Dorma DE5000 & DE9000 Series Delayed Egress Exit Device Ide 12 08 09
User Manual: Dorma DE5000 & DE9000 Series Delayed Egress Exit Device Installation Instructions
Open the PDF directly: View PDF .
Page Count: 11
Download | |
Open PDF In Browser | View PDF |
INSTALLATION INSTRUCTIONS DE5000 & DE9000 SERIES DELAYED EGRESS EXIT DEVICE Note: Refer to Individual Series Installation Instructions for templating and installation of device; @ www.dorma-usa.com These are additional instructions for installation and operation of the "Delayed Egress" unit. Specifications DE5300 DE9300 RIM 85 Decibel Alarm - Standard LED Status Indicator - Standard Nuisance Alarm - Standard Key Switch Control - Standard Remote Authorized Egress - Standard Remote Re-Arm - Standard Remote Bypass - Standard Door Position Input - Standard, DIP Switch Setting Auto Reset or Manual Reset, DIP Switch Setting Auto - Stanadard (Manual - in CA) Additional Form "C" Relays For Optional Horn etc. (Rated 1 amp @ 30 vdc) DE5500 DE9500 MORTISE DE5100 DE9100 CONCEALED VERTICAL ROD REQUIRES DORMA ES-100 or AD100 POWER SUPPLY. Easily accessible slide in and out electronics. Meets UL, ANSI/BHMA & CBC requirements. SIZE A: (DE9000 Series) Will fit 48" (1219 mm) door opening without cutting. Can be cut to fit a 40 1/2" (1029 mm) minimum door opening. SIZE B: (DE9000 Series) Will fit 36" (914 mm) door opening without cutting. Can be cut to fit a 34 1/2" (876 mm) minimum door opening. SIZE AA: (DE5000 Series w/ #443 strike) Will fit 48" (1219 mm) door opening without cutting. Can be cut to fit a 38 3/4" (984 mm) minimum door opening. SIZE BB: (DE5000 Series w/ #443 strike) Will fit 36" (914 mm) door opening without cutting. Can be cut to fit a 31 3/4" (806 mm) minimum door opening. Assembly NOTE: If cutting to length is required carefully remove filler and electronics for cutting. Use all grounding precautions. Mortise Cylinder (factory supplied) Pt. No. 90B10SC118 End Cap Bracket End Cap WIRE PIG TAIL Connecting Plugs Touchbar/Rail Assembly (Delayed Egress) Filler (DE9000/DE5000) NOTE: "Always disconnect power prior to making any connections or service!" Observe proper static discharge grounding procedures when installing or servicing the Delayed Egress device. 1135-88 95011817 1 IDE - 12 8/09 Cylinder Specification To Change Cylinder: Carefully remove filler from rail. Unscrew cylinder nut, remove actuator and replace cylinder. Spacer required for cylinders over 1 1/8". Insert cylinder as shown, re-install actuator & secure with cylinder nut. Do not over tighten. Re-install filler in rail and reconnect the small pigtail connectors. Use caution not to pinch or bind wires. Standard 1 1/8" mortise cylinder, randomly keyed supplied by factory. Spacer required for longer cylinder such as when using an IC core. Note: If DIP switch settings required to be changed, do it now prior to re-installing filler in rail. (See Section below.) 5/16" - 11/32" 1 1/8" Standard Cylinder Nut 4000-167-501 (6310D) CAM Actuator-DE 95055525 21/32" DE Filler Underside of Filler Cylinder 90B10SC118 DIP Switch Setting DIP switch settings should be completed at time of initial installation; check local building code. Factory settings are as follows: 1 - ON - NOT ACTIVE 2 - OFF - LOCKED 3 - ON - 3 SECONDS 4 - OFF - 10 SECONDS (1) DPS: (OFF) ACTIVE (ON) NOT ACTIVE (2) POWER UP STATE: (OFF) LOCKED (ON) UN-LOCKED (3) NUISANCE TIME: (OFF) 1 SEC. (ON) 3 SEC. (4) AUTHORIZED EGRESS TIME: (OFF) 10 SEC. (ON) 20 SEC. 1 ON OFF Underside of Filler 2 2 3 4 Basic wire connection DORMA MODEL ES100 24 VOLT DC POWER SUPPLY Specific project or custom wiring diagrams available on request, consult the DORMA techinical service department. NOTE: Always disconnect power prior to making any connections or service. It is recommended that the 120VAC power be supplied from an Uninterrupted Power Supply (UPS) to ensure proper operation during a power failure. Always observe proper static discharge grounding procedure's when installing or servicing the DE device. Wires that interconnect the remote authorized egress and remote by-pass/rearm must be located within the same room as the panic hardware (DE), or outside the door at no more than 10' feet of distance. PUSH TO RESET FUSE (AD100 220V Version Optional) CIRCUIT BREAKER 3.0 AMP 24VDC 3/4 AMP 120VAC REPLACE WITH 3AG 3/4 AMP SLO-BLOW TYPE FUSE ONLY ZONE 1 ZONE 2 OUTPUT CONTROL TERMINALS SWITCH 24VDC (+) (+) (-) (IN) 1 2 3 4 NO OUTPUT CONTROL TERMINALS SWITCH 24VDC (+) (+) (-) (IN) 5 6 7 8 TO N.C. CONTACTS IN FIRE ALARM CONTROL PANEL. For ULC installations: Some "Authorities Having Jurisdiction" also require an illumination level of 100' feet at the door, to be provided by the emergency power supply system. CONNECTION 9 10 11 12 Green Ground Screw Located On Chassis CAUTION: TURN OFF 120VAC POWER PRIOR TO MAKING ANY CONNECTIONS TO TERMINALS DORMA ES100 WHITE (NEUTRAL) BLACK (HOT) GREEN (GROUND) Minimum 18 AWG wire recommended for 24VDC inputs (red & black) leads. 120 VAC From UPS POWER LINE Power Source (1.0 AMP MAX.) Control Inputs Monitoring Outputs Grey DPS Black DORMA ES105 (Power Transfer) "Recommended" (See Page 6 for typical wiring of control inputs and monitoring outputs.) (12) Wire Connection Bundle 22" in length. BLACK: (-) 24VDC IN RED: (+) 24VDC IN WHITE: AUTHORIZED EGRESS/AUTO RESET ORANGE: BYPASS/RE-ARM GREY: DPS N/C VIOLET: ALARM RELAY COMMON GREEN: RED OUTPUT EMITTER BROWN: RED OUTPUT COLLECTOR BLUE: GREEN OUTPUT EMITTER YELLOW: GREEN OUTPUT COLLECTOR PINK: ALARM RELAY N/C TAN: ALARM RELAY N/O Maximum Wire Length From Power Supply To Device & Back To Supply In Feet x Wire Gage/Size WIRE 18AWG FEET 25 16AWG 50 14AWG 12AWG 75 100 * For 24VDC inputs only (red & black wires). Note: Wire run is from supply to device and back to the supply. 3 Key switch operation for device. Delayed Egress Mode: Unit is armed and touch bar will not activate the latchbolt. (LED is solid green, audible alarm is off). Initiated after power up, (DIP switch #2 in OFF position) authorized egress mode or re-arm mode. Nuisance Alarm Mode: Unit is armed and touch bar will not activate the latch bolt. (LED is solid green, audible alarm sounds a short tone) DIP switch selectable for 1 or 3 seconds. (See page 2) Initiated by depressing touch bar. Delay Mode: Unit is armed and touch bar will not activate the latch bolt. (LED is solid yellow, audible alarm sounds intermittent tone). Unit remains in the delay mode for 15 seconds ( including nuisance time). Initiated by holding the touch bar depressed past the nuidance alarm time (30 second delay mode option available.) Once started, the delay mode is irreversible and automatically initiates the alarm mode. Alarm Mode: Unit is disarmed and touch bar will activate the latch bolt (LED is solid red, audible alarm sounds continous tone). Initiated automatically from the delay mode and is irreversible. Unit remains in the alarm mode until manually reset with key. By-Pass Mode: From the delayed egress mode; unit is continuously disarmed and touch bar will activate the latch bolt (LED slowly flashes green, audible alarm is off). Initiated by rotating the key clockwise until switch activates (approximately 180 degrees). DPS input is disabled. Re-arm Mode: From alarm mode; unit goes to the delayed egress mode. Initiated by rotating the key clockwise until switch activates (approximately 180 degrees). From the bypass mode; unit goes to the delayed egress mode. Initiated by rotating the key clockwise until the switch activates (approximately 180 degrees.) The LED will return to solid green. Bypass/Re-arm Rotate Clock-wise Authorized Egress Mode: Unit is disarmed for 10 or 20 seconds (DIP switch selectible) and touch bar will activate the latch bolt (LED quickly flashes green, audible alarm is off). After the authorized egress time unit returns to the delayed egress mode automatically. The authorized egress mode is initiated by rotating the key counter-clockwise until switch activates (approximately 180 degrees). DPS input will not initiate during the 10 or 20 second egress time, but will terminate the egress time if the DPS closes before the end of the egress time. DPS input will initiate an alarm after the 10 or 20 second egress time, if the DPS is opened. Rotate Counter Clock-wise Authorized Egress NOTE: The By-pass mode and Re-arm mode (orange wire) may be intiated externally from the terminal connector. (Normally open dry contact to ground.) The Authorized Egress mode (white wire) may be initiated externally from the terminal connector (Normally open dry contact to ground). See page 6 for addtional details. 4 Cover, end cap and label After all wire connections are made and device checked for operation, install the chassis cover, end cap and label as shown below. NOTE: Compliance with the California Building Code (CBC) requires different label then supplied. The CBC label is shown below. If required, order through Service Parts, model number CBCLBL. Consult with local code & "authority's having jurisdiction". See CBC Secton 1003.1.10 Paragraph 6. KEEP PUSHING. THIS DOOR WILL OPEN IN 15 SECONDS. ALARM WILL SOUND. NOTE: To enable the device to power up in the unarmed mode, set Dip switch #2 in the "ON" position. A green blinking light will appear. Device will required to be manually armed with a key at the device or from the remote console. (See page 4 under rearm mode, for key operation.) LED light codes: Solid Green - Delayed Egress Mode Slow Flashing Green - Bypass Mode Fast Flashing Green - Authorized Egress Mode Solid Yellow - Delay Mode Solid Red - Alarm Mode Latch guard For added security a latch guard is supplied with the delayed egress Strike & Latch device. Install along with the standard Guard Installation. #463 strike as shown. Correct reference dimension of 2 3/8" from edge of stop or mullion must be maintained. #463 strike It is recommended that the following routine maintenance checks be performed at intervals of not less than once a month, and as a requirement by the local authority having jurisdiction, by the occupant or his approved representative: a) Inspect and operate the panic device to ensure that all components are in satisfactory working conditon. b) Ensure that all strikes are free from obstruction. c) Ensure that the fire alarm system and electronic function of device are in working order. This product meets or exceeds the following standards: ANSI/BHMA 156.3, CBC Section 1003.1.10, California State Fire Marshal, NFPA 80 &101 and UL Listed FWAX, FWAX7 5 REMOTE CONTROL & MONITORING INPUT DORMA CC-400-D CONTROL CONSOLE SWITCH MOMENTARY-RESET-MOMENTARY Typical Diagram (EXT.) ALARM (LED ON CONTROL PANEL WILL EMIT SAME COLOR STATUS AS DE9000 DEVICE) UP COMMON DPS NC DOWN RED YELLOW GREEN RETURN (EXT.) DOOR SECURE LIGHT TAN PINK GRAY VIOLET GREEN BROWN BLUE YELLOW ORANGE WHITE BLACK FROM 24VDC + RED Typical Diagram REMOTE CONTROL INPUT DORMA K708 KEYSWITCH AUTHORIZED EGRESS MO (LEFT) BY PASS MA (RIGHT) BLACK ORANGE WHITE 6 FROM DE9000 FROM DE9000 EXIT DEVICE Latch Guard Installation With #463 Strike LHR LHR 1 5/8" Edge of Stop or Mullion 2 3/8" Edge of Stop or Mullion VERTICAL REF. LINE 9300/F9300 VERTICAL REF. LINE 5300/F5300 For added security a latch guard is supplied with the delayed egress device. Install the latch guard along with the standard #463 strike as shown below. If (2) shims supplied are required to meet correct reference dimension the latch guard is the same thickness as (1) shim. Latch Guard #463 Strike NOTE: Prior to installing (2) strike securing screws, install chassis cover, ensure bolt fully engages strike, & chassis cover does not hit edge of latch guard as door swings open or closed. 95037043 www.dorma-usa.com 1-800-523-8483 I463LG 8/09
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2009:11:23 11:21:52-05:00 Creator : Adobe Acrobat 9.0.0 Modify Date : 2009:11:23 11:22:38-05:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2009:11:23 11:22:38-05:00 Creator Tool : Adobe Acrobat 9.0.0 Format : application/pdf Document ID : uuid:76debb51-c39b-49fc-914d-fed53f53d90b Instance ID : uuid:38610953-f6a3-4aeb-a719-ba0c4cd73eb1 Producer : Adobe Acrobat 9.0.0 Page Count : 11EXIF Metadata provided by EXIF.tools