595644606_GB Electrolux Dishwasher WT65E WT38UK! Service Manual

User Manual: Electrolux Dishwasher WT65E

Open the PDF directly: View PDF PDF.
Page Count: 114 [warning: Documents this large are best viewed by clicking the View PDF Link!]

DOC. NO. 5956.446.06 P. 1 / 11 4
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
SERVICE MANUAL
CONTENTS: This document contains the instruction to change parameter settings of electronic
board by means of user interface.
EDITION: 03.2010
TANK
BOILER
3.__
TANK
BOILER
3...__
TANK
BOILER
3.__
DOC. NO. 5956.446.06 P. 2 / 11 4
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
INDICE
1 KEYBOARDS Pag. 3
1.1 HOOD TYPE Style Pag. 3
1.2 UNDERCOUNTER Style Pag. 4
2 MANUAL ACTIVATION OF DETERGENT AND RINSE AID DISPENSERS Pag. 5
2.1 Detergent Dispenser Activation Pag. 5
2.2 Rinse Aid Dispenser Activation Pag. 5
3 RINSE PUMP MANUAL ACTIVATION Pag. 5
4 DETERGENT AND RINSE AID DOSAGE Pag. 6
4.1 GEn General Parameters Pag. 6
5COUNTERS Pag. 8
5.1 Cnt Counters Pag. 8
6 TEMPERATURE SETTING Pag. 10
6.1 FAC Factory Parameters Pag. 10
7 CYCLE SETTING Pag. 12
7.1 CYCLE DIAGRAM Pag. 13
7.2 CY1 Cycle 1 Parameters Pag. 14
7.3 CY2 Cycle 2 Parameters Pag. 14
7.4 CY3 Cycle 3 Parameters Pag. 14
7.5 drn Drain/Cleaning Cycle Parameters Pag. 14
8 OTHER PARAMETERS Pag. 15
8.1 dPA Dishwashing Parameters Pag. 15
8.2 ron Read Only Parameters Pag. 16
8.3 HCP Communication and HACCP Parameters Pag. 16
8.4 CFG Configuration Parameters Pag. 17
8.5 dbG Parameters for automatic hood type dishwashers Pag. 18
9 SPECIAL FEATURES Pag. 19
9.1 RESIN REGENERATION CYCLE Pag. 19
9.2 MEDICAL LINE DISHWASHER WITH DOOR/HOOD LOCK DEVICE Pag. 19
9.3 DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION Pag. 19
9.4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER Pag. 20
10 MAIN BOARD CONFIGURATION Pag. 22
10.1 CODE -> Prog. TABLE Pag. 22
10.2 PROGRAMMING SHEETS Pag. 27
11 DEFAULT VALUES Pag. 91
12 USER INTERFACE AND MAIN BOARD CONNECTORS Pag. 94
12.1 Main malfunctions not due to the main board Pag. 94
12.2 CONNECTORS LAYOUT Pag. 94
13 ALARM MESSAGES AND TROUBLESHOOTING Pag. 107
13.1 ALARMS THAT STOP THE DISHWASHER Pag. 107
13.2 ALARMS THAT DON'T STOP THE DISHWASHER Pag. 111
13.3 ALARMS THAT DON’T STOP THE DISHWASHER FOR MODELS WITH
INCORPORATED CONTINUOUS WATER SOFTENER Pag. 113
14 LIST OF PARAMETERS FOR SUBSEQUENT VERSIONS Pag. 114
DOC. NO. 5956.446.06 P. 3 / 11 4
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
1 KEYBOARDS
1.1 HOOD TYPE Style
SETTING MODES:
To enter into one setting mode (Figure 4),(Figure 5) the appliance should be in stand-by: switch on the appli-
ance, no cycles selected. Is useful keep door open to avoid start cycle in case of not simultaneously pressure
of the two keys.
Fig.1 Detergent dispenser Manual
Activation.
Fig.2 Rinse Aid Dispenser Manual
Activation
Fig.3 Rinse Pump Manual
Activation (used to EMPTY
BOILER)
Fig.4 Enter into General
Parameters (Hold down buttons for
at least five seconds).
Fig.5 Enter into Factory
Parameters (Hold down buttons for
at least five seconds)..
Fig.6 Next Parameter Family OR
Increase Parameter Value(In setting
mode only)
Fig.7 Decrease Parameter
Value(In setting mode only)
Fig.8 Confirm Value and go to
next Parameter (In setting mode
only).
dEt dEt
rAi rAi
--- ---
GEn GEn
FAC FAC
888 888
888 888
888 888
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 4 / 11 4
1.2 UNDERCOUNTER Style
SETTING MODES:
To enter into one setting mode (Figure 12), (Figure 13) the appliance should be in stand-by: switch on the
appliance, no cycles selected. Is useful keep door open to avoid start cycle in case of not simultaneously
pressure of the two keys.
Fig.9 Detergent dispenser Manual
Activation
Fig.10 Rinse Aid Dispenser
Manual Activation
Fig.11 Rinse Pump Manual
Activation (used to EMPTY BOILER)
Fig.12 Enter into General
Parameters (Hold down buttons for
at least five seconds).
Fig.13 Enter into Factory
Parameters (Hold down buttons for
at least five seconds).
Fig.14 Next Parameter Family OR
Increase Parameter Value (in
setting mode only)
Fig.15 Decrease Parameter Value
(In setting mode only)
Fig.16 Confirm Value and go to
next Parameter (in setting mode
only).
TANK
BOILER
dEt
TANK
BOILER
rAi
TANK
BOILER
---
TANK
BOILER
GEn
TANK
BOILER
FAC
TANK
BOILER
888
TANK
BOILER
888
TANK
BOILER
888
DOC. NO. 5956.446.06 P. 5 / 11 4
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
2 MANUAL ACTIVATION OF DETERGENT AND RINSE AID
DISPENSERS
When replacing detergents may be necessary activate the dispensers to fill hoses.
2.1 Detergent Dispenser Activation
2.2 Rinse Aid Dispenser Activation
3 RINSE PUMP MANUAL ACTIVATION
Use this function to empty the boiler (if the dishwasher is not to be used for a long time, for maintenance oper-
ation: ex. before replacing main board).
Switch on the dishwasher.
Press and hold down CYCLE_2 and CYCLE INFINITE keys, after two
'beep' the detergent dispenser starts work for 20 sec.
Switch on the dishwasher.
Press and hold down CYCLE_1 and CYCLE INFINITE keys, after two
'beep' the rinse aid dispenser starts work for 40 sec.
Switch on the dishwasher.
Close the door and press and hold down DRAIN and CYCLE INFINITE
keys. A buzzer signal indicates the rinse pump activation and the dis-
play shows three blinking lines. Three beeps indicate the cycle end.
dEt
rAi
---
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 6 / 11 4
4 DETERGENT AND RINSE AID DOSAGE
In this paragraph is explained how to set the working time for the detergent and rinse aid dispensers.
For each dispenser there are two parameters: the initial time and the time during cycle execution.
4.1 General Parameters
How change the duration:
Switch OFF and switch ON the dishwasher;
Enter into the USER SETTING mode by pressing and hold down ON/OFF and CYCLE_1 keys for at least five sec-
onds the display shows  (Figure 17);
Press CYCLE_INFINITE. The display shows alternatively the symbol dIn and the duration in seconds (Figure 18) and
(Figure 19) ;
NOTE: If User Interface v.3.00 tank led is on if value correspond to factory default ( Default 1 - HOOD TYPE).
Use CYCLE_1 key to decrease the duration and CYCLE_2 key to increase (Figure 19);
After settled the duration press CYCLE_INFINITE key to store value. The display shows the next parameter (Fig-
ure 20) and the corresponding value (Figure 21);
In the same way is possible to change the other duration; when finished switch OFF and switch ON.
Sym. Parameter Description Unit Min Max Factory Default
 Initial Detergent Dosage (during filling tank) [s] 0240 90
 Initial Rinse Aid Dosage (starts when tank filled) [s] 0180 10
 Detergent Dosage During Cycle Execution (during wash
phase)
[s] 0182 (*) 8
 Rinse Aid Dosage During Cycle Execution (when refill-
ing boiler)
[s] 062 (*) 4
Fig.17 Enter into User Mode (press for 5 sec)..
Fig.18 Initial detergent
dosage.
Fig.19 Change duration.
(Tank LED indicates default).
Fig.20 Initial rinse aid
dosage
Fig.21 Change duration
Fig.22 Cycle detergent
dosage.
Fig.23 Change time
activation (Tank LED
indicates default)
Fig.24 Cycle rinse aid
dosage.
Fig.25 Change time
activation.
GEn
dIn 90 rIn 24
Val.Fabbr.
dEt 8 rAi 7
Val.Fabbr.
DOC. NO. 5956.446.06 P. 7 / 11 4
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
(*) Note for external dispensers:
•if the detergent dispenser works when WASHING PUMP is being activated; at the
same time voltage is supplied between connectors L17–L19 (main terminal box);
•if the detergent dispenser works when LOADING EV is being activated to re-fill
boiler level; at the same time voltage is supplied between connectors L17–L19
(main terminal box);
•if the rinse aid dispenser works when LOADING EV is being activated to re-fill boiler
level; at the same time voltage is supplied between connectors L18–L19 (main ter-
minal box);
•if the rinse aid dispenser works when WASHING PUMP is being activated; at the
same time voltage is supplied between connectors L18–L19 (main terminal box);
- For electrical connections refer to electric diagram -
Example
Suppose there is connected an external detergent dispenser with a probe into the tank. A typical setting
could be:
 the dispenser is not activated during filling tank.
 the dispenser is supplied during washing phase and the probe automatically dose the right
detergent amount.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 8 / 11 4
5 COUNTERS
This Parameter Family collects cycle counters and water consumption counters.
For water consumption counters a flow meter must be installed. See (calibration parameter) into 
section (8 OTHER PARAMETERS).
5.1 Counters
Sym. Parameter Description Unit Min Max Factory
Default

Cycles performed counter.
 symbol and two numbers blink consecutively. The cycle number
is obtained by joining the two numbers.
Ex.    means 10042 cycles executed.
-

Cycle counter (resettable).
This counter is similar to but is resettable by user (see 
parameter below).
-

Water Consumption (only for dishwashers with incorporated continuous
water softener).
Counts m3 of water consumption.
[m3]
Water Consumption (only for dishwashers with incorporated continu-
ous water softener).
Counts litres of water consumption.
The total consumption is given by adding [m3] and [l] values.
[l]

Water Consumption: resettable counter. [present up to software version
3.12]
Counts the litres of water and is resettable by user (see  parame-
ter below).
[l]

Reset resettable counters:  and 
To reset put 1 this parameter, switch off and then on again:  and
 will show zero. Note that  is used to count cycles for
-- message (see next parameter, ).
-

Store thousand of cycles after that -- message appears on dis-
play.
Ex. If this parameter is settled to 20,-- message appears when
 reach 20.000 cycles.
-
 Drain/Cleaning cycles performed.
Similar to  but counts Cleaning Cycles. -
 Numbers of cycles that can be made after a regeneration cycle (only for
dishwashers with non-continuous water softener) [See paragraph 9.1
RESIN REGENERATION CYCLE.].
-20

Regeneration cycle counter (only for water softener dishwasher)
[See paragraph 9.4 DISHWASHER WITH INCORPORATED CONTI-
NUOUS WATER SOFTENER].  only counts efficient regenera-
tion cycles, i.e. those carried out with salt in the special container (only
for dishwashers with incorporated continuous water softener)
-

Counter of regeneration cycles done without salt in the special con-
tainer. (only for dishwashers with incorporated continuous water sof-
tener) [See paragraph 9.4 DISHWASHER WITH INCORPORATED
CONTINUOUS WATER SOFTENER].
-
DOC. NO. 5956.446.06 P. 9 / 11 4
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
Fig.26 USER setting mode
(press for 5s).
Fig.27 Next Family Fig.28 Counters Fam.:
ENTER
Fig.29 CYCLES Fig.30 Thousand. Fig.31 Units. Fig.32 Next counter.
CYC 010 042 cYc
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 10 / 114
6 TEMPERATURE SETTING
In this paragraph is explained how to change temperature thresholds and all parameters related to boiler and
tank.
6.1  Factory Parameters
Sym. Parameter Description Unit Min Max Factory
Default
 Boiler Temperature: THRESHOLD.
When boiler temperature reaches this value, heaters switch off. [°C] 45 95 78
 Boiler Temperature HISTERESIS, (represent dead band).
Heater switch on if boiler temperature is below:  -  [°C] 210 2
 Boiler Temperature: HIGH LIMIT.
When boiler temperature reaches this value  alarm appears.
Put 0 to disable  alarm.
[°C] 098 96
 Boiler Temperature: LOW LIMIT.
During boiler warm-up, temperature must increase at least  °C
otherwise  warning appears.
Put 0 to disable  warning.
[°C] 010 1
 Boiler Filling Timeout.
If filling time is longer than , alarm appears.
Put 0 to disable  alarm.
[min] 042 5
 Boiler Temperature Adjust. [°C] 0 7 4
 Boiler Priority (enable boiler wait function)
0=disabled
1=enabled
- 0 1 1
 Booster Function
Overheat gap over Boiler Temperature Threshold [°C] 015 2
 Boiler temperature negative differential: when the dishwasher is in
standby, boiler threshold becomes:  - 
(Used to save energy during machine inactivity by keeping boiler
water at a lower temperature).
[°C] 020 0
 Tub Temperature: THRESHOLD
When tank temperature reaches this value, heater switch off. [°C] 40 85 63
 Tub Temperature: HISTERESIS, (represent dead band).
Heater switch on if tank temperature is below:  -  [°C] 230 5
 Tank Temperature: HIGH LIMIT.
When tank temperature reaches this value  alarm appears.
Put 0 to disable  alarm.
[°C] 095 75
 Tank Temperature: LOW LIMIT.
During tank warm-up, temperature must increase at least  °C
otherwise  warning appears.
Put 0 to disable  warning.
[°C] 010 1
 Tank Filling Timeout.
If filling time is longer than ,  alarm appears.
Put 0 to disable  alarm.
[min] 042 20
DOC. NO. 5956.446.06 P. 11 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
To modify thresholds do the following:
Switch OFF and switch ON the dishwasher;
Enter into the FACTORY SETTING mode by pressing and hold down ON/OFF and CYCLE_2 keys for at
least five seconds (Figure 33);
Press CYCLE INFINITE. The display shows alternatively the symbol  (Figure 34) and the corre-
sponding value (Figure 35);
Use CYCLE_1 key to decrease the value and CYCLE_2 key to increase (Figure 35);
Press CYCLE INFITE key to confirm. The display shows the next parameter (Figure 36) and the corre-
sponding value (Figure 37);
In the same way is possible to change the other parameters; when finished switch OFF and switch ON.
At the end the display will show again  and by pressing CYCLE_2 key (Fig. 41) is possible to change
cycle duration (see paragraph 7 CYCLE SETTING).
).
Fig.33 Factory setting
mode.
Fig.34 Boiler temp.
threshold
Fig.35 Change value &
Store
Fig.36 Boiler Temp
Hysteresis
Fig.37 Change value &
Store
Fig.38 Tank temp. High
limit.
Fig.39 Change value &
Store.
Fig.40 Factory setting
mode
Fig.41 Next Family Fig.42 Cycle 1 Family:
ENTER.
FAC btCbtH 76
°
2 bHi bLo 96
FAC FAC Cy1
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 12 / 114
7 CYCLE SETTING
IIn this paragraph is explained how to change cycle phases duration (see paragraph 7.1 CYCLE DIAGRAM).
Switch on the dishwasher;
Enter into the FACTORY SETTING mode: press and hold down ON/OFF and CYCLE_2 keys for at least 5
seconds (Figure 43);
Press CYCLE_2 key to select CYCLE_1 parameters.
Press CYCLE_INFINITE. The display shows alternatively the symbol  (Figure 46) and the corre-
sponding value (Figure 47);
Use CYCLE_1 key to increase the value and CYCLE_2 key to decrease (Figure 47);
Press CYCLE_INFINITE key to confirm. The display shows the next parameter (Figure 48) and the corre-
sponding value (Figure 49);
In the same way is possible to change the other parameters;.
After settled all parameters referring Cycle 1, by pressing CYCLE_2 key is possible to change the Cycle 2
parameters (Figure 50), (Figure 51) and so on.
Fig.43 Factory setting
mode.
Fig.44 Select next class. Fig.45 Cycle 1 Family:
ENTER.
Fig.46 Wash duration [min].
Fig.47 Change value &
Store
Fig.48 Wash duration [sec]. Fig.49 Wash duration
[min]..
Fig.50 Cycle 1 Parameters. Fig.51 Cycle 2 Parameters:
ENTER.
Fig.52 Wash duration [min].
Fig.53 Cycle 2 Parameters:
next Family
Fig.54 Cycle 3 Parameters:
ENTER
Fig.55 Wash duration [min].
FAC FAC Cy1 Ln1
0 5h1 35
Cy1 Cy2 Ln2
Cy2 Cy3 Ln3
DOC. NO. 5956.446.06 P. 13 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
7.1 CYCLE DIAGRAM
CYCLE TYME
LEGENDA:  = drain
 = wash  = rinse pause
 = pre rinse  = final pause
 = rrinse  = detergent
 = cold rinse  = rinse aid
IPA Ln Sh
PA
Pr
ri
cr
FP
dr
rPA
dEt
rAi
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 14 / 114
7.2  Cycle 1 Parameters
7.3  Cycle 2 Parameters
7.4  Cycle 3 Parameters
7.5  Drain/Cleaning Cycle Parameters
Sym. Parameter Description Unit Min Max Factory
Default
 Wash Phase Long [min] 020 0
 Wash Phase Short [s] 160 35
 Pause [s] 020 4
 Pre-rinse Duration [s] 030 0
 Rinse Phase Duration [s] 10 45 16
 Cold Rinse Phase Duration [s] 050 0
 Drain [s] 040 16
 Final Pause at End of Cycle [s] 060 0
Sym. Parameter Description Unit Min Max Factory
Default
 Wash Phase Long [min] 020 0
 Wash Phase Short [s] 160 45
 Pause [s] 020 4
 Pre-rinse Duration [s] 030 0
 Rinse Phase Duration [s] 10 45 16
 Cold Rinse Phase Duration [s] 050 0
 Drain [s] 040 16
 Final Pause at End of Cycle [s] 060 0
Sym. Parameter Description Unit Min Max Factory
Default
 Wash Phase Long [min] 020 1
 Wash Phase Short [s] 160 40
 Pause [s] 020 4
 Pre-rinse Duration [s] 030 0
 Rinse Phase Duration [s] 10 45 16
 Cold Rinse Phase Duration [s] 050 0
 Drain [s] 040 16
 Final Pause at End of Cycle [s] 060 0
 Boiler Temperature Threshold: only for Cycle 3.
This parameter allows having a different rinsing temperature for
the third cycle. Only values above 45°C are allowed.
[°C] 095 0
Sym. Parameter Description Unit Min Max Factory
Default
 Initial Drain Phase Duration [s] 0240 40
 Final Drain Phase Duration [s] 0240 60
 Drain without cleaning cycle - 0 1 0
DOC. NO. 5956.446.06 P. 15 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
8 OTHER PARAMETERS
8.1  Dishwashing Parameters
Note: ,, ,  parameters emulates a two levels pressure switch, keep in mind that value
doesn’t correspond to a physical quantity.
Sym. Parameter Description Unit Min Max Factory
Default
 Initial Pause before start washing (for ALL cycles) [s] 010 0
 Delay for the 2nd wash pump (PW only) [s] 010 3
 Active a drain phase at the end of washing phase. [s] 040 0
 Duration of pause after rinse cycle (valid for dishwashers with
door/hood lock device) [See par. 9.2 MEDICAL LINE
DISHWASHER WITH DOOR/HOOD LOCK DEVICE].
[s] 060 0
 Celsius/Fahrenheit selection
0 = Celsius
1 = Fahrenheit
- 0 1 0

Rinse Temperature Display.
Enable rinse temperature probe (if installed).
0 = during rinse phase the display shows boiler temperature;
1 = during rinse phase the display shows rinse temperature;
- 0 1 0
 Pulse Per Litre.
This parameter must be settled in according to flow meter
installed [present up to software version 3.12].
[p/l] 0255 0

Number of wash cycles performable without detergent (only for
dishwashers with external detergent level sensor – par. 9.3
DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION)
[]
- 0 5 5

Pressure sensor threshold 1 [present up to software version 2.11].
- 0 255 140

Pressure sensor histeresis 1 [present up to software version 2.11].
- 0 255 50

Pressure sensor threshold 2 [present up to software version 2.11].
- 0 255 140

Pressure sensor histeresis 2 [present up to software version 2.11].
- 0 255 50
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 16 / 114
8.2  Read Only Parameters
8.3  Communication and HACCP Parameters
Sym. Parameter Description Unit Min Max Factory
Default
 Main Board Firmware Release - - - -
 Water softener board software version. (only for dishwashers with
incorporated continuous water softener). - - - -

Active column: indicates through which of the two continuous
water softener columns boiler filling is being carried out: 0 = col-
umn A and 1 = column B (only for dishwashers with incorporated
continuous water softener).
- - - -
--
When
--
message appears, the parameter value becomes 3.
After maintenance, to clear -- message, insert 0. - - - -

When   alarm appears, the machine is frozen and this
parameter is 3.
After maintenance (see alarm codes document), insert 0 to ena-
ble the machine.
- - - -

This alarm appears in case of malfunctioning in the continuous
water softener. To facilitate fault-finding, see par. 13.3 ALARMS
THAT DON’T STOP THE DISHWASHER FOR MODELS WITH
INCORPORATED CONTINUOUS WATER SOFTENER.
- - - -
Sym. Parameter Description Unit Min Max Factory
Default

Serial Device
0 = 8N1
1 = PC connection (DAAS 8E1)
7 = HACCP network (ECAP 8E1+LK485) (LK485 board is nec-
essary)
9 = Dishwashers with incorporated continuous water softener
11 = Machines with incorporated continuous water softener that
communicate with LK485 board
16 = HACCP printer (8N1)
32 = MODEM GSM (DAAS 8N1)
33 = MODEM GSM (DAAS 8E1)
48 = Hyper Terminal (8N1)
- 0 63 1

Address.
This parameter specifies the address of the appliance into the
‘HACCP_network’.
Works only if ‘HACCP network’ is selected (see above parameter).
- 0 255 1
 Print parameter table. - 0 1 1
 HACCP ‘Basic’ (printer)
Boiler temperature: high limit. [°C] 45 95 90
 HACCP ‘Basic’ (printer)
Boiler temperature: gap below high limit. [°C] 020 10
 HACCP ‘Basic’ (printer)
Tank temperature: high limit. [°C] 35 75 68
 HACCP ‘Basic’ (printer)
Tank temperature: gap below high limit. [°C] 020 10
DOC. NO. 5956.446.06 P. 17 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
8.4  Configuration Parameters
Sym. Parameter Description Unit Min Max Factory
Default

Dishwasher Model:
0 = HOOD TYPE & UNDERCOUNTER
1 = POT WASHER
2 = AUTOMATIC POT WASHER
3 = MEDICAL LINE DISHWASHER WITH LOCK DOOR/HOOD
DEVICE
- 0 3 0

Boiler type:
0 = ATMOSPHERIC BOILER
1 = PRESSURE BOILER
2 = EXTERNAL BOILER
- 0 2 0

Door type:
0 = AUTOMATIC HOOD
1 = MANUAL HOOD
2 = FRONT LOADING
3 = POT WASHER
0 3 1

Default model (see Default tables):
1 = HOOD TYPE
2 = POT WASHER
3 = UNDERCOUNTER
- 0 3 -

Solid State Relay (TRIAC).
0 = not enabled;
1 = SOFT START enabled;
3 = SLOW SOFT START enabled
(works only on boards with Solid State Relay).
- 0 3 0

Boiler/Tank heating swap:
0 = boiler heaters and tank heater can work simultaneously;
1 = swap enabled: tank heating starts only boiler temperature is
reached;
(Note: disabling this function changes the global electrical power
of appliance; before enabling this function check available power,
supply cable section, fuses in according to User Manual).
- 0 1 1

Tank Filling Mode
Enable filling tank by means of rinsing cycles.
Ex:  = 75 means that boiler water is heated at 75°C, then
follows a rinse phase and so on until tank is full.
If  = 0 the tank is filled by solenoid valve in the traditional
way (On machines with incorporated continuous water softener,
even if  is set to 0, filling occurs through subsequent rinses).
[°C] 085 75
 Detergent Level Switches
0 = level switches not enabled;
1 = enable detergent level switches;
- 0 1 0

USER INTERFACE MODEL
8 = ACTIVE function disabled (up to version 3.11 [up to serial
nr. 42100099] set to 0)
9 = hood type, under counter (up to version 3.11 [up to serial
nr. 42100099] set to 1)
13 = LS5 with atmospheric boiler(up to version 3.11 [up to
serial nr. 42100099] set to 5)
15 = LS5 with pressure boiler (user interface without display); (up
to version 3.11 [up to serial nr. 42100099] set to 7)
24 = LS5 with atmospheric boiler (From Ser. Nr.: 821).
See parameter (family ) to check the software ver-
sion installed in the board.
- 0 15 9
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 18 / 114
8.5  Parameters for automatic hood type dishwashers
 Enable “regeneration cycle” key (only for dishwashers with non-
continuous water softener) [See paragraph 9.1 RESIN REGENE-
RATION CYCLE].
- 0 1 0

ALARMS ENABLE
0 = alarms disabled (to disable also warnings see  and
);
1 = alarms enabled;
If this function is disabled, faults can be detected so display do
not shows any alarm code.
- 0 1 1
 Air gap with float level sensor normally closed (the level sensor is
closed when the boiler is empty). E.g. the boiler level sensor for
machines with incorporated continuous water softener.
- 0 1 0

Forced start of a resin regeneration cycle (only for dishwashers
with incorporated continuous water softener). [See paragraph 9.4
DISHWASHER WITH INCORPORATED CONTINUOUS WATER
SOFTENER].
- 0 2 0

Max. rinse water hardness (only for dishwashers with incorpo-
rated continuous water softener). After modifying, disconnect and
reconnect the machine's main power supply by means of the
main switch. [See paragraph 9.4 DISHWASHER WITH INCOR-
PORATED CONTINUOUS WATER SOFTENER].
°fH 414 10
 Boiler heating control.
Defines the max. permissible temperature difference during boiler
heating in a time interval of 2 minutes and 30 seconds.
°C 25 80 50
Sym. Parameter Description Unit Min Max Factory
Default
 DELAY_K1
Time (during hood lifting) within which S3” must return to the rest
position.
0.1 s 0.0 s. 20.0 s 15
 HOOD_TOUT
TIMEOUT – max. time allowed for complete hood opening/clos-
ing.
0.1 s 0.0 s 20.0 s 200

DELAY_K1_S3
During hood lowering, firstly S3” must cut in and then after a time
 .the bottom limit switch S3.
0.1 s 0.0 s. 20.0 s 15
 DELAY_K
Time within which K and K’ must be both closed or both open. 0.1 s 0.0 s. 20.0 s 10
 DELAY_S3
Time during hood lifting within which the bottom limit switch must
return to the rest position..
0.1 s 0.0 s. 20.0 s 20
 DELAY_S5
Time during hood lowering within which the top limit switch must
return to the rest position.
0.1 s 0.0 s. 20.0 s 20
 Displays the last alarm code relative to automatic hood type dish-
washers. - - - 0
 Parameter only valid for hood type models.
Hood lifting motor absorption threshold.
(50 units correspond to a current of approx. 1 ampere).
- 0 250 100
DOC. NO. 5956.446.06 P. 19 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
9 SPECIAL FEATURES
9.1 RESIN REGENERATION CYCLE
The regeneration cycle is activated by pressing the button shown in the figure, for at least 5 seconds.
For this key to be enabled parameter (in family ) must be set to 1.
At this point you can enter the number of wash cycles that can be performed after each regeneration: param-
eter  in the counters family . If  is set to zero the counter is disabled, otherwise after the pre-
set number of cycles the message  is displayed to confirm that regeneration is possible (this is an
information-only message with no effect on operation of the appliance, so you can continue to use the dish-
washer). The message is cleared when the regeneration cycle is terminated.
The number of regeneration cycles performed can be checked by consulting the parameter  in the 
family of counters.
When there are just 15 cycles remaining before the next regeneration cycle, at the end of the wash cycle the
display shows the message  followed by , at the end of the next wash cycle the display shows 
and , and so forth, i.e. the display informs the user of the number of wash cycles still available before resin
regeneration is required.
Before starting the regeneration cycle remove the siphon spillway.
WARNING:
If the regeneration cycle is accidentally started, it can be switched off by pressing the button shown in
the figure, for at least 5 seconds
The hardness of the water exiting the softener can vary between 3°fH - 10 °fH / 1.7 °dH - 5.6 °dH / 2.1 °cH - 7
°cH.
9.2 MEDICAL LINE DISHWASHER WITH DOOR/HOOD LOCK DEVICE
The medical line dishwasher with door/hood lock device has a device that prevents door/hood opening for the
entire duration of the work cycle.
For the door/hood lock to be active, the parameter (in the  family) must be set to .
The dishwasher door/hood is locked at the start of a wash cycle and is released at the end of the final pause
after rinse. The wash compartment can be accessed by stopping the work cycle in progress, as the locking
device is thus disabled. .
A pause at the end of rinse can be set by means of the parameter  (in the  family). This parameter
is common to all 3 wash cycles. The rinse water temperature is displayed during this pause. Another final
pause in the cycle can be set by setting the parameters , , . During the final pause the display
shows the time remaining for completion of the cycle. The door/hood lock device will be deactivated at the end
of the final pause (, , ).
For correct performance of the wash cycle the pause at the end of rinse and the final pause must assume the
default values (see Prog 032 – 034 - 035).
9.3 DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION
By setting the parameter (in the  family) to 1, management of the level sensors located inside the
external detergent and rinse aid tanks is enabled. During the rinse phase, when the rinse aid inside the tank
has finished, the message appears on the display.
TANK
BOILER
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 20 / 114
When the detergent inside the tank is finished, the message   is displayed and after a number of
wash cycles equal to  (in the  family) the dishwasher inhibits the activation of other wash cycles.
Therefore the detergent level in the tank must be restored.
9.4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER
Dishwashers with incorporated continuous water softener have a continuous softener in the water circuit. By
means of special resins, this device removes the calcareous substances from the feed water, supplying decal-
cified water for washing.
To activate the continuous water softener, set the parameter  (in the  family) to the value or the
value  if the water softener board is connected to the LK485 board.
For the continuous softener to work properly the resins must be regenerated periodically with a frequency
depending on the hardness of the inlet water, the number of wash cycles carried out and the max. hardness
set with the parameter  (in the  family).
Unlike conventional water softeners, this continuous softener does not require machine stops for regenerating
the resins.
To regenerate the resins it is necessary to put coarse salt in the special container located in the dishwasher.
In particular, the salt container must be filled when the dishwasher is used for the first time and whenever the
messages  or  are displayed at the start or end of a wash cycle. The salt container holds
up to 1.5 kg of salt
WARNING:
Use only coarse salt with a NaCl purity grade of 99.8 %. The use of salt with a lower purity grade may
cause the sale container filter to clog and the water softener to malfunction.
WARNING:
The messages  or may appear for several wash cycles even after topping-up the
salt, as the salt must circulate in the entire system. Correct operation of the dishwasher is not, how-
ever, affected
The number of regeneration cycles performed can be checked by consulting the parameter  in the 
family of counters.
 only counts regeneration cycles carried out with the salt container adequately filled; there is another
counter, (in the  family) that indicates the number of regeneration cycles done without salt.
If the parameter SrU is set to the value10, according to the factory setting, the water softener outlet water
hardness can vary between 3°fH - 10 °fH/ 1.7 °dH - 5.6 °dH / 2.1 °cH - 7 ° cH.
AUTONOMY OF A COLUMN OF RESINS ACCORDING TO THE CHANGE IN INLET WATER HARDNESS,
WITH OUTLET WATER HARDNESS OF 10 °fH / 5.6 °dH /7 °cH ( according to the factory
setting).
Maximum outlet water hardness can be modified by setting the  value. The outlet water hardness can be
modified from the value of 4° fH to 14° fH.
°fH °dH °cH Number of cycles
15 8,4 10,5 14
20 11,2 14 10
25 14 17,5 7
30 16,8 21,1 6
35 19,6 24,6 5
40 22,4 28,1 4
DOC. NO. 5956.446.06 P. 21 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
NB: To save the new water hardness value, in addition to the normal parameter modification and saving oper-
ations it is necessary to disconnect and reconnect the machine's main power supply by means of the main
switch on the external board.
Water softener operation can be checked by forcing the regeneration of resins, without waiting for the outlet
water hardness to reach the set max. value ( ).
To do this, wait for the water softener to finish previous resin washing or regeneration operations and set the
parameter ( family) to for regenerating column A or to for regenerating column B.
Switch the machine off and on again so that it carries out complete regeneration of the set column. If previous
resin washing or regeneration operations were not completed, the manual request for regeneration is not car-
ried out.
It is possible to check which column is being used for boiler filling by querying the parameter  (
family): if  = 0 column “A” is used, if  =1 column “B” is used.
The number of litres used by the machine can be checked by querying the parameters  (m3 ) and
(litres). To calculate the total number of litres used by the machine, add the  and values.
NB: In machines with incorporated continuous water softener, tank filling cannot be carried out through over-
flowing () but only by means of successive rinse cycles (). Therefore the  parameter
must be set to 
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 22 / 114
10 MAIN BOARD CONFIGURATION
When receiving an electronic board (spare part) may be necessary to configure it in according to the machine
where has to be replaced
1. With the machine CODE enter into the following table and read the corresponding Prog. number
2. Follow the instructions reported into the corresponding Prog.XXX sheet (next pages).
3. With the machine CODE find the Layout number in Par. 12.2 CONNECTORS LAYOUT.
10.1 CODE -> Prog. TABLE
MODEL CODE Prog. Layout
WT4
400007
Up to Ser.: 806 021 11
From Ser.: 807 065 11
WT4B
400008
Up to Ser.: 806 020 16
From Ser.: 807 064 16
WT4D
400009
Up to Ser.: 806 021 11
From Ser.: 807 065 11
WT4DB
400015
Up to Ser.: 806 020 16
From Ser.: 807 064 16
WT46 400016 020 16
WT4G 400017 022 8
WT4DG400018 022 8
WT4WS1
400019
Up to Ser.: 806 024 21
From Ser.: 807 066 21
WT4BWS
400027
Up to Ser.: 806 012 17
From Ser.: 807 063 17
WT4DWS1
400028
Up to Ser.: 806 024 21
From Ser.: 807 066 21
WT4BDWS
400029
Up to Ser.: 806 012 17
From Ser.: 807 063 17
WT4D60
400042
Up to Ser.: 806 021 11
From Ser.: 807 065 11
WT4DDG
400043
Up to Ser.: 806 036 11
From Ser.: 807 067 11
LS5/1
400100
Up to Ser.: 806 021 11
From Ser.: 807 065 11
LS5/1 DP
400102
Up to Ser.: 806 021 11
From Ser.: 807 065 11
LS5/1WS
400103
Up to Ser.: 806 024 21
From Ser.: 807 066 21
LS5/1WSDP
400110
Up to Ser.: 806 024 21
From Ser.: 807 066 21
LS5/3
400112
Up to Ser.: 806 020 16
From Ser.: 807 064 16
LS5/3 DP
400113
Up to Ser.: 806 020 16
From Ser.: 807 064 16
LS5/3WS
400114
Up to Ser.: 806 012 17
From Ser.: 807 063 17
LS5/3WSDP
400115
Up to Ser.: 806 012 17
From Ser.: 807 063 17
LS5/3WSDPD
400117
Up to Ser.: 806 012 17
From Ser.: 807 063 17
LB5G 400118 022 8
LB5GDP 400119 022 8
LS5/1DP60
400124
Up to Ser.: 806 021 11
From Ser.: 807 065 11
LS5/1DPAUS
400125
Up to Ser.: 806 036 11
From Ser.: 807 067 11
LS5/1DPCS
400126
Up to Ser.: 806 036 11
From Ser.: 807 067 11
LS6EP 502003 013 16
LS6EP/DD 502004 013 16
LS6EA/DD 502005 011 8
LS6EA/DD/DP 502006 011 8
WT38TDE 502007 032 10
WT38/M50 502008 015 9
LS6EADPWS 502014 044 8
LS6EADPWSG 502015 044 8
WT38WS 502016 044 8
WT38WSG 502017 044 8
WT38MEDWS 502018 045 8
WT38PM50 502019 039 19
WT37LEV/9 502020 051 18
LS6EADPDWS 502022 044 8
WT38DWS 502023 044 8
LS6SANA 502024 053 10
MODEL CODE Prog. Layout
DOC. NO. 5956.446.06 P. 23 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT38M50/4 502029 015 9
LS6EA/UK 502030 011 8
LS6EA/UKDP 502031 011 8
LS6EA/60 502041 011 8
WT 38DD 502110 011 8
WT 37 502111 011 8
WT 38 502112 011 8
WT 37/4.5 502117 011 8
WT 38/4.5 502118 011 8
WT 37/UK 502122 046 8
WT38C 502125 033 18
WT38C60 502126 033 18
WT38CUK 502127 033 18
WT38/4.5NW 502129 011 8
WT 38/UK 502217 011 8
WT37J60 502218 046 8
WT37J50 502219 046 8
LS6AH240U 502312 027 9
WT30H208U 502313 031 9
WT30H240U 502314 031 9
WT30H208DU 502315 027 9
WT30H240DU 502316 027 9
WT30H208RU 502317 031 9
WT30H240RU 502318 031 9
LS6H208DU 502319 027 9
LS6AH208U 502320 027 9
WT 38/60 502321 011 8
WT 38/M60 502322 015 9
WT 38MED 502323 014 8
LS6H240DU 502325 027 9
LS6H208RU 502326 027 9
LS6H240RU 502327 027 9
WT30M208U 502328 034 10
WT30M240U 502329 034 10
WT30M208DU 502339 034 10
WT30M240DU 502341 034 10
WT30M208RU 502342 034 10
WT30M240RU 502343 034 10
WT30C208DU 502344 038 9
WT30C240DU 502345 038 9
WT38PM60 502346 039 19
WT38M60/4 502347 015 9
WT30H208WS 502348 056 9
WT30H240WS 502349 056 9
WT30H208DN 502352 068 9
WT30H240DN 502353 068 9
WT38WL 502514 055 8
LS6EA 502520 011 8
LS6EA/DP 502521 011 8
LS6EAH 502523 011 8
LS6MCD 502524 033 18
LU7PDP 503020 040 24
LU7ADP 503021 041 22
LU7ADPWS 503022 061 22
WTU40PDP 503023 040 24
MODEL CODE Prog. Layout
WTU40ADP 503024 069 22
WTU40ADPWS 503025 070 22
WTU40ADPD 503026 069 22
LS 10 504100 002 1
LS14EA 504101 001 4
LS 10 UK DP 504102 002 1
ET12E 504104 003 1
LS 10/60Hz 504105 002 1
LS 10 CW 504107 002 1
LS 10 INS 504108 002 1
HT 1200 ins DEK 504109 001 1
LS14EA/INS 504110 001 4
LS 10 N 504111 002 1
LS 10 DP 504114 002 1
LS 10 HD 504115 008 1
LS14EA/AU 504116 004 15
LS14EA/60 504117 001 4
LS 10 UK1 504118 002 1
LS 10 UK3 504119 002 1
LS 12 INS 504120 001 1
LS 12 504121 001 1
LS 12 DP 504122 001 1
LS 12 60Hz 504125 001 1
LS 12 CW 504128 001 1
HT 1200 DEK 504129 001 1
LS14EA/ASIA 504131 009 4
LS14EA/G 504133 001 4
WT 60 DP 504134 001 1
WT 60 504135 001 1
WT 60 CW 504136 001 1
WT 60 UK DP CW
INS 504137 001 1
WT 60 INS 504138 001 1
WT 60 CW INS 504139 001 1
WT 60 AU CW 504140 004 14
WT 60 AU N 504141 004 14
LS10EA 504142 002 4
WT 60/60HZ 504145 001 1
WT 60/60HZ CW 504146 001 1
WT 60 N 504151 001 1
WT 60 N INS 504152 001 1
LS 12 HD 504153 007 1
LS14EA/DD 504155 001 4
WT65E 504156 001 1
WT65EB 504157 001 4
WT65EI 504158 001 1
WT 60 AU DP 504159 004 14
LS 12 UK/3 CW 504161 001 1
WT 60 UK CW 504162 001
LS 12 AU 504163 004 14
LS 12 UK DP CW 504164 001 1
ECOTEMP 12 SW 504165 001 1
WT65EBI 504166 001 4
WT65EBIA 504167 004 15
WT65EIA 504168 004 15
MODEL CODE Prog. Layout
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 24 / 114
WT65E60 504169 001 1
WT65EB60 504170 001 4
WT 60 U/400 504171 006
WT 60 U/440 504172 006
WT65EBIDG 504173 001 4
WT65EBASIA 504174 009 4
WT65EIM50 504175 006 2
WT65EIM60 504176 006 2
WT 60 MX 220/60 504177 001 1
LS 12 CW INS 504178 001 1
LS14ADP/G 504179 001 4
WT65MED 504180 010 4
WT65EJ50 504183 001 1
WT65EJ60 504186 001 1
LS14AH240U 504187 028 3
WT65H208U 504188 028 3
WT65H240U 504189 028 3
LS 12 ASIACW 504190 009 1
WT 60 ASIACW 504191 009 1
LS 12 ASIANB 504192 009
WT60ASIANB 504193 009
LS14H208DU 504194 028 3
LS14AH208U 504195 028 3
LS14H240DU 504196 028 3
LS14H208RU 504197 028 3
LS14H240RU 504198 028 3
WT65H208DU 504199 028 3
WT65H240DU 504200 028 3
WT65H208RU 504201 028 3
WT65H240RU 504202 028 3
WT65M208U 504203 035 12
WT65M240U 504204 035 12
WT65M208DU 504205 035 12
WT65M240DU 504206 035 12
WT65M208RU 504207 035 12
WT65M240RU 504208 035 12
LS14EAWS 504209 042 4
LS14ADPWSG 504210 042 4
LS14EAIWS 504211 042 4
WT65EBWS 504212 042 4
WT65BIDWSG 504213 042 4
WT65EBIWS 504214 042 4
WT65MEDWS 504215 043 4
WT65H208WS 504216 057 3
WT65H240WS 504217 057 3
ET12EWS 504218 058 4
WT65ROW 504219 052 6
LS14ROW 504220 052 6
LS14SANA 504221 054 12
WT65EID 504222 001 4
WT65EBIWSD 504223 042 4
LS14ROW60 504224 052 6
WT65ROW60 504225 052 6
LS9P 505022 019 13
LS9P DD 505033 019 13
MODEL CODE Prog. Layout
LS9A UK 505034 018 20
LS9P60 505035 019 13
WT55P 505038 019 13
WT55P6 505039 019 13
LS9ADG1 505041 018 23
WT55ADG1 505042 018 23
LS9PAUS 505043 019 13
WT55PM50 505044 019 13
WT55PM60 505045 019 13
PW1SMG 506007 005 3
PW1MG 506010 005 3
PPW1 M UK 506011 005 3
PPW1 60 Hz 506012 005 7
PW1MHG 506013 005 3
PW2MG 506014 005 3
PPW2 M UK 506015 005 3
PPW2 60 Hz 506016 005 7
PPW2 V 506017 005
WT830 M 506018 005 3
WT830 M UK 506019 005 3
WT830M60G 506020 005 3
WT850 M 506022 005 3
WT850 M UK 506023 005 3
WT850M60G 506024 005 3
WT850 V 506025 005
WT830MHG 506026 005 3
WT830M208U 506029 037 3
WT830M240U 506030 037 3
WT830H208U 506031 037 3
WT830H240U 506032 037 3
WT850M208U 506033 037 3
WT850M240U 506034 037 3
PW1M208U 506035 037 3
PW1M240U 506036 037 3
PW1MH208U 506037 037 3
PW1MH240U 506038 037 3
PW2M208U 506039 037 3
PW2M240U 506042 037 3
PW2SMG 506044 005 3
ET830M 506045 005 3
ET830MH 506046 005 3
ET850M 506047 005 3
PW1EAG 506207 017 5
PW2EAG 506212 017 5
WT830EA 506215 017 5
WT850EA 506216 017 5
WT830EAG 506217 017 5
WT850EAG 506218 017 5
FL5 690004 020 16
FL5DP 690005 020 16
LV5
690006
Up to Ser.: 806 020 16
From Ser.: 807 064 16
MODEL CODE Prog. Layout
DOC. NO. 5956.446.06 P. 25 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LV5DP
690007
Up to Ser.: 806 020 16
From Ser.: 807 064 16
LV5/3WSDP
690008
Up to Ser.: 806 012 17
From Ser.: 807 063 17
FL5/3WSDP 690009 012 17
UC5/1DP 690010 021 11
UC5/1WSDP 690011 024 21
LD5DP 690013 020 16
LD5 690014 020 16
UC5/1DITO 690017 021 11
UC5/1DPDITO 690018 021 11
FL5DDG 690027 067 11
FL 620EP 698003 013 16
ET5EDG 698004 023 8
LV6EP 698006 013 16
H3300 698007 029 8
H2500 698008 019 13
H3500 698009 001 4
ET5EDCW 698010 016 8
LV6EADPWS 698011 048 8
HT1200WS 698012 042 4
HT1200IWS 698013 042 4
FL620ADPWS 698014 048 8
H1310SANA 698016 030 8
H1510SANA 698017 010 4
LV1200IWS 698018 042 4
ET7ADP 698019 047 22
HT900P 698022 019 13
LV900P 698023 019 13
LD900 698024 019 13
FL620EAG 698026 011 8
FL620DPWSG 698027 044 8
HT900ADG1 698028 018 23
HT1200BIDG 698029 001 4
LU700PDP 698033 040 24
LU700ADP 698034 047 22
LU700ADPWS 698037 062 22
HT1200BIDWG 698038 042 4
PW100MG 698039 005 3
PW100 M 698040 005 3
PW200 M 698041 005 3
PW200 V 698042 005 3
PW100MHG 698043 005 3
LV100M 698044 005 3
LV200M 698045 005 3
PW200MG 698046 005 3
HT 1200 698050 001 4
HT 1000 698051 002 4
HT 1000 INS 698052 002 1
HT 1200 INS 698053 001 4
HT 1200 DP 698055 001 1
ET12EIG 698056 026 3
ET12EI 698057 025 4
MODEL CODE Prog. Layout
LV1000 698059 002 4
LV1200INS 698060 001 4
ET12EICWG 698061 001 3
ET12EICW 698062 025 3
ET12EIWS 698063 059 4
ET12EIF 698065 050 4
FL 620EA 698070 046 8
FL 620EADP 698071 046 8
ET5E 698076 016 8
ET5ED 698077 016 8
FL 620EP/DD 698078 013 16
FL 620EA/DD 698079 046 8
FL 620EADP/DD 698080 046 8
LV6EA 698081 046 8
LV6EADP 698082 046 8
ET5EDWS 698084 060 8
ET5EDF 698090 049 8
LS10 INS DP S36220 002
LS 10 INS S37858 002
LS 10 S39968 002
LS 10/fiera S42549 002
LS 10 INS S43062 002
LS 10 S43327 002
HT 1000 S475CH 002
LS 10 CW S47APN 002
LS 10 CW S47CF5 002
LS 10 CW S47DU4 002
LS 10 CW S47DU7 002
LS 10 CW S47DUA 002
LS 10 CW S47DUF 002
LS 10 CW S47E17 002
LS 10 CW S47E2C 002
LS 10 CW S47E2H 002
LS 10 CW S47E2M 002
LS 10 CW S47E2R 002
LS 10 UK1 S47E50 002
LS 10 CW S47E6M 002
HT1200 S46002 001
WT 60 CW INS S46880 001
HT 1000 S4734M 002
WT 60/9 S47539 001
WT 60/9 S4756O 001
WT 60/9 S4756P 001
WT60 INS S475GJ 001
WT60 INS S475GY 001
WT 60 CW S476HA 001
LS 12 HD S4775E 007
HT1200 S4777U 001
LS 12 CW INS S477BM 001
WT 60 AU CW S477JR 004
WT 60 INS S477M1 001
WT 60 INS S477M1 001
WT 60 N INS S477MB 001
WT 60/60HZ DP S477QB 001
LS 12 CW INS S477V7 001
MODEL CODE Prog. Layout
