Ducane Hvac Rlhf R80C Users Manual R 80c 100.pmd

RLHF-R80C Ducane RLHF-R80C Spec Sheet

RLHF-R80C to the manual 2129e27f-1691-408f-8c89-9087b6b0779a

2015-02-04

: Ducane-Hvac Ducane-Hvac-Rlhf-R80C-Users-Manual-515019 ducane-hvac-rlhf-r80c-users-manual-515019 ducane-hvac pdf

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadDucane-Hvac Ducane-Hvac-Rlhf-R80C-Users-Manual- Rlhf-r-80c-100.pmd  Ducane-hvac-rlhf-r80c-users-manual
Open PDF In BrowserView PDF
FEATURES
Heavy-duty 14 gauge steel heat exchanger with a
long lasting ceramic fiber combustion chamber
Easy access large diameter clean out ports in heat
exchanger
Foil-faced high density fiberglass insulation in cabinet
reduces heat loss and sound

Ducane Oil Furnace

RLHF-R80C

Cabinet has pre-painted steel for maximum durability
Slide-out blower design for easey cleaning and
service
Multi-speed direct drive blower assembly allows the
airflow to be matched to the application requirements
Dynamically balanced blower with resilient motor
mounts for smooth and quiet operation
Includes barometric damper
High efficiency air flow system to provide consistent
operation through all operating conditions
Honeywell 7184B primary control with 15 second pre
purge, interrupted ignition, limited reset, and LED
diagnostics
PSC burner motor with low amp draw and ball
bearings for long life
40 VA transformer (Direct drive only)
Limited life-time warranty on heat exchanger and five
year limited warranty on all parts

C

Model Number Guide
R

L

HF

80

C

112/125

D

12 -

1

R - Product Family

Revision Code

L - Oil

CFM x 100

HF-Horizontal/Counterflow Front Flue
HR-Horizontal Rear Flue

D - Direct Drive

80 - 80% AFUE

112/125 x 1,000
BTU Outupt
C - Series

Physical and Electrical
AFUE
(ICS)

Flue
Dia.
(in.)

81.0

2.0-3.0

6

120/60/1

15

40

225

81.0

2.0-5.0

6

120/60/1

15

40

265

83.0

2.0-3.0

6

120/60/1

15

40

225

81.0

2.0-3.0

6

120/60/1

15

40

225

Weight
(lb.)

Input
(Btuh)

Output
(Btuh)

.65GPH-80ºB
.75GPH-80ºB
.85GPH-80 B
RLHF80C112/125D20
1.00GPH-80 B
.50GPH-80 A
RLHR80C57/72D12
.65GPH-80oB
.65GPH-80 B
RLHR80C84/95D12
.75GPH-80 B

105,000
119,000
140,000
154,000
70,000
90,000
105,000
119,000

85,000
97,000
113,000
125,000
57,000
74,000
85,000
97,000

RLHR80C112/125D20

.85GPH-80 B
1.00GPH-80 B

140,000
154,000

113,000
125,000

81.0

2.0-5.0

6

120/60/1

15

40

265

RLHR80C196D24*

1.25GPH-80ºB
1.50GPH-80ºB

210,000
245,000

168,000
196,000

80.0

3.0-6.0

8

120/60/1

20

40

375

Model

Nozzle
Size

Max. Time
Delay
Trans.
Volts/
Breaker or
(V.A.)
Hz/Phase
Fuse
(amp)

Nom.
Cooling
Cap.

RLHF80C84/95D12

*Approved for horizontal applications only.

Blower Performance
Motor
Temp.
Blower
Size
Rise
Size
o
F
(hp)

Model

RLHF80C84/95D12

1/2

10 x 8

45-75

RLHF80C112/125D20

3/4

12 x 9

45-75

RLHR80C57/72D12

1/3

10 x 8

45-75

RLHR80C84/95D12

1/2

10 x 10

45-75

RLHR80C112/125D20

3/4

12 x 9

45-75

RLHR80C196D24

3/4

12 x 12

60-90

CFM @ ext. static pressure - in w.c.

Blower
Speed

.20

.30

.40

.50

.60

.70

.80

.90

High
Med High
Med
Low
High
Med High
Med
Low
High
Med High
Med
Low
High
Med High
Med
Low
High
Med High
Med
Low
High
Med High
Med
Low

1,410
1,340
1,236
1,090
2,072
1,794
1,515
1,355*
1,406
1,256
1,010
837
1,487
1,380
1,230
1,057
2,218
1,782
1,552
1,353*
2,560
2,100
1,580*
1,369*

1,320
1,282
1,175
1,037
1,995
1,750
1,482
1,326*
1,341
1,206
981
818
1,398
1,303
1,170
1,022
2,141
1,750
1,504
1,335*
2,500
2,030
1,520*
1,336*

1,280
1,190
1,092
975
1,950
1,690
1,430
1,290*
1,274
1,156
948
798
1,303
1,220
1,108
970
2,082
1,706
1,480
1,300*
2,450
1,980
1,480*
1,293*

1,195
1,100
1,015
900
1,900
1,630
1,388
1,233*
1,203
1,090
906
761
1,210
1,150
1,000
909
2,000
1,649
1,440
1,277*
2,390
1,960
1,433*
1,231*

1,090
1,016
918
855
1,850
1,585
1,320
1,176*
1,126
1,012
842
716
1,104
1,033
935
835
1,907
1,579
1,380
1,223*
2,230
1,870
1,378*
1,161*

1,000
900
845
771
1,700
1,495
1,257
1,109*
1,011
922
774
650
997
931
847
754
1,797
1,489
1,320
1,170*
2,100
1,820
1,277*
1,100*

850
801
732
665
1,650
1,380
1,160
1,045*
915
816
687
561
871
798
734
640
1,711
1,408
1,251
1,074*
1,940
1,750
1,175*
979*

790
680
600
547
1,500
1,299
1,066
1,000*
784
684
541
406
740
672
597
503
1,590
1,324
1,174
1,004*
1,800
1,635
1050*
850*

*Not recommended for heating. Temperature rise may be outside acceptable range.

Accessories
Description

Used with

Kit Number

Combustible Floor Base

RLHF/R84/95

ABASE537-1

Combustible Floor Base

RLHF/R112/125

ABASE538-1

Clean Brush Out Kit

All models

ABRSH380-3

Vestibule Kit

RLHF84/95

AVEST547-2

Vestibule Kit

RLHF112/125

AVEST548-2

Filter Kit

RLHF84/95

AFILT535-1

Filter Kit

RLHF112/125

AFILT536-1

Filter Kit

RLHR196

AFILT 561-1

Combustion Air Kit

All models

ABOOT571

Clean Out Cap Kit

All models

ACAP570

Tjernlund Side Wall Vent Kit1

All models

ASVNT522

Field Controls Side Wall Vent Kit2

All models

ASVNT523

1

This can be ordered from Tjernlund, part number SSIC.

2

This can be ordered from Field Controls, part number SWG-5-CK61.

Dimensions (in.)
Model
RLHF80C84/95D12
RLHF80C112/125D20
RLHR80C57/72D12
RLHR80C84/95D12
RLHR80C112/125D20
RLHR80C196D24

A
B
C
D
E
F
G
H J
K
L
59 20 1/2 20 1/2 18 1/4 18 1/4 1 1/4 1 1/4 18 18 1 1/4 1 1/4
59 23 1/2 23 1/2 21 1/4 21 1/4 1 1/4 1 1/4 21 21 1 1/4 1 1/4

M
32 1/2
32 1/2

N
P Q
R
S
10 1/4 3 53 3 14 1/2
11 3/7 3 53 4 3/4 14 1/2

59 20 1/2 20 1/2 18 1/4 18 1/4 1 1/4 1 1/4 18 18 1 1/4 1 1/4

32 1/2

10 1/4 3 53

3

14 1/2

59 23 1/2 23 1/2 21 1/4 21 1/4 1 1/4 1 1/4 21 21 1 1/4 1 1/4 32 1/2 11 3/7 3 53 4 3/4 14 1/2
67 26 1/4 26 1/4 23 1/2 23 1/2 1 3/8 1 3/8 24 24 1 1/8 1 1/8 36 5/16 13 1/8 15 50 20 3 1/8

Clearances (in.)
Horizontal
Model
Front
RLHF80C84/95D12
24
RLHF80C112/125D20
RLHR80C57/72D12
RLHR80C84/95D12
24
RLHR80C112/125D20
RLHR80C196D24

Counterflow
Above

Rear

Flue

Bottom

Model

1

1

7

1

RLHF80C84/95D12

Front Above Rear Flue

RLHF80C112/125D20
1

1

7

1

16

0

1

7

24

1

1

7

RLHR80C57/72D12
RLHR80C84/95D12
RLHR80C112/125D20

All specifications and illustrations
subject to change without notice and
without incurring obligations..
www.ducanehvac.com
For more information, contact your local Ducane distributor.
Form No. DRLHF-R80C-100 (7/06)
Printed in U.S.A.

©Allied Air Enterprises, A Lennox International company 2006

*DRLUF80C-100-7-06*



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PageMaker 7.0
Modify Date                     : 2007:01:30 09:52:49-05:00
Create Date                     : 2007:01:24 09:17:23-05:00
Metadata Date                   : 2007:01:30 09:52:49-05:00
Format                          : application/pdf
Title                           : rlhf-r-80c-100.pmd
Creator                         : dsb2
Document ID                     : uuid:87ff55a6-9256-4d73-813e-826e1a76c55d
Instance ID                     : uuid:8dd26f87-b071-11db-89e9-000d93335cac
Page Count                      : 4
Page Layout                     : SinglePage
Author                          : dsb2
EXIF Metadata provided by EXIF.tools

Navigation menu