Tork Catalog
User Manual: Tork-Catalog
Open the PDF directly: View PDF
.
Page Count: 80
| Download | |
| Open PDF In Browser | View PDF |
PRODUCT CATALOG
2011
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
responsible
energy
A DIVISION OF
NSi INDUSTRIES, LLC
NSi Industries LLC
About Us
Since 1975, NSi’s strength is in the unique products that we bring to
the market, combined with our exceptional ability to provide quality
TORK® brand products manufactured in the company’s Mount Vernon
facility. TORK® is NSi Industries largest brand, covering the categories of
Electromechanical and Digital Time Switches, Signaling and Alert Devices,
Pool and Spa Controls, Residential Timers, Photocontrols and Occupancy
Sensors.
For over 85 years, TORK brand recognition and reputation for quality and
design make it the most specified brand in the industry. The TORK brand
has a rich history beginning in the 1920s when the company introduced
the first electromechanical time switch to the marketplace. Currently, TORK’s
time switches maintain energy efficiency through lighting control in such
high profile places as the Empire State Building, Washington DC Parks and
Recreation, The Triborough Bridge, The Met Life Building and many more
institutions across the country. As the most specified brand of time switches in the
industry, TORK enjoys the hearty respect of engineers and project planners
across all channels of distribution.
In the past several years, we’ve introduced a number of TORK time
switches, in-wall and plug-in timers to meet increasingly specific needs in
the marketplace. We’ve also added a line of installer-friendly pool and
spa panels and time switches, and are proud to offer essential pool safety
products that meet and exceed federal requirements for safe pools. We
look forward to designing and engineering more of our Responsible Energy
products, helping save money and the environment through responsible and
minimal use of energy.
TABLE OF CONTENTS
TABLE OF CONTENTS
ENERGY CODE REFERENCE GUIDE . . . . . . . . . . . . . 7
PHOTOCONTROLS
QUICK LOOK FEATURES & COMMON FEATURES . . .
2100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2110 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2001 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2020 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5000M SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . .
2005A, 2007A, 2008A SERIES . . . . . . . . . . . . . . .
5200 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5400 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5737 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PHOTOCONTROL ACCESSORIES . . . . . . . . . . . . . . .
11
13
14
15
16
17
18
19
20
21
22
23
24
ELECTROMECHANICAL
QUICK LOOK FEATURES & COMMON FEATURES . . . 27
TU40 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
1100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
7000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7000Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
8000 SERIES, DUTY CYCLE . . . . . . . . . . . . . . . . . . 37
8000 SERIES, REPEATING VARIABLE CYCLE . . . . . . 39
WH2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
1800 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
W SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
T900 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
TZ SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
ELECTROMECHANICAL ENCLOSURES
& DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . 153
DIGITAL
QUICK LOOK FEATURES . . . . . . . . . . . . . . . . . . . . 53
DTU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
E SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
E-PB SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
EW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
EWZ SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
DG100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
DZS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
DTS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
DW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
DZM SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
ELC SERIES, 1 & 2 ZONE . . . . . . . . . . . . . . . . . . . 73
ELC SERIES, 4, 8 &12 ZONE . . . . . . . . . . . . . . . . . 75
LC200 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
DGU SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
DGLC SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
DLC400BP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
LD SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
DGS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
EJWT & E500T SERIES . . . . . . . . . . . . . . . . . . . . . 87
DIN SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
SMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
5401 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
HPS STARTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
TRP SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
DIGITAL ENCLOSURES & DIMENSIONS . . . . . . . . . 153
IN-WALL TIMERS
QUICK LOOK FEATURES . . . . . . . . . . . . . . . . . . . . 97
SS720A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 98
SS700Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 99
SS721Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 99
701A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
711A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
SSA SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
SS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
C SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
OCCUPANCY SENSORS
SENSOR TECHNOLOGY & PLACEMENT GUIDE . . . . 109
OSWS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 110
OSC15PLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
OSC12PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
OSC5PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
OSC20UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113
OSC SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
ELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
TRP-U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
PLUG-IN TIMERS
400A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . .
400D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . .
600A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . .
600D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . .
800 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . .
119
120
121
122
123
TORK ALERT
MECHANICAL STROBE HORNS . . . . . . . . . . . . . . .
MECHANICAL HORNS . . . . . . . . . . . . . . . . . . . . .
MULTI-TONE ELECTRONIC HORNS . . . . . . . . . . . .
HEAVY DUTY BELLS . . . . . . . . . . . . . . . . . . . . . .
BELLS & BUZZERS . . . . . . . . . . . . . . . . . . . . . . .
CHIMES & CHIME KITS . . . . . . . . . . . . . . . . . . . .
WEATHERPROOF MOTOR DRIVEN SIREN . . . . . . .
MANUAL FIRE ALARM . . . . . . . . . . . . . . . . . . . .
TELEPHONE STROBE . . . . . . . . . . . . . . . . . . . . . .
TELEPHONE HORN . . . . . . . . . . . . . . . . . . . . . . .
TELEPHONE RELAY . . . . . . . . . . . . . . . . . . . . . . .
WALL CLOCKS . . . . . . . . . . . . . . . . . . . . . . . . . .
ELECTRIC DOOR OPENERS . . . . . . . . . . . . . . . . .
PUSH-BUTTONS . . . . . . . . . . . . . . . . . . . . . . . . .
127
127
128
128
129
129
130
130
131
131
132
132
133
134
WARNING LIGHTS, INDUSTRIAL . . . . . . . . . . . . . 135
WARNING LIGHTS, VEHICULAR . . . . . . . . . . . . . . 136
POWER SUPPLY UNITS . . . . . . . . . . . . . . . . . . . . 137
TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . 137
ACCESSORIES/REPLACEMENT PARTS/DIMENSIONS 138
POOL & SPA
PP PANEL SERIES TIMERS . . . . . . . . . . . . . . . . . . 141
PFP PANEL SERIES TIMERS . . . . . . . . . . . . . . . . . 143
1100 SERIES TIMERS . . . . . . . . . . . . . . . . . . . . . 144
DW200B TIMER . . . . . . . . . . . . . . . . . . . . . . . . . 145
P1100 SERIES, 24 HOUR
ELECTROMECHANICAL MECHANISMS . . . . . . . . . . 147
P1100 SERIES, 7 DAY DIGITAL MECHANISMS . . . 148
JUNCTION BOXES . . . . . . . . . . . . . . . . . . . . . . . 148
STINGL SR-500 & SR-500PS, SVRS . . . . . . . . . . 149
LAYERS OF PROTECTION . . . . . . . . . . . . . . . . . . . 150
ANTI-ENTRAPMENT DRAIN COVERS . . . . . . . . . . . 151
MAGNALATCH SELF-LATCHING GATE CLOSURES . . 152
TRUCLOSE SELF-CLOSING GATE HINGES . . . . . . . .152
POOL&SPA SAFETY ACCESSORIES . . . . . . . . . . . . 152
ENCLOSURE DIMENSIONS . . . . . . . . . . . . . . . . . . 153
ALPHANUMERIC INDEX . . . . . . . . . . . . . . . . . . . 155
LA
N
AR
CH
ITE
CT
U
energy
saving
solutions
Each of these marked products have features that decrease
energy consumption and/or damage to the environment by one
or more of the following:
• Timed control, Photocontrol and/or Astronomic control of on
responsible
energy and off functions of lighting, fans, pumps and appliances
• Timed control of systems or multiple zones of lighting
• Photo or occupancy sensing control of lighting
• Supercapacitor backup, no batteries to replace or dispose.
• Helps meet CA Title 24, ASHRAE , IECC and other
standards for responsible building products
Small Space, Meeting Rooms, Restrooms, Storage Spaces: Occupancy Sensors, Interval Timers
The first zone includes small spaces such as offices, restrooms and storage areas places where people may not occupy the space continuously. Individual wall switch
replacement provides low cost installation, with occupancy sensors and interval timers
as the best solution. In the event that wall switches provide proper coverage for the
occupancy sensor, ceiling mounted options are available.
FIC
ES
energy
< Use the Quick Reference Energy
Code Guide for approved products.
responsible
energy
RE
CE
P
TIO
N
responsible
ZONE 1: SMALL SPACE
Responsible Energy
OF
< Responsible Energy is the mark
of TORK’s commitment to developing
and manufacturing energy saving,
environmentally friendly products.
FIC
ES
solutions
The first way to save energy begins with eliminating lighting when it isn't needed.
As with exterior lighting, an efficient design matches controls to the typical use of the
area.
OF
energy
saving
INTERIOR LIGHTING ZONES
RA
L&
ENERGY CODE
REFERENCE GUIDE
ZONE 2: LARGE SPACE
Small Space, Meeting Rooms, Restrooms, Storage Spaces: Time of Day with Override,
Occupancy Sensors
CALIFORNIA Title 24
LO
T
The first zone includes small spaces such as offices, restrooms and storage areas places where people may not occupy the space continuously. Individual wall switch
replacement provides low cost installation, with occupancy sensors and interval
timers as the best solution. In the event that wall switches provide proper coverage
for the occupancy sensor, ceiling mounted options are available.
ZONE 3: HARVESTING LIGHT
CE
ON
T
RO
EXTERIOR LIGHTING ZONES
EN
When ambient light levels drop at dusk, lighting is needed to provide safety and
security. BUT: Does all lighting need to be on all night long? The proper selection
of lighting controls is essential to ensuring that energy is only used when needed.
An efficient lighting control design creates zones of light levels that can be varied
by time at night.
Large of Small Spaces with Natural Light: Light Sensors, Light Sensors with Occupancy,
Astronomic Timers.
A third zone that uses daylighting control can be added to wither of the first two
zones. light sensors can shut off a portion of the lighting when windows or skylights
contribute sufficient natural light to the area. This "harvesting" of light is an
excellent, green way to conserve energy. (NOTE: Energy codes vary on the stated
maximum time, but shorter times can give more energy savings).
E
FIC
FIC
The first zone gives a minimum light level where security is the primary
need. Determine what lighting is necessary, such as building-mounted
wallpacks and a portion of the parking lot lighting. These should be on
from dusk to dawn, and are best controlled by a photosensor device.
OF
ST
RE
Security Lighting (all night): Photocontrols, Photosensor controls
OF
WA
R
EH
OU
SE
ZONE 1: MINIMUM LIGHT LEVEL / DUSK TO DAWN
E
RO
O
M
OF
RE
FIC
E
ST
RO
O
M
CO
NF
ER
FR
B
RO REA
OM K
OM
PA
R
KIN
G
ASHRAE 90.1
ZONE 2: HIGHER LIGHT LEVEL / DUSK TO TIME OFF
FRONT PARKING LOT
Safety & Architectural Lighting (not necessary all night): Photosensor/Timebased controls, Astronomic controls
The second zone provides a higher light level for safety, when people
are normally present. Maximum levels for the parking lot and all walkway lighting are needed. These lights are best controlled by a combination photosensor and time-based device to allow shut-off during
the night. The astronomic-calculated sunset/time control can also be
useful.
ZONE 3: ARCHITECTURAL / TIMED DUSK TO TIMED OFF
ARCHITECTURAL & LANDSCAPING
DOCKS & BACK
PARKING
LOT
CONFERENCE ROOM
RECEPTION
OFFICES
WAREHOUSE
OFFICES
RESTROOM
RESTROOM
Building Facade, Landscape and Signage: Astronomic controls
The third zone covers architectural lighting for building facade or landscape and signs. These are best controlled with an astronomic-calculated
sunset/time control.
TORK 7
OFFICE
OFFICE
OFFICE
BREAK
ROOM
TORK 8
PHOTOCONTROLS
FEATURES
QUICK LOOK
COMMON FEATURES
CHOICE OF PHOTOCELLS
Cadmium sulphide, epoxysealed cells. Available in 1⁄2”
and 1".
2100
SERIES
2110
SERIES
2000
SERIES
2001
SERIES
2020
SERIES
3000
SERIES
5000M
SERIES
2005A
SERIES
5200
SERIES
5737
SERIES
Page
13
14
15
16
17
18
19
20
21
23
Mounting
Conduit
Conduit
Conduit
Conduit
Conduit
Flush
Turn-Lock
Turn-Lock
Turn-Lock
Turn-Lock
Yes
Yes
Adjustable Swivel
Housing
Die Cast
Die Cast Zinc Aluminum
UV Stabilized UV Stabilized UV Stabilized
Plastic
Plastic
Plastic
UV Stabilized
Plastic
Lexan®
Lexan®
Lexan®
Lexan®
1 - 5 fc
1 - 5 fc
1 to 3 fc
1 to 3 fc
1.5 fc
5 fc
Turn ON Light Level
1 - 5 fc
1 - 5 fc
1 - 5 fc
1 - 5 fc
Adjustable light level
adjustment
Yes
Yes
Yes
Yes
Turn OFF Ratio
3:1
3:1
3:1
3:1
3:1
3:1
5:1
3:1
1.5:1
1.5:1
Time Delay ON
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Instant
Instant
Instant
Time Delay OFF
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Light Sensor
CdS
CdS
CdS
CdS
CdS
CdS
CdS
CdS
Silicon Diode
Silicon Diode
CFL Compatible
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Surge Protection
Photo Timer
TOUGH ENCLOSURES
All conduit and flush mounted
models utilize die-cast zinc,
die cast aluminum, or genuine
Lexan® materials. All turn-lock
models utilize high impact UV
stabilized polypropylene, ABS,
PBT or Lexan® materials.
CHOICE OF MOUNTING
ORIENTATION
Models are available in fixed
position or 180° swivel.
DEPENDABLE performance
Built-in time delay prevents false
switching due to light from passing
highway vehicles, lightning, etc.
Instant response is available in
turn-lock models (5200 Series).
TURN-LOCKS MEET ANSI C136.10
Yes
All models meet the current ANSI
requirements for locking-type
prongs and color coded voltage
designations. Locking prongs are
solid brass.
TORK® Photocontrols are
designed and manufactured with
components which adhere to
the highest industry standards.
Trained personnel and in-process
quality procedures ensure that
every unit meets our strictest
quality standards.
TORK 11
Color-Coded Dome
Grey
105-130VAC
Maroon 208-277VAC
Blue
105-285VAC
Yellow
480VAC
Green
347VAC
TORK 12
2100 SERIES
SPECIFICATIONS
SPECIFICATION GRADE
1/2" CONDUIT MOUNTING
DIE CAST ZINC
PHOTOCONTROL
ON/OFF: Turn ON is 1 to 5fc, Turn OFF is 3
to 15fc, without the slide in position. ON/OFF
adjustment is easily made by moving a slide
cover. No tools required.
APPLICATIONS
SPECIFICATIONS
SPECIFICATION GRADE
1/2" CONDUIT MOUNTING
DIE CAST ALUMINUM
PHOTOCONTROL
ON/OFF: Turn ON is 1 to 5fc, Turn OFF is 3
to 15fc, without the slide in position. ON/OFF
adjustment is easily made by moving a slide
cover. No tools required.
TIME DELAY: ON and OFF.
TIME DELAY: ON and OFF.
CELL: Cadmium sulphide, epoxy-coated, 1"
diameter.
CELL: Cadmium sulphide, epoxy-coated, 1⁄2”
diameter. Model 2117 is 1" cell.
CONTACTS: Remain closed between dusk and
dawn. (The unit fails in the ON position).
Parking lot lighting
Building perimeter lighting
Outdoor signage
2110 SERIES
LEAD WIRES: Three color coded, minimum
6” wire leads, #16AWG, rated for 105˚C.
APPLICATIONS
CONTACTS: Remain closed between dusk and
dawn (the unit fails in the ON position).
2117
Parking lot lighting
Building perimeter lighting
Outdoor signage
LEAD WIRES: Three color coded, minimum
6” wire leads, #16AWG, rated for 105˚C. (2117
#10AWG red and black).
2115 & 2116
POWER CONSUMPTION:
Averages under 1 watt.
POWER CONSUMPTION:
Averages under 1 watt.
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
FAIL MODE: ON.
FAIL MODE: ON.
WARRANTY: 5 years.
WARRANTY: 5 years.
CONTACT RATINGS
CONTACT RATINGS
RATING
CATALOG
SWITCH
WIRING
DIAGRAMS
NO.
TUNGSTEN
BALLAST
FEATURES
OPERATION: Delay of up to two minutes
to prevent false switching due to light from
passing vehicles, lightning, etc.
2101
SPST
2000W
1800VA
2104
SPST
2000W
1800VA
2107
SPST
2000W
1800W
2000 SERIES
HOUSING: Heavy Duty die cast zinc
housing and base. Gasketed for maximum
weather protection.
WIRING DIAGRAMS
VOLTAGE
50-60Hz
2101
60012
120VAC
2104
60013
208-277VAC
2107
60031
120/277VAC
73866
62020
Mounting Bracket
2100
SERIESDie case aluminum housing
HOUSING:
and base. Gasketed for weather protection.
2000 SERIES
SWITCH
2115
RATING
TUNGSTEN
BALLAST
SPST
2000W
1800VA
2116
SPST
3470-4620W
2080-2770VA
2117*
SPST
3000W
3000VA
2100 WIRING
SERIES
DIAGRAMS
ORDERING INFO
ORDERING INFO
UPC
CODE
OPERATION: Delay of up to two minutes
to prevent false switching due to light from
passing vehicles, lightning, etc.
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
CATALOG
NO.
FEATURES
CATALOG
NO.
CATALOG
NO.
UPC
CODE
VOLTAGE
50-60Hz
2115
60032
120VAC
2116
60033
208-277VAC
2117*
60037
120VAC
73866
62020
Mounting Bracket
*Not UL or CSA rated.
PHOTOCONTROLS
TORK 13
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 14
2000 SERIES
SPECIFICATIONS
1/2" CONDUIT MOUNTING
FIXED POSITION, LEXAN® HOUSING
WITH WEATHERPROOF SEALANT
PHOTOCONTROL
ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3
to 15fc, without the slide in position. ON/OFF
adjustment is easily made by moving a slide
cover. No tools required.
2001 SERIES
SPECIFICATIONS
1/2" CONDUIT MOUNTING
180° SWIVEL, LEXAN® HOUSING
PHOTOCONTROL
ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3
to 15fc, without the slide in position. ON/OFF
adjustment is easily made by moving a slide
cover. No tools required.
TIME DELAY: ON and OFF.
TIME DELAY: ON and OFF.
Cadmium sulphide, epoxy-coated, 1⁄2”
CELL:
diameter.
APPLICATIONS
CONTACTS: Remain closed between dusk and
dawn. (The unit fails in the ON position).
Flood lamp
Patio lamp
Decorative lighting
LEAD WIRES: Three color coded, minimum
6” wire leads, #16AWG, rated for 105˚C.
CELL: Cadmium sulphide, epoxy-coated, 1⁄2”
diameter.
APPLICATIONS
CONTACTS: Remain closed between dusk and
dawn. (The unit fails in the ON position).
Flood lamp
Patio lamp
Decorative lighting
LEAD WIRES: Three color coded, minimum
6” wire leads, #16AWG, rated for 105˚C.
POWER CONSUMPTION:
Averages under 1 watt.
POWER CONSUMPTION:
Averages under 1 watt.
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
FAIL MODE: ON.
FAIL MODE: ON.
WARRANTY: 5 years.
WARRANTY: 5 years.
CONTACT RATINGS
RATING
CATALOG
WIRING DIAGRAMS
SWITCH
NO.
TUNGSTEN
BALLAST
FEATURES
OPERATION: Delay up to two minutes to
prevent false switching due to light from
passing vehicles, lightning, etc.
2000
SPST
2000W
1800VA
2000-2
SPST
3470-4620W
2080-2770VA
2000-7*
SPST
2000W
1800VA
HOUSING: All Lexan® enclosures are
impact and vandal resistant. Translucent
Lexan® Dome prolongs cell life by further
screening out ultraviolet rays. Dome
and base are ultrasonically welded for
maximum strength.
WIRING DIAGRAMS
2000 SERIES
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
CONTACT RATINGS
FEATURES
OPERATION: Delay up to two minutes to
prevent false switching due to light from
passing vehicles, lightning, etc.
CATALOG
NO.
SWITCH
2001
2002
RATING
TUNGSTEN
BALLAST
SPST
2000W
1800VA
SPST
3470-4620W
2080-2770VA
HOUSING: All Lexan® enclosures are
impact and vandal resistant. Translucent
Lexan® Dome prolongs cell life by further
2100 SERIES
screening out ultraviolet rays. Dome
and base are ultrasonically welded for
maximum strength.
WIRING DIAGRAMS
Move Slide for Earlier
or Later Turn ON
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
ORDERING INFO
ORDERING INFO
CATALOG
NO.
UPC
CODE
VOLTAGE
50-60Hz
CATALOG
NO.
UPC
CODE
VOLTAGE
50-60Hz
2000
60017
120
2001
60015
120
2000-2
60018
208-277
2002
60016
208-277
2000-7*
62023
120/277
73866
62020
Mounting Bracket
73866
62020
Mounting Bracket
•
•
Red
Lamp
•
Move Slide for Earlier
or Later Turn ON
•240V
L2 •
L1
*Model 2000-7 has a cadmium sulphide, 1” epoxy cell. Also
UL listed and CSA certified.
Black Line
White Neutral
(Black) Line
(White)
(Red)
•
Lamp
For 277VAC:
L1 - Line
L2 - Neutral
PHOTOCONTROLS
TORK 15
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 16
2020 SERIES
SPECIFICATIONS
1/2" CONDUIT MOUNTING
180° SWIVEL, LEXAN® HOUSING
PHOTOCONTROL
ON/OFF: Turn ON is 1 to 5fc. Turn OFF is
3 to 15fc.
ON/OFF: Turn ON is 1 to 5fc. Turn OFF is
3 to 15fc.
CELL: Cadmium sulphide, epoxy-coated,
1⁄2” diameter.
CELL: Cadmium sulphide, epoxy-coated,
1⁄2” diameter.
POWER CONSUMPTION:
Averages under 1 watt.
Ideal for applications where it
is essential to aim the photocell
in an exact direction to sense
natural light but avoid artificial
light.
FLUSH MOUNTING
LEXAN® HOUSING
PHOTOCONTROL
TIME DELAY: ON and OFF.
LEAD WIRES: Three color coded,
minimum 6” wire leads, #16AWG, rated
for 105˚C.
Flood and patio lamps
Decorative lighting
SPECIFICATIONS
TIME DELAY: ON and OFF.
CONTACTS: Normally closed (the unit
fails in the ON position).
APPLICATIONS
3000 SERIES
CONTACTS: Normally closed (the unit
fails in the ON position).
APPLICATIONS
Flush Mounting
Model 3010
Pole lanterns
Lawn lighting
Walkways
LEAD WIRES: Three color coded,
minimum 6” wire leads, #16AWG, rated
for 105˚C.
POWER CONSUMPTION:
Averages under 1 watt.
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
FAIL MODE: ON.
FAIL MODE: ON.
WARRANTY: 5 years.
WARRANTY: 5 years.
CONTACT RATINGS
RATING
CATALOG
SWITCH
NO.
WIRING
DIAGRAMS
TUNGSTEN
CONTACT RATINGS
FEATURES
CATALOG
NO.
OPERATION: Delay up to two minutes to
prevent false switching due to light from
passing vehicles, lightning, etc.
SWITCH
UPC
CODE
VOLTAGE
50-60Hz
2021
60024
120
2022
60025
208-277
73866
62020
Mounting Bracket
BALLAST
SPST
2000W
1800VA
2022
SPST
3470-4620W
2080-2770VA
WIRING DIAGRAMS
120V
MODELS
ORDERING INFO
CATALOG
NO.
TUNGSTEN
2021
HOUSING: All Lexan® enclosures are
impact and vandal resistant, cover and base
are ultrasonically welded for maximum
strength.
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
FEATURES
RATING
Line
•Neutral
•
(Black)
(White)
(Red)
Lamp
L2
HOUSING & MOUNTING: Control housing
is weather-resistant molded Lexan® with
ultrasonically welded seams.
MODEL 3000: Flush mounting through .6875”
hole in post lantern or lighting fixture, 3⁄8” NPT,
stem 3⁄4” long. Gasket and nut supplied.
MODEL 3010: flush mounting into standard,
raintight junction box. Includes plate and gasket
to fit FS type outdoor junction box.
ENERGY SAVINGS: Works with screw base
CFLs and LED lamps.
•
3000
SPST
2000W
1800VA
3002
SPST
3470-4620W
2080-2770VA
3006*
SPST
1500W
1200VA
3010
SPST
2000W
1800VA
WIRING DIAGRAMS
120V
MODEL
LAMP
LINE BLK
120V
RED
NEUT. WHITE
ORDERING INFO
208-277V
MODELS
L1
OPERATION: Delay up to two minutes to
prevent false switching due to light from passing
vehicles, lightning, etc.
BALLAST
Line
•
(Black)
•
(White)
240V
Neutral
(Red)
•
For 277VAC
L1 - Line
L2 - Neutral
Lamp
CATALOG
NO.
UPC
CODE
VOLTAGE
50-60Hz
3000
60020
120
3002
60019
208-277
3006*
60026
347
3010
60021
120
208-277V
MODEL
For 277VAC:
L1 - Line
L2 - Neutral
LINE BLK
LAMP
RED
240V
WHITE
*CSA certified only.
PHOTOCONTROLS
TORK 17
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 18
5000M SERIES
SPECIFICATIONS
DELAYED RESPONSE UTILITY GRADE
MOV SURGE ARRESTOR
PHOTOCONTROL
ON/OFF: Turn-ON is 1 to 3 fc. Turn-OFF to Turn-ON
ratio is 5 max.
TIME DELAY: ON and OFF.
CELL: Cadmium sulphide photocell responds to the
light spectrum near to that of a human eye. Resists
effects of moisture and airborne contaminants.
APPLICATIONS
RELAY: Bi-metal provides positive snap action
switching, reducing bounce and prolonging contact life.
For use on streets, highways and
other luminaries equipped with
locking type receptacles, where
most stringent surge protection
is needed.
SURGE ARRESTOR: 380 joule MOV (metal oxide
varistor) exceeds ANSI and NEMA requirements.
LOCKING PRONGS: Solid brass for maximum
corrosion resistance and electrical conductivity.
TEMPERATURE RANGE:
-40˚ to +140˚F (-40˚ to +60˚C).
OPERATION: Delayed response prevents false
switching due to light from vehicles or lighting, etc.
STANDARDS: Meets ANSI C136.10 including color
designations. Also meets EEI NEMA standards.
ON/OFF: Turn-ON is 1 to 3 fc. Turn-OFF to TurnON is 3 average.
QUICK RESPONSE
TURN-LOCK MOUNTING
PHOTOCONTROL
TIME DELAY: Instant ON/3-5 seconds OFF.
CELL: Cadmium sulphide photocell responds to the
light spectrum near to that of a human eye. Resists
effects of moisture and airborne contaminants.
APPLICATIONS
CONTACTS: Solid brass prongs for maximum
corrosion resistance and electrical conductivity.
For use on streets, highways and
other luminaries equipped with
locking type receptacles, where
instant response is required.
SURGE ARRESTOR: 360 joules MOV exceeds
NEMA and ANSI requirements.
RELAY: Positive snap action switching, reducing
bounce and prolonging contact life.
Complies with ANSI C136.10 and
EEI NEMA standards.
TEMPERATURE RANGE:
-40˚ to +158˚F (-40˚ to +70˚C).
FAIL MODE: ON.
FAIL MODE: ON.
WARRANTY: 3 years.
WARRANTY: 3 years.
CATALOG
NO.
LIGHT SENSOR
5001M
RATING
TUNGSTEN
BALLAST
1"
1200W
1800VA
5004M
1"
3470-4620W
2080-2770VA
5007M
1⁄2"
2000W
3470-4620W
1800VA
2080-2770VA
HOUSING: Lexan® UV Stabilized, permanent color
with UV resistant clear acrylic window. Models 5026M
and 5008M with polypropylene dome. Provides high
impact, flammability resistance and electrically safe
operation.
5008M*
1"
1000W
1800VA
5021M
1⁄2"
2000W
1800VA
ENERGY SAVINGS: Works with screw base CFLs
and LED lamps.
5024M
1⁄2"
3470-4620W
2080-2770VA
5026M**
1⁄2"
1000W
1800VA
ORDERING INFO
CATALOG
NO.
UPC
CODE
VOLTAGE
50-60Hz
COLOR
5001M
61012
105-130
Grey
5004M
61013
208-277
Maroon
5007M
61014
105-130/208-285
Blue
5008M*
61017
480
Yellow
5021M
61015
105-130
Grey
5024M
61016
208-277
Maroon
61045
SPECIFICATIONS
CONTACT RATINGS
FEATURES
5026M**
2005A, 2007A
& 2008A
347
WIRING DIAGRAMS
2"
2 3/16"
Green
*Not UL listed or CSA certified.
**CSA certified only.
Receptacle Surface
2 3/16"
FEATURES
STANDARDS: Meets ANSI C136.10
including color designations. Also meets
EEI NEMA standards.
CONTACT RATINGS
HOUSING: Polypropylene, UV
Stabilized, permanent color with UV
resistant clear acrylic window. Provides
high impact, flammability resistance and
electrically safe operation.
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
RATING
CATALOG
NO.
TUNGSTEN
BALLAST
2005A
1000W
1800VA
2007A
1000W
1800VA
2008A*
1000W
1800VA
WIRING DIAGRAMS
ORDERING INFO
CATALOG
NO.
UPC
CODE
VOLTAGE
50-60Hz
COLOR
2005A
62012
105-130
Grey
2007A
62013
105-285
Blue
2008A*
62014
400-550
Yellow
2"
2 3/16"
Receptacle Surface
3 3/16"
*Not UL or CSA listed.
N
L1
Line
(Black)
N
Load (Red)
Neutral
(White)
Load
105 to 285 volt
single phase grounded
supplies and loads
L1
Line
(Black)
Load (Red)
Neutral
(White)
Load
105 to 285 volt
single phase grounded
supplies and loads
PHOTOCONTROLS
TORK 19
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 20
5200 SERIES
5400 SERIES
SPECIFICATIONS
UTILITY GRADE ELECTRONIC
WITH FAIL ON MODE
PHOTOCONTROL
SPECIFICATIONS
6000 WATT CONTACTORS
WITH TURN-LOCK
PHOTOCONTROL
ON/OFF: Turn ON is 1.5 foot candle +/- 0.2 OFF/ON
ratio is 1.5:1 average*.
RECEPTACLE: 3-prong turn-lock meets the
requirements of EEI NEMA.
POWER CONSUMPTION: Maximum 3 watts
during daylight.
TIME DELAY: Instant ON/3-5 second OFF*.
CELL: Silicon photosensor assures drift-free operation,
turning on and off at the same light level consistently
throughout the life of the unit.
APPLICATIONS
APPLICATIONS
CONTACTS: DC relay has positive snap action switching,
reducing bounce and prolonging contact life. Fail ON for
safety.
For use where the extreme
accuracy and reliability of
an electronic photocontrol is
required and in the event of
failure, light should stay ON for
safety reasons.
CONTACT RATINGS
For street lighting. Controls all
lighting loads in excess of the
capacity of the photoelectric
control contacts.
SURGE ARRESTOR: 920 joule MOV (metal oxide
varistor) exceeds ANSI and NEMA requirements.
LOCKING PRONGS: Solid brass for maximum corrosion
resistance and electrical conductivity.
POWER CONSUMPTION: 1.0 watt average @ 120V.
TEMPERATURE RANGE:
-40˚ to +158˚F (-40˚ to +70˚C).
CATALOG
NO.
SWITCH
CONTACT RATING
PER POLE
5403
DPST
3000W
5404
DPST
3000W
5404-3
DPST
3000W
5420
SPDT
3000W
FAIL MODE: ON.
WIRING DIAGRAMS
WARRANTY: 5 years.
*Consult factory for other ratios and time delays.
120 VOLT CIRCUIT
MODEL
WHT
5403
WHT
LOAD
STANDARDS: Meets ANSI C136.10
including color designations. Also meets EEI
NEMA standards.
HOUSING: UV stabilized, ANSI colorcoded, high impact polypropylene dome.
Cross-linked polypropylene gasket. High
impact ABS base. High impact, UV stabilized
acrylic window.
CONTACT RATINGS
CATALOG
NO.
LIGHT SENSOR
5231
5237
TUNGSTEN
BALLAST
Silicon Photosensor
1000W
1800VA
Silicon Photosensor
1000W
1800VA
2"
ORDERING INFO
WHT
78885
105-130VAC
5237
78886
105-305VAC
Line
(Black)
Load (Red)
Neutral
(White)
Load
105-305 VAC
single phase grounded supplies and loads
3 1/8"
120V
N
120 VOLT CIRCUIT
MODEL
5420
105 to 285 volt
single phase grounded
supplies and loads
CAS
DIMENS
RED LOAD 1
BLUE LOAD 2
WHT
H 120V
CATALOG
NO.
UPC
CODE
PHOTOCONTROL
INCLUDED
VOLTAGE
50-60Hz
5403
60009
5021M
105-130VAC
5404
60010
120 VOLT CIRCUIT
MODEL
WHT
5403
5024M
5404-3
60011
5024M
5420
60014
5021M
BLK
LOAD 1 CLOSES AT DUSK, OPENS AT DAWN
LOAD 2 CLOSES AT DAWN, OPENS AT DUSK
277 VOLT CIRCUIT
MODEL
5404-3
208-240VAC
BLK RED
WHT
BLK RED
WHT
WHT
BLK RED
BLK RED
208 or 240 VOLT
CIRCUIT
MODEL 5404
277VAC
LOAD
WHT
LOAD
LOAD
105-130VAC
LOAD
LOAD
LOAD
LOAD
WHT
WHT
WHT
H
H
120V
N
120V
N
H
H 120V
277V
N
120V/240V 3-WIRE SYSTEM
H
H
277V/480V 4-WIRE SYSTEM
CASE
DIMENSIONS
WHT
RED
208V or 240V
208V/240V 4-WIRE SYSTEM
Add photoelectric control dimensions
2" high x 3" diameter
BLK
BLUE LOAD 2
N
Load
277V/48
BLK
RED LOAD 1
Neutral
(White)
277V
N
120V/240V 3-WIRE SYSTEM
WHT
RED
N
L1
Load (Red)
H
H 120V
120 VOLT CIRCUIT
MODEL
5420
Line
(Black)
LOAD
WHT
H
120V
N
120V 2-WIRE SYSTEM
120V 2-WIRE SYSTEM
N
LOAD
WHT
H
ORDERING INFO
L1
Receptacle Surface
VOLTAGE
50-60Hz
5231
N
LOAD
WHT
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
WIRING DIAGRAMS
2 3/16"
UPC
CODE
HOUSING: Outdoor NEMA Type 3R. Beige
enamel finish. Two 1⁄2”– 3⁄4” combination
KO in bottom.
RATING
ENERGY SAVINGS: Works with screw
base CFLs and LED lamps.
CATALOG
NO.
BLK RED
FEATURES
WHT
H 120V
BLK
4-1/2"
(114mm)
7-1/4"
(184mm)
FEATURES
BLK RED
3-13/32"
(87mm)
LOAD 1 CLOSES AT DUSK, OPENS AT DAWN
LOAD 2 CLOSES AT DAWN, OPENS AT DUSK
PHOTOCONTROLS
TORK 21
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 22
5737 SERIES
TORK 5737 T Z PHOTO-TIMER
®
SPECIFICATIONS
ON AT DUSK, OFF AT MIDNIGHT
ON EARLY MORNING,
OFF AT DAWN
PHOTO-TIMERS
ON/OFF: Turn ON at dusk is 5.0 foot candle +/- 0.5 OFF/
ON ratio is 1.5:1 average.
THE MOST FLEXIBLE PHOTO-TIMER FOR MAXIMUM
ENERGY SAVINGS AND ALL ON/OFF NEEDS!
TIME DELAY: Instant ON/3-5 seconds OFF.
CELL: Silicon photosensor
Midnight OFF: Allows user to adjust OFF time during the
night. OFF time can be set for up to two hours before (for
extra energy savings) or up to two hours after midnight.
Use to stagger groups of lights to go OFF at different times
during the night.
Early Morning ON (537TZ only): Allows user to set number
of hours after midnight (from 2-10 hours) that lights
should turn back ON.
APPLICATIONS
Offices
Restaurant signage
Billboards
Landscape and yard lighting
No programming is required, the microprocessor tracks dusk and dawn
times and automatically determines midnight, and corrects for Daylight
Savings Time. It even re-learns and resets itself after a power outage, so that
no maintenance is ever needed.
CONTACTS: DC Relay, normally closed. Provides chatter
free operation. Solid brass Prongs for maximum corrosion
resistance and electrical conductivity.
Ideal for situations when visible
traffic is reduced – lights ON at
dusk and OFF at 11pm or later,
then on again for early morning
illumination.
TEMPERATURE RANGE:
-40˚ to +158˚F (-40˚ to +70˚C).
FAIL MODE: ON.
WARRANTY: 3 years.
PHOTOCONTROL
ACCESSORIES
FEATURES
FOR TURN-LOCK CONTROLS
OPERATION: Microprocessor tracks the
dusk and dawn times with the seasons and
automatically determines midnight, NO
PROGRAMMING REQUIRED. Automatically
"re-learns" and resets after power outage,
eliminating costly maintenance. DST correction
built in.
CONTACT RATINGS
CATALOG
NO.
SWITCH
5737TZ
5737TM
TUNGSTEN
BALLAST
SPST
1000W
1800VA
SPST
1000W
1800VA
2"
ORDERING INFO
VOLTAGE
50-60Hz
5737TZ
62010
105-305VAC
62009
DEVICE
CATALOG
NO.
5500
5500-OC
2 3/16"
UPC
CODE
5500 replaces photocontrol to change light fixture to always ON. 5500-OC
replaces photocontrol to change light fixture to always OFF. Durable materials
and gasket provide longevity and weatherproof protection.
WIRING DIAGRAMS
ENERGY SAVINGS: Works with screw base
CFLs and LED lamps.
CATALOG
NO.
REPLACEMENT CAPS
RATING
HOUSING: UV stabilized, ANSI color-coded
polypropylene dome. UV stabilized, clear acrylic
window. ABS base. Cross-linked, polypropylene
gasket.
5737TM
DUSK
MIDNIGHTON
OFF
EARLY MO
RNING ON
DAWN OFF
The TORK Photo-timer Plus is the most flexible photocontrol ever,
operating like a photocontrol AND a time switch! Ideal for retrofit without
expensive rewiring. The unit turns the load ON at sunset and can be preset
to turn the load OFF up to two hours before or two hours after midnight.
It can also be set to turn the load back ON from two to ten hours after
midnight and OFF at dawn.
2"
Receptacle Surface
3 1/8"
N
Load (Red)
Load
61132
DEVICE
Shorting cap
480VAC max
1800 Tungsten
1800VA Ballast
Open cap
480VAC max
(Black housing)
CATALOG
NO.
UPC
CODE
DESCRIPTION
2223
61025
Receptacle with Neoprene
gasket
RECEPTACLE
RECEPTACLE
120-480V receptacle with color-coded #14 leads, mounting bracket and one
mounting screw.
DEVICE
120 or
277V
2 3/16"
Line
(Black)
105-305 VAC
single phase grounded supplies and loads
3 1/8"
61130
DESCRIPTION
L1
Neutral
(White)
Receptacle Surface
105-305VAC
N
UPC
CODE
RECEPTACLE
120-480V receptacle with color-coded #14 leads, neoprene gasket and two
mounting screws.
CATALOG
NO.
UPC
CODE
DESCRIPTION
2224
61026
Receptacle and mounting
bracket
120-480V receptacle with color-coded #14 leads, plastic housing, lock nut (with
1⁄2" NPT) and a mounting bracket.
DEVICE
CATALOG
NO.
UPC
CODE
DESCRIPTION
2421
61021
Receptacle with plastic
housing and bracket
L1
Line
(Black)
Load (Red)
Neutral
(White)
Load
105-305 VAC
single phase grounded supplies and loads
FOR 240V, N=L2, L1=L1
PHOTOCONTROLS
TORK 23
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 24
ELECTROMECHANICAL
TIME SWITCHES
FEATURES
QUICK LOOK
SERIES
PAGE
NO.
CLOCK
DIAL
MINIMUM
SETTINGS
(MINUTES)
ON
OFF
SKIP
A
DAY
MANUAL SUNRISE/
OVERRIDE SUNSET
COMMON FEATURES
EASY TO SET DIAL ASSEMBLY
Tork’s 24 hour dial assembly allows the user
to set the time switch more accurately, easily
moving it by hand in small increments. Dial
can provide up to 12 ON/OFFs per day with
cycles as short as 20 minutes. AM and PM
settings are easy to see by the light and dark
areas of the dial.
MAX ON
& OFF
EVENTS
PER DAY
RATINGS RESERVE
(AMPS) POWER
SWITCH TYPES
29
24 Hour
15
15
Permanent
48
SPST
DPST
1100
31
24 Hour
20
75
Yes
12
SPST
DPST
7000
33
24 Hour
20
75
Yes
Yes
12
SPST
DPST
SPDT
DPDT
3PST
40
Available
7000Z
35
24 Hour
20 or 40
Minute Offset
Yes
Yes
Astronomic
1
SPST
DPST
SPDT
DPDT
3PST
40
Available
TZ
49
24 Hour
20 or 40
Minute Offset
Yes
Permanent
by circuit
Astronomic
1
DPDT
3PST
20
Standard
W
43
7 Day
60
120
Yes
Yes
2
DPDT
3PST
4PST
40
Available
TW
47
7 Day
60
120
Yes
Permanent
by circuit
2
DPDT
3PST
20
Standard
T900
45
7 Day
60
120
Yes
Permanent
by circuit
2 SPDT
3 SPDT
20
Standard
1847A
41
24 Hour
20
75
Yes
1847AZ
41
24 Hour
1847AW
41
7 Day
20 or 40
Minute Offset
60
120
8000
37
24 Hour
15
8000
39
6, 12, 30
& 60 Min.
Varies by dial
6 sec. to 1 min.
WH2
40
24 Hour
20
TORK 27
15
75
Yes
Yes
Yes
Yes
Available
Yes
Photo
Control
Astronomic
DPST
DPDT
For applications requiring many ON/OFF
cycles per day, captive tabs on this dial tilt
in and out just using your fingertip!
TU40
SPST
SPDT
CAPTIVE TABS – DUTY CYCLE DIAL
40
SPRING WOUND RESERVE
40
SPDT
2
12
SPDT, Momentary Contact
10
Available
1
SPDT, Momentary Contact
10
Available
2
SPDT, Momentary Contact
10
Available
48
SPDT
20
30/dial
SPDT
20
12
DPST
40
Available
FIELD UPGRADEABLE
ASTRONOMIC DIALS
All Tork 24 Hour Time Switches can
be upgraded in the field to astronomic
operation.
During power outages, precision spring
mechanism takes over instantly and
automatically. Keeps the mechanism on
time up to 16 hours on 24 hour models
and up to 24 hours on 7 day models.
No resetting is needed after power
resumes, and field installation is easy!
ENCLOSED MOTOR
Time switch motors are enclosed to
protect from dust and damage.
REMOVABLE DOOR
Tork time switches feature removable
doors to provide easy access for
installation and wiring.
TORK® Electromechanical
Controls are designed and
manufactured with components
which adhere to the highest
industry standards. Trained
personnel and in-process quality
procedures ensure that every
unit meets our strictest quality
standards.
