VISTA 32FB Data Sheet
User Manual: Vista-32FB Data Sheet AlarmHow.net Library
Open the PDF directly: View PDF .
Page Count: 4
Designed to integrate seamlessly with CCTV, access control
and Honeywell’s full range of fire and burglary components,
the new VISTA-32FB provides the ultimate protection of life
and property. The UL Listed commercial fire and burglary
control panel supports up to eight partitions and up to
32 zones/points using hardwired, wireless and V-Plex®
addressable technologies. A diverse line of Honeywell
initiating devices, notification circuits, communication devices,
keypads, RF receivers and relays are also supported.
The VISTA-32FB has been designed to mount quickly
and easily.
• Supports addressable V-Plex access
control points using VistaKey
(One to Four doors)
• Supports eight hardwired zones,
24 V-Plex addressable points/zones,
or 32 wireless points/zones
• Can control two separate areas
(partitions) independently
• Stores up to 512 events and can
accommodate 75 user codes
• Easily programmed and maintained
with newly upgraded Compass
Downloader Software
• Automatic smoke detector sensitivity
maintenance testing
• Commercial Wireless Fire and
Burglary
• Notification Appliance Circuits (two):
– Programmable
– Individually silenceable
• Carbon monoxide (CO) zone support
(Rev 5 and higher)
• Programmable on-board auxiliary
relay
• False alarm reduction features:
– Exit error logic
– Exit delay reset
– Cross zoning
– Call waiting defeat
– Recent close report
• Supports commercial hardwired,
addressable V-Plex polling loop
and wireless zones
• Listed to UL864 9th Edition (Rev 5
and higher)
FEATURES
VISTA-32FB
COMMERCIAL PARTITIONED FIRE AND
BURGLARY ALARM CONTROL PANEL
Now UL864 9th Edition Approved
VISTA-32FB
COMMERCIAL PARTITIONED FIRE AND
BURGLARY ALARM CONTROL PANEL
• Hardwired zones
– Provides nine style B hardwired
zones
– EOLR supervised for Fire and UL
burglary installations
– Supports N.O. or N.C. sensors
– Individually assignable to one of
eight partitions
– Up to 16 two-wire smoke detectors
each on zone one and two (32 total)
• Patented addressable V-Plex polling
loop technology
– Supports up to 24 two-wire V-Plex
zones/points
– Global polling technology for
faster processing
– Supervised by panel
– Individually assignable to partitions,
notification circuit (bell) output or
aux relay
– 4,000 ft. capability without the use
of shielded cable
– Extender/Isolation bus modules
– Two-wire smoke detector
zone/group expansion module
adds two or four zones
– Eight zone – Class A and B
extender module
– Eight zone – Class B extender
module
– One zone supervised contact
monitor module
• UL Listed wireless expansion
– Supports up to 32 wireless zones/
points using 5881ENHC or
5883H Receiver
– Supervised by control for
check-in signals
– Tamper protection for transmitters
– Individually assignable up to
eight partitions
– Supports wireless smoke detectors
• Event reporting
• Local printer for access or
VISTA related event
• Up to four doors using VistaKey
V-Plex Access Control
• Stored events for one call retrieval
• Communication
– Panel operation during download
– Split/Dual Reporting
Applications
The VISTA-32FB control is well suited
for a variety of applications as an
integrated fire and burglary control.
Some of the applications supported are:
medical and professional buildings,
churches or synagogues, office
buildings, schools, strip malls,
residences and factory or warehouse
environments.
Installation
The VISTA-32FB alarm system has
been designed to mount both quickly
and easily. It meets all applicable
requirements for UL commercial fire
and burglary installations.
ADDITIONAL FEATURES
Electrical
• Primary power: 18VAC @ 72VA
ADEMCO No. 1451
• Quiescent current draw: 300mA
• Backup battery:
– 12VDC, 7AH min to 34.4AH max
– Lead acid battery (gel type)
• Alarm power: 12VDC, 1.7A max for
each notification (bell) circuit output
• Aux. standby pwr: 12VDC, 1A max
• Total power: 2.3A at 12VDC,
3.4A at 24VDC from all sources
• 24 hours with 1A standby load
Fusing
• Battery input, aux. and notification
(bell) circuit outputs are protected
using PTC circuit protectors. All
outputs are power limited.
