(10–20 kVA/kW) Parallelable up to 400 kVA/kW PowerWAVE 8000DPA Modular UPS designed for low and medium power applications. PowerWAVE 8000DPA Capacities from 10 kVA/kW to 200 kVA/kW in 10 kVA/kW or 20 kVA/kW modular steps Parallelable frames up to 400 kVA/kW Available as tower (ST) or 19” rack-mountable (RI) solutions Fully rated output power (blade friendly); 20 kVA = 20kW N+1 redundancy up to 180 kVA/kW N+1 in a single frame ‘Six nines’ (99.9999%) availability Key benefits Individual static switches per module Each module has its own display and controller Each module has its own control logic Separate or common battery configuration Ideal for low to medium, high-density critical power protection applications. Three-phase UPS built for low to medium, high-density power protection applications. Leading-edge modular design using proven decentralised parallel architecture (DPA) technology. The PowerWAVE 8000DPA offers incredible energy efficiency, 99.9999% availability and flexible scalability in either a tower or rack-mountable solution. Up to 95.5% efficiency across a wide load range Near unity input power factor at partial and full loads (PF=0.99 @ 100% load) Low input harmonic distortion (THDi<3%) The right solution PowerWAVE 8000DPA is available in two versions Advanced Decentralised Parallel Architecture (DPA) Easy to replace ‘hot-swap’ modules Distributed control and power PowerWAVE 8000DPA ST (tower) is available for high-density applications requiring a standard power protection solution including frame, UPS, battery and communication. This solution delivers power protection from 10–200 kVA/KW (180 kVA/KW N+1) in 10 kVA/KW or 20 kVA/KW modular steps to provide a maximum power density of 472 kW/m2. PowerWAVE 8000DPA cabinet can be paralleled horizontally to increase the capacity up to 400 kVA/kW. Independent hot-swap modules Replace or add modules with no downtime The PowerWAVE 8000DPA RI (19” rackmountable) solution includes UPS, battery and communication, which can be integrated into any 19” rack (independent of manufacturer) and provides up to 80 kVA/KW (60 kVA/KW N+1) making it ideal for integrated IT, telecom or other applications. PowerWAVE 8000DPA ST (tower) Up to 10 UPS modules Slot for optional SNMP card Customer inputs and volt-free outputs / RS232 serial interface Maintenance bypass switch Parallel interface AC input terminals AC output terminals Battery terminal rail Earth bar No single points of failure Cost effective scalability & ‘right sizing’ Simple power upgrade Decentralised Parallel Architecture (DPA) means each UPS module contains all the hardware and software required for full-system operation. They share no common components so a DPA parallel system offers extremely high availability. In addition, potential single points of failure are eliminated and system uptime is maximised. PowerWAVE 8000DPA UPS modules can be paralleled to provide redundancy (parallel redundancy) or to increase the system’s total capacity. Future proof investment True ‘hot-swap’ modularity enables the safe removal and/or insertion of UPS modules into a PowerWAVE 8000DPA system without risk to the critical load and without the need to either transfer the critical load onto raw mains or remove power from the critical load. This directly addresses today’s requirement for continuous uptime, reducing mean time to repair (MTTR). High reliability Blade friendly Generator friendly Reliability maximised Supports blade servers Generator compatible Automatic parallel redundant operation Supports leading power factors Soft start – introduces the generator load in steps Parallel redundant (N+1) UPS systems provide the highest level of reliability by ensuring that the number of UPS modules in a system is a minimum of one (N) over and above the number required (N) to fully support the critical load. Blade servers typically have a leading power factor, which can present problems to UPS systems, particularly if they are not designed to power such loads. The PowerWAVE 8000DPA is designed to power all types of electrical loads, including blade servers. It can provide fully rated output power to power factors in the range of 0.9 leading to 0.8 lagging. The PowerWAVE 8000DPA is designed to automatically operate as a parallel redundant system, ensuring that the critical load always receives the highest level of power protection. PowerWAVE 8000DPA RI (19” rack-mountable) UPS modules Internal battery storage RS232 serial interface Customer inputs and volt-free outputs Maintenance bypass switch Slot for optional SNMP card Battery fuses The PowerWAVE 8000DPA offers a highly effective solution when introducing a generator to the critical load. If the load exceeds 50 per cent of the generator’s standby rating, switching the load in a single step presents a number of dangers. To negate this, each of the ‘hot-swap’ modules within the PowerWAVE 8000DPA’s modular frame come equipped with ‘soft start’ capability. This allows the modules to be switched on sequentially, introducing the generator to the load in more manageable steps. Class-leading energy efficiency – low total cost of ownership Very high operating efficiency Additionally, PowerWAVE 8000DPA has a near unity input power factor at full load (and even partial loads) reducing the size of the input cable and fuses, thereby saving on materials and costs. Reduced installation and upgrade costs Near unity input power factor and low input (THDi) – reduces running costs The PowerWAVE 8000DPA delivers class-leading efficiency of up to 95.5% across a wide load range significantly reducing system running costs and site air conditioning costs. Input current total harmonic distortion (THDi) of less than 3% virtually eliminates harmonic distortion of the mains supply. This saves unnecessary oversizing of gen-sets, cabling and circuit breakers; avoids extra heating of input transformers; and extends the overall lifetime of all input components. All these benefits ensure that the PowerWAVE 8000DPA offers one of the lowest ‘total cost of ownerships’ and smallest carbon footprints of any UPS system in its class. Input power factor versus load (Leading) 1 0.96 0.985 25% 50% 0.99 0.99 75% 100% Input power factor 0.8 PowerWAVE 8000DPA has a near unity input power factor at full load (and even partial loads) reducing the size of the input cable and fuses, thereby saving on materials and costs. 0.6 0.4 0.2 0 Load (%) Input current distortion THDi Input current total harmonic distortion (THDi) of <3% virtually eliminates harmonic distortion of the mains supply. 6.0 5.5 Input THDi % 5.0 4.5 4.0 4.0 3.7 3.4 3.5 3.0 3.0 2.5 2.0 1.5 25% 50% Load (%) 75% 100% Reduced TCO – AC–AC efficiency 97 95.5 95.5 96 95 Efficiency (%) 95 94.5 94 The PowerWAVE 8000DPA’s 95.5% true online efficiency significantly reduces system running costs and site air-conditioning costs. This helps reduce the organisation’s carbon footprint. *Depending on configuration. 93 92 91 90 25% 50% Load (%) 75% 100% Blade server friendly power 25 Power (kW versus KVA) -0.80 1.00 0.80 20 Designed to power all types of electrical loads including blade servers, the PowerWAVE 8000DPA can provide fully rated output power from 0.9 leading to 0.8 lagging. Additional kW *Depending on battery configuration. 15 10 Constant kW 5 0 -0.75 -0.80 -0.85 -0.90 -0.95 1.00 0.95 0.90 0.85 0.80 0.75 0.70 0.65 kW PowerWAVE 8000DPA ST ST tower range – 10-200 kVA/kW ST 40 – 2 modules ST 80 – 4 modules ST 60 – 3 modules ST 120 – 6 modules ST 200 – 10 modules Dimensions WxHxD: 550 x 1135 x 775 mm Dimensions WxHxD: 550 x 1135 x 775 mm Dimensions WxHxD: 550 x 1975 x 775 mm Dimensions WxHxD: 550 x1 975 x 775 mm Dimensions WxHxD: 550 x 1975 x 775 mm No. of internal batteries: 2 x 40 x 7.2/9Ah Total 80 blocks External battery ONLY No. of internal batteries: 3 x (2x40) x 7.2/9Ah Total 240 blocks External battery ONLY External battery ONLY PowerWAVE 8000DPA RI 19” rack-mountable range – 10-80 kVA/kW With batteries RI 11 – 1 module RI 12 – 1 module RI 22 – 2 modules RI24 – 2 modules Dimensions WxHxD: 488 x 487 x 735 mm (11 HU) Dimensions WxHxD: 488 x 665 x 735 mm (15 HU) Dimensions WxHxD: 488 x 798 x 735 mm (18 HU) Dimensions WxHxD: 488 x1153 x 735 mm (26 HU) Number of batteries: 40 Number of batteries: 80 Number of batteries: 80 Number of batteries: 160 Without batteries RI 10 – 1 module RI 20 – 2 modules RI 40 – 4 modules Dimensions WxHxD: 488 x 310 x 565 mm (7 HU) Dimensions WxHxD: 488 x 440 x 565 mm (10 HU) Dimensions WxHxD: 488 x 798 x 735 mm (18 HU) UK product catalogue V2 Sept 17 Uninterruptible Power Supplies Ltd, Woodgate, Bartley Wood Business Park, Hook, Hampshire RG27 9XA Tel: 01256 386700 ISO 9001 UKAS ACCREDITED Fax: 01256 386701 Email: sales@upspower.co.uk
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 7 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:4a0d334b-d484-11f2-0000-c9276ca0f65e Producer : GPL Ghostscript 9.20 Modify Date : 2017:09:18 13:51:43+02:00 Create Date : 2017:09:18 13:51:43+02:00 Creator Tool : Adobe InDesign CC 2017 (Macintosh) Document ID : uuid:4a0d334b-d484-11f2-0000-c9276ca0f65e Format : application/pdf Title : Untitled Creator : Adobe InDesign CC 2017 (Macintosh)EXIF Metadata provided by EXIF.tools