TORK 28
TU40 SERIES
UNIVERSAL MULTI-VOLTAGE
SAME ON/OFF TIMES EACH DAY
24 HOUR TIME SWITCH
NEW!
MORE WIRING
SPACE!
CONTACT RATINGS
SPECIFICATIONS
INPUT VOLTAGE: 120/208-240/277VAC,
60Hz (auto detection).
TIMING ACCURACY: Line frequency.
VOLTAGE
NO
NC
General Purpose
120-277VAC
40A
30A
Inductive
120-277VAC
30A
15A
Ballast
120VAC
277VAC
30A
20A
10A
10A
Tungsten
120VAC
15A
120VAC
240VAC
120VAC
240VAC
1HP, 30FLA, 90LRA
2HP, 20FLA, 60LRA
720VA
720VA
Resistive
28VDC
20A
Max above 104°F
120-277VAC
30A
TERMINAL RANGE: #8 - #18 AWG.
OPERATING TEMPERATURE:
-31°F to 116°F (-35°C to +47°C).
APPLICATIONS
POWER CONSUMPTION: 6 watts maximum.
Lighting
Pumps
Signs
Air conditioning
Water heaters
Fans
RATING
TYPE
ENCLOSURE: Polycarbonate Indoor/Outdoor
NEMA 3R or -Y suffix metal indoor NEMA 1
enclosure. Both with lockable hasp standard (see
page 153 for enclosure dimensions).
Motor Load
Pilot Duty
¼HP, 12FLA, 30LRA
½HP, 12FLA, 33LRA
290VA
360VA
WIRING DIAGRAMS
DTU40
ORDERING INFO
FEATURES
MULTI-VOLTAGE: Automatic input voltage
detection.
EASY SET: Real time clock face and day/night
markings for setting trippers.
Typical
Wiring
Diagram,
Application
Typical
Wiring
Diagram,
120120/277VAC
VAC Application
CATALOG
NO.
UPC
CODE
TIMER SUPPLY
(VAC) 60Hz
DRY CONTACTS
(UNPOWERED)
TU40
24000
120/208-240/277
DPDT
TU40-Y
24001
120/208-240/277
DPDT
ENCLOSURE
TYPE
Plastic Indoor/Outdoor
NEMA 3R
Metal Indoor
NEMA 1
TIMER
SUPPLY
H
N
NC
NO
C
NC
LOAD
L
N
N
NO
C
LOAD
L
N
L
Typical Wiring Diagram, 208-240 VAC Application
SCHEDULING: Minimum ON is setting 15
minutes. Dial has 96 captive trippers.
TIMER
SUPPLY
H
4 in 1 CONTACTS: DPDT can also wire as SPST,
SPDT, & DPST.
N
NC
NO
C
NC
NO
C
LOAD
BYPASS SWITCH: Sets timer to permanent
ON, OFF or timer operation.
L1
L2
L1
VACATION MODE: Set timer OFF with no
change of tripper settings.
L2
DTWH40
INDICATING LIGHTS: Power ON green and
load ON red and LED indicators.
Typical
Wiring120
Diagram,
120VAC
Typical
Wiring
Diagram,
120/277VAC
Application
Typical
Wiring
Diagram,
VAC Application
TIMER
SPECIFICATION WRITER’S GUIDE
SUPPLY
Furnish and install, where shown, a TORK time switch with
24 hour dial. The Time switch input shall be multi-voltage input 120/208/240/277VAC. Time Switch
H N
NC NO C
NC NO C
contacts shall be capable of switching 40 amperes per pole continuously up to 277 volts, and shall be DPDT, covering SPST, SPDT and DPST applications as
LOAD96 trippers permits
LOAD
required. Captive ON/OFF trippers shall accomplish 1-48 operation per day.
15 minutes switching changes. Enclosure shall be Heavy duty
lockable plastic Indoor/Outdoor NEMA 3R surface type, finished in beige, with combination 1⁄2”, 3⁄4” knockouts on bottom sides and back. Provisions shall be
N
L shall be TORK Model TU40_.
made for positive padlocking. Terminal shall be capableL of receiving
#8-#18N AWGL wire. The TimeN Switch
Typical Wiring
208-240
VAC Application
Typical Diagram,
Wiring Diagram,
240VAC
TIMER
SUPPLY
H
ELECTROMECHANICAL
CONTROLS
TORK 29
N
NC
NO
C
NC
NO
C
LOAD
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
L1
L2
L1
L2
TORK 30
1100 SERIES
SAME DAY ON/OFF
TIMES EACH DAY
24 HOUR TIME SWITCH
SPECIFICATIONS
CONTACT RATINGS
INPUT VOLTAGE: 120 or 208-277 VAC
60 Hz, varies by model.
TYPE
APPLICATIONS
Lighting
Pumps
Signs
Air conditioning
Water heaters
Fans
Automatic ON/OFF control
when operation is required at
the same time every day.
FEATURES
SCHEDULING: Minimum ON is setting 20
minutes with a minimum OFF setting of 75
minutes. Dial accommodates up to 12 pairs of
trippers. One pair included.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF automatic
operation then resumes.
ELECTROMECHANICAL
CONTROLS
TORK 31
ENCLOSURE
TYPE
CATALOG
NO.
UPC
CODE
INPUT SUPPLY
(VAC) 60Hz
OUTPUT
CONTACTS
1101
10011
120
SPST
1101-N
10040
120
SPST
1101-NC
10053
120
SPST
1101-O
10015
120
SPST
Metal Indoor
NEMA 1
Noryl® Indoor/Outdoor
NEMA 3R
Noryl® Indoor/Outdoor
w/ clear Lexan® cover
Metal Indoor/Outdoor
NEMA 3
1101-M
10022
120
SPST
Mechanism
1101-M-IAP
10052
120
SPST
1101-7
10033
347
SPST
1102
10012
208-277
SPST
1102-N
10045
208-277
SPST
1102-O
10046
208-277
SPST
Mechanism and
mounting plate
Metal Indoor
NEMA 1
Metal Indoor
NEMA 1
Noryl® Indoor/Outdoor
NEMA 3R
Metal Indoor/Outdoor
NEMA 3
1102-M
10035
208-277
SPST
Mechanism
1103
10013
120
DPST
1103-N
10041
120
DPST
1103-NC
10054
120
DPST
1103-O
10016
120
DPST
Metal Indoor
NEMA 1
Noryl® Indoor/Outdoor
NEMA 3R
Noryl® Indoor/Outdoor
w/ clear Lexan® cover
Metal Indoor/Outdoor
NEMA 3
1103-M
10023
120
DPST
Mechanism
1104
10014
208-277
DPST
1104-N
10042
208-277
DPST
1104-NC
10055
208-277
DPST
1104-O
10017
208-277
DPST
Metal Indoor
NEMA 1
Noryl® Indoor/Outdoor
NEMA 3R
Noryl® Indoor/Outdoor
w/ clear Lexan® cover
Metal Indoor/Outdoor
NEMA 3
1104-M
10014
208-277
DPST
Mechanism
1104-M-IAP
10051
208-277
DPST
Mechanism
and mounting plate
Replacement
Trippers
Order #P47 for a pair of ON/OFF trippers
Replacement
Motor
#101 (120V) & #201 (208-277V)
For Astronomic Conversion: Order #Z KIT
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
40A
TERMINAL RANGE: #8 - #14 AWG.
Resistive
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
Tungsten
120VAC
40A
Inductive
120, 277VAC
single phase
20A
Pilot Duty
120 -277VAC
1000VA
Motor
120VAC
240VAC
2HP
5HP
POWER CONSUMPTION:
3 watts maximum.
ORDERING INFO
120 -277VAC
single phase
120 -277VAC
single phase
General Purpose
TIMING ACCURACY: Line frequency.
CONTACT
RATING
VOLTAGE
ENCLOSURE: Lockable hasp. Type varies
by model (see page 153 for enclosure
dimensions).
40A
Model 1101-7 is 30 AMP inductive at 347 volts and CSA only.
OTHER MOUNTINGS:
Intermatic® Adaptor Plate model #IAP allows
any 1100 series to fit into an Intermatic case.
WIRING DIAGRAMS
1101 & 1102 (SPST)
1103 (DPST)
M
Removable
Bridge
M
L
L
1
H
2
X
LOAD
N
For separate motor terminals
remove bridge from terminals 1 & L.
M
L
H
H
TYPICAL FOR
240V SUPPLY
1
H
N
H
LOADS
M
1104 (DPST) (Both)
2
X
LOAD
2
X
1
Must be
same phase
H
L
H
1
X
2
LOAD
LOAD
N
TYPICAL FOR
277V SUPPLY
Typical for double pole
Cut motor lead at 1
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, a TORK time switch with 24 hour dial. The time switch shall be powered by a self-starting synchronous motor. Time switch
contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST as required). Removable ON/OFF trippers shall
make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 75 minutes between one OFF period and the next. Enclosure
shall be NEMA 1 surface type, finished in beige enamel, with combination 1⁄2”, 3⁄4” knockouts on bottom, both sides and back. Provision shall be made for
positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time switch shall be TORK Model 11_ _ (11_ _–_, etc, to fit requirement).
TORK 32
7000 SERIES
CONTACT RATINGS
SPECIFICATIONS
WITH SKIP-A-DAY FEATURE
RESERVE POWER OPTIONAL
24 HOUR TIME SWITCH
TYPE
INPUT VOLTAGE: 120 or 208-277 VAC
60 Hz varies by model.
TERMINAL RANGE: #8 - #14 AWG.
Resistive
120 -277VAC
single phase
120 -277VAC
single phase
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
Tungsten
120VAC
40A
Inductive
120, 277VAC
single phase
20A
Pilot Duty
120 -277VAC
1000VA
Motor
120VAC
240VAC
2HP
5HP
General Purpose
TIMING ACCURACY: Line frequency.
CALIFORNIA Title 24
APPLICATIONS
ASHRAE 90.1
POWER CONSUMPTION: 3 watts,
5 watts for “L” models maximum.
Lighting
Heating
Pumps
Air conditioning
Signs
ENCLOSURE: Lockable hasp. Type varies
by model (see page 153 for enclosure
dimensions).
NEW!
FEATURES
NEW!
SCHEDULING: Minimum ON setting is
20 minutes with minimum OFF setting at
75 minutes. Dial accommodates up to 12
pairs of trippers. One pair included.
SKIP-A-DAY: Omit operations on any
day with a 7-spoke wheel marked with
days of week. 3 omitting screws included.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
OPTIONAL RESERVE POWER: “L”
models keep dial on time up to 16 hours
during power outage.
ELECTROMECHANICAL
CONTROLS
TORK 33
CATALOG
NO.
UPC
CODE
INPUT SUPPLY
(VAC) 60Hz
OUTPUT
CONTACTS
7100
10001
120
SPST
7102
10002
208-277
SPST
7200
11001
120
DPST
7200-O
10512
120
DPST
7202
11002
208-277
DPST
7202-O
10509
208-277
DPST
7300
7302
12001
12002
120
208-277
3PST
3PST
7120
13001
120
SPDT
7122
13002
208-277
SPDT
7220
14001
120
DPDT
7222
14002
208-277
DPDT
ENCLOSURE
TYPE
Metal Indoor
NEMA 1
Metal Indoor
NEMA 1
Metal Indoor
NEMA 1
Metal Indoor/Outdoor
NEMA 3
Metal Indoor
NEMA 1
Metal Indoor/Outdoor
NEMA 3
Metal Indoor/Outdoor
NEMA 3
Metal Indoor/Outdoor
NEMA 3
Metal Indoor
NEMA 1
Metal Indoor
NEMA 1
Metal Indoor
NEMA 1
Metal Indoor
NEMA 1
Metal Indoor
NEMA 1
Metal
Indoor
7202L
19004
208-277
DPST
NEMA 1
Metal Indoor/Outdoor
7300L
19005
120
3PST
NEMA 3
Metal
Indoor/Outdoor
7302L
19006
208-277
3PST
NEMA 3
Metal
Indoor
7120L
19007
120
SPDT
NEMA 1
Metal Indoor
7220L
19009
120
DPDT
NEMA 1
Metal
Indoor
7222L
19011
208-277
DPDT
NEMA 1
Replacement Order #P49 for a pair of ON/OFF per dial. Additional ON/OFF trippers per
Trippers
dial order #P47. 3 omitting screws #53005 supplied.
Replacement
#101 (120V) & #201 (208-277V). For "L" models #36 (120V) & #46
(208-277V). For Astronomic Conversion: Order #Z KIT for 7000 Series.
Motor
19003
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
120
40A
WIRING DIAGRAMS
7100 SPST
7200 DPST
7100 SPST
M
M
M
7300 3PST
7200 DPST
L
L
L
2
L
H
H
N
X
L
1
2
LOAD
H
N
H
7120 SPDT
2
X
M
X
1
L
LOAD
LOAD
H
N
H
2
L
3
L
L
L
5
L
6
L
DPST
H
1
LOAD
X
L
H
A
N
LOAD
B
N
2
1
L
H
LOAD
X
LOAD
A
B
N
2H
H
N
H
1
L
N
3
LOAD
N
5
LOAD
6
LOAD
LOAD
LOAD
7302 3PST
7120Z (SPDT)
M
M
X
L
H
H
4
LOAD
L
1
3
M
M
M
L
2
N
7220
DPDT (DPST)
7200Z
7220 DPDT
M
X
1
4
L LOAD
N
7120 SPDT
M
2
LOAD
LOAD
LOAD
N
1
7300 3PST
M
M
WITH RESERVE POWER
7200L
40A
OTHER MOUNTINGS:
Intermatic® Adaptor Plate model #IAP
allows any 7100 and 7200 series (except
“L” models) to fit into an Intermatic case.
ORDERING INFO
Automatic ON/OFF control
when operation is required at
the same time every day, with
optional versatility of one to six
days omission.
CONTACT
RATING
VOLTAGE
5
N
2
2
X
LOAD
L
4
H
X
1LOAD
LOAD
LOAD
3
LOAD
LOAD
2
L
N
5
H
LOAD
N
L
1
3H
2
L
4
H
L
6
LOAD
LOAD
N
1
X
2
H
LOAD
5
N
4
X
LOAD
LOAD
LOAD
A
LOAD
B
N
H
FOR USE WITH 3 PHASE 4-WIRE
N
120/208V
SYSTEMS.
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, a TORK time switch with 24 hour dial and day-omitting device. The time switch shall be powered by a self-starting synchronous
motor. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPST, SPDT, as required).
Removable ON/OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 75 minutes between one OFF
period and the next. Enclosure shall be NEMA 1 surface type, finished in beige enamel, with combination 1⁄2”, 3⁄4” knockouts on bottom, both sides and back.
Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time Switch shall be TORK Model 7_ _ _ (to fit requirement).
FOR RESERVE POWER (MODELS WITH SUFFIX “L”): Spring-driven reserve shall be provided sufficient to operate the time switch contacts at least 16 hours after
power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.
TORK 34
7000Z SERIES
ADJUSTS TO DAILY CHANGES
IN SUNSET TIMES!
WITH SKIP-A-DAY FEATURE
RESERVE POWER OPTIONAL
ASTRONOMIC TIME SWITCH
CONTACT RATINGS
SPECIFICATIONS
TYPE
INPUT VOLTAGE: 120 or 208-277 VAC
60 Hz, varies by model.
TERMINAL RANGE: #8 - #14 AWG.
Resistive
120 -277VAC
single phase
120 -277VAC
single phase
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
Tungsten
120VAC
40A
Inductive
120, 277VAC
single phase
20A
Pilot Duty
120 -277VAC
1000VA
Motor
120VAC
240VAC
2HP
5HP
General Purpose
TIMING ACCURACY: Line frequency.
CALIFORNIA Title 24
APPLICATIONS
ASHRAE 90.1
POWER CONSUMPTION: 3 watts,
5 watts for “L” models maximum.
Parking lots
Walkways
Outdoor signage
Window displays
Canopy lighting
Landscape lighting
ENCLOSURE: Lockable hasp. Type varies
by model (see page 153 for enclosure
dimensions).
Automatic ON at dusk, OFF
at dawn. Control of outdoor
lighting.
42°
ORDERING INFO
SKIP-A-DAY: Omit operations on any
day with a 7 spoke wheel marked with
days of the week. 3 omitting screws
included.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
OPTIONAL RESERVE POWER: “L”
models keep dial on time up to 16 hours
during power outage.
CATALOG
NO.
7200Z–*
7202Z–*
7300Z–*
7302Z–*
7120Z–*
UPC
CODE
INPUT SUPPLY
(VAC) 60Hz
**
**
120
208-277
**
**
120
208-277
**
120
OUTPUT
CONTACTS
DPST
DPST
3PST
3PST
SPDT
ENCLOSURE
TYPE
Noryl® Indoor/Outdoor
NEMA 3R
Noryl® Indoor/Outdoor
NEMA 3R
Metal Indoor/Outdoor
NEMA 3
Metal Indoor/Outdoor
NEMA 3
Noryl® Indoor/Outdoor
NEMA 3R
WITH RESERVE POWER
7200ZL–*
**
120
DPST
7202ZL–*
**
208-277
DPST
7300ZL–*
**
120
3PST
7302ZL–*
**
208-277
3PST
7120ZL–*
**
120
SPDT
7122ZL–*
**
208-277
SPDT
Replacement
Motor
Noryl® Indoor/Outdoor
NEMA 3R
Noryl® Indoor/Outdoor
NEMA 3R
Metal Indoor/Outdoor
NEMA 3
Metal Indoor/Outdoor
NEMA 3
Noryl® Indoor/Outdoor
NEMA 3R
Noryl® Indoor/Outdoor
NEMA 3R
#101 (120V) & #201 (208-277V).
For "L" models #36 (120V) & #46 (208-277V)
*Add degrees latitude to complete number (18, 30, 34, 38, 40, 42, or 45).
**Consult factory for UPC number.
ELECTROMECHANICAL
CONTROLS
TORK 35
40A
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
40°
H
N
H
38°
WASHINGTON
OREGON
L
7120Z (SPDT)
M
M
45°
ASTRONOMIC SCHEDULING: Turn
ON at sunset and OFF at sunrise daily.
OFF time can be set from 8:30PM to
2:30AM. Can be individually offset +/- 20
or 40 minutes from both sunset and OFF
times. Available from 18° - 45° northern
latitudes.
40A
WIRING DIAGRAMS
ASTRONOMIC LATITUDE
ZONES
7200Z (DPST)
7302
3PST
FEATURES
CONTACT
RATING
VOLTAGE
X
2
UTAH
LOAD
WISCONSIN
KANSAS
L
L
3
ILLINOIS
ARIZONA
L
NEW MEXICO
IND
MISSOURI
ARKANSAS
N
L
RHODE ISLAND
H
DELAWARE
MARYLAND
VIRGINIA
6
LOAD
LOAD
B
1
N
H
N
H
7302 3PST
FLORIDA
18° HAWAII
LOAD
A
N
LOAD
L
2
X
2
LOAD
LOAD
GEORGIA
LOUISIANA
30°
X
H
FOR USE WITH 3 PHASE 4-WIRE
7200Z
(DPST)
120/208V SYSTEMS.
MEXICO
1
CONNECTICUT
NEW JERSEY
NORTH CAROLINA
SOUTH
LOAD
CAROLINA
ALABAMA
MASS
PENNSYLVANIA
4
OHIO
KENTUCKY
TENNESSEE
MISS
TEXAS
NH
WEST
VIRGINIA
5
OKLAHOMA
VT
2
NEW YORK
CALIFORNIA
34°
X
1
M
MAINE
IOWA
COLORADO
LOAD
M
MICHIGAN
L
WYOMING
NEBRASKA
NEVADA
MINN
SOUTH DAKOTA
IDAHO
1
NORTH DAKOTA
MONTANA
7200Z (DPST)
18° PUERTO
M
7120Z (SPDT)
M
M
RICO
L
L
1
X
L
H
N
H
LOAD
1
X
2
2
LOAD
3
L
4
5
6
LOAD
X
LOAD
A
LOAD
B
2
H
H
L
L
1
LOAD
LOAD
N
N
N
FOR USE WITH 3 PHASE 4-WIRE
120/208V SYSTEMS.
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, a TORK time switch with Astronomic dial and day-omitting device powered by a self-starting synchronous motor. Time switch
contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be (DPST, 3PST or SPDT) as required. ON operation shall occur
automatically at sunset (in city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and
OFF shall have a range of adjustability of 20-40 minutes before or after sunset and sunrise. Enclosure shall be: DPST or SPDT is NEMA 3R indoor/outdoor –
Noryl® – 3PST is NEMA 3 metal indoor/outdoor. Terminals shall be of the pressure type, capable of receiving #8 AWG wire. Time switch shall be TORK Model
7_ _ _Z (to fit requirement).
FOR RESERVE POWER (Add Suffix L): Spring driven reserve shall be provided sufficient to operate the time switch contacts for at least 16 hours after power
failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.
TORK 36
8000 SERIES
CONTACT RATINGS
SPECIFICATIONS
MANY DAILY ON/OFF
OPERATIONS PER DAY
DUTY CYCLE
24 HOUR TIME SWITCH
INPUT VOLTAGE: 120, 208-277VAC or
480VAC, 60Hz, varies by model.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
ORDERING INFO
ENCLOSURE
TYPE
CATALOG
NO.
UPC
CODE
INPUT SUPPLY
(VAC) 60Hz
OUTPUT
CONTACTS
8001
70001
120
SPDT
8001-N
70025
120
SPDT
8001-NC
70009
120
SPDT
Metal Indoor
NEMA 1
Noryl® Indoor/Outdoor
NEMA 3R
Noryl® Indoor/Outdoor NEMA
3R w/ clear Lexan® cover
8001-LC/WB
70010
120
SPDT
Mechanism and bracket
8001-O
70029
120
SPDT
8004
70002
208-277
SPDT
8001U
70003
480/120 Trans.
SPDT
NEW!
8001U-N
70014
480/120 Trans.
SPDT
NEW!
8001U-O
70011
480/120 Trans.
SPDT
Metal Indoor/Outdoor
NEMA 3
Metal Indoor
NEMA 1
Metal Indoor
NEMA 1
Noryl® Indoor/Outdoor
NEMA 3R
Metal Indoor/Outdoor
NEMA 3
DUTY CYCLE: Adjustable from 1⁄2, 1, 2,
3, 4, 6, 12, and 24 hours.
24 HOUR WITH 7 DAY OMIT
70005
120
SPDT
8007-O
70012
120
SPDT
8008
70006
208-277
SPDT
NEW!
8007U
70008
480/120 Trans.
SPDT
NEW!
8007U-0
70028
480/120 Trans.
SPDT
Metal Indoor
NEMA 1
Metal Indoor/Outdoor
NEMA 3
Metal Indoor
NEMA 1
Metal Indoor
NEMA 1
Metal Indoor/Outdoor
NEMA 3
24 HOUR WITH 7 DAY OMIT & RESERVE POWER
8007L
70015
120
SPDT
8008L
70016
208-277
SPDT
Metal Indoor
NEMA 1
Metal Indoor
NEMA 1
24 HOUR WITH 14 DAY OMIT
8007V
70007
120
SPDT
Metal Indoor
NEMA 1
SPDT
Metal Indoor
NEMA 1
24 HOUR WITH 14 DAY OMIT & RESERVE POWER
8007VL
Replacement
Motor
TORK 37
120 or 240VAC
480VAC
20A
20A
Motor
120VAC
3/4 HP
OTHER MOUNTINGS: Intermatic®
Adaptor Plate model #IAP allows 8001 &
8004 to fit into an Intermatic case.
WIRING DIAGRAMS
70017
120
M
ALL SPDT
MODELS
C
L
H
8007
SKIP-A-DAY: Some models include 7
day or 14 day wheel to omit selected days
of the week.
ELECTROMECHANICAL
CONTROLS
Resistive
ENCLOSURE: Lockable hasp. Type varies
by model (see page 153 for enclosure
dimensions).
8001-N
FEATURES
OPTIONAL RESERVE POWER: “L”
models keep dial on time up to 16 hours
during power outage.
CONTACT
RATING
POWER CONSUMPTION: 3 watts,
5 watts for “L” models maximum.
For one or multiple daily
ON/OFF operations.
SCHEDULING: Minimum ON setting is
15 minutes with minimum OFF setting at
15 minutes. Dial accommodates up to 96
captive tabs.
VOLTAGE
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
APPLICATIONS
Duty cycling
Ventilating fans
Pumping
Irrigation
Process control
Laboratory experiments
TYPE
120VAC
N
NC
NO
2
LOAD 2
CLOSED WITH
TAB OUTWARD
LOAD 1
CLOSED WITH
TAB INWARD
SPECIFICATION WRITER’S GUIDE
The time switches shall be of duty cycle type, capable of programming at 15 minute intervals of the day. Scheduled tabs shall be captive on the dial, and shall
be easily set by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike.
The unit shall be powered by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism
shall be a self-contained unit rated at not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the field. FOR 8001 ADD:
The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of the
time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork
Model 8007 or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit,
which shall power the clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The
unit shall be furnished with built-in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.
#101(120V) & #201 (208-277V).
For “L” models #36 (120V) & #46 (208-277V)
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 38
8000 SERIES
SPECIFICATIONS
MULTIPLE ON/OFF CYCLES PER DAY
REPEATING VARIABLE CYCLE
TIME SWITCH
INPUT VOLTAGE: 120VAC, 60Hz.
APPLICATIONS
24 HOUR WATER HEATER
TIME SWITCH
INPUT VOLTAGE: 208 – 250V 60 Hz.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
REPLACEMENT TRIPPERS: #P49 for a
pair with one ON and one OFF per dial for
additional ON/OFF trippers per dial order
#P47. 3 omitting screws #53005 supplied.
ENCLOSURE: Indoor NEMA 1 Metal with
lockable hasp (see page 153 for enclosure
dimensions).
For one or many daily ON/OFF
operations.
SPECIFICATIONS
TIMING ACCURACY: Line frequency.
POWER CONSUMPTION:
3 watts maximum.
Duty cycling
Ventilating fans
Pumping
Irrigation
Process control
Laboratory experiments
WH2
APPLICATIONS
SAVE
ENERGY!
POWER CONSUMPTION:
3 watts maximum.
Avoid utility peak rates
Turn off when not needed
Automatic ON/OFF control of
electric water heaters. Schedules
the water heater to turn ON only
when needed, avoiding energy
waste when hot water is not
needed.
ENCLOSURE: Indoor NEMA 1 Metal with
lockable hasp (see page 153 for enclosure
dimensions).
CONTACT RATINGS
CONTACT RATINGS
FEATURES
SCHEDULING: 60 captive tabs per dial
with minimum ON/OFF settings:
– 60 minute dial with 1 minute tabs.
– 30 minute dial with 30 second tabs.
– 12 minute dial with 12 second tabs.
– 6 minute dial with 6 second tabs.
TYPE
VOLTAGE
CONTACT
RATING
Resistive
120 or 240VAC
480VAC
20A
20A
Motor
120VAC
3/4 HP
CATALOG
NO.
UPC
CODE
INPUT SUPPLY
(VAC) 60Hz
OUTPUT
CONTACTS
TYPE
8601
70034
120
SPDT
60 Minute
8301
70033
120
SPDT
30 Minute
8121
70032
120
SPDT
12 Minute
C
L
H
120
SPDT
6 Minute
120VAC
N
Replacement
For 8601 #102, for 8301 #108, for 8121 #107, and for 8061 #105.
Motor
Replacement #P49 for a pair with one ON and one OFF per dial for additional ON/OFF
Trippers
trippers per dial order #P47. 3 omitting screws #53005 supplied.
ELECTROMECHANICAL
PHOTOCONTROLS
CONTROLS
TORK 39
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
NC
TYPE
VOLTAGE
CONTACT
RATING
Resistive
208-277VAC
40 A, 10,000W
Replacement Motor
#201 (208-277V)
Replacement Trippers
Order #P47 for a pair of ON/OFF trippers
EXTERNAL MANUAL OVERRIDE: Until the
next regularly scheduled ON or OFF automatic
operation then resumes.
M
ALL SPDT
MODELS
ORDERING INFO
70031
SCHEDULING: Minimum ON is setting 20 minutes
with a minimum OFF setting of 75 minutes. Dial
accommodates up to 12 pairs. 3 pairs of trippers
supplied.
WIRING DIAGRAMS
DUTY CYCLE: Settings of 1⁄60 th of dial
speed.
8061
FEATURES
WIRING DIAGRAMS
TYPICAL FOR 240
VOLT SUPPLY
ORDERING INFO
NO
2
LOAD 2
CLOSED WITH
TAB OUTWARD
CATALOG
NO.
UPC
CODE
INPUT SUPPLY
(VAC) 60Hz
OUTPUT
CONTACTS
ENCLOSURE
TYPE
WH2
70042
208-250
DPST
Metal Indoor
NEMA 1
M
H
H
L
1
2
X
LOAD
LOAD 1
CLOSED WITH
TAB INWARD
TORK 40
40
TORK
1800 SERIES
CONTACT RATINGS
SPECIFICATIONS
FOR MECHANICALLY HELD CONTRACTORS
AND LOW VOLTAGE REMOTE CONTROL
MOMENTARY CONTACT
TIME SWITCH
INPUT VOLTAGE: 120VAC or 208-277VAC, 60Hz,
varies by model.
TIMING ACCURACY: Line frequency.
TYPE
VOLTAGE
CONTACT
RATING
General Purpose
24-277VAC
10A
Pilot Duty
24-277VAC
360VA
TERMINAL RANGE: #12 - #22AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
APPLICATIONS
CALIFORNIA Title 24
Mechanically-held contactors
3-wire momentary
lighting systems
Remote station switching
POWER CONSUMPTION: 3 watts, 5 watts for
“L” models maximum.
ASHRAE 90.1
ENCLOSURE: NEMA 1 Metal with lockable hasp
(see page 153 for enclosure dimensions).
WIRING DIAGRAMS
ORDERING INFO
WASHINGTON
FEATURES
CATALOG
NO.
SCHEDULING: Choice of three types.
1847A
24 HOUR SKIP-A-DAY: Minimum ON setting
is 20 minutes with minimum OFF setting at 75
minutes. Dial accommodates up to 12 pairs of
trippers. Omit operations on any day with a 7
spoke wheel marked with days of week.
1848A
UPC
CODE
INPUT SUPPLY
(VAC) 60Hz
52001
52014
120
208-277
7 DAY SCHEDULING: Minimum ON setting is
1 hour with a minimum OFF setting of 2 hours.
Minimum 8 hours between 2 OFF settings. 7 day
calendar dial will accomodate up to 2 pairs on ON/
OFF trippers per day - 7 pairs are supplied.
MANUAL OVERRIDE: Until the next regularly
scheduled ON or OFF, automatic operation then
resumes.
TORK 41
SPDT
SPDT
TYPE
42°
24 Hour
OREGON
NORTH DAKOTA
MONTANA
MINN
MICHIGAN
WYOMING
**
120
SPDT
Astronomic
1847AW
52005
120
SPDT
7 Day
WITH RESERVE POWER
1847AL
52006
120
SPDT
24 Hour
1847AZL*
**
120
SPDT
Astronomic
1847AWL
52010
120
SPDT
7 Day
Replacement
Trippers
For 24 hour models order #P49 for a pair ON/OFF per dial. Additional ON/OFF
trippers per dial order #P47. 3 omitting screws #53005 supplied.
7 day models order #P69 for 7 pairs of ON/OFF trippers.
Replacement
Motor
#101(120V) & #201 (208-277V). For “L” models #36 (120V)
*Add degrees latitude to complete number (18, 30, 34, or 42).
**Consult factory for UPC number.
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
MAINE
WISCONSIN
SOUTH DAKOTA
IDAHO
UTAH
IOWA
NEW YORK
KANSAS
34°
IND
COLORADO
PENNSYLVANIA
OHIO
KENTUCKY
OKLAHOMA
ARIZONA
NEW MEXICO
ARKANSAS
TIMING MOTOR
120VAC, 60HZ
L
TENNESSEE
MASS
RHODE ISLAND
CONNECTICUT
DELAWARE
MARYLAND
VIRGINIA
CLOSE
COMMON
N
NEW JERSEY
WEST
VIRGINIA
MISSOURI
CALIFORNIA
ON
VT
NH
ILLINOIS
NEVADA
C
MECHANICALLY-HELD
CONTACTOR
NEBRASKA
24 Hour
1847AZ*
OPTIONAL RESERVE POWER: “L” models keep
dial on time up to 16 hours during power outage.
ELECTROMECHANICAL
CONTROLS
OUTPUT
CONTACTS
ON
OPEN
NORTH CAROLINA
SOUTH
CAROLINA
MISS
ALABAMA
TEXAS
ASTRONOMIC SCHEDULING: Turn ON at sunset
and OFF at sunrise daily. OFF time can be set from
8:30PM to 2:30AM. Can be individually offset +/20 or 40 minutes from both sunset and OFF times.
OFF
ASTRONOMIC LATITUDE ZONES
OFF
GEORGIA
LOUISIANA
MOMENTARY PUSH BUTTON
MEXICO
30°
FLORIDA
18° HAWAII
18° PUERTO
RICO
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, a Momentary Contact time switch. Time switch shall have dial of the (24 hour with day omitting device) (Astronomic with day
omitting device) (7 day calendar) type, which shall be suitable to operate mechanically-held contactor of maximum size. Terminal board shall enable fast and
correct installation using screw terminals for up to #12AWG wire. Timing motor terminals shall be completely independent from momentary switching circuit.
Spring driven reserve mechanism shall be provided sufficient to operate time switch controls at least 16 hours after power failure. On restoration of power, time
switch shall transfer to synchronous motor drive and automatically rewind reserve. Time switch shall include solid state circuit to provide a switch closure not
in excess of two seconds on both ON and OFF contactor coil terminals at such times as are set on dial: these settings to be made with removable trippers which
can be added and removed without tools (except the astronomic dial). Contactor coil circuits shall be suitable for 10 Amp @ 24-277 VAC, 360 VA. Enclosures
shall be NEMA 1 surface (or see other mountings), with provision for positive padlocking. Time switch shall be TORK Model 1847AL, 1848A, (AZL), (AWL).
TORK 42
W SERIES
CONTACT RATINGS
SPECIFICATIONS
DIFFERENT SCHEDULES EACH DAY
7 DAY TIME SWITCH
TYPE
INPUT VOLTAGE: 120 or 208-277VAC, 60Hz,
varies by model.
Resistive
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
CALIFORNIA Title 24
APPLICATIONS
ASHRAE 90.1
Heating
Air conditioning
Display lighting
Ventilating systems
Lighted signage
Storefront lighting
POWER CONSUMPTION: 3 watts, 5 watts for
“L” models maximum.
40A
120VAC
40A
Inductive
120, 277VAC
single phase
20A
Pilot Duty
120 -277VAC
1000VA
Motor
120VAC
240 VAC
2HP
5HP
ORDERING INFO
CATALOG
NO.
UPC
CODE
INPUT SUPPLY
(VAC) 60Hz
OUTPUT
CONTACTS
W100
30001
120
SPST
33001
120
ENCLOSURE
TYPE
WIRING DIAGRAMS
W100 (SPST)
W100 (SPST)
SPDT
M
W200
W202
FEATURES
31001
31011
120
208-277
SCHEDULING: Minimum ON setting is 1 hour
with a minimum OFF setting of 2 hours. Minimum
8 hours between 2 OFF settings. Models W400A
and W402A offer minimum ON/OFF settings of
31⁄2 hours. 7 day calendar dial accommodates up
to 2 pairs of ON/OFF trippers per day – 7 pairs are
supplied.
SKIP-A-DAY: Omit operations on any day.
MANUAL OVERRIDE: Until the next regularly
scheduled ON or OFF automatic operation then
resumes.
OPTIONAL RESERVE POWER: “L” models keep
dial on time up to 24 hours during power outage.
W222
W300
W300-O
W302
34001
34011
32001
32003
32002
120
208-277
120
120
208-277
L
Metal Indoor
NEMA 1
L
L
L
L
XH
N
H
LOAD
1
N
2
LOAD
H
N
H
LOAD
2
X
1
2
H
L
N
DPDT
1
LOAD
2
L
5
L
4
5
L
N
H
3PST
3PST
35001
120
4PST
W402A
35002
208-277
4PST
Equipment (4PST)
W400A
Ground
Equipment
Ground
LOAD
LOAD
Clock Motor
Supply
3
5
6
7
L
X
1
2
H
2
H
B
X
LOAD
1
LOAD
N
N H
N
L
LOAD
B
N
N
2
3
5
LOAD
LOAD
N
4
L
H 3
LOAD
N
5
4
LOAD
LOAD
H
N
W202 (DPST)
1
2
3
4
4
MOTOR
MOTOR
MOTOR
L
7
8
8
B
H
1
L
6
H
LOAD
H
5
LOAD
L
LOAD
A
2
W202MOTOR
(DPST)
A
2
X
X
M
M
A Motor1
Clock
Supply
LOAD
A
LOAD
1
L
H
H
Metal Indoor
NEMA 1
1
LOAD
1
H
H
6
W400A (4PST)
Metal Indoor/Outdoor
NEMA 3
L
LOAD
N
3PST
M
4
L
6
LOAD
2
3
L
LOAD
3
L
LOAD
2
X
M
W220 (DPDT)
M
M
L
X
1
W220 (DPDT)
W120 (SPDT)
W120 (SPDT)
DPDT
W400A
H
L
Typical for 208-240VAC
1
X
LOAD
LOAD
1
X
LOAD
H
2
LOAD
2
LOAD
Typical for 277VAC
H
Typical for 208-240VAC
Typical for 277VAC
B
WITH RESERVE POWER
W220L
39009
120
DPDT
W222L
39010
208-277
DPDT
W300L
39005
120
3PST
W302L
39006
208-277
3PST
W400AL
39007
120
4PST
Supply
Supply
Metal Indoor
NEMA 1
Replacement
Trippers
Order #P69 for 7 pairs of ON/OFF trippers
except W400 series use #P69i.
Replacement
Motor
#101 (120V) & #201 (208-277V). For W400 series units order #101i
(120V) & #201i (208-277V). For “L” models order #36 (120V)
and #46 (208-277V), except W400 series consult factory.
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
M
M
H
W220
W300 (3PST)
W300 (3PST)
M
M
DPST
DPST
W200 (DPST)
W200 (DPST)
M
TORK 43
40A
Tungsten
ENCLOSURE: Indoor NEMA 1 Metal with lockable
hasp. Other enclosures include metal Indoor/
Outdoor NEMA 3 with suffix "O" (see page 153 for
enclosure dimensions).
W120
ELECTROMECHANICAL
CONTROLS
120 -277VAC
single phase
120 -277VAC
single phase
General Purpose
TIMING ACCURACY: Line frequency.
CONTACT
RATING
VOLTAGE
To Load(s)
To Load(s)
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, TORK time switch of the 7 day type, powered by a self-starting synchronous motor, capable of being set for different ON/
OFF times each day of the week, to an operating accuracy of plus or minus 15 minutes of the desired time. Time switch contacts shall be capable of switching
40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPDT, SPDT, 4PST as required). Removable ON/OFF trippers shall make possible
automatic operation with a minimum ON period of one hour and a minimum of 2 hours between one OFF operation and the next ON. Models W400 and W402
offer minimum ON and OFF settings of 3.5 hours. Enclosure shall be NEMA 1 surface, finished in baked beige enamel, with combination 1⁄2” - 3⁄4” knock-outs
on bottom and both sides. Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time switch shall be TORK
Model W_ _ _ (to fit requirement). FOR RESERVE POWER (Add suffix L): Spring-driven reserve shall be provided sufficient to operate the Time Switch contacts
at least 24 hours after power failure (16 hour reserve power on 4PST models). On restoration of power, time switch shall transfer to synchronous motor driven
and automatically rewind reserve power unit.
TORK 44
LOAD
T900 SERIES
INPUT VOLTAGE: 120 or 208-277VAC, 60 Hz,
varies by model.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
APPLICATIONS
TYPE
VOLTAGE
CONTACT
RATING
General Purpose
120/277VAC
20A
Motor
120VAC
240VAC
1HP
2HP
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
CALIFORNIA Title 24
ASHRAE 90.1
Parking lot lighting
HVAC
Display lighting
Security lighting
Lighted signage
Storefront lighting
CONTACT RATINGS
SPECIFICATIONS
PHOTOELECTRIC & 7 DAY CONTROL COMBO
DIFFERENT SCHEDULES EACH DAY
RESERVE POWER STANDARD
2 & 3 CIRCUIT LIGHTING
CONTROL CENTERS
POWER CONSUMPTION: 5 watts maximum.
ENCLOSURE: Indoor NEMA 1 Metal with
lockable hasp. Other enclosures include cover
for access to by-pass switches with suffix "E" or
Indoor/Outdoor NEMA 3 metal with suffix "O"
(see page 153 for enclosure dimensions).
Optional "E" cover
Model 2101
supplied with unit.
WIRING DIAGRAMS
T930L
T930L
T920L
T920L
ONLYCIRCUITS
CIRCUITS1 1AND
AND2 2ARE
AREINCLUDED
INCLUDEDININT920L
T920L
ONLY
ORDERING INFO
FEATURES
CATALOG
NO.
SCHEDULING:
CIRCUIT 1: ON automatically at dusk, OFF at
individual preset times each day, including
skipping days when desired. Unit can be set to
turn ON before dawn for early morning lighting.
CIRCUIT 2: ON at dusk, OFF at dawn
automatically, daily.
CIRCUIT 3: Individual daily ON and OFF settings
at desired times, including skipping any desired
day or days Minimum ON is setting 1 hour with
a minimum OFF setting of 2 hours. Minimum 8
hours between 2 OFF settings. 7 day calendar dial
will accommodate up to 2 pairs of ON-OFF trippers
per day – 7 pairs are supplied.
SKIP-A-DAY: Omit operations on any day.
UPC
CODE
INPUT SUPPLY
(VAC) 60Hz
41033
120
2 SPDT
T920L-E
41034
120
2 SPDT
T920L-O
41035
120
2 SPDT
T930L
41055
120
3 SPDT
T930L-E
41056
120
3 SPDT
T930L-O
41057
120
3 SPDT
Metal Indoor
NEMA 1
Metal Indoor NEMA
1 with switch access
Metal Indoor/outdoor
NEMA 3
Metal Indoor
NEMA 1
Metal Indoor NEMA
1 with switch access
Metal Indoor/outdoor
NEMA 3
ON ON OFF OFF
ON ON OFF OFF
AUTO
AUTO
AUTO
AUTO
SWITCH
TIMETIME
SWITCH
OFF OFF ON ON
MM
C C
NOTE:
NOTE:
Contacts
7-12
Contacts
7-12
unpowered.
areare
unpowered.
RELAY
RELAY
PHOTOELECTRIC
PHOTOELECTRIC
CONTROL
CONTROL
ON ON OFF OFF
ON ON OFF OFF
ON ON OFF OFF
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
NOTE:
NOTE:
Contacts
4-12
Contacts
4-12
unpowered.
areare
unpowered.
RELAY
RELAY
C C
PHOTOELECTRIC
PHOTOELECTRIC
CONTROL
CONTROL
MM
CONTACTOR
CONTACTOR
CONTROL
CONTROL
CIRCUIT LINELINE
CIRCUIT
RED RED
WHITE
WHITE
BLACK
BLACK
L1 L1
OPEN
CLOSEOPEN LINELINE
CLOSE
1 1
CONTACTOR
CONTACTOR
CONTROL
CONTROL
CIRCUIT
CIRCUIT
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12
H 120V
H 120V
N N
60C 60C
LINELINE
TIME
TIME
SWITCH
SWITCH
TO DAWN
SAFETY
LIGHTS
DUSKDUSK
TO DAWN
SAFETY
LIGHTS
(PHOTOCELL
- PHOTOCELL
(PHOTOCELL
ON - ON
PHOTOCELL
OFF) OFF)
NEU.NEU.
