T r i c a b F l e x i b l e I E C L S Z H
S h i p b o a r d / O f f s h o r e
C a b l e s
L O W S M O K E Z E R O H A L O G E N
i s s u e 1 . 0
Approvals and Certifications
“M110’
– Yacht by Kingship
T R I C A B F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E
8 . 0 . 1
4
CONTENTS
S H I P B O A R D C A B L E S
PRODUCT
SERIES
Flame Retardant
IEC60332-1
AS/NZS1660.5.6
Flame Retardant
IEC60332-3A
AS/NZS1660.5.1
Halogen Free
IEC60754-1&2
AS/NZS1660.5.3
Smoke Emission
IEC61034-1&2
AS/NZS1660.5.2
Fire Resistant
IEC60331
AS/NZS1660.5.5
PAGE NUMBER
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
2
Introduction 4
Low Smoke Zero Halogen (LSZH) - what does it mean? 6
Features and Benefits 8
P O W E R A N D C O N T R O L 1 1 0 º C
Unarmoured BV
PPPPO
12
Unarmoured MK
PPPPO
14
Braided/Armoured DV
PPPPO
16
I N S T R U M E N TA T I O N 1 1 0 º C
Collective screened
Unarmoured RC
PPPPO
18
Braided/Armoured RS
PPPPO
20
Individual and collective screened
Unarmoured EW
PPPPO
22
Braided/Armoured EG
PPPPO
24
P O W E R A N D C O N T R O L F i r e Re s i s t a n t 1 1 0 º C
Unarmoured RR
PPPPP
26
Braided/Armoured BH
PPPPP
28
I N S T R U M E N T A T I O N F i r e R e s i s t a n t 1 1 0 º C
Collective screened
Unarmoured ES
PPPPP
30
Braided/Armoured FJ
PPPPP
32
Individual and collective screened
Unarmoured FC
PPPPP
34
Braided/Armoured FL
PPPPP
36
S H O R E P O W E R 1 1 0 º C
EZ
POOOO
38
S W I T C H B O A R D / PA N E L W I R E 1 1 0 º C
UP
PPPPO
40
TECHNICAL INFORMATION
O F F S H O R E O I L A N D G A S C A B L E S
PRODUCT
SERIES
Flame Retardant
IEC60332-1
AS/NZS1660.5.6
Flame Retardant
IEC60332-3A
AS/NZS1660.5.1
Halogen Free
IEC60754-1&2
AS/NZS1660.5.3
Smoke Emission
IEC61034-1&2
AS/NZS1660.5.2
Fire Resistant
IEC60331
AS/NZS1660.5.5
PAGE NUMBER
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 3
P O W E R A N D C O N T R O L 1 1 0 º C
Braided/Armoured PJ
PPPPO
42
I N S T R U M E N T A T I O N 1 1 0 º C
Collective screened
Braided/Armoured RB
PPPPO
44
Individual and collective screened
Braided/Armoured FZ
PPPPO
46
P O W E R A N D C O N T R O L F i r e Re s i s t a n t 1 1 0 º C
Braided/Armoured HT
PPPPP
48
I N S T R U M E N T A T I O N F i r e R e s i s t a n t 1 1 0 º C
Collective screened
Braided/Armoured FK
PPPPP
50
Individual and collective screened
Braided/Armoured FE
PPPPP
52
S W I T C H B O A R D / PA N E L W I R E 1 1 0 º C
UP
PPPPO
54
55
5
INTRODUCTION
Welcome to Issue 1.0 of our IEC Shipboard/Offshore Cables catalog.
Tricab has been pioneering and re-defining cable technologies for over 30 years.
The cables within this catalogue represent a milestone for the marine industry as they combine the highest
technical performance, outstanding flexibility, reduced weight and user-friendliness.
All cables now include a high strength ripcord under all jackets, and under the insulation 10mmand larger
conductors, for ease of stripping extended lengths.
All Tricab Marine Cables conform to major international standards including IEC and IEEE and carry
approvals from ABS, LR, DNV, BV, GL, NATO, USCG, TC NAVSEA.
Our cables are used globally across a broad range of platforms, including Navy and Defense vessels,
Fast Ferries, Commercial and Work Boats, Tankers, Passenger Liners, and Megayachts.
We operate our own Sales and Distribution networks across Australia, New Zealand, Asia, the Middle East,
Europe, the USA and Canada. This enables us to work directly with our customers in partnership
agreements and deliver the highest possible service levels. Our Manufacturing facility in Worcester, MA,
USA also includes Sales, Engineering, and Warehousing.
We trust that you will find this catalog of value and we look forward to being
of service to you in the near future.
108ft Orca Class inshore patrol vessel by Victoria Shipyard, Victoria BC
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S
LSZH
LSZH simply translates to Low Smoke Zero Halogen and refers to the behaviour of
chemical compounds when combusted - specifically the quantity of smoke generated
and the toxicity of the emissions.
Halogens - What are they?
Halogens are a group of five elements comprising; Fluorine, Chlorine, Bromine, Iodine
and Astatine.
Halogens - and the effect of combustion
In their basic form, Halogens are very toxic, strong oxidizers and very chemically
reactive. In the event of combustion, LSZH and non LSZH cables behave in very
different ways, as indicated below.
Fluorine Chlorine Bromine Iodine Astatine
Tricab LSZH Cables
NO HALOGENS HALOGEN
EMISSIONS
CORROSIVE
ACIDS
LOW SMOKE DENSE SMOKE
NO ACIDS
Non LSZH Cables
LOW SMOKE ZERO HALOGEN (LSZH)
What does it mean?
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
6
What is the difference between LSZH and non LSZH cables?
LSZH cables have a zero Halogen content, emit no toxic fumes, generate very little smoke and produce no corrosive or
caustic acids. LSZH cables are therefore ideally suited for all marine applications where personnel safety and protection
of valuable equipment are of paramount importance.
Non LSZH cables, or Halogenated Cables, are typically manufactured
from thermoplastic compounds, such as PVC. On combustion, these
compounds generate highly toxic fumes that cause severe irritation to
the eyes, nose, mouth, throat and lungs. Increased concentrations are
considered fatal to humans.
They also generate large volumes of dense black smoke that blocks
visibility and severely disrupts evacuation procedures. The smoke and
fumes can also lead to suffocation from smoke inhalation. A one metre
length of burning cable that contains 0.85Kg of PVC will completely
obscure a room of 1000m3with black toxic smoke in less than five
minutes.
When combusted, Halogens combine with moisture to form
Hydrochloric Acid. This extremely corrosive acid is potentially deadly
to humans and always causes extensive property damage. Acids of this
nature aggressively attack electrical switchboards, motors, fixtures,
furnishings, floor coverings, paint surfaces etc. In many cases the
effects of acid corrosion after a fire are much more severe than the
actual fire damage itself.
Tricab LSFLEX®- Insulation & Sheath Materials
Pare halogen free
Pemit low smoke
Pdo not form corrosive acids
Phave an extremely low fuel element
LOW SMOKE ZERO HALOGEN (LSZH)
What does it mean?
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 7
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
AS/NZS1660.5.1
AS/NZS1660.5.2
AS/NZS1660.5.3
AS/NZS1660.5.6
Tricab LSFLEX®- Insulation & Sheath
Materials comply to the following standards:
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
8
FEATURES AND BENEFITS
Fine Copper Stranding - Tricab uses very fine
copper wire for all conductors, in accordance
with ASTM B3-01, ASTM B33-00 and IEC
60228.
Round Concentric Cores - Tricab exclusively
manufactures round cores throughout its entire
size range, and does not use sectorial conduc-
tors.
Lightweight - Tricab has developed specific
product ranges that have reduced weight.
Small OD - Tricab has developed specific prod-
uct ranges that have reduced OD's.
Flexible Construction - Tricab uses a combina-
tion of fine conductors, special compounds and
manufacturing processes to produce a very flexi-
ble cable.
Foot marking - All Tricab cables are foot-
marked as standard, with a descending number
(metre marking also available).
Product marking - Tricab offers personalized
text messages printed onto the cable at regular
intervals, even for short lengths.
F E A T U R E S B E N E F I T S
Provides quick and efficient removal of any length of jacket or insula-
tion without the risk of damage to underlying components. Eliminates
the risk of injury from using razor knives or blades.
Significantly increased flexibility has numerous practical benefits,
including reduced installation time and easier cable handing.
These benefits translate directly into reduced installation time and
cost. Fine stranded conductors also offer improved performance
and reliability when subjected to vibration.
Standard lugs, terminals and connectors can be used,
saving installation time, inventory and cost - also providing better elec-
trical contact with standard round lugs.
Especially relevant to high speed craft, where weight saving
translates into improved performance and overall cost benefits.
Additional cables can be installed within a specified cable tray,
ladder or conduit. A smaller bending radius benefits tight configura-
tions, and smaller glands reduce cost.
Reduced installation time and cost, improved bending radius and
safer cable handling (especially larger sizes).
Assists the installation process and enables accurate stock manage-
ment.
Project Reference Codes, Company Name, Part Numbers, Quality
Data, Marketing Information etc. can all be clearly marked.
Ripcord - Tricab includes a high strength ripcord
under all bedding and overall jackets, and under
the insulation on 10mm2and larger conductors.
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 9
Make to order facility - Tricab can manufacture cables
exactly to customer specifications.
Global distribution - Tricab operates its own network of
company offices and warehouses worldwide. We currently
have operations in the Pacific, Asia, the Middle East,
Europe and North America.
Research & development - Tricab maintains a very active
R&D programme, working very closely with our sales team
and customers. In conjunction with our in-house
laboratory, we are continually improving cable performance.
Quick response - Tricab has invested in manpower,
machinery and materials to provide a short leadtime
manufacturing capability.
Reliable long-term partner - Tricab has been supplying
innovative cable solutions since 1978. We believe in long
term partnerships and have a solid track record of success-
fully completed projects worldwide.
Approvals - Tricab maintains approvals from numerous cer-
tification bodies, including LR, DNV, ABS, BV, GL, UL, CSA.
If required, we also obtain specific case approval.
Quality accreditation - Tricab operates an accredited
Quality system in accordance with ISO 9001:2000, both
within our manufacturing plant and our global offices and
warehouses.
No need for the user to compromise or accept an alterna-
tive cable. Customers receive exactly what they need.
We support customer projects wherever they may be,
streamlining logistics, increasing supply reliability and sav-
ing time and money.
New cable technologies are introduced to our customers
on an ongoing basis.
When cable is needed urgently, either due to an emer-
gency or unexpected contingency, Tricab has the systems
in place to fast-track the manufacturing process, reducing
downtime and saving time and money.
We believe that satisfied customers are our strength and
we do everything in our power to ensure that we both
grow and prosper over the long term.
Reliable certification simplifies the task for procurement
and engineering, saving time and money. It also allows
cables left over from one project to be used for future
projects.
We continually improve our quality performance, which
in turn provides improved products and services to our
customers.
F E A T U R E S B E N E F I T S
SHIPBOARD CABLES
P O W E R A N D C O N T R O L 1 1 0 º C
Unarmoured BV 12
Unarmoured MK 14
Braided/Armoured DV 16
I N S T R U M E N T A T I O N 1 1 0 º C
Collective screened
Unarmoured RC 18
Braided/Armoured RS 20
Individual and collective screened
Unarmoured EW 22
Braided/Armoured EG 24
P O W E R A N D C O N T R O L F i r e Re s i s t a n t 1 1 0 º C
Unarmoured RR 26
Braided/Armoured BH 28
I N S T R U M E N T A T I O N F i r e R e s i s t a n t 1 1 0 º C
Collective screened
Unarmoured ES 30
Braided/Armoured FJ 32
Individual and collective screened
Unarmoured FC 34
Braided/Armoured FL 36
S H O R E P O W E R 1 1 0 º C
EZ 38
S W I T C H B O A R D / PA N E L W I R E 1 1 0 º C
UP 40
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
12
BV
CONSTRUCTION
Conductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV. Includes ripcord on
10mm2 and larger.
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
600/1000 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, BV, GL, USCG, TC
APPLICATION
Flexible Power and Control cables suitable for all shipboard and marine applications.
NUMBER OF CONDUCTOR NOMINAL OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER OD OVER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) INSULATION (mm) RADIUS (kg/km) (Amps)
AREA (mm2) (mm) NOMINAL (mm)
1c 6 3.10 4.7 6.8 27 82 52
1c 10 4.10 5.7 7.8 31 125 72
1c 16 5.10 6.8 9.1 36 184 96
1c 25 6.40 8.5 10.8 43 279 127
1c 35 7.80 9.9 12.4 50 380 157
1c 50 9.20 11.5 14.0 56 528 196
1c 70 10.80 13.3 16.0 64 714 242
1c 95 12.80 15.3 18.3 73 960 293
1c 120 14.50 17.3 20.4 82 1190 339
1c 150 16.30 19.5 22.9 91 1484 389
1c 185 18.00 21.7 25.2 101 1829 444
1c 240 20.30 24.2 28.0 112 2340 522
1c 300 23.00 27.2 31.1 125 2887 601
1c 400 26.00 30.7 34.8 139 3786 670
1c 500 29.20 34.4 38.7 155 4770 720
1c 630 32.80 38.4 43.2 173 5990 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
FLEXIBLE SHIPBOARD POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) (mm) RADIUS (kg/km) (Amps)
AREA (mm2) NOMINAL (mm)
2c 1.5 1.50 8.1 32 75 20
2c 2.5 2.10 9.5 38 108 26
2c 4 2.50 10.4 41 144 34
2c 6 3.10 11.8 47 197 44
2c 10 4.10 13.9 56 304 61
2c 16 5.20 16.4 66 441 82
2c 25 6.40 20.0 80 676 108
2c 35 7.80 22.9 92 916 133
3c 1.5 1.50 8.4 34 91 16
3c 2.5 2.10 10.1 40 135 21
3c 4 2.50 11.0 44 184 28
3c 6 3.10 12.5 50 256 36
3c 10 4.10 14.9 60 407 50
3c 16 5.20 17.6 70 592 67
3c 25 6.40 21.2 85 906 89
3c 35 7.80 24.4 98 1233 110
3c 50 9.20 27.7 111 1720 137
3c 70 10.80 32.0 128 2332 169
3c 95 12.80 36.7 147 3142 205
3c 120 14.50 41.0 164 3897 237
3c 150 16.30 46.2 185 4881 272
3c 185 18.00 51.2 205 6022 311
3c 240 20.30 57.0 228 7701 365
4c 1.5 1.50 9.5 38 116 16
4c 2.5 2.10 11.0 44 167 21
4c 4 2.50 12.2 49 234 28
4c 6 3.10 13.7 55 322 36
4c 10 4.10 16.4 65 516 50
4c 16 5.20 19.3 77 754 67
4c 25 6.40 23.6 94 1165 89
4c 35 7.80 27.1 108 1587 110
4c 50 9.20 31.0 124 2229 137
4c 70 10.80 35.6 142 3012 169
4c 95 12.80 40.8 163 4061 205
4c 120 14.50 45.8 183 5049 237
4c 150 16.30 51.5 206 6319 272
4c 185 18.00 57.0 228 7797 311
5c 1.5 1.50 10.4 42 148 16
5c 2.5 2.10 12.2 49 215 21
5c 4 2.50 13.4 54 295 28
5c 6 3.10 15.3 61 409 36
5c 10 4.10 18.3 73 651 50
5c 16 5.20 21.6 86 948 67
5c 25 6.40 26.3 105 1460 89
5c 35 7.80 30.3 121 1985 110
5c 50 9.20 34.7 139 2784 137
5c 70 10.80 40.0 160 3769 169
5c 95 12.80 45.8 183 5072 205
5c 120 14.50 51.4 206 6300 237
5c 150 16.30 57.8 231 7876 272
5c 185 18.00 64.1 256 9728 311
5c 240 20.30 71.3 285 12438 365
7c 1.5 1.50 11.5 46 175 12
10c 1.5 1.50 14.5 58 248 11
12c 1.5 1.50 15.1 61 289 10
14c 1.5 1.50 15.9 64 330 10
16c 1.5 1.50 17.0 68 378 9
19c 1.5 1.50 17.9 72 439 9
24c 1.5 1.50 21.0 84 555 9
27c 1.5 1.50 21.6 86 615 9
33c 1.5 1.50 23.4 94 746 9
37c 1.5 1.50 24.3 97 827 9
7c 2.5 2.10 13.3 53 254 21
10c 2.5 2.10 17.2 69 366 20
12c 2.5 2.10 17.9 72 428 18
14c 2.5 2.10 18.8 75 492 18
16c 2.5 2.10 20.1 80 561 16
19c 2.5 2.10 21.2 85 655 15
24c 2.5 2.10 24.8 99 827 15
27c 2.5 2.10 25.7 103 927 15
33c 2.5 2.10 27.7 111 1116 15
37c 2.5 2.10 29.0 116 1248 15
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 13
BV
FLEXIBLE SHIPBOARD POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE SHIPBOARD POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
14
MK FLEXIBLE SHIPBOARD POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER OD OVER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) INSULATION (mm) RADIUS (kg/km) (Amps)
AREA (mm2) (mm) NOMINAL (mm)
1c 6 3.10 4.7 6.8 27 82 52
1c 10 4.10 5.7 7.8 31 125 72
1c 16 5.10 6.8 9.1 36 184 96
1c 25 6.40 8.5 10.8 43 279 127
1c 35 7.80 9.9 12.4 50 380 157
1c 50 9.20 11.5 14.0 56 528 196
1c 70 10.80 13.3 16.0 64 714 242
1c 95 12.80 15.3 18.3 73 960 293
1c 120 14.50 17.3 20.4 82 1190 339
1c 150 16.30 19.5 22.9 91 1484 389
1c 185 18.00 21.7 25.2 101 1829 444
1c 240 20.30 24.2 28.0 112 2340 522
1c 300 23.00 27.2 31.1 125 2887 601
1c 400 26.00 30.7 34.8 139 3786 670
1c 500 29.20 34.4 38.7 155 4770 720
1c 630 32.80 38.4 43.2 173 5990 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
CONSTRUCTION
Conductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
600/1000 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, GL, USCG, RAN
APPLICATION
Flexible Power and Control cables suitable for all shipboard and marine applications.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
DEF(AUST) 5000
I S S U E 8 . 0 T R I C A B F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 15
MK
FLEXIBLE SHIPBOARD POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE SHIPBOARD POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) (mm) RADIUS (kg/km) (Amps)
AREA (mm2) NOMINAL (mm)
2c 1.5 1.50 8.1 32 75 20
2c 2.5 2.10 9.5 38 108 26
2c 4 2.50 10.4 41 144 34
2c 6 3.10 11.8 47 197 44
2c 10 4.10 13.9 56 304 61
2c 16 5.20 16.4 66 441 82
2c 25 6.40 20.0 80 676 108
2c 35 7.80 22.9 92 916 133
3c 1.5 1.50 8.4 34 91 16
3c 2.5 2.10 10.1 40 135 21
3c 4 2.50 11.0 44 184 28
3c 6 3.10 12.5 50 256 36
3c 10 4.10 14.9 60 407 50
3c 16 5.20 17.6 70 592 67
3c 25 6.40 21.2 85 906 89
3c 35 7.80 24.4 98 1233 110
3c 50 9.20 27.7 111 1720 137
3c 70 10.80 32.0 128 2332 169
3c 95 12.80 36.7 147 3142 205
3c 120 14.50 41.0 164 3897 237
3c 150 16.30 46.2 185 4881 272
3c 185 18.00 51.2 205 6022 311
3c 240 20.30 57.0 228 7701 365
4c 1.5 1.50 9.5 38 116 16
4c 2.5 2.10 11.0 44 167 21
4c 4 2.50 12.2 49 234 28
4c 6 3.10 13.7 55 322 36
4c 10 4.10 16.4 65 516 50
4c 16 5.20 19.3 77 754 67
4c 25 6.40 23.6 94 1165 89
4c 35 7.80 27.1 108 1587 110
4c 50 9.20 31.0 124 2229 137
4c 70 10.80 35.6 142 3012 169
4c 95 12.80 40.8 163 4061 205
4c 120 14.50 45.8 183 5049 237
4c 150 16.30 51.5 206 6319 272
4c 185 18.00 57.0 228 7797 311
5c 1.5 1.50 10.4 42 148 16
5c 2.5 2.10 12.2 49 215 21
5c 4 2.50 13.4 54 295 28
5c 6 3.10 15.3 61 409 36
5c 10 4.10 18.3 73 651 50
5c 16 5.20 21.6 86 948 67
5c 25 6.40 26.3 105 1460 89
5c 35 7.80 30.3 121 1985 110
5c 50 9.20 34.7 139 2784 137
5c 70 10.80 40.0 160 3769 169
5c 95 12.80 45.8 183 5072 205
5c 120 14.50 51.4 206 6300 237
5c 150 16.30 57.8 231 7876 272
5c 185 18.00 64.1 256 9728 311
5c 240 20.30 71.3 285 12438 365
7c 1.5 1.50 11.5 46 175 12
10c 1.5 1.50 14.5 58 248 11
12c 1.5 1.50 15.1 61 289 10
14c 1.5 1.50 15.9 64 330 10
16c 1.5 1.50 17.0 68 378 9
19c 1.5 1.50 17.9 72 439 9
24c 1.5 1.50 21.0 84 555 9
27c 1.5 1.50 21.6 86 615 9
33c 1.5 1.50 23.4 94 746 9
37c 1.5 1.50 24.3 97 827 9
7c 2.5 2.10 13.3 53 254 21
10c 2.5 2.10 17.2 69 366 20
12c 2.5 2.10 17.9 72 428 18
14c 2.5 2.10 18.8 75 492 18
16c 2.5 2.10 20.1 80 561 16
19c 2.5 2.10 21.2 85 655 15
24c 2.5 2.10 24.8 99 827 15
27c 2.5 2.10 25.7 103 927 15
33c 2.5 2.10 27.7 111 1116 15
37c 2.5 2.10 29.0 116 1248 15
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
16
DV
CONSTRUCTION
Conductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV. Includes ripcord on
10mm2 and larger.
Overall Tape: Polyethylene
Braid/Armour Options:
Tinned Copper Wire Braid (90%)
Galvanized Steel Wire Braid (90%)
(Also available with drain wire under the braid)
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
600/1000 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, BV, GL, USCG, TC, RAN
APPLICATION
Flexible Power and Control cables suitable for all shipboard and marine applications where
mechanical or EMC protection is required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60331
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
FLEXIBLE SHIPBOARD
BRAIDED/ARMOURED POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL NOMINAL OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER OD OVER OD OVER OD OVER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) INSULATION TAPE BRAID (mm) RADIUS (kg/km) (Amps)
AREA (mm2) (mm) (mm) (mm) NOMINAL (mm)
1c 6 3.10 4.7 5.5 6.7 9.0 54 143 52
1c 10 4.10 5.7 6.5 7.7 10.0 60 198 72
1c 16 5.20 6.9 7.7 8.9 11.2 67 264 96
1c 25 6.40 8.5 9.3 10.6 13.1 78 376 127
1c 35 7.80 9.9 10.8 12.0 14.7 88 491 157
1c 50 9.20 11.5 12.3 13.5 16.2 97 653 196
1c 70 10.80 13.3 14.1 15.3 18.3 110 857 242
1c 95 12.80 15.3 16.2 17.4 20.5 123 1122 293
1c 120 14.50 17.3 18.1 19.3 22.7 136 1370 339
1c 150 16.30 19.5 20.4 21.6 24.9 149 1679 389
1c 185 18.00 21.7 22.5 23.7 27.3 164 2043 444
1c 240 20.30 24.2 25.1 26.3 30.0 180 2578 522
1c 300 23.00 27.2 28.0 29.2 33.2 199 3151 601
1c 400 26.00 30.7 31.5 32.7 37.1 222 4093 670
1c 500 29.20 34.4 35.2 36.4 41.0 246 5111 720
1c 630 32.80 38.4 39.3 40.5 45.5 273 6369 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
DEF(AUST) 5000
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 17
DV
FLEXIBLE SHIPBOARD
BRAIDED/ARMOURED POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE SHIPBOARD
BRAIDED/ARMOURED POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km) (Amps)
AREA (mm2) (mm) (mm) NOMINAL (mm)
2c 1.5 1.50 6.8 8.0 10.3 62 155 20
2c 2.5 2.10 8.0 9.3 11.8 71 200 26
2c 4 2.50 8.9 10.1 12.6 76 245 34
2c 6 3.10 10.2 11.4 13.9 83 308 44
2c 10 4.10 12.2 13.4 16.1 97 438 61
2c 16 5.20 14.5 15.7 18.6 112 596 82
2c 25 6.40 17.7 18.9 22.0 132 856 108
2c 35 7.80 20.4 21.6 24.9 150 1119 133
3c 1.5 1.50 7.3 8.5 10.8 65 173 16
3c 2.5 2.10 8.6 9.8 12.3 74 228 21
3c 4 2.50 9.5 10.7 13.2 79 286 28
3c 6 3.10 10.9 12.1 14.8 89 370 36
3c 10 4.10 13.1 14.3 17.2 103 540 50
3c 16 5.20 15.5 16.8 19.9 119 747 67
3c 25 6.40 18.9 20.2 23.5 141 1089 89
3c 35 7.80 21.9 23.1 26.6 160 1439 110
3c 50 9.20 25.0 26.2 30.0 180 1949 137
3c 70 10.80 28.9 30.1 34.3 206 2589 169
3c 95 12.80 33.2 34.4 39.0 234 3427 205
3c 120 14.50 37.3 38.5 43.3 260 4207 237
3c 150 16.30 42.0 43.3 48.5 291 5216 272
3c 185 18.00 46.6 47.8 53.4 320 6380 311
3c 240 20.30 52.0 53.2 59.2 355 8082 365
4c 1.5 1.50 8.0 9.2 11.7 70 203 16
4c 2.5 2.10 9.5 10.7 13.2 79 267 21
4c 4 2.50 10.5 11.7 14.4 87 344 28
4c 6 3.10 12.0 13.2 16.0 96 446 36
4c 10 4.10 14.5 15.7 18.6 112 661 50
4c 16 5.20 17.2 18.5 21.6 130 923 67
4c 25 6.40 21.1 22.3 25.8 155 1367 89
4c 35 7.80 24.4 25.6 29.3 176 1816 110
4c 50 9.20 27.9 29.1 33.1 198 2477 137
4c 70 10.80 32.2 33.5 37.8 227 3302 169
4c 95 12.80 37.0 38.3 43.0 258 4385 205
4c 120 14.50 41.6 42.8 48.0 288 5405 237
4c 150 16.30 46.9 48.2 53.8 323 6709 272
4c 185 18.00 52.0 53.2 59.2 355 8217 311
5c 1.5 1.50 8.9 10.1 12.6 76 236 16
5c 2.5 2.10 10.6 11.8 14.5 87 317 21
5c 4 2.50 11.7 12.9 15.6 94 407 28
5c 6 3.10 13.4 14.6 17.6 105 537 36
5c 10 4.10 16.2 17.4 20.5 123 803 50
5c 16 5.20 19.3 20.5 23.9 143 1127 67
5c 25 6.40 23.6 24.9 28.6 172 1676 89
5c 35 7.80 27.4 28.6 32.5 195 2233 110
5c 50 9.20 31.3 32.6 36.9 221 3067 137
7c 1.5 1.5 9.8 11.0 13.5 81 260 12
10c 1.5 1.5 12.7 13.9 16.6 100 355 11
12c 1.5 1.5 13.3 14.5 17.4 104 406 10
14c 1.5 1.5 14.0 15.2 18.1 109 454 10
16c 1.5 1.5 14.9 16.1 19.0 114 503 9
19c 1.5 1.5 15.8 17.0 20.1 121 577 9
24c 1.5 1.5 18.6 19.9 23.2 139 716 9
27c 1.5 1.5 19.2 20.5 23.8 143 781 9
33c 1.5 1.5 20.9 22.1 25.7 154 925 9
37c 1.5 1.5 21.8 23.0 26.6 159 1014 9
7c 2.5 2.1 11.6 12.9 15.6 93 358 21
10c 2.5 2.1 15.1 16.3 19.2 115 493 20
12c 2.5 2.1 15.8 17.0 20.1 121 566 18
14c 2.5 2.1 16.7 17.9 21.0 126 637 18
16c 2.5 2.1 17.8 19.0 22.1 133 709 16
19c 2.5 2.1 18.9 20.1 23.4 140 818 15
24c 2.5 2.1 22.3 23.5 27.0 162 1018 15
27c 2.5 2.1 23.0 24.2 28.0 168 1124 15
33c 2.5 2.1 25.0 26.2 30.0 180 1328 15
37c 2.5 2.1 26.1 27.3 31.2 187 1470 15
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
18
RC
CONSTRUCTION
Conductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Drain Wire: Tinned annealed copper
Screen: Aluminium/Laminate Tape
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
250 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, GL, USCG, TC
APPLICATION
Flexible Instrumentation cables suitable for all shipboard and marine applications.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-375
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
FLEXIBLE SHIPBOARD INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX.
PAIRS (p) DIAMETER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) (mm) RADIUS (kg/km)
AREA (mm2) NOMINAL (mm)
1p 0.5 0.95 7.4 30 53
2p 0.5 (quad formation) 0.95 8.1 33 68
4p 0.5 0.95 12.2 49 113
8p 0.5 0.95 15.2 61 190
10p 0.5 0.95 16.4 66 225
12p 0.5 0.95 17.9 72 267
16p 0.5 0.95 19.8 79 341
20p 0.5 0.95 20.7 83 405
24p 0.5 0.95 21.7 87 471
27p 0.5 0.95 22.8 91 527
36p 0.5 0.95 26.1 104 688
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 19
RC
FLEXIBLE SHIPBOARD INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX.
PAIRS (p) DIAMETER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) (mm) RADIUS (kg/km)
AREA (mm2) NOMINAL (mm)
1p .75 1.20 7.9 32 63
2p .75 (quad formation) 1.20 8.9 36 86
4p .75 1.20 13.0 52 140
6p .75 1.20 14.8 59 193
8p .75 1.20 16.7 67 244
10p .75 1.20 18.2 73 298
12p .75 1.20 19.9 79 353
14p .75 1.20 20.8 83 400
16p .75 1.20 21.7 87 447
20p .75 1.20 22.9 92 543
24p .75 1.20 24.1 96 634
27p .75 1.20 25.3 101 710
36p .75 1.20 29.0 116 930
1p 1.0 1.30 9.0 36 83
2p 1.0 (quad formation) 1.30 10.0 40 111
4p 1.0 1.30 15.4 61 188
8p 1.0 1.30 19.4 78 328
10p 1.0 1.30 21.2 85 400
12p 1.0 1.30 23.2 93 474
16p 1.0 1.30 25.6 102 609
20p 1.0 1.30 26.8 107 732
24p 1.0 1.30 28.4 113 865
27p 1.0 1.30 29.5 118 959
36p 1.0 1.30 34.1 136 1266
1p 1.5 1.50 9.4 38 97
2p 1.5 (quad formation) 1.50 10.5 42 134
4p 1.5 1.50 16.2 65 231
8p 1.5 1.50 20.8 83 419
10p 1.5 1.50 22.7 91 512
12p 1.5 1.50 24.6 98 600
16p 1.5 1.50 27.1 109 777
20p 1.5 1.50 28.6 115 948
24p 1.5 1.50 30.1 121 1113
27p 1.5 1.50 31.5 126 1247
36p 1.5 1.50 36.4 146 1648
1p 2.5 2.10 10.6 43 131
2p 2.5 (quad formation) 2.10 12.2 49 192
4p 2.5 2.10 19.0 76 334
8p 2.5 2.10 24.5 98 613
10p 2.5 2.10 26.7 107 751
12p 2.5 2.10 29.2 117 893
16p 2.5 2.10 32.2 129 1159
20p 2.5 2.10 34.0 136 1418
24p 2.5 2.10 35.8 143 1670
27p 2.5 2.10 37.5 150 1870
36p 2.5 2.10 43.3 173 2474
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX.
TRIADS (t) DIAMETER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) (mm) RADIUS (kg/km)
AREA (mm2) NOMINAL (mm)
1t .75 1.20 8.3 33 72
3t .75 1.20 12.4 50 148
4t .75 1.20 13.5 54 184
7t .75 1.20 16.3 65 295
1t 1.5 1.50 9.9 39 114
3t 1.5 1.50 15.2 61 246
4t 1.5 1.50 16.6 67 310
7t 1.5 1.50 20.4 81 512
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
20
RS
CONSTRUCTION
Conductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Overall Tape: Polyethylene
Drain Wire: Tinned annealed copper
Screen: Aluminium/Laminate Tape
Overall Tape: Polyethylene
Braid/Armour Options:
Tinned Copper Wire Braid (90%)
Galvanized Steel Wire Braid (90%)
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
250 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, GL, USCG,
APPLICATION
Flexible Instrumentation cables suitable for all shipboard and marine applications, where
mechanical or EMC protection is required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-375
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
FLEXIBLE
SHIPBOARD
COLLECTIVE
SCREENED BRAIDED/ARMOURED
INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) TAPE BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p 0.5 0.95 5.3 6.5 8.8 53 108
2p 0.5 (quad form) 0.95 6.0 7.3 9.6 57 126
4p 0.5 0.95 9.7 10.9 13.4 81 194
8p 0.5 0.95 12.5 13.8 16.5 99 293
10p 0.5 0.95 13.7 14.9 17.8 107 342
12p 0.5 0.95 15.0 16.2 19.1 115 389
16p 0.5 0.95 16.6 17.9 21.0 126 476
20p 0.5 0.95 17.5 18.8 21.9 131 547
24p 0.5 0.95 18.8 20.0 23.4 140 630
27p 0.5 0.95 19.8 21.1 24.4 146 689
36p 0.5 0.95 22.6 23.8 27.3 164 868
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 21
RS
FLEXIBLE
SHIPBOARD
COLLECTIVE
SCREENED BRAIDED/ARMOURED
INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1t .75 1.20 6.2 7.4 9.7 58 129
3t .75 1.20 9.9 11.2 13.7 82 231
4t .75 1.20 11.0 12.3 15.0 90 279
7t .75 1.20 13.6 14.9 17.8 107 411
1t 1.5 1.50 7.6 8.8 11.1 66 176
3t 1.5 1.50 12.5 13.8 16.5 99 346
4t 1.5 1.50 13.9 15.1 18.1 108 426
7t 1.5 1.50 17.2 18.5 21.6 130 648
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) TAPE BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p .75 1.20 5.8 7.0 9.3 56 122
2p .75 (quad form) 1.20 6.7 7.9 10.2 61 147
4p .75 1.20 10.5 11.7 14.4 86 231
8p .75 1.20 14.0 15.2 18.1 109 364
10p .75 1.20 15.3 16.5 19.4 116 422
12p .75 1.20 16.8 18.0 21.1 127 489
14p .75 1.20 17.6 18.9 22.0 132 543
16p .75 1.20 18.6 19.8 23.2 139 604
20p .75 1.20 19.6 20.8 24.2 145 701
24p .75 1.20 21.0 22.2 25.8 155 811
27p .75 1.20 22.2 23.4 27.0 162 890
36p .75 1.20 25.2 26.5 30.2 181 1130
1p 1.0 1.30 6.7 7.9 10.2 61 147
2p 1.0 (quad form) 1.30 7.7 8.9 11.4 69 184
4p 1.0 1.30 12.6 13.9 16.6 99 292
8p 1.0 1.30 16.5 17.8 20.9 125 468
10p 1.0 1.30 18.1 19.3 22.6 136 552
12p 1.0 1.30 19.8 21.1 24.4 146 633
16p 1.0 1.30 22.0 23.3 26.8 161 786
20p 1.0 1.30 23.2 24.5 28.2 169 926
24p 1.0 1.30 24.9 26.1 29.9 179 1065
27p 1.0 1.30 26.3 27.5 31.5 189 1181
36p 1.0 1.30 29.9 31.2 35.3 212 1503
1p 1.5 1.50 7.1 8.3 10.6 64 164
2p 1.5 (quad form) 1.50 8.2 9.4 11.9 72 211
4p 1.5 1.50 13.5 14.7 17.6 106 347
8p 1.5 1.50 17.7 18.9 22.0 132 562
10p 1.5 1.50 19.3 20.6 23.9 143 668
12p 1.5 1.50 21.2 22.5 26.0 156 778
16p 1.5 1.50 23.6 24.8 28.6 171 974
20p 1.5 1.50 24.9 26.1 29.9 179 1147
24p 1.5 1.50 26.7 27.9 31.9 191 1336
27p 1.5 1.50 28.2 29.4 33.6 201 1484
36p 1.5 1.50 32.1 33.3 37.7 226 1902
1p 2.5 2.10 8.3 9.6 12.1 72 212
2p 2.5 (quad form) 2.10 9.7 10.9 13.4 80 277
4p 2.5 2.10 16.1 17.3 20.4 123 471
8p 2.5 2.10 21.2 22.4 25.9 156 790
10p 2.5 2.10 23.2 24.4 28.1 169 945
12p 2.5 2.10 25.4 26.7 30.4 182 1096
16p 2.5 2.10 28.3 29.5 33.7 202 1394
20p 2.5 2.10 29.8 31.1 35.2 211 1655
24p 2.5 2.10 32.0 33.2 37.6 226 1937
27p 2.5 2.10 33.8 35.0 39.6 238 2154
36p 2.5 2.10 38.5 39.7 44.7 268 2790
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
22
EW
CONSTRUCTION
Conductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Overall Tape: Polyethylene
Drain Wire: Tinned annealed copper
Screen: Individual and Collective
Aluminium/Laminate Tape
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
250 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, GL, USCG, TC
APPLICATION
Flexible Instrumentation cables suitable for all shipboard and marine applications.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-375
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
FLEXIBLE SHIPBOARD INDIVIDUAL
& COLLECTIVE SCREENED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX.
PAIRS (p) DIAMETER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) (mm) RADIUS (kg/km)
AREA (mm2) NOMINAL (mm)
1p 0.5 0.95 7.4 30 52
2p 0.5 0.95 11.6 46 104
4p 0.5 0.95 13.5 54 148
8p 0.5 0.95 17.2 69 262
10p 0.5 0.95 18.5 74 313
12p 0.5 0.95 20.2 81 371
16p 0.5 0.95 22.1 89 471
20p 0.5 0.95 23.4 93 572
24p 0.5 0.95 24.8 99 670
27p 0.5 0.95 26.2 105 751
36p 0.5 0.95 29.5 118 980
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 23
EW
FLEXIBLE SHIPBOARD INDIVIDUAL
& COLLECTIVE SCREENED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE SHIPBOARD INDIVIDUAL
& COLLECTIVE SCREENED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX.
PAIRS (p) DIAMETER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) (mm) RADIUS (kg/km)
AREA (mm2) NOMINAL (mm)
1p .75 1.20 7.9 32 62
2p .75 1.20 12.4 50 122
4p .75 1.20 14.8 59 182
8p .75 1.20 18.6 75 320
10p .75 1.20 20.3 81 390
12p .75 1.20 22.0 88 457
16p .75 1.20 24.3 97 590
20p .75 1.20 25.6 103 718
24p .75 1.20 27.2 109 842
27p .75 1.20 28.8 115 945
36p .75 1.20 32.4 130 1235
1p 1.0 1.30 9.0 36 82
2p 1.0 1.30 13.9 56 157
4p 1.0 1.30 16.6 67 237
8p 1.0 1.30 21.4 86 429
10p 1.0 1.30 23.3 93 524
12p 1.0 1.30 25.5 102 622
16p 1.0 1.30 28.2 113 803
20p 1.0 1.30 29.5 118 970
24p 1.0 1.30 31.5 126 1149
27p 1.0 1.30 33.1 132 1279
36p 1.0 1.30 37.5 150 1684
1p 1.5 1.50 9.4 38 95
2p 1.5 1.50 14.8 59 186
4p 1.5 1.50 17.4 70 285
8p 1.5 1.50 22.8 91 522
10p 1.5 1.50 24.6 98 632
12p 1.5 1.50 26.9 107 751
16p 1.5 1.50 29.7 119 975
20p 1.5 1.50 31.3 125 1192
24p 1.5 1.50 33.5 134 1414
27p 1.5 1.50 35.2 141 1575
36p 1.5 1.50 39.9 159 2077
1p 2.5 2.10 10.6 43 128
2p 2.5 2.10 17.1 68 256
4p 2.5 2.10 20.5 82 401
8p 2.5 2.10 26.5 106 739
10p 2.5 2.10 28.9 115 907
12p 2.5 2.10 31.5 126 1078
16p 2.5 2.10 34.8 139 1402
20p 2.5 2.10 36.7 147 1717
24p 2.5 2.10 39.2 157 2039
27p 2.5 2.10 41.2 165 2274
36p 2.5 2.10 46.7 187 3001
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX.
TRIADS (t) DIAMETER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) (mm) RADIUS (kg/km)
AREA (mm2) NOMINAL (mm)
1t 0.75 1.2 8.3 33 70
3t 0.75 1.2 13.6 54 177
4t 0.75 1.2 15.0 60 226
7t 0.75 1.2 18.1 72 363
1t 1.5 1.5 9.9 39 110
3t 1.5 1.5 16.4 65 286
4t 1.5 1.5 18.1 73 368
7t 1.5 1.5 21.9 88 601
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
24
EG
CONSTRUCTION
Conductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Overall Tape: Polyethylene
Drain Wire: Tinned annealed copper
Screen: Individual and Collective
Aluminium/Laminate Tape
Overall Tape: Polyethylene
Braid/Armour Options:
Tinned Copper Wire Braid (90%)
Galvanized Steel Wire Braid (90%
Ripcord: High strength ripcord under
sheath.)
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
250 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, GL, USCG,
APPLICATION
Flexible Instrumentation cables suitable for all shipboard and marine applications, where
mechanical or EMC protection is required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-375
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
FLEXIBLE SHIPBOARD INDIVIDUAL
& COLLECTIVE SCREENED BRAIDED/
ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p 0.5 0.95 4.2 6.8 9.1 55 113
2p 0.5 0.95 8.1 10.6 13.1 79 212
4p 0.5 0.95 10.1 12.5 15.2 91 246
8p 0.5 0.95 13.7 15.8 18.7 112 381
10p 0.5 0.95 15.0 17.1 20.3 122 448
12p 0.5 0.95 16.5 18.6 21.8 131 512
16p 0.5 0.95 18.4 20.6 23.9 143 632
20p 0.5 0.95 19.4 21.6 24.9 149 734
24p 0.5 0.95 20.9 23.0 26.5 159 849
27p 0.5 0.95 22.1 24.2 27.7 166 932
36p 0.5 0.95 25.2 27.3 31.3 188 1193
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 25
EG
FLEXIBLE SHIPBOARD INDIVIDUAL
& COLLECTIVE SCREENED BRAIDED/
ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE SHIPBOARD INDIVIDUAL
& COLLECTIVE SCREENED BRAIDED/
ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1t 0.75 1.20 5.0 7.7 10.0 60 133
3t 0.75 1.20 10.5 12.6 15.3 92 275
4t 0.75 1.20 11.7 13.8 16.6 99 329
7t 0.75 1.20 14.6 16.7 19.9 119 493
1t 1.5 1.50 6.4 9.1 11.6 70 181
3t 1.5 1.50 13.1 15.2 18.1 109 404
4t 1.5 1.50 14.6 16.7 19.9 119 498
7t 1.5 1.50 18.2 20.3 23.7 142 757
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p .75 1.20 4.7 7.3 9.6 58 127
2p .75 1.20 8.9 11.5 14.0 84 248
4p .75 1.20 11.1 13.6 16.3 98 285
8p .75 1.20 15.1 17.3 20.4 122 456
10p .75 1.20 16.6 18.7 21.9 131 533
12p .75 1.20 18.2 20.4 23.7 142 618
16p .75 1.20 20.4 22.5 26.0 156 768
20p .75 1.20 21.5 23.6 27.2 163 897
24p .75 1.20 23.1 25.2 29.0 174 1041
27p .75 1.20 24.4 26.5 30.3 182 1146
36p .75 1.20 27.8 30.0 34.1 205 1463
1p 1.0 1.30 5.6 8.2 10.5 63 153
2p 1.0 1.30 10.4 13.0 15.7 94 320
4p 1.0 1.30 13.0 15.5 18.4 110 360
8p 1.0 1.30 17.7 19.8 23.1 139 586
10p 1.0 1.30 19.4 21.5 24.9 149 689
12p 1.0 1.30 21.3 23.5 27.0 162 801
16p 1.0 1.30 23.8 25.9 29.7 178 1002
20p 1.0 1.30 25.1 27.2 31.2 187 1187
24p 1.0 1.30 27.0 29.1 33.0 198 1372
27p 1.0 1.30 28.5 30.7 34.8 209 1523
36p 1.0 1.30 32.5 34.7 39.2 235 1961
1p 1.5 1.50 6.0 8.6 10.9 66 170
2p 1.5 1.50 11.1 13.6 16.4 98 362
4p 1.5 1.50 13.9 16.3 19.2 115 411
8p 1.5 1.50 18.8 21.0 24.3 146 683
10p 1.5 1.50 20.7 22.8 26.4 158 815
12p 1.5 1.50 22.7 24.9 28.6 172 951
16p 1.5 1.50 25.4 27.5 31.5 189 1196
20p 1.5 1.50 26.8 28.9 32.8 197 1414
24p 1.5 1.50 28.7 30.9 35.0 210 1652
27p 1.5 1.50 30.4 32.5 36.9 221 1836
36p 1.5 1.50 34.7 36.8 41.4 248 2361
1p 2.5 2.10 7.2 9.9 12.4 74 218
2p 2.5 2.10 13.2 15.7 18.6 112 483
4p 2.5 2.10 16.4 18.9 22.0 132 546
8p 2.5 2.10 22.3 24.5 28.2 169 936
10p 2.5 2.10 24.5 26.6 30.4 182 1113
12p 2.5 2.10 26.9 29.1 33.0 198 1304
16p 2.5 2.10 30.1 32.2 36.6 219 1663
20p 2.5 2.10 31.7 33.9 38.2 229 1981
24p 2.5 2.10 34.1 36.2 40.8 245 2322
27p 2.5 2.10 36.0 38.2 42.9 258 2584
36p 2.5 2.10 41.1 43.2 48.4 291 3353
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
26
RR
CONSTRUCTION
Conductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Flame Barrier: Fire Resistant, Halogen Free,
Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV. Includes ripcord on
10mm2 and larger.
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
600/1000 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, GL, USCG, TC
APPLICATION
Flexible Power and Control cables suitable for all shipboard and marine applications, where
circuit integrity is required under fire conditions
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60331-11
IEC 60331-21
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
FLEXIBLE SHIPBOARD
FIRE RESISTANT POWER AND CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER OD OVER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) INSULATION (mm) RADIUS (kg/km) (Amps)
AREA (mm2) (mm) NOMINAL (mm)
1c 6 3.10 5.4 7.5 60 92 52
1c 10 4.10 6.4 8.7 70 141 72
1c 16 5.10 7.6 9.9 79 198 96
1c 25 6.40 9.1 11.6 93 294 127
1c 35 7.80 10.6 13.1 105 393 157
1c 50 9.20 12.2 14.9 119 548 196
1c 70 10.80 14.0 17.0 136 741 242
1c 95 12.80 16.2 19.1 153 988 293
1c 120 14.50 18.1 21.2 170 1224 339
1c 150 16.30 20.3 23.6 189 1519 389
1c 185 18.00 22.4 26.0 208 1867 444
1c 240 20.30 25.0 28.7 230 2383 522
1c 300 23.00 27.9 31.9 255 2934 601
1c 400 26.00 31.4 35.6 284 3839 670
1c 500 29.20 35.1 39.7 317 4839 720
1c 630 32.80 39.2 43.9 352 6055 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 27
RR
FLEXIBLE SHIPBOARD
FIRE RESISTANT POWER AND CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE SHIPBOARD
FIRE RESISTANT POWER AND CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) (mm) RADIUS (kg/km) (Amps)
AREA (mm2) NOMINAL (mm)
2c 1.5 1.50 9.7 77 98 20
2c 2.5 2.10 11.0 88 132 26
2c 4 2.50 12.0 96 175 34
2c 6 3.10 13.3 106 229 44
2c 10 4.10 15.6 125 346 61
2c 16 5.10 18.1 144 488 82
2c 25 6.40 21.2 170 716 108
2c 35 7.80 24.2 194 963 133
3c 1.5 1.50 9.9 79 116 16
3c 2.5 2.10 11.8 95 167 21
3c 4 2.50 12.8 102 221 28
3c 6 3.10 14.3 115 298 36
3c 10 4.10 16.6 133 451 50
3c 16 5.10 19.2 154 643 67
3c 25 6.40 22.8 182 960 89
3c 35 7.80 26.0 208 1295 110
3c 50 9.20 29.5 236 1793 137
3c 70 10.80 33.8 270 2432 169
3c 95 12.80 38.5 308 3257 205
3c 120 14.50 43.0 344 4044 237
3c 150 16.30 48.0 384 5030 272
3c 185 18.00 52.9 423 6187 311
3c 240 20.30 58.7 470 7884 365
4c 1.5 1.50 11.1 89 147 16
4c 2.5 2.10 12.9 103 205 21
4c 4 2.5 14.0 112 275 28
4c 6 3.10 15.7 125 372 36
4c 10 4.10 18.4 147 575 50
4c 16 5.10 21.3 170 822 67
4c 25 6.40 25.3 202 1229 89
4c 35 7.80 28.9 231 1661 110
4c 50 9.20 32.8 262 2308 137
4c 70 10.80 37.5 300 3133 169
4c 95 12.80 43.0 344 4213 205
4c 120 14.50 48.0 384 5229 237
4c 150 16.30 53.4 428 6503 272
4c 185 18.00 58.9 471 7999 311
5c 1.5 1.50 12.4 99 180 16
5c 2.5 2.10 14.4 115 251 21
5c 4 2.50 15.6 125 337 28
5c 6 3.10 17.5 140 457 36
5c 10 4.10 20.5 164 708 50
5c 16 5.10 23.8 190 1012 67
5c 25 6.40 28.2 226 1515 89
5c 35 7.80 32.3 258 2049 110
5c 50 9.20 36.8 295 2860 137
7c 1.5 1.50 13.5 108 218 12
10c 1.5 1.50 17.5 140 314 11
12c 1.5 1.50 18.2 145 366 10
14c 1.5 1.50 19.1 153 419 10
16c 1.5 1.50 20.4 163 478 9
19c 1.5 1.50 21.5 172 556 9
24c 1.5 1.50 25.4 203 709 9
27c 1.5 1.50 26.2 209 786 9
33c 1.5 1.50 28.4 227 951 9
37c 1.5 1.50 29.5 236 1054 9
7c 2.5 2.10 15.7 126 305 21
10c 2.5 2.10 20.3 162 440 20
12c 2.5 2.10 21.1 169 514 18
14c 2.5 2.10 22.2 178 589 18
16c 2.5 2.10 23.7 190 673 16
19c 2.5 2.10 25.3 202 792 15
24c 2.5 2.10 29.6 237 998 15
27c 2.5 2.10 30.5 244 1109 15
33c 2.5 2.10 33.0 264 1342 15
37c 2.5 2.10 34.6 276 1501 15
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
28
BH
CONSTRUCTION
Conductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Flame Barrier: Fire Resistant, Halogen Free,
Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV. Includes ripcord on
10mm2 and larger.
