 SERIES CONTACT RATINGS SPECIFICATIONS FOR MECHANICALLY HELD CONTRACTORS AND LOW VOLTAGE REMOTE CONTROL MOMENTARY CONTACT TIME SWITCH INPUT VOLTAGE: 120VAC or 208-277VAC, 60Hz, varies by model. TIMING ACCURACY: Line frequency. TYPE VOLTAGE CONTACT RATING General Purpose 24-277VAC 10A Pilot Duty 24-277VAC 360VA TERMINAL RANGE: #12 - #22AWG. OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C). APPLICATIONS CALIFORNIA Title 24 Mechanically-held contactors 3-wire momentary lighting systems Remote station switching POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum. ASHRAE 90.1 ENCLOSURE: NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions). WIRING DIAGRAMS ORDERING INFO WASHINGTON FEATURES CATALOG NO. SCHEDULING: Choice of three types. 1847A 24 HOUR SKIP-A-DAY: Minimum ON setting is 20 minutes with minimum OFF setting at 75 minutes. Dial accommodates up to 12 pairs of trippers. Omit operations on any day with a 7 spoke wheel marked with days of week. 1848A UPC CODE INPUT SUPPLY (VAC) 60Hz 52001 52014 120 208-277 7 DAY SCHEDULING: Minimum ON setting is 1 hour with a minimum OFF setting of 2 hours. Minimum 8 hours between 2 OFF settings. 7 day calendar dial will accomodate up to 2 pairs on ON/ OFF trippers per day - 7 pairs are supplied. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. TORK 41 SPDT SPDT TYPE 42° 24 Hour OREGON NORTH DAKOTA MONTANA MINN MICHIGAN WYOMING ** 120 SPDT Astronomic 1847AW 52005 120 SPDT 7 Day WITH RESERVE POWER 1847AL 52006 120 SPDT 24 Hour 1847AZL* ** 120 SPDT Astronomic 1847AWL 52010 120 SPDT 7 Day Replacement Trippers For 24 hour models order #P49 for a pair ON/OFF per dial. Additional ON/OFF trippers per dial order #P47. 3 omitting screws #53005 supplied. 7 day models order #P69 for 7 pairs of ON/OFF trippers. Replacement Motor #101(120V) & #201 (208-277V). For “L” models #36 (120V) *Add degrees latitude to complete number (18, 30, 34, or 42). **Consult factory for UPC number. A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com MAINE WISCONSIN SOUTH DAKOTA IDAHO UTAH IOWA NEW YORK KANSAS 34° IND COLORADO PENNSYLVANIA OHIO KENTUCKY OKLAHOMA ARIZONA NEW MEXICO ARKANSAS TIMING MOTOR 120VAC, 60HZ L TENNESSEE MASS RHODE ISLAND CONNECTICUT DELAWARE MARYLAND VIRGINIA CLOSE COMMON N NEW JERSEY WEST VIRGINIA MISSOURI CALIFORNIA ON VT NH ILLINOIS NEVADA C MECHANICALLY-HELD CONTACTOR NEBRASKA 24 Hour 1847AZ* OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage. ELECTROMECHANICAL CONTROLS OUTPUT CONTACTS ON OPEN NORTH CAROLINA SOUTH CAROLINA MISS ALABAMA TEXAS ASTRONOMIC SCHEDULING: Turn ON at sunset and OFF at sunrise daily. OFF time can be set from 8:30PM to 2:30AM. Can be individually offset +/20 or 40 minutes from both sunset and OFF times. OFF ASTRONOMIC LATITUDE ZONES OFF GEORGIA LOUISIANA MOMENTARY PUSH BUTTON MEXICO 30° FLORIDA 18° HAWAII 18° PUERTO RICO SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a Momentary Contact time switch. Time switch shall have dial of the (24 hour with day omitting device) (Astronomic with day omitting device) (7 day calendar) type, which shall be suitable to operate mechanically-held contactor of maximum size. Terminal board shall enable fast and correct installation using screw terminals for up to #12AWG wire. Timing motor terminals shall be completely independent from momentary switching circuit. Spring driven reserve mechanism shall be provided sufficient to operate time switch controls at least 16 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve. Time switch shall include solid state circuit to provide a switch closure not in excess of two seconds on both ON and OFF contactor coil terminals at such times as are set on dial: these settings to be made with removable trippers which can be added and removed without tools (except the astronomic dial). Contactor coil circuits shall be suitable for 10 Amp @ 24-277 VAC, 360 VA. Enclosures shall be NEMA 1 surface (or see other mountings), with provision for positive padlocking. Time switch shall be TORK Model 1847AL, 1848A, (AZL), (AWL). TORK 42 W SERIES CONTACT RATINGS SPECIFICATIONS DIFFERENT SCHEDULES EACH DAY 7 DAY TIME SWITCH TYPE INPUT VOLTAGE: 120 or 208-277VAC, 60Hz, varies by model. Resistive TERMINAL RANGE: #8 - #14AWG. OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C). CALIFORNIA Title 24 APPLICATIONS ASHRAE 90.1 Heating Air conditioning Display lighting Ventilating systems Lighted signage Storefront lighting POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum. 40A 120VAC 40A Inductive 120, 277VAC single phase 20A Pilot Duty 120 -277VAC 1000VA Motor 120VAC 240 VAC 2HP 5HP ORDERING INFO CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 60Hz OUTPUT CONTACTS W100 30001 120 SPST 33001 120 ENCLOSURE TYPE WIRING DIAGRAMS W100 (SPST) W100 (SPST) SPDT M W200 W202 FEATURES 31001 31011 120 208-277 SCHEDULING: Minimum ON setting is 1 hour with a minimum OFF setting of 2 hours. Minimum 8 hours between 2 OFF settings. Models W400A and W402A offer minimum ON/OFF settings of 31⁄2 hours. 7 day calendar dial accommodates up to 2 pairs of ON/OFF trippers per day – 7 pairs are supplied. SKIP-A-DAY: Omit operations on any day. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF automatic operation then resumes. OPTIONAL RESERVE POWER: “L” models keep dial on time up to 24 hours during power outage. W222 W300 W300-O W302 34001 34011 32001 32003 32002 120 208-277 120 120 208-277 L Metal Indoor NEMA 1 L L L L XH N H LOAD 1 N 2 LOAD H N H LOAD 2 X 1 2 H L N DPDT 1 LOAD 2 L 5 L 4 5 L N H 3PST 3PST 35001 120 4PST W402A 35002 208-277 4PST Equipment (4PST) W400A Ground Equipment Ground LOAD LOAD Clock Motor Supply 3 5 6 7 L X 1 2 H 2 H B X LOAD 1 LOAD N N H N L LOAD B N N 2 3 5 LOAD LOAD N 4 L H 3 LOAD N 5 4 LOAD LOAD H N W202 (DPST) 1 2 3 4 4 MOTOR MOTOR MOTOR L 7 8 8 B H 1 L 6 H LOAD H 5 LOAD L LOAD A 2 W202MOTOR (DPST) A 2 X X M M A Motor1 Clock Supply LOAD A LOAD 1 L H H Metal Indoor NEMA 1 1 LOAD 1 H H 6 W400A (4PST) Metal Indoor/Outdoor NEMA 3 L LOAD N 3PST M 4 L 6 LOAD 2 3 L LOAD 3 L LOAD 2 X M W220 (DPDT) M M L X 1 W220 (DPDT) W120 (SPDT) W120 (SPDT) DPDT W400A H L Typical for 208-240VAC 1 X LOAD LOAD 1 X LOAD H 2 LOAD 2 LOAD Typical for 277VAC H Typical for 208-240VAC Typical for 277VAC B WITH RESERVE POWER W220L 39009 120 DPDT W222L 39010 208-277 DPDT W300L 39005 120 3PST W302L 39006 208-277 3PST W400AL 39007 120 4PST Supply Supply Metal Indoor NEMA 1 Replacement Trippers Order #P69 for 7 pairs of ON/OFF trippers except W400 series use #P69i. Replacement Motor #101 (120V) & #201 (208-277V). For W400 series units order #101i (120V) & #201i (208-277V). For “L” models order #36 (120V) and #46 (208-277V), except W400 series consult factory. A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com M M H W220 W300 (3PST) W300 (3PST) M M DPST DPST W200 (DPST) W200 (DPST) M TORK 43 40A Tungsten ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp. Other enclosures include metal Indoor/ Outdoor NEMA 3 with suffix "O" (see page 153 for enclosure dimensions). W120 ELECTROMECHANICAL CONTROLS 120 -277VAC single phase 120 -277VAC single phase General Purpose TIMING ACCURACY: Line frequency. CONTACT RATING VOLTAGE To Load(s) To Load(s) SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, TORK time switch of the 7 day type, powered by a self-starting synchronous motor, capable of being set for different ON/ OFF times each day of the week, to an operating accuracy of plus or minus 15 minutes of the desired time. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPDT, SPDT, 4PST as required). Removable ON/OFF trippers shall make possible automatic operation with a minimum ON period of one hour and a minimum of 2 hours between one OFF operation and the next ON. Models W400 and W402 offer minimum ON and OFF settings of 3.5 hours. Enclosure shall be NEMA 1 surface, finished in baked beige enamel, with combination 1⁄2” - 3⁄4” knock-outs on bottom and both sides. Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time switch shall be TORK Model W_ _ _ (to fit requirement). FOR RESERVE POWER (Add suffix L): Spring-driven reserve shall be provided sufficient to operate the Time Switch contacts at least 24 hours after power failure (16 hour reserve power on 4PST models). On restoration of power, time switch shall transfer to synchronous motor driven and automatically rewind reserve power unit. TORK 44 LOAD T900 SERIES INPUT VOLTAGE: 120 or 208-277VAC, 60 Hz, varies by model. TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG. APPLICATIONS TYPE VOLTAGE CONTACT RATING General Purpose 120/277VAC 20A Motor 120VAC 240VAC 1HP 2HP OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C). CALIFORNIA Title 24 ASHRAE 90.1 Parking lot lighting HVAC Display lighting Security lighting Lighted signage Storefront lighting CONTACT RATINGS SPECIFICATIONS PHOTOELECTRIC & 7 DAY CONTROL COMBO DIFFERENT SCHEDULES EACH DAY RESERVE POWER STANDARD 2 & 3 CIRCUIT LIGHTING CONTROL CENTERS POWER CONSUMPTION: 5 watts maximum. ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp. Other enclosures include cover for access to by-pass switches with suffix "E" or Indoor/Outdoor NEMA 3 metal with suffix "O" (see page 153 for enclosure dimensions). Optional "E" cover Model 2101 supplied with unit. WIRING DIAGRAMS T930L T930L T920L T920L ONLYCIRCUITS CIRCUITS1 1AND AND2 2ARE AREINCLUDED INCLUDEDININT920L T920L ONLY ORDERING INFO FEATURES CATALOG NO. SCHEDULING: CIRCUIT 1: ON automatically at dusk, OFF at individual preset times each day, including skipping days when desired. Unit can be set to turn ON before dawn for early morning lighting. CIRCUIT 2: ON at dusk, OFF at dawn automatically, daily. CIRCUIT 3: Individual daily ON and OFF settings at desired times, including skipping any desired day or days Minimum ON is setting 1 hour with a minimum OFF setting of 2 hours. Minimum 8 hours between 2 OFF settings. 7 day calendar dial will accommodate up to 2 pairs of ON-OFF trippers per day – 7 pairs are supplied. SKIP-A-DAY: Omit operations on any day. UPC CODE INPUT SUPPLY (VAC) 60Hz 41033 120 2 SPDT T920L-E 41034 120 2 SPDT T920L-O 41035 120 2 SPDT T930L 41055 120 3 SPDT T930L-E 41056 120 3 SPDT T930L-O 41057 120 3 SPDT Metal Indoor NEMA 1 Metal Indoor NEMA 1 with switch access Metal Indoor/outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 with switch access Metal Indoor/outdoor NEMA 3 ON ON OFF OFF ON ON OFF OFF AUTO AUTO AUTO AUTO SWITCH TIMETIME SWITCH OFF OFF ON ON MM C C NOTE: NOTE: Contacts 7-12 Contacts 7-12 unpowered. areare unpowered. RELAY RELAY PHOTOELECTRIC PHOTOELECTRIC CONTROL CONTROL ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF AUTO AUTO AUTO AUTO AUTO AUTO NOTE: NOTE: Contacts 4-12 Contacts 4-12 unpowered. areare unpowered. RELAY RELAY C C PHOTOELECTRIC PHOTOELECTRIC CONTROL CONTROL MM CONTACTOR CONTACTOR CONTROL CONTROL CIRCUIT LINELINE CIRCUIT RED RED WHITE WHITE BLACK BLACK L1 L1 OPEN CLOSEOPEN LINELINE CLOSE 1 1 CONTACTOR CONTACTOR CONTROL CONTROL CIRCUIT CIRCUIT 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 H 120V H 120V N N 60C 60C LINELINE TIME TIME SWITCH SWITCH TO DAWN SAFETY LIGHTS DUSKDUSK TO DAWN SAFETY LIGHTS (PHOTOCELL - PHOTOCELL (PHOTOCELL ON - ON PHOTOCELL OFF) OFF) NEU.NEU. OPEN OPEN CLOSE CLOSE H 120V H 120V N N 60C BLACK 60C BLACK LINELINE WHITE WHITE RED RED 2 2 L1 L1 LINELINE OPEN OPEN OPENLINELINE OPEN CLOSE CLOSE CLOSE CLOSE 3 3 1 1 TO DAWN SAFETY LIGHTS DUSKDUSK TO DAWN SAFETY LIGHTS (PHOTOCELL - PHOTOCELL (PHOTOCELL ON - ON PHOTOCELL OFF) OFF) 2 2 NEUNEU OPEN OPEN CLOSE CLOSE LOAD LOAD LOAD LOAD #P69 for 7 pairs of ON/OFF trippers. #36 (120V) #66061 RESERVE POWER: Standard feature on all models keep dial on time up to 24 hours during power outage. NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads. TORK 45 ENCLOSURE TYPE OUTPUT CONTACTS MANUAL BY-PASS SWITCHES: Single pole, 20 Amps – one per circuit. Factory pre-wired to terminal strip. ON/OFF/AUTO positions for each circuit is independent – will not disturb automatic settings. ELECTROMECHANICAL CONTROLS MANUAL CONTROLS MANUAL CONTROLS MANUAL CONTROLS MANUAL CONTROLS T920L Replacement Trippers Replacement Motor Replacement Bypass Switch ALL3 3CIRCUITS CIRCUITSARE AREINCLUDED INCLUDEDININT930L T930L ALL A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com SPECIFICATION WRITER’S GUIDE T900 SERIES – Furnish and install, where shown, a TORK Photo/Time Control of the 7 Day Calendar dial type, which shall be suitable to operate mechanicallyheld contactor(s). Photo/Time Control shall be pre-wired to a central terminal block which provides connecting terminals for Photocontrol and independent contactor control circuit(s). Time switch shall function to prevent energization of lighting for preset periods each day. Time switch dial shall permit different ON/OFF settings for each day of the week, with provision for omitting selected days. Control shall include pre-wired manual switching for each contactor circuit specified. Enclosure shall be NEMA 1 surface. Photocontrol to be remotely installed in appropriate outside location. It shall be fully temperature compensated and shall provide for time delay of at least 15 seconds to prevent false switching. Photocontrol shall operate control center to energize whenever natural lighting falls below 1.5 - 5.5 foot candles turn on. Spring driven reserve timing motor shall be provided sufficient to operate time switch controls at least 24 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit. FOR DUSK-TO-DAWN LIGHTS: Control shall provide additional contactor circuit to above specifications except that it shall be responsive to Photocontrol only. Tork Model T-920L or equal. FOR PRESET ON/PRESET OFF: Control shall provide for additional contactor circuit to above specification except that it shall be responsive to time switch only. Tork Model T-930L. TORK 46 TW SERIES INPUT VOLTAGE: 120 or 208 - 277VAC, 60Hz, varies by model. TYPE VOLTAGE CONTACT RATING General Purpose 120/277VAC 20A Motor 120VAC 240VAC 1HP 2HP TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG. CALIFORNIA Title 24 OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C). ASHRAE 90.1 APPLICATIONS Heating Air conditioning Display lighting Ventilating systems Lighted signage Storefront lighting CONTACT RATINGS SPECIFICATIONS DIFFERENT SCHEDULES EACH DAY MANUAL BYPASS SWITCHES RESERVE POWER STANDARD 7 DAY TIME SWITCH POWER CONSUMPTION: 5 watts maximum. Optional "E" cover ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions). WIRING DIAGRAMS MANUAL CONTROLS MANUAL CONTROLS ON ON OFF ON AUTO ORDERING INFO FEATURES CATALOG NO. UPC CODE OUTPUT CONTACTS SCHEDULING: Minimum ON setting is 1 hour with a minimum OFF setting of 2 hours. Minimum 8 hours between 2 OFF settings. 7 day calendar dial accommodates up to 2 pairs of ON-OFF trippers per day – 7 pairs are supplied. TW-220L 39013 120 DPDT TW-220L-E 39021 120 DPDT TW-222L 39014 208-277 DPDT SKIP-A-DAY: Omit operations on any day. TW-300L MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. MANUAL BY-PASS SWITCHES: Single pole, 20 Amps – one per circuit. Factory pre-wired to terminal strip. ON/OFF/AUTO positions for each circuit is independent – will not disturb automatic settings. TW-302L Replacement Trippers Replacement Motor Replacement Bypass Switch 39016 120 3PST 208-277 3PST A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com 1 2 1 #36 (120V) & #46 (208-277V) #66061 3 ON 5 4 5 AUTO 6 6 NOTE: Switching contacts NOTE: are unpowered Switching contacts are unpowered OFF OFF AUTO 7 9 8 7 9 8 LINE LOAD LINE LINE LOAD LOAD LINE N H N H TW300L TW300L When single line source is When source is used, single jumperline terminals used, jumper terminals 1-5-7-9 and connect all com1-5-7-9 and connect2all commons to terminals and 3. mons to terminals 2 and 3. LOAD LINE LOAD LINE LOAD MANUAL CONTROLS MANUAL CONTROLS ON OFF ON 1 2 1 H 3 4 OFF TW220L TW220L OFF AUTO AUTO TIME SWITCH TIME SWITCH 2 4 3 M M ON ON OFF AUTO AUTO 5 5 6 6 7 7 8 8 CONTACTOR CONTROL CONTACTOR CIRCUIT 9 CONTROL CIRCUIT 9 N H NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads. TORK 47 Metal Indoor NEMA 1 Metal Indoor NEMA 1 with switch access Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Order #P69 for 7 pairs of ON/OFF trippers. RESERVE POWER: Standard feature on all models keep dial on time up to 24 hours during power outage. ELECTROMECHANICAL CONTROLS ENCLOSURE TYPE M ON OFF OFF AUTO AUTO TIME SWITCH TIME SWITCH 2 4 3 M INPUT SUPPLY (VAC) 60Hz 39015 ON OFF AUTO N CONTACTOR CONTROL CONTACTOR CIRCUIT CONTROL CIRCUIT COMMON OPEN COMMON CLOSE OPEN CLOSE COMMON COMMON OPEN CLOSE OPEN Wiring shown is for mechaniWiring shown is for mechanically-held contactors. Use cally-held contactors. CLOSE terminal onlyUse for magCLOSE terminalcontactors only for magnetically-held and netically-held contactors and to control direct loads not toexceeding control direct loads not 2000 watts. exceeding 2000 watts. CLOSE SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch of the 7 day type, capable of being set for different ON/OFF times each day of the week, to an operating accuracy of plus or minus 15 minutes of the desired time. The time switch shall be powered by a self-starting synchronous motor with spring-driven reserve, which shall be sufficient to operate the time switch contacts at least 24 hours after power outage. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit. Time switch shall provide for automatic operation with a minimum of one hour between an ON/OFF operation with minimum of four ON/OFF operations per day. ON/OFF operations shall be accomplished by removable ON/OFF trippers on the dial. Time switch contacts shall be capable of carrying a minimum 20 amperes per pole continuously at 277 volts and shall be DPDT or 3PST. Manual switches shall be provided as an integral part of the time switch, one for each pole, and shall permit manual switching to maintained ON or OFF positions until manually returned to AUTOMATIC position. Terminal strip shall be capable of receiving #10AWG wires. Enclosure shall be NEMA 1 surface type, finished in beige enamel, and with 1⁄2” - 3⁄4” combination knock-outs on bottom, both sides and top. Provision shall be made for positive padlocking. (Specify “E” door for manual switches to be accessible when case is locked). Shall be TORK Model TW (to fit switch requirement) or equal in general purpose NEMA 1, (general purpose metal) or (Indoor/Outdoor NEMA 3) enclosure. TORK 48 TZ SERIES CONTACT RATINGS SPECIFICATIONS MANUAL BYPASS SWITCHES RESERVE POWER STANDARD ASTRONOMIC TIME SWITCH INPUT VOLTAGE: 120 or 208 - 277VAC, 60Hz, varies by model. TYPE VOLTAGE CONTACT RATING General Purpose 120/277VAC 20A Motor 120VAC 240VAC 1HP 2HP TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG. OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C). CALIFORNIA Title 24 APPLICATIONS ASHRAE 90.1 POWER CONSUMPTION: 5 watts maximum. Schools Industrial yards Shop windows Parking lots Highway signs Bridges ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp and for some models enclosures is Indoor/Outdoor NEMA 3 metal with suffix "O" (see page 153 for enclosure dimensions). WIRING DIAGRAMS ASTRONOMIC LATITUDE ZONES 45° 42° ORDERING INFO FEATURES SCHEDULING: Turn ON at sunset and OFF at sunrise daily. OFF time can be set from 8:30PM to 2:30AM. Can be individually offset +/- 20 or 40 minutes from both sunset and OFF times. Available from 18° - 45° northern latitudes. SKIP-A-DAY: Omit operations on any day with a 7 spoke wheel marked with days of the week. 3 omitting screws included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. MANUAL BYPASS SWITCHES: Single pole, 20 Amps - one per circuit. Factory pre-wired to terminal strip. ON/OFF/AUTO positions for each circuit is independent, will not disturb automatic settings. CATALOG NO. TZ-220L* TZ-220L-O* UPC CODE ** ** INPUT SUPPLY (VAC) 60Hz 40° OUTPUT CONTACTS 120 DPDT 120 DPDT TZ-222L* ** 208 - 277 DPDT TZ-300L* ** 120 3PST TZ-300L-O* TZ-302L* Replacement Motor Replacement Bypass Switch ** ** 120 3PST 208 - 277 3PST Metal Indoor NEMA 1 Metal Indoor/outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor/outdoor NEMA 3 Metal Indoor NEMA 1 34° NOTE: Switching contacts NOTE: are unpowered Switching contacts are unpowered AUTO WASHINGTON OREGON NORTH DAKOTA MONTANA MINN WYOMING MAINE WISCONSIN SOUTH DAKOTA IDAHO AUTO MICHIGAN NH NEW YORK NEBRASKA ILLINOIS NEVADA UTAH IND COLORADO KANSAS PENNSYLVANIA OHIO KENTUCKY ARIZONA NEW MEXICO ARKANSAS TENNESSEE RHODE ISLAND CONNECTICUT VIRGINIA DELAWARE MARYLAND M 2 1 3 5 4 5 6 6 7 7 9 8 LINE LOAD LINE LINE LOAD LOAD LINE LINE LOAD LOAD LINE LOAD 9 8 N H N H NORTH CAROLINA SOUTH CAROLINA MISS ALABAMA TEXAS 1 MASS NEW JERSEY WEST VIRGINIA MISSOURI CALIFORNIA OKLAHOMA M VT IOWA TIME SWITCH TIME 2 SWITCH 4 3 GEORGIA LOUISIANA 30° TZ300L TZ300L When single line sourcesingle is used, When line jumperis terminals source used, 1, 5, 7,terminals 9 and connect jumper 1,all5,commons 7, 9 and toconnect allterminals commons2 and to 3. terminals 2 and 3. MEXICO FLORIDA 18° HAWAII MANUAL CONTROLS 18° PUERTO MANUAL CONTROLS RICO M 1 1 H H M TIME SWITCH TIME 2 SWITCH 4 3 2 3 4 5 5 6 6 7 7 8 8 9 9 N N CONTACTOR CONTROL CONTACTOR CIRCUIT CONTROL CIRCUIT CONTACTOR CONTROL CONTACTOR CIRCUIT CONTROL CIRCUIT COMMON OPEN COMMON CLOSE OPEN COMMON CLOSE OPEN COMMON CLOSE OPEN CLOSE TZ220L TZ220L Wiring shown is for mechanically Wiring shown isheld for contactors. Use mechanically heldCLOSE terminal only contactors. Usefor CLOSE magnetically held terminal only for contactors and magnetically heldto control direct contactors and loads to not exceeding control direct2000 loadswatts. not exceeding 2000 watts. #66061 *Add degrees latitude to complete number (18, 30, 34, 38, 40, 42, or 45). **Consult factory for UPC number. NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads. TORK 49 38° For "L" models #36 (120V) & #46 (208-277V) RESERVE POWER: Standard feature on all models keep dial on time up to 24 hours during power outage. ELECTROMECHANICAL CONTROLS ENCLOSURE TYPE MANUAL CONTROLS MANUAL CONTROLS A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch with Astronomic dial and day-omitting device, and a 3-way manual switch for each circuit. The time switch shall be powered by a self-starting synchronous motor with spring-driven reserve, which shall be sufficient to operate the time switch contacts at least 16 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve. ON operation shall occur automatically at sunset in (city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of adjustability of 20 or 40 minutes before or after sunset and sunrise. Time switch contacts shall be capable of carrying a minimum of 20 amperes per pole continuously at 277 volts and shall be DPST (3PST). Manual switches shall be provided as an integral part of the time switch, one for each pole, and shall permit manual switching to maintained ON or OFF positions until manually returned to AUTOMATIC position. Terminal strip shall be capable of receiving #10AWG wires. Enclosure shall be NEMA 1 surface type, finished in beige enamel, and with 1⁄2” - 3⁄4” combination knock-outs on bottom, both sides and top. Provision shall be made for positive padlocking. (Specify “E” door for manual switches to be accessible when case is locked). Time switch shall be TORK Model TZ-___ (to fit requirement). TORK 50 DIGITAL TIME SWITCHES FEATURES QUICK LOOK DTU40 DTWH40 E-PB E EW EWZ DG DGM DZS DTS DWZ Page No. 55 55 57 57 59 61 63 63 65 67 69 Number of Channels 1 1 1 1 or 2 1 or 2 1 or 2 1 or 2 1 1, 2, or 4 1, 2, or 4 20 (140) 20 20 20 56 56 99 ON/OFF Set Points 7 pair (98) 7 pair (98) DW DZM ELC71/72 ELC74/78/712 Page No. 69 71 73 1 Number of Channels 2 2 99 99 ON/OFF Set Points 99 99 7/365 day 7/365 day 7/365 day LIGHTING CONTROLS CYCLE - SIGNAL TIMER DGU DGUM DGLC DLC400 DG DGS DIN 75 79 79 79 81 85 85 89 1 or 2 4, 8, or 12 1 1 1 or 2 4 1 or 2 1 1 or 2 128 128 56 56 56 99 56 56 8 pair 3 pair/ch 7/365 day 7/365 day 24 Hour 7 Day 7 Day 365 Day/7 Day Scheduling 7 day 7 day 24 hour 24 hour 7 day 7 day Automatic Daylight Savings Adjustment Manual Manual Yes Yes Yes Yes Yes Yes Yes Yes Yes Automatic Daylight Savings Adjustment Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Leap Year Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 24 24 24 Individual Holiday Schedules 24 24 26 26 10 10 Yes Yes Yes Yes Leap Year 7/365 day 7/365 day ENERGY/LIGHTING CONTROLS Individual Holiday Schedules Block Holiday 9 9 Season Scheduling Block Holiday 4 Astronomic (Sunrise/Sunset) Yes 365 Day/7 Day Scheduling 7/365 day 7/365 day 4 Yes Yes Season Scheduling 4 Astronomic (Sunrise/Sunset) Yes 7/365 day 7/365 day 7/365 day 7/365 day 24 9 9 9 4 Yes Yes Yes Photosensor Input Photosensor Input Yes Yes Yes Yes Yes Yes Remote Override Input Remote Override Input Yes Yes Yes Yes Yes Yes User Defined Input User Defined Input Yes Yes Signal/Pulse Duration Yes Yes Yes Yes Yes Yes Signal/Pulse Duration Yes Momentary for Contactors Option Option Option Yes Yes Momentary for Contactors Duty Cycle Duty Cycle 31 Day Cycle 31 Day Cycle Yes Yes Yes Manual Override Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Manual Override Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Clock Format AM/PM AM/PM AM/PM AM/PM AM/PM AM/PM 12/24 12/24 12/24 12/24 12/24 Clock Format 12/24 12/24 12/24 12/24 12/24 12/24 12/24 12/24 12/24 12/24 AM/PM 7 day Super Capacitor 7 day Super Capacitor Power Outage Backup Permanent Permanent Permanent Schedule Retention without power Yes Yes Power Outage Backup Schedule Retention without power Rechargeable Rechargeable 4 day Super 4 day Super 4 day Super 4 day Super 7 day Super 7 day Super 7 day Super Battery Battery Capacitor Capacitor Capacitor Capacitor Capacitor Capacitor Capacitor Battery Battery Staggered Start Permanent Permanent Yes Yes Permanent Yes Permanent Permanent Permanent Yes Yes Yes Memory Module Computer Programming Software Output Contacts: Amps Resistive or General Purpose Staggered Start Yes Memory Module Yes Computer Programming Software Output Contacts: Amps Resistive or General Purpose Contact Type: Dry Unpowered 40A 40A 30A 40A 40A 40A 20A 20A 30A/20A 30A/20A 30A Contact Type: Dry Unpowered Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Voltage Input AC 120/208240/277 120/208240/277 120 120-277 120-277 120-277 120-277 120-277 120/208240/277 120/208240/277 120/208240/277 Low Voltage Input (select models) TORK 53 12VDC 24VAC Voltage Input AC Low Voltage Input (select models) 7 day Super 7 day Super 7 day Super Capacitor Capacitor Capacitor Permanent Permanent Yes Yes 2 day Capacitor 7 day Super 7 day Super 7 day Super 1 year battery Capacitor Capacitor Capacitor Capacitor Battery Permanent Permanent Yes Yes Yes Yes 6 month battery 7 day Super 7 day Super Capacitor Capacitor Permanent Permanent Permanent Yes Yes Yes Permanent Yes Yes 8 year battery Battery Yes Yes Yes Yes 30A 30A 20A 20A 20A 20A 20A 30A 20A 20A 16A Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 24/120/208 240/ 277 120-277 120-277 120-277 120/208240/277 120-277 120-277 120 12VDC 24VAC 24VAC 120/208- 120/208- 120/208-240/ 240/277 240/277 277 24VAC All Models TORK 54 DT SERIES NEW! AUTOMATIC VOLTAGE DETECTION 24 HOUR OR 7 DAY HOUR TIME SWITCH MORE WIRING SPACE! NEW! INPUT VOLTAGE: 120/208-240/277 VAC, 50/60 Hz (auto detection). DTWH40 is 120/240VAC (auto detection). TYPE VOLTAGE Resistive TERMINAL RANGE: #8 - #18AWG. OPERATING TEMPERATURE: -31°F to 116°F (-35°C to +47°C). APPLICATIONS DTU40 Pumps, motors, fans Signs and lighting Water heaters Heating and air conditioning CONTACT RATINGS SPECIFICATIONS POWER CONSUMPTION: 6VA Max. ENCLOSURE: DTU40 polycarbonate Indoor/ Outdoor NEMA 3R. DTWH40 polycarbonate indoor NEMA 1 enclosure with clear cover. Both with lockable hasp (see page 153 for enclosure dimensions). DTU40 DTWH40 DTWH40 Water Heaters This timer turns OFF when rates are high and turns OFF when no one is home. SAVE ENERGY! 120-277VAC 40A 30A Inductive 120-277VAC 30A 15A Ballast 120VAC 277VAC 30A 20A 10A 10A Tungsten 120VAC 15A 120VAC 240VAC 120VAC 240VAC 1HP/30FLA/90LRA 2HP/20FLA/60LRA 720VA 720VA Resistive 28VDC 20A Max above 104° 120-277VAC 30A Pilot duty 1⁄4HP/12FLA/30LRA 1⁄2HP/12FLA/33LRA 290VA 260VA Typical Wiring Diagram, Application Typical Wiring Diagram, 120120/277VAC VAC Application TIMER SUPPLY N NC CATALOG NO. UPC CODE TIMER SUPPLY (VAC) 60Hz NO. OF CHANNELS DRY CONTACTS (UNPOWERED) L N DTU40 24004 120/208-240/277 1 DPDT DTWH40 24005 120/240 1 DPDT H NC N NO C LOAD L N NC NO C WIRING DIAGRAMS L1 MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. C N L Typical Wiring Diagram, 208-240 VAC Application TIMER SUPPLY DAYLIGHT SAVING: Manual button push for one hour adjustment. NO LOAD ORDERING INFO SCHEDULING: 7 ON & OFF pairs of set points for individual programs on each day of the week. Minimum setting is 1 minute. NC DTU40 H FEATURES NO Motor Avoid utility peak rates Turn off when not needed RATING NC NO C LOAD L2 L1 L2 DTWH40 DTU40 Typical Wiring120 Diagram, 120VAC Typical Wiring Diagram, 120/277VAC Application Typical Wiring Diagram, VAC Application EXTERNAL MANUAL OVERRIDE: DTWH40 only on clear door. Override without opening case. TIMER SUPPLY H N TIMER SUPPLY NC NO C NC LOAD RANDOM MODE: Varies ON and OFF times to create "lived-in" look when away. L CLOCK FORMAT: AM/PM. Typical Wiring Diagram, Application Typical Wiring Diagram, 120120/277VAC VAC Application N N NO C H L N L TIMER SUPPLY H N NC NO C L N N L2 NO C LOAD L N L Typical Wiring Diagram, 208-240 VAC Application TIMER SUPPLY NC NO C NC NO C H N NC NO C LOAD L1 NC LOAD Typical Wiring 208-240 VAC Application Typical Diagram, Wiring Diagram, 240VAC POWER OUTAGE BACKUP: Battery retains time and schedule. N LOAD L1 NC NO C LOAD L2 L1 L2 L1 L2 DTWH40 Typical Wiring120 Diagram, 120VAC Typical Wiring Diagram, 120/277VAC Application Typical Wiring Diagram, VAC Application DIGITAL CONTROLS TORK 55 TIMER SUPPLY H A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com N NC NO C LOAD L N N NC NO C LOAD L N L TORK 56 E & E-PB SERIES CONTACT RATINGS SPECIFICATIONS BACK-UP WITHOUT BATTERY, ECO FRIENDLY! MULTIPURPOSE CONTROLS 1 OR 2 CHANNEL 24 HOUR TIME SWITCH INPUT VOLTAGE: E SERIES 120 - 277VAC, 50/60Hz (automatic detection). E-PB 120VAC, 50/60Hz. APPLICATIONS TERMINAL RANGE: #8 - #16AWG. E101B Signs Air conditioning Lighting Sump pumps Ventilating fans OPERATING TEMPERATURE: -40° to +149°F (-40° to +65°C). 1 4CONSUMPTION: 6VA Max. 3 POWER ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R is standard with lockable hasp (see page 153 for L N N 120/277VAC enclosure dimensions). 2A 120VAC 5A 720VA 720VA 720VA 120-277VAC 470VA 1HP 1HP 11⁄2HP 2HP 1HP 11⁄2HP 2HP 120VAC 240VAC 1HP 2HP 30A 30A 28VDC 20A 30A Inductive 120-277VAC 40A 30A 30A Ballast 120VAC 208-277VAC 30A 20A 30A 20A Tungsten 120VAC 15A 120-277VAC Pilot Duty E101B 3 2 120VAC TIMER 5 SUPPLY LOAD 208VAC 240-277VAC Motor4 LOAD LOAD L 15A 30A SPDT 1 10A 10A 30A 12A 30A 12A 20A 6A 40A TIMER SUPPLY Resistive N N N 1 28VDC SPST 11 2HP ⁄ 2HP 2 3 120/277VAC E101PB VOLTAGE RATING NO 120/240VAC 277VAC 120/240VAC 277VAC 120VAC 277VAC 120-277VAC SPST 2 E120B RATING NO NC VOLTAGE General Purpose E120B TIMER SUPPLY E101B, E103B, E201B RATING NO TYPE TIMING ACCURACY: Line Frequency. 4 30A E120 TIME SUPP 1 LOAD L N N L 120/277VAC WIRING DIAGRAMS E103B DPST TIMER SUPPLY E101B 1 FEATURES SCHEDULING: 20 ON/OFF set points repeat each day. Minimum setting 1 minute. E101B UPC CODE 82401 INPUT SUPPLY (VAC) 50/60Hz 120-277 NO. OF CHANNELS OUTPUT DRY CONTACTS 1 E103B 82411 120-277 1 82406 120-277 1 LEAP YEAR: Automatic Compensation. E201B 82466 120-277 2 E101PB 82401 120-277 L 1N N 2 3 L TIMER SUPPLY L 1 4 N E101B 2 3 4 N 5 N 3 1 2 TIMER SUPPLY SPST LOAD 1 N 120/277VAC 2 N L 6 TIMER SUPPLY 1 LOAD E101PB DPST SPDT TIMER SUPPLY 1 3 2 N L 2 LOAD 4 3 4 LOAD 5 TIMER SUPPLY 5 6 1 2 L N 4 N 5 N 3 4 5 120/277VAC N 2 3 4 5 6 PULSE OFF E201B E201B ONLY: UNIT MUST BE CONFIGURED FOR TIMER MOMENTARY OPTION. 2 L N N 3 TIMER SUPPLY LOAD 1 3 CH 1 SP 4 3 2 LOAD N 120VAC N 6 TIMER SUPPLY PULSE ON 1 L E201B L L2 208 OR 240VAC CH 1 SPST LOAD LOAD 1 2 L N MOMENTA C 3 4 CH 2 SPST SUPPLY N L 2 SPST 120/277VAC LOAD N N L DPST TIMER SUPPLY MOMENTARY CONFIGURATION CH 1 L1 6 N 120/277VAC 1 LOAD N L N N N 120/277VAC 4DPST 5 LOAD LOAD 3 L 1 120/277VAC L N N TIMER SUPPLY LOAD POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 4 days of real time backup. 5 6 E103B 4 3 LOAD 4 120/277VAC TIMER SUPPLY LOAD L2 3 2 L N SPDT L1 208 OR 240VAC SPST 1 2 E120B E103B LOAD E120B SPST SPDT TIMER SUPPLY 1 1 DPST CH 2 SPST LOAD DPST TIMER SUPPLY CH 1 SPST LOAD 120/277VAC SPST L CLOCK FORMAT: AM/PM. 4 5 6 N L N 120/277VAC LOAD PULSE O E201B O BE CON MOMEN 120/277VAC 120/277VAC DPST TIMER SUPPLY 1 E201B 1 2 4 3 5 6 LOAD L LOAD N N N L 120/277VAC DPST TIMER SUPPLY 1 2 3 4 5 6 L2 208 OR 240VAC A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com LOAD 2 3 4 5 6 CH 1 CH 2 SPECIFICATION SPST SPST WRITER’S MOMENTARY CONFIGURATION TIMER GUIDE CH 1 SUPPLY TIMER E100B only – 1. Furnish and install a TORK digital time switch with (40 Amp SPST contacts, model E101B,E201B) (40 Amp DPST contacts, model E103B) (30 Amp SPDT SUPPLY L1 L2 contacts, model E120B). 2. Unit shall be capable of 20 set points. 3. Unit shall repeat the same schedule each day. 4. (Model E201B ONLY) Unit shall be capable of being LOAD 208 OR 240VAC 1 2 3 4 5 6 4 maintained 5 1 2 6 a 1 channel momentary 5. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 6. Unit shall program in AM/PM a32 channel or LOAD LOAD format. 7. Unit shall have LCD display. 8. Unit shall have permanent schedule retention. 9. Unit real time clock shall be retained by super capacitor for 100 hours in a power failure. 10. Unit shall be capable of manual override ON or OFFL either to thePULSE nextON scheduled event or permanently. 11. Unit shall have a NEMA 3R Indoor/Outdoor PULSE OFF N N L 12. Unit Nshall have Load Status indication. 13. Unit shall have Power Failure indication. 14. To order specify TORK Model E101B (E103B) (E120B) L N plastic enclosure. 120/277VAC E201B ONLY: UNIT MUST 120/277VAC BE CONFIGURED FOR MOMENTARY OPTION. (E201B). TIMER SUPPLY L1 DPST TIMER SUPPLY E103B MOMENTARY OPTION: For mechanically held contractors: Model E201B only. Configure with simple jumper change for single-channel momentary operation. TORK 57 TIMER SUPPLY 120/277VAC E120B DIGITAL CONTROLS E201B SPST 6 5 LOAD DAYLIGHT SAVING: Automatic adjustment (can be omitted). MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. 4 3 2 ORDERING INFO CATALOG NO. 120/2 1 2 L N MOMENTARY CONFIGURATION CH 1 3 4 PULSE ON 5 6 PULSE OFF TORK 58 EW SERIES AUTOMATIC DST - SAVES TIME CHANGES TWICE A YEAR MULTIPURPOSE CONTROL 1 OR 2 CHANNEL 7 DAY TIME SWITCH SPECIFICATIONS CONTACT RATINGS TIMING ACCURACY: Line Frequency. TYPE INPUT VOLTAGE: 120 - 277VAC, 50/60Hz (automatic detection). energy APPLICATIONS ASHRAE 90.1 Outdoor signs Lighting security Heating and air conditioning 40A 120-277 VAC 30A 30A Inductive 120-277VAC 40A 120-277 VAC 30A 30A Ballast 120VAC 208-277VAC 30A 20A 120VAC 208-277VAC 30A 20A 10A 10A Tungsten 120VAC 15A 120VAC 15A 2A Pilot Duty 120-277VAC 720VA 120-277 VAC 720VA 720VA Motor 120VAC 208VAC 240-277VAC SPST 1HP TIMER 120VAC 11⁄2HPSUPPLY 208VAC 2HP 240-277VAC 1HP 11⁄2HP 2HP 1HP 11⁄2HP 2HP Resistive 28VDC 30A 30A POWER CONSUMPTION: 6VA Max. ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R. EW101B Suffix -C plastic clear cover Indoor/Outdoor NEMAEW120B TIMER 3R. Suffix SPST -Y metal Indoor enclosure NEMA 1. All TIMER SUPPLY with lockable hasp (see page 153 for enclosure SUPPLY dimensions). 1 2 3 4 1 2 L N SPDT 3 LOAD 4 LOAD 5 EW101B 1 2 30A N N WIRING DIAGRAMS 120/277VAC ORDERING INFO FEATURES SCHEDULING: 20 ON & OFF set points for individual programs for each day of the week. Minimum setting is 1 minute. DAYLIGHT SAVING: Automatic (can be omitted). LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 4 days of real time backup. 1 CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 50/60Hz NO. OF CHANNELS EW101B 82431 120-277 1 SPST EW103B 82441 120-277 1 DPST EW120B 82436 120-277 1 SPDT EW201B 82467 120-277 2 SPST EW103B-C 82253 120-277 1 DPST 82255 120-277 1 L EW120B-Y EW201B-Y 82437 82261 82299 120-277 120-277 120-277 1 1 2 EW101B SPST TIMER SUPPLY 1 2 1 3 N 3 N 120/277VAC N L 1 CH 2 SPST 2 120/277VAC 3 4 LOAD PULSE OFF LOAD N N CH 1 1 2 3 4 5 1 2 N 120/277VAC PULSE ON L N N N DPST momentary configuration 3 EW103B 4 5 TIMER SUPPLY 6 1 2 DPST 1 4 3 LOAD CH 1 TIMER SUPPLY 5 2 3 N LOAD N L N L 4 5 6 6 120/277VAC N PULSE ON PULSE OFF EW201B ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION 120/277VAC N DPST TIMER SUPPLY CH 1 3 1 2 L1 L2 3 4 5 6 DPST TIMER SUPPLY 4 5 6 LOAD SPECIFICATION 1WRITER’S GUIDE 4 3 5 6 2 208 OR 240VAC EW SERIES – 1. Furnish and installON a TORKPULSE digital OFF time switch with (40 Amp SPST contacts, model EW101B, EW210B) (40 Amp DPST contacts, model EW103B) (30 Amp PULSE L N LOAD LOAD SPDT contacts, model EW120B). 2. Unit shall be capable of 20 set points. 3. Unit shall be capable of a different schedule each day of the week. 4. (Model EW201B ONLY) 120/277VAC EW201B ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION Unit shall be capable of being a 2 channel maintained or a 1 channel momentary. 5. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 6. L N N L N Unit shall program in AM/PM format. 7. Unit shall have LCD display. 8. Unit shall have permanent schedule retention. 9. Unit real time clock shall be retained by super 120/277VAC capacitor for 100 hours in a power failure. 10. Unit shall be capable of manual override ON or OFF either to the next scheduled event or permanently. 11. Unit shall have DPST TIMER a NEMA 3R Indoor/OutdoorSUPPLY plastic enclosure. 12. Unit shall have Load Status indication. 13. Unit shall have Power Failure indication. 14. To order specify TORK Model EW101B (EW103B) (EW120B) (EW201B). 1 2 L1 L2 3 4 5 6 6 208 OR 240VAC L N L EW103B TIMER SUPPLY CH 2 SPST 5 LOAD momentary configuration CH 1 SPST N L2 120/277VAC EW201B 6 LOAD 208 OR 240VAC 5 EW201B ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION L 5 4 6 PULSE ON CH 2 SPST LOAD TIMER SUPPLY SPST TIMER 4 5 SUPPLY 2 4 LOAD 120/277VAC L1 momentary configuration TORK 59 2 3 2 120/277VAC CH 1 SPDT 1 L TIMER SUPPLY A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com 3 CH 1 4 N MOMENTARY OPTION: For mechanically held contractors: Model EW201B only. Configure with simple jumper change for single-channel momentary operation. DIGITAL CONTROLS L N EW120B EW201B TIMER SUPPLY SPDT SPST 2 1 PULSE OFF EW201B ONLY: UNIT MUST BE TIM SU 1 L CH 1 SPST LOAD momentary configuration DPST SPDT 1 EW 120 SUPPLY 4 N N EW201B TIMER TIMER SUPPLY 120/277VAC L EW120B-C 3 N SPDT DPST LOAD LOAD EW103B-Y 2 4 120/277VAC EW120B EW103B SPST CH 2 SPST CH 1 TIMER SPST SUPPLY L N 120/277VAC EW101B EW201B OUTPUT DRY CONTACTS N 3 28LOAD VDC LOAD L RATING NO NC 120-277VAC OPERATING TEMPERATURE: -40° to +149° (-40° to +65°C). CALIFORNIA Title 24 EW120B VOLTAGE General Purpose TERMINAL RANGE: #8 - #16AWG. responsible EW101B, EW103B, EW201B RATING VOLTAGE NO LOAD TORK 60 EWZ SERIES PREFERRED FOR OUTDOOR LIGHTING MULTIPURPOSE CONTROL 1 OR 2 CHANNEL, ASTRONOMIC 7 DAY TIME SWITCH SPECIFICATIONS CONTACT RATINGS TIMING ACCURACY: Line Frequency. TYPE INPUT VOLTAGE: 120 - 277VAC, 50/60Hz (automatic detection). energy APPLICATIONS ASHRAE 90.1 Outdoor signs Lighting security Heating and air conditioning 40A 120-277 VAC 30A 30A Inductive 120-277VAC 40A 120-277 VAC 30A 30A Ballast 120VAC 208-277VAC 30A 20A 120VAC 208-277VAC 30A 20A 10A 10A POWER CONSUMPTION: 6VA Max. Tungsten 120VAC 15A 120VAC 15A 2A ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R Pilot Duty 120-277VAC 720VA 120-277 VAC 720VA 720VA Motor 120VAC 208VAC 240-277VAC 1HPTIMER SUPPLY 11⁄2HP 2HP SPST 120VAC 208VAC 240-277VAC 1HP 11⁄2HP 2HP 1HP 11⁄2HP 2HP Resistive 28VDC 28 VDC 30A 30A is standard with lockable hasp (see page 153 forEWZ120 EWZ101 SPST enclosure dimensions). Suffix -MB without enclosure TIMER and includes mounting bracket. SUPPLY SPDT TIMER SUPPLY 1 2 3 4 1 2 3 LOAD 4 LOAD 5 LOAD L N N 120/277VAC L WIRING DIAGRAMS120/277VAC SCHEDULING: 20 ON & OFF set points for individual programs for each day of the week. Minimum setting is 1 minute. ASTRONOMIC: Adjustable 10° - 60° Northern or Southern latitudes. Can be individually offset +/- 1-240 minutes from both sunset and sunrise times. DAYLIGHT SAVING: Automatic (can be omitted). LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 50/60Hz 1 NO. OF CHANNELS 82470 120-277 1 SPST EWZ103 82473 120-277 1 DPST EWZ120 82471 120-277 1 SPDT EWZ201 82472 120-277 2 SPST 120-277 1 82269 120-277 1 DPST EWZ120-MB 82275 120-277 1 SPDT EWZ201-MB 82281 120-277 2 SPST TIMER SUPPLY 2 1 3 SPST EWZ103-MB SPST 2 1 L N CH 2 SPST POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 4 days of real time backup. MOMENTARY OPTION: For mechanically held contactors: Model EWZ201 only. Configure with simple jumper change for single-channel momentary operation. momentary configuration CH 1 TIMER SUPPLY TORK 61 3 4 LOAD PULSE OFF 1 N L1 5 2 3 4 5 2 3 TIMER SUPPLY L N PULSE ON L N CH 2 SPST LOAD N N DPST EWZ103 4 5 6 4 5 L2 1 2 4 3 LOAD CH 1 TIMER SUPPLY DPST 5 1 2 LOAD L N 3 N N L 4 5 6 6 120/277VAC L N N PULSE ON PULSE OFF EWZ201 ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION 120/277VAC DPST TIMER SUPPLY 1 2 3 4 5 6 6 L1 L2 4 3 5 6 1 2 SPECIFICATION WRITER’S GUIDE LOAD 208 OR 240VAC EWZ SERIES – 1. Furnish and install TORK digital time switch with (40 AMP contacts, models EWZ101, EWZ201) (40 Amp DPST contacts, model EWZ103) (30 AMP PULSE ON PULSE OFF LOAD LOAD L N contacts, model EWZ120). 2. Unit shall be capable of 20 set points. 3. Unit shall be capable of a different schedule for each day of the week. 4. Unit shall be have 120/277VAC EWZ201 ONLY: UNIT MUST BE CONFIGURED FOR1°MOMENTARY OPTION astronomic option adjustable from 60° northern or southern latitudes. 5. Unit shall be have astronomic option with offset up to 4 hours and 59 minutes, before or L N N L N after sunrise. 6. (Model EWZ201 ONLY) Unit shall be capable of being a 2 channel maintained or a 1 channel momentary. 7. Unit shall have automatic Daylight Savings 120/277VAC Time and Leap Year compensation. 8. Unit shall program in AM/PM format. 9. Display shall be of LCD type. 10. Unit shall have permanent schedule retention. 11. Unit DPST TIMER real time clock shall beSUPPLY retained by capacitor for 100 hours in a power failure. 12. Unit shall be capable of manual override ON or OFF either in the next scheduled event or permanently. 13. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 14. Unit shall have Load Status indication. 15. Unit shall have Power Failure indication. 16. To order1specify 4 3 Model EWZ101 5 (EWZ103) 6 (EWZ120) (EWZ201). 2 TORK 6 L2 PULSE OFF EWZ201 ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION TI SU 1 L 5 LOAD DPST 208 OR 240VAC 120/277VAC 3 208 OR 240VAC CH 1 EWZ103 L1 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com LOAD N TIMER SUPPLY 1 2 6 LOAD TIMER SUPPLY momentary configuration CH 1 SPST N 5 4 EW 120 CH 1 SPST 6 2 N momentary configuration CH 2 SPST SPST 120/277VAC EWZ201 4 LOAD LOAD N 1 EWZ201 ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION L 120/277VAC 3 TIMER SUPPLY SPDT CH 1 PULSE ON N 120/277VAC N CLOCK FORMAT: AM/PM. DIGITAL CONTROLS 3 2 L N 120/277VAC EWZ120 TIMER SUPPLY 4 5 N EWZ201 120/277VAC EWZ201 3 L 4 LOAD DPST SPDT CH 1 4 LOAD L 2 1 L N momentary configuration TIMER SUPPLY 3 SUPPLY 1 4 N 2 120/277VAC TIMER TIMER SUPPLY 120/277VAC EWZ101 1 30A N LOAD L 1 82263 3 OUTPUT DRY CONTACTS EWZ101 EWZ101-MB 2 EWZ101 EWZ120 EWZ103 SPST CH 2 SPST CH 1 TIMER SPST SUPPLY ORDERING INFO N N EWZ101 EWZ201 FEATURES RATING NO NC 120-277VAC OPERATING TEMPERATURE: -40° to +149° (-40° to +65°C). CALIFORNIA Title 24 EWZ120 VOLTAGE General Purpose TERMINAL RANGE: #8 - #16AWG. responsible EWZ101,EWZ103, EWZ201 RATING VOLTAGE NO LOAD TORK 62 DG100 SERIES MULTIPURPOSE CONTROLS 1 OR 2 CHANNEL 365/7 DAY TIME SWITCH HOLIDAY PROGRAMMING FOR MORE SAVINGS! NEW! SPECIFICATIONS CONTACT RATINGS TIMING ACCURACY: Line Frequency. TYPE VOLTAGE NO NC Resistive 24-277VAC 20A 10A Ballast 120 VAC 277 VAC 20A 10A Tungsten 120VAC 15A INPUT VOLTAGE: 120 - 277VAC, 50/60Hz (automatic detection). TERMINAL RANGE: #12 - #18AWG. APPLICATIONS OPERATING TEMPERATURE: -31° to +131°F (-35° to +55°C). CALIFORNIA Title 24 Pilot Duty POWER CONSUMPTION: 6VA Max. ASHRAE 90.1 Indoor/Outdoor lighting HVAC equipment School warning and other Traffic lights Water heaters in offices, churches and factories Motor ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R. Suffix -Y metal indoor enclosure NEMA 1. All with lockable hasp (see page 153 for enclosure Resistive 120VAC 240VAC 120VAC 240VAC 28VDC RATING 1HP 2HP 290VA 360VA 1⁄4HP 1⁄2HP 20A 10A 720VA dimensions). WIRING DIAGRAMS DGM100A DG200A ORDERING INFO CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 50/60Hz NO. OF CHANNELS OUTPUT CONTACTS SCHEDULING: 56 ON & OFF set points provide individual programs for each day of the week. Minimum setting is 1 minute. DG100A 82201 120-277VAC 1 DPDT DG200A 82209 120-277VAC 2 SPDT MOMENTARY CONTACT: DGM100A has 2 second contact closures for ON & OFF control of mechanically held contactors or latching relays. DGM100A 82210 120-277VAC 1 DGM100A-Y 82222 120-277VAC 1 SPDT Momentary SPDT Momentary FEATURES BLOCK HOLIDAY: 9 holiday blocks can be set for individual days or for duration of any number of days. DG100A DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM or 24 Hour format. SPECIFICATION WRITER’S GUIDE DG100/200A SERIES – 1. Furnish and install, where noted, a 1 (2) channel 7-day programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast loads at 277VAC. 4. Controller shall be capable fo 56 set points; separate scheduling for each day of the week with one minute resolution. 5. Controller shall have 365 day holiday capabilities with 9 block holidays for individual or duration of any number of days. 6. Controller shall be able to select USA Standard Daylight Saving, Standard time, or programmable dates. 7. Controller shall have automatic Leap Year correction. 8. Controller shall have Permanent Schedule Retention. 9. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 10. Controller shall be capable of Manual Override ON or OFF to the next scheduled event using 1 button for each channel. 11. Unit shall have NEMA Type 3R indoor/outdoor enclosure as standard. 12. To order specify TORK Model DG100A (DG200A). 13. To order momentary contact closure for latching contactor control specify DGM100A. POWER OUTAGE BACKUP: Permanent schedule retention is provided. Supercapacitor provides 7 days of real time back up. DIGITAL CONTROLS TORK 63 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 64 DZM200B DZS SERIES REMOVABLE MEMORY MODULE FOR COMPUTER PROGRAMMING! MULTIPURPOSE CONTROLS 1, 2 OR 4 CHANNEL 365 / 7 DAY ADVANCED TIME SWITCH SPECIFICATIONS N GND NO UPPER BOARD TIMER SUPPLY C ON L energy APPLICATIONS CALIFORNIA Title 24 HVAC equipment Horns and bells Interior lighting Electric motors Outdoor lighting and signs N PULSE ON 208-240V INPUT VOLTAGE: 120/208-240/277VAC, 50/60Hz. 277V N SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week at a minimum 1 minute apart. NO. OF CHANNELS DRY CONTACTS (UNPOWERED) DZS100BP 82182 120/208-240/277 1 DPDT DZS200BP ASTRONOMIC: Adjustable 10˚ - 60˚ Northern or Southern latitudes can be individually offset +/-1 to 240 minutes from both sunset and sunrise times. DZS400BP USB-MMP 82183 82184 120/208-240/277 120/208-240/277 2 120 4 Memory Module Programmer 82196 SPDT 82215 120/208-240/277 1 DPDT HOLIDAYS: 1 to 24 individual dates. DZS200BP-0 82227 120/208-240/277 2 SPDT SIGNAL/PULSE DURATION: 2 different settings per channel: 1-99 seconds. DZS200BP-12 82228 12VDC 2 SPDT DZS200BP-24 82229 24VAC 2 SPDT DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. 82230 120/208-240/277 4 SPDT NC 24-277VAC 30A 30A 24-277VAC 20A Ballast 120VAC 277VAC 30A 20A 10A 10A 120-277VAC 13A Tungsten 120-277VAC 15A 2A NO C NC L L LOAD N 277V GND NO Motor Load C NC NO C C N 120 208-240 120-277VAC Resistive 28VDC120V N 720VA 120 208-240277 30A L ON OFF C 12-277VAC 30A 1HP ON PULSE OFF OFF 720VA 720VA PULSE ON PULSE OFF N AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE 1HP L PULSE ON 208-240V 8A CH 2 120-277VAC 720VA 20A N MECHANICALLY HELD CONTACTORS OR LATCHING RELAYS LOAD NO NC N 277 CH 1 SPDT L 208-240V C TIMER SUPPLY Pilot Duty 120VAC CH 1 1HP 2HP 277V L LOADNC NO 1HP 2HP 208-277VAC NC CH 2 SPDT L WIRING DIAGRAMS AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE CH 4 SPDT CH 1 SPDT C 120VAC DZM200B N 120V CH 2 SPDT L LOAD 277V LOAD N NO C TIMER SUPPLY LOWER BOARD N NC NO C NC DPDT N 120 208-240 277 L 120V C 208-240V SUPPLY AC LINE INPUT TIMER SELECT PROPER TERMINALS 277V AND APPLY ONLY ONE VOLTAGE DZS100BP 120 L LOAD N NO NC C CH 3 SPDT LOAD N NO NC 208-240 277 UPPER BOARD 120V L 208-240V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE L LOAD 277V LOAD N CH 1 SPDT C TIMER SUPPLY DZS200BP 120 208-240 C C NO NC TIMER SUPPLY LOAD 277V MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. In signal mode, activates pulse. LOAD N N NC N NO C CH 2 SPDT NC NO C NC LOWER BOARD 120 208-240 277 L 120V L C L CH 1 SPDT N L NO LOAD N 277 208-240V NC L CH 2 SPDT NO NC CH 4 SPDT LOAD 120V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE GND NO N DZS400BP N DZS400BP-0 General Purpose PULSE OFF CH 2 SPDT N LOAD UPPER BOARD Includes software DZS100BP-0 N CH 3 SPDT N SEASONS: 1 to 4 with different daily schedules which can wrap around into the new year. DZS400BP RATING VOLTAGE NO NC 208-240 277 208-240V N SPDT PULSE ON NO C TIMER SUPPLY TIMER SUPPLY (VAC) 50/60Hz DZS100BP, DZS200BP RATING VOLTAGE NO NC TYPE MECHANICALLY HELD CONTACTORS OR LATCHING RELAYS ENCLOSURE: Noryl Indoor/Outdoor NEMA 3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All with lockable hasp (see page 153 for enclosure dimensions). DZS400BP DZS200BP UPC CODE CONTACT RATINGS LOAD 120V ® CATALOG NO. NC L CH 1 SPDT POWER CONSUMPTION: 5VA Max: DZS100/200BP. 6VA Max: DZS400BP. FEATURES OFF LOWER BOARD OPERATING TEMPERATURE: -40° to +158°F (-40° to 70°C). ORDERING INFO C ON PULSE OFF N TIMER SUPPLY AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE ASHRAE 90.1 NO C LOADL AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE responsible NC L 120 208-240277 120V DZS400BP TIMING ACCURACY: Line frequency. TERMINAL RANGE: #14-#16AWG for line input. #12-#16AWG load outputs. C OFF AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE LOAD 208-240V N 277V L LOAD N DPDT TIMER SUPPLY DZS100BP CLOCK FORMAT: AM/PM or Military time. POWER OUTAGE BACKUP: Permanent schedule retention with memory module. Supercapacitor provides 7 days of real time backup. C NO NC C NO NC SPECIFICATION WRITER’S GUIDE CH 1 CH 2 L DZS SERIES – 1. Furnish and install, where noted, a 4L (2) (1)LOAD channel digital time switch with portable Memory Module on front panel.SPDT 2. MemorySPDT Module shall be LOAD capable of being programmed at any one location and inserted into DZS100BP, 200BP, 400BP Series (with memory module socket) in any other remote location. N N C NO C NO NC 3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication of NC Memory Modules or DZS200BP individualized programs for multiple locations 4. Unit shall have copy feature: Can be configured to copy program schedules from one memory module to another without use of the optional memory module programmer. 5. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 6. Controller shall program in L one minute resolution. 7. Display shall be of LCD type. 8. Controller shall be capable of 99 set points; separate scheduling for each day ofLOAD theL week. LOAD 9. Controller shall N N have 365 day holiday capabilities with 24 single dates and 4 seasons of unlimited duration. 10. Different daily schedules shall be programmable within each season. 11. Controller shall have Daylight Saving or Standard time. 12. Controller shall have automatic Leap Year correction. 13. Controller shall haveDPDT Permanent Schedule Retention. 14. Controller shall have 7 day backup for real time with built in super capacitor. 15. Controller shall be capable of manual override ON or OFF to the next Scheduled event using 1 button for each channel. 16. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 17. Controller shall C NO NC beC capable NO NCof having 2 different pulse durations 1-99 seconds, user settable and assignable to each channel. DZS100BP 18. Controller shall be capable of having astronomic on one (or all) channels with 1-240 minutes, plus or minus offset from Sunrise or Sunset. 19. Controller shall be capable of being configured to copy to multiple memory modules. 20. To order L L specify TORK Model DZS100BP (DZS200BP) (DZS400BP). LOAD LOAD N 120 208-240 277 120V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE 208-240V 277V TIMER SUPPLY MEMORY MODULE: Removable MM can be programmed at any one location and inserted into another DZS series unit. N COPY FEATURE: Unit can be configured to copy program schedule to multiple memory modules. OPTION: Memory Module Programmer with software for computer connection programming. Also allows stand alone battery operation for portable copy feature. TORK 65 277 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com 208-240V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE 277V TIMER SUPPLY N 120 208-240 277 120V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE DIGITAL CONTROLS 120 208-240 120V 208-240V 277V N N TORK 66 L DTS SERIES MAINTAINED AND SIGNAL TIMING MULTIPURPOSE CONTROLS 1, 2 OR 4 CHANNEL 365 / 7 DAY ADVANCE TIME SWITCH DTS400B SPECIFICATIONS Indoor and outdoor lighting Heating and air conditioning Security systems Horns and bells Low voltage lighting Misting and spraying Roof cooling Clock correction systems Process functions CH 2 SPDT NO C TIMER SUPPLY N 120 NC LOAD POWER CONSUMPTION: 6VA Max. UPPER GND NO ENCLOSURE: Noryl® Indoor/Outdoor NEMABOARD 3R with lockable hasp (see page 153 for enclosure dimensions). CH 1 SPDT NO L DTS400B N 120 13A 15A 2A 120VAC 8A 120-277VAC Pilot Duty 120-277VAC Motor Load 120VAC 208-277VAC 1HP 2HP 1HP 2HP 28VDC 30A 30A C NC Resistive 720VA 720VA 12-277VAC 720VA 720VA 120-277VAC 1HP 1HP L N NO NC C NO NC CH 1 SPDT WIRING DIAGRAMS 120-277VAC 20A LOAD N C TIMER SUPPLY DTS200B 10A 10A Tungsten CH 2 SPDT LOAD 30A 20A 120VAC 277VAC CH 4 SPDT NC 20A Ballast LOAD C 24-277VAC 30A N CH 3 SPDT 30A 24-277VAC L N 277V RATING NO NC General NC Purpose NO C L 208-240V DTS400B VOLTAGE VOLTAGE 208-240 277 120V DTS100B, DTS200B RATING NO NC TYPE TIMING ACCURACY: Line Frequency. OPERATING TEMPERATURE: -40° to +149° (-40° to +65°C). ASHRAE 90.1 CONTACT RATINGS N CH 1 SPDT TERMINAL RANGE: AC LINE INPUT #14 - #16AWG for lineSELECT input. PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE #12 - #16AWG load outputs. CALIFORNIA Title 24 LOAD N INPUT VOLTAGE: 120/208-277VAC, LOWER 50/60Hz. BOARD APPLICATIONS L LOAD CH 2 SPDT 208-240 277 120V 208-240V TIMER SUPPLY AC LINE INPUT SELECT PROPER TERMINALS LOWER AND APPLY ONLY ONE VOLTAGE L NO C BOARD N 120 ORDERING INFO FEATURES SCHEDULING: 99 ON/OFF set points allow individual programs for each day of the week at a minimum 1 minute apart. SEASONS: 1 to 4 with different daily schedules which can wrap around into the new year. CATALOG NO. UPC CODE TIMER SUPPLY (VAC) 50/60Hz DTS100B NO. OF CHANNELS DRY CONTACTS (UNPOWERED) DTS100B 82185 120/208-240/277 1 DPDT DTS200B 82186 120/208-240/277 2 SPDT DTS400B 82187 120/208-240/277 4 SPDT LOAD DPDT L LOAD C NC L LOAD N 277V TIMER SUPPLY 120 NO C N 208-240 277 208-240V N NC N 120V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE L LOAD 277V CH 3 SPDT N NO NC C NO NC UPPER BOARD 208-240 277 120V C TIMER SUPPLY N CH 1 SPDT CH 2 SPDT NO NC C 120 NO C DTS400B LOAD N N CH 1 SPDT NO NC CH 2 SPDT NO C TIMER SUPPLY NC L LOAD N 208-240 277 120 NC NO C NC 208-240 277 L 120V 208-240V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE L L LOAD 277V LOAD N N AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE L LOAD 208-240V LOAD N 277V N DPDT N MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. In signal mode, activates pulse. C TIMER SUPPLY DTS100B LEAP YEAR: Automatic Compensation. 120 NO NC C NO NC 208-240 277 CH 1 SPDT 120V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE 208-240V L L LOAD CH 2 SPDT LOAD N N SPECIFICATION WRITER’S GUIDE C NO NC C NO NC DTS SERIES – 1. Furnish and install, where noted, a 4 (2) (1) channel digital time switch.DTS200B 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each L day of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates and 4 seasonsACofLINEunlimited duration. 7. Different dailyL schedules shall be INPUT LOAD LOAD SELECT PROPER TERMINALS programmable within each season. 8. Controller shall have Daylight Saving or Standard time. 9.APPLY Controller have automatic Leap Year Ncorrection. 10. Controller shall AND ONLY ONEshall VOLTAGE N have Permanent Schedule Retention. 11. Controller shall have 7 day backup for real time with built in super capacitor. 12. Controller shall be capable of manual override DPDT ON to activate pulse #1 duration. 13. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure as standard. 14. Controller shall be capable of having two different pulse durations 1-99 seconds, user settable and assignable to each channel. 15. To order specify TORK Model DTS100B (200B) (400B). 277V TIMER SUPPLY N CLOCK FORMAT: AM/PM or Military time. 120 208-240 277 120V 208-240V POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 7 days of real time back up. 277V C TIMER SUPPLY DTS100B N TORK 67 NC L LOAD N 120V DAYLIGHT SAVING: Automatic adjustment (can be omitted). DIGITAL CONTROLS C LOWER BOARD N SIGNAL/PULSE DURATION: 2 different settings per channel: each 1-99 seconds. GND NO L LOAD 277V DTS200B HOLIDAYS: 1 to 24 individual dates. L 208-240V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE CH 4 SPDT 120 NO NC C NO NC 208-240 277 120V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com 208-240V 277V L L LOAD N LOAD N TORK 68 DW SERIES SPECIFICATION FAVORITE! MULTIPURPOSE CONTROLS 365 / 7 DAY ADVANCED 1 OR 2 CHANNEL TIME SWITCHES CONTACT RATINGS SPECIFICATIONS VOLTAGE General Purpose NC 24-277VAC 30A 30A Ballast 120VAC 277VAC 30A 20A 10A 10A Tungsten 120-277VAC 15A 2A Pilot Duty 120-277VAC 720VA 720VA Motor Load 120VAC 208-277VAC 1HP 2HP 1HP 2HP Resistive 28VDC 30A 30A TERMINAL RANGE: #14 - #16AWG for line input. #12 - #16AWG load outputs. OPERATING TEMPERATURE: -40° to +158°(-40° to 70°C). 1 CHANNEL Outdoor lighting Security lighting Parking lot lighting Canopy lighting RATING NO TIMING ACCURACY: Line Frequency. INPUT VOLTAGE: 120/208-240-277VAC, 50/60Hz. APPLICATIONS POWER CONSUMPTION: 5VA Max. ENCLOSURE: Noryl Indoor/Outdoor NEMA 3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All with lockable hasp (see page 153 for enclosure dimensions). ® 2 CHANNEL HVAC equipment Interior lighting Electric motors Refrigerator defrost control: condensers, heaters. WIRING DIAGRAMS DWZ100B DWZ100B SERIES SERIES ORDERING INFO CATALOG NO. UPC CODE TIMER SUPPLY (VAC) 50/60Hz NO. OF CHANNELS DRY CONTACTS (UNPOWERED) SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week at a minimum 1 minute apart. DWZ100B 82189 120/208-240/277VAC 1 SPDT DW200B 82190 120/208-240/277VAC 2 SPDT ASTRONOMIC (DWZ100B only): Adjustable 10°- 60° Northern or Southern latitudes. Can be individually offset +/- 1 to 240 minutes from both sunset and sunrise times. DW200B-0 FEATURES TYPE 82231 120/208-240/277VAC 2 SPDT TIMER SUPPLY TIMER SUPPLY N 120 120V N 208-240 120277 208-240 L 120V 277 SPDT TIMER SUPPLY TIMER SUPPLYC N L N 277V AC LINE INPUT AC LINE INPUT SELECT PROPER SELECTTERMINALS PROPER TERMINALS AND APPLY ONE VOLTAGE AND APPLY ONLY ONEONLY VOLTAGE LOAD N CH 1 CH 2 SPDT SPDT CH 2 SPDT DW200B DW200B SERIES SERIES NO CNC NO NC LOAD 208-240V208-240V 277V C SPDT CH 1 SPDT 120 120V N 208-240 120277 208-240 120V L 208-240V208-240V 277V 277V NO CNC NO C NC NO CNC NO NC 277 L LOAD N L L LOAD LOAD N N LOAD N AC LINE INPUT AC LINE INPUT SELECT PROPER SELECTTERMINALS PROPER TERMINALS AND APPLY AND ONLY APPLY ONEONLY VOLTAGE ONE VOLTAGE HOLIDAYS: 1 to 24 individual dates. DAYLIGHT SAVING: Automatic adjustment (can be omitted). TWO SPEED TWOPUMP SPEEDWIRING PUMP WIRING LEAP YEAR: Automatic Compensation scheduled ON or OFF, automatic operation then resumes. SPECIFICATION WRITER’S GUIDE DWZ100B – 1. Furnish and install, where noted, a 1 channel digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each day of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates. 7. Controller shall have Daylight Saving or Standard time. 8. Controller shall have automatic Leap Year correction. 9. Controller shall have Permanent Schedule Retention. 10. Controller shall have 7 day backup for real time with built in supercapacitor. 11. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button. 12. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure as standard. 13. Controller shall be capable of having astronomic with 1-240 minutes, plus or minus offset from sunrise or sunset. 14. To order specify TORK Model DWZ100B. DW200B – 1. Furnish and install, where noted, a 2 channel digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each day of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates. 7. Controller shall have Daylight Saving or Standard time. 8. Controller shall have automatic Leap Year correction. 9. Controller shall have Permanent Schedule Retention. 10. Controller shall have 7 day backup for real time with built in supercapacitor. 11. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button. 12. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM or Military time. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 7 days of real time backup. DIGITAL CONTROLS TORK 69 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 70 DZM SERIES GREAT FOR LATCHING CONTACTORS MOMENTARY OUTPUT 365 / 7 DAY ADVANCED LIGHTING CONTROL TIME SWITCH APPLICATIONS CALIFORNIA Title 24 Low voltage latching relays Direct wire to mechanically held contactors General Purpose 120-277VAC 20A Pilot Duty 120-277VAC 720VA POWER CONSUMPTION: 4VA Max. ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All with lockable hasp (see page 153 for dimensions). FEATURES SEASONS: 1 to 4 with different daily schedules which can wrap around into the new year. RATING OPERATING TEMPERATURE: -40˚ to 158˚F (-40˚ to +70˚C). ASHRAE 90.1 ASTRONOMIC: Adjustable 10° - 60° Northern or Southern latitudes can be individually offset +/- 1 to 240 minutes from both sunset and sunrise times. VOLTAGE TERMINAL RANGE: #14 - #16AWG for line input. #12 - #16AWG load outputs. energy WIRING DIAGRAMS ORDERING INFO CATALOG NO. UPC CODE TIMER SUPPLY (VAC) 50/60Hz NO. OF CHANNELS DZM200BP 82188 120/208-240/277 2 DZM200BP-0 82232 120/208-240/277 2 USB-MMP 82196 Memory Module Programmer DRY CONTACTS (UNPOWERED) SPDT Momentary SPDT Momentary TIMER SUPPLY AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE N 120 208-240V Includes software 277V CH 1 DAYLIGHT SAVING: Automatic adjustment (can be omitted). C ON CH 2 OFF C ON OFF MECHANICALLY HELD CONTACTORS OR LATCHING RELAYS LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. L L PULSE ON PULSE OFF N CLOCK FORMAT: AM/PM or Military time. POWER OUTAGE BACKUP: Permanent scheduled retention with memory module. Supercapacitor provides 7 days of real time backup. PULSE ON PULSE OFF N SPECIFICATION WRITER’S GUIDE DZM 200BP only – 1. Furnish and install, where noted, a 2 channel digital time switch with portable Memory Module on front panel. 2. Memory Module shall be capable of being programmed at any one location and inserted into DZM200BP (with memory module socket) in any other remote location. 3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication of Memory Modules or individualized programs for multiple locations 4. Unit shall have copy feature: Can be configured to copy program schedules from one memory module to another without use of the optional memory module programmer. 5. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 6. Controller shall program in one minute resolution. 7. Display shall be of LCD type. 8. Controller shall be capable of 99 set points; separate scheduling for each day of the week. 9. Controller shall have 365 day holiday capabilities with 24 single dates and 4 seasons of unlimited duration. 10. Different daily schedules shall be programmable within each season. 11. Controller shall have Daylight Saving or Standard time. 12. Controller shall have automatic Leap Year correction. 13. Controller shall have Permanent Schedule Retention. 14. Controller shall have 7 day backup for real time with built in super capacitor. 15. Controller shall be capable of astronomic function, adjustable from 10 – 60 degrees Northern or Southern latitude. Each zone can additionally be offset 1 - 240 minutes for both sunset and sunrise. 16. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button for each channel. 17. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 18. Controller shall be capable of 2 independent momentary outputs ON and OFF for each channel. 19. To order specify TORK Model DZM200BP. MEMORY MODULE: Removable MM can be programmed at any one location and inserted into another DZM series unit. COPY FEATURE: Unit can be configured to copy program schedule to multiple memory modules. OPTION: Memory Module Programmer with software for computer connection programming. Also allows stand alone battery operation for portable copy feature. TORK 71 208-240 277 120V HOLIDAYS: 1 to 24 individual dates. DIGITAL CONTROLS DZM200BP TYPE TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 120/208-240/277VAC, 50/60Hz. responsible SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week at a minimum 1 minute apart. CONTACT RATINGS SPECIFICATIONS A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 72 ELC SERIES ENERGY AND LIGHTING CONTROL 1 & 2 ZONE LIGHTING CONTROL TIME SWITCH THE DO-IT-ALL ENERGY & LIGHTING CONTROLLER NEW! FEATURES CALIFORNIA Title 24 CATALOG NO. UPC CODE TIMER SUPPLY (VAC) 50/60Hz NO. OF CHANNELS OUTPUT CONTACTS ELC71PC/120 82517 120 1 DPDT ELC71PC/208-240 82518 208-240 1 DPDT ELC71PC/277 82519 277 1 DPDT ELC72PC/120 82520 120 2 SPDT ELC72PC/208-240 82521 208-240 2 SPDT ELC72PC/277 82522 277 2 SPDT EPC-LC 82233 LCS115M 82082 Accessory Photo Sensor Accessory Momentary Switch SENSOR EVENT: 32 sensor driven events allow individual programs for each day of the week. BLOCK HOLIDAY: 10 holiday blocks can be set for individual days or for duration of any number of days and may use one of 3 holiday schedules. MOMENTARY CONTACT: May be configured for momentary ON/OFF operation to control latching contactors. The ELC71/72 operates as a single-channel unit. DIGITAL CONTROLS TORK 73 VOLTAGE General Purpose POWER CONSUMPTION: 6VA Maximum. ORDERING INFO HOLIDAYS: 26 holidays may be set using 10 individual dates, 10 month type (last Monday in May), or 6 specific holidays with one of 3 independent holiday schedules. UNIVERSAL INPUT: 2 inputs may be assigned to any channel. SWITCHED INPUT: Accepts input from optional momentary or maintained switch. PHOTOSENSOR INPUT: Accepts input from optional sensor. EPC-LC (indoor/outdoor) has a range from 0 to 200 foot-candles. USER DEFINED INPUT: Accepts user supplied 4 – 20 milliamp sensor. TYPE OPERATING TEMPERATURE: -20°F to +140°F (-29°C to + 60°C). ASHRAE 90.1 SCHEDULING: 128 time based events allow individual programs for each day of the week at a minimum 1 minute apart. Event types include ON, OFF, Duration, or Duty Cycle. ASTRONOMIC: Adjustable 10° - 70° Northern or Southern latitudes. Settings can be offset from both sunset and sunrise times. TIMING ACCURACY: Line frequency. TERMINAL RANGE: #10 - #16AWG for line/load. #14 - #22AWG universal input. energy HVAC equipment Indoor/Outdoor lighting Meets indoor/outdoor lighting energy code requirements CONTACT RATINGS INPUT VOLTAGE: 120, 208-240, 277 50/60Hz (model specific). responsible APPLICATIONS SPECIFICATIONS PULSE/TIME DURATION: 4 different ON settings from 1 second to 23 hours, 59 minutes, 59 seconds. DUTY CYCLE: 4 different ON and OFF patterns from 1 second to 23 hours, 59 minutes, 59 seconds. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. REMOTE OVERRIDE: Universal input may be programmed for timed override from a momentary or maintained dry contact switch. A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com RATING NO NC 120/277VAC 20 A 10 A Ballast 120VAC 208-277VAC 20A 10A 10A Tungsten 120-277VAC 5A Pilot Duty 120-240VAC 470VA 275VA Motor 120VAC 208-277VAC 1HP 2HP 1⁄4HP 1⁄2HP ENCLOSURE: Noryl® clear cover Indoor/ Outdoor NEMA 3R with lockable hasp (see page 153 for enclosure dimensions). WIRING DIAGRAMS ELC72 ELC71 SPST MANUAL OVERRIDE: Keyboard button control until the next regularly scheduled ON or OFF, automatic operation then resumes. STAGGERED START: Optional stagger up time between channels, after a power outage; selectable from 5 seconds, 15 seconds, 30 seconds, 1 minute, 5 minutes, 10 minutes, and 15 minutes. CLOCK FORMAT: AM/PM or 24 hour format POWER OUTAGE BACKUP: Capacitor provides minimum of 1 week of real time backup for program and time of day. SPECIFICATION WRITER’S GUIDE Installer shall furnish and install Tork ELC71 single-channel (or ELC72, two-channel) electronic time control. The control shall have 24 hour, 7 day, 365 day, or astronomic capability with 128 events available. It shall also have 4 user-definable durations and duty cycle lengths plus automatic daylight savings time and leap year adjustments. Control shall have remote override capabilities (timed, toggle or enable type.) Control shall have keyboard override until overridden again or until next event is reached. It shall be capable of switching loads based on user-definable temperature and light levels with 32 events available. Control shall have momentary (latching relay) capability and shall have astronomic features plus 30 definable holidays and 6 pre-programmed holidays. Controller shall have 7 day backup for real time with built in supercapacitor. The digital time display shall be 3⁄4” in height. Clock format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. Wiring terminals shall have the capability to accommodate #16 to #10 AWG wire. Control shall be housed in NEMA 3R enclosure with clear-view cover and shall be lockable to guard against vandalism or tampering. TORK 74 ELC SERIES ENERGY AND LIGHTING CONTROL 4, 8 & 12 ZONE LIGHTING CONTROL TIME SWITCH THE DO-IT-ALL ENERGY & LIGHTING CONTROLLER NEW! energy CALIFORNIA Title 24 ASHRAE 90.1 HVAC equipment Indoor/Outdoor lighting Meets indoor/outdoor lighting energy code requirements FEATURES UPC CODE TIMER SUPPLY (VAC) 50/60Hz NO. OF CHANNELS OUTPUT CONTACTS ELC74* 82523 24/120/208-240/277 4 SPDT ELC78 82524 24/120/208-240/277 8 SPDT ELC712 82525 24/120/208-240/277 12 SPDT EPC-LC 82233 Accessory Photo Sensor LCS115M 82082 Accessory Momentary Switch TORK 75 INPUT VOLTAGE: 24/120/208-240/277VAC, 50/60Hz. General Purpose RATING NO NC 120 - 277VAC 20A 10A Ballast 120 VAC 208-277 VAC 20A 10A 10A 3A Tungsten 120-277VAC 5A Pilot Duty 120-240VAC 470VA 275VA Motor 120VAC 208-277VAC 1HP 2HP 1⁄4HP 1⁄2HP WIRING DIAGRAMS SPST *Also CSA certified. BLOCK HOLIDAY: 10 holiday blocks can be set for individual days or for duration of any number of days and may use one of 3 holiday schedules. DIGITAL CONTROLS VOLTAGE ENCLOSURE: Metal Indoor NEMA 1 with lockable hasp (see page 153 for dimensions). CATALOG NO. SENSOR EVENT: 32 sensor driven events allow individual programs for each day of the week. MOMENTARY CONTACT: May be configured for momentary ON/OFF operation to control latching contactors. The ELC74 operates as a two channel unit. The ELC78 operates as a four channel unit. The ELC712 operates as a six channel unit. TYPE OPERATING TEMPERATURE: -20°F to +140°F (-29°C to + 60°C). ORDERING INFO HOLIDAYS: 26 holidays may be set using 10 individual dates, 10 month type (last Monday in May), or 6 specific holidays with one of 3 independent holiday schedules. UNIVERSAL INPUT: 8 inputs may be assigned to any channel. ELC74 includes 4. SWITCHED INPUT: Accepts input from optional momentary or maintained switch. PHOTOSENSOR INPUT: Accepts input from optional sensor. EPC-LC (indoor/outdoor) has a range from 0 - 200 foot-candels. USER DEFINED INPUT: Accepts user supplied 4 – 20 milliamp sensor. TIMING ACCURACY: Line frequency. POWER CONSUMPTION: 10VA Maximum. SCHEDULING: 128 time based events allow individual programs for each day of the week at a minimum 1 minute apart. Event types include ON, OFF, Duration, or Duty Cycle. ASTRONOMIC: Adjustable 10° - 70° Northern or Southern latitudes. Settings can be offset from both sunset and sunrise times. CONTACT RATINGS TERMINAL RANGE: #10 - #16AWG for line input. #10 - #16AWG for load output. #14 - #22AWG universal input. responsible APPLICATIONS SPECIFICATIONS PULSE/TIME DURATION: 4 different ON settings from 1 second to 23 hours, 59 minutes, 59 seconds. DUTY CYCLE: 4 different ON and OFF patterns from 1 second to 23 hours, 59 minutes, 59 seconds. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. REMOTE OVERRIDE: Universal input may be programmed for timed override from a momentary or maintained dry contact switch. MANUAL OVERRIDE: Keyboard button control until the next regularly scheduled ON or OFF, automatic operation then resumes. A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com STAGGERED START: Optional stagger up time between channels, after a power outage; selectable from 5 seconds, 15 seconds, 30 seconds, 1 minute, 5 minutes, 10 minutes, and 15 minutes. CLOCK FORMAT: AM/PM or 24 hour format. POWER OUTAGE BACKUP: The program and time of day are maintained for a minimum of 2 days by means of a capacitor. After two days, a lithium battery takes over and provides a minimum accumulated time of 1 year. The lithium battery should provide over 10 years of protection. COMPUTER INTERFACE: Unit may be programmed with a PC. SPECIFICATION WRITER’S GUIDE Installer shall furnish and install Tork ELC74 four channel (ELC78 eight channel or ELC712 twelve channel) electronic time control. The control shall have 24 hour, 7 day, 365 day or astronomic capability with 128 events available. It shall also have 4 (8) user-definable durations and duty cycle lengths plus automatic daylight saving time and leap year adjustments. Control shall have remote override capabilities (timed, toggle or enable type). Control shall have keyboard override until overridden again or until next event is reached. It shall be capable of switching loads based on user-definable temperature and light levels with 32 events available. Control shall have momentary (latching relay) capability and shall have astronomic features plus 30 definable holidays and 6 pre-programmed holidays. Control shall provide 2 days of power outage carry-over without a battery. Control shall provide 10 years of power outage protection with a battery. The digital time display shall be 3⁄4” in height. Clock format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. Control shall be capable of interfacing (sending and receiving data) with a personal computer. Control shall be housed in a NEMA 1, lockable steel enclosure, to guard against vandalism or tampering. TORK 76 CONTACT RATINGS Resistive TERMINAL RANGE: Relay #12AWG; input power terminals #14 - #22AWG; TOD/sensor terminals accept #18 - #22AWG. responsible energy APPLICATIONS ASHRAE 90.1 Pilot Duty POWER CONSUMPTION: 5VA Maximum. NO NC 120/240VAC 277VAC 120VAC 240/277VAC 20A 12A 20A 6A 10A 120/240/277VAC 5A 120/240VAC 277VAC 10A 3A 3A LIGHT LEVEL STAGE 1 470VA 690VA 4 5 6 STAGE 2 3 8 2 9 1 275VA 4 7 POWER 1 10 OTHER MOUNTINGS: LC200M mechanism only. For 120 VAC Operation NEUT 120V240V 277V LINE INPUT N H WIRING DIAGRAMS STAGE 1 C NO NC 5 6 7 3 8 2 SET ENCLOSURE: LC200 includes metal Indoor NEMA 1 with lockable hasp (see page 153 for dimensions). EPC1 sensor supplied with unit. Use to control two different outdoor lighting circuits utilizing one photocell. Sign lighting can turn ON at one ambient light level while parking lot lighting turns ON at a different light level. 9 10 RUN STAGE 2 C NO NC OUTPUT 1 OUTPUT 2 WHITE BLACK LOAD 1 TOD1 C TOD2 LOAD 2 CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 50/60Hz NO. OF ZONES OUTPUT CONTACTS PHOTOSENSOR INPUT: EPC1 included. LC200 82111 120/240/277VAC 2 SPDT DUAL OUTPUTS: with independent turn-ON adjustment for Stage1 and Stage 2. LC200M 120/240/277VAC 2 5 6 STAGE 2 4 7 5 6 8 3 8 9 2 9 1 10 SET LINE INPUT 10 RUN H H C NO NC C NO NC OUTPUT 1 OUTPUT 2 RED BLACK LOAD 1 STAGE 1 STAGE 2 LOAD 2 SPDT For 277 VAC Operation NEUT 120V240V 277V LINE INPUT N H C NO NC C OUTPUT 1 OUTPUT 2 WHITE BLACK NEUT 120V240V 277V LINE INPUT H H LINE INPUT N H C NO NC C NO NC OUTPUT 1 OUTPUT 2 WHITE ORANGE LOAD 1 LOAD 2 LOAD 2 For 240 VAC Operation NEUT 120V240V 277V NO NC LOAD 1 SWITCHED INPUT: Can be used with a time switch for photocell ON of two different lighting circuits at different ambient light levels, then time-of-day OFF. NEUT 120V240V 277V 7 3 2 1 For 120 VAC Operation LIGHT LEVEL ACTIVATION: Turn ON is user settable from 2 to 100 footcandle; Independent light level adjustment for each zone. Turn OFF is a maximum of 2 times turn ON level. Built-in delay ON of 30 seconds to avoid reaction to lightning or headlights. STAGE 1 4 POWER 82113 For 240 VAC Operation LIGHT LEVEL EPC EPC1 ORDERING INFO FEATURES Tungsten OPERATING TEMPERATURE: -40°F to +140°F (-40°C to + 60°C). TOD1 C TOD2 24 hour convenience stores Open wall parking structures Large canopies Building perimeters Atriums Ballast RATING VOLTAGE EPC TYPE INPUT VOLTAGE: 120/240/277VAC, 50/60Hz. TOD1 C TOD2 SPECIFICATIONS TOD1 C TOD2 STAGE LIGHTING TURN ON LEVEL LIGHT LEVEL / TIME OF DAY OPTION 2 ZONES LIGHTING CONTROL TIME SWITCH EPC1 LC200 SERIES C NO NC C NO NC OUTPUT 1 OUTPUT 2 RED BLACK LOAD 1 SPECIFICATION WRITER’S GUIDE LOAD 2 Furnish and install an electronic light sensor and control with dual outputs for two lighting zones. Each output shall be capable of a different user settable turn ON light level set For points277 fromVAC 2 to 100 footcandles. Turn ON to turn OFF ratio shall be 1:2. Controller shall also offer two digital inputs, which can accept a contact Operation closure from an independent time switch or EMS system, thereby allowing for independent time of day control. LINE INPUT OUTPUT 1 OUTPUT 2 NEUT 120V240V 277V N H C NO NC C NO NC WHITE ORANGE LOAD 1 LOAD 2 DIGITAL CONTROLS TORK 77 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 78 DGU & DGLC SERIES CODE SOLUTION FOR SMALL PROJECTS NEW! LIGHTING CONTROL WITH PHOTO OR OVERRIDE INPUT, 7 DAY 7 DAY LIGHTING CONTROL TIME SWITCH TERMINAL RANGE: #12 - #18AWG for line/load. #18 - #26AWG sensor/switch input. responsible energy APPLICATIONS EXTERIOR LIGHTING Signage and store windows Security Parking lots FEATURES ASHRAE 90.1 Model EPC-A supplied with DGLC-A unit. CATALOG NO. With optional Timed Override 82211 120-277VAC 1 DPDT DGUM100A 82212 120-277VAC 1 DGUM100A-Y 82224 120-277VAC 1 SPDT Momentary SPDT Momentary DGLC100A-NC 82223 120-277VAC 1 DPDT DGLC200A-NC 82213 120-277VAC 2 SPDT EPC-A 82112 Accessory Photo Sensor SSA200R-24 14015 24VAC/24VDC TRP-U 82030 120/277VAC PHOTOSENSOR INPUT: Unique push button set-up assures accurate operation with automatic calibration that adjusts for wire size and distance. EPC-A photo sensor is included with the DGLC-A and may be ordered as an option for use with model DGU100A & DGUM100A. MOMENTARY CONTACT - DGUM100A: 2 second contact closure ON & OFF to control mechanically held contactors or latching relays. DIGITAL CONTROLS TORK 79 OUTPUT CONTACTS VOLTAGE Resistive ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R . Suffix -NC Noryl® Indoor/Outdoor NEMA 3R with clear Lexan® cover. Suffix -Y metal Indoor enclosure NEMA 1. All with lockable hasp (see page 153 for dimensions). RATING NO NC 24-277VAC 20A 10A Ballast 120VAC 277VAC 20A 10A Tungsten 120VAC 15A Motor POWER CONSUMPTION: 6VA Maximum. INPUT SUPPLY NO. OF (VAC) 50/60 Hz CHANNELS DGU100A-Y MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. REMOTE OVERRIDE ON: Each channel has independent input for a maintained dry-contact closure. May use TORK model SSA200R-24 and TRP-U for timed override. May use with occupancy sensor as override. UPC CODE TYPE Pilot Duty OPERATING TEMPERATURE: -31°F to +131°F (-35°C to + 55°C). ORDERING INFO SCHEDULING: 56 ON & OFF set points provide individual programs for each day of the week. Minimum setting is 1 minute. LIGHT LEVEL ACTIVATION: Turn ON is user settable from 1 to 100 footcandle; Turn OFF is a maximum of 2 times turn ON level. Each channel has an independent setting. Includes a user settable delay before ON or OFF between 1 – 90 seconds. TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 120-277VAC, 50/60Hz (auto detection). CALIFORNIA Title 24 INTERIOR LIGHTING Open office zoning Hallways Meeting and sales areas Stock rooms and warehouses CONTACT RATINGS SPECIFICATIONS Resistive 120VAC 240VAC 120VAC 240VAC 28VDC DGU100A 1HP 2HP 290VA 360VA 1⁄4HP 1⁄2HP 20A 10A 720VA DGUM100A DGU100A WIRING DIAGRAMS DGU100A DGLC100A DGUM100A SPDT Transformer Power Pack SPST DGUM100A DGLC100A DGLC200A BLOCK HOLIDAY: 9 holiday blocks can be set for individual days or for duration of any number of days. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. CLOCK FORMAT: AM/PM or 24 Hour format. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 7 days of real time backup. A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com DGLC100A DGLC200A SPECIFICATION WRITER’S GUIDE DGU and DGLC SERIES - 1. Furnish and install, where noted, a 1 (2) channel 7 day programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast load at 277VAC. 4. Controller shall be capable of 56 set points; separate scheduling for each day of the week with one minute resolution. 5. Controller shall have photo sensor input user adjustable per circuit between 1 and 100 footcandle turn ON level. 6. Each channel shall have and switched input to override circuit ON. 7. Controller shall have 365 day holiday capabilities with 9 block holidays for individual or duration of any number of days. 8. Controller shall be able to select USA Standard Daylight Saving, Standard time, or programmable dates. 9. Controller shall have automatic Leap Year correction. 10. Controller shall have Permanent Schedule Retention. 11. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 12. Controller shall be capable of Manual Override ON and OFF to the next scheduled event using 1 button for each channel. 13. Unit shall have NEMA type 3R indoor/outdoor enclosure standard. 14. To order specify TORK Model DGU100A. (Alt 14. To order 1 channel momentary contact closure for latching contactor control specify DGUM100A). (Alt 14. To order controller with EPC-A photo sensor included in package specify TORK Model DGLC100A-NC (DGLC200A) with clear cover. TORK 80 DLC400BP FLEXIBLE INDOOR/ OUTDOOR LIGHTING CONTROLLER 4 ZONE LIGHTING CONTROL TIME SWITCH responsible energy APPLICATIONS INTERIOR LIGHTING Open office zoning Hallways Meeting and sales areas Stock rooms and warehouses EXTERIOR LIGHTING Signage and store windows Security Parking lots FEATURES CONFIGURABLE ZONES: Simple three position slide switch sets logic for each zone: Time ON/Time OFF, Photo ON/Photo OFF, or Photo ON/ Time OFF. SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week. Minimum 1 minute apart. ASTRONOMIC: 1. Adjustable 10° - 60° Northern or Southern latitudes. 2. Can be individually offset +/-1-240 minutes from both sunset and sunrise times. PHOTOSENSOR INPUT: EPC2 photo sensor included. LIGHT LEVEL ACTIVATION: Turn ON and OFF level is user settable from 1 to 100 footcandle. Each channel has an independent setting. REMOTE OVERRIDE: Maintained dry contact closure or use TORK Model SSA200R-24 for timed override with flash warning before OFF. May use with occupancy sensor as override. DIGITAL CONTROLS TORK 81 CALIFORNIA Title 24 SPECIFICATIONS TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 120/208 - 240/277VAC, 50/60Hz. CONTACT RATINGS TYPE VOLTAGE General Purpose 24-277VAC, 30VDC RATING NO NC 30A 30A 10A TERMINAL RANGE: #10 - #14AWG. Ballast 120-277VAC 20A OPERATING TEMPERATURE: -40°F to +158°F (-40°C to + 55°C). Tungsten 120VAC 10A Pilot Duty 120-277VAC 720VA 720VA POWER CONSUMPTION: 30VA Maximum. ASHRAE 90.1 ENCLOSURE: Metal Indoor/Outdoor NEMA 3 with lockable hasp (see page 153 for dimensions). Model EPC2 supplied with unit. Memory Module Programmer optional WIRING DIAGRAMS With optional Timed Override ORDERING INFO CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 50/60 Hz NO. OF CHANNELS OUTPUT CONTACTS DLC400BP 82191 120/208-240/277 4 SPDT USB-MMP 82196 Memory Module Programmer SSA200R-24 14015 24VAC/24VDC Includes Software SPDT MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. SEASONS: 1 to 4 with different daily schedules which can wrap around into the new year. HOLIDAYS: 1 to 24 individual dates. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. POWER OUTAGE BACKUP: Permanent schedule retention with memory module. Battery provides real time backup for 6 months cumulative. MEMORY MODULE: Removable MM can be programmed at any one location and inserted into another DZS series unit. OPTION: Memory Module Programmer with software for computer connection programming. Also allows stand alone battery operation for portable copy feature. A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com SPECIFICATION WRITER’S GUIDE DLC400BP – 1. Furnish and install, where noted, a 4 zone lighting controller with photosensor input (TORK model EPC2 photosensor to be supplied with controller). 2. Memory Module shall be capable of being programmed at any one location and inserted into DLC400BP (with memory module socket) in any other remote location. 3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication of Memory Modules or individualized programs for multiple locations 4. Each zone shall be capable of independent, user settable turn ON and turn OFF light level set points ranging from 1 to 100 footcandles. 5. Three position slide switches shall be provided for each of the 4 zones allowing for user settings based on a) time of day or b) combination time of day and light level or c) light level. 6. Controller shall provide 30 Amp General Purpose isolated contacts (unpowered) for each zone as well as a 500 ma, 24VDC output. 7. Controller shall have 1 digital input per channel for: a) remote contact closure which can be used to turn corresponding outputs ON/OFF outside of the normal control time or b) remote timed override which can be accomplished for the corresponding outputs with the use of TORK model SSA200R-24. 8. Enclosure shall provide separate wiring compartments for power connections and auxiliary connections. 9. Controller shall be capable of local override ON or OFF to the next scheduled event using the keypad for each zone. 10. Each zone shall be capable of astronomic function, adjustable from 10 – 60 degrees Northern or Southern latitude. Each zone can additionally be offset +/- 1–299 minutes for both sunset and sunrise. 11. Controller shall provide automatic daylight saving time (which can be omitted). Leap year adjustment shall be compensated for automatically. 12. Controller shall have 365 day holiday capability with 24 single dates and 4 seasons of unlimited duration. 13. Controller shall be capable of 99 set points with separate scheduling for each day of the week. 14. Controller shall have back-up capability: a) Schedule shall be retained for 40 years without power, b) real time shall be retained for 6 months using a field replaceable 9V lithium battery. 15. Unit shall have a NEMA type 3, metal indoor/outdoor enclosure. TORK 82 LD SERIES ADD A WARNING BLINK TO ANY CONTROL EXTENDED LIGHTING CONTROL LIGHTING DELAY TIME SWITCH INPUT VOLTAGE: 120/208/240/277VAC, 50/60Hz. TERMINAL RANGE: #10 - #16AWG. OPERATING TEMPERATURE: -22° to 150°F (-30° to +65°C). ASHRAE 90.1 APPLICATIONS CONTACT RATINGS SPECIFICATIONS POWER CONSUMPTION: 5VA Maximum. ® ® ENCLOSURE: Metal Indoor NEMA 1 with lockable hasp (see page 153 for dimensions). ® ® Open offices Gymnasiums Warehouses Outdoor recreation courts User-activated lights with time limits Match with photocontrol and timer to limit hours of use RATING TYPE VOLTAGE General Purpose Ballast 24/240VAC 277VAC 120VAC 208-277VAC Tungsten 120-277VAC 5A 3A Pilot Duty 120-240VAC 27VAC 470VA 690VA 275VA Resistive 28VDC 20A 10A NO NC 20A 20A 20A 10A 10A 3A 10A 3A WIRING DIAGRAMS LDSH WIRING LDS WIRING TORK TIME SWITCH TORK TIME SWITCH OUTPUT TERMINALS OUTPUT TERMINALS OFF NO C OFF NC MOMENTARY PUSH-BUTTON SWITCH C ON OFF DO NOT APPLY VOLTAGE N TIME SWITCH INPUT 120 208 240 H REMOTE INPUT 277 VAC H C ON OFF DO NOT APPLY INPUT POWER VOLTAGE NO N N C 277 VAC INPUT POWER AUX. OUTPUT TERMINALS NC 208 240 120 TIME SWITCH INPUT MAIN LOAD OUTPUT TERMINALS NC 120 VAC ON ON N NC N N H C MOMENTARY PUSH-BUTTON SWITCH H REMOTE INPUT NO MAIN LOAD OUTPUT TERMINALS NO C NC NO C H H H AUX LOAD ORDERING INFO FEATURES MAINTAINED INPUT WITH LOAD WARNING BLINK: LDS Series controls output load contacts based on power applied to the time switch input contact. At removal of power from the time switch input, LDS Series provides 1 second blink then keeps load contacts closed for an extra 1 or 5 minutes (user selectable) before turn off. MAINTAINED INPUT WITH AUXILARY WARNING: LDSH Series controls output load contacts based on power applied to the time switch input contact. At removal of power from the time switch input, LDSH Series closes a second set of contacts for a user supplied audible or visual warning device. The warning circuit closes for a selected time of 4 seconds (best for audible device or continuous, then keeps load contacts closed for an extra 1 or 5 minutes (user selectable) before turn OFF. CATALOG NO. LDS-A LDS LDSH-A LDSH UPC CODE 81026 81025 81031 81028 INPUT SUPPLY (VAC) 50/60 Hz 120/208-240/277 120/208-240/277 120/208-240/277 120/208-240/277 MOMENTARY INPUT: Provides timed override when time switch input contact is unpowered (timer OFF). When activated during the warning period, load contacts are kept closed and timing starts. Both series can accept momentary input contact closure for ON to start the timing and OFF to end the timing. TIMED OVERRIDE SETTINGS: User may select override times of 1⁄2, 1, 11⁄2, 2, 6, 9, or 12 hours. Warning before OFF is always active after override time. LOAD OUTPUT CONTACTS ENCLOSURE TYPE SPDT Metal Indoor NEMA 1 SPDT SPDT SPDT Mechanism Metal Indoor NEMA 1 Mechanism N TORK TIME SWITCH TORK TIME SWITCH OUTPUT TERMINALS OUTPUT TERMINALS OFF NO C OFF NC MOMENTARY PUSH-BUTTON SWITCH VOLTAGE N TIME SWITCH INPUT N 120 208 240 H 120 VAC REMOTE INPUT 277 VAC H C ON OFF DO NOT APPLY INPUT POWER VOLTAGE NO N N C NO 277 VAC INPUT POWER AUX. OUTPUT TERMINALS NC 208 240 120 TIME SWITCH INPUT MAIN LOAD OUTPUT TERMINALS NC NC ON ON H C N N C ON OFF DO NOT APPLY NO MOMENTARY PUSH-BUTTON SWITCH H REMOTE INPUT N LOAD N MAIN LOAD OUTPUT TERMINALS C NC NO C H H H ON OFF COMMON AUX LOAD MECHANICALLY HELD CONTACTOR WITH COIL CLEARING CONTACTS ON N MECHANICALLY HELD CONTACTOR WITH COIL CLEARING CONTACTS OFF COMMON PHOTOCONTROL N N TORK TIME SWITCH OUTPUT TERMINALS APPLICATION EXAMPLE Lighting for a high school’s tennis courts turns on during normal class hours when natural light diminishes using a 7 day time switch and photocell. After 3pm, staff members sometimes use the courts (the time switch is then off). A momentary pushbutton activates the LDSH for timed override of HID lighting. Five minutes before the lights go out, an auxiliary contact flashes an incandescent warning beacon (HID lighting can not be made to blink). Additional timed override can be arranged for via the momentary pushbutton. APPLICATION WIRING NO C NC FLASHING LIGHT H 120V N C ON H OFF N N 120 208/240277 REMOTE INPUT TIME SWITCH INPUT MOMENTARY PUSHBUTTON SWITCH AUXILLARY OUTPUT NO C LDSH NC INPUT POWER N MAIN LOAD OUTPUT NO C NC 120V OFF N ON H 120V N OFF SWITCHED CIRCUIT TO TENNIS COURT LIGHTS ON N MECHANICALLY-HELD 4 POLE LIGHTING CONTACTOR SWITCHED CIRCUIT TO TENNIS COURT LIGHTS 480V CIRCUITS FROM PANEL DIGITAL CONTROLS TORK 83 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 84 DGS SERIES SIGNALING AND DUTY CYCLE 24 HOUR OR 7 DAY TIME SWITCH 31 DAY CYCLE TIME: AN INDUSTRY FIRST! NEW! SPECIFICATIONS TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 120 - 277 VAC, 50/60 Hz (auto detection). TERMINAL RANGE: #12 - #18AWG. OPERATING TEMPERATURE: -31°F to +131°F (-35°C to + 55°C). APPLICATIONS POWER CONSUMPTION: 6VA Maximum. Signaling Duty cycle ENCLOSURE: Noryl Indoor/Outdoor NEMA 3R with lockable hasp (see page 153 for enclosure dimensions). ® CONTACT RATINGS TYPE VOLTAGE Resistive RATING NO NC 24-277VAC 20A 10A Ballast 120VAC 277VAC 20A 10A Tungsten 120 VAC 15 A Motor 120 VAC 240VAC 120VAC 240VAC Resistive 28VDC Pilot Duty 720VA 1HP 2HP 20A 290VA 360VA 1⁄4HP 1⁄2HP DGS100A FOR 120V/277VAC 10A WIRING DIAGRAMS DGS100A FOR 208-240VAC DGS100A FOR 120V/277VAC DG180A FOR 120V/277VAC ORDERING INFO FEATURES DG180A & DG280A: 56 ON & OFF set points provide individual daily programs. Minimum setting is 1 minute. DGS100A: 56 ON & OFF set points provide individual programs for each day of the week. Minimum setting is 1 minute. DUTY CYCLE: Two different ON/OFF patterns or signal durations may be programmed. The durations can be up to 23 hours, 59 minutes and 59 seconds in length. SKIP FUNCTION (24 HOUR UNITS ONLY): Each channel can be set for ACTIVE/SKIP operations that alternate from 1 - 31 days. This becomes an effective way to cycle loads on varying days within the month. Using the two-circuit DG280A, two loads can be set to operate on alternate days in a simple manner. CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 50/60 Hz NO. OF CHANNELS OUTPUT CONTACTS 24 HOUR MODELS DG180A 82206 120-277VAC 1 DPDT DG280A 82207 120-277VAC 2 SPDT DG280A-24 82220 24VAC 2 SPDT 120-277VAC 1 DPDT DGS100A-12 82218 12VDC 1 DPDT DGS100A-24 82219 24VAC 1 DPDT DGS100A FOR 208-240VAC DG180A FOR 208-240VAC DG280A 7 DAY MODELS DGS100A 82205 DAYLIGHT SAVING: Automatic adjustment (can be omitted). DG280A LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM or 24 hour. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 7 days of real time backup. DIGITAL CONTROLS TORK 85 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com SPECIFICATION WRITER’S GUIDE DGS100A SERIES –1. Furnish and install, where noted, a 1 channel 7 day programmable digital time switch. (Alt 1 DG180 Series 1. Furnish and install, where noted, a 1 (2) channel 24 hour programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast load at 277VAC. 4. Controller shall be capable of 56 set points; separate scheduling for each day of the week with one minute resolution. 5. unit shall be capable of two duty cycle or signal durations from 1 second to 23 hours, 59 minutes and 59 seconds. 6. Controller shall be able to select USA Standard Daylight Saving, Standard time or programmable dates. 7. Controller shall have automatic Leap Year correction. 8. Controller shall have Permanent Schedule Retention. 9. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 10. Controller shall be capable of Manual Override ON and OFF to the next scheduled event using 1 button for each channel. 11. Unit shall have NEMA type 3R indoor/outdoor enclosure as standard. 12. To order specify TORK Model DGS100A (Alt 12. Controller shall have a 31 day cycle to alternate days that programs are active or to be omitted. 13. To order specify TORK Model DG180A [DG280A]). TORK 86 EJWT & E500T SERIES NEW! PERFECT FOR PROCESS CONTROL DELAY, INTERVAL & PERCENTAGE TIME CYCLE TIME SWITCHES SPECIFICATIONS CONTACT RATINGS TIMING ACCURACY: 1% of timing range. TYPE VOLTAGE General Purpose Resistive INPUT VOLTAGE: 120/240VAC, 60Hz. TERMINAL RANGE: #12 - #18AWG. OPERATING TEMPERATURE: 32°F to +122°F (0°C to + 50°C). APPLICATIONS POWER CONSUMPTION: 16VA Maximum. EJWT RATING NO NC 120-240VAC 20A 10A 120-240VAC 20A 10A Motor 120VAC 208-240VAC 1HP 2HP 1⁄4HP Pilot Duty 120/240VAC 470VA 275VA 1⁄2HP ENCLOSURE: Indoor NEMA 4X is standard (see page 153 for enclosure dimensions). Poultry and livestock Agriculture or greenhouse Oil well pumping Ventilation Process control E502T E501T EJWT ORDERING INFO FEATURES EJWT – PERCENTAGE TIMER • 960 time combinations with two dials. • Cycle Time Dial sets 32 repeating cycles from 15 seconds to 24 hours. • Percentage ON Dial has 32 steps from 0% to 100%. • Repeats cycle as long as power is applied. CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 60 Hz OUTPUT CONTACT EJWT 82513 120-240VAC SPDT E500T 82514 120-240VAC SPDT E501T 82515 120-240VAC SPDT E502T 82516 120-240VAC SPDT E500T – ON DELAY TIMER • Dial sets 32 time delay durations from 5 seconds to 3 hours. • External switch activated starts delay to ON. • Runs until external switch turns OFF. WIRING DIAGRAMS EJWT E500T / E501T / E502T E501T – AUTO OFF INTERVAL TIMER • Dial sets 32 time durations from 10 seconds to 12 hours. • Start/Stop button or External switch starts interval ON. • Automatically turns OFF at end of preset time. • START/STOP or External switch turns OFF. E502T – OFF DELAY TIME • Dial sets 32 time durations from 5 seconds to 3 hours. • External switch starts interval ON. • Automatically turns OFF at end of preset time. • External switch turns OFF. DIGITAL CONTROLS TORK 87 E500T / E501T / E502T A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 88 DIN SERIES 1 OR 2 CHANNEL 7 DAY TIME SWITCH ASHRAE 90.1 CONTACT RATINGS SPECIFICATIONS PANEL BUILDERS CHOICE CALIFORNIA Title 24 NEW! OPERATING TEMPERATURE: DIN100B: 14°- 131°F (-10°- +55°C). DIN200B: 14°- 113°F (-10°- +45°C). Panel builders Indoor/Outdoor lighting Security systems HVAC equipment CALIFORNIA Title 24 DIN100B VOLTAGE Resistive POWER CONSUMPTION: 4VA Maximum. ASHRAE 90.1 RATING NO NC 120VAC 16A 16A General Purpose 120VAC 8A 8A Motor (DIN100 only) 120VAC 1⁄2HP TERMINAL RANGE: #12 - #18AWG. APPLICATIONS TYPE INPUT VOLTAGE: 120VAC, 50/60Hz. MOUNTING: DIN rail #50022 (35mm) or flat surface using supplied adapter. DIN200B WIRING DIAGRAMS DIN200B DIN200B DIN100B DIN100B ORDERING INFO UPC CODE DRY CONTACTS CLOCK INPUT 50/60 Hz NO. OF CHANNELS NUMBER OF ON/OFF DIN100B 82193 SPDT 120VAC 1 8 2 4 Channel A 3 Channel B DIN200B 82192 SPDT 120VAC 35.80 Channel B (C2) Output 55.00 52.5 NC 14 8 7 6 1 2 3 DIN100B 35.80 46.00 60.00 5 6 1 2 NC NO 2 3 4 5 Input D Channel B (C2) NO 3 1 Channel A (C1) 14 8 7 6 1 2 3 85 85.00 45.00 7 6 60 Channel B (C2) 8 7 35.2 Channel A (C1) Output 52.5 NC 8 Channel A (C1) Channel B (C2) Output 55.00 4 NC NO DIN200B CLOCK FORMAT: AM/PM. Channel B (C2) NO 85 MANUAL OVERRIDE: Until the next regular scheduled ON or OFF, automatic operation then resumes. POWER OUTAGE BACKUP: Battery retains time and schedule. 60 Channel B (C2) 85.00 SCHEDULING: 8 ON and OFF pairs of set points for DIN100B. 4 ON and OFF (CH A) and 3 ON and OFF (CH B) pairs of set points for DIN200B. Individual programs on each day of the week. Minimum setting is 1 minute. CATALOG NO. 45.00 FEATURES 4 35.2 5 4 5 Channel A (C1) Channel A (C1) 46.00 60.00 DIGITAL CONTROLS TORK 89 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com Channel A (C1) Output Input TORK 90 SMC SERIES 5401 SERIES SPECIFICATIONS MOMENTARY CONTACT ADAPTER INCREASED AMPERAGE & VOLTAGE SWITCHING 40 AMP CONTACTORS INPUT VOLTAGE: 120VAC, 50/60Hz. TERMINAL RANGE: #12 - #18AWG. OPERATING TEMPERATURE: -31°F to +131°F (-35°C to + 55°C). POWER CONSUMPTION: 6VA max. APPLICATIONS ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R with lockable hasp (see page 153 for dimensions). Converts maintained contacts for pulse switching Timer to latching contactor control Photocell to latching contactor control Signaling CONTACT RATINGS 5401 Lighting loads Exhaust fans Electric and hot water heaters Refrigeration and defrosting 5441 TYPE VOLTAGE RATING Resistive 120-600VAC 50A FLA 120-600VAC 40A Motor 120VAC 240VAC 480VAC 600VAC 3HP 7.5HP 20HP 25HP ORDERING INFO UPC CODE INPUT SUPPLY (VAC) 50/60Hz OUTPUT CONTACTS SMC3D 52011 120 SPDT Momentary CONTACT RATINGS NC Resistive 120VAC 10A 10A General Purpose 120VAC 10A 10A Motor 120VAC 1⁄4HP NC SMC 3D ON RELAY NC NO C 5401 H 120VAC N INPUT 120 VAC OFF RELAY BLACK NC NO C WHITE Control circuit from Time Switch ON PULSE 120VAC NEUTRAL N L C NO AUX LOAD DIGITAL CONTROLS TORK 91 LOAD N LOAD A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com NC H CONTACT 277VAC 480VAC 81021 81022 120VAC 208VAC 277VAC 480VAC Wire B, C the sa NO. AOF CONTACTORS 120 1 120 4 OUTPUT CONTACTS N B 3PST 120VAC 208VAC 277VAC 480VAC Control circuit from Time Switch 24VAC Wire other circuits B, C and D respectively 120 to 480VAC { A N C D C D A Keep low voltage wires inside this compartment. 120VAC 208VAC 277VAC 480VAC B Wire contactors B, C and D the same as A. D B 120VAC 208VAC 277VAC 480VAC Wire other c 3PST C A 24VAC 5441 120 to 480VAC Control circu B Control circuit from Time Switch 120VAC C D Keep low voltage wires inside this compartment. Wire other circuits B, C and D respectively 120VAC 120 VAC SMC 3D ON RELAY OFF RELAY NC NO C NC NO C PUSH ON { N 120VAC COIL VOLTS { TORK DIGITAL CONTROL TERMINAL BLOCK MAINTAINED CONTACT INPUT L 5401 { UPC 120VAC CODE 208VAC 120VAC 208VAC 277VAC 480VAC Control circuit from Time Switch Wire contactors B, C and D the same as A. H REALAY CONTACTOR L CATALOG NO. 5441 PUSH OFF OFF PULSE 120VAC 208VAC 277VAC 480VAC 5 120VAC 208VAC 277VAC 480VAC 120VAC 208VAC 277VAC 480VAC ORDERING 5440INFO N PUSH ON LOW VOLTAGE LATCHING RELAY OR MECHANICALLY HELD CONTACTOR WHITE ENCLOSURE: 5401 - Metal NEMA 3 enclosure. 5441 - Metal NEMA 1 Indoor enclosure (see page 153 for enclosure dimensions). TORK DIGITAL CONTROL TERMINAL BLOCK MAINTAINED CONTACT INPUT NO BLACK EASY WIRING: Includes 120 volt control wiring compartment. 5441 has terminal strip pre-mounted for quick connection. SMC 3D 120VAC, 240VAC Input – Sustained voltage 120VAC WIRING DIAGRAMS 277VAC, 30VDC Momentary Contacts (unpowered) 30 Amps inrush C 5401 CONTACT RATINGS: Can switch up to 40 AMPS per pole from 120VAC to 600VAC, one to three circuits simultaneously. { NO { MOMENTARY OUTPUT: SMC3D provides two dry output contacts. The ON contact provides a 2 second contact closure (pulse) when power is applied to the input contacts. The OFF contact provides a 2 second pulse when power is removed from the input contacts. RATING VOLTAGE WIRING DIAGRAMS FEATURES { TYPE MAINTAINED INPUT: SMC3D accepts maintained input power from any 120 volt control. When power is applied or removed a short contact closure (pulse) is created on the dry output contacts. Coil Data: 120VAC @ 60Hz 6VA Holding/seal; 60VA inrush { FEATURES CATALOG NO. { APPLICATIONS TORK 92 HPS STARTER SPECIFICATIONS FOR HIGH PRESSURE SODIUM LAMPS STARTING AID LINE VOLTAGE: 105 - 347VAC. LAMP VOLTAGE: 55 or 100VAC. TRP SERIES SPECIFICATIONS LOW VOLTAGE SWITCHING TRANSFORMER RELAY POWER PACKS CONTACTS: SPST contacts. CONTACT RATING: 20 Amps Ballast @ 120 or 277VAC. 15 Amps Tungsten @ 120VAC. 1.0 Horsepower @ 120VAC. LAMP WATTAGE: 35 to 400 watts. OPERATING TEMPERATURE: -40°F to +221°F (-40°C to + 105°C). APPLICATIONS LEAD LENGTH: 9 inches. ENCLOSURE: Durable, high temperature Designed to operate as a starting aid, for all H.P.S. ballasts from 35 to 400 watts, with lamp voltage of 55 or 100 volts. Lexan® housing. APPLICATIONS TEMPERATURE RANGE: 0° to 150°F (–18° to 66°C). Pre-wired in metal enclosure. Low voltage switching of line voltage lighting circuits up to 20 Amp ballasts or 15 amp tungsten loads. Also up to 1.0 HP motors for ventilating and exhaust fans. Low voltage switching by digital or mechanical controls for higher amperage loads including those of two different voltages. ORDERING INFO FEATURES SMART VOLTAGE: Delivers appropriate trigger spikes for lamp ignition, then reduces voltage to good lamps. Continues to feed voltage spikes to old or poorly working lamps. CATALOG NO. UPC CODE DESCRIPTION HPS30 81030 High Pressure Sodium Starter BALLAST design, color coded for ease of installation. BLACK RED TAP H.P.S. STARTER WHITE LINE TORK 93 ORDERING INFO CATALOG NO. UPC CODE TRP-1** 82032 TRP-2** 82033 TRP400* 82132 TRP402* 82133 TRP800* 82135 TRP802* 82136 DESCRIPTION Single Transformer Relay Powerpack Single Transformer Relay Powerpack Four Transformer Relay Powerpack Four Transformer Relay Powerpack Eight Transformer Relay Powerpack Eight Transformer Relay Powerpack INPUT VOLTAGE 120VAC 277VAC 120VAC 277VAC 120VAC 277VAC SURGE SUPPRESSOR FOR HIGH ELECTRICAL NOISE EASY INSTALLATION: Universal 3 wire DIGITAL CONTROLS ENCLOSURE: Metal NEMA 1 Indoor enclosure (see page 153 for enclosure dimensions). *Not for use with occupancy sensors. **For replacement parts only. For newer style Transformer Relay Power Pack, see TRP-U on page 116. WIRING DIAGRAMS HIGH GRADE MATERIAL: All components are sealed with high grade die-electric material to protect against contaminants and other adverse environmental conditions. WEIGHT: 7 oz. A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com COMMON CENTER CONTACT LAMP SHELL APPLICATIONS For high electrical noise interference, recommended for all digital controls. ORDERING INFO CATALOG NO. UPC CODE DESCRIPTION 90058-1 81024 Surge Suppressor TORK 94 IN-WALL TIMERS FEATURES QUICK LOOK SS720A SERIES SPECIFICATIONS 24 HOUR OR 7 DAY DIGITAL IN-WALL TIME SWITCH TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 125VAC, 60Hz. WIRE SIZE: #14AWG. OPERATING TEMPERATURE: 32°F to +104°F (0°C to +40°C). APPLICATIONS SS700Z SS721Z SS720A 701A SSA SSA-R24 SS D1060 D212 A C Page No. 99 99 98 101 102 102 103 104 105 106 Timer Type 7 Day Digital 7 Day Digital 7 Day Digital 24 Hour Mechanical Auto OFF Digital Auto OFF Digital Auto OFF Electronic Auto OFF Electronic Auto OFF Mechanical Auto OFF Mechanical Voltage 120/277 120/277 120 120 120/277 24 24/120/ 208-240/277 120 ON 1 min. 1 min. 1 min. 30 min. OFF 1 min. 1 min. 1 min. 30 min. Minimum Settings 5 min-12 hr 5 min-12 hr 10-60 min. 1 min-18 hr 10 min-8 hr 10 min-8 hr 2-12 hr Outdoor security lighting Interior lights for lived-in look Fans and motors Appliances 125/250/277 125/250/277 Various 2 min-12 hr Various 2 min-12 hr ORDERING INFO Manual Override Yes Yes Sunrise/Sunset Yes Yes ON/OFF Set Points 10 Pair 10 Pair Yes Yes SCHEDULING: 7 ON and OFF pairs of set points for individual programs on each day of the week. Minimum setting is 1 minute. 7 Pair 24 Flash Warning TORK 97 Capacitor Capacitor Battery Switch Type SPST SPST SPST Resistive Ratings 16A 16A 15A SPST NEW! CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 60 Hz COLOR SS720A 14017 120 White SS720AA 14018 120 Light Almond RANDOM MODE: Varies ON and OFF times to create "lived in" look when away. Yes Audible Warning Power Outage Backup FEATURES Yes Yes Yes Capacitor Capacitor SPST 15 & 20A 800W/1200W Yes DAYLIGHT SAVING: Manual button push for one hour adjustment. Yes MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CONTACT RATINGS TYPE VOLTAGE RATING General Purpose 120VAC 15A WIRING: Requires a neutral. Resistive 120VAC 15A CLOCK FORMAT: AM/PM. Tungsten 120VAC 15A Motor 120VAC 1HP Electronic Ballast 120VAC 500VA SPDT SPST or SPDT SPST SPST SPST or DPST POWER OUTAGE BACKUP: Rechargeable Ni-MI battery retains time and schedule. 1A 4A or 7.5A 15 20/10/10A 20/10/10A WALL PLATE: Supplied with standard single gang decorator wall plate. TORK 98 SS700Z & SS721Z SERIES BACKUP WITHOUT BATTERY, ECO FRIENDLY! NEW! SUNSET / SUNRISE, ASTRONOMIC 7 DAY IN-WALL TIMER SS700Z SERIES TIMING ACCURACY: Line frequency. energy RATING INPUT VOLTAGE: 120/277VAC, 50/60Hz. Resistive 16A 120/277VAC 16A WIRE SIZE: #12AWG input/output - #16AWG 3-way (remote). Ballast 10A 120/277VAC 13A Tungsten 8A 120VAC 8A Pilot Duty 360VA 120VAC 720VA Motor 1⁄2HP 120VAC 1HP CALIFORNIA Title 24 ASHRAE 90.1 Outdoor security lighting Interior lights for lived-in look Fans and motors Appliances SS721Z SERIES VOLTAGE TYPE OPERATING TEMPERATURE: 32°F to +104°F (0°C to + 40°C). responsible APPLICATIONS CONTACT RATINGS SPECIFICATIONS With wall plate (not included) RATING WIRING DIAGRAMS ORDERING INFO CONTACT RATINGS CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 50/60 Hz SWITCH TYPE COLOR SS700Z 14019 120/277 SPST White SS700ZA 14020 120/277 SPST Light Almond SS721Z 14027 120/277 SPST White SS721ZA 14028 120/277 SPST Light Almond FEATURES SCHEDULING: 10 ON and OFF pairs of set points for individual programs on each day of the week. 11 day groups speed programming. Minimum setting is 1 minute. ASTRONOMIC: Sunset and sunrise times are adjustable from 10°- 60° Northern or Southern latitudes. Can be individually offset +/- 1-240 minutes for earlier or later operation. RANDOM MODE: Varies ON and OFF times to create lived in look when away. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. MANUAL MODE: Does not run programs until set to AUTO (automatic) mode. VACATION MODE: No operation when away. WIRING DIAGRAM: INSTALLATION SS721Z EASY WIRING: SS700Z does not require a neutral, can be used as a 3-way switch. SS721Z Requires a neutral, can be used as a 3-way switch. H COMMERCIAL GRADE SPECS: Control lighting contactors and 277VAC loads. Compatible with CFL lamps. Blue Red Black Load White CLOCK FORMAT: AM/PM. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 2 days of real time backup. Black N N Ground WIRING DIAGRAM: THREE-WAY INSTALLATION SS721Z Connect a wire inside the gang-box between Traveler A and Hot. ORDERING INFO Green Black Blue Black Traveler A H Black Red Traveler B Load White N N Ground Green IN-WALL TIMERS TORK 99 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 100 701A & 711A SERIES SPECIFICATIONS SPECIFICATIONS 24 HOUR IN-WALL TIME SWITCH INPUT VOLTAGE: 125VAC, 60Hz. WIRE SIZE: #14AWG. SSA SERIES SPECIFICATIONS DIGITAL AUTO OFF IN-WALL TIME SWITCH TIMING ACCURACY: .002%. INPUT VOLTAGE: 120/277 VAC, 50/60Hz. OPERATING TEMPERATURE: 32°F to +104°F (0°C to +40°C). APPLICATIONS WIRE SIZE: #18AWG. APPLICATIONS Offices, meeting rooms, library aisles Stock and equipment rooms Exhaust fans – work areas, utility rooms, bathrooms Hot tub heaters and circulating pumps Timed override lighting and HVAC for after hours and for loads controlled by electromechanical or digital time switches. Porch or patio Doorway Pool Outdoor security lighting ORDERING INFO CATALOG NO. UPC CODE INPUT SUPPLY SSA100 14010 120/277 VAC SSA200 14011 120/277 VAC SSA100R-24 14014 24VAC/24VDC SSA200R-24 14015 24VAC/24VDC LCS115M 82082 OPERATING TEMPERATURE: 0°F to +100°F (-17°C to +37°C). TIME SETTINGS OUTPUT CONTACTS Minutes: 5, 15, 30 Hours: 1, 3, 6, 9, 12 Minutes: 10, 20, 40 Hours: 1, 11⁄2, 2, 4, 8 Minutes: 5, 15, 30 Hours: 1, 3, 6, 9, 12 Minutes: 10, 20, 40 Hours: 1, 11⁄2, 2, 4, 8 Momentary Switch for Override (white) SPST SPST SPDT SPDT SPST CONTACT RATINGS CLOCK FORMAT: AM/PM marked on dial. WALL PLATE: Supplied with single gang wallplate. INPUT SUPPLY (VAC) 60 Hz 8-IN-1 TIMING: Choose from 8 preset ON intervals. COLOR 701A 10113 125 White 701AA 10118 125 Light Almond 711A 10114 125 White MANUAL SCROLL-UP: Option allows adjustment in 10 minute intervals. FLASH WARNING: Optional flicker feature turns load off for 1 second, 2 minutes before end of timed cycle and again 1 minute before end of timed cycle. CONTACT RATINGS TYPE VOLTAGE General Purpose 800W 800W 1200W 1⁄6HP Pilot Duty 30V 1V min. 120VAC 30V 1V min. 240VA 1A 100µA RATING 701A SERIES 711A SERIES 125 VAC 20A 15A Resistive 125 VAC 20A 15A Tungsten 125 VAC 1500W 1250W Motor 125 VAC 1 HP 1⁄2HP Ballast SSA100/200 SSA100/200R-24 WIRING DIAGRAMS SSA100/200 AUDIBLE WARNING: Optional beep will sound every 12 seconds during the last 2 minutes of timed cycle. BLACK HOT GREEN 120V GROUND GREEN /YELLOW 277V GROUND RED TAMPER RESISTANT: Time ON interval preset hidden behind wall plate. RED EASY SET: Dip switches provide quick set-up of timing and options. EASY WIRING: No neutral needed, great for retrofit. BACKLIT DISPLAY: Numerical read-out of time remaining includes graphic bar showing time remaining in 10% increments. Stands out strongly in lighted and dark areas. BLACK ORANGE BLUE GREY REMOTE OVERRIDE (+) 24VAC or (–) VDC NC C NO YELLOW YELLOW SSA200R-24 USING TRP TRANSFORMER RELAY POWERPACK BLACK ORANGE BLUE GREY REMOTE OVERRIDE NC C NO YELLOW YELLOW LOW VOLTAGE 20 AMP LOAD L RED WALL PLATE: Supplied with white standard single gang decorator wall plate. SSA-R24: Offers low voltage control with SPDT output and includes momentary input. NEUTRAL LOAD RED WIRING: Requires a neutral. Motor 120VAC 120VAC 277VAC 120VAC RED BLACK BLUE N BLACK VACATION MODE: Set timer OFF with no change of tripper settings. Tungsten RED BYPASS SWITCH: Slide switch for ON, OFF, or TIMER (automatic) operation. NEW! UPC CODE RATING TORK TRP SCHEDULING: Minimum ON setting is 30 minutes. Dial has 48 captive trippers. CATALOG NO. VOLTAGE WHITE ORDERING INFO FEATURES TYPE FEATURES L IN-WALL TIMERS TORK 101 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 102 SS SERIES SPECIFICATIONS AUTO OFF IN-WALL TIME SWITCH TIMING ACCURACY: ±5% @ 60° to 80°F. D SERIES SPECIFICATIONS SPECIFICATIONS NEW! ELECTRONIC AUTO OFF IN-WALL TIME SWITCH TIMING ACCURACY: Line voltage. INPUT VOLTAGE: 120VAC, 60Hz. INPUT VOLTAGE: 24/120/208-240/277VAC, 50/60Hz. WIRE SIZE: #14AWG. OPERATING TEMPERATURE: 32°F to 122°F (0°C to 50°C). WIRE SIZE: #18AWG. OPERATING TEMPERATURE: 0°F to +100°F (-17°C to +37°C). APPLICATIONS APPLICATIONS Whole house fans Indoor/Outdoor lighting Bathroom fans and lights Self storage Bathroom fans and lights Indoor/Outdoor lighting Storage areas Hospitality areas ORDERING INFO ORDERING INFO FEATURES VARIABLE TIMING: Choose from 1 minute to 18 hours. FLASH WARNING: “F” suffix models with flicker feature turns load off for 1⁄2 second, 2 minutes before end of timed cycle and again 1 minute before end of timed cycle. AUDIBLE WARNING: “B" suffix model will buzz that every 12 seconds during the last 2 minutes of timed cycle. TAMPER RESISITANT: Time ON interval preset is hidden behind wall plate. EASY SET: Small screw driver adjustment provides quick set-up of timing. EASY WIRING: No neutral needed, great for retrofit. CATALOG NO. INPUT SUPPLY (VAC) 50/60Hz WARNING BEFORE TIME OUT SWITCH TYPE SS20 14005 24/120/208-240/277 None Single pole SS20F 14008 24/120/208-240/277 *Flicker Single pole SS13F 14007 24/120/208-240/277 *Flicker 3-way SS13B 14006 24/120/208-240/277 **Beep 3-way *Flicker feature turns load OFF for ½ second, 2 minutes before end of timed cycle and again 1 minute before end of timed cycle. **Beep feature will begin a ½ second audible warning every 12 seconds during the last 2 minutes of timed cycle. CONTACT RATINGS TYPE SS13F & SS13B 3-WAY: SS13 SERIES replaces standard 3-way switch with no re-wiring. COLOR: White. UPC CODE SS20 & SS20F FEATURES VARIABLE TIMING: Button push changes time ON setting. D1060M: 10, 20, 30, 60 minute. D212H: 2, 4, 8, 12 hour. LED DISPLAY: Indicator moves to new range as timer counts down. TAMPER RESISTANT: Time ON interval preset. EASY SET: No adjustments, just wire and go! WIRING: Requires a neutral. THREE COLORS: Ivory, Light Almond, White. MINIMUM LOAD CONTACT RATINGS VOLTS WATTS .25-4.0A Resistive .25-4.0A Ballast* .25-4.0A Tungsten 1⁄8HP @ 120VAC 1⁄3HP @ 240VAC .50-7.25A Resistive .50-7.25A Ballast* .50-4.0A Tungsten 1⁄6HP @ 120VAC 1⁄2HP @ 204VAC 24 120 208 240 277 24 120 208 240 277 6 30 50 60 70 12 60 105 120 150 CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 60Hz TIME SETTINGS OUTPUT CONTACTS D212H 14021 120 Ivory 2, 4, 8, 12 HOURS D212HA 14022 120 Light Almond 2, 4, 8, 12 HOURS D212HW 14023 120 White 2, 4, 8, 12 HOURS D1060M 14025 120 Ivory 10, 20, 30, 60 MINUTES D1060LA 14024 120 Light Almond 10, 20, 30, 60 MINUTES D1060MW 14025 120 White 10, 20, 30, 60 MINUTES CONTACT RATINGS TYPE VOLTAGE RATING General Purpose 120VAC 15A Resistive 120VAC 1000W Tungsten 120VAC 1000W Motor 120VAC 1⁄4HP *Not compatible with compact fluorescent lamps (CFL) and electronic fluorescent ballasts. IN-WALL TIMERS TORK 103 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 104 A SERIES SPECIFICATIONS SPRINGWOUND AUTO OFF IN-WALL TIME SWITCH INPUT VOLTAGE: 125/250/277VAC, 50/60Hz. TERMINAL SIZE: #12AWG. C SERIES SPECIFICATIONS COMMERCIAL STYLE SRINGWOUND AUTO OFF IN-WALL TIME SWITCH INPUT VOLTAGE: 125/250/277VAC, 50/60Hz. TERMINAL SIZE: #12AWG. OPERATING TEMPERATURE: 32°F to 122°F (0°C to 50°C). OPERATING TEMPERATURE: 32°F to 122°F (0°C to 50°C). ORDERING INFO APPLICATIONS Whole house fans Indoor/Outdoor lighting Bathroom fans and lights Self storage CATALOG UPC NO. CODE 15 MINUTE MAX. Wallplate not included A515MH 15020 A515MHW 15120 A515M 15013 A515MW 15113 A515MA 15127 HOLD FEATURE With Hold APPLICATIONS COLOR Ivory White Ivory No Hold Wallplate included Ventilating fans HVAC Whirlpools Self storage Motors and pumps White Light Almond 30 MINUTE MAX. A530MH 15021 A530MHW 15121 A530M 15014 A530MW 15114 CONTACT RATINGS FEATURES TYPE VARIABLE TIMING: Twist knob for time ON setting. Time ON lengths from 15 minutes to 12 hour vary by model. VOLTAGE RATING 125VAC 250VAC 277VAC 125VAC 250VAC 277VAC 20A 10A 10A 20A 10A 10A 125VAC 7A Resistive Inductive HOLD FEATURE: Some models have position for constant ON. Tungsten EASY SET: No adjustments. Just wire and go! EASY WIRING: No neutral required. Great for retrofit! Use as single or in multi-gang box with no de-rating. 125VAC 250VAC Motor 1HP 2HP A530MA 15022 A560MHW 15122 A560M 15015 A560MW 15115 A502HHW 15123 A502H 15016 A502HW 15116 3 9 6 0 0 12 12 3 9 6 9 A506HHW 15125 A506H 15018 9 A506HW 15118 With Hold No Hold Ivory White With Hold No Hold With Hold No Hold FEATURES VARIABLE TIMING: Twist knob for time ON setting. Time ON lengths from 15 minutes to 12 hour vary by model. Ivory HOLD FEATURE: Some models have position for constant ON. White EASY SET: No adjustments. Just wire and go! White EASY WIRING: No neutral required. Great for retrofit! Ivory SWITCH TYPE: SPST, except C460M and C412H – DPST White COLOR: Metal-brushed aluminum. White WALL PLATE: Includes real metal wall plate with screw mounting, to add extra security for commercial applications. Ivory TYPE VOLTAGE RATING 125VAC 250VAC 277VAC 125VAC 250VAC 277VAC 20A 10A 10A 20A 10A 10A Tungsten 125VAC 7A Motor 125VAC 250VAC 1HP 2HP Resistive Inductive 3 A512HH 15026 A512HHW 15126 A512H 15019 A512HW 15119 9 0 3 21 CAUTION: This timer is not to be used in precision timing applications where inaccurate timing could have dangerous consequences (i.e. sun lamp, sauna, etc.). 6 15501 HOLD FEATURE No Hold 30 MINUTE MAX. C530M 15503 No Hold 60 MINUTE MAX. NEW! C560M 15505 No Hold C560MH 15506 With Hold C460M* 15011 No Hold 2 HOUR MAX. C502H 15507 No Hold 6 HOUR MAX. C506H 15511 No Hold 12 HOUR MAX. 21 T OR K 1 C515M White With Hold Ivory NEW! White C512H 15513 No Hold C512HH 15514 With Hold C412H* 15010 No Hold *DPST switch type. 1 2 CATALOG UPC NO. CODE 15 MINUTE MAX. 12 HOUR MAX. 0 1 6 2 Light Almond ORDERING INFO CONTACT RATINGS 1 T OR K 2 White 6 HOUR MAX. POT 2 0 12 No Hold 2 HOUR MAX. POT 0 White Ivory 15128 A560MH COLOR: Ivory, Light Almond, White. 12 Ivory 60 MINUTE MAX. SWITCH TYPE: SPST. WALL PLATE: Fits standard or decorator style wall plates, see below (not included). With Hold 9 No Hold Ivory White CAUTION: This timer is not to be used in precision timing applications where inaccurate timing could have dangerous consequences (i.e. sun lamp, sauna, etc.). All A Series timers have SPST switch type. IN-WALL TIMERS TORK 105 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 106 OCCUPANCY SENSORS OSWS SERIES SENSOR TECHNOLOGY & PLACEMENT GUIDE TECHNOLOGY PIR AND ULTRASONIC A Passive Infrared Sensor (PIR sensor), is a device that measures infrared radiation (IR), or heat, from objects in its field of view. Because it only receives information, it is considered passive. The IR sensor views a human body as an IR generating object. The lens of the occupancy sensor breaks up the field of view into IR sensitive bands. The occupancy sensor is designed to only react when heat is sensed moving from band to band. For PIR occupancy sensors to work object must have direct “line of sight” to the PIR sensor. PLACEMENT GUIDELINES PIR SENSOR, DECORATOR STYLE IN-WALL OCCUPANCY SENSOR • Designed for ceiling mounting at a height of 8-10 feet (mounting sensor at greater heights decreases the sensitivity to motion, while lower mounting height will decrease range). • The sensor needs a visually unobstructed view of the normally occupied workspace and entry door(s). • Avoid sensor placement with a direct view out a doorway. Placing the sensor offset from the center and away from the door is recommended. Both technologies show higher sensitivity closer to the sensor to allow small • If the occupant cannot see a PIR sensor from their normal work movements to be noticed. Sensitivity reduces further away from the sensor and position, the sensor will not be able to detect their presence. may require a walking step to activate the sensor. • File cabinets, partitions, or walls are typical types of obstructions. If there are other obstructions between the sensor and the occupant, an ultra-sonic or dual technology ceiling sensor is recommended. • When the light level feature is used, mount within 15 feet of the widows or skylight and avoid mounting the sensor close to lighting WALL SENSOR fixtures. A Wall Switch Sensor provides a 180° coverage pattern, extending outward • Place the sensor no closer than 5 feet to an HVAC airCEILING duct whenAND usingWALL OCC SENSOR SENSING PATTERNS CEILING AND WALL OCC SENSOR SENSING PATTERNS from the sensor. This will allow for instant turn ON when an occupant enters the dual technology sensors. space. Total area covered will be over 400 square feet. • Open office designs encourage placement of the sensors to allow overlapping coverage of small motion range and a clear view into • Proper placement gives the sensor a clear line of sight to the entry door each cubicle. Walking step motion may cover the entry to the space. without viewing the hallway. Dual technology units provide added sensitivity to small motion. • The occupant must be able to see the sensor from their normal work position otherwise the sensor will not be able to detect their presence. • For offices where there are other obstructions between the sensor and the occupant or the entry door, a ceiling sensor is required. An Ultrasonic Sensors (US sensor) is a technology that works on a principle similar to radar or sonar. It is an active technology that sends and receives. It emits an inaudible high-frequency sound wave and evaluates the echo which is received back after bouncing around in the room. This allows the sensor to evaluate the whole room and can “look” over walls and obstructions to identify movement. PLACEMENT GUIDELINES CEILING AND WALL OCC SENSOR SENSING PATTERNS CONTACT RATINGS: OSWS9P-120: 1000W Ballast, 800W Incandescent, 1⁄6HP at 120VAC. OSWS9P-277: 1800W Ballast at 277VAC. OSWS9PD & OSWS9PDM: 1000W Ballast, 800W Incandescent, 1⁄6HP at 120VAC, 1800W Ballast at 277VAC. responsible energy CALIFORNIA Title 24 CEILING SENSOR A Ceiling Sensor provides a 360° coverage pattern of up to 1200 square feet when using passive infrared only. When using dual technology the coverage pattern extends to over 2000 square feet. Barriers within the space that block line-of-sight to sensor detection will decrease coverage area when using passive infrared by itself, ultrasonic dual technology will allow the sensor to get around the obstructions. SPECIFICATIONS ASHRAE 90.1 APPLICATIONS ADJUSTABLE TIME DELAY: 30 seconds - 30 minutes. Offices and hotels Classrooms Conference rooms Lavatories Hallways OPERATING TEMPERATURE: 32° to 131°F (0° to 55°C). MOUNTING: Box mount. FEATURES OSWS9P-120, OSWS9P-277 & OSWS9PD: OPERATION: Automatic ON and automatic OFF based on occupancy detection. OFF DELAY: Selectable from 30 seconds to 30 minutes. MANUAL OVERRIDE: Includes ON and OFF switch. EASY WIRING: No neutral required. Great for retrofit. OSWS9PD ALSO INCLUDES: SENSITIVITY ADJUSTMENT: For PIR range. DAYLIGHTING MODE: Adjustable level to keep lights OFF even when occupancy is sensed if adequate light exists in the room from windows or skylights. ORDERING INFO CATALOG NO. UPC CODE DESCRIPTION OUTPUT CONTACTS OSWS9P-120 82077 PIR in-line wall switch 120VAC OSWS9P-277 82078 PIR in-line wall switch 277VAC OSWS9PD 82079 120/277VAC OSWS9PDM 82080 PIR in-line wall switch with ambient light sensor PIR in-line wall switch manually activated WIRING & COVERAGE DIAGRAMS Wall Mounting Box OSWS9PDM - VACANCY SENSOR: OPERATION: Manual push button on and then automatic OFF. LINE (Black) OFF DELAY: Selectable from 30 seconds to 30 minutes. LOAD (Red) SENSITIVITY ADJUSTMENT: For PIR range. DAYLIGHTING MODE: Adjustable level to keep lights OFF even when occupancy is sensed if adequate light exists in the room from windows or skylights. MANUAL OVERRIDE: Includes ON and OFF switch. 120/277VAC GND (Green) Top and Side Coverage Pattern Diagrams EASY WIRING: No neutral required. 35' 16' 180° Coverage 15° 4.0' 15° 35' TORK 109 TORK 110 OSC15PLS SPECIFICATIONS PIR SENSOR, WITH AMBIENT LIGHT OVERRIDE, MULTI-VOLTAGE INTEGRAL POWERPACK, CELING MOUNTED OCCUPANCY SENSOR VOLTAGE: 120 - 347VAC. ADJUSTABLE LIGHT LEVEL: 5FC - 200FC. responsible energy CALIFORNIA Title 24 ASHRAE 90.1 ADJUSTABLE TIME DELAY: 30 seconds 30 minutes (DIP switch). TEST MODE: 5 seconds, upon initial power-up or DIP switch reset. APPLICATIONS PIR COVERAGE: 1200 sq. ft. Offices and hotels Classrooms Conference rooms Lavatories Hallways sensitivity adjustment: Full or 50% low (DIP switch). operating temperature: 32° to 131°F (0° to 55°C). mounting: Ceiling or box mount. contacts: SPST dry contacts. FEATURES contact ratings: 800W Incandescent, 1000W ballast at 120VAC. 1800W Ballast at 277VAC. 2200W Ballast at 347VAC. OPERATION: Automatic ON and automatic OFF based on occupancy detection. OSC12PL & OSC5PL SPECIFICATIONS VOLTAGE: 24VDC. PIR SENSOR CELING MOUNTING OCCUPANCY SENSORS UPC CODE INPUT SUPPLY COVERAGE (FEET) DESCRIPTION OSC15PLS 82076 120-347VAC 1200 WHITE WIRING & COVERAGE DIAGRAMS OSC15PLS SENSOR N LOAD WHITE (NEUTRAL) BLACK (LINE) RED RED ADJUSTABLE LIGHT LEVEL: 10FC - 150FC. Offices Classrooms Conference rooms Lavatories Hallways ADJUSTABLE TIME DELAY: 5 seconds - 30 minutes (DIP switch). TEST MODE: 5 seconds, upon initial power-up or DIP switch reset. PIR COVERAGE: 1200 sq. ft. OSC5PL / OCCUPANCY SENSOR ASSORTED SENSING PATTERNS OSC5PL / OCCUPANCY SENSOR ASSORTED SENSING PATTERNS FEATURES 18ft SENSITIVITY ADJUSTMENT: Full or 50% low (DIP switch). 18ft MOUNTING: Ceiling or box mount. OPERATION: Automatic ON and automatic OFF based on occupancy detection. DAYLIGHTING MODE: Selectable to keeps lights off when occupancy is sensed if adequate light exists in the room from windows or skylights. CATALOG NO. POWER SUPPLY: TRP-U Power Pack (up to 6 units). CALIFORNIA Title 24 APPLICATIONS OFF DELAY: Selectable from 30 seconds to 30 minutes. POWER SWITCHING: Built-in power pack for direct line voltage control. energy ASHRAE 90.1 OFF DELAY: Selectable from 30 seconds to 30 minutes. ORDERING INFO CURRENT CONSUMPTION: 9mA. responsible OPERATING TEMPERATURE: 32° to 131°F (0° to 55°C). ORDERING INFO 12ft COVERAGE (FEET) 12ft ECOSETTING: Learns typical use patterns and adjusts the OFF delay for the most efficient time. CATALOG NO. UPC CODE INPUT SUPPLY WALK-THROUGH MODE: Selectable to turn lights OFF after only 3 minutes. If no activity is detected after 30 seconds of occupancy detection, lights turn OFF. OSC5PL 82083 24VDC 500 White OSC12PL 82081 24VDC 1200 White TRP-U 82030 120/277VAC DAYLIGHTING MODE: Selectable to keep lights OFF when occupancy is sensed if adequate light exists in the room from windows or skylights. LCS115M 82082 DESCRIPTION Power Pack Momentary Switch COVERAGE DIAGRAMS PRESENTATION MODE: Optional MANUAL OFF by an accessory wall switch (LCS115M). Sensor will keep lights OFF while movement in room is detected, then return to automatic ON after 5 minutes. DIP SWITCH Sensitivity Time Delay 1 50% VACANCY MODE: Optional MANUAL ON by an accessory wall switch (LCS115M) and then automatic OFF. 100% Walk Through 3 Audible Alert 4 Enabled Visible Alert Vacancy 6 Disabled Enabled WARNING BEFORE OFF: Optional visual flash warning and/or audible beep warning one minute before turn OFF. Enabled 20 Minutes 25 Minutes Hold ON 30 Minutes Disabled OFF ON 8 Disabled 15 Minutes Enabled 7 Disabled 30 Seconds 5 Minutes 10 Minutes 5 Disabled MANUAL OVERRIDE: Optional manual control by an accessory wall switch (LCS115M) for ON and OFF. 2 5 Sec/EcoSet Factory Setting 9 Enabled OSC5PL OSC12PL PLUG TERMINAL: Quick disconnect for sensor. POWER SWITCHING: Transformer relay power pack (TRP-U) required to power sensor and provides line voltage switching. (see page 116 for product information). OCCUPANCY SENSORS TORK 111 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com 22 6.7 11 7 3 3 7 11 TORK 112 OSC2OUP DUAL TECHNOLOGY CELING MOUNTED PIR/ULTRASONIC OCCUPANCY SENSOR SPECIFICATIONS VOLTAGE: 24VDC. energy CALIFORNIA Title 24 ASHRAE 90.1 APPLICATIONS PIR COVERAGE: 1500 sq. ft. (adjustable). SENSITIVITY ADJUSTMENT: Individual setting range for ultrasonic of 50% and PIR of 75%. ULTRASONIC OUTPUT: 32Hz MOUNTING: Ceiling or box mount. OPERATION: Automatic ON and automatic OFF based on occupancy detection. OFF DELAY: Selectable from 8 to 40 minutes. ECOSETTING: Learns typical use patterns and adjusts the OFF delay for the most efficient time. POWER SWITCHING: Transformer relay power pack (TRP-U) is required to power sensor and provide line voltage switching (see page 116 for product information). ADJUSTABLE TIME DELAY: 8 - 40 minutes. US COVERAGE: 2000 sq. ft. (adjustable). FEATURES TORK 113 VOLTAGE: 24VDC. responsible energy CALIFORNIA Title 24 ASHRAE 90.1 APPLICATIONS HUMIDITY: 0 to 95% R.H. non-condensing for indoor use only. OFF DELAY: Selectable from 8 to 40 minutes. ORDERING INFO CATALOG NO. UPC CODE INPUT SUPPLY COVERAGE (FEET) DESCRIPTION OSCS20UP 82075 24VDC 2000 ft US 1500 ft PIR White TRP-U 82030 120/277VAC Power Pack A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com POWER SWITCHING: Transformer relay power pack (TRP-U) is required to power sensor and provide line voltage switching (see page 116 for product information). ADJUSTABLE TIME DELAY: 8 - 40 minutes. SENSITIVITY ADJUSTMENT: Manual setting range of 50%. ULTRASONIC OUTPUT: OSC5U: 40kHz OSC10U/OSC20U: 32kHz MOUNTING: Ceiling or box mount. OPERATING TEMPERATURE: 32° to 104°F (0° to 40°C). HUMIDITY: 0 to 95% R.H. non-condensing for indoor use only. ECOSETTING: Learns typical use patterns and adjusts the OFF delay for the most efficient time. MOTION INDICATION: Green for ultrasonic motion. Indicator may be disabled. POWER SUPPLY: TRP-U Power Pack (up to 4 units). US COVERAGE: 2000 sq. ft. (adjustable). FEATURES OPERATION: Automatic ON and automatic OFF based on occupancy detection. CURRENT CONSUMPTION: 33mA. TEST MODE: 8 seconds, upon initial power-up for 1 hour. Offices and hotels Classrooms Conference rooms Lavatories Hallways OPERATING TEMPERATURE: 32° to 131°F (0° to 55°C). COVERAGE DIAGRAMS OCCUPANCY SENSORS SPECIFICATIONS ULTRASONIC, CEILING MOUNTING OCCUPANCY SENSORS POWER SUPPLY: TRP-U Power Pack (up to 3 units). TEST MODE: 8 seconds, upon initial power-up for 1 hour. Offices and hotels Classrooms Conference rooms Lavatories Hallways MOTION INDICATION: Red for infrared motion, Green for ultrasonic motion. Indicators may be disabled. CURRENT CONSUMPTION: 33mA. responsible OSC SERIES ORDERING INFO CATALOG NO. UPC CODE INPUT SUPPLY COVERAGE (FEET) DESCRIPTION OSC5U 82072 24VDC 500 SQ FT White OSC10U 82073 24VDC 1000 SQ FT White OSC20U 82074 24VDC 2000 SQ FT White TRP-U 82030 120/277VAC Power Pack COVERAGE DIAGRAMS TORK 114 ELS TRP-U SPECIFICATIONS INDOOR LIGHT LEVEL ELECTRONIC CCUPANCY SENSOR responsible energy VOLTAGE: 24VDC. ASHRAE 90.1 LOAD REQUIREMENTS: Ballast 20amp @120/277VAC. Incandescent 20amp@120VAC. Motor 1HP @120/240VAC. Output 150mA @24VDC (with relay connected). POWER SUPPLY: TRP-U Power Pack (up to 4 units). operating temperature: 50° to 104°F (10° to 40°C). APPLICATIONS mounting: Ceiling or box mount. Offices Classrooms Conference rooms Hallways LOW VOLTAGE INPUT: Control ON: 12 - 24VDC Hold ON: 12 - 24VDC Hold OFF: 12 - 24VDC Power and switching for occupancy sensors Power and switching for SSA R-24 series BAS input compatible Demand shedding applications Device override to hold on Momentary switched override Low voltage 3-way wiring FEATURES DAYLIGHTING CONTROL: Turns OFF when sufficient daylight present. ADJUSTABLE LIGHT LEVEL: 10FC - 250FC (DIP switch). FEATURES EASY MOUNTING: Low voltage Class 2 wiring allows recommended mounting about 3 feet from daylight sources. OPERATION: Switches line voltage loads ON/OFF based on a contact closure from an occupancy sensor, AUTO OFF switch, or relay. PRESET ON DELAY: 30 seconds prevents false triggering. VOLTAGE: 120/230/277VAC, 50/60Hz. CURRENT CONSUMPTION: 9mA. CALIFORNIA Title 24 APPLICATIONS ADJUSTABLE OFF DELAY: Set from 3 to 15 minutes. SPECIFICATIONS INTELLEGENT POWER PACK ORDERING INFO CATALOG NO. UPC CODE INPUT SUPPLY DESCRIPTION ELS-1 82049 24VDC Indoor Daylight Sensor TRP-U 82030 120/277VAC Power Pack operating temperature: 32° to 131°F (0° to 55°C). ORDERING INFO INTELLEGENT INPUT: Three additional input wires: 1. Hold OFF for demand shed control. 2. Hold ON override of local devices such as sensors. 3. Momentary switch input for remote override. CATALOG NO. UPC CODE INPUT SUPPLY DESCRIPTION TRP-U 82030 120/277VAC Power Pack MULTI-VOLTAGE: Tri-voltage input for flexibility. LCS115M 82082 QUICK MOUNTING: Snaps into 1⁄2" box KO. WIRING DIAGRAMS MOUNTING: Box mount to 1⁄2" KO. Momentary Switch WIRING DIAGRAMS ON 1 2 3 4 5 6 7 Power Pack 277V Model TRP2 or Power Pack 120V Model TRP1 New Extension Box Existing Junction Box TRP-U LOW VOLTAGE WIRING New Cover With 1/2 K.O. Provision PHOTO SENSOR ORIENTATION ARROW UNDER IVORY COVER PROGRAMMABLE 7-SECTION SLIDE SWITCH FOOT CANDLE SELECTION* + 1 2 3 4 56 FOR7 SLIDE FOOT CANDLE #1 10FC Warehouse #2 25FC #3 50FC #4 75FC Corridors Machine equipment display showroom (such as automobile and farm equipment) LOBBY (such as airport waiting area). Classrooms, common office areas #5 100FC Drafting rooms #6 150FC Retail display areas 250FC High critical areas, product sorting and grading, paint quality control. #7 Bend Tabs After Inserting in K.O. Hole New Extension Box Only Used When Low Voltage Wiring Has to be Enclosed *Slide only one switch to ON for selection, all other switches remain OFF. OCCUPANCY SENSORS TORK 115 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 116 PLUG-IN TIMERS 400A SERIES 400D SERIES INDOOR GENERAL PURPOSE 1875W MECHANICAL MULTIPLE ON/OFF TIMERS INDOOR GENERAL PURPOSE 1800W DIGITAL PROGRAMMABLE ON/OFF TIMERS NEW! responsible energy CALIFORNIA Title 24 ASHRAE 90.1 401A APPLICATIONS 460D APPLICATIONS 405A Lamps, radios, televisions Appliances Automatically turn ON/OFF items in the home, gives the home a "lived in" look while away. Lamps, radios, televisions Appliances NEW! 455D Automatically turn ON/OFF items in the home, gives the home a "lived in" look while away. 402A FEATURES 454D NEW! 422A FEATURES 457Z REPEAT SCHEDULE: Daily. REPEAT SCHEDULE: 7 day programming. VARIABLE TIMING: Multiple ON/OFF times. VARIABLE TIMING: 460D, 454D, 455D: Manual Daylight Savings adjustment. Random mode for lived-in look. Manual Override ON/OFF. ON/OFF: Manual ON/TIMER switch. ENERGY SAVINGS: Works with CFLs and LED lamps. 403A 457Z: Turns ON at Sunset; turns OFF at Sunrise or other times; automatic DST adjustment; Random Mode for lived-in look; Manual Override ON/OFF. BACKUP: Battery back-up. ENERGY SAVINGS: Works with CFLs and LED lamps. ACCURACY: Digital accuracy to 1 minute. ORDERING INFO CATALOG NO. UPC CODE 401A 16001 402A 16002 403A 16013 405A 16014 422A 16019 ORDERING INFO RATINGS 125 VAC, 15A, 1875W Resistive 125VAC, 10A, 1250W Tungsten 125VAC, 1⁄3HP 125VAC 15A, 1875W Resistive 125VAC 500W Tungsten 125VAC TV-4 NO. OF OUTLETS ( ) TYPE OF PLUG DESCRIPTION VARIABLE TIMING SEGMENTS CATALOG NO. UPC CODE 1 Polarized Multiple ON/OFF Lighting Timer 15 minute 460D 16017 1 Grounded Heavy Duty 24 hour Timer 15 minute 454D 16009 1 Polarized Powerful & Compact Automatic Timer 30 minute 455D 16015 2 Grounded Heavy Duty 15 AMP Automatic Timer 15 minute 1 Grounded Heavy Duty 24 hour 15AMP Timer 30 minute NOTE: " " = Indicates outlet location. 457Z 16016 RATINGS 120VAC, 15A, 1800W General Purpose 120VAC, 15A, 1800W Resistive 120VAC, 1000W Tungsten 120VAC, 1⁄3HP, TV-5 120VAC, 15A, 1800W General Purpose 120VAC, 15A, 1800W Resistive 120VAC, 960W Tungsten 120VAC, 1⁄3HP TV-5 NO. OF OUTLETS ( ) TYPE OF PLUG DESCRIPTION 1 Polarized Daily Programmable Digital Timer 24 ON/OFFs VARIABLE TIMING SEGMENTS 1 Grounded Daily Programmable Digital Timer Different schedule for each day of the week. 2 Grounded Daily Programmable Digital Timer Multiple ON/OFFs 20 ON/OFFs 2 Grounded Ultimate Plug-In 2-Outlet Timer Different schedule for each day of the week. ON at Sunset OFF at Sunrise NOTE: " " = Indicates outlet location. PLUG-IN TIMERS TORK 119 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 120 600D SERIES 600A SERIES OUTDOOR NEW! GENERAL PURPOSE 1875W 7 DAY DIGITIAL WITH PHOTOCELL, 7 DAY DIGITAL OUTDOOR TIMERS OUTDOOR GENERAL PURPOSE 1875W MECHANICAL PLUG-IN PHOTOCELL COUNTDOWN TIMERS APPLICATIONS responsible energy CALIFORNIA Title 24 ASHRAE 90.1 Photocell APPLICATIONS Landscape or Christmas lighting Controls small pumps, fountains, motors Landscape and Christmas lighting Control small pumps, fountains, motors, etc. Energy saving 601A 602A 621D & 631D (621D without photocell) 611A 611D FEATURES FEATURES REPEAT SCHEDULE: Daily. REPEAT SCHEDULE: 7 day programming. VARIABLE TIMING: Multiple ON/OFFs, Manual ON/ TIMER switch. VARIABLE TIMING: Manual Daylight Savings adjustment. Random mode for lived-in look. Manual ON/TIMER switch. Multiple ON/OFF for each day of the week. PHOTO TIMER: Two styles 652A - Dial setting. ON at dusk and OFF 2, 4, 6, or 8 hours later. 654A - Digital setting. ON dusk and OFF 1 to 9 hours later or at random times. 652A BACKUP: Battery back-up. ACCURACY: Digital accuracy to 1 minute. ENERGY SAVINGS: Works with CFLs and LED lamps. 654A ORDERING INFO CATALOG NO. UPC CODE 601A 16020 602A 16021 611A* 16022 652A 16026 654A 16025 RATINGS 125 VAC, 15A, 1875W General Purpose 125VAC, 15A, 1875W Resistive 125VAC, 10A, 1250W Tungsten 125VAC, 1⁄2HP 125VAC, 15A, 1875W General Purpose 125VAC, 15A, 1875W Resistive 125VAc, 650W Tungsten 125VAC, 1⁄3HP, TV-5 NO. OF OUTLETS ( ) TYPE OF PLUG DESCRIPTION 1 Grounded Mechanical Outdoor Timer, with18" cord 2 Grounded Mechanical Outdoor Timer, with18" cord 1 Wall Mountable Grounded Mechanical Outdoor Timer, with 24" cord 2 Grounded Photocell Outdoor Timer with 6.5" cord 2 Grounded Photocell Outdoor Timer with 6.5" cord VARIABLE TIMING SEGMENTS 15 minutes Multiple ON/OFFs 15 minutes Multiple ON/OFFs 15 minutes Multiple ON/OFFs Photo ON Dawn or timed OFF Photo ON Dawn or timed OFF *611A: 1⁄3HP PHOTOCELL: 611D and 631D have built-in photocell to always turn ON at dusk and OFF at dawn. Add a time OFF schedule 655D 655D Remote WIRELESS REMOTE: 655D receives ON/OFF signal up to 80 feet away. ORDERING INFO CATALOG NO. UPC CODE 611D 16018 621D 16056 631D 655D* RATINGS NO. OF OUTLETS ( ) TYPE OF PLUG 1 Grounded 2 Grounded 16027 125 VAC, 15A, 1875W General Purpose 125VAC, 15A, 1875W Resistive 125VAC, 1000W Tungsten 125VAC, 8A Ballast 125VAC, 1⁄2HP 2 Grounded 16042 125VAC, 5A, 625W Resistive 125VAC, 600W Tungsten 2 Grounded DESCRIPTION Wall Mountable Photocell & 7 Day Digital 2-in-1 Timer, with 24" cord Wall Mountable, 7 Day Digital Timer, with 18" cord Wall Mountable Photocell & 7 Day Digital 2-in-1 Timer, with 18" cord Remote control indoor/outdoor receiver VARIABLE TIMING SEGMENTS Photo ON Dawn or timed OFF Multiple ON/OFFs for each day of the week Photo ON Dawn or timed OFF Handheld remote ON/OFF * ETL listed for U.S. and Canada. NOTE: " " = Indicates outlet location. NOTE: " " = Indicates outlet location. PLUG-IN TIMERS TORK 121 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 122 800 SERIES NEW! OUTDOOR GENERAL PURPOSE 1875W MECHANICAL & DIGITAL STAKE TIMERS APPLICATIONS Landscape and Christmas lighting Other outdoor lighting Energy saving 803B 806B FEATURES REPEAT SCHEDULE: Mechanical timer 24 hours. Digital timer 7 day programming. 806D MECHANICAL TIMING: Multiple ON/OFFs, Manual ON/ TIMER switch. DIGITAL TIMING: Manual ON/TIMER switch. Multiple ON/OFF for each day of the week. PHOTOCELL: 806D has optional built-in photocell to always turn ON at dusk and OFF at dawn or 1 to 12 hours later. ENERGY SAVINGS: Works with CFLs and LED lamps. ORDERING INFO CATALOG NO. UPC CODE 803B 16057 806B 16037 806D 16038 RATINGS 125VAC, 15A, 1875W Resistive 125VAC, 10A, 1250W Tungsten 125VAC, 15A, 1875W Resistive NO. OF OUTLETS ( ) TYPE OF PLUG 3 Grounded 6 Grounded 6 Grounded DESCRIPTION VARIABLE TIMING SEGMENTS Mechanical Outdoor Stake Timer, with 2' cord Mechanical Outdoor Stake Timer, with 2' cord. 3 timed outlets and 3 untimed. 15 minutes Multiple ON/OFFs 15 minutes Multiple ON/OFFs Multiple ON/OFFs for each Digital Outdoor Stake Timer, with 6' cord. 3 day of the week or Photo timed outlets and 3 untimed. ON and Dawn or 1-12 hours OFF. NOTE: " " = Indicates outlet location. PLUG-IN TIMERS TORK 123 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 124 TORKALERT ™ MECHANICAL STROBE HORNS ALARM SOUNDS MULTI-TONE ELECTRONIC HORNS ALARM TONE BELL HI-LO CHIME SINGLE STROKE BELL HORN 3 BEEPS, PAUSE SIREN SLOW WHOOP 24VDC &115VAC APPLICATIONS APPLICATIONS TA880-N5 High performance for industrial signaling applications. Offers high sound output, low current draw and dependable operation. Strobes use xenon flashtube, ideal for maximum efficiency and reliability. TA5508H-G1 ORDERING INFO CATALOG NO. UPC CODE INPUT VOLTAGE INPUT CURRENT (AMPS) dB @10 FEET CANDELA TA880-N5 96015 120VAC 0.115 96 15 ALARM: Penetrating mechanical sound. TA5508H-G1 96071 24VDC .059 strobe only 15/75 WIRING: Low current draw. NOTE: TA880-N5 For outdoor use, unit must be mounted in a TA-WBBF outdoor backbox. See page 138 for ordering. TA5508H-G1 for indoor mounting only. FEATURES MOUNTING: 4" square surface mounting. TA875-1G1 For indoor and outdoor use. Superior sound penetration for various room conditions. Screw terminals accept #12AWG. MECHANICAL HORNS FEATURES OPERATING TEMPERATURE: TA-MTS: -31˚F to +150˚F (-35˚C to +66˚C). DIMENSIONS AND MOUNTING: TA-MTS: 41⁄18”H x 41⁄8”W x 317⁄32”D Can be mounted on celing or wall. TA875-1G1: 43⁄4”H x 43⁄4”W x 13⁄8”D 1 gang, 2 gang or 4" square backbox. TA875-1G1 24VDC HORN CURRENT (AMPS) TA-MTS ALARM TONE HORN BELL HORN 2 CODE 3 HORN CODE 3 TONE SLOW WHOOP SIREN HI-LO TYPICAL dB @10 FEET 0.020 0.025 0.028 0.026 0.023 0.023 0.040 0.040 91 96 93 93 97 97 95 96 TA-MTS 115VAC HORN AMPS @ 120VAC TYPICAL dB @10 FEET HIGH STANDARD HIGH STANDARD OUTPUT OUTPUT 0.050 0.041 0.050 0.050 0.042 0.050 0.045 0.042 0.042 0.039 0.040 0.042 0.040 0.042 0.041 0.039 85 82 85 82 79 85 85 82 82 75 79 75 75 82 82 79 ORDERING INFO CATALOG NO. UPC CODE INPUT VOLTAGE DESCRIPTION TA875-1G1 97641 20-31VDC, 24VDC Multi-tone Electric Horn TA-MTS 97674 115 VAC Multi-tone Electric Horn HEAVY DUTY BELLS 4", 6", 10" DIAMETERS AC VIBRATING BELLS ORDERING INFO APPLICATIONS CATALOG NO. Loud tone with typical decibel output of 103 dB. Low frequency resonation for strong penetration of noisy areas like boiler rooms, water pumping stations, elevators and air compressor rooms. UPC CODE INPUT VOLTAGE INPUT CURRENT (AMPS) APPLICATIONS SURFACE TYPE TA874-N5 96023 120VAC, 60Hz 0.070 TA874-N5R (Red) 97613 120VAC, 60Hz 0.070 TA875-G1 97687 24VDC 0.035 For indoor or outdoor applications. High sound output, durable and dependable performance. Ideal for schools and hopsitals. ORDERING INFO INPUT VOLTAGE CURRENT (AMPS) dB @ 10 FEET CATALOG NO. UPC CODE SHELL SIZE TA340-4G5 96001 4” 24VAC 0.320 81-90 Dawn Mist TA340-4N5 96002 4” 120VAC 0.065 81-90 Dawn Mist TA340-6G5 96003 6” 24VAC 0.320 81-95 Dawn Mist TA340-6N5 96004 6” 120VAC 0.065 81-95 Dawn Mist COLOR WITH WEATHERPROOF BACKBOX TA-WBBF UL LISTED FOR OUTDOOR USE FEATURES TA876-N5 INPUT VOLTAGE: Wide input voltage ratings for compatibility with unregulated power supplies. HOUSING: Steel, painted Dawn Mist. Resonant grill design for high sound output. WIRING: Screw terminals for convenient IN/OUT wiring. Low current draw for minimizing power supply and wiring cost. MOUNTING: To indoor box TA-BBSF or outdoor box TA-WBBF, see accessories page 13*. NOTE: Use TORK signal timers for 24 hour or 7 day scheduling, see page 85. 96026 120VAC, 60Hz 0.070 FEATURES TERMINAL SIZE: #12 - 22 AWG. TA340-10G5 96005 10” 24VAC 0.320 84-98 Dawn Mist WIRING: Screw terminals permit fast IN/OUT field wiring. TA434-4N5 98005 4" 120VAC 0.065 81-95 Red HOUSING: Steel gong and cast aluminum. See page 138 for dimensional drawings. TA434-6N5 97521 6” 120VAC 0.065 81-95 Red TA434-10N5 96522 10” 120VAC 0.065 84-98 Red NOTE: Use TORK signal timers for 24 hour or 7 day scheduling, see page 85. TORK ALERT ™ TORK 127 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 128 LIGHT DUTY AND GENERAL PURPOSE BELLS & BUZZER WEATHERPROOF MOTOR DRIVEN SIREN DIMENSIONS FRONT VIEW 8-1/4" Power wires 2 feet long APPLICATIONS APPLICATIONS Designed to operate on either bell ringing transformers or batteries. Non-adjustable sound. TA725 (2) 9/32" mounting holes Mount siren (hardware not included) 15-3/8" FRONT VIEW For industrial and outdoor use. Ideal for evacuation and warning systems. TA740 6-7/8" 7-1/2" dia. (2) nuts, loosen to adjust siren direction. 8-1/4" FEATURES ALARM: Bell ringing, non-adjustable sound. DIMENSIONS FOR TA725: 3" H x 21⁄2" W x 1" D. MOUNTING: Fully enclosed sturdy steel bases and covers. Base and cover snap together, no screws required. ORDERING INFO FEATURES CATALOG NO. UPC CODE SWITCH VAC VDC AMPS dB TA740 96228 21⁄2” Gong 8-16 3-6 1 76 @ 10' TA744 96230 4" Gong 8-16 3-6 1 78 @ 10' TA725 96226 Buzzer 8-16 3-6 1 88 @ 3' ORDERING INFO MOUNTING: Fully enclosed sturdy steel bases. Junction box & (2) wire nuts (not furnished) ORDERING INFO CATALOG NO. UPC CODE INPUT VOLTAGE dB @10 FEET AMPS VA TA315-1N5 96599 120VAC/DC 117 2.5 300 APPLICATIONS Powerful and loud, pleasant sounding push-button chimes. Ideal for homes, apartments and offices. ALARM: Chime. HOUSING: Red enamel paint over heavy gauge aluminum housing. Fully enclosed motor. 180° swivel and adjustable direction. Siren power wires (2) 9/32" mounting holes PULL-DOWN STATION APPLICATIONS INPUT: 16V, 10VA, 120VAC. 1/2" conduit (not furnished) 6-7/8" MANUAL FIRE ALARM CHIMES & CHIME KITS FEATURES Power wires 2 feet long INPUT VOLTAGE: 120AC & DC, 60Hz. ALARM: Loud, distinctive tone. Designed to be effective over standard horns or bells. 8-1/2" dia. 1/2" conduit connector CATALOG NO. UPC CODE TAC212WS 96064 TAC212WL 96054 TAC210W 96052 DESCRIPTION 16VAC Chime + Push Button clip for Stucco + 10VA Transformer 16VAC Chime + 2 Push-buttons + 10VA Transformer 16VAC Chime DIMENSIONS 73⁄16”L x 4”W x 2”D 71⁄4”L x 43⁄4”W x 21⁄2”D 71⁄4”L x 43⁄4”W x 21⁄2”D Designed for indoor use. Ideal for schools, hospitals, industrial plants, warehouses and retail stores. Key required to close and reset device. Meets requirements, BSA, MEA, CA and UL. FEATURES ALARM: Loud, distinctive tone. Designed to be compatible with any control panel to initiate local alarm signals, trip municipal fire alarm box and start fire pumps. ORDERING INFO CATALOG NO. UPC CODE SWITCH VOLTS AMPS TA270A 96521 SPST, NO 30V AC/DC 1 MOUNTING: Sturdy metal construction, mounts to a standard single gang electrical box. TORK ALERT ™ TORK 129 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 130 TELEPHONE RELAY TELEPHONE STROBE APPLICATIONS APPLICATIONS For single-line analog phone lines. Emits a high intesity flashing light when the telephone rings. Ideal for alerting the hearing impaired, high ambient noise environments and quiet zones. ADA compliant. This device activates appliances when a telephone ring voltage is detected. For indoor and outdoor use with horns, bells or strobes. Recommended use where ambient noise levels are high. FCC approved. ORDERING INFO FEATURES PLUG: RJ-11C connection. TA-B-KHD-120VAC, includes 120VAC power cord. RINGER PEAK EQUIVALENCE CANDLEPOWER CATALOG NO. UPC CODE INPUT TELEPHONE RING VOLTAGE POWER TA-B-KHD-120VAC 97101 45-130V, 20-30Hz 120VAC 0.4 50-130V, 20-30Hz Analog line ring voltage 1.5 TA-B-KHD-1000-PP 97102 ORDERING INFO FEATURES CATALOG NO. UPC CODE INPUT TELEPHONE RING VOLTAGE AC INPUT VOLTAGE RINGER EQUIVALENCE PEAK CANDLEPOWER 70,000 INPUT: Accepts RJ-11C phone plug. TA-B-8332 97100 39-150V/20-30Hz WIRING: Hard wire connections, for analog phone lines. Up to 115VDC-500MA 0.6 8,000 115VAC-5A, 230VAC-2A MOUNTING: Easily mounts to interior surfaces, for indoor use. MOUNTING: Weatherproof, indoor and outdoor, includes mounting bracket. TELEPHONE HORN WALL CLOCKS QUARTZ & ELECTRIC ORDERING INFO QUARTZ CLOCK APPLICATIONS APPLICATIONS High quality compact signaling device. For indoor use. Easily connects to phone systems and enables locations with moderate to high ambient noise to have a loud telephone alert. FCC approved. Each model meets United States Government Specifications. All Clocks provide second hand for accurate timing. ORDERING INFO FEATURES ALARM: Adjustable tone and volume. FEATURES CATALOG NO. UPC CODE INPUT TELEPHONE RING VOLTAGE dB @3 FEET RINGER EQUIVALENCE TA-B-KHS-1000-PP 97103 50-130V, 20-30Hz 90 0.8 PLUG: RJ-11C modular connection. MOUNTING: Grey enclosure. For indoor use, surface mountable. QUARTZ Accurate to one minute per year. Low power consumption for long battery life. Uses AA battery (not supplied). ELECTRIC 110VAC, 60 Hz synchronous motor. 66 inch line cord and plug. Does not require grounding. MOUNTING: Concealed mounting brackets allow for simple, neat placement on walls. CATALOG NO. UPC CODE TYPE SIZE FRAME COLOR TA1886 G 96156 QUARTZ 8” Grey TA1886 B 96155 QUARTZ 8” Brown TA1887 G 96159 QUARTZ 12” Grey TA1887 B 96157 QUARTZ 12” Brown TA1887 BK 96158 QUARTZ 12” Black ELECTRIC CLOCK CATALOG NO. UPC CODE TYPE SIZE FRAME COLOR TA1880 G 96152 ELECTRIC 8” Grey TA1880 B 96151 ELECTRIC 8” Brown TA1882 G 96154 ELECTRIC 12” Grey TA1882 B 96153 ELECTRIC 12” Brown TORK ALERT ™ TORK 131 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 132 PUSH-BUTTONS ILLUMINATED, NON-ILLUMINATED & WEATHERPROOF ELECTRIC DOOR OPENERS REMOTE CONTROL & CONTACT DEVICES DIMENSIONS TA1786B Only 1 3/8" (34mm) 2-3/8" DIA. 1-13/16" BETWEEN CL 2 13/32" (61mm) MOUNTING HOLES ON MODEL TA1786B and TA1786CB MODEL TA1786CB For unlocking or locking metal or wooden doors using low voltage wiring. For AC, use TA591 or TA592 transformer. MORTISE TYPE REMOTE OPENER Reversible for right or left hand door. Use with mortise entrance locks having a latch bolt with up to 1⁄2" width and throw. Dimensional drawings available on page 138. DEVICE CATALOG NO. UPC CODE VOLTS AMPS For outdoor use to activate low voltage bells, buzzers, horns or any other audible signal. Ideal for factory doors, receiving departments, small office buildings, limited access retail stores and private homes. BUTTON For activating a variety of signals, ideal for limiting space applications. Self-insulating and can be mounted in any direction. All units include companion magnet. Dimensions: 23⁄16”L x 1⁄2”W x 1⁄2”D UPC CODE DESCRIPTION TA60 96975 Circuit closed with magnet engaged TA61 96976 Make & break NO and NC TA62 96977 Circuit open with magnet engaged VOLTS 24VAC 12VDC TA09 96960 8-16VAC 3-6VDC .95-1.75 1.25-1.80 AMPS MAX. TA154 .5 96962 16VAC 3-6VDC BUTTON Signals automatically with the opening and closing of doors, windows and transoms. Operates from pressure in any direction. Non-tilt, non-jamming design. Fits 3⁄4" hole; no need to mortise. DEVICE CATALOG NO. UPC CODE DESCRIPTION TA44 96995 Normally closed Push to open TA45 96996 Normally open Push to close TA46 Momentary contact 96997 Push to make & break VOLTS AMPS MAX. CATALOG NO. Reversible for right or left hand door. Standard surface type used with lock latches with up to 5⁄8" width and throw. 6" wire leads. Dimensional drawings available on page 138. CATALOG NO. UPC CODE TA603L 2 ELECTRIC DOOR SWITCH TA152 96961 UPC CODE DESCRIPTION INPUT VOLTAGE TA1786B 96090 Without conduit backplate TA1786CB 96091 With conduit backplate Momentary Contacts 4 amps AC/DC @ 12V 4 amps AC, 2 amps DC @ 24V 2 amps AC 1 amp DC @48V NON-ILLUMINATED PUSH-BUTTONS, UP TO 24VAC COLOR 96035 Gold CATALOG NO. UPC CODE COLOR SIZE TA600 96041 Polished Brass 21⁄4” (diameter) TA603 96044 Polished Brass 13⁄4” (diameter) TA631 96088 White 23⁄4 x 7⁄8" TA635 96047 Ivory, black bar 23⁄4 x 7⁄8" TA666BK 96048 Black, ivory bar 23⁄4 x 23⁄4 TA602 96043 Polished Brass 13⁄8 x 51⁄4 ” TA601 96042 Sprayed Brass 2 x 29⁄16 ” 5⁄8" TA620* 96045 Chrome 5⁄8” (diameter) 5⁄8" TA620B* 96046 Brass 5⁄8” (diameter) SIZE 13⁄4" (diameter) VOLTS TA631L 12-24V AC/DC UPC CODE RIM TYPE REMOTE OPENER DEVICE CATALOG NO. .95-1.75 1.25-1.80 ILLUMINATED PUSH-BUTTONS, UP TO 16VAC DOOR/WINDOW CONTACTS, ROLLING BALL TYPE MODEL TA1786B WEATHERPROOF PUSH-BUTTONS / SOLID CAST BRASS MAGNETIC SWITCH CONTACTS CATALOG NO. 2 13/32" (61mm) APPLICATIONS APPLICATIONS DEVICE 1 3/16" (30mm) 96089 White 23⁄4 x 7⁄8" 8-16VAC, 3-6VDC DOOR TRIP SWITCH TA656B 96039 Gold TA215LB 96031 Brass TA620L* 96037 Chrome TA620LB* 96038 Brass 15⁄16 x 23⁄4” BUTTON For turning lights/signals on or off when doors are opened or closed. Ideal for closets, dark rooms, Signals automatically as door is openend. Commonly used on store doors to announce storage areas of walk-in refrigeration. Rust resistant steel case with 4 knockouts, antique brass plate. entrance of customers. Mounts on top of door frame. Solid cast brass. Size: 3 x 15⁄8“ Box dimensions: 11⁄4"W x 3 7⁄8"H x 2”D. Plate dimensions: 11⁄4”W DEVICE CATALOG NO. UPC CODE DESCRIPTION VOLTS AMPS MAX. TA502 96964 Light ON when door is open 125VAC 250VAC 6 3 DEVICE CATALOG NO. TA236 TA503 96965 Light OFF when door is open 125VAC 250VAC 6 3 UPC CODE 96963 VOLTS 12-24VAC AMPS MAX. 2 11⁄4 x 2” (diameter) (diameter) *Stainless steel plate to fit TA620 models: Order TA 147-1 TORK ALERT ™ TORK 133 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 134 WARNING LIGHTS INDUSTRIAL UNITS WARNING LIGHTS VEHICULAR UNITS ORDERING INFO APPLICATIONS COLOR LETTER TO REPLACE "*" Red Amber Clear Blue R A C B conduit mounting. Full selection of dome colors, see "Ordering Info". For outdoor use. All units must be mounted vertically with base at bottom. DESCRIPTION TA52*N5 – COMPACT ROTATING BEACON DEVICE 117VAC 117VAC TA53*E1 – ROTATING BEACON Light intensifying reflector rotates arounf a low current 25 watt bulb. Bayonet socket for easy lamp replacement. Ideal for restricted or dangerous areas. VOLTS AMPS 90 FPM Corrosion resistant/Outdoor use Glass filled polypropylene housing Acrylic dome TA47AN5 96161 Tamper resistant dome clamps Nominal current draw TA47AR5 96162 91⁄2"H x 81⁄2” diameter TA47RN5 96061 CATALOG UPC NO. CODE TA52RN5 96063 .9 TA52AN5 96163 240VAC, 60Hz TA52BN5 96263 DESCRIPTION VOLTS AMPS DEVICE CATALOG UPC NO. CODE TA53RE1 96083 80-90 FPM 360˚ rotation Dependable belt & turntable design 117VAC .21 Acrylic dome Nominal current draw 61⁄2”H x 55⁄8” diameter TA53AE1 96183 TA53AF1 96185 Solid state circuitry in a low profile design. No moving parts means less Maintenance! TA93-2AN5 97623 TA93-2CN5 96968 TA93-2BN5 97624 Single point shock-mounting. Ideal for use on security or service vehicles. DESCRIPTION VOLTS 90-100 FPM Dependable belt & turntable design 25 watt lamp Acrylic Dome Nominal current draw 71⁄2”H x 6” diameter 12VDC DEVICE CATALOG UPC NO. CODE DESCRIPTION VOLTS 75 FPM, 12 watt lamp 12VDC Quiet belt-drive motor. Teardrop design fits under windshields. Includes glare shield, velcro tape TA54RE1 96087 41⁄2”H x 71⁄2” diameter TA54AE1 96187 36VDC 24VDC TA371L*N5 – ROTATING SEALED TWIN BEAMS TA93-2*N5 – MIDI-STROBE TA93-2RN5 99622 R A TA54*E1 – PORTABLE, MAGNETIC, ROTATING BEACON Single point shock-mounting. Ideal for use on security or service vehicles. TA53AG1 96184 DEVICE Red Amber conduit mounting. Full selection of dome colors, see "Ordering Info". For outdoor use. All units must be mounted vertically with base at bottom. TA47*N5 / TA47*R5 – ALL PURPOSE 360° BEACON CATALOG UPC NO. CODE LETTER TO REPLACE "*" 1⁄2" Large parabolic reflector rotates around a 100 wall bulb. Long range beam. Use to indicate equipment malfunctions, security intrusion, etc. CATALOG UPC NO. CODE COLOR APPLICATIONS 1⁄2" DEVICE ORDERING INFO DESCRIPTION Heavy Duty, double sealed beam, revolving light with 30 watt lamps. Each 35,000 CP bulb provides long range visibility. VOLTS AMPS 70-80 FPM Solid state electronic circuitry High output 3-4 watt, 3.6 joules Vertically mounted flash tube 117VAC .04 Snap out socket base for 360˚ Fresnel dome optics Nominal current draw 6 1⁄2”H x 5 1⁄8” diameter DEVICE CATALOG UPC NO. CODE TA371LRN5 96500 DESCRIPTION TA131D*N5 / TA131D*U1 – DOUBLE FLASH SUPER STROBE VOLTS AMPS 80-90 FPM 117 VAC Lexan® dome Quiet belt drive motor Anodized aluminum housing with polished aluminum, non-tarnishing base Snap lock retaining ring for quick & economical changeout 91⁄2”H x 8 1⁄2” diameter .8 Ideal for industrial applications requiring extremely high visibility. One model covers all popular mounting methods: 1⁄2" pipe, surface, flange, electrical box. DEVICE CATALOG UPC NO. CODE TA131DRN5 96510 TA131DAN5 96610 TA131DRU1 96511 TA131DAU1 97611 TA94*N5 – ELECTRONIC STROBE DESCRIPTION VOLTS AMPS 120VAC 60 FPM, 7.5 JPF High intensity 85,000 peak CP Flashtube Rated at 7000-8000 hrs. Durable Lexan® housing 10.55”H x 71⁄4” diameter .2 TA879 – VEHICULAR BACKUP ALARM Solid state electronic unit. Helps to comply with OSHA and State regulations. Makes distinctive noise, ideal for extreme variations in background noise DEVICE CATALOG UPC NO. CODE TA879 96102 DESCRIPTION VOLTS 2 sound levels 97 or 87 dB +/- dB at 4ft Multi-voltage Water-resistant housing 12 to 48VDC 31.0VDC High intensity strobe tube with inner fluted lens for maximum brilliance. No moving parts makes it immune to shock and vibration. Ideal for security alert. DEVICE CATALOG UPC NO. CODE DESCRIPTION VOLTS AMPS 70-80 FPM Solid state electronic circuitry High output 3-4 watt, 3.6 joules Acrylic dome TA94AN5 97627 117VAC .04 Glass filled polypropylene housing Suitable for outdoor use TA94BN5 97628 91⁄2”H x 81⁄2” diameter TA94RN5 97626 NOTE: "FPM" = Flashes per minute "JPF" = Joules per flash For replacement parts and accessories, see page 138. TORK ALERT ™ TORK 135 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 136 ACCESSORIES, REPLACEMENT PARTS & DIMENSIONS POWER SUPPLY UNITS 24 VDC UNITS TA640 TA606 Red Amber Clear Blue Green White Units provide power to multiple signaling devices depending on requirements. TA606 Regulated and filtered 24VDC up to 600mA. Easy to use screw terminals, accepts #16-24AWG. No conduit is required for installation. RIPPLE OUTPUT CURRENT REGULATION VOLTAGE CATALOG NO. UPC CODE INPUT VOLTAGE OUTPUT VOLTAGE TA606 96109 117VAC 24VDC 600mA TA640 96110 115VAC 24VDC 4A +/-5% 10mVRMS TA640 Dual output unit, each providing 2 Amps fo current. If connected in parallel, will provide up to 4Amps. Circuit breaker provides input protection. TRANSFORMERS UNIT ORDERING INFO UPC CODE TYPE TA590 96104 Bell TA591 96105 Chime VOLTS-AMPS PRIMARY SECONDARY (VA) VOLTAGE VOLTAGE 5 10 120 120 10 16 Hz 60 60 TA592 96106 Tri-Volt 10-10-20 120 8-16-24 50/60 TA598 96602 Tri-Volt 20-30-30 120 8-16-24 60 TA599 TA1245Y-50 TA1245Y-75 96108 96166 96167 Heavy Duty Heavy Duty Heavy Duty 96971 Acrylic Dome – Amber TA-M1 96138 12VDC Motor TA53, TA54 TA-B1 96114 Small Drive Belts TA53, TA54 TA-B2 96115 Large Drive Belts TA371L TA-B3 96116 Drive Belts TA53, TA54 TA-L3 96129 12VDC Bulb TA53 TA-L4 96130 24VDC Bulb TA93-2 TA-L6-2 96982 110VAC Xenon Flash Tube TA52 TA-L8 96134 110VAC Bulb TA47 TA-L9 96135 110VAC Bulb TA-L10 96136 110VAC Xenon Flash Tube TA-L10-1 96981 110VAC Xenon Flash Tube 40 50VA 75VA 120 120/208/240 120/208/240 24 24 24 60 60 60 TA-L12 97625 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com WIRING DIAGRAMS 1/2" 2-7/8" 1-13/16" TA874 Series TA-BBSF 97694 TA874 Series TA-WBBF 97692 Backbox – 4" painted Dawn Mist Weatherproof Backbox – .5" KOs 4" painted Dawn Mist Semi-Flush plate – Dawn Mist 3" 3-1/2" TA-ADR 96111 Acrylic Dome – Red TA47, TA94 TA-ADA 96311 Acrylic Dome – Amber TA47, TA94 TA-ADB 96411 Acrylic Dome – Blue TA52, TA53 TA-D5B 96419 Acrylic Dome – Blue WIRE LEADS 11/16" 3/32" 1-3/8" TA-D6A 96320 Dome – Amber TA54 TA-D6C 96422 Dome – Clear TA93, TA94 TA-D7R 96121 Fresnal Dome – Red TA93, TA94 TA-D7A 96321 Fresnal Dome – Amber TA-D7B 96421 Fresnal Dome – Blue TA131D TA-D8R 96970 4-1/16" 15/16" 3/16" 7/16" HEAVY DUTY BELLS 6” 10" DIA. 10” 6" 4-1/16" 3-3/8" 3-3/8" 10" DIA. 4-1/16" 3-3/8" 3-3/8" 4-1/16" 3-3/8" 3-1/4" .173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES 3-3/8" 4-1/16" 3-3/8" .173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES 4 1/16” 3-3/8" 3-3/8" 3-1/4" 4-1/16" .173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES .173 DIA. CSK 80 ° TO 82° 6" 11/32" DIA. – 4 PLACES TO 4-1/16" 3-3/8" Acrylic Dome – Red .173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES 3-1/4" 3-3/8"4-1/16" 3-1/4" 3-1/4" 3-1/4" .173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES 4” 3-3/8" 10" DIA. 6" 4-1/16" 4-1/16" 3-3/8" 4-1/16" Fresnal Dome – Clear TA93, TA94 5/8" 27/32" 23/32" Dome – Red TA54 CL 1-9/16" No. 6 FLAT HEAD WOOD SCREW Semi-Flush plate – Red TA47, TA94 3/32" 7/16" CL TA154 1/4" 15/16" 7/32" 1/8" 5/8" 1-1/4" Replacement switcH 96621 1-1/4" 110VAC Bulb 4-1/16" TORK 137 NO. 8 FLAT HEAD WOOD SCREW TA503SW 96969 TA-D7C 1" CL TA503 TA93, TA94 5/8" 1-3/4" 5-7/8" Replacement switch 96120 1-9/16" 3-5/8" TA502SW 96966 TA-D6R 3/4" 5-3/8" TA502 TA54 3/8" 1-3/8" Backbox TA-BBSF, TA-WBBF TA-SFPFR 97697 11/32" 2-3/4" 3/32" TA502-BX 96967 97707 1/8" 1/16" TA09 TA502 TA-BBSF, TA-WBBF TA-SFPF 1/16" 9/16" DESCRIPTION 3-3/8" TORK ALERT ™ 11/16" No. 6 MOUNTING SCREWS (3) 1/2" CL TA-D8A TA94 APPLICATIONS CATALOG UPC NO. CODE WIRE LEADS CL 1-3/8" 2-1/8" < Full selection of dome colors. To designate color, place desired letter in place of " * " TA53 TA-94 CATALOG NO. 3-5/16" 1-3/16" TA131D TA371L Engineered to ensure long use on bells, buzzers and chimes. 9/16" TA152 ORDERING INFO ORDERING INFO FEATURES REMOTE CONTROL DOOR OPENERS 15/16" APPLICATIONS LETTER TO REPLACE "*" R A C B G W COLOR DIMENSIONS 4-1/16" 2-7/8" .173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES TORK 138 POOL&SPA CONTROLS PP PANEL SERIES POOL AND SPA PANELS WITH TIME SWTICHES APPLICATIONS Pumps Swimming pools Fountains Ponds LISTED POOL/SPA CONTROL PANEL 3NZM PP-100R-P4 ORDERING INFO PP-20R-2P4 CONTROL INPUT CONTROL #2 120VAC N/A Rated for 15A, 1⁄2HP @ 120VAC 53011 Mechanical 24 hour timer Digital 7 day timer 120VAC N/A Rated for 15A, 1⁄2HP @ 120VAC PP-20R 94015 N/A 120/240VAC N/A Panel only. Add controls from page 147 and 148. PP-20R-P1 53000 P1101-M 120VAC N/A PP-20R-P4 53001 P1104-M 240VAC N/A DEVICE MOUNTING: Provision for mounting one or two devices in any combination accepts toggle, GFCI, X-10 and UPB type devices in, PP-100R and PP-125R enclosures. PP-20R-2P1 53002 P1101-2M 120VAC PP-20R-2P4 53003 P1104-2M 240 VAC Included with control #1 mechanism Included with control #1 mechanism PP-100R 94016 N/A 120/240VAC TRANSFORMER: Select panels include 120V input: 100 watt with output 12V/13V or 300 watt with output 12V/13V/14V. PP-100R-P4 53004 P1104-M 240VAC PP-100R-P4P1 53005 P1104-M 240VAC P1101-M 120VAC PP-100R-2P4 53006 P1104-M 240VAC P1104-M 240VAC PP-100R-P4P4FM 53009 P1104-M 240VAC P1104FM-M 240VAC PP-125R 94017 N/A 120/240VAC PP-125R-P4 53007 P1104-M 240VAC PP-125-2P4 53008 P1104-M 240VAC P1104-M 240VAC PP-125R-P4-100X 94018 P1104-M 240VAC PP-125R-P4-300X 94019 P1104-M 240VAC PP-10R-M-GFCI FEATURES COMBINATION PANEL: The PP panel series provides a flexible platform to create a custom pool and spa control at an off the shelf price. Start with a blank panel and addtimers, freeze controls, circuit breakers, switches and outlets for a custom installation. Or select a pre-assembled timer/panel available in many popular combinations. PP-10R: 15 amp timed GFCI protected outlet with additional GFCI outlet. PP-20R: 20 amp load center 120-240V, 1/2 circuit breaker base. PP-100R: 100 amp load center 120-240V, 5/10 circuit breaker base. PP-125R: 125 amp load center 120-240V, 8/16 circuit breaker base. CONTROLS: Freeze protection or mechanical and digital timers are all available with unique features not found elsewhere in the industry. Find specification details on pages 147 and 148. BREAKERS: Listed for Cutler Hammer (BR), GE (THQL), Murray/Siemens (MP) and Square D (HOM) (not included). REVERSIBLE DOOR: Easy-Hinge patented removable and reversible door. Change from left to right opening. Solves installation issues in the field. WHILE-IN-USE COMPARTMENT: Inside mounting for two devices with cord exit. COMPACT 2-IN-1: PP-20R-2P1 and PP-20R-2P4 includes two timers in a compact housing. Interlock switch allows second timer to turn ON only if first timer is in operation. ENCLOSURE: Metal NEMA 3R with lockable hasp. See page 153 for dimensions. NOTE: " " = Indicates freeze protection. POOL & SPA CONTROLS TORK 141 PP-125R-P4-100X PP-125R-P4 PP-20R-P4 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com CATALOG NO. UPC CODE PP-10R-M-GFCI 53010 PP-10R-E-GFCI CONTROL #1 CONTROL INPUT ADDITIONAL INFORMATION 120VAC Two timers design 50A panel 240VAC Two timers design 60A panel Panel only. Add controls from page 147 and 148. Add another control from page 147 and 148. Timer 2 includes Fireman Switch Panel only. Add controls from page 147 and 148. Add another control from page 147 and 148. Includes 100 watt Low Voltage Transformer Includes 300 watt Low Voltage Transformer TORK 142 PFP SERIES 1100 SERIES POOL FREEZE PROTECTION SWIMMING POOL TIME SWITCHES SPECIFICATIONS SAME ON/OFF TIMES EACH DAY SWIMMING POOL TIME SWITCHES INPUT VOLTAGE: 120 or 208-277VAC, 60Hz (varies by model). TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG. OPERATING TEMPERATURE: -40° to 165°F (-40° to +74°C). APPLICATIONS APPLICATIONS POWER CONSUMPTION: 3 watt max. Pool pumps Heaters Lighting Pumps Swimming pools Fountains Ponds ENCLOSURE: Lockable hasp. Type varies by model. See page 153 for dimensions and additional enclosure information. FEATURES SCHEDULING: Minimum ON setting is 20 minutes with a minimum OFF setting of 75 minutes. Dial accommodates up to 12 pairs of trippers. One pair included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF automatic operation then resumes. FEATURES FREEZE PROTECTION ONLY: Sensor turns on load when outdoor air temperature drops to user settable level between 33°F to 42°F. Moving water prevents costly freeze damage. TIMERS WITH FREEZE PROTECTION: Control loads with mechanical or digital timer with regular on and off schedule. Built-in temperature sensor forces load on if outdoor air temperature drops to user settable level between 33°F to 42°F. COMBINATION PANEL Combination of timers, freeze protection, breaker base, and device mountings. PP-20R: 20 amp load center 120-240V, 1⁄2 circuit breaker base. PP-100R: 100 amp load center 120-240V, 5⁄10 circuit breaker base. ORDERING INFO CATALOG NO. UPC CODE CONTROL CONTROL INPUT NOTES CATALOG NO. UPC CODE PFP2 94035 PFP2-M 240VAC Freeze protection only 1101 10011 PFP3 94036 PFP3-M 120/240 w/neutral Freeze protection only 1101-M-IAP 10052 PFP1102 94037 PFP1102-M 240VAC 1104 10014 PFP1103 94038 PFP1103-M 120/240 w/neutral 1104-N 10042 PFPEW1102 94039 PFPEW1102-M 240VAC 1104-O 10017 PFPEW1103 94040 PFPEW1103-M 120/240 w/neutral 1104-M-IAP 10051 PP-20R-F2 94033 PFP1102-M 240VAC 1101FM-N 10043 94034 PFP1102-M & P1104FM-M 240VAC Freeze protection with timer Freeze protection with timer Freeze protection with Digital timer Freeze protection with Digital timer Freeze protection with timer Timer 2 includes Fireman Switch 1104FM-N 10044 120/240VAC Thermostat accessory 1101FM-M 10043 1104FM-M 10044 1101D 10028 1104D 10029 1104DF 10032 PP-100R-F2F4FM PFPT 94028 BEAKERS: Listed for Cutler Hammer (BR), GE (THQL), Murray/Siemens (MP) and Square D (HOM) (not included). WHILE-IN-USE COMPARTMENT: Inside mounting for two devices with cord exit. Replacement Trippers DEVICE MOUNTING: Provision for mounting one or two devices in any combination accepts toggle, GFCI, X-10 and UPB type devices. POOL & SPA CONTROLS TORK 143 NOTE: " A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com CONTACT RATINGS ORDERING INFO " = Indicates Freeze Protection. Replacement Motor INPUT SUPPLY (VAC) 60Hz OUTPUT CONTACTS ENCLOSURE TYPE Metal Indoor NEMA 1 Mechanism and 120 SPST mounting plate Metal Indoor 208-277 DPST NEMA 1 ® Indoor/Outdoor Noryl 208-277 DPST NEMA 3R Metal Indoor/Outdoor 208-277 DPST NEMA 3 Mechanism and 240 DPST mounting plate Noryl® Indoor/Outdoor NEMA 120 SPST 3R with fireman switch ® Indoor/Outdoor NEMA Noryl 208-277 DPST 3R with fireman switch Mechanism with fireman 120 SPST switch Mechanism with fireman 208-277 DPST switch Two 1101 Metal Indoor/Outdoor 120 SPST each NEMA 3R Two 1104 Metal Indoor/Outdoor 208-277 DPST each NEMA 3R One 1104 Metal Indoor/Outdoor NEMA 208-277 One 1104FM 3R Order #P47 for a pair of ON/OFF trippers Order #PF48 for a pair of ON/OFF trippers for 1100FM series 120 SPST TYPE VOLTAGE CONTACT RATING 40A Resistive 120-277VAC single phase 120-277VAC single phase Tungsten 120VAC 40A Inductive 120, 277VAC single phase 20A Pilot Duty 120-277VAC 1000VA Motor 120VAC 240VAC 2HP 5HP General Purpose 40A #101 (120V) & #201 (208-277V) TORK 144 DW200B TIMER CONTACT RATINGS SPECIFICATIONS TWO SPEED PUMP CONTROL TIME SWITCH TYPE TIMING ACCURACY: Line Frequency. INPUT VOLTAGE: 120/208-240/277VAC, 50/60Hz. Two speed pumps SVRS device 30A 30A Ballast OPERATING TEMPERATURE: -40°F to 158°F (-40°C to +70°C). 120VAC 277VAC 30A 20A 10A 10A Tungsten 120-277VAC 15A 2A POWER CONSUMPTION: 5VA max. Pilot Duty 120-277VAC 720VA 720VA ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R is standard with lockable hasp. See page 153 for enclosure dimensions and accessories. Motor Load 120VAC 208-277VAC 1HP 2HP 1HP 2HP Resistive 28VDC 30A 30A CH 1 SPDT SPDT DWZ100B SERIES TWO CHANNEL: Two programmable contacts for independent control of pool equipment and SVR or coordinated control for two speed pumps. SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week at a minimum 1 minute apart. ORDERING INFO CATALOG NO. DW200B DW200B-0 UPC CODE 82190 82231 TIMER SUPPLY (VAC) 60Hz 120/208-240/277VAC 120/208-240/277VAC SPDT C TIMER SUPPLY NO. OF CHANNELS 2 2 DRY CONTACTS (UNPOWERED) DWZ100B SERIES TIMER SUPPLY N SPDT SPDT 120 208-240 277 120V N 120 208-240 277 208-240V 120V C NO NC TIMER SUPPLY N L N L 277V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE TIMER SUPPLY LOAD N CH 1 SPDT DW200B SERIES NO NC AC LINE INPUT SELECT277V PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE DAYLIGHT SAVING: Automatic adjustment (can be omitted) for year-round pools. DW200B SERIES LOAD 208-240V HOLIDAYS: 1 to 24 individual dates for preprogrammed longer run times for heavy use times. NC 24-277VAC WIRING DIAGRAMS FEATURES NO General Purpose TERMINAL RANGE: #12 - #16AWG. APPLICATIONS CONTACT RATING VOLTAGE 120 120V N 120 C 208-240 277 208-240 277 CH 2 SPDT C NO NC NO NC C 277V L 208-240V LOAD AC LINE INPUT N SELECT PROPER TERMINALS 277V AND APPLY ONLY ONE VOLTAGE C NO NC NO NC L 208-240V 120V CH 2 SPDT L LOAD L N LOAD N LOAD N AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE TWO SPEED PUMP WIRING MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. TWO SPEED PUMP WIRING CLOCK FORMAT: AM/PM or Military time POWER OUTAGE BACKUP: Permanent schedule retention when timer is powered down at the end of the season. Super capacitor provides 7 days of real time backup. POOL & SPA CONTROLS TORK 145 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com TORK 146 P1100 SERIES QUICK INSTALL/RELEASE LEVER: For easy installation and removal when installing into pool panels. SWIMMING POOL TIMERS, 24 HOUR ELECTROMECHANICAL CONTROL LOAD INDICATOR LAMP P1100 SERIES QUICK INSTALL/RELEASE LEVER: For easy installation and removal when installing into pool panels. SWIMMING POOL TIMERS, 7 DAY DIGITAL CONTROL LOAD INDICATOR LAMP LARGE LCD DISPLAY CONVENIENT EXTERNAL ROCKER SWITCH: 3 position switch: OFF/ON/AUTO. Use switch to turn OFF pump at the end of pool season. LARGE "MANUAL" BUTTON: 3 operating modes available: OFF/ON/AUTO. Using the OFF mode, the pool can be closed down without disrupting the time settings. REAL TIME SWITCH FACE: Easy to set and check time. POWER OUTAGE BACKUP: Battery retains time and schedule. CAPTIVE TRIPPERS: 15 minute intervals, no lost trippers. HEATER CONTACTS: FM suffix includes "Fireman Switch" to turn off pool heater 20-30 minutes before timer turns OFF. Contact rates SPST, 15A @120V. 7 DAY PROGRAMMING ONE MINUTE INTERVAL: Allows for the control of various electrical equipment on a 7 day schedule. 15 schedule weekly programs. THERMOSTAT: PFP models include built in Freeze Protection. No extra wiring. Thermostat turns on load at user settable level between 33°F and 42°F. Moving water prevents costly freeze damage. ACCESSORY CONTACT: PF models include extra contact to accept PFPT Freeze Protection Accessory. Thermostat turns ON load at user settable level between 33°F adn 42°F. Moving water prevents costly freeze damage. TIMER INTERLOCK: Makes one second timer dependant on operation of another timer. ORDERING INFO CATALOG NO. RESISTIVE/ UPC INPUT SUPPLY CODE (VAC) 60Hz CONTACTS INDUCTIVE RATINGS HP RATING PFP2-M 94026 240 DPST 40A 7.5HP @ 240V PFP3-M 94027 120/240 w/neutral DPST 40A 3 HP @ 120V 7.5HP @ 240V P1101-M 10056 120 DPST 40A 3 HP @ 120V P1101FM-M 10060 120 DPST 40A 3 HP @ 120V PF1101-M 94020 120 DPST 40A 3 HP @ 120V PF1101FM-M 94024 120 DPST 40A 3 HP @ 120V PFP1102-M 94022 240 DPST 40A 7.5HP @ 240V PFP1103-M 94023 120/240 w/neutral DPST 40A 3 HP @ 120V 7.5HP @ 240V P1104-M 10057 240 DPST 40A 7.5HP @ 240V P1104FM-M 10061 240 DPST 40A 7.5HP @ 240V PF1104-M 94021 240 DPST 40A 7.5HP @ 240V PF1104FM-M 94025 240 DPST 40A 7.5HP @ 240V P1101-2M 10058 120 DPST 40A 2HP @ 120V P1104-2M 10059 240 DPST 40A 5HP @ 240V POOL & SPA CONTROLS TORK 147 NOTES Thermostat only Thermostat only Fireman Switch Accepts PFPT thermostat input Fireman Switch & Accepts PFPT thermostat input Freeze Protection included Freeze Protection included Fireman Switch Accepts PFPT thermostat input Fireman Switch & Accepts PFPT thermostat input Replacement for PP-20R-2P1 Replacement for PP-20R-2P4 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com THERMOSTAT: PFPEW models include built in Freeze Protection. No extra wiring. Thermostat turns on load at user settable level between 33°F and 42°F. Moving water prevents costly freeze damage. ACCESSORY CONTACT: PFEW models include extra contact to accept PFPT Freeze Protection Accessory. Thermostat turns ON load at user settable level between 33°F and 42°F. Moving water prevents costly freeze damage. ORDERING INFO CATALOG NO. RESISTIVE/ UPC INPUT SUPPLY CODE (VAC) 60Hz CONTACTS INDUCTIVE RATINGS HP RATING PEW101-M 82432 120 DPST 40A 3 HP @ 120 PFEW101-M 94029 120 DPST 40A PFPEW1102-M 94031 240 DPST 40A PFPEW1103-M 94032 120/240 w/neutral DPST 40A Accepts PFPT thermostat input protection 7.5HP @ 240V Freeze included 3 HP @ 120V Freeze protection 7.5HP @ 240V included PEW104-M 82442 240 DPST 40A 7.5HP @ 240V PFEW104-M 94030 240 DPST 40A Accepts PFPT 7.5HP @ 240V thermostat input NOTES TIMER INTERLOCK: Makes one timer dependant on operation of another timer. 3 HP @ 120 NOTE: " " = Indicates Freeze Protection. WIRING DIAGRAMS POOL & SPA JUNCTION BOXES A B C APPLICATIONS For installation of underwater pool lights or low voltage connections. Solid brass with grounded post and 3 ground terminals for use with metallic or PVC conduit. NOTE: " " = Indicates Freeze Protection. ORDERING INFO CATALOG NO. UPC CODE NPF CONDUIT HUB PIPE INPUT A/B/C SIZE PB-50 94041 1⁄2" / 1⁄2" / 1⁄2" 1⁄2" PB-75 94042 3⁄4" / 3⁄4" / 3⁄4" .3⁄4" PB-100 94043 3⁄4" / 1"/ 3⁄4" 3⁄4" & 1" TORK 148 SR-500 & SR-500PS NEW! SAFETY VACUUM RELEASE SYSTEMS 2 1 Of all the protections you can put between your family and the risk of entrapment, the best protection is APPLICATIONS AT THE SOURCE. ® A Safety Vacuum Release System (SVRS) works by monitoring the vacuum on the suction side of the pool or spa pump. When a blockage occurs in the main drain or skimmer, a sudden rise in vacuum will cause the SR-500 and SR-500PS to shut down and activate an audible alarm. The pump will remain off with the alarm sounding until manually reset. Make Your Pool & Spa Safer, Update your LAYERS OF PROTECTION Door alarms on doors leading to the pool or spa area help to alert parents or staff to anyone entering the pool from the house or building. Commercial & Residential Swimming pools and spas Fountains Ponds Any pump size WARNING ALARM: Multiple audible alarm capabilities – allows for quicker alert to harmful situations. AUXILARY CONTACTS: Accessible extra dry contact – auxiliary equipment can be added. EQUIPMENT PROTECTION: Low vacuum sensing - (prevents cavitations or running the pump dry, eliminating costly equipment failure). SCHEDULING: Programmable 24 hour timer, or as stand-alone SVRS working in conjunction with existing pool controller. POOL & SPA CONTROLS TORK 149 Remote alarms linked to the Safety Vacuum Release System (SVRS) alert parents or attendants when the SVRS is activated, indicating that someone in the pool may need help. ORDERING INFO FEATURES PROTECTION: • Provides an important layer of protection, reducing entrapment risk. • Turns off pump in milliseconds upon detecting sudden vacuum change. • Vacuum monitored 128 times per second, rapid response and accurate readings. • Power monitored 50/60 times per second, insures continuous power detection. • Newest state-of-art NEC microprocessor technology-- guaranteed reliability and performance. OUTSIDE THE POOL AREA Keep children from accessing the pool or spa when unattended DOOR ALARMS 1 POWER OUTAGE BACKUP: Insures settings and reading will be saved, 30 minute rapid recharge. INPUT SUPPLY DRY CONTACTS (VAC) 60Hz (UNPOWERED) CATALOG NO. UPC CODE SR-500 95425 120/240 DPST SR-500PS 95426 120/240 DPST MAINTENANCE OVERRIDE: 30 minute maintenance override - (for pool or spa service). BUILT-IN DIAGNOSTICS: Displays error codes, prevents guessing during troubleshooting. EASY RETROFIT: Integrates with common existing timer box Trouble free installation, no pipes to cut or glue. COMPLIANCE: ASME/ANSI 112.19.17 as required by the International Building Codes (IBC) and the International residential Codes (IRC). Meets all current codes and standards for SVRSs on new and existing pools and spas. ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R with lockable hasp. See page 153 for dimensions and additional information. 2 Restrict access to a pool or spa by surrounding the area with fencing that is equipt with a self-closing, self-latching gate closure. Utilize gate latches that are adjustable, magnetically operated as well as key lockable. CONTACT RATINGS TYPE General Purpose Motor VOLTAGE 120VAC 240VAC 120VAC 240VAC FENCE & GATE 3 An emergency STOP button allows parents or attendants in the area to immediately and easily shut down the pump system in the event of entrapment. INSIDE THE POOL AREA Minimize the risk of entrapment injuries or drowning CONTACT RATING 20A 3HP EMERGENCY STOP 4 SVRS The SVRS automatically shuts down the vacuum pump when sensing a rise in vacuum pressure – in some cases, reacting to potential entrapment conditions in LESS THAN ONE SECOND! Audible alarms linked to the SVRS alert those nearby to a potential entrapment. SVRS should meet or exceed ASME/ANSI A112.19.17 standards in order to comply with IRC and IBC codes. 5 3 DRAIN COVERS Minimize potential entrapments or “Differential Hold Down Forces,” thereby minimizing the potential for a swimmer to be entrapped. 4 5 Anti-entrapment drain covers should meet or exceed ASME and ANSI A112.19.8 2007 and 2007 Federal Pool & Spa Safety Act and have a Certified Safe Flow Rating. Many compliant drain covers are easily retrofitted to existing drains. ALL ITEMS AVAILABLE FROM NSi/TORK! A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com More details available in our Safety Products catalog and Layers of Protection brochure, ask your sales representative for more information. ANTI-ENTRAPMENT DRAIN COVERS SELF-LATCHING GATE CLOSURES & SELF-CLOSING GATE HINGES NEW! NEW! 640-475XV TCA1-MK2 DS360M TCHD1ARP-MK2 AV20X20 & AV26X26 FEATURES DS360M DRAINSAFE • Designed for use with suction outlet sumps up to 8" in size, will retrofit smaller 5” sumps using additional knockouts. • Certified Safe flow of 123 GPM. • ASME/ANSI A112.19.8 2007 Standard Compliant. DS12X12P DRAINSAFE • Designed to retrofit Pentair style frames, and functions on dual drain as well as single suction outlets. • Certified Safe flow of 250 GPM @ 1.5 FPS. • ASME/ANSI A112.19.8 2007 Standard Compliant. DS12X12H DRAINSAFE • Designed to retrofit Hayward style frames, and functions on dual drain as well as single suction outlets. • Certified Safe flow of 250 GPM @ 1.5 FPS. • ASME/ANSI A112.19.8 2007 Standard Compliant. FEATURES DS12X12P DS12X12H ORDERING INFO CATALOG NO. UPC CODE DESCRIPTION SURFACE AREA (SQ.IN) RETROFIT FRAME DS360M 95431 Drainsafe Anti-Entrapment Type Suction Outlet Cover 27 N/A DS12X12P 95429 53 Pentair DS12X12H 95430 53 Hayward 640-475XV 95432 159.6 18 x 18 AV20X20 95433 AV26X26 95434 Drainsafe 12 x 12" Anti-Entrapment Type Suction Outlet Cover Drainsafe 12 x 12" Anti-Entrapment Type Suction Outlet Cover Waterway 18 x 18" Anti-Entrapment Drain Cover Eureka 20 x 20" Anti-Entrapment Drain Cover Eureka 26 x 26" Anti-Entrapment Drain Cover 640-475XV WATERWAY • Designed for single and multiple drain use, the 640-475XV works on dual drain as well as single suction outlets. • Minimizes “Differential Hold Down Forces” of dual drain systems. • Certified Safe flow rate of 540 GPM @ 1.09 FPS. 73.6 108.9 12 x 12 (9 x 9 minimum) 18 x 18 (12 x 12 minimum) MAGNA•LATCH GATE CLOSURES MagnaLatch quality latches are self-latching with permanent magnets which never lose power, for safer, child-resistant security for your swimming pool gate. The Top Pull model can be mounted so the release knob reaches the minimum code height, typically 54", on a shorter gate. It's adjustable for when the gate gets out of alignment. The Vertical Pull model is designed for gates and fences that are 60” or more in height. TRU•CLOSE GATE HINGES TruClose® hinges are designed so the residential homeowner can quickly and easily adjust tension to support a 375lbs gate load and self-closes up to a 55lb gate, for the ultimate safety around pools and other areas requiring self-closing gates. Hinges are rust-free and are self-lubricating. Regular duty and heavy duty models available. FENCE MATERIAL PACKAGING AVAILABLE CATALOG NO. UPC CODE DESCRIPTION MLTPS2BGA 95439 MagnaLatch Top Pull Gate Latch MLTPRP 95445 MLVPS2BGA 95440 MLVPRP 95444 MLS2RPAKA 95446 Round Post Adapter Kit Wholesale MLSPACER 95447 MagnaLatch Gap Spacer Retail Wholesale MagnaLatch Top Pull Gate Latch, 2" Gap Retail Spacer included Wholesale MagnaLatch Vertical Pull Gate Latch MagnaLatch Vertical Pull Gate Latch, 2" Retail Gap Spacer included REGULAR DUTY MODELS TCA1RP-MK2 98018 TruClose® Regular Range Gate Hinge Metal Retail TCA1-MK2 98026 TruClose® Regular Range Gate Hinge Metal Wholesale TCA3RP-MK2 98019 TruClose® Regular Range Gate Hinge Vinyl, Wood Retail TCA3-MK2 98027 TruClose® Regular Range Gate Hinge Vinyl, Wood Wholesale TCAMA2RND 98024 TruClose® Regular Range Gate Hinge, Round frames adjustable gap Wholesale HEAVY DUTY MODELS DS-MR DS-AA TORK 151 MLTPS2BGA POOL & SPA SAFETY ACCESSORIES AV20X20 & AV26X26 EUREKA • Eureka drain covers unique grating system is designed for new construction and retrofit, to add protection from entrapment. • ASME/ANSI A112.19.8 2007 Standard Compliant. • Certified Safe flow rate of 223 GPM (20x20), 495 GPM (26x26). POOL & SPA CONTROLS ORDERING INFO TCHD1ARP-MK2 98020 TruClose® Heavy Duty Metal Retail TCHD1AL2-MK2 98021 TruClose® Heavy Duty, with 2 legs Metal Wholesale TCHD2RP-MK2 98022 TruClose® Heavy Duty Vinyl, Wood Retail TCHD2L2-MK2 98023 TruClose® Heavy Duty, with 2 legs Vinyl, Wood Wholesale SAFETY ACCESSORIES SR-RA SR-ESB SR-RA 95437 Remote Alarm SR-ESB 95438 Emergency Stop Button DS-AA 95435 Drainsafe Masonry Anchor Kit - for DS360M DS-MR 95436 Drainsafe Mud Rings, Universal Fit ALL ITEMS AVAILABLE FROM NSi/TORK! A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com More details available in our Safety Products catalog and Layers of Protection brochure, ask your sales representative for more information. TORK 152 ENCLOSURES ENCLOSURES STANDARD FOR MODELS METAL INDOOR NEMA 1 ENCLOSURE #68229 STANDARD FOR MODELS METAL INDOOR/OUTDOOR NEMA 3 MODEL #9006 STANDARD FOR MODELS METAL INDOOR NEMA 1 ENCLOSURE #63016-1 MECHANISM & MOUNTING BRACKET #62153-1 MODELS 1101 7120 TZ220L-0 TZ300L-0 TZ220L TW220L Use Bracket #64039 1102 7122 TZ300L-0 T920L-0 TZ300L TW300L W100 W120 W220 3-5/8 " W222 3-1/16" 1103 8001 W300 T920L W200 1104 8004 W302 T930L W202 1101FM 8061 W300L TW222L 1104FM 8121 W302L TW302L 7100 8301 #62158 "E" DOOR 7102 8601 T920L-E 7200 8602 TW220L-E T930L-0 7202 TU40-Y 1101-7 EW201-Y TRP400 7220 1847AZL LDS-A 7222 8007 7200L 8007L 7202L 8007V 7120L 8150 1847A 8150U 1848A 8007U 1849A 8007VL 1847AZ 8008 1847AL 8008L STANDARD FOR MODELS 2-1/2" ELC72PC/120 ELC72PC/208-240 11-1/2" 12" W302 DLC400BP LDSH-A STANDARD FOR MODELS DLC400BP 12-1/4" T930L-E MECHANISM ONLY MECHANISM MECHANISM WITH BRACKET WITH BRACKET #62153-1 #64039 4" 1101NC DGLC100A-NC 1101-M-IAP 7200 1103NC DGLC200A-NC 1104-M-IAP 7202 1104NC 1102 7120 8001-NC 1103 7122 METAL INDOOR NEMA 1 ENCLOSURE #70100 DG SERIES W200 W222L E101PB 1103-N W202 1847AW E Series W120 TU40 7-5/8" 1847AWL DTU40 EW Series 11-7/8" W220 DG Series DZS Series TERMINAL BLOCK MECHANISM ONLY GROUND 4-9/16 " SCREW MECHANISM & BRACKET CLEARANCE HOLE FOR GROUND SCREW 4-9/16 " MODELS 5441 6-5/8 " 5-1/16" 4-9/16 " 7-5/8" BRACKET 4-9/16 " MECHANISM ONLY 4-9/16 " 3-5/8 " TERMINAL BLOCK MECHANISM & BRACKET EWZ101-MB 2-3/32 " E, EWZ, EH SERIES EWZ103-MB 11-1/2" BRACKET SMC-3D 4-9/16MECHANISM " 3-5/8 " & BRACKET 6-5/8 " EWZ201-MB 6-5/8 " MECHANISM & BRACKET 3-3/8" MECHANISM ONLY EWZ120-MB 8-5/16" 3-1/16 " 2-1/2" 1-15/16 " 14-1/8" 12-3/4" 3-1/2" TERMINAL BLOCK MECHANISM & BRACKET DG SERIES WIRING COMPARTMENT 10-1/8" WITH MOUNTING BRACKET #64039 STINGL 3/4" or 1" KO 7-5/8" 6-5/8 " 3-5/8 " 1/2" or 3/4" KO 3-1/16" Note: Indoor Enclosure Only 11-1/2" TERMINAL BLOCK TERMINAL BLOCK 9000PC 3-1/16" 1-15/16 " DZS, DTS, DZM, DW, DWZ SERIES 3-1/4" STANDARD FOR MODELS W400A 1101D 1101DF W402A 1114D 1114DF W400AL 1104D 1104DF METAL DUPLEX INDOOR/OUTDOOR NEMA 3 MODEL #9004L 4-9/16 " 4-9/16 " 6-5/8 " EW103B-C EW120B-C TERMINAL BLOCK 3-1/16 " DZM, DW, DWZ BRACKET SERIES 6-5/8 " TERMINAL BLOCK 1-15/16 " MECHANISM & BRACKET DZS, DTS, MECHANISM ONLY PLASTIC INDOOR/OUTDOOR NEMA 3R WITH CLEAR WINDOW MODELS 4-9/16 " TERMINAL BLOCK 1-15/16 " MECHANISM & BRACKET 8-5/16" STANDARD FOR MODELS SMC-3D 3-1/16 " MECHANISM & BRACKET E, EWZ, 3-3/8" EH SERIES MECHANISM ONLY LC200M MODELS TERMINAL BLOCK 4-17/32 " 1102-M 1103-M 1104-M SMC-3D 8001-LC/WB DTWH40 8601 8121 8602 8061 5-1/2" 3.4000" EJWT E500T MECHANISM & BRACKET 3-13/32 " E501T 7 1/2” 7 1/ ” 2 1-13/16 " 9-3/8" 7-1/2" PP-20RPP-20R PP-20R-P1 PP-20R-P1 PP20R-P4 PP20R-P4 PP-20R-2P1 PP-20R-2P1 PP-20R-2P4 PP-20R-2P4 MECHANISMS/BRACKETS 5-37/64 " 3-1/16 " STANDARD FOR MODELS STANDARD FOR MODELS 1101-O 1104-O 7302, L, Z, ZL 8001U-0 1102-0 7200-O 1103-0 7202-O 8007-0 POOL PANEL SERIES 4" MECHANISM ONLY METAL INDOOR/OUTDOOR NEMA 3 MODEL 9000B – SUFFIX "O" LC200M MOUNTING WITH BRACKET MODELS 4-11/16" MECHANISM WITH BRACKET LC200M LC200M MECHANISM & BRACKET 4-17/32 " 3-9/32 " LDS LDSH MECHANISM & BRACKET LC200M 3-13/32 " LDS SERIES MOUNTING WITH BRACKET MODELS 3.4000" MECHANISM & BRACKET LDS 1-13/16 " 2-1/8 " 4-17/32 " LDSH 3-9/32 " 3.4000" LDS LDSH MECHANISM & BRACKET 3-13/32 " 13 3/8” 13 3/ ” 8 PP-100R PP-100R PP-100R-P4 PP-100R-P4 PP-100R-P1P4 PP-100R-P1P4 PP-100R-2P4 PP-100R-2P4 PP-100R-P4P4FM PP-100R-P4P4FM 17 3/4” 17 3/ ” 4 SHOWN WITH SNAP TRACK 3-3/8" 4 5/8” 4 5/ ” 8 4 1/4” 4 1/ ” 4 4" 7 1/2” 7300, L, Z, ZL 8001-0 8007U-0 4-11/16" 11” 3-3/4" MECHANISM & BRACKET 8301 3-1/16" 11” E502T #64039/62153-1/65447 5-13/16 " TERMINAL BLOCK EWJT & E500T SERIES ENCLOSURE SR-500PS 3-1/2" 4-9/16" 1-15/16 " 7000 Series 1847A, Z 1848A 3-9/32 " STINGL SVRS ENCLOSURE WITH MOUNTING BRACKET #62153-1 2-1/8 " 1101-M MECHANISM & BRACKET LDS LDSH MECHANISM & BRACKET MECHANISM & MOUNTING BRACKET #65446 6-5/8 " 4" MODELS SR-500 BRACKET 6-5/8 " TERMINAL BLOCK 3-1/16 " ADAPTER MECHANISM & BRACKET PLATE 4-9/16 " MECHANISM ONLY 5-1/16" NEMA 1 ENCLOSUREE, EWZ, EH SERIES METAL INDOOR/OUTDOOR NEMA 3 MODEL 9000A – SUFFIX "0" ELC712 1/2" or 3/4" KO 3/4" or 1" KO 2-3/32 " 6-5/8 " ELC78 4-3/16" 8-3/4" 1/4" MOUNTING HOLE W222 METAL INDOOR NEMA 1 ENCLOSURE FOR W400 SERIES ELC78 & ELC712 ENCLOSURE 5401 ENCLOSURE BRACKET 4-11/16" DWZ Series 4" 12" 3-1/16 " 1-15/16 " EWZ SERIES MECHANISM ONLY EWZ Series DZM Series STANDARD FOR MODELS TERMINAL BLOCK 9000P 1102-N SMC-3D EW Series PLASTIC INDOOR/OUTDOOR NEMA 3R #9000P MODELS 7120Z, ZL DW Series E Series 7102 10" 5441 and 5440 REMOTE CONTACTORS 7202Z, ZL DTS Series 7100 6-5/8 " 1104-N 18" 6-5/8 " 3-3/8" W220L BRACKET 3-5/8 " 4" 70100 W100 8001-N 4-9/16 " 12" DWZ SERIES 1101-N 8001U-N MECHANISM & BRACKET 2-3/32 " ELC74 ENCLOSURE ELC74 9/32" MOUNTING HOLES TRP800 6-5/8 " DZS, DTS, 7200Z, ZL 7122Z, ZL 4-9/16 " 4" 12" TRP800 TRP 800 (GROUP OF 8) 9/32" MOUNTING HOLES IAP BRACKET MECHANISM ONLY DG SERIES INTERMATIC ADAPTER PLATE EWZ SeriesDZM, DW, STANDARD FOR MODELS 10" TRP800 NORYL® & LEXAN® INDOOR/OUTDOOR NEMA 3R MODEL #9000NC 14-1/4" NORYL® INDOOR/OUTDOOR NEMA 3R MODEL #9000N ELC72PC/277 18" STANDARD FOR MODELS DLC400BP 9/32" MOUNTING HOLES ELC71PC/277 EW130B-Y EW120B-Y METAL INDOOR NEMA 1 ENCLOSURE #63100 ELC71 & ELC72 SERIES ENCLOSURE ELC71PC/120 ELC71PC/208-240 3-1/2" TRP 400 (GROUP OF 4) STANDARD FOR MODELS TRP 800 (GROUP OF 8) 9/32" MOUNTING HOLES TRP402 7-5/8" Use Bracket #62153-1 W300 TRP400 TRP 400 (GROUP OF 4) PP-20R PP-20R-P1 PP20R-P4 PP-20R-2P1 PP-20R-2P4 7 1/2” PP-20R PP-20R-P1 PP20R-P4 PP-20R-2P1 PP-20R-2P4 1-13/16 " 11” 13 3/8” 13 3/8” 6 1/8” 6 1/ ” 8 12 3/4” 12 3/ ” 4 11” PP-100R PP-100R PP-100R-P4 PP-100R-P4 PP-100R-P1P4 PP-100R-P1P4 PP-100R-2P4 PP-100R-2P4 PP-100R-P4P4FM PP-100R-P4P4FM PP-125R PP-125R PP-125R-P4 PP-125R-P4 PP-125R-2P4 PP-125R-2P4 PP-125R-P4-100X PP-125R-P4-100X PP-125R-P4-300X PP-125R-P4-300X 17 3/ ” 17 3/ ” 4 4 PP-10R-M-GFCI PP-10R-M-GFCI PP-10R-E-GRCI PP-10R-E-GRCI 20 3/4” 20 3/ ” 4 9 3/4” 9 3/ ” 4 2-1/8 " DZS100BP-0 DZS200BP-0 DZS200BP DW200B-0 DZM200BP-0 5-13/16 " 5-37/64 " 5-13/16 " 5-37/64 " 5401 4 1/4” SHOWN WITH SNAP TRACK 4 5/8” 4 1/4” 4 5/8” 4 5/8” 4 5/ ” 8 4 1/2” 4 1/ ” 2 SHOWN WITH SNAP TRACK 12 3/4” 12 3/4” PP-125R PP-125R 6 1/8” 6 1/8” TORK 153 PP-10R-M-GFCI PP-10R-M-GFCI TORK 154 ALPHANUMERIC INDEX ALPHANUMERIC INDEX 1101 . . . . . . . . . . . . . . . . . . . . . . . . . 31, 144 2104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 652A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 8001U-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C512HH . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZS100BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65 1101-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 2107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 654A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 8004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C515M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZS200BP . . . . . . . . . . . . . . . . . . . . . . . . . . 65 1101D . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 2115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 655D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 8007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C530M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZS200BP-12 . . . . . . . . . . . . . . . . . . . . . . . 65 1101FM-M . . . . . . . . . . . . . . . . . . . . . . . . 144 2116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 701A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 8007L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C560M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZS200BP-24 . . . . . . . . . . . . . . . . . . . . . . . 65 1101FM-N . . . . . . . . . . . . . . . . . . . . . . . . . 144 2117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 701AA . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 8007-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C560MH . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZS200BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65 1101-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 2223 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 711A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 8007U . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D1060LA . . . . . . . . . . . . . . . . . . . . . . . . . . 104 DZS400BP . . . . . . . . . . . . . . . . . . . . . . . . . 65 1101-M-IAP . . . . . . . . . . . . . . . . . . . . 31, 144 2224 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 7100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 8007U-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D1060M . . . . . . . . . . . . . . . . . . . . . . . . . . 104 DZS400BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65 1101-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 2421 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 7102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 8007V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D1060MW . . . . . . . . . . . . . . . . . . . . . . . . . 104 E101B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 1101-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 7120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 8007VL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D212H . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 E101PB . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 1101-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 3002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 7120L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 8008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D212HA . . . . . . . . . . . . . . . . . . . . . . . . . . 104 E103B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 1102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 3006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 7120Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 8008L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D212HW . . . . . . . . . . . . . . . . . . . . . . . . . . 104 E120B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 1102-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 3010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 7120ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 8061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 DG100A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 E201B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 1102-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 401A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 7122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 8121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 DG100A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 E500T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 1102-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 402A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 7122ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 8301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 DG180A . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 E501T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 1103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 403A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 7200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 8601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 DG200A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 E502T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 1103-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 405A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 7200L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 90058-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 DG280A . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 EJWT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 1103-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 422A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 7200-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A502H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DG280A-24 . . . . . . . . . . . . . . . . . . . . . . . . . 