OPEN
OPEN
CLOSE
CLOSE
H 120V
H 120V
N N
60C
BLACK 60C
BLACK
LINELINE
WHITE
WHITE
RED RED
2 2
L1 L1
LINELINE
OPEN
OPEN
OPENLINELINE
OPEN
CLOSE
CLOSE
CLOSE
CLOSE
3 3
1 1
TO DAWN
SAFETY
LIGHTS
DUSKDUSK
TO DAWN
SAFETY
LIGHTS
(PHOTOCELL
- PHOTOCELL
(PHOTOCELL
ON - ON
PHOTOCELL
OFF) OFF)
2 2
NEUNEU
OPEN
OPEN
CLOSE
CLOSE
LOAD
LOAD
LOAD
LOAD
#P69 for 7 pairs of ON/OFF trippers.
#36 (120V)
#66061
RESERVE POWER: Standard feature on all
models keep dial on time up to 24 hours during
power outage.
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.
TORK 45
ENCLOSURE
TYPE
OUTPUT
CONTACTS
MANUAL BY-PASS SWITCHES: Single pole,
20 Amps – one per circuit. Factory pre-wired to
terminal strip. ON/OFF/AUTO positions for each
circuit is independent – will not disturb automatic
settings.
ELECTROMECHANICAL
CONTROLS
MANUAL
CONTROLS
MANUAL
CONTROLS
MANUAL
CONTROLS
MANUAL
CONTROLS
T920L
Replacement
Trippers
Replacement
Motor
Replacement
Bypass Switch
ALL3 3CIRCUITS
CIRCUITSARE
AREINCLUDED
INCLUDEDININT930L
T930L
ALL
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
SPECIFICATION WRITER’S GUIDE
T900 SERIES – Furnish and install, where shown, a TORK Photo/Time Control of the 7 Day Calendar dial type, which shall be suitable to operate mechanicallyheld contactor(s). Photo/Time Control shall be pre-wired to a central terminal block which provides connecting terminals for Photocontrol and independent
contactor control circuit(s). Time switch shall function to prevent energization of lighting for preset periods each day. Time switch dial shall permit different
ON/OFF settings for each day of the week, with provision for omitting selected days. Control shall include pre-wired manual switching for each contactor circuit
specified. Enclosure shall be NEMA 1 surface. Photocontrol to be remotely installed in appropriate outside location. It shall be fully temperature compensated
and shall provide for time delay of at least 15 seconds to prevent false switching. Photocontrol shall operate control center to energize whenever natural lighting
falls below 1.5 - 5.5 foot candles turn on. Spring driven reserve timing motor shall be provided sufficient to operate time switch controls at least 24 hours after
power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit. FOR DUSK-TO-DAWN
LIGHTS: Control shall provide additional contactor circuit to above specifications except that it shall be responsive to Photocontrol only. Tork Model T-920L or
equal. FOR PRESET ON/PRESET OFF: Control shall provide for additional contactor circuit to above specification except that it shall be responsive to time switch
only. Tork Model T-930L.
TORK 46
TW SERIES
INPUT VOLTAGE:
120 or 208 - 277VAC, 60Hz, varies by model.
TYPE
VOLTAGE
CONTACT
RATING
General Purpose
120/277VAC
20A
Motor
120VAC
240VAC
1HP
2HP
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
CALIFORNIA Title 24
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
ASHRAE 90.1
APPLICATIONS
Heating
Air conditioning
Display lighting
Ventilating systems
Lighted signage
Storefront lighting
CONTACT RATINGS
SPECIFICATIONS
DIFFERENT SCHEDULES EACH DAY
MANUAL BYPASS SWITCHES
RESERVE POWER STANDARD
7 DAY TIME SWITCH
POWER CONSUMPTION: 5 watts maximum.
Optional "E" cover
ENCLOSURE: Indoor NEMA 1 Metal with lockable
hasp (see page 153 for enclosure dimensions).
WIRING DIAGRAMS
MANUAL CONTROLS
MANUAL
CONTROLS
ON
ON
OFF
ON
AUTO
ORDERING INFO
FEATURES
CATALOG
NO.
UPC
CODE
OUTPUT
CONTACTS
SCHEDULING: Minimum ON setting is 1
hour with a minimum OFF setting of 2 hours.
Minimum 8 hours between 2 OFF settings. 7 day
calendar dial accommodates up to 2 pairs of
ON-OFF trippers per day – 7 pairs are supplied.
TW-220L
39013
120
DPDT
TW-220L-E
39021
120
DPDT
TW-222L
39014
208-277
DPDT
SKIP-A-DAY: Omit operations on any day.
TW-300L
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
MANUAL BY-PASS SWITCHES: Single pole,
20 Amps – one per circuit. Factory pre-wired
to terminal strip. ON/OFF/AUTO positions for
each circuit is independent – will not disturb
automatic settings.
TW-302L
Replacement
Trippers
Replacement
Motor
Replacement
Bypass Switch
39016
120
3PST
208-277
3PST
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
1
2
1
#36 (120V) & #46 (208-277V)
#66061
3
ON
5
4
5
AUTO
6
6
NOTE:
Switching contacts
NOTE:
are unpowered
Switching contacts
are unpowered
OFF
OFF
AUTO
7
9
8
7
9
8
LINE
LOAD
LINE
LINE
LOAD
LOAD
LINE
N
H
N
H
TW300L
TW300L
When single line source is
When
source is
used, single
jumperline
terminals
used,
jumper
terminals
1-5-7-9 and connect all com1-5-7-9
and
connect2all
commons to
terminals
and
3.
mons to terminals 2 and 3.
LOAD
LINE
LOAD
LINE
LOAD
MANUAL CONTROLS
MANUAL
CONTROLS
ON
OFF
ON
1
2
1
H
3
4
OFF
TW220L
TW220L
OFF
AUTO
AUTO
TIME
SWITCH
TIME
SWITCH
2
4
3
M
M
ON
ON
OFF
AUTO
AUTO
5
5
6
6
7
7
8
8
CONTACTOR
CONTROL
CONTACTOR
CIRCUIT
9
CONTROL
CIRCUIT
9
N
H
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.
TORK 47
Metal Indoor
NEMA 1
Metal Indoor NEMA
1 with switch access
Metal Indoor
NEMA 1
Metal Indoor
NEMA 1
Metal Indoor
NEMA 1
Order #P69 for 7 pairs of ON/OFF trippers.
RESERVE POWER: Standard feature on all
models keep dial on time up to 24 hours during
power outage.
ELECTROMECHANICAL
CONTROLS
ENCLOSURE
TYPE
M
ON
OFF
OFF
AUTO
AUTO
TIME
SWITCH
TIME
SWITCH
2
4
3
M
INPUT SUPPLY
(VAC) 60Hz
39015
ON
OFF
AUTO
N
CONTACTOR
CONTROL
CONTACTOR
CIRCUIT
CONTROL
CIRCUIT
COMMON
OPEN
COMMON
CLOSE
OPEN
CLOSE
COMMON
COMMON
OPEN
CLOSE
OPEN
Wiring shown is for mechaniWiring
shown
is for mechanically-held
contactors.
Use
cally-held
contactors.
CLOSE terminal
onlyUse
for magCLOSE
terminalcontactors
only for magnetically-held
and
netically-held
contactors
and
to control direct
loads not
toexceeding
control direct
loads
not
2000
watts.
exceeding 2000 watts.
CLOSE
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, a TORK time switch of the 7 day type, capable of being set for different ON/OFF times each day of the week, to an operating accuracy
of plus or minus 15 minutes of the desired time. The time switch shall be powered by a self-starting synchronous motor with spring-driven reserve, which shall be
sufficient to operate the time switch contacts at least 24 hours after power outage. On restoration of power, time switch shall transfer to synchronous motor drive and
automatically rewind reserve power unit. Time switch shall provide for automatic operation with a minimum of one hour between an ON/OFF operation with minimum
of four ON/OFF operations per day. ON/OFF operations shall be accomplished by removable ON/OFF trippers on the dial. Time switch contacts shall be capable of
carrying a minimum 20 amperes per pole continuously at 277 volts and shall be DPDT or 3PST. Manual switches shall be provided as an integral part of the time switch,
one for each pole, and shall permit manual switching to maintained ON or OFF positions until manually returned to AUTOMATIC position. Terminal strip shall be capable
of receiving #10AWG wires. Enclosure shall be NEMA 1 surface type, finished in beige enamel, and with 1⁄2” - 3⁄4” combination knock-outs on bottom, both sides and
top. Provision shall be made for positive padlocking. (Specify “E” door for manual switches to be accessible when case is locked). Shall be TORK Model TW (to fit switch
requirement) or equal in general purpose NEMA 1, (general purpose metal) or (Indoor/Outdoor NEMA 3) enclosure.
TORK 48
TZ SERIES
CONTACT RATINGS
SPECIFICATIONS
MANUAL BYPASS SWITCHES
RESERVE POWER STANDARD
ASTRONOMIC TIME SWITCH
INPUT VOLTAGE:
120 or 208 - 277VAC, 60Hz, varies by model.
TYPE
VOLTAGE
CONTACT
RATING
General Purpose
120/277VAC
20A
Motor
120VAC
240VAC
1HP
2HP
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE:
-40˚ to 165˚F (-40˚ to +74˚C).
CALIFORNIA Title 24
APPLICATIONS
ASHRAE 90.1
POWER CONSUMPTION: 5 watts maximum.
Schools
Industrial yards
Shop windows
Parking lots
Highway signs
Bridges
ENCLOSURE: Indoor NEMA 1 Metal with
lockable hasp and for some models enclosures
is Indoor/Outdoor NEMA 3 metal with suffix "O"
(see page 153 for enclosure dimensions).
WIRING DIAGRAMS
ASTRONOMIC LATITUDE ZONES
45°
42°
ORDERING INFO
FEATURES
SCHEDULING: Turn ON at sunset and OFF at
sunrise daily. OFF time can be set from 8:30PM
to 2:30AM. Can be individually offset +/- 20
or 40 minutes from both sunset and OFF times.
Available from 18° - 45° northern latitudes.
SKIP-A-DAY: Omit operations on any day with
a 7 spoke wheel marked with days of the week.
3 omitting screws included.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
MANUAL BYPASS SWITCHES: Single pole,
20 Amps - one per circuit. Factory pre-wired to
terminal strip. ON/OFF/AUTO positions for each
circuit is independent, will not disturb automatic
settings.
CATALOG
NO.
TZ-220L*
TZ-220L-O*
UPC
CODE
**
**
INPUT SUPPLY
(VAC) 60Hz
40°
OUTPUT
CONTACTS
120
DPDT
120
DPDT
TZ-222L*
**
208 - 277
DPDT
TZ-300L*
**
120
3PST
TZ-300L-O*
TZ-302L*
Replacement
Motor
Replacement
Bypass Switch
**
**
120
3PST
208 - 277
3PST
Metal Indoor
NEMA 1
Metal Indoor/outdoor
NEMA 3
Metal Indoor
NEMA 1
Metal Indoor
NEMA 1
Metal Indoor/outdoor
NEMA 3
Metal Indoor
NEMA 1
34°
NOTE:
Switching contacts
NOTE:
are unpowered
Switching contacts
are unpowered
AUTO
WASHINGTON
OREGON
NORTH DAKOTA
MONTANA
MINN
WYOMING
MAINE
WISCONSIN
SOUTH DAKOTA
IDAHO
AUTO
MICHIGAN
NH
NEW YORK
NEBRASKA
ILLINOIS
NEVADA
UTAH
IND
COLORADO
KANSAS
PENNSYLVANIA
OHIO
KENTUCKY
ARIZONA
NEW MEXICO
ARKANSAS
TENNESSEE
RHODE ISLAND
CONNECTICUT
VIRGINIA
DELAWARE
MARYLAND
M
2
1
3
5
4
5
6
6
7
7
9
8
LINE
LOAD
LINE
LINE
LOAD
LOAD
LINE
LINE
LOAD
LOAD
LINE
LOAD
9
8
N
H
N
H
NORTH CAROLINA
SOUTH
CAROLINA
MISS
ALABAMA
TEXAS
1
MASS
NEW JERSEY
WEST
VIRGINIA
MISSOURI
CALIFORNIA
OKLAHOMA
M
VT
IOWA
TIME
SWITCH
TIME
2 SWITCH
4
3
GEORGIA
LOUISIANA
30°
TZ300L
TZ300L
When single line
sourcesingle
is used,
When
line
jumperis terminals
source
used,
1, 5, 7,terminals
9 and connect
jumper
1,all5,commons
7, 9 and toconnect
allterminals
commons2 and
to 3.
terminals 2 and 3.
MEXICO
FLORIDA
18° HAWAII
MANUAL CONTROLS
18° PUERTO
MANUAL CONTROLS
RICO
M
1
1
H
H
M
TIME
SWITCH
TIME
2 SWITCH
4
3
2
3
4
5
5
6
6
7
7
8
8
9
9
N
N
CONTACTOR
CONTROL
CONTACTOR
CIRCUIT
CONTROL
CIRCUIT
CONTACTOR
CONTROL
CONTACTOR
CIRCUIT
CONTROL
CIRCUIT
COMMON
OPEN
COMMON
CLOSE
OPEN
COMMON
CLOSE
OPEN
COMMON
CLOSE
OPEN
CLOSE
TZ220L
TZ220L
Wiring shown is for
mechanically
Wiring
shown isheld
for
contactors. Use
mechanically
heldCLOSE
terminal only
contactors.
Usefor
CLOSE
magnetically
held
terminal
only for
contactors and
magnetically
heldto
control direct
contactors
and loads
to not
exceeding
control
direct2000
loadswatts.
not
exceeding 2000 watts.
#66061
*Add degrees latitude to complete number (18, 30, 34, 38, 40, 42, or 45).
**Consult factory for UPC number.
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.
TORK 49
38°
For "L" models #36 (120V) & #46 (208-277V)
RESERVE POWER: Standard feature on all
models keep dial on time up to 24 hours during
power outage.
ELECTROMECHANICAL
CONTROLS
ENCLOSURE
TYPE
MANUAL CONTROLS
MANUAL CONTROLS
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
SPECIFICATION WRITER’S GUIDE
Furnish and install, where shown, a TORK time switch with Astronomic dial and day-omitting device, and a 3-way manual switch for each circuit. The time switch shall
be powered by a self-starting synchronous motor with spring-driven reserve, which shall be sufficient to operate the time switch contacts at least 16 hours after power
failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve. ON operation shall occur automatically at
sunset in (city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of
adjustability of 20 or 40 minutes before or after sunset and sunrise. Time switch contacts shall be capable of carrying a minimum of 20 amperes per pole continuously
at 277 volts and shall be DPST (3PST). Manual switches shall be provided as an integral part of the time switch, one for each pole, and shall permit manual switching
to maintained ON or OFF positions until manually returned to AUTOMATIC position. Terminal strip shall be capable of receiving #10AWG wires. Enclosure shall be NEMA
1 surface type, finished in beige enamel, and with 1⁄2” - 3⁄4” combination knock-outs on bottom, both sides and top. Provision shall be made for positive padlocking.
(Specify “E” door for manual switches to be accessible when case is locked). Time switch shall be TORK Model TZ-___ (to fit requirement).
TORK 50
DIGITAL
TIME SWITCHES
FEATURES
QUICK LOOK
DTU40
DTWH40
E-PB
E
EW
EWZ
DG
DGM
DZS
DTS
DWZ
Page No.
55
55
57
57
59
61
63
63
65
67
69
Number of Channels
1
1
1
1 or 2
1 or 2
1 or 2
1 or 2
1
1, 2, or 4
1, 2, or 4
20 (140)
20
20
20
56
56
99
ON/OFF Set Points
7 pair (98) 7 pair (98)
DW
DZM
ELC71/72 ELC74/78/712
Page No.
69
71
73
1
Number of Channels
2
2
99
99
ON/OFF Set Points
99
99
7/365 day
7/365 day
7/365 day
LIGHTING CONTROLS
CYCLE - SIGNAL TIMER
DGU
DGUM
DGLC
DLC400
DG
DGS
DIN
75
79
79
79
81
85
85
89
1 or 2
4, 8, or 12
1
1
1 or 2
4
1 or 2
1
1 or 2
128
128
56
56
56
99
56
56
8 pair
3 pair/ch
7/365 day
7/365 day
24 Hour
7 Day
7 Day
365 Day/7 Day Scheduling
7 day
7 day
24 hour
24 hour
7 day
7 day
Automatic Daylight
Savings Adjustment
Manual
Manual
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Automatic Daylight
Savings Adjustment
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Leap Year
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
24
24
24
Individual Holiday Schedules
24
24
26
26
10
10
Yes
Yes
Yes
Yes
Leap Year
7/365 day 7/365 day
ENERGY/LIGHTING
CONTROLS
Individual Holiday Schedules
Block Holiday
9
9
Season Scheduling
Block Holiday
4
Astronomic (Sunrise/Sunset)
Yes
365 Day/7 Day Scheduling 7/365 day 7/365 day
4
Yes
Yes
Season Scheduling
4
Astronomic (Sunrise/Sunset)
Yes
7/365 day 7/365 day 7/365 day 7/365 day
24
9
9
9
4
Yes
Yes
Yes
Photosensor Input
Photosensor Input
Yes
Yes
Yes
Yes
Yes
Yes
Remote Override Input
Remote Override Input
Yes
Yes
Yes
Yes
Yes
Yes
User Defined Input
User Defined Input
Yes
Yes
Signal/Pulse Duration
Yes
Yes
Yes
Yes
Yes
Yes
Signal/Pulse Duration
Yes
Momentary for Contactors
Option
Option
Option
Yes
Yes
Momentary for Contactors
Duty Cycle
Duty Cycle
31 Day Cycle
31 Day Cycle
Yes
Yes
Yes
Manual Override
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Manual Override
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Clock Format
AM/PM
AM/PM
AM/PM
AM/PM
AM/PM
AM/PM
12/24
12/24
12/24
12/24
12/24
Clock Format
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
AM/PM
7 day Super
Capacitor
7 day Super
Capacitor
Power Outage Backup
Permanent
Permanent
Permanent
Schedule Retention
without power
Yes
Yes
Power Outage Backup
Schedule Retention
without power
Rechargeable Rechargeable 4 day Super 4 day Super 4 day Super 4 day Super 7 day Super 7 day Super 7 day Super
Battery
Battery
Capacitor Capacitor
Capacitor
Capacitor Capacitor Capacitor
Capacitor
Battery
Battery
Staggered Start
Permanent Permanent
Yes
Yes
Permanent
Yes
Permanent Permanent Permanent
Yes
Yes
Yes
Memory Module
Computer Programming
Software
Output Contacts: Amps
Resistive or General Purpose
Staggered Start
Yes
Memory Module
Yes
Computer Programming
Software
Output Contacts: Amps
Resistive or General Purpose
Contact Type: Dry
Unpowered
40A
40A
30A
40A
40A
40A
20A
20A
30A/20A
30A/20A
30A
Contact Type: Dry Unpowered
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Voltage Input AC
120/208240/277
120/208240/277
120
120-277
120-277
120-277
120-277
120-277
120/208240/277
120/208240/277
120/208240/277
Low Voltage Input
(select models)
TORK 53
12VDC 24VAC
Voltage Input AC
Low Voltage Input
(select models)
7 day Super 7 day Super 7 day Super
Capacitor Capacitor
Capacitor
Permanent Permanent
Yes
Yes
2 day Capacitor 7 day Super 7 day Super 7 day Super
1 year battery Capacitor
Capacitor
Capacitor
Capacitor
Battery
Permanent
Permanent
Yes
Yes
Yes
Yes
6 month
battery
7 day Super 7 day Super
Capacitor
Capacitor
Permanent Permanent Permanent
Yes
Yes
Yes
Permanent
Yes
Yes
8 year battery
Battery
Yes
Yes
Yes
Yes
30A
30A
20A
20A
20A
20A
20A
30A
20A
20A
16A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
24/120/208
240/ 277
120-277
120-277
120-277
120/208240/277
120-277
120-277
120
12VDC
24VAC
24VAC
120/208- 120/208- 120/208-240/
240/277 240/277
277
24VAC All Models
TORK 54
DT SERIES
NEW!
AUTOMATIC VOLTAGE DETECTION
24 HOUR OR 7 DAY HOUR
TIME SWITCH
MORE WIRING
SPACE!
NEW!
INPUT VOLTAGE: 120/208-240/277
VAC, 50/60 Hz (auto detection). DTWH40 is
120/240VAC (auto detection).
TYPE
VOLTAGE
Resistive
TERMINAL RANGE: #8 - #18AWG.
OPERATING TEMPERATURE:
-31°F to 116°F (-35°C to +47°C).
APPLICATIONS
DTU40
Pumps, motors, fans
Signs and lighting
Water heaters
Heating and air conditioning
CONTACT RATINGS
SPECIFICATIONS
POWER CONSUMPTION: 6VA Max.
ENCLOSURE: DTU40 polycarbonate Indoor/
Outdoor NEMA 3R. DTWH40 polycarbonate
indoor NEMA 1 enclosure with clear cover. Both
with lockable hasp (see page 153 for enclosure
dimensions).
DTU40
DTWH40
DTWH40
Water Heaters
This timer turns OFF when rates
are high and turns OFF when no
one is home.
SAVE
ENERGY!
120-277VAC
40A
30A
Inductive
120-277VAC
30A
15A
Ballast
120VAC
277VAC
30A
20A
10A
10A
Tungsten
120VAC
15A
120VAC
240VAC
120VAC
240VAC
1HP/30FLA/90LRA
2HP/20FLA/60LRA
720VA
720VA
Resistive
28VDC
20A
Max above 104°
120-277VAC
30A
Pilot duty
1⁄4HP/12FLA/30LRA
1⁄2HP/12FLA/33LRA
290VA
260VA
Typical
Wiring
Diagram,
Application
Typical
Wiring
Diagram,
120120/277VAC
VAC Application
TIMER
SUPPLY
N
NC
CATALOG
NO.
UPC
CODE
TIMER SUPPLY
(VAC) 60Hz
NO. OF
CHANNELS
DRY CONTACTS
(UNPOWERED)
L
N
DTU40
24004
120/208-240/277
1
DPDT
DTWH40
24005
120/240
1
DPDT
H
NC
N
NO
C
LOAD
L
N
NC
NO
C
WIRING DIAGRAMS
L1
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
C
N
L
Typical Wiring Diagram, 208-240 VAC Application
TIMER
SUPPLY
DAYLIGHT SAVING: Manual button push for
one hour adjustment.
NO
LOAD
ORDERING INFO
SCHEDULING: 7 ON & OFF pairs of set points
for individual programs on each day of the
week. Minimum setting is 1 minute.
NC
DTU40
H
FEATURES
NO
Motor
Avoid utility peak rates
Turn off when not needed
RATING
NC
NO
C
LOAD
L2
L1
L2
DTWH40
DTU40
Typical
Wiring120
Diagram,
120VAC
Typical
Wiring
Diagram,
120/277VAC
Application
Typical
Wiring
Diagram,
VAC Application
EXTERNAL MANUAL OVERRIDE: DTWH40
only on clear door. Override without opening
case.
TIMER
SUPPLY
H
N
TIMER
SUPPLY
NC
NO
C
NC
LOAD
RANDOM MODE: Varies ON and OFF times to
create "lived-in" look when away.
L
CLOCK FORMAT: AM/PM.
Typical
Wiring
Diagram,
Application
Typical
Wiring
Diagram,
120120/277VAC
VAC Application
N
N
NO
C
H
L
N
L
TIMER
SUPPLY
H
N
NC
NO
C
L
N
N
L2
NO
C
LOAD
L
N
L
Typical Wiring Diagram, 208-240 VAC Application
TIMER
SUPPLY
NC
NO
C
NC
NO
C
H
N
NC
NO
C
LOAD
L1
NC
LOAD
Typical Wiring
208-240
VAC Application
Typical Diagram,
Wiring Diagram,
240VAC
POWER OUTAGE BACKUP: Battery retains
time and schedule.
N
LOAD
L1
NC
NO
C
LOAD
L2
L1
L2
L1
L2
DTWH40
Typical
Wiring120
Diagram,
120VAC
Typical
Wiring
Diagram,
120/277VAC
Application
Typical
Wiring
Diagram,
VAC Application
DIGITAL
CONTROLS
TORK 55
TIMER
SUPPLY
H
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
N
NC
NO
C
LOAD
L
N
N
NC
NO
C
LOAD
L
N
L
TORK 56
E & E-PB SERIES
CONTACT RATINGS
SPECIFICATIONS
BACK-UP WITHOUT BATTERY,
ECO FRIENDLY!
MULTIPURPOSE CONTROLS
1 OR 2 CHANNEL
24 HOUR TIME SWITCH
INPUT VOLTAGE:
E SERIES
120 - 277VAC, 50/60Hz (automatic detection).
E-PB
120VAC, 50/60Hz.
APPLICATIONS
TERMINAL RANGE: #8 - #16AWG.
E101B
Signs
Air conditioning
Lighting
Sump pumps
Ventilating fans
OPERATING TEMPERATURE:
-40° to +149°F (-40° to +65°C).
1
4CONSUMPTION: 6VA Max.
3
POWER
ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R
is standard
with lockable hasp (see page 153 for
L
N
N
120/277VAC
enclosure dimensions).
2A
120VAC
5A
720VA
720VA
720VA
120-277VAC
470VA
1HP
1HP
11⁄2HP
2HP
1HP
11⁄2HP
2HP
120VAC
240VAC
1HP
2HP
30A
30A
28VDC
20A
30A
Inductive
120-277VAC
40A
30A
30A
Ballast
120VAC
208-277VAC
30A
20A
30A
20A
Tungsten
120VAC
15A
120-277VAC
Pilot Duty
E101B
3
2
120VAC
TIMER
5
SUPPLY
LOAD 208VAC
240-277VAC
Motor4
LOAD
LOAD
L
15A
30A
SPDT
1
10A
10A
30A
12A
30A
12A
20A
6A
40A
TIMER
SUPPLY
Resistive
N
N
N
1
28VDC
SPST
11 2HP
⁄
2HP
2
3
120/277VAC
E101PB
VOLTAGE
RATING
NO
120/240VAC
277VAC
120/240VAC
277VAC
120VAC
277VAC
120-277VAC
SPST
2
E120B
RATING
NO
NC
VOLTAGE
General Purpose
E120B
TIMER
SUPPLY
E101B, E103B, E201B
RATING
NO
TYPE
TIMING ACCURACY: Line Frequency.
4
30A
E120
TIME
SUPP
1
LOAD
L
N
N
L
120/277VAC
WIRING DIAGRAMS
E103B
DPST
TIMER
SUPPLY
E101B
1
FEATURES
SCHEDULING: 20 ON/OFF set points repeat
each day. Minimum setting 1 minute.
E101B
UPC
CODE
82401
INPUT SUPPLY
(VAC) 50/60Hz
120-277
NO. OF
CHANNELS
OUTPUT
DRY CONTACTS
1
E103B
82411
120-277
1
82406
120-277
1
LEAP YEAR: Automatic Compensation.
E201B
82466
120-277
2
E101PB
82401
120-277
L
1N
N
2
3
L
TIMER
SUPPLY
L
1
4
N
E101B
2
3
4
N
5
N
3
1
2
TIMER
SUPPLY
SPST
LOAD
1
N
120/277VAC
2
N
L
6
TIMER
SUPPLY
1
LOAD
E101PB
DPST
SPDT
TIMER
SUPPLY
1
3
2
N
L
2
LOAD
4
3
4
LOAD
5
TIMER
SUPPLY
5
6
1
2
L
N
4
N
5
N
3
4
5
120/277VAC
N
2
3
4
5
6
PULSE OFF
E201B
E201B ONLY: UNIT MUST
BE CONFIGURED FOR
TIMER
MOMENTARY
OPTION.
2
L
N
N
3
TIMER
SUPPLY
LOAD
1
3
CH 1
SP
4
3
2
LOAD
N
120VAC
N
6
TIMER
SUPPLY
PULSE ON
1
L
E201B
L
L2
208 OR 240VAC
CH 1
SPST
LOAD
LOAD
1
2
L
N
MOMENTA
C
3
4
CH 2
SPST
SUPPLY
N
L
2
SPST
120/277VAC
LOAD
N
N
L
DPST
TIMER
SUPPLY
MOMENTARY CONFIGURATION
CH 1
L1
6
N
120/277VAC
1
LOAD
N
L
N
N
N 120/277VAC
4DPST
5
LOAD
LOAD
3
L
1
120/277VAC
L
N
N
TIMER
SUPPLY
LOAD
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides
4 days of real time backup.
5
6
E103B
4
3
LOAD
4
120/277VAC
TIMER
SUPPLY
LOAD
L2
3
2
L
N
SPDT
L1
208 OR 240VAC
SPST
1
2
E120B E103B
LOAD
E120B
SPST
SPDT
TIMER
SUPPLY
1
1
DPST
CH 2
SPST
LOAD
DPST
TIMER
SUPPLY
CH 1
SPST
LOAD
120/277VAC
SPST
L
CLOCK FORMAT: AM/PM.
4
5
6
N
L
N
120/277VAC
LOAD
PULSE O
E201B O
BE CON
MOMEN
120/277VAC
120/277VAC
DPST
TIMER
SUPPLY
1
E201B
1
2
4
3
5
6
LOAD
L
LOAD
N
N
N
L
120/277VAC
DPST
TIMER
SUPPLY
1
2
3
4
5
6
L2
208 OR 240VAC
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
LOAD
2
3
4
5
6
CH 1
CH 2
SPECIFICATION
SPST
SPST WRITER’S
MOMENTARY CONFIGURATION
TIMER
GUIDE
CH 1
SUPPLY
TIMER
E100B
only
–
1.
Furnish
and
install
a
TORK
digital
time
switch
with
(40
Amp
SPST
contacts,
model E101B,E201B) (40 Amp DPST contacts, model E103B) (30 Amp SPDT
SUPPLY
L1
L2
contacts,
model
E120B).
2.
Unit
shall
be
capable
of
20
set
points.
3.
Unit
shall
repeat
the
same
schedule
each day. 4. (Model E201B ONLY) Unit shall be capable of being
LOAD
208 OR 240VAC
1
2
3
4
5
6
4 maintained
5
1
2
6 a 1 channel momentary 5. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 6. Unit shall program in AM/PM
a32 channel
or
LOAD
LOAD
format. 7. Unit shall have LCD display. 8. Unit shall have permanent schedule retention. 9. Unit real time clock shall be retained by super capacitor for 100 hours in a
power failure. 10. Unit shall be capable of manual override ON or OFFL either
to thePULSE
nextON
scheduled
event or permanently. 11. Unit shall have a NEMA 3R Indoor/Outdoor
PULSE OFF
N
N L 12. Unit
Nshall have Load Status indication. 13. Unit shall have Power Failure indication. 14. To order specify TORK Model E101B (E103B) (E120B)
L
N
plastic enclosure.
120/277VAC E201B ONLY: UNIT MUST
120/277VAC
BE CONFIGURED FOR
MOMENTARY OPTION.
(E201B).
TIMER
SUPPLY
L1
DPST
TIMER
SUPPLY
E103B
MOMENTARY OPTION: For mechanically
held contractors: Model E201B only. Configure
with simple jumper change for single-channel
momentary operation.
TORK 57
TIMER
SUPPLY
120/277VAC
E120B
DIGITAL
CONTROLS
E201B
SPST
6
5
LOAD
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
4
3
2
ORDERING INFO
CATALOG
NO.
120/2
1
2
L
N
MOMENTARY CONFIGURATION
CH 1
3
4
PULSE ON
5
6
PULSE OFF
TORK 58
EW SERIES
AUTOMATIC DST - SAVES TIME
CHANGES TWICE A YEAR
MULTIPURPOSE CONTROL
1 OR 2 CHANNEL
7 DAY TIME SWITCH
SPECIFICATIONS
CONTACT RATINGS
TIMING ACCURACY: Line Frequency.
TYPE
INPUT VOLTAGE:
120 - 277VAC, 50/60Hz (automatic detection).
energy
APPLICATIONS
ASHRAE 90.1
Outdoor signs
Lighting security
Heating and air conditioning
40A
120-277 VAC
30A
30A
Inductive
120-277VAC
40A
120-277 VAC
30A
30A
Ballast
120VAC
208-277VAC
30A
20A
120VAC
208-277VAC
30A
20A
10A
10A
Tungsten
120VAC
15A
120VAC
15A
2A
Pilot Duty
120-277VAC
720VA
120-277 VAC
720VA
720VA
Motor
120VAC
208VAC
240-277VAC
SPST
1HP TIMER
120VAC
11⁄2HPSUPPLY 208VAC
2HP
240-277VAC
1HP
11⁄2HP
2HP
1HP
11⁄2HP
2HP
Resistive
28VDC
30A
30A
POWER CONSUMPTION: 6VA Max.
ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R.
EW101B
Suffix -C plastic clear cover Indoor/Outdoor NEMAEW120B
TIMER
3R. Suffix SPST
-Y metal Indoor enclosure NEMA 1. All TIMER
SUPPLY
with lockable hasp (see page 153 for enclosure SUPPLY
dimensions).
1
2
3
4
1
2
L
N
SPDT
3
LOAD
4
LOAD
5
EW101B
1
2
30A
N
N
WIRING DIAGRAMS
120/277VAC
ORDERING INFO
FEATURES
SCHEDULING: 20 ON & OFF set points
for individual programs for each day of the
week. Minimum setting is 1 minute.
DAYLIGHT SAVING:
Automatic (can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
CLOCK FORMAT: AM/PM.
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides 4
days of real time backup.
1
CATALOG
NO.
UPC
CODE
INPUT SUPPLY
(VAC) 50/60Hz
NO. OF
CHANNELS
EW101B
82431
120-277
1
SPST
EW103B
82441
120-277
1
DPST
EW120B
82436
120-277
1
SPDT
EW201B
82467
120-277
2
SPST
EW103B-C
82253
120-277
1
DPST
82255
120-277
1
L
EW120B-Y
EW201B-Y
82437
82261
82299
120-277
120-277
120-277
1
1
2
EW101B
SPST
TIMER
SUPPLY
1
2
1
3
N
3
N
120/277VAC
N
L
1
CH 2
SPST
2
120/277VAC
3
4
LOAD
PULSE OFF
LOAD
N
N
CH 1
1
2
3
4
5
1
2
N
120/277VAC
PULSE ON
L
N
N
N
DPST
momentary configuration
3
EW103B
4
5
TIMER
SUPPLY
6
1
2
DPST
1
4
3
LOAD
CH 1
TIMER
SUPPLY
5
2
3
N
LOAD
N
L
N
L
4
5
6
6
120/277VAC
N
PULSE ON
PULSE OFF
EW201B ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
120/277VAC
N
DPST
TIMER
SUPPLY
CH 1
3
1
2
L1
L2
3
4
5
6
DPST
TIMER
SUPPLY
4
5
6
LOAD
SPECIFICATION 1WRITER’S
GUIDE
4
3
5
6
2
208 OR 240VAC
EW SERIES – 1. Furnish and
installON
a TORKPULSE
digital OFF
time switch with (40 Amp SPST contacts, model EW101B, EW210B) (40 Amp DPST contacts, model EW103B) (30 Amp
PULSE
L
N
LOAD
LOAD
SPDT contacts,
model
EW120B).
2.
Unit
shall
be
capable
of 20 set points.
3. Unit shall be capable of a different schedule each day of the week. 4. (Model EW201B ONLY)
120/277VAC EW201B ONLY: UNIT MUST BE
CONFIGURED
FOR
MOMENTARY
OPTION
Unit shall be capable of being a 2 channel maintained or a 1 channel momentary. 5. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 6.
L
N
N
L
N
Unit shall program in AM/PM
format. 7. Unit shall have LCD display. 8. Unit shall have permanent schedule retention. 9. Unit real time clock shall be retained by super
120/277VAC
capacitor for 100 hours in a power failure. 10. Unit shall be capable of manual override ON or OFF either to the next scheduled event or permanently. 11. Unit shall have
DPST
TIMER
a NEMA 3R Indoor/OutdoorSUPPLY
plastic enclosure. 12. Unit shall have Load Status indication. 13. Unit shall have Power Failure indication. 14. To order specify TORK Model
EW101B (EW103B) (EW120B) (EW201B).
1
2
L1
L2
3
4
5
6
6
208 OR 240VAC
L
N
L
EW103B
TIMER
SUPPLY
CH 2
SPST
5
LOAD
momentary configuration
CH 1
SPST
N
L2
120/277VAC
EW201B
6
LOAD
208 OR 240VAC
5
EW201B ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
L
5
4
6
PULSE ON
CH 2
SPST
LOAD
TIMER
SUPPLY
SPST
TIMER
4
5
SUPPLY
2
4
LOAD
120/277VAC
L1
momentary configuration
TORK 59
2
3
2
120/277VAC
CH 1
SPDT
1
L
TIMER
SUPPLY
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
3
CH 1
4
N
MOMENTARY OPTION: For mechanically
held contractors: Model EW201B only. Configure
with simple jumper change for single-channel
momentary operation.
DIGITAL
CONTROLS
L
N
EW120B
EW201B
TIMER
SUPPLY
SPDT
SPST
2
1
PULSE OFF
EW201B ONLY: UNIT MUST BE
TIM
SU
1
L
CH 1
SPST
LOAD
momentary configuration
DPST
SPDT
1
EW
120
SUPPLY
4
N
N
EW201B
TIMER
TIMER
SUPPLY
120/277VAC
L
EW120B-C
3
N
SPDT
DPST
LOAD
LOAD
EW103B-Y
2
4
120/277VAC
EW120B
EW103B
SPST
CH 2
SPST
CH
1
TIMER
SPST
SUPPLY
L
N
120/277VAC
EW101B
EW201B
OUTPUT
DRY CONTACTS
N
3
28LOAD
VDC
LOAD
L
RATING
NO
NC
120-277VAC
OPERATING TEMPERATURE:
-40° to +149° (-40° to +65°C).
CALIFORNIA Title 24
EW120B
VOLTAGE
General Purpose
TERMINAL RANGE: #8 - #16AWG.
responsible
EW101B, EW103B, EW201B
RATING
VOLTAGE
NO
LOAD
TORK 60
EWZ SERIES
PREFERRED FOR
OUTDOOR LIGHTING
MULTIPURPOSE CONTROL
1 OR 2 CHANNEL, ASTRONOMIC
7 DAY TIME SWITCH
SPECIFICATIONS
CONTACT RATINGS
TIMING ACCURACY: Line Frequency.
TYPE
INPUT VOLTAGE:
120 - 277VAC, 50/60Hz (automatic detection).
energy
APPLICATIONS
ASHRAE 90.1
Outdoor signs
Lighting security
Heating and air conditioning
40A
120-277 VAC
30A
30A
Inductive
120-277VAC
40A
120-277 VAC
30A
30A
Ballast
120VAC
208-277VAC
30A
20A
120VAC
208-277VAC
30A
20A
10A
10A
POWER CONSUMPTION: 6VA Max.
Tungsten
120VAC
15A
120VAC
15A
2A
ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R
Pilot Duty
120-277VAC
720VA
120-277 VAC
720VA
720VA
Motor
120VAC
208VAC
240-277VAC
1HPTIMER
SUPPLY
11⁄2HP
2HP
SPST
120VAC
208VAC
240-277VAC
1HP
11⁄2HP
2HP
1HP
11⁄2HP
2HP
Resistive
28VDC
28 VDC
30A
30A
is standard with lockable hasp (see page 153 forEWZ120
EWZ101
SPST
enclosure
dimensions).
Suffix -MB without enclosure
TIMER
and includes mounting bracket.
SUPPLY
SPDT
TIMER
SUPPLY
1
2
3
4
1
2
3
LOAD
4
LOAD
5
LOAD
L
N
N
120/277VAC
L
WIRING DIAGRAMS120/277VAC
SCHEDULING: 20 ON & OFF set points
for individual programs for each day of the
week. Minimum setting is 1 minute.
ASTRONOMIC: Adjustable 10° - 60°
Northern or Southern latitudes. Can be
individually offset +/- 1-240 minutes
from both sunset and sunrise times.
DAYLIGHT SAVING: Automatic
(can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
CATALOG
NO.
UPC
CODE
INPUT SUPPLY
(VAC) 50/60Hz
1
NO. OF
CHANNELS
82470
120-277
1
SPST
EWZ103
82473
120-277
1
DPST
EWZ120
82471
120-277
1
SPDT
EWZ201
82472
120-277
2
SPST
120-277
1
82269
120-277
1
DPST
EWZ120-MB
82275
120-277
1
SPDT
EWZ201-MB
82281
120-277
2
SPST
TIMER
SUPPLY
2
1
3
SPST
EWZ103-MB
SPST
2
1
L
N
CH 2
SPST
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides 4 days
of real time backup.
MOMENTARY OPTION: For mechanically held
contactors: Model EWZ201 only. Configure
with simple jumper change for single-channel
momentary operation.
momentary configuration
CH 1
TIMER
SUPPLY
TORK 61
3
4
LOAD
PULSE OFF
1
N
L1
5
2
3
4
5
2
3
TIMER
SUPPLY
L
N
PULSE ON
L
N
CH 2
SPST
LOAD
N
N
DPST
EWZ103
4
5
6
4
5
L2
1
2
4
3
LOAD
CH 1
TIMER
SUPPLY
DPST
5
1
2
LOAD
L
N
3
N
N
L
4
5
6
6
120/277VAC
L
N
N
PULSE ON
PULSE OFF
EWZ201 ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
120/277VAC
DPST
TIMER
SUPPLY
1
2
3
4
5
6
6
L1
L2
4
3
5
6
1
2
SPECIFICATION
WRITER’S
GUIDE
LOAD
208 OR 240VAC
EWZ SERIES – 1. Furnish
and
install
TORK
digital
time
switch
with
(40
AMP
contacts,
models
EWZ101,
EWZ201)
(40 Amp DPST contacts, model EWZ103) (30 AMP
PULSE ON
PULSE OFF
LOAD
LOAD
L
N
contacts,
model
EWZ120). 2. Unit shall be capable of 20 set points. 3. Unit shall be capable of a different schedule for each day of the week. 4. Unit shall be have
120/277VAC EWZ201 ONLY: UNIT MUST BE
CONFIGURED
FOR1°MOMENTARY
OPTION
astronomic option adjustable
from
60° northern
or southern
latitudes. 5. Unit shall be have astronomic option with offset up to 4 hours and 59 minutes, before or
L
N
N
L
N
after sunrise. 6. (Model
EWZ201 ONLY) Unit shall be capable of being a 2 channel maintained or a 1 channel momentary. 7. Unit shall have automatic Daylight Savings
120/277VAC
Time and Leap Year compensation. 8. Unit shall
program in AM/PM format. 9. Display shall be of LCD type. 10. Unit shall have permanent schedule retention. 11. Unit
DPST
TIMER
real time clock shall beSUPPLY
retained by capacitor for 100 hours in a power failure. 12. Unit shall be capable of manual override ON or OFF either in the next scheduled event
or permanently. 13. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 14. Unit shall have Load Status indication. 15. Unit shall have Power Failure
indication. 16. To order1specify
4
3 Model EWZ101
5 (EWZ103)
6 (EWZ120) (EWZ201).
