KD3000PV3.0 Kd3005p User Manual
User Manual:
Open the PDF directly: View PDF .
Page Count: 6
Download | |
Open PDF In Browser | View PDF |
Programmable DC Power Supply KD3000-6000 Series User Manual SHENZHEN KORAD TECHNOLOGY CO. LTD. Address:F3, Building A4, District B, Songbai Industrial Park, Guangming New District, Shenzhen, 518106, P.R.China. Tel: 86-755-61535026 Fax: 86-755-61535025 E-mail: adam@koradtechnology.com www.koradtechnology.com www.korad.com.cn User Manual KD3000/6000- Series User Manual Main Features Low noise Cooling fan controlled by heatsink temperature Constant voltage / constant Digital panel control 4 digits display Software calibration Over Current Protection Button lock function USB/RS232 for remote control 1 KD3000/6000- Series User Manual 7. OUTDescription:Turns on or off the output. Boolean:0 OFF,1 ON Example: OUT1 Turns on the output 8. STATUS? Description:Returns the POWER SUPPLY status. Contents 8 bits in the following format Bit Item Description 0 CH1 0=CC mode, 1=CV mode 1,2,3,4,5 N/A 6 Output 0=Off, 1=On 7 N/AN/A 9. *IDN? Description:Returns the KA3005P identification. Example *IDN? Contents KORAD KD3005P V2.0 (Manufacturer, model name,). 10. RCL Description:Recalls a panel setting. NR1 1 5: Memory number 1 to 5 Example RCL1 Recalls the panel setting stored in memory number 1 11. SAV Description:Stores the panel setting. NR1 1 5: Memory number 1 to 5 Example : SAV1 Stores the panel setting in memory number 1 12. OCP Description:Over current Example :OCP1 OCP ON KD3000/6000- Series User Manual SAFETY INSTRUCTION Safety Guidelines •Do not block or obstruct the cooling fan vent opening. •Avoid severe impacts or rough handling that leads to damage. •Do not discharge static electricity . •Do not disassemble unless you are qualified as servi ce perso nnel. AC INPUT ! •AC Inut Voltage: 110V / 120V / 220V / 230V , 50 / 60 Hz •Connect the protective grounding conductor of the AC power cord to an earth ground, to avoid electrical shock. •Location: Indoor, no direct sunlight, dust free, almost non-conductive pollution (note below) Operation • Environment Relative Humidity: < 80% •Altitude: < 2000m • •Temperature: 32–104°F Storage environment FUSE ! •Location: Indoor •Relative Humidity: < 70% •Temperature:-10-70℃ Mode l KD 300 3 110/ 120 VV T4A/ 250 V 220 /230 V T2A/ 250 V KD 300 5 KD 600 3 T5A/ 25 0V T5A/ 25 0V T3A/ 250 V T3A/ 250 V •To ensure fire protection, replace the fuse only with the specified type and rating. •Disconnect the power cord before fuse replacement. •Make sure the cause of fuse blowout is fixed before fuse replacement. 9 2 KD3000/6000- Series User Manual KA Series Remote Control Syntax V2.0 KD3005D DIGITAL_CONTROL DC POWER SUPPLY OCP Over Current Protection Active C .C Constant Current Mode C .V Constant Voltage Mode LO CK Panel LOCK Indicator V Display of voltage & current value A VOLTAGE Adjustment Knob for Voltage CURRENT Push/Hold Push/Hold LOCK / UNLOCK OCP ON/OFF PUSH PUSH FI NE /CO AR SE FI NE /CO AR SE POWER - + Power ON / OFF Button Adjustment Knob for Current GND Output TerminalS FNSZ1057-00-00 S/N NO:011062300000000-0000 Fan WARNI NG VOLTAGE RATING: AC 220V FUSE RATING: 2A / 250V TO AVOID ELECTRIC SHOCK, THE POWER CORD PROTECTIVE GROUNDING CONDUCTOR MUST BE CONNECTED TO GROUND. FOR CONTINUED FIRE PROTECTION, REPLACE FUSE WITH 250V FUSE OF THE SPECIFIED TYPE AND RATING.NO OPERATION SERVICEABLE COMPONENTS INSIDE Label on Vol tage & Fuse DO NOT REMOVE COVERS; REFER SERVICING TO QUALIFIED PERSONNEL. Power Socket USB Interface Rs232 Interface DISPLAY Voltage level Current level V A Voltmeter displays the setup value of output voltage . Displays the setup value of output current . 3 KD3000/6000- Series User Manual Command format :VSET : 1. VSET: command header 2. X: output channel 3. : separator 4. NR2: parameter Command Details: 1. ISET : Description: Sets the output current. Example:ISET1:2.225 Response time 50ms Sets the CH1 output current to 2.225A 2. ISET ? Description: Returns the output current setting. Example: ISET1? Returns the CH1 output current setting. 3. VSET : Description:Sets the output voltage. Example VSET1:20.50 Sets the CH1 voltage to 20.50V 4. VSET ? Description:Returns the output voltage setting. Example VSET1? Returns the CH1 voltage setting 5. IOUT ? Description:Returns the actual output current. Example IOUT1? Returns the CH1 output current 6. VOUT ? Description:Returns the actual output voltage. Example VOUT1? Returns the CH1 output voltage 8 KD3000/6000- Series User Manual KD3000/6000- Series User Manual REMOTE CONTROL COM setting Condition Indicators - LED Panel Lights Set up the COM port inside the PC according to the following list. OCP Over Current Protection indicator. When the power supply is in OCP mode this light is on. C .C C.C indicates constant current. When the power supply is in constant current mode, this light is on. C .V C.V indicates constant voltage. When the power supply is in constant voltage mode, this light is on. LOC K Panel LOCK Indicator • Baud rate: 9600 • Parity bit: None • Data bit: 8 • Stop bit: 1 • Data flow control: None Voltage and Current Adjustment Knob Operation There are 3 adjustment modes for the voltage and current levels, that is, Mode 1 and Mode 2. Mode 1: Before setting, push the knobs to adjust the voltage and current levels. Mode 2: adjust directly, no need to push the knobs. And these 2 modes can be shifted by pushing the voltage adjustment knob and the current adjustment knob at the same time and holding for 2 seconds. Mode 3: remote control mode (programmable control mode). RS232 Interface Definition 2 3 2 3 5 5 Mode1 LOCK Adjustment Mode VOLTAGE Push/Hold LOCK / UNLOCK PC KD3005P DC POWER SUPPLY PUSH FINE/COARSE CURRENT Functionality Run this query command via the terminal check application such as MTTTY (Multi-threaded TTY). *DIN? This should return the identification information: Manufacturer, model name, software version. KORAD KD3003P Vx.xx 7 Push/Hold OCP ON/OFF PUSH FINE/COARSE Voltage Adjustment Knob: Push the voltage adjustment knob and then the voltage meter will flicker, when voltage output can be changed by adjusting the knob. T hen the resolution of the knob rotation can be changed. Push it to change the resolution of voltage adjustment; Current Adjustment Knob: Push the voltage adjustment knob and then the voltage meter will flicker, when voltage output can be changed by adjusting the knob. And push the knob again when the meter flikers, then the resolution of the knob rotation can be changed. Will be closed. 4 KD3000/6000- Series User Manual KD3000/6000- Series User Manual Specifications Mode 2 Continuous Adjustment Mode In mode 2,rotate the adjustment knobs to adjust the voltage and current values. The default of the voltage initial settings is 1v while that of the current is 100mA. The voltage and current levels can be changed by pushing the knobs. Note: The specifications below are tested under the conditions of temperation 25℃+-5℃ and the warm-up for 20 minutes. Mode ls Voltage Current KD300 3P KD300 5P KD600 3P 0-30V 0-5A 0-60V 0-3A Voltage ≤0.01 %+2m v Current ≤0.1%+5m A Line Regulation ≤0.01 %+2m v ≤0.1%+10m A ≤0.01 %+2m v ≤0.1%+5m A Voltage ≤0.01 %+3m v Current ≤0.1%+3m A Setup Resolution ≤0.01 %+3m v ≤0.1%+3m A ≤0.01 %+3m v ≤0.1%+3m A 0-30V 0-3A Load Regulation Operation of Over Current Protection CURRENT press and hold for 3 seconds to start OCP mode, where the output will be cut off when the output current reaches the set value. In the OCP mode, rotate this knob to recover the output. Press and hold for 3 seconds again and then the OCP functi on Push/Hold OCP ON/OFF PUSH FINE/COARSE Voltage 10m V 1 mA Setup Accuracy(25℃+-5℃) 10m V 1 mA Current Mode 3 Remote Control Mode Push and hold the VOLTAGE knob for 3 seconds to lock the VOLTAGE and CURRENT adjustment knobs. Then the output of the power supply will be off. At this time, the CURRENT adjustment knob becomes the output knob; push the CURRENT knob and then the output of the power supply will be ON and OFF accordingly. Push and hold the VOLTAGE knob again for 3 seconds and the VOLTAGE and CURRENT adjustment knobs will be unlocked . VOLTAGE Push/Hold LOCK / UNLOCK PUSH FINE/COARSE Power Switch and Output Terminals POWER On / Off main power. ≤0. 5%+20m V ≤0. 5%+30m V ≤0. 5%+10m A ≤0. 5%+5m A ≤1 m V rms Current ≤3 mArms Temp. Coefficient ≤2 m V rms ≤3 mArms ≤1 m V rms ≤3 mArms ≤150 ppm ≤150 ppm Read Back Resolution ≤15 0ppm ≤150 ppm ≤150 ppm ≤150 ppm 10 m V 1 mA 10 m V 1 mA Voltage ≤0. 5%+20m V Current ≤0. 5%+5m A Ripple(20-20M) Voltage Voltage Current 10 m V 1 mA Read Back Temp. Coefficient Voltage Current Voltage Current + outputs voltage and current. Connects the ground (earth ) terminal. 5 10m V 1 mA ≤150 ppm ≤150 ppm ≤150 ppm ≤150 ppm Accessories User manual *1, Power cord*1 Weight and Dimension KD3003,KD3005,KD6003:110mm(W)*156mm(H)*260(D) KD3003x4Kg,KD3005x4.8Kg 6 ≤150 ppm ≤15 0 ppm
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 6 Create Date : D:20141007092027 Modify Date : D:20141007092027 Producer : Corel PDF Engine Version 1.0.0.458 Creator : CorelDRAW 版本 12.0 Title : KD3000PV3.0EXIF Metadata provided by EXIF.tools