Overall Tape: Polyethylene
Braid/Armour Options:
Tinned Copper Wire Braid (90%)
Galvanized Steel Wire Braid (90%)
(Also available with drain wire under the braid)
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
600/1000 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, GL, USCG, TC
APPLICATION
Flexible Power and Control cables suitable for all shipboard and marine applications, where circuit
integrity is required under fire conditions and mechanical or EMC protection is also required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60331-11
IEC 60331-21
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
FLEXIBLE SHIPBOARD FIRE RESISTANT
BRAIDED/ARMOURED POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL NOMINAL OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER OD OVER OD OVER OD OVER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) INSULATION BEDDING BRAID (mm) RADIUS (kg/km) (Amps)
AREA (mm2) (mm) (mm) (mm) NOMINAL (mm)
1c 6 6.5 5.4 6.2 7.4 9.7 97 160 52
1c 10 4.1 6.4 7.3 8.5 10.8 108 217 72
1c 16 5.1 7.6 8.4 9.6 12.1 121 287 96
1c 25 6.4 9.1 10.0 11.2 13.7 137 394 127
1c 35 7.8 10.6 11.4 12.7 15.4 154 511 157
1c 50 9.2 12.2 13.0 14.2 17.2 172 680 196
1c 70 10.8 14.0 14.9 16.1 19.0 190 886 242
1c 95 12.8 16.2 17.0 18.2 21.3 213 1158 293
1c 120 14.5 18.1 18.9 20.2 23.5 235 1412 339
1c 150 16.3 20.3 21.1 22.3 25.8 258 1728 389
1c 185 18.0 22.4 23.2 24.5 28.2 282 2096 444
1c 240 20.3 25.0 25.8 27.0 31.0 310 2636 522
1c 300 23.0 27.9 28.8 30.0 34.1 341 3215 601
1c 400 26.0 31.4 32.2 33.4 37.8 378 4152 670
1c 500 29.2 35.1 35.9 37.1 41.9 419 5188 720
1c 630 32.8 39.2 40.0 41.2 46.2 462 6441 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 29
BH
FLEXIBLE SHIPBOARD FIRE RESISTANT
BRAIDED/ARMOURED POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) TAPE BRAID (mm) RADIUS (kg/km) (Amps)
AREA (mm2) (mm) (mm) NOMINAL (mm)
2c 1.5 1.50 8.2 9.4 11.9 119 193 20
2c 2.5 2.10 9.5 10.7 13.2 132 239 26
2c 4 2.50 10.4 11.6 14.3 143 291 34
2c 6 3.10 11.6 12.8 15.6 156 357 44
2c 10 4.10 13.7 14.9 17.8 178 494 61
2c 16 5.10 16.0 17.2 20.3 203 658 82
2c 25 6.40 18.9 20.1 23.5 235 913 108
2c 35 7.80 21.7 22.9 26.5 265 1185 133
3c 1.5 1.50 8.7 10.0 12.5 125 215 16
3c 2.5 2.10 10.2 11.4 13.9 139 270 21
3c 4 2.50 11.1 12.3 15.0 150 337 28
3c 6 3.10 12.4 13.7 16.4 164 421 36
3c 10 4.10 14.7 15.9 18.8 188 598 50
3c 16 5.10 17.1 18.3 21.4 214 810 67
3c 25 6.40 20.3 21.5 24.8 248 1146 89
3c 35 7.80 23.3 24.5 28.3 283 1512 110
3c 50 9.20 26.6 27.8 31.7 317 2034 137
3c 70 10.80 30.4 31.7 35.8 358 2689 169
3c 95 12.80 35.0 36.2 40.8 408 3552 205
3c 120 14.50 39.1 40.3 45.3 453 4364 237
3c 150 16.30 43.6 44.8 50.2 502 5374 272
3c 185 18.00 48.1 49.3 54.9 549 6537 311
3c 240 20.30 53.5 54.7 60.7 607 8254 365
4c 1.5 1.50 9.6 10.9 13.4 134 249 16
4c 2.5 2.10 11.2 12.5 15.2 152 321 21
4c 4 2.50 12.3 13.5 16.2 162 400 28
4c 6 3.10 13.8 15.0 17.9 179 511 36
4c 10 4.10 16.3 17.5 20.6 206 737 50
4c 16 5.10 19.0 20.2 23.6 236 1007 67
4c 25 6.40 22.6 23.8 27.3 273 1436 89
4c 35 7.80 26.0 27.2 31.1 311 1903 110
4c 50 9.20 29.6 30.8 35.0 350 2578 137
4c 70 10.80 34.0 35.2 39.8 398 3436 169
4c 95 12.80 39.0 40.2 45.2 452 4552 205
4c 120 14.50 43.6 44.8 50.2 502 5598 237
4c 150 16.30 48.7 49.9 55.7 557 6903 272
4c 185 18.00 53.7 55.0 61.2 612 8429 311
5c 1.5 1.50 10.8 12.0 14.7 147 294 16
5c 2.5 2.10 12.5 13.8 16.5 165 378 21
5c 4 2.50 13.7 14.9 17.8 178 480 28
5c 6 3.10 15.4 16.6 19.8 198 616 36
5c 10 4.10 18.2 19.4 22.8 228 894 50
5c 16 5.10 21.3 22.5 26.0 260 1228 67
5c 25 6.40 25.3 26.5 30.3 303 1761 89
5c 35 7.80 29.2 30.4 34.5 345 2340 110
5c 50 9.20 33.3 34.5 39.1 391 3191 137
7c 1.5 1.5 11.9 13.1 15.8 158 323 12
12c 1.5 1.5 16.1 17.3 20.4 204 507 10
19c 1.5 1.5 19.2 20.4 23.8 238 722 9
24c 1.5 1.5 22.7 23.9 27.5 275 897 9
27c 1.5 1.5 23.5 24.7 28.4 284 987 9
33c 1.5 1.5 25.5 26.7 30.4 304 1160 9
37c 1.5 1.5 26.6 27.8 31.7 317 1281 9
7c 2.5 2.1 13.8 15.1 18.0 180 428 21
12c 2.5 2.1 18.8 20.1 23.4 234 678 18
19c 2.5 2.1 22.5 23.8 27.3 273 978 15
24c 2.5 2.1 26.7 27.9 31.8 318 1226 15
27c 2.5 2.1 27.5 28.8 32.7 327 1344 15
33c 2.5 2.1 29.9 31.1 35.3 353 1597 15
37c 2.5 2.1 31.2 32.4 36.8 368 1766 15
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
30
ES
CONSTRUCTION
Conductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Flame Barrier: Fire Resistant, Halogen Free,
Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Overall Tape: Polyethylene
Drain Wire: Tinned annealed copper
Screen: Aluminium/Laminate Tape
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
250 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, GL, USCG, TC
APPLICATION
Flexible Instrumentation cables suitable for all shipboard and marine applications, where circuit
integrity is required under fire conditions.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-375
IEC 60331-11
IEC 60331-21
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
FLEXIBLE SHIPBOARD FIRE RESISTANT
COLLECTIVE SCREENED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX.
PAIRS (p) DIAMETER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) (mm) RADIUS (kg/km)
AREA (mm2) NOMINAL (mm)
1p 0.5 0.95 8.3 66 67
2p 0.5 (quad formation) 0.95 9.4 75 90
4p 0.5 0.95 14.3 115 151
8p 0.5 0.95 18.1 145 259
10p 0.5 0.95 19.5 156 309
12p 0.5 0.95 21.3 170 366
16p 0.5 0.95 23.5 188 469
20p 0.5 0.95 24.6 197 561
24p 0.5 0.95 26.3 211 663
27p 0.5 0.95 27.6 221 735
36p 0.5 0.95 31.3 251 966
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 31
ES
FLEXIBLE SHIPBOARD FIRE RESISTANT
COLLECTIVE SCREENED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE SHIPBOARD FIRE RESISTANT
COLLECTIVE SCREENED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX.
PAIRS (p) DIAMETER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) (mm) RADIUS (kg/km)
AREA (mm2) NOMINAL (mm)
1p .75 1.20 9.4 76 85
2p .75 (quad formation) 1.20 10.5 84 113
4p .75 1.20 16.0 128 190
6p .75 1.20 18.3 146 263
8p .75 1.20 20.9 167 340
10p .75 1.20 22.8 182 414
12p .75 1.20 24.7 197 483
14p .75 1.20 26.0 208 556
16p .75 1.20 27.2 218 622
20p .75 1.20 28.7 230 754
24p .75 1.20 30.8 246 892
27p .75 1.20 32.3 258 989
36p .75 1.20 36.6 293 1301
1p 1.0 1.30 10.5 84 106
2p 1.0 (quad formation) 1.30 12.0 96 146
4p 1.0 1.30 18.6 149 244
8p 1.0 1.30 24.0 192 436
10p 1.0 1.30 26.2 210 530
12p 1.0 1.30 28.6 229 628
16p 1.0 1.30 31.6 253 807
20p 1.0 1.30 33.1 265 969
24p 1.0 1.30 35.5 284 1145
27p 1.0 1.30 37.4 299 1282
36p 1.0 1.30 42.4 339 1683
1p 1.5 1.50 10.8 86 120
2p 1.5 (quad formation) 1.50 12.4 99 170
4p 1.5 1.50 19.3 154 291
8p 1.5 1.50 24.9 199 528
10p 1.5 1.50 27.1 217 645
12p 1.5 1.50 29.7 237 766
16p 1.5 1.50 32.8 262 989
20p 1.5 1.50 34.6 277 1206
24p 1.5 1.50 37.0 296 1428
27p 1.5 1.50 39.0 312 1600
36p 1.5 1.50 44.0 352 2090
1p 2.5 2.10 12.3 98 161
2p 2.5 (quad formation) 2.10 13.9 112 228
4p 2.5 2.10 22.5 180 407
8p 2.5 2.10 29.1 233 742
10p 2.5 2.10 31.7 254 908
12p 2.5 2.10 34.6 277 1078
16p 2.5 2.10 38.3 306 1396
20p 2.5 2.10 40.4 323 1704
24p 2.5 2.10 43.2 345 2020
27p 2.5 2.10 45.6 364 2263
36p 2.5 2.10 51.6 413 2979
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX.
TRIADS (t) DIAMETER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) (mm) RADIUS (kg/km)
AREA (mm2) NOMINAL (mm)
1t .75 1.20 9.9 79 98
3t .75 1.20 15.3 122 201
4t .75 1.20 16.7 134 251
7t .75 1.20 20.4 164 410
1t 1.5 1.50 11.5 92 144
3t 1.5 1.50 18.2 145 310
4t 1.5 1.50 20.1 161 398
7t 1.5 1.50 24.4 195 648
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
32
FJ
CONSTRUCTION
Conductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Flame Barrier: Fire Resistant, Halogen Free,
Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Overall Tape: Polyethylene
Drain Wire: Tinned annealed copper
Screen: Aluminium/Laminate Tape
Overall Tape: Polyethylene
Braid/Armour Options:
Tinned Copper Wire Braid (90%)
Galvanized Steel Wire Braid (90%)
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
250 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, BV, GL, USCG, TC
APPLICATION
Flexible Instrumentation cables suitable for all shipboard and marine applications, where circuit
integrity is required under fire conditions and mechanical or EMC protection is also required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-375
IEC 60331-11
IEC 60331-21
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
FLEXIBLE SHIPBOARD
FIRE RESISTANT COLLECTIVE SCREENED
BRAIDED/ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p 0.5 0.95 6.2 7.4 9.7 97 130
2p 0.5 (quad form) 0.95 7.1 8.4 10.7 107 155
4p 0.5 0.95 11.6 12.9 15.6 156 247
8p 0.5 0.95 15.1 16.4 19.3 193 382
10p 0.5 0.95 16.6 17.8 20.9 209 449
12p 0.5 0.95 18.2 19.4 22.7 227 519
16p 0.5 0.95 20.2 21.4 24.7 247 631
20p 0.5 0.95 21.3 22.5 26.0 260 739
24p 0.5 0.95 22.8 24.0 27.6 276 845
27p 0.5 0.95 24.1 25.3 29.0 290 936
36p 0.5 0.95 27.4 28.6 32.6 326 1184
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 33
FJ
FLEXIBLE SHIPBOARD
FIRE RESISTANT COLLECTIVE SCREENED
BRAIDED/ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE SHIPBOARD
FIRE RESISTANT COLLECTIVE SCREENED
BRAIDED/ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1t .75 1.20 7.6 8.8 11.1 111 162
3t .75 1.20 12.6 13.8 16.5 165 304
4t .75 1.20 14.0 15.2 18.1 181 370
7t .75 1.20 17.3 18.6 21.7 217 549
1t 1.5 1.50 9.0 10.3 12.8 128 217
3t 1.5 1.50 15.3 16.5 19.4 194 431
4t 1.5 1.50 17.0 18.2 21.3 213 531
7t 1.5 1.50 21.0 22.3 25.8 258 818
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p .75 1.20 7.1 8.4 10.7 107 153
2p .75 (quad form) 1.20 8.2 9.5 12.0 120 190
4p .75 1.20 13.3 14.5 17.4 174 303
8p .75 1.20 17.8 19.0 22.1 221 484
10p .75 1.20 19.4 20.7 24.0 240 571
12p .75 1.20 21.3 22.6 26.1 261 662
16p .75 1.20 23.7 24.9 28.7 287 819
20p .75 1.20 25.0 26.2 30.0 300 954
24p .75 1.20 26.8 28.0 32.0 320 1105
27p .75 1.20 28.3 29.5 33.7 337 1224
36p .75 1.20 32.2 33.5 37.8 378 1555
1p 1.0 1.30 8.2 9.4 11.9 119 186
2p 1.0 (quad form) 1.30 9.5 10.7 13.2 132 230
4p 1.0 1.30 15.7 17.0 20.1 201 378
8p 1.0 1.30 20.7 21.9 25.5 255 609
10p 1.0 1.30 22.7 23.9 27.4 274 712
12p 1.0 1.30 24.9 26.1 29.8 298 827
16p 1.0 1.30 27.7 28.9 32.8 328 1027
20p 1.0 1.30 29.2 30.4 34.6 346 1210
24p 1.0 1.30 31.3 32.5 36.9 369 1404
27p 1.0 1.30 33.1 34.3 38.6 386 1544
36p 1.0 1.30 37.6 38.9 43.6 436 1980
1p 1.5 1.50 8.5 9.7 12.2 122 203
2p 1.5 (quad form) 1.50 9.9 11.1 13.6 136 257
4p 1.5 1.50 16.4 17.6 20.7 207 430
8p 1.5 1.50 21.6 22.8 26.3 263 709
10p 1.5 1.50 23.6 24.8 28.6 286 842
12p 1.5 1.50 25.9 27.2 31.1 311 981
16p 1.5 1.50 28.8 30.1 34.2 342 1228
20p 1.5 1.50 30.4 31.6 35.8 358 1447
24p 1.5 1.50 32.6 33.9 38.2 382 1686
27p 1.5 1.50 34.5 35.7 40.3 403 1873
36p 1.5 1.50 39.3 40.5 45.5 455 2413
1p 2.5 2.10 9.8 11.0 13.5 135 252
2p 2.5 (quad form) 2.10 11.4 12.7 15.4 154 333
4p 2.5 2.10 19.2 20.4 23.7 237 562
8p 2.5 2.10 25.4 26.6 30.3 303 945
10p 2.5 2.10 27.8 29.0 32.9 329 1129
12p 2.5 2.10 30.5 31.7 35.9 359 1320
16p 2.5 2.10 33.9 35.1 39.7 397 1676
20p 2.5 2.10 35.8 37.0 41.8 418 1999
24p 2.5 2.10 38.4 39.6 44.6 446 2336
27p 2.5 2.10 40.6 41.8 46.8 468 2583
36p 2.5 2.10 46.2 47.4 53.0 530 3357
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
34
FC
CONSTRUCTION
Conductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Flame Barrier: Fire Resistant, Halogen Free,
Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Overall Tape: Polyethylene
Drain Wire: Tinned annealed copper
Screen: Individual and Collective
Aluminium/Laminate Tape
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
250 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, GL, USCG,
APPLICATION
Flexible Instrumentation cables suitable for all shipboard and marine applications, where
circuit integrity is required under fire conditions.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-375
IEC 60331-11
IEC 60331-21
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
FLEXIBLE
SHIPBOARD
FIRE RESISTANT
INDIVIDUAL & COLLECTIVE SCREENED
INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX.