2 TORK
6
L2
PULSE OFF
EWZ201 ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
TI
SU
1
L
5
LOAD
DPST
208 OR 240VAC
120/277VAC
3
208 OR 240VAC
CH 1
EWZ103
L1
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
LOAD
N
TIMER
SUPPLY
1
2
6
LOAD
TIMER
SUPPLY
momentary configuration
CH 1
SPST
N
5
4
EW
120
CH 1
SPST
6
2
N
momentary configuration
CH 2
SPST
SPST
120/277VAC
EWZ201
4
LOAD
LOAD
N
1
EWZ201 ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
L
120/277VAC
3
TIMER
SUPPLY
SPDT
CH 1
PULSE ON
N
120/277VAC
N
CLOCK FORMAT: AM/PM.
DIGITAL
CONTROLS
3
2
L
N
120/277VAC
EWZ120
TIMER
SUPPLY
4
5
N
EWZ201
120/277VAC
EWZ201
3
L
4
LOAD
DPST
SPDT
CH 1
4
LOAD
L
2
1
L
N
momentary configuration
TIMER
SUPPLY
3
SUPPLY
1
4
N
2
120/277VAC
TIMER
TIMER
SUPPLY
120/277VAC
EWZ101
1
30A
N
LOAD
L
1
82263
3
OUTPUT
DRY CONTACTS
EWZ101
EWZ101-MB
2
EWZ101
EWZ120
EWZ103
SPST
CH 2
SPST
CH
1
TIMER
SPST
SUPPLY
ORDERING INFO
N
N
EWZ101
EWZ201
FEATURES
RATING
NO
NC
120-277VAC
OPERATING TEMPERATURE:
-40° to +149° (-40° to +65°C).
CALIFORNIA Title 24
EWZ120
VOLTAGE
General Purpose
TERMINAL RANGE: #8 - #16AWG.
responsible
EWZ101,EWZ103, EWZ201
RATING
VOLTAGE
NO
LOAD
TORK 62
DG100 SERIES
MULTIPURPOSE CONTROLS
1 OR 2 CHANNEL
365/7 DAY
TIME SWITCH
HOLIDAY PROGRAMMING
FOR MORE SAVINGS!
NEW!
SPECIFICATIONS
CONTACT RATINGS
TIMING ACCURACY: Line Frequency.
TYPE
VOLTAGE
NO
NC
Resistive
24-277VAC
20A
10A
Ballast
120 VAC
277 VAC
20A
10A
Tungsten
120VAC
15A
INPUT VOLTAGE:
120 - 277VAC, 50/60Hz (automatic detection).
TERMINAL RANGE: #12 - #18AWG.
APPLICATIONS
OPERATING TEMPERATURE:
-31° to +131°F (-35° to +55°C).
CALIFORNIA Title 24
Pilot Duty
POWER CONSUMPTION: 6VA Max.
ASHRAE 90.1
Indoor/Outdoor lighting
HVAC equipment
School warning and other
Traffic lights
Water heaters in offices,
churches and factories
Motor
ENCLOSURE: Noryl® Indoor/Outdoor NEMA
3R. Suffix -Y metal indoor enclosure NEMA 1. All
with lockable hasp (see page 153 for enclosure
Resistive
120VAC
240VAC
120VAC
240VAC
28VDC
RATING
1HP
2HP
290VA
360VA
1⁄4HP
1⁄2HP
20A
10A
720VA
dimensions).
WIRING DIAGRAMS
DGM100A
DG200A
ORDERING INFO
CATALOG
NO.
UPC
CODE
INPUT SUPPLY
(VAC) 50/60Hz
NO. OF
CHANNELS
OUTPUT
CONTACTS
SCHEDULING: 56 ON & OFF set points
provide individual programs for each day of
the week. Minimum setting is 1 minute.
DG100A
82201
120-277VAC
1
DPDT
DG200A
82209
120-277VAC
2
SPDT
MOMENTARY CONTACT: DGM100A has 2
second contact closures for ON & OFF control of
mechanically held contactors or latching relays.
DGM100A
82210
120-277VAC
1
DGM100A-Y
82222
120-277VAC
1
SPDT
Momentary
SPDT
Momentary
FEATURES
BLOCK HOLIDAY: 9 holiday blocks can be
set for individual days or for duration of any
number of days.
DG100A
DAYLIGHT SAVING: Automatic
adjustment (can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
CLOCK FORMAT: AM/PM or 24 Hour
format.
SPECIFICATION WRITER’S GUIDE
DG100/200A SERIES – 1. Furnish and install, where noted, a 1 (2) channel 7-day programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or
Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast loads at 277VAC. 4. Controller shall be capable fo 56 set points; separate scheduling for
each day of the week with one minute resolution. 5. Controller shall have 365 day holiday capabilities with 9 block holidays for individual or duration of any number of
days. 6. Controller shall be able to select USA Standard Daylight Saving, Standard time, or programmable dates. 7. Controller shall have automatic Leap Year correction.
8. Controller shall have Permanent Schedule Retention. 9. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 10.
Controller shall be capable of Manual Override ON or OFF to the next scheduled event using 1 button for each channel. 11. Unit shall have NEMA Type 3R indoor/outdoor
enclosure as standard. 12. To order specify TORK Model DG100A (DG200A). 13. To order momentary contact closure for latching contactor control specify DGM100A.
POWER OUTAGE BACKUP: Permanent
schedule retention is provided. Supercapacitor
provides 7 days of real time back up.
DIGITAL
CONTROLS
TORK 63
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 64
DZM200B
DZS SERIES
REMOVABLE MEMORY
MODULE FOR COMPUTER
PROGRAMMING!
MULTIPURPOSE CONTROLS
1, 2 OR 4 CHANNEL
365 / 7 DAY ADVANCED
TIME SWITCH
SPECIFICATIONS
N
GND NO
UPPER
BOARD
TIMER SUPPLY
C
ON
L
energy
APPLICATIONS
CALIFORNIA Title 24
HVAC equipment
Horns and bells
Interior lighting
Electric motors
Outdoor lighting
and signs
N
PULSE
ON
208-240V
INPUT VOLTAGE: 120/208-240/277VAC,
50/60Hz.
277V
N
SCHEDULING: 99 ON & OFF set points
allow individual programs for each day of
the week at a minimum 1 minute apart.
NO. OF
CHANNELS
DRY CONTACTS
(UNPOWERED)
DZS100BP
82182
120/208-240/277
1
DPDT
DZS200BP
ASTRONOMIC: Adjustable 10˚ - 60˚ Northern or
Southern latitudes can be individually offset +/-1 to
240 minutes from both sunset and sunrise times.
DZS400BP
USB-MMP
82183
82184
120/208-240/277
120/208-240/277
2
120
4
Memory Module
Programmer
82196
SPDT
82215
120/208-240/277
1
DPDT
HOLIDAYS: 1 to 24 individual dates.
DZS200BP-0
82227
120/208-240/277
2
SPDT
SIGNAL/PULSE DURATION: 2 different
settings per channel: 1-99 seconds.
DZS200BP-12
82228
12VDC
2
SPDT
DZS200BP-24
82229
24VAC
2
SPDT
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation.
82230
120/208-240/277
4
SPDT
NC
24-277VAC
30A
30A
24-277VAC
20A
Ballast
120VAC
277VAC
30A
20A
10A
10A
120-277VAC
13A
Tungsten
120-277VAC
15A
2A
NO C
NC
L
L
LOAD
N
277V
GND NO
Motor Load
C
NC
NO
C
C
N
120 208-240
120-277VAC
Resistive
28VDC120V
N
720VA
120 208-240277
30A
L
ON
OFF
C
12-277VAC
30A
1HP
ON
PULSE
OFF
OFF
720VA 720VA
PULSE
ON
PULSE
OFF
N
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
1HP
L
PULSE
ON
208-240V
8A
CH 2
120-277VAC
720VA
20A
N
MECHANICALLY HELD CONTACTORS
OR LATCHING RELAYS
LOAD
NO
NC
N
277
CH 1
SPDT
L
208-240V
C
TIMER SUPPLY
Pilot Duty
120VAC
CH 1
1HP
2HP
277V
L
LOADNC
NO
1HP
2HP
208-277VAC
NC
CH 2
SPDT
L
WIRING DIAGRAMS
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
CH 4
SPDT
CH 1
SPDT
C
120VAC
DZM200B
N
120V
CH 2
SPDT
L
LOAD
277V
LOAD
N
NO C
TIMER SUPPLY
LOWER
BOARD
N
NC
NO C
NC
DPDT
N
120
208-240 277
L
120V
C
208-240V
SUPPLY
AC LINE INPUT TIMER
SELECT PROPER TERMINALS
277V
AND APPLY ONLY ONE VOLTAGE
DZS100BP
120
L
LOAD
N
NO NC
C
CH 3
SPDT
LOAD
N
NO NC
208-240 277
UPPER
BOARD
120V
L
208-240V
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
L
LOAD
277V
LOAD
N
CH 1
SPDT
C
TIMER SUPPLY
DZS200BP
120 208-240
C
C
NO NC
TIMER SUPPLY
LOAD
277V
MANUAL OVERRIDE: Until the next regularly
scheduled ON or OFF, automatic operation then
resumes. In signal mode, activates pulse.
LOAD
N
N
NC
N
NO C
CH 2
SPDT
NC
NO C
NC
LOWER
BOARD
120
208-240 277
L
120V
L
C
L
CH 1
SPDT
N
L
NO
LOAD
N
277
208-240V
NC
L
CH 2
SPDT
NO NC
CH 4
SPDT
LOAD
120V
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
GND NO
N
DZS400BP
N
DZS400BP-0
General Purpose
PULSE
OFF
CH 2
SPDT
N
LOAD
UPPER
BOARD
Includes software
DZS100BP-0
N
CH 3
SPDT
N
SEASONS: 1 to 4 with different daily schedules
which can wrap around into the new year.
DZS400BP
RATING
VOLTAGE
NO
NC
208-240 277
208-240V
N
SPDT
PULSE
ON
NO C
TIMER SUPPLY
TIMER SUPPLY
(VAC) 50/60Hz
DZS100BP, DZS200BP
RATING
VOLTAGE
NO
NC
TYPE
MECHANICALLY HELD CONTACTORS
OR LATCHING RELAYS
ENCLOSURE: Noryl Indoor/Outdoor NEMA
3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All
with lockable hasp (see page 153 for enclosure
dimensions). DZS400BP
DZS200BP
UPC
CODE
CONTACT RATINGS
LOAD
120V
®
CATALOG
NO.
NC
L
CH 1
SPDT
POWER CONSUMPTION:
5VA Max: DZS100/200BP.
6VA Max: DZS400BP.
FEATURES
OFF
LOWER
BOARD
OPERATING TEMPERATURE:
-40° to +158°F (-40° to 70°C).
ORDERING INFO
C
ON
PULSE
OFF
N
TIMER SUPPLY
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
ASHRAE 90.1
NO
C
LOADL
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
responsible
NC
L
120 208-240277
120V
DZS400BP
TIMING ACCURACY:
Line frequency.
TERMINAL RANGE:
#14-#16AWG for line input.
#12-#16AWG load outputs.
C
OFF
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
LOAD
208-240V
N
277V
L
LOAD
N
DPDT
TIMER SUPPLY
DZS100BP
CLOCK FORMAT: AM/PM or Military time.
POWER OUTAGE BACKUP: Permanent schedule
retention with memory module. Supercapacitor
provides 7 days of real time backup.
C
NO NC
C
NO NC
SPECIFICATION WRITER’S GUIDE
CH 1
CH 2
L
DZS SERIES – 1. Furnish and install, where noted, a 4L (2) (1)LOAD
channel
digital
time switch with portable Memory Module on front panel.SPDT
2. MemorySPDT
Module shall be
LOAD
capable of being programmed at any one location and inserted
into DZS100BP,
200BP, 400BP Series (with memory module socket) in any other remote location.
N
N
C
NO
C NO
NC
3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication
of NC
Memory
Modules
or
DZS200BP
individualized programs for multiple locations 4. Unit shall have copy feature: Can be configured to copy program schedules from one memory module to another
without use of the optional memory module programmer. 5. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 6. Controller shall program in
L
one minute resolution. 7. Display shall be of LCD type. 8. Controller shall be capable of 99 set points; separate scheduling for each
day ofLOAD
theL week. LOAD
9. Controller shall
N
N
have 365 day holiday capabilities with 24 single dates and 4 seasons of unlimited duration. 10. Different daily schedules shall be programmable within
each season.
11. Controller shall have Daylight Saving or Standard time. 12. Controller shall have automatic Leap Year correction. 13. Controller shall haveDPDT
Permanent Schedule
Retention. 14. Controller shall have 7 day backup for real time with built in super capacitor. 15. Controller shall be capable of manual override ON or OFF to the next
Scheduled event using 1 button for each channel. 16. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 17. Controller
shall
C
NO
NC beC capable
NO NCof having
2 different pulse durations 1-99 seconds, user settable and assignable to each channel. DZS100BP
18. Controller shall be capable of having astronomic on one (or all) channels
with 1-240 minutes, plus or minus offset from Sunrise or Sunset. 19. Controller shall be capable of being configured to copy to multiple memory modules. 20. To order
L
L
specify TORK Model DZS100BP (DZS200BP) (DZS400BP).
LOAD
LOAD
N
120
208-240 277
120V
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
208-240V
277V
TIMER SUPPLY
MEMORY MODULE: Removable MM can be
programmed at any one location and inserted into
another DZS series unit.
N
COPY FEATURE: Unit can be configured to copy
program schedule to multiple memory modules.
OPTION: Memory Module Programmer with
software for computer connection programming. Also
allows stand alone battery operation for portable
copy feature.
TORK 65
277
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
208-240V
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
277V
TIMER SUPPLY
N
120
208-240 277
120V
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DIGITAL
CONTROLS
120 208-240
120V
208-240V
277V
N
N
TORK 66
L
DTS SERIES
MAINTAINED AND
SIGNAL TIMING
MULTIPURPOSE CONTROLS
1, 2 OR 4 CHANNEL
365 / 7 DAY ADVANCE
TIME SWITCH
DTS400B
SPECIFICATIONS
Indoor and outdoor lighting
Heating and air conditioning
Security systems
Horns and bells
Low voltage lighting
Misting and spraying
Roof cooling
Clock correction systems
Process functions
CH 2
SPDT
NO C
TIMER SUPPLY
N
120
NC
LOAD
POWER CONSUMPTION: 6VA Max.
UPPER
GND NO
ENCLOSURE: Noryl® Indoor/Outdoor NEMABOARD
3R with lockable hasp (see page 153 for enclosure
dimensions).
CH 1
SPDT
NO
L
DTS400B
N
120
13A
15A
2A
120VAC
8A
120-277VAC
Pilot Duty
120-277VAC
Motor Load
120VAC
208-277VAC
1HP
2HP
1HP
2HP
28VDC
30A
30A
C
NC
Resistive
720VA 720VA
12-277VAC
720VA 720VA
120-277VAC
1HP
1HP
L
N
NO NC
C
NO NC
CH 1
SPDT
WIRING DIAGRAMS
120-277VAC
20A
LOAD
N
C
TIMER SUPPLY
DTS200B
10A
10A
Tungsten
CH 2
SPDT
LOAD
30A
20A
120VAC
277VAC
CH 4
SPDT
NC
20A
Ballast
LOAD
C
24-277VAC
30A
N
CH 3
SPDT
30A
24-277VAC
L
N
277V
RATING
NO NC
General
NC Purpose
NO C
L
208-240V
DTS400B
VOLTAGE
VOLTAGE
208-240 277
120V
DTS100B, DTS200B
RATING
NO
NC
TYPE
TIMING ACCURACY: Line Frequency.
OPERATING TEMPERATURE:
-40° to +149° (-40° to +65°C).
ASHRAE 90.1
CONTACT RATINGS
N
CH 1
SPDT
TERMINAL RANGE:
AC LINE INPUT
#14 - #16AWG for lineSELECT
input.
PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
#12 - #16AWG load outputs.
CALIFORNIA Title 24
LOAD
N
INPUT VOLTAGE: 120/208-277VAC,
LOWER
50/60Hz.
BOARD
APPLICATIONS
L
LOAD
CH 2
SPDT
208-240 277
120V
208-240V
TIMER SUPPLY
AC LINE INPUT
SELECT PROPER TERMINALS
LOWER
AND APPLY ONLY ONE VOLTAGE
L
NO C
BOARD
N
120
ORDERING INFO
FEATURES
SCHEDULING: 99 ON/OFF set points
allow individual programs for each day
of the week at a minimum 1 minute apart.
SEASONS: 1 to 4 with different daily
schedules which can wrap around into the new
year.
CATALOG
NO.
UPC
CODE
TIMER SUPPLY
(VAC) 50/60Hz
DTS100B
NO. OF
CHANNELS
DRY CONTACTS
(UNPOWERED)
DTS100B
82185
120/208-240/277
1
DPDT
DTS200B
82186
120/208-240/277
2
SPDT
DTS400B
82187
120/208-240/277
4
SPDT
LOAD
DPDT
L
LOAD
C
NC
L
LOAD
N
277V
TIMER SUPPLY
120
NO C
N
208-240 277
208-240V
N
NC
N
120V
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
L
LOAD
277V
CH 3
SPDT
N
NO NC
C
NO NC
UPPER
BOARD
208-240 277
120V
C
TIMER SUPPLY
N
CH 1
SPDT
CH 2
SPDT
NO NC
C
120
NO
C
DTS400B
LOAD
N
N
CH 1
SPDT
NO NC
CH 2
SPDT
NO C
TIMER SUPPLY
NC
L
LOAD
N
208-240 277
120
NC
NO C
NC
208-240 277
L
120V
208-240V
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
L
L
LOAD
277V
LOAD
N
N
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
L
LOAD
208-240V
LOAD
N
277V
N
DPDT
N
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes. In signal mode,
activates pulse.
C
TIMER SUPPLY
DTS100B
LEAP YEAR: Automatic Compensation.
120
NO NC
C
NO NC
208-240 277
CH 1
SPDT
120V
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
208-240V
L
L
LOAD
CH 2
SPDT
LOAD
N
N
SPECIFICATION WRITER’S GUIDE
C
NO NC C NO NC
DTS SERIES – 1. Furnish and install, where noted, a 4 (2) (1) channel digital time switch.DTS200B
2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats.
3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each
L
day of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates and 4 seasonsACofLINEunlimited
duration. 7. Different
dailyL schedules shall be
INPUT
LOAD
LOAD
SELECT PROPER TERMINALS
programmable within each season. 8. Controller shall have Daylight Saving or Standard time.
9.APPLY
Controller
have automatic Leap Year Ncorrection.
10.
Controller shall
AND
ONLY ONEshall
VOLTAGE
N
have Permanent Schedule Retention. 11. Controller shall have 7 day backup for real time with built in super capacitor. 12. Controller shall be capable
of
manual
override
DPDT
ON to activate pulse #1 duration. 13. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure as standard. 14. Controller shall be capable of having two different pulse
durations 1-99 seconds, user settable and assignable to each channel. 15. To order specify TORK Model DTS100B (200B) (400B).
277V
TIMER SUPPLY
N
CLOCK FORMAT: AM/PM or Military time.
120
208-240 277
120V
208-240V
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides
7 days of real time back up.
277V
C
TIMER SUPPLY
DTS100B
N
TORK 67
NC
L
LOAD
N
120V
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
DIGITAL
CONTROLS
C
LOWER
BOARD
N
SIGNAL/PULSE DURATION: 2 different
settings per channel: each 1-99 seconds.
GND NO
L
LOAD
277V
DTS200B
HOLIDAYS: 1 to 24 individual dates.
L
208-240V
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
CH 4
SPDT
120
NO NC
C
NO NC
208-240 277
120V
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
208-240V
277V
L
L
LOAD
N
LOAD
N
TORK 68
DW SERIES
SPECIFICATION
FAVORITE!
MULTIPURPOSE CONTROLS
365 / 7 DAY ADVANCED
1 OR 2 CHANNEL TIME
SWITCHES
CONTACT RATINGS
SPECIFICATIONS
VOLTAGE
General Purpose
NC
24-277VAC
30A
30A
Ballast
120VAC
277VAC
30A
20A
10A
10A
Tungsten
120-277VAC
15A
2A
Pilot Duty
120-277VAC
720VA
720VA
Motor Load
120VAC
208-277VAC
1HP
2HP
1HP
2HP
Resistive
28VDC
30A
30A
TERMINAL RANGE:
#14 - #16AWG for line input.
#12 - #16AWG load outputs.
OPERATING TEMPERATURE:
-40° to +158°(-40° to 70°C).
1 CHANNEL
Outdoor lighting
Security lighting
Parking lot lighting
Canopy lighting
RATING
NO
TIMING ACCURACY: Line Frequency.
INPUT VOLTAGE:
120/208-240-277VAC, 50/60Hz.
APPLICATIONS
POWER CONSUMPTION: 5VA Max.
ENCLOSURE: Noryl Indoor/Outdoor
NEMA 3R. Suffix -0 metal Indoor/Outdoor NEMA
3. All with lockable hasp (see page 153 for
enclosure dimensions).
®
2 CHANNEL
HVAC equipment
Interior lighting
Electric motors
Refrigerator defrost control:
condensers, heaters.
WIRING DIAGRAMS
DWZ100B
DWZ100B
SERIES SERIES
ORDERING INFO
CATALOG
NO.
UPC
CODE
TIMER SUPPLY
(VAC) 50/60Hz
NO. OF
CHANNELS
DRY CONTACTS
(UNPOWERED)
SCHEDULING: 99 ON & OFF set points
allow individual programs for each day
of the week at a minimum 1 minute apart.
DWZ100B
82189
120/208-240/277VAC
1
SPDT
DW200B
82190
120/208-240/277VAC
2
SPDT
ASTRONOMIC (DWZ100B only):
Adjustable 10°- 60° Northern or Southern
latitudes. Can be individually offset +/- 1 to 240
minutes from both sunset and sunrise times.
DW200B-0
FEATURES
TYPE
82231
120/208-240/277VAC
2
SPDT
TIMER SUPPLY
TIMER SUPPLY
N
120
120V
N
208-240
120277
208-240
L
120V
277
SPDT
TIMER SUPPLY
TIMER SUPPLYC
N
L
N
277V
AC LINE INPUT
AC LINE INPUT
SELECT PROPER
SELECTTERMINALS
PROPER TERMINALS
AND
APPLY
ONE VOLTAGE
AND APPLY
ONLY
ONEONLY
VOLTAGE
LOAD
N
CH 1 CH 2
SPDT SPDT
CH 2
SPDT
DW200B
DW200B
SERIES SERIES
NO CNC NO NC
LOAD
208-240V208-240V
277V
C
SPDT
CH 1
SPDT
120
120V
N
208-240
120277
208-240
120V
L
208-240V208-240V
277V
277V
NO CNC NO
C NC
NO CNC NO NC
277
L
LOAD
N
L
L
LOAD LOAD
N
N
LOAD
N
AC LINE INPUT
AC LINE INPUT
SELECT PROPER
SELECTTERMINALS
PROPER TERMINALS
AND APPLY
AND
ONLY
APPLY
ONEONLY
VOLTAGE
ONE VOLTAGE
HOLIDAYS: 1 to 24 individual dates.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
TWO SPEED
TWOPUMP
SPEEDWIRING
PUMP WIRING
LEAP YEAR: Automatic Compensation
scheduled ON or OFF, automatic operation then
resumes.
SPECIFICATION WRITER’S GUIDE
DWZ100B – 1. Furnish and install, where noted, a 1 channel digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats.
3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each day
of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates. 7. Controller shall have Daylight Saving or Standard time. 8. Controller shall have
automatic Leap Year correction. 9. Controller shall have Permanent Schedule Retention. 10. Controller shall have 7 day backup for real time with built in supercapacitor.
11. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button. 12. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure
as standard. 13. Controller shall be capable of having astronomic with 1-240 minutes, plus or minus offset from sunrise or sunset. 14. To order specify TORK Model
DWZ100B.
DW200B – 1. Furnish and install, where noted, a 2 channel digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats.
3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each day
of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates. 7. Controller shall have Daylight Saving or Standard time. 8. Controller shall have
automatic Leap Year correction. 9. Controller shall have Permanent Schedule Retention. 10. Controller shall have 7 day backup for real time with built in supercapacitor.
11. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button. 12. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
CLOCK FORMAT: AM/PM or Military time.
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides 7
days of real time backup.
DIGITAL
CONTROLS
TORK 69
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 70
DZM SERIES
GREAT FOR LATCHING
CONTACTORS
MOMENTARY OUTPUT
365 / 7 DAY ADVANCED
LIGHTING CONTROL TIME
SWITCH
APPLICATIONS
CALIFORNIA Title 24
Low voltage latching relays
Direct wire to mechanically
held contactors
General Purpose
120-277VAC
20A
Pilot Duty
120-277VAC
720VA
POWER CONSUMPTION: 4VA Max.
ENCLOSURE: Noryl® Indoor/Outdoor NEMA
3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All
with lockable hasp (see page 153 for dimensions).
FEATURES
SEASONS: 1 to 4 with different daily
schedules which can wrap around into the new
year.
RATING
OPERATING TEMPERATURE:
-40˚ to 158˚F (-40˚ to +70˚C).
ASHRAE 90.1
ASTRONOMIC: Adjustable 10° - 60° Northern
or Southern latitudes can be individually offset
+/- 1 to 240 minutes from both sunset and
sunrise times.
VOLTAGE
TERMINAL RANGE:
#14 - #16AWG for line input.
#12 - #16AWG load outputs.
energy
WIRING DIAGRAMS
ORDERING INFO
CATALOG
NO.
UPC
CODE
TIMER SUPPLY
(VAC) 50/60Hz
NO. OF
CHANNELS
DZM200BP
82188
120/208-240/277
2
DZM200BP-0
82232
120/208-240/277
2
USB-MMP
82196
Memory Module
Programmer
DRY CONTACTS
(UNPOWERED)
SPDT
Momentary
SPDT
Momentary
TIMER SUPPLY
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
N
120
208-240V
Includes software
277V
CH 1
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
C
ON
CH 2
OFF
C
ON
OFF
MECHANICALLY HELD CONTACTORS
OR LATCHING RELAYS
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
L
L
PULSE
ON
PULSE
OFF
N
CLOCK FORMAT: AM/PM or Military time.
POWER OUTAGE BACKUP: Permanent
scheduled retention with memory module.
Supercapacitor provides 7 days of real time
backup.
PULSE
ON
PULSE
OFF
N
SPECIFICATION WRITER’S GUIDE
DZM 200BP only – 1. Furnish and install, where noted, a 2 channel digital time switch with portable Memory Module on front panel. 2. Memory Module shall be capable
of being programmed at any one location and inserted into DZM200BP (with memory module socket) in any other remote location. 3. Optional programmer shall be
available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication of Memory Modules or individualized programs for multiple
locations 4. Unit shall have copy feature: Can be configured to copy program schedules from one memory module to another without use of the optional memory module
programmer. 5. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 6. Controller shall program in one minute resolution. 7. Display shall be of
LCD type. 8. Controller shall be capable of 99 set points; separate scheduling for each day of the week. 9. Controller shall have 365 day holiday capabilities with 24 single
dates and 4 seasons of unlimited duration. 10. Different daily schedules shall be programmable within each season. 11. Controller shall have Daylight Saving or Standard
time. 12. Controller shall have automatic Leap Year correction. 13. Controller shall have Permanent Schedule Retention. 14. Controller shall have 7 day backup for real
time with built in super capacitor. 15. Controller shall be capable of astronomic function, adjustable from 10 – 60 degrees Northern or Southern latitude. Each zone can
additionally be offset 1 - 240 minutes for both sunset and sunrise. 16. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1
button for each channel. 17. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 18. Controller shall be capable of 2 independent momentary outputs ON and OFF for each channel. 19. To order specify TORK Model DZM200BP.
MEMORY MODULE: Removable MM can be
programmed at any one location and inserted
into another DZM series unit.
COPY FEATURE: Unit can be configured to
copy program schedule to multiple memory
modules.
OPTION: Memory Module Programmer with
software for computer connection programming.
Also allows stand alone battery operation for
portable copy feature.
TORK 71
208-240 277
120V
HOLIDAYS: 1 to 24 individual dates.
DIGITAL
CONTROLS
DZM200BP
TYPE
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE: 120/208-240/277VAC,
50/60Hz.
responsible
SCHEDULING: 99 ON & OFF set points
allow individual programs for each day
of the week at a minimum 1 minute apart.
CONTACT RATINGS
SPECIFICATIONS
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 72
ELC SERIES
ENERGY AND LIGHTING CONTROL
1 & 2 ZONE
LIGHTING CONTROL
TIME SWITCH
THE DO-IT-ALL ENERGY
& LIGHTING CONTROLLER
NEW!
FEATURES
CALIFORNIA Title 24
CATALOG
NO.
UPC
CODE
TIMER SUPPLY
(VAC) 50/60Hz
NO. OF
CHANNELS
OUTPUT
CONTACTS
ELC71PC/120
82517
120
1
DPDT
ELC71PC/208-240
82518
208-240
1
DPDT
ELC71PC/277
82519
277
1
DPDT
ELC72PC/120
82520
120
2
SPDT
ELC72PC/208-240
82521
208-240
2
SPDT
ELC72PC/277
82522
277
2
SPDT
EPC-LC
82233
LCS115M
82082
Accessory Photo
Sensor
Accessory
Momentary Switch
SENSOR EVENT: 32 sensor driven events
allow individual programs for each day of the
week.
BLOCK HOLIDAY: 10 holiday blocks can be
set for individual days or for duration of any
number of days and may use one of 3 holiday
schedules.
MOMENTARY CONTACT: May be configured
for momentary ON/OFF operation to control
latching contactors. The ELC71/72 operates as a
single-channel unit.
DIGITAL
CONTROLS
TORK 73
VOLTAGE
General Purpose
POWER CONSUMPTION: 6VA Maximum.
ORDERING INFO
HOLIDAYS: 26 holidays may be set using 10
individual dates, 10 month type (last Monday
in May), or 6 specific holidays with one of 3
independent holiday schedules.
UNIVERSAL INPUT: 2 inputs may be assigned
to any channel.
SWITCHED INPUT: Accepts input from optional
momentary or maintained switch.
PHOTOSENSOR INPUT: Accepts input from
optional sensor. EPC-LC (indoor/outdoor) has a
range from 0 to 200 foot-candles.
USER DEFINED INPUT: Accepts user supplied
4 – 20 milliamp sensor.
TYPE
OPERATING TEMPERATURE:
-20°F to +140°F (-29°C to + 60°C).
ASHRAE 90.1
SCHEDULING: 128 time based events allow
individual programs for each day of the week at
a minimum 1 minute apart. Event types include
ON, OFF, Duration, or Duty Cycle.
ASTRONOMIC: Adjustable 10° - 70°
Northern or Southern latitudes. Settings can be
offset from both sunset and sunrise times.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE:
#10 - #16AWG for line/load.
#14 - #22AWG universal input.
energy
HVAC equipment
Indoor/Outdoor lighting
Meets indoor/outdoor lighting
energy code requirements
CONTACT RATINGS
INPUT VOLTAGE:
120, 208-240, 277 50/60Hz (model specific).
responsible
APPLICATIONS
SPECIFICATIONS
PULSE/TIME DURATION: 4 different ON
settings from 1 second to 23 hours, 59 minutes,
59 seconds.
DUTY CYCLE: 4 different ON and OFF patterns
from 1 second to 23 hours, 59 minutes, 59
seconds.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation.
REMOTE OVERRIDE: Universal input may
be programmed for timed override from a
momentary or maintained dry contact switch.
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
RATING
NO
NC
120/277VAC
20 A
10 A
Ballast
120VAC
208-277VAC
20A
10A
10A
Tungsten
120-277VAC
5A
Pilot Duty
120-240VAC
470VA
275VA
Motor
120VAC
208-277VAC
1HP
2HP
1⁄4HP
1⁄2HP
ENCLOSURE: Noryl® clear cover Indoor/
Outdoor NEMA 3R with lockable hasp (see page
153 for enclosure dimensions).
WIRING DIAGRAMS
ELC72
ELC71
SPST
MANUAL OVERRIDE: Keyboard button
control until the next regularly scheduled ON or
OFF, automatic operation then resumes.
STAGGERED START: Optional stagger up
time between channels, after a power outage;
selectable from 5 seconds, 15 seconds, 30
seconds, 1 minute, 5 minutes, 10 minutes, and
15 minutes.
CLOCK FORMAT: AM/PM or 24 hour format
POWER OUTAGE BACKUP: Capacitor
provides minimum of 1 week of real time
backup for program and time of day.
SPECIFICATION WRITER’S GUIDE
Installer shall furnish and install Tork ELC71 single-channel (or ELC72, two-channel) electronic time control. The control shall have 24 hour, 7 day, 365 day, or astronomic
capability with 128 events available. It shall also have 4 user-definable durations and duty cycle lengths plus automatic daylight savings time and leap year adjustments.
Control shall have remote override capabilities (timed, toggle or enable type.) Control shall have keyboard override until overridden again or until next event is reached.
It shall be capable of switching loads based on user-definable temperature and light levels with 32 events available. Control shall have momentary (latching relay)
capability and shall have astronomic features plus 30 definable holidays and 6 pre-programmed holidays. Controller shall have 7 day backup for real time with built in
supercapacitor. The digital time display shall be 3⁄4” in height. Clock format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. Wiring terminals
shall have the capability to accommodate #16 to #10 AWG wire. Control shall be housed in NEMA 3R enclosure with clear-view cover and shall be lockable to guard
against vandalism or tampering.
TORK 74
ELC SERIES
ENERGY AND LIGHTING CONTROL
4, 8 & 12 ZONE
LIGHTING CONTROL
TIME SWITCH
THE DO-IT-ALL ENERGY &
LIGHTING CONTROLLER
NEW!
energy
CALIFORNIA Title 24
ASHRAE 90.1
HVAC equipment
Indoor/Outdoor lighting
Meets indoor/outdoor lighting
energy code requirements
FEATURES
UPC
CODE
TIMER SUPPLY
(VAC) 50/60Hz
NO. OF
CHANNELS
OUTPUT
CONTACTS
ELC74*
82523
24/120/208-240/277
4
SPDT
ELC78
82524
24/120/208-240/277
8
SPDT
ELC712
82525
24/120/208-240/277
12
SPDT
EPC-LC
82233
Accessory Photo Sensor
LCS115M
82082
Accessory Momentary Switch
TORK 75
INPUT VOLTAGE:
24/120/208-240/277VAC, 50/60Hz.
General Purpose
RATING
NO
NC
120 - 277VAC
20A
10A
Ballast
120 VAC
208-277 VAC
20A
10A
10A
3A
Tungsten
120-277VAC
5A
Pilot Duty
120-240VAC
470VA
275VA
Motor
120VAC
208-277VAC
1HP
2HP
1⁄4HP
1⁄2HP
WIRING DIAGRAMS
SPST
*Also CSA certified.
BLOCK HOLIDAY: 10 holiday blocks can be
set for individual days or for duration of any
number of days and may use one of 3 holiday
schedules.
DIGITAL
CONTROLS
VOLTAGE
ENCLOSURE: Metal Indoor NEMA 1 with
lockable hasp (see page 153 for dimensions).
CATALOG
NO.
SENSOR EVENT: 32 sensor driven events
allow individual programs for each day of the
week.
MOMENTARY CONTACT: May be configured
for momentary ON/OFF operation to control
latching contactors. The ELC74 operates as a
two channel unit. The ELC78 operates as a four
channel unit. The ELC712 operates as a six
channel unit.
TYPE
OPERATING TEMPERATURE:
-20°F to +140°F (-29°C to + 60°C).
ORDERING INFO
HOLIDAYS: 26 holidays may be set using 10
individual dates, 10 month type (last Monday
in May), or 6 specific holidays with one of 3
independent holiday schedules.
UNIVERSAL INPUT: 8 inputs may be assigned
to any channel. ELC74 includes 4.
SWITCHED INPUT: Accepts input from optional
momentary or maintained switch.
PHOTOSENSOR INPUT: Accepts input from
optional sensor. EPC-LC (indoor/outdoor) has a
range from 0 - 200 foot-candels.
USER DEFINED INPUT: Accepts user supplied
4 – 20 milliamp sensor.
TIMING ACCURACY: Line frequency.
POWER CONSUMPTION: 10VA Maximum.
SCHEDULING: 128 time based events allow
individual programs for each day of the week at
a minimum 1 minute apart. Event types include
ON, OFF, Duration, or Duty Cycle.
ASTRONOMIC: Adjustable 10° - 70°
Northern or Southern latitudes. Settings can be
offset from both sunset and sunrise times.
CONTACT RATINGS
TERMINAL RANGE:
#10 - #16AWG for line input.
#10 - #16AWG for load output.
#14 - #22AWG universal input.
responsible
APPLICATIONS
SPECIFICATIONS
PULSE/TIME DURATION: 4 different ON
settings from 1 second to 23 hours, 59 minutes,
59 seconds.
DUTY CYCLE: 4 different ON and OFF patterns
from 1 second to 23 hours, 59 minutes, 59
seconds.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation.
REMOTE OVERRIDE: Universal input may
be programmed for timed override from a
momentary or maintained dry contact switch.
MANUAL OVERRIDE: Keyboard button
control until the next regularly scheduled ON or
OFF, automatic operation then resumes.
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
STAGGERED START: Optional stagger up
time between channels, after a power outage;
selectable from 5 seconds, 15 seconds, 30
seconds, 1 minute, 5 minutes, 10 minutes, and
15 minutes.
CLOCK FORMAT: AM/PM or 24 hour format.
POWER OUTAGE BACKUP: The program
and time of day are maintained for a minimum
of 2 days by means of a capacitor. After two
days, a lithium battery takes over and provides
a minimum accumulated time of 1 year. The
lithium battery should provide over 10 years of
protection.
COMPUTER INTERFACE: Unit may be
programmed with a PC.
SPECIFICATION WRITER’S GUIDE
Installer shall furnish and install Tork ELC74 four channel (ELC78 eight channel or ELC712 twelve channel) electronic time control. The control shall have 24 hour, 7 day,
365 day or astronomic capability with 128 events available. It shall also have 4 (8) user-definable durations and duty cycle lengths plus automatic daylight saving time
and leap year adjustments. Control shall have remote override capabilities (timed, toggle or enable type). Control shall have keyboard override until overridden again
or until next event is reached. It shall be capable of switching loads based on user-definable temperature and light levels with 32 events available. Control shall have
momentary (latching relay) capability and shall have astronomic features plus 30 definable holidays and 6 pre-programmed holidays. Control shall provide 2 days of
power outage carry-over without a battery. Control shall provide 10 years of power outage protection with a battery. The digital time display shall be 3⁄4” in height. Clock
format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. Control shall be capable of interfacing (sending and receiving data) with a personal
computer. Control shall be housed in a NEMA 1, lockable steel enclosure, to guard against vandalism or tampering.
TORK 76
CONTACT RATINGS
Resistive
TERMINAL RANGE: Relay #12AWG; input
power terminals #14 - #22AWG; TOD/sensor
terminals accept #18 - #22AWG.
responsible
energy
APPLICATIONS
ASHRAE 90.1
Pilot Duty
POWER CONSUMPTION: 5VA Maximum.
NO
NC
120/240VAC
277VAC
120VAC
240/277VAC
20A
12A
20A
6A
10A
120/240/277VAC
5A
120/240VAC
277VAC
10A
3A
3A
LIGHT LEVEL
STAGE 1
470VA
690VA
4
5
6
STAGE 2
3
8
2
9
1
275VA
4
7
POWER
1
10
OTHER MOUNTINGS:
LC200M mechanism only.
For 120 VAC
Operation
NEUT 120V240V 277V
LINE INPUT
N
H
WIRING DIAGRAMS
STAGE 1
C
NO NC
5
6
7
3
8
2
SET
ENCLOSURE: LC200 includes metal Indoor
NEMA 1 with lockable hasp (see page 153 for
dimensions).
EPC1 sensor
supplied with unit.
Use to control two different
outdoor lighting circuits utilizing
one photocell. Sign lighting can
turn ON at one ambient light
level while parking lot lighting
turns ON at a different light
level.
9
10
RUN
STAGE 2
C
NO NC
OUTPUT 1 OUTPUT 2
WHITE
BLACK
LOAD 1
TOD1
C
TOD2
LOAD 2
CATALOG
NO.
UPC
CODE
INPUT SUPPLY
(VAC) 50/60Hz
NO. OF
ZONES
OUTPUT
CONTACTS
PHOTOSENSOR INPUT: EPC1 included.
LC200
82111
120/240/277VAC
2
SPDT
DUAL OUTPUTS: with independent turn-ON
adjustment for Stage1 and Stage 2.
LC200M
120/240/277VAC
2
5
6
STAGE 2
4
7
5
6
8
3
8
9
2
9
1
10
SET
LINE INPUT
10
RUN
H
H
C
NO NC
C
NO NC
OUTPUT 1 OUTPUT 2
RED
BLACK
LOAD 1
STAGE 1
STAGE 2
LOAD 2
SPDT
For 277 VAC
Operation
NEUT 120V240V 277V
LINE INPUT
N
H
C
NO NC
C
OUTPUT 1 OUTPUT 2
WHITE
BLACK
NEUT 120V240V 277V
LINE INPUT
H
H
LINE INPUT
N
H
C
NO NC
C
NO NC
OUTPUT 1 OUTPUT 2
WHITE
ORANGE
LOAD 1
LOAD 2
LOAD 2
For 240 VAC
Operation
NEUT 120V240V 277V
NO NC
LOAD 1
SWITCHED INPUT: Can be used with a time
switch for photocell ON of two different lighting
circuits at different ambient light levels, then
time-of-day OFF.
NEUT 120V240V 277V
7
3
2
1
For 120 VAC
Operation
LIGHT LEVEL ACTIVATION: Turn ON is user
settable from 2 to 100 footcandle; Independent
light level adjustment for each zone. Turn OFF
is a maximum of 2 times turn ON level. Built-in
delay ON of 30 seconds to avoid reaction to
lightning or headlights.
STAGE 1
4
POWER
82113
For 240 VAC
Operation
LIGHT LEVEL
EPC
EPC1
ORDERING INFO
FEATURES
Tungsten
OPERATING TEMPERATURE:
-40°F to +140°F (-40°C to + 60°C).
TOD1
C
TOD2
24 hour convenience stores
Open wall parking structures
Large canopies
Building perimeters
Atriums
Ballast
RATING
VOLTAGE
EPC
TYPE
INPUT VOLTAGE:
120/240/277VAC, 50/60Hz.
TOD1
C
TOD2
SPECIFICATIONS
TOD1
C
TOD2
STAGE LIGHTING
TURN ON LEVEL
LIGHT LEVEL / TIME OF DAY OPTION
2 ZONES LIGHTING CONTROL
TIME SWITCH
EPC1
LC200 SERIES
C
NO NC
C
NO NC
OUTPUT 1 OUTPUT 2
RED
BLACK
LOAD 1
SPECIFICATION WRITER’S
GUIDE
LOAD
2
Furnish and install an electronic light sensor and control with dual outputs for two lighting zones. Each output shall be capable of a different user settable turn
ON light level set For
points277
fromVAC
2 to 100 footcandles. Turn ON to turn OFF ratio shall be 1:2. Controller shall also offer two digital inputs, which can accept a contact
Operation
closure from an independent time switch
or EMS system,
thereby allowing for independent time of day control.
