Installation Guide UFA 150, 200 Ultrasonic Sensor UFA150 UFA200
User Manual:
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
INSTALLATION GUIDE Ultrasonic Sensors Series UFA-150, UFA-200 For further information please see the data sheet at www.waycon.biz/products/ultrasonic-sensors/ FIRST STEPS WayCon Positionsmesstechnik GmbH would like to thank you for the trust you have placed in us and our products. This manual will make you familiar with the installation and operation of our ultrasonic sensors. Please read this manual carefully before initial operation! Unpacking and checking: Carefully lift the device out of the box by grabbing the housing. After unpacking the device, check it for any visible damage as a result of rough handling during the shipment. Check the delivery for completeness. If necessary consult the transportation company, or contact WayCon directly. MOUNTING THE SENSOR The sensor can be mounted with the two M12 nuts (HEX 17) which are included in the delivery. Ultrasonic sensors may be installed in any position, as long as depositions like dust, spray mist, or condensing humidity are avoided on the sound active membrane. In case several ultrasonic sensors are used in one application, it is important to leave sufficient distance between them. Otherwise the sensors may interact which leads to false measurement values. By using a sound deflection angle the sound beam can be redirected, at the expense of the sensor's maximum measurement range. A plain and hard surface should be used for the defection of the sound beam. Redirecting the sound beam with multiple sound deflection angles should be avoided. ELECTRICAL CONNECTION Function Connector M12 +24 V Pin 1 Teach-In Pin 2 0V Pin 3 Analog / OUT PNP Pin 4 INSTALLATION GUIDE Ultrasonic Sensors Series UFA-150, UFA-200 For further information please see the data sheet at www.waycon.biz/products/ultrasonic-sensors/ TECHNICAL DRAWING UFA-200 UFA-150-FB UFA-150-CP SOUND CONE GEOMETRY The exact geometry of the sound cone depends on the air-pressure, temperature, humidity and the size of the target. Smooth surfaces can be detected up to an inclination angle of 10°. However rough and structured (granular) surfaces can be detected up to higher angles. UFA-200 Blind Range UFA-150-FB UFA-150-CP Blind Range TEACH-IN GUIDE Ultrasonic Sensors Series UFA-150, UFA-200 For further information please see the data sheet at www.waycon.biz/products/ultrasonic-sensors/ ANALOG OUTPUT UFA...CU / CI The two measuring limits are set by connecting the teach wire with either the power supply -UB (0 V) or +UB (+24 VDC). The voltage must be active for at least 1 s on the teach wire. During teaching the LED shows if the sensor has detected the object. With -UB the lower measuring limit (0 V or 4 mA) and with +UB the upper measuring limit (10 V or 20 mA) is taught. Thus it is possible to teach a rising or a falling ramp. ● Place the object to the lower measuring limit (where 0 V or 4 mA is expected) ● Teach lower measuring limit with -UB ● Place the object to the upper measuring limit (where 10 v or 20 mA is expected) ● Teach upper measuring limit with +UB Upper and lower measuring limits can be reprogrammed at any time. Attention: The teach wire must not be connected during normal operation. The sensor can therefore be operated after teaching with a 3 wire cable. LED red LED yellow off blinking blinking off During teach-in: - Object detected - No object detected - Object not reliably detected on off Normal operation PNP off sw itching status Normal operation analogue off on Error on last status SWITCHING OUTPUT Window operation closer NO: Window operation opener NC: ● Set target to near switching point ● Set target to near switching point ● Teach switching point with -UB ● Teach switching target at with +UB ● Set target to far switching point ● Set target to far switching point ● Teach switching point with +UB ● Teach switching point with -UB Switching point closer NO: Switching point opener NC: ● Set target to switching point ● Set target to switching point ● Teach switching point with +UB ● Teach switching point with -UB ● Point