INSTALLATION GUIDE
Ultrasonic Sensors Series UFP
For further information please see the data sheet at www.waycon.biz/products/ultrasonic-sensors/

FIRST STEPS
WayCon Positionsmesstechnik GmbH would like to thank you for the trust you have placed in us and our
products. This manual will make you familiar with the installation and operation of our ultrasonic sensors.
Please read this manual carefully before initial operation!
Unpacking and checking:
Carefully lift the device out of the box by grabbing the housing. After unpacking the device, check it for
any visible damage as a result of rough handling during the shipment. Check the delivery for
completeness. If necessary consult the transportation company, or contact WayCon directly.

MOUNTING THE SENSOR
Ultrasonic sensors may be installed in any position, as long as depositions like dust, spray mist, or
condensing humidity are avoided on the sound active membrane.
It is important to avoid structure-borne sound bridges between the sensor and it's holder.
In case several ultrasonic sensors are used in one application, it is important to leave sufficient distance
between them. Otherwise the sensors may interact which leads to false measurement values.
By using a sound deflection angle the sound beam can be redirected, at the expense of the sensor's
maximum measurement range. A plain and hard surface should be used for the defection of the sound
beam. Redirecting the sound beam with multiple sound deflection angles should be avoided.

ELECTRICAL CONNECTION
UFP-200

UFP-400 to 3500, Analog Output

Pin 1

+24 V

Pin 1

Pin 2

Teach-In

Pin 3

+24 V
0V

Pin 3

0V

Pin 4

Analog Output

Pin 4

Switch, Analog Output

Pin 5

Teach-In

UFP-400 to 3500, Switching Output
Pin 1

+24 V

Pin 2

Switching Point P2

Pin 3

0V

Pin 4

Switching Point P1

Pin 5

Teach-In

INSTALLATION GUIDE
Ultrasonic Sensors Series UFP
For further information please see the data sheet at www.waycon.biz/products/ultrasonic-sensors/

TECHNICAL DRAWING
UFP-200
range: 200 mm
output: 1 x switching point or 0...10 V

UFP-400/ 500/ 800/ 1600/ 2000:
range up to 2000 mm
output: 2 x switching points or 0...10 V or 4...20 mA

Model

X

UFP-400

89

UFP-500/800/1600/2000

96

UFP-3500:
range: 3500 mm
output: 2 x switching points or 0...10 V or 4...20 mA

SOUND CONE GEOMETRY
The exact geometry of the sound cone depends on the air-pressure, temperature, humidity and the size
of the target.
UFP-200

UFP-400

UFP-500

UFP-800

UFP-1600

UFP-2000

UFP-3500
Guaranteed detection of a target
100 x 100 mm2
Possible detection of a large
target

TEACH-IN GUIDE
Ultrasonic Sensors Series UFP
For further information please see the data sheet at www.waycon.biz/products/ultrasonic-sensors/

INTRODUCTION
Sensor with analog output:
Every sensor is delivered with the factory set-up (max. measuring range). The teach-in feature is
designed to choose a smaller range within the nominal measuring range for optimizing the resolution and
linearity. Output current, or output voltage adapt to the new range and get new characteristic curves. The
two positions P1 and P2 must be taught.
Sensor with switching output:
The teaching procedure is used to set the operation mode of the switching output and the 2 switching
points.

TEACH-IN ELEMENTS
UFP-200
: Teach-In
Line

UFP-400/ 500/ 800/
1600/ 2000/ 3500

Teach-In
Line :

EC (Echo LED) green: is on, when an echo is received (alignment LED).
P1, P2 LED yellow: LEDs P1 and P2 indicate the status of the switching outputs (UFP-200: just P1).

TEACHING THE ANALOG OUTPUT
Characteristics
P1 and P2 define the analog output slope.
P1 determines the 0 V / 4 mA position and P2 the 10V / 20 mA position.
10 V /