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 26 / 114
WARNING:
When modifying parameter , all the parame-
ters (except those belonging to the  family)
assume the default values according to the
tables in section 11 DEFAULT VALUES. The
parameters of the  family are not modified.
WT 60 DP S47811 001
WT 60/9 S4781D 001
WT 60/60HZ DP S4781I 001
WT 60/9 INS S4786P 001
WT 60 U/230 S478KF 006
LS 12 CW INS S478LV 001
WT 60 CW INS S478SP 001
LS 12 CW INS S479VE 001
WT 60 S479Z3 001
WT 60 S479Z9 001
WT 60 AU CW S47AP80 004
LS 12 CW S47APP 001
HT 1200 S47B9I 001
LS 12 UK/3 CW S47BJI 001
LS 12 CW S47C1Z 001
WT 60 CW S47C6B 001
LS 12 CW S47CCS 001
WT 60 S47CCY 001
WT 60 CW S47CEA 001
WT 60/9 S47CEH 001
WT 60/9 S47CEI 001
WT 60 S47CKD 001
LS 12 CW D04713 001
LS 12 CW S34369 001
WT 60 giappone S34377 001
WT 60 giappone S34378 001
WT 60 giappone S35178 001
WT 60 giappone S35179 001
LS 12 CW S35246 001
HT1200 S35330 001
WT 60 giappone S36384 001
WT 60 giappone S36385 001
LS 12 CW S36846 001
LS 12 CW S36847 001
HT1200 S39964 001
HT1200 S40472 001
ECOTEMP 12 S40785 003
WT 60/9 INS S41170 001
HT1200 S41185 001
LS 12 INS S42032 001
WT 60/60HZ S42170 001
LS 12/fiera S42550 001
WT 60/60HZ S42617 001
WT 60 N S43119 001
LS12 CW S43488 001
LS 12 INS S43563 001
LS 12 DP CW S43734 001
LS 12 CW S43806 001
LS 12 CW S43830 001
WT 60 CW INS S44421 001
LS6EA S477BL 011
WT 37 S4784U 011
LS6EA S4787B 011
FL 620EA S478BN 011
WT830 MH S46881 005
MODEL CODE Prog. Layout
PPW1 M S4758V 005
WT830 MH S476YZ 005
PPW1 MH S477IT 005
WT830 M S479QS 005
PPW1 M UK S47BKQ 005
WT 60 CW INS S47CPB 001
WT 60 CW INS S47CQS 001
ECOTEMP 12 SW S47CVG 001
ECOTEMP 12 SW S47CVH 001
WT 60 CW INS S47D9Y 001
WT 60 S47DCA 001
LS 12 CW S47DE0 001
LS 12 CW S47DMM 001
WT 60 S47DSK 001
WT 60 S47DWC 001
WT 60 S47DWD 001
PPW1 MH S47C37 005
S499BK 064 16
MODEL CODE Prog. Layout
DOC. NO. 5956.446.06 P. 27 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
10.2 PROGRAMMING SHEETS
LS12 - LS14 / WT60 - 65 PROG 001
1. Switch OFF and then switch ON the machine..
2.  Entrare in CFG e settare i seguenti parametri.
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Factory parameters family.
  Boiler Temperature Threshold.
5. Switch OFF and then switch ON the machine.
LS10 PROG 002
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters:
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Factory parameters family.
  Boiler Temperature Threshold.
5. Modify Cycle parameters:
 Cycle 1.
  Short Wash Phase [s].
 Cycle 2.
 Long Wash Phase [min]
  Short Wash Phase [s].
6. Switch OFF and then switch ON the machine
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 28 / 114
ECOTEMP12 PROG 003
1. Switch OFF and then switch ON the machine
2.  Enter into CFG parameter family and set the following parameters:
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Boiler heaters and tank heater work simultaneously. .
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Factory parameters family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
5. Switch OFF and then switch ON the machine.
LS12 AU / WT60 - 65 AU PROG 004
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters:
 Hood Type like working cycles.
 Atmospheric boiler.
 Automatic Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Factory parameters family.
  Boiler Temperature Threshold.
5. Modify the other parameters:
 Cycle 1.
 Final Pause [s].
 Cycle 2..
 Final Pause [s].
 Cycle 3.
 Final Pause [s].
 Dishwashing parameters family.
 Initial Pause.
6. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 29 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
PW 1 - 2 / WT830 – 850 PROG 005
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Pot Washer.
 Atmospheric boiler.
 Front loading function.
 Default values for Pot Washer models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Factory parameters family.
  Boiler Temperature Threshold.
5. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 30 / 114
WT60 - 65 USPH PROG 006
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Factory parameters family.
  Boiler Temperature Threshold.
5. Modify the cycle parameters:
 Enter into Cycle 1 parameters family.
  Rinse Phase Duration [s]
  Drain [s]
 Enter into Cycle 2 parameters family.
  Rinse Phase Duration [s].
  Drain [s].
 Enter into Cycle 3 parameters family.
  Rinse Phase Duration [s].
  Drain [s].
6. Select Fahrenheit:
 Enter into Dishwashing parameter family.
 Select Fahrenheit degrees.
7. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 31 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LS12HD PROG 007
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify the cycle parameters:
 Enter into Cycle 1 parameters family.
  Pre-rinse Duration [s].
  Drain [s].
 Enter into Cycle 2 parameters family.
  Pre-rinse Duration [s].
  Drain [s].
 Enter into Cycle 3 parameters family.
  Pre-rinse Duration [s].
  Drain [s].
5. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 32 / 114
LS10HD PROG 008
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters:
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify the cycle parameters:
 Enter into Cycle 1 parameters family.
  Short Wash Phase [s].
  Pre-rinse Duration [s].
  Drain [s].
 Enter into Cycle 2 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
  Pre-rinse Duration [s].
  Drain [s].
5. Switch OFF and then switch ON the machine.
LS12 - 14 / WT60 - 65 ASIA PROG 009
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Factory parameters family.
  Boiler Temperature Threshold.
 Boiler Priority Disabled.
5. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 33 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT65MED PROG 010
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters:
 Hood Type like working cycles.
 Atmospheric boiler.
 Automatic Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Factory parameters family.
  Boiler Temperature Threshold.
 Disable boiler high Temperature alarm (  ).
 Boiler Temperature Adjust.
 Booster Function.
  Tub Temperature: THRESHOLD.
  Tank high Temperature limit.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
  Rinse Phase Duration [s].
  Drain [s].
  Final Pause [s].
 Cycle 2 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
  Rinse Phase Duration [s].
  Drain [s].
  Final Pause [s].
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause [s]
 Set other parameters.
 Initial Pause [s].
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 34 / 114
LS6 6000W ATM PROG 011
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
LS5WS / WT4WS TRIFASE
(Up to Ser.Nr.:806) PROG 012
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading door type.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
  Select user interface for LS5 (up to version 3.11 set to ).
 Regeneration cycle enabled.
 ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
6. Switch OFF and then switch ON the machine.
7.  Enter into GEn parameter family.
  Initial Detergent Dosage [s].
 Initial Rinse Aid Dosage [s].
8.  Counters.
  Number of cycles allowed before regeneration.
9. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 35 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LS6 PRESS PROG 013
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Pressure boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
5. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 36 / 114
WT38MED PROG 014
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Disable boiler high Temperature alarm (  ).
 Boiler Temperature Adjust.
 Booster function not needed.
  During stand-by boiler is kept at lower temperature than Temperature Threshold.
  Tub Temperature Threshold.
  Tank high Temperature limit.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
6. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 37 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT38 USPH PROG 015
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 During stand-by boiler is kept at lower temperature than Temperature Threshold.
 Booster Function not necessary.
  Tank Temperature Threshold.
  High limit for tank temperature.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
  Rinse Phase Duration [s].
  Drain [s].
 Final Pause [s].
 Cycle 2 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
  Rinse Phase Duration [s].
  Drain [s].
 Final Pause [s].
 Cycle 3 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
  Rinse Phase Duration [s].
  Drain [s].
 Final Pause [s].
 Drain parameters family.
  Initial Drain Phase Duration [s].
 Set other parameters.
 Initial Pause [s].
 Fahrenheit.
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 38 / 114
ECOTEMP 5 PROG 016
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank and boiler heaters work simultaneously.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 During stand-by boiler is kept at lower temperature than Temperature Threshold.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min].
  Short Wash Phase. [s]
  Rinse Phase Duration [s].
  Drain [s].
 Final Pause [s].
 Cycle 2 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
  Rinse Phase Duration [s].
  Drain [s].
 Final Pause [s].
 Cycle 3 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
  Rinse Phase Duration [s].
  Drain [s].
 Final Pause [s].
 Drain parameters family.
  Initial Drain Phase Duration [s].
 Set other parameters.
 Initial Pause [s].
6. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 39 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT830EA / WT850EA
PW1EAG / PW2EAG PROG 017
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Automatic Pot Washer.
 Atmospheric boiler.
 Automatic Pot Washer
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
 Final Pause [s].
 Cycle 2 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
 Final Pause [s].
 Cycle 3 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
 Final Pause [s].
5. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 40 / 114
LS9 / WT 55 ATM PROG 018
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 2 parameters family.
  Short Wash Phase [s].
 Cycle 3 parameters family.
 Long Wash Phase [min].
6. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 41 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LS9 / WT 55 PRESS PROG 019
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Pressure boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 2 parameters family.
  Short Wash Phase [s].
 Cycle 3 parameters family.
 Long Wash Phase [min].
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 42 / 114
LS5 / WT4 PRES
(Up to Ser. Nr.: 806) PROG 020
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Pressure boiler.
 Front loading door type.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.
  Select user interface without display (up to version 3.11 set to ).
 Regeneration cycle enabled.
 ALARMS NOT ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
 Enter into GEn parameter family.
  Initial Detergent Dosage.
 Initial Rinse Aid Dosage.
  Detergent dispenser works when LOAD SOLENOID VALVE in activated.
  Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
8. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 43 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LS5 / WT4 MONO
(Up to Ser. Nr.: 806) PROG 021
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Pressure boiler.
 Front loading door type.
 Default values for Undercounter models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.
  Select user interface without display (up to version 3.11 set to ).
 Regeneration cycle disabled.
 ALARMS NOT ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
 Enter into GEn parameter family.
  Initial Detergent Dosage.
 Initial Rinse Aid Dosage.
  Detergent dispenser works when LOAD SOLENOID VALVE in activated.
  Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
8. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 44 / 114
LB5G / WT4 G PROG 022
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading door type.
 Default values for Undercounter models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.
  Select user interface for LS5 (up to version 3.11 set to ).
 Regeneration cycle disabled.
 ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
6. Switch OFF and then switch ON the machine.
7.  Enter into GEn parameter family.
  Initial Detergent Dosage [s].
 Initial Rinse Aid Dosage [s].
8. Switch OFF and then switch ON the machine..
DOC. NO. 5956.446.06 P. 45 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
ECOTEMP5 EAG PROG 023
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading door type.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Regeneration cycle disabled.
 ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
LS5WS / WT4 WS MONO
(Up to Ser. Nr.: 806) PROG 024
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading door type.
 Default values for Undercounter models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
  Select user interface for LS5 (up to version 3.11 set to).
 Regeneration cycle enabled.
 ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
6. Switch OFF and then switch ON the machine.
7.  Enter into GEn parameter family.
  Initial Detergent Dosage [s].
 Initial Rinse Aid Dosage [s].
8.  Counters.
  Number of cycles allowed before regeneration.
9. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 46 / 114
LS12 ECOTEMP (EUROPE) PROG 025
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank and boiler heaters work simultaneously.
  The tank is filled into the traditional way.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
5. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 47 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LS12 / ECOTEMP UK PROG 026
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Drain [s].
 Cycle 2 parameters family.
 Drain [s].
 Cycle 3 parameters family.
 Initial Drain Phase Duration [s].
 Drain parameters family.
  Initial Drain Phase Duration [s].
 Set other parameters.
  Drain Phase Duration at the end of washing phase. [s].
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 48 / 114
LS6AH PROG 027
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading door type.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 During stand-by boiler is kept at lower temperature than Temperature Threshold.
  Tank Temperature Threshold.
 HISTERESIS of Tank Temperature.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Cycle 2 parameters family..
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Set other parameters.
 Fahrenheit
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
 Enter into GEn parameter family.
 Detergent Dosage During Cycle Execution (during wash phase)
 Rinse Aid Dosage During Cycle Execution (when refilling boiler)
8. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 49 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LS14AH / WT65H PROG 028
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
  Tank Temperature Threshold.
 HISTERESIS of Tank Temperature.
  Tank high Temperature limit.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Cycle 2 parameters family.
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Cycle 3 parameters family.
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Set other parameters.
 Fahrenheit
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
 Enter into GEn parameter family.
 Detergent Dosage During Cycle Execution (during wash phase)
 Rinse Aid Dosage During Cycle Execution (when refilling boiler)
8. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 50 / 114
H3300 PROG 029
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 51 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
H1310SANA PROG 030
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Disable boiler high Temperature alarm (  ).
 Boiler Temperature Adjust.
 Booster function not needed.
  During stand-by boiler is kept at lower temperature than Temperature Threshold.
  Tub Temperature Threshold.
  Tank high Temperature limit.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 52 / 114
WT30H PROG 031
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading door type.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 During stand-by boiler is kept at lower temperature than Temperature Threshold.
  Tank Temperature Threshold.
 HISTERESIS of Tank Temperature.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Set other parameters.
 Fahrenheit
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
 Enter into GEn parameter family.
 Detergent Dosage During Cycle Execution (during wash phase)
 Rinse Aid Dosage During Cycle Execution (when refilling boiler)
8. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 53 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT38TDE PROG 032
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Medical line dishwasher with lock door/hood device.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Disable boiler high Temperature alarm ( ).
 Boiler Temperature Adjust.
 Booster function not needed.
  During stand-by boiler is kept at lower temperature than Temperature Threshold.
  Tub Temperature Threshold.
  Tank high Temperature limit.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle [s].
 Cycle 2 parameters family
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle [s].
 Cycle 3 parameters family
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle [s].
 Set other parameters.
  Duration of pause after the rinse cycle [s].
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 54 / 114
LS6MCD PROG 033
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 55 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT30M PROG 034
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Medical line dishwasher with lock door/hood device.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Disable boiler high Temperature alarm (  ).
 Boiler Temperature Adjust.
 Booster function not needed.
  During stand-by boiler is kept at lower temperature than Temperature Threshold.
  Tub Temperature Threshold.
  Tank high Temperature limit.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle [s].
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle [s].
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle [s].
 Set other parameters.
  Duration of pause after the rinse cycle [s].
 Fahrenheit
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 56 / 114
WT65M PROG 035
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Medical line dishwasher with lock door/hood device.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Disable boiler high Temperature alarm ( ).
 Boiler Temperature Adjust.
 Booster function not needed.
  During stand-by boiler is kept at lower temperature than Temperature Threshold.
  Tub Temperature Threshold.
  Tank high Temperature limit.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle [s].
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle [s].
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle [s].
 Set other parameters.
  Duration of pause after the rinse cycle [s].
 Fahrenheit
6. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 57 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LS5/1DPAUS
(Up to Ser.Nr.:806) PROG 036
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Pressure boiler.
 Front loading door type.
 Default values for Undercounter models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.
  Select user interface for LS5 (up to version 3.11 set to ).
 Regeneration cycle disabled.
 ALARMS NOT ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
 Enter into GEn parameter family.
  Initial Detergent Dosage.
 Initial Rinse Aid Dosage.
  Detergent dispenser works when LOAD SOLENOID VALVE in activated.
  Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
8. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 58 / 114
PW1-PW2 / WT830-WT850 USA PROG 037
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Pot Washer.
 Atmospheric boiler.
 Front loading function.
 Default values for Pot Washer models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature threshold.
  Boiler Temperature high limit.
 Boiler Temperature Adjust.
  Tub Temperature Threshold.
 HISTERESIS of Tank Temperature.
  Tank high Temperature limit.
5. Modify the cycle parameters:
 Cycle 1 parameters family..
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Final Pause at End of Cycle [s].
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Final Pause at End of Cycle [s].
 Cycle 3 parameters family.
  Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Final Pause at End of Cycle [s].
 Set other parameters.
 Fahrenheit.
6. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 59 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT30C (Cafè Line) PROG 038
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading door type.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 During stand-by boiler is kept at lower temperature than Temperature Threshold.
  Tank Temperature Threshold.
 HISTERESIS of Tank Temperature.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Final Pause [s]
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Final Pause [s]
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Final Pause [s]
 Set other parameters.
 Fahrenheit.
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 60 / 114
WT38PM50 / WT38PM60 PROG 039
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Pressure boiler.
 Front loading.
 Default values for Undercounter models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Boiler Temperature high limit.
  During stand-by boiler is kept at lower temperature than Temperature Threshold.
 Booster Function not necessary.
  Tank Temperature Threshold.
  High limit for tank temperature.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
 Final Pause [s]
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
 Final Pause [s]
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
 Final Pause [s]
 Drain parameters family.
  Initial Drain Phase Duration [s].
 Set other parameters.
 Initial Pause [s].
6. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 61 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LU7P / LU700P / WTU40P PROG 040
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Pressure boiler.
 Front loading.
 Default values for Hood Type models.
 SLOW SOFT START ENABLED
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold..
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 2 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
 Cycle 3 parameters family.
 Long Wash Phase [min].
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 62 / 114
LU7A / LU700A / WTU40A PROG 041
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Hood Type models.
 SLOW SOFT START ENABLED
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 2 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
 Cycle 3 parameters family.
 Long Wash Phase [min].
6. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 63 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LS14WS / WT65WS PROG 042
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
 Alarms enabled.
 Air gap with float level sensor normally closed.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Factory parameters family.
  Boiler Temperature Threshold.
 Drain parameters family.
  Final Drain Phase Duration [s].
5. Modify Communication and HACCP parameters:
 Enter into HCP parameter family and set the following parameters.
 Dishwasher with incorporated continuous water softener.
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 64 / 114
WT65MEDWS PROG 043
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters:
 Hood Type like working cycles.
 Atmospheric boiler.
 Automatic Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
 Alarms enabled.
 Air gap with float level sensor normally closed.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Factory parameters family.
  Boiler Temperature Threshold.
 Disable boiler high Temperature alarm (  ).
 Boiler Temperature Adjust.
 Booster Function.
  Tub Temperature: THRESHOLD.
  Tank high Temperature limit.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause [s]
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause [s]
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause [s]
 Drain/Cleaning Cycle Parameters.
  Drain without cleaning cycle.
 Set other parameters.
 Initial Pause [s]
6. Modify Communication and HACCP parameters:
 Enter into HCP parameter family and set the following parameters.
 Dishwasher with incorporated continuous water softener.
7. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 65 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LS6WS PROG 044
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Undercounter like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
 Alarms enabled.
 Air gap with float level sensor normally closed.
3. Switch OFF and then switch ON the machine.
4. Modify Communication and HACCP parameters:
 Enter into HCP parameter family and set the following parameters.
 Dishwasher with incorporated continuous water softener.
5. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 66 / 114
WT38MEDWS PROG 045
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Under counter like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
 Alarms enabled.
 Air gap with float level sensor normally closed.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Disable boiler high Temperature alarm (  ).
 Boiler Temperature Adjust.
 Booster function not needed.
  During stand-by boiler is kept at lower temperature than Temperature Threshold.
  Tub Temperature Threshold.
  Tank high Temperature limit.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
6. Modify Communication and HACCP parameters:
 Enter into HCP parameter family and set the following parameters.
 Dishwasher with incorporated continuous water softener.
7. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 67 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
FL620 / LV6 / WT30 6000W ATM PROG 046
1. Switch OFF and then switch ON the machine
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine
LU700A / ET7ADP PROG 047
1. Switch OFF and then switch ON the machine
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Hood Type models.
 SLOW SOFT START ENABLED
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 2 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
 Cycle 3 parameters family.
 Long Wash Phase [min].
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 68 / 114
FL620WS / LV6WS / WT38WS PROG 048
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Undercounter like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
 Alarms enabled.
 Air gap with float level sensor normally closed.
3. Switch OFF and then switch ON the machine.
4. Modify Communication and HACCP parameters:
 Enter into HCP parameter family and set the following parameters.
 Dishwasher with incorporated continuous water softener.
5. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 69 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
ET5EDF PROG 049
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min.]
 Short Wash Phase [s].
  Rinse Phase Duration [s].
  Drain [s].
 Final Pause [s].
 Cycle 2 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
  Rinse Phase Duration [s].
  Drain [s].
 Final Pause [s].
 Cycle 3 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
  Rinse Phase Duration [s].
  Drain [s].
 Final Pause [s].
  Boiler temperature[°C].
 Drain parameters family.
  Initial Drain Phase Duration [s].
 Set other parameters.
 Initial Pause [s].
5. Switch OFF and then switch ON the machine.
6. Modify Detergent dosage:
 Enter into GEn parameter family.
  Detergent dispenser works when WASHING PUMP in activated.
  Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
7. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 70 / 114
ET12EIF PROG 050
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
 Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
 Final Pause [s]
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
 Final Pause [s]
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
 Final Pause [s]
  Boiler temperature[°C]
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
 Enter into GEn parameter family.
  Detergent dispenser works when WASHING PUMP in activated.
  Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
8. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 71 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT37LEV/9 PROG 051
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify the cycle parameters:
 Drain/Cleaning Cycle Parameters.
 Drain without cleaning cycle.
5. Switch OFF and then switch ON the machine.
L14ROW / WT65ROW PROG 052
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Pressure boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Boiler Priority Disabled.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 2 parameters family.
  Short Wash Phase [s].
 Cycle 3 parameters family.
 Long Wash Phase [min].
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 72 / 114
LS6SANA PROG 053
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Medical line dishwasher with lock door/hood device.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Disable boiler high Temperature alarm ( ).
 Boiler Temperature Adjust.
 Booster function not needed.
  During stand-by boiler is kept at lower temperature than Temperature Threshold.
  Tub Temperature Threshold.
  Tank high Temperature limit.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
6. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 73 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LS14SANA PROG 054
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Medical line dishwasher with lock door/hood device.
 Atmospheric boiler.
 Manual hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Disable boiler high Temperature alarm (  ).
 Boiler Temperature Adjust.
 Booster function not needed.
  Tub Temperature Threshold.
  Tank high Temperature limit.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
  Final Pause at End of Cycle
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 74 / 114
WT38WL PROG 055
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Medical line dishwasher with lock door/hood device.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
  Disable boiler high Temperature alarm (  ).
 Boiler Temperature Adjust.
 Booster function not needed.
 During stand-by boiler is kept at lower temperature than Temperature Threshold.
  Tub Temperature Threshold.
 HISTERESIS of Tank Temperature.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
  Drain [s]
 Final Pause at End of Cycle [s].
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
  Drain [s]
 Final Pause at End of Cycle[s].
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
  Drain [s]
 Final Pause at End of Cycle [s].
 Drain parameters family.
  Initial Drain Phase Duration [s].
DOC. NO. 5956.446.06 P. 75 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT38WL PROG 055
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
 Enter into GEn parameter family.
  Initial Detergent Dosage.
 Detergent dispenser works when LOAD SOLENOID VALVE in activated.
8. Switch OFF and then switch ON the machine.
WT30HWS PROG 056
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading door type.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 ALARMS ENABLED.
 Air gap with float level sensor normally closed.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 During stand-by boiler is kept at lower temperature than Temperature Threshold.
  Tank Temperature Threshold.
 HISTERESIS of Tank Temperature.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 76 / 114
WT30HWS PROG 056
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Set other parameters.
 Fahrenheit.
6. Modify Communication and HACCP parameters:
 Enter into HCP parameter family and set the following parameters.
 Dishwasher with incorporated continuous water softener.
7. Switch OFF and then switch ON the machine.
8. Modify Detergent dosage:
 Enter into GEn parameter family.
 Detergent Dosage During Cycle Execution (during wash phase)
 Rinse Aid Dosage During Cycle Execution (when refilling boiler)
9. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 77 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WT65HWS PROG 057
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 ALARMS ENABLED.
 Air gap with float level sensor normally closed.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
  Tank Temperature Threshold.
 HISTERESIS of Tank Temperature.
  Tank high Temperature limit.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Cycle 2 parameters family.
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Cycle 3 parameters family.
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Drain parameters family.
  Final Drain Phase Duration [s].
 Set other parameters.
 Fahrenheit.
6. Modify Communication and HACCP parameters:
 Enter into HCP parameter family and set the following parameters.
 Dishwasher with incorporated continuous water softener.
7. Switch OFF and then switch ON the machine.
8. Modify Detergent dosage:
 Enter into GEn parameter family.
 Detergent Dosage During Cycle Execution (during wash phase)
 Rinse Aid Dosage During Cycle Execution (when refilling boiler)
9. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 78 / 114
ET12EWS PROG 058
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank and boiler heaters work simultaneously.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
 Alarms enabled.
 Air gap with float level sensor normally closed.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Factory parameters family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Drain parameters family.
  Final Drain Phase Duration [s].
5. Modify Communication and HACCP parameters:
 Enter into HCP parameter family and set the following parameters.
 Dishwasher with incorporated continuous water softener.
6. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 79 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
ET12EIWS PROG 059
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Manual Hood.
 Default values for Hood Type models.
 (for this appliance SOFT START is NOT possible).
 Tank and boiler heaters work simultaneously.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
 Alarms enabled.
 Air gap with float level sensor normally closed.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Factory parameters family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Drain parameters family.
  Final Drain Phase Duration [s].
5. Modify Communication and HACCP parameters:
 Enter into HCP parameter family and set the following parameters.
 Dishwasher with incorporated continuous water softener.
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 80 / 114
ET5EDWS PROG 060
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank and boiler heaters work simultaneously.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
 Air gap with float level sensor normally closed.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 During stand-by boiler is kept at lower temperature than Temperature Threshold.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
 Final Pause [s]
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
 Final Pause [s]
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
  Rinse Phase Duration [s]
  Drain [s]
 Final Pause [s]
 Drain parameters family.
  Initial Drain Phase Duration [s].
 Set other parameters.
 Initial Pause [s].
6. Modify Communication and HACCP parameters:
 Enter into HCP parameter family and set the following parameters.
 Dishwasher with incorporated continuous water softener.
7. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 81 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LU7ADPWS PROG 061
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Hood Type models.
 SLOW SOFT START ENABLED
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
 Air gap with float level sensor normally closed.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Cycle 3 parameters family.
 Long Wash Phase [min].
 Drain parameters family.
  Final Drain Phase Duration [s].
6. Modify Communication and HACCP parameters:
 Enter into HCP parameter family and set the following parameters.
 Dishwasher with incorporated continuous water softener.
7. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 82 / 114
LU700ADPWS PROG 062
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Hood Type models.
 SLOW SOFT START ENABLED
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
 Air gap with float level sensor normally closed.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Cycle 3 parameters family.
 Long Wash Phase [min]
 Drain parameters family.
  Final Drain Phase Duration [s]
6. Modify Communication and HACCP parameters:
 Enter into HCP parameter family and set the following parameters.
 Dishwasher with incorporated continuous water softener.
7. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 83 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LS5WS / WT4WS TRIFASE
(From Ser. Nr.: 807) PROG 063
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading door type.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.


ACTIVE function disabled (Up to Ser. Nr.: 820).
Select user interface for LS5 (From Ser. Nr.: 821).
 Regeneration cycle enabled.
 ALARMS NOT ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Cycle 2 parameters family
 Long Wash Phase [min]
  Short Wash Phase [s]
 Cycle 3 parameters family
 Long Wash Phase [min]
  Short Wash Phase [s]
6. Switch OFF and then switch ON the machine.
7.  Enter into GEn parameter family.
  Initial Detergent Dosage [s].
 Initial Rinse Aid Dosage [s].
8.  Counters.
  Number of cycles allowed before regeneration.
9. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 84 / 114
LS5 / WT4 PRES
(From Ser. Nr.: 807) PROG 064
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Pressure boiler.
 Front loading door type.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.


ACTIVE function disabled (Up to Ser. Nr.: 820).
Select user interface for LS5 (From Ser. Nr.: 821).
 Regeneration cycle enabled.
 ALARMS NOT ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
 Enter into GEn parameter family.
  Initial Detergent Dosage.
 Initial Rinse Aid Dosage.
  Detergent dispenser works when LOAD SOLENOID VALVE in activated.
  Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
8. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 85 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LS5 / WT4 MONO
(From Ser. Nr.: 807) PROG 065
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Pressure boiler.
 Front loading door type.
 Default values for Undercounter models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.


ACTIVE function disabled (Up to Ser. Nr.: 820).
Select user interface for LS5 (From Ser. Nr.: 821).
 Regeneration cycle disabled.
 ALARMS NOT ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
 Enter into GEn parameter family.
  Initial Detergent Dosage.
 Initial Rinse Aid Dosage.
  Detergent dispenser works when LOAD SOLENOID VALVE in activated.
  Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
8. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 86 / 114
LS5WS / WT4WS MONO
(From Ser. Nr.: 807) PROG 066
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading door type.
 Default values for Undercounter models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.


ACTIVE function disabled (Up to Ser. Nr.: 820).
Select user interface for LS5 (From Ser. Nr.: 821).
 Regeneration cycle enabled.
 ALARMS NOT ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 1 parameters family
 Long Wash Phase [min]
  Short Wash Phase [s]
 Cycle 2 parameters family
 Long Wash Phase [min]
  Short Wash Phase [s]
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
6. Switch OFF and then switch ON the machine.
7.  Enter into GEn parameter family.
  Initial Detergent Dosage [s].
 Initial Rinse Aid Dosage [s].
8.  Counters.
  Number of cycles allowed before regeneration.
9. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 87 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
LS5/1DPAUS (From Ser. Nr.: 807) PROG 067
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Pressure boiler.
 Front loading door type.
 Default values for Undercounter models.
 (for this appliance SOFT START is NOT possible).
 Tank heater works only if boiler temperature reached.
 The tank is filled into the traditional way.
 Detergent level switches not enabled.


ACTIVE function disabled (Up to Ser. Nr.: 820).
Select user interface for LS5 (From Ser. Nr.: 821).
 Regeneration cycle disabled.
 ALARMS NOT ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Cycle 3 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
 Enter into GEn parameter family.
  Initial Detergent Dosage.
 Initial Rinse Aid Dosage.
  Detergent dispenser works when LOAD SOLENOID VALVE in activated.
  Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
8. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 88 / 114
WT30H208DN / WT30H240DN PROG 068
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading door type.
 Default values for Undercounter models.
 SOFT START ENABLED.
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 ACTIVE function disabled (up to version 3.11 set to ).
 Regeneration cycle disabled.
 ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 During stand-by boiler is kept at lower temperature than Temperature Threshold.
  Tank Temperature Threshold.
 HISTERESIS of Tank Temperature.
5. Modify the cycle parameters:
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Cycle 1 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Pause [s]
  Rinse Phase Duration [s]
 Final Pause [s]
 Set other parameters.
 Fahrenheit.
 Rinse Temperature Display.
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
 Enter into GEn parameter family.
 Detergent Dosage During Cycle Execution (during wash phase)
 Rinse Aid Dosage During Cycle Execution (when refilling boiler)
8. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 89 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTU40A PROG 069
1. Switch OFF and then switch ON the machine
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Hood Type models.
 SLOW SOFT START ENABLED
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 2 parameters family.
 Long Wash Phase [min].
  Short Wash Phase [s].
 Cycle 3 parameters family.
 Long Wash Phase [min].
6. Switch OFF and then switch ON the machine.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 90 / 114
WTU40ADPWS PROG 070
1. Switch OFF and then switch ON the machine.
2.  Enter into CFG parameter family and set the following parameters.
 Hood Type like working cycles.
 Atmospheric boiler.
 Front loading.
 Default values for Hood Type models.
 SLOW SOFT START ENABLED
 Tank heater works only if boiler temperature reached.
  Enable filling tank by means of rinsing cycles.
 Detergent level switches not enabled.
 Select user interface hood type model (up to version 3.11 set to ).
 Regeneration cycle disabled.
 Alarms enabled.
 Air gap with float level sensor normally closed.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
 Enter into FAC parameter family and change boiler threshold.
  Boiler Temperature Threshold.
 Boiler Temperature Adjust.
 Booster Function.
5. Modify the cycle parameters:
 Cycle 2 parameters family.
 Long Wash Phase [min]
  Short Wash Phase [s]
 Cycle 3 parameters family.
 Long Wash Phase [min]
 Drain parameters family.
  Final Drain Phase Duration [s]
6. Modify Communication and HACCP parameters:
 Enter into HCP parameter family and set the following parameters.
 Dishwasher with incorporated continuous water softener.
7. Switch OFF and then switch ON the machine.
DOC. NO. 5956.446.06 P. 91 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
11 DEFAULT VALUES
Default 1 - HOOD TYPE
ON/OFF +
CYCLE1
keys
ON/OFF +
CYCLE2
keys
 
 
     
           
           
           
          
         
         
        
       
  
 
 
 
 
 

DOC. NO. 5956.446.06 P. 92 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
Default 2 - POT WASHER
ON/OFF +
CYCLE1
keys
ON/OFF +
CYCLE2
keys
 
 
     
           
           
           
          
         
         
        
       
  
 
 
 
 
 

DOC. NO. 5956.446.06 P. 93 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
Default 3 - UNDERCOUNTER
ON/OFF +
CYCLE1
keys
ON/OFF +
CYCLE2
keys
 
 
     
           
           
           
          
         
         
        
       
  
 
 
 
 
 

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 94 / 114
12 USER INTERFACE AND MAIN BOARD CONNECTORS
12.1 MAIN MALFUNCTIONS NOT DUE TO THE MAIN BOARD
12.2 CONNECTORS LAYOUT
KEY
CN1 Rinse pump/wash pump/solenoid valve outputs
CN2 Pressure/atmospheric dishwasher solenoid valve connection
CN3 Detergent/rinse aid dispenser outputs
CN5 Tank/boiler temperature sensor inputs
CN8 Energy peak controller input
CN12 User interface inputs/outputs
CN15 Overflow/tank level/board feed input
CN16 User interface inputs/outputs and hood/door sensor input
The display shows  with door/hood closed Check door/hood micro/sensor
No cycle starts Check the user interface buttons (have they remained
pressed? etc.)
A cycle fails to start Is a user interface button extension missing?
After replacing the main board only the 3rd cycle starts The main board is still configured for LS5/WT4.
Cycle time longer than that foreseen Does the boiler work?
Is the feed water at 50°C?
Noisy wash pump (only on HT and PP versions) Check the current for single phase during operation.
LAYOUT 1 LS10/LS12/WT60/HT1000/HT1200
DOC. NO. 5956.446.06 P. 95 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
KEY
CN1 Rinse pump/wash pump/solenoid valve outputs
CN2 Pressure/atmospheric dishwasher solenoid valve connection
CN3 ECOTEMP transformer and detergent/rinse aid dispenser outputs
CN5 Tank/boiler temperature sensor inputs
CN8 Energy peak controller input
CN12 User interface inputs/outputs
CN15 Overflow/tank level/board feed input
CN16 User interface inputs/outputs and hood/door sensor input
LAYOUT 2 WT65 MARINE
LAYOUT 3 ECOTEMP12 UK/LS14AH - WT65H/PW1M/PW2M/ET830M - E850M/
PW1 - PW2 USA/WT830 - WT850 USA/LV100M/LV200M
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 96 / 114
KEY
CN1 Rinse pump/wash pump/solenoid valve outputs
CN2 Pressure/atmospheric dishwasher solenoid valve connection
CN3 ECOTEMP transformer and detergent/rinse aid dispenser outputs
CN5 Tank/boiler temperature sensor inputs
CN7 Hand safety system microswitch input
CN8 Energy peak controller input
CN10 Safety and upper/lower limit switch input
CN11 Hand safety system input - Gear motor current control input - Gear motor polarity inversion connection
CN12 User interface inputs/outputs
CN15 Overflow/tank level/board feed input
CN16 User interface inputs/outputs and hood/door sensor input
ONLY
WS
LAYOUT 4 WT65/WT65MED/WT65WS/ET12E/ET12WS/HT1000/HT1200/HT1200WS/
LS14/LS14WS/LV1000/LV1200/LV1200VS
LAYOUT 5 WT830EA / WT850EA
DOC. NO. 5956.446.06 P. 97 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
KEY
CN1 Rinse pump/wash pump/solenoid valve outputs
CN2 Pressure/atmospheric dishwasher solenoid valve connection
CN3 Detergent/rinse aid dispenser outputs
CN5 Tank/boiler temperature sensor inputs
CN8 Energy peak controller input
CN11 Water feed solenoid valve output
CN12 User interface inputs/outputs
CN15 Overflow/tank level/board feed input
CN16 User interface inputs/outputs and hood/door sensor input
LAYOUT 6 WT65ROW/LS14ROW
LAYOUT 7 PPW1/PPW2 60Hz
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 98 / 114
KEY
CN1 Rinse pump/wash pump/solenoid valve outputs
CN2 Pressure/atmospheric dishwasher solenoid valve connection
CN3 ECOTEMP transformer and detergent/rinse aid dispenser outputs
CN5 Tank/boiler temperature sensor inputs
CN8 Energy peak controller input
CN12 User interface inputs/outputs
CN15 Overflow/tank level/board feed input
CN16 User interface inputs/outputs and hood/door sensor input
CN17 Door microswitch connection
LAYOUT 8 WT4G/LB5G/LS6A/LS6AWS/WT37/WT38/WT38WS/H1310/H3300/ETS/LV6A/LV6WS/FL6A/FL6WS
LAYOUT 9 WT38M/LS6AH - WT38H/WT30H WS
ONLY
WS
ONLY
WS
DOC. NO. 5956.446.06 P. 99 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
KEY
CN1 Rinse pump/wash pump/solenoid valve outputs
CN2 Pressure/atmospheric dishwasher solenoid valve connection
CN3 Detergent/rinse aid dispenser outputs
CN5 Tank/boiler temperature sensor inputs
CN8 Energy peak controller input
CN11 Door lock electromagnet output
CN12 User interface inputs/outputs
CN15 Overflow/tank level/board feed input
CN16 User interface inputs/outputs and hood/door sensor input
CN17 Door microswitch connector
LAYOUT 10 WT30M/LS6SANA/WT38TDE
LAYOUT 11 LS5/1 - WT4/1 - UC5/1
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 100 / 114
KEY
CN1 Rinse pump/wash pump/solenoid valve outputs
CN2 Pressure/atmospheric dishwasher solenoid valve connection
CN3 ECOTEMP transformer and detergent/rinse aid dispenser outputs
CN5 Tank/boiler temperature sensor inputs
CN8 Energy peak controller input
CN11 Hood lock electromagnet output
CN12 User interface inputs/outputs
CN15 Overflow/tank level/board feed input
CN16 User interface inputs/outputs and hood/door sensor input
LAYOUT 12 WT65M/LS14SANA
LAYOUT 13 LS9P/WT55P/WT55PM50/WT55PM60/H2500/HT900P/LV900P/LD900
DOC. NO. 5956.446.06 P. 101 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
KEY
CN1 Rinse pump/wash pump/solenoid valve outputs
CN2 Pressure/atmospheric dishwasher solenoid valve connection
CN3 ECOTEMP transformer and detergent/rinse aid dispenser outputs
CN5 Tank/boiler temperature sensor inputs
CN8 Energy peak controller input
CN10 Safety and upper/lower limit switch input
CN11 Hand safety system input - Gear motor current control input - Gear motor polarity inversion connection
CN12 User interface inputs/outputs
CN15 Overflow/tank level/board feed input
CN16 User interface inputs/outputs and hood/door sensor input
LAYOUT 14 WT60AU/LS12AU
LAYOUT 15 LS14AU/WT65A
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 102 / 114
KEY
CN1 Rinse pump/wash pump/solenoid valve outputs
CN2 Pressure/atmospheric dishwasher solenoid valve connection
CN3 Detergent/rinse aid dispenser outputs
CN5 Tank/boiler temperature sensor inputs
CN8 Energy peak controller input
CN9 Salt receptacle drain pump and low pressure solenoid valve outputs
CN11 Brine solenoid valve output
CN12 User interface inputs/outputs
CN15 Overflow/tank level/board feed input
CN16 User interface inputs/outputs and hood/door sensor input
CN17 Door microswitch connection
LAYOUT 16 WT4B/LS5P/LS6P/FL5P/LV5P/LD5P/FL620P/LV6P
LAYOUT 17 LS5WS/WT4WS/LV5WS/FL5WS
DOC. NO. 5956.446.06 P. 103 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
KEY
CN1 Rinse pump/wash pump/solenoid valve outputs
CN2 Pressure/atmospheric dishwasher solenoid valve connection
CN3 Detergent/rinse aid dispenser outputs
CN5 Tank/boiler temperature sensor inputs
CN7 Detergent/rinse aid level sensors input
CN8 Energy peak controller input
CN12 User interface inputs/outputs
CN15 Overflow/tank level/board feed input
CN16 User interface inputs/outputs and hood/door sensor input
CN17 Door microswitch connection
LAYOUT 18 WT38C/WT37LEV9/LS6MCD
LAYOUT 19 WT38PM50/WT38PM60
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 104 / 114
KEY
CN1 Rinse pump/wash pump/solenoid valve outputs
CN2 Pressure/atmospheric dishwasher solenoid valve connection
CN3 Detergent/rinse aid dispenser outputs
CN5 Tank/boiler temperature sensor inputs
CN8 Energy peak controller input
CN9 Salt receptacle drain pump and low pressure solenoid valve outputs
CN11 Brine solenoid valve output
CN12 User interface inputs/outputs
CN15 Overflow/tank level/board feed input
CN16 User interface inputs/outputs and hood/door sensor input
CN17 Door microswitch connection
LAYOUT 20 LS9UK
LAYOUT 21 WT4/1WS - LS5/1WS - UCS/1WS
DOC. NO. 5956.446.06 P. 105 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
KEY
CN1 Rinse pump/wash pump/solenoid valve outputs
CN2 Pressure/atmospheric dishwasher solenoid valve connection
CN3 Detergent/rinse aid dispenser outputs
CN5 Tank/boiler temperature sensor inputs
CN8 Energy peak controller input
CN12 User interface inputs/outputs
CN15 Overflow/tank level/board feed input
CN16 User interface inputs/outputs and hood/door sensor input
CN17 Door microswitch connection
LAYOUT 22 LU7A/WTU40A/LU7AWS/WTU40WS/ET7A
LAYOUT 23 LS9A/WT55A
ONLY
WS
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 106 / 114
KEY
CN1 Rinse pump/wash pump/solenoid valve outputs
CN2 Pressure/atmospheric dishwasher solenoid valve connection
CN3 Detergent/rinse aid dispenser outputs
CN5 Tank/boiler temperature sensor inputs
CN8 Energy peak controller input
CN12 User interface inputs/outputs
CN15 Overflow/tank level/board feed input
CN16 User interface inputs/outputs and hood/door sensor input
CN17 Door microswitch connection
LAYOUT 24 LU7P/WTU40P
DOC. NO. 5956.446.06 P. 107 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
13 ALARM MESSAGES AND TROUBLESHOOTING
13.1 ALARMS THAT STOP THE DISHWASHER
13.1.1 ALARM CODES FOR AUTOMATIC HOOD TYPE DISHWASHERS
When the alarm  appears, to facilitate fault-finding another parameter providing a more detailed indication
has been introduced.
The parameter is  and is found in the  family.
The possible cause of the anomaly can be found (see table below) according to the value of the parameter
.
With pot washers the cause that generated a  type alarm can also be found.
E.g.: With an automatic hood type the alarm  appears.
Access the parameter  in the  family.
 the top limit switch could be disconnected or interrupted.
 Want of water
Is the water cock open?
Does the water load solenoid valve work?
Is the water feed flow a min. of 5 l/min?
Is the water inlet filter clean?
Is the load solenoid valve filter clean?
Is the overflow inserted?
Is the main board (ATM-PRES) CN2 connector correctly positioned?
Do the tank/boiler pressure switches work properly?
 During rinse phase boiler doesn't empty
Are the rinse arms clogged?
Does the rinse pump work correctly?
Is there water in the level sensor tube?
Is there scale in the boiler?
Does the boiler level sensor work properly?
ONLY FOR MACHINES WITH CONTINUOUS WATER SOFTENER:
Does the boiler level sensor located inside the water softener work properly?
Does the float of the boiler level sensor, located inside the water softener, work properly? Is it free
to move upwards and downwards and vice versa?
Is the connection from the boiler level sensor to the main board efficient?
ATTENZIONE: RESETTING THIS ALARM WITHOUT FIRST ELIMINATING THE CAUSE IS
DANGEROUS; THE BOILER HEATING ELEMENTS COULD WORK DRY, FURTHER DAMAG-
ING THE INTERNAL PARTS OF THE DISHWASHER.
ATTENZIONE:  IT MUST BE MANUALLY RESET AFTER ELIMINATING THE CAUSE OF
THE MALFUNCTION.
 Automatic hood out of order
See par. 13.1.1 ALARM CODES FOR AUTOMATIC HOOD TYPE DISHWASHERS.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 108 / 114
Hood Pot Washer

Appears with hood closed if the top limit switch
(FC_UP) cuts in.
Appears with hood closed, if:
- the bottom limit switch (S3) returns to the rest
position;
- the top limit switch (S5) cuts in;
- S3’’ does not cut in.

During lifting, the bottom limit switch (FC_DW) has
not returned to the rest position.
The limit switch must return to the rest position
within a time given by the parameter  :
a) check that the motor works.

During the initial lifting phase the bottom limit
switch (S3) must return to the rest position
within a time given by the parameter  oth-
erwise the alarm appears.
- S3 could be stuck.
- S5’ could be disconnected.
On installation this alarm can occur due to
incorrect sequence of the phases: invert the two
phases on the power supply terminal board
 Appears if during lifting S3’’ does not return to
the rest position within a time .

Appears if the bottom limit switch (FC_DW) cuts in
during lifting.
(Polarity/motor rotation direction inverted?!).

Appears if the bottom limit switch (S3) cuts in
during lifting.
On installation this alarm can occur due to
incorrect sequence of the phases: invert the two
phases on the power supply terminal board.
S3: FC_DW
S5: FC_UP
(hood CLOSE)
(hood OPEN)
S1: DOOR_CLOSE
S4
S3''
S3
S3'
S5'
S5
S4'''
S4'' S4'
DOC. NO. 5956.446.06 P. 109 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

TIMEOUT-The time taken for hood lifting was
more than the time fixed by parameter  :
a) check that the motor works.
TIMEOUT- IThe time taken for lifting was more
than the time fixed by parameter .
Check correct operation of the:
a) motor (thermal protection N7);
b) top limit switch (S5 and S5’).

The hood is open but the bottom limit switch
(FC_DW) has cut in.
Appears with hood fully open, if:
- the limit switch (S5) returns to the rest posi-
tion;
- the bottom limit switch (S3) cuts in;
- S3’’ cuts in.
 Appears if with hood fully open the "door closed"
microswitch cuts in.
Appears if with hood fully open the "door
closed" microswitch cuts in.
- S5 could be disconnected.

During lowering, the top limit switch (FC_UP) has
not returned to the rest position.
The limit switch must return to the rest position
within a time given by parameter :
a) check that the motor works;
b) (Polarity/motor rotation direction inverted?!)..

During the initial lowering phase the top limit
switch (S5) must return to the rest position
within a time given by the parameter  oth-
erwise the alarm  appears.
- S5 could be stuck.
- S3’ could be disconnected.
On installation, this alarm can occur due to
incorrect sequence of the phases: invert the two
phases on the power supply terminal board.
 -Appears if the bottom limit switch S3 cuts in
before S3" during lowering.

Appears if the top limit switch (FC_UP) cuts in dur-
ing lowering.
(Polarity/motor rotation direction inverted?!).

Appears if the top limit switch (S5) cuts in dur-
ing lowering.
On installation, this alarm can occur due to
incorrect sequence of the phases: invert the two
phases on the power supply terminal board.

TIMEOUT- The time taken for hood closing was
more than the time fixed by parameter  :
a) check that the motor works.
TIMEOUT- The time taken for lowering was
more than the time fixed by parameter .
- S3’ could be disconnected.

-
Appears during hood lowering if, after S3’’ cuts
in, the bottom limit switch S3 does not cut in
within the time fixed by parameter .
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 11 0 / 11 4

-The two hand safety contacts K and K' must be
both closed or both open. If this does not occur
the alarm appears.
- One of the two relays (K or K’) could be stuck
or disconnected. (See parameter )

Limit switch combination not allowed:
top limit switch (FC_UP) and bottom limit switch
(FC_DW) activated at the same time!
Limit switch combination not allowed.
Appears if one of the following combina-
tions occurs:
- top limit switch (S5) and bottom limit switch
(S3) both activated (S3 and S5 could be dis-
connected);
- top limit switch S5 and S3’’ both cut in;
- bottom limit switch (S3) cut in but not S3’’.

During lifting, the current absorbed by the lifting
motor has exceeded the threshold (see parameter
):
a) excessive mechanical force during lifting..
-

During lowering, the current absorbed by the lifting
motor has exceeded the threshold (see parameter
):
excessive mechanical force during lowering.
-




The hood should be stopped but the card detects
a high current absorption by the lifting motor:
the relay RL18/RL19 could be stuck;
feeder connector CN32 could be disconnected.
-
DOC. NO. 5956.446.06 P. 111 / 114
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
13.2 ALARMS THAT DON'T STOP THE DISHWASHER
(SHOWN ON THE USER INTERFACE AT REGULAR INTERVALS)
WARNING:
Alarms marked with the ? symbol from Serial Number 821 have become alarms
which do not lock the machine.
 Drain not efficient
Has the overflow been removed?
Is the water drain blocked?
Is the drain pump blocked?
Are the air trap and tank pressure switch clean?
Is there a constriction in the drain tube?
Is the pump breather pipe returning to the tank clogged or constricted?
Does the tank pressure switch work properly?
Is there a hole in the drain tube (only for versions with drain pump)?
 Overflow alarm
Is the water drain blocked?
Are the air trap and tank pressure switch clean?
Does the tank pressure switch work properly?
Is the load solenoid valve blocked? (E1 - LOAD_EV)
Is the load solenoid valve relay stuck? (RL8 - LOAD_EV)
Θ  Boiler temperature rise too fast
Does the boiler level sensor work properly? The boiler could be empty.
Are non-original power resistances installed?
Θ  Boiler temperature too high
Has the boiler temperature been changed ( - increased above 90°C)?
Has the software alarm value been modified ()?
Does the boiler level sensor work properly?
Is the boiler relay stuck (see RL2, RL3, RL4)?
Θ  Tank temperature too high
Is the feed water above 60°C?
Has the software alarm value been modified ()?
Is the rinse water temperature too high?
Is the tank relay stuck (RL5 - TUB_HEAT)?
Θ  Tank temperature sensor out of order
Is the temperature sensor broken or disconnected (NT1)?
Is the temperature sensor connector correctly inserted?
Θ  Tank temperature sensor out of order
Is the temperature sensor short-circuited (NT1)?
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 11 2 / 11 4
WARNING:
Alarms ,  and  lock the boiler temperature control.
Alarms ,  and  lock the tank temperature control.
In the case of alarms  and , the boiler waiting phase is not executed (the rinse may be performed
with cold water) and, during the initial warm-up and subsequent rinses (  > ), the boiler heating
phase is not executed.
In the case of an open probe error ( ,  e  ), the displayed temperature is 10°C
In the case of a shorted probe error ( ,  e  ) , the displayed temperature is 99°C.
Θ  Boiler temperature sensor out of order
Is the temperature sensor broken or disconnected (NT2)?
Is the temperature sensor connector correctly inserted?
Θ  Boiler temperature sensor out of order
Is the temperature sensor short-circuited (NT2)?
Θ  Rinse temperature sensor out of order
(only on machines with temperature sensor on the rinse circuit)
Is the temperature sensor broken or disconnected?
Is the temperature sensor connector correctly inserted?
Θ  Rinse temperature sensor out of order
(only on machines with temperature sensor on the rinse circuit)
Is the temperature sensor short-circuited?
 Communication error
Is the connection between main board and control panel correct? Are the connectors correctly
connected?
Are connector contacts clean?
 Tank temperature low
Does the tank heating element work properly?
Are the connectors correctly connected?
Are the dishwasher feed voltage and current correct?
Is the relay RL5 on the board disconnected or faulty?
 Boiler temperature low
Does/do the boiler heating element/s work properly?
Are the connectors correctly connected?
Does the possible remote control switch connected to the heating element work correctly?
Is there power at the remote control switch input terminals?
Does relay RL2 on the board work properly?
CAUTION: IF THERE IS A MALFUNCTION ON RELAY RL2 AND THE BOILER HEATING ELE-
MENTS ARE FED BY MEANS OF A REMOTE CONTROL SWITCH, THE BOARD DOES NOT
HAVE TO BE REPLACED; JUST MOVE THE BOILER HEATING ELEMENT CONNECTOR TO
ONE OF THE TWO FREE POSITIONS ON THE BOARD.
CAUTION: WHEN ONE BRANCH OF THE HEATING ELEMENT DOES NOT WORK AND THE
OTHER TWO CONTINUE TO FUNCTION, ON REACHING THE SET TEMPERATURE VALUE,
ALARM 3 DISAPPEARS AND REAPPEARS IN THE SUBSEQUENT RINSE PHASE. THIS
ALSO OCCURS WHEN A PHASE IS MISSING.
DOC. NO. 5956.446.06 P. 11 3 / 11 4
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
13.3 ALARMS THAT DON’T STOP THE DISHWASHER FOR MODELS WITH
INCORPORATED CONTINUOUS WATER SOFTENER
WARNING:
Alarms marked with the Θ symbol from Serial Number 821 have become alarms
which do not lock the machine.
To facilitate the finding of faults signalled by alarm , another parameter providing a more detailed indication of the
possible cause of malfunction has been introduced in the family (see table below).
To reset error  it is necessary to disconnect and reconnect the main power supply to the machine by means
of the main switch on the external power board.
If alarm  or  appears, the machine indicates it on the display at regular intervals and auto-config-
ures itself in the same way as a machine without water softener. Resin regeneration cycles are not per-
formed and the column used for filling is always the same (column B).
Alarm  is reset when the machine is switched off and on from the mains switch (only if the causes that
generated it have been eliminated).
Alarm  is reset when the machine is switched off and on from the user interface or from the main switch
(only if the causes that generated it have been eliminated).
Θ  Water softener operation errors
This alarm appears in case of malfunctioning in the continuous water softener.
To reset error  it is necessary to disconnect and reconnect the main power supply to
the machine by means of the main switch on the external power board.
Θ  Communication errors between the mother board and soft-
ener board
This alarm appears in case of problems in communication between the mother board and water
softener board; check the connection between mother board connector J1 and water softener
connector ST8
 Water softener conductivity sensor short-circuit
Two or more water softener conductivity sensors are short-circuited. Check the connections
between the water softener board and sensors, replacing the connection wiring if neces-
sary.
 Water softener conductivity sensors open
One or more water softener conductivity sensors are disconnected. Check the connections
between the water softener board and sensors, replacing the connection wiring if neces-
sary.
 Resin temperature sensor malfunction
Replace the water softener electronic board.
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.446.06 P. 11 4 / 11 4
14 LIST OF PARAMETERS FOR SUBSEQUENT VERSIONS
The parameters listed below, even if present inside the software, cannot be used in appliances currently in
production.
Family :
parameter 
value 
Family 
Family  - alarm 
parameter , the maximum value it can be set to is 3, but actually the only significant values are 0
and 1. By setting  to 3, alarm F8 may appear, also implemented by the firmware, but not used in
any current application.
 Water softener electronic board malfunction
Replace the water softener electronic board.
 Salt water filling malfunction
(  up to
version 4.01)
The salt water container in the water softener was not completely filled within the
set max. filling time.
Make sure:
- the water cock is open
- the water filling solenoid valve works correctly
- the salt container solenoid valve works correctly
- the feed water pressure is at least 50 kPa / 0.5 bar
- the water inlet filter is clean
- the filling solenoid valve filter is clean
- the salt container cap is properly closed
- the mother board (ATM-PRES) connector CN2 is correctly positioned
- the water softener board connector ST5 is correctly positioned
- the grille on the bottom of the salt container is clogged with dirt.
 Inefficient resin washing
After carrying out the maximum permissible number of resin washes, the resins are not suf-
ficiently cleaned by the salt water used to regenerate them.
Make sure:
- the water filling solenoid valve works correctly
- the feed water pressure is at least 50 kPa / 0.5 bar
- the water inlet filter is clean
- the filling solenoid valve filter is clean
- the mother board (ATM-PRES) connector CN2 is correctly positioned.

Navigation menu