LINE INPUT
OUTPUT 1 OUTPUT 2
NEUT 120V240V 277V
N
H
C
NO NC
C
NO NC
WHITE
ORANGE
LOAD 1
LOAD 2
DIGITAL
CONTROLS
TORK 77
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 78
DGU &
DGLC SERIES
CODE SOLUTION FOR
SMALL PROJECTS
NEW!
LIGHTING CONTROL WITH PHOTO
OR OVERRIDE INPUT, 7 DAY
7 DAY LIGHTING
CONTROL TIME SWITCH
TERMINAL RANGE:
#12 - #18AWG for line/load.
#18 - #26AWG sensor/switch input.
responsible
energy
APPLICATIONS
EXTERIOR LIGHTING
Signage and store windows
Security
Parking lots
FEATURES
ASHRAE 90.1
Model EPC-A supplied
with DGLC-A unit.
CATALOG
NO.
With optional
Timed Override
82211
120-277VAC
1
DPDT
DGUM100A
82212
120-277VAC
1
DGUM100A-Y
82224
120-277VAC
1
SPDT
Momentary
SPDT
Momentary
DGLC100A-NC
82223
120-277VAC
1
DPDT
DGLC200A-NC
82213
120-277VAC
2
SPDT
EPC-A
82112
Accessory Photo
Sensor
SSA200R-24
14015
24VAC/24VDC
TRP-U
82030
120/277VAC
PHOTOSENSOR INPUT: Unique push
button set-up assures accurate operation
with automatic calibration that adjusts for
wire size and distance. EPC-A photo sensor is
included with the DGLC-A and may be ordered
as an option for use with model DGU100A &
DGUM100A.
MOMENTARY CONTACT - DGUM100A:
2 second contact closure ON & OFF to control
mechanically held contactors or latching relays.
DIGITAL
CONTROLS
TORK 79
OUTPUT
CONTACTS
VOLTAGE
Resistive
ENCLOSURE: Noryl® Indoor/Outdoor NEMA
3R . Suffix -NC Noryl® Indoor/Outdoor NEMA
3R with clear Lexan® cover. Suffix -Y metal
Indoor enclosure NEMA 1. All with lockable
hasp (see page 153 for dimensions).
RATING
NO
NC
24-277VAC
20A
10A
Ballast
120VAC
277VAC
20A
10A
Tungsten
120VAC
15A
Motor
POWER CONSUMPTION: 6VA Maximum.
INPUT SUPPLY
NO. OF
(VAC) 50/60 Hz CHANNELS
DGU100A-Y
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
REMOTE OVERRIDE ON: Each channel has
independent input for a maintained dry-contact
closure. May use TORK model SSA200R-24
and TRP-U for timed override. May use with
occupancy sensor as override.
UPC
CODE
TYPE
Pilot Duty
OPERATING TEMPERATURE:
-31°F to +131°F (-35°C to + 55°C).
ORDERING INFO
SCHEDULING: 56 ON & OFF set points
provide individual programs for each day
of the week. Minimum setting is 1 minute.
LIGHT LEVEL ACTIVATION: Turn ON is user
settable from 1 to 100 footcandle; Turn OFF
is a maximum of 2 times turn ON level. Each
channel has an independent setting. Includes a
user settable delay before ON or OFF between
1 – 90 seconds.
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE: 120-277VAC, 50/60Hz
(auto detection).
CALIFORNIA Title 24
INTERIOR LIGHTING
Open office zoning
Hallways
Meeting and sales areas
Stock rooms and warehouses
CONTACT RATINGS
SPECIFICATIONS
Resistive
120VAC
240VAC
120VAC
240VAC
28VDC
DGU100A
1HP
2HP
290VA
360VA
1⁄4HP
1⁄2HP
20A
10A
720VA
DGUM100A
DGU100A
WIRING DIAGRAMS
DGU100A
DGLC100A
DGUM100A
SPDT
Transformer
Power Pack
SPST
DGUM100A
DGLC100A
DGLC200A
BLOCK HOLIDAY: 9 holiday blocks can be
set for individual days or for duration of any
number of days.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation.
CLOCK FORMAT: AM/PM or 24 Hour
format.
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides 7
days of real time backup.
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
DGLC100A
DGLC200A
SPECIFICATION WRITER’S GUIDE
DGU and DGLC SERIES - 1. Furnish and install, where noted, a 1 (2) channel 7 day programmable digital time switch. 2. Controller shall program in AM/PM (12
hour) or Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast load at 277VAC. 4. Controller shall be capable of 56 set points; separate
scheduling for each day of the week with one minute resolution. 5. Controller shall have photo sensor input user adjustable per circuit between 1 and 100 footcandle
turn ON level. 6. Each channel shall have and switched input to override circuit ON. 7. Controller shall have 365 day holiday capabilities with 9 block holidays
for individual or duration of any number of days. 8. Controller shall be able to select USA Standard Daylight Saving, Standard time, or programmable dates. 9.
Controller shall have automatic Leap Year correction. 10. Controller shall have Permanent Schedule Retention. 11. Controller shall have 7 days backup for real time
with built in super capacitor; no batteries to maintain. 12. Controller shall be capable of Manual Override ON and OFF to the next scheduled event using 1 button
for each channel. 13. Unit shall have NEMA type 3R indoor/outdoor enclosure standard. 14. To order specify TORK Model DGU100A. (Alt 14. To order 1 channel
momentary contact closure for latching contactor control specify DGUM100A). (Alt 14. To order controller with EPC-A photo sensor included in package specify TORK
Model DGLC100A-NC (DGLC200A) with clear cover.
TORK 80
DLC400BP
FLEXIBLE INDOOR/
OUTDOOR LIGHTING
CONTROLLER
4 ZONE LIGHTING CONTROL
TIME SWITCH
responsible
energy
APPLICATIONS
INTERIOR LIGHTING
Open office zoning
Hallways
Meeting and sales areas
Stock rooms and warehouses
EXTERIOR LIGHTING
Signage and store windows
Security
Parking lots
FEATURES
CONFIGURABLE ZONES: Simple three
position slide switch sets logic for each zone:
Time ON/Time OFF, Photo ON/Photo OFF, or
Photo ON/ Time OFF.
SCHEDULING: 99 ON & OFF set points allow
individual programs for each day of the week.
Minimum 1 minute apart.
ASTRONOMIC: 1. Adjustable 10° - 60°
Northern or Southern latitudes. 2. Can be
individually offset +/-1-240 minutes from both
sunset and sunrise times.
PHOTOSENSOR INPUT: EPC2 photo sensor
included.
LIGHT LEVEL ACTIVATION: Turn ON
and OFF level is user settable from 1 to 100
footcandle. Each channel has an independent
setting.
REMOTE OVERRIDE: Maintained dry contact
closure or use TORK Model SSA200R-24 for
timed override with flash warning before OFF.
May use with occupancy sensor as override.
DIGITAL
CONTROLS
TORK 81
CALIFORNIA Title 24
SPECIFICATIONS
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE:
120/208 - 240/277VAC, 50/60Hz.
CONTACT RATINGS
TYPE
VOLTAGE
General Purpose 24-277VAC, 30VDC
RATING
NO
NC
30A
30A
10A
TERMINAL RANGE: #10 - #14AWG.
Ballast
120-277VAC
20A
OPERATING TEMPERATURE:
-40°F to +158°F (-40°C to + 55°C).
Tungsten
120VAC
10A
Pilot Duty
120-277VAC
720VA
720VA
POWER CONSUMPTION: 30VA Maximum.
ASHRAE 90.1
ENCLOSURE: Metal Indoor/Outdoor NEMA 3 with
lockable hasp (see page 153 for dimensions).
Model EPC2
supplied with unit.
Memory Module
Programmer optional
WIRING DIAGRAMS
With optional
Timed Override
ORDERING INFO
CATALOG
NO.
UPC
CODE
INPUT SUPPLY (VAC)
50/60 Hz
NO. OF
CHANNELS
OUTPUT
CONTACTS
DLC400BP
82191
120/208-240/277
4
SPDT
USB-MMP
82196
Memory Module
Programmer
SSA200R-24
14015
24VAC/24VDC
Includes Software
SPDT
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
SEASONS: 1 to 4 with different daily schedules
which can wrap around into the new year.
HOLIDAYS: 1 to 24 individual dates.
DAYLIGHT SAVING: Automatic adjustment
(can be omitted).
LEAP YEAR: Automatic Compensation.
POWER OUTAGE BACKUP: Permanent
schedule retention with memory module.
Battery provides real time backup for 6 months
cumulative.
MEMORY MODULE: Removable MM can be
programmed at any one location and inserted
into another DZS series unit.
OPTION: Memory Module Programmer with
software for computer connection programming.
Also allows stand alone battery operation for
portable copy feature.
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
SPECIFICATION WRITER’S GUIDE
DLC400BP – 1. Furnish and install, where noted, a 4 zone lighting controller with photosensor input (TORK model EPC2 photosensor to be supplied with controller). 2. Memory Module shall be capable of being
programmed at any one location and inserted into DLC400BP (with memory module socket) in any other remote location. 3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows
based settings on a PC for easy duplication of Memory Modules or individualized programs for multiple locations 4. Each zone shall be capable of independent, user settable turn ON and turn OFF light level set
points ranging from 1 to 100 footcandles. 5. Three position slide switches shall be provided for each of the 4 zones allowing for user settings based on a) time of day or b) combination time of day and light level or
c) light level. 6. Controller shall provide 30 Amp General Purpose isolated contacts (unpowered) for each zone as well as a 500 ma, 24VDC output. 7. Controller shall have 1 digital input per channel for: a) remote
contact closure which can be used to turn corresponding outputs ON/OFF outside of the normal control time or b) remote timed override which can be accomplished for the corresponding outputs with the use of TORK
model SSA200R-24. 8. Enclosure shall provide separate wiring compartments for power connections and auxiliary connections. 9. Controller shall be capable of local override ON or OFF to the next scheduled event
using the keypad for each zone. 10. Each zone shall be capable of astronomic function, adjustable from 10 – 60 degrees Northern or Southern latitude. Each zone can additionally be offset +/- 1–299 minutes for
both sunset and sunrise. 11. Controller shall provide automatic daylight saving time (which can be omitted). Leap year adjustment shall be compensated for automatically. 12. Controller shall have 365 day holiday
capability with 24 single dates and 4 seasons of unlimited duration. 13. Controller shall be capable of 99 set points with separate scheduling for each day of the week. 14. Controller shall have back-up capability: a)
Schedule shall be retained for 40 years without power, b) real time shall be retained for 6 months using a field replaceable 9V lithium battery. 15. Unit shall have a NEMA type 3, metal indoor/outdoor enclosure.
TORK 82
LD SERIES
ADD A WARNING BLINK
TO ANY CONTROL
EXTENDED LIGHTING CONTROL
LIGHTING DELAY
TIME SWITCH
INPUT VOLTAGE:
120/208/240/277VAC, 50/60Hz.
TERMINAL RANGE: #10 - #16AWG.
OPERATING TEMPERATURE:
-22° to 150°F (-30° to +65°C).
ASHRAE 90.1
APPLICATIONS
CONTACT RATINGS
SPECIFICATIONS
POWER CONSUMPTION: 5VA Maximum.
®
®
ENCLOSURE: Metal Indoor NEMA 1 with
lockable hasp (see page 153 for dimensions).
®
®
Open offices
Gymnasiums
Warehouses
Outdoor recreation courts
User-activated lights
with time limits
Match with photocontrol and
timer to limit hours of use
RATING
TYPE
VOLTAGE
General
Purpose
Ballast
24/240VAC
277VAC
120VAC
208-277VAC
Tungsten
120-277VAC
5A
3A
Pilot Duty
120-240VAC
27VAC
470VA
690VA
275VA
Resistive
28VDC
20A
10A
NO
NC
20A
20A
20A
10A
10A
3A
10A
3A
WIRING DIAGRAMS
LDSH WIRING
LDS WIRING
TORK TIME SWITCH
TORK TIME SWITCH
OUTPUT TERMINALS
OUTPUT TERMINALS
OFF
NO
C
OFF
NC
MOMENTARY
PUSH-BUTTON SWITCH
C ON OFF
DO NOT APPLY
VOLTAGE
N
TIME SWITCH
INPUT
120
208
240
H
REMOTE
INPUT
277
VAC
H
C ON OFF
DO NOT APPLY
INPUT POWER
VOLTAGE
NO
N
N
C
277
VAC
INPUT POWER
AUX. OUTPUT
TERMINALS
NC
208
240
120
TIME SWITCH
INPUT
MAIN LOAD OUTPUT
TERMINALS
NC
120 VAC
ON
ON
N
NC
N
N
H
C
MOMENTARY
PUSH-BUTTON
SWITCH
H
REMOTE
INPUT
NO
MAIN LOAD OUTPUT
TERMINALS
NO
C
NC
NO
C
H
H
H
AUX
LOAD
ORDERING INFO
FEATURES
MAINTAINED INPUT WITH LOAD WARNING BLINK:
LDS Series controls output load contacts based on power applied
to the time switch input contact. At removal of power from
the time switch input, LDS Series provides 1 second blink then
keeps load contacts closed for an extra 1 or 5 minutes (user
selectable) before turn off.
MAINTAINED INPUT WITH AUXILARY WARNING:
LDSH Series controls output load contacts based on power
applied to the time switch input contact. At removal of power
from the time switch input, LDSH Series closes a second set of
contacts for a user supplied audible or visual warning device.
The warning circuit closes for a selected time of 4 seconds (best
for audible device or continuous, then keeps load contacts closed
for an extra 1 or 5 minutes (user selectable) before turn OFF.
CATALOG
NO.
LDS-A
LDS
LDSH-A
LDSH
UPC
CODE
81026
81025
81031
81028
INPUT SUPPLY (VAC)
50/60 Hz
120/208-240/277
120/208-240/277
120/208-240/277
120/208-240/277
MOMENTARY INPUT: Provides timed override when time
switch input contact is unpowered (timer OFF). When activated
during the warning period, load contacts are kept closed and
timing starts. Both series can accept momentary input contact
closure for ON to start the timing and OFF to end the timing.
TIMED OVERRIDE SETTINGS: User may select override
times of 1⁄2, 1, 11⁄2, 2, 6, 9, or 12 hours. Warning before OFF is
always active after override time.
LOAD
OUTPUT
CONTACTS
ENCLOSURE
TYPE
SPDT
Metal Indoor
NEMA 1
SPDT
SPDT
SPDT
Mechanism
Metal Indoor
NEMA 1
Mechanism
N
TORK TIME SWITCH
TORK TIME SWITCH
OUTPUT TERMINALS
OUTPUT TERMINALS
OFF
NO
C
OFF
NC
MOMENTARY
PUSH-BUTTON SWITCH
VOLTAGE
N
TIME SWITCH
INPUT
N
120
208
240
H
120 VAC
REMOTE
INPUT
277
VAC
H
C ON OFF
DO NOT APPLY
INPUT POWER
VOLTAGE
NO
N
N
C
NO
277
VAC
INPUT POWER
AUX. OUTPUT
TERMINALS
NC
208
240
120
TIME SWITCH
INPUT
MAIN LOAD OUTPUT
TERMINALS
NC
NC
ON
ON
H
C
N
N
C ON OFF
DO NOT APPLY
NO
MOMENTARY
PUSH-BUTTON
SWITCH
H
REMOTE
INPUT
N
LOAD
N
MAIN LOAD OUTPUT
TERMINALS
C
NC
NO
C
H
H
H
ON
OFF
COMMON
AUX
LOAD
MECHANICALLY HELD
CONTACTOR WITH
COIL CLEARING
CONTACTS
ON
N
MECHANICALLY HELD
CONTACTOR WITH
COIL CLEARING
CONTACTS
OFF
COMMON
PHOTOCONTROL
N
N
TORK TIME SWITCH
OUTPUT TERMINALS
APPLICATION EXAMPLE
Lighting for a high school’s tennis courts
turns on during normal class hours
when natural light diminishes using a
7 day time switch and photocell. After
3pm, staff members sometimes use the
courts (the time switch is then off). A
momentary pushbutton activates the
LDSH for timed override of HID lighting.
Five minutes before the lights go out, an
auxiliary contact flashes an incandescent
warning beacon (HID lighting can not
be made to blink). Additional timed
override can be arranged for via the
momentary pushbutton.
APPLICATION WIRING
NO
C
NC
FLASHING LIGHT
H
120V
N
C
ON
H
OFF
N
N
120 208/240277
REMOTE INPUT TIME SWITCH INPUT
MOMENTARY
PUSHBUTTON
SWITCH
AUXILLARY
OUTPUT
NO
C
LDSH
NC
INPUT POWER
N
MAIN LOAD
OUTPUT
NO
C
NC
120V
OFF
N
ON
H
120V
N
OFF
SWITCHED CIRCUIT
TO TENNIS COURT
LIGHTS
ON
N
MECHANICALLY-HELD
4 POLE LIGHTING
CONTACTOR
SWITCHED CIRCUIT
TO TENNIS COURT LIGHTS
480V CIRCUITS FROM PANEL
DIGITAL
CONTROLS
TORK 83
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 84
DGS SERIES
SIGNALING AND DUTY CYCLE
24 HOUR OR 7 DAY
TIME SWITCH
31 DAY CYCLE TIME:
AN INDUSTRY FIRST!
NEW!
SPECIFICATIONS
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE:
120 - 277 VAC, 50/60 Hz (auto detection).
TERMINAL RANGE: #12 - #18AWG.
OPERATING TEMPERATURE:
-31°F to +131°F (-35°C to + 55°C).
APPLICATIONS
POWER CONSUMPTION: 6VA Maximum.
Signaling
Duty cycle
ENCLOSURE: Noryl Indoor/Outdoor NEMA
3R with lockable hasp (see page 153 for
enclosure dimensions).
®
CONTACT RATINGS
TYPE
VOLTAGE
Resistive
RATING
NO
NC
24-277VAC
20A
10A
Ballast
120VAC
277VAC
20A
10A
Tungsten
120 VAC
15 A
Motor
120 VAC
240VAC
120VAC
240VAC
Resistive
28VDC
Pilot Duty
720VA
1HP
2HP
20A
290VA
360VA
1⁄4HP
1⁄2HP
DGS100A
FOR 120V/277VAC
10A
WIRING DIAGRAMS
DGS100A
FOR 208-240VAC
DGS100A
FOR 120V/277VAC
DG180A
FOR 120V/277VAC
ORDERING INFO
FEATURES
DG180A & DG280A: 56 ON & OFF set points provide
individual daily programs. Minimum setting is 1 minute.
DGS100A: 56 ON & OFF set points provide individual programs
for each day of the week. Minimum setting is 1 minute.
DUTY CYCLE: Two different ON/OFF patterns or signal
durations may be programmed. The durations can be up to 23
hours, 59 minutes and 59 seconds in length.
SKIP FUNCTION (24 HOUR UNITS ONLY): Each channel
can be set for ACTIVE/SKIP operations that alternate from 1 - 31
days. This becomes an effective way to cycle loads on varying
days within the month. Using the two-circuit DG280A, two loads
can be set to operate on alternate days in a simple manner.
CATALOG
NO.
UPC
CODE
INPUT SUPPLY (VAC)
50/60 Hz
NO. OF
CHANNELS
OUTPUT
CONTACTS
24 HOUR MODELS
DG180A
82206
120-277VAC
1
DPDT
DG280A
82207
120-277VAC
2
SPDT
DG280A-24
82220
24VAC
2
SPDT
120-277VAC
1
DPDT
DGS100A-12 82218
12VDC
1
DPDT
DGS100A-24 82219
24VAC
1
DPDT
DGS100A
FOR 208-240VAC
DG180A
FOR 208-240VAC
DG280A
7 DAY MODELS
DGS100A
82205
DAYLIGHT SAVING: Automatic adjustment (can be omitted).
DG280A
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next regularly scheduled ON
or OFF, automatic operation then resumes.
CLOCK FORMAT: AM/PM or 24 hour.
POWER OUTAGE BACKUP: Permanent schedule retention.
Supercapacitor provides 7 days of real time backup.
DIGITAL
CONTROLS
TORK 85
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
SPECIFICATION WRITER’S GUIDE
DGS100A SERIES –1. Furnish and install, where noted, a 1 channel 7 day programmable digital time switch. (Alt 1 DG180 Series 1. Furnish and install, where noted,
a 1 (2) channel 24 hour programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Unit shall be capable of
switching 20 amps ballast load at 277VAC. 4. Controller shall be capable of 56 set points; separate scheduling for each day of the week with one minute resolution. 5.
unit shall be capable of two duty cycle or signal durations from 1 second to 23 hours, 59 minutes and 59 seconds. 6. Controller shall be able to select USA Standard
Daylight Saving, Standard time or programmable dates. 7. Controller shall have automatic Leap Year correction. 8. Controller shall have Permanent Schedule Retention.
9. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 10. Controller shall be capable of Manual Override ON and OFF
to the next scheduled event using 1 button for each channel. 11. Unit shall have NEMA type 3R indoor/outdoor enclosure as standard. 12. To order specify TORK Model
DGS100A (Alt 12. Controller shall have a 31 day cycle to alternate days that programs are active or to be omitted. 13. To order specify TORK Model DG180A [DG280A]).
TORK 86
EJWT & E500T
SERIES
NEW!
PERFECT FOR
PROCESS CONTROL
DELAY, INTERVAL &
PERCENTAGE TIME CYCLE
TIME SWITCHES
SPECIFICATIONS
CONTACT RATINGS
TIMING ACCURACY: 1% of timing range.
TYPE
VOLTAGE
General Purpose
Resistive
INPUT VOLTAGE: 120/240VAC, 60Hz.
TERMINAL RANGE: #12 - #18AWG.
OPERATING TEMPERATURE:
32°F to +122°F (0°C to + 50°C).
APPLICATIONS
POWER CONSUMPTION: 16VA Maximum.
EJWT
RATING
NO
NC
120-240VAC
20A
10A
120-240VAC
20A
10A
Motor
120VAC
208-240VAC
1HP
2HP
1⁄4HP
Pilot Duty
120/240VAC
470VA
275VA
1⁄2HP
ENCLOSURE: Indoor NEMA 4X is standard (see
page 153 for enclosure dimensions).
Poultry and livestock
Agriculture or greenhouse
Oil well pumping
Ventilation
Process control
E502T
E501T
EJWT
ORDERING INFO
FEATURES
EJWT – PERCENTAGE TIMER
• 960 time combinations with two dials.
• Cycle Time Dial sets 32 repeating cycles from
15 seconds to 24 hours.
• Percentage ON Dial has 32 steps from 0%
to 100%.
• Repeats cycle as long as power is applied.
CATALOG
NO.
UPC
CODE
INPUT SUPPLY (VAC)
60 Hz
OUTPUT
CONTACT
EJWT
82513
120-240VAC
SPDT
E500T
82514
120-240VAC
SPDT
E501T
82515
120-240VAC
SPDT
E502T
82516
120-240VAC
SPDT
E500T – ON DELAY TIMER
• Dial sets 32 time delay durations from
5 seconds to 3 hours.
• External switch activated starts delay to ON.
• Runs until external switch turns OFF.
WIRING DIAGRAMS
EJWT
E500T / E501T / E502T
E501T – AUTO OFF INTERVAL TIMER
• Dial sets 32 time durations from 10 seconds
to 12 hours.
• Start/Stop button or External switch starts
interval ON.
• Automatically turns OFF at end of preset time.
• START/STOP or External switch turns OFF.
E502T – OFF DELAY TIME
• Dial sets 32 time durations from 5 seconds
to 3 hours.
• External switch starts interval ON.
• Automatically turns OFF at end of preset time.
• External switch turns OFF.
DIGITAL
CONTROLS
TORK 87
E500T / E501T / E502T
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 88
DIN SERIES
1 OR 2 CHANNEL
7 DAY TIME SWITCH
ASHRAE 90.1
CONTACT RATINGS
SPECIFICATIONS
PANEL BUILDERS
CHOICE
CALIFORNIA Title 24
NEW!
OPERATING TEMPERATURE:
DIN100B: 14°- 131°F (-10°- +55°C).
DIN200B: 14°- 113°F (-10°- +45°C).
Panel builders
Indoor/Outdoor lighting
Security systems
HVAC equipment
CALIFORNIA Title 24
DIN100B
VOLTAGE
Resistive
POWER CONSUMPTION: 4VA Maximum.
ASHRAE 90.1
RATING
NO
NC
120VAC
16A
16A
General Purpose
120VAC
8A
8A
Motor
(DIN100 only)
120VAC
1⁄2HP
TERMINAL RANGE: #12 - #18AWG.
APPLICATIONS
TYPE
INPUT VOLTAGE: 120VAC, 50/60Hz.
MOUNTING: DIN rail #50022 (35mm) or
flat surface using supplied adapter.
DIN200B
WIRING DIAGRAMS
DIN200B
DIN200B
DIN100B
DIN100B
ORDERING INFO
UPC
CODE
DRY
CONTACTS
CLOCK INPUT
50/60 Hz
NO. OF
CHANNELS
NUMBER OF
ON/OFF
DIN100B
82193
SPDT
120VAC
1
8
2
4 Channel A
3 Channel B
DIN200B
82192
SPDT
120VAC
35.80
Channel B (C2)
Output
55.00
52.5
NC
14
8
7
6
1
2
3
DIN100B
35.80
46.00
60.00
5
6
1
2
NC
NO
2
3
4
5
Input
D
Channel B (C2)
NO
3
1
Channel A (C1)
14
8
7
6
1
2
3
85
85.00
45.00
7
6
60
Channel B (C2)
8
7
35.2
Channel A (C1)
Output
52.5
NC
8
Channel A (C1)
Channel B (C2)
Output
55.00
4
NC
NO
DIN200B
CLOCK FORMAT: AM/PM.
Channel B (C2)
NO
85
MANUAL OVERRIDE: Until the next regular
scheduled ON or OFF, automatic operation then
resumes.
POWER OUTAGE BACKUP: Battery retains
time and schedule.
60
Channel B (C2)
85.00
SCHEDULING: 8 ON and OFF pairs of set
points for DIN100B. 4 ON and OFF (CH A) and
3 ON and OFF (CH B) pairs of set points for
DIN200B. Individual programs on each day of
the week. Minimum setting is 1 minute.
CATALOG
NO.
45.00
FEATURES
4
35.2
5
4
5
Channel A (C1)
Channel A (C1)
46.00
60.00
DIGITAL
CONTROLS
TORK 89
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
Channel A (C1)
Output
Input
TORK 90
SMC SERIES
5401 SERIES
SPECIFICATIONS
MOMENTARY
CONTACT ADAPTER
INCREASED AMPERAGE
& VOLTAGE SWITCHING
40 AMP CONTACTORS
INPUT VOLTAGE: 120VAC, 50/60Hz.
TERMINAL RANGE: #12 - #18AWG.
OPERATING TEMPERATURE:
-31°F to +131°F (-35°C to + 55°C).
POWER CONSUMPTION: 6VA max.
APPLICATIONS
ENCLOSURE: Noryl® Indoor/Outdoor
NEMA 3R with lockable hasp (see page
153 for dimensions).
Converts maintained contacts for
pulse switching
Timer to latching contactor control
Photocell to latching contactor control
Signaling
CONTACT RATINGS
5401
Lighting loads
Exhaust fans
Electric and hot water heaters
Refrigeration and defrosting
5441
TYPE
VOLTAGE
RATING
Resistive
120-600VAC
50A
FLA
120-600VAC
40A
Motor
120VAC
240VAC
480VAC
600VAC
3HP
7.5HP
20HP
25HP
ORDERING INFO
UPC
CODE
INPUT SUPPLY
(VAC) 50/60Hz
OUTPUT
CONTACTS
SMC3D
52011
120
SPDT
Momentary
CONTACT RATINGS
NC
Resistive
120VAC
10A
10A
General Purpose
120VAC
10A
10A
Motor
120VAC
1⁄4HP
NC
SMC 3D
ON RELAY
NC NO C
5401
H
120VAC
N
INPUT
120
VAC
OFF RELAY
BLACK
NC NO C
WHITE
Control circuit
from Time Switch
ON PULSE
120VAC
NEUTRAL
N
L
C
NO
AUX
LOAD
DIGITAL
CONTROLS
TORK 91
LOAD
N
LOAD
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
NC
H
CONTACT
277VAC
480VAC
81021
81022
120VAC
208VAC
277VAC
480VAC
Wire
B, C
the sa
NO. AOF
CONTACTORS
120
1
120
4
OUTPUT
CONTACTS
N
B
3PST
120VAC
208VAC
277VAC
480VAC
Control circuit from Time Switch
24VAC
Wire other circuits B, C and D respectively
120 to 480VAC
{
A
N
C
D
C
D
A
Keep low voltage wires
inside this compartment.
120VAC
208VAC
277VAC
480VAC
B
Wire contactors
B, C and D
the same as A.
D
B
120VAC
208VAC
277VAC
480VAC
Wire other c
3PST
C
A
24VAC
5441
120 to 480VAC
Control circu
B
Control circuit from Time Switch
120VAC
C
D
Keep low voltage wires
inside this compartment.
Wire other circuits B, C and D respectively
120VAC
120
VAC
SMC 3D
ON RELAY
OFF RELAY
NC NO C
NC NO C
PUSH
ON
{
N
120VAC
COIL
VOLTS
{
TORK DIGITAL CONTROL
TERMINAL BLOCK
MAINTAINED CONTACT INPUT
L
5401
{
UPC
120VAC
CODE
208VAC
120VAC
208VAC
277VAC
480VAC
Control circuit
from Time Switch
Wire contactors
B, C and D
the same as A.
H
REALAY CONTACTOR
L
CATALOG
NO.
5441
PUSH OFF
OFF PULSE
120VAC
208VAC
277VAC
480VAC
5
120VAC
208VAC
277VAC
480VAC
120VAC
208VAC
277VAC
480VAC
ORDERING
5440INFO
N
PUSH ON
LOW VOLTAGE
LATCHING RELAY
OR MECHANICALLY
HELD CONTACTOR
WHITE
ENCLOSURE: 5401 - Metal NEMA 3
enclosure. 5441 - Metal NEMA 1 Indoor
enclosure (see page 153 for enclosure
dimensions).
TORK DIGITAL CONTROL
TERMINAL BLOCK
MAINTAINED CONTACT INPUT
NO
BLACK
EASY WIRING: Includes 120 volt control
wiring compartment. 5441 has terminal strip
pre-mounted for quick connection.
SMC 3D
120VAC,
240VAC
Input – Sustained voltage 120VAC
WIRING
DIAGRAMS
277VAC, 30VDC
Momentary Contacts (unpowered)
30 Amps inrush
C
5401
CONTACT RATINGS: Can switch up to 40
AMPS per pole from 120VAC to 600VAC, one
to three circuits simultaneously.
{
NO
{
MOMENTARY OUTPUT: SMC3D provides
two dry output contacts. The ON contact
provides a 2 second contact closure (pulse)
when power is applied to the input contacts.
The OFF contact provides a 2 second pulse
when power is removed from the input
contacts.
RATING
VOLTAGE
WIRING DIAGRAMS
FEATURES
{
TYPE
MAINTAINED INPUT: SMC3D accepts
maintained input power from any 120 volt
control. When power is applied or removed a
short contact closure (pulse) is created on the
dry output contacts.
Coil Data: 120VAC @ 60Hz
6VA Holding/seal; 60VA inrush
{
FEATURES
CATALOG
NO.
{
APPLICATIONS
TORK 92
HPS STARTER
SPECIFICATIONS
FOR HIGH PRESSURE SODIUM LAMPS
STARTING AID
LINE VOLTAGE: 105 - 347VAC.
LAMP VOLTAGE: 55 or 100VAC.
TRP SERIES
SPECIFICATIONS
LOW VOLTAGE SWITCHING
TRANSFORMER RELAY
POWER PACKS
CONTACTS: SPST contacts.
CONTACT RATING:
20 Amps Ballast @ 120 or 277VAC.
15 Amps Tungsten @ 120VAC.
1.0 Horsepower @ 120VAC.
LAMP WATTAGE: 35 to 400 watts.
OPERATING TEMPERATURE:
-40°F to +221°F (-40°C to + 105°C).
APPLICATIONS
LEAD LENGTH: 9 inches.
ENCLOSURE: Durable, high temperature
Designed to operate as a starting aid, for all
H.P.S. ballasts from 35 to 400 watts, with lamp
voltage of 55 or 100 volts.
Lexan® housing.
APPLICATIONS
TEMPERATURE RANGE:
0° to 150°F (–18° to 66°C).
Pre-wired in metal enclosure.
Low voltage switching of line voltage
lighting circuits up to 20 Amp ballasts or
15 amp tungsten loads. Also up to 1.0 HP
motors for ventilating and exhaust fans.
Low voltage switching by digital or
mechanical controls for higher amperage
loads including those of two different
voltages.
ORDERING INFO
FEATURES
SMART VOLTAGE: Delivers appropriate
trigger spikes for lamp ignition, then reduces
voltage to good lamps. Continues to feed
voltage spikes to old or poorly working
lamps.
CATALOG
NO.
UPC
CODE
DESCRIPTION
HPS30
81030
High Pressure Sodium Starter
BALLAST
design, color coded for ease of installation.
BLACK
RED
TAP
H.P.S.
STARTER
WHITE
LINE
TORK 93
ORDERING INFO
CATALOG
NO.
UPC
CODE
TRP-1**
82032
TRP-2**
82033
TRP400*
82132
TRP402*
82133
TRP800*
82135
TRP802*
82136
DESCRIPTION
Single Transformer
Relay Powerpack
Single Transformer
Relay Powerpack
Four Transformer
Relay Powerpack
Four Transformer
Relay Powerpack
Eight Transformer
Relay Powerpack
Eight Transformer
Relay Powerpack
INPUT
VOLTAGE
120VAC
277VAC
120VAC
277VAC
120VAC
277VAC
SURGE SUPPRESSOR
FOR HIGH ELECTRICAL NOISE
EASY INSTALLATION: Universal 3 wire
DIGITAL
CONTROLS
ENCLOSURE: Metal NEMA 1 Indoor
enclosure (see page 153 for enclosure
dimensions).
*Not for use with occupancy sensors.
**For replacement parts only. For newer style Transformer Relay Power Pack, see
TRP-U on page 116.
WIRING DIAGRAMS
HIGH GRADE MATERIAL: All components
are sealed with high grade die-electric
material to protect against contaminants and
other adverse environmental conditions.
WEIGHT: 7 oz.
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
COMMON
CENTER
CONTACT
LAMP
SHELL
APPLICATIONS
For high electrical noise
interference, recommended
for all digital controls.
ORDERING INFO
CATALOG
NO.
UPC
CODE
DESCRIPTION
90058-1
81024
Surge Suppressor
TORK 94
IN-WALL TIMERS
FEATURES
QUICK LOOK
SS720A SERIES
SPECIFICATIONS
24 HOUR OR 7 DAY
DIGITAL IN-WALL
TIME SWITCH
TIMING ACCURACY: Line frequency.
INPUT VOLTAGE: 125VAC, 60Hz.
WIRE SIZE: #14AWG.
OPERATING TEMPERATURE:
32°F to +104°F (0°C to +40°C).
APPLICATIONS
SS700Z
SS721Z
SS720A
701A
SSA
SSA-R24
SS
D1060
D212
A
C
Page No.
99
99
98
101
102
102
103
104
105
106
Timer Type
7 Day
Digital
7 Day
Digital
7 Day
Digital
24 Hour
Mechanical
Auto OFF
Digital
Auto OFF
Digital
Auto OFF
Electronic
Auto OFF
Electronic
Auto OFF
Mechanical
Auto OFF
Mechanical
Voltage
120/277
120/277
120
120
120/277
24
24/120/
208-240/277
120
ON
1 min.
1 min.
1 min.
30 min.
OFF
1 min.
1 min.
1 min.
30 min.
Minimum
Settings
5 min-12 hr 5 min-12 hr
10-60 min.
1 min-18 hr
10 min-8 hr 10 min-8 hr
2-12 hr
Outdoor security lighting
Interior lights for lived-in look
Fans and motors
Appliances
125/250/277 125/250/277
Various
2 min-12 hr
Various
2 min-12 hr
ORDERING INFO
Manual Override
Yes
Yes
Sunrise/Sunset
Yes
Yes
ON/OFF Set Points
10 Pair
10 Pair
Yes
Yes
SCHEDULING: 7 ON and OFF pairs of set
points for individual programs on each day of
the week. Minimum setting is 1 minute.
7 Pair
24
Flash Warning
TORK 97
Capacitor
Capacitor
Battery
Switch Type
SPST
SPST
SPST
Resistive Ratings
16A
16A
15A
SPST
NEW!
CATALOG
NO.
UPC
CODE
INPUT SUPPLY
(VAC) 60 Hz
COLOR
SS720A
14017
120
White
SS720AA
14018
120
Light Almond
RANDOM MODE: Varies ON and OFF
times to create "lived in" look when away.
Yes
Audible Warning
Power Outage Backup
FEATURES
Yes
Yes
Yes
Capacitor
Capacitor
SPST
15 & 20A 800W/1200W
Yes
DAYLIGHT SAVING: Manual button push
for one hour adjustment.
Yes
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
CONTACT RATINGS
TYPE
VOLTAGE
RATING
General Purpose
120VAC
15A
WIRING: Requires a neutral.
Resistive
120VAC
15A
CLOCK FORMAT: AM/PM.
Tungsten
120VAC
15A
Motor
120VAC
1HP
Electronic Ballast
120VAC
500VA
SPDT
SPST or SPDT
SPST
SPST
SPST or DPST
POWER OUTAGE BACKUP: Rechargeable
Ni-MI battery retains time and schedule.
1A
4A or 7.5A
15
20/10/10A
20/10/10A
WALL PLATE: Supplied with standard single
gang decorator wall plate.
TORK 98
SS700Z & SS721Z
SERIES
BACKUP WITHOUT
BATTERY, ECO FRIENDLY!
NEW!
SUNSET / SUNRISE, ASTRONOMIC
7 DAY IN-WALL TIMER
SS700Z SERIES
TIMING ACCURACY: Line frequency.
energy
RATING
INPUT VOLTAGE: 120/277VAC, 50/60Hz.
Resistive
16A
120/277VAC
16A
WIRE SIZE: #12AWG input/output - #16AWG
3-way (remote).
Ballast
10A
120/277VAC
13A
Tungsten
8A
120VAC
8A
Pilot Duty
360VA
120VAC
720VA
Motor
1⁄2HP
120VAC
1HP
CALIFORNIA Title 24
ASHRAE 90.1
Outdoor security lighting
Interior lights for lived-in look
Fans and motors
Appliances
SS721Z SERIES
VOLTAGE
TYPE
OPERATING TEMPERATURE:
32°F to +104°F (0°C to + 40°C).
responsible
APPLICATIONS
CONTACT RATINGS
SPECIFICATIONS
With wall plate
(not included)
RATING
WIRING DIAGRAMS
ORDERING INFO
CONTACT RATINGS
CATALOG
NO.
UPC
CODE
INPUT SUPPLY
(VAC) 50/60 Hz
SWITCH
TYPE
COLOR
SS700Z
14019
120/277
SPST
White
SS700ZA
14020
120/277
SPST
Light Almond
SS721Z
14027
120/277
SPST
White
SS721ZA
14028
120/277
SPST
Light Almond
FEATURES
SCHEDULING: 10 ON and OFF pairs of
set points for individual programs on each
day of the week. 11 day groups speed
programming. Minimum setting is 1 minute.
ASTRONOMIC: Sunset and sunrise times
are adjustable from 10°- 60° Northern
or Southern latitudes. Can be individually
offset +/- 1-240 minutes for earlier or later
operation.
RANDOM MODE: Varies ON and OFF
times to create lived in look when away.
DAYLIGHT SAVING: Automatic
adjustment (can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
MANUAL MODE: Does not run programs
until set to AUTO (automatic) mode.
VACATION MODE: No operation when
away.
WIRING DIAGRAM: INSTALLATION SS721Z
EASY WIRING:
SS700Z does not require a neutral, can be
used as a 3-way switch.
SS721Z Requires a neutral, can be used as
a 3-way switch.
H
COMMERCIAL GRADE SPECS: Control
lighting contactors and 277VAC loads.
Compatible with CFL lamps.
Blue
Red
Black
Load
White
CLOCK FORMAT: AM/PM.
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides 2
days of real time backup.
Black
N
N
Ground
WIRING DIAGRAM: THREE-WAY INSTALLATION SS721Z
Connect a wire inside the gang-box between Traveler A and Hot.
ORDERING INFO
Green
Black
Blue
Black
Traveler A
H
Black
Red
Traveler B
Load
White
N
N
Ground
Green
IN-WALL TIMERS
TORK 99
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 100
701A & 711A SERIES
SPECIFICATIONS
SPECIFICATIONS
24 HOUR
IN-WALL TIME SWITCH
INPUT VOLTAGE: 125VAC, 60Hz.
WIRE SIZE: #14AWG.
SSA SERIES
SPECIFICATIONS
DIGITAL AUTO OFF
IN-WALL
TIME SWITCH
TIMING ACCURACY: .002%.
INPUT VOLTAGE:
120/277 VAC, 50/60Hz.
OPERATING TEMPERATURE:
32°F to +104°F (0°C to +40°C).
APPLICATIONS
WIRE SIZE: #18AWG.
APPLICATIONS
Offices, meeting rooms, library aisles
Stock and equipment rooms
Exhaust fans – work areas, utility
rooms, bathrooms
Hot tub heaters and circulating pumps
Timed override lighting and HVAC for
after hours and for loads controlled
by electromechanical or digital time
switches.
Porch or patio
Doorway
Pool
Outdoor security lighting
ORDERING INFO
CATALOG
NO.
UPC
CODE
INPUT SUPPLY
SSA100
14010
120/277 VAC
SSA200
14011
120/277 VAC
SSA100R-24
14014
24VAC/24VDC
SSA200R-24
14015
24VAC/24VDC
LCS115M
82082
OPERATING TEMPERATURE:
0°F to +100°F (-17°C to +37°C).
TIME
SETTINGS
OUTPUT
CONTACTS
Minutes: 5, 15, 30
Hours: 1, 3, 6, 9, 12
Minutes: 10, 20, 40
Hours: 1, 11⁄2, 2, 4, 8
Minutes: 5, 15, 30
Hours: 1, 3, 6, 9, 12
Minutes: 10, 20, 40
Hours: 1, 11⁄2, 2, 4, 8
Momentary Switch
for Override (white)
SPST
SPST
SPDT
SPDT
SPST
CONTACT RATINGS
CLOCK FORMAT: AM/PM marked on
dial.
WALL PLATE: Supplied with single gang
wallplate.
INPUT SUPPLY
(VAC) 60 Hz
8-IN-1 TIMING: Choose from 8 preset ON
intervals.
COLOR
701A
10113
125
White
701AA
10118
125
Light Almond
711A
10114
125
White
MANUAL SCROLL-UP: Option allows
adjustment in 10 minute intervals.
FLASH WARNING: Optional flicker feature
turns load off for 1 second, 2 minutes before
end of timed cycle and again 1 minute before
end of timed cycle.
CONTACT RATINGS
TYPE
VOLTAGE
General Purpose
800W
800W
1200W
1⁄6HP
Pilot Duty
30V
1V min.
120VAC
30V
1V min.
240VA
1A
100µA
RATING
701A SERIES
711A SERIES
125 VAC
20A
15A
Resistive
125 VAC
20A
15A
Tungsten
125 VAC
1500W
1250W
Motor
125 VAC
1 HP
1⁄2HP
Ballast
SSA100/200
SSA100/200R-24
WIRING DIAGRAMS
SSA100/200
AUDIBLE WARNING: Optional beep will
sound every 12 seconds during the last 2
minutes of timed cycle.
BLACK
HOT
GREEN
120V GROUND
GREEN /YELLOW
277V GROUND
RED
TAMPER RESISTANT: Time ON interval
preset hidden behind wall plate.
RED
EASY SET: Dip switches provide quick set-up
of timing and options.
EASY WIRING: No neutral needed, great
for retrofit.
BACKLIT DISPLAY: Numerical read-out of
time remaining includes graphic bar showing
time remaining in 10% increments. Stands out
strongly in lighted and dark areas.
BLACK
ORANGE
BLUE
GREY
REMOTE
OVERRIDE
(+) 24VAC
or
(–)
VDC
NC
C
NO
YELLOW
YELLOW
SSA200R-24
USING TRP TRANSFORMER RELAY POWERPACK
BLACK
ORANGE
BLUE
GREY
REMOTE
OVERRIDE
NC
C
NO
YELLOW
YELLOW
LOW
VOLTAGE
20 AMP
LOAD
L
RED
WALL PLATE: Supplied with white standard
single gang decorator wall plate.
SSA-R24: Offers low voltage control with
SPDT output and includes momentary input.
NEUTRAL
LOAD
RED
WIRING: Requires a neutral.
Motor
120VAC
120VAC
277VAC
120VAC
RED
BLACK
BLUE
N
BLACK
VACATION MODE: Set timer OFF with
no change of tripper settings.
Tungsten
RED
BYPASS SWITCH: Slide switch for ON,
OFF, or TIMER (automatic) operation.
NEW!
UPC
CODE
RATING
TORK
TRP
SCHEDULING: Minimum ON setting is
30 minutes. Dial has 48 captive trippers.
CATALOG
NO.
VOLTAGE
WHITE
ORDERING INFO
FEATURES
TYPE
FEATURES
L
IN-WALL TIMERS
TORK 101
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 102
SS SERIES
SPECIFICATIONS
AUTO OFF
IN-WALL TIME SWITCH
TIMING ACCURACY:
±5% @ 60° to 80°F.
D SERIES
SPECIFICATIONS
SPECIFICATIONS
NEW!
ELECTRONIC AUTO OFF
IN-WALL TIME SWITCH
TIMING ACCURACY: Line voltage.
INPUT VOLTAGE: 120VAC, 60Hz.
INPUT VOLTAGE:
24/120/208-240/277VAC, 50/60Hz.
WIRE SIZE: #14AWG.
OPERATING TEMPERATURE:
32°F to 122°F (0°C to 50°C).
WIRE SIZE: #18AWG.
OPERATING TEMPERATURE:
0°F to +100°F (-17°C to +37°C).
APPLICATIONS
APPLICATIONS
Whole house fans
Indoor/Outdoor lighting
Bathroom fans and lights
Self storage
Bathroom fans and lights
Indoor/Outdoor lighting
Storage areas
Hospitality areas
ORDERING INFO
ORDERING INFO
FEATURES
VARIABLE TIMING: Choose from 1 minute
to 18 hours.
FLASH WARNING: “F” suffix models with
flicker feature turns load off for 1⁄2 second, 2
minutes before end of timed cycle and again 1
minute before end of timed cycle.
AUDIBLE WARNING: “B" suffix model will
buzz that every 12 seconds during the last 2
minutes of timed cycle.
TAMPER RESISITANT: Time ON interval
preset is hidden behind wall plate.
EASY SET: Small screw driver adjustment
provides quick set-up of timing.
EASY WIRING: No neutral needed, great
for retrofit.
CATALOG
NO.
INPUT SUPPLY
(VAC) 50/60Hz
WARNING BEFORE
TIME OUT
SWITCH
TYPE
SS20
14005 24/120/208-240/277
None
Single pole
SS20F
14008 24/120/208-240/277
*Flicker
Single pole
SS13F
14007 24/120/208-240/277
*Flicker
3-way
SS13B
14006 24/120/208-240/277
**Beep
3-way
*Flicker feature turns load OFF for ½ second, 2 minutes before end of timed cycle and again 1 minute
before end of timed cycle.
**Beep feature will begin a ½ second audible warning every 12 seconds during the last 2 minutes of
timed cycle.
CONTACT RATINGS
TYPE
SS13F &
SS13B
3-WAY: SS13 SERIES replaces standard
3-way switch with no re-wiring.
COLOR: White.
UPC
CODE
SS20 &
SS20F
FEATURES
VARIABLE TIMING:
Button push changes time ON setting.
D1060M: 10, 20, 30, 60 minute.
D212H: 2, 4, 8, 12 hour.
LED DISPLAY: Indicator moves to new range
as timer counts down.
TAMPER RESISTANT: Time ON interval preset.
EASY SET: No adjustments, just wire and go!
WIRING: Requires a neutral.
THREE COLORS: Ivory, Light Almond, White.
MINIMUM LOAD
CONTACT
RATINGS
VOLTS
WATTS
.25-4.0A Resistive
.25-4.0A Ballast*
.25-4.0A Tungsten
1⁄8HP @ 120VAC
1⁄3HP @ 240VAC
.50-7.25A Resistive
.50-7.25A Ballast*
.50-4.0A Tungsten
1⁄6HP @ 120VAC
1⁄2HP @ 204VAC
24
120
208
240
277
24
120
208
240
277
6
30
50
60
70
12
60
105
120
150
CATALOG
NO.
UPC
CODE
INPUT
SUPPLY
(VAC) 60Hz
TIME
SETTINGS
OUTPUT
CONTACTS
D212H
14021
120
Ivory
2, 4, 8, 12 HOURS
D212HA
14022
120
Light Almond
2, 4, 8, 12 HOURS
D212HW
14023
120
White
2, 4, 8, 12 HOURS
D1060M
14025
120
Ivory
10, 20, 30, 60 MINUTES
D1060LA
14024
120
Light Almond
10, 20, 30, 60 MINUTES
D1060MW
14025
120
White
10, 20, 30, 60 MINUTES
CONTACT RATINGS
TYPE
VOLTAGE
RATING
General Purpose
120VAC
15A
Resistive
120VAC
1000W
Tungsten
120VAC
1000W
Motor
120VAC
1⁄4HP
*Not compatible with compact fluorescent lamps (CFL) and electronic fluorescent ballasts.
IN-WALL TIMERS
TORK 103
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 104
A SERIES
SPECIFICATIONS
SPRINGWOUND AUTO OFF
IN-WALL TIME SWITCH
INPUT VOLTAGE:
125/250/277VAC, 50/60Hz.
TERMINAL SIZE: #12AWG.
C SERIES
SPECIFICATIONS
COMMERCIAL STYLE
SRINGWOUND AUTO OFF
IN-WALL TIME SWITCH
INPUT VOLTAGE:
125/250/277VAC, 50/60Hz.
TERMINAL SIZE: #12AWG.
OPERATING TEMPERATURE:
32°F to 122°F (0°C to 50°C).
OPERATING TEMPERATURE:
32°F to 122°F (0°C to 50°C).
ORDERING INFO
APPLICATIONS
Whole house fans
Indoor/Outdoor lighting
Bathroom fans and lights
Self storage
CATALOG
UPC
NO.
CODE
15 MINUTE MAX.
Wallplate not
included
A515MH
15020
A515MHW
15120
A515M
15013
A515MW
15113
A515MA
15127
HOLD
FEATURE
With Hold
APPLICATIONS
COLOR
Ivory
White
Ivory
No Hold
Wallplate
included
Ventilating fans
HVAC
Whirlpools
Self storage
Motors and pumps
White
Light Almond
30 MINUTE MAX.
A530MH
15021
A530MHW
15121
A530M
15014
A530MW
15114
CONTACT RATINGS
FEATURES
TYPE
VARIABLE TIMING: Twist knob for time
ON setting. Time ON lengths from 15 minutes
to 12 hour vary by model.
VOLTAGE
RATING
125VAC
250VAC
277VAC
125VAC
250VAC
277VAC
20A
10A
10A
20A
10A
10A
125VAC
7A
Resistive
Inductive
HOLD FEATURE: Some models have position
for constant ON.
Tungsten
EASY SET: No adjustments. Just wire and go!
EASY WIRING: No neutral required. Great
for retrofit! Use as single or in multi-gang box
with no de-rating.
125VAC
250VAC
Motor
1HP
2HP
A530MA
15022
A560MHW
15122
A560M
15015
A560MW
15115
A502HHW
15123
A502H
15016
A502HW
15116
3
9
6
0
0
12
12
3
9
6
9
A506HHW
15125
A506H
15018
9
A506HW
15118
With Hold
No Hold
Ivory
White
With Hold
No Hold
With Hold
No Hold
FEATURES
VARIABLE TIMING: Twist knob for time
ON setting. Time ON lengths from 15 minutes
to 12 hour vary by model.
Ivory
HOLD FEATURE: Some models have position
for constant ON.
White
EASY SET: No adjustments. Just wire and go!
White
EASY WIRING: No neutral required. Great
for retrofit!
Ivory
SWITCH TYPE: SPST, except C460M and
C412H – DPST
White
COLOR: Metal-brushed aluminum.
White
WALL PLATE: Includes real metal wall plate
with screw mounting, to add extra security for
commercial applications.
Ivory
TYPE
VOLTAGE
RATING
125VAC
250VAC
277VAC
125VAC
250VAC
277VAC
20A
10A
10A
20A
10A
10A
Tungsten
125VAC
7A
Motor
125VAC
250VAC
1HP
2HP
Resistive
Inductive
3
A512HH
15026
A512HHW
15126
A512H
15019
A512HW
15119
9
0
3
21
CAUTION: This timer is not to be used in precision timing applications where
inaccurate timing could have dangerous consequences (i.e. sun lamp, sauna, etc.).
6
15501
HOLD
FEATURE
No Hold
30 MINUTE MAX.
C530M
15503
No Hold
60 MINUTE MAX.
NEW!
C560M
15505
No Hold
C560MH
15506
With Hold
C460M*
15011
No Hold
2 HOUR MAX.
C502H
15507
No Hold
6 HOUR MAX.
C506H
15511
No Hold
12 HOUR MAX.
21
T OR K
1
C515M
White
With Hold
Ivory
NEW!
White
C512H
15513
No Hold
C512HH
15514
With Hold
C412H*
15010
No Hold
*DPST switch type.
1
2
CATALOG
UPC
NO.
CODE
15 MINUTE MAX.
12 HOUR MAX.
0
1
6
2
Light Almond
ORDERING INFO
CONTACT RATINGS
1
T OR K
2
White
6 HOUR MAX.
POT
2
0
12
No Hold
2 HOUR MAX.
POT
0
White
Ivory
15128
A560MH
COLOR: Ivory, Light Almond, White.
12
Ivory
60 MINUTE MAX.
SWITCH TYPE: SPST.
WALL PLATE: Fits standard or decorator
style wall plates, see below (not included).
With Hold
9
No Hold
Ivory
White
CAUTION: This timer is not to be used in precision timing applications where
inaccurate timing could have dangerous consequences (i.e. sun lamp, sauna, etc.).
All A Series timers have SPST switch type.
IN-WALL TIMERS
TORK 105
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 106
OCCUPANCY SENSORS
OSWS SERIES
SENSOR TECHNOLOGY
& PLACEMENT GUIDE
TECHNOLOGY
PIR AND ULTRASONIC
A Passive Infrared Sensor (PIR sensor), is a device that measures infrared
radiation (IR), or heat, from objects in its field of view. Because it only receives
information, it is considered passive. The IR sensor views a human body as an
IR generating object. The lens of the occupancy sensor breaks up the field of
view into IR sensitive bands. The occupancy sensor is designed to only react
when heat is sensed moving from band to band. For PIR occupancy sensors to
work object must have direct “line of sight” to the PIR sensor.
PLACEMENT GUIDELINES
PIR SENSOR, DECORATOR STYLE
IN-WALL
OCCUPANCY SENSOR
• Designed for ceiling mounting at a height of 8-10 feet (mounting
sensor at greater heights decreases the sensitivity to motion, while
lower mounting height will decrease range).
• The sensor needs a visually unobstructed view of the normally
occupied workspace and entry door(s).
• Avoid sensor placement with a direct view out a doorway. Placing the
sensor offset from the center and away from the door is
recommended.
Both technologies show higher sensitivity closer to the sensor to allow small
•
If the occupant cannot see a PIR sensor from their normal work
movements to be noticed. Sensitivity reduces further away from the sensor and
position,
the sensor will not be able to detect their presence.
may require a walking step to activate the sensor.
• File cabinets, partitions, or walls are typical types of obstructions. If
there are other obstructions between the sensor and the occupant, an
ultra-sonic or dual technology ceiling sensor is recommended.
• When the light level feature is used, mount within 15 feet of the
widows or skylight and avoid mounting the sensor close to lighting
WALL SENSOR
fixtures.
A Wall Switch Sensor provides a 180° coverage pattern, extending outward
•
Place
the sensor no closer than 5 feet to an HVAC airCEILING
duct whenAND
usingWALL OCC SENSOR SENSING PATTERNS
CEILING AND WALL OCC SENSOR SENSING PATTERNS
from the sensor. This will allow for instant turn ON when an occupant enters the
dual technology sensors.
space. Total area covered will be over 400 square feet.
• Open office designs encourage placement of the sensors to allow
overlapping coverage of small motion range and a clear view into
• Proper placement gives the sensor a clear line of sight to the entry door
each cubicle. Walking step motion may cover the entry to the space.
without viewing the hallway.
Dual technology units provide added sensitivity to small motion.
• The occupant must be able to see the sensor from their normal work position
otherwise the sensor will not be able to detect their presence.
• For offices where there are other obstructions between the sensor and the
occupant or the entry door, a ceiling sensor is required.
An Ultrasonic Sensors (US sensor) is a technology that works on a principle
similar to radar or sonar. It is an active technology that sends and receives. It
emits an inaudible high-frequency sound wave and evaluates the echo which
is received back after bouncing around in the room. This allows the sensor to
evaluate the whole room and can “look” over walls and obstructions to identify
movement.
PLACEMENT GUIDELINES
CEILING AND WALL OCC SENSOR SENSING PATTERNS
CONTACT RATINGS:
OSWS9P-120: 1000W Ballast, 800W
Incandescent, 1⁄6HP at 120VAC.
OSWS9P-277: 1800W Ballast at 277VAC.
OSWS9PD & OSWS9PDM: 1000W Ballast, 800W
Incandescent, 1⁄6HP at 120VAC, 1800W Ballast
at 277VAC.
responsible
energy
CALIFORNIA Title 24
CEILING SENSOR
A Ceiling Sensor provides a 360° coverage pattern of up to 1200
square feet when using passive infrared only. When using dual
technology the coverage pattern extends to over 2000 square feet.
Barriers within the space that block line-of-sight to sensor detection will
decrease coverage area when using passive infrared by itself, ultrasonic
dual technology will allow the sensor to get around the obstructions.
SPECIFICATIONS
ASHRAE 90.1
APPLICATIONS
ADJUSTABLE TIME DELAY:
30 seconds - 30 minutes.
Offices and hotels
Classrooms
Conference rooms
Lavatories
Hallways
OPERATING TEMPERATURE:
32° to 131°F (0° to 55°C).
MOUNTING: Box mount.
FEATURES
OSWS9P-120, OSWS9P-277 & OSWS9PD:
OPERATION: Automatic ON and automatic OFF
based on occupancy detection.
OFF DELAY: Selectable from 30 seconds to 30
minutes.
MANUAL OVERRIDE: Includes ON and OFF
switch.
EASY WIRING: No neutral required. Great for
retrofit.
OSWS9PD ALSO INCLUDES:
SENSITIVITY ADJUSTMENT: For PIR range.
DAYLIGHTING MODE: Adjustable level to
keep lights OFF even when occupancy is sensed if
adequate light exists in the room from windows or
skylights.
ORDERING INFO
CATALOG
NO.
UPC
CODE
DESCRIPTION
OUTPUT
CONTACTS
OSWS9P-120
82077
PIR in-line wall switch
120VAC
OSWS9P-277
82078
PIR in-line wall switch
277VAC
OSWS9PD
82079
120/277VAC
OSWS9PDM
82080
PIR in-line wall switch
with ambient light sensor
PIR in-line wall switch
manually activated
WIRING & COVERAGE DIAGRAMS
Wall Mounting Box
OSWS9PDM - VACANCY SENSOR:
OPERATION: Manual push button on and then
automatic OFF.
LINE
(Black)
OFF DELAY: Selectable from 30 seconds to 30
minutes.
LOAD
(Red)
SENSITIVITY ADJUSTMENT: For PIR range.
DAYLIGHTING MODE: Adjustable level to
keep lights OFF even when occupancy is sensed if
adequate light exists in the room from windows or
skylights.
MANUAL OVERRIDE: Includes ON and OFF
switch.
120/277VAC
GND
(Green)
Top and Side Coverage Pattern Diagrams
EASY WIRING: No neutral required.
35'
16'
180° Coverage
15°
4.0'
15°
35'
TORK 109
TORK 110
OSC15PLS
SPECIFICATIONS
PIR SENSOR, WITH AMBIENT LIGHT
OVERRIDE, MULTI-VOLTAGE
INTEGRAL POWERPACK,
CELING MOUNTED
OCCUPANCY SENSOR
VOLTAGE: 120 - 347VAC.
ADJUSTABLE LIGHT LEVEL: 5FC - 200FC.
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
ADJUSTABLE TIME DELAY: 30 seconds 30 minutes (DIP switch).
TEST MODE: 5 seconds, upon initial power-up
or DIP switch reset.
APPLICATIONS
PIR COVERAGE: 1200 sq. ft.
Offices and hotels
Classrooms
Conference rooms
Lavatories
Hallways
sensitivity adjustment:
Full or 50% low (DIP switch).
operating temperature:
32° to 131°F (0° to 55°C).
mounting: Ceiling or box mount.
contacts: SPST dry contacts.
FEATURES
contact ratings: 800W Incandescent,
1000W ballast at 120VAC. 1800W Ballast at
277VAC. 2200W Ballast at 347VAC.
OPERATION: Automatic ON and automatic
OFF based on occupancy detection.
OSC12PL
& OSC5PL
SPECIFICATIONS
VOLTAGE: 24VDC.
PIR SENSOR
CELING MOUNTING
OCCUPANCY SENSORS
UPC
CODE
INPUT
SUPPLY
COVERAGE
(FEET)
DESCRIPTION
OSC15PLS
82076
120-347VAC
1200
WHITE
WIRING & COVERAGE DIAGRAMS
OSC15PLS
SENSOR
N
LOAD
WHITE (NEUTRAL)
BLACK (LINE)
RED
RED
ADJUSTABLE LIGHT LEVEL:
10FC - 150FC.
Offices
Classrooms
Conference rooms
Lavatories
Hallways
ADJUSTABLE TIME DELAY:
5 seconds - 30 minutes (DIP switch).
TEST MODE: 5 seconds, upon initial
power-up or DIP switch reset.
PIR COVERAGE: 1200 sq. ft.
OSC5PL / OCCUPANCY SENSOR
ASSORTED
SENSING
PATTERNS
OSC5PL
/ OCCUPANCY
SENSOR
ASSORTED SENSING PATTERNS
FEATURES
18ft
SENSITIVITY ADJUSTMENT:
Full or 50% low (DIP switch).
18ft
MOUNTING: Ceiling or box mount.
OPERATION: Automatic ON and automatic OFF
based on occupancy detection.
DAYLIGHTING MODE: Selectable to
keeps lights off when occupancy is sensed
if adequate light exists in the room from
windows or skylights.
CATALOG
NO.
POWER SUPPLY: TRP-U Power Pack
(up to 6 units).
CALIFORNIA Title 24
APPLICATIONS
OFF DELAY: Selectable from 30 seconds to 30
minutes.
POWER SWITCHING: Built-in power pack
for direct line voltage control.
energy
ASHRAE 90.1
OFF DELAY: Selectable from 30 seconds to
30 minutes.
ORDERING INFO
CURRENT CONSUMPTION: 9mA.
responsible
OPERATING TEMPERATURE:
32° to 131°F (0° to 55°C).
ORDERING INFO
12ft
COVERAGE
(FEET)
12ft
ECOSETTING: Learns typical use patterns and
adjusts the OFF delay for the most efficient time.
CATALOG
NO.
UPC
CODE
INPUT
SUPPLY
WALK-THROUGH MODE: Selectable to turn
lights OFF after only 3 minutes. If no activity is
detected after 30 seconds of occupancy detection,
lights turn OFF.
OSC5PL
82083
24VDC
500
White
OSC12PL
82081
24VDC
1200
White
TRP-U
82030
120/277VAC
DAYLIGHTING MODE: Selectable to keep lights
OFF when occupancy is sensed if adequate light
exists in the room from windows or skylights.
LCS115M
82082
DESCRIPTION
Power Pack
Momentary Switch
COVERAGE DIAGRAMS
PRESENTATION MODE: Optional MANUAL OFF
by an accessory wall switch (LCS115M). Sensor
will keep lights OFF while movement in room is
detected, then return to automatic ON after 5
minutes.
DIP SWITCH
Sensitivity
Time Delay
1
50%
VACANCY MODE: Optional MANUAL ON by
an accessory wall switch (LCS115M) and then
automatic OFF.
100%
Walk Through
3
Audible Alert
4
Enabled
Visible Alert
Vacancy
6
Disabled
Enabled
WARNING BEFORE OFF: Optional visual flash
warning and/or audible beep warning one minute
before turn OFF.
Enabled
20 Minutes
25 Minutes
Hold ON
30 Minutes
Disabled
OFF
ON
8
Disabled
15 Minutes
Enabled
7
Disabled
30 Seconds
5 Minutes
10 Minutes
5
Disabled
MANUAL OVERRIDE: Optional manual control
by an accessory wall switch (LCS115M) for ON and
OFF.
2
5 Sec/EcoSet
Factory Setting
9
Enabled
OSC5PL
OSC12PL
PLUG TERMINAL: Quick disconnect for sensor.
POWER SWITCHING: Transformer relay power
pack (TRP-U) required to power sensor and provides
line voltage switching. (see page 116 for product
information).
OCCUPANCY
SENSORS
TORK 111
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
22
6.7
11
7
3
3
7
11
TORK 112
OSC2OUP
DUAL TECHNOLOGY
CELING MOUNTED
PIR/ULTRASONIC
OCCUPANCY SENSOR
SPECIFICATIONS
VOLTAGE: 24VDC.
energy
CALIFORNIA Title 24
ASHRAE 90.1
APPLICATIONS
PIR COVERAGE: 1500 sq. ft. (adjustable).
SENSITIVITY ADJUSTMENT: Individual setting
range for ultrasonic of 50% and PIR of 75%.
ULTRASONIC OUTPUT: 32Hz
MOUNTING: Ceiling or box mount.
OPERATION: Automatic ON and automatic
OFF based on occupancy detection.
OFF DELAY: Selectable from 8 to 40
minutes.
ECOSETTING: Learns typical use patterns
and adjusts the OFF delay for the most
efficient time.
POWER SWITCHING: Transformer relay
power pack (TRP-U) is required to power
sensor and provide line voltage switching
(see page 116 for product information).
ADJUSTABLE TIME DELAY:
8 - 40 minutes.
US COVERAGE: 2000 sq. ft. (adjustable).
FEATURES
TORK 113
VOLTAGE: 24VDC.
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
APPLICATIONS
HUMIDITY: 0 to 95% R.H. non-condensing for
indoor use only.
OFF DELAY: Selectable from 8 to 40
minutes.
ORDERING INFO
CATALOG
NO.
UPC
CODE
INPUT
SUPPLY
COVERAGE
(FEET)
DESCRIPTION
OSCS20UP
82075
24VDC
2000 ft US
1500 ft PIR
White
TRP-U
82030
120/277VAC
Power Pack
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
POWER SWITCHING: Transformer relay
power pack (TRP-U) is required to power
sensor and provide line voltage switching
(see page 116 for product information).
ADJUSTABLE TIME DELAY:
8 - 40 minutes.
SENSITIVITY ADJUSTMENT: Manual
setting range of 50%.
ULTRASONIC OUTPUT:
OSC5U: 40kHz
OSC10U/OSC20U: 32kHz
MOUNTING: Ceiling or box mount.
OPERATING TEMPERATURE:
32° to 104°F (0° to 40°C).
HUMIDITY: 0 to 95% R.H. non-condensing
for indoor use only.
ECOSETTING: Learns typical use patterns
and adjusts the OFF delay for the most
efficient time.
MOTION INDICATION: Green for
ultrasonic motion. Indicator may be disabled.
POWER SUPPLY: TRP-U Power Pack
(up to 4 units).
US COVERAGE: 2000 sq. ft. (adjustable).
FEATURES
OPERATION: Automatic ON and automatic
OFF based on occupancy detection.
CURRENT CONSUMPTION: 33mA.
TEST MODE: 8 seconds, upon initial
power-up for 1 hour.
Offices and hotels
Classrooms
Conference rooms
Lavatories
Hallways
OPERATING TEMPERATURE:
32° to 131°F (0° to 55°C).
COVERAGE DIAGRAMS
OCCUPANCY
SENSORS
SPECIFICATIONS
ULTRASONIC, CEILING MOUNTING
OCCUPANCY SENSORS
POWER SUPPLY: TRP-U Power Pack
(up to 3 units).
TEST MODE: 8 seconds, upon initial
power-up for 1 hour.
Offices and hotels
Classrooms
Conference rooms
Lavatories
Hallways
MOTION INDICATION: Red for infrared
motion, Green for ultrasonic motion.
Indicators may be disabled.
CURRENT CONSUMPTION: 33mA.
responsible
OSC SERIES
ORDERING INFO
CATALOG
NO.
UPC
CODE
INPUT
SUPPLY
COVERAGE
(FEET)
DESCRIPTION
OSC5U
82072
24VDC
500 SQ FT
White
OSC10U
82073
24VDC
1000 SQ FT
White
OSC20U
82074
24VDC
2000 SQ FT
White
TRP-U
82030
120/277VAC
Power Pack
COVERAGE DIAGRAMS
TORK 114
ELS
TRP-U
SPECIFICATIONS
INDOOR LIGHT LEVEL
ELECTRONIC
CCUPANCY
SENSOR
responsible
energy
VOLTAGE: 24VDC.
ASHRAE 90.1
LOAD REQUIREMENTS:
Ballast 20amp @120/277VAC.
Incandescent 20amp@120VAC.
Motor 1HP @120/240VAC.
Output 150mA @24VDC (with relay connected).
POWER SUPPLY: TRP-U Power Pack (up
to 4 units).
operating temperature:
50° to 104°F (10° to 40°C).
APPLICATIONS
mounting: Ceiling or box mount.
Offices
Classrooms
Conference rooms
Hallways
LOW VOLTAGE INPUT:
Control ON: 12 - 24VDC
Hold ON: 12 - 24VDC
Hold OFF: 12 - 24VDC
Power and switching
for occupancy sensors
Power and switching
for SSA R-24 series
BAS input compatible
Demand shedding applications
Device override to hold on
Momentary switched override
Low voltage 3-way wiring
FEATURES
DAYLIGHTING CONTROL: Turns OFF
when sufficient daylight present.
ADJUSTABLE LIGHT LEVEL:
10FC - 250FC (DIP switch).
FEATURES
EASY MOUNTING: Low voltage Class 2
wiring allows recommended mounting about
3 feet from daylight sources.
OPERATION: Switches line voltage loads ON/OFF
based on a contact closure from an occupancy sensor,
AUTO OFF switch, or relay.
PRESET ON DELAY: 30 seconds prevents
false triggering.
VOLTAGE: 120/230/277VAC, 50/60Hz.
CURRENT CONSUMPTION: 9mA.
CALIFORNIA Title 24
APPLICATIONS
ADJUSTABLE OFF DELAY:
Set from 3 to 15 minutes.
SPECIFICATIONS
INTELLEGENT
POWER PACK
ORDERING INFO
CATALOG
NO.
UPC
CODE
INPUT
SUPPLY
DESCRIPTION
ELS-1
82049
24VDC
Indoor Daylight Sensor
TRP-U
82030
120/277VAC
Power Pack
operating temperature:
32° to 131°F (0° to 55°C).
ORDERING INFO
INTELLEGENT INPUT: Three additional input wires:
1. Hold OFF for demand shed control.
2. Hold ON override of local devices such as sensors.
3. Momentary switch input for remote override.
CATALOG
NO.
UPC
CODE
INPUT
SUPPLY
DESCRIPTION
TRP-U
82030
120/277VAC
Power Pack
MULTI-VOLTAGE: Tri-voltage input for flexibility.
LCS115M
82082
QUICK MOUNTING: Snaps into 1⁄2" box KO.
WIRING DIAGRAMS
MOUNTING: Box mount to 1⁄2" KO.
Momentary Switch
WIRING DIAGRAMS
ON
1 2 3 4 5 6 7
Power Pack 277V
Model TRP2
or Power Pack 120V
Model TRP1
New
Extension
Box
Existing
Junction
Box
TRP-U
LOW VOLTAGE WIRING
New Cover With
1/2 K.O. Provision
PHOTO SENSOR
ORIENTATION ARROW
UNDER IVORY COVER
PROGRAMMABLE 7-SECTION SLIDE SWITCH FOOT CANDLE SELECTION*
+
1 2 3 4 56
FOR7
SLIDE
FOOT CANDLE
#1
10FC
Warehouse
#2
25FC
#3
50FC
#4
75FC
Corridors
Machine equipment display showroom (such as
automobile and farm equipment) LOBBY (such as
airport waiting area).
Classrooms, common office areas
#5
100FC
Drafting rooms
#6
150FC
Retail display areas
250FC
High critical areas, product sorting and grading,
paint quality control.
#7
Bend Tabs After
Inserting in K.O.
Hole
New Extension Box
Only Used When
Low Voltage Wiring
Has to be Enclosed
*Slide only one switch to ON for selection, all other switches remain OFF.
OCCUPANCY
SENSORS
TORK 115
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 116
PLUG-IN TIMERS
400A SERIES
400D SERIES
INDOOR GENERAL PURPOSE 1875W
MECHANICAL MULTIPLE
ON/OFF TIMERS
INDOOR GENERAL
PURPOSE 1800W
DIGITAL PROGRAMMABLE
ON/OFF TIMERS
NEW!
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
401A
APPLICATIONS
460D
APPLICATIONS
405A
Lamps, radios, televisions
Appliances
Automatically turn ON/OFF items
in the home, gives the home a
"lived in" look while away.
Lamps, radios, televisions
Appliances
NEW!
455D
Automatically turn ON/OFF items in
the home, gives the home a "lived
in" look while away.
402A
FEATURES
454D
NEW!
422A
FEATURES
457Z
REPEAT SCHEDULE: Daily.
REPEAT SCHEDULE: 7 day programming.
VARIABLE TIMING: Multiple ON/OFF times.
VARIABLE TIMING:
460D, 454D, 455D: Manual Daylight Savings
adjustment. Random mode for lived-in look. Manual
Override ON/OFF.
ON/OFF: Manual ON/TIMER switch.
ENERGY SAVINGS: Works with CFLs and LED lamps.
403A
457Z: Turns ON at Sunset; turns OFF at Sunrise or
other times; automatic DST adjustment; Random Mode
for lived-in look; Manual Override ON/OFF.
BACKUP: Battery back-up.
ENERGY SAVINGS: Works with CFLs and LED lamps.
ACCURACY: Digital accuracy to 1 minute.
ORDERING INFO
CATALOG
NO.
UPC
CODE
401A
16001
402A
16002
403A
16013
405A
16014
422A
16019
ORDERING INFO
RATINGS
125 VAC, 15A, 1875W Resistive
125VAC, 10A, 1250W Tungsten
125VAC, 1⁄3HP
125VAC 15A, 1875W Resistive
125VAC 500W Tungsten
125VAC TV-4
NO. OF
OUTLETS
( )
TYPE OF
PLUG
DESCRIPTION
VARIABLE TIMING
SEGMENTS
CATALOG
NO.
UPC
CODE
1
Polarized
Multiple ON/OFF Lighting Timer
15 minute
460D
16017
1
Grounded
Heavy Duty 24 hour Timer
15 minute
454D
16009
1
Polarized
Powerful & Compact Automatic Timer
30 minute
455D
16015
2
Grounded
Heavy Duty 15 AMP Automatic Timer
15 minute
1
Grounded
Heavy Duty 24 hour 15AMP Timer
30 minute
NOTE: " " = Indicates outlet location.
457Z
16016
RATINGS
120VAC, 15A, 1800W General Purpose
120VAC, 15A, 1800W Resistive
120VAC, 1000W Tungsten
120VAC, 1⁄3HP, TV-5
120VAC, 15A, 1800W General Purpose
120VAC, 15A, 1800W Resistive
120VAC, 960W Tungsten
120VAC, 1⁄3HP TV-5
NO. OF
OUTLETS
( )
TYPE OF
PLUG
DESCRIPTION
1
Polarized
Daily Programmable Digital Timer
24 ON/OFFs
VARIABLE TIMING
SEGMENTS
1
Grounded
Daily Programmable Digital Timer
Different schedule for
each day of the week.
2
Grounded
Daily Programmable Digital Timer
Multiple ON/OFFs
20 ON/OFFs
2
Grounded
Ultimate Plug-In 2-Outlet Timer
Different schedule for
each day of the week.
ON at Sunset
OFF at Sunrise
NOTE: " " = Indicates outlet location.
PLUG-IN TIMERS
TORK 119
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 120
600D SERIES
600A SERIES
OUTDOOR
NEW!
GENERAL PURPOSE 1875W
7 DAY DIGITIAL WITH
PHOTOCELL, 7 DAY DIGITAL
OUTDOOR TIMERS
OUTDOOR GENERAL PURPOSE 1875W
MECHANICAL PLUG-IN
PHOTOCELL COUNTDOWN
TIMERS
APPLICATIONS
responsible
energy
CALIFORNIA Title 24
ASHRAE 90.1
Photocell
APPLICATIONS
Landscape or Christmas lighting
Controls small pumps, fountains, motors
Landscape and Christmas lighting
Control small pumps, fountains,
motors, etc.
Energy saving
601A
602A
621D & 631D
(621D without photocell)
611A
611D
FEATURES
FEATURES
REPEAT SCHEDULE: Daily.
REPEAT SCHEDULE: 7 day programming.
VARIABLE TIMING: Multiple ON/OFFs, Manual ON/
TIMER switch.
VARIABLE TIMING: Manual Daylight Savings
adjustment. Random mode for lived-in look.
Manual ON/TIMER switch. Multiple ON/OFF for
each day of the week.
PHOTO TIMER: Two styles
652A - Dial setting. ON at dusk and OFF 2, 4, 6, or 8 hours
later. 654A - Digital setting. ON dusk and OFF 1 to 9 hours
later or at random times.
652A
BACKUP: Battery back-up.
ACCURACY: Digital accuracy to 1 minute.
ENERGY SAVINGS: Works with CFLs and LED lamps.
654A
ORDERING INFO
CATALOG
NO.
UPC
CODE
601A
16020
602A
16021
611A*
16022
652A
16026
654A
16025
RATINGS
125 VAC, 15A, 1875W General Purpose
125VAC, 15A, 1875W Resistive
125VAC, 10A, 1250W Tungsten
125VAC, 1⁄2HP
125VAC, 15A, 1875W General Purpose
125VAC, 15A, 1875W Resistive
125VAc, 650W Tungsten
125VAC, 1⁄3HP, TV-5
NO. OF
OUTLETS
( )
TYPE OF
PLUG
DESCRIPTION
1
Grounded Mechanical Outdoor Timer, with18" cord
2
Grounded Mechanical Outdoor Timer, with18" cord
1
Wall Mountable
Grounded Mechanical Outdoor
Timer, with 24" cord
2
Grounded
Photocell Outdoor Timer with 6.5" cord
2
Grounded
Photocell Outdoor Timer with 6.5" cord
VARIABLE TIMING
SEGMENTS
15 minutes
Multiple ON/OFFs
15 minutes
Multiple ON/OFFs
15 minutes
Multiple ON/OFFs
Photo ON
Dawn or timed OFF
Photo ON
Dawn or timed OFF
*611A: 1⁄3HP
PHOTOCELL: 611D and 631D have built-in
photocell to always turn ON at dusk and OFF at
dawn. Add a time OFF schedule
655D
655D
Remote
WIRELESS REMOTE: 655D receives ON/OFF
signal up to 80 feet away.
ORDERING INFO
CATALOG
NO.
UPC
CODE
611D
16018
621D
16056
631D
655D*
RATINGS
NO. OF
OUTLETS
( )
TYPE OF
PLUG
1
Grounded
2
Grounded
16027
125 VAC, 15A, 1875W General Purpose
125VAC, 15A, 1875W Resistive
125VAC, 1000W Tungsten
125VAC, 8A Ballast
125VAC, 1⁄2HP
2
Grounded
16042
125VAC, 5A, 625W Resistive
125VAC, 600W Tungsten
2
Grounded
DESCRIPTION
Wall Mountable Photocell & 7 Day
Digital 2-in-1 Timer, with 24" cord
Wall Mountable, 7 Day
Digital Timer, with 18" cord
Wall Mountable Photocell & 7 Day
Digital 2-in-1 Timer, with 18" cord
Remote control
indoor/outdoor receiver
VARIABLE TIMING
SEGMENTS
Photo ON
Dawn or timed OFF
Multiple ON/OFFs for
each day of the week
Photo ON
Dawn or timed OFF
Handheld remote ON/OFF
* ETL listed for U.S. and Canada.
NOTE: " " = Indicates outlet location.
NOTE: " " = Indicates outlet location.
PLUG-IN TIMERS
TORK 121
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 122
800 SERIES
NEW!
OUTDOOR GENERAL
PURPOSE 1875W
MECHANICAL & DIGITAL
STAKE TIMERS
APPLICATIONS
Landscape and Christmas lighting
Other outdoor lighting
Energy saving
803B
806B
FEATURES
REPEAT SCHEDULE: Mechanical timer 24 hours. Digital
timer 7 day programming.
806D
MECHANICAL TIMING: Multiple ON/OFFs, Manual ON/
TIMER switch.
DIGITAL TIMING: Manual ON/TIMER switch. Multiple
ON/OFF for each day of the week.
PHOTOCELL: 806D has optional built-in photocell to
always turn ON at dusk and OFF at dawn or 1 to 12 hours
later.
ENERGY SAVINGS: Works with CFLs and LED lamps.
ORDERING INFO
CATALOG
NO.
UPC
CODE
803B
16057
806B
16037
806D
16038
RATINGS
125VAC, 15A, 1875W Resistive
125VAC, 10A, 1250W Tungsten
125VAC, 15A, 1875W Resistive
NO. OF
OUTLETS
( )
TYPE OF
PLUG
3
Grounded
6
Grounded
6
Grounded
DESCRIPTION
VARIABLE TIMING
SEGMENTS
Mechanical Outdoor Stake Timer,
with 2' cord
Mechanical Outdoor Stake Timer,
with 2' cord. 3 timed outlets and 3 untimed.
15 minutes
Multiple ON/OFFs
15 minutes
Multiple ON/OFFs
Multiple ON/OFFs for each
Digital Outdoor Stake Timer, with 6' cord. 3 day of the week or Photo
timed outlets and 3 untimed.
ON and Dawn or 1-12
hours OFF.
NOTE: " " = Indicates outlet location.
PLUG-IN TIMERS
TORK 123
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 124
TORKALERT
™
MECHANICAL
STROBE HORNS
ALARM SOUNDS
MULTI-TONE
ELECTRONIC
HORNS
ALARM
TONE
BELL
HI-LO
CHIME
SINGLE STROKE BELL
HORN
3 BEEPS, PAUSE
SIREN
SLOW WHOOP
24VDC &115VAC
APPLICATIONS
APPLICATIONS
TA880-N5
High performance for industrial
signaling applications. Offers high
sound output, low current draw and
dependable operation. Strobes use
xenon flashtube, ideal for maximum
efficiency and reliability.
TA5508H-G1
ORDERING INFO
CATALOG
NO.
UPC
CODE
INPUT
VOLTAGE
INPUT
CURRENT
(AMPS)
dB
@10 FEET
CANDELA
TA880-N5
96015
120VAC
0.115
96
15
ALARM: Penetrating mechanical sound.
TA5508H-G1
96071
24VDC
.059
strobe only
15/75
WIRING: Low current draw.
NOTE: TA880-N5 For outdoor use, unit must be mounted in a TA-WBBF outdoor backbox. See page 138
for ordering. TA5508H-G1 for indoor mounting only.
FEATURES
MOUNTING: 4" square surface mounting.
TA875-1G1
For indoor and outdoor use.
Superior sound penetration for
various room conditions. Screw
terminals accept #12AWG.
MECHANICAL
HORNS
FEATURES
OPERATING TEMPERATURE:
TA-MTS: -31˚F to +150˚F (-35˚C to +66˚C).
DIMENSIONS AND MOUNTING:
TA-MTS: 41⁄18”H x 41⁄8”W x 317⁄32”D
Can be mounted on celing or wall.
TA875-1G1: 43⁄4”H x 43⁄4”W x 13⁄8”D
1 gang, 2 gang or 4" square backbox.
TA875-1G1 24VDC HORN
CURRENT
(AMPS)
TA-MTS
ALARM
TONE
HORN
BELL
HORN 2
CODE 3 HORN
CODE 3 TONE
SLOW WHOOP
SIREN
HI-LO
TYPICAL dB
@10 FEET
0.020
0.025
0.028
0.026
0.023
0.023
0.040
0.040
91
96
93
93
97
97
95
96
TA-MTS 115VAC HORN
AMPS @ 120VAC
TYPICAL dB @10 FEET
HIGH
STANDARD
HIGH
STANDARD
OUTPUT
OUTPUT
0.050
0.041
0.050
0.050
0.042
0.050
0.045
0.042
0.042
0.039
0.040
0.042
0.040
0.042
0.041
0.039
85
82
85
82
79
85
85
82
82
75
79
75
75
82
82
79
ORDERING INFO
CATALOG
NO.
UPC
CODE
INPUT
VOLTAGE
DESCRIPTION
TA875-1G1
97641
20-31VDC,
24VDC
Multi-tone Electric Horn
TA-MTS
97674
115 VAC
Multi-tone Electric Horn
HEAVY DUTY
BELLS
4", 6", 10" DIAMETERS
AC VIBRATING BELLS
ORDERING INFO
APPLICATIONS
CATALOG
NO.
Loud tone with typical decibel
output of 103 dB. Low frequency
resonation for strong penetration
of noisy areas like boiler rooms,
water pumping stations, elevators
and air compressor rooms.
UPC
CODE
INPUT
VOLTAGE
INPUT CURRENT
(AMPS)
APPLICATIONS
SURFACE TYPE
TA874-N5
96023
120VAC, 60Hz
0.070
TA874-N5R
(Red)
97613
120VAC, 60Hz
0.070
TA875-G1
97687
24VDC
0.035
For indoor or outdoor applications.
High sound output, durable and
dependable performance. Ideal for
schools and hopsitals.
ORDERING INFO
INPUT
VOLTAGE CURRENT
(AMPS)
dB
@ 10
FEET
CATALOG
NO.
UPC
CODE
SHELL
SIZE
TA340-4G5
96001
4”
24VAC
0.320
81-90 Dawn Mist
TA340-4N5
96002
4”
120VAC
0.065
81-90 Dawn Mist
TA340-6G5
96003
6”
24VAC
0.320
81-95 Dawn Mist
TA340-6N5
96004
6”
120VAC
0.065
81-95 Dawn Mist
COLOR
WITH WEATHERPROOF BACKBOX TA-WBBF UL LISTED FOR OUTDOOR USE
FEATURES
TA876-N5
INPUT VOLTAGE: Wide input voltage
ratings for compatibility with unregulated
power supplies.
HOUSING: Steel, painted Dawn Mist.
Resonant grill design for high sound
output.
WIRING: Screw terminals for convenient
IN/OUT wiring. Low current draw for
minimizing power supply and wiring cost.
MOUNTING: To indoor box TA-BBSF
or outdoor box TA-WBBF, see accessories
page 13*.
NOTE: Use TORK signal timers for 24 hour or 7 day scheduling, see page 85.
96026
120VAC, 60Hz
0.070
FEATURES
TERMINAL SIZE: #12 - 22 AWG.
TA340-10G5
96005
10”
24VAC
0.320
84-98 Dawn Mist
WIRING: Screw terminals permit fast IN/OUT
field wiring.
TA434-4N5
98005
4"
120VAC
0.065
81-95
Red
HOUSING: Steel gong and cast aluminum. See
page 138 for dimensional drawings.
TA434-6N5
97521
6”
120VAC
0.065
81-95
Red
TA434-10N5
96522
10”
120VAC
0.065
84-98
Red
NOTE: Use TORK signal timers for 24 hour or 7 day scheduling, see page 85.
TORK ALERT ™
TORK 127
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 128
LIGHT DUTY AND
GENERAL PURPOSE
BELLS & BUZZER
WEATHERPROOF
MOTOR DRIVEN
SIREN
DIMENSIONS
FRONT VIEW
8-1/4"
Power
wires
2 feet
long
APPLICATIONS
APPLICATIONS
Designed to operate on either bell
ringing transformers or batteries.
Non-adjustable sound.
TA725
(2) 9/32"
mounting
holes
Mount siren (hardware not included)
15-3/8"
FRONT VIEW
For industrial and outdoor
use. Ideal for evacuation and
warning systems.
TA740
6-7/8"
7-1/2" dia.
(2) nuts,
loosen to
adjust siren
direction.
8-1/4"
FEATURES
ALARM: Bell ringing, non-adjustable sound.
DIMENSIONS FOR TA725:
3" H x 21⁄2" W x 1" D.
MOUNTING: Fully enclosed sturdy steel bases
and covers. Base and cover snap together, no
screws required.
ORDERING INFO
FEATURES
CATALOG
NO.
UPC
CODE
SWITCH
VAC
VDC
AMPS
dB
TA740
96228
21⁄2” Gong
8-16
3-6
1
76 @ 10'
TA744
96230
4" Gong
8-16
3-6
1
78 @ 10'
TA725
96226
Buzzer
8-16
3-6
1
88 @ 3'
ORDERING INFO
MOUNTING: Fully enclosed sturdy steel bases.
Junction box &
(2) wire nuts (not furnished)
ORDERING INFO
CATALOG
NO.
UPC
CODE
INPUT
VOLTAGE
dB
@10 FEET
AMPS
VA
TA315-1N5
96599
120VAC/DC
117
2.5
300
APPLICATIONS
Powerful and loud, pleasant sounding
push-button chimes. Ideal for homes,
apartments and offices.
ALARM: Chime.
HOUSING: Red enamel paint over heavy
gauge aluminum housing. Fully enclosed
motor. 180° swivel and adjustable
direction.
Siren power wires
(2) 9/32"
mounting
holes
PULL-DOWN STATION
APPLICATIONS
INPUT: 16V, 10VA, 120VAC.
1/2" conduit (not furnished)
6-7/8"
MANUAL FIRE
ALARM
CHIMES &
CHIME KITS
FEATURES
Power
wires
2 feet
long
INPUT VOLTAGE: 120AC & DC, 60Hz.
ALARM: Loud, distinctive tone. Designed
to be effective over standard horns or bells.
8-1/2" dia.
1/2" conduit
connector
CATALOG
NO.
UPC
CODE
TAC212WS
96064
TAC212WL
96054
TAC210W
96052
DESCRIPTION
16VAC Chime + Push Button
clip for Stucco + 10VA
Transformer
16VAC Chime +
2 Push-buttons +
10VA Transformer
16VAC Chime
DIMENSIONS
73⁄16”L x 4”W x 2”D
71⁄4”L x 43⁄4”W x 21⁄2”D
71⁄4”L x 43⁄4”W x 21⁄2”D
Designed for indoor use.
Ideal for schools, hospitals,
industrial plants, warehouses
and retail stores. Key
required to close and reset
device. Meets requirements,
BSA, MEA, CA and UL.
FEATURES
ALARM: Loud, distinctive tone. Designed to be
compatible with any control panel to initiate local
alarm signals, trip municipal fire alarm box and start
fire pumps.
ORDERING INFO
CATALOG
NO.
UPC
CODE
SWITCH
VOLTS
AMPS
TA270A
96521
SPST, NO
30V AC/DC
1
MOUNTING: Sturdy metal construction, mounts to
a standard single gang electrical box.
TORK ALERT ™
TORK 129
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 130
TELEPHONE
RELAY
TELEPHONE
STROBE
APPLICATIONS
APPLICATIONS
For single-line analog phone
lines. Emits a high intesity
flashing light when the telephone
rings. Ideal for alerting the
hearing impaired, high ambient
noise environments and quiet
zones. ADA compliant.
This device activates appliances
when a telephone ring voltage is
detected. For indoor and outdoor
use with horns, bells or strobes.
Recommended use where
ambient noise levels are high.
FCC approved.
ORDERING INFO
FEATURES
PLUG:
RJ-11C connection.
TA-B-KHD-120VAC, includes 120VAC
power cord.
RINGER
PEAK
EQUIVALENCE CANDLEPOWER
CATALOG
NO.
UPC
CODE
INPUT TELEPHONE
RING VOLTAGE
POWER
TA-B-KHD-120VAC
97101
45-130V, 20-30Hz
120VAC
0.4
50-130V, 20-30Hz
Analog line
ring voltage
1.5
TA-B-KHD-1000-PP
97102
ORDERING INFO
FEATURES
CATALOG
NO.
UPC
CODE
INPUT TELEPHONE
RING VOLTAGE
AC INPUT
VOLTAGE
RINGER
EQUIVALENCE
PEAK
CANDLEPOWER
70,000
INPUT: Accepts RJ-11C phone plug.
TA-B-8332
97100
39-150V/20-30Hz
WIRING: Hard wire connections,
for analog phone lines.
Up to
115VDC-500MA
0.6
8,000
115VAC-5A,
230VAC-2A
MOUNTING: Easily mounts to interior
surfaces, for indoor use.
MOUNTING: Weatherproof, indoor and
outdoor, includes mounting bracket.
TELEPHONE
HORN
WALL CLOCKS
QUARTZ & ELECTRIC
ORDERING INFO
QUARTZ CLOCK
APPLICATIONS
APPLICATIONS
High quality compact signaling
device. For indoor use. Easily
connects to phone systems and
enables locations with moderate
to high ambient noise to have
a loud telephone alert. FCC
approved.
Each model meets United States
Government Specifications. All
Clocks provide second hand for
accurate timing.
ORDERING INFO
FEATURES
ALARM: Adjustable tone and volume.
FEATURES
CATALOG
NO.
UPC
CODE
INPUT TELEPHONE
RING VOLTAGE
dB
@3 FEET
RINGER
EQUIVALENCE
TA-B-KHS-1000-PP
97103
50-130V, 20-30Hz
90
0.8
PLUG: RJ-11C modular connection.
MOUNTING: Grey enclosure. For indoor use, surface
mountable.
QUARTZ
Accurate to one minute per year. Low power
consumption for long battery life.
Uses AA battery (not supplied).
ELECTRIC
110VAC, 60 Hz synchronous motor. 66 inch line
cord and plug. Does not require grounding.
MOUNTING: Concealed mounting brackets allow
for simple, neat placement on walls.
CATALOG
NO.
UPC
CODE
TYPE
SIZE
FRAME
COLOR
TA1886 G
96156
QUARTZ
8”
Grey
TA1886 B
96155
QUARTZ
8”
Brown
TA1887 G
96159
QUARTZ
12”
Grey
TA1887 B
96157
QUARTZ
12”
Brown
TA1887 BK
96158
QUARTZ
12”
Black
ELECTRIC CLOCK
CATALOG
NO.
UPC
CODE
TYPE
SIZE
FRAME
COLOR
TA1880 G
96152
ELECTRIC
8”
Grey
TA1880 B
96151
ELECTRIC
8”
Brown
TA1882 G
96154
ELECTRIC
12”
Grey
TA1882 B
96153
ELECTRIC
12”
Brown
TORK ALERT ™
TORK 131
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 132
PUSH-BUTTONS
ILLUMINATED,
NON-ILLUMINATED &
WEATHERPROOF
ELECTRIC DOOR
OPENERS
REMOTE CONTROL
& CONTACT DEVICES
DIMENSIONS
TA1786B Only
1 3/8"
(34mm)
2-3/8" DIA.
1-13/16"
BETWEEN
CL
2 13/32"
(61mm)
MOUNTING HOLES
ON MODEL TA1786B and TA1786CB
MODEL TA1786CB
For unlocking or locking metal or
wooden doors using low voltage
wiring. For AC, use TA591 or
TA592 transformer.
MORTISE TYPE REMOTE OPENER
Reversible for right or left hand door. Use with mortise entrance locks having a latch
bolt with up to 1⁄2" width and throw. Dimensional drawings available on page 138.
DEVICE
CATALOG
NO.
UPC
CODE
VOLTS
AMPS
For outdoor use to activate low
voltage bells, buzzers, horns or any
other audible signal. Ideal for factory
doors, receiving departments, small
office buildings, limited access retail
stores and private homes.
BUTTON
For activating a variety of signals, ideal for limiting space applications. Self-insulating and can be
mounted in any direction. All units include companion magnet. Dimensions: 23⁄16”L x 1⁄2”W x 1⁄2”D
UPC
CODE
DESCRIPTION
TA60
96975
Circuit closed with
magnet engaged
TA61
96976
Make & break
NO and NC
TA62
96977
Circuit open with
magnet engaged
VOLTS
24VAC
12VDC
TA09
96960
8-16VAC
3-6VDC
.95-1.75
1.25-1.80
AMPS
MAX.
TA154
.5
96962
16VAC
3-6VDC
BUTTON
Signals automatically with the opening and closing of doors, windows and transoms. Operates from
pressure in any direction. Non-tilt, non-jamming design. Fits 3⁄4" hole; no need to mortise.
DEVICE
CATALOG
NO.
UPC
CODE
DESCRIPTION
TA44
96995
Normally closed
Push to open
TA45
96996
Normally open
Push to close
TA46
Momentary contact
96997 Push
to make & break
VOLTS
AMPS
MAX.
CATALOG
NO.
Reversible for right or left hand door. Standard surface type used with lock latches with
up to 5⁄8" width and throw. 6" wire leads. Dimensional drawings available on page 138.
CATALOG
NO.
UPC
CODE
TA603L
2
ELECTRIC DOOR SWITCH
TA152
96961
UPC
CODE
DESCRIPTION
INPUT
VOLTAGE
TA1786B
96090
Without conduit
backplate
TA1786CB
96091
With conduit
backplate
Momentary Contacts
4 amps AC/DC @ 12V
4 amps AC, 2 amps DC @ 24V
2 amps AC
1 amp DC @48V
NON-ILLUMINATED PUSH-BUTTONS, UP TO 24VAC
COLOR
96035
Gold
CATALOG
NO.
UPC
CODE
COLOR
SIZE
TA600
96041
Polished
Brass
21⁄4”
(diameter)
TA603
96044
Polished
Brass
13⁄4”
(diameter)
TA631
96088
White
23⁄4 x 7⁄8"
TA635
96047
Ivory, black bar
23⁄4 x 7⁄8"
TA666BK
96048
Black, ivory bar
23⁄4 x 23⁄4
TA602
96043
Polished Brass
13⁄8 x 51⁄4 ”
TA601
96042
Sprayed Brass
2 x 29⁄16 ”
5⁄8"
TA620*
96045
Chrome
5⁄8”
(diameter)
5⁄8"
TA620B*
96046
Brass
5⁄8”
(diameter)
SIZE
13⁄4"
(diameter)
VOLTS
TA631L
12-24V
AC/DC
UPC
CODE
RIM TYPE REMOTE OPENER
DEVICE
CATALOG
NO.
.95-1.75
1.25-1.80
ILLUMINATED PUSH-BUTTONS, UP TO 16VAC
DOOR/WINDOW CONTACTS, ROLLING BALL TYPE
MODEL TA1786B
WEATHERPROOF PUSH-BUTTONS / SOLID CAST BRASS
MAGNETIC SWITCH CONTACTS
CATALOG
NO.
2 13/32"
(61mm)
APPLICATIONS
APPLICATIONS
DEVICE
1 3/16"
(30mm)
96089
White
23⁄4 x 7⁄8"
8-16VAC, 3-6VDC
DOOR TRIP SWITCH
TA656B
96039
Gold
TA215LB
96031
Brass
TA620L*
96037
Chrome
TA620LB*
96038
Brass
15⁄16
x 23⁄4”
BUTTON
For turning lights/signals on or off when doors are opened or closed. Ideal for closets, dark rooms, Signals automatically as door is openend. Commonly used on store doors to announce
storage areas of walk-in refrigeration. Rust resistant steel case with 4 knockouts, antique brass plate. entrance of customers. Mounts on top of door frame. Solid cast brass. Size: 3 x 15⁄8“
Box dimensions: 11⁄4"W x 3 7⁄8"H x 2”D. Plate dimensions: 11⁄4”W
DEVICE
CATALOG
NO.
UPC
CODE
DESCRIPTION
VOLTS
AMPS
MAX.
TA502
96964
Light ON when
door is open
125VAC
250VAC
6
3
DEVICE
CATALOG
NO.
TA236
TA503
96965
Light OFF when
door is open
125VAC
250VAC
6
3
UPC
CODE
96963
VOLTS
12-24VAC
AMPS
MAX.
2
11⁄4 x 2”
(diameter)
(diameter)
*Stainless steel plate to fit TA620 models: Order TA 147-1
TORK ALERT ™
TORK 133
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 134
WARNING LIGHTS
INDUSTRIAL UNITS
WARNING LIGHTS
VEHICULAR UNITS
ORDERING INFO
APPLICATIONS
COLOR
LETTER TO
REPLACE "*"
Red
Amber
Clear
Blue
R
A
C
B
conduit mounting. Full
selection of dome colors,
see "Ordering Info". For
outdoor use. All units must be
mounted vertically with base
at bottom.
DESCRIPTION
TA52*N5 – COMPACT ROTATING BEACON
DEVICE
117VAC
117VAC
TA53*E1 – ROTATING BEACON
Light intensifying reflector rotates arounf a low current 25 watt bulb. Bayonet socket for
easy lamp replacement. Ideal for restricted or dangerous areas.
VOLTS AMPS
90 FPM
Corrosion resistant/Outdoor use
Glass filled polypropylene housing
Acrylic dome
TA47AN5 96161
Tamper resistant dome clamps
Nominal current draw
TA47AR5 96162
91⁄2"H x 81⁄2” diameter
TA47RN5 96061
CATALOG UPC
NO.
CODE
TA52RN5 96063
.9
TA52AN5 96163
240VAC,
60Hz
TA52BN5 96263
DESCRIPTION
VOLTS AMPS
DEVICE
CATALOG UPC
NO.
CODE
TA53RE1 96083
80-90 FPM
360˚ rotation
Dependable belt & turntable design
117VAC .21
Acrylic dome
Nominal current draw
61⁄2”H x 55⁄8” diameter
TA53AE1 96183
TA53AF1 96185
Solid state circuitry in a low profile design. No moving parts means less Maintenance!
TA93-2AN5 97623
TA93-2CN5 96968
TA93-2BN5 97624
Single point shock-mounting. Ideal for use on security or service vehicles.
DESCRIPTION
VOLTS
90-100 FPM
Dependable belt & turntable design
25 watt lamp
Acrylic Dome
Nominal current draw
71⁄2”H x 6” diameter
12VDC
DEVICE
CATALOG UPC
NO.
CODE
DESCRIPTION
VOLTS
75 FPM, 12 watt lamp
12VDC
Quiet belt-drive motor.
Teardrop design fits under windshields.
Includes glare shield, velcro tape
TA54RE1 96087
41⁄2”H x 71⁄2” diameter
TA54AE1 96187
36VDC
24VDC
TA371L*N5 – ROTATING SEALED TWIN BEAMS
TA93-2*N5 – MIDI-STROBE
TA93-2RN5 99622
R
A
TA54*E1 – PORTABLE, MAGNETIC, ROTATING BEACON
Single point shock-mounting. Ideal for use on security or service vehicles.
TA53AG1 96184
DEVICE
Red
Amber
conduit mounting. Full
selection of dome colors,
see "Ordering Info". For
outdoor use. All units must be
mounted vertically with base
at bottom.
TA47*N5 / TA47*R5 – ALL PURPOSE 360° BEACON
CATALOG UPC
NO.
CODE
LETTER TO
REPLACE "*"
1⁄2"
Large parabolic reflector rotates around a 100 wall bulb. Long range beam. Use to indicate
equipment malfunctions, security intrusion, etc.
CATALOG UPC
NO.
CODE
COLOR
APPLICATIONS
1⁄2"
DEVICE
ORDERING INFO
DESCRIPTION
Heavy Duty, double sealed beam, revolving light with 30 watt lamps. Each 35,000 CP bulb
provides long range visibility.
VOLTS AMPS
70-80 FPM
Solid state electronic circuitry
High output 3-4 watt, 3.6 joules
Vertically mounted flash tube
117VAC .04
Snap out socket base for
360˚ Fresnel dome optics
Nominal current draw
6 1⁄2”H x 5 1⁄8” diameter
DEVICE
CATALOG UPC
NO.
CODE
TA371LRN5 96500
DESCRIPTION
TA131D*N5 / TA131D*U1 – DOUBLE FLASH SUPER STROBE
VOLTS AMPS
80-90 FPM
117 VAC
Lexan® dome
Quiet belt drive motor
Anodized aluminum housing with polished
aluminum, non-tarnishing base
Snap lock retaining ring
for quick & economical changeout
91⁄2”H x 8 1⁄2” diameter
.8
Ideal for industrial applications requiring extremely high visibility. One model
covers all popular mounting methods: 1⁄2" pipe, surface, flange, electrical box.
DEVICE
CATALOG UPC
NO.
CODE
TA131DRN5 96510
TA131DAN5 96610
TA131DRU1 96511
TA131DAU1 97611
TA94*N5 – ELECTRONIC STROBE
DESCRIPTION
VOLTS AMPS
120VAC
60 FPM, 7.5 JPF
High intensity 85,000 peak CP
Flashtube Rated at 7000-8000 hrs.
Durable Lexan® housing
10.55”H x 71⁄4” diameter
.2
TA879 – VEHICULAR BACKUP ALARM
Solid state electronic unit. Helps to comply with OSHA and State regulations. Makes
distinctive noise, ideal for extreme variations in background noise
DEVICE
CATALOG UPC
NO.
CODE
TA879
96102
DESCRIPTION
VOLTS
2 sound levels
97 or 87 dB +/- dB at 4ft
Multi-voltage
Water-resistant housing
12 to
48VDC
31.0VDC
High intensity strobe tube with inner fluted lens for maximum brilliance. No moving parts makes
it immune to shock and vibration. Ideal for security alert.
DEVICE
CATALOG UPC
NO.
CODE
DESCRIPTION
VOLTS AMPS
70-80 FPM
Solid state electronic circuitry High
output 3-4 watt, 3.6 joules
Acrylic dome
TA94AN5 97627
117VAC .04
Glass filled polypropylene housing
Suitable for outdoor use
TA94BN5 97628
91⁄2”H x 81⁄2” diameter
TA94RN5 97626
NOTE: "FPM" = Flashes per minute
"JPF" = Joules per flash
For replacement parts and accessories, see page 138.
TORK ALERT ™
TORK 135
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 136
ACCESSORIES,
REPLACEMENT
PARTS
& DIMENSIONS
POWER SUPPLY
UNITS
24 VDC UNITS
TA640
TA606
Red
Amber
Clear
Blue
Green
White
Units provide power to
multiple signaling devices
depending on requirements.
TA606
Regulated and filtered 24VDC up to 600mA. Easy to
use screw terminals, accepts #16-24AWG. No conduit is
required for installation.
RIPPLE
OUTPUT
CURRENT REGULATION VOLTAGE
CATALOG
NO.
UPC
CODE
INPUT
VOLTAGE
OUTPUT
VOLTAGE
TA606
96109
117VAC
24VDC
600mA
TA640
96110
115VAC
24VDC
4A
+/-5%
10mVRMS
TA640
Dual output unit, each providing 2 Amps fo current. If
connected in parallel, will provide up to 4Amps. Circuit
breaker provides input protection.
TRANSFORMERS
UNIT
ORDERING INFO
UPC
CODE
TYPE
TA590
96104
Bell
TA591
96105
Chime
VOLTS-AMPS PRIMARY SECONDARY
(VA)
VOLTAGE
VOLTAGE
5
10
120
120
10
16
Hz
60
60
TA592
96106
Tri-Volt
10-10-20
120
8-16-24
50/60
TA598
96602
Tri-Volt
20-30-30
120
8-16-24
60
TA599
TA1245Y-50
TA1245Y-75
96108
96166
96167
Heavy Duty
Heavy Duty
Heavy Duty
96971
Acrylic Dome – Amber
TA-M1
96138
12VDC Motor
TA53, TA54
TA-B1
96114
Small Drive Belts
TA53, TA54
TA-B2
96115
Large Drive Belts
TA371L
TA-B3
96116
Drive Belts
TA53, TA54
TA-L3
96129
12VDC Bulb
TA53
TA-L4
96130
24VDC Bulb
TA93-2
TA-L6-2
96982
110VAC Xenon Flash Tube
TA52
TA-L8
96134
110VAC Bulb
TA47
TA-L9
96135
110VAC Bulb
TA-L10
96136
110VAC Xenon Flash Tube
TA-L10-1 96981
110VAC Xenon Flash Tube
40
50VA
75VA
120
120/208/240
120/208/240
24
24
24
60
60
60
TA-L12
97625
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
WIRING DIAGRAMS
1/2"
2-7/8"
1-13/16"
TA874 Series
TA-BBSF 97694
TA874 Series
TA-WBBF 97692
Backbox – 4" painted Dawn Mist
Weatherproof Backbox – .5" KOs
4" painted Dawn Mist
Semi-Flush plate – Dawn Mist
3"
3-1/2"
TA-ADR
96111
Acrylic Dome – Red
TA47, TA94
TA-ADA
96311
Acrylic Dome – Amber
TA47, TA94
TA-ADB
96411
Acrylic Dome – Blue
TA52, TA53
TA-D5B
96419
Acrylic Dome – Blue
WIRE
LEADS
11/16"
3/32"
1-3/8"
TA-D6A
96320
Dome – Amber
TA54
TA-D6C
96422
Dome – Clear
TA93, TA94
TA-D7R
96121
Fresnal Dome – Red
TA93, TA94
TA-D7A
96321
Fresnal Dome – Amber
TA-D7B
96421
Fresnal Dome – Blue
TA131D
TA-D8R
96970
4-1/16"
15/16"
3/16" 7/16"
HEAVY DUTY BELLS
6”
10" DIA.
10”
6"
4-1/16" 3-3/8"
3-3/8"
10" DIA.
4-1/16"
3-3/8"
3-3/8"
4-1/16"
3-3/8"
3-1/4"
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
3-3/8"
4-1/16"
3-3/8"
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
4 1/16”
3-3/8"
3-3/8"
3-1/4"
4-1/16"
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
.173 DIA. CSK 80 ° TO 82°
6" 11/32" DIA. – 4 PLACES
TO
4-1/16" 3-3/8"
Acrylic Dome – Red
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
3-1/4"
3-3/8"4-1/16"
3-1/4"
3-1/4"
3-1/4"
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
4”
3-3/8"
10" DIA.
6"
4-1/16"
4-1/16" 3-3/8"
4-1/16"
Fresnal Dome – Clear
TA93, TA94
5/8"
27/32" 23/32"
Dome – Red
TA54
CL
1-9/16"
No. 6 FLAT HEAD
WOOD SCREW
Semi-Flush plate – Red
TA47, TA94
3/32"
7/16"
CL
TA154
1/4"
15/16"
7/32"
1/8"
5/8"
1-1/4"
Replacement switcH
96621
1-1/4"
110VAC Bulb
4-1/16"
TORK 137
NO. 8 FLAT HEAD
WOOD SCREW
TA503SW 96969
TA-D7C
1"
CL
TA503
TA93, TA94
5/8"
1-3/4"
5-7/8"
Replacement switch
96120
1-9/16"
3-5/8"
TA502SW 96966
TA-D6R
3/4"
5-3/8"
TA502
TA54
3/8"
1-3/8"
Backbox
TA-BBSF, TA-WBBF TA-SFPFR 97697
11/32"
2-3/4"
3/32"
TA502-BX 96967
97707
1/8"
1/16"
TA09
TA502
TA-BBSF, TA-WBBF TA-SFPF
1/16"
9/16"
DESCRIPTION
3-3/8"
TORK ALERT ™
11/16"
No. 6 MOUNTING
SCREWS (3)
1/2"
CL
TA-D8A
TA94
APPLICATIONS
CATALOG UPC
NO.
CODE
WIRE
LEADS
CL 1-3/8"
2-1/8"
< Full selection of dome colors.
To designate color, place desired
letter in place of " * "
TA53
TA-94
CATALOG
NO.
3-5/16"
1-3/16"
TA131D
TA371L
Engineered to ensure long
use on bells, buzzers and
chimes.
9/16"
TA152
ORDERING INFO
ORDERING INFO
FEATURES
REMOTE CONTROL DOOR OPENERS
15/16"
APPLICATIONS
LETTER TO
REPLACE "*"
R
A
C
B
G
W
COLOR
DIMENSIONS
4-1/16"
2-7/8"
.173 DIA. CSK 80 ° TO 82°
TO 11/32" DIA. – 4 PLACES
TORK 138
POOL&SPA CONTROLS
PP PANEL SERIES
POOL AND SPA PANELS
WITH TIME SWTICHES
APPLICATIONS
Pumps
Swimming pools
Fountains
Ponds
LISTED
POOL/SPA
CONTROL PANEL
3NZM
PP-100R-P4
ORDERING INFO
PP-20R-2P4
CONTROL
INPUT
CONTROL #2
120VAC
N/A
Rated for 15A, 1⁄2HP @ 120VAC
53011
Mechanical
24 hour timer
Digital
7 day timer
120VAC
N/A
Rated for 15A, 1⁄2HP @ 120VAC
PP-20R
94015
N/A
120/240VAC
N/A
Panel only. Add controls from
page 147 and 148.
PP-20R-P1
53000
P1101-M
120VAC
N/A
PP-20R-P4
53001
P1104-M
240VAC
N/A
DEVICE MOUNTING: Provision for
mounting one or two devices in any
combination accepts toggle, GFCI, X-10 and
UPB type devices in, PP-100R and PP-125R
enclosures.
PP-20R-2P1
53002
P1101-2M
120VAC
PP-20R-2P4
53003
P1104-2M
240 VAC
Included with control
#1 mechanism
Included with control
#1 mechanism
PP-100R
94016
N/A
120/240VAC
TRANSFORMER: Select panels include 120V
input: 100 watt with output 12V/13V or 300
watt with output 12V/13V/14V.
PP-100R-P4
53004
P1104-M
240VAC
PP-100R-P4P1
53005
P1104-M
240VAC
P1101-M
120VAC
PP-100R-2P4
53006
P1104-M
240VAC
P1104-M
240VAC
PP-100R-P4P4FM
53009
P1104-M
240VAC
P1104FM-M
240VAC
PP-125R
94017
N/A
120/240VAC
PP-125R-P4
53007
P1104-M
240VAC
PP-125-2P4
53008
P1104-M
240VAC
P1104-M
240VAC
PP-125R-P4-100X
94018
P1104-M
240VAC
PP-125R-P4-300X
94019
P1104-M
240VAC
PP-10R-M-GFCI
FEATURES
COMBINATION PANEL: The PP panel
series provides a flexible platform to create a
custom pool and spa control at an off the shelf
price. Start with a blank panel and addtimers,
freeze controls, circuit breakers, switches and
outlets for a custom installation. Or select a
pre-assembled timer/panel available in many
popular combinations.
PP-10R: 15 amp timed GFCI protected outlet
with additional GFCI outlet.
PP-20R: 20 amp load center 120-240V, 1/2
circuit breaker base.
PP-100R: 100 amp load center 120-240V,
5/10 circuit breaker base.
PP-125R: 125 amp load center 120-240V,
8/16 circuit breaker base.
CONTROLS: Freeze protection or mechanical
and digital timers are all available with unique
features not found elsewhere in the industry.
Find specification details on pages 147 and 148.
BREAKERS: Listed for Cutler Hammer (BR),
GE (THQL), Murray/Siemens (MP) and Square D
(HOM) (not included).
REVERSIBLE DOOR: Easy-Hinge patented
removable and reversible door. Change from
left to right opening. Solves installation issues
in the field.
WHILE-IN-USE COMPARTMENT: Inside
mounting for two devices with cord exit.
COMPACT 2-IN-1: PP-20R-2P1 and
PP-20R-2P4 includes two timers in a compact
housing. Interlock switch allows second timer
to turn ON only if first timer is in operation.
ENCLOSURE: Metal NEMA 3R with lockable
hasp. See page 153 for dimensions.
NOTE: " " = Indicates freeze protection.
POOL & SPA
CONTROLS
TORK 141
PP-125R-P4-100X
PP-125R-P4
PP-20R-P4
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
CATALOG
NO.
UPC
CODE
PP-10R-M-GFCI
53010
PP-10R-E-GFCI
CONTROL #1
CONTROL
INPUT
ADDITIONAL
INFORMATION
120VAC
Two timers design 50A panel
240VAC
Two timers design 60A panel
Panel only. Add controls from
page 147 and 148.
Add another control
from page 147 and 148.
Timer 2 includes
Fireman Switch
Panel only. Add controls
from page 147 and 148.
Add another control from
page 147 and 148.
Includes 100 watt
Low Voltage Transformer
Includes 300 watt
Low Voltage Transformer
TORK 142
PFP SERIES
1100 SERIES
POOL FREEZE PROTECTION
SWIMMING POOL
TIME SWITCHES
SPECIFICATIONS
SAME ON/OFF TIMES EACH DAY
SWIMMING POOL
TIME SWITCHES
INPUT VOLTAGE: 120 or 208-277VAC,
60Hz (varies by model).
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE:
-40° to 165°F (-40° to +74°C).
APPLICATIONS
APPLICATIONS
POWER CONSUMPTION: 3 watt max.
Pool pumps
Heaters
Lighting
Pumps
Swimming pools
Fountains
Ponds
ENCLOSURE: Lockable hasp. Type varies
by model. See page 153 for dimensions and
additional enclosure information.
FEATURES
SCHEDULING: Minimum ON setting is 20 minutes with a
minimum OFF setting of 75 minutes. Dial accommodates up to
12 pairs of trippers. One pair included.
MANUAL OVERRIDE: Until the next regularly scheduled
ON or OFF automatic operation then resumes.
FEATURES
FREEZE PROTECTION ONLY: Sensor turns on
load when outdoor air temperature drops to user
settable level between 33°F to 42°F. Moving
water prevents costly freeze damage.
TIMERS WITH FREEZE PROTECTION:
Control loads with mechanical or digital timer
with regular on and off schedule. Built-in
temperature sensor forces load on if outdoor air
temperature drops to user settable level between
33°F to 42°F.
COMBINATION PANEL
Combination of timers, freeze protection,
breaker base, and device mountings.
PP-20R: 20 amp load center 120-240V, 1⁄2
circuit breaker base.
PP-100R: 100 amp load center 120-240V, 5⁄10
circuit breaker base.
ORDERING INFO
CATALOG
NO.
UPC
CODE
CONTROL
CONTROL
INPUT
NOTES
CATALOG
NO.
UPC
CODE
PFP2
94035
PFP2-M
240VAC
Freeze protection only
1101
10011
PFP3
94036
PFP3-M
120/240
w/neutral
Freeze protection only
1101-M-IAP
10052
PFP1102
94037
PFP1102-M
240VAC
1104
10014
PFP1103
94038
PFP1103-M
120/240
w/neutral
1104-N
10042
PFPEW1102
94039
PFPEW1102-M
240VAC
1104-O
10017
PFPEW1103
94040
PFPEW1103-M
120/240
w/neutral
1104-M-IAP
10051
PP-20R-F2
94033
PFP1102-M
240VAC
1101FM-N
10043
94034
PFP1102-M &
P1104FM-M
240VAC
Freeze protection
with timer
Freeze protection
with timer
Freeze protection
with Digital timer
Freeze protection
with Digital timer
Freeze protection
with timer
Timer 2 includes
Fireman Switch
1104FM-N
10044
120/240VAC
Thermostat accessory
1101FM-M
10043
1104FM-M
10044
1101D
10028
1104D
10029
1104DF
10032
PP-100R-F2F4FM
PFPT
94028
BEAKERS: Listed for Cutler Hammer (BR), GE
(THQL), Murray/Siemens (MP) and Square D
(HOM) (not included).
WHILE-IN-USE COMPARTMENT: Inside
mounting for two devices with cord exit.
Replacement Trippers
DEVICE MOUNTING: Provision for mounting
one or two devices in any combination accepts
toggle, GFCI, X-10 and UPB type devices.
POOL & SPA
CONTROLS
TORK 143
NOTE: "
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
CONTACT RATINGS
ORDERING INFO
" = Indicates Freeze Protection.
Replacement Motor
INPUT SUPPLY
(VAC) 60Hz
OUTPUT
CONTACTS
ENCLOSURE
TYPE
Metal Indoor
NEMA 1
Mechanism
and
120
SPST
mounting plate
Metal Indoor
208-277
DPST
NEMA 1
®
Indoor/Outdoor
Noryl
208-277
DPST
NEMA 3R
Metal Indoor/Outdoor
208-277
DPST
NEMA 3
Mechanism
and
240
DPST
mounting plate
Noryl® Indoor/Outdoor NEMA
120
SPST
3R with fireman switch
®
Indoor/Outdoor NEMA
Noryl
208-277
DPST
3R with fireman switch
Mechanism with fireman
120
SPST
switch
Mechanism
with fireman
208-277
DPST
switch
Two 1101
Metal Indoor/Outdoor
120
SPST each
NEMA 3R
Two
1104
Metal
Indoor/Outdoor
208-277
DPST each
NEMA 3R
One
1104
Metal
Indoor/Outdoor
NEMA
208-277
One 1104FM
3R
Order #P47 for a pair of ON/OFF trippers
Order #PF48 for a pair of ON/OFF trippers for 1100FM series
120
SPST
TYPE
VOLTAGE
CONTACT
RATING
40A
Resistive
120-277VAC
single phase
120-277VAC
single phase
Tungsten
120VAC
40A
Inductive
120, 277VAC
single phase
20A
Pilot Duty
120-277VAC
1000VA
Motor
120VAC
240VAC
2HP
5HP
General Purpose
40A
#101 (120V) & #201 (208-277V)
TORK 144
DW200B TIMER
CONTACT RATINGS
SPECIFICATIONS
TWO SPEED PUMP CONTROL
TIME SWITCH
TYPE
TIMING ACCURACY: Line Frequency.
INPUT VOLTAGE:
120/208-240/277VAC, 50/60Hz.
Two speed pumps
SVRS device
30A
30A
Ballast
OPERATING TEMPERATURE:
-40°F to 158°F (-40°C to +70°C).
120VAC
277VAC
30A
20A
10A
10A
Tungsten
120-277VAC
15A
2A
POWER CONSUMPTION: 5VA max.
Pilot Duty
120-277VAC
720VA
720VA
ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R
is standard with lockable hasp. See page 153 for
enclosure dimensions and accessories.
Motor Load
120VAC
208-277VAC
1HP
2HP
1HP
2HP
Resistive
28VDC
30A
30A
CH 1
SPDT
SPDT
DWZ100B SERIES
TWO CHANNEL: Two programmable contacts
for independent control of pool equipment and
SVR or coordinated control for two speed pumps.
SCHEDULING: 99 ON & OFF set points allow
individual programs for each day of the week at
a minimum 1 minute apart.
ORDERING INFO
CATALOG
NO.
DW200B
DW200B-0
UPC
CODE
82190
82231
TIMER SUPPLY
(VAC) 60Hz
120/208-240/277VAC
120/208-240/277VAC
SPDT
C
TIMER SUPPLY
NO. OF
CHANNELS
2
2
DRY CONTACTS
(UNPOWERED)
DWZ100B SERIES
TIMER SUPPLY
N
SPDT
SPDT
120
208-240 277
120V
N
120
208-240 277
208-240V
120V
C
NO NC
TIMER SUPPLY
N
L
N
L
277V
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
LOAD
N
CH 1
SPDT
DW200B SERIES
NO NC
AC LINE INPUT
SELECT277V
PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
DAYLIGHT SAVING: Automatic adjustment
(can be omitted) for year-round pools.
DW200B SERIES
LOAD
208-240V
HOLIDAYS: 1 to 24 individual dates for
preprogrammed longer run times for heavy use
times.
NC
24-277VAC
WIRING DIAGRAMS
FEATURES
NO
General Purpose
TERMINAL RANGE: #12 - #16AWG.
APPLICATIONS
CONTACT
RATING
VOLTAGE
120
120V
N
120
C
208-240 277
208-240 277
CH 2
SPDT
C
NO NC
NO NC
C
277V L
208-240V
LOAD
AC LINE INPUT
N
SELECT
PROPER
TERMINALS
277V
AND APPLY ONLY ONE VOLTAGE
C
NO NC
NO NC
L
208-240V
120V
CH 2
SPDT
L
LOAD
L N
LOAD
N
LOAD
N
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
TWO SPEED PUMP WIRING
MANUAL OVERRIDE: Until the next regularly
scheduled ON or OFF, automatic operation then
resumes.
TWO SPEED PUMP WIRING
CLOCK FORMAT: AM/PM or Military time
POWER OUTAGE BACKUP: Permanent
schedule retention when timer is powered
down at the end of the season. Super capacitor
provides 7 days of real time backup.
POOL & SPA
CONTROLS
TORK 145
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
TORK 146
P1100 SERIES
QUICK INSTALL/RELEASE LEVER: For easy installation
and removal when installing into pool panels.
SWIMMING POOL TIMERS, 24 HOUR
ELECTROMECHANICAL
CONTROL
LOAD INDICATOR LAMP
P1100 SERIES
QUICK INSTALL/RELEASE LEVER: For easy installation
and removal when installing into pool panels.
SWIMMING POOL TIMERS, 7 DAY
DIGITAL CONTROL
LOAD INDICATOR LAMP
LARGE LCD DISPLAY
CONVENIENT EXTERNAL ROCKER SWITCH: 3 position
switch: OFF/ON/AUTO. Use switch to turn OFF pump at the
end of pool season.
LARGE "MANUAL" BUTTON: 3 operating modes
available: OFF/ON/AUTO. Using the OFF mode, the pool can
be closed down without disrupting the time settings.
REAL TIME SWITCH FACE: Easy to set and check time.
POWER OUTAGE BACKUP: Battery retains time and
schedule.
CAPTIVE TRIPPERS: 15 minute intervals, no lost trippers.
HEATER CONTACTS: FM suffix includes "Fireman Switch"
to turn off pool heater 20-30 minutes before timer turns OFF.
Contact rates SPST, 15A @120V.
7 DAY PROGRAMMING ONE MINUTE INTERVAL:
Allows for the control of various electrical equipment on a 7
day schedule. 15 schedule weekly programs.
THERMOSTAT: PFP models include built in Freeze
Protection. No extra wiring. Thermostat turns on load at
user settable level between 33°F and 42°F. Moving water
prevents costly freeze damage.
ACCESSORY CONTACT: PF models include extra contact to
accept PFPT Freeze Protection Accessory. Thermostat turns ON
load at user settable level between 33°F adn 42°F. Moving
water prevents costly freeze damage.
TIMER INTERLOCK: Makes one second timer dependant
on operation of another timer.
ORDERING INFO
CATALOG
NO.
RESISTIVE/
UPC INPUT SUPPLY
CODE (VAC) 60Hz CONTACTS INDUCTIVE
RATINGS
HP RATING
PFP2-M
94026
240
DPST
40A
7.5HP @ 240V
PFP3-M
94027
120/240
w/neutral
DPST
40A
3 HP @ 120V
7.5HP @ 240V
P1101-M
10056
120
DPST
40A
3 HP @ 120V
P1101FM-M
10060
120
DPST
40A
3 HP @ 120V
PF1101-M
94020
120
DPST
40A
3 HP @ 120V
PF1101FM-M
94024
120
DPST
40A
3 HP @ 120V
PFP1102-M
94022
240
DPST
40A
7.5HP @ 240V
PFP1103-M
94023
120/240
w/neutral
DPST
40A
3 HP @ 120V
7.5HP @ 240V
P1104-M
10057
240
DPST
40A
7.5HP @ 240V
P1104FM-M
10061
240
DPST
40A
7.5HP @ 240V
PF1104-M
94021
240
DPST
40A
7.5HP @ 240V
PF1104FM-M
94025
240
DPST
40A
7.5HP @ 240V
P1101-2M
10058
120
DPST
40A
2HP @ 120V
P1104-2M
10059
240
DPST
40A
5HP @ 240V
POOL & SPA
CONTROLS
TORK 147
NOTES
Thermostat
only
Thermostat
only
Fireman
Switch
Accepts PFPT
thermostat input
Fireman Switch & Accepts
PFPT thermostat input
Freeze Protection
included
Freeze Protection
included
Fireman
Switch
Accepts PFPT
thermostat input
Fireman Switch & Accepts
PFPT thermostat input
Replacement for
PP-20R-2P1
Replacement for
PP-20R-2P4
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
THERMOSTAT: PFPEW models include built in Freeze
Protection. No extra wiring. Thermostat turns on load at
user settable level between 33°F and 42°F. Moving water
prevents costly freeze damage.
ACCESSORY CONTACT: PFEW models include extra
contact to accept PFPT Freeze Protection Accessory.
Thermostat turns ON load at user settable level between 33°F
and 42°F. Moving water prevents costly freeze damage.
ORDERING INFO
CATALOG
NO.
RESISTIVE/
UPC INPUT SUPPLY
CODE (VAC) 60Hz CONTACTS INDUCTIVE
RATINGS
HP RATING
PEW101-M
82432
120
DPST
40A
3 HP @ 120
PFEW101-M
94029
120
DPST
40A
PFPEW1102-M
94031
240
DPST
40A
PFPEW1103-M
94032
120/240
w/neutral
DPST
40A
Accepts PFPT
thermostat input
protection
7.5HP @ 240V Freeze
included
3 HP @ 120V Freeze protection
7.5HP @ 240V
included
PEW104-M
82442
240
DPST
40A
7.5HP @ 240V
PFEW104-M
94030
240
DPST
40A
Accepts PFPT
7.5HP @ 240V thermostat
input
NOTES
TIMER INTERLOCK: Makes one timer dependant on
operation of another timer.
3 HP @ 120
NOTE: "
" = Indicates Freeze Protection.
WIRING DIAGRAMS
POOL & SPA
JUNCTION BOXES
A
B
C
APPLICATIONS
For installation of underwater pool
lights or low voltage connections.
Solid brass with grounded post and
3 ground terminals for use with
metallic or PVC conduit.
NOTE: "
" = Indicates Freeze Protection.
ORDERING INFO
CATALOG
NO.
UPC
CODE
NPF CONDUIT HUB PIPE INPUT
A/B/C
SIZE
PB-50
94041
1⁄2"
/ 1⁄2" / 1⁄2"
1⁄2"
PB-75
94042
3⁄4"
/ 3⁄4" / 3⁄4"
.3⁄4"
PB-100
94043
3⁄4"
/ 1"/ 3⁄4"
3⁄4"
& 1"
TORK 148
SR-500 & SR-500PS
NEW!
SAFETY VACUUM
RELEASE SYSTEMS
2
1
Of all the protections you can put
between your family and the risk of
entrapment, the best protection is
APPLICATIONS
AT THE SOURCE.
®
A Safety Vacuum Release System (SVRS)
works by monitoring the vacuum on the
suction side of the pool or spa pump. When a
blockage occurs in the main drain or skimmer,
a sudden rise in vacuum will cause the SR-500
and SR-500PS to shut down and activate an
audible alarm. The pump will remain off with
the alarm sounding until manually reset.
Make Your Pool & Spa Safer, Update your
LAYERS OF PROTECTION
Door alarms on doors leading to the pool or spa area
help to alert parents or staff to anyone entering the
pool from the house or building.
Commercial & Residential
Swimming pools and spas
Fountains
Ponds
Any pump size
WARNING ALARM: Multiple audible alarm
capabilities – allows for quicker alert to harmful
situations.
AUXILARY CONTACTS: Accessible extra dry
contact – auxiliary equipment can be added.
EQUIPMENT PROTECTION: Low vacuum
sensing - (prevents cavitations or running the
pump dry, eliminating costly equipment failure).
SCHEDULING: Programmable 24 hour timer,
or as stand-alone SVRS working in conjunction
with existing pool controller.
POOL & SPA
CONTROLS
TORK 149
Remote alarms linked to the Safety Vacuum Release
System (SVRS) alert parents or attendants when the
SVRS is activated, indicating that someone in the pool
may need help.
ORDERING INFO
FEATURES
PROTECTION:
• Provides an important layer of protection,
reducing entrapment risk.
• Turns off pump in milliseconds upon detecting
sudden vacuum change.
• Vacuum monitored 128 times per second,
rapid response and accurate readings.
• Power monitored 50/60 times per second,
insures continuous power detection.
• Newest state-of-art NEC microprocessor
technology-- guaranteed reliability and
performance.
OUTSIDE
THE POOL AREA
Keep children from
accessing the pool
or spa when
unattended
DOOR ALARMS
1
POWER OUTAGE BACKUP: Insures
settings and reading will be saved, 30 minute
rapid recharge.
INPUT SUPPLY DRY CONTACTS
(VAC) 60Hz
(UNPOWERED)
CATALOG
NO.
UPC
CODE
SR-500
95425
120/240
DPST
SR-500PS
95426
120/240
DPST
MAINTENANCE OVERRIDE: 30 minute
maintenance override - (for pool or spa
service).
BUILT-IN DIAGNOSTICS: Displays
error codes, prevents guessing during
troubleshooting.
EASY RETROFIT: Integrates with common
existing timer box Trouble free installation, no
pipes to cut or glue.
COMPLIANCE: ASME/ANSI 112.19.17 as
required by the International Building Codes
(IBC) and the International residential Codes
(IRC). Meets all current codes and standards
for
SVRSs on new and existing pools and spas.
ENCLOSURE: Plastic Indoor/Outdoor NEMA
3R with lockable hasp. See page 153 for
dimensions and additional information.
2
Restrict access to a pool or spa by surrounding the
area with fencing that is equipt with a self-closing,
self-latching gate closure. Utilize gate latches that
are adjustable, magnetically operated as well as key
lockable.
CONTACT RATINGS
TYPE
General Purpose
Motor
VOLTAGE
120VAC
240VAC
120VAC
240VAC
FENCE & GATE
3
An emergency STOP button allows parents or attendants in the
area to immediately and easily shut down the pump system in
the event of entrapment.
INSIDE
THE POOL AREA
Minimize the
risk of entrapment
injuries or drowning
CONTACT
RATING
20A
3HP
EMERGENCY STOP
4
SVRS
The SVRS automatically shuts down the vacuum pump when
sensing a rise in vacuum pressure – in some cases, reacting to
potential entrapment conditions in LESS THAN ONE SECOND!
Audible alarms linked to the SVRS alert those nearby to a
potential entrapment.
SVRS should meet or exceed ASME/ANSI A112.19.17 standards
in order to comply with IRC and IBC codes.
5
3
DRAIN COVERS
Minimize potential entrapments or “Differential Hold Down
Forces,” thereby minimizing the potential for a swimmer to
be entrapped.
4
5
Anti-entrapment drain covers should meet or exceed ASME
and ANSI A112.19.8 2007 and 2007 Federal Pool & Spa
Safety Act and have a Certified Safe Flow Rating. Many
compliant drain covers are easily retrofitted to existing drains.
ALL ITEMS AVAILABLE FROM NSi/TORK!
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
More details available in our Safety Products catalog and Layers of
Protection brochure, ask your sales representative for more information.
ANTI-ENTRAPMENT
DRAIN COVERS
SELF-LATCHING
GATE CLOSURES
& SELF-CLOSING
GATE HINGES
NEW!
NEW!
640-475XV
TCA1-MK2
DS360M
TCHD1ARP-MK2
AV20X20 & AV26X26
FEATURES
DS360M DRAINSAFE
• Designed for use with suction outlet sumps up
to 8" in size, will retrofit smaller 5” sumps using
additional knockouts.
• Certified Safe flow of 123 GPM.
• ASME/ANSI A112.19.8 2007 Standard Compliant.
DS12X12P DRAINSAFE
• Designed to retrofit Pentair style frames, and
functions on dual drain as well as single suction
outlets.
• Certified Safe flow of 250 GPM @ 1.5 FPS.
• ASME/ANSI A112.19.8 2007 Standard Compliant.
DS12X12H DRAINSAFE
• Designed to retrofit Hayward style frames, and
functions on dual drain as well as single suction
outlets.
• Certified Safe flow of 250 GPM @ 1.5 FPS.
• ASME/ANSI A112.19.8 2007 Standard Compliant.
FEATURES
DS12X12P
DS12X12H
ORDERING INFO
CATALOG
NO.
UPC
CODE
DESCRIPTION
SURFACE AREA
(SQ.IN)
RETROFIT
FRAME
DS360M
95431
Drainsafe Anti-Entrapment
Type Suction Outlet Cover
27
N/A
DS12X12P
95429
53
Pentair
DS12X12H
95430
53
Hayward
640-475XV
95432
159.6
18 x 18
AV20X20
95433
AV26X26
95434
Drainsafe 12 x 12" Anti-Entrapment
Type Suction Outlet Cover
Drainsafe 12 x 12" Anti-Entrapment
Type Suction Outlet Cover
Waterway 18 x 18"
Anti-Entrapment Drain Cover
Eureka 20 x 20"
Anti-Entrapment Drain Cover
Eureka 26 x 26"
Anti-Entrapment Drain Cover
640-475XV WATERWAY
• Designed for single and multiple drain use, the
640-475XV works on dual drain as well as single
suction outlets.
• Minimizes “Differential Hold Down Forces” of
dual drain systems.
• Certified Safe flow rate of 540 GPM @ 1.09 FPS.
73.6
108.9
12 x 12
(9 x 9 minimum)
18 x 18
(12 x 12 minimum)
MAGNA•LATCH GATE CLOSURES
MagnaLatch quality latches are self-latching with
permanent magnets which never lose power, for
safer, child-resistant security for your swimming
pool gate. The Top Pull model can be mounted so
the release knob reaches the minimum code height,
typically 54", on a shorter gate. It's adjustable for
when the gate gets out of alignment. The Vertical
Pull model is designed for gates and fences that
are 60” or more in height.
TRU•CLOSE GATE HINGES
TruClose® hinges are designed so the residential
homeowner can quickly and easily adjust tension to
support a 375lbs gate load and self-closes up to a
55lb gate, for the ultimate safety around pools and
other areas requiring self-closing gates. Hinges
are rust-free and are self-lubricating. Regular duty
and heavy duty models available.
FENCE
MATERIAL
PACKAGING
AVAILABLE
CATALOG
NO.
UPC
CODE
DESCRIPTION
MLTPS2BGA
95439
MagnaLatch Top Pull Gate Latch
MLTPRP
95445
MLVPS2BGA
95440
MLVPRP
95444
MLS2RPAKA
95446
Round Post Adapter Kit
Wholesale
MLSPACER
95447
MagnaLatch Gap Spacer
Retail
Wholesale
MagnaLatch Top Pull Gate Latch, 2" Gap
Retail
Spacer included
Wholesale
MagnaLatch Vertical Pull Gate Latch
MagnaLatch Vertical Pull Gate Latch, 2"
Retail
Gap Spacer included
REGULAR DUTY MODELS
TCA1RP-MK2
98018
TruClose® Regular Range Gate Hinge
Metal
Retail
TCA1-MK2
98026
TruClose® Regular Range Gate Hinge
Metal
Wholesale
TCA3RP-MK2
98019
TruClose® Regular Range Gate Hinge
Vinyl, Wood
Retail
TCA3-MK2
98027
TruClose® Regular Range Gate Hinge
Vinyl, Wood
Wholesale
TCAMA2RND
98024
TruClose® Regular Range Gate Hinge,
Round frames
adjustable gap
Wholesale
HEAVY DUTY MODELS
DS-MR
DS-AA
TORK 151
MLTPS2BGA
POOL & SPA SAFETY
ACCESSORIES
AV20X20 & AV26X26 EUREKA
• Eureka drain covers unique grating system is
designed for new construction and retrofit, to add
protection from entrapment.
• ASME/ANSI A112.19.8 2007 Standard Compliant.
• Certified Safe flow rate of 223 GPM (20x20),
495 GPM (26x26).
POOL & SPA
CONTROLS
ORDERING INFO
TCHD1ARP-MK2
98020
TruClose® Heavy Duty
Metal
Retail
TCHD1AL2-MK2
98021
TruClose® Heavy Duty, with 2 legs
Metal
Wholesale
TCHD2RP-MK2
98022
TruClose® Heavy Duty
Vinyl, Wood
Retail
TCHD2L2-MK2
98023
TruClose® Heavy Duty, with 2 legs
Vinyl, Wood
Wholesale
SAFETY ACCESSORIES
SR-RA
SR-ESB
SR-RA
95437
Remote Alarm
SR-ESB
95438
Emergency Stop Button
DS-AA
95435
Drainsafe Masonry Anchor Kit - for
DS360M
DS-MR
95436
Drainsafe Mud Rings, Universal Fit
ALL ITEMS AVAILABLE FROM NSi/TORK!
A DIVISION OF
NSi INDUSTRIES, LLC
USA • 800.321.5847 • www.nsiindustries.com
More details available in our Safety Products catalog and Layers of
Protection brochure, ask your sales representative for more information.
TORK 152
ENCLOSURES
ENCLOSURES
STANDARD
FOR MODELS
METAL INDOOR NEMA 1
ENCLOSURE #68229
STANDARD
FOR MODELS
METAL INDOOR/OUTDOOR NEMA 3
MODEL #9006
STANDARD
FOR MODELS
METAL INDOOR NEMA 1
ENCLOSURE #63016-1
MECHANISM &
MOUNTING BRACKET #62153-1
MODELS
1101
7120
TZ220L-0
TZ300L-0
TZ220L
TW220L
Use Bracket #64039
1102
7122
TZ300L-0
T920L-0
TZ300L
TW300L
W100
W120
W220
3-5/8 "
W222
3-1/16"
1103
8001
W300
T920L
W200
1104
8004
W302
T930L
W202
1101FM
8061
W300L
TW222L
1104FM
8121
W302L
TW302L
7100
8301
#62158 "E" DOOR
7102
8601
T920L-E
7200
8602
TW220L-E
T930L-0
7202
TU40-Y
1101-7
EW201-Y
TRP400
7220
1847AZL LDS-A
7222
8007
7200L
8007L
7202L
8007V
7120L
8150
1847A
8150U
1848A
8007U
1849A
8007VL
1847AZ
8008
1847AL
8008L
STANDARD
FOR MODELS
2-1/2"
ELC72PC/120
ELC72PC/208-240
11-1/2"
12"
W302
DLC400BP
LDSH-A
STANDARD
FOR MODELS
DLC400BP
12-1/4"
T930L-E
MECHANISM
ONLY
MECHANISM
MECHANISM
WITH BRACKET WITH BRACKET
#62153-1
#64039
4"
1101NC DGLC100A-NC
1101-M-IAP
7200
1103NC DGLC200A-NC
1104-M-IAP
7202
1104NC
1102
7120
8001-NC
1103
7122
METAL INDOOR NEMA 1
ENCLOSURE #70100
DG SERIES
W200
W222L
E101PB
1103-N
W202
1847AW
E Series
W120
TU40
7-5/8"
1847AWL
DTU40
EW Series
11-7/8"
W220
DG Series DZS Series
TERMINAL BLOCK
MECHANISM ONLY
GROUND
4-9/16 "
SCREW
MECHANISM & BRACKET
CLEARANCE HOLE
FOR GROUND SCREW
4-9/16 "
MODELS
5441
6-5/8 "
5-1/16"
4-9/16 "
7-5/8"
BRACKET
4-9/16 "
MECHANISM ONLY
4-9/16 "
3-5/8 "
TERMINAL BLOCK
MECHANISM & BRACKET
EWZ101-MB
2-3/32 "
E, EWZ, EH
SERIES
EWZ103-MB
11-1/2"
BRACKET
SMC-3D
4-9/16MECHANISM
"
3-5/8
"
&
BRACKET
6-5/8 "
EWZ201-MB
6-5/8 "
MECHANISM & BRACKET
3-3/8"
MECHANISM
ONLY
EWZ120-MB
8-5/16"
3-1/16 "
2-1/2"
1-15/16 "
14-1/8"
12-3/4"
3-1/2"
TERMINAL BLOCK
MECHANISM & BRACKET
DG SERIES
WIRING COMPARTMENT
10-1/8"
WITH MOUNTING
BRACKET
#64039
STINGL
3/4" or 1" KO
7-5/8"
6-5/8 "
3-5/8 "
1/2" or 3/4" KO
3-1/16"
Note: Indoor Enclosure Only
11-1/2"
TERMINAL BLOCK
TERMINAL BLOCK
9000PC
3-1/16"
1-15/16 "
DZS, DTS,
DZM, DW,
DWZ
SERIES
3-1/4"
STANDARD
FOR MODELS
W400A
1101D
1101DF
W402A
1114D
1114DF
W400AL
1104D
1104DF
METAL DUPLEX INDOOR/OUTDOOR
NEMA 3 MODEL #9004L
4-9/16 "
4-9/16 "
6-5/8 "
EW103B-C EW120B-C
TERMINAL BLOCK
3-1/16 "
DZM, DW,
DWZ BRACKET
SERIES
6-5/8 "
TERMINAL BLOCK
1-15/16 "
MECHANISM & BRACKET
DZS, DTS,
MECHANISM ONLY
PLASTIC INDOOR/OUTDOOR
NEMA 3R WITH CLEAR WINDOW
MODELS
4-9/16 "
TERMINAL BLOCK
1-15/16 "
MECHANISM & BRACKET
8-5/16"
STANDARD FOR MODELS
SMC-3D
3-1/16 "
MECHANISM & BRACKET
E, EWZ,
3-3/8"
EH
SERIES
MECHANISM
ONLY
LC200M
MODELS
TERMINAL BLOCK
4-17/32 "
1102-M
1103-M
1104-M
SMC-3D
8001-LC/WB
DTWH40
8601
8121
8602
8061
5-1/2"
3.4000"
EJWT
E500T
MECHANISM & BRACKET
3-13/32 "
E501T
7 1/2” 7 1/ ”
2
1-13/16 "
9-3/8"
7-1/2"
PP-20RPP-20R
PP-20R-P1
PP-20R-P1
PP20R-P4
PP20R-P4
PP-20R-2P1
PP-20R-2P1
PP-20R-2P4
PP-20R-2P4
MECHANISMS/BRACKETS
5-37/64 "
3-1/16 "
STANDARD
FOR MODELS
STANDARD
FOR MODELS
1101-O
1104-O
7302, L, Z, ZL 8001U-0
1102-0
7200-O
1103-0
7202-O
8007-0
POOL PANEL SERIES
4"
MECHANISM
ONLY
METAL INDOOR/OUTDOOR NEMA 3
MODEL 9000B – SUFFIX "O"
LC200M MOUNTING
WITH BRACKET
MODELS
4-11/16"
MECHANISM
WITH BRACKET
LC200M
LC200M
MECHANISM & BRACKET
4-17/32 "
3-9/32 "
LDS
LDSH
MECHANISM & BRACKET
LC200M
3-13/32 "
LDS SERIES MOUNTING
WITH BRACKET
MODELS
3.4000"
MECHANISM & BRACKET
LDS
1-13/16 "
2-1/8 "
4-17/32 "
LDSH
3-9/32 "
3.4000"
LDS
LDSH
MECHANISM & BRACKET
3-13/32 "
13 3/8” 13 3/ ”
8
PP-100R
PP-100R
PP-100R-P4
PP-100R-P4
PP-100R-P1P4
PP-100R-P1P4
PP-100R-2P4
PP-100R-2P4
PP-100R-P4P4FM
PP-100R-P4P4FM
17 3/4” 17 3/ ”
4
SHOWN WITH
SNAP TRACK
3-3/8"
4 5/8” 4 5/ ”
8
4 1/4” 4 1/ ”
4
4"
7 1/2”
7300, L, Z, ZL 8001-0
8007U-0
4-11/16"
11”
3-3/4"
MECHANISM & BRACKET
8301
3-1/16"
11”
E502T
#64039/62153-1/65447
5-13/16 "
TERMINAL BLOCK
EWJT & E500T SERIES
ENCLOSURE
SR-500PS
3-1/2"
4-9/16"
1-15/16 "
7000 Series
1847A, Z
1848A
3-9/32 "
STINGL SVRS
ENCLOSURE
WITH MOUNTING
BRACKET
#62153-1
2-1/8 "
1101-M
MECHANISM & BRACKET
LDS
LDSH
MECHANISM & BRACKET
MECHANISM & MOUNTING
BRACKET #65446
6-5/8 "
4"
MODELS
SR-500
BRACKET
6-5/8 "
TERMINAL BLOCK
3-1/16 "
ADAPTER
MECHANISM & BRACKET
PLATE
4-9/16 "
MECHANISM ONLY
5-1/16"
NEMA 1 ENCLOSUREE, EWZ, EH
SERIES
METAL INDOOR/OUTDOOR
NEMA 3
MODEL 9000A – SUFFIX "0"
ELC712
1/2" or 3/4" KO
3/4" or 1" KO
2-3/32 "
6-5/8 "
ELC78
4-3/16"
8-3/4"
1/4"
MOUNTING
HOLE
W222
METAL INDOOR NEMA 1
ENCLOSURE FOR W400 SERIES
ELC78 & ELC712
ENCLOSURE
5401 ENCLOSURE
BRACKET
4-11/16"
DWZ Series
4"
12"
3-1/16 "
1-15/16 "
EWZ SERIES
MECHANISM ONLY
EWZ Series
DZM Series
STANDARD
FOR MODELS
TERMINAL BLOCK
9000P
1102-N
SMC-3D
EW Series
PLASTIC INDOOR/OUTDOOR
NEMA 3R #9000P
MODELS
7120Z, ZL
DW Series
E Series
7102
10"
5441 and 5440 REMOTE CONTACTORS
7202Z, ZL
DTS Series
7100
6-5/8 "
1104-N
18"
6-5/8 "
3-3/8"
W220L
BRACKET
3-5/8 "
4"
70100
W100
8001-N
4-9/16 "
12"
DWZ
SERIES
1101-N
8001U-N
MECHANISM & BRACKET
2-3/32 "
ELC74
ENCLOSURE
ELC74
9/32"
MOUNTING HOLES
TRP800
6-5/8 "
DZS, DTS,
7200Z, ZL
7122Z, ZL
4-9/16 "
4"
12"
TRP800
TRP 800 (GROUP OF 8)
9/32"
MOUNTING HOLES
IAP
BRACKET
MECHANISM ONLY
DG SERIES
INTERMATIC ADAPTER PLATE
EWZ SeriesDZM, DW,
STANDARD
FOR MODELS
10"
TRP800
NORYL® & LEXAN®
INDOOR/OUTDOOR
NEMA 3R MODEL #9000NC
14-1/4"
NORYL® INDOOR/OUTDOOR
NEMA 3R MODEL #9000N
ELC72PC/277
18"
STANDARD
FOR MODELS
DLC400BP
9/32"
MOUNTING HOLES
ELC71PC/277
EW130B-Y EW120B-Y
METAL INDOOR NEMA 1
ENCLOSURE #63100
ELC71 & ELC72 SERIES
ENCLOSURE
ELC71PC/120
ELC71PC/208-240
3-1/2"
TRP 400 (GROUP OF 4)
STANDARD
FOR MODELS
TRP 800 (GROUP OF 8)
9/32"
MOUNTING HOLES
TRP402
7-5/8"
Use Bracket #62153-1
W300
TRP400
TRP 400 (GROUP OF 4)
PP-20R
PP-20R-P1
PP20R-P4
PP-20R-2P1
PP-20R-2P4
7 1/2”
PP-20R
PP-20R-P1
PP20R-P4
PP-20R-2P1
PP-20R-2P4
1-13/16 "
11”
13 3/8”
13 3/8”
6 1/8” 6 1/ ”
8
12 3/4” 12 3/ ”
4
11”
PP-100R
PP-100R
PP-100R-P4
PP-100R-P4
PP-100R-P1P4 PP-100R-P1P4
PP-100R-2P4 PP-100R-2P4
PP-100R-P4P4FM
PP-100R-P4P4FM
PP-125R
PP-125R
PP-125R-P4
PP-125R-P4
PP-125R-2P4
PP-125R-2P4
PP-125R-P4-100X
PP-125R-P4-100X
PP-125R-P4-300X
PP-125R-P4-300X
17 3/ ”
17 3/ ”
4
4
PP-10R-M-GFCI
PP-10R-M-GFCI
PP-10R-E-GRCI
PP-10R-E-GRCI
20 3/4” 20 3/ ”
4
9 3/4” 9 3/ ”
4
2-1/8 "
DZS100BP-0 DZS200BP-0
DZS200BP DW200B-0
DZM200BP-0
5-13/16 "
5-37/64 "
5-13/16 "
5-37/64 "
5401
4 1/4”
SHOWN WITH
SNAP TRACK
4 5/8”
4 1/4”
4 5/8”
4 5/8” 4 5/ ”
8
4 1/2” 4 1/ ”
2
SHOWN WITH
SNAP TRACK
12 3/4”
12 3/4”
PP-125R
PP-125R
6 1/8”
6 1/8”
TORK 153
PP-10R-M-GFCI PP-10R-M-GFCI
TORK 154
ALPHANUMERIC INDEX
ALPHANUMERIC INDEX
1101 . . . . . . . . . . . . . . . . . . . . . . . . . 31, 144
2104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
652A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
8001U-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C512HH . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZS100BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65
1101-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
654A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
8004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C515M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZS200BP . . . . . . . . . . . . . . . . . . . . . . . . . . 65
1101D . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
2115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
655D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
8007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C530M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZS200BP-12 . . . . . . . . . . . . . . . . . . . . . . . 65
1101FM-M . . . . . . . . . . . . . . . . . . . . . . . . 144
2116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
701A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
8007L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C560M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZS200BP-24 . . . . . . . . . . . . . . . . . . . . . . . 65
1101FM-N . . . . . . . . . . . . . . . . . . . . . . . . . 144
2117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
701AA . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
8007-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C560MH . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZS200BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65
1101-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2223 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
711A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
8007U . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
D1060LA . . . . . . . . . . . . . . . . . . . . . . . . . . 104
DZS400BP . . . . . . . . . . . . . . . . . . . . . . . . . 65
1101-M-IAP . . . . . . . . . . . . . . . . . . . . 31, 144
2224 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8007U-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
D1060M . . . . . . . . . . . . . . . . . . . . . . . . . . 104
DZS400BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65
1101-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2421 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8007V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
D1060MW . . . . . . . . . . . . . . . . . . . . . . . . . 104
E101B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1101-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8007VL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
D212H . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
E101PB . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1101-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7120L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
D212HA . . . . . . . . . . . . . . . . . . . . . . . . . . 104
E103B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7120Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
8008L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
D212HW . . . . . . . . . . . . . . . . . . . . . . . . . . 104
E120B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1102-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7120ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
8061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
DG100A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
E201B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1102-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
401A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
7122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
DG100A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
E500T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1102-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
402A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
7122ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
8301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
DG180A . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
E501T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
403A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
7200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
DG200A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
E502T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1103-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
405A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
7200L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
90058-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
DG280A . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
EJWT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1103-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
422A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
7200-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A502H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DG280A-24 . . . . . . . . . . . . . . . . . . . . . . . . . 85
ELC712 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
1103-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
454D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
7200Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A502HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGLC100A-NC . . . . . . . . . . . . . . . . . . . . . . . 79
ELC71PC/120 . . . . . . . . . . . . . . . . . . . . . . . 73
1103-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
455D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
7200ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A502HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGLC200A-NC . . . . . . . . . . . . . . . . . . . . . . . 79
ELC71PC/208-240 . . . . . . . . . . . . . . . . . . . 73
1104 . . . . . . . . . . . . . . . . . . . . . . . . . 31, 144
457Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
7202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A506H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGM100A . . . . . . . . . . . . . . . . . . . . . . . . . . 63
ELC71PC/277 . . . . . . . . . . . . . . . . . . . . . . . 73
1104D . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
460D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
7202L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A506HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGM100A-Y . . . . . . . . . . . . . . . . . . . . . . . . 63
ELC72PC/120 . . . . . . . . . . . . . . . . . . . . . . . 73
1104DF . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
5001M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7202-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A506HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGS100A . . . . . . . . . . . . . . . . . . . . . . . . . . 85
ELC72PC/208-240 . . . . . . . . . . . . . . . . . . . 73
1104FM-M . . . . . . . . . . . . . . . . . . . . . . . . 144
5004M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7202Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A512H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGS100A-12 . . . . . . . . . . . . . . . . . . . . . . . . 85
ELC72PC/277 . . . . . . . . . . . . . . . . . . . . . . . 73
1104FM-N . . . . . . . . . . . . . . . . . . . . . . . . . 144
5007M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7202ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A512HH . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGS100A-24 . . . . . . . . . . . . . . . . . . . . . . . . 85
ELC74 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
1104-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5008M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A512HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGU100A-Y . . . . . . . . . . . . . . . . . . . . . . . . . 79
ELC78 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
1104-M-IAP . . . . . . . . . . . . . . . . . . . . 31, 144
5021M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7220L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A512HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGUM100A . . . . . . . . . . . . . . . . . . . . . . . . . 79
ELS-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
1104-N . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
5024M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7222 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A515M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGUM100A-Y . . . . . . . . . . . . . . . . . . . . . . . 79
EPC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
1104-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5026M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7222L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A515MA . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DIN100B . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
EPC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
1104-O . . . . . . . . . . . . . . . . . . . . . . . . 31, 144
5231 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A515MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DIN200B . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
EPC-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
1847A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5237 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7300L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A515MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105
DLC400BP . . . . . . . . . . . . . . . . . . . . . . . . . . 81
EPC-LC . . . . . . . . . . . . . . . . . . . . . . . . . . 73, 75
1847AL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
7300Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A515MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DS12X12H . . . . . . . . . . . . . . . . . . . . . . . . 151
1847AW . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5403 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7300ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A530M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DS12X12P . . . . . . . . . . . . . . . . . . . . . . . . . 151
EW101B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
EW103B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1847AWL . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5404 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A530MA . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DS360M . . . . . . . . . . . . . . . . . . . . . . . . . . 151
EW103B-C . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1847AZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5404-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7302L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A530MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DS-AA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
EW103B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1847AZL . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7302Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A530MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105
DS-MR . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
EW120B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1848A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5441 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
7302ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A530MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DTS100B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
EW120B-C . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
73866 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
A560M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DTS200B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
EW120B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2000-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
803B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
A560MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DTS400B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
EW201B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2000-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5500-OC . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5737TM . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
806B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
A560MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105
DTU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
EW201B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5737TZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
806D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
A560MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
EWZ101 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
601A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
8001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
AV20X20 . . . . . . . . . . . . . . . . . . . . . . . . . 151
DW200B . . . . . . . . . . . . . . . . . . . . . . . . . . 145
EWZ101-MB . . . . . . . . . . . . . . . . . . . . . . . . 61
2005A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
602A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
8001-LC/WB . . . . . . . . . . . . . . . . . . . . . . . . 37
AV26X26 . . . . . . . . . . . . . . . . . . . . . . . . . . 151
DW200B-O . . . . . . . . . . . . . . . . . . . . . . . . 145
EWZ103 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2007A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
611A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
8001-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C412H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
EWZ103-MB . . . . . . . . . . . . . . . . . . . . . . . . 61
2008A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
611D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
8001-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C460M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DWZ100B . . . . . . . . . . . . . . . . . . . . . . . . . . 69
EWZ120 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
621D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
8001-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C502H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZM200BP . . . . . . . . . . . . . . . . . . . . . . . . . 71
EWZ120-MB . . . . . . . . . . . . . . . . . . . . . . . . 61
2022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
631D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
8001U . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C506H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZM200BP-O . . . . . . . . . . . . . . . . . . . . . . . 71
EWZ201 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
640-475XV . . . . . . . . . . . . . . . . . . . . . . . . 151
8001U-N . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C512H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZS100BP . . . . . . . . . . . . . . . . . . . . . . . . . . 65
EWZ201-MB . . . . . . . . . . . . . . . . . . . . . . . . 61
TORK 155
TORK 156
ALPHANUMERIC INDEX
ALPHANUMERIC INDEX
HPS30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
PFP2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
T920L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TA503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA93-2RN5 . . . . . . . . . . . . . . . . . . . . . . . . 135
TCHD1ARP-MK2 . . . . . . . . . . . . . . . . . . . . . 152
LC200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
PFP2-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147
T920L-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TA503SW . . . . . . . . . . . . . . . . . . . . . . . . . 138
TA94AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TCHD2L2-MK2 . . . . . . . . . . . . . . . . . . . . . . 152
LC200M . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
PFP3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
T920L-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TA52AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TA94BN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TCHD2RP-MK2 . . . . . . . . . . . . . . . . . . . . . . 152
LCS115M . . . . . . . . . . . . . . . . . . . . . . . 75, 112
PFP3-M . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
T930L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TA52BN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TA94RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TRP-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
LDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
PFPEW1102 . . . . . . . . . . . . . . . . . . . . . . . 143
T930L-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TA52RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TA-ADA . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TRP-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
LDS-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
PFPEW1102-M . . . . . . . . . . . . . . . . . . . . . . 148
T930L-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TA53AE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TA-ADB . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TRP400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
LDSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
PFPEW1103 . . . . . . . . . . . . . . . . . . . . . . . 143
TA09 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA53AF1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TA-ADR . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TRP402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
LDSH-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
PFPEW1103-M . . . . . . . . . . . . . . . . . . . . . . 148
TA1245Y-50 . . . . . . . . . . . . . . . . . . . . . . . 137
TA53AG . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TA-B1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TRP800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
MLS2RPAKA . . . . . . . . . . . . . . . . . . . . . . . . 152
PFPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
TA1245Y-75 . . . . . . . . . . . . . . . . . . . . . . . 137
TA53RE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TA-B2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TRP802 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
MLSPACER . . . . . . . . . . . . . . . . . . . . . . . . . 152
PP-100R . . . . . . . . . . . . . . . . . . . . . . . . . . 141
TA131DAN5 . . . . . . . . . . . . . . . . . . . . . . . 136
TA54AE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TA-B3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TRP-U . . . . . . . . . . . . . . . . . . . . . 79, 112, 116
MLTPRP . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
PP-100R-2P4 . . . . . . . . . . . . . . . . . . . . . . 141
TA131DAU . . . . . . . . . . . . . . . . . . . . . . . . 136
TA54RE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TA-B-8332 . . . . . . . . . . . . . . . . . . . . . . . . . 132
TU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
MLTPS2BGA . . . . . . . . . . . . . . . . . . . . . . . . 152
PP-100R-F2F4FM . . . . . . . . . . . . . . . . . . . . 143
TA131DRN5 . . . . . . . . . . . . . . . . . . . . . . . 136
TA5508H-G1 . . . . . . . . . . . . . . . . . . . . . . . 127
TA-BBSF . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TU40-Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
MLVPRP . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
PP-100R-P4 . . . . . . . . . . . . . . . . . . . . . . . 141
TA131DRU1 . . . . . . . . . . . . . . . . . . . . . . . 136
TA590 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TA-B-KHD-1000-PP . . . . . . . . . . . . . . . . . . 131
TW-220L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
MLVPS2BGA . . . . . . . . . . . . . . . . . . . . . . . . 152
PP-100R-P4P1 . . . . . . . . . . . . . . . . . . . . . . 141
TA152 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA591 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TA-B-KHD-120VAC . . . . . . . . . . . . . . . . . . 131
TW-220L-E . . . . . . . . . . . . . . . . . . . . . . . . . 47
OSC10U . . . . . . . . . . . . . . . . . . . . . . . . . . 114
PP-100R-P4P4FM . . . . . . . . . . . . . . . . . . . 141
TA154 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA592 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TA-B-KHS-1000-PP . . . . . . . . . . . . . . . . . . 131
TW-222L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
OSC12PL . . . . . . . . . . . . . . . . . . . . . . . . . . 112
PP-10R-E-GFCI . . . . . . . . . . . . . . . . . . . . . . 141
TA1786B . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA598 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TAC210W . . . . . . . . . . . . . . . . . . . . . . . . . 129
TW-300L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
OSC15PLS . . . . . . . . . . . . . . . . . . . . . . . . . 111
PP-10R-M-GFCI . . . . . . . . . . . . . . . . . . . . . 141
TA1786CB . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA599 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TAC212WL . . . . . . . . . . . . . . . . . . . . . . . . 129
TW-302L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
OSC20U . . . . . . . . . . . . . . . . . . . . . . . . . . 114
PP-125-2P4 . . . . . . . . . . . . . . . . . . . . . . . 141
TA1880 B . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TAC212WS . . . . . . . . . . . . . . . . . . . . . . . . . 129
TZ-220L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSC5PL . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
PP-125R . . . . . . . . . . . . . . . . . . . . . . . . . . 141
TA1880 G . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D5B . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TZ220L-O . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSC5U . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
PP-125R-P4 . . . . . . . . . . . . . . . . . . . . . . . 141
TA1882 B . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D6A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TZ-222L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSCS20UP . . . . . . . . . . . . . . . . . . . . . . . . . 113
PP-125R-P4-100X . . . . . . . . . . . . . . . . . . . 141
TA1882 G . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA602 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D6C . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TZ-300L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSWS9P-120 . . . . . . . . . . . . . . . . . . . . . . . 110
PP-125R-P4-300X . . . . . . . . . . . . . . . . . . . 141
TA1886 B . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA603L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D6R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TZ-300L-O . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSWS9P-277 . . . . . . . . . . . . . . . . . . . . . . . 110
PP-20R . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
TA1886 G . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA606 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TA-D7A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TZ-302L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSWS9PD . . . . . . . . . . . . . . . . . . . . . . . . . 110
PP-20R-2P1 . . . . . . . . . . . . . . . . . . . . . . . 141
TA1887 B . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA61 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA-D7B . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
USB-MMP . . . . . . . . . . . . . . . . . . . . . . . . . . 65
OSWS9PDM . . . . . . . . . . . . . . . . . . . . . . . . 110
PP-20R-2P4 . . . . . . . . . . . . . . . . . . . . . . . 141
TA1887 BK . . . . . . . . . . . . . . . . . . . . . . . . 132
TA62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA-D7C . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1101-2M . . . . . . . . . . . . . . . . . . . . . . . . . 147
PP-20R-F2 . . . . . . . . . . . . . . . . . . . . . . . . . 143
TA1887 G . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA620 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D7R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1101FM-M . . . . . . . . . . . . . . . . . . . . . . . 147
PP-20R-P1 . . . . . . . . . . . . . . . . . . . . . . . . 141
TA215LB . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA620B . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D8A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1101-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147
PP-20R-P4 . . . . . . . . . . . . . . . . . . . . . . . . 141
TA236 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA620L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D8R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1104-2M . . . . . . . . . . . . . . . . . . . . . . . . . 147
SMC3D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
TA270A . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
TA620LB . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-L10 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1104FM-M . . . . . . . . . . . . . . . . . . . . . . . 147
SR-500 . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
TA315-1N5 . . . . . . . . . . . . . . . . . . . . . . . . 130
TA631L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-L10-1 . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W220L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1104FM-M 240VAC . . . . . . . . . . . . . . . . . 143
SR-500PS . . . . . . . . . . . . . . . . . . . . . . . . . 149
TA340-10G5 . . . . . . . . . . . . . . . . . . . . . . . 128
TA635 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-L12 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
P1104-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147
SR-ESB . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
TA340-4G5 . . . . . . . . . . . . . . . . . . . . . . . . 128
TA640 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TA-L3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W222 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
W222L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PB-100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
SR-RA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
TA340-4N5 . . . . . . . . . . . . . . . . . . . . . . . . 128
TA656B . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-L4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PB-50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
SS13B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
TA340-6G5 . . . . . . . . . . . . . . . . . . . . . . . . 128
TA666BK . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-L6-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W300L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PB-75 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
SS13F . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
TA340-6N5 . . . . . . . . . . . . . . . . . . . . . . . . 128
TA725 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
TA-L8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W300-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PEW101-M . . . . . . . . . . . . . . . . . . . . . . . . 148
SS20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
TA371LRN5 . . . . . . . . . . . . . . . . . . . . . . . . 135
TA740 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
TA-L9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PEW104-M . . . . . . . . . . . . . . . . . . . . . . . . 148
SS20F . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
TA434-10N5 . . . . . . . . . . . . . . . . . . . . . . . 128
TA744 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
TA-M1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W302L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PF1101FM-M . . . . . . . . . . . . . . . . . . . . . . . 147
TA434-6N5 . . . . . . . . . . . . . . . . . . . . . . . . 128
TA874-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127
TA-MTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
W400A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PF1101-M . . . . . . . . . . . . . . . . . . . . . . . . . 147
SS700Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
SS700ZA . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
TA44 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA874-N5R . . . . . . . . . . . . . . . . . . . . . . . . 127
TA-SFPF . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W400AL . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PF1104FM-M . . . . . . . . . . . . . . . . . . . . . . . 147
SS720A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
TA45 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA875-1G1 . . . . . . . . . . . . . . . . . . . . . . . . 128
TA-SFPFR . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W402A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PF1104-M . . . . . . . . . . . . . . . . . . . . . . . . . 147
SS720AA . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
TA46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA875-G1 . . . . . . . . . . . . . . . . . . . . . . . . . 127
TA-WBBF . . . . . . . . . . . . . . . . . . . . . . . . . . 138
PFEW101-M . . . . . . . . . . . . . . . . . . . . . . . 148
SS721Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
TA47AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TA876-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127
TCA1-MK2 . . . . . . . . . . . . . . . . . . . . . . . . . 152
PFEW104-M . . . . . . . . . . . . . . . . . . . . . . . 148
SS721ZA . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
TA47AR5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TA879 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TCA1RP-MK2 . . . . . . . . . . . . . . . . . . . . . . . 152
PFP1102 . . . . . . . . . . . . . . . . . . . . . . . . . . 143
SSA100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
TA47RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TA880-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127
TCA3-MK2 . . . . . . . . . . . . . . . . . . . . . . . . . 152
PFP1102-M . . . . . . . . . . . . . . . . . . . . . . . . 147
SSA100R-24 . . . . . . . . . . . . . . . . . . . . . . . 102
TA502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA93-2AN5 . . . . . . . . . . . . . . . . . . . . . . . . 135
TCA3RP-MK2 . . . . . . . . . . . . . . . . . . . . . . . 152
PFP1103 . . . . . . . . . . . . . . . . . . . . . . . . . . 143
SSA200 . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
TA502-BX . . . . . . . . . . . . . . . . . . . . . . . . . 138
TA93-2BN5 . . . . . . . . . . . . . . . . . . . . . . . . 135
TCAMA2RND . . . . . . . . . . . . . . . . . . . . . . . 152
PFP1103-M . . . . . . . . . . . . . . . . . . . . . . . . 147
SSA200R-24 . . . . . . . . . . . . . . . . . . . . . . . 102
TA502SW . . . . . . . . . . . . . . . . . . . . . . . . . 138
TA93-2CN5 . . . . . . . . . . . . . . . . . . . . . . . . 135
TCHD1AL2-MK2 . . . . . . . . . . . . . . . . . . . . . 152
TORK 157
TORK 158
NOTES
TERMS OF SALE
TORK VENDOR NUMBER: 662381
1. Prices are F.O.B. our plant.
2. Prices do not include any sales tax.
3. Freight charges will be prepaid on all orders $100.00
and over shipping within continental USA using standard
shipping methods and service.
4. Minimum order – $100.00.
5. Claims for shortage, erroneous charges or price corrections
shall be deemed waived unless made in writing, delivered
to NSi within 30 days of invoice.
6. Terms of payment – 2% 10th prox. net 25th following.
7. Warranties – We strive to produce the highest quality
products on the market today. NSi guarantees all products
to be free of defects in material and workmanship for
a period of 90 days from date of sale. Any claims for
defective material must be agreed to in writing by NSi.
Defective material will be replaced on an F.O.B., our
factory basis. NSi disclaims the implied warranty of fitness
for a particular application.
OTHER PRODUCTS AVAILABLE
ADDRESS
9730 Northcross Center Court
Huntersville, North Carolina
28078 USA
PHONE
office 800.321.5847
technical support 888.500.4598
FAX
800.841.5566
EMAIL
nsi@nsiindustries.com
WEB
www.nsiindustries.com
NSi can provide many other products for special applications
which are not listed in this catalog. If you require an item which
you do not find listed, please contact us. We would be pleased
to provide a quotation upon receipt of a drawing or a sample.
GUARANTEE
It is our goal to provide extraordinary
products and services on a daily basis. If our
products or service do not meet with your
satisfaction, please let us know immediately
and we promise to make every reasonable
effort to remedy the situation.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Page Count : 80 Create Date : 2017:08:23 05:39:18 Creator : PDFium Producer : PDFiumEXIF Metadata provided by EXIF.tools