Suprtool 5.0 For HP E3000 Stchg50

User Manual: stchg50

Open the PDF directly: View PDF PDF.
Page Count: 9

Suprtool 5.0 for HP e3000:
Change Notice
by Robelle Solutions Technology Inc.
Program and manual copyright © 1981-2007 Robelle Solutions Technology Inc.
Permission is granted to reprint this document (but not for profit), provided that copyright notice is given.
Qedit and Suprtool are trademarks of Robelle Solutions Technology Inc. Oracle is a trademark of Oracle Corporation,
Redwood City, California, USA. Other product and company names mentioned herein may be the trademarks of their
respective owners.
Robelle Solutions Technology Inc.
Suite 372, 7360 137 Street
Surrey, BC Canada V3W 1A3
Phone: 604.501.2001
Fax: 604.501.2003
E-mail: sales@robelle.com
E-mail: support@robelle.com
Web: www.robelle.com
Contents
Introducing Suprtool Version 5.0 4
Introduction ............................................................................................................................... 4
Highlights in Suprtool 5.0.......................................................................................................... 4
Known Problems .......................................................................................................................5
Compatibility ............................................................................................................................. 5
CPU Serial Number and CPU Name (HPSUSAN & HPCPUNAME) ......................................5
Documentation........................................................................................................................... 5
Installation 6
Overview ...................................................................................................................................6
Ecometry Users.......................................................................................................................... 6
Instructions ................................................................................................................................6
Installation Assistance ...............................................................................................................6
Enhancements in Version 5.0 7
Introduction ............................................................................................................................... 7
InitExtents..................................................................................................................................7
Table command .........................................................................................................................7
Set ItemLock <fieldname> ........................................................................................................7
$Clean Function and Clean Command ......................................................................................8
Bugs Fixed 9
Bugs Fixed In Suprtool 4.9.04 ...................................................................................................9
Bugs Fixed In Suprtool 4.9.02 ...................................................................................................9
Bugs Fixed In Suprtool 4.9.01 ...................................................................................................9
Suprtool 5.0 for HP e3000: Change Notice Highlights 3
Introducing Suprtool Version 5.0
Introduction
Suprtool provides fast access to your data on the HP e3000. With Suprtool, you can
perform many necessary DP functions easily, with just a few simple commands. At
Robelle we are constantly working on your enhancement requests so that we can
include them every year when we release an updated version of Suprtool. Robelle we
are constantly working on your enhancement requests so that we can include them
every year when we release an updated version of Suprtool.
Highlights in Suprtool 5.0
Set InitExtents on was added to help with systems that may experience
large Extent B-Trees. This is currently experimental for some
customers who may be experiencing problems with large Extent B-
trees. (4.9.05)
Suprtool had some internal messages printing out on stdlist when the
Table command was used. (4.9.04)
Set Itemlock command has been added to support Item level locking.
(4.9.04)
Update from a table would incorrectly update records with spaces if the
record was not found. (4.9.04)
Suprtool version 4.9.03 was not released to the general public. (4.9.03)
Suprtool would incorrectly give an error with the Set Buffer command
with some values. (4.9.02)
Suprtool would leave a KSAM/iX file open if the task had an if
command. (4.9.01)
The $CLEAN function in Suprtool and Clean command in STExport
can now remove a character that needs to be cleaned and it does not
replace with a space, but rather shifts the text to the left and adds a
space to the end. (4.9.01)
Suprlink’s Join command would not build the output file large enough
if the input file flimit was significantly smaller than the Link file.
(4.9.01)
Suprtool 4.8.10 would abort on a duplicate none key operation on a file
greater than 5,000 bytes (approx) (4.9.01)
4 Enhancements in Suprtool 4.9.02 Suprtool 5.0 for HP e3000: Change Notice
Suprtool would not select the correct records for Ksam64 and
KSAM/XL files when using high speed access. (4.9.01)
The $number function would either add garbage onto the end of a
conversion or two zeroes if the field did not have a decimal point.
(4.9.01)
Known Problems
There are no known problems at this time.
Compatibility
Suprtool/iX is compatible with MPE V, MPE XL, and MPE/iX, including MPE/iX
6.5, 7.0 and MPE/iX 7.5.
The fix to the $number bug, creates an incompatibility if you used a work around by
dividing by 100 and truncating. We therefore added set numbug on, to retain the
behaviour that has the bug, you will need to turn on set numbug on. Therefore it is
the default behaviour that is incompatible. See details further on in this change
notice.
CPU Serial Number and CPU Name (HPSUSAN &
HPCPUNAME)
Suprtool and its associated products run only on CPUs whose serial numbers have
been encoded ("showvar hpsusan" on MPE/iX). They also may be encoded with your
HPCPUNAME values. If it fails to run and you get an "invalid HPCPUNAME" or
"invalid HPSUSAN" error message, contact Robelle for assistance.
Documentation
The user manual contains the full description of all the Suprtool suite of products
including Dbedit, Suprlink, STExport and Suprtool2, as well as usage tips and
commands for each. The manuals are up-to-date with all the latest changes. To see
only the changes in the latest version, see the "What's New" section of the manual, or
see the change notice.
You can download our manuals and change notices in PDF format or HTMLHelp
format (.CHM) and even order printed (hardcopy) manuals from our web site at:
http://www.robelle.com/library/manuals/
Suprtool 5.0 for HP e3000: Change Notice Highlights 5
Installation
Overview
We have two types of Installations, Tape and Download. We provide links to the
Installation instructions on our web site for each type of Install.
Ecometry Users
Users of the Ecometry application need to use the installation instructions supplied
by Ecometry Corporation. Those instructions have extra steps for updating the
Ecometry code accounts.
You will find the Ecometry version of these instructions at
http://www.robelle.com/ecometry/
Types of installations, tape, download combined qedit and suprtool tape.
Instructions
If you received a production release tape from Robelle, then you can install using the
instructions on this web page:
http://www.robelle.com/support/install/tape/stprod.html
If you downloaded the Suprtool production release from our web site then the
instructions can be found here for the ftp download method:
http://www.robelle.com/downloads/install-stprod-ftp.html
and here for the WRQ download method:
http://www.robelle.com/downloads/install-stprod-wrq.html
Installation Assistance
If you have any questions about the upgrade process or run into any problems, please
call us. Technical support is available on weekdays from 8 a.m. to 4 p.m. Pacific
time at 800.453.8970 or you can e-mail your question to support@robelle.com.
6 Enhancements in Suprtool 4.9.02 Suprtool 5.0 for HP e3000: Change Notice
Enhancements in Version 5.0
Introduction
Suprtool is constantly being updated with new features. The following section
describes the new enhancements to Suprtool since Suprtool 4.9.02.
InitExtents
Set InitExtents setting has been added to reduce the size of the extent B-trees for
some systems. Keep in mind that this will increase the size of the chunks that it
needs to have for large files. This is currently not the default and is in as an
experimental option at this time. It changes how extents are allocated on an FOPEN
call or creation of a new Output file in Suprtool.
You may experience Out of Disc Space errors in some cases if large chunks of disc
are not available.
Table command
Update from a table would incorectly move spaces to numeric fields if a matching
record was not found in the table.
Set ItemLock <fieldname>
Suprtool now supports Item Level locking thru the Set ItemLock <fieldname>
command. The set command must be specified after the Base and Get/Chain
command has been specified. For example:
!run suprtool.pub.robelle
base order,1,;
get dline
set itemlock item-num
del
out save,link
exit
Item Level locking is only effective for Deletes and Updates.
Suprtool 5.0 for HP e3000: Change Notice Highlights 7
$Clean Function and Clean Command
The $Clean function in Suprtool and Clean command in STExport now have the
ability to replace a character to be cleaned with null or nothing. If you set the
cleanchar as being:
>Set Cleanchar “<null>”
Suprtool will remove the character specified in the clean command and effectively
shift the text to the left and blank out the portion at the end.
8 Enhancements in Suprtool 4.9.02 Suprtool 5.0 for HP e3000: Change Notice
Bugs Fixed
Bugs Fixed In Suprtool 4.9.04
Table Command. The Table command had some internal message printing
to $stdlist when the Table file was opened.
Table Command. Update from a table would incorrectly update numeric
fields with spaces if the record was not found in the table.
Bugs Fixed In Suprtool 4.9.02
Set Buffer. Suprtool would incorrectly give an error with the Set Buffer
command with some values.
Bugs Fixed In Suprtool 4.9.01
Join Command. When the Join command was used in Suprlink and the
Input file has a considerably smaller flimit than the Join file, the Output file
would not be built large enough.
Dup Command. Suprtool 4.8.10 would abort on a duplicate none key operation on
a file greater than 5,000 bytes (approx)
Chain Command. Suprtool’s Chain command with a key value from a Table
would not find some entries in Master Datasets for an Omnidex key in
Omnidex 3.07.55.
KSAM files. Suprtool and FCOPY for that matter, would skip some records
when not accessing records with a ;nocopy file equation and using an if
command, or in the case of FCOPY, using the ;exclude option. Suprtool now
automatically detects when using an if command and re-opens with ;nocopy
access. Suprtool 4.9 would leave KSAM/iX files open when the task had an if
command in it, this is now fixed in Suprtool 4.9.01.
$Number Function. The $number function would either add garbage onto
the end of a conversion or two zeroes if the field did not have a decimal
point.
Suprtool 5.0 for HP e3000: Change Notice Highlights 9

Navigation menu