10 V /

0V/

0V/

Positive slope: P1 < P2

Negative slope: P2 < P1

TEACHING THE ANALOG OUTPUT
Teach-In of P1 (SP1 position)
Connect Teach In line with GND until P1 and Echo LEDs start blinking with a 2 Hz frequency (UFP-200
just yellow). and then release the contact. The sensor is now in the Teach In mode for P1: P1 LED will
now blink with 1 Hz frequency (UFP-200 with ½ Hz) and the Echo LED will go back to normal function
(alignment LED). There is a time window of 30 seconds to do the programming of P1.
Place the target at the new position P1. Contact and release Teach In line with GND: P1 is now
programmed. Sensor returns to normal function with the new value for P1.
Teach-In of P2 (SP2 position)
Connect the Teach In line with GND until the P2 and Echo LEDs start blinking with a 2 Hz frequency
(UFP just yellow, 1 Hz). First P1 and Echo LEDs will be blinking, but it is important to wait to reach P2.
The sensor is now in the Teach In mode for P2: P2 LED blinks with 1 Hz frequency now (UFP-200 just
yellow, ½ Hz). The Echo LED returns to normal function (alignment LED). There is a time window of 30
seconds to do the programming of P2.
Place target at the new position P2. Contact and release the Teach In line with GND: P2 is now
programmed. Sensor returns to normal function with the new value for P2.

TEACHING THE SWITCHING OUTPUT
Three different modes of switching outputs can be selected:
normal switching function / window function / adjustable hysteresis
All these functions will be taught with the Teach In line present in the connector. Each mode has a
different sequence using the Echo, P1 and P2 LEDs. The diagram displays the timing.

25 sec.
14 sec.

6 sec.

Teach in of switching output
SP1 at position P1. The
switching output can be either
NO (opener) or NC (closer).

Teach in of switching output
SP2 at position P2. The
switching output can be either
NO (opener) or NC (closer).

Window function/Selection of hysteresis Mode.
SP1 is switching when object is between P1 and
P2. SP2 is switching when the object is NOT
between P1 and P2.
Hysteresis adjustment of SP1 at P1.
Distance between P1 and P2 determines the
hysteresis of the switching outputs. SP1 has NO
(opener) and SP2 has NC (closer)
characteristics.

TEACH-IN GUIDE
Ultrasonic Sensors Series UFP
For further information please see the data sheet at www.waycon.biz/products/ultrasonic-sensors/

TEACHING THE SWITCHING OUTPUT
Normal Switching Function
Teach In of P1 (SP1 position)
Connect Teach In line with GND until P1 and Echo LEDs start blinking with a 2 Hz frequency and then
release the contact. The sensor is now in Teach In mode for P1: P1 LED will now blink with 1 Hz
frequency and the Echo LED will go back to normal function (alignment LED). There is a time window of
30 sec. to do the programming of P1. Place the target at the new position P1. Contact and release Teach
In line with GND: P1 is now programmed. Sensor returns into normal function with new value for P1.
Teach In of P2 (SP2 position)
Connect the Teach In line with GND until the P2 and Echo LEDs start blinking with a 2 Hz frequency. First
P1 and Echo LEDs will be blinking but it is important to wait to reach P2. The sensor is now in Teach In
mode for P2: P1 LED blinks with 1 Hz frequency now. The Echo LED returns to normal function
(alignment LED). There is a time window of 30 sec. to do the programming of P2. Place target to the new
position P2. Contact and release the Teach In line with GND: P2 is now programmed. Sensor returns into
normal function with new value for P2.
Switching output characteristics
can be selected during teach in of the set points P1 and P2. For each set point and during the teaching
procedure, when the LED is ON when contacting and releasing the teach in line to ground, the switching
output will have NO characteristics, when doing this when the LED is it OFF, the switching output will
have NC characteristics.

NO characteristics (opener)

NC characteristics (closer)

Window function / Hysteresis adjustment
Connect the teach In line with GND until P1, P2 and Echo LEDs start blinking with a 2 Hz frequency.
Before reaching the hysteresis teach in mode, the sensor will go through the P1 and P2 teaching
sequence. Keep the teach in line connected to the ground until reaching the point when all LEDs are
blinking with a 2 Hz frequency. Release the teach in line contact. The sensor is now in Teach In mode for
window function/ hysteresis adjustment: P1+P2 LEDs are blinking with a 1 Hz frequency. The Echo LED
returns to its normal function (alignment LED). There is a time window of 30 sec. to complete the
programming. Contact and release the teach In line with GND. Pay attention to P1 and P2:
If P1+P2 LEDs are OFF during the contact with the teach in line, the sensor will operate the in window
function: If there is an object between P1 and P2, SP1 will switch ON and SP2 will switch OFF. If there is
no object between P1 and P2, SP1 will switch OFF and SP2 will switch ON.
If P1+P2 LEDs are ON during contact, the sensor will operate in hysteresis mode: The switching output
SP1 will be (NO) at P1 with hysteresis P1-P2 and switching output SP2 will be (NC), also at P1 with
hysteresis P1-P2.

