Ledeen Valve Control Board For Pneumatic Actuators Brochure

User Manual: Resource Library

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadLedeen-valve-control-board-for-pneumatic-actuators-brochure
Open PDF In BrowserView PDF
LEDEEN Valve Control Board for
Pneumatic Actuators

Since 1946, Cameron’s LEDEEN® brand has been providing

valves in oil and gas applications. The LEDEEN VCB for

engineering and technical expertise for valve actuators and

pneumatic actuators is capable of a variety of operations,

control systems. Continuing this legacy, Cameron has

including increasing flow capacities and suite operation

designed a standard valve control board (VCB) for

requests on stroking time on a wide range of actuators.

pneumatic actuators.

This innovative product is highly customizable, allowing for

Designed using in-field, real world problem solving and

a flexible layout with a variety of options, including stop,

keeping serviceability in mind, this VCB offers one of the

check, relief, and flow regulating valves. It offers one of the

highest levels of reliability and safety on the market today.

easiest retrofits in the industry, maintaining brand-neutrality

The system has been developed to provide a turnkey

and certification quality.

control panel for the most common logics used for on/off

Easy to Maintain
Reliable and Safe
Quick Delivery Options
High Flexibility and Customization

Various Control Logics

Standard Layout

2

TECHNICAL DATA
Panel: Control system components are mounted on a SS 316 panel complete with a sunshade
Dimensions: Panel has a very compact design – overall dimensions are 18” x 16” x 10” (450 mm x 400 mm x
250 mm) for fail-open and fail-closed schematics for spring return actuators and 22” x 18” x 10” (550 mm x
450 mm x 250 mm) for stay put schematics for double acting actuators.
Mounting: Different assembling options are available:
• On board (panel mounted directly to LEDEEN actuator)
• On 2” pole (mounting kit separately delivered on request)
• Wall mounted (mounting kit separately delivered on request)
Tubing and Fittings:
• Tubing: SS 316L – imperial size (metric available on request)
• Fittings: SS 316 double ferrule type (Swagelok)
Ambient Temperature Range:
• -4º F to 122º F (-20º C to 50º C)
Schematics: For detailed description of available schematic logics please refer to pages 4 and 5

3

FAIL-OPEN OR FAIL-CLOSED ON SUPPLY FAILURE
Spring Return Actuator Configurations
The schematic diagram is shown
without pneumatic and electric power

36

86*

50

30

27
86*
32*

13

28

8 – Filter
12 – Stop valve (*)
13 – Pressure gauge
23 – Check valve (*)
27 – Solenoid valve
28 – Pressure regulator
30 – Junction box (built in)
32 – Safety valve (*)
36 – Quick exhaust
50 – Pneumatic piloted valve
(based on schematics)
86 – Flow control valve (*)

8

Tank Port
23*

12*

* Optional on request

Supply Line

VCB complements a complete range of actuators. Options available in VCB to increase flow performance upon request.
Inlet
Size

Pilot Valve

S1

1/4”

–

–

VA0, VA1

S2

1/4”

–

X

GS2, GS6, SY8

S3

1/2”

X

–

SY10, SY13

S4

1/2”

X

X

SY16

S5

1/2”

X

X

SY20

Schematic

Fail
(Spring Return)

4

Quick Exhaust

Recommended for LEDEEN Series:

STAY PUT ON SUPPLY FAILURE
Double Acting Actuator Configurations
The schematic diagram is shown
without pneumatic and electric power

50

27A

27B
86*

86*

13

32*

30A

28

8 – Filter
12 – Stop valve (*)
13 – Pressure gauge
23 – Check valve (*)
27 – Solenoid valve
28 – Pressure regulator
30 – Junction box (built in)
32 – Safety valve (*)
50 – Pneumatic piloted valve
(based on schematics)
86 – Flow control valve (*)

30B

8

Tank Port
23*

12*

* Optional on request

Supply Line

VCB complements a complete range of actuators. Options available in VCB to increase flow performance upon request.
Schematic
Stay Put
(Double Acting)

Inlet Size

Pilot Valve

Recommended for
LEDEEN Series:

D1

1/4”

–

GS2, GS6, SY8, SY10

D2

1/4”

X

SY13, SY16, SY20

5

FUNCTIONAL ELEMENTS DESCRIPTION

13
28

23*

8
12*

12 – Stop valve (*)
23 – Check valve (*)

8 – Filter
13 – Pressure gauge
28 – Pressure regulator

* Optional on request

Air Supply:

Air Treatment:

STD – straight inlet port for supply line (1/2” NPT)
Options – stop valve – check valve and additional
tank port (1/2” NPT)

STD – filter regulator: aluminum body/≤ 25 µm mesh –
pressure gauge: Ø 50 mm/dual scale bar/psi
Options – filter regulator: stainless steel body/alternative brands

50

27

50

27A

30

27B

30B

30A

27 – Solenoid valve
30 – Junction box (built in)
50 – P
 neumatic piloted valve
(based on schematics)

Air Power Logic:
STD – solenoid valve: SS316 body/aluminium enclosure coil /24VDC /Atex-IECEx Ex-d
certified – pilot valve (based on stroking time requirement)
Options – solenoid valve: SS316 enclosure coil /110VAC/manual reset / alternative brands

Optional Accessories

Flow Regulation Valve
Inlet/exhaust flow modulation
to set stroking times

6

Safety Valve

Quick Exhaust

Electric Positioner

Over-pressure relief to prevent
either valve or actuator damage

Exhaust flow enhancement
to match stroking time
requirement

Valve position monitoring
and partial-stroke test (PST)
functionality

CODING
1oo1 architecture

Control System Logic
and Certification

1oo1

Schematic diagram
(refer to pages 4-5)

0

0 – Without PST feature
1 – C/ W PST feature

Al

AI – Atex/IECEx

S

S – Stainless steel body
A – Aluminum body

Solenoid Valve

S

Filter Regulator

S – LEDEEN STD
N – Norgren
V – Versa
A – Asco

S1

A

S – LEDEEN STD
N – Norgren™
A – Asco™
M – Maxseal™
V – Versa™

A

A – Aluminum coil enclosure
S – SS coil enclosure
24D – 24V DC
115A – 115V AC

24D

0 – Automatic reset
1 – Manual reset

0

0 – No acc
C – Check valve (c /w tank port)
S – Stop valve
B – Check + stop valve

0 – No relief
P – PED
U – ASME UV-STAMPED
C – CRN
I – Tubing imperial size
M – Tubing metric size

0

0

0

Accessories

0 – No flow reg.
I – Inlet flow reg.
E – Exhaust flow reg.
B – Both reg.

M

Although checked for accuracy at the time of printing, Cameron’s commitment of continuous improvement and
innovation may have resulted in product enhancements or modifications not currently shown.

7

3250 Briarpark Drive, Suite 300
Houston, TX 77042
USA
Tel 1 281 499 8511
Via Gandini, 4
27058 Voghera
Italy
Tel 39 0383 343311
Learn more about LEDEEN actuators at:
LEDEEN@c-a-m.com
www.c-a-m.com/LEDEEN
ValveAutomation@c-a-m.com
www.c-a-m.com/ValveAutomation

XLCL
L CEE
ELELN
AX
TE
EN
CCE
ENL
TA
M

ETFYET
HSASFA
SYEC
LTLHT
AU
AA
HEE

VDIREONNVM
N
AN
IROE
TYE
NN
NRID

E

CCA
N
AM
ON
MEER
RO

HSE Policy Statement
At Cameron, we are committed ethically, financially and personally to a
working environment where no one gets hurt and nothing gets harmed.

H

©2014 Cameron | LEDEEN is a registered trademark of Cameron. All others are registered trademarks or trademarks of their respective owners. | 10/14 AD01494V



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Create Date                     : 2014:11:04 10:22:33-06:00
Creator                         : Adobe InDesign CC 2014 (Macintosh)
Modify Date                     : 2014:11:17 10:18:13-06:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Instance ID                     : uuid:c0f65761-9649-4797-9ee0-53aa4effc005
Original Document ID            : adobe:docid:indd:41f17109-c261-11de-99a7-861d1bf3a84c
Document ID                     : xmp.id:2b177b51-d8ff-4424-bc80-834ee595c379
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:2ba9aa83-2532-48be-99cc-ca6e9feb32bd
Derived From Document ID        : xmp.did:eaa5f628-45a4-4077-8106-66020ef4a336
Derived From Original Document ID: adobe:docid:indd:41f17109-c261-11de-99a7-861d1bf3a84c
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2014 (Macintosh)
History Changed                 : /
History When                    : 2014:11:04 10:22:33-06:00
Metadata Date                   : 2014:11:17 10:18:13-06:00
Creator Tool                    : Adobe InDesign CC 2014 (Macintosh)
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Count                      : 8
EXIF Metadata provided by EXIF.tools

Navigation menu