Chapter 8 Ch8
User Manual: Chapter 8 C-more Micro-Graphic Panel User Manual and Quick Start Guide
Open the PDF directly: View PDF .
Page Count: 10
Download | |
Open PDF In Browser | View PDF |
Troubleshooting Chapter 8 In this Chapter... C-more Micro-Graphic Panel does not Power up................................................ 8-2 Display is Blank.................................................................................................... 8-2 Display is Dim...................................................................................................... 8-3 No User Program.................................................................................................. 8-3 Lost Firmware – Red ‘Update Mode’ Screen Displayed...................................... 8-4 No Communications between Panel and PC (Personal Computer)................... 8-5 No Communications between Panel and PLC.................................................... 8-7 Panel & PLC Error Codes.................................................................................... 8-8 C-more Micro-Graphic Panel Runtime Errors..................................................... 8-9 Panel Errors........................................................................................................... 8-9 Electrical Noise Problems................................................................................... 8-10 Chapter 8: Troubleshooting 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D Troubleshooting 8-2 The following are some common problems that may be encountered during the installation and operation of your C-more® Micro-Graphic panel. We have made some suggestions on what to check in order to correct the problem. C-more Micro-Graphic Panel does not Power up Powered from 5 VDC: If the panel’s display is blank, not responding, and the panel is powered from a 5 VDC power source, check the incoming DC voltage level with a voltmeter. The DC voltage level should be in the range of 4.75 to 5.25 VDC. If the incoming DC voltage is zero, check any fusing that may be in the circuit. If the fuse is open, determine cause and replace. Powered from 12-24 VDC: If the panel’s display is blank, not responding, and the panel is powered from one of the optional DC Power Adapter modules, such as an EA-MG-P1 or EA-MG-SP1, check the incoming DC voltage level to the adapter with a voltmeter. The DC voltage level to the adapter should be in the range of 10.8-26.4 VDC. If the incoming DC voltage is zero, check any fusing that may be in the circuit. If the fuse is open, determine cause and replace. Display is Blank Also if the panel’s display is blank, check the TxD and RxD indicators on the back side of the panel while the panel is communicating with the PLC. The LED indicators should be on or flashing at a fast rate. Indicator activity shows that the panel is communicating with the PLC. If there is communication activity, but the display is still blank, there is the possibility the program in the PLC is controlling the display. Try pressing the F1 and F5 keys simultaneously for 3 seconds. The panel should display the System Setup Screen menu if the screen is being forced to display a blank by the PLC program, or check the PLC program, it may have the TxD Indicator RxD Indicator screen in the off state by placing a 0 in the current screen tag. ® EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17 Chapter 8: Troubleshooting Display is Dim Press the F1 and F5 keys simultaneously for 3 seconds to access the System Setup Screen menu. Select the Setting menu, and then select item 1, LCD Contrast. The default value is 3. Adjust the current value from 1 to 5 and the panel’s contrast should become greater as the value moves toward 5 and it should become less as the value moves toward 1. If this does not happen, then the panel may need to be replaced. LCD CONTRAST SETTING 1.LCD Contrast 2.Backlight 3.Beep 4.Calibration 5.Clear User Memory > > > BAK NXT UP DWN ENT BAK -- UP DWN APL F1 F2 F3 F4 F5 F1 F2 F3 F4 F5 Current Value: 3 No User Program If the panel is displaying the message “No User Program” after it is powered up, then there is no project downloaded into the panel. Using the EA-MG-PGMSW C-more Micro-Graphic Programming Software, download your project to the panel. SETUP MENU 1.Information 2.Setting NO USER PROGRAM 3.Test Menu 4.Exit ® > > > BAK – UP DWN ENT F1 F2 F3 F4 F5 EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 8-3 Chapter 8: Troubleshooting Lost Firmware – Red ‘Update Mode’ Screen Displayed 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 8-4 If the C-more Micro-Graphic panel’s firmware becomes corrupted or for some reason is lost from the panel’s memory, the panel will display the Update Mode screen as shown below. This can happen if communication between the PC and the panel is interrupted during a firmware update from the programming software. To resolve the problem, try the following steps in the order shown: 1.) Cycle power to the panel. 2.) Attempt to reload the firmware to the panel using the Update Firmware utility under the Panel pull down menu in the EA-MG-PGMSW Programming Software. 3.) If the firmware update is not successful, depress function keys F1 and F5 while cycling power to the panel. The panel should come up in the red Update Mode screen as shown below. Perform Step 2 again. 4.) Call Tech Support @ 770-844-4200. = Update Mode = Port1 [ 6pin] 115.2K/8/0/1 Port2 [15pin] 115.2K/8/0/1 Data Change Push Key1 F1 ® F2 F3 F4 F5 EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17 Chapter 8: Troubleshooting No Communications between Panel and PC (Personal Computer) The C-more Micro-Graphic panel is programmed using the C-more Micro-Graphic Programming Software, EA-MG-PGMSW. The developed project is transferred from the PC to the panel by a USB to RS-232 serial communications cable. The EA-MG-PGM-CBL Serial Programming Cable Assembly can be used to accomplish the interface between the PC and panel. Installing the programming software also installs a USB driver on the PC. When properly installed the programming cable will look like a serial communications port to the PC. USB to RS-232 Programming Cable Assembly PC to Panel Programming Cable Assembly (Includes serial & USB cables) p/n EA-MG-PGM-CBL User PC Serial Cable USB Cable USB to RS232 Converter C-more Micro-Graphic Panel NOTE: The panel has one built-in RJ12 serial communications port (Port 1 - RS-232) and the option to add one 15-pin serial communications port (Port 2 - RS-232/422/485) to the panel by installing the EA-MG-SP1 module. Only one of the ports can be used with a connected PLC. The programming software allows the user to select either Comm. Port1 or Comm. Port2 under the Panel Manager dialog box. When using Port 2 to communicate with the connected PLC, Port 1 can still be used with the EA-MG-PGM-CBL Software Programming Cable Assembly to transfer projects between the PC and panel. NOTE: If either DC power adapter is installed on the panel, the adapter must be powered and the panel not dependent on +5 VDC from the PLC’s RJ12 comm port. No communications between panel and PC continued top of next page. ® EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 8-5 Chapter 8: Troubleshooting No Communications between Panel and PC (Personal Computer) (cont’d) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 8-6 There are three possible causes that prevent transferring the project to the C-more MicroGraphic panel. 1. Panel not on setup screen (press F1 and F5) - Press and hold the F1 and F5 buttons simultaneously for three seconds to enter the setup screen. 2. Cable not connected - Double check the programming cable asembly to make sure the panel is correctly connected to the USB port on the PC. 3. Not using the correct com port assigned to the USB adapter - If the C-more Micro-Graphic panel is on the setup screen and the cable connection is correct, then check the PC COM port setting. If you are unsure which COM port the C-more Micro-Gaphic programming cable is connected to, click on the Device Manager button. This will open Windows ® Device Manager. In the Device Manager window, view the active avaiable ports by clicking the + button beside the Ports (COM & LPT) menu item. The C-more Micro-Graphic panel uses a USB driver called Koyo USB-Serial Comm Port. COM4 is the comm port used in this example. If you cannot find the Koyo USB-Serial Comm Port under the Ports (COM & LBT) menu item in Device Manager, the USB driver may not be correctly installed or the driver has a problem. See the software installation manual for details on installing the Koyo USB-Serial Comm Port driver. If you have selected the correct COM port and the error still occurs, try connecting the programming cable to a different USB port on the PC and try again. If the program persists, call Technical Support at (770) 844-4200, available from 9:00 A.M. to 6:00 P.M. Eastern Time. ® EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17 Chapter 8: Troubleshooting No Communications between Panel and PLC The communications between the C-more Micro-Graphic panel and a designated PLC or controlling device can be accomplished using the panel’s built-in RS-232 RJ12 serial communications port (Port 1) or by installing a EA-MG-SP1 Serial Port with DC Power Adapter module (Port 2) to the rear of the panel. The EA-MG-SP1 includes a 15-pin connector that can be connected for RS-232, RS-485 or RS-422. TxD Indicator Port 1: If you are using Port 1 then check the Txd and Rxd status indicators on the back side of the panel. They should be on or flashing at a fast rate. If there is activity on the LED indicators, then the panel and PLC are communicating. Location of Port 1’s LED status indicators shown to the right. Port 2: If you are using Port 2 then check the Txd and Rxd status indicators on the back side of the EA-MG-SP1 Serial Port with DC Power Adapter. They should be on or flashing at a fast rate. If there is activity on the LED indicators, then the panel and PLC are communicating. Location of Port 2’s LED status indicators shown to the right. RxD Indicator TxD Indicator RxD Indicator Port 2 On either serial communications port, if there is no activity on one or both TxD and RxD LED status indicators, then: • Verify that the communication settings are correct in the panel manager • Test or replace the cable. • Test the panel or adapter’s serial port (Page 5-14 & 5-15). • Test the serial port on the PLC. Electrical noise, pulse generating wiring and/or improper grounding can also cause problems with communications. Refer to the Electrical Noise Problems section in this chapter for additional help if electrical noise is suspected. ® EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 8-7 Chapter 8: Troubleshooting Panel & PLC Error Codes 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 8-8 The C-more Micro-Graphic panel includes built-in PLC communication protocol diagnostics that monitor the exchange of data between the panel and the PLC. The diagnostics look for the proper exchange of data, correct handshaking signals, addressing errors, incorrect data bytes, wrong packet format, etc. The diagnostics also monitor and display any of the errors that the designated PLC would normally generate if there is a problem with the PLC’s communications. The PLC generated errors are interpreted by the C-more Micro-Graphic programming software and are displayed across the top of the panel’s display embedded as a hexadecimal value in error code P499. If a C-more Micro-Graphic communications error does occur, the error message will be displayed in the upper left of the panel’s display screen along with the error code number. The error code with error message will blink off and on. A detailed list and description of the various PLC protocol errors can be found in Appendix A: Panel & PLC Error Code Tables. Panel Error Code Table Example: C-more Micro-Graphic Panel Error Table Error Code Error Message Cause P001 PLC Com Time Out A timeout occurred after sending a request to the PLC. P499 ErrCode Received -> A PLC generated error code with a hexadecimal value of XXXX has been Recv .Err Code XXXX returned from the PLC. PLC Error Code Table Example: PLC Error Codes for Direct LOGIC – ModBus (Koyo) Panel Error Code P499 Hex Value Description 0x1 The function code is unknown by the server. 0x4 The server failed during the execution. Note: See Appendix A: Panel & PLC Error Code Tables for a complete list of all error codes. Panel Communications Error Code Example P001: PLC COM Time Out Stop Start F1 ® F2 F3 F4 F5 EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17 Chapter 8: Troubleshooting C-more Micro-Graphic Panel Runtime Errors The C-more Micro-Graphic panel includes built-in diagnostics that check for proper operation of the panel when it is running a project that has been transferred to its memory. Faults detected while the panel is running will produce a “Runtime” error. These errors are displayed in a popup window in the center of the panel’s display. Troubleshooting a Panel Runtime Error: Follow these steps to troubleshoot a panel runtime error. 1. Check the panel cable connections. 2. Cycle power at the panel. 3. Resend the project. 4. If the error still occurs, reset the panel back to factory default. Refer to Chapter 5 for details NOTE: User memory is cleared when factory defaults are reset. Use the C-more Micro-Graphic programming software to read the program from the panel and save a backup copy. Panel Errors If more than one panel error occurs, each error message will display sequentially for three seconds with a two second delay between each message. When only one panel error is active, that message will display continuously until it is no longer active. Micro-Graphic Panel Errors Error Code Error Message Possible Solutions R001 PC software tool Timeout R002 CRC Error occurred during project transfer from PC. R003 R006 Project Check Sum Error. Resend Project file to Panel. Protocol Module Check Sum Error. Resend Project File to Panel Panel Check Sum Error. Panel Info (Not Project) will be initialized. SW Ver. Mismatch. Use software Ver.xx.xx. Check cables and connections. Cycle power at the panel. See Chapter 8 for Electrical Noise Problems. Check the area for sources of noise: electrical motors, transformers, etc. Check for proper grounding Resend the project. R100 Option module detected without external power R004 R005 R101 Cycle power. Resend the project. From the Setup Menu screen, reset panel options. Update to current version programming software and panel firmware. EA-MG-SP1 or EA-MG-P1 optional power adapter module is installed on a C-more 3” Micro-Graphic panel without a 12-24 VDC power source. Provide 12-24 VDC power to the optional module. EA-MG-SP1 or EA-MG-P1 optional power adapter module for a C-more Unsupported module detected 3” Micro-Graphic panel is installed on a C-more 6” Micro-Graphic panel. Remove the EA-MG-SP1 or EA-MG-P1. ® EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 8-9 Chapter 8: Troubleshooting Electrical Noise Problems 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 8-10 Noise is one of the most difficult problems to diagnose. Electrical noise can enter a system in many different ways which fall into one of two categories, conducted or radiated. It may be difficult to determine how the noise is entering the system but the corrective actions for either of the types of noise problems are similar. • Conducted noise is when the electrical interference is introduced into the system by way of an attached wire, panel connection, etc. It may enter through a power supply connection, the communication ground connection, or the chassis ground connection. • Radiated noise is when the electrical interference is introduced into the system without a direct electrical connection, much in the same manner as radio waves. While electrical noise cannot be eliminated, it can be reduced to a level that will not affect the system. • Most noise problems result from improper grounding of the system. A good earth ground can be the single most effective way to correct noise problems. If a ground is not available, install a ground rod as close to the system as possible. Ensure all ground wires are single point grounds and are not daisy chained from one device to another. Ground metal enclosures around the system. A loose wire can act as a large antenna, introducing noise into the system. Therefore, tighten all connections in your system. Loose ground wires are more susceptible to noise than the other wires in your system. Review Chapter 4: Installation & Wiring if you have questions regarding how to ground the touch panel. • Electrical noise can enter the system through the power source for the C-more Micro-Graphic panel. Installing a properly wired isolation transformer (neutral grounded) for all AC sources can help the problem, but only if wired correctly. DC sources should be well-grounded good quality supplies. • Never run communication cables or low-voltage power wiring close to high voltage wiring or pulse generating wiring that controls such devices as solenoids, servos, VFOs, etc. Selecting a lower communication rate in Panel Manager may help the panel resist noise. ® EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.6-c011 79.156289, 2014/03/31-23:39:12 Create Date : 2017:08:31 14:13:08-04:00 Metadata Date : 2017:08:31 14:13:11-04:00 Modify Date : 2017:08:31 14:13:11-04:00 Creator Tool : Adobe InDesign CC 2014 (Windows) Instance ID : uuid:f93f4c13-b975-44f5-85f3-51f4c96e419d Original Document ID : xmp.did:235E83094E7EE511855985A8C571BB7D Document ID : xmp.id:6195062e-1361-db4d-82f5-1b65cf27a8c1 Rendition Class : proof:pdf History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Windows) History Changed : / History When : 2017:08:31 14:13:08-04:00 Derived From Instance ID : xmp.iid:573b725c-cd74-3647-86e6-9b1e8016d4e8 Derived From Document ID : xmp.did:235E83094E7EE511855985A8C571BB7D Derived From Original Document ID: xmp.did:235E83094E7EE511855985A8C571BB7D Derived From Rendition Class : default Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 10 Creator : Adobe InDesign CC 2014 (Windows)EXIF Metadata provided by EXIF.tools