Dunkirk DXL 170 User Manual BOILER Manuals And Guides 1308321L
User Manual: Dunkirk DXL-170 DXL-170 DUNKIRK BOILER - Manuals and Guides View the owners manual for your DUNKIRK BOILER #DXL170. Home:Heating & Cooling Parts:Dunkirk Parts:Dunkirk BOILER Manual
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
NATURAL GAS FIRED DRAFT BOILERS NATURAL GAS IRON SERIES FOR FORCED II HOT WATER TO LP CONVERSION MGB/OMGB/MCB/DXL Kit #'s CAST SIZES 550002663, THROUGH 550002664, 200 MBTU 550002665 Conversion kit shall be installed by qualified service agency in accordance with manufacturer's instructions PART# (QTY) and all applicable codes and requirements of authority having jurisdiction. If information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing personal injury or loss of life. Qualified service agency is responsible Pilot Orifice - Spark for proper installation of this kit. Installation is not proper and complete until operation of converted appliance is checked as specified in manufacturer's instructions supplied with the kit. Liquid Sealing Compound Orifice PB00208 (1) # 50 (2) # 47 (4) Label, "Nat to LP" Conversion Plate 240004822 Spring Kit Figure 1 - # 49 (4) (1) 140010 (i) 1272030 (i) Instructions Tools Required • Flat Head Screwdriver PART# (QTY) 240009725 Burners (i) Assembly • 1/4" Nut Driver ° 7/16" Open Ended Wrench ° 3/16" Allen Wrench ° 18" Manometer (or dial manometer) Converting Boiler From Natural Gas To Propane (LP): 1. Follow instruction TO TURN OFF GAS TO APPLIANCE. Verify electrical power is OFF. 2, Remove front panel. 3. Remove burner access door. 4, Remove main gas burner tubes. See Figure 1. 5. Remove main burner orifices. See Figure 1. 6. Install LP gas main burner orifices. Discard excess LP orifices. 7, Use 7/16" wrench, disconnect pilot tube from pilot. See Figure 2. 8. Remove pilot orifice. 9. Install LP gas pilot orifice. 10. Apply liquid sealing compound (provided) pilot assembly fitting. OR FtCES Figure DOOR 2 - Pilot Assembly Pilot Orifice----....._,. <_:_: to threads of 11. Reattach pilot tube to pilot and securely tighten. Figure 2. See Pilot Tube 12, Replace main gas burner tubes. P/N 240009725, Rev. C [10/2012] 13. Remove cover screw from gas valve pressure regulator. See Figure 3. Figure 3 - Gas Valve 14. Remove adjustment screw by turning counterclockwise _'_i. See Figure 4. 15. Remove stainless steel natural gas spring. INLET PRESSURE 16. Insert Red LP gas spring. 17. Install new adjustment with regulator top. PRESSURE REGULATOR ADJUSTMENT BENEATH COVER SCREW QUTLET PRESSURE --TAP screw. Assure screw top is flush 18. Turn pressure regulator adjustment screw clockwise eleven (11) complete turns. (This is starting point for manifold pressure,) 19. Install manometer to pressure tap on outlet side of gas valve. See Figure 3. NOTE: Gas inlet pressure should be between minimum of 11" w.c. and maximum of 14" w.c. 20. Turn electric and gas supply ON. Fire Hazard. Do not use matches, candles, open flames, or other methods providing ignition source. Failure to comply will result in death or serious injury. Figure 4 - Gas Valve Assembly Adjustment Screw ............... CAP SCREW ................. O-RUNG 21. Check for gas leaks around all gas connections using commercially available soap solution specifically made for leak detection. .............ADJUSTMENT SCREW 22. While boiler is running adjust manifold pressure to ii" water column by turning pressure regulator adjustment screw. Check for CO2 and CO levels to assure proper operation. 23. Turn electric and gas supply OFF. 24. Remove manometer. securely. C::_ .... : ............. SPRING < ........ ) Replace pressure tap cover screw 25. Install Black LP gas regulator adjustment with o-ring. See Figure 4. cover screw 26. Mount conversion label on gas valve (found in spring kit). 27. Turn electric and gas supply ON. 28. Cycle boiler to ensure proper operation and lighting. 29. Replace front panel. NOTE: Complete following steps to provide proper identification for customer service or technical support issues. BoilerSizeii , Orificeii 50,100,150,200 47 30. Copy serial number from old rating plate to new one. 125,170 49 31. Mount new rating plate adjacent to old one. 75 50 Parts for steps 16, 17, 25, and 26 are located in Honeywell LP gas conversion kit HW#393691 (ECR # 1272030) for VR8204r and VR8304 gas valves. Manufacturer ECR Honeywell PartNumber PB00208 390686-36
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 2 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Thu Mar 20 07:13:10 2014 Author : Title : Subject :EXIF Metadata provided by EXIF.tools