HE120A HE120B By Pass Drum Humidifier Honeywell He120 Product Data
User Manual: HE120B
Open the PDF directly: View PDF .
Page Count: 8
Download | ![]() |
Open PDF In Browser | View PDF |
HE120A,B By-Pass Drum Humidifier PRODUCT DATA FEATURES/BENEFITS • Can be installed in a furnace room without a drain. • Capable of humidifying a large area. • Small footprint, light weight and reversible components allow easy mounting on either warm air supply or return air duct of any forced air furnace. • Minimal amount of water and electricity needed for operation, saving the homeowner money. • Unique snap-lock fittings and reversible components allow quick installation and maintenance. • Interior components designed for easy clean up or replacement. • Durable thermoplastic cabinet resists rust, corrosion and warpage. APPLICATION The HE120A,B By-Pass Drum Humidifier uses the warm air furnace blower to provide humidification for the whole house. The HE120A,B works with virtually any Honeywell humidity control, but use the Honeywell Perfect Climate Comfort Center™ control for optimal performance. • Includes easy-to-use humidity control that mounts on the wall or duct for more installation flexibility. • Perfect Climate Comfort Center™ control can be installed to replace both the thermostat and humidity control for improved aesthetics and convenience. • Optional Automatic Flushing Timer can be used to reduce the frequency of maintenance. A drain is required if the timer is installed. Contents Application ........................................................................... Features/Benefits ................................................................ Specifications ...................................................................... Ordering Information ........................................................... Installation ........................................................................... Wiring .................................................................................. Operating the Humidifier ..................................................... Operation ............................................................................ Maintenance ........................................................................ Checkout Procedure ........................................................... Troubleshooting ................................................................... Replacement Parts .............................................................. ® U.S. Registered Trademark Copyright © 1998 Honeywell Inc. • All Rights Reserved 1 1 2 2 3 4 4 5 5 6 6 7 68-0190-3 HE120A,B BY-PASS DRUM HUMIDIFIER HE120 B Tradeline® By-Pass Drum Humidifier package includes: mounting template and hardware, self-piercing saddle valve, 24 Vac transformer and wire, by-pass tubing, summer shut-off damper, H1008A Automatic Humidity Control with HumidiCalc+™ Software. SPECIFICATIONS Capacity: At 120°F (49°C) plenum temperature and 0.20 static pressure drop across supply and return: 17 gallons per day (gpd) or 64 liters per day (lpd). Humidified Area: For precise sizing and product selection, use Honeywell’s HumidiCalc™ humidifier sizing software. If unavailable, refer to Table 1. House Description Loose Average Tight /1 -11 Sq ft Sq m Two 1,845 171 One 2,575 239 One-half 4,045 376 10 -7/ 11 Area (up to) Air Changes Per Hour 7) 29 6( Table 1. Size Of Area That Can Be Humidified. 12 -3/ 8( 8( 27 6) 31 4) 10 -1 (2 5/16 78 ) Drum Motor: 24 Vac, 3W, 1 rpm, bi-directional. Plenum Opening Dimensions (Height x Width): 6-5/8 in. x 8-1/2 in. (168 mm x 216 mm). By-Pass Duct Opening (Diameter): 6 in. (152 mm). M12254A Dimensions: Refer to Fig. 1. Fig. 1. HE120A,B Dimensions in in. (mm). Testing Standard: Air Conditioning and Refrigeration Institute: Standard 610. Accessories: C7089H Outdoor Temperature Suensor. H1008A Automatic Humidity Control with HumidiCalc+™ Software (software calculates dewpoint to prevent moisture condensation). H908A Convertible Humidity Control. HC40 Automatic Humidifier Flushing Timer. HumidiCalc™ Humidifier Sizing Software (software calculates required humidifier capacity for application). PC8900 Perfect Climate Comfort Center™ Control. Models: HE120A Tradeline® By-Pass Drum Humidifier package includes: mounting template and hardware, self-piercing saddle valve, 24 Vac transformer and wire, by-pass tubing, summer shut-off damper, H908A Convertible Humidity Control. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Home and Building Control Sales Office (check white pages of your phone directory). 2. Home and Building Control Customer Logistics Honeywell Inc., 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 (612) 951-1000 In Canada—Honeywell Limited/Honeywell Limitée, 155 Gordon Baker Road, North York, Ontario M2H 3N7. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 68-0190–3 2 HE120A,B BY-PASS DRUM HUMIDIFIER INSTALLATION COVER BEARING END OF DRUM SHAFT DRUM ASSEMBLY WARNING Electrocution and Chemical Hazard. Can cause death or blindness. Do not cut or drill into any air conditioning line or electrical accessory. CAUTION Freezing Water Hazard. Can result in water damage to property. Locate the humidifier where the ambient temperature is between 32°F and 180°F (0°C and 82°C). HUMIDIFIER HOUSING IMPORTANT To assure optimal product performance, be sure the template is level before marking location. WATER PAN 1. Determine the best location for the humidifier and draw a level line on the duct. See Fig. 2 for humidifier components. WATER VALVE OPENING Fig. 3. Humidifier components. 9. On the inside of the humidifier housing where the bypass tube connects, snap the bearing bracket into place with the U shape of the bracket pointing up. 10. Snap the motor plate into place on the opposite side of the humidifier housing. L TA ON M12252 RIZ HO NOTE: Be sure the motor coupling is positioned toward the top. OY HB HIG 11. Place the lead wires through the hole in the bottom of the motor cover and snap the cover in place. 12. Cut an opening for the 6 in. (152 mm) collar in the selected by-pass location. WN DO O FL NOTE: OY Be sure to install a duct damper for summer shutoff if there is air conditioning. WB LO 13. Install the 6 in. (152 mm) collar. 14. Use sheet metal screws to connect the by-pass tubing from the collar to the humidifier. 15. Seal the connections with duct tape. 16. Insert the drain fitting in the bottom of the humidifier housing. M13170 Fig. 2. Typical humidifier installation locations. NOTE: 2. Tape the template in position and trace around it. 3. Remove the template and carefully cut the rectangular opening. 4. Position the humidifier housing (See Fig. 3.) over the hole (be sure it is level) and mark the five mounting holes. 5. Set the cabinet aside and drill the five 7/64 in. (3 mm) mounting holes. 6. Start the three 3/4 in. (19 mm) sheet metal screws in the top holes. 7. Place the humidifier housing over the screws, level the housing and tighten the three screws. 8. Use two 1/2 in. (13 mm) screws to secure the humidifier housing at the bottom. Be sure the overflow tube is positioned toward the front and on the same side as the by-pass tubing. 17. Place the water pan in the humidifier housing so the overflow tube is above the previously installed drain fitting. NOTE: Be sure the tubing does not touch hot surfaces and sharp edges. 18. Attach a 3/8 in. (10 mm) ID tubing to the drain fitting and route downward to a suitable drain or catch basin. 19. Screw the float onto the float valve assembly. 3 68-0190–3 HE120A,B BY-PASS DRUM HUMIDIFIER 20. Attach the float valve to the humidifier housing on the same side as the motor. 21. Insert the valve hole plug in the double D hole on the opposite side of the valve. 22. Assemble the drum and humidifier pad. See Fig. 4. WIRING CAUTION Electrical Shock Hazard. Can shock or burn out equipment. • Disconnect power supply before installing or servicing. • To prevent premature transformer burnout on multispeed blower applications, do not wire the high voltage side of the transformer to the same power source that services the furnace blower. SQUEEZE SLIGHTLY TO INSTALL OPEN DRUM END All wiring must comply with applicable local codes, ordinances and regulations. 1. Mount the transformer in a convenient location. 2. Connect the wires to the 120V side of the transformer. 3. Wire the drum motor, transformer and humidity control. PAD TINNERMAN DRUM SHAFT METAL TABS CLOSED DRUM END Refer to the humidity control installation instructions for mounting and wiring information. M12243 Fig. 4. Assembling drum and humidifier pad. OPERATING THE HUMIDIFIER 23. Insert the drum assembly into the motor coupling end and snap into the bearing end. 24. Install the saddle valve (using the instructions on the saddle valve bag) on the nearest cold water pipe. 25. Connect the copper tubing and route to the humidifier. 26. Connect the copper tubing to the humidifier valve and finger tighten. 27. Use a wrench to turn the nut one and one-half turns more. 28. Turn the water on at the saddle valve and adjust the water level to 1-3/8 in. deep. NOTE: The HE120A humidifier is controlled by the H908A Humidity Control that is installed either on an interior wall in the living area or on the return air duct. Choose the M13155 H908A setting using the combination relative humidity/outdoor temperature setting scale on your humidity control. Match the dial setting to the outdoor temperature for optimizing the humidity level while reducing the moisture condensation on your windows. Table 2 can also be used to adjust the humidity control to the recommended setting. Turn the valve adjustment screw (located on the water valve inside the humidifier) clockwise to lower and counterclockwise to raise. Table 2. Recommended Humidity Control Settings. At Outside Temperature Recommended Setting At Outside Temperature Recommended Setting -20°F (-29°C) 15 +10°F (-12°C) 30 -10°F (-23°C) 20 +20°F (-7°C) 35 0°F (-18°C) 25 Above 20°F (-7°C) 40 NOTE: As the outside temperature drops, the recommended setting is lowered to accommodate the effects of dewpoint. These settings should reduce the accumulation of moisture and ice on the windows and in other areas of the house. Some indoor activities such as cooking, showering and clothes drying can cause excessive levels of humidity and start the accumulation of moisture on the windows. NOTE: Your Honeywell HE120B Humidifier is controlled by the Honeywell H1008 Automatic Humidity Control with HumidiCalc+ Software. The automatic humidity control is mounted in the return air duct where it can be exposed to the air stream of the return air. The HumidiCalc+ Software inside your automatic humidity control is designed to automatically adjust If this condition persists for more than a few hours, set the humidity control to the lowest setting to turn off the humidifier. If the condition does not improve, ventilate your home to remove the moisture. 68-0190–3 4 H1008A M12817 HE120A,B BY-PASS DRUM HUMIDIFIER the humidity level based on indoor temperature and humidity, inferred or measured outdoor temperature, and the setting of the frost factor dial. The frost factor allows for variations in furnace size, window insulation and average daily climate temperature. Every 1 to 3 Months (Depending on Water Quality) CAUTION The Automatic Humidity Control with HumidiCalc+ Software requires an initial adjustment period. Set the frost factor dial on 5 and use Table 3 to adjust the frost factor—only one setting at a time—increasing the dial setting if you feel you need more humidity, or reducing the setting if you see moisture on the inside of your windows. For more precise humidity adjustment, set the frost factor between dial settings. Allow two days for the humidity level to subside before making further adjustments. Once you have tuned in the proper setting, you should never have to adjust it again. HumidiCalc+ Software takes over and makes any future adjustments caused by varying outdoor temperatures, thus reducing moisture build-up on windows while maintaining the optimal humidity level. Voltage Hazard. Can cause electrical shock and equipment damage. Disconnect power supply before installing or servicing. IMPORTANT Never oil any part of the humidifier. Use the following procedure to clean the humidifier: 1. Disconnect the power and turn off the humidifier water supply. 2. Remove the humidifier cover by lifting up the bottom of the cover. See Fig. 5. BEARING END OF DRUM SHAFT COVER Table 3. Recommended Frost Factor Settings. Humidity Level DRUM ASSEMBLY Recommended Adjustment Insufficient humidity Increase the frost factor dial by one setting Condensation on windows Decrease the frost factor dial by one setting OPERATION The HE120A,B humidifier uses the principle that vapor (evaporated water) is created when warm air blows over a water soaked area. As the vapor circulates, the relative humidity rises. HUMIDIFIER HOUSING WATER PAN The humidity control monitors the relative humidity and activates the humidifier accordingly. The humidifier has a water supply that disburses water over a humidifier pad. The warm dry air from the furnace passes over the humidifier pad and picks up the moist air to circulate it through the house. WATER VALVE OPENING M12252 Fig. 5. Location of humidifier parts. Humidified air feels warmer and more comfortable so the homeowner may be able to lower the thermostat heating setpoint and save money on heating fuel bills. The end result is that the humidifier gives the homeowner a comfortable environment that is also energy efficient. 3. Lift up the drum shaft from the bearing end and slide it out of the motor coupling to remove the drum assembly. NOTE: You will encounter some resistance and hear an audible click when removing the drum shaft. 4. Remove the drum from the assembly. 5. Grasp the rubber valve seat between thumb and forefinger and lift it upward to remove the valve seat from the valve. (The seat is located inside the humidifier housing at the water valve opening.) 6. Raise up the float and remove the water pan. 7. Refer to Fig. 6 to disassemble the drum. 8. Clean all humidifier parts in a 50 percent solution of vinegar (or a humidifier cleaner) and water. Soak overnight to remove stubborn deposits. MAINTENANCE A regular maintenance program prolongs the life of the humidifier and provides a more comfortable environment. Frequency of cleaning depends on the condition of the water. You can use either hard or soft water in the humidifier, but hard water mineral deposits are more difficult to clean than soft water deposits. NOTE: 5 Replace humidifier pad yearly. The actual frequency depends on the quality of the water used. 68-0190–3 HE120A,B BY-PASS DRUM HUMIDIFIER 9. After the humidifier components are clean, reassemble the humidifier by reversing the order of steps 1 through 7. NOTE: CHECKOUT PROCEDURE After winter startup or maintenance, use the following procedure to check the humidifier operation: To be sure that the drum shaft is completely seated, listen for the click. 1. Turn on the humidifier power and water supply. 10. Verify the humidifier operation by following the steps in the Checkout Procedure section. 2. Check the water level in the humidifier water pan; water level setting should be 1-3/8 in. deep. Turn the valve adjustment screw (located on the water valve inside the humidifier) clockwise to lower the water level and counterclockwise to raise it. End of Humidification Season The humidifier should be cleaned and shut off at the end of the heating season. Use the Every 1 to 3 Months section, steps 1 through 9, to shut down for the season. 3. Turn the H908A Convertible Humidity Control to the highest setting or the H1008A Automatic Humidity Control to the Test position, and set the thermostat to 10°F (6°C) above the room temperature. IMPORTANT Be sure the humidifier power is off and the humidifier is empty. Vacation NOTE: When you leave on vacation, turn off the humidifier water supply and your humidity control. When you return, turn on the humidifier water supply and reset your humidity control. The H1008A Automatic Humidity Control stays in the test mode for thirty minutes. After thirty minutes, the control automatically resets to the maximum frost factor setting. If system checkout has not been completed in thirty minutes, the test mode can be extended by turning the dial back to one of the dial settings and then returning it to the test mode. 4. Check that the humidifier pad is rotating. 5. Reset the thermostat and the Convertible Humidity Control to a comfortable setting, or the Automatic Humidity Control to the desired frost factor setting, for automatic operation. SQUEEZE SLIGHTLY TO INSTALL OPEN DRUM END PAD TINNERMAN DRUM SHAFT METAL TABS CLOSED DRUM END M12243 Fig. 6. Drum assembly parts. TROUBLESHOOTING Refer to Table 4 for troubleshooting procedures. Table 4. Troubleshooting Procedures. Problem Low humidity High humidity 68-0190–3 What To Look For What To Do Furnace blower not operating. • • • • • Reset circuit breaker or check for blown fuse. Check that the furnace power is on. Check all external wiring connections. Check the humidity control setting. Call a professional heating contractor. Rapid air changes. Drafts (cold air is dry and is an added load to the humidifier). • • • • Keep doors and windows closed. Close fireplace damper when not in use. Keep exhaust fan running time to a minimum. Seal around doors and windows. Condensation on walls. • Turn off humidity control and water until condensation is completely evaporated. Heavy condensation on windows. • Turn humidity control down low enough to eliminate condensation caused by moisture from bathing, mopping, cooking, etc. If moisture persists, more ventilation is needed. 6 HE120A,B BY-PASS DRUM HUMIDIFIER REPLACEMENT PARTS Refer to Fig. 7 and Table 5 when ordering replacement parts. 8 10 9 9 9 9 13 12 14 11 3 1 4 5 7 6 2 M12239A Fig. 7. Exploded view of humidifier parts. 7 68-0190–3 HE120A,B BY-PASS DRUM HUMIDIFIER Table 5. List Of Replacement Parts For HE120 Humidifier. Exploded View Number 1 Description Cover Assembly HE120 Part Number 32000131-001 2 24 Vac motor 32000132-001 3 Humidifier housing 32000133-001 4 Water pan 32000134-001 5 Float for valve 32000135-001 6 Float valve 32000136-001 7 Valve seat 32000137-001 8 Saddle valve assembly 32001616-001 9 Drum assembly 32000141-001 10 Humidifier pad (includes clips) 32000146-001 11 Transformer (10 VA) 32001652-001 12 Bearing bracket 32000147-001 13 Convertible Humidity Control H908A1003 14 Automatic Humidity Control H1008A1008 — Current Sensing Relay 32001754-001 Home and Building Control Honeywell Inc. Honeywell Plaza P.O. Box 524 Minneapolis MN 55408-0524 Home and Building Control Honeywell Limited-Honeywell Limitée 155 Gordon Baker Road North York, Ontario M2H 3N7 Honeywell Latin American Region 480 Sawgrass Corporate Parkway Suite 200 Sunrise FL 33325 Honeywell Europe S.A. 3 Avenue du Bourget 1140 Brussels Belgium 68-0190—3 J.S. Rev. 6-98 68-0190–3 Printed in U.S.A. on recycled paper containing at least 10% post-consumer 8 paper fibers. Honeywell Asia Pacific Inc. Room 3213-3225 Sun Hung Kai Centre No. 30 Harbour Road Wanchai Hong Kong www.honeywell.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Extract, Print high-res XMP Toolkit : 3.1-702 Create Date : 1998:06:05 07:33:17Z Creator Tool : Adobe PageMaker 6.5 Modify Date : 2007:12:13 18:31:01-05:00 Metadata Date : 2007:12:13 18:31:01-05:00 Format : application/pdf Description : ByPass Drum Humidifier Creator : Honeywell - Bel-Aire ElectronicAirCleaners.com Title : HE120A HE120B By-Pass Drum Humidifier Subject : White-Rodgers Whole House Humidifier HDT2600 Series, Skuttle Model 190 Keywords : White-Rodgers Whole House Humidifier HDT2600 Series..Skuttle Model 190 Producer : Acrobat Distiller 3.01 for Power Macintosh Document ID : uuid:b642feb9-93d6-417b-b66a-50794a8f9f5b Instance ID : uuid:0bcb9f9c-382a-41a7-8dff-91c55f466d64 Has XFA : No Page Count : 8 Author : Honeywell - Bel-Aire ElectronicAirCleaners.comEXIF Metadata provided by EXIF.tools