Talento 791 792 Plus Dcf Data
User Manual: talento 791 792 plus dcf data
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
http://waterheatertimer.org/Intermatic-timers-and-manuals.html#Talento-400 TalENTo plUS – MEDIUM Digital DIN-rail time switches • • • • • • ASTRO function (talento 792 plus also with weekly program) Automatic summertime/wintertime changeover 3 years running reserve Manual switch: FIX ON/FIX OFF Free weekday block formation Non-volatile memory (EEPROM) Applications • Advertising signs • Street lighting • Shop window lighting Voltage EaN-Code 4010940 ord.-No. Icon talento 791 plus 230 V/50-60 Hz 230 V/50-60 Hz 034818 03.74.0001.1 03.74.0007.1 1x16 (8) A 250V~ talento 792 plus 230 V/50-60 Hz 230 V/50-60 Hz 034825 03.74.0002.1 03.74.0008.1 2x16 (8) A 250V~ language set 1 set 2 7 x 24 h set 1 set 2 MEMORY 50 talento 791 plus, talento 792 plus 3a Lithium FIX ON/OFF ± 1h AUTO ± 90 min language set 2 GB, S, N, DK, FIN, L, H ASTRO talento 791 plus DCF 230 V/50-60 Hz 3a Lithium DCF 77 GPS 034832 FIX ON/OFF 03.74.0003.1 ± 1h AUTO ASTRO Radio antenna DCF77 and GPS see page 32 Assembly accessories see page 46 26 language set 1 D, GB, F, I, E, P, CZ, NL ± 90 min language set 1 D, GB, F, I, E, P, CZ, NL language set 2 GB, S, N, DK, FIN, L, H 1x16 (8) A 250V~ set 1 talento plus – MEDIUM Dimensions H x W x D (mm) Distributor cut-out (mm) Weight (g) approx. Connection voltage Power consumption at 230 V AC AC switching capacity – ohmic load (VDE, IEC) – inductive load cos. ϕ 0.6 – Incandescent lamp load DC switching capacity 24 V DC/50 V DC/220 V DC Switch contacts Ambient temperature Protection class Accuracy Power reserve Shortest switching time Programmable every Memory spaces Astro program Astro offset Manual switch Block formation of weekdays Holiday program/date range Random generator Switching state display Pulse switching commands Cycle switching commands Summer/winter time changeover External output – Override – Countdown DCF 77 input Max. Terminal capacity Connection type Sealable Dimensional drawings / circuit diagrams: talento 791 plus talento 792 plus talento 791 plus DCF 45 x 35 x 60 46 x 36 170 230 V/50-60 Hz 5 VA 45 x 35 x 60 46 x 36 170 230 V/50-60 Hz 5 VA 45 x 35 x 60 46 x 36 170 230 V/50-60 Hz 5 VA 16 A / 250 V AC 8 A / 250 V AC 1000 W 16 A / 250 V AC 8 A / 250 V AC 1000 W 16 A / 250 V AC 8 A / 250 V AC 1000 W 800 mA / 300 mA / 150 mA 1 changeover contact –10°C ... +55°C II typ ± 1 s/day at +20°C 3 years from factory at +20°C – – – yes ± 90 min automatic Fix ON/Fix OFF – – – yes – – automatic / freely selectable / off – – – – 4 mm2 captive ± screw terminals yes 800 mA / 300 mA / 150 mA 2 changeover contacts –10°C ... +55°C II typ ± 1 s/day at +20°C 3 years from factory at +20°C 1 min min 50 (for channel 2) yes ± 90 min automatic Fix ON/Fix OFF – – – yes – – automatic / freely selectable / off – – – – 4 mm2 captive ± screw terminals yes 800 mA / 300 mA / 150 mA 1 changeover contact –10°C ... +55°C II typ ± 1 s/day at +20°C 3 years from factory at +20°C – – – yes ± 90 min automatic Fix ON/Fix OFF – – – yes – – automatic / freely selectable / off – – – yes 4 mm2 captive ± screw terminals yes Time switches Technical Data talento 791 plus, 792 plus (DCF) talento 792 plus talento 791 plus CH1 CH1 M ~ L talento 791 plus DCF CH2 CH1 M ~ N 1 2 3 L + - M ~ N 1 2 3 5 6 7 L N 1 2 3 5 6 27
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2010:11:23 09:47:54+01:00 Creator : Adobe InDesign CS2 (4.0) Modify Date : 2010:11:23 09:48:05+01:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2010:11:23 09:48:05+01:00 Creator Tool : Adobe InDesign CS2 (4.0) Format : application/pdf Document ID : uuid:dbd76280-2013-4bfa-a0d1-f9d910bd1b9b Instance ID : uuid:52d930a3-29c8-4363-8779-ab99ef2bec5a Producer : Adobe PDF Library 7.0 Page Count : 2EXIF Metadata provided by EXIF.tools