INDUPRIG UPR_installation_guide UPR Installation Guide
SRS_UPR_installation_guide SRS_UPR_installation_guide
User Manual: UPR_installation_guide
Open the PDF directly: View PDF .
Page Count: 4
Installation Guide
UPR - Universal Proximity Reader
Unit 1, AMC Business Park
12 Cumberland Avenue
Park Royal, London, NW10 7QL
t : 0208 621 6210
e : sales@doorentrydirect.com
w : www.doorentrydirect.com
80mm
16mm
58mm
1 Surface mount option - fixing and Installation
The Universal Proximity Reader should be fitted close to the door through which
a) Remove the front cover from the reader using a thin slot screwdriver
b) Drill 2 holes into the wall for the self-tapping screws and 1 hole for the cable
c) Thread the cable through the cable hole
d) Fix the reader firmly onto the wall with 2 self-tapping screws
e) Place the clipping front cover
you wish to control access.
13.5mm
53mm
70mm
40mm
40mm
3mm
2 Panel mount option - fixing and Installation
The Universal Proximity Reader should be fitted inside a panel with
a) Remove the front plate from the entry panel
b) The reader should easily slide on to studs on 40mm x 40mm cut out
c) Secure reader with fixings supplied with entry panel
40mm x 40mm cutout
3 Connections Diagram
Black
Red
White
Green
Blue
Yellow
0V DC
12V DC
D1
D0
LED
Tone
Power Supply 0V DC
Power Supply 12V DC
Control for Tone (require 0V DC)
Control for LED (require 0V DC)
Wiegand Data 1
Wiegand Data 0