SK 174020 00 01x Entech Nozzle Check Valve Iom
User Manual: Resource Library
Open the PDF directly: View PDF
.
Page Count: 1
| Download | |
| Open PDF In Browser | View PDF |
™ ENTECH RECOMMENDED INSTALLATION GUIDELINES FOR NOZZLE CHECK VALVES The Nozzle Check Valve (NCV) should be installed a minimum of 5 diameters and preferably 8 diameters downstream of a flow impediment, i.e. valve, reducer or bend etc, to ensure a good flow pattern at the entry to the NCV. If isolating valve is throttling, check valves should be installed as shown. The NCV should also be installed at least 3 diameters upstream of a bend or reducer to avoid choked flow conditions which can prevent the full opening of the check valve. The Nozzle Check Valve (NCV) may be installed on the upstream side of isolating valves. If the isolating valve is throttling, clearance as shown should be allowed to ensure full pressure recovery after the NCV. The NCV may be installed closer to the inlet of the isolating valve if it is full port and fully open. SK-174020-00-01 REV 01
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Creator : Microsoft Word - SK-174020-00-01.docx Producer : ScanSoft PDF Create! 6 Create Date : 2011:03:09 14:00:48Z Modify Date : 2011:03:09 14:00:48Z Author : wallacei Title : Microsoft Word - SK-174020-00-01.docx Page Count : 1 Page Mode : UseNoneEXIF Metadata provided by EXIF.tools