DragonWave LT5GT Microwave Outdoor Unit User Manual LITE R1 0 Installation Guide Revision 2
DragonWave Inc. Microwave Outdoor Unit LITE R1 0 Installation Guide Revision 2
Contents
- 1. Harmony Lite 5GHz_Installation Guide
- 2. Harmony Lite 5GHz_User Manual
Harmony Lite 5GHz_Installation Guide
LITE, R1.0 Installation Guide Revision 2, updated in May, 2014 Notice This document contains DragonWave proprietary information. Use, disclosure, copying or distribution of any part of the information contained herein, beyond that for which it was originally furnished, requires the written permission of DragonWave Inc. The information in this document is subject to change without notice and relates only to the product defined in the introduction of this document. DragonWave intends that information contained herein is, to the best of its knowledge, correct and accurate. However, any/all liabilities associated with the use or accuracy of the information contained herein must be defined in a separate agreement between DragonWave and the customer/user. Copyright © DragonWave Inc. 2014. All rights reserved. Table of Contents 1 Preface .................................................................................................... 5 1.1 History of changes ........................................................................................................... 5 1.2 Scope of the document .................................................................................................... 5 1.3 Intended audience ............................................................................................................ 5 1.4 Document structure .......................................................................................................... 5 2 Before installation .................................................................................. 7 2.1 Precautions ...................................................................................................................... 7 2.2 Needed parts .................................................................................................................... 8 3 Mounting Steps .................................................................................... 11 3.1 Mounting on the wall ...................................................................................................... 11 3.2 Mounting on the pole (1’ ~ 1.75’ diameter) .................................................................... 13 3.3 Mounting on the pole (1.75’ ~ 3’ diameter) .................................................................... 13 3.4 Mounting on the pole (3’ ~ 4.55’) ................................................................................... 14 4 Cabling .................................................................................................. 17 4.1 Ethernet cable connection in the doghouse ................................................................... 17 4.1.1 P+E connection ................................................................................................................... 17 4.1.2 PoE+ connection ................................................................................................................. 18 4.2 External antenna connection .......................................................................................... 18 Preface 1 Preface 1.1 History of changes The history of changes is shown in the following table: TABLE 1. History of changes Revision Updates Update date 1st revision August, 2013 In Chapter 2, some warnings are added to meed the requirements. May, 2014 1.2 Scope of the document This document provides the guidance to install and commission the LITE system. INFO This document only concerns LITE system release 1.0 (LITE R1.0 in short) without specific statements in the context. 1.3 Intended audience This document is prepared for the use of technicians who are responsible for the system installation and commissioning. WARNING! PERSONS HANDLING THIS EQUIPMENT MAY BE EXPOSED TO HAZARDS WHICH COULD RESULT IN PHYSICAL INJURY! IT IS THEREFORE MANDATORY TO CAREFULLY READ AND UNDERSTAND THIS DOCUMENT. 1.4 Document structure The document is comprised of the following chapters. TABLE 2. Document structure Chapter Title Subject Chapter 1 Preface Provides an introduction on who and how to use this document. Chapter 2 Before installation Provides some information about the preparations and precautions before the installation. Chapter 3 Mounting steps Provides the mounting steps. Chapter 4 Cabling Provides the cabling guidance. Preface Before installation 2 Before installation 2.1 Precautions The radiation emitted by the antenna is low-power radiation and does not exceed the safety regulations. If the radio is operated without antenna, the safety limit is exceeded near the waveguide openings. WARNING! THE INSTALLATION MUST ONLY BE PERFORMED BY A QUALIFIED TECHNICIAN. WARNING! RISK OF PERSONAL INJURY. THIS PRODUCT MAY NEED TO BE INSTALLED ON A HIGH-RISE STRUCTURE SUCH AS A TOWER OR MAST. WHEN INSTALLING THE PRODUCT, WEAR A SAFETY HARNESS AND OTHER RELEVANT PROTECTIVE GEAR. IN ADDITION, FOLLOW ALL OCCUPATIONAL HEALTH AND SAFETY REGULATIONS APPLICABLE TO THE INSTALLATION. WARNING! HAZARDOUS ENERGY EXISTS WITHIN THE DEVICE. ALWAYS BE CAREFUL TO AVOID ELECTRIC SHOCK. WARNING! THE EQUIPMENT SHOULD BE LOCATED IN RESTRICTED ACCESS LOCATIONS. WARNING! WHEN INSTALLING THE UNIT, ALWAYS MAKE THE GROUND CONNECTION FIRST AND DISCONNECT IT LAST. WARNING! THE DEVICE MUST BE CONNECTED PERMANENTLY TO THE PROTECTION GROUND BEFORE AN OPERATION. THE CROSS-SECTIONAL AREA OF THE PROTECTIVE GROUND CONDUCTOR MUST BE AST LEAST 18AWG. WARNING! THE DEVICE MUST BE FIXED SECURELY ON RELIABLE OBJECTS. WARNING! REINFORCED INSULATION OR DOUBLE INSULATION MUST BE PROVIDED TO ISOLATE DC SOURCE FROM AC MAIN SUPPLY WHICH COMPLIES WITH REQUIREMENTS IN IEC 60950-1 BASED SAFETY STANDARDS. The following restrictions must be considered before installing the equipment: • The weather conditions must be taken into account when installing the equipment. The maximum and minimum temperatures at the installation location must remain within the acceptable range. For cable installation temperatures, refer to the cable manufacturer’s specifications. • The mounting pole structure must be stable enough to keep the antenna within its 3dB beamwidth in all foreseeable wind conditions. • Do not install the equipment at a location where an unauthorized person can have access to the antenna radiation region or to the equipment itself. Before installation • When the equipment is installed in regions where the temperature falls below zero degree Celsius during the winter, ice can accumulate on the installation tower structure. Take precautions to avoid the breakage of antennas due to falling ice. Suitable protection can be achieved, by installing a metal grating above the antenna. 2.2 Needed parts Before starting the installation, verify that you have the correct equipment and that the equipment has not been damaged during transportation. The following parts are needed in the normal installation of the equipment: • 1 X LITE equipment; FIGURE 1. LITE appearance (with internal antenna) 223.1 mm 217.87 mm 190.14 mm 88.30 mm With 190x190 mm Internal Antenna 8.4 mm 86 mm With External Antenna 66 mm 8.4 mm For more information on the physical design of the equipment, refer to Volume 1, Chapter 4 Mechanical structure and interfaces. • 2 x pre-assembled outdoor Ethernet cables (length options: 1 m, 2 m, 5 m, 10 m, 30 m, 50 m, 70 m, 90 m); • 1 x grounding cable; Before installation • (Only needed when PoE+ function is required) 1 x Ethernet cable for LITE internal use (length: 0.12 m); • (Only needed when external antenna is used) 2 x pre-assembled antenna cable for sub-6 GHz with connectors (length options: 1 m, 2 m, 3 m, 4 m, 5 m); and • 1 set of mounting kit. FIGURE 2. Mounting kit items Item: 4 Nut M5 Qty: 4 Item:2 Flat washer M5 Qty: 4 Item: 3 Item: 1 Antenna/enclosure base bracket Qty: 1 Item: 6 Bolt M8x40 Qty: 4 Item: 7 Washer flat M8 Qty: 4 Item: 11 Clamping bracket Qty: 1 SHEET 1 OF 4 Item: 5 Arm bracket Qty: 1 Spring washer M5 Qty: 4 Item: 8 Washer spring M8 Qty: 4 Item: 9 Nut M8 Qty: 2 Item: 12 Bolt M8x70 Qty: 2 Item: 10 Wall/Poll bracket Qty: 1 Item: 13 Bolt M5x16 Qty: 4 MT-120018/A only INFO How to attach the mounting kit to the equipment? The following steps will be used in the equipment mounting steps. Steps: 1. Attach item 1 to the back of the equipment using item 2, 3 and 4 as shown. Verify that the orientation of the hole in item 1 is aligned with the elevation axis. Using tightening torque of 5.7 N/m. Before installation FIGURE 3. Step 1 4 3 2 x4 x4 x4 ELEVATION AXIS 2. Connect base bracket as shown. Connect item 5 to item 1 (mate the knurled surfaces) using item 6, 7, 8 and 9. Note that the bolt head shall be positioned in the socket of item 1. Using tightening torque of 24 N/m to the azimuth and elevation hardware. FIGURE 4. Step 2 7 8 9 10 7 8 9 Azimuth axis 10 Elevation axis Mounting Steps 3 Mounting Steps The equipment can be mounted in the following four options: • • • • Option 1: on the wall; Option 2: on the pole (1’ ~ 1.75’ diameter); Option 3: on the pole (1.75’ ~ 3’ diameter); or Option 4: on the pole (3’ ~ 4.55’ diameter). 3.1 Mounting on the wall Steps: 1. Install the M6 x 60 expansion bolt in the wall. FIGURE 5. Step 1 2. Attach the mounting kits to the wall by M6 x 60 expansion bolt. FIGURE 6. Step 2 3. Attach the mounting kits to the equipment. Refer to Chapter 2 Before installation. 11 Mounting Steps FIGURE 7. Step 3 4. Tighten the grounding cable in the equipment. FIGURE 8. Step 4 5. Install the grounding cable with the enclosed parts. FIGURE 9. Step 5 12 Mounting Steps 3.2 Mounting on the pole (1’ ~ 1.75’ diameter) Steps: 1. Attach the mounting kits to the equipment. Refer to Chapter 2 Before installation. 2. Pre-assemble the mounting bracket on the pole. FIGURE 10. Step 2 3. Tighten the nut with spanner. FIGURE 11. Step 3 4. Tighten the grounding cable in the equipment. 5. Install the grounding cable with the enclosed parts. 3.3 Mounting on the pole (1.75’ ~ 3’ diameter) Steps: 1. Attach the mounting kits to the equipment. Refer to Chapter 2 Before installation. 2. Pre-assemble the mounting bracket on the pole. 13 Mounting Steps FIGURE 12. Step 2 3. Tighten the nut with spanner. FIGURE 13. Step 3 4. Tighten the grounding cable in the equipment. 5. Install the grounding cable with the enclosed parts. 3.4 Mounting on the pole (3’ ~ 4.55’) Steps: 14 1. Attach the mounting kits to the equipment. Refer to Chapter 2 Before installation. 2. Pre-assemble the mounting bracket on the pole. Mounting Steps FIGURE 14. Step 2 3. Tighten the nut with a flat blade screwdriver. FIGURE 15. Step 3 4. Tighten the grounding cable in the equipment. 5. Install the grounding cable with the enclosed parts. 15 Mounting Steps 16 Cabling 4 Cabling 4.1 Ethernet cable connection in the doghouse Ethernet cables are connected in two options: • P+E • PoE+ 4.1.1 P+E connection FIGURE 16. P+E connection Doghouse Cover P+E OUT (ETH 2) (Empty) (Empty) P+E IN (ETH 1) For Cascading To IDU or to LITE (when cascaded) Waterproof Plugs Cabling Channels Steps: 1. Unscrew the doghouse cover and open it. 2. Unplug one of the waterproof plugs and connect the Ethernet cable from P+E IN (ETH 1) interface to an IDU outside through the cabling channel or to a LITE to which it is cascaded. 17 Cabling 3. (Optional) Unplug another waterproof plug and connect the Ethernet cable from P+E OUT (ETH 2) interface to a LITE for cascading through the cabling channel. 4. Close the doghouse. 4.1.2 PoE+ connection FIGURE 17. PoE+ connection Doghouse Cover P+E OUT (ETH 2) POE+ IN INTERNAL Internal Connection P+E IN (ETH 1) For Cascading Waterproof Plugs To IDU or to LITE (when cascaded) Cabling Channels Steps: 1. Unscrew the doghouse cover and open it. 2. Connect the INTERNAL interface and P+E IN (ETH 1) interface with a short Ethernet cable. 3. Unplug one of the waterproof plugs and connect the Ethernet cable from POE+ IN interface to an IDU outside through the cabling channel or to a LITE to which it is cascaded. 4. (Optional) Unplug another waterproof plug and connect the Ethernet cable from P+E OUT (ETH 2) interface to a LITE for cascading through the cabling channel. 5. Close the doghouse. 4.2 External antenna connection When external antenna is used, the following picture shows the connection of the antenna cables. 18 Cabling FIGURE 18. Antenna cable connection VER HOR 19 Cabling 20
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : nlin Create Date : 2014:05:09 10:11:56Z Modify Date : 2014:05:09 10:11:56Z XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 10.1.9 (Windows) Creator Tool : FrameMaker 11.0.2 Format : application/pdf Title : LITE, R1.0, Installation Guide, Revision 2.book Creator : nlin Document ID : uuid:fd58e5c4-070b-42e9-ae71-1165a07173cd Instance ID : uuid:fec68cbc-3de0-423a-87c7-dec6476682c1 Page Mode : UseOutlines Page Count : 20EXIF Metadata provided by EXIF.tools