Components Diagram ...............................................3
Preparation....................................................................4
Precautions..............................................................4 - 5
Specifications ...............................................................5
Operations ............................................................ 6 - 10
Calibration .................................................................. 10
Accessories ................................................................. 10
Service & Maintenance ..................................10 - 11
Certifications & Classifications ....................11 - 12
Warranty ..............................................................12 - 13
Disclaimers .........................................................13 - 15

Components Diagram
Back View

Front View
1

1

2

2

3

The LifeGuard is intended to measure alcohol in
human breath. Measurements obtained from this
device are used in the diagnosis of alcohol intoxication. The LifeGuard is intended to be used by the
general adult population and by qualified personnel, such as physicians, nurses, and technicians. The
LifeGuard product is intended to be used by adults
(age 21 and over) in measuring alcohol intoxication
in themselves or others, and is intended to be used
in both home (over the counter) & clinical settings.
It is very important to have the instrument calibrated as recommended in this operators manual
on page 10. Failure to do so may result in readings
that are inaccurate.

4
5
6
7
1. Disposable (slip-on)
Mouthpiece
2. Permanent (fold-away)
Mouthpiece
3. Display Screen

4. Power Button
5. Execute Button
6. Battery Cover
7. Wrist Strap Loop

3

Preparation
Battery Installation
The LifeGuard is designed to operate from a common 9 volt (EN22 / 9V) alkaline battery. Remove
the battery door by pressing down slightly and
sliding the door toward the back of the unit. Install
the battery following the polarity markings on
the inside of the battery housing. To close, apply a
small amount of pressure on the battery while sliding the battery door toward the front of the
instrument.

Precautions

7. We recommend storing the LifeGuard in
temperatures between 32o - 122oF (0o - 50o C).
8. No user serviceable parts inside. To be serviced
only by an authorized LifeGuard technician.
9. If instrument will not be used for more than 6
months remove battery to avoid damage to the
instrument caused by leaking battery acid.

Specifications
Sensor

+ .005 BAC up to .100 BAC +5% above

Accuracy

1. DO NOT DRINK AND DRIVE! - It is strongly
recommended that no vehicle or machinery be
operated after alcohol consumption. Even small
quantities of alcohol can cause impairment. The
LifeGuard product should not be used as a tool
to determine if it is safe for the user to operate
machinery or a motor vehicle.
2. Wait at least 15 minutes after drinking, smoking
or inserting anything in your mouth before
taking a breath test.
3. The LifeGuard product is intended to be used by
adults (age 21 and over) in measuring alcohol
intoxication in themselves or others.
4. The LifeGuard is not to be used in potentially
explosive environments such as an oxygen tent.
5. Do not blow smoke into the mouthpiece as it
may damage the sensor.
6. Replace the battery when the low battery icon
is displayed.

4

Electrochemical Fuel Cell
.100 BAC
+0.02mg/l up to 0.47mg/l +5% above

0.47mg/l
Units of Measure

BAC (Breath Alcohol Content)

Power

9V alkaline battery

Battery Life

Approx. 300 tests

Detection Range

000 - .400 BAC (0.00-1.90mg/l)

Operating Temp.

32o F - 122o F (0o C - 50o C)

Display

High Resolution Graphic Display

Size

1.25" x 2.5" x 5" (31.7 x 63.5 x 127mm)

Weight w/Battery

5oz (142 grams)

Test Mode

Automatic

Warranty

1 year limited warranty

This device has been tested following NHTSA/DOT
procedures. In that testing protocol, the accuracy of
this device was established at Blood Alcohol Concentrations of 0.008 and 0.032. Lifeloc performs & validates
additional testing at concentrations of 000 - .400 BAC.

5

Operations
User Prompts

Wait 15
Minutes

No
Drinking

No
Eating

No
Smoking

Cause & Course of Action
Ready - Begin blowing into the unit.

xx/xx/xxxx

1
Blow Longer

2
Blow Longer

4

Low Battery - The battery needs to be
replaced.
Wait - The fuel cell is not yet ready for a
test.
Temperature - The internal temperature
of the instrument is outside of its testing
range.
Calibration Due - Due date appears when
turned on within 35 days of requiring calibration & when calibration is overdue.
Insufficient breath - Subject blew less
than 1 liter of breath. Try again and blow
steadily for at least 4 seconds.
Insufficient breath - Subject didn’t blow
long enough. Try again and blow steadily
for at least 4 seconds.
Subject is inhaling. Try Again.

Do Not Inhale

5
Interference

6
Mouth Alcohol

7
Condensation

9-12

Interference - High levels of electronic
interference are detected. Try the test in a
different location.
Excessive Alcohol - Detector sensed
alcohol levels above .400 BAC.
Excessive Condensation - Let the unit rest
for 30 minutes.

Needs Service

Self-test error - Instrument may need
servicing. Contact LifeGuard Tech Support.