Window Function

Hysteresis adjustment

NOTES
Warning
These devices are not designed for critical safety or emergency shut-down purposes. Therefore they
should never be used in an application, where a malfunction of the device could cause personal injury.
Environmental Influences
Ultrasonic sensors are made for the use in atmospheric air. Environmental Influences like rain, snow, dust
or smoke have no influence on the accuracy of the measurement. However, measurements under
pressure (higher that the atmospheric pressure) are not possible with ultrasound sensors.
Strong wind or air turbulences may lead to instability in measurement values. A flow speed up to a few
m/s is unproblematic and will have no influence on the sensor's accuracy.
Target Influences
Liquids
are excellently detectable with ultra sound. A classic application for ultrasonic sensors is level
measurement. The sound beam axis however must have a maximum deviation of 3° vertically to the
liquid level (no strong waves), otherwise the reflected sound will miss the sensor.
Hot Targets
with high temperatures cause a thermal convection in the surrounding air. For this reason the sound
beam may be strongly diverted vertically to it's axis, so that the echo is weakened, or can no longer be
received at all.
For convex (cylindrical and spherical) surfaces,
every area element has a different angle to the sound cone’s axis. The reflected cone thus diverges and
the portion of the sound energy reflected to the receiver is reduced correspondingly. The maximum range
decreases with the decreasing size of the cylinder (ball).
The roughness and surface structures of the object
to be detected also determine the scanning capacities of the ultrasonic sensors. Surface structures that
are larger than the ultrasound wavelength, as well as coarse-grained bulk materials, reflect ultrasound in
a scattered manner, and are not detected optimally by the sensor under these conditions.
Hard material
reflects almost all of the impulse energy from ultrasound applications in a way that makes them very easy
to detect with ultrasound.
Soft material,
on the other hand, absorbs almost all of the impulse energy. It is thus harder to detect with ultrasound.
These materials include felt, cotton, coarse meshes, foam, etc.
Thin-walled foils
behave like soft materials. To be able to use ultrasound, the foil thickness should be at least 0.01 mm.

ACCESSORIES
UFP-400...3500

UFP-200

Cable with M12 connector, 5-pole, shielded

Cable with mating connector M12, 4 pole, shielded

K5P2M-S-M12

2 m, straight connector, IP67

K4P2M-S-M12

2 m, straight connector, IP67

K5P5M-S-M12

5 m, straight connector, IP67

K4P5M-S-M12

5 m, straight connector, IP67

K5P10M-S-M12

10 m, straight connector, IP67

K4P10M-S-M12

10 m, straight connector, IP67

K5P2M-SW-M12

2 m, angular connector, IP67

K4P2M-SW-M12 2 m, angular connector, IP67

K5P5M-SW-M12

5 m, angular connector, IP67

K4P5M-SW-M12 5 m, angular connector, IP67

K5P10M-SW-M12

10 m, angular connector, IP67

K4P10M-SW-M12 10 m, angular connector, IP67

PIN

Cable colour

1

brown

2

white

3

blue

4

black

5

grey

PIN

Cable colour

1

brown

2

white

3

blue

4

black

DECLARATION OF EC-CONFORMITY
WayCon Positionsmesstechnik GmbH
Mehlbeerenstrasse 4
82024 Taufkirchen / Germany
This is to certify that the products
Classification
Series

Ultrasonic Sensors
UFP
fulfill the current request of the following EC-directives:
EMV-directive
2004/108/CE
applied harmonized standards:
EN 61000-6-2:2005, EN 61000-6-4:2007, EN 61326-1:2006

The declaration of conformity loses its validity if the product is misused or modified without proper
authorisation.

Taufkirchen, 13.03.2013

Andreas Täger
CEO



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 8
Tagged PDF                      : Yes
Title                           : Installation Guide UFP
Author                          : Marcus Venghaus
Subject                         : Ultrasonic - Serie UFP
Keywords                        : ultrasonic, sensor, transducer, measurement, ultrasound, sound cone
Creator                         : Impress
Producer                        : OpenOffice 4.1.2
Create Date                     : 2016:12:08 08:50:44+01:00
EXIF Metadata provided by EXIF.tools

Navigation menu