Main Dialer
• Line seize: Double Pole
• Ringer equiv.: 0.7B
• Formats: ADEMCO Low Speed,
ADEMCO 4+2 Express, ADEMCO
High Speed, ADEMCO Contact ID,
Sescoa and Radionics
Cabinet dimensions
• 14.5" H X 12.5" W X 3" D
Environmental
• Storage temp: 14° F to 158° F
(-10° C to 70° C)
• Operating temp: 32° F to 122° F
(0° C to 50° C)
• Humidity: 85% RH
• EMI: Meets or exceeds the
following requirements:
– FCC Part 15, Class B Device
– FCC Part 68
– IEC EMC Directive
Agency Listings
• FCC Part 15, Class B; FCC Part 68
• UL864/NFPA 72, Central Station and
Remote Station (Fire)
• UL609 Local Mercantile
Premises/Mercantile Safe & Vault
• UL365 police station connected
burglar alarm
• UL610 Central Station
Burglar Alarm
• California State Fire Marshal
• FM
• CAN/ULC S304 – Central and
Monitoring Station Burglar Alarm Unit
• CAN/ULC S527 – Central Unit for
Fire Alarm Systems
• CAN/ULC S303 – Local Burglar
Alarm Unit
• CAN/ULC S525 – Audible Signal
Appliances
SPECIFICATIONS
L/VIST32FB/D
September 2009
© 2009 Honeywell International Inc.
VISTA-32FB
COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL
Auxiliary Devices
• 4204 – Relay Module,
four form C contacts
• 4204CF – Two supervised
output circuits
• 5140DLM – Supervised Dialer
• 5881ENHC – RF Receiver
• 5883H – RF Receiver
• 6160CR-2 – Red Alpha Keypad
• 6160 – Burglary Keypad
• 6220S – System printer used with
4100SM serial module
Two-Wire Smoke Detectors
Conventional
• System Sensor
• ESL
• DSC
Horn/Strobes
• System Sensor
• Wheelock
• Gentex
Manual Pull Stations
• 5140MPS-1
• 5140MPS-2
V-Plex (Addressable) Devices
• 4101SN Relay Zone Module
• 4190SN Remote Point Module
– two zones
• 4190WH
• 4193SN Two Zone Serial
Interface Module
• 4208U Loop Expansion Module
– eight zones
• 4208SNF Eight Zone/2 Class A/6
Class B Expander Module
• 4293SN One Zone Serial
Interface Module
• 4297 Isolator/Extender Module
• V-Plex VSI Isolator Module
V-Plex Smoke Detectors
• 5193SD
• 5193SDT
V-Plex Passive Infrared Detectors
• 998MX
• IS2500SN
• DT7500SN
• QUEST2260SN
V-Plex Contacts
• 4194WH
• 4939SN-WH
• 4944SN-WH
• 4959SN
V-Plex Glassbreak Detectors
• FG1625SN
AlarmNet Communicators
• 7545i-ENT – Internet/Intranet
Communicator
• 7845GSM – Digital Cellular
Communicator
• 7845i-GSM – Internet and Digital
Cellular Communicator
Access Control
• VistaKey V-Plex (addressable)
Access Control
• VistaKey-SK Starter Kit
• VistaKey-EX Expansion Kit
Commercial Wireless Devices
• 5808W3 – Photoelectronic
Smoke/Heat Detector
• 5806W3 – Photoelectric Smoke
Detector
• 5809 – Wireless Heat Detector
• 5817CB – Wireless
Commercial Transmitter
• 5869 – Hold-Up Transmitter
• 5881ENHC – RF Receiver
• 5883H – RF Receiver
COMPATIBLE DEVICES
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
Melville, NY 11747
1.800.467.5875
www.honeywell.com
ORDERING
VISTA-32FB Commercial Fire and Partitioned Burglary Alarm Platform
V32FB-9 UL864 Rev 9 Version (Rev 5 and higher)
Product specifications subject to change.