Over Range

Over Range - Detector sensed alcohol
levels above .400 BAC

>0.4

6

1. Turn-on the LifeGuard by momentarily
pressing the power button. The instrument
will initiate a self-test and then display the
ready icon.
2. For maximum convenience, the LifeGuard uses
a dual-mode mouthpiece design that can be
operated in two ways according to your
testing circumstances.
2a. Permanent (fold-away) Mouthpiece
The permanent (fold-away) mouthpiece conveniently folds into the LifeGuard when not in
use. The fold-away mouthpiece is intended for
self-testing or repeated testing of the same
subject. When not in use it folds away until
you need it.
The Permanent (fold-away) mouthpiece is
designed to remain attached to the Lifeguard
under normal use; however it can be removed
for cleaning. Do not discard the permanent
(fold-away) mouthpiece. It is an integral part
of the Lifeguard and is used for both personal
testing and in the testing of others.
If the fold-away mouthpiece becomes contaminated with food, dirt or other foreign
matter it should be cleaned to prevent contamination of the internal breath path and fuel

7

cell. Do not immerse the Lifeguard unit
in water. To clean the permanent (fold-away)
mouthpiece, tilt the mouthpiece to a 45o
angle towards the closed position and gently
pull the mouthpiece up and away from the
unit, as shown in the diagram below. Do not
force or bend the mouthpiece over the edge
of the Lifeguard to remove.

Clean the permanent (fold-away) mouthpiece
with warm water and dish detergent as you
would with eating utensils. Allow to thoroughly dry and re-attach to the Lifeguard.
If the mouthpiece becomes damaged or lost,
additional permanent (fold-away) mouth
pieces can be ordered from
www.lifeguardbreathtester.com or your dealer.
2b. Disposable (slip-on) Mouthpiece
Disposable (slip-on) mouthpieces are for one
time use. Each mouthpiece is individually factory sealed until the moment you need it. Fold
out the permanent (fold-away) mouthpiece
and attach a disposable (slip-on) mouthpiece
over the permanent mouthpiece (see

components diagram on page 3). You are now
ready to take a test.
3. The subject being tested should not eat, drink,
smoke or put anything in their mouth for 15
minutes prior to taking a breath alcohol test.
Failure to comply with this instruction may
result in inaccurate readings.
4. Instruct the subject to take a deep breath and
blow firmly and steadily into the LifeGuard for
a minimum of four (4) seconds. The instrument
will provide a steady tone if the subject is
blowing correctly.
If the subject blows for less than 4 seconds
the LifeGuard will display the message to
“Blow Longer”. Instruct the subject to blow
steadily for at least 4 seconds.
While the subject is blowing, the LifeGuard
will display a graph of the breath flow and
the total liters of breath. This allows the
observer to visually monitor the subject’s
breath test. The instrument automatically
measures the subject’s breath flow and triggers the test when a satisfactory deep lung
breath sample is provided.
After a successful test the unit displays a visual
graph of the fuel cell reading while it is calculating the BAC produced from the test. The
graph is not a substitute for the subject’s
BAC reading.
5. Immediately after a negative test or within
5-10 seconds after a positive test, the
LifeGuard will display the test result.

8

9

6. You can recall the last test result anytime by
momentarily pressing the execute button.
7. The LifeGuard will power down after 2 minutes of inactivity. To turn the instrument off
immediately, press the power button for 3
seconds.

Calibration
All breath testers require periodic calibration to
maintain their accuracy. Your LifeGuard is designed
to be calibrated by a factory certified calibration
technician. It is recommended that your LifeGuard
be calibrated at least once every 12 months.
To have your instrument calibrated or serviced
email us at service@lifeguardbreathtester.com or
visit us at www.lifeguardbreathtester.com or call
1.877.266.1008.

Accessories
Visit us online at www.lifeguardbreathtester.com to
learn more about alcohol and to purchase
additional mouthpieces and other accessories for
your LifeGuard.

Service & Maintenance
For general maintenance we recommend wiping
the unit off with a soft cloth sprayed with a nonabrasive disinfectant cleaner. To obtain the longest
life from your LifeGuard, it is recommended that two

10

or three tests be taken at least every 30 days. This
prevents the fuel cell from drying out over extended
periods of non use. If you require service, email us at
service@lifeguardbreathtester.com or call
1.877.266.1008.
Disposal of Instrument
At the end of the instrument’s
service life:
• Do Not dispose of the LifeGuard
as unsorted municipal waste.
• Dispose of the instrument in
accordance with national waste
disposal regulations.

Certifications & Classifications
This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference
to radio or television reception, which can be
determined by turning the equipment off and on,
the user is encouraged to try to correct the inter-

11

ference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the
equipment and receiver.
• Consult the dealer or an experienced radio/TV
technician for help.
The LifeGuard product is classified according
to the degree of protection against electric
shock as type BF.

Warranty
The LifeGuard comes with a one (1) year limited
parts and labor warranty, effective on the date
of retail purchase. The warranty does not cover
product re-calibration, freight to the manufacturer,
misuse or abuse of the product. The manufacturer’s
warranty is voided if the unit has been opened by
anyone other than a factory trained technician.
Upon receipt of a defective instrument we will
at our discretion (1) repair the instrument; (2)
replace the instrument or; (3) issue a refund for
the purchase price and keep the instrument. If the
instrument is repaired, the manufacturer will pay for
shipment back to the customer (within Continental
USA only)
This warranty does not apply: (a) to consequences
caused by accident, abuse, tampering, misuse,
flood, fire, earthquake or other external causes; (b)
to consequences caused by operating the product

12

outside the permitted or intended uses described
by LifeGuard; (c) to consequences caused by service
performed by anyone who is not a representative
of LifeGuard or a LifeGuard Authorized Service Provider; or (d) to a product or part that has been made
modified to alter functionality or capability without
the written permission of LifeGuard.

Disclaimers
LifeGuard is a division of Lifeloc Technologies, Inc.
LifeGuard makes no warranties, expressed or implied, as to the ability of this product to determine
whether, or the extent to which, a test subject’s
mental or physical functioning, or judgment, may
be impaired by blood alcohol including whether the
test subject is intoxicated under any definition of
that word. LifeGuard expressly disclaims any liability
for direct, indirect, incidental, special, or consequential damages of any nature under any legal theory.
Any act or failure to act based on a reading from
this product shall be at the test subject’s or user’s
own risk. LifeGuard assumes no responsibility for
consequences to or of test subjects who use this
product and later are shown to have been under
the influence of alcohol or to have had their judgment or any mental or bodily function impaired by
alcohol. A low BAC reading does not mean that the
test subject’s physical or mental performance or
judgment (including reaction times) can respond to
an emergency.

13

LifeGuard is not responsible for any consequences
arising from failure to follow instructions or relating
to the product’s use.
TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY AND THE DISCLAIMERS SET FORTH ABOVE ARE
EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL
OR WRITTEN, STATUTORY, EXPRESSED, OR IMPLIED.
AS PERMITTED BY APPLICABLE LAW, LIFEGUARD
SPECIFICALLY DISCLAIMS ANY AND ALL STATUTORY
OR IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE AND
WARRANTIES AGAINST HIDDEN OR LATENT DEFECTS. IF LIFEGUARD CANNOT LAWFULLY DISCLAIM
STATUTORY OR IMPLIED WARRANTIES THEN TO THE
EXTENT PERMITTED BY LAW, ALL SUCH WARRANTIES SHALL BE LIMITED IN DURATION TO THE DURATION OF THE EXPRESS WARRANTY AND TO THE
REPAIR OR REPLACEMENT SERVICE AS DETERMINED
BY LIFEGUARD IN ITS SOLE DISCRETION. WARRANTY
IS VOID IF UNIT IS OPENED.
No LifeGuard reseller, agent, or employee is authorized to make any modification, extension, or
addition to this warranty. If any term is held to be
illegal or unenforceable, the legality or enforceability of the remaining terms shall not be affected or
impaired.
EXCEPT AS PROVIDED IN THIS WARRANTY AND

14

TO THE MAXIMUM EXTENT PERMITTED BY LAW,
LIFEGUARD IS NOT RESPONSIBLE FOR DIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
UNDER ANY LEGAL THEORY, INCLUDING BUT NOT
LIMITED TO LOSS OF USE; LOSS OF REVENUE OR INCOME; LOSS OF ACTUAL OR ANTICIPATED PROFITS
(INCLUDING LOSS OF PROFITS FROM A CONTRACT);
LOSS OF THE USE OF MONEY; LOSS OF ANTICIPATED
SAVINGS; LOSS OF BUSINESS; LOSS OF OPPORTUNITY; LOSS OF GOODWILL; OR LOSS OF REPUTATION.
Some countries, states and provinces do not allow
the exclusion or limitation of incidental or consequential damages or allow limitations on how long
an implied warranty or condition may last, so the
above limitations or exclusions may not apply to
you. This warranty gives you specific legal rights,
and you may also have other rights that vary by
country, state or province. This Limited Warranty is
governed by and construed under the laws of the
country in which the product purchase took place.

NEVER DRINK AND DRIVE
ALWAYS USE A NON-DRINKING
DESIGNATED DRIVER AFTER
DRINKING ALCOHOL
ANY LEVEL OF ALCOHOL
CAN CAUSE IMPAIRMENT

12441 West 49th Ave. #4,
Wheat Ridge, CO 80033
Tel: 877.266.1008 • Fax: 303.431.1423
www.lifeguardbreathtester.com

Part #51020 Rev 1.6

©2009 Lifeloc Technologies, Inc.

1/25/10



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Author                          : sean
Create Date                     : 2010:02:03 13:53:04-07:00
Modify Date                     : 2014:12:24 10:29:20-08:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Format                          : application/pdf
Title                           : LifeGuard Manual_CA1.indd
Creator                         : sean
Creator Tool                    : PScript5.dll Version 5.2
Metadata Date                   : 2014:12:24 10:29:20-08:00
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:5b20f473-3a75-4191-9444-ea589ca43672
Instance ID                     : uuid:63f4acf6-2a99-4a50-896e-6f75adfcd1cf
Page Count                      : 9
EXIF Metadata provided by EXIF.tools

Navigation menu