Thermostat OCC2 UK User Manual

User Manual:

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadThermostat-OCC2-UK-user-manual
Open PDF In BrowserView PDF
U SER M AN U AL

Introduction
The OCC 2 thermostat is capable of switching on your heating system at pre determined times on different days of the week. It is possible to set 4 periods
called events each day with different temperatures. From factory a default schedule is programmed suitable for most installations. Unless you change these
settings the thermostat will operate to this default program.
Working with lower temperatures during times that the room is unoccupied will lower your energy costs without reducing the comfort. The thermostat has an
adaptive function that automatically changes the start time of a heating period so that the desired temperature is reached at the time that you set. After 3
days the adaptive function has learned when the heating must be switched on.
Type OCC2-1991H1 has an external temperature sensor that is normally placed in the floor construction. In this configuration the thermostat controls the
temperature of the floor and not the temperature within the room.
Type OCC2-1999H1 has a built-in temperature sensor. In this configuration the thermostat controls the temperature of the room, and the external
temperature sensor should not be installed.
The thermostat has a pin button marked R, allowing you to reset the thermostat to factory settings. These are listed at the end of this manual with space for
you to record your own weekly schedule.
The display is backlit when operating the buttons. The heating element is switched off when the light is on in the display.
The heating system can be switched off on the built-in interrupter. The Microprocessor taking care of the time will still be supplied with power whereby time
and day will be maintained. When the heating is required and the thermostat is switched on, it will continue the 4-event programme based on present time
and day.

1. Getting started
Display symbols

Buttons

G
A

F

B

E

C

BR929A09

57426 01/06 - (BJ)

Type OCC2

H
I

M

D

R

N

J
L
K

A:

B:

C:

D:

H:

I:

J:

Pin button
adjust of
clock

On/off

Reset to
factory
setting

Adjustment
down

Clock
function

Manual
mode

Time and
temperature

E:

F:

G:

L:

M:

N:

OK accept

Adjustment
up

Display

Heating on

4-event symbol
%
Monitoring
Wake
of switch-on
Night
time

K:
Day number

Out
Home

Setting the thermostat into operation
First time power is connected the clock and day will be flashing and must be set. If you need to
adjust the time of the thermostat at a later date, insert a pin into the hole
for setting of time
and day. Adjustment must be made for summer and winter time.

☞

Press the UP ( ) or DOWN ( ) buttons to
select the correct time and press OK button (

☞

Then press the UP ( ) or DOWN ( ) button to
select the correct day and press OK ( ) button.

Type: OCC2

).
1-7

1

2. Daily use of the thermostat
4-event clock mode
The day has been split into 4 events describing a typical day. When the thermostat is in 4-event mode it will automatically adjust the temperature according
to the required temperature to the required time. As standard the thermostat has 5 days with 4 events, and 2 days with 2 events. Programming see 3.

4-event clock mode:
The clock function symbol (
Programming see 3.
Comfort mode:

☞



5 secs.

☞

 5 secs.

☞

) will be indicated.

Temporary override
To temporarily override the temperature in the 4-event schedule program, press the UP ( ) or DOWN ( ) button
once, to show the temperature, and press again to increase or decrease the temperature. The display will flash for
5 seconds, and will then revert to the time. The override will operate until the next programmed event when the
unit will resume the automatic programme.
Cancel comfort mode
To cancel the override state, press the OK (

Manual mode:

☞

) and one of the 4-event symbols (

) button twice.

Permanent override:
During holidays, the scheduled 4-event program can be overridden.
Press the OK ( ) button, and then the UP ( ) or DOWN ( ) button until the override temperature is set.
The unit will now operate to this temperature permanently.
Cancel manual mode
To cancel the permanent override state press the OK (

3. Programming
4-event time and temperature
For each event, the start time and required
temperature must be set.

Press OK (

) button once, and the unit will resume automatic function.

) button for 3 secs. to begin programming

Day 1 - 5

For example, in the morning you wish the heating to
start at 07:00 and the temperature to rise to 25˚C.
Press OK ( ) button for 3 seconds and the start time
is displayed. Change this to 07:00 with the
UP ( ) or DOWN ( ) button. Press OK ( ) to
confirm.
The temperature is now displayed. Change this to 25˚C
with the UP ( ) or DOWN ( ) button.
Press OK ( ) button to confirm. This action can now
be repeated for the second event.

☞

☞

: Time and temperature

☞

☞

: Time and temperature

☞

☞

: Time and temperature

These settings will be valid with days 1-5 showing on
the display. To program the days 6 and 7, repeat the
above. Days 6 and 7 are usually Saturday and Sunday,
and only have two events.

☞

☞

: Time and temperature

☞

☞

: Time and temperature

☞

☞

: Time and temperature

The temperature can be set within the range of +5 to
+40˚C. It is also possible to select the heating OFF at
that event by reducing the setting to 5˚C, and then
pressing the ( ) once more.

Day 6 - 7

2

4. Advanced settings and read-out

☞

✚

☞

Press both UP ( ) and DOWN ( ) buttons together for 3 seconds. INFO is displayed.
Press UP( ) button until you reach the desired sub menu. Select the sub menu with the OK (

Monitoring of energy consumption
The thermostat calculates average time it has been switched on allowing you to monitor your energy consumption.
In the thermostat you can read out:. Total switch-on time in percentage in the latest 2 days, 30 days or 365 days.
Calculation of operational costs per day: (switch-on time:100) x kW x kWh-price x 24 h per day
Example: Read-out: 30 % in the latest 365 days
Size of heating system: 1,2 kW (ask the installer)
Cost of power: 0,2 EUR / kWh
Calculation: (30:100) x 1,2 kW x 0,2 EUR / kWh x 24 h = 1,7 EUR per day

}

2 days
30 days
365 days
Software version

☞

Actual sensor temperature

☞

}

☞
☞

) button to show the different

No changes can be made here. Use the OK (

) button to end.

5-2: 4 events in 5 days +
2 events in 2 days.
6-1: 4 events in 6 days +
2 events in 1 day
7-0: 4 events in 7 days

☞

Maximum allowed temperature setting. Use the UP ( ) or
DOWN ( ) button to increase or reduce, and OK ( ) button to
accept.

☞

Next is displayed LoLi. Press OK (

☞

Minimum allowed temperature setting. Use the UP ( ) or
DOWN ( ) button to increase or reduce and OK ( ) button to
accept.

) button to continue.

Time and temperature scale selection

☞

☞

☞

}

You can select either ˚C or ˚F scale, and 12 or 24 hour clock as
follows:
Press UP (

) or DOWN (

) button to change settings. Confirm

the required scale with the OK button (

) button.

Adaptive function
This function enables the thermostat to calculate when it needs to switch ON so that the required temperature is reached at the set
time. With a start time of 07:00 therefore, the thermostat may switch ON as early as 06:00 so that the desired temperature of 25˚C is
achieved by 07:00. Without this function set, the thermostat will start to heat at the time you set.

☞
☞

) or DOWN (

Max and min allowed temperature range
The temperature setting range of +5˚ to 40˚ C can be limited to prevent at comfort or manual mode a too high or too low temperature
being selected. For example, a wood floor covering should not be allowed to exceed a maximum of 27˚C. Low limitation is used where
the temperature of the floor is required never to fall below the minimum set temperature.

☞
☞

Press UP (
readouts.

4-event sequence
The present event sequence flashes: Days 1-5, followed by days 6-7. To change, press the UP ( ) button until you have days 1-6
and then day 7 flashing, or all 7 days are flashing. Select the required sequence with the OK ( ) button.

☞
☞

) button.

}

Press the DOWN (
Press OK (

) button to switch between on and off.

) button to confirm.

☞
☞

Press OK ( ) button to end programming and to return to
scheduled programme.

3

5. Reset to factory setting
Press the pin button for 3 secs. and the thermostat returns to factory settings. Time
and day is also reset and must be set according to “Setting the thermostat into
operation”.

Factory settings
4-event time and temperature
Day 1-5

Time

Temperature
OCC2-1991
w/floor sensor

OCC2-1999
w/room sensor

06:00

25˚C

20˚C

08:00

20˚C

15˚C

16:00

27˚C

22˚C

22:30

20˚C

15˚C

08:00

27˚C

22˚C

23:00

20˚C

15˚C

55˚C / 5˚C

28˚C / 15˚C

Day 6-7

Hi-Low temp.
4-event sequence

5:2

Scale

24 H / ˚C

Adaptive control

ON

6. Failure codes
E0 = Internal failure, replace thermostat
E1 = Built-in sensor short-circuit or disconnected, replace thermostat
E2 = External sensor short-circuit or disconnected
Warmup Plc
702 Tudor Estate
Abbey Road
London
NW10 7UW
T. +44 845 345 2288
F. +44 845 345 2299
warmup.com

4



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2006:12:06 11:37:01Z
Create Date                     : 2006:12:06 11:34:33Z
Metadata Date                   : 2006:12:06 11:37:01Z
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:78296148-853e-45ac-b749-11a6649738fb
Instance ID                     : uuid:6b774491-4934-470a-83ad-92cea82fbdd1
Producer                        : Acrobat Distiller 7.0 for Macintosh
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu