TalENTo plUS – MEDIUM
Digital DIN-rail time switches
•
•
•
•
•
•
•
•
•
•
•

Daily and weekly program
50 Memory spaces
Date-dependent switching programs
Automatic summer time /winter time changeover
3 years running reserve
Manual switch: FIX ON / FIX OFF
Free weekday block formation
Non-volatile memory (EEPROM)
Pulse and cycle function
Random switching
External input

• PC-supported program creation
• Synchronisation time/date though optical wave guides
Applications
• Advertising signs
• Street lighting
• Shop window lighting
• Home & work environment
• Devices, motors and pumps control
• Sun blinds
• Shutters control
• Simulation of home presence

Voltage

EaN-Code 4010940

ord.-No.

Icon

talento 471 plus
230 V/50-60 Hz
110-120 V/50-60 Hz
230 V/50-60 Hz

033941
034054
036188

03.75.0001.1
03.75.0005.1
03.75.0007.1

1x16 (8) A
250V~

talento 472 plus
230 V/50-60 Hz
110-120 V/50-60 Hz
230 V/50-60 Hz

033958
034061
036195

03.75.0002.1
03.75.0006.1
03.75.0008.1

1x16 (8) A
250V~

language

set 1
set 1
set 2

1x16 (8) A
250V~

set 1
set 1
set 2

talento 471 plus, talento 472 plus
7 x 24 h
External input for
Countdown or
Override

3a
Lithium

IR

talento 671 plus DCF
230 V/50-60 Hz
110-120 V/50-60 Hz
230 V/50-0 Hz
7 x 24 h

FIX ON/OFF
sec./min./days

033965
034047
036201

10a
Lithium

IR

sec./min./days

DCF 77
GPS

– IR interface included

Amplifier module talento VM plus, see page 30
Optical waveguide, see page 30
Radio antenna DCF77 and GPS, see page 32
Software talento dialog plus, see page 32
Assembly accessories see page 46

24

IR

Master
MEMORY
50

language set 1
D, GB, F, I, E, P, CZ, NL

RND

?

03.75.0003.1
03.75.0004.1
03.75.0009.1

FIX ON/OFF

External input for
Countdown or
Override

MEMORY
50
± 1h
AUTO

language set 2
GB, S, N, DK, FIN, L, H

1x16 (8) A
250V~

RND

?

± 1h
AUTO

language set 1
D, GB, F, I, E, P, CZ, NL
language set 2
GB, S, N, DK, FIN, L, H

set 1
set 1
set 2

talento plus – MEDIUM

Dimensions H x W x D (mm)
Distributor cut-out (mm)
Weight (g) approx.
Connection voltage
Power consumption at  230 V AC
AC switching capacity
– ohmic load (VDE, IEC)
– inductive load cos. ϕ 0.6
– Incandescent lamp load
DC switching capacity
24 V DC/50 V DC/220 V DC
Switch contacts
Ambient temperature
Protection class
Accuracy
Power reserve
Shortest switching time
Programmable every
Memory spaces
Manual switch
Block formation of weekdays
Holiday program/date range
Display lighting
Random generator
Switching state display
Pulse switching commands
Cycle switching commands
Summer/winter time changeover
External output
– Override
– Countdown
DCF 77 input
Max. Terminal capacity
Connection type
Sealable

Dimensional drawings / circuit diagrams:

talento 471 plus

talento 472 plus

talento 671 plus

45 x 35 x 60
46 x 36
170
230 V/50-60 Hz
110-120 V/50-60 Hz
5 VA

45 x 35 x 60
46 x 36
170
230 V/50-60 Hz
110-120 V/50-60 Hz5 VA
5 VA

45 x 35 x 60
46 x 36
220
230 V/50-60 Hz
110-120 V/50-60 Hz5 VA
5 VA

16 A/250 V AC
8 A / 250 V AC
1000 W

16 A/250 V AC
8 A / 250 V AC
1000 W

16 A / 250 V AC
8 A / 250 V AC
1000 W

800 mA / 300 mA / 150 mA
1 changeover contact
–10°C ... +55°C
II
typ ± 1 s/day at +20°C
3 years from factory at +20°C
1 sec
min
50
automatic
Fix ON/Fix OFF
free assignment
yes
yes
up to 30 min
yes
yes:   sec, min, h, days
yes:   sec, min, h, days
automatic / freely selectable / off
yes
yes
20 min / in steps of 30 sec
–
4 mm2
captive ± screw terminals
yes

800 mA / 300 mA / 150 mA
1 changeover contact + 1 NO
–10°C ... +55°C
II
typ ± 1 s/day at +20°C
3 years from factory at +20°C
1 sec
min
50
automatic
Fix ON/Fix OFF
free assignment
yes
yes
up to 30 min
yes
yes:   sec, min, h, days
yes:   sec, min, h, days
automatic / freely selectable / off
yes
yes
20 min / in steps of 30 sec
–
4 mm2
captive ± screw terminals
yes

800 mA / 300 mA / 150 mA
1 changeover contact
–10°C ... +55°C
II
typ ± 1 s/day at +20°C
3 years from factory at +20°C
1 sec
min
50
automatic
Fix ON/Fix OFF
free assignment
yes
yes
up to 30 min
yes
yes:   sec, min, h, days
yes:   sec, min, h, days
automatic / freely selectable / off
yes
yes
20 min / in steps of 30 sec
yes
4 mm2
captive ± screw terminals
yes

Time switches

Technical Data

talento 471 plus, 472 plus
talento 671 plus

talento 471 plus

talento 472 plus
CH1

CH1

M
~

L
N
L

talento 671 plus DCF
CH2

CH1

N

1

2

3

L

S
N
L

+   -

M
~

M
~

N

1

2

3

5

6

S

L

N

1

2

3

5

6

S

N
L

25



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2010:11:23 09:49:05+01:00
Creator                         : Adobe InDesign CS2 (4.0)
Modify Date                     : 2010:11:23 09:49:14+01:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2010:11:23 09:49:14+01:00
Creator Tool                    : Adobe InDesign CS2 (4.0)
Format                          : application/pdf
Document ID                     : uuid:c3761f15-4e16-43f6-9e26-1f3ae1b241ae
Instance ID                     : uuid:bbb2273c-4d1c-4f3c-95b0-2cf3b697a376
Producer                        : Adobe PDF Library 7.0
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu