Dr ger Safety and KGaA XPLORE8700 Powered Air Purifying Respirator User Manual 9031316 01 2016
Dräger Safety AG & Co. KGaA Powered Air Purifying Respirator 9031316 01 2016
Contents
- 1. user manual sheet
- 2. user manual
user manual sheet
Edition 01 - March 2016 - 90 31 316 Dräger X-plore 8000 System Europe (EU) Technical data frequency band(s): BT 2.1: 2402-2480 MHz USA “Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.” BT 2.1: 0.97 mW / -0.14 dBm EIRP “This device complies with part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: Inductive Applications: -2.30 dBμA/ m at 10m Inductive Applications 13.56 kHz transmitted power: Notes on approval EC-Declaration of Conformity This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation.” “EMC” related: “Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.” Canada “Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : l'appareil ne doit pas produire de brouillage, et l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. “ “This device complies with part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation.” Mexico “La operación de este equipo está sujeta a las siguientes dos condiciones: 1 es posible que este equipo o dispositivo no cause interferencia perjudicial y 2 este equipo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada.” “No. de Homologación IFT: RCPDRDR16-0964” NIOSH Approval Label Dräger Safety AG & Co. KGaA D-23560 Lübeck, Germany Phone: 011 49 451 882-0 or USA 1-800-1-800-437-2437 THESE RESPIRATORS ARE APPROVED IN FOLLOWING CONFIGURATIONS Respirator Components 23C-3099 OV/CL/SD/HC/HE 23C-3134 OV/HE 23C-3135 OV/HE 23C-3136 CL/HF/AM/MA/FM/HS/ SD/HC 23C-3137 CL/HF/AM/MA/FM/HS/ SD/HC 23C-3138 23C-DRA209 OV OV CL/HF/AM/MA/FM/HS/ SD/HC/HE CL/HF/AM/MA/FM/HS/ SD/HC/HE HE OV/HE CL/HF/AM/MA/FM/HS/SD/HC OV CL/HF/AM/MA/FM/HS/SD/HC/HE OV/CL/HC/SD/HE HE OV/HE CL/HF/AM/MA/FM/HS/SD/HC 23C-DRA210 OV 23C-DRA211 CL/HF/AM/MA/FM/HS/SD/HC/HE 23C-3139 23C-3140 23C-3141 21C-0978 23C-3142 23C-3143 23C-3144 23C-3145 23C-3146 21C-DRA190 23C-DRA191 HE 21C-DRA181 23C-DRA183 23C-DRA213 23C-DRA214 23C-DRA215 23C-DRA216 21C-DRA184 23C-DRA185 23C-DRA217 23C-DRA218 23C-DRA219 23C-DRA220 HE 6739540 6739575 6739590 6739565 6739560 6739570 R59565 R59585 R59620 R59600 R59640 R59650 R59630 R59610 R59700 R59710 R59720 R58332 R59750 R59566 R59563 R59564 R59730 R59863 R59760 R59740 R59670 R59660 6739605 Dräger X-plore 8000 Filter HE Dräger X-plore 8000 Filter OV Dräger X-plore 8000 Filter CL/HF/AM/MA/FM/HS/SD/HC Dräger X-plore 8000 Filter OV/AG/HE Dräger X-plore 8000 Filter OV/HE Dräger X-plore 8000 Filter CL//HF/AM/MA/FM/HS/SD/HC/HE Dräger X-plore 8000 Standard battery (4 h Rechargeable Batteries) Dräger X-plore 8000 High capacity battery (8 h Rechargeable Batteries) Dräger X-plore 8000 Standard hose (for Hoods) Dräger X-plore 8000 Flexible hose (for Hoods) Dräger X-plore 8000 Standard hose (for Helmets and Visors) Dräger X-plore 8000 Flexible hose (for Helmets and Visors) Dräger X-plore 8000 Standard hose (for FFM) Dräger X-plore 8000 Flexible hose (for FFM) Dräger X-plore 8000 Standard belt Dräger X-plore 8000 Decon belt Dräger X-plore 8000 Welding belt Spare visor AC for X-plore 8000 Helmet with visor Belt extension for X-plore 8000 Standard belt Dräger X-plore 8000 Flow measurement tube Dräger X-plore 8000 Plug (hose connection opening) Dräger X-plore 8000 Plug (blower inlet opening) Dräger X-plore 8000 Comfort pad Protective foils for X-plore 8000 Hood Belt extension for X-plore 8000 Decon belt, 35 cm Dräger X-plore 8000 Shoulder carrying system, all belts Dräger X-plore 8000 Hose Cover, disposable Dräger X-plore 8000 Hose cover, spark proof Dräger X-plore 8000 Odour Filter R56503 FPS 7000-RA-EPDM-L2-PC-CR R55790 R56310 FPS 7000-RA-EPDM-M2-PC-CR Dräger X-plore 6570 SI/PC R56502 FPS 7000-RA-EPDM-S1-PC-CR R55795 R59900 Dräger X-plore 8000 Protective Visor Dräger X-plore 6530 EPDM/PC R59920 X-plore 8000 welding visor ADF R55800 R59910 Dräger X-plore 8000 Helmet with PC visor, white Dräger X-plore 6300 EPDM/PMMA R58325 R59850 Dräger X-plore 8000 Helmet with PC visor, black Dräger X-plore 8000 Premium hood, short (L/XL) R59840 Dräger X-plore 8000 Premium hood, short (S/M) ABCFHIJLMNO ABCFHIJLMNO ABCFHIJLMNO ABCFHIJLMNOP ABCFHIJLMNOP ABCFHIJLMNOP ABCFHIJLMNOP ABCFHIJLMNO ABCFHIJLMNO ABCFHIJLMNOP ABCFIJLMNOP ABCFHIJLMNOP ABCFIJLMNOP OV/CL/HC/SD/HE OV/HE CL/HF/AM/MA/FM/HS/SD/HC OV CL/HF/AM/MA/FM/HS/SD/HC/HE OV/CL/HC/SD/HE 23C-DRA212 HE 21C-DRA188 OV/HE CL/HF/AM/MA/FM/HS/SD/HC OV CL/HF/AM/MA/FM/HS/SD/HC/HE OV/CL/HC/SD/HE Cautions and Limitations 2 ACCESSORIES R59580 ALTERN ATE VISOR Dräger X-plore 8000 Standard Charger R59810 Dräger X-plore 8000 Standard hood, short (L/XL) ALTERNATE CARRYING HARNESS ALTERNATE HOSES R58329 R59800 Dräger X-plore 8000 Standard hood, short (S/M) ALTERNATE BATTERIES Ear Muffs for X-plore 8000 Helmet with visor, pair R59870 Dräger X-plore 8000 Premium hood, long (L/XL) ALTERNATE COMBINED FILTER CARTRIDGES R58328 R59860 Dräger X-plore 8000 Premium hood, long (S/M) ALTERNATE GAS CARTRIDGES 6739600 R59830 Dräger X-plore 8000 Standard hood, long (L/XL) HE OV/CL/SD/HC/HE HE FILTER Protective foils for X-plore 8000 Helmet with visor and Protective visor R59820 Dräger X-plore 8000 Standard hood, long (S/M) 21C-0971 23C-3098 21C-0972 ALTERNATE FACEPIECE Splashguard lid for odour filter PROTECTION 1 Dräger X-plore 8500 Blower unit for PAPR X-plore 8000 system; water and du R59500 BASIC UNIT TC- ABCFHIJLMNOP ABCFIJLMNOP ABCFHIJLMNOP ABCFHIJLMNO ABCFHIJLMNO ABCFHIJLMNOP ABCFHIJLMNOP ABCFIJLMNOP ABCFHIJLMNOP ABCFHIJLMNO ABCFHIJLMNOP ABCFIJLMNOP ABCFIJLMNOP ABCFHIJLMNOP ABCFHIJLMNO ABCFHIJLMNO ABCFHIJLMNOP ABCFHIJLMNOP ABCFIJLMNOP ABCFHIJLMNOP ABCFHIJLMNO ABCFHIJLMNO ABCFHIJLMNOP ABCFHIJLMNOP 1. Protections HE-High Efficiency Particulate Air filter for powered air-purifying respirators OV - Organic Vapor CL - Chlorine SD - Sulfur Dioxide HC - Hydrogen Chloride HF - Hydrogene Fluoride AM - Ammonia MA - Methylamine FM - Formaldehyde HS - Hydrogen Sulfide 2. Cautions and Limitations A - Not for use in atmospheres containing less than 19.5 percent oxygen. B - Not for use in atmospheres immediately dangerous to life or health. C - Do not exceed maximum use concentrations established by regulatory standards. F - Do not use powered air-purifying respirators if airflow is less than four cfm (115 lpm) for tight fitting facepieces or six cfm (170 lpm) for hoods and/or helmets. H - Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters are replaced before breakthrough occurs. I - Contains electrical parts that may cause an ignition in flammable or explosive atmospheres. J - Failure to properly use and maintain this product could result in injury or death. L - Follow the manufacturer's User's Instructions for changing cartridges, canister and/or filters. 90 31 316 - SD 1412.870 © Dräger Safety AG & Co. KGaA Edition 01 - March 2016 Subject to alteration M - All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations. N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer. O - Refer to User's Instructions, and/or maintenance manuals for information on use and maintenance of these respirators. P - NIOSH does not evaluate respirators for use as surgical masks. Dräger Safety AG & Co. KGaA Revalstraße 1 23560 Lübeck, Germany www.draeger.com Tel Fax +49 451 882 0 +49 451 882 20 80
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Author : hamerflo Create Date : 2008:07:15 11:00:00Z Modify Date : 2018:02:14 09:01:16+01:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Creator Tool : FrameMaker 12.0.3 Metadata Date : 2018:02:14 09:01:16+01:00 Format : application/pdf Title : 9031316_01_2016.fm Creator : hamerflo Producer : Acrobat Distiller 10.1.15 (Windows) Document ID : uuid:234e438d-8124-4391-b513-d3efb4021309 Instance ID : uuid:aa42518f-e83b-45c3-9770-fbe87e2e1799 Page Mode : UseOutlines Page Count : 2EXIF Metadata provided by EXIF.tools