INSTRUCTIONS FOR 1830-185 TCP/IP MANUAL MODE to RS-232 CONVERTER KIT
Connection via INTERNET

General Information
System IP Address
Connection Option
Model Number
Area Codes
Dial

First, then

Network
DKS Cellular
DKS Data over IP
DKS VoIP Voice + Data
IM Server Modem
Modem to Modem
Network
RS 232

Network selected in Remote
Account Manager Software.

Use these instructions when using the TCP/IP adapter, part number 1830-185. This device is a manual
setup (no subscription required). For Plug and Play setup (no manual setup required) use TCP/IP adapter
part number 1830-186 (DKS Data over IP or DKS VoIP Voice + Data subscription service required).

System IP Address
Connection Option
Model Number
Area Codes

You can use the 1830-185 Converter Kit with the following DKS Systems:
1830 Series Telephone Entry and Access Control Systems (1833, 1834, 1835, 1837, 1838).

Dial

Refer to these instruction manuals for additional information:
P/N 1835-065 Telephone Entry Systems Installation Manual
P/N 1838-065 Access Controller Installation Manual
P/N 1835-066 Remote Account Manager Software User Manual

First, then

Network
DKS Cellular
DKS Data over IP
DKS VoIP Voice + Data
IM Server Modem
Modem to Modem
Network
RS 232

Network selected in Remote
Account Manager Software.

Connect Converter to 1830 Series Circuit Board RS-232 Terminals

LAN

Internet
Ethernet
10M/100M

Note:
RS-232 wire runs are limited to 500
feet maximum. If greater distance
is needed, use RS232 to RS422
Extender Kit, P/N 1830-190 (4000
Feet maximum distance).

Reload Defaults

Network
Pwr
DC 5-18V

Network
Interface
Device

Connection via LAN

Network
Interface
Device

Modem
N.I.D.

LAN

1

Router
2
3

4

Router
2
3

4

Ethernet wire runs
limited to 330 Ft.
Maximum.

DB - 25
PINS

1

3

2

Transmit Data

2

2

3

Receive Data

3

7

4

Request to Send

4

8

5

Clear to Send

5

5

7

Signal Ground - Shell

RS-232 & 485 To Ethernet

Reload Defaults

Network
Pwr
DC 5-18V

6
Ethernet
10M/100M

RS-232

P/N 1830-181 Rev F 4-18

RS-232

Red
3

9

Black
2
1

6
8
7
Brown White

RS-232 Cable
P/N 1818-040
(6 Ft. Cable)
A(+) B(-)
RS485

Ethernet wire runs
limited to 330 Ft.
Maximum.

Not Used

A(+) B(-)
RS485

Shield
+
Green
5

RS232 wire runs
limited to 500 Ft.
Maximum. See
note above.

FUNCTION

RED
BLACK
WHITE
BROWN
GREEN
SHIELD

1
2
3
4
5
6

RS-232 wire terminal
on telephone entry /
access control system
circuit board

Ethernet
10M/100M

Reload Defaults

1

DB - 9
PINS

RS-232 & 485 To Ethernet

Modem
N.I.D.

LAN

BOARD
TERMINALS

Network
Pwr
DC 5-18V

Network
Interface
Device

RS-232 & 485 To Ethernet

Internet

RS-232

A(+) B(-)
RS485

Use these programming instructions only if the factory defaults in the converter need to be changed
A Windows (Computer) Settings
The following defaults in the CONVERTER
are factory set. If they are satisfactory to
your system, there is no need to change
them.

Local Area Connection Properties

?

General Advanced

1

192.168.1.40
192.168.1.1
1040
19200

If these defaults are not
satisfactory, navigate to Local
Area Connections in Windows.
(Start – Control Panel – Network
Connections – Properties)

C Accessing the 1830-185 Menus

1.

Unplug the network cable from your PC.

1.

2.

Using the network cable supplied with the 1830-185 kit,
plug one end into your PC and the other into the
CONVERTER.

Connect using:

Configure...

Intel(R) 82566DM Gigabit Network C

IP Address:
Gateway:
Port:
Baud:

B Connect 1830-185 for Programming

This connection uses the following items:

3.

Power the CONVERTER with the supplied power supply.

4.

When completed, don’t forget to plug the network cable back
into the PC and the 1830-185 cable back into the router.

Open any browser and type in the address of the
CONVERTER: http://192.168.1.40

Port 0 Settings
The current settings for port 0 may be changed using the form below.

The user Log In window for the CONVERTER will appear.

Current Status
Local IP Config

Mozilla Firefox
File

Edit

View

History

Bookmarks

Tools

Help

Client for Microsoft Networks
File and Printer Sharing for Microsoft Networks
QoS Packet Scheduler
Internet Protocol (TCP/IP)

Install

Uninstall

Properties

Misc Config

Pass word:

Work Mode:
TCP Server detail:

*****

Remote Server Addr:

Reset

1

2

3

Enter the User name and pass word:
User name:
admin
Pass word:
admin

2

2

1

Local IP Config
RS232
RS485

Obtain IP address automatically

Web to Serial

Use the following IP address:

Ex: write down the numbers:

Default gateway:

Ethernet wire
runs limited to
330 Ft.
Maximum.

3

255 . 255 . 255 . 0
10 . 43 . 76 . 211

Misc Config

Module Name:
Firmware Revision:

USR-TCP232-410
3004

Current IP Address:
MAC Address:
Run Time:

192.168.1.40
d8-b0-4c-00-8d-55
0day: 0hour: 4min

TX Count(ETH):
RX Count(ETH):

Reboot

10.43.76.198
10.43.76.158

Preferred DNS server:

10 . 43 . 76 . 198

Alternate DNS server:

10 . 43 . 76 . 158

Current Status
Local IP Config

0/0/0 bytes
0/0/0 bytes

RS232
RS485

type

192.168.0.201

[N/A]

seconds (< 256, 0 for no timeout)

UART packet Time:

10

ms (< 256)

UART packet length:

512

chars (< = 1460, 0 for no use)

Cancel

IP type:

Static IP

Static IP:

192

168

1

40

Submask:

255

255

255

0

Gateway:

192

168

1
Save

1
Cancel

Notes:
These are the default settings and should be left alone. If the static IP address
is changed, the module will lose communication with the PC. You will need to
log into the module at the new IP address using the browser.

D

You can access settings of the CONVERTER
by using the
menu at the left in the Status and Configuration screen. Only
selections 1, 2 and 6 apply to this module.

Cancel

?

You can get IP settings assigned automatically if your network supports
this capability. Otherwise, you need to ask your network administrator
for the appropriate IP settings.
Obtain IP address automatically
Use the following IP address:
IP address:
Subnet mask:
Default gateway:

Ethernet
10M/100M

RS-232 & 485 To Ethernet

General

(This will allow your PC to connect to the
CONVERTER so that you can change its
settings.)

None

default

Advanced

Internet protocol (TCP/IP) Properties

Change IP Address to:
192.168.1.1

TCP Server

Reboot

OK

3

23

Misc Config

Reload Defaults

Preferred DNS server:
Alternate DNS server:

1040

IP Address Selection

Web to Serial

Use the following DNS server address:

Network
Pwr
DC 5-18V

10.43.76.171
255.255.255.0
10.43.76.211

bit

Notes:
Baud Rate can only be set to 9600 or 19200. These are the only two speeds that 1830 Series boards will run at.
Leave all other settings as shown when the converter is used in the Server Mode.

Obtain DNS address automatically

IP Address:
Subnet mask:
Default gateway:

1

Hardware

Current Status

You can get IP settings assigned automatically if your network supports
this capability. Otherwise, you need to ask your network administrator
for the appropriate IP settings.

(these numbers will not be the same in your
computer)

None

Save

Status and Configuration

Subnet mask:

bps
bit

Sync Baudrete (RF2217 similar):

?

10 . 43 . 76 . 171

8

4

Cancel

General

19200

0

Timeout:

Router

The Status and Configuration window will appear.

IP address:

Flow Control and RS485:
Local Port Number:

User name: admin

2.

Before proceeding, write down the
numbers (or take a screen print) in this
window. You are only going to change the
IP Address and you will need to put the
same IP Address number back when
programming of the CONVERTER is
complete.

Parity:
Stop Bits:

Remote Port Number:

Modem
N.I.D.

Notify me when this connection has limited or no connectivity

Internet protocol (TCP/IP) Properties

Data Size:

Please login:

Show icon in notification area when connected

OK

Baud Rate:

RS485

Reboot

Description
Transmission Control Protocol/Internet Protocol. The default
wide area network protocol that provides communication
across diverse interconnected networks.

Then click Properties to show the Internet
Protocol (TCP/IP) Properties Window.

RS232
Web to Serial

http://192.168.1.40

Login

Highlight Internet Protocal (TCP/IP)

D Changing 1830-185 Settings

192 . 168 . 1 . 1
255 . 255 . 255 . 0
192 . 168 . 1 . 40

Obtain DNS address automatically

It is highly recommended that you DO NOT change the password
on the authentication screen. DoorKing will not be able to assist
you if you don’t know your ID or password. This system status
window is informational and there’s no need to change anything
here.

Reset:
1. Remove power from module.
2. Press the Reload button and apply power.
3. Hold the reload button for 3 seconds, then release.
Module is now reset. TCP IP address will be 192.168.1.40. User
name and password will be admin. All other settings will need to
be configured.

Use the following DNS server address:

IMPORTANT! When you are finished
configuring the CONVERTER, you must set the
IP Address back to the original settings in order
to get access back to your network.

Preferred DNS server:

10 . 43 . 76 . 198

Alternate DNS server:

10 . 43 . 76 . 158

RS-232

A(+) B(-)
RS485

IMPORTANT! When you are finished configuring the CONVERTER, you must set the Internet Protocol (TCP/IP) Properties screen on your PC
back to its original settings in order to get access back to your network.

Advanced

Follow the instructions
OK

A

1 to get to the Internet Protocol (TCP/IP) Properties screen and then put your old settings back.

Cancel

Don’t forget to plug the netowrk cable back into the PC

B

1

and the CONVERTER cable back into the router.

B

2

A

2



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08
Create Date                     : 2018:04:18 10:39:51-07:00
Creator Tool                    : Acrobat PDFMaker 11 for Visio
Modify Date                     : 2018:04:18 10:39:55-07:00
Metadata Date                   : 2018:04:18 10:39:55-07:00
Producer                        : Acrobat Distiller 11.0 (Windows)
Format                          : application/pdf
Creator                         : RS217
Title                           : 
Document ID                     : uuid:2a6658e2-76dc-468d-b75f-c6a89f55e1df
Instance ID                     : uuid:0e9ef88f-cdc5-45bb-a47c-bfc822a5627d
Page Layout                     : SinglePage
Page Count                      : 2
Author                          : RS217
EXIF Metadata provided by EXIF.tools

Navigation menu