PAIRS (p) DIAMETER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) (mm) RADIUS (kg/km)
AREA (mm2) NOMINAL (mm)
1p 0.5 0.95 8.3 66 65
2p 0.5 0.95 13.1 105 128
4p 0.5 0.95 15.6 125 189
8p 0.5 0.95 20.0 160 336
10p 0.5 0.95 21.6 173 404
12p 0.5 0.95 23.6 189 479
16p 0.5 0.95 26.1 209 616
20p 0.5 0.95 27.3 218 741
24p 0.5 0.95 29.2 234 877
27p 0.5 0.95 30.8 247 983
36p 0.5 0.95 34.8 278 1281
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 35
FC
FLEXIBLE
SHIPBOARD
FIRE RESISTANT
INDIVIDUAL & COLLECTIVE SCREENED
INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE
SHIPBOARD
FIRE RESISTANT
INDIVIDUAL & COLLECTIVE SCREENED
INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX.
PAIRS (p) DIAMETER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) (mm) RADIUS (kg/km)
AREA (mm2) NOMINAL (mm)
1p .75 1.20 9.4 76 83
2p .75 1.20 14.9 119 160
4p .75 1.20 17.8 142 236
8p .75 1.20 22.9 183 424
10p .75 1.20 24.7 198 509
12p .75 1.20 27.0 216 604
16p .75 1.20 29.8 239 779
20p .75 1.20 31.4 251 948
24p .75 1.20 33.6 269 1121
27p .75 1.20 35.3 282 1246
36p .75 1.20 40.0 320 1640
1p 1.0 1.30 10.5 84 103
2p 1.0 1.30 16.6 133 200
4p 1.0 1.30 20.1 161 303
8p 1.0 1.30 26.0 208 545
10p 1.0 1.30 28.3 227 666
12p 1.0 1.30 30.9 247 789
16p 1.0 1.30 34.2 274 1017
20p 1.0 1.30 35.8 287 1226
24p 1.0 1.30 38.3 307 1452
27p 1.0 1.30 40.4 324 1626
36p 1.0 1.30 45.8 367 2138
1p 1.5 1.50 10.8 86 117
2p 1.5 1.50 17.3 139 231
4p 1.5 1.50 20.5 164 349
8p 1.5 1.50 26.9 215 639
10p 1.5 1.50 29.3 234 783
12p 1.5 1.50 32.0 256 929
16p 1.5 1.50 35.4 283 1203
20p 1.5 1.50 37.3 298 1468
24p 1.5 1.50 39.9 319 1740
27p 1.5 1.50 42.1 336 1950
36p 1.5 1.50 47.7 381 2566
1p 2.5 2.10 12.3 98 157
2p 2.5 2.10 19.8 158 306
4p 2.5 2.10 23.8 190 472
8p 2.5 2.10 31.1 248 877
10p 2.5 2.10 33.9 271 1074
12p 2.5 2.10 37.0 296 1276
16p 2.5 2.10 40.9 327 1655
20p 2.5 2.10 43.0 344 2024
24p 2.5 2.10 46.0 368 2400
27p 2.5 2.10 48.6 389 2689
36p 2.5 2.10 55.0 440 3541
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX.
TRIADS (t) DIAMETER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) (mm) RADIUS (kg/km)
AREA (mm2) NOMINAL (mm)
1t 0.75 1.2 9.9 79 94
3t 0.75 1.2 16.4 131 233
4t 0.75 1.2 18.2 146 298
7t 0.75 1.2 22.0 176 479
1t 1.5 1.5 11.5 92 139
3t 1.5 1.5 19.3 154 352
4t 1.5 1.5 21.4 171 453
7t 1.5 1.5 26.1 209 748
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
36
FL
CONSTRUCTION
Conductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Flame Barrier: Fire Resistant, Halogen Free,
Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Overall Tape: Polyethylene Tape
Drain Wire: Tinned annealed copper
Screen: Individual and Collective
Aluminium/Laminate Tape
Overall Tape: Polyethylene
Braid/Armour Options:
Tinned Copper Wire Braid (90%)
Galvanized Steel Wire Braid (90%)
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
250 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, GL, USCG,
APPLICATION
Flexible Instrumentation cables suitable for all shipboard and marine applications, where circuit
integrity is required under fire conditions and mechanical or EMC protection is also required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-375
IEC 60331-11
IEC 60331-21
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
FLEXIBLE SHIPBOARD FIRE RESISTANT
INDIVIDUAL & COLLECTIVE SCREENED
BRAIDED/ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p 0.5 0.95 6.2 7.4 9.7 97 130
2p 0.5 0.95 10.9 12.1 14.9 149 265
4p 0.5 0.95 13.2 14.4 17.4 174 302
8p 0.5 0.95 17.2 18.4 21.5 215 475
10p 0.5 0.95 18.8 20.0 23.3 233 561
12p 0.5 0.95 20.6 21.8 25.3 253 650
16p 0.5 0.95 22.9 24.1 27.6 276 797
20p 0.5 0.95 24.1 25.3 29.0 290 937
24p 0.5 0.95 25.8 27.0 30.9 309 1086
27p 0.5 0.95 27.2 28.4 32.4 324 1194
36p 0.5 0.95 30.9 32.1 36.5 365 1530
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 37
FL
FLEXIBLE SHIPBOARD FIRE RESISTANT
INDIVIDUAL & COLLECTIVE SCREENED
BRAIDED/ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1t 0.75 1.20 6.5 9.3 11.8 118 178
3t 0.75 1.20 13.5 15.8 18.7 187 382
4t 0.75 1.20 15.1 17.4 20.6 206 466
7t 0.75 1.20 18.8 21.2 24.5 245 694
1t 1.5 1.50 7.9 10.8 13.3 133 233
3t 1.5 1.50 16.1 18.5 21.6 216 525
4t 1.5 1.50 18.1 20.4 23.7 237 648
7t 1.5 1.50 22.5 24.9 28.6 286 996
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p .75 1.20 7.1 8.4 10.7 107 153
2p .75 1.20 12.5 13.7 16.4 164 329
4p .75 1.20 15.2 16.4 19.3 193 360
8p .75 1.20 19.8 21.1 24.4 244 583
10p .75 1.20 21.7 22.9 26.4 264 691
12p .75 1.20 23.7 25.0 28.7 287 802
16p .75 1.20 26.4 27.6 31.6 316 997
20p .75 1.20 27.8 29.0 33.0 330 1167
24p .75 1.20 29.8 31.0 35.2 352 1355
27p .75 1.20 31.4 32.7 37.0 370 1502
36p .75 1.20 35.8 37.0 41.8 418 1929
1p 1.0 1.30 8.2 9.4 11.9 119 186
2p 1.0 1.30 14.2 15.4 18.3 183 417
4p 1.0 1.30 17.3 18.5 21.7 217 444
8p 1.0 1.30 22.8 24.0 27.5 275 728
10p 1.0 1.30 24.9 26.1 29.9 299 865
12p 1.0 1.30 27.3 28.5 32.5 325 1006
16p 1.0 1.30 30.4 31.6 35.7 357 1257
20p 1.0 1.30 32.0 33.2 37.6 376 1489
24p 1.0 1.30 34.3 35.5 40.1 401 1732
27p 1.0 1.30 36.2 37.4 42.2 422 1922
36p 1.0 1.30 41.2 42.4 47.6 476 2471
1p 1.5 1.50 8.5 9.7 12.2 122 203
2p 1.5 1.50 14.7 15.9 18.9 189 456
4p 1.5 1.50 18.0 19.2 22.5 225 503
8p 1.5 1.50 23.6 24.9 28.6 286 837
10p 1.5 1.50 25.9 27.1 31.0 310 998
12p 1.5 1.50 28.3 29.6 33.7 337 1164
16p 1.5 1.50 31.5 32.8 37.1 371 1463
20p 1.5 1.50 33.2 34.4 39.0 390 1742
24p 1.5 1.50 35.6 36.8 41.4 414 2020
27p 1.5 1.50 37.6 38.8 43.6 436 2245
36p 1.5 1.50 42.8 44.0 49.2 492 2899
1p 2.5 2.10 9.8 11.0 13.5 135 252
2p 2.5 2.10 16.9 18.2 21.3 213 594
4p 2.5 2.10 20.8 22.0 25.5 255 647
8p 2.5 2.10 27.4 28.6 32.6 326 1096
10p 2.5 2.10 30.0 31.2 35.4 354 1314
12p 2.5 2.10 32.9 34.1 38.5 385 1537
16p 2.5 2.10 36.6 37.8 42.6 426 1957
20p 2.5 2.10 38.6 39.8 44.8 448 2341
24p 2.5 2.10 41.4 42.6 47.8 478 2739
27p 2.5 2.10 43.7 44.9 50.3 503 3047
36p 2.5 2.10 49.7 51.0 56.8 568 3946
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
38
FLEXIBLE SHOREPOWER
0.6/1kV 110°C
EZ
CONSTRUCTION
Conductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Insulation: LSFLEX®R-30 (X-HF-110)
Cross-linked, Thermoset, Elastomeric,
Flame Retardant, Low Smoke, Zero Halogen
Splash resistant to oil, skydrol, petrol, acid,
sea water. Resists ozone and UV. Includes
ripcord on 10mm2 and larger.
Ripcord: High strength ripcord under
sheath..
Sheath: E-Rubber®N-40, Elastomeric Rubber,
Splash resistant to oil, skydrol, petrol, acid,
sea water. Resists ozone and UV.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
600/1000 Volts
CORE IDENTIFICATION
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPLICATION
Flexible Shorepower cables suitable for all shipboard and marine applications.
AS/NZS 1125
AS/NZS 5000.1
AS/NZS 3191
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) (mm) RADIUS (kg/km) (Amps)
AREA (mm2) NOMINAL (mm)
2c 1.5 1.50 9.1 36 83 29
2c 2.5 2.10 10.8 43 120 41
2c 4 2.50 11.8 47 161 55
2c 6 3.10 13.3 53 217 69
2c 10 4.10 17.6 70 378 95
2c 16 5.10 20.5 82 538 125
2c 25 6.40 24.3 97 800 170
2c 35 7.80 27.7 111 1071 205
*AS/NZS 3008, Table 11/14 (Fixed – Unenclosed spaced) 110°C operating temperature, 40°C ambient temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
FLEXIBLE SHOREPOWER
0.6/1kV 110°C
FLEXIBLE SHOREPOWER
0.6/1kV 110°C
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 39
EZ
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) (mm) RADIUS (kg/km) (Amps)
AREA (mm2) NOMINAL (mm)
3c 1.5 1.50 9.8 39 104 25
3c 2.5 2.10 11.3 45 148 35
3c 4 2.50 12.4 50 203 47
3c 6 3.10 14.2 57 281 59
3c 10 4.10 18.7 75 486 81
3c 16 5.10 21.8 87 696 105
3c 25 6.40 26.0 104 1051 145
3c 35 7.80 29.6 118 1414 175
3c 50 9.20 33.3 133 1942 215
3c 70 10.80 38.0 152 2607 270
3c 95 12.80 43.4 173 3490 335
3c 120 14.50 48.3 193 4324 390
3c 150 16.30 54.1 216 5403 445
3c 185 18.00 59.6 239 6647 510
3c 240 20.30 66.3 265 8466 610
3c 300 23.00 73.9 296 10476 700
4c 1.5 1.50 10.7 43 129 25
4c 2.5 2.10 12.4 50 185 35
4c 4 2.50 13.8 55 258 47
4c 6 3.10 15.8 63 358 59
4c 10 4.10 20.5 82 613 81
4c 16 5.10 23.9 96 880 105
4c 25 6.40 28.5 114 1333 145
4c 35 7.80 32.5 130 1795 175
4c 50 9.20 36.8 147 2486 215
4c 70 10.80 42.2 169 3351 270
4c 95 12.80 48.0 192 4485 335
4c 120 14.50 53.6 215 5567 390
4c 150 16.30 60.2 241 6965 445
4c 185 18.00 66.3 265 8562 510
4c 240 20.30 73.8 295 10927 610
4c 300 23.00 82.2 329 13504 700
4c 400 26.00 92.2 369 17647 810
5c 1.5 1.50 11.8 47 157 25
5c 2.5 2.10 13.9 56 229 35
5c 4 2.50 15.3 61 315 47
5c 6 3.10 17.4 70 436 59
5c 10 4.10 22.6 90 750 81
5c 16 5.10 26.4 105 1077 105
5c 25 6.40 31.7 127 1641 145
5c 35 7.80 36.3 145 2221 175
5c 50 9.20 41.1 164 3074 215
*AS/NZS 3008, Table 11/14 (Fixed – Unenclosed spaced) 110°C operating temperature, 40°C ambient temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommissions, etc., and reserves the right to modify specifications at any time
UP
CONSTRUCTION
Conductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV. Includes ripcord on
10mm2 and larger.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
600/1000 Volts
CORE COLOURS
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, BV, GL, RAN, USCG
APPLICATION
Flexible Single Insulated Power Cables suitable for all shipboard and marine applications
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
40
FLEXIBLE SHIPBOARD
SWITCHBOARD/PANEL WIRE
0.6/1kV 11C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) (mm) RADIUS (kg/km) (Amps)
AREA (mm2) NOMINAL (mm)
1c .75 1.20 2.7 11 12 16
1c 1.0 1.30 2.8 11 14 20
1c 1.5 1.50 3.0 12 19 26
1c 2.5 2.10 3.6 14 29 32
1c 4 2.50 4.0 16 43 43
1c 6 3.10 4.7 19 62 52
1c 10 4.10 5.7 23 104 72
1c 16 5.20 6.9 27 155 96
1c 25 6.40 8.5 34 243 127
1c 35 7.80 9.9 40 335 157
1c 50 9.20 11.5 46 477 196
1c 70 10.80 13.3 53 651 242
1c 95 12.80 15.3 61 883 293
1c 120 14.50 17.3 69 1098 339
1c 150 16.30 19.5 78 1375 389
1c 185 18.00 21.7 87 1701 444
1c 240 20.30 24.2 97 2191 522
1c 300 23.00 27.2 109 2712 601
1c 400 26.00 30.7 123 3580 670
1c 500 29.20 34.4 137 4529 720
1c 630 32.80 38.4 154 5698 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommissions, etc., and reserves the right to modify specifications at any time
OFFSHORE CABLES
P O W E R A N D C O N T R O L 1 1 0 º C
Braided/Armoured PJ 42
I N S T R U M E N T A T I O N 1 1 0 º C
Collective screened
Braided/Armoured RB 44
Individual and collective screened
Braided/Armoured FZ 46
P O W E R A N D C O N T R O L F i r e Re s i s t a n t 1 1 0 º C
Braided/Armoured HT 48
I N S T R U M E N T A T I O N F i r e R e s i s t a n t 1 1 0 º C
Collective screened
Braided/Armoured FK 50
Individual and collective screened
Braided/Armoured FE 52
S W I T C H B O A R D / PA N E L W I R E 1 1 0 º C
UP 54
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
42
PJ
CONSTRUCTION
Conductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV. Includes ripcord on
10mm2 and larger.
Ripcord: High strength ripcord under
bedding.
Bedding: LSFLEX®S-50 Low Smoke,
Zero Halogen (pressure extruded)
Braid/Armour Options:
Galvanized Steel Wire Braid (90%)
Tinned Copper Wire Braid (90%)
(Also available with drain wire under the braid)
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV. SHF-2 also available.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
600/1000 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, USCG, TC
APPLICATION
Flexible Power and Control cables suitable for all offshore applications, where mechanical
or EMC protection is required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
NEK 606
FLEXIBLE OFFSHORE
BRAIDED/ARMOURED POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km) (Amps)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1c 10 4.10 8.0 9.2 11.7 70 231 198
1c 16 5.10 9.2 10.4 12.9 77 299 264
1c 25 6.40 11.0 12.2 14.9 90 421 376
1c 35 7.80 12.4 13.7 16.4 98 535 491
1c 50 9.20 14.2 15.4 18.3 110 713 653
1c 70 10.80 16.0 17.2 20.4 122 922 857
1c 95 12.80 18.3 19.5 22.8 137 1201 1122
1c 120 14.50 20.2 21.4 24.8 149 1449 1370
1c 150 16.30 22.7 23.9 27.4 165 1781 1679
1c 185 18.00 25.0 26.2 30.0 180 2163 2043
1c 240 20.30 27.8 29.0 32.9 198 2719 2578
1c 300 23.00 30.9 32.2 36.5 219 3327 3151
1c 400 26.00 34.6 35.8 40.4 242 4287 4093
1c 500 29.20 38.5 39.7 44.7 268 5349 5111
1c 630 32.80 42.8 44.0 49.2 295 6632 6369
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 43
PJ
FLEXIBLE OFFSHORE
BRAIDED/ARMOURED POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE OFFSHORE
BRAIDED/ARMOURED POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km) (Amps)
AREA (mm2) (mm) (mm) NOMINAL (mm)
2c 1.5 1.50 8.3 9.5 12.0 72 182 20
2c 2.5 2.10 9.5 10.7 13.2 79 226 26
2c 4 2.50 10.6 11.8 14.5 87 281 34
2c 6 3.10 11.8 13.1 15.8 95 346 44
2c 10 4.10 14.1 15.3 18.2 109 488 61
2c 16 510 16.4 17.6 20.7 124 653 82
2c 25 6.40 19.8 21.0 24.3 146 931 108
2c 35 7.80 22.7 23.9 27.5 165 1213 133
3c 1.5 1.50 8.7 10.0 12.5 75 205 16
3c 2.5 2.10 10.1 11.3 13.8 83 259 21
3c 4 2.50 11.2 12.4 15.1 91 329 28
3c 6 3.10 12.5 13.8 16.5 99 413 36
3c 10 4.10 14.9 16.2 19.1 114 596 50
3c 16 5.10 17.6 18.8 22.0 132 819 67
3c 25 6.40 21.2 22.5 26.0 156 1192 89
3c 35 7.80 24.4 25.6 29.4 176 1566 110
3c 50 9.20 27.7 29.0 32.9 197 2106 137
3c 70 10.80 31.8 33.0 37.4 224 2784 169
3c 95 12.80 36.3 37.6 42.3 254 3668 205
3c 120 14.50 40.6 41.9 46.8 281 4495 237
3c 150 16.30 45.8 47.0 52.4 314 5581 272
3c 185 18.00 50.5 51.8 57.6 345 6810 311
3c 240 20.30 56.3 57.6 64.0 384 8629 365
4c 1.5 1.50 9.5 10.7 13.2 79 234 16
4c 2.5 2.10 11.2 12.4 15.1 91 311 21
4c 4 2.50 12.2 13.4 16.1 97 387 28
4c 6 3.10 13.9 15.1 18.1 108 504 36
4c 10 4.10 16.4 17.6 20.7 124 727 50
4c 16 5.10 19.3 20.6 23.9 143 1008 67
4c 25 6.40 23.4 24.6 28.3 170 1477 89
4c 35 7.80 26.9 28.1 32.1 192 1952 110
4c 50 9.20 30.6 32.2 36.6 220 2735 137
4c 70 10.80 35.4 36.6 41.1 247 3520 169
4c 95 12.80 40.4 41.6 46.6 279 4650 205
4c 120 14.50 45.4 46.6 52.0 312 5737 237
4c 150 16.30 50.9 52.1 57.9 348 7104 272
4c 185 18.00 56.4 57.6 64.0 384 8716 311
5c 1.5 1.50 10.6 11.8 14.5 87 277 16
5c 2.5 2.10 12.2 13.5 16.2 97 358 21
5c 4 2.50 13.4 14.6 17.5 105 455 28
5c 6 3.10 15.3 16.5 19.5 117 590 36
5c 10 4.10 18.3 19.5 22.8 137 876 50
5c 16 5.10 21.6 22.8 26.4 158 1218 67
5c 25 6.40 26.1 27.4 31.3 188 1792 89
5c 35 7.80 30.1 31.3 35.4 213 2373 110
5c 50 9.20 34.5 35.7 40.3 242 3247 137
5c 70 10.80 39.6 40.8 45.8 275 4310 169
5c 95 12.80 45.4 46.6 52.0 312 5716 205
5c 120 14.50 50.8 52.0 57.8 347 7032 237
5c 150 16.30 57.2 58.4 64.8 389 8749 272
5c 185 18.00 63.3 64.5 71.4 428 10710 311
5c 240 20.30 70.5 71.7 79.2 475 13590 365
7c 1.5 1.5 11.5 12.7 15.4 93 319 12
10c 1.5 1.5 14.5 15.8 18.7 112 433 11
12c 1.5 1.5 15.1 16.4 19.3 116 481 10
14c 1.5 1.5 15.9 17.1 20.2 121 537 10
16c 1.5 1.5 16.8 18.0 21.1 127 590 9
19c 1.5 1.5 17.9 19.1 22.2 133 670 9
21c 1.5 1.5 18.9 20.2 23.5 141 733 9
24c 1.5 1.5 21.0 22.2 25.7 154 837 9
27c 1.5 1.5 21.6 22.8 26.3 158 905 9
33c 1.5 1.5 23.2 24.4 28.2 169 1057 9
37c 1.5 1.5 24.3 25.5 29.3 176 1160 9
7c 2.5 2.1 13.3 14.6 17.5 105 425 21
10c 2.5 2.1 17.0 18.2 21.3 128 581 20
12c 2.5 2.1 17.9 19.1 22.2 133 659 18
14c 2.5 2.1 18.8 20.0 23.3 140 740 18
16c 2.5 2.1 19.9 21.1 24.4 147 817 16
19c 2.5 2.1 21.2 22.4 25.9 156 940 15
21c 2.5 2.1 22.4 23.7 27.2 163 1021 15
24c 2.5 2.1 24.8 26.0 29.8 179 1166 15
27c 2.5 2.1 25.5 26.7 30.5 183 1268 15
33c 2.5 2.1 27.7 28.9 32.9 197 1501 15
37c 2.5 2.1 28.8 30.0 34.2 205 1650 15
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
44
RB
CONSTRUCTION
Conductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Overall Tape: Polyethylene
Drain Wire: Tinned annealed copper
Screen: Aluminium/Laminate Tape
Ripcord: High strength ripcord under
bedding.
Bedding: LSFLEX®S-50 Low Smoke,
Zero Halogen (pressure extruded)
Braid/Armour Options:
Galvanized Steel Wire Braid (90%)
Tinned Copper Wire Braid (90%)
(Also available with drain wire under the braid)
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV. SHF-2 also available.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
250 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, USCG
APPLICATION
Flexible Instrumentation cables suitable for all offshore applications, where mechanical or
EMC protection is required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-375
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
NEK 606
FLEXIBLE
OFFSHORE
COLLECTIVE
SCREENED BRAIDED/ARMOURED
INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p 0.5 0.95 7.6 8.8 11.1 67 148
2p 0.5(quad form) 0.95 8.3 9.6 12.1 72 174
4p 0.5 0.95 12.2 13.4 16.1 97 266
8p 0.5 0.95 15.2 16.5 19.4 116 383
10p 0.5 0.95 16.4 17.6 20.7 124 438
12p 0.5 0.95 17.9 19.1 22.5 135 504
16p 0.5 0.95 19.6 20.8 24.1 145 593
20p 0.5 0.95 20.7 21.9 25.4 153 684
24p 0.5 0.95 21.9 23.1 26.7 160 766
27p 0.5 0.95 23.0 24.2 27.7 166 830
36p 0.5 0.95 25.9 27.1 31.1 186 1042
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
DEF(AUST) 5000
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 45
RB
FLEXIBLE
OFFSHORE
COLLECTIVE
SCREENED BRAIDED/ARMOURED
INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE
OFFSHORE
COLLECTIVE
SCREENED BRAIDED/ARMOURED
INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1t 0.75 1.20 8.5 9.7 12.2 73 179
3t 0.75 1.20 12.4 13.7 16.4 98 304
4t 0.75 1.20 13.5 14.8 17.7 106 358
7t 0.75 1.20 16.3 17.6 20.7 124 507
1t 1.5 1.50 9.9 11.1 13.6 81 233
3t 1.5 1.50 15.2 16.5 19.4 116 440
4t 1.5 1.50 16.6 17.8 21.0 126 527
7t 1.5 1.50 20.2 21.4 24.7 148 773
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p .75 1.20 8.1 9.3 11.8 71 167
2p .75(quad form) 1.20 8.9 10.2 12.7 76 196
4p .75 1.20 13.3 14.5 17.4 104 312
8p .75 1.20 16.7 17.9 21.0 126 461
10p .75 1.20 18.2 19.4 22.7 136 539
12p .75 1.20 19.7 20.9 24.2 145 607
16p .75 1.20 21.7 23.0 26.5 159 739
20p .75 1.20 22.7 24.0 27.5 165 841
24p .75 1.20 24.3 25.6 29.3 176 969
27p .75 1.20 25.5 26.7 30.5 183 1054
36p .75 1.20 28.8 30.0 34.2 205 1331
1p 1.0 1.30 9.0 10.2 12.7 76 194
2p 1.0(quad form) 1.30 10.0 11.2 13.7 82 232
4p 1.0 1.30 15.4 16.6 19.7 118 389
8p 1.0 1.30 19.4 20.7 24.0 144 584
10p 1.0 1.30 21.2 22.4 25.9 156 685
12p 1.0 1.30 22.9 24.2 27.7 166 774
16p 1.0 1.30 25.4 26.6 30.3 182 948
20p 1.0 1.30 26.6 27.8 31.7 190 1095
24p 1.0 1.30 28.4 29.7 33.8 203 1263
27p 1.0 1.30 29.8 31.1 35.2 211 1377
36p 1.0 1.30 33.7 34.9 39.5 237 1744
1p 1.5 1.50 9.4 10.6 13.1 79 212
2p 1.5(quad form) 1.50 10.7 11.9 14.6 88 270
4p 1.5 1.50 16.2 17.4 20.6 123 442
8p 1.5 1.50 20.8 22.0 25.6 153 699
10p 1.5 1.50 22.5 23.7 27.2 163 806
12p 1.5 1.50 24.6 25.8 29.5 177 936
16p 1.5 1.50 26.9 28.1 32.1 193 1145
20p 1.5 1.50 28.4 29.6 33.8 203 1345
24p 1.5 1.50 30.2 31.4 35.6 214 1535
27p 1.5 1.50 31.9 33.1 37.5 225 1704
36p 1.5 1.50 36.0 37.3 42.0 252 2170
1p 2.5 2.10 10.8 12.1 14.8 89 269
2p 2.5(quad form) 2.10 12.2 13.4 16.1 97 339
4p 2.5 2.10 19.0 20.2 23.5 141 585
8p 2.5 2.10 24.5 25.7 29.5 177 948
10p 2.5 2.10 26.5 27.7 31.7 190 1114
12p 2.5 2.10 29.0 30.2 34.4 206 1297
16p 2.5 2.10 32.0 33.3 37.6 226 1614
20p 2.5 2.10 33.6 34.8 39.4 236 1895
24p 2.5 2.10 36.0 37.2 42.0 252 2204
27p 2.5 2.10 38.0 39.2 44.0 264 2435
36p 2.5 2.10 42.9 44.1 49.3 296 3117
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
46
FZ
CONSTRUCTION
Conductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Overall Tape: Polyethylene
Drain Wire: Tinned annealed copper
Screen: Individual and Collective
Aluminium/Laminate Tape
Ripcord: High strength ripcord under
bedding.
Bedding: LSFLEX®F-10 Low Smoke,
Zero Halogen (pressure extruded)
Braid/Armour Options:
Galvanized Steel Wire Braid (90%)
Tinned Copper Wire Braid (90%)
(Also available with drain wire under the braid)
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV. SHF-2 also available.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
250 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, USCG
APPLICATION
Flexible Instrumentation cables suitable for all offshore applications, where mechanical or
EMC protection is required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-375
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
NEK 606
FLEXIBLE OFFSHORE INDIVIDUAL
& COLLECTIVE SCREENED BRAIDED/
ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p 0.5 0.95 7.6 8.8 11.1 67 148
2p 0.5 0.95 11.6 12.8 15.5 93 273
4p 0.5 0.95 13.5 14.7 17.6 106 321
8p 0.5 0.95 17.0 18.2 21.3 128 476
10p 0.5 0.95 18.5 19.8 23.1 138 558
12p 0.5 0.95 20.0 21.2 24.6 147 628
16p 0.5 0.95 22.1 23.4 26.9 161 768
20p 0.5 0.95 23.1 24.4 28.1 169 883
24p 0.5 0.95 24.8 26.0 29.8 179 1008
27p 0.5 0.95 26.0 27.2 31.2 187 1107
36p 0.5 0.95 29.3 30.5 34.7 208 1388
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
DEF(AUST) 5000
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 47
FZ
FLEXIBLE OFFSHORE INDIVIDUAL
& COLLECTIVE SCREENED BRAIDED/
ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE OFFSHORE INDIVIDUAL
& COLLECTIVE SCREENED BRAIDED/
ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1t 0.75 1.20 9.4 9.7 12.2 73 179
3t 0.75 1.20 15.7 14.8 17.7 106 351
4t 0.75 1.20 17.4 16.3 19.2 115 417
7t 0.75 1.20 21.0 19.3 22.7 136 603
1t 1.5 1.50 10.1 11.1 13.6 81 233
3t 1.5 1.50 17.0 17.6 20.7 124 496
4t 1.5 1.50 18.8 19.4 22.7 136 605
7t 1.5 1.50 22.7 23.2 26.7 160 890
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p .75 1.20 8.1 9.3 11.8 71 167
2p .75 1.20 12.4 13.7 16.4 98 311
4p .75 1.20 14.8 16.0 18.9 113 370
8p .75 1.20 18.6 19.9 23.2 139 566
10p .75 1.20 20.1 21.4 24.7 148 649
12p .75 1.20 22.0 23.2 26.7 160 751
16p .75 1.20 24.3 25.5 29.3 176 922
20p .75 1.20 25.4 26.6 30.4 182 1057
24p .75 1.20 27.0 28.2 32.2 193 1211
27p .75 1.20 28.5 29.8 33.9 204 1343
36p .75 1.20 32.2 33.4 37.8 227 1692
1p 1.0 1.30 9.0 10.2 12.7 76 194
2p 1.0 1.30 14.1 15.4 18.3 110 393
4p 1.0 1.30 16.3 17.6 20.7 124 448
8p 1.0 1.30 21.4 22.6 26.2 157 716
10p 1.0 1.30 23.1 24.4 28.1 169 834
12p 1.0 1.30 25.3 26.5 30.2 181 959
16p 1.0 1.30 27.9 29.2 33.1 199 1184
20p 1.0 1.30 29.2 30.5 34.6 208 1377
24p 1.0 1.30 31.3 32.5 36.9 221 1594
27p 1.0 1.30 32.9 34.1 38.4 231 1744
36p 1.0 1.30 37.1 38.3 43.1 259 2221
1p 1.5 1.50 9.4 10.6 13.1 79 212
2p 1.5 1.50 14.8 16.0 19.0 114 435
4p 1.5 1.50 17.7 18.9 22.0 132 515
8p 1.5 1.50 22.6 23.8 27.3 164 818
10p 1.5 1.50 24.6 25.8 29.6 177 969
12p 1.5 1.50 26.7 27.9 31.8 191 1115
16p 1.5 1.50 29.5 30.7 34.9 209 1386
20p 1.5 1.50 31.1 32.3 36.7 220 1634
24p 1.5 1.50 33.1 34.3 38.7 232 1873
27p 1.5 1.50 34.9 36.2 40.7 244 2080
36p 1.5 1.50 39.4 40.7 45.7 274 2658
1p 2.5 2.10 10.8 12.1 14.8 89 269
2p 2.5 2.10 16.9 18.1 21.2 127 561
4p 2.5 2.10 20.3 21.5 24.8 149 661
8p 2.5 2.10 26.3 27.5 31.4 189 1098
10p 2.5 2.10 28.7 29.9 34.0 204 1306
12p 2.5 2.10 31.3 32.5 36.9 221 1522
16p 2.5 2.10 34.6 35.8 40.4 242 1903
20p 2.5 2.10 36.3 37.5 42.3 254 2242
24p 2.5 2.10 38.8 40.0 45.0 270 2612
27p 2.5 2.10 40.8 42.0 47.0 282 2874
36p 2.5 2.10 46.3 47.5 53.1 319 3723
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
48
HT
CONSTRUCTION
Conductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Flame Barrier: Fire Resistant, Halogen Free,
Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV. Includes ripcord on
10mm2 and larger.
Ripcord: High strength ripcord under
bedding.
Bedding: LSFLEX®F-10 Low Smoke,
Zero Halogen (pressure extruded)
Braid/Armour Options:
Galvanized Steel Wire Braid (90%)
Tinned Copper Wire Braid (90%)
(Also available with drain wire under the braid)
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV. SHF-2 also available.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
600/1000 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, USCG
APPLICATION
Flexible Power and Control cables suitable for all offshore applications, where circuit integrity
is required under fire conditions and mechanical or EMC protection is also required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60331-11
IEC 60331-21
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
NEK 606
FLEXIBLE OFFSHORE FIRE RESISTANT
BRAIDED/ARMOURED POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km) (Amps)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1c 10 4.10 8.7 10.0 12.5 125 249 72
1c 16 5.10 9.9 11.1 13.6 136 320 96
1c 25 6.40 11.6 12.9 15.6 156 440 127
1c 35 7.80 13.1 14.3 17.2 172 561 157
1c 50 9.20 14.9 16.1 19.0 190 737 196
1c 70 10.80 16.8 18.0 21.1 211 953 242
1c 95 12.80 19.1 20.3 23.7 237 1240 293
1c 120 14.50 21.2 22.5 26.0 260 1509 339
1c 150 16.30 23.4 24.6 28.4 284 1833 389
1c 185 18.00 25.7 27.0 30.9 309 2219 444
1c 240 20.30 28.5 29.7 33.9 339 2780 522
1c 300 23.00 31.7 32.9 37.3 373 3384 601
1c 400 26.00 35.4 36.6 41.1 411 4349 670
1c 500 29.20 39.2 40.5 45.4 454 5418 720
1c 630 32.80 43.5 44.8 50.1 501 6722 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 49
HT
FLEXIBLE OFFSHORE FIRE RESISTANT
BRAIDED/ARMOURED POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE OFFSHORE FIRE RESISTANT
BRAIDED/ARMOURED POWER & CONTROL
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km) (Amps)
AREA (mm2) (mm) (mm) NOMINAL (mm)
2c 1.5 1.50 9.7 10.9 13.4 134 218 20
2c 2.5 2.10 11.2 12.4 15.1 151 277 26
2c 4 2.50 12.0 13.3 16.0 160 326 34
2c 6 3.10 13.3 14.5 17.4 174 399 44
2c 10 4.10 15.6 16.8 19.9 199 549 61
2c 16 5.10 18.1 19.3 22.6 226 727 82
2c 25 6.40 21.2 22.4 26.0 260 1002 108
2c 35 7.80 24.2 25.5 29.2 292 1294 133
3c 1.5 1.50 10.2 11.4 13.9 139 246 16
3c 2.5 2.10 11.8 13.1 15.8 158 316 21
3c 4 2.50 12.8 14.0 16.7 167 380 28
3c 6 3.10 14.3 15.6 18.5 185 480 36
3c 10 4.10 16.6 17.8 20.9 209 666 50
3c 16 5.10 19.2 20.4 23.7 237 896 67
3c 25 6.40 22.6 23.8 27.4 274 1255 89
3c 35 7.80 25.8 27.0 31.0 310 1648 110
3c 50 9.20 29.3 30.5 34.7 347 2201 137
3c 70 10.80 33.4 34.6 39.2 392 2906 169
3c 95 12.80 38.3 39.5 44.5 445 3833 205
3c 120 14.50 42.6 43.8 49.0 490 4684 237
3c 150 16.30 47.3 48.6 54.2 542 5755 272
3c 185 18.00 52.3 53.5 59.5 595 7017 311
3c 240 20.30 58.1 59.3 65.7 657 8839 365
4c 1.5 1.50 11.3 12.6 15.3 153 293 16
4c 2.5 2.10 12.9 14.1 17.1 171 371 21
4c 4 2.50 14.2 15.4 18.3 183 459 28
4c 6 3.10 15.7 16.9 20.0 200 576 36
4c 10 4.10 18.4 19.6 22.9 229 818 50
4c 16 5.10 21.3 22.5 26.1 261 1107 67
4c 25 6.40 25.1 26.3 30.1 301 1563 89
4c 35 7.80 28.7 29.9 34.1 341 2059 110
4c 50 9.20 32.5 33.8 38.1 381 2766 137
4c 70 10.80 37.1 38.3 43.1 431 3666 169
4c 95 12.80 42.6 43.8 49.0 490 4847 205
4c 120 14.50 47.3 48.6 54.2 542 5948 237
4c 150 16.30 52.8 54.1 60.1 601 7333 272
4c 185 18.00 58.3 59.5 66.0 660 8948 311
5c 1.5 1.50 12.4 13.7 16.4 164 335 16
5c 2.5 2.10 14.4 15.7 18.6 186 434 21
5c 4 2.50 15.6 16.8 19.9 199 540 28
5c 6 3.10 17.5 18.7 21.9 219 682 36
5c 10 4.10 20.3 21.5 24.9 249 967 50
5c 16 5.10 23.6 24.8 28.6 286 1326 67
5c 25 6.40 28.0 29.3 33.2 332 1893 89
5c 35 7.80 32.1 33.3 37.7 377 2499 110
5c 50 9.20 36.4 37.6 42.4 424 3380 137
5c 70 10.80 41.7 42.9 48.1 481 4500 169
5c 95 12.80 47.8 49.1 54.7 547 5952 205
5c 120 14.50 53.2 54.4 60.4 604 7303 237
5c 150 16.30 59.3 60.5 67.2 672 9024 272
5c 185 18.00 65.4 66.7 73.7 737 11010 311
5c 240 20.30 72.7 73.9 81.5 815 13921 365
7c 1.5 1.50 13.5 14.8 17.7 177 391 12
10c 1.5 1.50 17.5 18.7 21.8 218 540 11
12c 1.5 1.50 18.2 19.4 22.7 227 607 10
14c 1.5 1.50 19.1 20.3 23.7 237 671 10
16c 1.5 1.50 20.2 21.4 24.8 248 738 9
19c 1.5 1.50 21.5 22.7 26.3 263 845 9
21c 1.5 1.50 22.8 24.0 27.6 276 916 9
24c 1.5 1.50 25.2 26.4 30.2 302 1046 9
27c 1.5 1.50 26.0 27.2 31.1 311 1141 9
33c 1.5 1.50 28.2 29.4 33.6 336 1344 9
37c 1.5 1.50 29.3 30.5 34.7 347 1462 9
7c 2.5 2.10 15.7 17.0 20.1 201 510 21
10c 2.5 2.10 20.1 21.3 24.6 246 698 20
12c 2.5 2.10 21.1 22.4 25.9 259 798 18
14c 2.5 2.10 22.2 23.5 27.0 270 887 18
16c 2.5 2.10 23.5 24.8 28.5 285 988 16
19c 2.5 2.10 25.0 26.3 30.0 300 1126 15
21c 2.5 2.10 26.6 27.8 31.7 317 1233 15
24c 2.5 2.10 29.4 30.6 34.8 348 1407 15
27c 2.5 2.10 30.2 31.5 35.6 356 1529 15
33c 2.5 2.10 32.8 34.1 38.4 384 1808 15
37c 2.5 2.10 34.4 35.6 40.1 401 1998 15
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
50
FK
CONSTRUCTION
Conductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Flame Barrier: Fire Resistant, Halogen Free,
Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Overall Tape: Polyethylene
Drain Wire: Tinned annealed copper
Screen: Aluminium/Laminate Tape
Ripcord: High strength ripcord under
bedding.
Bedding: LSFLEX®F-10 Low Smoke,
Zero Halogen (pressure extruded)
Braid/Armour Options:
Galvanized Steel Wire Braid (90%)
Tinned Copper Wire Braid (90%)
(Also available with drain wire under the braid)
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV. SHF-2 also available.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
250 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, USCG
APPLICATION
Flexible Instrumentation cables suitable for all offshore applications, where circuit integrity is
required under fire conditions and mechanical or EMC protection is also required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-375
IEC 60331-11
IEC 60331-21
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
NEK 606
FLEXIBLE OFFSHORE FIRE RESISTANT
COLLECTIVE SCREENED
BRAIDED/ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p 0.5 0.95 8.5 9.7 12.2 122 175
2p 0.5(quad form) 0.95 9.4 10.7 13.2 132 205
4p 0.5 0.95 14.3 15.6 18.5 185 334
8p 0.5 0.95 18.1 19.3 22.6 226 498
10p 0.5 0.95 19.5 20.7 24.0 240 565
12p 0.5 0.95 21.3 22.5 26.0 260 652
16p 0.5 0.95 23.3 24.5 28.3 283 782
20p 0.5 0.95 24.6 25.8 29.6 296 897
24p 0.5 0.95 26.1 27.4 31.3 313 1020
27p 0.5 0.95 27.6 28.8 32.8 328 1119
36p 0.5 0.95 31.1 32.4 36.7 367 1409
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 51
FK
FLEXIBLE OFFSHORE FIRE RESISTANT
COLLECTIVE SCREENED
BRAIDED/ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE OFFSHORE FIRE RESISTANT
COLLECTIVE SCREENED
BRAIDED/ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1t 0.75 1.20 9.9 11.1 13.6 136 217
3t 0.75 1.20 15.3 16.5 19.4 194 395
4t 0.75 1.20 16.7 17.9 21.0 210 468
7t 0.75 1.20 20.2 21.5 24.8 248 670
1t 1.5 1.50 11.5 12.8 15.5 155 285
3t 1.5 1.50 18.2 19.4 22.7 227 551
4t 1.5 1.50 19.9 21.1 24.4 244 654
7t 1.5 1.50 24.4 25.6 29.3 293 981
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p .75 1.20 9.4 10.7 13.2 132 201
2p .75 (quad form) 1.20 10.7 12.0 14.7 147 249
4p .75 1.20 16.3 17.5 20.6 206 403
8p .75 1.20 20.9 22.1 25.7 257 622
10p .75 1.20 22.6 23.8 27.3 273 710
12p .75 1.20 24.7 25.9 29.6 296 821
16p .75 1.20 27.0 28.3 32.2 322 991
20p .75 1.20 28.5 29.8 33.9 339 1153
24p .75 1.20 30.4 31.6 35.7 357 1305
27p .75 1.20 32.1 33.3 37.6 376 1444
36p .75 1.20 36.2 37.4 42.2 422 1825
1p 1.0 1.30 10.7 11.9 14.6 146 242
2p 1.0 (quad form) 1.30 12.0 13.2 15.9 159 291
4p 1.0 1.30 18.6 19.9 23.2 232 491
8p 1.0 1.30 23.8 25.1 28.8 288 755
10p 1.0 1.30 26.0 27.2 31.2 312 886
12p 1.0 1.30 28.4 29.6 33.8 338 1024
16p 1.0 1.30 31.4 32.6 37.0 370 1253
20p 1.0 1.30 32.9 34.1 38.5 385 1435
24p 1.0 1.30 35.2 36.5 41.0 410 1655
27p 1.0 1.30 37.0 38.2 43.0 430 1818
36p 1.0 1.30 42.0 43.2 48.4 484 2314
1p 1.5 1.50 11.0 12.2 14.9 149 259
2p 1.5 (quad form) 1.50 12.4 13.6 16.3 163 320
4p 1.5 1.50 19.3 20.5 23.8 238 546
8p 1.5 1.50 24.9 26.1 29.9 299 868
10p 1.5 1.50 26.9 28.2 32.1 321 1013
12p 1.5 1.50 29.5 30.7 34.8 348 1176
16p 1.5 1.50 32.6 33.8 38.2 382 1452
20p 1.5 1.50 34.4 35.6 40.2 402 1703
24p 1.5 1.50 36.6 37.8 42.6 426 1957
27p 1.5 1.50 38.6 39.8 44.8 448 2170
36p 1.5 1.50 43.6 44.8 50.2 502 2759
1p 2.5 2.10 12.3 13.5 16.2 162 311
2p 2.5 (quad form) 2.10 14.2 15.4 18.3 183 406
4p 2.5 2.10 22.3 23.5 27.0 270 700
8p 2.5 2.10 28.9 30.1 34.3 343 1145
10p 2.5 2.10 31.5 32.7 37.1 371 1355
12p 2.5 2.10 34.4 35.7 40.2 402 1576
16p 2.5 2.10 38.1 39.3 44.1 441 1957
20p 2.5 2.10 39.9 41.2 46.2 462 2293
24p 2.5 2.10 42.8 44.0 49.2 492 2662
27p 2.5 2.10 45.1 46.4 51.8 518 2954
36p 2.5 2.10 51.0 52.2 58.0 580 3773
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
52
FE
CONSTRUCTION
Conductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Flame Barrier: Fire Resistant, Halogen Free,
Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Overall Tape: Polyethylene
Drain Wire: Tinned annealed copper
Screen: Individual and Collective
Aluminium/Laminate Tape
Ripcord: High strength ripcord under
bedding.
Bedding: LSFLEX®F-10 Low Smoke,
Zero Halogen (pressure extruded)
Braid/Armour Options:
Galvanized Steel Wire Braid (90%)
Tinned Copper Wire Braid (90%)
(Also available with drain wire under the braid)
Ripcord: High strength ripcord under sheath.
Sheath: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV. SHF-2 also available.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
250 Volts
CORE COLOURS
To customer specification
SHEATH COLOUR
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, USCG
APPLICATION
Flexible Instrumentation cables suitable for all offshore applications, where circuit integrity
is required under fire conditions and mechanical or EMC protection is also required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-375
IEC 60331-11
IEC 60331-21
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
NEK 606
FLEXIBLE OFFSHORE FIRE RESISTANT
INDIVIDUAL & COLLECTIVE SCREENED
BRAIDED/ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p 0.5 0.95 8.5 9.7 12.2 122 175
2p 0.5 0.95 13.1 14.3 17.3 173 328
4p 0.5 0.95 15.6 16.8 20.0 200 392
8p 0.5 0.95 19.8 21.0 24.4 244 591
10p 0.5 0.95 21.6 22.8 26.4 264 694
12p 0.5 0.95 23.4 24.6 28.3 283 792
16p 0.5 0.95 25.9 27.1 31.0 310 970
20p 0.5 0.95 27.1 28.3 32.2 322 1110
24p 0.5 0.95 29.0 30.2 34.4 344 1280
27p 0.5 0.95 30.4 31.6 35.8 358 1396
36p 0.5 0.95 34.6 35.8 40.3 403 1781
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 53
FE
FLEXIBLE OFFSHORE FIRE RESISTANT
INDIVIDUAL & COLLECTIVE SCREENED
BRAIDED/ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
FLEXIBLE OFFSHORE FIRE RESISTANT
INDIVIDUAL & COLLECTIVE SCREENED
BRAIDED/ARMOURED INSTRUMENTATION
250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1t 0.75 1.20 11.2 11.1 13.6 136 217
3t 0.75 1.20 18.9 17.7 20.8 208 445
4t 0.75 1.20 20.9 19.4 22.7 227 538
7t 0.75 1.20 25.2 23.2 26.8 268 774
1t 1.5 1.50 11.7 12.8 15.5 155 285
3t 1.5 1.50 19.9 20.5 23.8 238 605
4t 1.5 1.50 22.0 22.6 26.1 261 738
7t 1.5 1.50 26.7 27.2 31.1 311 1099
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL MINIMUM APPROX
PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER BENDING WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) RADIUS (kg/km)
AREA (mm2) (mm) (mm) NOMINAL (mm)
1p .75 1.20 9.4 10.7 13.2 132 201
2p .75 1.20 14.9 16.1 19.0 190 401
4p .75 1.20 17.8 19.0 22.1 221 465
8p .75 1.20 22.6 23.9 27.4 274 720
10p .75 1.20 24.7 25.9 29.7 297 847
12p .75 1.20 26.8 28.0 31.9 319 970
16p .75 1.20 29.6 30.9 35.0 350 1191
20p .75 1.20 31.2 32.5 36.8 368 1391
24p .75 1.20 33.2 34.4 39.0 390 1593
27p .75 1.20 35.1 36.3 40.9 409 1753
36p .75 1.20 39.6 40.8 45.8 458 2223
1p 1.0 1.30 10.7 11.9 14.6 146 242
2p 1.0 1.30 16.6 17.8 21.0 210 493
4p 1.0 1.30 19.6 20.8 24.2 242 554
8p 1.0 1.30 25.8 27.0 31.0 310 898
10p 1.0 1.30 28.1 29.4 33.5 335 1058
12p 1.0 1.30 30.5 31.7 35.9 359 1204
16p 1.0 1.30 33.8 35.0 39.6 396 1497
20p 1.0 1.30 35.6 36.8 41.4 414 1741
24p 1.0 1.30 38.1 39.3 44.1 441 2013
27p 1.0 1.30 40.0 41.3 46.2 462 2216
36p 1.0 1.30 45.4 46.7 52.0 520 2832
1p 1.5 1.50 11.0 12.2 14.9 149 259
2p 1.5 1.50 17.3 18.6 21.7 217 542
4p 1.5 1.50 20.8 22.0 25.5 255 631
8p 1.5 1.50 26.7 27.9 31.8 318 1003
10p 1.5 1.50 29.1 30.3 34.5 345 1188
12p 1.5 1.50 31.8 33.0 37.4 374 1380
16p 1.5 1.50 35.2 36.4 41.0 410 1712
20p 1.5 1.50 36.8 38.1 42.8 428 2001
24p 1.5 1.50 39.4 40.7 45.7 457 2322
27p 1.5 1.50 41.6 42.9 48.1 481 2576
36p 1.5 1.50 47.0 48.3 53.9 539 3286
1p 2.5 2.10 12.3 13.5 16.2 162 311
2p 2.5 2.10 19.6 20.8 24.1 241 685
4p 2.5 2.10 23.6 24.8 28.5 285 788
8p 2.5 2.10 30.9 32.1 36.4 364 1316
10p 2.5 2.10 33.5 34.7 39.2 392 1550
12p 2.5 2.10 36.5 37.8 42.5 425 1804
16p 2.5 2.10 40.5 41.7 46.7 467 2251
20p 2.5 2.10 42.6 43.9 49.0 490 2664
24p 2.5 2.10 45.6 46.9 52.2 522 3098
27p 2.5 2.10 48.2 49.4 55.0 550 3440
36p 2.5 2.10 54.6 55.8 62.1 621 4441
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
UP
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
54
CONSTRUCTION
Conductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV. Includes ripcord on
10mm2 and larger.
OPERATING TEMP
-40°C to +110°C
VOLTAGE RATING
600/1000 Volts
CORE COLOURS
To customer specification
STANDARDS
APPROVALS
LR, DNV, ABS, BV, USCG
APPLICATION
Flexible Single Insulated Power Cables suitable for all shipboard and marine applications
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60332-1
IEC 60332-3(A)
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
FLEXIBLE OFFSHORE SWITCHBOARD/
PANEL WIRE
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL MINIMUM APPROX. CURRENT
CONDUCTORS (c) DIAMETER DIAMETER BENDING WEIGHT RATING*
X CROSS SECTION (mm) (mm) RADIUS (kg/km) (Amps)
AREA (mm2) NOMINAL (mm)
1c .75 1.20 2.7 11 12 16
1c 1.0 1.30 2.8 11 14 20
1c 1.5 1.50 3.0 12 19 26
1c 2.5 2.10 3.6 14 29 32
1c 4 2.50 4.0 16 43 43
1c 6 3.10 4.7 19 62 52
1c 10 4.10 5.7 23 104 72
1c 16 5.20 6.9 27 155 96
1c 25 6.40 8.5 34 243 127
1c 35 7.80 9.9 40 335 157
1c 50 9.20 11.5 46 477 196
1c 70 10.80 13.3 53 651 242
1c 95 12.80 15.3 61 883 293
1c 120 14.50 17.3 69 1098 339
1c 150 16.30 19.5 78 1375 389
1c 185 18.00 21.7 87 1701 444
1c 240 20.30 24.2 97 2191 522
1c 300 23.00 27.2 109 2712 601
1c 400 26.00 30.7 123 3580 670
1c 500 29.20 34.4 137 4529 720
1c 630 32.80 38.4 154 5698 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.
Tricab Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
TECHNICAL
INFORMATION
Product Coding 56
Cable Stripping Recommendation 57
Installation Recommendation 60
Conductor Data 61
Current Carrying Capacities 62
Fire Performance Testing 63
Drum Handling Procedures 64
FLEXIBLE OFFSHORE SWITCHBOARD/
PANEL WIRE
0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
21 3 4 567 8 9
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
56
PRODUCT CODING
SHIPBOARD CABLE - PRODUCT CODES
1. PRODUCT SERIES
eg. (BV series)
(PJ series)
2. SHEATH TYPE
(Shipboard/Offshore
Cables only)
A = SHF-1
C = SHF-2
3. CORE COLOUR
CONFIGURATION
eg. PA = IEC 60092-350
4. BRAID/ARMOUR
P= Plain Copper Wire Braid
T= Tinned Copper Wire Braid
G= Galvanized Steel Wire Braid
L= Tinned Copper Wire Braid + drain wire
M= Galvanized Steel Wire Braid + drain wire
A = Aluminium Braid
R= Aluminium Laminate Tape
X= Not Applicable
5. CONDUCTOR
N= Plain Annealed Copper Wire
D= Tinned Annealed Copper Wire
6. NUMBER OF
CONDUCTORS/PAIRS/TRIADS
7. CORE TYPE
C= Power/Control
P= Pair
T= Triad
Q= Quad
8. CONDUCTOR
CROSS SECTION
AREA (mm2)
9. SHEATH COLOUR
OR= Orange
BK= Black
WH= White
GY= Grey
BR= Brown
RE= Red
BL= Blue
GN= Green
EA= Green/Yellow (Earth)
BVA-PA XN/3C1.5 BK
OFFSHORE CABLE - PRODUCT CODES
21 3 4 567 8 9
PJ C -PA GN/4 C 2.5 BK
Cable Stripping Recommendation
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 57
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
60
INSTALLATION RECOMMENDATION
CORRECTION FACTORS FOR CABLE CURRENT RATING
Bunching of cable
Where more than six cables are bunched together and
operating at their maximum capacity, a correction factor of 0.85
should be applied (assuming insufficient free air circulation).
Single core cables are exempted from this requirement
Ambient temperature
The maximum current ratings in this catalogue are based on an
ambient temperature of 45°C. For other ambient temperatures,
the correction factors shown below should be applied.
* Shorepower cable only
INSTALLATION
Cable runs should be fixed in straight lines as far as
practicable. The minimum bending radius for cable should be
selected in accordance with the table below.
The installation of cables across expansion joints in any
structure should be avoided. Where this is not feasible,
a loop of cable sufficient to accommodate the expansion of
the joint should be provided. The internal radius of the loop is
to be at least 12 times the overall diameter of the cable.
Cables should be installed away from heat sources as far as
practicable. If this cannot be avoided and there is possibility
of damage to the cable, then suitable shields, insulation or
other protective measures should be installed.
Cables are not to be coated or painted with materials
which may adversely affect their sheath or fire performance.
Cables should be installed away from sources of mechanical
damage, as far as is practicable. If this cannot be avoided the
cables should be protected with suitable metallic casing.
VOLTAGE DROP
When selecting cable size, consideration must be given to
voltage drop. Refer to formula and table below:
Vd = L x I mV/Am
1000
Where: Vd = voltage drop in volts
L = route length of cable in meters
I = current to be carried in amps
mV/Am = millivolts per ampere metre value
(the drop in voltage shall not exceed 5% of supply voltage)
CONDUCTOR SIZE - SHORT CIRCUIT RATING
The short circuit current ratings in this catalogue are based on
a one second duration. To calculate the maximum permissible
short circuit ratings, the following formula should be applied.
C = cross section area of conductor in mm2
t = short circuit time in seconds
MAXIMUM INSTALLATION TENSION
To calculate the maximum allowable tension of cables during
installation the following formula should be applied:
50 x C x Nc
C = cross section area of conductor in mm2
Nc = total number of cores
Maximum tension must not exceed 20,000N (kg = N/9.81)
* All information above is intended as a guide only
Unbraided all sizes 4X
Unbraided, fire resistant all sizes 8X
Braided all sizes 6X
Braided, fire resistant all sizes 10X
Nylon protected all sizes 15X
Cable Cable Minimum
Construction OD bending radius
(times cable OD)
35°C 40°C 45°C 50°C 55°C 60°C 65°C
90 1.10 1.05 1.00 0.94 0.88 0.82 0.74
110* 1.04 1.00 0.96 0.93 0.89 0.85 0.81
Maximum
conductor
temperature
°C
Ambient air temperature
0.5 - 65 --
0.75 - 99 --
1- 132 - 49.7
1.5 215 198 30.0 31.9
2.5 358 330 16.4 17.4
4572 528 10.2 10.8
6858 792 6.81 7.23
10 1430 1320 4.05 4.30
16 2288 2112 2.55 2.71
25 3575 3300 1.62 1.72
35 25005 4620 1.17 1.25
50 7150 6600 0.872 0.929
70 10010 9240 0.615 0.657
95 13585 12540 0.457 0.491
120 17150 15840 0.373 0.403
150 21450 19800 0.316 0.344
185 26455 24420 0.269 0.296
240 34320 31680 0.227 0.252
300 42900 39600 0.202 0.227
400 57200 52800 0.183 0.208
500 75100 66000 0.170 0.195
630 90090 83160 0.159 0.184
Cross Short Circuit Voltage Drop
Sectional Current at 50Hz
Area (Amps for (mV/Am)
(mm2)1 second)
90°C 110°C 90°C 110°C
C
x
143
t(900C) C
x
132
t(1100C)
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 61
CONDUCTOR DATA
* All information above is intended as a guide only
CONVERSION TABLE - CROSS-SECTIONAL AREA
AWG/MCM TO MM2
AWG mm2
20 0.519
18 0.823
16 1.31
14 2.08
12 3.31
10 5.26
8 8.37
6 13.30
4 21.15
2 33.62
1 42.41
1/0 53.49
2/0 67.43
3/0 85.01
4/0 107.2
MCM mm2
250 126.7
300 152.0
350 177.3
400 202.7
450 228.0
500 253.4
550 278.7
600 304.0
650 329.4
700 354.7
750 380.0
800 405.4
850 430.7
900 456.0
950 481.4
1000 506.7
1250 633.4
1500 760.0
1750 886.7
2000 1013.4
CONDUCTOR - CONSTRUCTION
Tricab uses very fine 0.3mm copper wires to ensure maximum
flexibility and ease of use. The following table from IEC 60228
provides a comparative analysis.
size (mm2) Tricab class 2 class 5 class 6
0.5 7 X 0.30 7 X 0.30 16 X 0.20 28 X 0.15
0.75 12 X 0.30 7 X 0.37 24 X 0.20 42 X 0.15
1 14 X 0.30 7 X 0.43 32 X 0.20 56 X 0.15
1.5 21 X 0.30 7 X 0.52 30 X 0.25 84 X 0.15
2.5 35 X 0.30 19 X 0.41 50 X 0.25 140 X 0.15
4 56 X 0.30 19 X 0.52 56 X 0.30 224 X 0.15
6 84 X 0.30 19 X 0.64 84 X 0.30 192 X 0.20
10 144 X 0.30 49 X 0.51 80 X 0.40 320 X 0.20
16 224 X 0.30 49 X 0.65 128 X 0.40 512 X 0.20
25 350 X 0.30 84 X 0.62 200 X 0.40 800 X 0.20
35 490 X 0.30 133 X 0.58 280 X 0.40 1120 X 0.20
50 707 X 0.30 133 X 0.69 400 X 0.40 705 X 0.30
70 980 X 0.30 189 X 0.69 356 X 0.50 999 X 0.30
95 1344 X 0.30 259 X 0.69 485 X 0.50 1340 X 0.30
120 1672 X 0.30 336 X 0.67 614 X 0.50 1699 X 0.30
150 2090 X 0.30 592 X 0.69 765 X 0.50 2123 X 0.40
185 2584 X 0.30 494 X 0.69 994 X 0.50 1470 X 0.40
240 3344 X 0.30 627 X 0.70 1125 X 0.50 1905 X 0.40
300 4144 X 0.30 61 X 2.50 1530 X 0.50 2385 X 0.40
400 5488 X 0.30 61 X 2.89 2035 X 0.50 3200 X 0.40
500 6944X 0.30 61 X 3.20 1768 X 0.50 4010 X 0.40
630 8736 X 0.30 59 X 3.70 3200 X 0.50 5020 X 0.40
CONDUCTOR - DC RESISTANCE
To calculate the DC Resistance of copper conductors for a given
temperature (°C), the resistance at 20°C, as detailed must be
multiplied by the appropriate correction factor below.
AMBIENT Correction
Temperature Factor
(°C)
20 1.000
25 1.020
30 1.039
35 1.059
40 1.079
45 1.098
50 1.118
55 1.138
60 1.157
65 1.177
70 1.196
75 1.216
80 1.236
85 1.255
90 1.275
OVERALL DIAMETER OF CABLE
EXCEEDING NOT EXCEEDING
(mm) (mm)
NON-ARMOURED
CABLES
(mm)
ARMOURED
CABLES
(mm)
-8200 250
6 13 250 300
13 20 300 350
20 30 350 400
30 - 400 450
normal Maximum resistance of
cross- conductor at 20°C
sectional
Area plain copper Tinned Copper
(mm2) Ohm/Km Ohm/Km
0.5 39.0 40.1
0.75 26.0 26.7
1 19.5 20.0
1.5 13.3 13.7
2.5 7.98 8.21
4 4.95 5.09
6 3.30 3.39
10 1.91 1.95
16 1.21 1.24
25 0.780 0.795
35 0.554 0.565
50 0.386 0.393
70 0.272 0.277
95 0.206 0.210
120 0.161 0.164
150 0.129 0.132
185 0.106 0.108
240 0.0801 0.0817
300 0.0641 0.0654
400 0.0486 0.0495
500 0.0384 0.0391
630 0.0287 0.0292
SECURING OF CABLES
Cables should be effectively supported and secured
using flame retardant clips, saddles or straps. Special
care should be taken to avoid any damage caused by
excessive tensioning during installation.
The distance between fixing points should be
selected according to cable type and probability of
vibration, but should not exceed 450mm.
Where cables are installed below cable trays, ladder
or supports, the fixing distance for securing the cable
should be in accordance with the table below.
CURRENT CARRYING CAPACITIES
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
62
Nominal cross-
sectional area
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
Single core
A
23
40
51
52
72
96
127
157
196
242
293
339
389
444
522
601
d.c. a.c.
690
780
890
670
720
780
587
663
757
570
612
663
483
546
623
469
504
546
2 core
A
20
26
34
44
61
82
108
133
167
208
249
288
331
377
444
511
d.c. a.c.
3 or 4 core
A
16
21
28
36
50
67
89
110
137
169
205
237
272
311
365
421
d.c. a.c.
Table B.4 - Current carrying capacities in continuous service at
maximum rated conductor temperature of 90°C
Current carrying capacity
Ambient air temperature: 45°C
FIRE PERFORMANCE TESTING -
(IEC 60332-3, AS/NZS 1660.5.1) (IEC 60331, AS/NZS 1660.5.5)
(IEC 60754-1&2, AS/NZS 1660.5.3) (IEC 60134-1&2, AS/NZS 1660.5.2)
IEC 60331, AS/NZS 1660.5.5 - FIRE TEST
This test is conducted by mounting a 1200mm length of cable over a gas burner and energizing it to its rated
voltage. Flames are applied for 90 minutes at a temperature of at least 750°C. After 90 minutes the gas is
turned off. After a further 15 minutes the power is disconnected. To pass the requirements of this test, the
cable must remain operational both during the 90 minute exposure and the 15 minute cooling period.
IEC 60332-3, AS/NZS 1660.5.1 - FLAME RETARDANT TEST
This test is conducted by placing cables together on a vertical ladder
tray and then exposing them to the flames of a ribbon burner for the
appropriate time (Detailed below).
After removal of the flame, the cables are wiped clean and the
charring should not have exceeded 2.5 metres.
Category A:
7 litres of combustible material exposed to flame for 40 minutes
Category B:
3.5 litres of combustible material exposed to flame for 40 minutes
Category C:
1.5 litres of combustible material exposed to flame for 20 minutes
IEC 60754-1&2, AS/NZS 1660.5.3 - ACID GAS EMISSION TEST
This test determines the amount of acid gas emitted by burning cables.
IEC 61034-1&2, AS/NZS 1660.5.2 - SMOKE DENSITY TEST
This test measures the smoke emission from cables during fire.
This test is carried out in a 3m cubed enclosure where a cable sample is subjected to fire. The smoke emission and
density are measured by a light beam emitted across the inside of the enclosure to a photocell, measuring the amount
of luminous transmission received.
I S S U E 1 . 0 T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 63
Cradle both reel
flanges between
forks.
Do not lift by top
flange, cable or reel
will be damaged
Use a spreader bar to
prevent bending the
reel flanges and
mashing the cable.
Upended heavy reels will
often arrive damaged.
Refuse or receive
subject to inspection
for hidden damage.
Never drop reels.
Never allow fork
tynes to touch cable
surface or reel wrap.
Reels can be hoisted
with a shaft extended
through both flanges.
Place spacers under
the bottom flange and
between reels to
create a space to
insert the forks
Lower reels from
truck using hydraulic
gate, hoist or fork lift,
LOWER CAREFULLY.
Always load with
flanges on edge and
chock and block
securely.
RECOMMENDED CABLE DRUM HANDLING PROCEDURES
T R I C A B F L E X I B L E I E C L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 1 . 0
64