85 ELC712 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 1103-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 454D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 7200Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A502HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGLC100A-NC . . . . . . . . . . . . . . . . . . . . . . . 79 ELC71PC/120 . . . . . . . . . . . . . . . . . . . . . . . 73 1103-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 455D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 7200ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A502HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGLC200A-NC . . . . . . . . . . . . . . . . . . . . . . . 79 ELC71PC/208-240 . . . . . . . . . . . . . . . . . . . 73 1104 . . . . . . . . . . . . . . . . . . . . . . . . . 31, 144 457Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 7202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A506H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGM100A . . . . . . . . . . . . . . . . . . . . . . . . . . 63 ELC71PC/277 . . . . . . . . . . . . . . . . . . . . . . . 73 1104D . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 460D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 7202L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A506HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGM100A-Y . . . . . . . . . . . . . . . . . . . . . . . . 63 ELC72PC/120 . . . . . . . . . . . . . . . . . . . . . . . 73 1104DF . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 5001M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7202-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A506HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGS100A . . . . . . . . . . . . . . . . . . . . . . . . . . 85 ELC72PC/208-240 . . . . . . . . . . . . . . . . . . . 73 1104FM-M . . . . . . . . . . . . . . . . . . . . . . . . 144 5004M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7202Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A512H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGS100A-12 . . . . . . . . . . . . . . . . . . . . . . . . 85 ELC72PC/277 . . . . . . . . . . . . . . . . . . . . . . . 73 1104FM-N . . . . . . . . . . . . . . . . . . . . . . . . . 144 5007M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7202ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A512HH . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGS100A-24 . . . . . . . . . . . . . . . . . . . . . . . . 85 ELC74 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 1104-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5008M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A512HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGU100A-Y . . . . . . . . . . . . . . . . . . . . . . . . . 79 ELC78 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 1104-M-IAP . . . . . . . . . . . . . . . . . . . . 31, 144 5021M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7220L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A512HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGUM100A . . . . . . . . . . . . . . . . . . . . . . . . . 79 ELS-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 1104-N . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 5024M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7222 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A515M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGUM100A-Y . . . . . . . . . . . . . . . . . . . . . . . 79 EPC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 1104-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5026M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7222L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A515MA . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DIN100B . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 EPC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 1104-O . . . . . . . . . . . . . . . . . . . . . . . . 31, 144 5231 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 7300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A515MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DIN200B . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 EPC-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 1847A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5237 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 7300L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A515MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105 DLC400BP . . . . . . . . . . . . . . . . . . . . . . . . . . 81 EPC-LC . . . . . . . . . . . . . . . . . . . . . . . . . . 73, 75 1847AL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 7300Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A515MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DS12X12H . . . . . . . . . . . . . . . . . . . . . . . . 151 1847AW . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5403 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 7300ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A530M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DS12X12P . . . . . . . . . . . . . . . . . . . . . . . . . 151 EW101B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 EW103B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 1847AWL . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5404 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 7302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A530MA . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DS360M . . . . . . . . . . . . . . . . . . . . . . . . . . 151 EW103B-C . . . . . . . . . . . . . . . . . . . . . . . . . . 59 1847AZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5404-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 7302L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A530MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DS-AA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 EW103B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59 1847AZL . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 7302Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A530MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105 DS-MR . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 EW120B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 1848A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5441 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 7302ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A530MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DTS100B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 EW120B-C . . . . . . . . . . . . . . . . . . . . . . . . . . 59 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 5500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 73866 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 A560M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DTS200B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 EW120B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59 2000-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 803B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 A560MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DTS400B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 EW201B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 2000-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 5500-OC . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 5737TM . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 806B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 A560MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105 DTU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 EW201B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59 2001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5737TZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 806D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 A560MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 EWZ101 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 2002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 601A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 8001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 AV20X20 . . . . . . . . . . . . . . . . . . . . . . . . . 151 DW200B . . . . . . . . . . . . . . . . . . . . . . . . . . 145 EWZ101-MB . . . . . . . . . . . . . . . . . . . . . . . . 61 2005A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 602A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 8001-LC/WB . . . . . . . . . . . . . . . . . . . . . . . . 37 AV26X26 . . . . . . . . . . . . . . . . . . . . . . . . . . 151 DW200B-O . . . . . . . . . . . . . . . . . . . . . . . . 145 EWZ103 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 2007A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 611A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 8001-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C412H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 EWZ103-MB . . . . . . . . . . . . . . . . . . . . . . . . 61 2008A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 611D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 8001-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C460M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DWZ100B . . . . . . . . . . . . . . . . . . . . . . . . . . 69 EWZ120 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 2021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 621D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 8001-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C502H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZM200BP . . . . . . . . . . . . . . . . . . . . . . . . . 71 EWZ120-MB . . . . . . . . . . . . . . . . . . . . . . . . 61 2022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 631D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 8001U . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C506H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZM200BP-O . . . . . . . . . . . . . . . . . . . . . . . 71 EWZ201 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 2101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 640-475XV . . . . . . . . . . . . . . . . . . . . . . . . 151 8001U-N . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C512H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZS100BP . . . . . . . . . . . . . . . . . . . . . . . . . . 65 EWZ201-MB . . . . . . . . . . . . . . . . . . . . . . . . 61 TORK 155 TORK 156 ALPHANUMERIC INDEX ALPHANUMERIC INDEX HPS30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 PFP2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 T920L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TA503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA93-2RN5 . . . . . . . . . . . . . . . . . . . . . . . . 135 TCHD1ARP-MK2 . . . . . . . . . . . . . . . . . . . . . 152 LC200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 PFP2-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147 T920L-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TA503SW . . . . . . . . . . . . . . . . . . . . . . . . . 138 TA94AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TCHD2L2-MK2 . . . . . . . . . . . . . . . . . . . . . . 152 LC200M . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 PFP3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 T920L-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TA52AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TA94BN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TCHD2RP-MK2 . . . . . . . . . . . . . . . . . . . . . . 152 LCS115M . . . . . . . . . . . . . . . . . . . . . . . 75, 112 PFP3-M . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 T930L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TA52BN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TA94RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TRP-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 LDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 PFPEW1102 . . . . . . . . . . . . . . . . . . . . . . . 143 T930L-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TA52RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TA-ADA . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TRP-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 LDS-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 PFPEW1102-M . . . . . . . . . . . . . . . . . . . . . . 148 T930L-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TA53AE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TA-ADB . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TRP400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 LDSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 PFPEW1103 . . . . . . . . . . . . . . . . . . . . . . . 143 TA09 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA53AF1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TA-ADR . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TRP402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 LDSH-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 PFPEW1103-M . . . . . . . . . . . . . . . . . . . . . . 148 TA1245Y-50 . . . . . . . . . . . . . . . . . . . . . . . 137 TA53AG . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TA-B1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TRP800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 MLS2RPAKA . . . . . . . . . . . . . . . . . . . . . . . . 152 PFPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 TA1245Y-75 . . . . . . . . . . . . . . . . . . . . . . . 137 TA53RE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TA-B2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TRP802 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 MLSPACER . . . . . . . . . . . . . . . . . . . . . . . . . 152 PP-100R . . . . . . . . . . . . . . . . . . . . . . . . . . 141 TA131DAN5 . . . . . . . . . . . . . . . . . . . . . . . 136 TA54AE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TA-B3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TRP-U . . . . . . . . . . . . . . . . . . . . . 79, 112, 116 MLTPRP . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 PP-100R-2P4 . . . . . . . . . . . . . . . . . . . . . . 141 TA131DAU . . . . . . . . . . . . . . . . . . . . . . . . 136 TA54RE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TA-B-8332 . . . . . . . . . . . . . . . . . . . . . . . . . 132 TU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 MLTPS2BGA . . . . . . . . . . . . . . . . . . . . . . . . 152 PP-100R-F2F4FM . . . . . . . . . . . . . . . . . . . . 143 TA131DRN5 . . . . . . . . . . . . . . . . . . . . . . . 136 TA5508H-G1 . . . . . . . . . . . . . . . . . . . . . . . 127 TA-BBSF . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TU40-Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 MLVPRP . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 PP-100R-P4 . . . . . . . . . . . . . . . . . . . . . . . 141 TA131DRU1 . . . . . . . . . . . . . . . . . . . . . . . 136 TA590 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TA-B-KHD-1000-PP . . . . . . . . . . . . . . . . . . 131 TW-220L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 MLVPS2BGA . . . . . . . . . . . . . . . . . . . . . . . . 152 PP-100R-P4P1 . . . . . . . . . . . . . . . . . . . . . . 141 TA152 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA591 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TA-B-KHD-120VAC . . . . . . . . . . . . . . . . . . 131 TW-220L-E . . . . . . . . . . . . . . . . . . . . . . . . . 47 OSC10U . . . . . . . . . . . . . . . . . . . . . . . . . . 114 PP-100R-P4P4FM . . . . . . . . . . . . . . . . . . . 141 TA154 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA592 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TA-B-KHS-1000-PP . . . . . . . . . . . . . . . . . . 131 TW-222L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 OSC12PL . . . . . . . . . . . . . . . . . . . . . . . . . . 112 PP-10R-E-GFCI . . . . . . . . . . . . . . . . . . . . . . 141 TA1786B . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA598 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TAC210W . . . . . . . . . . . . . . . . . . . . . . . . . 129 TW-300L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 OSC15PLS . . . . . . . . . . . . . . . . . . . . . . . . . 111 PP-10R-M-GFCI . . . . . . . . . . . . . . . . . . . . . 141 TA1786CB . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA599 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TAC212WL . . . . . . . . . . . . . . . . . . . . . . . . 129 TW-302L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 OSC20U . . . . . . . . . . . . . . . . . . . . . . . . . . 114 PP-125-2P4 . . . . . . . . . . . . . . . . . . . . . . . 141 TA1880 B . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TAC212WS . . . . . . . . . . . . . . . . . . . . . . . . . 129 TZ-220L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 OSC5PL . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 PP-125R . . . . . . . . . . . . . . . . . . . . . . . . . . 141 TA1880 G . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D5B . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TZ220L-O . . . . . . . . . . . . . . . . . . . . . . . . . . 49 OSC5U . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 PP-125R-P4 . . . . . . . . . . . . . . . . . . . . . . . 141 TA1882 B . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D6A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TZ-222L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 OSCS20UP . . . . . . . . . . . . . . . . . . . . . . . . . 113 PP-125R-P4-100X . . . . . . . . . . . . . . . . . . . 141 TA1882 G . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA602 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D6C . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TZ-300L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 OSWS9P-120 . . . . . . . . . . . . . . . . . . . . . . . 110 PP-125R-P4-300X . . . . . . . . . . . . . . . . . . . 141 TA1886 B . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA603L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D6R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TZ-300L-O . . . . . . . . . . . . . . . . . . . . . . . . . . 49 OSWS9P-277 . . . . . . . . . . . . . . . . . . . . . . . 110 PP-20R . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 TA1886 G . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA606 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TA-D7A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TZ-302L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 OSWS9PD . . . . . . . . . . . . . . . . . . . . . . . . . 110 PP-20R-2P1 . . . . . . . . . . . . . . . . . . . . . . . 141 TA1887 B . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA61 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA-D7B . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 USB-MMP . . . . . . . . . . . . . . . . . . . . . . . . . . 65 OSWS9PDM . . . . . . . . . . . . . . . . . . . . . . . . 110 PP-20R-2P4 . . . . . . . . . . . . . . . . . . . . . . . 141 TA1887 BK . . . . . . . . . . . . . . . . . . . . . . . . 132 TA62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA-D7C . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 P1101-2M . . . . . . . . . . . . . . . . . . . . . . . . . 147 PP-20R-F2 . . . . . . . . . . . . . . . . . . . . . . . . . 143 TA1887 G . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA620 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D7R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 P1101FM-M . . . . . . . . . . . . . . . . . . . . . . . 147 PP-20R-P1 . . . . . . . . . . . . . . . . . . . . . . . . 141 TA215LB . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA620B . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D8A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 P1101-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147 PP-20R-P4 . . . . . . . . . . . . . . . . . . . . . . . . 141 TA236 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA620L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D8R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 P1104-2M . . . . . . . . . . . . . . . . . . . . . . . . . 147 SMC3D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 TA270A . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 TA620LB . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-L10 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 P1104FM-M . . . . . . . . . . . . . . . . . . . . . . . 147 SR-500 . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 TA315-1N5 . . . . . . . . . . . . . . . . . . . . . . . . 130 TA631L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-L10-1 . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W220L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 P1104FM-M 240VAC . . . . . . . . . . . . . . . . . 143 SR-500PS . . . . . . . . . . . . . . . . . . . . . . . . . 149 TA340-10G5 . . . . . . . . . . . . . . . . . . . . . . . 128 TA635 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-L12 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 P1104-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147 SR-ESB . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 TA340-4G5 . . . . . . . . . . . . . . . . . . . . . . . . 128 TA640 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TA-L3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W222 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 W222L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 PB-100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 SR-RA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 TA340-4N5 . . . . . . . . . . . . . . . . . . . . . . . . 128 TA656B . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-L4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 PB-50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 SS13B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 TA340-6G5 . . . . . . . . . . . . . . . . . . . . . . . . 128 TA666BK . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-L6-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W300L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 PB-75 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 SS13F . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 TA340-6N5 . . . . . . . . . . . . . . . . . . . . . . . . 128 TA725 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 TA-L8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W300-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 PEW101-M . . . . . . . . . . . . . . . . . . . . . . . . 148 SS20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 TA371LRN5 . . . . . . . . . . . . . . . . . . . . . . . . 135 TA740 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 TA-L9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 PEW104-M . . . . . . . . . . . . . . . . . . . . . . . . 148 SS20F . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 TA434-10N5 . . . . . . . . . . . . . . . . . . . . . . . 128 TA744 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 TA-M1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W302L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 PF1101FM-M . . . . . . . . . . . . . . . . . . . . . . . 147 TA434-6N5 . . . . . . . . . . . . . . . . . . . . . . . . 128 TA874-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127 TA-MTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 W400A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 PF1101-M . . . . . . . . . . . . . . . . . . . . . . . . . 147 SS700Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 SS700ZA . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 TA44 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA874-N5R . . . . . . . . . . . . . . . . . . . . . . . . 127 TA-SFPF . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W400AL . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 PF1104FM-M . . . . . . . . . . . . . . . . . . . . . . . 147 SS720A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 TA45 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA875-1G1 . . . . . . . . . . . . . . . . . . . . . . . . 128 TA-SFPFR . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W402A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 PF1104-M . . . . . . . . . . . . . . . . . . . . . . . . . 147 SS720AA . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 TA46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA875-G1 . . . . . . . . . . . . . . . . . . . . . . . . . 127 TA-WBBF . . . . . . . . . . . . . . . . . . . . . . . . . . 138 PFEW101-M . . . . . . . . . . . . . . . . . . . . . . . 148 SS721Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 TA47AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TA876-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127 TCA1-MK2 . . . . . . . . . . . . . . . . . . . . . . . . . 152 PFEW104-M . . . . . . . . . . . . . . . . . . . . . . . 148 SS721ZA . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 TA47AR5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TA879 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TCA1RP-MK2 . . . . . . . . . . . . . . . . . . . . . . . 152 PFP1102 . . . . . . . . . . . . . . . . . . . . . . . . . . 143 SSA100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 TA47RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TA880-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127 TCA3-MK2 . . . . . . . . . . . . . . . . . . . . . . . . . 152 PFP1102-M . . . . . . . . . . . . . . . . . . . . . . . . 147 SSA100R-24 . . . . . . . . . . . . . . . . . . . . . . . 102 TA502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA93-2AN5 . . . . . . . . . . . . . . . . . . . . . . . . 135 TCA3RP-MK2 . . . . . . . . . . . . . . . . . . . . . . . 152 PFP1103 . . . . . . . . . . . . . . . . . . . . . . . . . . 143 SSA200 . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 TA502-BX . . . . . . . . . . . . . . . . . . . . . . . . . 138 TA93-2BN5 . . . . . . . . . . . . . . . . . . . . . . . . 135 TCAMA2RND . . . . . . . . . . . . . . . . . . . . . . . 152 PFP1103-M . . . . . . . . . . . . . . . . . . . . . . . . 147 SSA200R-24 . . . . . . . . . . . . . . . . . . . . . . . 102 TA502SW . . . . . . . . . . . . . . . . . . . . . . . . . 138 TA93-2CN5 . . . . . . . . . . . . . . . . . . . . . . . . 135 TCHD1AL2-MK2 . . . . . . . . . . . . . . . . . . . . . 152 TORK 157 TORK 158 NOTES TERMS OF SALE TORK VENDOR NUMBER: 662381 1. Prices are F.O.B. our plant. 2. Prices do not include any sales tax. 3. Freight charges will be prepaid on all orders $100.00 and over shipping within continental USA using standard shipping methods and service. 4. Minimum order – $100.00. 5. Claims for shortage, erroneous charges or price corrections shall be deemed waived unless made in writing, delivered to NSi within 30 days of invoice. 6. Terms of payment – 2% 10th prox. net 25th following. 7. Warranties – We strive to produce the highest quality products on the market today. NSi guarantees all products to be free of defects in material and workmanship for a period of 90 days from date of sale. Any claims for defective material must be agreed to in writing by NSi. Defective material will be replaced on an F.O.B., our factory basis. NSi disclaims the implied warranty of fitness for a particular application. OTHER PRODUCTS AVAILABLE ADDRESS 9730 Northcross Center Court Huntersville, North Carolina 28078 USA PHONE office 800.321.5847 technical support 888.500.4598 FAX 800.841.5566 EMAIL nsi@nsiindustries.com WEB www.nsiindustries.com NSi can provide many other products for special applications which are not listed in this catalog. If you require an item which you do not find listed, please contact us. We would be pleased to provide a quotation upon receipt of a drawing or a sample. GUARANTEE It is our goal to provide extraordinary products and services on a daily basis. If our products or service do not meet with your satisfaction, please let us know immediately and we promise to make every reasonable effort to remedy the situation.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Page Count : 80 Create Date : 2017:08:23 05:39:18 Creator : PDFium Producer : PDFiumEXIF Metadata provided by EXIF.tools