Size: MN 9100 (LR1)

Alkaline-Manganese Dioxide Battery
Nominal Voltage:

1.5 V

Nominal Internal
Impedance:

420 m-ohm @ 1kHz

Average Weight:
12.0
mm
10.9
0.5 mm
MIN.

4.7 mm
Max.
(+)

30.2 mm
29.1

9.0 gm (0.3 oz.)
3

3

Volume:

3.4 cm (0.21 in. )

Terminals:

Flat

Operating Temperature
Range:

-20 C to 54 C
o
o
(-4 F to 130 F)

NEDA/ANSI:
IEC:

910A
LR1

o

o

(–)

5.0 mm
MIN.

Dimensions shown are IEC/ANSI standards

o

o

Typical Discharge Characteristics at 21 C (70 F)
1.6

1.5

1.4

Voltage

1.3

1.2

1.1

1
5.1 OHM
0.9

0.8
0

0.5

1

1.5

2

2.5

3

Hours of Service

* Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts

and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.

This data is subject to change. Performance information is typical. Contact Duracell for the latest information

6/08

Zn/MnO2

N

Zn/MnO2

N
Size: MN 9100 (LR1)

Alkaline-Manganese Dioxide Battery
Typical Discharge Characteristics
1.6

1.5

Typical Discharge Characteristics
1.4
1.6

100 OHM

Voltage

1.3
1.5
1.2
1.4
1.1

Voltage

1.3
1

300 OHM
0.9

1.2

1.1
0.8
0

50

100

150

200

250

1

0
20 C

0
0 C

0
- 20 C

Hours of Service
0.9

0.8
0

10

20

30

40

50

60

70

80

Hours of Service

Typical Discharge Characteristics
1.6

300 OHM
1.5

1.4

Typical Discharge Characteristics
1.6

1.2

1000 OHM
1.5

1.1
1.4
1

0
0 C

0
- 20 C

0
20 C

1.3

0.9

0.8
0

50

100

150

Hours of Service

200

250

Voltage

Voltage

1.3

1.2

1.1

1

0
- 20 C

0
0 C

0
20 C

0.9

0.8

Berkshire Corporate Park
Bethel, CT 06801 U.S.A.
Telephone: Toll-free 1-800-544-5454
Internet: www.duracell.com

0

100

200

300

400

500

600

700

800

Hours of Service

* Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts

and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.

This data is subject to change. Performance information is typical. Contact Duracell for the latest information

6/08

900



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23
Format                          : application/pdf
Title                           : 9100_US.ai
Creator                         : Gary Shapiro
Create Date                     : 2008:06:19 15:33:10-04:00
Modify Date                     : 2008:07:01 11:57:50-04:00
Creator Tool                    : Adobe Illustrator CS3: pictwpstops filter 1.0
Metadata Date                   : 2008:07:01 11:57:50-04:00
Producer                        : Acrobat Distiller 8.1.0 (Macintosh)
Document ID                     : uuid:0ef55883-2bf9-d64b-bf25-852bdc525e54
Instance ID                     : uuid:54e72f6c-998b-cd46-abb0-4c64ac5328dc
Page Count                      : 2
Page Layout                     : TwoPageLeft
Author                          : Gary Shapiro
EXIF Metadata provided by EXIF.tools

Navigation menu