CI
-
150t
Portable Particle Counter
CLiMET’s CI-150t
Lightest and most user friendly !
CLiMET’s CI-150t is your best choice when Buying a
1CFM particle counter to monitor and validate a clean room
environment. The CI-150t is lightweight, portable
and intuitive. The CI-150t provides an ease of use
previously not available with particle counters.
It’s simplicity significantly reduces training time
for new operators.
CLiMET’s CI-150t will perform either Fed. Std. 209E, ISO 14644, or GMP calculations on acquired data
then provides a “pass/fail” report. With the color display, thermal printer and RS-232 connections, you
are able to receive visual, hard copy and digital verification of your clean room environment.
The CI-150t improves upon the Climet tradition of designing particle counters that test your clean room,
not your operators.
Please call, FAX, e-mail or visit our website to arrange for a free demonstration.
CLiMET Instruments Company 1320 West Colton Ave., Redlands, CA 92374 U.S.A.
T: (909) 793-2788 F: (909) 793-1738 E-mail: sales@climet.com Web site: www.climet.com
KEY FEATURES
Longer Battery Life
Bright and Beautiful TFT Display
Stainless Steel and Lightweight
External Horn with Volume Adjustment
TOUCHSCREEN INTERFACE
Graphical User Interface
Quick and Simple Setup
Simple Adjustments
Easier to input settings
Simpler Navigation
COLOR DISPLAY
Bright and Beautiful
Easy to Read
Reduces input Errors
STAINLESS STEEL
ENCLOSURE
Rugged
Stands up to Daily Cleaning
Reduces chance of ESD
KEY BENEFITS
Easy to Learn
Easy to Use
Easy to Carry
Samples Lon
g
er on a Sin
g
le Char
g
e
CLiMET Instruments Company
1320 W. Colton Ave., Redlands, CA 92374 U.S.A.
T: (909) 793-2788 F: (909) 793-1738
E-mail:sales@climet.com Web: www.climet.com
CLiMET is Particle Counting
MODEL CI-150t SPECIFICATIONS
SIZE SENSITIVITY: 0.30 μm
PARTICLE CHANNEL SIZES: Four sizes: 0.3, 0.5, 1.0, and 5.0 μm
SIZE RESOLUTION: 0.03 μm @ 0.33 μm (Ellipsoidal Mirror Collection System)
CONCENTRATION LIMIT: 106 Particles/ft³ @ 10%, 5x105 /ft³ @ 5%
SAMPLE FLOW RATE: 1.0 CFM (28.3 Liters per minute)
FLOW RATE CONTROL: Electronic, automatic closed loop. (Patented DC Blower System)
SAMPLE TUBE EXTENSION: 3/8” (9.525 mm) I.D., up to 20 ft. (6.1 meters) max. length
ZERO COUNT: < 1 count per 5 minutes, as per JIS 9971
BATTERY: Replaceable 9.6 Volts, 12.6 Amp hour Nickel Metal Hydride
Battery operation time: 5 to 6 hours of continuous operation
Time to charge battery: 3.0 to 3.5 hours
DISPLAY: Color TFT, ¼ VGA touch screen
PRINTER: Thermal Dot Matrix
MEMORY: 3,000 samples: Date, Time, 4 Particle Channels, Analog Channels,
Flow, ID, Sample Volume. Transferable to PC via RS-232 serial port.
UNIT ID User selectable
USER ID Up to 20 users with password authentication
SECURITY Four security levels with user authentication
LOCATION ID: Up to 100 per program; 16 characters long.
PROGRAM: Up to 30 user-defined and named, containing ID’s and settings.
REPORTS All data, Alarm data, Average data, FS-209E, ISO 14644, GMP
Reports include Unit and User ID’s
DATA INPUT/OUTPUT: RS-232
BEEP ON COUNT: 0.3 μm and greater.
AUDIBLE ALARM: Built-in
ALARM LIMITS: Programmable for all particle channels, Analog inputs, and flow.
DIMENSIONS: H-W-D: 8.65 X 8.5 X 9.5 inches (22 X 21.6 X 24.1 cm)
WEIGHT: 11.0 lb (4.99 Kg) without battery
14.25 lb (6.46 Kg) with battery
POWER: Auto switching: 85–260 VAC, 50/60 Hz
FUSES: two 5 X 20 mm, T 250C/1.0 Amp
OPERATING RANGE: 0–36º C, 10–90% RH, non-condensing
CALIBRATION: Factory Prime Calibration with monodisperse polystyrene latex spheres
traceable to NIST.
CALIBRATION FREQUENCY: Recommended every 12 months.
GAS COMPATIBILITY: Air, nitrogen; consult factory regarding other gases.