Dorma ED900 Power Cord Install Inst Installation Instructions 08121030 Ins 8 14

User Manual: Dorma ED900 Power Cord Installation Instructions Installation Instructions

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadDorma ED900 - Power Cord Install Inst Installation Instructions 08121030-ins-ed900-power-cord-8-14
Open PDF In BrowserView PDF
ED900 POWER CORD INSTALLATION
—
Installing the power cord

ATTENTION! Connect the power cord to 120V 60 Hz ONLY.
WARNING! Power cords pose a rise of becoming entrapping in moving parts of the operator, door or system.

The flexible power cord should not be routed through doorways, window openings, walls, ceilings, floors, or the like. The
cord should also not be attached or secured to the building structure. The cord cannot be concealed behind walls and the
like. Make sure the power cord does not become entrapped in any moving parts of the operator, door, or system.

To reduce the risk of electric shock, this equipment has a grounding type plug, that has a third (grounding) pin. This plug
will only fit into a grounding type outlet. IF the plug does not fit into the outlet, contact a qualified electrician to install
the proper outlet. Do not change the plug in any way.

For in-wall mounting: When installing the socket, please remember that the socket should be reached by hand.
(maximum 14" away)

1

2
1. 110V power cord
2. Conduit box
3. Cord grip
4. Wire nut
4

3

Screw
1.1

Terminal block
Mounting
plate

Conduit box
Bushing

Disassemble the conduit box assembly, by removing
the pan head screw from the terminal block using a #1
phillips screw driver.

1.2 Slide the conduit box underneath the mounting plate.
1.3 Insert the pan head screw into the terminal block,
bushing and conduit box by using a #1 phillips screw
driver (5in-lbs).

1

1

DORMA AMERICAS, Inc. Dorma Drive, Drawer AC
08122560
08/14
Reamstown, PA 17567

Toll-Free: 800-523-8483
Fax:
800-274-9724

E-mail: dormaarchitectural@dorma.com
Subject to change without notice

ED900 POWER CORD INSTALLATION

Conduit box

Hole

Cord
grip
2
2.1

Punch out the hole in the conduit box best suited for the
application.

2.2 Place the power cord into the grommet portion of the
cord grip and insert the cord grip into the hole using
pliers to compress it.

Wiring the ED900
Mounting plate/conduit box
Terminal block

Power cable

Housing
1
1.1

Loosen the terminal block connections and secure each
wire of the 110V power cable into its proper location on
the terminal block.





Black (live) = upper terminal
White (neutral) = lower terminal
Green (ground) = connect to ground wire

Terminal
block power
cable

ED900 unit

1.2 Align the mounting plate/conduit box assembly with the
bottom of the ED900 unit.
1.3 Feed the terminal block power cable through the bottom
of the plastic housing. CAUTION: DO NOT DAMAGE THE
WIRES.

Male
connection
end
2.1

Insert the male connection end of the main power cable
into the female connector inside the housing.

Female
connection
end

2

DORMA AMERICAS, Inc. Dorma Drive, Drawer AC
08122560
08/14
Reamstown, PA 17567

Toll-Free: 800-523-8483
Fax:
800-274-9724

E-mail: dormaarchitectural@dorma. com
Subject to change without notice

2



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : harshel
Create Date                     : 2014:08:26 13:52:38-04:00
Modify Date                     : 2014:09:12 08:15:22-04:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2014:09:12 08:15:22-04:00
Producer                        : Acrobat Distiller 11.0 (Windows)
Format                          : application/pdf
Title                           : ED900 - Power cord install inst.indd
Creator                         : harshel
Document ID                     : uuid:0ff8199b-e8f7-46f4-864a-0e034135ccd2
Instance ID                     : uuid:e98f17d2-f377-424f-bd45-f88ea8861e66
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu