GlasGrid® System Installation Guide CompuGrid Systems CG100 Compoinstall
User Manual: CG100
Open the PDF directly: View PDF .
Page Count: 1
Download | |
Open PDF In Browser | View PDF |
GG_IG_CG_2.07 3/16/07 11:19 AM Page 1 > Pavement Reinforcement Mesh Installation Procedures for CompoGrid Systems The following are general guidelines to ensure a successful installation of CG50 and CG100. For each specific project, a construction engineer will provide exact specifications for installation. Surface Preparations • As directed by an engineer, repair potholes, cracks greater than 6mm* ( 1/4 in.**), badly damaged or rough pavement that may require milling and the placement of a leveling course. • Pavement must be free of dirt, water, oil and other foreign materials. Broom or air clean the surface so it is clean and dust-free. • Apply tack coat uniformly over the prepared asphaltic concrete surface at a residual rate of 0.9–1.36 litres/m2 (0.2–0.3 gal/yd2 ) using a calibrated distributor truck, ensuring that the application rate remains constant. The tack shall contain a minimum of 70% solids. Road Surface Condition • The road must be dry. Do not install CG50 or CG100 during any precipitation. • The road surface temperature must be between 5°C (40°F ) and 60°C (140°F ). On asphalt surfaces less than 24 hours old, the surface temperature shall be between 5°C and 46°C (40°F and 110°F ). CG Placement Method • Place the CG system while the tack coat is still tacky/ broken. Use a mechanical placement tractor or place manually. • Keep the material flat and wrinkle free. Installation may require hand brooming. For sharp curves, cut edges and fold over in the direction of the placement of asphalt overlay. • Overlaps must be a minimum 25mm (1 in.) to ensure a continuous moisture barrier. Tensar International Corporation 5883 Glenridge Drive, Suite 200 Atlanta, Georgia 30328 800-TENSAR-1 www.tensar-international.com Exclusive distributors in the Americas for: Fabric Tractor Manual Placement Procedure Paving Method 1. Pave with hot mix overlay. 2. Asphalt overlay must be a minimum of 50mm (2 in.) compacted thickness. 3. All of the CG system must be paved over on the day of placement. Important Issues 1. Because glass is a skin irritant, workers shall wear gloves while handling CG. 2. To cut CG to the desired length, lay it over ironworks, roll and then cut using a sharp utility knife. 3. CG must be applied so that the material lies flat on the road surface with no ripples. Providing sufficient tension during application will eliminate ripples. 4. Overlap all end roll joints 75–150mm (3 in.– 6 in.). Ensure that the overlaps are shingled in the direction of paving and that these overlaps also receive an application of tack. 5. Overlap longitudinal joints 25–50mm (1 in.–2 in.). 6.To maximize product performance, only construction and emergency vehicles shall be allowed to drive on the CG. These directions are a brief guide to installation. For complete directions, consult with your CG distributor. *All metric values are nominal. **All imperial values are approximate. GlasGrid® is the registered trademark of Saint-Gobain Technical Fabrics (SGTF). U.S. Patent 4699542/4957390/5110627/5393559. Canadian Patent 1240873. European Patent EP0318707. Japanese Patent 2611064. ©2004 Saint-Gobain Technical Fabrics. GlasGrid® is distributed in the United States of America, Canada and certain other countries by Tensar International Corporation (TIC). Inasmuch as SGTF and TIC have no control over installation design, installation workmanship, accessory materials, or conditions of application, SGTF and TIC do not warrant the performance or results of any installation or use of GlasGrid®. This warranty disclaimer includes all implied warranties, statutory or otherwise, including the warranty of merchantability and of fitness for a particular purpose. ©2007, Tensar International Corporation, Limited LLC, Inc. GG_IG_CG_2.07
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 for Macintosh Keywords : cg50, cg100, guidelines, preparation, fabric tractor, manual, placement, method, paving, road, surface, tack coat, issues, regulations, rules Create Date : 2007:03:16 11:19:14-04:00 Modify Date : 2007:06:19 16:36-04:00 Creator Tool : QuarkXPress: pictwpstops filter 1.0 Metadata Date : 2007:06:19 16:36-04:00 Document ID : uuid:b6140caf-d3d1-11db-86d5-000d9338cc52 Instance ID : uuid:b0b9b089-1ea4-11dc-8467-000d9338cc52 Marked : True Format : application/pdf Title : GlasGrid® System Installation Guide - CompuGrid Systems Description : GlasGrid® Pavement Reinforcement System Creator : Tensar International Corporation Subject : cg50, cg100, guidelines, preparation, fabric tractor, manual, placement, method, paving, road, surface, tack coat, issues, regulations, rules Page Count : 1 Author : Tensar International CorporationEXIF Metadata provided by EXIF.tools