sensor at space (>1.5 m) ● Point sensor at space (>1.5 m) ● Teach with -UB ● Teach with +UB RETROFLECTIVE MODE TEACH-IN GUIDE Ultrasonic Sensors Series UFA-150, UFA-200 For further information please see the data sheet at www.waycon.biz/products/ultrasonic-sensors/ VERSION WITH FOCUSING DEVICE UFA-150-FB UFA-200 Sound beam dashed line solid line Beam Ø at 0 mm ca. 3 mm ca. 9 mm Maximum beam Ø ca. 15 mm ca. 23 mm CHEMICAL RESISTANT VERSION NOTES Warning These devices are not designed for critical safety or emergency shut-down purposes. Therefore they should never be used in an application, where a malfunction of the device could cause personal injury. Environmental Influences Ultrasonic sensors are made for the use in atmospheric air. Environmental Influences like rain, snow, dust or smoke have no influence on the accuracy of the measurement. However, measurements under pressure (higher that the atmospheric pressure) are not possible with ultrasound sensors. Strong wind or air turbulences may lead to instability in measurement values. A flow speed up to a few m/s is unproblematic and will have no influence on the sensor's accuracy. Target Influences Liquids are excellently detectable with ultra sound. A classic application for ultrasonic sensors is level measurement. The sound beam axis however must have a maximum deviation of 3° vertically to the liquid level (no strong waves), otherwise the reflected sound will miss the sensor. Hot Targets with high temperatures cause a thermal convection in the surrounding air. For this reason the sound beam may be strongly diverted vertically to it's axis, so that the echo is weakened, or can no longer be received at all. For convex (cylindrical and spherical) surfaces, every area element has a different angle to the sound cone’s axis. The reflected cone thus diverges and the portion of the sound energy reflected to the receiver is reduced correspondingly. The maximum range decreases with the decreasing size of the cylinder (ball). The roughness and surface structures of the object to be detected also determine the scanning capacities of the ultrasonic sensors. Surface structures that are larger than the ultrasound wavelength, as well as coarse-grained bulk materials, reflect ultrasound in a scattered manner, and are not detected optimally by the sensor under these conditions. Hard material reflects almost all of the impulse energy from ultrasound applications in a way that makes them very easy to detect with ultrasound. Soft material, on the other hand, absorbs almost all of the impulse energy. It is thus harder to detect with ultrasound. These materials include felt, cotton, coarse meshes, foam, etc. Thin-walled foils behave like soft materials. To be able to use ultrasound, the foil thickness should be at least 0.01 mm. ACCESSORIES Cable w ith m ating connector M12, 4 pole, s hie lde d K4P2M-S-M12 2 m, straight connector, IP67 K4P5M-S-M12 5 m, straight connector, IP67 K4P10M-S-M12 10 m, straight connector, IP67 K4P2M-SW-M12 2 m, angular connector, IP67 K4P5M-SW-M12 5 m, angular connector, IP67 K4P10M-SW-M12 10 m, angular connector, IP67 PIN Cable colour 1 brow n 2 w hite 3 blue 4 black DECLARATION OF EC-CONFORMITY Based on: EN 60947-5-2 + amendments (proximity switches) EN 60947-5-7 + amendments (proximity sensors with analogue output) This is to certify that the following products correspond to the mentioned specifications. Classification Series Ultrasonic Sensors UFA-150, UFA-200 Test on immunity IEC 61000-6-2 (Industry) Type of test applied harmonized standards: EN 61000-4-2, EN 61000-4-3, EN 61000-4-4 The declaration of conformity loses its validity if the product is misused or modified without proper authorisation. Taufkirchen, 13.03.2013 Andreas Täger CEO
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 8 Tagged PDF : Yes Title : Installation Guide UFA-150, UFA-200 Author : Marcus Venghaus Subject : Ultrasonic sensor - Series UFA Keywords : ultrasound, ultrasonic, sensor, transducer, sound cone Creator : Impress Producer : OpenOffice 4.1.2 Create Date : 2016:12:08 08:39:55+01:00EXIF Metadata provided by EXIF.tools